1 Photographer: BRUCE T. MARTIN, 2011 LFD Laminar Flow Diffuser

2 Typical Applications The LFD s non-aspirating, unidirectional, laminar flow air pattern is ideal for applications where a low velocity and minimal entrainment of room air is required. Applications requiring the use of such diffusers include: hospital operating rooms, cleanrooms, laboratories, and protective isolation rooms. The LFD is classified as an ASHRAE group E non-aspirating diffuser and meets ASHRAE 170 requirements. CONFIGURATION OPTIONS Engineered equalization baffle Easily Removable Face Adjustable Inlet Damper Hybrid Construction One-Piece Welded Plenum 1/2" Foil Backed Insulation Product Highlights Price LFD laminar flow diffusers are engineered to provide a uniform, unidirectional, vertical projection of supply air at a controlled, low velocity. The laminar flow diffuser utilizes an internal engineered equalization baffle, resulting in a dual chamber design that introduces clean supply air to the space with minimal entrainment of room air because of the low, controlled discharge velocity. The Price LFD is available in multiple sizes (including metric), in aluminum, stainless steel, steel, and hybrid construction. Many standard and optional features make the LFD a the most versatile laminar flow diffuser on the market. Engineered Equalization Baffle The integrated equalization baffle provides uniform, unidirectional airflow across the face of the diffuser, preventing entrainment of potentially contaminated room air in the diffuser s airflow. The equalization baffle is easy to remove from the diffuser face for sterilization. Easily Removable Face Laminar Flow Diffuser Quarter turn fasteners and stainless steel retainer cables make the diffuser face easy to remove for quick access to the plenum for cleaning and inlet damper adjustment. Adjustable Inlet Damper The optional butterfly-style inlet air damper allows for air balancing and fine tuning ensuring delivery of the desired quantity of air. The optimized blade design minimizes sound and pressure drop. Inlet Damper Removable Face LFD-2

3 Hybrid Construction Customized hybrid solutions are available, as the plenum and face material can be independently selected. A variety of materials are available, including: stainless steel, aluminum and steel. One-Piece Welded Plenum An optional one-piece welded plenum features fully welded corners to protect against infiltration of air from the ceiling plenum, as well as preventing the loss of conditioned air through seams in the diffuser casing. ½" Foil Backed Insulation Optional ½" insulation prevents the cooled and conditioned air entering the diffuser from exposure to the warm air of an unconditioned plenum space. Insulation reduces the risk of external condensation on the plenum. Foil Backed Insulation LFD Installed For more information visit LFD-3

4 Dimensional Data 5 5/8" L-1/4" W-1/4" Nominal Sizes Imperial Hard Metric Inlet Sizes W x L W x L 6,8 12in. x 24in. 300mm x 600mm 6,8 12in. x 36in. 300mm x 900mm 6,8 12in. x 48in. 300mm x 1200mm 6,8 12in. x 60in. 300mm x 1500mm 6,8 12in. x 72in. 300mm x 1800mm 6,8,10,12 24in. x 24in. 600mm x 600mm 6,8,10,12 24in. x 36in. 600mm x 900mm 6,8,10,12 24in. x 48in. 600mm x 1200mm 6,8,10,12 24in. x 60in. 600mm x 1500mm 6,8,10,12 24in. x 72in. 600mm x 1800mm Reference submittal LFD-4

5 For more information visit LFD-5

6 LFD-6

7 For more information visit LFD-7

8 Product Improvement is a continuing endeavour at Price. Therefore, specifications are subject to change without notice. Consult your Price Sales Representative for current specifications or more detailed information. Not all products may be available in all geographic areas. All goods described in this document are warranted as described in the Limited Warranty shown at priceindustries.com. The complete Price product catalog can be viewed online at priceindustries.com. Price is a registered trademark of Price Industries Limited Printed in Canada 2016.

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

HORD HOSPITAL OPERATING ROOM AIR CURTAIN HORD HOSPITAL OPERATING ROOM AIR CURTAIN The Hospital Operating Room Diffuser (HORD) air curtain system is engineered specifically for the demanding needs of operating room environments. The HORD air curtain

More information

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

HORD HOSPITAL OPERATING ROOM AIR CURTAIN HORD HOSPITAL OPERATING ROOM AIR CURTAIN The Hospital Operating Room Diffuser (HORD) air curtain system is engineered specifically for the demanding needs of operating room environments. The HORD air curtain

More information

LFDCX LAMINAR FLOW DIFFUSER WITH INTEGRATED HEPA FILTER

LFDCX LAMINAR FLOW DIFFUSER WITH INTEGRATED HEPA FILTER LFDCX LAMINAR FLOW DIFFUSER WITH INTEGRATED HEPA FILTER The low profile (LFDCX) is designed to suit the critical requirements of modern cleanrooms. The LFDCX provides a means of controlling particle contamination

