TS93 EMF T/PT/TDE. Surface applied door closer

Size: px
Start display at page:

Download "TS93 EMF T/PT/TDE. Surface applied door closer"

Transcription

1 TS9 EMF T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer (no smoke detector) (EMF T) Push side track mount closer (no smoke detector) (EMF PT) Double egress track mount door closer(no smoke detector) (EMF TDE)

2 TABLE OF CONTENTS Closer overall Technical specifications Door templates Size selection chart Electrical specifications Closer setup Exploded parts list Handing of the door Surface closer configurations A. Installing the surface closer Pull side mount (T) 6-7 Push side mount (PT) 8-9 Double egress mount (TDE) 0- B. Adjustments Adjusting the closing speeds Adjusting the spring force Adjusting the hold open C. Electrical installation Wiring the electromagnet Installing the optional bypass switch D. Final set up Installing the cover Final testing Technical specifications Templates Contents NOTE: Refer to the included drawings for push side door closer, back plate mounting templating. NOTE: Refer to the included drawings for pull side door closer, back plate mounting templating. NOTE: Refer to the included drawings for double egress door closer, back plate mounting templating. Note. Drawing is not to scale.. Dimensions are in inches/[mm].. Hand door see image note.. Caution: sex nuts are required for attachment of components to unreinforced doors and to wood or plastic faced composite type fire doors, unless an alternative method is identified in the individual door manufacturer's listings.. Template is for -/ x -/ butt hinges & /" offset pivots 6. Maximum door opening degree is: T = 70 ; PT = 0 ; TDE = Minimum door width is: T = 0"; PT = "; TDE = ". 8. Hold open range with optional hold open kit is: T = 80 - ; PT = 80-9 ; TDE = The appropriate closer body styles are: T = "B" style; PT = "G" style; TDE = "B" style. 0. Arrows on closer mounting plate point upward. DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: dormaarchitectural@dorma.com / Reamstown, PA 767 Fax: Subject to change without notice

3 TS9 EMF T/PT/TDE Size selection charts TS9 EMF T Closer Interior/ Exterior Door Width '-" min. '-6" TS9 EMF T Interior N/A N/A TS96 EMF T Interior N/A N/A N/A N/A TS9 EMF PT Closer Interior/ Exterior Door Width '-8" min. '-0" TS9 EMF PT Interior N/A N/A TS96 EMF PT Interior N/A N/A N/A TS9 EMF TDE Closer Interior/ Exterior Door Width '-6" min. '-0" TS9 EMF TDE Interior N/A N/A TS96 EMF TDE Interior N/A N/A N/A '-0" '-6" '-6" '-6" '-0" '-0" '-0" '-6" '-6" '-6" '-0" '-0" '-0" Electrical specifications Electrical connection Apart from the broad range of DORMA accessories, other manufacturers offer various activators, locking devices, safety sensors and additional accessories that are compatible with TS9 EMF closers. External activation device minimum requirements In general external activation devices need to provide a normally closed alarm contact. Contact ratings Operating voltage with power supply via operator: V DC + 0% -% VAC +0% -% Maximum input current: VDC 66mA VAC 66mA Dry contact, normally open devices (such as push buttons or overhead sensors): Minimum requirements Operating voltage with power supply via operator: V DC +/- 0% Operating voltage with external power supply: 8 V AC/DC Current load for relay contact of locking device: A Power supply: V AC +/- 0% 0/60 Hz max 6.6 A Rated for continuous duty: electric strike: min. 0% Rated for continuous duty: motor lock: 00 % Power consumption for accessories: The operator will provide a maximum of. A at V DC for external accessories. Any additional power will require an external power supply in order to avoid malfunctions. Override Activation Inputs Note: These inputs bypass the mode switch and are always active. Dry contact, normally closed devices (frequently used to control systems with smoke and heat evacuation or building management systems): Use input terminals and and set parameter "d" to. Wet output devices with 8 to volts (such as telephone/ intercom systems): Use input terminals 7 and 7a. DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: dormaarchitectural@dorma.com / Reamstown, PA 767 Fax: Subject to change without notice

4 TS9 EMF T/PT/TDE Size selection charts TS9 EMF T Closer Interior/ Exterior '-" min. Door Width '-6" TS9 EMF T Interior N/A N/A TS96 EMF T Interior N/A N/A N/A N/A TS9 EMF PT Closer Interior/ Exterior Door Width '-8" min. TS9 EMF PT Interior N/A N/A TS96 EMF PT Interior N/A N/A N/A TS9 EMF TDE Closer Interior/ Exterior Door Width '-6" min. TS9 EMF TDE Interior N/A N/A TS96 EMF TDE Interior N/A N/A N/A '-0" '-0" '-0" '-6" '-6" '-6" '-0" '-0" '-0" '-6" '-6" '-6" '-0" '-0" '-0" DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: dormaarchitectural@dorma.com / Reamstown, PA 767 Fax: Subject to change without notice

5 TS9 EMF T/PT/TDE Closer setup Follow included template to properly prepare door and frame for all accessories of the closer installation. Know the swing of the door which is being installed prior to installation. Verify closer spring size prior to installation. See "Size selection chart" on page. Make sure door efficiently operates prior to installing closer. The surface closer is comprised of the following components.. Closer body. Main arm. Track assembly. Pinion. Cover and end caps 6. Track channel end cover Back plate 8. Closing/sweep speed adjustment 9. Latch speed adjustment 0. Backcheck adjustment. Delayed action adjustment 6 Handing of the door Left hand door (LH) Interior side of door 7 Right hand door (RH) Hinge Hinge Left hand reverse door (LHR) Exterior side of door Right hand reverse door (RHR) DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: dormaarchitectural@dorma.com / Reamstown, PA 767 Fax: Subject to change without notice

6 TS9 EMF T/PT/TDE Surface closer configurations The surface can be assembled in the following configurations. a. Pull side mount configuration (T): Closer body style "B" [left hand reverse door] b. Push side mount configuration (PT): Closer body style "G" [right hand door] c. Double egress mount configuration (TDE): Closer body style "B" [left hand reverse door] DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: / Reamstown, PA 767 Fax: Subject to change without notice 6

