1 January 17, a HIGH PRESSURE SOLENOID VALVE Max i mum 250 PSI (1 724 kpa) 1. PRODUCT NAME High Pressure Solenoid Valve For Max i mum 250 psi (1 724 kpa) Wa ter Working Pressure 2. MANUFACTURED FOR: The Vi king Cor po ra tion 210 N. Industrial Park Road Hastings, Michigan U.S.A. Tele phone: (616) (877) Fax: (616) techsvcs@vikingcorp.com 3. PRODUCT DESCRIPTION The high pressure solenoid valve is a two-way type with one inlet and one outlet. It is a packless, internal pilot operated valve, suitable for use in releasing water pressure from the priming chamber of Viking Model E Series Deluge Valves and Viking Model H Series Flow Control Valves. The solenoid valve has floating diaphragm construction, which requires a minimum pressure drop across the valve to operate properly. This valve is available normally closed and has a voltage rating of 24 volt DC. This solenoid valve is for use with system control units that are listed and/or approved for releasing service for water based fire protection systems. 4. AP PROVALS See Ta ble 1 on page 217 b. MA TE RIALS Body: Brass with ½" (15 mm) NPT connections Seals and Discs: Buna N Core Tube: 305 Stainless Steel Core and Plugnut: 430F Stainless Steel Springs: 302 Stainless Steel Coil: Class H, Continuous Duty Maximum Operating Pressure: 250 psi (1 724 kpa) Minimum Operating Pressure: Form No. F_ See Ta ble 1 for enclosure descriptions and recommended ambient temperatures. Manufacturer: Automatic Switch Company (ASCO) Straight Body Styles are ASCO Bul le tin 8210 Di a phragm Type Valves (Red-Hat or Red-Hat II Models) 5. FEATURES AND ACCESSORIES A. Normally closed. B. 24 VDC Standard C. Easy to clean. D. Required Ac ces sories: A 50 mesh strainer must be installed on the inlet side of the valve at the priming line connection. This strainer is included as part of the Model E-1 Deluge Valve Trim and Model H Flow Control Valve Trim. E. NEMA 1 through 9. (See Ta ble 1 on page 217b.) 6. OPERATION The solenoid valve is an internal pilot operated valve with pilot and bleed orifices utilizing line pressure for operation. Normally closed, de-energized valves open when energized. Power is applied to the solenoid coil, causing the solenoid core to lift, opening the pilot orifice to the outlet side of the valve. This relieves pressure on the top side of the diaphragm and allows the line pressure to open the valve. When de-energized, the solenoid core reseals the pilot orifice, allowing the line pressure to build above the diaphragm, closing the valve. Normally closed solenoid valves are commonly used as releases for Viking deluge and flow control valves. Opening the solenoid valve allows the deluge or flow control valve to open. Note: When using a normally closed solenoid valve as a release, a system will not operate automatically on total loss of power. For this reason, it is recommended and normally required that an emergency back-up, supervised power supply be provided to maintain fire protection during interruptions of the main power system and to meet the requirements of appropriate Authorities Having Jurisdiction. 7. AVAILABILITY AND SERVICE The so le noid valve is avail able through a net work of do mes tic and in ter na tional distributors. See the Yellow Pages of the telephone directory for a local distributor (listed under Sprinklers-Automatic- Fire ) or contact Vi king Tech ni cal Data may be found on The Vi king Cor po ra tion s Web site at The Web site may in clude a more re cent edi tion of this Tech ni cal Data page. 8. GUAR AN TEES For details of warranty, refer to Viking s current list price schedule or contact 9. MAINTENANCE WARNING: The owner is re spon si ble for main tain ing the fire pro tec tion sys - tem in proper op er at ing con di tion. Any system maintenance or testing that involves placing a control valve or detection system out of service may eliminate the fire protection of that system. Prior to proceeding, notify all Authorities Having Jurisdiction. Consideration should be given to employment of a fire patrol in the affected area. WARNING: Prior to op er at ing the so le - noid valve, be sure to close the sys tem con trol valve to avoid un in ten tional op - er a tion of the de luge valve. A. In spec tions: It is im per a tive that the sys tem be in spected and tested on a reg u lar ba sis. The fre quency of the in spec tions may vary due to con tam - i nated wa ter sup plies, cor ro sive wa - ter sup plies, or cor ro sive at mo - spheres. In ad di tion, the alarm de - vices, de tec tion sys tems, or other con nected trim may re quire a more fre quent sched ule. Re fer to the sys - tem de scrip tion and ap pli ca ble codes for min i mum re quire ments. B. The valve must be operated at least monthly. The valve must open and close freely. When open, the water flow must be clear and clean at the proper flow rate. When closed, a total water shut-off must be observed. After the test, the strainer must be cleaned. Prior to cleaning the strainer, the priming line valve must be closed and the priming line depressurized. After the strainer is cleaned, the priming line valve must be reopened. C. The valve must be inspected at least monthly for cracks, corrosion, leakage, etc., and cleaned, repaired, or replaced as necessary. D. At least an nu ally, the valve diaphragms and seats must be in - spected and if nec es sary, re paired or re placed. WARNING: Close sys tem con trol valve, turn off power sup ply, and depressurize valve be fore dis as sem - bling valve. It is not nec es sary to re - Replaces page 217 a-d, dated April 29, (Added new ex plo sion-proof so le noid valves and new 110V/50Hz and 120V/60Hz so le noid valves).