More information

HGPL HOSPITAL GRADE LAMINAR FLOW COMMON PLENUM

HGPL HOSPITAL GRADE LAMINAR FLOW COMMON PLENUM HOSPITAL GRADE LAMINAR FLOW COMMON PLENUM The (HGPL) is an integrated plenum system that uses multiple laminar flow diffusers connected by a common plenum to act as a single large diffuser array. The single

More information

RPD ROUND PLAQUE DIFFUSER

RPD ROUND PLAQUE DIFFUSER ROUND PLAQUE DIFFUSER s (RPD) provide a balance between engineering and architectural needs, with a flush appearance and superior VAV performance in both ceiling and exposed duct mounting applications.

More information

RSD Series Radial Slot Diffuser

RSD Series Radial Slot Diffuser RSD Series Radial Slot Diffuser Typical Applications The RSD is suitable in high turndown applications and is able to maintain occupant comfort over a wide airflow range in cooling. With adjustable pattern

More information

Price O.R. Systems AIR CURTAIN SYSTEM

Price O.R. Systems AIR CURTAIN SYSTEM Price O.R. Systems AIR CURTAIN SYSTEM The Price Air Curtain System includes non-aspirating laminar flow diffusers directly above the surgical area with a surrounding four-sided linear slot diffuser system

More information

EGG CRATE RETURN GRILLE

EGG CRATE RETURN GRILLE 80 EGG CRATE RETURN GRILLE 80 The 80 Series is available in various mounting styles and features sturdy construction, consisting of a heavy gauge aluminum grid core, optional extruded aluminum borders

More information

SPD SQUARE PLAQUE DIFFUSER

SPD SQUARE PLAQUE DIFFUSER SQUARE PLAQUE DIFFUSER The (SPD) has a flush appearance, making it ideal for architecturally-conscience commercial spaces, and provides industry-leading low pressure drop and sound generation with a 360

More information

LAMINAR FLOW DIFFUSER Model DLAB

LAMINAR FLOW DIFFUSER Model DLAB Laminar & Radial Flow Diffuser LAMINAR FLOW DIFFUSER Model DLAB Application Laminar Flow diffusers are used to deliver air to surface directly underneath in a non-aspirating air pattern, with the minimum

More information

ULTRASUITE. Operating Room Diffuser System with Integrated LED Lighting

ULTRASUITE. Operating Room Diffuser System with Integrated LED Lighting ULTRASUITE Operating Room Diffuser System with Integrated LED Lighting ULTRASUITE Ultrasuite is a customizable air distribution and lighting solution specifically engineered for hospital operating rooms.

More information

FDCLP2 Constant Volume Series Flow, Low Profile

FDCLP2 Constant Volume Series Flow, Low Profile The Price low profile series fan powered terminal unit is an ideal product for use in typical series fan powered applications with limited ceiling space. The is designed for constant air volume applications,

More information

HORD INSTALLATION & SERVICE MANUAL. Hospital Operating Room Diffusers INSTALLATION & SERVICE MANUAL. Date: 06 / 12 Reference # : E-10 1

HORD INSTALLATION & SERVICE MANUAL. Hospital Operating Room Diffusers INSTALLATION & SERVICE MANUAL. Date: 06 / 12 Reference # : E-10 1 HORD Hospital Operating Room Diffusers Date: 06 / 12 Reference # : E-10 1 2 Table of Contents Prior to Installation... 4 Ductwork Layout... 4 Installation of HORD Air Curtain System...5-9 T-Bar Ceiling...5-6

More information

Hospital Grade Laminar Flow Common Plenum Ceiling System

Hospital Grade Laminar Flow Common Plenum Ceiling System MANUAL INSTALLATION Hospital Grade Laminar Flow Common Plenum Ceiling System HGPL Series v001 Issue Date: 11/15/17 2017 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview

More information

MANUAL INSTALLATION. Active Chilled Beam Linear. ACBL Series. v101 Issue Date: 04/10/ Price Industries Limited. All rights reserved.

MANUAL INSTALLATION. Active Chilled Beam Linear. ACBL Series. v101 Issue Date: 04/10/ Price Industries Limited. All rights reserved. MANUAL INSTALLATION Active Chilled Beam Linear ACBL Series v11 Issue Date: 4/1/18 218 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview Before You Start...1 Maintenance...1

More information

critical environment diffusers

critical environment diffusers FlowBar Critical Environment Diffusers Hard Diffusers Ceiling Table Applications of Contents 2 CRITICAL ENVIRONMENT DIFFUSERS Critical Environment Diffusers... 3 Applications... 3 General Clean Room Information...