7 TS9 EMF T/PT/TDE A. Installing the surface closer: Pull side mount (T) Tools recommended Drill Bits Metal: No. & 0- Tap Wood: 9/6" # Phillips screwdriver /6" flat head screwdriver Jeweler's flat head screwdriver M Hex key Installing the track and backplate Electrical wiring outside wall Electrical wiring inside wall Reference template NOTE: For use on regular mount applications on the pull side of the door.. Orient the wire access plugs () away from the hinge (see step for orientation). Left hand reverse door. Remove the appropriate wire access plug from the track. If removing the frame side wire access plug, ensure it aligns with the through hole in the frame.. For wiring applications that are outside of the wall, screw a surface conduit () into the exterior wire plug hole. Away from hinge. Attach the track channel () to the frame through the end blocks with the two provided screws [/-0x" Phillips flathead screws or No. x-/" Phillips flathead wood screws] (). Left hand reverse door. Attach the back plate () to the mounting surface using the four screws [0-x/8" Phillips flathead screws or #0x" Phillips flathead wood screws] provided with the surface closer, using the st and rd holes of the plate. NOTE: Make sure arrows on plate point upward. 7 DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: dormaarchitectural@dorma.com / Reamstown, PA 767 Fax: Subject to change without notice

8 TS9 EMF T/PT/TDE Installing the surface closer Toward the hinge NOTE: Orient pinion () closest to hinge.. Attach the closer body () to the plate using the four screws [Mx7mm Phillips flathead] () provided with the plate itself.. Attach the main arm () to the top pinion with an M6x0 socket head cap screw () and an M8 lock washer () using an M hex key. Be sure the main arm is parallel to the door during application. Left hand reverse door 6 Left hand reverse door 6. Align the arm () with the slide shoe of the track channel. 6. Attach with one shoulder bolt () using an M hex key. DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: dormaarchitectural@dorma.com / Reamstown, PA 767 Fax: Subject to change without notice 8

9 TS9 EMF T/PT/TDE A. Installing the surface closer: Push side mount (PT) Tools recommended Drill Bits Metal: No. & 0- Tap Wood: 9/6" # Phillips screwdriver /6" flat head screwdriver Jeweler's flat head screwdriver M Hex key /" or mm box wrench Installing the track and backplate Towards the hinge Right hand door Reference template NOTE: For use on soffit mount applications on the push side of the door.. Orient the open end of the track () towards the hinge.. Attach the track channel () to the soffit with one provided screw [one /-0x-/" Phillips flathead screw or one #x-" Phillips flathead wood screw] () and through the track with one provided screw [one /-0x/8" Phillips pan head screw or one #x" Phillips pan head wood screw] ().. Attach the back plate () to the mounting surface using the four screws [0-x/8" Phillips flathead screws or #0x" Phillips flathead wood screws] provided with the surface closer, using the st and rd holes of the plate. NOTE: Make sure arrows on plate point upward. 9 DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: dormaarchitectural@dorma.com / Reamstown, PA 767 Fax: Subject to change without notice

10 TS9 EMF T/PT/TDE Installing the surface closer Toward the hinge NOTE: Orient pinion () closest to hinge.. Attach the closer body () to the plate using the four screws [Mx7mm Phillips flathead screws] () provided with the plate itself.. Using an adjustable wrench (and looking up at the bottom of the closer): Left hand door - turn the bottom pinion counterclockwise. Right hand door - turn the bottom pinion clockwise.. Attach the main arm () to the top pinion with an M6x0 socket head cap screw () and an M8 lock washer () using an M hex key.. Right hand door Be sure the main arm is parallel to the door during application. Right hand door. Align the arm () with the slide shoe of the track channel.. Attach with one shoulder bolt () using an M hex key. DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: dormaarchitectural@dorma.com / Reamstown, PA 767 Fax: Subject to change without notice 0

11 TS9 EMF T/PT/TDE A. Installing the surface closer: Double egress mount (TDE) Tools recommended Drill Bits Metal: No. & 0- Tap Wood: 9/6" # Phillips screwdriver /6" flat head screwdriver Jeweler's flat head screwdriver M Hex key Installing the track and backplate Electrical wiring outside of the wall Electrical wiring inside wall Reference template NOTE: For use on regular mount applications on the pull side of the door.. Orient the wire access plugs () away from the hinge.. Remove the appropriate wire access plug () from the track (see step for orientation). Left hand reverse door If removing the frame side wire access plug, ensure it aligns with the through hole in the frame.. For wiring applications that are outside of the wall, screw a surface conduit () into the exterior wire plug hole. Away from hinge. Attach the track channel () to the frame through the end blocks with two provided screws [/-0x" Phillips flathead screws or No. x-/" Phillips flathead wood screws.] (). Left hand reverse door. Attach the back plate () to the mounting surface using the four screws [0-x/8" Phillips flathead screws or #0x" Phillips flathead wood screws] provided with the surface closer, using the st and rd holes of the plate. NOTE: Make sure arrows on plate point upward. DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: dormaarchitectural@dorma.com / Reamstown, PA 767 Fax: Subject to change without notice

12 TS9 EMF T/PT/TDE Installing the surface closer Toward the hinge NOTE: Orient pinion () closest to hinge.. Attach the closer body () to the plate using the four screws [Mx7mm Phillips flathead screw] () provided with the plate itself.. Attach the main arm () to the top pinion with an M6x0 socket head cap screw () and an M8 lock washer () using an M hex key. Be sure the smaller portion () of the main arm is angled approximately away from the door during application. Left hand reverse door / Top view Left hand reverse door 6 6. Align the arm () with the slide shoe of the track channel. 6. Attach with one shoulder bolt () using an M hex key. DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: dormaarchitectural@dorma.com / Reamstown, PA 767 Fax: Subject to change without notice

13 TS9 EMF T/PT/TDE B. Adjustments Confirm closer spring size prior to making any closing speed adjustments. Do not back valves out beyond closer casting. Maximum opening angles are listed on page. Door should close in to 6 seconds from 90º. Do not close valves completely. Adjusting the closing speeds: sweep, latch or backcheck and delayed actions Delayed action [Sweep] [Latch] [Backcheck] Backcheck Sweep [Delayed action] Latch Decrease Increase Sweep & Latch Speed. Adjust the sweep speed () for the area from the maximum open position to 0. Maximum opening degrees are listed on page. Increase sweep speed: Turn valve counter-clockwise Decrease sweep speed: Turn valve clockwise.. Adjust the latch speed () for the area from 7-0. Increase latch speed: Turn valve counter-clockwise. Increase Decrease. Adjust the backcheck () for the area from 70 to the maximum opening. Increase resistance: Turn valve clockwise Decrease resistance: Turn valve counter-clockwise.. Adjust the delayed action () for the area from 0 to 70. Increase delayed action: Turn valve clockwise Backcheck & Delayed actions Decrease delayed action: Turn valve counter-clockwise Adjusting the spring force Increase Decrease CLOSER TYPE MAX DOOR WEIGHT (LBS) SPRING SIZE FULL TURNS OF SPRING ADJUSTER + TS TS TS9 NOTE: Supplied with a size spring setting. Adjust according to chart. TS96 NOTE: Supplied with a size 6 spring setting. Adjust only if more spring tension is required to positively close and latch door. DOOR WIDTH FULL TURNS OF CLOSER INT. EXT. SPRING ADJUSTER SIZE ' '6" + '6" ' +9 ' '6" + NOTE: DO NOT ADJUST SPRING LOWER THAN SIZE DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: dormaarchitectural@dorma.com / Reamstown, PA 767 Fax: Subject to change without notice

