T1400. Standard Control Panel POWER. Voltage. kw e 415/24 400/23 380/22
|
|
- Randell Randall
- 5 years ago
- Views:
Transcription
1 T14 Engine ref. S12R-PTA Alternator ref. LSA 5.2 L7 Performance class G3 GENERAL CHARACTERISTICS Frequency (Hz) 5 Voltage (V) Optional control panel 4/23 Basic terminal block M8 Optional Control Panel TELYS Optional control panel APM82 Standard Control Panel POWER ESP Voltage DESCRIPTIVE Electronic governor Mechanically welded chassis with antivibration suspension 415/24 4/23 38/22 kw e kva PRP kw e kva DCC (*) kw e kva Standby Amps DIMENSIONS COMPACT VERSION Protective grille for fan and rotating parts (CE option) 2365 Exhaust compensators with flanges V charge alternator and starter Radiator for core temperature of 48/5 C max with mechanical fan Delivered with oil and coolant -3 C Manual for use and installation DIMENSIONS SOUNDPROOFED VERSION Commercial reference of the enclosure POWER DEFINITION PRP : Prime Power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO ESP : The standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO Overload is not allowed. *DCC : Data Center Continuous Power ratings apply to Data Center installations where a reliable utility power is available and comply with Uptime institute Tier III and IV requirements. At constant or varying load, the number of generator set operating hours is unlimited. A 1% overload capacity is available for one hour in twelve. Average load factor : 1%. Acoustic pressure in db(a) Sound power level guaranteed (Lwa) Acoustic pressure in db(a) TERMS OF USE According to the standard, the nominal power assigned by the genset is given for 25 C Air Intlet Temperature, of a barometric pressure of 1 kpa (1 m A.S.L), and 3 % relative humidity. For particular conditions in your installation, refer to the derating table. ASSOCIATED UNCERTAINTY For the generating sets used indoor, where the acoustic pressure levels depends on the installation conditions, it is not possible to specify the ambient noise level in the exploitation and maintenance instructions. You will also find in our exploitation and maintenance instructions a
2 warning concerning the air noise dangers and the need to implement appropriated preventive measures
3 T14 ENGINE CHARACTERISTICS GENERAL ENGINE DATA EXHAUST Engine brand MITSUBISHI Exhaust gas ESP 5Hz ( C) 492 Engine ref. S12R-PTA Exhaust gas ESP 5 Hz (L/s) 3916, Air inlet system Turbo Max. exhaust back pressure (mm H2O) 6 Cylinders configuration V Number of cylinders 12 FUEL Displacement (L) 49,3 11% load (L/h) 3, Charge Air coolant Air/Water DC 1% load (L/h) 271, Bore (mm) x Stroke (mm) 17, x 18, 75% load (L/h) 28, Compression ratio 14 : 1 5% load (L/h) 151, Speed (RPM) 15 Maximum fuel pump flow (L/h) 588, Pistons speed (m/s) 9, Maximum stand-by power at rated 122, RPM (kw) Frequency regulation, steady state (%) +/-.5% OIL Oil capacity (L) 18, BMEP (bar) 18,11 Min. oil pressure (bar) 2,5 Governor type Electronic Max. oil pressure (bar) 5,8 Oil consumption 1% load (L/h) 1, Oil sump capacity (L) 15, COOLING SYSTEM Radiator & Engine capacity (L) 3, Max water temperature ( C) 98, HEAT BALANCE Outlet water temperature ( C) 95 Heat rejection to exhaust (kw) 758 Fan power (kw) 3, Radiated heat to ambiant (kw) 78, Fan air flow w/o restriction (m3/s) Available restriction on air flow (mm H2O) Type of coolant 25,9 Haet rejection to coolant (kw) 649, 2, Glycol-Ethylene Thermostat modulating range HT ( C) AIR INTAKE Max. intake restriction (mm H2O) Intake air flow (L/s) , EMISSIONS Emission PM (mg/nm3) 5% O2 12 Emission CO (mg/nm3) 5% O2 59 Emission HC+NOx (g/kwh) Emission HC (mg/nm3) 5% O
4 T14 ALTERNATOR CHARACTERISTICS GENERAL DATA OTHER DATA Alternator ref. LSA 5.2 L7 Continuous Nominal Rating 4 C (kva) 135, Number of Phase Three phase Power factor (Cos Phi),8 Standby Rating 27 C (kva) Efficiencies 1% of load (%) 1485, 95,2 Altitude (m) to 1 Air flow (m3/s) 1,8 Overspeed (rpm) 225 Short circuit ratio (Kcc),344 Number of pole Capacity for maintaining short circuit at 3 ln for 1 s Insulation class 4 Direct axis synchro reactance unsaturated (Xd) (%) 364, Yes Quadra axis synchro reactance unsaturated (Xq) (%) T class (H/125 ), continuous 4 C H / 125 K T class, standby 27 C H / 163 K AVR Regulation Total Harmonic Distortion in no-load DHT (%) Total Harmonic Distortion, on load DHT (%) Wave form : NEMA=TIF Yes Wave form : CEI=FHT <2 Number of bearing 1 Coupling Voltage regulation at established rating (+/- %) Recovery time (Delta U = 2% transcient) (ms) Indication of protection Direct Technology Without collar or brush H <3.5 <3.5 <5 Open circuit time constant (T'do) (ms) 375, Direct axis transcient reactance saturated (X'd) (%) 17,4 Short circuit transcient time constant (T'd) (ms) Direct axis subtranscient reactance saturated (X''d) (%) Subtranscient time