More information

LINEAR SLOT DIFFUSERS PLENUMS

LINEAR SLOT DIFFUSERS PLENUMS LINEAR SLOT DIFFUSER PLENUMS ADAPTORS FOR MODEL SERIES 5000 LINEAR SLOT CEILING DIFFUSERS Standard Models: 5350(I) 1/2" (13) Slot 5375(I) 3/4" (19) Slot 5310(I) 1" (25) Slot Modified Performance Models:

More information

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive Centrifugal Inline s Models SQ-M and BSQ-M Direct and Belt Drive July 2010 Centrifugal Inline Duct s Greenheck's model SQ-M and BSQ-M centrifugal square inline fans feature a unique combination of installation

More information

CUSTOM FLOW ARCHITECTURAL SLOT DIFFUSER

CUSTOM FLOW ARCHITECTURAL SLOT DIFFUSER ARCHITECTURAL SLOT DIFFUSER Custom Flow (CF) slot diffusers are uniquely designed for curving and long continuous installations. The CF offers a large range of airflow flexibility with one or two slot

More information

KVR Capture Jet. KVR- Capture Jet Round Island Hood with Perimeter Jets. Round Island Hood with Perimeter Jets

KVR Capture Jet. KVR- Capture Jet Round Island Hood with Perimeter Jets. Round Island Hood with Perimeter Jets KVR Capture Jet Round Island Hood with Perimeter Jets The KVR Round Island Capture Jet hood with perimeter jets is a highly efficient kitchen ventilation hood that removes contaminated air and excess heat

More information

MODULAR CORE CEILING DIFFUSERS

MODULAR CORE CEILING DIFFUSERS MOEL SQUARE 12345-10 MOULAR CORE SQUARE IFFUSERS ROUN NECK SQUARE 1, 2, 3 OR ROUN 4-WAY AJUSTABLE NECK SQUARE ISCHARGE ROUN PATTERN NECK Steel Model: 7500 Suffix '-O' adds a steel opposed blade damper

More information

Healthcare Solutions Room Pressure Monitors and Controls

Healthcare Solutions Room Pressure Monitors and Controls Healthcare Solutions Room Pressure Monitors and Controls TOUCHSCREEN ROOM PRESSURE MONITOR The Touchscreen Room Pressure Monitor (PMT) provides precise room pressure monitoring for critical spaces such

More information

SECTION AIR TERMINAL UNITS

SECTION AIR TERMINAL UNITS SECTION 23 36 00 AIR TERMINAL UNITS PART 1 - GENERAL 1.1 SUMMARY A. Section includes constant volume terminal units, variable volume terminal units, dual duct terminal units, fan powered terminal units,

More information

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101) 500-YH SINGLE DUCT AIR TERMINAL UNIT FORM 130.12-EG1 (1101) Table of Contents General Description.......................................................................3 500-YH Features........................................................................4-5

More information

KVM KVM. Capture Jet Hybrid Backshelf Hood. Capture Jet TM Hybrid Backshelf Hood

KVM KVM. Capture Jet Hybrid Backshelf Hood. Capture Jet TM Hybrid Backshelf Hood Capture Jet Hybrid Backshelf Hood The hybrid backshelf model of Capture Jet hood is a highly efficient kitchen ventilation hood that removes contaminated air and excess heat emitted by cooking equipment,

More information

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404) 500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT Table of Contents Introduction...3 500-YVI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor Amperage

More information

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume PennBarry Fan Guide Specification Laboratory Exhaust System: Model vplume This document 2018 PennBarry vplume is a commercial lab exhaust fan that ensures a greater margin of safety by effectively dispersing

More information

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc. ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT 15 Metal Industries, Inc. BENEFITS: Fan powered terminals are typically used for heating and cooling of perimeter zones.

More information

D1-2. Table of Contents MODULAR CORE DIFFUSERS. 1240, Introduction & Product Description... D1-3. Dimensional Information...

