Installation Instructions

Size: px
Start display at page:

Download "Installation Instructions"

Transcription

1 Installation Instructions SELECTRONIC PROXIMITY DUAL FLUSH TOILET FLUSH VALVE. /. GPF,.8/. GPF Certified to comply with ASME A.9.M 00 AS America, Inc. M90 REV.. Exposed Flushometer for -/" Top Spud Bowls MODEL NUMBERS This flushometer valve is intended to be used with listed/certified.gpf /.gpf dual flush bowls only. CLOG RESISTANT Self-cleaning piston valve prevents clogging and reduces maintenance. ONE SENSOR FITS ALL Only sensor for entire Selectronic line of faucets, urinals, and flush valves. Range can be adjusted manually or with optional remote control. Sensor Features Low Battery Indicator. TE TO INSTALLER: Please give this manual to the customer after installation. To learn more about American Standard Faucets visit our website at: or U.S. customer's us at: For Parts, Service, Warranty or other Assistance, please call (In Canada: ) (In Toronto Area only: )

2 Thank you for selecting American-Standard...the benchmark of fine quality for over 00 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. UNPACKING All American Standard Products Are Water Tested At Our Factory. Some Residual Water May Remain In The Valve During Shipping.. Remove the Flush Valve items from the carton. The illustration below shows all items after they have been removed from the carton. Some items may be packaged partially assembled to other items. CARE INSTRUCTIONS:. Flush Valve Assembly. Down Tube and Vacuum Breaker. Spud Coupling Nut and Washers. Spud Flange. Sweat Solder Adapter. Cover Tube 7. Wall Escutcheon 8. Supply Stop 9. Installation Instructions DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH. DO T: DO T CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE. DO T REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE Installation Instructions SELECTRONIC PROXIMITY DUAL FLUSH TOILET FLUSH VALVE. /. GPF,.8/. GPF Certified to comply with ASME A.9.M 00 AS America, Inc. M90 REV.. Exposed Flushometer for -/" Top Spud Bowls MODEL NUMBERS This flushometer valve is intended to be used with listed/certified.gpf /.gpf dual flush bowls only. CLOG RESISTANT Self-cleaning piston valve prevents clogging and reduces maintenance. ONE SENSOR FITS ALL Only sensor for entire Selectronic line of faucets, urinals, and flush valves. Range can be adjusted manually or with optional remote control. Sensor Features Low Battery Indicator. TE TO INSTALLER: Please give this manual to the customer after installation. To learn more about American Standard Faucets visit our website at: or U.S. customer's us at: faucetsupport@americanstandard.com For Parts, Service, Warranty or other Assistance, please call (In Canada: ) (In Toronto Area only: ) M90 REV..

3 Fig. Roughing-in Dimensions MANUAL OVERRIDE BUTTON 9mm (-/) mm (-/8) *CRITICAL LEVEL 7mm (-7/8) *-C-L- mm (-/) -C-L- mm-mm (-/ TO -/) FOR -/" TOP SPUD FIXTURES SUPPLY DN mm ( I.P.S.) 09mm (-/8) DETECTION ZONE 00mm-800mm (-/ TO -/) FINISHED WALL 7mm (-/ MIN.) GENERAL DESCRIPTION: SELECTRONIC PROXIMITY TOILET FLUSH VALVE Exposed Flushometer for -/" Top Spud Fixtures Exclusive, self cleaning piston-type flush valve with proximity operation and manual override. Operates on DC (battery) power. Recommended operating pressure psi (flowing) to 80 psi (static). Can install left or right-handed. Detection Zone can also be adjusted manually, or with optional remote control. Right or Left Hand Installation See (Section ) for converting Flush Valve to Left Hand Installation. *Note: The Critical Line (-C-L-) on Vacuum Breaker must typically be " (mm) above fixture. Consult Codes for details. RECOMMENDED TOOLS; Fig. Fig Teflon Tape Flat Blade Screwdriver Adjustable Wrench Tape Measure Hacksaw Tubing Cutter File For Sweat Connection; Solder and Torch.mm Hex Wrench.mm Hex Wrench 0' PRIOR TO INSTALLATION Note: Prior to installing the Selectronic Flush Valve the following items must be installed.. Water Closet. Drain line. Water supply line IMPORTANT: All plumbing must be installed in accordance with applicable codes and regulations. Water supply lines must be sized to provide an adequate volume of water for each fixture. Flush all water lines prior to operation (See Step ). Dirt and debris can cause flush valve to run continuously. With the exception of Supply Stop Inlet, DO T use pipe sealant or plumbing grease on any valve component or coupling! Protect the chrome or special finish on the Flushometer. DO T USE toothed tools on finished surfaces to install or service these valves. Also see Care and Cleaning section of this manual. This product contains mechanical and/or electrical components that are subject to normal wear. These components should be checked on a regular basis and replaced as needed to maintain the valve s performance. M90 REV..

4 INSTALL THE SWEAT SOLDER ADAPTER; Fig. CAUTION Turn water supplies off before beginning Note: Install Optional Sweat Solder Adapter (Supplied) for copper pipe supply line. Fig.. Fig. FINISHED WALL A CENTER LINE OF FIXTURE SPUD. Measure the distance (A) from the finished wall to the center of the inlet spud on the fixture.. Cut the supply pipe -/" (A-B=C) shorter then the measurement taken in Step. File any rough edges off the end of the supply pipe. (A-B)= C FILE EDGES CLEAN B mm (-/). Clean the end of the supply pipe. Push the threaded Adapter on until it is seated against the internal stop. Sweat the Adapter to the pipe. ADAPTER SOLDER ADAPTER INSTALL COVER TUBE, WALL ESCUTCHEON and SUPPLY STOP; Fig.. Measure from finished wall to first thread of Adapter or threaded supply pipe (dimension X ). Cut COVER TUBE () to length (X). Apply Teflon Tape to the threaded end of the Adapter or supply pipe. Fig. a.. Push the COVER TUBE () into the WALL ESCUTCHEON (). Slide both onto the SUPPLY PIPE (). Fig. b.. Push the COVER TUBE () in to expose the threads of the supply pipe. Fig. c. With a wrench thread the SUPPLY STOP () onto the SUPPLY PIPE (). Align and tighten. Fig. c.. Pull COVER TUBE () against SUPPLY STOP () and push WALL ESCUTCHEON () against finished wall. INSTALL DOWN TUBE AND VACUUM BREAKER; Fig.. Place the SPUD FLANGE () over the spud on the Fixture. Fig. Fig. a Fig. b Fig. c Fig. X FINISHED WALL TEFLON TAPE X. Thread SPUD COUPLING NUT () onto Spud. Make sure SEAL WASHER () and FRICTION WASHER () are installed. Do not tighten fully.. Insert the DOWN TUBE () into the SPUD COUPLING NUT () and push it down. Note: If cutting Down Tube () to size, note that Critical Line (C/L) on Vacuum Breaker must typically be " (mm) above fixture. Consult Code for details. -/" TOP SPUD M90 REV..

