RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

Size: px
Start display at page:

Download "RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide"

Transcription

1 RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide UNLESS SPECIFICALLY AGREED TO IN WRITING, SELLER (A) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION; (B) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES, DAMAGES, COSTS OR EXPENSES, WHETHER SPECIAL, DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER S RISK; AND (C) REMINDS YOU THAT IF THIS MANUAL IS IN ANY LANGUAGE OTHER THAN ENGLISH, ALTHOUGH STEPS HAVE BEEN TAKEN TO MAINTAIN THE ACCURACY OF THE TRANSLATION, THE ACCURACY CANNOT BE GUARANTEED. APPROVED CONTENT IS CONTAINED WITH THE ENGLISH LANGUAGE. (D) INFORMS YOU THE INFORMATION IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. (E) RESERVES ALL RIGHTS

2 Contents 1 Safety Warnings Transformer Module Overview Installation Inspecting the Transformer Unpacking the Transformer Cabinet Installation Notes Rackmount Installation Tower Installation Connecting The Step Down Transformer To The Ups Input / Output Cable Selection Input / Output Cable Connections RT 06XFR-EA Input / Output Cable Connections RT 10XFR-EA Operation Start-Up In Normal AC Mode Start-Up In Battery Mode Turning Off The Step Down Transformer In Normal AC Mode Turning Off The Step Down Transformer In Battery Mode Specifications

3 1 Safety Warnings IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions that you should follow during installation and maintenance of the UPS and batteries. Please read all instructions before operating the equipment and save this manual for future reference. DANGER THE TRANSFORMER CONTAINS LETHAL VOLTAGES. ONLY AUTHORIZED SERVICE PERSONNEL SHOULD PERFORM ALL REPAIRS AND SERVICE. THERE ARE NO USER SERVICEABLE PARTS INSIDE THE TRANSFORMER. WARNING The transformer output may carry live voltage even when the transformer is not connected to an AC supply. To reduce the risk of fire or electric shock, install the transformer a temperature and humidity controlled, indoor environment, free of conductive contaminants. Ambient temperature must not exceed 40 C (104 F). Do not operate near water or excessive humidity (95% maximum). To reduce the risk of fire, connect only to a circuit provided with branch circuit overcurrent protection in accordance with the National Electrical Code (NEC), ANSI/NFPA 70. Output overcurrent protection and disconnect switch must be provided by others. If the transformer requires any type of transportation, verify that the transformer is disconnect the UPS. WARNING Batteries can present a risk of electrical shock or burn from high short-circuit current. Observe proper precautions. Only qualified service personnel with knowledge of batteries and the required precautions should perform servicing. Keep unauthorized personnel away from batteries. Proper disposal of batteries is required. Refer to your local codes for disposal requirements. Never dispose of batteries in a fire. Batteries may explode when exposed to flame. WARNING To reduce the risk of electrical shock and possible damage to the connected equipment due to the risk of AC current leakage, ensure that the transformer is properly grounded

4 CAUTION To reduce the risk of damage to the connected equipment the AC input of the Step Down Transformers must be the same as the UPS's output voltage setting. Transformers must only be connected and operated with their respective UPS models and the load capacity derated as listed in the table below. Transformer RT 06XFR-EA RT 10XFR-EA UPS RT 1106E-UL RT 1110E-UL Derated Load Capacity 5,556 VA 5,000 Watts 8,889 VA 8,000 Watts - 3 -

5 2 Transformer Module Overview RT 06XFR-EA 1. The Load 4 circuit breaker will trip in the event the load exceeds the power rating. 2. Load 4: 120V output receptacles (3-5-15/20R). 3. The Load 3 circuit breaker will trip in the event the load exceeds the power rating. 4. Load 3: 120V output receptacles (3-5-15/20R) 5. The Load 2 circuit breaker will trip in the event the load exceeds the power rating. 6. Load 2: 208V output receptacle (1 - L6-20R). NOTE: The default output voltage is 208V. (Optional 240V is available, but must be configured at the factory.) 7. The Load 1 circuit breaker will trip in the event the load exceeds the power rating. 8. Load 1: 208V output receptacle (1 - L6-30R). 9. The input circuit breaker will trip in the event the load exceeds the RT-XFR's power rating. 10. The input power cord is for connecting to the output terminal block on the UPS. 11. RT-XFR's circuit breaker will trip in the event that the RT-XFR becomes overheated. 12. Input voltage selection switch (208 / 240V). The default setting is 208V

6 RT 06XFR-EA 1. The Load 4 circuit breaker will trip in the event the load exceeds the power rating. 2. Load 4: 120V output receptacles (4-5-15/20R). 3. The Load 2 circuit breaker will trip in the event the load exceeds the power rating. 4. Load 2: 120V output receptacles (4-5-15/20R). 5. The Load 2 circuit breaker will trip in the event the load exceeds the power rating. 6. Load 3: 208V output receptacle (1 - L6-20R). 7. The Load 1 circuit breaker will trip in the event the load exceeds the power rating. 8. Load 1: 208V output receptacle (1 - L6-30R). 9. The input circuit breaker will trip in the event the load exceeds the RT-XFR's power rating. 10. RT-XFR's circuit breaker will trip in the event that the RT-XFR becomes overheated. 11. Input terminal block (208V / 240V) is for connecting the input power cable that comes from the output terminal block of the UPS. 12. Output terminal block for optional hardwiring the load. The available output voltages are 120V / 208V / 240V. NOTE: The two 120V outputs are individual 5KVA outputs and they CANNOT be paralleled