14 TS9 EMF T/PT/TDE Adjusting the hold open Less hold open angle Greater hold open angle NOTE: Hold open position is preset at approximately 90.. Loosen the set screws () using a /" hex wrench.. Slide the hold open to the desired position.. Tighten the screws to desired the position.. Turn the screw () with a screw driver to set the force needed to manually disengage the hold open: Clockwise = increase force Counter clockwise = decrease force C. Electrical installation Incoming power supply and unit voltage type: VAC/DC. CAUTION: DO NOT CONNECT UNIT TO 0 VAC. Improper voltage to unit will result in damage to the unit and will void the warranty. Note: An auxiliary door stop must be installed to limit the maximum degree of door swing. Failure to do so may result in damage to the unit. All wiring must comply with national, state, and local electrical codes. Wiring the electromagnet To U.L. listed alarm control unit or smoke detector.. Slide the track channel end cover () to allow access to the wire connectors ().. Connect the power supply () to the terminal block (). Note: Terminal block may be removed for easier access. Note: The connection is not polarity dependent.. Return track channel end cover to the closed position. To U.L. listed alarm control unit or smoke detector. For the TS9 EMF TP only.. Slide the track channel end cover () into the track.. Insert the end cap () into the end of the track.. Secure the end cap with one screw [one #x-" Phillips flathead wood screw or one /-0x-/" Phillips flathead screw] ().. Return track channel end cover to the closed position. DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: dormaarchitectural@dorma.com / Reamstown, PA 767 Fax: Subject to change without notice

15 TS9 EMF T/PT/TDE Installing the optional bypass switch, TS9 EMF T. Slide the track channel end cover () to allow access to the track interior.. Attach the bracket () to the track with two screws ().. Assemble the bypass switch ().. Disconnect one power supply wire () from the terminal block ().. Connect the disconnected power supply wire to one of the bypass switch wires ().. Connect the other bypass switch wire () into the empty connector of the terminal block.. Return track channel end cover to the closed position. Installing the optional bypass switch, TS9 EMF PT 6. Fasten the extension piece () into the track with the provided cap head combo screw ().. Connect the switch () to the power supply wires () using wire nuts ().. Place the end cap (6) into the extension piece and fasten to the frame with the provided flat head screw.. Slide the track channel end cover () into place over the bypass switch (). DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: / Reamstown, PA 767 Fax: Subject to change without notice

16 TS9 EMF T/PT/TDE D. Final set up Installing the covers. Snap both end covers () into place.. Remove the un-needed tab (), and snap the closer body cover () into place.. Attach with a -0 Phillips pan head screw ().. Slide the track channel end cover () away from the closer until it comes up against the end of the track. Final testing The unit must be tested after installation by the end user. The unit must be periodically tested in conjuncture with the testing of the entire fire alarm system.. After the installation is completed, recheck all the connection.. Apply power to the units.. Open the door so the slide shoe engages with the hold open mechanism. The end user is responsible for the adjustment and maintenance of the unit to retain the system in working order. Note: If the closer is used in conjunction with a detectored unit, trip the test switch on the main closer detector as explained in the test procedure for that unit. After a short delay time, the hold open solenoid of both units will release and the doors will close. Resetting the test switch will allow the units to return to standby.. Advise fire officials prior to testing the unit.. Activate the system. Confirm the functioning of the solenoids. DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: dormaarchitectural@dorma.com / Reamstown, PA 767 Fax: Subject to change without notice 6

17 DORMA USA, INC. DORMA DRIVE, DRAWER AC REAMSTOWN, PA 767 TOLL-FREE: FAX: /0, Subject to change without notice

TS9356 PKT 90/119. Surface applied door closer. Installation instructions: Pocket door track mount in 90 /119 pocket (Closer on wall)

TS9356 PKT 90/119. Surface applied door closer. Installation instructions: Pocket door track mount in 90 /119 pocket (Closer on wall) TS96 PKT 90/9 Surface applied door closer Installation instructions: Pocket door track mount in 90 /9 pocket (Closer on wall) TABLE OF CONTENTS Closer overall Technical specifications Door templates Closer

More information

TS93 PT/PTH. Surface applied door closer. Installation instructions: Push side track mount with dead stop (PT) Optional hold open (PTH)

TS93 PT/PTH. Surface applied door closer. Installation instructions: Push side track mount with dead stop (PT) Optional hold open (PTH) Surface applied door closer Installation instructions: Push side track mount with dead stop (PT) Optional hold open (PTH) TABLE OF CONTENTS Technical specifications Size selection chart 2 Closer setup

More information

ED900. Low energy operator. Installation instructions: T/slide channel/pull arm mounting

ED900. Low energy operator. Installation instructions: T/slide channel/pull arm mounting Low energy operator Installation instructions: T/slide channel/pull arm mounting TABLE OF CONTENTS Operator overall Accessories External activation device minimum requirements Contact ratings Locking device

More information

Holder/Release Devices with Integral Door Closers DORMA EMF/ EMR

Holder/Release Devices with Integral Door Closers DORMA EMF/ EMR Holder/Release Devices with Integral Door Closers DORMA EMF/ EMR DORMA EMR Holder/Release Device with Integral Detector The DORMA EMR Series holder/release device incorporates a photoelectric detector

More information

*24771* 4040SE DE Sentronic. 1 Voltage. 7 Regulation. 2 Track. 8 Door Closer Cover. 3 Spring Power. 4 Arm Installation. 5 Arm Screw.

*24771* 4040SE DE Sentronic. 1 Voltage. 7 Regulation. 2 Track. 8 Door Closer Cover. 3 Spring Power. 4 Arm Installation. 5 Arm Screw. *2477* 2477 SE Egress 4040SE DE Sentronic Installation Instructions This closer features mounting options for both standard and step-down double egress frames. Before beginning, determine which type of

More information

ASSA ABLOY MPI (Infinite Hold Open Range) Support Unit Models. Multi-Point Electromechanical Overhead Concealed Closer Holder Releasing Device

ASSA ABLOY MPI (Infinite Hold Open Range) Support Unit Models. Multi-Point Electromechanical Overhead Concealed Closer Holder Releasing Device Overhead Concealed Closer Holder Releasing Device with Rigid Slide Arm For wood or metal doors 1-3/4 to 2-1/4" (45-57mm) thick Hung in a hollow metal frame Standard butt hinges Typical Installation One