D1-2. Table of Contents MODULAR CORE DIFFUSERS. 1240, Introduction & Product Description... D1-3. Dimensional Information... D Table of Contents, These supply, ceiling diffusers feature four handremovable modular cores. Available in steel or aluminum construction. P, P These supply, ceiling diffusers feature four handremovable

More information

Integrated 1/4" Pressure Port (Balancing/commissioning) (Accessible From Face Side) Cooling Water Connections

Integrated 1/4 Pressure Port (Balancing/commissioning) (Accessible From Face Side) Cooling Water Connections Dimensional Data Integrated 1/4" Pressure Port (Balancing/commissioning) (Accessible From Face Side) Heating Water Connections (Not Supplied On 2 Pipe) Primary Air Connection (D - 1/8") 4 Way Air Discharge

More information

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404) 500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT Table of Contents General Information...3 500-YCI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor

More information

FS Fan-Coil Units Hi-Rise, Vertical

FS Fan-Coil Units Hi-Rise, Vertical FS Fan-Coil Units Hi-Rise, Vertical FSC Concealed Dimensional Data 4-PIPE 2-PIPE TOP VIEWS Page Trims Short (5/8") Here! SIDE VIEW FRONT VIEW Dimensions Unit Size A B Single/Double Supply C D E 03 & 04

More information

forward curved inline duct blowers

forward curved inline duct blowers Defining Innovation. forward curved inline duct blowers TYPE DBS (Single) DBT (Twin) BULLETIN 4220 January 2011 Duct Blowers General Information Twin City Fan s belt driven DBS (single) and DBT (twin)

More information

STEEL LOUVERED DIFFUSERS [CFM Range is only a guide. See Manufacturer Catalog for complete data. All NC Levels in Acceptable Range<32.

STEEL LOUVERED DIFFUSERS [CFM Range is only a guide. See Manufacturer Catalog for complete data. All NC Levels in Acceptable Range<32. STEEL LOUVERED DIFFUSERS TUTTLE & BAILEY Model 1300 - Round Neck Steel, Lay-In Tee Bar Mounting Neck Size Panel Size CFM Range Price Each Volume Damper Model RBN *6 12 x 12 75-180 $19 $12 6 24 x 24 75-180

More information

RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL

RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL RAVS RARM RARS RAVE RAVM RAVL RARP RISER www.superiorrex.com RAV Series: VERTICAL HI-RISE CONCEALED SO TOUGH, WE GUARANTEE IT! www.superiorrex.com Model

More information

INDEX. Chapter1 0. air master. Round Ceiling Diffusers

INDEX. Chapter1 0. air master. Round Ceiling Diffusers air master Chapter1 0 INDEX A. Round ceiling diffusers 1. Fixed round ceiling diffuser...: ARDF...10.1 2. Round ceiling diffuser with adjustable pattern...: ARD...10.2 Standard sizes...10.3 Air pattern...10.3

More information

FAN POWERED TERMINAL UNITS

FAN POWERED TERMINAL UNITS Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and

More information

Linear diffuser SAL 50 Submittal

Linear diffuser SAL 50 Submittal Linear diffuser SL 0 Submittal The SL0 is a diffuser with 0mm profiles wide. It is composed of extruded aluminum surfaces with eccentric rollers which slide inside and are mounted on the plenum, as well

More information

Model ND-2 Specification

Model ND-2 Specification Model ND-2 Specification The model ND-2 is an exhaust only canopy hood rated for all types of cooking equipment. The hood shall have the size, shape and performance specified on drawings. Construction

More information

XeteX, Inc. All Rights Reserved.

XeteX, Inc. All Rights Reserved. Model XC Indoor or outdoor mounted, simple, in-case aluminum flat plate exchanger with options for frost control. Ideal for inline installations: in duct-work systems, in built-up units, or in modular

More information

Laboratory Solutions. pricecriticalcontrols.com

Laboratory Solutions. pricecriticalcontrols.com Laboratory Solutions pricecriticalcontrols.com Laboratory Solutions Laboratory Space Controller Native BACnet MS/TP (BTL Listed) High speed room level network Control multiple supply and general exhaust

More information

TVS/R FAN COIL UNITS HI-RISE, VERTICAL

TVS/R FAN COIL UNITS HI-RISE, VERTICAL TVS/R FAN COIL UNITS HI-RISE, VERTICAL TVRM TVRP Riser TVRS TVSE TVSM TVSR TVSS Redefine your comfort zone. www.titus-hvac.com Redefine your comfort zone www.titus-hvac.com Model TVS/R: CONCEALED, HI-RISE

More information

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER MEL TXD Model Features Exhaust air up to 3,400 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

KVL-P with Plate Shelf

KVL-P with Plate Shelf The model of Capture Jet TM hood is a highly efficient kitchen ventilation hood that removes contaminated air and excess heat emitted by cooking equipment, helping to provide a comfortable and clean environment.

