Installation Instructions
|
|
- Brittany Cain
- 5 years ago
- Views:
Transcription
1 HN-300 Fixture Mount Nightlight Controller with LED Assembly SPECIFICATIONS Power VAC, 60Hz Relay Type... Form A, N.O. Load 500W isolated relay rated 5A 250VAC Low Voltage Connections RJ45 connection to FS sensor... Control in, common, +24VDC 8-Pin connector to LED strip and battery 2-wire output to LEDs.... max. 2-wire output to 9V Ni-MH battery max. Line and Load Connections AWG terminals Operating Temperature to 131 F (0 to 55 C) HN-200 Dimensions x 0.75 x 1.5 (190 x 19 x 38mm) LED Light bar Dimensions long x 0.5 dia. (30.8cm x 12.7mm) Installation Instructions
2 04799r1 C US LISTED Appliance Control 88T9 Model: Santa Clara, CA r1 DESCRIPTION The HN-300 kit contains an HN-200 controller plus a complete LED nightlight assembly. This assembly includes a 9V Ni-MH rechargeable battery, plug-in low voltage connector, LED light bar and a set of translucent mounting brackets that can be positioned anywhere along the light bar to facilitate mounting on the fixture. In addition, the mounting brackets are hinged for easy angle adjustment. The HN-200 controller supplies power to FS series occupancy sensors, a light fixture ballast and the LED light bar. It also supplies a trickle charge for a 9Volt battery that provides backup power to the LED light bar. The HN-200 is designed for installation inside the lighting fixture housing. The HN-200 has a male RJ45 plug attached to a 10 cable. Each FS series 24VDC occupancy sensor is equipped with a cable that carries power to the sensor and lighting control signals to the HN 200. The two devices connect using the shielded male-to-male RJ45 coupler provided with the HN-200. Typically, the HN-200 connects to one FS sensor inside the lighting fixture, however, each HN-200 can power up to three FS series sensors. FS-Cx accessories are required to connect multiple sensor wiring configurations. OPERATION The HN-200 must be used with a Legrand momentary switch, provided with the HN-200. The switch toggles the fixture between full lighting operation, nightlighting using the LEDs, and no lighting at all. When the light fixture is ON, the FS sensor controls the light. When no motion is detected and the occupancy sensor s delay expires, the light goes OFF and the LED nightlight goes ON. Push the switch button twice to force OFF all lights. During a power failure lasting more than 2 seconds, the HN-200 uses the 9V battery to power the LEDs. To conserve battery, the LEDs appear dimmer than during normal nightlight operation. The length of time the LEDs are lit during a power failure depends on battery status. To protect the battery, the HN-200 turns off the LEDs when the battery discharges below a safe level. Low voltage connector to LED night light and Battery wire assembly Shielded male-to-male RJ45 extension connector Low voltage RJ45 connection to FS sensor Line voltage input and Switch wiring 120VAC Input HOT NEUTRAL GROUND Strip Gauge 12-18AWG CU wire only HN-200 Fixture Nightlight Controller 120VAC, 5A (N/O) ISOLATED RELAY OUTPUTS TO COM Green LED Fig 1: HN-200 connections and operation monitor LED Call or for Technical Support
3 04800r1 INSTALLATION 1. Determine an appropriate mounting location for the HN-200 inside the light fixture. Use the holes or mounting slots at both ends of the HN-200 to secure it to the fixture. 2. Determine a suitable mounting location on the outside of the fixture for the LED light bar. Make sure the 8-pin connectors from the LED light bar and the HN-200 meet. Make a 3/4 opening in the enclosure. Run the wire assembly from the LED light bar into the fixture by inserting it s 8-pin connector through a 3/4 opening. Install a grommet to protect the wires. 3. Install the LED light bar on the fixture using the mounting brackets (Fig 3). 4. Connect the 8-pin low voltage connector from the HN-200 to the 8-pin connector for the battery and LED light bar wire assembly. 5. Connect the 9V rechargeable Ni-MH battery to the snap-on terminals on the battery wire assembly inside the fixture. 6. Install the FS sensor and make appropriate adjustments as described in the FS installation instructions. 7. Connect the RJ45 from the sensor to the RJ45 on the HN Connect wires to load, switch and electrical supply as shown in the wiring section. High voltage wiring should use at least 16 AWG wire. Check local building codes. WIRING CAUTION MAKE SURE POWER IS OFF BEFORE WIRING THE SWITCH OR CONTROLLER AWG Line (Black) 1 L 2 Legrand Momentary N/C Switch Cu Only HOT to COM Neutral (White) Ground (Green) 120VAC Input HOT NEUTRAL GROUND 04799r1 Strip Gauge 12-18AWG CU wire only C US LISTED Appliance Control 88T9 Model: HN-200 Fixture Nightlight Controller 120VAC, 5A (N/O) Santa Clara, CA ISOLATED RELAY OUTPUTS TO COM Neutral (White) Fig 2: HN-200 electrical supply, switch and load wiring Visit our website for FAQs:
