Protector XL Floor-Mounted Laboratory Hoods Features & Benefits

Size: px
Start display at page:

Download "Protector XL Floor-Mounted Laboratory Hoods Features & Benefits"

Transcription

1 Protector XL FLOOR-MOUNTED LAORATORY HOODS

2 Protector XL Floor-Mounted Laboratory Hoods Features & enefits Protector XL Floor-Mounted Laboratory Hoods accommodate laboratory procedures that require over-sized equipment or maximum work area. Users with applications requiring distillation racks, extraction apparatus or large drums and carboys benefit from the increased height these hoods provide. Protector XL Floor-Mounted Laboratory Hoods are supplied in three depths and several widths up to 16 feet. Depending on the model, these hoods have vertical-rising or horizontal-sliding sashes. Front and side panels may be easily removed for lamp replacement and access to electrical supply connections. ETL-listed. Hoods carry the ETL mark signifying that they are certified to UL / , UL 1805 and AN/SA 22.2 No Durable and attractive exterior is glacier white, dry powder epoxycoated steel. Tempered safety glass sashes are anti-racking for smooth operation. Hoods feature either vertical-rising or horizontal-sliding sashes depending on hood model. When fully open, vertical-rising sashes do not extend above the hood. Adjustable baffles provide a uniform face velocity pattern across the sash opening of the hood. Fluorescent lighting illuminates the interior. The high-efficiency, instant start, T8 fluorescent lights are located outside the hood interior for corrosion-resistance and easy replacement. ontact Labconco for ordering information on explosionproof lighting. Pre-wired electrical components. Fluorescent lights and switches are factory-wired to the hood s single point junction box. One electrical duplex receptacle is factory-wired on fixtured models. Each hood is factoryprepared for up to four electrical duplexes and an airflow monitor. Interior working dimensions are offered in standard and larger depths. Working depths include 30", 36" and 48". Performance tested to ASHRAE y-pass airflow design ensures relatively stable face velocities. olor-coded service fixtures for gas, air, water, vacuum and other services have remote controls for use regardless of the sash position. Two service fixtures are pre-plumbed on fixtured models. Each hood is factory prepared for up to eight service fixtures (four on each side). Service access panels allow easy accessibility to plumbing from the front and inside of the hood. hemical-resistant, fiberglassreinforced composite panel liner surpasses all national codes for flame spread and has a bright white surface for excellent light reflectivity. 2

3 Protector XL Floor-Mounted Laboratory Hoods 6' Protector XL Floor-Mounted Laboratory Hood lower and ductwork must be ordered separately. Fixtured models feature: Two pre-plumbed service fixtures with forged brass valves, lower right side with brass tubing for gas and lower left side with copper tubing for cold water. omponents for converting either or both fixtures to air and vacuum are provided. Inlet tubing is not provided. One pre-wired 115 volt, 20 amp electrical duplex receptacle on lower right side. Requires Ductwork and lower 8' Protector XL Floor-Mounted Laboratory Hood lower and ductwork must be ordered separately. All models require (not included): Remote lower. Request lowers ooklet. Ductwork. Request lowers ooklet. All models feature: y-pass airflow design. Glacier white, dry powder epoxy-coated steel exterior. hemical-resistant, fiberglass-reinforced composite panel liner and adjustable upper and lower baffles with flame spread less than 25 per ASTM E-84. Removable front and side panels and exterior and interior service access panels for access to plumbing and electrical wiring. Pre-wired T8 fluorescent lighting, light and blower switches for 115 volt, 60 Hz operation. Shipped in multiple sections: top, bottom and sashes. Epoxy-coated stainless steel, 12.81" ID exhaust connection(s). 4', 5', 6' and 8' models feature: Two 3/16" thick tempered safety glass vertical-rising sashes framed with PV (4', 5' and 6' models) or epoxy-coated aluminum (8' models). Sashes do not extend above the hood when fully open. 8', 10', 12' and 16' models feature: Four 3/16" thick tempered safety glass horizontal-sliding sashes with epoxycoated aluminum frames and sash tracks. All models conform to the following regulations and standards: SEFA NFPA ASTM E84-09 ASHRAE ANSI Z UL / AN/SA 22.2 No UL 1805 Optional accessories for on-site installation include: Service Fixture Kits. See page 7. Side-Mount Oval upsink. See back cover. Electrical Duplex Kits. See back cover. Guardian Airflow Monitor Kits. See back cover. ontact Labconco at or for ordering information on ceiling enclosure and rear finish panel kits, fire extinguishers, explosion-proof lighting, solid epoxy floors, tissue screens and distillation grids; and for blower sizing assistance. Heights of switches, electrical receptacle and service fixtures meet requirements of ADA. 3

4 Ordering Information 4', 5', 6' and 8' Protector XL Floor-Mounted Laboratory Hoods with vertical-rising sashes Exterior Interior 12.81" (32.5 cm) Shipping Nominal atalog Depth (A) Depth () ID Exhaust Fluorescent Service Electrical Weight Width Number inches/cm inches/cm ollar(s) Lamps Fixtures Duplex lbs./kg 4 Feet / / ea. 25 watt / / / ea. 25 watt / / / ea. 25 watt /338 5 Feet / / ea. 32 watt / / / ea. 32 watt / / / ea. 32 watt /390 6 Feet / / ea. 32 watt / / / ea. 32 watt / / / ea. 32 watt /447 8 Feet / / ea. 25 watt / / / ea. 25 watt / / / ea. 25 watt /556 Nominal Total Exhaust FM and Static Pressure with sashes 50% open Width 100 fpm S.P. 80 fpm S.P. 4 Feet " " 5 Feet " " 6 Feet " " 8 Feet " " Ordering Information 8', 10', 12' and 16' Protector XL Floor-Mounted Laboratory Hoods with horizontal-sliding sashes Exterior Interior 12.81" (32.5 cm) Shipping Nominal atalog Depth (A) Depth () ID Exhaust Fluorescent Service Electrical Weight Width Number inches/cm inches/cm ollar(s) Lamps Fixtures Duplex lbs./kg 8 Feet / / ea. 25 watt / / / ea. 25 watt / / / ea. 25 watt / Feet / / ea. 32 watt / / / ea. 32 watt / / / ea. 32 watt / Feet / / ea. 32 watt / / / ea. 32 watt / / / ea. 32 watt / Feet / / ea. 25 watt / / / ea. 25 watt / / / ea. 25 watt /966 Nominal Sashes Total Exhaust FM and Static Pressure Width Open 100 fpm S.P. 80 fpm S.P. 8 Feet " " 10 Feet " " 12 Feet " " 16 Feet " 4