constant (T"d) (ms) Quadra axis subtranscient reactance saturated (X"q) (%) Subtranscient time constant (T"q) (ms) 18, 14,8 18, 15,5 18, Zero sequence reactance unsaturated (Xo) (%),5 5 IP 23 Negative sequence reactance saturated (X2) (%) 15,21 Armature time constant (Ta) (ms) 27, No load excitation current (io) (A),85 Full load excitation current (ic) (A) 3,49 Full load excitation voltage (uc) (V) Engine start (Delta U = 2% perm. or 5% trans.) (kva) Transcient dip (4/4 load) - PF :,8 AR (%) 43,8 No load losses (W) Heat rejection (W) Unbalanced load acceptance ratio (%) 2766,72 12, 15287, ,8 9 5 DIMENSIONS CONTAINER ISO 2 Commercial reference of the enclosure Acoustic pressure in db(a) Sound power level guaranteed (Lwa) Acoustic pressure in db(a) CONTAINER CIR 2 Ssi ISO2 Si Commercial reference of the enclosure Acoustic pressure in db(a) Sound power level guaranteed (Lwa) Acoustic pressure in db(a) CIR2 SSi
5 T14 CONTROL PANEL Basic terminal block M8, transfer of information The control unit can be used as a basic terminal block for connecting a control box. The M8 is a dual-function control unit. It can be used as a basic terminal block for connecting a control box and as an instrument panel with a direct read facility, with displays giving a global view of your generating set's basic parameters. Offers the following functions: emergency stop button, customer connection terminal block, CE. Offers the following functions: Engine parameters: tachometer, working hours counter, coolant temperature indicator, oil pressure indicator, emergency stop button, customer connection terminal block, CE
6 TELYS, ergonomic and user-friendly APM82 dedicated to power plant management The highly versatile TELYS control unit is complex yet accessible, thanks to the particular attention paid to optimising its ergonomics and ease of use. With its large display screen, buttons and scroll wheel, it places the accent on simplicity and communication. The new APM82 command/control system is specifically designed for operating and monitoring power plants for markets including hospitals, data centres, banks, the oil and gas sector, industries, IPP, rental and mining. This unit is available as standard on all generating sets from 275 Kva designed for coupling. It is optional on the rest of our range. The Human Machine Interface, designed in collaboration with a company specialising in interface design, facilitates operations with a large 1% touch screen. The preconfigured system for power plant applications features a brand new customisation function which complies with the international standard IEC New communication functions (PLC and regulation), improve the high level of equipment availability in the installation. The TELYS offers the following functions: Electrical measurements: voltmeter, frequency meter, ammeter. Engine parameters: working hours counter, oil pressure, coolant temperature, fuel level, engine speed, battery voltage. Alarms and faults: oil pressure, coolant temperature, failure to start, overspeed, alternator min./max., battery voltage min./max., emergency stop, fuel level. Ergonomics: wheel for navigating around the various menus. Communication: remote control and operation software, USB connections, PC connection. Advantages: Dedicated to power plant management. Specially researched ergonomics. High level of equipment availability. Modularity and long service life guaranteed. Making it easy to extend the installation For more information, please refer to the sales documentation. For more information on the product and its options, please refer to the sales documentation
V700C2. Optional Control Panel POWER. Voltage. DIMENSIONS COMPACT VERSION 24 V charge alternator and starter
VC2 Engine ref. TWD1643GE Alternator ref. LSA 49.3 S4 Performance class G3 GENERAL CHARACTERISTICS Frequency (Hz) 50 Voltage (V) 400/230 Standard Control Panel TELYS Optional control panel APM802 Basic
More informationX1100C GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE
Engine ref. Alternator ref. Performance class 16V2000G65E LSA 49.1 L11 G3 GENERAL CHARACTERISTICS Frequency (Hz) 50 Voltage (V) 400/230 Optional control panel M80 Optional Control Panel TELYS Optional
More informationX800 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.
Engine ref. Alternator ref. Performance class 12V2000G65RF KH02850T G3 GENERAL CHARACTERISTICS Frequency (Hz) 50 Hz Voltage (V) 400/230 Standard Control Panel NA Optional control panel M80 Optional Control
More informationOptional control panel POWER. Voltage
Engine ref. P126TI Alternator ref. AT0T Performance class G3 GENERAL CHARACTERISTICS Frequency (Hz) 50 Voltage (V) 400/230 Standard Control Panel APM303 Optional control panel TELYS Optional Control Panel
More informationV500UC2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.