More information

Application Guidelines

Application Guidelines Grilles and Registers Application Guidelines Introduction Overview It is the intent of this section to give some basic application guidelines for the use of supply and return grilles and registers in a

More information

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499] BC--1.0 03-01-1 Belt Drive Blower Coil Unit, Basic Unit Discharge ARGT. 1 4. See page 1 for filter rack details. 5. Base rail is optional on he base unit. See page 13. Base rails must be used with mixing

More information

LINEAR DIFFUSERS AND BAR GRILLES

LINEAR DIFFUSERS AND BAR GRILLES 49-240 48LL1 49-280 49-480 48LL2 Linear ar Grilles The Nailor 4900 Series provides an extruded aluminum bar grille that offers beautiful styling and efficient performance. Linear bar grilles offer a choice

More information

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410. PART 1 - GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

LAMINAR FLOW HORIZONTAL FLOW BENCH (LF) OPERATION & MAINTENANCE MANUAL

LAMINAR FLOW HORIZONTAL FLOW BENCH (LF) OPERATION & MAINTENANCE MANUAL LAMINAR FLOW HORIZONTAL FLOW BENCH (LF) OPERATION & MAINTENANCE MANUAL ENVIRCO Technical Support: 800-884-0002 Table of Contents WARNING... 3 INTRODUCTION... 3 FEATURES... 4 APPLICATIONS... 4 ASSEMBLY...

More information

Requires Ductwork and Blower

Requires Ductwork and Blower 6' Protector XStream Laboratory Hood 9840600 is shown with SpillStopper Work Surface 9849800, Protector Acid Storage Cabinet 9901100 and Protector Standard Storage Cabinet 9900100. Requires Ductwork and

More information

fsfdfsdfsdfssfsf OMNI DIFFUSER

fsfdfsdfsdfssfsf OMNI DIFFUSER fsfdfsdfsdfssfsf OMNI DIFFUSER Architectural Ceiling Diffusers diffusers OMNI The Titus OMNI diffuser satisfies architectural as well as engineering criteria. Its strong, clean, unobtrusive lines harmonize

More information

University of Delaware

University of Delaware SECTION 23 36 00 _ SUMMARY PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Constant/Variable volume supply terminal units. 2. Fan powered terminal units. 3. Exhaust valves B. Related Sections: Section

More information

INDOOR ENVIRONMENTAL SOLUTIONS

INDOOR ENVIRONMENTAL SOLUTIONS Specifications & Engineering Guide INDOOR ENVIRONMENTAL SOLUTIONS Introduction New High Performance Diffuser Technology Warren Technology has developed a new, technological breakthrough in air distribution

More information

PERFORATED CEILING DIFFUSERS

PERFORATED CEILING DIFFUSERS PERFORAE PERFORAE CURVE MOEL BLAE 12345-10 IFFUSERS SQUARE ROUN NECK SQUARE SUPPLYROUN NECK 4-WAY AJUSABLE ISCHARGE SQUARE ROUN NECK PAERN (SANAR) 1, 2 OR 3-WAY ISCHARGE PAERN (OPIONAL) Steel Models: 4320CB

More information

Inline and Roof Mounted Fans

Inline and Roof Mounted Fans CV Inline and Roof Mounted Fans Page Introduction........................................... 2 Construction Features................................. 3-4 Specifications and Dimension Data CVD (Direct Drive

More information

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector Protector XStream Laboratory Hood 9840600 is shown with SpillStopper Work Surface 9849800, Protector Acid Storage Cabinet 9901100 and Protector Standard Storage Cabinet 9900100. Protector XStream Laboratory

More information

DCG Adjustable Aluminum Round Diffusers

DCG Adjustable Aluminum Round Diffusers 51 DCG Adjustable Aluminum Round Diffusers H V A C TM Rev 27-05-2018 52 DCG SEries Aluminum Adjustable Round Diffusers Adjust core up and down to move from horizontal to vertical airflow Architecturally

More information

PERFORATED CEILING DIFFUSERS

PERFORATED CEILING DIFFUSERS PERFORAE MOEL PERFORAE 12345-10 CEILING SQUARE IFFUSERS ROUN NECK SQUARE ROUN NECK SUPPLY SQUARE 1, 2, 3 OR ROUN 4-WAY AJUSABLE NECK ISCHARGE PAERN Steel Models: 4320 Flush Face 4325 rop Face Aluminum

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the industry s best performance and durability

More information

Concentric Supply/Return Diffusers. Models CSR & CSR-P. Redefine your comfort zone.