2 217 b January 17, 2000 HIGH PRESSURE SOLENOID VALVE Max i mum 250 PSI (1 724 kpa) move the valve from the pipe line to make in spec tions. E. When lu bri cat ing valve com po nents, use a high grade sil i cone grease (Dow Corning 111 Com pound Lu - bri cant or equal). F. When reassembling, tighten parts to torque val ues in di cated in ASCO s main te nance in struc tions (packed with valve). G. Af ter main te nance is com pleted, op er ate the valve a few times to be sure of proper op er a tion. A me tal lic click sig ni fies the so le noid is op er - at ing. H. It is recommended that the valve be replaced at seven-year in ter vals. Shorter intervals may be required if the valve is subject to corrosive water supplies or atmospheres. I. All service must be performed by qualified per son nel. Upon com ple tion of in spec tions or re place ment of the Viking P/N ASCO Catalogue Number Orifice Body Style 1 Enclosure Type (NEMA Rating) HV /4" Straight 4, and 4X NC 24 DC 3, 3S,, HV /4" Straight 6, 6P, NC 24 DC 110V/50 Hz HV /4" Straight 4, and 4X NC 120V/60 Hz 3, 3S,, 110V/50 Hz HV /4" Straight 6, 6P, NC 120V/60 Hz valve, the en tire sys tem must be checked for proper op er a tion. See ap pro pri ate sys tem de scrip tion and test ing in struc tions for ad di tional in - for ma tion. 10. INSTALLATION A. Check nameplate for correct unit, including voltage and mode of operation. Follow all installation and maintenance instructions enclosed with the valve. B. Standard solenoids may be mounted in any position. However, for optimum life and performance, solenoids should be mounted vertically and upright with the coil upright. C. A 50 mesh strainer is required on the inlet side of the valve at the priming line connection. This strainer is included as part of the Model E-1 Deluge Valve Trim. Install the strainer Description (Deenergized) Voltage Watts DC AMPS 22.6 DC DC AC See Note AC See Note 7 Footnotes Minimum Operating Pressure Differential 3 as indicated on Viking s trim draw - ing. In stall the solenoid according to markings on the valve body. Apply pipe-joint compound sparingly to male pipe threads only. If applied to valve threads, it may enter the valve and cause operation difficulty or leakage. Avoid putting pipe compound on first two male threads as well. D. The unit must be wired in accordance with local and national electrical codes. For valves equipped with water tight enclosures, the electrical fittings must be approved for use in the hazardous location. E. Upon com plet ing the installation, the entire sys tem must be tested for proper op er a tion. See sys tem de - scrip tion and test ing in struc tions for ad di tional in for ma tion. Maximum Ambient Temp. 4 Cv Factor Listings/Approvals UL CSA 5 FM (54 C) 4.0 Yes 10 Yes Yes 6 (54 C) 4.0 No 8 Yes No 8 (54 C) 4.0 Yes 10 Yes No 9 (54 C) 4.0 No 8 Yes No 9 Over all take-out (end of in let nip ple to end of out let nip ple) = 2-13/16 (71,4 mm). All valves have ½ (15 mm) NPT con nec tions. En clo sure type: 1 (Gen eral Pur pose) 2 (Drip-Proof), 3 and 3S (Raintight), 4 and 4X (Wa ter tight), 6 and 6P (Sub mers ible), 7 (Ex plo sion- Proof, Class I, Groups A, B, C, and D), 9 (Dust Ig ni tion-proof Class II, Groups E, F, and G) Min i mum op er at ing pres sure dif fer en tial is that re quired to open valve and keep it open. The valve will start to close be low the min i mum op er at ing pressure dif fer en tial. Min i mum Ambient Tem per a ture for all valves is 40 F (4 C). Man u fac turer s rec om mended max i mum am bi ent tem per a tures are de ter mined un der continously en er gized con di tions with max i mum fluid tem per a tures in the valves. Ac tual con di tions (such as nor mally closed and nor mally de-energized with room tem per a ture wa ter in the line) will permit use at con sid er ably higher am bi ent tem per a tures. CSA rec og nized to CSA Stan dards C22.2 num ber 0 and num ber 129. Ex plo sion-proof ver sions are CSA rec og nized to CSA Stan dards C22.2 Nos. 0, 139, 25, and 30. They are cer ti fied for Haz ard ous Lo ca tions Class I, Groups C and D; Class II, Groups E, F, and G. FM Ap proved as a com po nent of Vi king 250 psi (1 724 kpa) elec tri cally re leased De luge, Preaction, and Flow Con trol Sys tems. For AC volt ages, in rush cur rent (i.e. start plunger mov ing) =.78 volt amps. Holding cur rent (i.e. to hold plunger open) =.33 volt amps. UL List ing and FM Ap proval pend ing on Ex plo sion Proof mod els. FM does not al low 110V/50 HZ or 120V/60 Hz so le noid power sup plies for fire pro tec tion. UL Listed as Safety Shut-off (UL 429) and Fire Pro tec tion Special Sys tem Wa ter Con trol Release Ser vice (UL 429A Prod uct Cat e gory VLTR). Ta ble 1 Replaces page 217 a-d, dated April 29, (Added new ex plo sion-proof so le noid valves and new 110V/50Hz and 120V/60 Hz so le noid valves). Form No. F_052689