4 120VAC Input HOT NEUTRAL GROUND 04799r1 C US LISTED Appliance Control 88T9 Fixture Nightlight Controller 120VAC, 5A (N/O) Santa Clara, CA COM 04800r1 Knockout with Rubber Grommet Wire Assembly Adjustable Mounting Brackets LED Light Bar 9VDC Rechargeable Battery Strip Gauge 12-18AWG CU wire only Model: HN-200 ISOLATED RELAY OUTPUTS TO Red Black 8-Pin Connector BALLAST Male-to-Male RJ45 Connector FS-205-HN Sensor Exterior of Fixture Enclosure Interior of Fixture Enclosure Fig 3: HN-300 LED nightlight assembly and mounting Adjustable Mounting Brackets LED Night Light Bar Bulbs HN-200 Interior of Fixture Enclosure WALL Diffuser or Shade Sensor Call or for Technical Support
5 TROUBLESHOOTING Lights will not turn on: Sensor LED does not flash: - Is green HN-200 LED on? If yes, check RJ45 connections between sensor and HN-200. If no, check circuit breaker and wiring to wall switch and HN Check all wire connections. LED does flash: - Press the wall switch to toggle between OFF, nightlight, and full operation. - Check all wire connections and verify the load wire is tightly secured. Is the switch wired correctly? If the sensor has a light level feature, set it to maximum (even the brightest ambient light will not hold off the light fixture) and then retest to see if the lights turn on. If lights still do not turn on, call for technical support. Lights will not turn off: The time delay on the FS sensor can be set from 30 seconds to 30 minutes (60 minutes for the FS-205-HN). Ensure that the time delay is set to the desired delay and that there is no movement within the sensor s view for that time period. To quickly test the unit for proper operation, turn the time delay to minimum and move out of the sensor s view. Lights should turn off after 30 seconds. If lights still do not turn off, call for technical support. LED nightlight will not turn on: Cycle the wall switch by pushing the button to change between the main fixture light source and the LED nightlight. Check connections between LED light bar and HN-200 controller. Call or for Technical Support
6 ORDERING INFORMATION Catalog # HN-300 FS-105 FS-205 Description Fixture nightlight package includes: one HN-200 controller (120VAC, 60Hz), one male-to-male RJ45 connector, one Legrand wall switch and cover plate, one LED light bar, one low voltage LED and battery wire assembly, one 9VDC rechargeable battery (sensor sold separately) Ceiling tile mount, low voltage PIR occupancy sensor with adjustable time delay and light level, 6 cable Fixture mount, low voltage PIR occupancy sensor with adjustable time delay and light level, 6 cable FS-205-HN Fixture mount, low voltage PIR occupancy sensor with adjustable time delay (up to 60 minutes) and light level, 1 cable. FS-305 FS-405 FS-505 FS-505C Fixture or ceiling tile mount, low voltage PIR occupancy sensor, adjustable time delay, 6 cable Fixture mount, low voltage PIR occupancy sensor w/20 diameter coverage, adjustable time delay and light level, 6 cable Fixture mount, low voltage ultrasonic occupancy sensor, 2 cable Same as FS-505, with directional cones All sensors and HN-200 are White. WARRANTY INFORMATION Watt Stopper/Legrand warranties its products to be free of defects in materials and workmanship for a period of five (5) years. There are no obligations or liabilities on the part of Watt Stopper/Legrand for consequential damages arising out of, or in connection with, the use or performance of this product or other indirect damages with respect to loss of property, revenue or profit, or cost of removal, installation or reinstallation De La Cruz Boulevard, Santa Clara, CA Technical Support: r1 03/2006
Installation Instructions
SPECIFICATIONS v2 Fixture Mount Power Pack Model: Fixture Sensor Power Pack V2 120/277/347VAC, 60Hz @347VAC 3.4A () 2A () Power...120/277/347VAC, 60Hz Relay Type... Form C with Zero Crossing on N.O. only
More informationInstallation Instructions