More information

Surface Applied Door Closer and Coordinator System DORMA GSR

Surface Applied Door Closer and Coordinator System DORMA GSR Surface Applied Door Closer and Coordinator System DORMA GSR DORMA GSR Surface Applied Door Closer and Coordinator System The TS93 GSR in Contur Design combines exceptionally smooth, efficient door control

More information

Installation Instructions Series 78-B/FHA Hold Open

Installation Instructions Series 78-B/FHA Hold Open Installation Instructions Series 78-B/FHA Hold Open Traditional Style Door Closers Read these instructions before proceeding with the installation. Make sure that the door opens the full angle desired

More information

Series 9540 J9540. Installation Instructions Multi-Sized 1 to 6 Non-Hold Open. Regular Arm Applications. Parallel Arm Applications

Series 9540 J9540. Installation Instructions Multi-Sized 1 to 6 Non-Hold Open. Regular Arm Applications. Parallel Arm Applications Series 940 J940 ASSA JL940 ABLOY Installation Instructions Multi-Sized to 6 Non-Hold Open Regular Arm Applications Left Hand Regular Arm Application Contents Page Template Template with 984-8 Drop Plate

More information

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING CAUTION 80-957-00-00 (08-0) Series 570 Openings 85 to 0 or to 70 Double Lever Arm Application for Frame Reveals (76) to 7 (78mm)* Stop (Push) Side of Installation 5700 LEO Operator Installation Instructions

More information

ASSA ABLOY Series Multi-Point Hold Open Installation and Instruction Manual

ASSA ABLOY Series Multi-Point Hold Open Installation and Instruction Manual Pull Side Applications with Slide Track (7210, 7250) (see page 7 for template) 7200 Series Multi-Point Hold Open Installation and Instruction Manual 3 1 Push Side Applications with Double Lever Arms (7220,

More information

ASSA ABLOY Universal Door Closers

ASSA ABLOY Universal Door Closers Installation Instructions For Non-Hold Open or A Hold Open Arm Options DC6200 Series DC6400 Series Multi-Sized thru 6 Half-Size thru 6 Regular Arm Parallel Arm Universal Door Closers Jamb Mount See pages

More information

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING CAUTION 80-957-00-00 (08-0) Series 570 Door Openings 85 to 0 or to 80 Adjustable Arm and Slide Track Application Maximum Hinge Side Frame Reveal to /8 (mm) Hinge (Pull) Side of Door Installation 5700 LEO

More information

Surface Applied Door Closers DORMA TS93

Surface Applied Door Closers DORMA TS93 Surface Applied Door Closers DORMA TS93 DORMA TS93 Surface Applied Door Closers The TS93 System in Contur Design represents the pinnacle of surface applied closers because of its unique cam and roller

More information

*24213* 4040-SE Sentronic. 1 Voltage. 6 Adjusting Hold-Open Door Position. 7 Regulation. 2 Tracking. 8 Door Closer Cover.

*24213* 4040-SE Sentronic. 1 Voltage. 6 Adjusting Hold-Open Door Position. 7 Regulation. 2 Tracking. 8 Door Closer Cover. *223* 223 00-SE Sentronic Installation Instructions This closer features two mounting options. Before beginning, determine which type of mounting best applies to your application, or had been specified

More information

TS93. Surface Applied Door Closers

TS93. Surface Applied Door Closers Surface Applied Door s CONTENTS Surface Applied Door s Technical Details 3 Specifications 3 Features 3 Additional Models 4 How to Order 5 Technical Drawings Track Installation Jamb Mounted Slide Track

More information

Surface Applied Door Closers DORMA TS93

Surface Applied Door Closers DORMA TS93 Surface Applied Door Closers DORMA TS93 DORMA TS93 Surface Applied Door Closers The TS93 System in Contur Design represents the pinnacle of surface applied closers because of its unique cam and roller

More information

FIRE/LIFE SAFETY SERIES PRODUCT SELECTION GUIDE

FIRE/LIFE SAFETY SERIES PRODUCT SELECTION GUIDE FIRE/LIFE SAFETY SERIES PRODUCT SELECTION GUIDE SENTRONIC Series LCN closer/holders combine heavy duty closers with electrically controlled hold-open functions to control fire and smoke barrier doors.

More information

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY 00 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) Track Assembly (0-) / Replacement

More information

7100SZ Series SafeZone Installation and Instruction Manual

7100SZ Series SafeZone Installation and Instruction Manual 7100SZ Series SafeZone Installation and Instruction Manual Patent Pending 80-9371-0081-00 (10-10) Pull Side Applications with Slide Track (7110SZ, 7150SZ) (see page 5 for template) 3 1 Push Side Applications

More information

DC3210 Series. Multi-Sized 1 thru 6 DEEP REVEAL APPLICATION WITH M103 OPTION(615F59 CLAMP KIT) Recommended Closer Size

DC3210 Series. Multi-Sized 1 thru 6 DEEP REVEAL APPLICATION WITH M103 OPTION(615F59 CLAMP KIT) Recommended Closer Size DC310 Series Multi-Sized 1 thru 6 Installation Instructions Universal Closers with Heavy Duty Spring Stop Parallel Arms A11 - Non- Arm A1 - Arm STANDARD APPLICATION WITH DEEP REVEAL APPLICATION WITH M103

More information

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES PRODUCT SELECTION GUIDE SENTRONIC Series LCN closer/holders combine heavy duty closers with electrically controlled hold-open functions to control fire and smoke

More information

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY 0 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) / Replacement Motor Key (00KEY) Rod

More information

These door closers should NOT be installed on the exposed side (weather side) of exterior doors.

These door closers should NOT be installed on the exposed side (weather side) of exterior doors. 500 Series Non-Hold Open Door Closer Instructions vailable in Sizes,, and 5 Regular rm See Page n incorrectly installed or improperly adjusted door closer can cause property damage or personal injury.

More information

D O O R C L O S E R S

D O O R C L O S E R S DOOR CLOSERS DOOR CLOSER Philadelphia Hardware Group, Inc. is presenting the finest ADVANTAGE surface mounting door closers certified by BHMA including: Multi-size door closer: 9000, 8000, 6000, 6000S

More information

LCN 4310ME SERIES FEATURES HINGE (PULL) SIDE MOUNTING. The 4310ME SENTRONIC is a. heavy duty, electrically controlled

LCN 4310ME SERIES FEATURES HINGE (PULL) SIDE MOUNTING. The 4310ME SENTRONIC is a. heavy duty, electrically controlled HINGE (PULL) SIDE MOUNTING The 4310ME SENTRONIC is a heavy duty, electrically controlled closer/holder designed to provide infinitely adjustable hold-open for FEATURES fire and smoke barrier doors. Door

More information

D o o r C l o s e r s

D o o r C l o s e r s Door Closers DOOR CLOSER Philadelphia Hardware Group, Inc. is presenting the fi nest ADVANTAGE surface mounting door closers for your various application demands. There are Multi-size door closer: 9000,

More information

NON-SIZED SIZED HANDED

NON-SIZED SIZED HANDED HINGE (PULL) SIDE MOUNTING 4310ME SERIES The 4310ME SENTRONIC is a heavy duty, electrically controlled closer/holder designed to provide infinitely adjustable hold-open for fire and smoke barrier doors.