Engine ref. Alternator ref. Performance class TAD1641GE AT02450T G3 GENERAL CHARACTERISTICS Frequency (Hz) 60 Voltage (V) 480/277 Standard Control Panel TELYS Optional control panel APM802 POWER Voltage
More informationKV550C2. Optional control panel POWER
Engine ref. Alternator ref. Performance class TAD1641GE AT02450T G3 DESCRIPTIVE Kohler Co. Provides one-source responsibility for the generating system and accessories. The generator set and its components
More informationV275C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.
Engine ref. Alternator ref. Performance class TAD734GE KH01421T G3 GENERAL CHARACTERISTICS Frequency (Hz) 50 Hz Voltage (V) 400/230 Standard Control Panel APM403 Optional control panel APM802 Optional
More informationV550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.
Engine ref. Alternator ref. Performance class TAD1641GE KH02450T G3 GENERAL CHARACTERISTICS Frequency (Hz) 50 Hz Voltage (V) 400/230 Standard Control Panel APM403 Optional control panel APM802 Optional
More informationV550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.
Engine ref. Alternator ref. Performance class TAD1641GE LSA 47.2 M7 G3 GENERAL CHARACTERISTICS Frequency (Hz) 50 Voltage (V) 400/230 Standard Control Panel TELYS Optional control panel APM802 POWER Voltage
More informationD330 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.
Engine ref. Alternator ref. Performance class P126TI-II AT02260T G3 GENERAL CHARACTERISTICS Frequency (Hz) 50 Voltage (V) 400/230 Standard Control Panel APM303 Optional control panel TELYS Optional Control
More informationV550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.
Engine ref. Alternator ref. Performance class TAD1641GE KH02450T G3 GENERAL CHARACTERISTICS Frequency (Hz) 50 Hz Voltage (V) 400/230 Standard Control Panel APM403 Optional control panel APM802 Optional
More informationKX1100. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel Optional control panel POWER
Engine type Alternator type Performance class GENERAL CHARACTERISTICS Frequency (Hz) Voltage (V) Standard control panel 16V2000G65F KH03542T G3 50 400/230 M80 DEC4000 APM802 POWER Voltage ESP PRP kwe kva
More informationV500UC2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.
Engine ref. Alternator ref. Performance class TAD1641GE KH02450T G3 DESCRIPTIVE GENERAL CHARACTERISTICS Frequency (Hz) 60 Hz Voltage (V) 480/277 Standard Control Panel APM403 Optional control panel APM802
More informationKV550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.
Engine ref. Alternator ref. Performance class TAD1641GE KH02450T G3 DESCRIPTIVE Kohler Co. Provides one-source responsibility for the generating system and accessories. The generator set and its components
More informationKV500C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION. Soundproof version with CE directive (CN09 option) Type soundproofing
Engine ref. Alternator ref. Performance class TAD1345GE KH02070T G3 GENERAL CHARACTERISTICS Frequency (Hz) 50 Hz Voltage (V) 400/230 Standard Control Panel APM403 Optional control panel APM802 Optional
More informationOptional Control Panel POWER
Engine ref. Alternator ref. Performance class KDW1003 AT00260T G2 GENERAL CHARACTERISTICS Frequency (Hz) 50 Voltage (V) 400/230 Standard Control Panel Optional control panel Optional Control Panel APM303
More informationK12. Optional Control Panel POWER K12
Engine ref. Alternator ref. Performance class KDW1404 AT00350T G2 GENERAL CHARACTERISTICS Frequency (Hz) 50 Voltage (V) 400/230 Standard Control Panel Optional control panel Optional Control Panel APM303
More informationT16K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.
Engine ref. Alternator ref. Performance class S4L2-SD KH00470T G2 GENERAL CHARACTERISTICS Frequency (Hz) 50 Hz Voltage (V) 400/230 Standard Control Panel APM303 Optional control panel TELYS Optional Control
More informationJ60U GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.
Engine ref. Alternator ref. Performance class 4045TF120 KH00771T G3 GENERAL CHARACTERISTICS Frequency (Hz) 60 Hz Voltage (V) 480/277 Standard Control Panel APM303 Optional control panel TELYS Optional
More informationJ220K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.
Engine ref. Alternator ref. Performance class 6068HSG22 KH01220T G2 GENERAL CHARACTERISTICS Frequency (Hz) 50 Hz Voltage (V) 400/230 Standard Control Panel APM303 Optional control panel TELYS Optional
More informationK20UM POWER 240 MONO-BI
Engine ref. Alternator ref. Performance class KDI1903M KH00630T G2 GENERAL CHARACTERISTICS Frequency (Hz) Voltage (V) Standard Control Panel Optional control panel Optional Control Panel 60 Hz 240 single
More informationJ80UC3 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.