5 Dimensional Data 4', 5', 6' and 8' Protector XL Floor-Mounted Laboratory Hoods with vertical-rising sashes 4.91" (12.5 cm) 2.27" (5.8 cm) 4.91" 2.27" 12.81" ID Exhaust ollar TOP 4', 5', 6' 2.50" (6.4 cm) dia. Service Fixture Supply Holes F 12.81" (32.5 cm) ID Exhaust ollars TOP (8') 10.53" 2.50" dia. Service Fixture Supply Holes E Single Point Internal Junction ox 10.53" (26.7 cm) D Single Point Internal Junction ox A* * * D* E* F* H* 4' Hood (121.9) (97.2) (61.0) (99.6) (76.2) (149.4) (121.9) (97.2) (61.0) (114.8) (91.4) (149.4) (121.9) (97.2) (61.0) (145.3) (121.9) (149.4) 5' Hood (152.4) (127.6) (76.2) (99.6) (76.2) (149.4) (152.4) (127.6) (76.2) (114.8) (91.4) (149.4) (152.4) (127.6) (76.2) (145.3) (121.9) (149.4) 6' Hood (182.9) (158.1) (91.4) (99.6) (76.2) (149.4) (182.9) (158.1) (91.4) (114.8) (91.4) ( (182.9) (158.1) (91.4) (145.3) (121.9) (149.4) 8' Hood (243.8) (219.1) (61.0) (99.6) (76.2) (121.9) (149.9) (243.8) (219.1) (61.0) (114.8) (91.4) (121.9) (149.9) (243.8) (219.1) (61.0) (145.3) (121.9) (121.9) (149.9) *Inches (centimeters) A D Fluorescent Lights 4.19" (10.6 cm) 68.15" (173.1 cm) Viewing Height to Floor H Sash Opening Front Access Panel (one on each side) Service Fixture (one on each side) 115 Volt, 20 Amp Duplex Electrical Receptacle 2.00" (5.1 cm) Interior Access Panels 15.00" (38.1 cm) Upper abinet Lower ase E 36.00" 77.00" (195.6 cm) 84.00" (213.4 cm) 7.00" (17.8 cm) 95.00" (241.3 cm) Sash Frame to affle FRONT 2.50" (6.4 cm) dia. Ser Service Fixture Supply Holes SIDE ontact Labconco at or or visit for detailed AutoAD drawings. 5

6 Dimensional Data 8', 10', 12' and 16' Protector XL Floor-Mounted Laboratory Hoods with horizontal-sliding sashes A* * * D* E* F* G* H* 8' Hood (243.8) (219.1) (61.0) (99.6) (76.2) (121.9) (57.2) (109.9) (243.8) (219.1) (61.0) (114.8) (91.4) (121.9) (57.2) (109.9) (243.8) (219.1) (61.0) (145.3) (121.9) (121.9) (57.2) (109.9) 4.91" (12.5 cm) 2.27" (5.8 cm) 2.50" (6.4 cm) dia. Service Fixture Supply Holes F 12.81" (32.5 cm) ID Exhaust ollars TOP 8', 10', 12' 10.53" (26.7 cm) D Single Point Internal Junction ox 10' Hood (304.8) (280.0) (88.9) (99.6) (76.2) (127.0) (72.4) (140.3) (304.8) (280.0) (88.9) (114.8) (91.4) (127.0) (72.4) (140.3) (304.8) (280.0) (88.9) (145.3) (121.9) (127.0) (72.4) (140.3) 12' Hood (365.8) (341.0) (104.1) (99.6) (76.2) (157.5) (87.6) (170.8) (365.8) (341.0) (104.1) (114.8) (91.4) (157.5) (87.6) (170.8) (365.8) (341.0) (104.1) (145.3) (121.9) (157.5) (87.6) (170.8) 16' Hood (487.7) (462.9) (61.0) (99.6) (76.2) (121.9) (118.1) (231.8) (487.7) (462.9) (61.0) (114.8) (91.4) (121.9) (118.1) (231.8) (487.7) (462.9) (61.0) (145.3) (121.9) (121.9) (118.1) (231.8) *Inches (centimeters) Four ollars 4.91" (12.5 cm) 2.27" (5.8 cm) F 12.81" (32.5 cm) ID Exhaust ollars 2.50" (6.4 cm) dia. Service Fixture Supply Holes F 12.81" (32.5 cm) ID Exhaust ollars 10.53" (26.7 cm) D Single Point Internal Junction ox TOP (16') A Fluorescent Lights D 4.19" (10.6 cm) Front Access Panel (one on each side) 15.00" 7.00" (17.8 cm) 68.15" (173.1 cm) Viewing Height to Floor H Max Opening G Door Width Service Fixture (one on each side) 115 Volt, 20 Amp Duplex Electrical Receptacle 2.00" (5.1 cm) Interior Access Panels Upper abinet Lower ase E 77.00" (195.6 cm) 36.00" (91.4 cm) 84.00" (213.4 cm) 95.00" (241.3 cm) Sash Frame to affle FRONT SIDE ontact Labconco at or or visit for detailed AutoAD drawings. 6