3 January 17, c 1. PRO DUCT NAME Replacement Solenoid Valves For Max i mum 17 (1 207 kpa) Water Working Pressure 2. MANUFACTURED FOR: The Vi king Cor po ra tion 210 N. Industrial Park Road Hastings, Michigan U.S.A. Tele phone: (616) (877) Fax: (616) techsvcs@vikingcorp.com 3. PRODUCT DESCRIPTION The solenoid valves are two-way type with one inlet and one outlet. They are packless, internal pilot operated valves suitable for use in releasing water pressure from the priming chamber of Viking Model E-1 and Model E-2 Deluge Valves and Model H-1 and Model H-2 Flow Control Valves. They have either floating diaphragm or piston type construction, which requires a minimum pressure drop across the valve to operate properly. Both normally closed and normally open valves are available. Although these valves are available in several voltages, 24 volt DC and 120 VAC models are normally stocked. These valves are to be used with system control units that are listed/approved for releasing service for water-based fire protection systems. 4. MA TE RIALS Body: Brass with ½" (15 mm) NPT connections Seals and Discs: Buna-A or Ethylene Propylene Core Tube: 305 Stainless Steel Core and Plugnut: 430F Stainless Steel Springs: 302 Stainless Steel Coil: Class F or H, Continuous Duty Maximum Operating Pressure: 17 (1 207 kpa) See Ta ble 2 for en clo sure de scrip tions and recommended ambient tempera - tures. Manufacturer: Automatic Switch Company (ASCO) Straight Body Styles are ASCO Bul le tin 8210 Di a phragm Type Valves (Red-Hat or Red-Hat II Models) An gle Body Styles are ASCO Bul le tin 8223 Pis ton Type Valves (Red-Hat Model) 5. FEATURES AND ACCESS- ORIES A. Avail able nor mally open or nor mally closed. B. Avail able in several voltages. C. Easy to clean. D. Re quired Ac ces sories: A 50 mesh strainer must be in stalled at the prim ing line con nec tion on the in let side of the valve. This strainer is in cluded as part of the Model E-1 De luge Valve Trim and Model H Flow Con trol Valve Trim. E. NEMA 1 through 9. (See Ta ble 2 on page 217d.) 6. OPERATION The solenoid valves are internal pilot operated valves with pilot and bleed orifices utilizing line pressure for operation. Normally closed, de-energized valves open when energized. Power is applied to the solenoid coil, causing the solenoid core to lift, and opening the pilot orifice to the outlet side of the valve. This relieves pressure on the top side of the diaphragm or piston and allows the line pressure to open the valve. When de-energized, the solenoid core reseals the pilot orifice, allowing the line pressure to build above the diaphragm or piston, and closing the valve. Normally-open, de-energized valves close when energized. When power is applied to the solenoid coil, the solenoid core seals the pilot orifice, allowing the line pressure to build above the diaphragm or piston, causing the valve to close. When de-energized, the solenoid core opens the pilot orifice to the outlet side of the valve. This relieves pressure on the top side of the diaphragm or piston and allows the line pressure to open the valve. Normally closed so le noid valves are com monly used as re leases for Vi king de luge and flow con trol valves. Open - ing the so le noid valve al lows the de luge or flow con trol valve to open. NOTE: When us ing a nor mally closed so le noid valve as a re lease, a sys tem will not op er ate au to mat i cally on to tal loss of power. For this rea son, it is rec - om mended and nor mally re quired that an emer gency back-up, su per vised power sup ply be pro vided to main tain fire pro tec tion dur ing in ter rup tions of the main power sys tem and to meet the re quire ments of ap pro pri ate Au thor ities Hav ing Ju ris dic tion. When