5 FLUSH OUT SUPPLY LINES; Fig.. Remove COVER () from SUPPLY STOP ().. With a flat blade screwdriver open SUPPLY STOP ().. Turn on water supply to flush line of any debris or sediment.. Close SUPPLY STOP () and replace COVER (). Fig. REMOVE COVER COUNTER-CLOCKWISE OPENS CONTROL STOP CLOCKWISE CLOSES CONTROL STOP LEFT OR RIGHT HAND INSTALLATION; Fig. 7 The UNIT is shipped with the inlet flange on the right side. If needed, the orientation can be reversed by following the steps below.. Loosen SET SCREW () with.mm Hex Wrench () in back of top half of FLUSH VALVE (). Fig. 7a. Fig. 7. Rotate TOP () to the right and pull off. Fig. 7b.. Rotate bottom half of FLUSH VALVE () 80. Fig. 7b.. Replace TOP () and rotate until key engages than tighten SET SCREW (). Fig. 7c, 7d. Fig. 7a Fig. 7b 80 Fig. 7c KEY Fig. 7d M90 REV..

6 INSTALL FLUSH VALVE; Fig. 8a & 8b. As shown in Fig. 8a, insert the side INLET FLANGE () on the FLUSH VALVE () into the SUPPLY STOP (). Lubricate the INLET FLANGE O-RING () with water if necessary. Lightly tighten COUPLING NUT (). Fig. 8a. Important: Do not use lubricants (other than water) or any type of thread sealing paste or tape. Fig. 8a. Align the FLUSH VALVE () (Fig. 8b) directly above the DOWN TUBE (7) and VACUUM BREAKER COUPLING NUT (). Make sure that GASKET (0) is installed. Note: There is a +mm, -mm (+/, -/) tolerance for the mm (-/) dimension. Fig. 8b.. Pull the DOWN TUBE (7) up to meet the threaded FLUSH VALVE CONNECTION (8) and hand tighten the VACUUM BREAKER COUPLING NUT (). Align all components of the flush valve assembly. Fig. 8b. Fig. 8b mm,+mm, -mm (-/)(+/, -/). Lightly tighten the COUPLING NUT () connection first, then the VACUUM BREAKER COUPLING NUT () and finally the SPUD COUPLING NUT (9). Once alligned correctly, use a wrench to tighten couplings to make water tight connections. Fig. 8b ADJUST SUPPLY STOP; Fig. 9 IMPORTANT: To avoid overflowing, the SUPPLY STOP () must never be opened to the point where the flow from the valve exceeds the flow capacity of the fixture. The fixture must be able to handle a continuous flow in case of a flush valve failure After installation is complete, peel off the PROTECTIVE FILM () from the sensor. Standing to one side, block the sensor with your hand for 0 seconds. Remove your hand and listen for audible click from within the valve.. Remove COVER () from SUPPLY STOP ().Turn on water supply / turn to / turn(ccw) and test for leaks. Note: Unit may flush for approximately to 0 sec. when water is first turned on. If flow persists, turn water off and repeat step # above. Fig. 9 REMOVE COVER. Actuate the FLUSH VALVE: A) Cover sensor with hand for 0 seconds. TE: Stand outside of sensor detection aera. B) Remove hand from in front of the sensor; unit will flush in approximately seconds. COUNTER-CLOCKWISE OPENS CONTROL STOP. Adjust SUPPLY STOP () after each flush until the stated flush volume is achieved, no splashing occurs and the fixture is properly cleansed. CLOCKWISE CLOSES CONTROL STOP. When adjustment is complete, replace COVER () and tighten to ensure vandal-resistance. M90 REV..

7 8 HOW TO RETROFIT OUR VALVE; Fig. 0 (Replaces Industry Standard Manual and Electronic Valves) Note: In most Retrofits the wall escutcheon, supply stop, cover tube and vacuum breaker do not have to be replaced. If these items do need replacement they must be purchased separately or order the complete flush valve assembly from American Standard.. Remove COVER () from SUPPLY STOP () if installed. Fig. 0. Fig. 0 Fig. 0a Fig. 0b CLEAN CONNECTIONS. Turn water supply off. Fig. 0.. Loosen SPUD COUPLING NUT (). Unthread COUPLING NUT () and VACUUM BREAKER COUPLING NUT (). Remove FLUSH VALVE (). Fig. 0.. Clean all threaded connections before installing the new flush valve. Fig. 0a. Fig. Fig. a Fig. b. Refer to Sections, and 7 to complete the retrofit installation. Fig. 0b. 9 HOW TO CHANGE THE BATTERY; (purchased after May 0) Fig.. Loosen SET SCREW () with.mm Hex Wrench () in back of top half of FLUSH VALVE CAP (). Fig. a.. Rotate CAP () to the right and pull off. Fig. b.. Turn CAP () over and disconnect the SENSOR () from the BATTERY CABLE (). Remove the BATTERY HOLDER () with BATTERY (7). Fig. c.. Remove old BATTERY (7). Install the new BATTERY (8) making sure the shape of the BATTERY (8) follows the shape of the BATTERY HOLDER (). Fig. d.. Insert the BATTERY HOLDER () with BATTERY (8) into FLUSH VALVE CAP (). Make sure the flat side of the BATTERY HOLDER () is facing towards the back of the FLUSH VALVE CAP (). Reverse the above steps to assemble flush valve. Fig. d. Fig. c REMOVE OLD BATTERY 7 CR-P Fig. d CR-P 8 INSTALL NEW BATTERY Fig. 9a HOW TO CHANGE THE BATTERY; (purchased before June 0) Fig.. Remove CAP (). Refer to Step 9 above. Fig. a. Fig. a REMOVE OLD BATTERY 0 a Fig. b. Turn CAP () over and remove the two SCREWS (9). Remove the BATTERY COVER (0) to expose the battery (a). Fig. a.. Remove old BATTERY (a). Install the new BATTERY (7a) making sure the + & - are facing up towards the open end of the cover. Fig. b.. Replace the BATTERY COVER (0) reverse the above steps to assemble flush valve. 9 INSTALL NEW BATTERY 7a 0 M90 REV..