Engine ref. Alternator ref. Performance class 4045HFS82 AT00971T G3 GENERAL CHARACTERISTICS Frequency (Hz) 60 Voltage (V) 480/277 Standard Control Panel APM303 Optional control panel TELYS POWER Voltage
More informationJ200UC3 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.
Engine ref. Alternator ref. Performance class 6068HFS89 AT01310T G3 GENERAL CHARACTERISTICS Frequency (Hz) 60 Voltage (V) 480/277 Standard Control Panel APM303 Optional control panel TELYS POWER Voltage
More informationKK44 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.
Engine ref. Alternator ref. Performance class KDI2504TM-40 KH00500T G2 GENERAL CHARACTERISTICS Frequency (Hz) 50 Hz Voltage (V) 400/230 Standard Control Panel APM303 Optional control panel DEC 4000 Optional
More informationKV550C2. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel Optional control panel POWER
Engine type Alternator type Performance class TAD1641GE KH02450T G3 GENERAL CHARACTERISTICS Frequency (Hz) Voltage (V) Standard control panel 50 400/230 APM403 APM802 M80 DEC4000 POWER Voltage ESP PRP
More informationK28H GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.
Engine ref. Alternator ref. Performance class KDW1603-H AT00460T G2 GENERAL CHARACTERISTICS Frequency (Hz) 50 Voltage (V) 400/230 Standard Control Panel APM303 Optional control panel TELYS POWER Voltage
More informationKM2500. Engine type Alternator type Performance class
Engine type Alternator type Performance class S16R2PTAW KH05793T G3 GENERAL CHARACTERISTICS DESCRIPTIVE Kohler Co. Provides onesource responsibility for the generating system and accessories The generator
More informationJ66K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.
Engine ref. Alternator ref. Performance class 4045TF120 KH00771T G3 GENERAL CHARACTERISTICS Frequency (Hz) 50 Hz Voltage (V) 400/230 Standard Control Panel APM303 Optional control panel APM403 Optional
More informationJ165K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.
Engine ref. Alternator ref. Performance class 6068HF120-153 KH01340T G3 GENERAL CHARACTERISTICS Frequency (Hz) 50 Hz Voltage (V) 400/230 Standard Control Panel APM303 Optional control panel APM403 Optional
More informationK17M POWER 240 MONO 230 MONO 220 MONO
Engine ref. Alternator ref. Performance class GENERAL CHARACTERISTICS Frequency (Hz) Voltage (V) Standard Control Panel Optional control panel Optional Control Panel Optional control panel KDI1903M KH00630T
More informationKM44. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel POWER
Engine type Alternator type Performance class S4S-DT AT00500T G2 GENERAL CHARACTERISTICS Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel POWER ESP PRP Voltage
More informationKV500UC2. Frequency (Hz) Voltage (V) Standard Control Panel Optional control panel Optional control panel Optional control panel POWER
Engine type Alternator type Performance class TAD1641GE KH02450T G3 GENERAL CHARACTERISTICS Frequency (Hz) Voltage (V) Standard Control Panel 60 480/277 APM403 APM802 M80 DEC4000 POWER Voltage ESP PRP
More informationKH275. Frequency (Hz) Optional control panel POWER. Voltage
KH Engine type P126TI Alternator type KH0T Performance class G3 GENERAL CHARACTERISTICS Frequency (Hz) 50 Voltage (V) 400/230 Standard control panel APM303 APM802 M80 APM403 POWER Voltage ESP PRP Standby
More informationKM33. Frequency (Hz) Voltage (V) Standard control Panel Optional control panel Optional control Panel POWER
Engine type Alternator type Performance class GENERAL CHARACTERISTICS Frequency (Hz) Voltage (V) Standard control Panel Optional control panel Optional control Panel POWER ESP PRP Voltage kwe kva kwe kva
More informationK26M POWER 240 MONO 230 MONO 220 MONO
Engine ref. Alternator ref. Performance class GENERAL CHARACTERISTICS Frequency (Hz) Voltage (V) Standard Control Panel Optional control panel KDI2504TM-30 KH00500T G3 50 Hz 230 single phase APM303 APM403
More informationENGINE CHARACTERISTICS
Engine type Alternator type Performance class KDW1003 KH00260T G2 DESCRIPTIVE Kohler Co. Provides onesource responsibility for the generating system and accessories The generator set and its components
More informationKD165. Engine type Alternator type Performance class. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel
Engine type Alternator type Performance class 6068HF120153 KH01340T G3 GENERAL CHARACTERISTICS Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel POWER ESP
More informationV550C2 GENERAL CHARACTERISTICS POWERS DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.