BZ-200, BZ-250, BZ-250-347 Power Pack Auto/Manual Mode Switch BZ-250, BZ-250-347 only SPECIFICATIONS Voltages BZ-200, BZ-250... 120 277 VAC, 50/60 Hz, single phase BZ-250-347... 120 347 VAC, 50/60 Hz,
More informationInstallation Instructions
DT-300 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On features Specifications Voltage...18-28VDC/VAC, half wave rectified AC Current Consumption...43mA
More informationBZ-150. Installation Instructions. Power Pack SPECIFICATIONS
SPECIFICATIS Voltages...120/. 50/60Hz Load Requirements Ballast... 20amp @120/ Incandescent... 20amp @ Motor... 1HP @120/240VAC Output...225mA @ (with relay connected) Input Control... 12- Hold... 12-
More informationInstallation Instructions
Bi-Level Control Module For fixtures with CWA transformers and non-encased capacitors, using Metal Halide, Metal Halide (Pulse Start) or High Pressure Sodium lamps between 75-000W Model#s: -250H -400H
More informationInstallation Instructions
Please read all instructions before installing CD-250 Multi-way Dimming Wall Switch Vacancy Sensor Lens Air Gap Isolation Switch Lighted Switch ON/OFF/DIM button SPECIFICATIONS Voltage...120VAC, 60Hz Load
More informationInstallation Instructions
ADFE-A Three-Wire Fluorescent Multi-way Architectural Dimmer SPECIFICATIONS Dimming slider On/Off switch Label slot Voltage...2VAC, Hz Maximum Load Rating... A Minimum Load Rating....33A Narrow Dimmer:
More informationInstallation Instructions
ADFM277-A Two-Wire Fluorescent Multi-way Architectural Dimmer Dimming slider On/Off switch Label slot SPECIFICATIONS Voltage...277VAC, Hz Maximum Load Rating... A Minimum Load Rating....33A Wide Dimmer:
More informationAura Interior Wiring Manual (5-Wire and BACnet)
(5-Wire and BACnet) Table Of Contents Preparation......2 Warranty.....2 Aura Interior Product Overview....3 Aura Interior Power Wiring......4 Aura Interior RS485 Wiring...5 Aura Interior Remote Motion
More informationUSER MANUAL 12 OUTLET 120/240V X-PLUG LIGHT CONTROLLER (FUEL SX12) APTX0120
USER MANUAL 12 OUTLET 120/240V X-PLUG LIGHT CONTROLLER (FUEL SX12) APTX0120 OVERVIEW The Autopilot Fuel SX12 Twelve Light X-Plug 120/240V Light Controller (APTX0120) represents the latest in large scale
More informationInstallation and Operation Instructions 10/04/13
ELI-S-100 With DIMMING CAPABILITIES Installation and Operation Instructions eli series emergency lighting inverters NRTL/C! IMPORTANT SAFEGUARDS! WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS
More informationMotion Sensing Coach Light
TM Motion Sensing Coach Light Model: SH-9291AU Installation and Operating Instructions FEATURES Automatically comes on when motion is detected. Automatically turns light off. Photocell keeps the light
More informationRK Standby Battery Operator s Manual
49-8104RK Standby Battery Operator s Manual Part Number: 71-0118RK Revision: C Released: 8/4/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by us to
More informationRK Standby Battery Operator s Manual
49-8103RK Standby Battery Operator s Manual Part Number: 71-0117RK Revision: 0 Released: 8/18/08 www.rkiinstruments.com Product Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to
More informationACC Series Power Conditioner OPERATION & INSTALLATION MANUAL
ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL PHASETEC digital power conditioners are designed to safely operate electrical equipment in the harshest power quality environments. With a wide
More informationLED Garage Light INSTALLATION INSTRUCTIONS. *Model number noted on carton label
LED Garage Light *Model number noted on carton label INSTALLATION INSTRUCTIONS Model Number / Número de Modelo / Numéro des modèle SGLL 24 PIR (24 LED Garage Light) Actual Dimensions 10 W x 3-1/2 H x 24-1/2
More informationSAFE & SECURE ACTUATOR PRODUCT MANUAL
INDELAC CONTROLS SAFE & SECURE ACTUATOR PRODUCT MANUAL Product Description: The Safe & Secure Series Actuator is a quarter turn Open/Close Actuator with Battery Backup Power ALL IN ONE! No more mounting
More informationThe Ultimate Smart Grid Solution INSTRUCTION MANUAL
ECOWISE EW30/1 The Ultimate Smart Grid Solution INSTRUCTION MANUAL Welcome! Congratulations on selecting the ECOWISE unit to manage your energy supply needs. ECOWISE units reduce the amount of electric
More informationmodel ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION
MODEL: PS600 HZ: 60 A model ps600 installation and service manual for federal model ps600 FEDERAL SIGNAL CORPORATION POWER SUPPLY VOLTS: SERIES: 120VAC FEDERAL SIGNAL CORPORATION UNIVERSITY PARK, IL. U.S.A.
More informationACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS
II 1400-8 Features: ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS Filtered/Regulated 24 Volts DC Up to Full 2 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit
More informationZoneZ Lite Quick Start Guide
Table Of Contents Preparation......2 ZoneZ Lite Overview....3 ZoneZ Lite Contact Closure Wiring......4 ZoneZ Lite Contact Closure Three-Way Wiring....5 ZoneZ Lite Contact Closure All On/Off Wiring.....6
More informationTransfer Switch GPTS 30
Transfer Switch GPTS 30 Owner s Manual Table of Contents Introduction 2 Installation 3 Operational Testing 7 Troubleshooting 8 Hi-Pot Testing 9 Generator Note 10 Medical Appliances 10 Caution 10 Warranty
More informationPD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number
0-10V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V 4 circuit Analog 1-10V 4 x 4 A. Dimmer pack Serial Number Dimmers Indicators Digital Lighting Systems,Inc Info@digitallighting.com
More informationTC26-B Vehicle Sensor
Section 1 General Description The Model TC26-B is a microprocessor controlled vehicle sensor with a variable range. It is designed to trigger the operation of a traffic controller. The TC26-B will only
More informationUser Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736
User Manual T6 Tachometer Online: www.phareselectronics.com Telephone: 727-623-0894 P.O. Box 67251 St. Petersburg, Florida 33736 Table of Contents Overview... 1 Description... 1 Wiring... 1 T6 Tachometer
More informationThe Ultimate Smart Grid Solution INSTRUCTION MANUAL
ECOWISE EW20/1 EW30/1 The Ultimate Smart Grid Solution INSTRUCTION MANUAL Welcome! Congratulations on selecting the ECOWISE unit to manage your energy supply needs. ECOWISE units reduce the amount of electric
More informationCompact 150 Watt Motion Sensing Halogen
TM Compact 150 Watt Motion Sensing Halogen Model: SH-9511AU Installation and Operating Instructions FEATURES Automatically comes on when motion is detected. Automatically turns light off. Photocell keeps
More informationDUALBRITE Motion Sensing Coach Light
DUALBRITE Motion Sensing Coach Items Models 007677 SH-4144-AZ-B 063285 SH-4152-BK-A Questions or problems? Before returning to your retailer, refer to the troubleshooting guide in this manual or call our
More informationMaxLite LED Medium Area Light
General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions
More informationDIN Rail UPS Model: DIN-UPS Installation/Operation Manual
DIN Rail UPS Model: DIN-UPS 24-10 Installation/Operation Manual Table of Contents Section Page Section Page Quick Start 2 1) General Information 4 Materials Provided 4 Optional Equipment 4 2) Safety Information
More informationAUTO CHARGE 1200 PUMP PLUS
FILE: 091-193-12.pmd REV: B REVISED BY: MFG DATE: 2-14-2011 INSTRUCTION MANUAL AUTO CHARGE 1200 PUMP PLUS AUTOMATIC BATTERY CHARGER MODEL #091-9-1200 INPUT: 115 volt, 50/60 Hz, 10 amps OUTPUT: 40 AMPERES
More informationBRAVO Inverter/Battery Charger. Table of Contents
BRAVO 1050 Inverter/Battery Charger Table of Contents Introduction... 2 General Description... 2 Specifications... 3 Installation: Hardwire Units... 4 Operation: Hardwire Units... 5-6 Installation: GFCI
More informationAUTO CHARGE LPC SERIES
INSTRUCTION MANUAL FILE: IM_091-206-12_revB REV: B REVISED BY: THN DATE: 09-17-2012 AUTO CHARGE LPC SERIES MODEL #091-206-12 LPC STANDARD DISPLAY INPUT: 115 volt, 50/60 Hz, 13 amps OUTPUT: 80 AMPERES 3
More informationUser Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring
User Manual JS-ICON 624 ARCH Dimmer Rack JOHNSON SYSTEMS INC. Spring 2007 2002161 Table of Contents JS-ICON 624 DMX JS-ICON 624 CC 6-2.4kW Dimming Strip JS-ICON 624 ND 6-2.4kW Relay Strip Introduction...3
More informationLN3 Series Motor and Drives
LN3 Series Motor and Drives Operator's Manual PN 04-01906 C PRECISION MOTION CONTROLS 2175 De La Cruz Blvd. #1 Santa Clara, CA 95050 LN3 Manual CONTENTS Introduction... 3 Description... 3 Features... 3
More informationDIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual
DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS 24-10 Installation/Operation Manual Table of Contents Section Page Section Page Quick Start 2 1) General Information 4 Materials Provided
More informationOperations Manual. Zero Speed Switch Sensor Model ZS09P
Zero Speed Switch Sensor Model ZS09P The must be referred to for correct installation. Failure to comply with the shall void all warranties and liabilities. Overview The Phares Electronics Model ZS09P
More informationPMWS2W SURFACE MOUNT 2-WIRE WALL SWITCH
infirm and children at night or when it is dark. Note: Read this entire manual before you start to install the system. SAFETY PRECAUTIONS PMWSW SURFACE MOUNT -WIRE WALL SWITCH Be sure to switch off power
More informationCarbon Monoxide Transmitter
Introduction The CO Transmitter uses an electrochemical sensor to monitor the CO level and outputs a 4-20 ma signal. The standard product features a 2- wire loop-powered output. Optionally, the device
More informationAFM500X Automatic Flashing Module
AFM500X Automatic Flashing Module The Power-Tronics AFM500X Automatic Flashing Module is a convenient and compact optional build up module for all Power-Tronics UVR and XR series Universal Voltage Regulators.