8 0 HOW TO SET DETECTION RANGE (If Required); (purchased after May 0) Fig. & Note: The detection distance is preset and is ideal for most installations. Should an adjustment be required follow the steps below. Fig. Fig. a Fig. b. Loosen SET SCREW () with.mm Hex Wrench () in back of top half of FLUSH VALVE (). Fig. a. VIEW A. Rotate CAP () to the right and pull off. Fig. b.. Turn CAP () over and disconnect SENSOR CABLE () from BATTERY HOLDER (). Fig. c.. Keeping hands away from the front of the sensor, reconnect the SENSOR CABLE () and quickly place the CAP () on the valve. Do not secure the CAP () at this time. Note: You have seconds after connecting cable to enter program code.. While the SENSOR CONTROL LED () is blinking slowly, place your hand to in. (0-0mm.) in front of the sensor. Fig. a.. When the LED () stops blinking and stays "ON", move your hand to the desired position from sensor (detection zone, -/" to ", 8 to 787mm ) and hold in place until the LED () begins to blink again. Fig. b. Note: Detection Zone is -/" to ", 8 to 787mm from sensor. Fig. c VIEW A 7. Once the SENSOR CONTROL LED () begins to blink again, remove your hand from the detection zone. When the flashing stops, the detection distance is set. 8. Replace and secure CAP () onto valve. 9. Actuate the FLUSH VALVE: A) Cover sensor with hand for 0 seconds. TE: Stand outside of sensor detection aera. B) Remove hand from in front of the sensor; unit will flush in approximately seconds. Fig. BLINKING LED " - " (0mm - 0mm DETECTION ZONE 8mm TO 787mm (-/ TO ) BLINKING LED Fig. a Fig. b 7 M90 REV..

9 0a HOW TO SET DETECTION RANGE (If Required) ; (purchased before June 0) Fig. & Note: The detection distance is preset and is ideal for most installations. Should an adjustment be required follow the steps below. Fig. Fig. a Fig. b. Loosen SET SCREW () with.mm Hex Wrench () in back of top half of FLUSH VALVE (). Fig. a.. Rotate CAP () to the right and pull off. Fig. b. VIEW A. Turn CAP () over and disconnect GREY SENSOR WIRE () from BATTERY COVER (). Fig. c.. Keeping hands away from the front of the sensor, reconnect the GREY SENSOR WIRE () and quickly place the CAP () on the valve. Do not secure the CAP () at this time. Note: You have seconds after connecting cable to enter program code.. While the SENSOR CONTROL LED () is blinking slowly, place your hand to in. (0-0mm.) in front of the sensor. Fig. a.. When the LED () stops blinking and stays "ON", move your hand to the desired position from sensor (detection zone, -/" to ", 8 to 787mm ) and hold in place until the LED () begins to blink again. Fig. b. Note: Detection Zone is -/" to ", 8 to 787mm from sensor. 7. Once the SENSOR CONTROL LED () begins to blink again, remove your hand from the detection zone. When the flashing stops, the detection distance is set. Fig. c VIEW A 8. Replace and secure CAP () onto valve. 9. Actuate the FLUSH VALVE: A) Cover sensor with hand for 0 seconds. TE: Stand outside of sensor detection aera. B) Remove hand from in front of the sensor; unit will flush in approximately seconds. Fig. BLINKING LED " - " (0mm - 0mm DETECTION ZONE 8mm TO 787mm (-/ TO ) BLINKING LED Fig. a Fig. b 8 M90 REV..

10 UNIT DOES T FLUSH AT ALL IS STOP VALVE OPEN? OPEN VALVE LOOK FOR REPEATED DOUBLE FLASH ON SENSOR INSTALL NEW BATTERY TRY MANUAL VALVE BUTTON; WILL THE UNIT FLUSH? REPLACE PISTON KIT INSTALL NEW BATTERY SEE STEP 0, page in manual DOES THE SENSOR FLASH FOR THE FIRST SECONDS? REPLACE SENSOR RETRY AUTOMATIC FLUSH; WAS IT SUCCESSFUL? REPLACE SOLEID KIT UNIT IS CONTINUOUSLY FLUSHING PUSH MANUAL FLUSH BUTTON; DOES IT RETURN?. COVER SENSOR FOR 0 SECONDS. UNCOVER SENSOR FOR 0 SECONDS. DOES THE UNIT STOP FLUSHING? MANUAL VALVE OBSTRUCTED. CLOSE STOP VALVE AND SERVICE RETRY AUTO FLUSH LOOK FOR REPEATED DOUBLE FLASH ON SENSOR INSTALL NEW BATTERY SEE STEP 0, page in manual TEST SENSOR. DISCONNECT GRAY FLAT WIRE FROM BATTERY COVER AND RE-CONNECT. SENSOR SHOULD FLASH FOR SECONDS. DOES IT FLASH? REPLACE SENSOR. CLOSE STOP VALVE,. REPLACE SOLEID KIT.. RE-ASSEMBLE AND INSTALL UNIT.. OPEN STOP VALVE. UNIT WILL ONLY FLUSH MANUALLY LOOK FOR REPEATED DOUBLE FLASH ON SENSOR. COVER SENSOR FOR 0 SECONDS. UNCOVER SENSOR FOR 0 SECONDS. BATTERY LOW; REPLACE BATTERY SEE STEP 0, page in manual RETRY AUTOMATIC FLUSH. DOES THE UNIT FLUSH? TEST SENSOR. DISCONNECT GRAY FLAT WIRE FROM BATTERY COVER AND RE-CONNECT. SENSOR SHOULD FLASH FOR SECONDS. DOES IT FLASH? REPLACE BATTERY SEE STEP 0, page in manual RETRY AUTOMATIC FLUSH. CLOSE STOP VALVE, REPLACE SOLEID KIT. RE-ASSEMBLE & INSTALL UNIT. OPEN STOP VALVE. TROUBLESHOOTING FLOW CHARTS HOT LINE FOR HELP For toll-free information and answers to your questions, call: (800) -90 Weekdays 8:00 a.m. to :00 p.m. EST IN MEXICO IN CANADA (TORONTO ) Weekdays 8:00 a.m. to 7:00 p.m. EST Product names listed herein are trademarks of AS America, Inc. 9 M90 REV..