nor mally open so le noid valves are used as re leases for de luge or flow con trol valves, they must be en er gized con stantly to main tain sys tems in the set con di tion; any loss or in ter rup tion of power to the so le noid valve will al low the sys tem to trip. Normally open so le - noids are used as re leases in spe cial ap pli ca tions re quir ing a fail-safe, sys - tem trip ped con di tion on to tal loss of power. An ex am ple of the prin ci pal would be Vi king s Firecycle II sys tem. Care must be taken in se lect ing the ap - pro pri ate nor mally open or normally closed so le noid valve to en sure de sired pro tec tion from fire or ac ci den tal sys - tem op er a tion. 7. AVAILABILITY AND SERVICE The solenoid valve is available through a network of domestic and international distributors. See the Yellow Pages of the telephone directory for a local distributor (listed under Sprinklers-Automatic- Fire ) or contact Vi king Tech ni cal Data may be found on The Vi king Cor po ra tion s Web site at The Web site may in clude a more re cent edi tion of this Tech ni cal Data page. 8. GUARANTEES For details of warranty, refer to Viking s current list price schedule or contact 9. MAINTENANCE WARNING: The owner is re spon si ble for main tain ing his fire pro tec tion sys - tem in proper op er at ing con di tion. Any system maintenance or testing that involves placing a control valve or detection system out of service may eliminate the fire protection of that system. Prior to proceeding, notify all Authorities Having Jurisdiction. Consideration should be given to Form No. F_ Replaces page 217 a-d, dated April 29, (Changes made to list ings and ap prov als)
4 217 d January 17, 2000 employment of a fire patrol in the affected area. WARNING: Prior to op er at ing the so le - noid valve, be sure to close the sys tem con trol valve to avoid un in ten tional op - er a tion of the de luge valve. A. Inspections: It is imperative that the system be inspected and tested on a regular basis. The frequency of the inspections may vary due to contaminated water supplies, corrosive water supplies, or corrosive atmospheres. In addition, the alarm devices, detection systems, or other connected trim may require a more frequent schedule. Refer to the system Vi king P/N ASCO Cat a logue Num ber Orifice Body Style 7 description and applicable codes for minimum requirements. B. The valve must be operated at least monthly. The valve must open and close freely. When open, the water flow must be clear and clean at the proper flow rate. When closed, a total water shut-off must be observed. After the test, the strainer must be cleaned. Prior to cleaning the strainer, the priming line valve must be closed and the priming line depressurized. After the strainer is cleaned, the priming line valve must be reopened. C. The valve must be inspected at least monthly for cracks, corrosion, leakage, Enclosure Min i mum Type De scrip tion Volt age Watts DC Maximum Op er ating Am bi ent Cv (NEMA (De-energized) AMPS Pres sure Rat ing) 1 Dif fer en tial 8 Temp. 2 Fac tor 01412A T8210A107 5/8" Straight 1 NC 24 VDC HV ½" Straight NC 24 VDC HV ½" Straight NC 120V 60 Hz 110V 50 Hz HV ½" 3, 3S, 4, Straight NC 442 4X, 6, 6P, 24 VDC V HV ½" Straight 3, 3S, 4, NC 60 Hz 4X, 6, 6P, 110V Hz 04895A WPHTX8223-3/8" An gle 3,, 6 NO 24 VDC A3EN HV ½" Straight NO 24 VDC HV ½" 3, 3S, 4, 442 Straight 4X, 6, 6P, NO 24 VDC Foot notes etc., and cleaned, repaired, or replaced as necessary. D. At least an nu ally, the valve di a phragms and seats must be in spected and, if nec es sary, re paired or re placed. WARNING: Close sys tem con trol valve, turn off power supply, and depressurize valve be fore dis as sem - bling valve. It is not nec es sary to re - move the valve from the pipe line to make in spec tions. E. When lu bri cat ing valve com po nents, use a high-grade sil i cone grease (Dow Corning 111 Com pound Lu bri cant or equal). 