More information

LCN 4310ME SERIES HINGE (PULL) SIDE MOUNTING. The 4310ME SENTRONIC is a. heavy duty, electrically controlled. closer/holder designed to provide

LCN 4310ME SERIES HINGE (PULL) SIDE MOUNTING. The 4310ME SENTRONIC is a. heavy duty, electrically controlled. closer/holder designed to provide HINGE (PULL) SIDE MOUNTING The 4310ME SENTRONIC is a heavy duty, electrically controlled closer/holder designed to provide FEATURES infinitely adjustable hold-open for fire and smoke barrier doors. Door

More information

5600 Series Power Operator Installation and Instruction Manual

5600 Series Power Operator Installation and Instruction Manual 5600 Series Power Operator Installation and Instruction Manual 80-956-000-00 (08-) 5 ASSA ABLOY 6 Item No. Description Motor (5600M) Cover (5600COV) Control Inverter (5600IN) Power Supply VDC (5600PS)

More information

Power drill Center punch Wire stripper

Power drill Center punch Wire stripper Pull Side Applications with Slide Track (7110SZ, 7150SZ) (see page 7 for template) 7100SZ Series SafeZone Installation and Instruction Manual Patent Pending 3 1 Push Side Applications with Double Lever

More information

HOW TO TELL HAND OF DOOR:

HOW TO TELL HAND OF DOOR: *15022* 4410ME Series 15022 Door closer with electronic release & Multi-point hold open Installation Instructions 1 Closer Installation 1a Closer Information Closer is handed at the factory. The hand of

More information

*24191* 4040SEL Sentronic. 35 ft-lbs 48 N-m 62 N. Installation CAUTION. Customer Service. Installation Instructions

*24191* 4040SEL Sentronic. 35 ft-lbs 48 N-m 62 N. Installation CAUTION. Customer Service. Installation Instructions *24191* 24191 4040SEL Sentronic Installation Instructions Backcheck = Maximum Opening Force 35 ft-lbs 48 N-m 62 N Latch Backcheck Main To Increase Power 5/32 Hex Wrench Main Latch 1a 1b 1c 1d This closer

More information

ASSA ABLOY Universal Door Closers with Heavy Duty Spring Stop Parallel Arms

ASSA ABLOY Universal Door Closers with Heavy Duty Spring Stop Parallel Arms DC610 Series Multi-Sized 1 thru 6 DC610 Series Half-Size 1 thru 6 Installation Instructions Universal Closers with Heavy Duty Spring Stop Parallel Arms A11 - Non- Arm A1 - Arm STANDARD APPLICATION WITH

More information

U1500. Surface Applied Door Closers

U1500. Surface Applied Door Closers U1500 Surface Applied Door Closers U1500 SURFACE APPLIED DOOR CLOSERS U1500 SERIES SURFACE CLOSERS CONTENTS U1500 Surface Applied Door Closers Technical Details/Specifications 3 Features 3 Ordering Guide

More information

D-1610/D-1611 SERIES: DOOR CLOSERS. D-1610/D-1611 Series. Door Closers. Trusted experts. Proven reliability. Simply STANLEY.

D-1610/D-1611 SERIES: DOOR CLOSERS. D-1610/D-1611 Series. Door Closers. Trusted experts. Proven reliability. Simply STANLEY. D-1610/D-1611 SERIES: DOOR CLOSERS D-1610/D-1611 Series Door Closers Trusted experts. Proven reliability. Simply STANLEY. TABLE OF CONTENTS General Information...2, 3 Standard Application...4 Parallel

More information

5700 Series Power Operator Hinge (Pull) Side Mount Installation and Instruction ASSA Manual ABLOY

5700 Series Power Operator Hinge (Pull) Side Mount Installation and Instruction ASSA Manual ABLOY 5700 Series Power Operator Hinge (Pull) Side Mount Installation and Instruction ASSA Manual ABLOY 80-957-000-00 (06-5) Patents 5,88,97; 7,6,096; 7,8, 6 5 0 8 7 9 Item No. Description Back plate Door Closer

More information

Hinge (Pull) Side Door Application DC6230 Series Multi-Sized 1 thru 6 DC6430 Series Half-Size 1 thru 6. Door Mounted DC6230 & DC6430

Hinge (Pull) Side Door Application DC6230 Series Multi-Sized 1 thru 6 DC6430 Series Half-Size 1 thru 6. Door Mounted DC6230 & DC6430 Installation Instructions Universal Door Closers Slide Track Application (0 Maximum Door Swing) (standard)- N.H.O. Bumper Stop A - H.O. Bumper Stop Track - Pull Side See pages 2 & Hinge (Pull) Side Door

More information

Surface Applied Door Closers DORMA 7400

Surface Applied Door Closers DORMA 7400 Surface Applied Door Closers DORMA 7400 DORMA 7400 Table of Contents Technical Details and Specifications.................. 3 How to Order................................... 4 7400 Series Technical Drawings

More information

LCN 4010T SERIES HINGE (PULL) SIDE

LCN 4010T SERIES HINGE (PULL) SIDE HINGE (PULL) SIDE MOUNT The 4010T SMOOTHEE is LCN s best performing heavy duty track closer designed specifically for interior doors in institutional and other rugged high traffic applications. FEATURES

More information

CONCEALED CLOSER SERIES

CONCEALED CLOSER SERIES CONCEALED CLOSER SERIES APPLICATIONS n For aluminum, hollow metal, or wood doors and frames. n Can be used with hinge or pivot mounted door. n Closers for 4 or minimum 1-3/4 head frame or 4 top rail. n

More information

Surface Applied Door Closers

Surface Applied Door Closers 7300 Surface Applied Door Closers Table of Contents Technical Details and Specifications.................. 3 How to Order................................... 4 Technical Drawings Regular round form arm.........................

More information

NON-SIZED SIZED HANDED

NON-SIZED SIZED HANDED 4410ME SERIES TOP JAMB (PUSH SIDE) MOUNTING The 4410ME SENTRONIC is a heavy duty, electrically controlled closer/holder designed to provide infinitely adjustable hold-open for fire and smoke barrier doors.