Concentric Supply/Return Diffusers. Models CSR & CSR-P. Redefine your comfort zone. Concentric Supply/Return Diffusers Models CSR & CSR-P Redefine your comfort zone. www.titus-hvac.com Concentric Supply/Return Diffusers Models CSR & CSR-P Plenum CSR Rectangular Ceiling Diffuser Combination

More information

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES FAN TERMINAL UNIT SPECIFIABLE FEATURES Galvanized steel casing, mechanically sealed for low leakage construction NEMA TYPE 1 rated hinged control enclosure with standoff to prevent penetration of casing

More information

Application Guidelines

Application Guidelines Grilles and Registers Application Guidelines Introduction Overview It is the intent of this section to give some basic application guidelines for the use of supply and return grilles and registers in a

More information

Unit Heaters. Catalog MANUFACTURERS HEATING PRODUCTS. Tel: (905) Fax: (905) OF HYDRONIC.

Unit Heaters. Catalog MANUFACTURERS HEATING PRODUCTS.   Tel: (905) Fax: (905) OF HYDRONIC. Catalog MANUFACTURERS OF HYDRONIC HEATING PRODUCTS Tel: (905) 670-3200 Fax: (905) 670-3822 General Product Overview Sigma horizontal and vertical propeller unit heaters feature a wide performance range

More information

Square/Rect. and Square Louvered Face and Plaque Face Diffuser

Square/Rect. and Square Louvered Face and Plaque Face Diffuser /Rect. and Louvered Face and Plaque Face Diffuser Series J: Easily Adjustable from Horizontal to Vertical Vertical Discharge Application: Carnes steel (SK) and aluminum (SE) louvered face diffusers are

More information

ADJUSTABLE SLOT DIFFUSER TYPE: SE800

ADJUSTABLE SLOT DIFFUSER TYPE: SE800 TYPE: SE800 Installation dimensions Construction with hanger brackets Construction without hanger brackets D C Application 7 E A 0 7 E A 0 The slot diffuser, type SE800 is used for the supply of cooled

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved B U I L D I N G V A L U E I N A I R. April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the

More information

SPV / SDV Series SINGLE DUCT TERMINAL UNITS

SPV / SDV Series SINGLE DUCT TERMINAL UNITS SPV / SDV Series SINGLE DUCT Price single duct terminal units are designed to control the airflow rate of conditioned air into an occupied space with minimal pressure drop and low noise levels. An extensive

More information

TH Series UL 900 Class 1, Factory Mutual Approved, Truly Separatorless Filter Modules

TH Series UL 900 Class 1, Factory Mutual Approved, Truly Separatorless Filter Modules FOREMOST IN AIR FILTRATION TH Series UL 900 Class 1, Factory Mutual Approved, Truly Separatorless Filter Modules Bulletin: PB1500-0511 General Flanders TH Series HEPA/ULPA Filter Modules are lightweight

More information

3.5 Exposure Control Measures

3.5 Exposure Control Measures 3.5 Exposure Control Measures 3.5.1 Chemical Fume Hoods Chemical fume hoods are the most reliable and primary engineering control used in the laboratory to protect against the inhalation of hazardous vapors

More information

ANATOMY DISSECTION TABLES

ANATOMY DISSECTION TABLES ANATOMY DISSECTION TABLES SECTION 8 ANATOMY DISSECTION TABLES Standard Dissection Platform... 2 Economy Dissection Platform... 3 Dissection Table w/ Hood... 4-5 Height Adjustable Dissection Table w/ Hood...

More information

GRD PRODUCT CATALOG DISPLACEMENT VENTILATION PRODUCTS

GRD PRODUCT CATALOG DISPLACEMENT VENTILATION PRODUCTS GRD PRODUCT CATALOG PRODUCTS 2018 Metal Industries, Inc. PRODUCTS Displacement Ventilation systems provide conditioned air at floor level at very low velocity and allow heat sources within the room (like

More information

Slot diffusers, Round duct diffusers. IMP Klima

Slot diffusers, Round duct diffusers. IMP Klima , Round duct diffusers 04 Round duct diffusers 176 , Round duct diffusers SLOT DIFFUSERS, ROUND DUCT DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS CIRCULAR DIFFUSERS, SQUARE DIFFUSERS VENTILATING

More information

Centrifugal Utility Fans - SFD/SFB

Centrifugal Utility Fans - SFD/SFB C H F D B G E A Centrifugal Utility Fans - SFD/SFB SFB STANDARD CONSTRUCTION FEATURES HOUSING: Heavy gauge steel housing with Lock-seam construction Unit support angles with prepunched mounting holes Adjustable

More information

LINEAR SLOT DIFFUSERS

LINEAR SLOT DIFFUSERS OVERVIEW CHARACTERISTICS APPLICATIONS OVERVIEW : The series linear diffusers allow to manage high air flows with minimum pressure losses and generated noise power. They allow to fully make use of the induction

More information

2/6.1/EN/1. High Induction. Variable / Constant Volume Swirl Diffuser Types HIVV HICV