7 3 Installation Be sure to read the installation placement and all the cautions before installing the RT-XFR. Place the unit in the final desired location and complete the rest of the installation procedure. 3.1 Inspecting the Transformer If any of the equipment received has been damaged during shipment, keep the shipping cartons and packing materials in case a return is required and file a claim for shipping damage. If you discover damage after acceptance, file a claim for concealed damage. To file a claim for shipping damage or concealed damage: 1) File with the carrier within 15 days of receipt of the equipment; 2) Send a copy of the damage claim within 15 days to your service representative. 3.2 Unpacking the Transformer Cabinet CAUTION Unpacking the Transformer cabinet in a low-temperature environment may cause condensation to occur in and on the cabinet. Do not install the cabinet until the inside and outside of the cabinet are absolutely dry (hazard of electric shock). The cabinet is heavy. Be careful unpacking and moving the cabinet. To unpack the cabinet and accessories: 1. Open the outer carton and remove the accessories packaged with the cabinet. 2. Carefully lift the cabinet out of the outer carton. 3. Discard or recycle the packaging in a responsible manner. Place the cabinet in a protected area that has adequate airflow and is free of humidity, flammable gas, and corrosion. 3.3 Installation Notes Place the Transformer with the UPS in an indoor, clean and stable environment, avoiding vibration, dust, humidity, flammable gas and liquid, corrosive objects. Avoid direct sunlight. To avoid high room temperature, an extraction fan is recommended to be installed. Optional air filters are available if the UPS operates in a dusty environment. The environment temperature around the Transformer and UPS should be keptin a range of 0 ~40. If the environment temperature exceeds 40, the rated load capacity should be reduced by 12% per 5. The max temperature must not be higher than 50. If the Transformer is dismantled under low temperature, it might be in a condensing condition. The Transformer and UPS can't be installed unless the internal and external of the equipment is fully dry. Otherwise, there will be in danger of electric shock

8 Route power cords so they cannot be walked on or damaged. The AC inputs of the Step Down Transformers must ONLY be connected to the output of their respective UPS models. The RT Series Transformer is not intended for use in a computer room as defined in the Standard for the Protection of Electronic Computer/Data Processing Equipment ANSI/NFPA 75. Batteries should be mounted in an environment where the temperature is within the required specs. Temperature is a major factor in determining battery life and capacity. In a normal installation, the battery temperature is maintained between 15 C and 25 C. Keep batteries away from heat sources or main air ventilation area, etc. Should the equipment not be installed immediately it must be stored so as to protect it against excessive humidity and or heat sources. CAUTION The external vents and openings on the unit are provided for ventilation to ensure reliable operation of the unit and to protect the unit from over-heating, Vents and openings must not be blocked or covered. Do not insert any objects into the vents or openings that may hinder the ventilation. Install the unit in a well ventilated area, away from excess moisture, heat, dust, flammable gas or explosives. Leave adequate space (at least 15cm) around all sides of the unit for proper ventilation. Do not mount the unit with its front or rear panel facing down at any angle. Before usage, allow the unit to adjust to room temperature (20 C~25 C or 68 F~77 F) for at least one hour to avoid moisture condensing inside the unit. 3.4 Rackmount Installation Use the following placement when rack mounting: The RT-XFR should be installed close to the bottom of the rack. Then install the Battery Pack right above the RT-XFR. Then install the UPS right above the Battery Pack. CAUTION The RT-XFR, UPS and Battery Pack are extremely heavy. Do not use the mounting brackets to lift the step down transformer. The mounting brackets are for securing the unit to the rack

9 Use the included rackmount brackets and screws to mount the RT-XFR in a rack by following the steps below. 1. Attach the rackmount brackets to the mounting holes on the side panel of the RT-XFR as shown below. 2. Install the RT-XFR into the Rail kit. See the figure below. 3.5 Tower Installation The tower configuration allows the user to install the RT-XFR in the up-right position. Tower stands are provided with the UPS. The tower stand extenders are provided with the RT-XFR

10 3.6 Connecting The Step Down Transformer To The Ups 3. Before connecting to the input / output transformer terminals read all of the Cautions and Warnings and observe the following: a) Ensure that the UPS is turned off and not connected to the AC source or the battery source before any connections are made. b) Calculate the power consumption of the load to ensure that an overload condition does not occur. c) Ensure that the terminal block screws are secured after connecting the input / output wires. The terminal block screws should be torque to 18±2Kgf.cm (requires a 3/16" flat-head screwdriver). d) Ensure that the RT-XFR and the UPS are properly grounded. 2. The input power for the RT-XFR must be single-phase in accordance with its rating label and the specifications in this manual. The RT-XFR's input voltage setting must be the same as the UPS's output voltage setting. RT 06XFR-EA - 9 -