More information

Surface Applied Door Closers

Surface Applied Door Closers 7300 Equia nestotatus enis 015 Surface Applied Door s Lecest Suntur Orem fuga Equia nestotatus Disciisi nisquissus Nequisi Voloreptatae Consecumque soloribus Iminveria volorum dormakaba 7300 surface applied

More information

5700 Series Power Operator Stop (Push) Side Mount Installation and Instruction

5700 Series Power Operator Stop (Push) Side Mount Installation and Instruction 5700 Series Power Operator Stop (Push) Side Mount ASSAManual ABLOY Installation and Instruction 80-957-0005-00 (06-5) Patents 5,88,97; 7,6,096; 7,8, 5 6 0 8 7 9 -/8 () Item No. Description Back plate Door

More information

*HINGE (pull) side mount shown

*HINGE (pull) side mount shown CLOSER MOUNTS *HINGE (PULL) SIDE TOP JAMB (PULL SIDE) STOP FACE (PUSH SIDE) The 4040T SMOOTHEE is LCN s most flexible heavy duty track closer designed specifically for interior doors in institutional and

More information

5300 Series. Architectural Commercial Door Control

5300 Series. Architectural Commercial Door Control 5300 Series Architectural Commercial Door Control 5300 SERIES Architectural Commercial Door Control SUGGESTED ARCHITECTURAL SPECIFICATIONS All door closers shall be narrow projection American Eagle 5300

More information

Model 2300JL Installation Guide

Model 2300JL Installation Guide Model 2300JL Installation Guide POWER ACCESS CORPORATION 4 HERSHEY DRIVE, DOCK 4 ANSONIA, CT 06401 800-344-0088 WEBSITE: www.power-access.com EMAIL: salesinfo@power-access.com 1 STANDARD PARTS MODEL 2300JL

More information

DOUBLE LEVER ARM DOUBLE LEVER ARM SINGLE LEVER ARM 5010 SINGLE LEVER ARM

DOUBLE LEVER ARM DOUBLE LEVER ARM SINGLE LEVER ARM 5010 SINGLE LEVER ARM SERIES PRODUCT SELECTION GUIDE The concealed LCN closers feature a modern design for concealment in either the head frame or top rail of the door. This guide is based on the desired mounting of the closer.

More information

Model 2300DL Installation Guide

Model 2300DL Installation Guide Model 2300DL Installation Guide POWER ACCESS CORPORATION 4 HERSHEY DRIVE, DOCK 4 ANSONIA, CT 06401 800-344-0088 WEBSITE: www.power-access.com EMAIL: salesinfo@power-access.com 1 STANDARD PARTS MODEL 2300DL

More information

Multi-point closer/holder with motion sensor 7100SZ DOOR CLOSER CATALOG

Multi-point closer/holder with motion sensor 7100SZ DOOR CLOSER CATALOG Multi-point closer/holder with motion sensor 7100SZ S E R I E S DOOR CLOSER CATALOG INTRODUCTION The 7100 Series SafeZone door closer safeguards occupants throughout a variety of facilities with the detection

More information

7100SZ SERIES. Multi-Point Closer/Holder with Motion Sensor

7100SZ SERIES. Multi-Point Closer/Holder with Motion Sensor safezone Multi-Point Closer/Holder with Motion Sensor introduction Designed with safety in mind, SafeZone takes door closers to a higher level. SafeZone uses a multi-point, electromechanical closer and

More information

CONCEALED CLOSER SERIES

CONCEALED CLOSER SERIES CLOSER SERIES PRODUCT SELECTION GUIDE The concealed LCN closers feature a modern design for concealment in either the head frame or top rail of the door. This guide is based on the desired mounting of

More information

NON-SIZED SIZED HANDED

NON-SIZED SIZED HANDED 4040SE SERIES n Standard 4040SE Series closer shipped with a standard arm, 24V or 120V (please specify) SE track, standard plastic clip-on cover, and wood and machine screw pack. SEL tracks are optional,

More information

MOUNTING FINISH COVER CYLINDER **ARM FUNCTION REGULAR (DOUBLE) DESIGNER METAL NON-HANDED NON-SIZED

MOUNTING FINISH COVER CYLINDER **ARM FUNCTION REGULAR (DOUBLE) DESIGNER METAL NON-HANDED NON-SIZED HINGE (PULL) SIDE MOUNT LCN 4010 SERIES The 4010 SMOOTHEE is LCN s best performing heavy duty closer designed specifically for institutional and other rugged high traffic applications. FEATURES Ten Million

More information

HIGH SECURITY CLOSERS SERIES

HIGH SECURITY CLOSERS SERIES HIGH SECURITY CLOSERS SERIES PRODUCT SELECTION GUIDE High Security LCN closers feature a vandal resistant design engineered for each application, easy installation, and superior performance. This guide

More information

7100SZ Series SafeZone. Multi-Point Closer/Holder with Motion Sensor

7100SZ Series SafeZone. Multi-Point Closer/Holder with Motion Sensor 7100SZ Series SafeZone Multi-Point Closer/Holder with Motion Sensor Page Revised Electronically 8/11 7100SZ Series SafeZone INTRODUCTION Designed with safety in mind, SafeZone takes door closers to a higher

More information

Surface Applied Door Closers

Surface Applied Door Closers 7400 Surface Applied Door s 7400 SURFACE APPLIED DOOR CLOSERS 7400 SERIES SURFACE CLOSERS CONTENTS CONTENTS The 7400 Series closers offer modern styling and versatility while providing safe and reliable

More information

7100SZ Series SafeZone. Multi-Point Closer/Holder with Motion Sensor

7100SZ Series SafeZone. Multi-Point Closer/Holder with Motion Sensor 7100SZ Series SafeZone Multi-Point Closer/Holder with Motion Sensor INTRODUCTION Designed with safety in mind, SafeZone takes door closers to a higher level. SafeZone uses a multi-point, electromechanical

More information

ROFU TJ 152-A. Y ALE SECURITY GROUP 50BC Series Door Closer. 50BC Series Door Closers. Sizing Chart for Installations. Ordering Information

ROFU TJ 152-A. Y ALE SECURITY GROUP 50BC Series Door Closer. 50BC Series Door Closers. Sizing Chart for Installations. Ordering Information ROFU 50BC Series Door Closers Specifications U.L. Listing All Yale 50 Series Door Closers with non-hold-open arms are listed by Underwriters Laboratories, Inc. for use on labeled fire doors. Tri-Pack Closer

More information

LCN 4040SE SERIES FEATURES HINGE (PULL) SIDE MOUNTING

LCN 4040SE SERIES FEATURES HINGE (PULL) SIDE MOUNTING HINGE (PULL) SIDE MOUNTING Standard 4040SE series closer shipped with a standard arm, 24V or 120V (please specify) SE track, standard plastic clip-on cover, and wood and machine screw pack. SEL tracks

More information

HIGH SECURITY SERIES

HIGH SECURITY SERIES HIGH SECURITY SERIES PRODUCT SELECTION GUIDE High Security LCN closers feature a vandal resistant design engineered for each application, easy installation, and superior performance. This guide is based