Engine ref. Alternator ref. Performance class TAD1641GE LSA 47.2 M7 G3 GENERAL CHARACTERISTICS Frequency (Hz) 50 Voltage (V) 400/230 Standard Control Panel TELYS Optional control panel KERYS POWERS Voltage
More informationGZ25 POWER. Fuel System 50 Hz:
Engine ref. Alternator ref. GMC430-27 4P4 GENERAL CHARACTERISTICS Frequency (Hz) 50 Voltage (V) 400/230 Standard Control Panel DEC3000 POWER Voltage ESP PRP kwe kva kwe kva Standby Amps 400/230 20 25 -
More informationEngine type Alternator type Canopy Type GENERAL CHARACTERISTICS
DESCRIPTIVE Stage 3a engine Leroy-Somer AREP (TS26-S004) Alternator Four-pole circuit breaker Connection terminal box rental type Containment fuel tank and large autonomy Forks and frame protection pads
More informationGZ50 POWER. Fuel System 50 Hz:
Engine ref. Alternator ref. GMC850 KH00701T GENERAL CHARACTERISTICS Frequency (Hz) 50 Hz Voltage (V) 400/230 Standard Control Panel DEC 3000 POWER Voltage ESP PRP kwe kva kwe kva Standby Amps 400/230 40
More informationEngine type Alternator type Canopy Type GENERAL CHARACTERISTICS
DESCRIPTIVE Stage 3a engine Leroy-Somer AREP (TS26-S004) Alternator Four-pole circuit breaker Connection terminal box rental type Containment fuel tank and large autonomy Engine type Alternator type Canopy
More informationGZ40 POWER. Fuel System 50 Hz:
Engine ref. Alternator ref. GMC643-36 4P5 GENERAL CHARACTERISTICS Frequency (Hz) 50 Voltage (V) 400/230 Standard Control Panel DEC3000 POWER Voltage ESP PRP kwe kva kwe kva Standby Amps 400/230 28 35 25
More informationType Dimensions Weight Tank Length: 6400mm 7836kg [17275lbs] [252in] Net 930 L 9020kg [19886lbs] Heigth: 2721mm Gross [107in]
Electronic governor X715K STANDARD FEATURES Mechanically welded chassis with antivibration suspension Radiator for wiring T of 40 C [104 F] max with mechanical fan Exhaust outlet with flexible and flanges
More informationType Dimensions Weight Tank Length: 6400mm 8709kg [19200lbs] [252in] Net 930 L 10000kg [22046lbs] Heigth: 2721mm Gross [107in]
Electronic governor X1000K STANDARD FEATURES Mechanically welded chassis with antivibration suspension Radiator for wiring T of 40 C [104 F] max with mechanical fan Exhaust outlet with flexible and flanges
More informationIndustrial Diesel Generator Set KD1650-E 50 Hz - Emission Optimized EPA Tier 2 Compliant
RATINGS 400V - 50 Hz Standby kva 1650 KWe 1320 Prime kva 1500 KWe 1200 Benefits & features SDMO premium quality SDMO provides one source responsibility for the generating system and accessories The generator
More informationIndustrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized
RATINGS 480 V - 60 Hz Standby kva 2187.50 KWe 1750 Prime kva 1989 KWe 1591 Benefits & features premium quality provides one source responsibility for the generating system and accessories The generator
More informationIndustrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized
RATINGS 400 V - 50 Hz Standby kva 1100 KWe 880 Prime kva 1000 KWe 800 Benefits & features premium quality provides one source responsibility for the generating system and accessories The generator set,
More informationIndustrial Diesel Generator Set KD2500-F 50 Hz Fuel Consumption Optimized
RATINGS 400 V - 50 Hz Standby kva 2500 KWe 2000 Prime kva 2273 KWe 1818 Benefits & features SDMO premium quality SDMO provides one source responsibility for the generating system and accessories The generator
More informationIndustrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized
RATINGS 400 V - 50 Hz Standby kva 1100 KWe 880 Prime kva 1000 KWe 800 Benefits & features SDMO premium quality SDMO provides one source responsibility for the generating system and accessories The generator
More informationIndustrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized
RATINGS 400 V - 50 Hz Standby kva 2250 KWe 1800 Prime kva 2045 KWe 1636 Benefits & features premium quality provides one source responsibility for the generating system and accessories The generator set,
More informationIndustrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified
RATINGS 480 V - 60 Hz Standby kva 1562.50 KWe 1250 Prime kva 1420 KWe 1136 Benefits & features premium quality provides one source responsibility for the generating system and accessories The generator
More informationTERM OF USE Standard reference conditions ESP/PRP 27 C /40 C Air Intlet Temp, 1000 m/1000 m m A.S.L. 60 % relative humidity.
V200U STANDARD FEATURES 200 KW / 250 KVA FULLY PACKAGED GENERATOR SET INCLUDES: VOLVO Heavy duty diesel engine, 4 stroke, 1800rpm, Turbo LEROY SOMER brushless alternator. IP23 protection, Insulation
More informationTERM OF USE Standard reference conditions ESP/PRP 25 C /25 C Air Intlet Temp, 1000 m/1000 m m A.S.L. 60 % relative humidity.