11 RT 10XFR-EA Input / Output Cable Selection Input / Output cable selection Temperature Rating 6KVA 10KVA 60 C / 75 C #10 AWG (Cu) #8 AWG (Cu) NOTE: Use copper wire only. (In accordance with National Electrical Code (NEC), install suitable conduit and bushing.) NOTE: The AC inputs of these Step Down Transformers are ONLY intended to be connected to the output of their respective UPS models. NOTE: The RT-XFR's input voltage setting must be the same as the UPS's output voltage setting Input / Output Cable Connections RT 06XFR-EA See the UPS users manual for UPS input and output connections. 1. Remove the terminal block cover plate from the rear panel of the RT-XFR 2. Connect the attached #10 AWG input power cord on the RT-XFR to the output terminal block on the UPS. 3. Set the input voltage select switch on the rear panel of the RT-XFR to the appropriate voltage (208V / 240V). 4. Plug the equipment into the output receptacles on the rear panel of the RT-XFR. NOTE: The default setting is 208V. The RT-XFR's input voltage setting must be the same as the UPS's output voltage setting

12 3.6.3 Input / Output Cable Connections RT 10XFR-EA See the UPS users manual for UPS input and output connections. 1. Connect the end of the #8 AWG input power cable labeled "TO XFR" to the appropriate terminals on the AC input terminal block on the RT-XFR and secure. The pins for the input cable are included. a) Connect the black wire labeled L1 / L2 on the input power cable to the RT-XFR AC input terminal block labeled L1 for 240V or L2 for 208V and secure. b) Connect the white wire labeled L3 on the input power cable to the RT-XFR AC input terminal block labeled L3 and secure. c) Connect the green wire labeled G on the input power cable to the RT-XFR AC input terminal block ground terminal and secure. NOTE: The RT-XFR's input voltage setting must be the same as the UPS's output voltage setting. 2. Connect the other end of the #8 AWG input power cable labeled "TO UPS" to the output terminal block on the UPS and secure. a) Connect the black wire labeled L on the input power cable to the UPS out- put terminal block labeled L and secure. b) Connect the white wire labeled N on the input power cable to the UPS out- put terminal block labeled N and secure. c) Connect the green wire labeled G on the input power cable to the UPS out- put terminal block ground terminal and secure. 3. Re-install the terminal block cover plate on the RT-XFR. 3. Before re-installing the terminal block cover box on the UPS, see the UPS users manual for the UPS input and output connections. 5. Plug the equipment into the output receptacles on the rear panel of the RT-XFR. The RT 10XFR- EAh as a terminal block for hardwiring the output. Refer to the figure below for the input / output connections. The pins for the output cable are included. NOTE: The two 120V outputs are individual 5KVA outputs and CANNOT be paralleled. Input / Output terminal block for the RT 10XFR-EA 120V outputs: La - N: 50A max, Lb - N: 50A max, the combined total for both: 83.4A max 208V output: Lc - Ld: 48.1A max 240V output: La - Lb: 41.7A max NOTE: Default voltages for the output receptacles are 120V and 208V. 240V is available, but only as a hardwire option at the output terminal block

13 4 Operation 4.1 Start-Up In Normal AC Mode The UPS must be connected to utility power and there must be an acceptable AC voltage present. The Battery Pack(s) must be connected to the UPS and the DC breaker(s) on the rear panel of the Battery Pack(s) must be in the on position. The input of the RT-XFR must be connected to the output of the UPS. The equipment is plugged into the output receptacles on the RT-XFR. 1. Turn on the input breaker on the rear panel of the UPS. The fans will turn on, the bps LED will turn on. The UPS is now in the Bypass mode. NOTE: If there is a power interruption while UPS is in Bypass mode the load will not be backed up. 2. Turn on all of the Load breakers on the rear panel of the RT-XFR. 3. Turn on the connected equipment one at a time. 4. Press and release the On Button after the first beep to turn the UPS on. 5. The UPS will start-up and perform a self-diagnosis for approximately 3- seconds. The UPS system is ready for normal opeartion. See the UPS user's manual for more information. 4.2 Start-Up In Battery Mode The Battery Pack(s) must be connected to the UPS and the DC breaker(s) on the rear panel of the Battery Pack(s) must be in the on position. The input of the RT-XFR must be connected to the output of the UPS. The equipment must be plugged into the output receptacles on the RT-XFR. 1. Turn on the input breaker on the rear panel of the UPS. 2. Press and release the On/ Button after the first beep to turn the UPS on. 3. The fans will turn on, then the UPS will start-up and perform a self-diagnosis for approximately 3- seconds. 4. Turn on all of the Load breakers on the rear panel of the RT-XFR. 5. Turn on the connected equipment one at a time. See the UPS user's manual for more information. 4.3 Turning Off The Step Down Transformer In Normal AC Mode 1. Press and release the Off Button on the front panel of the UPS after the first beep to transfer the UPS to the Bypass mode. 2. Turn off all of the connected equipment. 3. Turn off all of the Load breakers on the rear panel of the RT-XFR. 4. Turn off the input breaker on the rear panel of the UPS. 5. Turn off the DC breaker(s) on the rear panel of the Battery Pack(s). 4.4 Turning Off The Step Down Transformer In Battery Mode 1. Turn off all of the connected equipment. 2. Turn off all of the Load breakers on the rear panel of the RT-XFR. 3. Press and release the Off Button after the first beep to turn the UPS off. 4. Turn off the input breaker on the rear panel of the UPS. 5. Turn off the DC breaker(s) on the rear panel of the Battery Pack(s)

14 5 Specifications SYSTEM SPECIFICATIONS Model Number RT 06XFR-EA RT 10XFR-EA Topology INPUT Number of Phase Voltage (Selectable) Frequency Current (Max) Protection Connection OUTPUT Voltage (Selectable) Isolation, Step Down Tansformer, Sine Wave Single (1 2W +G) 208 (default) / 240VAC 50 / 60Hz 208VAC - 24Amps 240VAC - 21Amps Resettable Circuit Breaker Voltage Regulation Nominal +/-3% Frequency 208VAC - 49Amps 240VAC Amps Attached 2' open-end Terminal Block #10 AWG power cord Hardwire only 208 & 120VAC (Default) / 240VAC (Optional) 50 / 60Hz Power (Max) 6KVA / 6K Watts 10KVA / 10K Watts Harmonic Distortion Efficiency Waveform Type Protection ENVIRONMENTAL Operating Temperature (max) 3% (Full Linear Load) 95% (Full Load) True Sine Wave Resettable Circuit Breaker 0 to 40 C (+32 to +104 F) Storage Temperature -15 to +50 C (+5 to +122 F) Operating/Storage Humidity Operating Elevation Storage Elevation 0 ~ 95% Non-Condensing 0 to 2,000m (0 to +6,562 ft) 0 to 15,000m (0 to +49,213 ft) Audible Noise at 1 m (3 ft.) 50 dba 60 dba PHYSICAL L X W X H 685 x 440 x 86.5 mm 677 x 443 x 131 mm Weight - Net 46.5 Kg 74.0 Kg L X W X H 850 x 580 x 230 mm 800 x 570 x 265 mm REGULATORY COMPLIANCE ctuvus Safety and Approvals (Conforms to UL :2007 R12.11, CSA-C22.2 No A1:2011) EMC IEC

M Series External Battery Frame. User Guide

M Series External Battery Frame. User Guide M Series External Battery Frame User Guide M 24-065-144 BF-NB M 24-100-144 BF-NB M 24-120-144 BF-NB UNLESS SPECIFICALLY AGREED TO IN WRITING, SELLER (A) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY

More information

RT Series Battery Pack UL for RT 6 and 10 kva UPS UL. Extended Battery Pack. User Guide

RT Series Battery Pack UL for RT 6 and 10 kva UPS UL. Extended Battery Pack. User Guide RT Series Battery Pack UL for RT 6 and 10 kva UPS UL RT 06E 20-007-120 BPX-B-UL RT 10E 20-009-120 BPX-B-UL Extended Battery Pack User Guide UNLESS SPECIFICALLY AGREED TO IN WRITING, SELLER (A) MAKES NO

More information

Electrical Installation

Electrical Installation Electrical Installation Symmetra LX Tower UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva 200 V, 4-16 kva 208/240 V, 4-16 kva 220/230/240 V, 4-16 kva Important Safety Messages SAVE

More information

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software User Manual Thank you for purchasing the Defender 650/1200/1600. It is designed to provide safe and reliable power protection to your precious electronics equipment. Before you start using the product,

More information

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090529 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW Line/Load Reactors are components designed to improve the

More information

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation M T E C o r p o r a t i o n MATRIX FILTER SERIES B 380-415 Volts, 50HZ USER MANUAL PART NO. INSTR - 015 REL. 040709 2003 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter

More information

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation M T E C o r p o r a t i o n MATRIX FILTER SERIES B 380-415 Volts, 50HZ USER MANUAL PART NO. INSTR - 015 REL. 060628 2006 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter

More information

General Precautions. Personnel Precautions

General Precautions. Personnel Precautions USER MANUAL General Precautions 1. Before using Inverex, read all instructions and cautionary markings on : (1) Inverex (2) the batteries (3) this manual 2. CAUTION --To reduce risk of injury, charge only

More information

P90L-ISO6MB & ISO10MB

P90L-ISO6MB & ISO10MB P90L-ISO6MB & ISO10MB for 6kVA, 10kVA Models User & Installation Manual www.xpcc.com 2014. All rights reserved. (Rev 9/23/14) Table of Contents Important Safety Instructions...3 An Important Notice...3

More information

Delta UPS - Ultron Family. HPH Series, Three Phase 20/30/40/60 kva 208V. User Manual. The power behind competitiveness

Delta UPS - Ultron Family. HPH Series, Three Phase 20/30/40/60 kva 208V. User Manual.   The power behind competitiveness EPO NORMAL BATTERY BYPASS FAULT ESC ON OFF EPO NORMAL BATTERY BYPASS FAULT ESC ON OFF The power behind competitiveness Delta UPS - Ultron Family HPH Series, Three Phase 20/30/40/60 kva 208V User Manual

More information

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3 Atlantic Battery Systems 1065 Market Street Paterson, NJ 07513 Phone: (800) 875-0073 Fax: (973) 523-2344 sales@atbatsys.com www.atbatsys.com SOS1 SOS2 SOS SERIES Spares On Site Battery Cabinet Installation

More information

Powerware Vdc Extended Battery Cabinet User s Guide.

Powerware Vdc Extended Battery Cabinet User s Guide. Powerware 9125 48 Vdc Extended Battery Cabinet User s Guide www.powerware.com FCC Part 15 Class A EMC Statements NOTE This equipment has been tested and found to comply with the limits for a Class A digital

More information

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System USER MANUAL Blazer Vista 1000/1400/2000 Uninterruptible Power System IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for model Blazer Vista 1000/1400/2000

More information

BULL POWER Line Conditioner Regulating Power Bar

BULL POWER Line Conditioner Regulating Power Bar BULL POWER Line Conditioner Regulating Power Bar Auto Voltage Regulation User s Manual TABLE OF CONTENTS INTRODUCTION 1 1. IMPORTANT SAFETY INSTRUCTIONS 2 2. PRESENTATION 2 3. INSTALLATION 3 4. OPERATION

More information

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION... CONTENTS 1. INTRODUCTION...... 1 2. SAFTY INSTRUCTION.......... 2 3. CABLE CONNECTION.......... 4 4. SYSTEM DESCRIPTION............ 5 5. INVERTER OPERATION... 11 6. TROUBLE SHOOTING GUIDE....... 16 7.

More information

USER MANUAL English / Español

USER MANUAL English / Español UPStation GXT LRT TM Battery Cabinet for use with the 1800-3000 VA UPS Units USER MANUAL English / Español IMPORTANT SAFETY INSTRUCTIONS WARNING: Do not attempt to service this product yourself. Opening

More information

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL FORM: MX-TRM-E REL. September 2014 REV. 002 2014 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation

More information

USER MANUAL. Uninterruptible power supply MODEL: 53965,

USER MANUAL. Uninterruptible power supply MODEL: 53965, USER MANUAL Uninterruptible power supply MODEL: 53965, 53966 www.qoltec.com Please check if the package contains: - UPS unit - Power cable (1 x SCHUKO) 1.2 m - User manual This UPS provides comprehensive

More information

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company Manufacturer of Dimensions Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com OWNERS MANUAL April

More information

3 Uninterruptible Power Systems

3 Uninterruptible Power Systems 3 Uninterruptible Power Systems S4K2U and S4K2U-5 Industrial On-Line UPS The true on-line (double conversion) protection offered by the S4K2U Industrial UPS series eliminates a wider range of potential

More information

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. Quick Reference ❶ Performance Data Pages

More information

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8 Contents : 1. INTRODUCTION...1 2. IMPORTANT SAFETY INSTRUCTIONS...2 3. SYSTEM DESCRIPTION...4 3.1 Front Panel...4 4. CONNECTION AND OPERATION...6 5. TROUBLESHOOTING...8 6. MAINTENANCE...9 6.1 Operation...9

More information

MIL-24/2600Q MIL-24/3200DQ

MIL-24/2600Q MIL-24/3200DQ Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121473B OWNER'S

More information

Uninterruptible Power Systems

Uninterruptible Power Systems Sola 4K Industrial On-Line Uninterruptible Power Systems (UPS) The true on-line (double conversion) protection offered by the S4K Industrial UPS series eliminates a wider range of potential power problems

More information

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual DC AC POWER INVERTER LIV 10 / LIV 20 / LIV 30 User Manual Save This Manual Please read this manual carefully prior to storage, installation, wiring, operation and maintenance of the Power Inverter. This

More information

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING dv Sentry TM 208V 600V INSTALLATION GUIDE FORM: DVS-IG-E REL. January 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.

More information

Safety and General Information

Safety and General Information Safety and General Information Symmetra LX Tower Rack-Mount UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva 200 V, 4-16 kva 208/240 V, 4-16 kva 220/230/240 V, 4-16 kva Important Safety

More information

Uninterruptible Power Systems

Uninterruptible Power Systems S4K4U 6 kva and S4K6U 10 kva Industrial On-Line UPS The S4K4U6000 and the S4K6U10000 Industrial UPS Series are the first true On-Line industrial UPS that provide flexible output voltage, an integrated

More information

Genie Smart Cabinet - UPS Powered Distribution Unit User Manual

Genie Smart Cabinet - UPS Powered Distribution Unit User Manual Genie Smart Cabinet - UPS Powered Distribution Unit User Manual M2102_Genie_Breaker_Cabinet_Manual V1.0 2012-06-12 M2102_Genie_Breaker_Cabinet_Manual V1.0 2012-06-12 Table of Contents 1. CAUTION 1 2. IMPORTANT

More information

High Frequency SineWave Guardian TM

High Frequency SineWave Guardian TM High Frequency SineWave Guardian TM 380V 480V INSTALLATION GUIDE FORM: SHF-IG-E REL. January 2018 REV. 002 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation

More information

Galaxy Receiving and Unpacking 09/

Galaxy Receiving and Unpacking 09/ Galaxy 5500 20 120 kva 400 V Receiving and Unpacking 09/2015 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS

More information

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B Users Manual Cobra Plus Stand-By Lighting Inverter Technical Manual #018-0110-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail: techsupport@dspmanufacturing.com

More information

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation M T E C o r p o r a t i o n MTE Series RL Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL. 050516 2002 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RL Line/Load Reactors are components

More information

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING SineWave Guardian TM 380V 600V INSTALLATION GUIDE FORM: SWG-IG-E REL. October 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of

More information

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount Important Safety Messages Read the instructions carefully to become familiar with the equipment before

More information

Switching DC Power Supply

Switching DC Power Supply 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Model 1693, 1694 Switching DC Power Supply INSTRUCTION MANUAL 1 Safety Summary

More information

Galaxy VM. Battery Breaker Box Installation 09/

Galaxy VM. Battery Breaker Box Installation 09/ Galaxy VM Battery Breaker Box Installation 09/2016 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS referred

More information

POWERWARE User s Guide VA.

POWERWARE User s Guide VA. POWERWARE 3110 300 700 VA User s Guide www.powerware.com FCC Part 15 Class B EMC Statements NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant

More information

BRAVER UPS. (Uninterruptible Power System) User s Manual

BRAVER UPS. (Uninterruptible Power System) User s Manual BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.

More information

ADI-125/750 ADI-125/1500 ADI-125/2500

ADI-125/750 ADI-125/1500 ADI-125/2500 Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121094B OWNERS

More information

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount Important Safety Messages Read the instructions carefully to become familiar with the equipment before attempting to install, operate,

More information

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SUT30K Highlights On-line double-conversion topology, VFI operation

More information

Installation and Operation Manual Back-UPS BX1100CI-CN

Installation and Operation Manual Back-UPS BX1100CI-CN Installation and Operation Manual Back-UPS BX1100CI-CN Safety and General Information This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with fluids, or

More information

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA USER MANUAL Uninterruptible Power Supply Line-interactive VCL Series UPS 800 1100 2000 3000 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 /

More information

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation M T E C o r p o r a t i o n dv/dt Filter Series A 440-600 VAC USER MANUAL PART NO. INSTR - 019 REL. 041119 2004 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation dv/dt Filter is designed

More information

1000 Watt Pure Sine Wave Power Inverter, Users Manual

1000 Watt Pure Sine Wave Power Inverter, Users Manual WF-5100 Series 1000 Watt Pure Sine Wave Power Inverter, Users Manual Distributed in the USA and Canada by Arterra Distribution 2021 Aeroplex Drive North. Elkhart, IN. 46514 Phone: 877-294-8997, Fax: 547-294-8698

More information

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System USER MANUAL PowerMust 1400/2000 LCD Uninterruptible Power System IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for model Power Must 1400/2000 LCD that

More information

Uninterruptible Power Supplies

Uninterruptible Power Supplies S4K5U-5C 6 kva International On-Line UPS The new SolaHD S4K5U6K5C Industrial On-Line UPS Series is designed for international usage and provides flexible output voltage, an integrated maintenance bypass

More information

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B Users Manual Defender 1 8.0KW to 14.0KW Online Lighting Inverter Technical Manual #018-0102-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail:

More information

RT Series UPS 6-10kVA UL Vac (0.9 PF) User Guide

RT Series UPS 6-10kVA UL Vac (0.9 PF) User Guide RT Series UPS 6-10kVA UL 208-220-230-240Vac (0.9 PF) User Guide UNLESS SPECIFICALLY AGREED TO IN WRITING, SELLER (A) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR

More information

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

User Manual Back-UPS BX650CI-MS 230 Vac with AVR User Manual Back-UPS BX650CI-MS 230 Vac with AVR Overview Safety and General Information Inspect the package contents upon receipt. Notify the carrier and dealer if there is any damage. Read the Safety

More information

3 Uninterruptible Power Systems

3 Uninterruptible Power Systems Sola 4K Industrial On-Line Uninterruptible Power Systems (UPS) The true on-line (double conversion) protection offered by the S4K Industrial UPS series eliminates a wider range of potential power problems

More information

Security Plus Online Uninterruptible Power Supply

Security Plus Online Uninterruptible Power Supply Security Plus Online Uninterruptible Power Supply 1 2 GENERAL SAFETY INSTRUCTIONS Warnings in this manual appear in any of four ways: DANGER Danger- The danger symbol is a lightning bolt mark enclosed

More information

3 Uninterruptible Power Systems

3 Uninterruptible Power Systems S4K2U and S4K2U-5 Industrial On-Line UPS The true on-line (double conversion) protection offered by the S4K2U Industrial UPS series eliminates a wider range of potential power problems (spikes, surges

More information

Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva

Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva Start UP Guide Symmetra LX Tower Rack-Mount UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva 200 V, 4-16 kva 208/240 V, 4-16 kva 220/230/240 V, 4-16 kva Important Safety Messages SAVE

More information

Owner's/Installation Manual

Owner's/Installation Manual Owner's/Installation Manual Power Management Module (PMM) and Starter Kit NOTE: The starter kit must be purchased and installed prior to individual PMM usage. Model Numbers: 00686-0 PMM 00699-0 PMM WITH

More information

SEAUPS-III Uninterruptible Power Conditioning System. System Manual

SEAUPS-III Uninterruptible Power Conditioning System. System Manual SEAUPS-III Uninterruptible Power Conditioning System System Manual N9246 Hwy 80 South, Suite 7, Necedah, WI 54646 Tel: 608-565-5877 Fax: 608-565-5879 Email: sales@lpc-ups.com Website: www.lpc-ups.com BILS-10012