7 Accessories Standard Service Fixture Kits For mounting on the left or right side of the Protector XL Floor-Mounted Laboratory Hood. Each kit includes one remotely-controlled service fixture with valve and 0.25" diameter tubing, color-coded fixture knob and color-coded hose connector. Inlet tubing is not included. Shipping weight 4 lbs. (1.8 kg) atalog # Kit Tubing Valve Knob/onnector Max. Max. Working olor Flow Rate Pressure ** old Water (W) opper rass Green 3.5 GPM (13.2 LPM) 40 psi Air (AIR) opper rass Orange 23.7 FM 40 psi Vacuum (VA) opper rass Yellow 8.6 FM 14.7 psi Gas (GAS) rass rass lue 29.0 FM (441 TU/sec) 40 psi Argon (ARG) opper rass Gray 20.2 FM 40 psi Hot Water (HW) opper rass Red 3.5 GPM (13.2 LPM) 40 psi Deionized/ Stainless Nickel-Plated & White 3.5 GPM (13.2 LPM) 40 psi Distilled Water (DI) Steel Stainless Steel Steam (STM) opper rass lack 0.5 LM/min 40 psi Nitrogen (NIT) opper rass rown 24.1 FM 40 psi * Oxygen (OXY) opper rass with Light Green 22.6 FM 40 psi Oxygen- ompatible Lubricant old Water Gooseneck Fixture Kits For mounting on the left or right side of any Protector XL Floor-Mounted Laboratory Hood with 30" interior depth. Each kit includes one remotely-controlled gooseneck with brass valve and 0.375" diameter copper tubing and green fixture knob. Inlet tubing is not included. ontact Labconco for ordering information on Gooseneck Fixture Kits for Protector Hoods with interior depths of 36" or 48". Shipping Weight 10 lbs. (4.5 kg) atalog # Kit Description Max. Flow Rate Max. Working Pressure ** old Water (W) For Hoods with Interior 3.5 GPM (13.2 LPM) 40 psi Gooseneck Depths of 24" to 30". Includes green epoxy-coated brass rigid/swivel gooseneck. Hot and old Water Mixing Gooseneck Fixture Kit For any Protector XL Floor-Mounted Laboratory Hood with interior depth of 24" to 30". Each kit includes one remotelycontrolled, white epoxy-coated, brass rigid/swivel gooseneck with brass valve and 0.25" diameter copper tubing, one green fixture knob and one red fixture knob. Inlet tubing is not included. ontact Labconco for ordering information on Gooseneck Fixture Kits for Protector Hoods with interior depths of 36" or 48". Shipping weight 11 lbs. (5.0 kg) atalog # Kit Description Max. Flow Rate Max. Working Pressure ** Hot (HW) and old Water (W) For Hoods with Interior 3.5 GPM (13.2 LPM) 40 psi Mixing Gooseneck Depths of 24" to 30" Deionized/Distilled Water Gooseneck Fixture Kit For mounting on the left or right side of any Protector XL Floor-Mounted Laboratory Hood with 30" interior depth. Each kit includes one remotely-controlled, gray PV rigid gooseneck with stainless steel valve and 0.25" diameter tubing and white fixture knob. ontact Labconco for ordering information on Gooseneck Fixture Kits for Protector Hoods with interior depths of 36" or 48". Inlet tubing is not included. Shipping weight 10 lbs. (4.5 kg) atalog # Kit Description Max. Flow Rate Max. Working Pressure ** Deionized/Distilled Water For Hoods with Interior 3.5 GPM (13.2 LPM) 40 psi (DW) Gooseneck Depths of 24" to 30" GPM=gallons per minute LPM=liters per minute FM=cubic feet per minute TU/sec=ritish thermal unit per second LM/min= pounds mass per minute *WaterSaver **Maximum allowable pressure is 200 psi with a working pressure of 40 psi. Requires 1.375" dia. drill hole in liner. 7

8 Accessories Side-Mount Oval Polypropylene upsink Mounts on side wall of Protector XL Floor-Mounted Hoods. 6" x 3" cupsink. 1.5" NPSM thread. Requires a 1.875" diameter drilled hole in liner. Shipping weight 4 lbs. (1.8 kg) National Pipe Straight Mechanical Duplex Electrical Receptacle Kits For mounting in left or right side of any 4', 5', 6', 7' or 8' Protector XL Floor-Mounted Laboratory Hood. Each kit includes duplex electrical receptacle, wiring, junction box and receptacle cover plate. ontact Labconco for ordering information on Duplex Electrical Receptacle Kits for Protector Hoods with widths of 10', 12' or 16'. atalog # Kit For Hood with exterior widths: Shipping Wt. lbs./kg volts, 20 amps A 4', 5', 6' and 8' 4/ volts, 20 amps A, GFI 4', 5', 6' and 8' 4/ volts, 20 amps A 4', 5', 6' and 8' 4/1.8 Guardian 1000 Digital Airflow Monitor Kits Monitor and alert the operator to low airflow conditions. Include face plate with circuit board, electrical power pack, airflow hose and flow hose adapter. LD displays actual airflow in fpm or m/sec from 0 to 999 fpm (0 to 5.0 m/s). Audible/visual alarm alerts user to sustained low velocity condition. alibration instructions displayed on LD. LED lights display red for alarm, yellow for caution, green for normal. Include temperature-compensated sensor, external alarm, night setback and alarm mute functions. UL and E listed. For installation in a factory-prepared cutout on upper portion of right fixture panel. ontact Labconco for ordering information on an optional factory-prepared RS-485 port for Modbus RTU communication. atalog # Description For use with: Shipping Wt. lbs./kg volts, 60 Hz Protector XL Floor-Mounted Laboratory Hood 6/ * 230 volts, 50 Hz Protector XL Floor-Mounted Laboratory Hood 6/2.7 Guardian 500 Airflow Monitor Kits Monitor and alert the operator to low airflow conditions. Include face plate with circuit board, electrical power pack, vinyl tubing and airflow tube adapter. From the monitor s face plate, the user can easily select and calibrate a setpoint between 30 and 250 fpm using a velocity meter and a screwdriver. A green LED glows to indicate safe when airflow is greater than the low setpoint. A red LED flashes to indicate low when airflow is below the low setpoint. An amber LED flashes when the sash is raised above the maximum safe working opening. An audible alarm sounds (and can be muted) when under low and sash high conditions. Include night setback, external alarm and alarm mute functions. For installation in a factory-prepared cutout on upper portion of right fixture panel. atalog # Description For use with Protector Hood: Shipping Wt. lbs./kg volts, 60 Hz Protector XL Floor-Mounted Laboratory Hood 6/ * 230 volts, 50 Hz Protector XL Floor-Mounted Laboratory Hood 6/2.7 Labconco orporation 8811 Prospect Avenue Kansas ity, Missouri FAX: labconco@labconco.com Home Page: ontact Labconco at or for ordering information on ceiling enclosure and rear finish panel kits, fire extinguishers, explosion-proof lighting, solid epoxy floors, tissue screens and distillation grids; and for blower sizing assistance by Labconco orporation Printed in the U.S.A. Product design subject to change without notice /12-James-1M-R1

Accessories Standard Service Fixture Kits

Accessories Standard Service Fixture Kits Standard Service Fixture Kits For mounting on the left or right side of any Protector Premier, XStream, XL, XLE or PVC Hood. Each kit includes one remotely-controlled service fixture with valve and 0.25"

More information

Requires Ductwork and Blower

Requires Ductwork and Blower 6' Protector XStream Laboratory Hood 9840600 is shown with SpillStopper Work Surface 9849800, Protector Acid Storage Cabinet 9901100 and Protector Standard Storage Cabinet 9900100. Requires Ductwork and

More information

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector Protector XStream Laboratory Hood 9840600 is shown with SpillStopper Work Surface 9849800, Protector Acid Storage Cabinet 9901100 and Protector Standard Storage Cabinet 9900100. Protector XStream Laboratory

More information

Protector Special Application Hoods Laboratory Hoods for Radioisotope, Perchloric Acid and Acid Digestion Use Fiberglass 28, Demonstration and Canopy

Protector Special Application Hoods Laboratory Hoods for Radioisotope, Perchloric Acid and Acid Digestion Use Fiberglass 28, Demonstration and Canopy Protector Special Application Hoods Laboratory Hoods for Radioisotope, Perchloric Acid and Acid Digestion Use Fiberglass 28, Demonstration and Canopy Hoods A Applications involving perchloric acid, acid

More information

Protector XStream Laboratory Hoods

Protector XStream Laboratory Hoods High Performance Hood offers enhanced containment combined with energy savings. With its unsurpassed containment and substantial energy savings potential, the patented* Protector XStream Fume Hood delivers

More information

Protector. Storage Cabinets, Base Stands & Fume Hood Accessories

Protector. Storage Cabinets, Base Stands & Fume Hood Accessories Protector Storage Cabinets, Base Stands & Fume Hood Accessories Storage Cabinets & Base Stands Selection Guide Complete your installation of a Labconco fume hood or enclosure with a Labconco base cabinet

More information

Laboratory Fume Hoods & Enclosures

Laboratory Fume Hoods & Enclosures Laboratory Fume Hoods & Enclosures Protector ClassMate Laboratory Hoods Fiberglass 30 Laboratory Hoods Protector Demonstration Hoods Basic Laboratory Hoods Protector XVS Ventilation Stations Canopy Hoods

More information

Protector. Storage Cabinets, Base Stands & Fume Hood Accessories

Protector. Storage Cabinets, Base Stands & Fume Hood Accessories Protector Storage Cabinets, Base Stands & Fume Hood Accessories Storage Cabinets & Base Stands Selection Guide Complete your installation of a Labconco fume hood or enclosure with a Labconco base cabinet

More information

Laboratory Fume Hoods & Enclosures

Laboratory Fume Hoods & Enclosures Laboratory Fume Hoods & Enclosures Protector ClassMate Laboratory Hoods Fiberglass 30 Laboratory Hoods Protector Demonstration Hoods Basic Laboratory Hoods Protector XVS Ventilation Stations Canopy Hoods

More information

Protector Demonstration Hoods

Protector Demonstration Hoods Protector Demonstration Hoods Protector Demonstration Hoods are low profile, light-duty fume hoods designed to provide close observation of procedures during educational demonstrations. ll models feature:

More information

General Purpose Walk-In Fume Hood

General Purpose Walk-In Fume Hood General Purpose Walk-In Fume Hood with Vertical Rising Sash Available Models: Open By-Pass Restricted By-Pass Auxiliary Air Available Option: Adjustable Baffles Air Flow and Static Pressure Alarms Service

More information

General Purpose Walk-In Fume Hood

General Purpose Walk-In Fume Hood General Purpose Walk-In Fume Hood with Vertical Rising Sash Available Models: Open By-Pass Restricted By-Pass Auxiliary Air Available Option: Adjustable Baffles Air Flow and Static Pressure Alarms Service

More information

Supreme AirLV- FUME HOODS. KEWAUNEE encouraging new discovery LOW CONSTANT VOLUME

Supreme AirLV- FUME HOODS. KEWAUNEE encouraging new discovery LOW CONSTANT VOLUME Supreme AirLV- LOW CONSTANT VOLUME FUME HOODS KEWAUNEE encouraging new discovery Supreme Air LV Fume Hood Low Velocity Low Volume Full Access Hold-Open Catch for set-up sash position Flush Mounted Convergent

More information

SECTION LABORATORY FUME HOODS UNIFLOW LE SERIES

SECTION LABORATORY FUME HOODS UNIFLOW LE SERIES SECTION 11610.1 LABORATORY LE FUME HOODS UNIFLOW LE SERIES REVISED AUGUST 2, 2013 LABORATORY FUME HOODS UNIFLOW LE SERIES PART 1 GENERAL 1.00 SUMMARY A. Section Includes: 1. Laboratory Fume Hoods B. Related

More information

Purifier Logic Class II Biosafety Cabinets FEATURES & BENEFITS

Purifier Logic Class II Biosafety Cabinets FEATURES & BENEFITS Purifier Logic Class II Biosafety Cabinets FEATURES & BENEFITS Optional 254 nm UV lamp Contain-Air Negative Pressure Channel Bright, glare-free fluorescent lighting Fully-closing, counterbalanced tempered

More information

REDISHIP Biosafety Cabinets, Fume Hoods and Balance Enclosures

REDISHIP Biosafety Cabinets, Fume Hoods and Balance Enclosures REDISHIP Biosafety Cabinets, Fume Hoods and Balance Enclosures Made in the USA. Select the Right Laboratory Ventilation Product Fume hoods, biological safety cabinets and ventilation enclosures protect

More information

F. VAV hoods shall have a restricted bypass plate.

F. VAV hoods shall have a restricted bypass plate. 1.01 SUMMARY A. Section Includes: 1. Laboratory fume hoods. B. Related Sections: 1. Section 6500 Laboratory casework 2. Section 15 Mechanical: Furnishing and installation of plumbing utilities and final

More information

LABORATORY FUME HOODS OF 5

LABORATORY FUME HOODS OF 5 SECTION 11 5313 - LABORATORY FUME HOODS AND RELATED PRODUCTS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Bench-top laboratory fume hoods. 2. Service fittings and electrical service fitting inside

More information

Protector Controlled Atmosphere Glove Boxes

Protector Controlled Atmosphere Glove Boxes Protector Controlled Atmosphere Glove Boxes I N T R O D U C T I O N Protector Controlled Atmosphere Glove Boxes provide a leak-tight environment for work with contaminationsensitive materials. Organometallic

More information

Pre-Wired and Pre-Piped

Pre-Wired and Pre-Piped Pre-Wired and Pre-Piped Pre-Wired All Supreme Air Fume Hoods may be Pre-Wired at the factory. Pre-Wired hoods are wired using flexible metallic conduit to a single junction box located at the top of the

More information

Laboratory Carts & Benches

Laboratory Carts & Benches Laboratory Carts & Benches Labconco Laboratory Carts and Benches fit in every lab. These versatile carts have endless uses from transporting equipment and supplies to providing auxiliary bench space. Labconco

More information

Protector Echo Filtered Fume Hoods

Protector Echo Filtered Fume Hoods Protector Echo Filtered Fume Hoods Labconco has combined its patented* fullyfeatured, containment-enhancing Protector Hood design with Erlab s GreenFumeHood (GFH) Filtration Technology to deliver a multi-use

More information

Labconco 48, 60, and 72 Hoods

Labconco 48, 60, and 72 Hoods Labconco 48, 60, and 72 Hoods PROTECTOR LABORATORY HOODS INSTRUCTION MANUAL Model Nos. Remote Blower Integral Blower Style Style 48705 60705 72705 48713 60713 72713 48707 60707 72707 48714 60714 72714

More information

Supreme Air Venturi KEWAUNEE. Laboratory Fume Hoods. encouraging new discovery...worldwide

Supreme Air Venturi KEWAUNEE. Laboratory Fume Hoods. encouraging new discovery...worldwide Supreme Air Venturi Laboratory Fume Hoods KEWAUNEE encouraging new discovery...worldwide VENTURI Laboratory Fume Hoods Unparalleled Venturi enhanced containment technology High Performance/Energy Efficient

More information

FUME HOOD SELECTION GUIDE

FUME HOOD SELECTION GUIDE FUME HOOD SELECTION GUIDE FUME HOOD SELECTION GUIDE Laboratory fume hoods are one of the most vital pieces of safety equipment in a working laboratory. Fume hoods are designed to safely exhaust dangerous

More information

PRECISE. Glove Boxes

PRECISE. Glove Boxes PRECISE Glove Boxes PRECISE Basic Glove Boxes All models feature: One-piece molded, medium-density polyethylene shell. Dry powder epoxy-coated steel superstructure. 1/4" thick laminated safety glass viewing

More information

Protector Airo Filtered Fume Hoods

Protector Airo Filtered Fume Hoods PROTECTOR OR AIRO FILTERED FUME HOODS Protector Airo Filtered Fume Hoods If you have robust chemical applications requiring a fume hood but have low ceiling height and no means to duct to the outside,

More information

BMC. Laboratory Fume Hoods SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION M E M B E R

BMC. Laboratory Fume Hoods SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION M E M B E R BMC Laboratory Fume Hoods M E M B E R SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION Table of Contents Airfoil ADA Fume Hoods...12 ADA Fume Hood Assemblies...13 Add Air Fume Hoods...10 Add Air Fume

More information

Supreme Air Fume Hood Option Availability

Supreme Air Fume Hood Option Availability Supreme Air Fume Hood Option Availability Options V05 V06 V07 V15 V16 V25 V26 Kemglass Liner ( 1 /4") G KMER Liner ( 1 /4") K Type 316L Stainless Steel Liner (16 ga) L Type 304L Stainless Steel Liner (16

More information

Supreme Air. Fume Hoods KEWAUNEE LABORATORY. encouraging new discovery

Supreme Air. Fume Hoods KEWAUNEE LABORATORY. encouraging new discovery Supreme Air LABORATORY Fume Hoods KEWAUNEE encouraging new discovery Stainless Steel H05 Fume Hood with Vertical Rising Sash LV05 Low Constant Volume Fume Hood Supreme Air Fume Hoods Kewaunee s Fume Hood

More information

Appendix C: Biosafety Cabinet Specifications C-2. Product Service

Appendix C: Biosafety Cabinet Specifications C-2. Product Service Appendix C: Biosafety Cabinet Specifications C-2 102 Appendix C: Biosafety Cabinet Specifications C-3 103 Appendix C: Biosafety Cabinet Specifications C-4 104 Appendix C: Biosafety Cabinet Specifications

More information

Protector ClassMate Laboratory Fume Hoods. Models Series Series Series Series Series Series

Protector ClassMate Laboratory Fume Hoods. Models Series Series Series Series Series Series User s Manual Protector ClassMate Laboratory Fume Hoods Models 69704 Series 69705 Series 69706 Series 69714 Series 69715 Series 69716 Series To receive important product updates, complete your product

More information

PROTECTOR. Glove Boxes. Controlled Atmosphere and Multi-Hazard

PROTECTOR. Glove Boxes. Controlled Atmosphere and Multi-Hazard PROTECTOR Glove Boxes Controlled Atmosphere and Multi-Hazard TABLE OF CONTENTS Overview 1-800-821-5525 www.labconco.com Overview...1 Selection Guide...3 Protector Controlled Atmosphere Glove Boxes Introduction...4

More information

Completing Your Fume Removal System

Completing Your Fume Removal System Once a laboratory hood has been selected, the next step is to select the proper blower and ductwork. It is important that these be sized correctly depending on hood size, application, CFM, and distance

More information

PROTECTOR FIBERGLASS ENCLOSURES

PROTECTOR FIBERGLASS ENCLOSURES PROTECTOR FIBERGLASS ENCLOSURES for PCR and Tissue Culture Protector Fiberglass PCR Enclosures Protector Fiberglass Tissue Culture Enclosures Protector Fiberglass PCR & Tissue Culture Enclosures Protector

More information

V05 General Purpose Bench Fume Hood

V05 General Purpose Bench Fume Hood V05 General Purpose Bench Fume Hood with Vertical Rising ash Accessories Included: 4 120 VAC 20 amp GFCI protected duplex receptacles 1 LED light fixture with illumination and color controller 1 Electronic

More information

Laboratory Demonstration Space Located at Price Research Center North Winnipeg. Fume Hoods. ehpricesales.com

Laboratory Demonstration Space Located at Price Research Center North Winnipeg. Fume Hoods. ehpricesales.com Laboratory Demonstration Space Located at Price Research Center North Winnipeg Fume Hoods ehpricesales.com 2 www.ehpricesales.com FUME HOODS Contents Dynamic Bench Fume Hood Features High Performance Fume

More information

Appendix C: Biosafety Cabinet Specifications C-1. Product Service

Appendix C: Biosafety Cabinet Specifications C-1. Product Service Appendix C: Biosafety Cabinet Specifications C-1 Product Service 1-800-522-7658 111 Appendix C: Biosafety Cabinet Specifications C-2 112 Product Service 1-800-522-7658 Appendix C: Biosafety Cabinet Specifications

More information

Refrigerators/Freezers

Refrigerators/Freezers Explosion-Proof, Corrosion-Resistant Refrigerator Flammable Material Storage Refrigerator/Freezer Laboratory Freezer Lab-Line offers a complete line of refrigerators and freezers to accommodate virtually

More information

Protector Laboratory Fume Hoods & Enclosures Overview

Protector Laboratory Fume Hoods & Enclosures Overview Protector Laboratory Fume Hoods & Enclosures Overview Since the manufacture of our first product in 1925, the Kjeldahl Apparatus, Labconco has focused on finding effective ways to remove chemical fumes

More information

User s Manual. LabShield. Laboratory Fume Hoods. Air Foil By-Pass Models: 6714, 6716, ADA Models: 8796, 8798, Demonstration Hood 6725G

User s Manual. LabShield. Laboratory Fume Hoods. Air Foil By-Pass Models: 6714, 6716, ADA Models: 8796, 8798, Demonstration Hood 6725G User s Manual LabShield By CampbellRhea Laboratory Fume Hoods Air Foil By-Pass Models: 6714, 6716, 6718 ADA Models: 8796, 8798, 8800 Demonstration Hood 6725G CampbellRhea 1865 North Market Street Paris

More information

LABORATORY FUME HOODS

LABORATORY FUME HOODS Fume Hoods Fume Hood Applications Laboratory professionals and students across the country, and all over the world, depend on the safety of our hoods. Your protection is our first concern and the fume

More information

General Plumbing Information

General Plumbing Information General Plumbing Information Recommended Supply Line Pressures Service & Rough-in Abbreviations Service Fitting Index Color Coding Gas...0.216 psi Air (Ordinary)...15 psi Air (Air Powered Stirrer Operation)...40

More information

User s Manual. Protector Laboratory Fume Hoods. Premier Models. XL Models

User s Manual. Protector Laboratory Fume Hoods. Premier Models. XL Models User s Manual Protector Laboratory Fume Hoods Premier Models 4871300, 4871400, 4871500, 4871600, 4880000, 4880100, 4880200, 4880300, 4880400 6071300, 6071400, 6071500, 6071600, 6080000, 6080100, 6080200,

More information

Supreme Air Venturi Laboratory Fume Hood Catalog. ehpricesales.com

Supreme Air Venturi Laboratory Fume Hood Catalog. ehpricesales.com Supreme Air Venturi Laboratory Fume Hood Catalog ehpricesales.com VENTURI BENCH FUME HOOD FEATURES GENERAL FEATURES Unparalleled Venturi enhanced containment technology Electromechanical sash stop integrated

More information

Precise Glove Boxes & XPert Weigh Boxes

Precise Glove Boxes & XPert Weigh Boxes Precise Glove Boxes Precise Glove Boxes & XPert Weigh Boxes O V E R V I E W Table of Contents Overview................................................ 3 Selection Guide.........................................

More information

RDM. Laboratory Fume Hoods SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION

RDM. Laboratory Fume Hoods SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION RDM Laboratory Fume Hoods SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION Table of Contents Airfoil ADA Fume Hoods...12 Demonstration Fume Hood...22 ADA Fume Hood Assemblies...13 Drains... 30 SB-MAX-A

More information

AUDIO-VISUAL EQUIPMENT

AUDIO-VISUAL EQUIPMENT 11 52 00 AUDIO-VISUAL EQUIPMENT 1. GENERAL A. Related sections: i. 00 00 13 Designing Learning Environments ii. 11 52 13 Projection Screens iii. 12 56 52 Audio-Visual Equipment iv. 72 41 00 General Audio-Visual

More information

Section Fume Hoods Specifications 6/1/14 LABORATORY FUME HOODS

Section Fume Hoods Specifications 6/1/14 LABORATORY FUME HOODS 1.01 SUMMARY A. Section Includes: Fume hoods LABORATORY FUME HOODS B. Related Sections 1. Division 12 Section - 12345 - Steel Laboratory Casework 2. Division 12 Section - 12346 - Agility Adaptable Furniture

More information

HEMCO. Laboratory Fume HoodsR

HEMCO. Laboratory Fume HoodsR Laboratory Fume HoodsR UniFlow SE Hoods UniFlow LE Hoods 2018 Made in USA 9001: 2008 Certified 60th Year UniFlow AireStream Laboratory Fume Hoods Fume Hood Service Components Special Purpose Hoods Laboratory

More information

Engineering Information

Engineering Information Finishes WaterSaver standard construction laboratory service fixtures and safety equipment are generally furnished with a chrome plated finish. However, WaterSaver offers a choice of four plated finishes

More information

CORPORATION DURALAB CORPORA

CORPORATION DURALAB CORPORA DURALAB CORPORATION The Tradition Continues the most complete, versatile and colorful line of LABORATORY FUME HOODS and accessories DURALAB CORPORATION 3145 Bordentown Avenue Parlin, NJ 08859 Ph: 888-805-1740

More information

LABORATORY SERVICE FIXTURES

LABORATORY SERVICE FIXTURES Valve Selection Guide Provincial Lab Systems offers a wide selection of valves for use in the laboratory. The selection of a valve for any particular application depends upon many factors, including the

More information

Fume Hoods Overview OVERVIEW

Fume Hoods Overview OVERVIEW OVERVIEW What Is A Fume Hood - A laboratory chemical fume hood is first and foremost a safety device. Users need to be able to rely on their fume hood as a primary containment device to protect them from

More information

User s Manual. Protector Laboratory Fume Hoods

User s Manual. Protector Laboratory Fume Hoods User s Manual Protector Laboratory Fume Hoods XL Floor-Mounted (Walk-In) Models 97008 Series 97009 Series 97010 Series 97160 Series 98604 Series 98605 Series 98606 Series Labconco s Mascot, Labby the LABster

More information

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404) 500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT Table of Contents Introduction...3 500-YVI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor Amperage

More information

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404) 500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT Table of Contents General Information...3 500-YCI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor

More information

82863_Graphx_Conn:Layout 1 11/26/08 8:59 AM Page 1 DUCTLESS ENCLOSURES

82863_Graphx_Conn:Layout 1 11/26/08 8:59 AM Page 1 DUCTLESS ENCLOSURES DUCTLESS ENCLOSURES TABLE of CONTENTS Overview...................................3 Features & Benefits...........................6 Specifications................................7 Ordering Information.........................8

More information

DetectAir KEWAUNEE FILTERED FUME HOODS. encouraging new discovery

DetectAir KEWAUNEE FILTERED FUME HOODS. encouraging new discovery DetectAir FILTERED FUME HOODS KEWAUNEE encouraging new discovery KEWAUNEE DetectAir Filtered Fume Hoods powered by 2 Kewaunee encouraging new discovery DetectAir Filtered Fume Hoods powered by AirClean

More information

Protector XStream Laboratory Fume Hoods

Protector XStream Laboratory Fume Hoods User s Manual Protector XStream Laboratory Fume Hoods Models 9840400, 9840401, 9840402, 9840403, 9840500, 9840501, 9840502, 9840503, 9840600, 9840601, 9840602, 9840603, 9840800, 9840801, 9840802, 9840803

More information

with color-coded index disc. installation on straight face of hood. Valve is installed from behind panel and is secured with external locking ring on

with color-coded index disc. installation on straight face of hood. Valve is installed from behind panel and is secured with external locking ring on Remote Control Fume Hood Fittings Valves L739 Panel Mounted Valve, Angle Face Fume Hood installation on angle face of hood. Valve is installed from behind panel and is secured with external locking ring

More information

.1 Special Building Areas 8. Laboratories..3 Laboratory Casework (section ).4 Chemical storage cabinets (section )

.1 Special Building Areas 8. Laboratories..3 Laboratory Casework (section ).4 Chemical storage cabinets (section ) Part 1 General 1.1 Summary.1 Unless otherwise indicated, follow the standards below when specifying Laboratory Fume Hoods. These standards are not intended to restrict or replace professional judgment..2

More information

User s Manual. Protector XL Floor-Mounted (Walk-In) Laboratory Fume Hoods. Models

User s Manual. Protector XL Floor-Mounted (Walk-In) Laboratory Fume Hoods. Models User s Manual Protector XL Floor-Mounted (Walk-In) Laboratory Fume Hoods Models 97008 Series 97009 Series 97010 Series 97160 Series 98604 Series 98605 Series 98606 Series To receive important product updates,

More information

Open Access Stations Introduction

Open Access Stations Introduction Open Access Stations Introduction Open Access Stations provide personnel, animal and environmental protection while offering utmost efficiency for cage changing operations. Open access on two sides provides

More information

A. Each cabinet must be constructed and installed in accordance with EN12469:2000.

A. Each cabinet must be constructed and installed in accordance with EN12469:2000. BIOLOGICAL SAFETY CABINETS Class II, Biological Safety Cabinet PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this section to the extent referenced. The publications are referred

More information

January, 2014 Page 1 of 6

January, 2014 Page 1 of 6 Part 1 General 1.1 Summary.1 Unless otherwise indicated, follow the standards below when specifying chemical fume hood modifications or installations. These standards are not intended to restrict or replace

More information

LABORATORY FUME HOODS

LABORATORY FUME HOODS Fume Hoods Fume Hood Applications Laboratory professionals and students across the country, and all over the world, depend on the safety of our hoods. Your protection is our first concern and the fume

More information

Square Inline Fans with Multi-Directional Discharge

Square Inline Fans with Multi-Directional Discharge SQN Square Inline Fans with Multi-Directional Discharge Page Introduction............................................2 Standard Construction Features............................ 3 Specifications and Dimension

More information

Direct Gas-Fired Heating

Direct Gas-Fired Heating Direct Gas-Fired Heating Model DG 800 to 15,000 cfm Up to 1,600,000 BTU/hr Optional Evaporative Cooling January 2005 PRODUCT FEATURES Model DG Direct Gas-Fired Make-Up Air Unit The Greenheck model DG is

More information

AUDIO-VISUAL EQUIPMENT

AUDIO-VISUAL EQUIPMENT 11 52 00 AUDIO-VISUAL EQUIPMENT 1. GENERAL A. Related sections: i. 00 00 13 Designing Learning Environments ii. 11 52 13 Projection Screens iii. 12 56 52 Audio-Visual Equipment iv. 72 41 00 General Audio-Visual

More information

Logic+ Technical Manual and Specifications. Type B2 Biosafety Cabinet Models

Logic+ Technical Manual and Specifications. Type B2 Biosafety Cabinet Models Original instructions Logic+ Technical Manual and Specifications Type A1 Biosafety Cabinet Models 30132 30142 30152 30162 Type A2 Biosafety Cabinet Models 30231 30241 30251 30261 30238 30248 30258 30268

More information

User s Manual. Fiberglass 30 Laboratory Fume Hoods. Models Labconco s Mascot, Labby the LABster

User s Manual. Fiberglass 30 Laboratory Fume Hoods. Models Labconco s Mascot, Labby the LABster User s Manual Fiberglass 30 Laboratory Fume Hoods Models 3030000 3030001 3030002 3030003 3030004 3030005 Labconco s Mascot, Labby the LABster The information contained in this manual and the accompanying

More information

User s Manual. XPert Filtered Balance Enclosures & Protector XVS Ventilation Stations. Models

User s Manual. XPert Filtered Balance Enclosures & Protector XVS Ventilation Stations. Models User s Manual XPert Filtered Balance Enclosures & Protector XVS Ventilation Stations Models 2' XPert Balance Enclosures 3930200, 3930201, 3930202, 3930221, 3930222, 3930230, 3930231, 3930232, 3930241,

More information

Annexure-1. Annexure- 1 TECHNICAL SPECIFICATIONS FOR THE MODULAR LABORATORY FURNITURE (CNSNT/RL-4)

Annexure-1. Annexure- 1 TECHNICAL SPECIFICATIONS FOR THE MODULAR LABORATORY FURNITURE (CNSNT/RL-4) Annexure- 1 TECHNICAL SPECIFICATIONS FOR THE MODULAR LABORATORY FURNITURE (CNSNT/RL-4) Item Number-1 ----------------------------------------------------------------------------------------------------------

More information

FVC2100/2200 TEK-AIR TECHNICAL PRODUCT DATA SHEET FUME HOOD FACE VELOCITY MONITOR AND CONTROLLER. Application. General Description

FVC2100/2200 TEK-AIR TECHNICAL PRODUCT DATA SHEET FUME HOOD FACE VELOCITY MONITOR AND CONTROLLER. Application. General Description TEK-AIR TECHNICAL PRODUCT DATA SHEET FVC2100/2200 FUME HOOD FACE VELOCITY MONITOR AND CONTROLLER MODEL 2100: Constant face velocity, variable volume MODEL 2200: Constant face velocity, variable volume

More information

Uncompromised safety. NSF listing provides assurance that you, your work and your laboratory environment are protected while working with agents that

Uncompromised safety. NSF listing provides assurance that you, your work and your laboratory environment are protected while working with agents that Uncompromised safety. NSF listing provides assurance that you, your work and your laboratory environment are protected while working with agents that require Biosafety Level 1, 2 or 3 containment. Stainless

More information

When Time Matters! listed Fire Damper

When Time Matters! listed Fire Damper listed Fire Damper The FAST fire damper is offered as an option for containing fire and smoke under the hood in the event of a fire from a cooking appliance. Construction : The fire damper is assembled

More information

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES FAN TERMINAL UNIT SPECIFIABLE FEATURES Galvanized steel casing, mechanically sealed for low leakage construction NEMA TYPE 1 rated hinged control enclosure with standoff to prevent penetration of casing

More information

Fume hood construction details. VANGUARD FUME HOODS Listed by Intertek to UL 1805 standard page 1. Features

Fume hood construction details. VANGUARD FUME HOODS Listed by Intertek to UL 1805 standard page 1. Features Fume hood construction details 1 9 2 10 3 11 13 4 14 5 15 6 16 17 7 12 18 8 Features 1 Fluescent light fixture with interi sealed glass offering a safe and bright wking area (100 foot candles) 2 SEFA-8

More information

new fume hoods providing performance and protection

new fume hoods providing performance and protection new fume hoods providing performance and protection five questions to get us started 1. Will the use of your hood require a special application hood? 2. How high of a priority is energy conservation? 3.