More information

Power Supplies DORMA PS

Power Supplies DORMA PS Power Supplies DORMA PS DORMA PS Power Supplies Main System On/Off or Fire Panel Relay - The power supply output voltage can be controlled by the main system on/off control relay which accepts a closed

More information

PULL SIDE MOUNTED PUSH SIDE MOUNTED DOUBLE LEVER ARM LEVER ARM P DOUBLE LEVER ARM SINGLE LEVER ARM 4110T 4210T*

PULL SIDE MOUNTED PUSH SIDE MOUNTED DOUBLE LEVER ARM LEVER ARM P DOUBLE LEVER ARM SINGLE LEVER ARM 4110T 4210T* 4000 SERIES PRODUCT SELECTION GUIDE Surface mounted 4000 Series LCN closers feature a modern design engineered for each application, easy installation, and superior performance. This guide is based on

More information

4310ME Series. Features E25. Special Templates. Grade 1 - ANSI A156.15, UL 10C, ADA, 100 Hour Salt Spray, Meets BAA - Buy American Act, NFPA 101

4310ME Series. Features E25. Special Templates. Grade 1 - ANSI A156.15, UL 10C, ADA, 100 Hour Salt Spray, Meets BAA - Buy American Act, NFPA 101 Features The 4310ME SENTRONIC is a heavy duty, electrically controlled closer/holder designed to provide infinitely adjustable hold-open for fire and smoke barrier doors. Door is held open until current

More information

5300 Series. Architectural Door Control

5300 Series. Architectural Door Control 5300 Series Architectural Door Control 5300 SERIES ARCHITECTURAL STYLE COMMERCIAL DOOR CONTROL SUGGESTED ARCHITECTURAL SPECIFICATIONS All door closers shall be narrow projection American Eagle 5300 Series

More information

5300 Series 5300 SERIES

5300 Series 5300 SERIES 5300 Series Hager 5300 Series Grade 1 door closer is ideal for schools, hospitals, and other high abuse and high traffic environments. It is constructed of an aluminum alloy and provides smooth door control.

More information

5100 Series. Architectural Door Control

5100 Series. Architectural Door Control 5100 Series Architectural Door Control 5100 SERIES ARCHITECTURAL STYLE COMMERCIAL DOOR CONTROL SUGGESTED ARCHITECTURAL SPECIFICATIONS All door closers shall be American Eagle 5100 Series with full rack

More information

*4110 HCUSH mount shown

*4110 HCUSH mount shown *PARALLEL ARM (PUSH SIDE) MOUNT The 4110 SMOOTHEE is LCN s best performing heavy duty closer designed specifically for institutional and other rugged high traffic applications. FEATURES Standard 4110 series

More information

High Security Closers Series

High Security Closers Series High Security Closers APPLICATIONS n For any concealed or surface mounted installation subject to potential abuse or vandalism. n For correctional, aluminum, hollow metal, or wood doors and frames. n Can

More information

stanley door closers d-4550/d-4551 D-4550 / D-4551 SERIES DOOR CLOSERS

stanley door closers d-4550/d-4551 D-4550 / D-4551 SERIES DOOR CLOSERS stanley door closers d-4550/d-4551 D-4550 / D-4551 SERIES DOOR CLOSERS 1 General InForMatIon table of contents Page General Information... 2 4 How To Order...4 Standard (Pull) Application...5 Parallel

More information

Floor-Concealed Door Closers DORMA BTS75V

Floor-Concealed Door Closers DORMA BTS75V Floor-Concealed Door Closers DORMA BTS75V Floor-Concealed Door Closers Dependable and Versatile Floor-Concealed Closer The BTS75V Series of floor-concealed door closers offer adaptability to almost any

More information

Floor-Concealed Door Closers DORMA BTS80

Floor-Concealed Door Closers DORMA BTS80 Floor-Concealed Door Closers DORMA BTS80 Floor-Concealed Door Closers Dependable and Versatile Floor-Concealed Closer The BTS80 Series of floor-concealed door closers offer adaptability to almost any installation.

More information

4000 Series mounted closers

4000 Series mounted closers 4000 mounted closers APPLICATIONS n For aluminum, hollow metal, or wood swinging doors and frames. n Can be used with hinge or pivot mounted door. n Adapter plates and other installation accessories available

More information

PUSH SIDE M O U N T E D PULL SIDE M O U N T E D D O U B L E LEVER ARM LEVER ARM P D O U B L E LEVER ARM S I N G L E LEVER ARM

PUSH SIDE M O U N T E D PULL SIDE M O U N T E D D O U B L E LEVER ARM LEVER ARM P D O U B L E LEVER ARM S I N G L E LEVER ARM 4000 SERIES PRODUCT SELECTION GUIDE Surface mounted 4000 Series LCN closers feature a modern design engineered for each application, easy installation, and superior performance. This guide is based on

More information

7100 Series. Heavy Duty Architectural Door Control

7100 Series. Heavy Duty Architectural Door Control 7100 Series Heavy Duty Architectural Door Control 7100 SERIES HEAVY DUTY ARCHITECTURAL STYLE DOOR CONTROL SUGGESTED ARCHITECTURAL SPECIFICATIONS All door closers shall be American Eagle 7100 Series with

More information

4310ME Series. Features E25. Special Templates. Certifications. Cover Fasteners Mounting Arms

4310ME Series. Features E25. Special Templates. Certifications. Cover Fasteners Mounting Arms 4310ME Features The 4310ME SENTRONIC is a heavy duty, electrically controlled closer/holder designed to provide infinitely adjustable hold-open for fire and smoke barrier doors. Door is held open until

More information

3100 Series. Commercial Door Control

3100 Series. Commercial Door Control 3100 Series Commercial Door Control 3100 SERIES COMMERCIAL Door Control SUGGESTED ARCHITECTURAL SPECIFICATIONS All door closers shall be American Eagle 3100 Series with full rack and pinion construction,

More information

KEANE MONROE a member of the record group

KEANE MONROE a member of the record group SERIES 3000 / 3100 MICROPROCESSOR CONTROL REGULAR ARM SLIDE ARM / SLIDE ARM W/PANIC BREAKAWAY SERIES 3000 / 3100 Page 1. INDEX and OPERATOR HANDING The KM Series 3000/3100 operators have been carefully

More information

5200 Series

5200 Series 5200 Series 5200 Series Closers are engineered and designed to offer the ideal combination of appearance and reliability. The 5200 Series Closers are constructed of aluminum alloy to be installed on exterior

More information

General Information 351 Series Powerglide

General Information 351 Series Powerglide General Information Closer Spring Adjustment (not shown) Effects the entire cycle of the door closer movement Used to size closer for application requirements Determines the amount of force with which