More information0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)
Mechatronic Analog Timer H3AM Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and
More informationModel NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006
B R A N D Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006 For Sales, Support and Service phone: 407-331-4793 fax: 407-331-4708 website: www.xenotronix.com email: information@xenotronix.com
More informationOutdoorXUPS-600AHV-8364
OutdoorXUPS-600AHV-8364 TSi Power s OutdoorXUPS-600AHV-8364 provides secure and uninterrupted 230 vac power to critical loads. 1) Weather-tight metal cabinet (IP44 or NEMA 3R rated) 2) 2A and 2B are wide
More informationLED Auxiliary Devices
LED Auxiliary Devices 30 YEARS OF EXCELLENCE 1985-2015 Incorporated in the state of California in 1985, McWong International, Inc. has grown to become a strategic supplier of high-quality lighting control
More informationWF-5110R True Sine Wave Inverter
Operator s Manual WF-5110R True Sine Wave Inverter WF-9900 Series WF-5110R ( The Inverter model number is located on the label on top of the enclosure) Distributed in the U.S.A. and Canada by ARTERRA DISTRIBUTION
More information007 Tank Monitor. WARNING Never use with gasoline or highly flammable liquids.
Model #7575 Recommended Installation, Maintenance and Inspection Instructions 007 Tank Monitor 7575 Important safety instructions - save these instructions in a readily accessible location. WARNING Never
More informationLED Downlight Ceiling Fixtures
ED Downlight Ceiling Fixtures Every attempt has been made to ensure that this documentation is as accurate and up-to-date as possible. However, Vertical Express assumes no liability for consequences, directly
More informationPlug-in Dimmer Socket Kit
Plug-in Dimmer Socket Kit Model No. JSJSLW301 Instruction Manual Connect Series www.lightwaverf.house Version 2 EC DECLARATION OF CONFORMITY Responsible Authority: LightwaveRF PLC, Innovation Campus Birmingham
More informationLED Emergency Drivers
LED Emergency Drivers Incorporated in the state of California in 1985, McWong International, Inc. has grown to become a strategic supplier of high-quality lighting control equipment and related electrical
More informationIMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS
THIS UNIT CONTAINS A RECHARGEABLE VALVE-REGULATED LEAD ACID BATTERY. PLEASE RECYCLE OR DISPOSE OF PROPERLY. IMPORTANT SAFEGUARDS INTERRUPTIBLE EMERGENCY LIGHTING UNIT INVERTER INSTRUCTION MANUAL When using
More informationOWNER S MANUAL AND INSTALLATION INSTRUCTIONS
EmerGen Switch Manual Transfer Switch OWNER S MANUAL AND INSTALLATION INSTRUCTIONS For A Series Models 6-5001, 6-7501, 10-7501, 10-12K1 PLEASE READ THIS MANUAL IN ITS ENTIRETY BEFORE INSTALLING AND/OR
More informationTransient Fault Location for Branch Circuit Breakers TFT Turquoise Circle Newbury Park, CA Toll Free:
TFT100 2450 Turquoise Circle Newbury Park, CA 91320 Toll Free: 800-749-5783 User Manual Introduction Fault Trapper is a new class of tester intended to locate the distance to a circuit anomaly that is
More informationINSTRUCTION MANUAL MODEL # YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.