Installation Instructions

Installation Instructions Installation Instructions SELECTRONIC DC POWERED PROXIMITY EXPOSED URINAL FLUSH VALVE 0., 0., 0. &.0 GPF Certified to comply with ASME A.9. 0 AS America, Inc. Exposed Flushometer for /" Top Spud Urinals

More information

Installation Instructions

Installation Instructions Installation Instructions SELECTRONIC PROXIMITY TOILET CONCEALED FLUSH VALVE. &. GPF Certified to comply with ASME A..M 00 AS America, Inc. Concealed Flushometer for -/" Top or Back Spud Bowls MODEL NUMBERS

More information

Installation Instructions

Installation Instructions Installation Instructions for /" top spud Urinals Certified to comply with: ASSE 07 ANSI/ASME A.9. ADA Compliant 0 AS America, Inc. MODEL NUMBERS 0.0 FOR TOP SPUD APPLICATIONS CLOG RESISTANT Self-cleaning

More information

Installation Instructions

Installation Instructions Installation Instructions SELECTRONIC EXPOSED TOILET FLUSH VALVE AC POWERED PROXIMITY.,.8,.6,.6/. &.8/. GPF Certified to comply with ASME A.9. 0 AS America, Inc. MODEL NUMBERS 6067. 6067. 6067.6 6067.7

More information

Installation Instructions

Installation Instructions Installation Instructions SELECTRONIC EXPOSED TOILET FLUSH VALVE AC POWERED PROXIMITY.,.8,.6,.6/. &.8/. GPF Certified to comply with ASME A.9. 08 AS America, Inc. MODEL NUMBERS 606B. 606B. 606B.6 606B.7

More information

Installation Instructions

Installation Instructions Installation Instructions MANUAL FLUSH VALVE,. GPF Exposed Flushometer for /" top spud Urinals Certified to comply with: ASSE 07 ANSI/ASME A.9. ADA Compliant 0 AS America, Inc. M9600 Rev.. MODEL NUMBERS

More information

Installation Instructions

Installation Instructions Installation Instructions for -/" Top Spud Fixtures MODEL NUMBERS 607 Series 707 Series OPERATING PRESSURE: Overall Range: 0- psi ** Recommended: psi (flowing) - 80 psi (static) FLOW REQUIREMENT: gpm (9.6

More information

Installation Instructions

Installation Instructions Installation Instructions SELECTRONIC PROXIMITY CONCEALED URINAL FLUSH VALVE.0, 0. & 0. GPF Certified to comply with ASME A.9. 07 AS America, Inc. MODEL NUMBERS 0B.X0 0B.X0 0B.X0 CAUTION: Use only American

More information

Installation Instructions

Installation Instructions Installation Instructions SELECTRONIC CONCEALED TOILET FLUSH VALVE.,.8 &. GPF Certified to comply with ASME A.9. 0 AS America, Inc. MODEL NUMBERS 0B.XX Exposed Back Spud Concealed Back Spud Top Spud CAUTION:

More information

Installation Instructions

Installation Instructions Installation Instructions MANUAL FLUSH VALVE with BEDPAN WASHER For Use with -/" Top Spud Toilets 607.860 (.6gpf) 607.80 (.8gpf) Certified to comply with: ASSE 07 CSA B. ADA Compliant 0 AS America, Inc.

More information

Installation Instructions

Installation Instructions Installation Instructions BEDPAN WASHER For Use with Exposed Flushometer and -/" Top Spud Toilets Certified to comply with: ASSE 07 CSA B. ADA Compliant 0 AS America, Inc. M960 607.800 607.8 MODEL NUMBERS

More information

Installation Instructions

Installation Instructions Installation Instructions SERIN Deck Mount Electronic Proximity Lavatory Faucet Optional 0P00.XXX, " Deck Plate Optional 0P800.XXX, 8" Deck Plate Certified to comply with ASME A.8. 0 AS America, Inc. MODEL

More information

Installation Instructions

Installation Instructions Installation Instructions SERIN Deck Mount Electronic Proximity Lavatory Faucet Certified to comply with ASME A.. 0 American Standard Optional 0P00.XXX, " Deck Plate Optional 0P00.XXX, " Deck Plate 0.

More information

Installation Instructions

Installation Instructions Installation Instructions SERIN Wall Mount Electronic Proximity Lavatory Faucet TE: Please refer to R30 Mounting Kit installation instructions #M4 prior to faucet installation. Certified to comply with

More information

Installation Instructions

Installation Instructions Installation Instructions SELECTRONIC Proximity Integrated Faucet with Optional Above-Deck Mixing Flexible Selectronic Platform with Universal Sensor Easy installation. All electronics in the spout; nothing

More information

Installation Instructions

Installation Instructions Installation Instructions SELECTRONIC Proximity Faucets Cast Spout and Gooseneck Spout Certified to comply with ASME A.8. 0 American Standard 0X.0 0X. MODEL NUMBERS 0X.0 0X. 0X.0 0X. CAUTION: Use only

More information

Installation Instructions

Installation Instructions Installation Instructions SELECTRONIC Moments Proximity Faucets MODEL NUMBERS 0.X 0.X 0B.0X CAUTION: Use only American Standard supplied cable sets. Using non-as supplied cables, or cutting, splicing or

More information

Installation Instructions

Installation Instructions Installation Instructions NextGen Selectronic Integrated Faucet with Optional Above-Deck Mixing & SmarTherm Temperature Limiter CAUTION: Use only American Standard supplied transformers and cable sets.

More information

Installation Instructions

Installation Instructions Installation Instructions SELECTRONIC Integrated Faucet with Above-Deck Mixing CAUTION: Use only American Standard supplied transformers and cable sets. Using non-as supplied cables, or cutting, splicing

More information

Installation Instructions

Installation Instructions Installation Instructions NextGen Selectronic Integrated Faucet with Optional Above-Deck Mixing & SmarTherm Temperature Limiter CAUTION: Use only American Standard supplied transformers and cable sets.