J60UC3 60KW GENERATOR 60 KW / 75 KVA DIESEL GENERATOR SET, FULLY PACKAGED: JOHN DEERE Heavy duty diesel engine, 4 stroke, 1800rpm, Turbo LEROY SOMER brushless alternator. IP23 protection, Insulation
More informationIndustrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized
RATINGS 400 V - 50 Hz Standby kva 3500 KWe 2800 Prime kva 3182 KWe 2546 Benefits & features premium quality provides one source responsibility for the generating system and accessories The generator set,
More informationEngine JOHN DEERE, 4045HFS83, U.S. EPA Tier 3 Alternator LEROY SOMER, LSA442VS45 <Debut> 100KW GENERATOR
J100UC3 Engine JOHN DEERE, 4045HFS83, U.S. EPA Tier 3 Alternator LEROY SOMER, LSA442VS45 100KW GENERATOR 100 KW / 125 KVA DIESEL GENERATOR SET, FULLY PACKAGED: JOHN DEERE Heavy duty diesel engine,
More informationIndustrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized
RATINGS 400 V - 50 Hz Standby kva 3300 KWe 2640 Prime kva 3000 KWe 2400 Benefits & features premium quality provides one source responsibility for the generating system and accessories The generator set,
More informationENGINE DATA. 205L/s [434cfm] 565 C [1049 F] 750mm CE [30in. WG
R90K DIESEL GENSET MODEL R90K Stand-by Power @ Hz Prime Power @ Hz 70 kw / 88 kva 64 kw / 80 kva Standard Features General features : Engine (JOHN DEERE, 4045TF220) Radiator C [122 F] C max. T air inlet
More informationDIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva
R110K MODEL Stand-by Power @ 50Hz Prime Power @ 50Hz DIESEL GENSET R110K 88 kw / 110 kva 80 kw / 100 kva Standard Features General features : Engine (JOHN DEERE, 4045HF120) Radiator 50 C [122 F] C max.
More informationDIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva
R33 MODEL Stand-by Power @ 50Hz Prime Power @ 50Hz DIESEL GENSET R33 26kW / 33 kva 24 kw / 30 kva Standard Features General features : Engine (JOHN DEERE, 3029DF120) Radiator 50 C [122 F] C max. T air
More informationDIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva
T9KM Standard Features MODEL Stand-by Power @ 50Hz Prime Power @ 50Hz DIESEL GENSET T9KM 9kW / 9 kva 8 kw / 8 kva General features : Engine (MITSUBISHI, S3L2.SD ) Charge alternator 12 V, Governor:Meca
More informationPrime 60Hz 455 kw / 568 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva
V500UC MODEL DIESEL GENSET V500UC Stand-by Power @ 60Hz 500kW / 625 kva Prime Power @ 60Hz 455 kw / 568 kva Standard Features General features : Engine (VOLVO, TAD1641GE ) Engine EPA Carb Charge alternator
More informationDIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva
J440K Standard Features MODEL Stand-by Power @ 50Hz Prime Power @ 50Hz DIESEL GENSET J440K 352kW / 440 kva 320 kw / 400 kva General features : Engine (JOHN DEERE, 6125HF070-387 ) Charge alternator 24 V,
More informationDIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva
J200K Standard Features MODEL Stand-by Power @ 50Hz Prime Power @ 50Hz DIESEL GENSET J200K 160kW / 200 kva 145 kw / 182 kva General features : Engine (JOHN DEERE, 6068HF120-183 ) Charge alternator 12 V,
More informationDIESEL GENSET. Prime Hz 16 kw / 20 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva
TM20K MODEL DIESEL GENSET TM20K Stand-by Power @ 50Hz 18kW / 22 kva Prime Power @ Hz 16 kw / 20 kva Standard Features General features : Engine (MITSUBISHI, S4Q2.SD ) Charge alternator 12 V, Governor:Meca/Mechanical
More informationPrime Hz 400 kw / 500 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva
GS500K MODEL DIESEL GENSET GS500K Stand-by Power @ 50Hz 440kW / 550 kva Prime Power @ Hz 400 kw / 500 kva Standard Features General features : Engine (VOLVO, TAD1631GE ) Charge alternator 24 V, Governor:Electronic
More informationPrime 60Hz 155 kw / 193 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva
J170UC MODEL DIESEL GENSET J170UC Stand-by Power @ 60Hz 170kW / 213 kva Prime Power @ 60Hz 155 kw / 193 kva Standard Features General features : Engine (JOHN DEERE, 6068HF275-187 ) Engine EPA Carb Charge
More informationPrime 60Hz 273 kw / 341 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva
V300UC MODEL DIESEL GENSET V300UC Stand-by Power @ 60Hz 300kW / 375 kva Prime Power @ 60Hz 273 kw / 341 kva Standard Features General features : Engine (VOLVO, TAD941GE ) Engine EPA Carb Charge alternator
More informationDIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva
J33 Standard Features MODEL Stand-by Power @ 50Hz Prime Power @ 50Hz DIESEL GENSET J33 26kW / 33 kva 24 kw / 30 kva General features : Engine (JOHN DEERE, 3029DF120 ) Charge alternator 12 V, Governor:Meca
More informationDIESEL GENSET. Prime 60Hz 36 kw / 45 kva
J40UC MODEL DIESEL GENSET J40UC Stand-by Power @ 60Hz 40kW / 50 kva Prime Power @ 60Hz 36 kw / 45 kva Standard Features General features : Engine (JOHN DEERE, 3029TF270 ) Engine EPA Carb Charge alternator
More informationPrime 60Hz 18 kw / 18 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings Prime Ratings kw/kva 240MONO / / 18
T20UCM MODEL DIESEL GENSET T20UCM Stand-by Power @ 60Hz 20kW / 20 kva Prime Power @ 60Hz 18 kw / 18 kva Standard Features General features : Engine (MITSUBISHI, S4Q2.Y262SD ) Engine EPA Carb Charge alternator
More informationDIESEL GENSET. Prime 60Hz 91 kw / 114 kva
J100U MODEL DIESEL GENSET J100U Stand-by Power @ 60Hz 100kW / 125 kva Prime Power @ 60Hz 91 kw / 114 kva Standard Features General features : Engine (JOHN DEERE, 4045HF120 ) Charge alternator 12 V, Governor:Meca
More informationVoltage HZ Phase P.F Standby Amps Standby Ratings kw/kva
JS275UC MODEL Stand-by Power @ 60Hz Prime Power @ 60Hz DIESEL GENSET JS275UC 275kW / 344 kva 250 kw / 313 kva Standard Features General features : Engine (JOHN DEERE, 6081HF070-318 ) Engine EPA Carb Charge
More informationDIESEL GENSET. Prime 60Hz 55 kw / 68 kva
J60UC MODEL DIESEL GENSET J60UC Stand-by Power @ 60Hz 60kW / 75 kva Prime Power @ 60Hz 55 kw / 68 kva Standard Features General features : Engine (JOHN DEERE, 4045TF270 ) Engine EPA Carb Charge alternator
More informationTM20UCM MODEL. Standard Features. Generator Ratings. Conditions of sale. Prime Hz 18 kw / 18 kva. General features :
TM20UCM MODEL Standard Features DIESEL GENSET TM20UCM Stand-by Power @ 60Hz 20kW / 20 kva Prime Power @ Hz 18 kw / 18 kva General features : Engine (MITSUBISHI, S4Q2.Y262SD ) Engine EPA Carb Charge alternator
More informationVoltage HZ Phase P.F Standby Amps Standby Ratings kw/kva
JS200UC MODEL Stand-by Power @ 60Hz Prime Power @ 60Hz DIESEL GENSET JS200UC 200kW / 250 kva 182 kw / 227 kva Standard Features General features : Engine (JOHN DEERE, 6068HF475 ) Engine EPA Carb Charge
More informationVoltage HZ Phase P.F Standby Amps Standby Ratings kw/kva. Prime Ratings kw/kva 240MONO / 10 9 / 9
TM11UCM MODEL Stand-by Power @ 60Hz Prime Power @ 60Hz DIESEL GENSET TM11UCM 10kW / 10 kva 9 kw / 9 kva Standard Features General features : Engine (MITSUBISHI, S3L2.W262SD ) Engine EPA Carb Charge alternator
More informationRéf GB / e ALTERNATORS. LSA Pole. Electrical and mechanical data
Réf. 3303 GB - 2.33 / e - 04.02 35 30 25 20 15 10 ALTERNATORS LSA 50.1-4 Pole Electrical and mechanical data ELECTRICAL DATA ALTERNATORS LSA 50.1-4P 50 Hz - 1500 r.p.m. Insulation class H Excitation system
More informationUSP&E Cummins Series Diesel Generator Set
Powered by Cummins KTAA19-G6A 600KVA at 50Hz, 400V USP&E Cummins Series Diesel Generator Set Genset Model U530-50 Prime Power(50HZ) 480KW / 600KVA 528KW / 660KVA Standby Power(50HZ) Frequency/Speed Voltage
More informationUSP&E Cummins Series Diesel Generator Set
Powered by Cummins QSK19-G3 650KVA at 50Hz, 400V USP&E Cummins Series Diesel Generator Set Genset Model U570-50 Prime Power(50HZ) 520KW / 650KVA Standby Power(50HZ) 572KW / 715KVA Frequency/Speed 50Hz/1500rpm
More informationUSP&ECummins Series Diesel Generator Set
Powered by Cummins KTA19-G3 565KVA at 60Hz, 480V USP&ECummins Series Diesel Generator Set Genset Model U450-60 Prime Power(60HZ) Standby Power(60HZ) Frequency/Speed Voltage Phases Manufacturer 410KW /
More informationLow Voltage Alternators - 4 pole LSA 44.3
LSA 44.3 70 to 150 kva - 50 Hz / 88 to 188 kva - 60 Hz Electrical and mechanical data Specially adapted to applications The LSA 44.3 alternator is designed to be suitable for typical generator applications,
More informationEngine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me
WGP-C30/S CUMMINS Series Rotate speed governor: Mechanical governor Excitation system: Self excited, SHUNT A.V.R model: AS480 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed
More informationUSP&E Cummins Series Diesel Generator Set
USP&E GLOBAL LLC Powered by Cummins KTA38-G9 1125KVA at 50Hz, 400V USP&E Cummins Series Diesel Generator Set Genset Model U1000 Prime Power(50HZ) 900KW / 1125KVA Standby Power(50HZ) 990KW / 1406KVA Frequency/Speed
More informationUSP&E Cummins Series Diesel Generator Set
Powered by Cummins KTA50-G3 1250KVA at 50Hz, 400V USP&E Cummins Series Diesel Generator Set Genset Model U1100-50 Prime Power(50HZ) 1000KW / 1250KVA Standby Power(50HZ) 1100KW / 1375KVA Frequency/Speed
More informationVoltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00
3 Phase Ratings, 50 Hz, PF 0,8 Rating (ESP) Prime Rating (PRP) Voltage kva kw kva kw Amp 400/230 200,00 160,00 180,00 144,00 259,00 Rating (ESP): Prime Rating (PRP): Applicable for supplying power to varying
More informationThis generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.