2/6.1/EN/1. High Induction. Variable / Constant Volume Swirl Diffuser Types HIVV HICV 2/6.1/EN/1 High Induction Variable / Constant Volume Swirl Diffuser Types HIVV HICV Contents Description Description... Specification Dimensions... HIVV-E Operation... Quick Selection Table... Technical

More information

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades X X testregistrierung Type Vertical air discharge Horizontal air discharge For large temperature differences in heating mode, high penetration of air, with adjustable air control blades Circular ceiling

More information

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER MEL TXD MEL FEATURES Exhaust air up to 3,400 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

Complete HVAC Capability

Complete HVAC Capability Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option

More information

Premium Correctional Air Distribution. The First Name in Air Diffusion.

Premium Correctional Air Distribution. The First Name in Air Diffusion. Premium Correctional Air Distribution The First Name in Air Diffusion www.anemostat.com PRODUCT DIRECTORY APPLICATIONS Stainless Steel S-Vent MAXIMUM SECURITY GRILLES NEW CONSTRUCTION page 16 page 4 &

More information

F1-2. Table of Contents PLENUM SLOT DIFFUSERS PTBS. Introduction & Dimensional Information... F1-3. Accessories... F1-54. Reference Charts...

F1-2. Table of Contents PLENUM SLOT DIFFUSERS PTBS. Introduction & Dimensional Information... F1-3. Accessories... F1-54. Reference Charts... F1 LENUM LO DIFFUE able of ontents his plenum slot supply diffuser features an adjustable blade. lots: 1 to 4 lot Widths: ¾, 1, 1½ Introduction & Dimensional Information... F13 Accessories... F15 eference

More information

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes:

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes: Perforated Ceiling Diffusers OPTIMA ceiling diffuser with perforated face, are recoended for heating, ventilating and cooling in centralized air conditioning systems. Perforated face diffusers, with 4-3-

More information

GRAVITY INTAKE AND EXHAUST ROOF VENTILATORS

GRAVITY INTAKE AND EXHAUST ROOF VENTILATORS GRAVITY INTAKE and EXHAUST ROOF VENTILATORS SECTION 21 GRAVITY INTAKE AND EXHAUST ROOF VENTILATORS Series GE and GI Low Silhouette This attractive low silhouette design is available in specific versions

More information

VAV TERMINAL UNITS. VVD VAV Diffusers

VAV TERMINAL UNITS. VVD VAV Diffusers Introduction ASLI VAV diffusers, VVD are variable air volume diffuser for supply air in variable air volume system. In many conventional HVAC systems, multiple work spaces are controlled by a single thermostat.

More information

DRUM JET DIFFUSERS TYPE: DJA DJB DJAP DJBP

DRUM JET DIFFUSERS TYPE: DJA DJB DJAP DJBP TYPE: DJA DJB DJAP DJBP APPLICATION Type DJ As with type AJ diffusers, this product is also designed to project large volumes of air over long distances, but particularly lends itself to sidewall or ductmounting,

More information

Catalog Linear Diffuser SAL 50

Catalog Linear Diffuser SAL 50 Catalog 3 Linear Diffuser SAL 50 content SAL 50 Model Description, areas of application and benefits Configuration and operation mode 2 Air flow direction 3 Selection of the number of slots 4 Diagrams

More information

SECTION LABORATORY FUME HOODS UNIFLOW LE SERIES

SECTION LABORATORY FUME HOODS UNIFLOW LE SERIES SECTION 11610.1 LABORATORY LE FUME HOODS UNIFLOW LE SERIES REVISED AUGUST 2, 2013 LABORATORY FUME HOODS UNIFLOW LE SERIES PART 1 GENERAL 1.00 SUMMARY A. Section Includes: 1. Laboratory Fume Hoods B. Related

More information

1 of 5. Hepa Technologies Sdn. Bhd. AmAir 300X, RigiFil, AstroCel I. VariCel II

1 of 5. Hepa Technologies Sdn. Bhd. AmAir 300X, RigiFil, AstroCel I. VariCel II Hepa Technologies Sdn. Bhd. AmAir 300X, RigiFil, AstroCel I AmAir 300X AmAir 300X filters are constructed with AAF's totally unitized, double wall, moisture resistant die-cut beverage frame. The media

More information

DRUM LOUVERS DRUM LOUVERS 45DL SERIES. Models: 45DL1 Single Vanes 45DL2 Split Vanes G151 HIGH CAPACITY LONG THROW ALUMINUM CONSTRUCTION