More information

Installation Instructions

Installation Instructions CLEAN FREESTANDING SINGLE CONTROL BATH FILLER Installation Instructions.9 Thank you for selecting American-Standard... the benchmark of fine quality for over 00 years. To ensure that your installation

More information

Installation Instructions

Installation Instructions Installation Instructions COMMERCIAL SYSTEM KITS: 1.5gpm & 2.5gpm 1662.224 1662.214 Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation

More information

Installation Instructions

Installation Instructions Installation Instructions SELECTRONIC Hard-Wired, AC Powered Proximity Integrated Faucet with Above-Deck Mixing Flexible Selectronic Platform with Universal Sensor Easy installation. All electronics in

More information

Installation Instructions 1662SG SG.223

Installation Instructions 1662SG SG.223 COMMERCIAL SHOWER SYSTEM KITS: 1. gpm &. gpm Installation Instructions 1SG.1 1SG. Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation

More information

INSTALLATION INSTRUCTIONS STUDIO S

INSTALLATION INSTRUCTIONS STUDIO S INSTALLATION INSTRUCTIONS STUDIO S 70.0 MONOBLOCK LAVATORY FAUCET WITH SPEED CONNECT Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation

More information

Installation Instructions 1662SG SG.222

Installation Instructions 1662SG SG.222 COMMERCIAL SHOWER SYSTEM KITS: 1. gpm & 2. gpm Installation Instructions 12SG.212 12SG.222 12SG.212 (1.gpm) 12SG.222 (2.gpm) Thank you for selecting American-Standard...the benchmark of fine quality for

More information

Installation Instructions

Installation Instructions Installation Instructions SELECTRONIC Proximity Infection Control Faucet 0 / 0 / 0 Infection Control Faucet shown Installed on American Standard. Infection Control Sink Certified to comply with ASME A..M

More information

Installation Instructions 1662SG SG.224

Installation Instructions 1662SG SG.224 COMMERCIAL SHOWER SYSTEM KITS: 1. gpm &. gpm Installation Instructions 1SG.1 1SG. Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation

More information

Installation Instructions

Installation Instructions ARIANA IN WALL PRESSURE BALANCING BATH AND SHOWER SETS Installation Instructions 0 0 Thank you for selecting American-Standard...the benchmark of fine quality for over 00 years. To ensure that your installation

More information

EDGEMERE DUAL CONTROL WIDESPREAD LAVATORY FAUCET INSTALLATION INSTRUCTIONS

EDGEMERE DUAL CONTROL WIDESPREAD LAVATORY FAUCET INSTALLATION INSTRUCTIONS EDGEMERE DUAL CONTROL WIDESPREAD LAVATORY FAUCET INSTALLATION INSTRUCTIONS 708.80 Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation

More information

INSTALLATION INSTRUCTIONS PATIENCE

INSTALLATION INSTRUCTIONS PATIENCE INSTALLATION INSTRUCTIONS PATIENCE 706.8X DUAL CONTROL WIDESPREAD LAVATORY FAUCET WITH SPEED CONNECT Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure

More information

Installation Instructions Series Series

Installation Instructions Series Series PORTSMOUTH Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found onlyon American Standard faucets. Recommended

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS COMMERCIAL SYSTEM KITS: 1.5 gpm & 2.5 gpm Thank you for selecting American Standard... the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly-please read these

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS COMMERCIAL SYSTEM KITS: 1.5 gpm & 2.5 gpm Thank you for selecting American Standard... the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly-please read these

More information

Installation Instructions

Installation Instructions TIMES SQUARE Spread Lavatory Faucet with Speed Connect Drain Installation Instructions 8.80 8.8 Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS BEALE ELECTRONIC PULL-DOWN KITCHEN FAUCET INSTALLATION INSTRUCTIONS 0 Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation proceeds

More information

Installation Instructions

Installation Instructions COLONY/COLONY SOFT Bidet Faucet and Transfer Valve with Speed Connect Drain Congratulations on purchasing your American Standard faucet with the Speed Connect drain, a feature found only on American Standard

More information

Installation Instructions

Installation Instructions Spread Lavatory Faucet with the Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS AVERY ELECTRONIC PULL-DOWN KITCHEN FAUCET INSTALLATION INSTRUCTIONS 0.0 Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation proceeds

More information

Installation Instructions

Installation Instructions FLUENT Wide Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed

More information

Installation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain

Installation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain Installation Instructions JASMINE 80. Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain Congratulations on purchasing your American Standard faucet with the EverClean finish and Speed

More information

SERIN MONOBLOCK LAVATORY FAUCET with

SERIN MONOBLOCK LAVATORY FAUCET with SERIN MONOBLOCK LAVATORY FAUCET with Speed Connect Drain Installation Instructions 0.0 Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American

More information

Installation Instructions 7024

Installation Instructions 7024 HAMILTON Centerset Lavatory Faucet with EverClean Finish & Speed Connect Drain Installation Instructions 70 Congratulations on purchasing your American Standard faucet with the EverClean finish and Speed

More information

Installation Instructions

Installation Instructions TROPIC Spread Lavatory Faucet with EverClean Finish & SpeedConnect Drain Installation Instructions 708.80 Congratulations on purchasing your American Standard faucet with EverClean finish and Speed Connect

More information

Installation Instructions

Installation Instructions Reliant Single Control Centerset Lavatory Faucet with SpeedConnect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard

More information

NAVAL INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS LIMITED WARRANTY

NAVAL INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS LIMITED WARRANTY NAVAL NAVAL I.I. Code No. 0816176 Rev. 1 INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS Certified Made in the U.S.A Exposed Closet Flushometer 1-1/2" Top

More information

LIMITED WARRANTY. Exposed Urinal Flushometer for 1-1/4" Top Spud MODEL 180 Exposed Urinal Flushometer for 3/4" Top Spud MODEL 186

LIMITED WARRANTY. Exposed Urinal Flushometer for 1-1/4 Top Spud MODEL 180 Exposed Urinal Flushometer for 3/4 Top Spud MODEL 186 ROYAL I.I. Rev. 3 (12/98) Code No. 0816195 Royal Flushometer INSTALLATION INSTRUCTIONS FOR STANDARD EXPOSED WATER CLOSETS AND URINALS NEW! Now featuring Sloan s exclusive Dual Filtered Diaphragm Certified

More information

Installation Instructions

Installation Instructions CADET Centerset Lavatory Faucet with Speed Connect Drain Installation Instructions Congratulations on purchasing your American Standard faucet with the Speed Connect Drain, a feature found only on American

More information

G2 Optima Plus Flushometer

G2 Optima Plus Flushometer 3.2.1 For use with Sloan s introduced May, 2003. For older Optima Plus Flushometers (produced from 1992 2003) and Regal Pro Optima Plus Flushometers see pages 3.2.6 thru 3.2.11. SENSOR MODULE COMPONENT