FILE: 091-84.pmd DATE: 9-21-07 INSTRUCTION MANUAL AUTO THROTTLE 1 MODEL #091-84 AN AUTOMATIC HIGH IDLE CONTROLLER 3 YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC. 170 CHERRY AVE., WEST SAYVILLE, N.Y. 11796
More informationLumencia. LLMPS SERIES Micro Power Systems. Multi-Unit Residential Lighting. Job Name: Type:
APPLICATIONS LLMPS Series inverter systems are designed to provide sinusoidal AC emergency power to incandescent, flourescent, or LED fixtures of between 20 and 55 watts. Surface, recessed or ceiling T-Grid
More informationAquiTron. AT-PIR-SOV Water Shut-Off System INSTALLATION INSTRUCTIONS
AquiTron Water Shut-Off System INSTALLATION INSTRUCTIONS System Please read these instructions carefully and keep them in a safe place (preferably close to the module) for future reference. These instructions
More information2904 Power Supply Installation Instructions I-EA00041
FEATURES Controls an opening with electrified locking device and automatic door operator Separate inputs for activation switch on entry and exit sides of opening Separate 24 VDC outputs for fail safe and
More information3200 SERIES BACK LIT CONVEYOR Special Capabilities Specification Sheet
975 Cottonwood Ave., PO Box 20, Hartland, Wisconsin 53029-0020, USA www.dorner.com info@dorner.com BACK LIT CONVEYORS A light fixture is installed inside the conveyor frame and emits light through a translucent
More informationPROFESSIONAL 270 o PIR MOTION DETECTOR
PROFESSIONAL 270 o PIR MOTION DETECTOR The unit can be installed only vertically (see the FIGURE 1A), not upside-down or horizontally (see the FIGURE 1B) as shown in the below drawing. FIGURE 1A 1. Motion
More informationApplication Engineering
Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor
More informationU00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004
U00X ULTRASONIC LEVEL SWITCH INSTALLATION AND OPERATIONS MANUAL Ultrasonic Liquid Level Switches For Non-Hazardous Locations For Models: U002, U003 & U004 READ THIS MANUAL PRIOR TO INSTALLATION This manual
More informationTekleen GB6 & GB7 USERS AUTOMATIC FILTERS, INC. MANUAL
AUTOMATIC FILTERS, INC. 67 S. LA CIENEGA BLVD. LOS ANGELES, CA 90034 30 839 88 800 336 94 FAX 30 839 6878 www.tekleen.com info@tekleen.com Tekleen GB6 & GB7 USERS MANUAL GB6 & GB7 USERS MANUAL AUTOMATIC
More informationContacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Low energy contacts gold plated. Minimum PUSHBUTTON
Pilot Devices Technical data UL General UL technical data Contact blocks Rated insulation voltage, UL 600V Rated thermal current 10A / 600VAC 2.5A / 600VDC Minimum rating 24VDC, 5mA Mechanical life (millions
More informationINDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 KUSSMAUL ELECTRONICS CO., INC. MODEL # XX YEAR WARRANTY INSTRUCTION MANUAL
INSTRUCTION MANUAL FILE: 091-106-150-XX-120 DATE: 10-2-2009 REV: A INDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 MODEL # 091-106-150-XX-120 3 YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC. 170
More informationASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY
00 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) Track Assembly (0-) / Replacement
More informationFM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017
FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017 Maxi-Tronic, Inc. 417 Wards Corner Road Loveland, OH 45140 513.398.2500 800.659.8250 FAX: 513.398.2536 info@maxitronic.com
More informationProduct Installation Document
Honeywell 12 Clintonville Road Northford, CT 064721610 http://www.honeywellpower.com HP1205UL4, HP1205UL8, HP12010UL8, HP1210UL16 Power Supplies/Distribution Units PN 0618131: A 07/18/13 Product Installation
More informationSAVE THESE INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFEGUARDS! When using electrical equipment, basic safety precautions should always be followed
More informationSAVE THESE INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFETY INSTRUCTIS! WARNING To reduce the risk of death, injury or property damage from fire,
More informationTransfer Switch TS-50. Owner s Manual
Transfer Switch TS-50 Owner s Manual Table of Contents Introduction 2 Installation 2 Operational Testing 7 Troubleshooting 7 Hi-Pot Testing 8 Generator Note 9 Medical Appliances 10 Caution 10 Disclaimer
More informationVigilante Series. Wallpack. We light your world
Vigilante Series Wallpack We light your world 1.8.18 Vigilante Series LED 15w/2w/24w/3w/42w/ 6w/8w/1w/w IP65 - IK8 PRODUCT OVERVIEW The Vigilante Series led wall luminaire is a stylish, fully integrated
More informationDimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company
Manufacturer of Dimensions Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com OWNERS MANUAL April
More informationASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY
0 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) / Replacement Motor Key (00KEY) Rod
More information8-Unit Case Package Contents
8-Unit Case Package Contents LA-321/324 Contents LA-321 8-Unit Charging/Carrying Case or LA-324 8-Unit Charging/ Carrying Case Power Supply Keys Shoulder Carrying Strap LA-322 Contents LA-322 8-Unit Storage/Carrying
More informationHDE36 BATTERY POWERED CRIMP TOOL
Description The HDE36 Battery Powered Crimp Tool is a hand held, self contained crimp tool intended to crimp copper and aluminum cable with DMC HD36 dies. Important Safety Information Safety Safety is
More informationIndustry Compliance The cabinet and modules are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.