More information

Door Controls DOOR CLOSERS

Door Controls DOOR CLOSERS Door Controls Hager door closers offer architects, contractors, and building owners a superior product with proven reliability. In fact, our 5100, 5200, and 5300 Series Grade 1 models are the only closers

More information

Concealed overhead closer for high-end applications DOOR CLOSERS CATALOG

Concealed overhead closer for high-end applications DOOR CLOSERS CATALOG Concealed overhead closer for high-end applications 7900 S E R I E S DOOR CLOSERS CATALOG INTRODUCTION The 7900 Series Overhead Concealed Closers offer extremely durable operation with the vandal resistance

More information

4040XPT Series Door controls

4040XPT Series Door controls 4040XPT Series Door controls Fire Rated: Tested on fire door assemblies in accordance with Australian Standards, refer fire door manufacturer for specific approval details The LCN 4040XPT Series is a non-handed,

More information

3100 Series. Commercial Door Control

3100 Series. Commercial Door Control 3100 Series Commercial Door Control 3100 SERIES COMMERCIAL DOOR CONTROL SUGGESTED ARCHITECTURAL SPECIFICATIONS All door closers shall be American Eagle 3100 Series with full rack and pinion construction,

More information

* * E996L Series. E996L for Rim/Vertical. E996L for Mortise CAUTION

* * E996L Series. E996L for Rim/Vertical. E996L for Mortise CAUTION *921297-00* 921297-00 Electric Locking Trim E996L Series Installation Instructions CAUTION Product is shipped in Fail Safe (FS) configuration. Fail Safe configuration is required by code in some applications

More information

Floating Headers - 4-1/8, 4-1/2, 6. with RTS88 and PT21 for double doors ONLY. Installation instructions

Floating Headers - 4-1/8, 4-1/2, 6. with RTS88 and PT21 for double doors ONLY. Installation instructions - 4-1/8, 4-1/2, 6 with RTS88 and PT21 for double doors ONLY Installation instructions 933842 EN Table of Contents Table of contents 1 Technical specifications 3 1.1 Overview 3 1.1.1 General information

More information

Norton ABS-AMERICAN BUILDING SUPPLY, INC Series Multi-Sized Closers - Packed 6 per case

Norton ABS-AMERICAN BUILDING SUPPLY, INC Series Multi-Sized Closers - Packed 6 per case ABS-AMERICAN BUILDING SUPPLY, INC. 1601 Series Multi-Sized Closers - Packed 6 per case Features Two Power Ranges: Each series can be adjusted through a range of sizes: Series 1601 Normal Power Range Closers,sizes

More information

7100 Series. Heavy Duty Architectural Door Control

7100 Series. Heavy Duty Architectural Door Control 7100 Series Heavy Duty Architectural Door Control 7100 SERIES Heavy Duty Architectural Door Control SUGGESTED ARCHITECTURAL SPECIFICATIONS All door closers shall be PDQ Industries, Inc. 7100 Series with

More information

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m) Installation Instructions D24-53 Issue Date November 4, 23 D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m) Installation IMPORTANT: The D24-53 Series actuator is intended to control

More information

Installation Instructions CAUTION

Installation Instructions CAUTION Installation Instructions CAUTION An incorrectly installed or improperly adjusted door closer can cause property damage or personal injury. These instructions should be followed to avoid the possibility

More information

TOYOTA RAV4/HV INTERIOR LIGHT KIT Preparation

TOYOTA RAV4/HV INTERIOR LIGHT KIT Preparation Preparation Part Number: PT413-42130 Kit Contents Item # Quantity Reqd. Description 1 1 Wire Harness 2 3 Hardware Bag Contents Item # Quantity Reqd. Description 1 20 Cable Tie 2 2 Scotchlok 3 2 Foam Pad

More information

Surface Applied Door Closers

Surface Applied Door Closers 7300 Surface Applied Door s 7300 SURFACE APPLIED DOOR CLOSERS 7300 SERIES SURFACE CLOSERS 7300 Series with AR Arm 7300 Series with A08 Arm CONTENTS Technical Details and Specifications 4 How to Order 5

More information

Connected To Control Box Series. Closer. Set Screw. Arm Screw. Right Hand Shown. 1/8" I.D. Air Inlet Tubing Connected To Control Box

Connected To Control Box Series. Closer. Set Screw. Arm Screw. Right Hand Shown. 1/8 I.D. Air Inlet Tubing Connected To Control Box *19963* 19963 Auto-Equalizer Low Energy Door Operator 1/8" I.D. Air Inlet Tubing Connected To Control Box Closer 2610 Series Set Screw Arm Screw Track Roller Track Installation Instructions Top Of Door

More information

INSTALLATION EML375. Pre-Installation Instructions. Electromagnetic Locks

INSTALLATION EML375. Pre-Installation Instructions. Electromagnetic Locks INSTALLATION EML375 Electromagnetic Locks Pre-Installation Instructions PLEASE DELIVER ALL INSTALLATION INSTRUCTIONS TO THE END-USER UPON COMPLETION OF THE INSTALLATION. 1. This product must be installed

More information

4040XP Series Door controls

4040XP Series Door controls 4040XP Series Door controls Fire Rated: Tested on fire door assemblies in accordance with Australian Standards, refer fire door manufacturer for specific approval details The LCN 4040XP Series is a non-handed

More information

The 4040XP is LCN s most durable and flexible heavy duty closer designed for institutional and other demanding high traffic applications.

The 4040XP is LCN s most durable and flexible heavy duty closer designed for institutional and other demanding high traffic applications. Features The 4040XP is LCN s most durable and flexible heavy duty closer designed for institutional and other demanding high traffic applications. Certifications Body Construction Fluid Handing Grade 1

More information

*HINGE (pull) side mount shown COVER ACCESSIBILITY NON-HANDED NON-SIZED AVB**

*HINGE (pull) side mount shown COVER ACCESSIBILITY NON-HANDED NON-SIZED AVB** CLOSER MOUNTS *HINGE (PULL) SIDE TOP JAMB (PUSH SIDE) PARALLEL ARM (PUSH SIDE) 4040XP SERIES The 4040XP is LCN s most durable and flexible heavy duty closer designed for institutional and other demanding

More information

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

M9106-AGx-2N0x Series Electric Non-spring Return Actuators Installation Instructions M9106AGx-2N0x Issue Date 08/31/01 M9106-AGx-2N0x Series Electric Non-spring Return Actuators Installation IMPORTANT: The M9106-AGx-2N0x Series actuator is intended to control

More information

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators Installation Instructions M9206-Bxx-2S Issue Date May 14, 2003 M9206-Bxx-2S Series On/Off Electric Spring Return Actuators Installation IMPORTANT: Use this M9206-Bxx-2S Series actuator to control equipment

More information