More information

INSTALLATION INSTRUCTIONS for EXPOSED PULSAR FLUSH VALVES

INSTALLATION INSTRUCTIONS for EXPOSED PULSAR FLUSH VALVES INSTALLATION INSTRUCTIONS for EXPOSED PULSAR FLUSH VALVES Pulsar Water Closet Flush Valve for 1 1/2 Top Spud Pulsar Urinal Flush Valve 3/4 Top Spud Prior to Installation All Plumbing is to be installed

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Flash Shower Valve Rough INSTALLATION INSTRUCTIONS RU0, RU0 RU07, RU08 RU09, RU07E Thank you for selecting American-Standard... the benchmark of fine quality for over 40 years. To ensure that your installation

More information

INSTALLATION INSTRUCTIONS FOR SLIMLINE BEDPAN WASHER WITH EXPOSED ROYAL FLUSHOMETER

INSTALLATION INSTRUCTIONS FOR SLIMLINE BEDPAN WASHER WITH EXPOSED ROYAL FLUSHOMETER BPWL I.I. Code No. 0816191 Rev. 1 INSTALLATION INSTRUCTIONS FOR SLIMLINE BEDPAN WASHER WITH EXPOSED ROYAL FLUSHOMETER Slimline Bedpan Washers BPW-1000 Standard BPW-1005 With Deoseptic Unit BPW-1010 With

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Keefe Single Lever Faucet Monoblock Vessel Model D505C Monoblock Model D500C Thank you for selecting DXV. To ensure that your installation proceeds smoothly, please read these

More information

Installation Instructions Series

Installation Instructions Series PORTSMOUTH MONOBLOCK LAVATORY FAUCET with Speed Connect Drain Installation Instructions 70.0 7.0 Series 7.0 Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature

More information

Installation Instructions

Installation Instructions BERWICK / BOULEVARD MONOBLOCK LAVATORY FAUCET with Speed Connect Drain Installation Instructions 70.0 7.0 Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature

More information

Aquaflush. Z6000 Series Aquaflush Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual Z6000 Z6003

Aquaflush. Z6000 Series Aquaflush Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual Z6000 Z6003 Z6000 Series Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual Patented and Patents Pending Z6000 ADA Z6003 Exposed Closet/Urinal Systems Z6000 Z6001 Z6003 Z6010 Z6014 Z6017 Z6096

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Randall Single Lever Lavatory and Vessel Faucets Lavatory Model D500C Vessel Model D505C Model D506C Thank you for selecting DXV. To ensure that your installation proceeds smoothly,

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS ICS Sink with Selectronic IC Faucet* Models: 98., 98.00 & 98.50 Introduction: Thank you for selecting our products...products which have been the benchmarks of fine quality for

More information

AquaSense AV ZR Series Sensor-Operated, Battery-Powered Flushometer Installation, Operation, Maintenance and Parts Manual

AquaSense AV ZR Series Sensor-Operated, Battery-Powered Flushometer Installation, Operation, Maintenance and Parts Manual AquaSense AV ZR Series Sensor-Operated, Battery-Powered Flushometer Installation, Operation, Maintenance and Parts Manual Patented and Patents Pending ZR6000AV ZR6003AV Sensor-Operated, Battery-Powered

More information

INSTALLATION INSTRUCTIONS for EXPOSED SENSOR-FLUSH FLUSH VALVES

INSTALLATION INSTRUCTIONS for EXPOSED SENSOR-FLUSH FLUSH VALVES INSTALLATION INSTRUCTIONS for EXPOSED SENSOR-FLUSH FLUSH VALVES Sensor-Flush Water Closet Flush Valve for 1 1/2 Top Spud Sensor-Flush Urinal Flush Valve 3/4 Top Spud Prior to Installation All Plumbing

More information

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED FLUSHOMETER WITH WALL BOX CONCEALED CLOSET & URINAL INSTALLATIONS

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED FLUSHOMETER WITH WALL BOX CONCEALED CLOSET & URINAL INSTALLATIONS -l.l. Code No. 0816168 Rev. 1A INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS OPERATED FLUSHOMETER WITH BOX CONCEALED CLOSET & URINAL INSTALLATIONS Concealed Closet Flushometer with Wall Box 1-1/2" Back Spud

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS MODEL: LUGARNO 23580075 (RH-5910) 23580134 (RH-5910L) 1 REV C Restoration Hardware Faucet Product Size Specification Diagram Dimensions are in Inches and Approximation of a Typical

More information

Troubleshooting Guide HYBRIDFLUSH AEF-801 SERIES

Troubleshooting Guide HYBRIDFLUSH AEF-801 SERIES PUSH Troubleshooting Guide HYBRIDFLUSH AEF-80 SERIES AUTOMATIC/MANUAL FLUSH VALVE SYSTEM FOR WATER CLOSETS (TOILETS) AND URINALS Advanced Modern Technologies Corporation 9800 Nordhoff Place, Chatsworth,

More information

INSTALLATION INSTRUCTIONS. Automatic Sensor Retrofit Kit For Urinals and Toilets ZERK-CP Chrome-Plated Cover ZERK-CPM Chrome-Plated Metal Cover

INSTALLATION INSTRUCTIONS. Automatic Sensor Retrofit Kit For Urinals and Toilets ZERK-CP Chrome-Plated Cover ZERK-CPM Chrome-Plated Metal Cover Automatic Sensor Retrofit Kit For Urinals and Toilets ZERK-CP Chrome-Plated Cover ZERK-CPM Chrome-Plated Metal Cover INSTALLATION INSTRUCTIONS FV2001 Page 1 Metroflush Z6200 Series Metroflush Piston-Operated

More information

Installation and Owner s Manual HYBRIDFLUSH AEF-801 SERIES

Installation and Owner s Manual HYBRIDFLUSH AEF-801 SERIES PUSH Installation and Owner s Manual HYBRIDFLUSH AEF-801 SERIES AUTOMATIC/MANUAL FLUSH VALVE SYSTEM FOR WATER CLOSETS (TOILETS) AND URINALS Advanced Modern Technologies Corporation 19800 Nordhoff Place,

More information

AquaSense AV ZER Series

AquaSense AV ZER Series AquaSense AV ZER Series Automatic, Sensor-Operated Battery-ometer Installation, Operation, Maintenance, and Parts Manual Patented and Patents Pending ZER6000AV-CP ZER6000AV-CPM ADA ZER6003AV-CP ZER6003AV-CPM

More information

AquaSense ZTR Series

AquaSense ZTR Series AquaSense ZTR Series Automatic Sensor-Operated Piston Type Flushometer for Water Closets and Urinals Installation, Operation, Maintenance, and Parts Manual Water Closet Models: ZTR6200-ONE 1.1 gpf ZTR6200EV

More information

INSTALLATION INSTRUCTIONS SLOAN SERIES 900 HYDRAULIC FLUSHING SYSTEM FLUSHOMETERS EXPOSED CLOSET, URINAL & SERVICE SINK INSTALLATIONS.