Power Switching Introduction CRESTRON GREEN LIGHT power switching cabinets come pre-configured with GLXP modules already installed. The cabinets only require installation and wiring of feed and load circuits.
More informationValveMate 7000 Controller Operating Manual
A NORDSON COMPANY ValveMate 7000 Controller Operating Manual Steady Test Clear Time Set Fast Slow POWER RUN SETUP CYCLE A NORDSON COMPANY VALVEMATE 7000 Run Setup Purge Program Fast Slow Time Set Pressure
More informationWF-5110R True Sine Wave Inverter
Operator s Manual WF-5110R True Sine Wave Inverter WF-9900 Series WF-5110R ( The Inverter model number is located on the label on top of the enclosure) Distributed in the U.S.A. and Canada by ARTERRA DISTRIBUTION
More informationITS-50R TRANSFER SWITCH OWNER S MANUAL
ITS-50R OWNER S MANUAL IOTA Engineering Transfer Switches provide automatic power switching between two or three separate 120/240 volt AC input sources, including powercords, onboard generators, onboard
More informationASSEMBLY AND INSTALLATION INSTRUCTIONS
ASSEMBLY AND INSTALLATION INSTRUCTIONS 348-0035 / 348-0036 WARNING: TO AVOID RISK OF ELECTRICAL SHOCK, BE SURE TO SHUT OFF POWER BEFORE INSTALLING OR SERVICING THIS FIXTURE. NOTES: 1. Before installing,
More informationInstallation Instructions for Eaton Surge Protective
Contents Description Page PH Model Introduction.... 2 Safety Precautions.... 2 Operation.... 2 Preparation... 2 Installation Procedures... 3 Enclosure Mounting (New Applications - Eaton PH and PV Models)....
More informationNEW PRODUCTS MAY 1, NEW PRODUCTS. MEP-81000WL POWER CENTER PAGE 3 To watch the video go to
MEP-81000WL POWER CENTER PAGE 3 To watch the video go to www.maxxima.com/mep-81000wl MAY 1, 2018 25 PANOR CORP/MAXXIMA 125 Cabot Court, Hauppauge, NY 11788 USA Tel: 631.434.1200 1.866.MAXXIMA Fax: 631.952.0349
More informationSure-Lites LPXC SERIES. Input Voltage Input Power 19 3/4" " /8" /8" 54 13" /2" 191
DESCRIPTION The LPX combo series is a UL 924 code compliant solution for exit and emergency requirements and is designed to operate for a minimum of 90 minutes during a outage. Features include a polycarbonate
More informationIMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS
THIS UNIT CONTAINS A RECHARGEABLE VALVE-REGULATED LEAD ACID BATTERY. PLEASE RECYCLE OR DISPOSE OF PROPERLY. IMPORTANT SAFEGUARDS INTERRUPTIBLE EMERGENCY LIGHTING UNIT INVERTER INSTRUCTION MANUAL When using
More informationAura CM-54i Surface Mount Illuminated Enclosure
Door Activation Devices Aura CM-54i Surface Mount Illuminated Enclosure Package Contents 1 CM 54i 1 Blue/Green/Red Aura PCB 2 # 6 X 3/8 Screws 1. GENERAL DESCRIPTION Camden Aura, Model CM-54i provide the
More informationDIN Rail UPS Model: DIN-UPS 48-5 Installation/Operation Manual
DI Rail US Model: DI-US 48-5 Installation/Operation Manual Table of Contents Section age Section age Quick Start 2 1) General Information 4 Materials rovided 4 Optional quipment 4 2) Safety Information
More information1.4 N/1.4 D. Operating Instructions. 580 Mayer Street, Building #7, Bridgeville, PA phone fax
1.4 N/1.4 D Operating Instructions 580 Mayer Street, Building #7, Bridgeville, PA 15017 phone 412.206.0106 fax 412.206.0146 www.brightlines.com 2006 Brightline, L.P. Safety Warning: Do not dim a non-dim
More informationSAVE THESE INSTRUCTIONS
MILLENIUM METREX METEL SERIES INSTALLATION INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS DO NOT USE OUTDOORS. DO NOT MOUNT NEAR GAS OR ELECTRIC HEATERS. 1 APPLICATIONS EQUIPMENT