More information

Fume hood construction details VANGUARD FUME HOODS. Listed by Intertek to UL 1805 standard. page 1. Features

Fume hood construction details VANGUARD FUME HOODS. Listed by Intertek to UL 1805 standard. page 1. Features Fume hood construction details 1 2 3 4 5 6 7 9 10 11 13 14 15 16 17 12 18 8 Features 1 Fluescent light fixture with interi sealed glass offering a safe and bright wking area (100 foot candles) 2 SEFA-8

More information

HOOD ACCESSORIES HOOD ACCESSORIES HOOD ACCESSORIES

HOOD ACCESSORIES HOOD ACCESSORIES HOOD ACCESSORIES HOOD ACCESSORIES 58 59 VAPORPROOF RECESSED INCANDESCENT LIGHT FIXTURE VAPORPROOF LIGHT FIXTURES RECESSED INCANDESCENT LIGHT FIXTURE Specifications Cut-Out Mounting Diagram Socket: Side mounted porcelain

More information

Model ND-2 Specification

Model ND-2 Specification Model ND-2 Specification The model ND-2 is an exhaust only canopy hood rated for all types of cooking equipment. The hood shall have the size, shape and performance specified on drawings. Construction

More information

Series 301. Horizontal Laminar Flow Clean Bench. C l e a n B e n c h e s. s o l u t i o n s. Series 301 Horizontal Laminar Flow Clean Bench

Series 301. Horizontal Laminar Flow Clean Bench. C l e a n B e n c h e s. s o l u t i o n s. Series 301 Horizontal Laminar Flow Clean Bench Series 301 Horizontal Laminar Flow Clean Bench s o l u t i o n s The Series 301 is a general-purpose, horizontal flow clean bench ideally suited to many types of mechanical or processing work. It is designed

More information

EGG CRATE RETURN GRILLE

EGG CRATE RETURN GRILLE 80 EGG CRATE RETURN GRILLE 80 The 80 Series is available in various mounting styles and features sturdy construction, consisting of a heavy gauge aluminum grid core, optional extruded aluminum borders

More information

Mobility Optima Mobile Workstation

Mobility Optima Mobile Workstation Optima Mobile Workstation Mobile, adjustable and self contained workstations designed to enhance lab productivity. With a push of a button the work surface adjusts to meet the height demands of individual

More information

Series 577. Vertical Flow Softwall Portable Cleanroom. Series 577 Vertical Flow Softwall Portable Cleanroom

Series 577. Vertical Flow Softwall Portable Cleanroom. Series 577 Vertical Flow Softwall Portable Cleanroom Series 577 Vertical Flow Softwall Portable Cleanroom s o l u t i o n s The Series 577 softwall portable clean rooms are a cost-effective method of providing quality particulate control enclosures. The

More information

Thirteen (13) UL listed fluorescent fixtures per booth will supply illumination.

Thirteen (13) UL listed fluorescent fixtures per booth will supply illumination. Quoted as per your request: two (2) Non-Pressurized, Drive-Thru, Full Down Draft, Paint Booth model: TDD-16-16-20-DT with interior working dimensions of 16-0 wide X 16-0 tall X 20-0 long. Overall dimensions

More information

Ventilated Balance Enclosures

Ventilated Balance Enclosures Ventilated Balance Enclosures by PLAS n LABS Meets and exceeds ANSI/ASHRAE 110:2016 standard for containment & performance PLAS n LABS, INC. www.plas-labs.com PLI@PLAS-LABS.com 517-372-7177 Ventilated

More information

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410. PART 1 - GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

SOLAR HEATING SYSTEM

SOLAR HEATING SYSTEM SECTION 13600 SOLAR HEATING SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 07600 - Flashing and Sheet Metal. 2. 07900 - Joint Sealers. 3. 15260 - Thermal Insulation (Plumbing). 4. 15410 - Piping

More information

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Copyright 2008 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA SECTION 11 53 00 - LABORATORY EQUIPMENT PART

More information

Design Requirements The system shall be designed, manufactured, tested and installed in compliance with the current versions or issuance of:

Design Requirements The system shall be designed, manufactured, tested and installed in compliance with the current versions or issuance of: SECTION 15877 FUME HOODS 1. General 1.1. Summary These specifications provide a performance specification for a chemical laboratory Fume Hood (herein referred to as FH). The intent of the specification

More information

DESIGN STANDARDS WASHINGTON UNIVERSITY SCHOOL OF MEDICINE

DESIGN STANDARDS WASHINGTON UNIVERSITY SCHOOL OF MEDICINE SECTION 11 53 00 (11610) - LABORATORY FUME HOODS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1

More information

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct Tubular Centrifugal Inline Fans Page Introduction........................................... 2 Construction Features.................................. 3 Specification and Dimension Data TCN-D (Inline Fan-

More information

WAC Air Curtains Technical Guide

WAC Air Curtains Technical Guide TGWAC-2 WAC Air Curtains Technical Guide FOR WIND STOPPING, INSECT CONTROL, AND ENVIRONMENTAL SEPARATION IN COMMERCIAL AND INDUSTRIAL APPLICATIONS TABLE OF CONTENTS Introduction......................................................................2

More information

Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges

Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges Phone: 800-348-1097 www.aeipaintbooths.com Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges Thank you for the opportunity to work with you on your paint booth project. Below

More information

Lighthouse Power Pedestals,

Lighthouse Power Pedestals, Lighthouse Power Pedestal One of our most popular units, the all-purpose Lighthouse pedestal has a wide range of features. With units in service around the world, this stylish power pedestal is recognized

More information

GE Monogram. Installation. Instructions. Professional Vent Hoods. 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS. 36" Models ZV671WSS, ZV681YSS

GE Monogram. Installation. Instructions. Professional Vent Hoods. 48 Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS. 36 Models ZV671WSS, ZV681YSS GE Monogram Installation Instructions Professional Vent Hoods 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS 36" Models ZV671WSS, ZV681YSS ZV670WSS, ZV680YSS 30" Models ZV370YSS, ZV371YSS CAUTION WARNING

More information

Quotations are invited for Fume Hoods for Chemistry Laboratory Pre Qualification Criteria

Quotations are invited for Fume Hoods for Chemistry Laboratory Pre Qualification Criteria Quotations are invited for Fume Hoods for Chemistry Laboratory Pre Qualification Criteria 1) The laboratory fume hoods must confirm to the following regulations and standards. 2) ASHRAE 110 1995, American

More information