More information

Maintenance Bypass Switch

Maintenance Bypass Switch Part. LE09522AA-08/16-01 GF 3 109 53 Maintenance Bypass Switch Installation Manual 3 109 53 Maintenance Bypass Switch EN FR ENGLISH 3 2 3 109 53 Maintenance Bypass Switch Index 1 Introduction 4 1.1 Overview

More information

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual On Line UPS LUC 1000E / LUC 2000E / LUC 3000E User Manual Save This Manual Please read this manual carefully prior to storage, installation, wiring, operation and maintenance of the UPS. This manual contains

More information

Uninterruptible Power Supplies

Uninterruptible Power Supplies S4K2U-C and S4K2U-5C Industrial On-Line UPS The new SolaHD S4KC is a single-phase, on-line (doubleconversion) UPS system available in 700-3000VA, 120V and 230V. On-Line design means zero transfer time

More information

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SUT20K Highlights On-line double-conversion topology, VFI operation

More information

OWNERS MANUAL JANUARY 2007 ISO

OWNERS MANUAL JANUARY 2007 ISO Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com OWNERS MANUAL JANUARY

More information

DC to AC Power Inverters

DC to AC Power Inverters Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com ISO 9001:2000 Certified

More information

DC to AC Power Inverters

DC to AC Power Inverters Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121114C OWNERS

More information

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9 USER MANUAL 1 CONTENTS 1. INTRODUCTION... 1 2. SAFTY INSTRUCTION... 3 3. CABLE CONNECTION... 4 4. SYSTEM DESCRIPTION... 5 5. OPERATION... 9 6. TROUBLE SHOOTING GUIDE... 25 7. OPERATION MODES..... 27 8.

More information

2 Uninterruptible Power Systems

2 Uninterruptible Power Systems 2 Uninterruptible Power Systems S4K2U-C and S4K2U-5C Industrial On-Line UPS The new SolaHD S4KC is a single-phase, on-line (doubleconversion) UPS system available in 700-3000VA, 120V and 230V. On-Line

More information

WF-5100 Series True Sine Wave Inverters

WF-5100 Series True Sine Wave Inverters Operator s Manual WF-5100 Series True Sine Wave Inverters WF-9900 Series WF-5118 WF-5120 ( The Inverter model number is located on the label on top of the enclosure) Distributed in the U.S.A. and Canada

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be

More information

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual USER MANUAL IPS home inverters with UPS function Suitable for UPS: - IPS300-SIN - IPS300-SIN-WM - IPS300-SIN-DC - IPS600-SIN - IPS600-SIN-WM - IPS600-SIN-DC - IPS1000-SIN - IPS1000-SIN-DC - IPS1600-SIN

More information

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function. User Manual Design Features: 1. PFC function. except BC-1215HT / BC-2407HT 2. LCD remote control. BC-1215HT / BC-2407HT 3. Battery temperature sensor function. 4. Tri-LED color indicator for different

More information

CTFRP Series Power Supplies

CTFRP Series Power Supplies CTFRP Series Power Supplies Ferroresonant Non-Standby Power Supplies User Manual Myers Power Products 6/2013 CTFRP Series Manual Chapter 1 General Information The Myers CTFRP Series Power Supply provides

More information

Installation and Operation Back-UPS BX550CI-CN

Installation and Operation Back-UPS BX550CI-CN Installation and Operation Back-UPS BX550CI-CN Safety and General Information This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with fluids, or where there

More information

Freedom egen System End-of- Line Functional Checklist

Freedom egen System End-of- Line Functional Checklist U Freedom egen System End-of- Line Functional Checklist 976-0361-01-01 Rev A April 2018 DANGER RISK OF FIRE, ELECTRIC SHOCK, EXPLOSION, AND ARC FLASH This checklist is in addition to, and incorporates

More information

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9 SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9 MODEL NUMBER: AL-84111 Specifications OUTPUT Output Volt Amp Capacity (VA) 2200 Output kva Capacity

More information

SED2 Variable Frequency Drive Electronic Bypass (E-Bypass) Options

SED2 Variable Frequency Drive Electronic Bypass (E-Bypass) Options SED2 Variable Frequency Drive Electronic Bypass (E-Bypass) Options Product Description The SED2 Electronic Bypass (E-Bypass) Options are companion packages for the family of SED2 Variable Frequency Drives

More information

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS NB 0811 - NB 1511 NB 0831 - NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS LEN.MAN.UPS.069 Rev.2.00/2002 CONTENTS Safety Instructions 1 Introduction 3 2.1 FEATURE 3 2.2 UPS modules 4 How the UPS works 5 3.1

More information

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE MODEL A96 SERIES 130Vdc Switchmode Utility Rectifier / Battery Charger Used with LaMarche Power Cage CPN112138 ECN/DATE ISSUE DATE: ECN 17010-12/05 106 BRADROCK DRIVE DES PLAINES, IL. 60018-1967 (847)

More information

Battery Unit BHM60PC/BHM100PC Instruction Manual

Battery Unit BHM60PC/BHM100PC Instruction Manual Battery Unit BHM60PC/BHM100PC Instruction Manual For the use of UPS BH60PCW/BH100PCW This manual contains important information regarding the safe use of the BHM60PC/BHM100PC for the Backup Power Supply

More information

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA Inventory Safety and General Information bu001c This unit is intended for indoor use only. Do not operate this unit in direct sunlight,

More information

02/15/01. Powerware User s Guide VA.