This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product
More informationP 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.
This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product
More information50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant
D I E S E L G E N E R A T I N G S E T GEP33-1 (3-Phase) 50 HZ STANDBY PRIME 60 HZ STANDBY PRIME 33.0 kva / 26.4 kw 30.0 kva / 24.0 kw 37.5 kva / 30.0 kw 33.8 kva / 27.0 kw FEATURES GENERATING SET l Complete
More informationLSA 52.3 Low Voltage Alternators - 4 pole
LSA 52.3 Low Voltage Alternators - 4 pole 1860 to 2500 kva - 50 Hz / 2230 to 3000 kva - 60 Hz Electrical and mechanical data Specially adapted to applications The LSA 52.3 alternator is designed to be
More informationVoltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00
cummins diesel 0 kva Phase Ratings, 0 Hz, PF 0,8 Rating (ESP) Prime Rating (PRP) Voltage kva kw kva kw Amp 00/0 0,00 88,00 00,00 80,00,00 Rating (ESP): Prime Rating (PRP): Applicable for supplying power
More informationCUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00
CUMMINS 30KVA 3 Phase Ratings, 50 Hz, PF 0,8 Rating (ESP) Prime Rating (PRP) Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00 Rating (ESP): Prime Rating (PRP): Applicable for supplying power
More information50 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant
D I E S E L G E N E R A T I N G S E T GEP30-2 (3-Phase) 50 HZ STANDBY PRIME 30.0 kva / 24.0 kw 27.0 kva / 21.6 kw FEATURES GENERATING SET l Complete system designed and built at ISO9001 certified facility
More information50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant
D I E S E L G E N E R A T I N G S E T GEP65-5 (3-Phase) 50 HZ STANDBY PRIME 60 HZ STANDBY PRIME 65.0 kva / 52.0 kw 60.0 kva / 48.0 kw 75.0 kva / 60.0 kw 68.8 kva / 55.0 kw FEATURES GENERATING SET l Complete
More informationStandby Power(60Hz) Prime Power(60Hz) 1000KW / 1250KVA 900KW / 1125KVA. Standard Features
MODEL Standby Power(60Hz) Prime Power(60Hz) 1000KW / 1250KVA 900KW / 1125KVA Standard Features General Features: Engine (CCEC Cummins KTA38-G4) Radiator 40 O C max, fans are driven by belt, with safety
More information50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded
D I E S E L G E N E R A T I N G S E T GEP88-1 (3-Phase) 50 HZ STANDBY PRIME 60 HZ STANDBY PRIME 88.0 kva / 70.4 kw 80.0 kva / 64.0 kw 100 kva / 80.0 kw 90.0 kva / 72.0 kw FEATURES GENERATING SET l Complete
More informationEnclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00
This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed
More informationDIESEL GENERATOR SET MTU 16V4000 DS2500
DIESEL GENERATOR SET MTU 16V4000 DS2500 380V 11 kv/50 Hz/Data Center Continuous Power/TA-Luft Optimized MTU 16V4000G63/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary.
More information50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes
D I E S E L G E N E R A T O R S E T GEP550-2 (3-Phase) 50 HZ STANDBY PRIME 550 kva / 440 kw 500 kva / 400 kw FEATURES GENERATOR SET l Complete system designed and built at ISO9001 certified facility l
More informationYOUR POWER PARTNER. Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw 400/ ,
INTRODUCTION Water cooled, Diesel engine Radiator with mechanical fan Protective grille for rotating and hot parts Electric starter and charge alternator Starting battery (with lead acid) including rack
More information