INSTALLATION INSTRUCTIONS SLOAN SERIES 900 HYDRAULIC FLUSHING SYSTEM FLUSHOMETERS EXPOSED CLOSET, URINAL & SERVICE SINK INSTALLATIONS. HY-EXPOSED-l.l. Code No. 0816300 INSTALLATION INSTRUCTIONS SLOAN SERIES 900 HYDRAULIC FLUSHING SYSTEM FLUSHOMETERS EXPOSED CLOSET, URINAL & SERVICE SINK INSTALLATIONS Exposed Closet Flushometer 1-1/2"

More information

AquaSense AV ZER Series

AquaSense AV ZER Series AquaSense AV ZER Series Automatic Sensor-Operated, Battery-Powered Flushometer Installation, Operation, Maintenance, and Parts Manual Patented and Patents Pending ZER6000AV-CP ZER6000AV-CPM Sensor-Operated,

More information

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED URINAL INSTALLATIONS

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED URINAL INSTALLATIONS EL-1500 l.l. Code No. 0816164 Rev. 2 INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED URINAL INSTALLATIONS Exposed Urinal Flushometer 1-1/4" Top Spud 180 ES-S

More information

Aquaflush. Z6100 Series Aquaflush Concealed Flushometer Installation, Operation, Maintenance, and Parts Manual Z6140

Aquaflush. Z6100 Series Aquaflush Concealed Flushometer Installation, Operation, Maintenance, and Parts Manual Z6140 Z6100 Series Concealed Flushometer Installation, Operation, Maintenance, and Parts Manual Patented and Patents Pending Z6140 Concealed Closet/Urinal Systems Z6140 Z6142 Z6143 Z6144 Z6150 Z6152 Z6154 Z6155

More information

AquaSense TM ZTS6200EV Series

AquaSense TM ZTS6200EV Series AquaSense TM EV ZTS6200EV Series Automatic Sensor-Operated, Battery-Powered Flushometer Installation, Operation, Maintenance, and Parts Manual Patented and Patents Pending ZTS6200EV Flushometer for Water

More information

AquaSense ZTR Series

AquaSense ZTR Series AquaSense ZTR Series Automatic Sensor-Operated, Battery-Powered Flushometer Installation, Operation, Maintenance, and Parts Manual Models: ZTR6200-ONE 1.1 gpf ZTR6200EV 1.28 gpf ZTR6200-WS1 1.6 gpf Sensor-Operated,

More information

Royal. Flushometers. Repair Parts and Maintenance Guide PARTS LIST ITEM 10A. SLIP JOINT GASKETS AND RINGS

Royal. Flushometers. Repair Parts and Maintenance Guide PARTS LIST ITEM 10A. SLIP JOINT GASKETS AND RINGS Royal Flushometer Valve Body Body only Body with tail Consuly factory for proper application PARTS LIST 1. 0301172 A-72 CP Cover A-72-HE CP High Efficiency Cover 2. 0301168 A-71 Inside Cover 3. Dual Filtered

More information

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED CLOSET INSTALLATIONS

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED CLOSET INSTALLATIONS EL-1500-L l.l. Code No. 08115 Rev. 2 INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED CLOSET INSTALLATIONS Exposed Closet Flushometer 1-1/2" Top Spud Model

More information

AquaVantage AV Z6100AV Series AquaVantage Concealed Flushometer Installation, Operation, Maintenance and Parts Manual

AquaVantage AV Z6100AV Series AquaVantage Concealed Flushometer Installation, Operation, Maintenance and Parts Manual AquaVantage AV Z6100AV Series AquaVantage Concealed Flushometer Installation, Operation, Maintenance and Parts Manual Patented and Patents Pending Z6140AV AquaVantage Concealed Closet/Urinal Systems Z6140AV

More information

OPERATION & MAINTENANCE MANUAL HB-8000C Series Flush Valve (includes HB8RFKC)

OPERATION & MAINTENANCE MANUAL HB-8000C Series Flush Valve (includes HB8RFKC) ISO 9001 Certified OPERATION & MAINTENANCE MANUAL HB-8000C Series Flush Valve (includes HB8RFKC) www.hydrotekintl.com 5055 Forsyth Commerce Rd, Ste 124, Orlando, FL 32807 Phone (800) 922-9883 Fax (866)

More information

FOR USE WITH SLOAN S ORIGINAL OPTIMA PLUS FLUSHOMETER PRODUCED FROM AND REGAL PRO OPTIMA PLUS PRODUCED AFTER MAY, 2003

FOR USE WITH SLOAN S ORIGINAL OPTIMA PLUS FLUSHOMETER PRODUCED FROM AND REGAL PRO OPTIMA PLUS PRODUCED AFTER MAY, 2003 Maintenance Guide SENSOR OPERATED VALVES FOR USE WITH SLOAN S ORIGINAL OPTIMA PLUS FLUSHOMETER PRODUCED FROM 1992-2003 AND REGAL PRO OPTIMA PLUS PRODUCED AFTER MAY, 2003 The Sloan Valve Company introduced

More information

AquaSense TM ZEG Series

AquaSense TM ZEG Series AquaSense TM EV ZEG Series Automatic Sensor-Operated, Battery-Powered Flushometer Installation, Operation, Maintenance, and Parts Manual Patented and Patents Pending ZEG6003EV Flushometer for Z5798 Low

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS 23530095 23530021 MODEL: Modern 23530021 (RH-6540) 23530095 (RH-6540X) 70010905 (TRRH-3-6540) 1 REV D Restoration Hardware Balance Pressure Shower Set Specification Diagram All

More information

Aquaflush Z6000 Series Aquaflush Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual

Aquaflush Z6000 Series Aquaflush Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual Aquaflush Z6000 Series Aquaflush Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual Patented and Patents Pending Z6000 ADA Aquaflush Exposed Closet/Urinal Systems Z6000 Z6000PL-HET

More information

AquaSense AV ZEMS-IS Series Automatic Sensor-Operated Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual

AquaSense AV ZEMS-IS Series Automatic Sensor-Operated Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual AquaSense AV ZEMS-IS Series Automatic Sensor-Operated Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual Patented and Patents Pending ZEMS6000AV-IS ADA ZEMS6003AV-IS ADA Sensor-Operated

More information

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets Any Application. Any Environment. Code No. 0816407 Rev. 5 (05/16)

More information

Installation Instructions for Pressure Balancing Valve Set with Volume Control. Limited Lifetime Faucet Warranty

Installation Instructions for Pressure Balancing Valve Set with Volume Control. Limited Lifetime Faucet Warranty TM Limited Lifetime Faucet Warranty fluid warrants its faucets to be free from defects in material and workmanship for as long as the original consumer purchaser owns his or her home.* This warranty applies

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS SHOWN WITH TUB-FILLER SET (NOT INCLUDED) MODEL: VINTAGE 690090 (RH-576L) 690040 (RH-576) REV C Restoration Hardware Diverter Trim Kit Product Size Specification Diagram Dimensions

More information

Installation Instructions

Installation Instructions REPRISE TRIM KIT Installation Instructions 555.0 555.0 T55.0 Thank you for selecting Porcher Products. To ensure that your installation proceeds smoothly--please read these instructions carefully before

More information

Installation Instructions

Installation Instructions Instructions Aerada 900 Series Futura Faucet With Battery (BIR) Infrared Control S53-284 4" Centerset/Centershank S53-289 Centerset/Centershank w/plate Table of Contents Pre- Information............2 900

More information

Maintenance Guide. OPTIMA Components:

Maintenance Guide. OPTIMA Components: Maintenance Guide OPTIMA Sensor Activated Flushometers The Sloan OPTIMA automatic electronic Flushometer relies on an infrared sensor to detect a user and activate a flushing cycle. No physical contact

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS SHOWN WITH TUB-FILLER SET (NOT INCLUDED) MODEL: MODERN 50040 (RH-656) 5007 (RH-656X) REV C Restoration Hardware Diverter Trim Kit Product Size Specification Diagram Dimensions

More information

OPERATION & MAINTENANCE MANUAL HB-8000C Series Flush Valve (includes HB8RFKC)

OPERATION & MAINTENANCE MANUAL HB-8000C Series Flush Valve (includes HB8RFKC) ISO 9001 Certified OPERATION & MAINTENANCE MANUAL HB-8000C Series Flush Valve (includes HB8RFKC) www.hydrotekintl.com 5055 Forsyth Commerce Rd, Ste 124, Orlando, FL 32807 Phone (800) 922-9883 Fax (866)

More information

Royal Flushometer PARTS LIST

Royal Flushometer PARTS LIST Royal Flushometer Tailpiece Control Stop and Caps Valve Body Body only Body with tail Consuly factory for proper application ITEM 0A. SLIP JOINT GASKETS AND RINGS TAILPIECES, CONTROL STOPS AND FLUSH CONNECTIONS

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS MODEL: LUGARNO RH-5960 Restoration Hardware RomanTub Product Size Specification Diagram Recommended Deck Hole Size /4 Diameter Dimensions are in Inches and Approximation of a

More information

Royal Flushometer. Manual Flushometers. Repair Parts and Maintenance Guide PARTS LIST

Royal Flushometer. Manual Flushometers. Repair Parts and Maintenance Guide PARTS LIST Royal Flushometer Tailpiece Control Stop and Caps Valve Body Body only Body with tail Consuly factory for proper application TAILPIECES, CONTROL STOPS AND FLUSH CONNECTIONS For additional information on

More information

AquaSense AV ZEMS-IS Series w/ HW6 Power Converter Automatic Sensor-Operated Exposed Flushometer Installation, Operation, Maintenance and Parts Manual

AquaSense AV ZEMS-IS Series w/ HW6 Power Converter Automatic Sensor-Operated Exposed Flushometer Installation, Operation, Maintenance and Parts Manual AquaSense AV ZEMS-IS Series w/ HW6 Power Converter Automatic Sensor-Operated Exposed Flushometer Installation, Operation, Maintenance and Parts Manual Patented and Patents Pending ZEMS6000AV-IS ZEMS6003AV-IS

More information

Installation Instructions

Installation Instructions Installation Instructions Thermostatic Valve and Trim Model No. RH-5944 1 REV.A Restoration Hardware Product Size Specification Diagram General Characteristics In case of instantaneous heaters, hot water

More information

AquaSense ZTR Series

AquaSense ZTR Series AquaSense ZTR Series Automatic Sensor-Operated Piston Type Flushometer for Water Closets and Urinals Installation, Operation, Maintenance, and Parts Manual Water Closet Models: ZTR6200-ONE 1.1 gpf ZTR6200EV

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS MODEL: GRAFTON RH-510 1 REV.A Restoration Hardware Balance Pressure Tub /Shower Set Specification Diagram Ensure that the stop ring () is correctly installed, prior to finished

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS 000 7800 00 MODEL: Modern 000 (RH-600) 00 (RH-600X) 7800 (TRRH-600) REV E Restoration Hardware Faucet Product Size Specification Diagram Recommended Deck Hole Size -/8 Diameter

More information

Instructions. Certifications Chrome less spray Chrome with spray 10-K82-WNCH-AD-Z Chrome less spray 10-K82-WYCH-AD-Z Chrome with spray

Instructions. Certifications Chrome less spray Chrome with spray 10-K82-WNCH-AD-Z Chrome less spray 10-K82-WYCH-AD-Z Chrome with spray Instructions *Image may vary slightly from actual product Tools Required Adjustable Wrench Groove Joint Pliers Pipe Wrench Phillips Screwdriver Pipe Tape or pipe thread compound Safety Tips If you solder

More information

Battery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST

Battery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST 1A 1B 8 EAF-100/150 I.I. Rev. 0a (11/02) Code No. 0816542 INSTALLATION INSTRUCTIONS ELECTRONIC, SENSOR OPERATED LAVATORY FAUCETS EAF-150 Series Battery Powered Sensor Operated Lavatory Faucets 2 3 7 10

More information