02/15/01. Powerware User s Guide VA. 02/15/01 Powerware 3115 User s Guide 300-650 VA www.powerware.com Powerware is a registered trademark of Powerware Corporation. Copyright 1999 Powerware Corporation, Raleigh, NC. All rights reserved. No

More information

Installation and user manual 5SC 500 5SC 750 5SC SC SC 500G 5SC 750G 5SC 1500G ENGLISH. Copyright 2013 EATON All rights reserved.

Installation and user manual 5SC 500 5SC 750 5SC SC SC 500G 5SC 750G 5SC 1500G ENGLISH. Copyright 2013 EATON All rights reserved. ENGLISH Installation and user manual SC 00 SC 70 SC 000 SC 00 SC 00G SC 70G SC 00G Copyright 03 EATON All rights reserved. Service and support: Call your local service representative Page IMPORTANT SAFETY

More information

Operating Instructions for PAC800 Battery Charger

Operating Instructions for PAC800 Battery Charger Operating Instructions for PAC800 Battery Charger General Safety The charger may only be used for the specified battery types. This battery charger is supplied with pre-set charging curves that are adapted

More information

WF-5110R True Sine Wave Inverter

WF-5110R True Sine Wave Inverter Operator s Manual WF-5110R True Sine Wave Inverter WF-9900 Series WF-5110R ( The Inverter model number is located on the label on top of the enclosure) Distributed in the U.S.A. and Canada by ARTERRA DISTRIBUTION

More information

Installation and Operation Manual Back-UPS BR1000-CH

Installation and Operation Manual Back-UPS BR1000-CH Installation and Operation Manual Back-UPS BR1000-CH Complete, sign and return the Quality Assurance card or register the product online at www.apc.com. Safety This unit is intended for indoor use only.

More information

1. INTRODUCTION. Features:

1. INTRODUCTION. Features: 1. INTRODUCTION This series is a compact and fully pure sinewave line interactive UPS, and it designs for critical application and environment, such as desktops, servers, workstations, and other networking

More information

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software APC's Back-UPS ES series is now "greener" than ever. The ES 350 utilizes an ultra-efficient design that consumes less power

More information

HOYMILES MICRO-IVERTER MI-250

HOYMILES MICRO-IVERTER MI-250 HOYMILES MICRO-IVERTER MI-250 TECHNICAL MANUAL CONTENTS INTRODUCTION... 3 SAFETY... 4 SYMBOL ILLUSTRATION... 4 INSTALLATION WARNINGS... 5 PREPARE FOR INSTALLING... 6 TRANSPORT AND INSPECT... 6 CHECK INSTALLATION

More information

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING Matrix AP 400V 690V INSTALLATION GUIDE FORM: MAP-IG-E REL. May 2017 REV. 002 2017 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.

More information

OBAE, OBAEXU, ON BOARD Battery Chargers

OBAE, OBAEXU, ON BOARD Battery Chargers C O R P O R A T IO N O P E R A T I N G I N S T R U C T I O N S OBAE, OBAEXU, ON BOARD Battery Chargers INTRODUCTION: The OBAE line of chargers are designed for the permanent installation on battery powered

More information

Uninterruptible Power System

Uninterruptible Power System USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency UPS 1 st Edition Uninterruptible

More information

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 120015D OWNERS

More information

Galaxy VX. 480 V UPS System Technical Specifications 07/

Galaxy VX. 480 V UPS System Technical Specifications 07/ Galaxy VX Technical Specifications 07/2017 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS referred to in this

More information

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 480 Volts, 60Hz. Page 1 of 14. April 15, 2010: updated capacitor UL File number)

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 480 Volts, 60Hz. Page 1 of 14. April 15, 2010: updated capacitor UL File number) POWER QUALITY INSTRUCTION MANUAL Type SWF Sine Wave Filters 480 Volts, 60Hz April 15, 2010: updated capacitor UL File number) Page 1 of 14 Contents 1. Introduction & SAFETY 2. Theory of operation 3. Advantage

More information

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Match 19 GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19 UPS. Match 19" Uninterruptible Power Supply 700-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com

More information

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL Important Safety Information Before installing UPS EN-1000/ EN-2000, please read the operating instructions carefully. Special attention

More information

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS. INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS. Before installing and/or using this product, please check for any visual damage of the enclosure, power

More information

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY 1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY CONTENTS Warranty 2 Introduction 3 Environmental protection 3 Specifications 3 General safety warnings and instructions 4 Important safety instructions

More information

OWNERS MANUAL JANUARY 2007 ISO

OWNERS MANUAL JANUARY 2007 ISO Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121231B OWNERS

More information

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC User s Manual K01-C000304-02 2 TABLE OF CONTENTS 1 IMPORTANT SAFETY INSTRUCTIONS..4 2 INSTALLATION....5 2-1 Unpacking...5

More information

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL U P S Uninterruptible Power System Line-Interactive Network UPS 800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

More information