DRUM LOUVERS DRUM LOUVERS 45DL SERIES. Models: 45DL1 Single Vanes 45DL2 Split Vanes G151 HIGH CAPACITY LONG THROW ALUMINUM CONSTRUCTION DRUM LOUVERS 45DL SERIES HIH CAPACITY LON THROW ALUMINUM CONSTRUCTION Models: Single Vanes 45DL2 Split Vanes Suffix '-O' adds a steel opposed blade damper Models -O and 45DL2 Model Series 45DL Drum Louvers

More information

MIN/MAX PERFORMANCE IN INCHES WG

MIN/MAX PERFORMANCE IN INCHES WG Fans Roof Exhaust Direct Drive - G Model G Centrifugal Roof Exhaust fans are direct drive. These fans are specifically designed for roof mounted applications exhausting relatively clean air. Fan wheels

More information

Compounding Safety Solutions.

Compounding Safety Solutions. Compounding Safety Solutions HRT, Pain, & Vet Compounding PowderSafe Type A Enclosure AirClean Systems PowderSafe Type A enclosures are designed to provide operator protection from hazardous compounds

More information

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section SECTION 15910 DUCT ACCESSORIES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract including General and Supplementary Conditions, Division-1 Specification Sections,

More information

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan GRAVITY VENTILATORS MGI & MGR GRV TEL & TIL LUG CATALOG 4720 MAY 2014

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan GRAVITY VENTILATORS MGI & MGR GRV TEL & TIL LUG   CATALOG 4720 MAY 2014 Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS GRAVITY VENTILATORS MGI & MGR GRV TEL & TIL LUG CATALOG 4720 MAY 2014 WWW.TCF.COM GRAVITY VENTILATORS Overview Gravity Ventilators Models

More information

for Pleasant & Healthy Air-Distribution ISO 9001:2000 Linear Bar & Floor Grilles Product Bulletin 135-D

for Pleasant & Healthy Air-Distribution   ISO 9001:2000 Linear Bar & Floor Grilles Product Bulletin 135-D for Pleasant & Healthy Air-Distribution ISO 90012000 Product Bulletin 135-D Linear Bar & Floor Grilles Pleasant.. Serene.. YOU & DASCO... Since 1964 Partners for good health INTRODUCTION DASCO Linear Bar

More information

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS Air Zoë Centrifugal Inline Duct fans have been developed to efficiently handle the

More information

PURCHASE SPECIFICATIONS FOR NUAIRE PHARMAGARD NU-NR797 NEGATIVE PRESSURE RECIRCULATING STERILE ISOLATOR

PURCHASE SPECIFICATIONS FOR NUAIRE PHARMAGARD NU-NR797 NEGATIVE PRESSURE RECIRCULATING STERILE ISOLATOR PURCHASE SPECIFICATIONS FOR NUAIRE PHARMAGARD NU-NR797 NEGATIVE PRESSURE RECIRCULATING STERILE ISOLATOR The intent herein is to provide a concise statement of requirements for a quality negative pressure

More information

Direct Gas-Fired Heating

Direct Gas-Fired Heating Direct Gas-Fired Heating Model DG 800 to 15,000 cfm Up to 1,600,000 BTU/hr Optional Evaporative Cooling January 2005 PRODUCT FEATURES Model DG Direct Gas-Fired Make-Up Air Unit The Greenheck model DG is

More information

HOOD ACCESSORIES HOOD ACCESSORIES HOOD ACCESSORIES

HOOD ACCESSORIES HOOD ACCESSORIES HOOD ACCESSORIES HOOD ACCESSORIES 58 59 VAPORPROOF RECESSED INCANDESCENT LIGHT FIXTURE VAPORPROOF LIGHT FIXTURES RECESSED INCANDESCENT LIGHT FIXTURE Specifications Cut-Out Mounting Diagram Socket: Side mounted porcelain

More information

PSTI High Induction Diffuser

PSTI High Induction Diffuser PSTI High Induction Diffuser Barcol-ir is continuously aiming to optimize construction and quality for all equipment. Barcol-ir has the right to adjust the product specifications without any obligation

More information

Catalog Swirl diffuser DAL 359

Catalog Swirl diffuser DAL 359 Catalog 1.1.1 DAL 359 Restaurant, Lingen, Germany DAL 359 Model Description, area of application and product benefits............ DAL 359 1 Configuration...................................................

More information

(click on page links below) General & Performance Data 1. Suggested Spec 3. Accessories 4

(click on page links below) General & Performance Data 1. Suggested Spec 3. Accessories 4 HAR Variable Air Volume Diffusers Contents: (click on page links below) General & Performance Data 1 Suggested Spec 3 Accessories 4 AUCKLAND ph 09 279 5250 fax 09 275 5637 sales@temperzone.co.nz WELLINGTON

More information