More informationHXE4B BATTERY POWERED CRIMP TOOL
Description The HXE4B Battery Powered Crimp Tool is a hand held, self contained crimp tool intended to crimp copper and aluminum cable with DMC Y dies. Safety Safety is essential in the use and maintenance
More informationHYGRODYNAMICS DIGITAL DEW POINT MONITOR PC BOARD MODEL 6392N & 6392N2 TABLE OF CONTENTS
HYGRODYNAMICS DIGITAL DEW POINT MONITOR PC BOARD MODEL 6392N & 6392N2 TABLE OF CONTENTS INTRODUCTION... 2 SPECIFICATIONS... 2 INSTALLATION... 3 PC Board Mounting...3 Sensor Installation...3 Manifold Assembly...4
More information2016 Lighting Catalog
2016 Lighting Catalog Innovative Lighting Solutions UL924 Shunt Relays Wireless Solutions 2016 Lighting Catalog Table of Contents UL924 Bypass / Shunt Relays 3 Wireless Devices 19 Light Controllers 24
More informationUser's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model
User's Manual High Voltage Megohmmeter Analog Insulation Tester plus AC Voltage and Continuity Tests Model 380353 Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects
More informationUltrasonic Level Switch
User Guide Revision A.0 Contents User Manual... 3 Wiring... 3 Basic Switch Operation... 3 Hysteresis Zone Preventing Relay Clatter.... 4 Training Your... 5 Training Button... 5 Training the - Level Below
More informationSB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320
Inlet Controller SB 2000 USER'S MANUAL AUTO OPEN MANUAL PUSH TO SEARCH NEXT STAG E CLOSE Aerotech, Inc. FORM: QM 1320 4215 Legion Dr. Mason, MI 48854-1036 USA Rev. 3, Sept. 1997 Ph. (517) 676-7070 Fax
More informationCBC-802 Plug-In Clutch/Brake Control with Solid State Switching
DIST. AUTORIZADO Plug-In Clutch/Brake Control with Solid State Switching P-29-5 19-0409 Service & Installation Instructions An Altra Industrial Motion Company DIST. AUTORIZADO Brake (Red) and clutch (Green)
More informationUser Guide. Model Insulation Tester / Megohmmeter. Introduction
User Guide Model 380363 Insulation Tester / Megohmmeter Introduction Congratulations on your purchase of Extech s Insulation Tester/Megohmmeter. The Model 380363 provides three test ranges plus continuity
More informationLightweight, On-Board, Power Tender: Models: 12V6A, 24V3A
Lightweight, On-Board, Power Tender: Models: 12V6A, 24V3A The Tender Light Weight On- Board 12 Volt, 6 Amp 24 Volt, 3 Amp GENERAL DESCRIPTION: The lightweight, on-board, power tender, battery charger is
More informationOwner s Manual POWER SOLUTION. AUTOMATIC CIRCUIT SWITCH. JTB Manufacturing, Inc. Part No Manufacture Date Year: 2013 Month:
POWER SOLUTION www.jtbmfg.com Owner s Manual JTB Manufacturing, Inc. Part No. 2010-100 Manufacture Date Year: 2013 Month: Serial Number Electrical Ratings 120VoltAC, 1 Phase, 50/60 Hz, 20 AMP Type 1 Enclosure
More informationSCC-MPPT Solar Charge Controller
Solar Charge Controller Quick Guide 200W 300W 400W 600W 850W V. 2.2 1. Introduction solar charge controller uses PWM-based DSP controller to keep the batteries regulated and prevent batteries from overcharging
More informationEMERGENCY ONE-LED TM SOLO TM NON MAINTAINED LED LAMP AND DRIVER KIT
Product description One-LED Solo TM is a non-maintained, self-contained LED emergency luminaire comprising an Omni-LED emergency LED driver, hinged rechargable battery and a flush-mount SELV lamp head.
More informationOperating Instructions
Important Information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect