Install a module ME or MT

Size: px
Start display at page:

Download "Install a module ME or MT"

Transcription

1 Install a module ME or MT Build a converter with a Booster module. ME modules deliver unbalanced three-phase voltages, sufficient for machines with threephase motors. MT produces balanced three-phase voltages for VFDs, welders, plasma cutters, inverter based machines (CC, air conditioning, heat pumps) and for motors running under extreme loads. To build such a converter based on a Booster module, a standard three-phase motor is required. For locations where two-phase is not available, a single -phase auto transformer is needed to convert 240V or 480V into single -phase. Simple connections will combine these three items into one converter. Let an electrician make the connections if you are not the electrical expert yourself. Position these items: Smaller versions: Mount the enclosed transformer and the module side by side on a wall, the motor in a safe box. Larger versions: Install the module on a wall, transformer and idler motor inside a safe box. Or all items in one box. The transformer's kva rating should be 0-5% above the converter's kw rating. Transformer manufacturers may put labels on transformer terminals which are often wrong for three-phase converters. This common labeling is shown in brackets. For a step-up transformer in a converter, must to be connected to the center tap and L to the common tap. Test: Measure about 75V between the third connector and eutral. Measure across Common and the opposite connector. Any voltage between a transformer output and eutral must not be higher than the input voltage. for standard 240V single phase supply: (45) 75V to (L) eutral 240V L () 240V to (0) eutral Labeling shown above in brackets is often found with standard transformers. They are wrong for use in converters. Change labels. Test voltages first before you connect a transformer to a module. Make sure phase of a converter is always 240V to eutral. Rural 480V split phase supply: La 480V 75V to eutral Lb 240V to eutral

2 Use 240V 75V to to eutral step-up transformer for a standard 240V single 240V to phase eutral supply L 240V Single phase input Module ME MT 2 2 three-phase output to machines Use 480V to step-down transformer for a standard 480V split-phase supply La 75V to eutral La Lb 480V Single phase input The correct supply voltage to a module M is + - 0%. o transformer is required when the supply is (two phases from a three-phase supply). The output of a module M must be connected to a 2-pole three-phase idler motor (large soft-start modules require two identical motors). This motor must be in configuration (almost all motors for 50Hz above kw are when set to ), the kw rating must be as specified for a module. Make sure the motor is connected for. ever use a motor other than specified here. A module ME can be used without an idler motor but only if the load motor is exactly as the idler motor. Such a motor will only produce about 75% maximum torque and power. We recommend to always use an idler motor. A module MT always requires an idler motor to work. The idler motor supports phase voltage balancing and correct phase angle separation. Direction of the rotation can be left or right. Three-phase voltages are only present when a motor is running. Control transformers and single-phase loads: A eutral wire is only required if a control transformer or a single-phase load inside a machine is connected between one of the phases and eutral (240V). Find out by measuring the resistance of a control transformer on a disconnected machine's plug (when the main switch is in On position). If eutral is needed, feed a eutral wire through a converter to the output. For single-phase loads or control transformers inside a machine, only use L to eutral. The voltages between phase or 2 to eutral are not 240V. If a motor in a machine rotates in the wrong direction: swap phases and 2. A control transformer or a single-phase load inside a machine is : identify the two phases where the control transformer or load is connected to by measuring the coil resistance on a machine's plug (main switch in On position). Connect the two phases for such a single-phase load to converter output and only. If a motor in a machine rotates in the wrong direction: swap phases and only. Start installation: Drill holes for glands into the bottom side of the module. See the drill guides in box.

3 Install: - the module onto a wall. Use the wall brackets supplied. Protect from water and heat. - a slow motor-rated or D-curved circuit breaker in the house's fuse box, see values below. - a dual circuit breaker for disconnecting both phases if supply is two- phase or 480V. - an industrial single phase (240V) or two-phase (480V) wall switch. - three-phase wall outlets or a distribution panel near the machines. - the idler motor on soft rubber mounts (Embleton, Mackay, Skellerup or others). Connect the three output phases of a module to the idler motor connector: > left, 2 > centre, > right or, if vertical, from top to bottom. This is for easier service should phone support be needed. Connect: - Protective Earth () to the transformer, to the module (T), to the pilot motor, to the power outlets and to the machines. - Single-phase supply to a protective circuit breaker inside the house fuse box, then to a wall switch, then to the transformer and to the module. - Module output 2 to the idler motor and to the machines. Large modules require a second motor. Supply Fuse Transformer ME4 MT4 240V 20A 4.5kVA 240 to.7kw (5hp) ME8 MT8 240V 40A 9kVA 240 to 7.5kW (0hp) MT8 480V 2x 20A - MT2 480V 2x 0A 4kVA 480 to kw (5hp) MT2 240V 60A 4kVA 240 to kw (5hp) MT6 480V 2x 40A 9kVA 480V to 5kW (20hp) MT6 240V 80A 9kVA 240V to 5kW (20hp) MT24 480V 2x 60A 27kVA 480V to 2x kw (5hp) MT24 240V 20A 27kVA 240V to 2x kw (5hp) Test: Test transformer first for correct output voltages. Connect to module. Connect to idler motor(s). Apply power. motor starts fast and runs quietly. Test voltage phase to eutral = 240V. Test voltages between phases for +- 0% when the idler motor is running. Connect machines after voltages found to be correct and connections of machine's control transformers are correct. Should a motor rotation be wrong: swap two phases to the machine, see under control transformers. Welders: Transformer-type welders often require only two of the three phases. Connect these phases to converter output L and L. Inverter type welders: find any control transformer connection (if present) as with machines (measure control transformer resistance on welder's plug). If resistance is found to be symmetrical. Connect as you like. Some machines have a phase sequence relay and only work if the phase sequence is correct. Danger: Do not run a module when open. Capacitors are charged with high voltages. Voltages are slowly discharged and remain dangerous for some minutes. Open a module: Disconnect from power. Wait for at least ten minutes until internal capacitors are fully discharged. Measure first if all capacitors and connectors have a safe voltage before doing any work.

4 In Out Left: Transformer, module, motor installed seperately Right: Transformer and motor in a box. Module on a wall. Below: Transformer, motor and module in one box.

5 A special application: The three-phase load is not one or several three-phase motors but an inverter (VFD, CC, welder, plasma cutter, air conditioning). Add a second idler motor, same specification as the first one. This can be done by a manual switch. Start converter, then start motor 2, then start load. Or use a contactor and a delay circuit. Set delay to two seconds. 2 will start two seconds after motor. Start load when both motors are running. Module ME MT Manual 2 In 2 Out Manual switch Module ME MT Automatic 2 In 2 Out 2A contactor A2 A 240V coil 8 5 A A2 Merlin Gerlin Multi 9 RTA timer set to 2 sec on-delay

6

Electric Motor Controls BOMA Pre-Quiz

Electric Motor Controls BOMA Pre-Quiz Electric Motor Controls BOMA Pre-Quiz Name: 1. How does a U.P.S. (uninterruptable power supply) work? A. AC rectified to DC batteries then inverted to AC B. Batteries generate DC power C. Generator, batteries,

More information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5 3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V

More information

Easy Start. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual

Easy Start. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual Easy Start 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter Installation Manual Micro Air Corporation Phone (609) 259-2636 124 Route 526. www.microair.net Allentown NJ 08501 Fax (609) 259-6601 Retrofit

More information

HYDRUS INSTALLATION INSTRUCTION P/N: 3801-EOP AUTO REVERSE / AUTO STOP OPTION KIT FOR HYDRUS 2000 MAIN PANEL

HYDRUS INSTALLATION INSTRUCTION P/N: 3801-EOP AUTO REVERSE / AUTO STOP OPTION KIT FOR HYDRUS 2000 MAIN PANEL HYDRUS INSTALLATION INSTRUCTION P/N: 3801-EOP AUTO REVERSE / AUTO STOP OPTION KIT FOR HYDRUS 2000 MAIN PANEL BILL OF MATERIALS: (1) P/N: 4372 - LATCHING RELAY, (1) P/N: 5322 RELAY SOCKET, (4) P/N: 3700-74

More information

Vigilec doble. Pump controlller and protection for two (3ph/1ph) pumps INSTALLATION AND OPERATION

Vigilec doble. Pump controlller and protection for two (3ph/1ph) pumps INSTALLATION AND OPERATION V2P/V2T Vigilec doble INSTALLATION AND OPERATION V2P V2T Pump controlller and protection for two (3ph/1ph) pumps (V2P: control by pressure switches/ V2T: control by pressure transducer) General Description

More information

Components for EEx e Panels

Components for EEx e Panels Circuit Interrupters / Motor Switches 8006/3 8543/1 8543/2 8548/2 40 A 63 A 80 A 1 160 A 500 V 660 V 500 V 01766E00 No. of poles 12 poles Isolator features Switching capacity 400 V, AC3 11 kw 22 kw 37

More information

Bolted contact switches. Pringle switches

Bolted contact switches. Pringle switches Bolted contact switches Pringle switches Eaton s Pringle bolted contact switches History Eaton s PringleT switches have helped pioneer the development of high-quality electrical products for commercial

More information

KENYA POWER-MOMBASA BRANCH REPLACEMENT OF AIR-CONDITIONING AND ASSOCIATED WORKS BILLS OF QUANTITIES FOR ELECTRICAL INSTALLATIONS BILL NO

KENYA POWER-MOMBASA BRANCH REPLACEMENT OF AIR-CONDITIONING AND ASSOCIATED WORKS BILLS OF QUANTITIES FOR ELECTRICAL INSTALLATIONS BILL NO BILL 1 MAINS POWER DISTRIBUTION 2-1 ITEM DESCRIPTION QTY UNIT RATE AMOUNT Supply, install, test, commission and set to work the following:- 1.01 Free-standing purpose made front access sub main switchboard

More information

Pump ED 101. Power Factor (Part 2) - - Electricity Behaving Better

Pump ED 101. Power Factor (Part 2) - - Electricity Behaving Better Pump ED 101 Power Factor (Part 2) - - Electricity Behaving Better Joe Evans, Ph.D http://www.pumped101.com Last month we took a close look at the flow of voltage and current in purely resistive and inductive

More information

Power Systems Trainer

Power Systems Trainer Electrical Power Systems PSS A self-contained unit that simulates all parts of electrical power systems and their protection, from generation to utilisation Key Features Simulates generation, transmission,

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION 0 F LOW AMBIENT ACCESSORY MODELS 2LA04703425, 3546 & 3658 (208, 230, 460 & 575 VOLT APPLICATIONS) Supersedes: 530.18-N5.6V (1091) 530.18-N5.6V (1193) FOR 15, 20 & 25 TON COOLING

More information

Variable Transformers Series to Amperes

Variable Transformers Series to Amperes Variable Transformers Series 6000 35.0 to 315.0 Amperes ISE, Inc. - 10100 Royalton Rd. - Cleveland, OH 44133 USA - Tel: (440) 237-3200 - Fax: (440) 237-1744 - http://instserv.com 5000/6000 Series Manual,

More information

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos: PHASE CONVERTERS MODEL NO: PC40 and PC60 MODEL PART No: NO: 6012805 PC20 and PC40 6012810 PC60 PART Nos: 6012800 6012805 6012810 OPERATING & MAINTENANCE INSTRUCTIONS 0107 Specifications PC20 PC40 PC60

More information

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany File E47705 Project 97ME18400 August 21, 1997 REPORT on MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany Copyright 1997 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above

More information

Installation and Construction Notes for EVSE4

Installation and Construction Notes for EVSE4 Installation and Construction Notes for EVSE4 You need to read and understand this if you want to build an EVSE that will be safe and need to pass a building inspectors review. Before beginning this process

More information

MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM

MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM _ M MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM User's MANUAL Code: MVM Version: 01-BF Date: OCT 2005 Page 1/10 _ 1. INTRODUCTION Before starting to use your Energic plus MVM battery charger, please take

More information

ADS7 AC Contactor Starters

ADS7 AC Contactor Starters ADS7 AC Contactor Starters ADS7 starters fully comply with BS EN 60947-4-1, IEC 60947-4-1 and VDE 0660. The range offers a multitude of configurations and optional features including a complete choice

More information

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised: File E47705 Vol. 7 Sec. 9 Page 1 Issued: 1997-08-29 and Report Revised: 2005-06-30 DESCRIPTION PRODUCT COVERED: USL, CNL - Type Nos. 3RV1021, 3RV1121, 3RV1321 or 3RV1421, followed by combination of 0,

More information

SINGLE-PHASE PUMP START AND PROTECTION BOX Type V1M, V1N, V1E, V1F

SINGLE-PHASE PUMP START AND PROTECTION BOX Type V1M, V1N, V1E, V1F www.motor-pump-ventilation.com SINGLE-PHASE PUMP START AND PROTECTION BOX Type V1M, V1N, V1E, V1F Owner s manual Main features An all-in-one control and protection unit for any pump. Multicontrol. Vigilec

More information

3 Phase Voltage Imbalance

3 Phase Voltage Imbalance 3 Phase Voltage Imbalance Keep in mind when reading ANY article about electrical theory or application is that it only scratches the surface of the topic. You can dedicate years of your life to understanding

More information

LG HRC Power Fuses ISO 9001 ISO 14001

LG HRC Power Fuses ISO 9001 ISO 14001 LG HRC Power Fuses ISO 900 ISO Current without Power Fuse (ka ms) Ipeak Let through Below 0.5 Cycle voltage(kv) Initiation of 3. 7. 5.5 3 arcing(degree) Ipeak(kA) Power Factor 5 5 90 5 70 9 0 7 7 7 5 5

More information

Hitachi America, Ltd.

Hitachi America, Ltd. Hitachi America, Ltd. RCU Series Regenerative Converter Unit Instruction Manual NOTE: REFER ALSO TO APPLICABLE INVERTER INSTRUCTION MANUAL Manual Number: HAL1057A May 2010 After reading this manual, keep

More information

SMC BATTERY CHARGER USER S MANUAL SMC USER S MANUAL

SMC BATTERY CHARGER USER S MANUAL SMC USER S MANUAL SMC BATTERY CHARGER SMC 1 INDEX 1 INDEX... 1 2 INTRODUCTION... 2 2.1 INTRODUCTION AND REFERENCES... 2 2.2 GLOSSARY... 2 2.3 DATA LABEL... 2 2.4 HOW TO USE THE USER'S MANUAL... 2 2.5 RESPONSIBILITY DISCLAIMER...

More information

OPERATION INSTRUCTIONS

OPERATION INSTRUCTIONS www.r-techwelding.co.uk Tel: 01452 733933 Fax 01452 733939 PLASMA 50HF INVERTER PLASMA CUTTER OPERATION INSTRUCTIONS Version 2014-1 2 Thank you for selecting the R-Tech PLASMA 50HF Inverter Plasma Cutter

More information

IES GRID FEED-IN LIMITER

IES GRID FEED-IN LIMITER IES GRID FEED-IN LIMITER Installation and User Manual Models SPS01101-ABB SPS01303-ABB CONTAINS IMPORTANT INSTALLATION AND TESTING PROCEDURES THAT MUST BE FOLLOWED TO ENSURE COMPLIANCE WITH ENERGEX AND

More information

Application Engineering

Application Engineering Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

SOLSTART Instruction Manual

SOLSTART Instruction Manual Solstart Analog Soft Starter 8-58A, 220-600V Instruction Manual Ver. 23/03/2009 2 Table of Content SOLSTART Instruction Manual 1. TABLE OF CONTENT 1. Table of Content...2 2. Safety & Warnings...3 2.1 Safety...3

More information

HIB Enclosed Inverter User Guide

HIB Enclosed Inverter User Guide HIB Enclosed Inverter User Guide (0.75kW~22kW) V1.2.0 Contents 1 Safety information...1 2 Technical Data...2 3 Motor Connection...4 4 Operation...5 5 Single phase circuit diagram...7 6 Three phase circuit

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

Chest Heated Ironer Refer to Page 3 for Model Numbers

Chest Heated Ironer Refer to Page 3 for Model Numbers Chest Heated Ironer Refer to Page 3 for Model Numbers Parts www.comlaundry.com Part No. 1800144R1 February 2008 Table of Contents Title Page Parts Ordering Information... 2 Nameplate Location... 2 Model

More information

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation MATRIX FILTER SERIES D 600 Volts, 60HZ USER MANUAL PART NO. INSTR 026 REL. 080920 2008 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter is designed for harmonic mitigation

More information

Benefits of VFD for single to three phase conversion

Benefits of VFD for single to three phase conversion Benefits of VFD for single to three phase conversion Agenda Differences between three phase and single phase power & effects on devices they power What is a VFD and how does it work when used for phase

More information

Yaskawa Electric America Unit Troubleshooting Manual Section One: Introduction & Checks Without Power GPD 506/P5 and GPD 515/G5 (0.

Yaskawa Electric America Unit Troubleshooting Manual Section One: Introduction & Checks Without Power GPD 506/P5 and GPD 515/G5 (0. Yaskawa Electric America Unit Troubleshooting Manual Section One: Introduction & Checks Without Power GPD 506/P5 and GPD 515/G5 (0.4 ~ 160kW) Page 1 Introduction This manual is divided into three sections:

More information

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. Quick Reference ❶ Performance Data Pages

More information

OpenEV. OpenEVSE 40A Charging Station. Build a Charging station for a 50A circuit (40A Charge current) with an OpenEVSE kit.

OpenEV. OpenEVSE 40A Charging Station. Build a Charging station for a 50A circuit (40A Charge current) with an OpenEVSE kit. OpenEV OpenEVSE 40A Charging Station Build a Charging station for a 50A circuit (40A Charge current) with an OpenEVSE kit. Written By: Christopher Howell 2017 openevse.dozuki.com/ Page 1 of 13 INTRODUCTION

More information

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation M T E C o r p o r a t i o n MATRIX FILTER SERIES B 380-415 Volts, 50HZ USER MANUAL PART NO. INSTR - 015 REL. 060628 2006 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter

More information

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR CLASSIFICATION. 2010, The McGraw-Hill Companies, Inc.

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR CLASSIFICATION. 2010, The McGraw-Hill Companies, Inc. Chapter 2 MOTOR CLASSIFICATION 1 In general, motors are classified according to the type of power used (AC or DC) and the motor's principle of operation. AC DC Motor Family Tree 2 DC MOTOR CONNECTIONS

More information

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com

More information

PARTS LIST, COUNTER CONVECTION STEAMERS MODELS SN-3E, SN-4E, SN-5E PARTS LIST COUNTER CONVECTION STEAMERS BLODGETT MODELS: SN-3E SN-4E

PARTS LIST, COUNTER CONVECTION STEAMERS MODELS SN-3E, SN-4E, SN-5E PARTS LIST COUNTER CONVECTION STEAMERS BLODGETT MODELS: SN-3E SN-4E PARTS LIST COUNTER CONVECTION STEAMERS BLODGETT MODELS: SN-3E SN-4E November 27, 2013 BLODGETT OVEN CO 44 lakeside Ave Burlington, VT 05446 Tel. 802-658-6600 Fax 802-860-3732 www.blodgett.com 1 2013-11-27

More information

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL FORM: MX-TRM-E REL. September 2014 REV. 002 2014 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation

More information

Type SOQ Negative Sequence Time Overcurrent Relay

Type SOQ Negative Sequence Time Overcurrent Relay ABB Power T&D Company Inc. Power Automation & Protection Division Coral Springs, FL Allentown, PA April 1998 Supersedes DB dated August 1991 Mailed to: E,D, C/41-100B For Protection of Rotating Machinery

More information

* With I-Option card only (C. T. connection) Basic connections with isolated contacts

* With I-Option card only (C. T. connection) Basic connections with isolated contacts Typical Circuit Diagrams. Typical Circuit Diagrams Basic connections with isolated contacts F2 - Overload relay Q1 - MPCB / ACB / MCCB /K2 - Main isolating contactors (AC-3 rated) F3 - Semiconductor Fuses

More information

ELECTRIC HEAT ACCESSORY INSTALLATION INSTRUCTION. 20, 30 & 40 kw for 15 Ton Split System Air Conditioners Models: LB180 & LL A-0102

ELECTRIC HEAT ACCESSORY INSTALLATION INSTRUCTION. 20, 30 & 40 kw for 15 Ton Split System Air Conditioners Models: LB180 & LL A-0102 INSTALLATION INSTRUCTION ELECTRIC HEAT ACCESSORY 20, 30 & 40 kw for 15 Ton Split System Air Conditioners Models: LB180 & LL-15 CONTENTS GENERAL...2 NOTES, CAUTIONS AND WARNINGS........... 2 REFERENCE...2

More information

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description

More information

MMA 160S ARC/MMA WELDER OPERATION INSTRUCTIONS

MMA 160S ARC/MMA WELDER OPERATION INSTRUCTIONS www.r-techwelding.co.uk MMA 160S ARC/MMA WELDER OPERATION INSTRUCTIONS 2 Thank you for selecting the R-Tech MMA160S Inverter Arc Welder. The MMA160S has many benefits over traditional Arc welders, including

More information

ELECTRICAL INSTALLER THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET

ELECTRICAL INSTALLER THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET Candidate Code No. EIN 08 For Board Use Only Result Date Int Result Date Int ELECTRICAL INSTALLER THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ CAREFULLY Time Allowed: Three

More information

Quick Start Guide TS 910

Quick Start Guide TS 910 Quick Start Guide TS 910 DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer is responsible

More information

M.V. LIMITING FUSE WITH THERMAL PROTECTION

M.V. LIMITING FUSE WITH THERMAL PROTECTION M.V. LIMITING FUSE WITH THERMAL PROTECTION 1 INDEX 1.- Why Limiting Fuses? 2.- When does those situations happen? 3.- Market Solutions 4.- MERLIN GERIN Thermal Protection 5.- Technical, economical and

More information

SUSSMAN 'ES, HU and MBA' SERIES PARTS LIST EFFECTIVE: 7/24/2017

SUSSMAN 'ES, HU and MBA' SERIES PARTS LIST EFFECTIVE: 7/24/2017 EFFECTIVE: 7/24/2017 STEAM SAFETY VALVES 99136 100 PSIG 1/2" NPT (ES12 to ES72) 99137 100 PSIG 1" NPT (ES84 to ES180) 99132 15 PSIG 1/2" NPT (ES12 to ES48, HU40 to HU140) 99297V 15 PSIG 3/4" NPT (ES60

More information

(337) FAX

(337) FAX SECONDCIRCUITS.COM FASTEST LEAD TIMES ON CUSTOM PANELS 1-2 week delivery normal 1 DAY SHIP AVAILABLE UL508A SHOP 1-888-463-2759 (337)785-9343 FAX SALES@SECONDCIRCUITS.COM TABLE OF CONTENTS About Us 3 Rentals

More information

Application Engineering

Application Engineering Application Engineering March 2011 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital compressor or the

More information

- all rights reserved

- all rights reserved 53H New SILVER 15/20 8-10-13 Bar - 50/60 Hz 1/4 20171205 F00598/F00598:901826-1- NEW SILVER 15-20 1/4 1 1125160743 Compressor foot 2 2 1125160930 Base 1 3 1126000015 Joint 1 4 1127010109 Screw 8 5 1127010116

More information

Open Chassis Star-Delta Starter User Guide

Open Chassis Star-Delta Starter User Guide Open Chassis Star-Delta Starter User Guide (7.5kW~90kW) V2.0.1 Contents 1 Safety information... 1 2 Technical Data... 2 3 Supply & Motor Connections & Circuit Diagrams... 5 4 Control Connections & Operation...

More information

CI-TI Contactors and Motor Starters Type CI 6-50

CI-TI Contactors and Motor Starters Type CI 6-50 Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components

More information

Adjustable Pneumatic Time Delay Switch

Adjustable Pneumatic Time Delay Switch Adjustable Pneumatic Time Delay Switch Model: DS4 Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further reference and maintenance.

More information

ICG Switchgear Price List 2009

ICG Switchgear Price List 2009 ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section

More information

SDS Enclosed Star-Delta Starter User Guide

SDS Enclosed Star-Delta Starter User Guide SDS Enclosed Star-Delta Starter User Guide (7.5kW~90kW) V2.0.0 PLEASE NOTE: AS STANDARD AND UNLESS OTHERWISE SPECIFIED, THIS PRODUCT IS EQUIPPED WITH A BASIC LOW INTEGRITY EMERGENCY STOP CIRCUIT STOPPING

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

BATTERY CHARGER-STARTER

BATTERY CHARGER-STARTER BATTERY CHARGER-STARTER MODEL NO: WBC240 & WBC400 PART NO: 6261505 & 6261515 OPERATION & MAINTENANCE INSTRUCTIONS GC0116 INTRODUCTION Thank you for purchasing this CLARKE Battery Charger/Starter. Please

More information

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH 331-SV User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER Ashland, OH 800-363-5842 WWW.PRIMEXCONTROLS.COM Warranty void if panel is modified. Call factory with servicing

More information

Brake Chopper BC BC 4.1. Instruction and Operation Manual

Brake Chopper BC BC 4.1. Instruction and Operation Manual Brake Chopper BC 2.1 - BC 4.1 Instruction and Operation Manual Caution: There is always a risk involved in the handling of electrical machinery! Therefore mounting and maintenance should only be done by

More information

ATTIX 170. Part List US-English. Model: ATTIX 170

ATTIX 170. Part List US-English. Model: ATTIX 170 Model: Part List US-English Table of Contents Lmh atex label 3 Frame 1 5 Frame 2 7 Frame 3 9 Container unit 11 Filter group 13 Manual shaker unit 15 Electrical shaker unit - 1 17 Electrical shaker unit

More information

Control Box Wiring For PRSstandard Tool

Control Box Wiring For PRSstandard Tool 888-680-4466 ShopBotTools.com Control Box Wiring For PRSstandard Tool Copyright 2017 ShopBot Tools, Inc. page 1 Copyright 2017 ShopBot Tools, Inc. page 2 Table of Contents Introduction...5 Installation...5

More information

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012 SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive

More information

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor unit ASYA24LCC ASYA24LCC ASYA24LCC Outdoor unit AOYR24LCC AOYR24LCD AOYR24LCL CONTENTS SPECIFICATIONS..................1 DIMENSIONS.....................

More information

Synergy EN product information

Synergy EN product information Synergy EN60947-4-2 product information Rated operational voltages U e 200Vac to 480Vac Rated operational currents I e See Rating Table Rating index See Sizing Guide Rated frequency/frequencies 50-60Hz

More information

Instruction Manual. Q Series 2 Motor Control Modules - OEM

Instruction Manual. Q Series 2 Motor Control Modules - OEM A382-21-880 Issue B Instruction Manual Q Series 2 Motor Control Modules - OEM Pump/ Q Motor Control Module Item Number pumping system Electrical supply 24 V d.c. control 24 V a.c. control QDP40 200-230

More information

THREE-POLE CONTACTORS series HR09-HR13 up to 6 kw

THREE-POLE CONTACTORS series HR09-HR13 up to 6 kw THREE-POLE CONTACTORS series HR09-HR3 up 6 kw USE Series HR contacrs are particularly suitable for controlling mors, heating elements and three-phase and single-phase loads in general. OPERATION AND INSTALLATION

More information

CI-TI Contactors - VLT Frequency Converters

CI-TI Contactors - VLT Frequency Converters MN.90.K1.02 - VLT is a registered Danfoss trademark 1 Description This data sheet is based on tests made in co-operation with Contactor Business from Danfoss Automatic Division and Danfoss Drives A/S.

More information

PLASMA CUTTER OWNER`S MANUAL MODEL : CUT 40/60. (POWER v-mos CONTROLIED, PLASMA CUTTING POWER SUPPLY)

PLASMA CUTTER OWNER`S MANUAL MODEL : CUT 40/60. (POWER v-mos CONTROLIED, PLASMA CUTTING POWER SUPPLY) PLASMA CUTTER OWNER`S MANUAL MODEL : CUT 40/60 (POWER v-mos CONTROLIED, PLASMA CUTTING POWER SUPPLY) PRODUCTS INTRODUCTION Congratulations for your purchase. CUT 40,CUT 60 are made by international most

More information

MCC Automatic Start-Stop Microcomputer Charger Control

MCC Automatic Start-Stop Microcomputer Charger Control MCC Automatic Start-Stop Microcomputer Charger Control Installation & Operation Instructions Warning: Read ALL the instructions before starting. If anything is not clear, call your dealer or contact Arrgh!!

More information

Trouble Shooting Guide EWA, 3-phase (D2422)

Trouble Shooting Guide EWA, 3-phase (D2422) Trouble Shooting Guide EWA, 3-phase (D2422) Trouble Shooting Guide Problem Possible Cause Possible Remedy Unit does not start Breaker tripped, no power to unit Loose wire Defective contactor or coil Close

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

ALL PURPOSE CNC/HEAVY DUTY

ALL PURPOSE CNC/HEAVY DUTY ALL PURPOSE CNC/HEAVY DUTY Rotary Phase Converters 240 & 480 VOLT SERIES Rotary Phase Con verter Operation & Installation Manual MTPC-RB-208.240-1P-10HP-3P DANGER: HIGH VOLTAGE Electric shock could result

More information

Control panel. For 3 three-phase electric pumps with thermal protection and exchanger

Control panel. For 3 three-phase electric pumps with thermal protection and exchanger AUTOCLAVES PRODUCTS Control panel For 3 three-phase electric pumps with thermal protection and exchanger General features: Electromechanic panel with electronic control Sequence exchanger for 2 electro

More information

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation M T E C o r p o r a t i o n MATRIX FILTER SERIES B 380-415 Volts, 50HZ USER MANUAL PART NO. INSTR - 015 REL. 040709 2003 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter

More information

OPERATION INSTRUCTIONS

OPERATION INSTRUCTIONS www.r-techwelding.co.uk Email: sales@r-techwelding.co.uk Tel: 01452 733933 Fax: 01452 733939 ProArc 175 INVERTER ARC WELDER OPERATION INSTRUCTIONS Version 2017-10 2 3 Thank you for selecting the R-Tech

More information

CWM_N NEMA Rated Contactors

CWM_N NEMA Rated Contactors Motors Automation Energy Transmission & Distribution Coatings CWM_N NEMA contactors have been a mainstay in the industrial marketplace in the US for decades. NEMA contactors were known for being robust

More information

A WORD ABOUT PROPER GROUNDING

A WORD ABOUT PROPER GROUNDING A Word About Proper Grounding Section 5-3 A WORD ABOUT PROPER GROUNDING Due to the wet environment of irrigation equipment, it is very important that your Pierce CP600 Center Pivot Irrigation System be

More information

L. Photo. Figure 2: Types CA-16 Relay (rear view) Photo. Figure 1: Types CA-16 Relay (front view)

L. Photo. Figure 2: Types CA-16 Relay (rear view) Photo. Figure 1: Types CA-16 Relay (front view) Figure 1: Types CA-16 Relay (front view) Photo Figure 2: Types CA-16 Relay (rear view) Photo 2 Sub 5 185A419 Sub 6 185A443 Figure 3: Internal Schematic of the Type CA-16 bus Relay or CA-26 Transformer

More information

TABLE OF CONTENTS 1 - GENERAL...3

TABLE OF CONTENTS 1 - GENERAL...3 Instructions for use I TABLE OF CONTENTS Page 1 - GENERAL...3 1.1 - GENERAL SAFETY REGULATIONS...3 1.1.1 - STANDARD SAFETY DEVICES...3 1.2 - FIELD OF APPLICATION...3 1.3 - OVERALL DIMENSIONS...3 1.4- TECHNICAL

More information

ASHRAE - Variable Speed Drives. By Dan Watkins, LEED BD+C Bornquist, Inc.

ASHRAE - Variable Speed Drives. By Dan Watkins, LEED BD+C Bornquist, Inc. ASHRAE - Variable Speed Drives By Dan Watkins, LEED BD+C Bornquist, Inc. Adjustable Frequency Drive Fundamentals How does a VFD actually work VS Pumping Analysis VS Pumping Features Harmonics VFDs and

More information

CSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date:

CSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date: CSDA Best Practice Title: Hi-Cycle Concrete Cutting Equipment Issue No: CSDA-BP-010 : Oct 1, 2010 Revised : Introduction Hi-cycle/high frequency concrete cutting equipment has become more prevalent in

More information

WELLS RURAL ELECTRIC COMPANY Adopted: March 1976 Revised: March 21, 2017 Reviewed: August 21, 1998 RULE NO. 2

WELLS RURAL ELECTRIC COMPANY Adopted: March 1976 Revised: March 21, 2017 Reviewed: August 21, 1998 RULE NO. 2 WELLS RURAL ELECTRIC COMPANY Adopted: March 1976 Revised: March 21, 2017 Reviewed: August 21, 1998 DESCRIPTION OF SERVICE A. General: RULE NO. 2 1. Alternating current service at 60-hertz (cycles per second)

More information

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS A. 11 KV SWITCHGEAR 1.0 SWITCHGEAR ASSEMBLY 1.1 Make : 1.2 Type : 1.3 Reference Standard : 1.4 Voltage (Nom./Max.) KV : 1.5 Phase, Frequency No,Hz.

More information

ALIEM USER MANUAL R. Bocconi. REV. DATE Checked and Approved R. T.

ALIEM USER MANUAL R. Bocconi. REV. DATE Checked and Approved R. T. ALIEM USER MANUAL 2 19-04-2018 R. Bocconi REV. DATE Checked and Approved R. T. PAGE INTENTIONALLY LEFT BLANK 2 ALIEM 1000 USER'S MANUAL Version 2 dated 19-04-2018 1 INTRODUCTION ALIEM 1000 is an emergency

More information

www.ic-electronic.com Soft starter with integrated Motor Protection, Current and Voltage control Single phase controlled with internal by-pass ated operational Voltage 230VAC Frequency 45... 65Hz Self

More information

.2 Section Waste Management and Disposal..5 Section Thermometers and Pressure Gauges Piping Systems.

.2 Section Waste Management and Disposal..5 Section Thermometers and Pressure Gauges Piping Systems. Issued 2005/06/01 Section 15440 Plumbing Pumps Page 1 of 9 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3 Section 01780 Closeout

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

PHASEPERFECT 240V. Digital Phase Converter. Operation & Installation Manual. Single-Phase to Three-Phase Solid State Technology 97% Efficient

PHASEPERFECT 240V. Digital Phase Converter. Operation & Installation Manual. Single-Phase to Three-Phase Solid State Technology 97% Efficient POWER BY DESIGN PHASEPERFECT 240V Digital Phase Converter Operation & Installation Manual Single-Phase to Three-Phase Solid State Technology 97% Efficient SAFETY MESSAGES AND WARNINGS To ensure safe and

More information

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out) TECHNICAL DATA SHEET INFINITY 3300 10 15 20 kva 3Ph(in) 3Ph(out) GENERAL INFORMATION POWER - kva 10 15 20 UPS typology ON LINE Double conversion ACTIVE stand by-operation (Optional) Nominal output power

More information

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL REV MTE Corporation

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL REV MTE Corporation MATRIX FILTER SERIES D 600 Volts, 60HZ USER MANUAL PART NO. INSTR 026 REL. 120628 REV. 007 2012 MTE Corporation Matrix Series D User s Manual 600VAC IMPORTANT USER INFORMATION NOTICE The MTE Corporation

More information

IU0U automatic charger Read these instructions carefully before the installation and commissioning and keep them in a safe place. Pass it on to the buyer in case of the further sale of the system. Contents

More information

MATRIX FILTER USER MANUAL. SERIES D 480 Volts, 60HZ PART NO. INSTR 024 REL REV MTE Corporation

MATRIX FILTER USER MANUAL. SERIES D 480 Volts, 60HZ PART NO. INSTR 024 REL REV MTE Corporation MATRIX FILTER SERIES D 480 Volts, 60HZ USER MANUAL PART NO. INSTR 024 REL. 120628 REV. 012 2012 MTE Corporation Matrix Series D User s Manual 480VAC IMPORTANT USER INFORMATION NOTICE The MTE Corporation

More information

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING Matrix AP 400V 690V INSTALLATION GUIDE FORM: MAP-IG-E REL. May 2017 REV. 002 2017 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.

More information

ENGLISH NO Fan Starter INSTRUCTION MANUAL. Fan Starter 4. 4 kw 400 V 3~(+N) 50 Hz ART. NO

ENGLISH NO Fan Starter INSTRUCTION MANUAL. Fan Starter 4. 4 kw 400 V 3~(+N) 50 Hz ART. NO ENGLISH NO. 148 317 01 2000-03-09 Fan Starter INSTRUCTION MANUAL Fan Starter 4 4 kw 400 V 3~(+N) 50 Hz ART. NO. 512337 List of contents Page CE, Declaration of conformity 3 Safety 4 Technical data 4 Accessories

More information

Source-Side Fuse/Load-Side Recloser Coordination

Source-Side Fuse/Load-Side Recloser Coordination How to Coordinate ransformer Primary-Side Fuses with Feeder Reclosers Using Coordinaide M he S&C Protection and Coordination Assistant Part I: Conservative Method his is the first in a series of articles

More information

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2 DESCRIPTION AND FEATURES... 3 CHARGING STAGES... 4 Art. No. EC-315 Art. No. EC-330 Art. No. EC-340 PROTECTIONS... 5 INSTALLATION...

More information

MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES M450

MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES M450 MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES M450 TABLE OF CONTENTS PART I GENERAL DESCRIPTION... PAGE 2 PART II FUNCTIONS... PAGE 2 PART III INSTALLATION... PAGE 3 PART IV INITIAL INSTALLATION

More information