77 F (25 C) 125 F (52 C) 125 F (52 C) 77 F (25 C) List ings/ap provals 17 (1 207) kpa WWP UL CSA 4 FM NYC 4.0 Yes 3 Yes 11 Yes 3.0 Yes 3, 12 Yes Yes 12 Yes Yes 3 Yes 3.2 Yes 9 Yes 6 Yes Yes 5, 12 Yes Yes 12 Yes 12 En clo sure type: 1 (Gen eral Pur pose) 2 (Drip-Proof), 3 and 3S (Raintight), 4 and 4X (Wa ter tight), 6 and 6P (Sub mers ible), 7 (Ex plo sion- Proof, Class I, Groups A, B, C, and D), 9 (Dust Ig ni tion-proof Class II, Groups E, F, and G) Min i mum Am bi ent Tem per a ture for all valves is 32 F (0 C). Man u fac turer s rec om mended max i mum ambient tem per a tures are de ter mined un der continously en er gized con di tions with max i mum fluid tem per a tures in the valves. Ac tual con di tions (such as nor mally closed and nor mally de-energized with room tem per a ture wa ter in the line) will per mit use at con sid er ably higher am bi ent tem per a tures. UL Listed as Safety Shut-off (UL 429) and Fire Pro tec tion Sepcial Sys tem Wa ter Con trol - Releasing Ser vice (UL 429A - Prod uct Cat e gory VLTR). CSA rec og nized to CSA Stan dards C22.2 No. 0 and No Ex plo sion-proof ver sions are CSA rec og nized to CSA Standards C22.2 Nos. 0, 139, 25, and 30. They are cer ti fied for Haz ard ous Lo ca tions Class I, Groups C and D; Class II, Groups E, F, and G. UL Listed as a gen eral pur pose valve un der UL 429, Elec trically Op er ated Valves. Ex plo sion-proof ver sions are listed for Haz ard ous Lo ca tions Class 1, Groups C and D; Class II, Groups E, F, and G. FM Ap proved as in te gral part of Firecycle II Sys tem. All straight body styles are Red Hat II Models with an over all take-out (end of in let nipple to end of out let nip ple) - 1-1/6 (27mm), ex cept Part Num ber 01412A, which is a Red Hat Model with an over all take-out (end of in let nip ple to end of out let nip ple) = 1-3/4 (44,5mm). All valves have ½ (15mm) NPT con nec tions. Min i mum op er at ing pres sure dif fer en tial is that re quired to open valve and keep it open. The valve will start to close be low the min i mum op er at ing pres sure dif fer en tial. UL Listed for use with Vi king Model A-1 Re lease Con trol Panel. For AC volt ages, in rush current (i.e. to start plunger mov ing) = 28 volt amps. Holding cur rent (i.e. to hold plunger open) = 23 volt amps. FM Ap proved as a com po nent of Vi king 17 (1 207 kpa) elec tri cally re leased De luge, Preaction, and Flow Con trol Sys tems. UL Listed, FM Ap proved and MEA Ac cepted as in te gral part of Firecycle III Sys tem. Ta ble 2
5 January 17, e F. When re as sem bling, tighten parts to torque val ues in di cated in ASCO s main te nance in struc tions (packed with valve). G. Af ter main te nance is com pleted, op er - ate the valve a few times to be sure of proper op er a tion. A me tal lic click sig - ni fies the so le noid is op er at ing. H. It is rec om mended that the valve be re - placed at seven-year in ter vals. Shorter in ter vals may be re quired if the valve is sub ject to cor ro sive wa ter sup plies or at mo spheres. I. All service must be performed by qual i - fied per son nel. Upon completion of inspections or replacement of the valve, the entire system must be checked for proper operation. See appropriate system description and testing instructions for additional information. 10. INSTALLATION A. Check name plate for cor rect unit, in - clud ing volt age and mode of op er a tion. Fol low all in stal la tion and main te nance in struc tions en closed with the valve. B. Stan dard so le noids may be mounted in any po si tion. How ever, for op ti mum life and per for mance, so le noids should be mounted ver ti cally and up right with the coil up right. Ex plo sion-proof so le noids must have the coil up right. C. A 50 mesh strainer is re quired at the prim ing line con nec tion on the in let side of the valve. This strainer is in - cluded as part of the Model E-1 De luge Valve Trim. In stall the strainer as indi - cated on Vi king s trim draw ing. Install the so le noid ac cord ing to mark ings on the valve body. Ap ply pipe-joint com - pound spar ingly to male pipe threads only. If ap plied to valve threads, it may en ter the valve and cause op er a tion dif - fi culty or leak age. Also, avoid putt ing pipe com pound on first two male threads. D. The unit must be wired in accordance with lo cal and national elec tri cal codes. For valves equipped with explosion-proof and water tight enclosures, the electrical fittings must be approved for use in the hazardous location. E. Upon completing the installation, the entire system must be tested for proper operation. See system description and testing instructions for additional information.
OBSOLETE DESIGN DATA PREACTION FOAM/WATER SYSTEM USING AFFF OR ARC. March 1, Foam 30a
March 1, 2001 Foam 30a 1. DESCRIPTION A Preaction Blad der Tank Foam/Wa ter Sys tem is a stan dard preaction sys tem ca pa ble of dis charg ing a foam/wa ter so lu tion au to mat i cally through any sprin
More information796+<*; 4(5<(3 240 S 24 +,3;(
240 S 24 240 S 24 DELTA ELEKTRONIKA BV Safety Instructions Caution The following safety precautions must be observed during all phases of operation, service and repair of this equipment. Failure to comply
More information796+<*; 4(5<(3 ES ,3;(
ES 030-10 ES030-10 DELTA ELEKTRONIKA BV Safety Instructions Caution The following safety precautions must be observed during all phases of operation, service and repair of this equipment. Failure to comply
More informationSX - se ries 150 SX 75-75
SX - se ries 15 SX 75-75 15SX75-75 DETA EEKTRONIKA BV Safety Instructions Caution The following safety precautions must be observed during all phases of operation, service and repair of this equipment.
More informationTargeted en gi ne e ring de sign. Hedge and Grasscutter mowers
Targeted en gi ne e ring de sign Hedge and Grasscutter mowers Fi xed di spla ce ment axial pi ston pump and mo tor swash plate design for open cir cu it One of Casappa s aims is to produce targeted engineering
More informationMODELS CA-1 & CA-2 MODEL CA-1 CA-TB TECHNICAL BULLETIN BACK PRESSURE / RELIEF REGULATOR FEATURES APPLICATIONS CAUTION
ISO Registered Company MODELS CA-1 & CA-2 TECHNICAL BULLETIN CA-TB 02-16 MODEL CA-1 BACK PRESSURE / RELIEF REGULATOR The Model CA-1 is a compact, forged Bronze body or SST barstock body back pressure regulator
More information796+<*; 4(5<(3 600 S 24 +,3;(
600 S 24 600S24 DELTA ELEKTRONIKA BV Safety Instructions Caution The following safety precautions must be observed during all phases of operation, service and repair of this equipment. Failure to comply
More informationS 280 S 6-40 S S 28-10
S 280 S 6-40 S 15-18 S 28-10 S280 - S 6-40 S 15-18 S 28-10 Safety Instructions Caution The following safety precautions must be observed during all phases of operation, service and repair of this equipment.
More informationPre-installation Manual. PlateWriter 3600 Pro
Pre-installation Manual PlateWriter 3600 Pro Pre-installation Manual PlateWriter 3600 Pro T11435 Edition AB, March 2016 This book has part No 10081552 0-2 This man ual is pub lished by: GLUNZ & JENSEN
More informationTECHNICAL DATA TRIMPAC MODEL B-4, B-4B & B-4S SINGLE INTERLOCK PREACTION SYSTEM WITH PNEUMATIC RELEASE
Page 1 of 20 1. DESCRIPTION TRIMPAC Model B-4, B-4B & B-4S is a factory assembled trim package for a single interlocked preaction system with a pneumatic release module in a metal enclosure. The standard
More informationSM3300-se ries. Firm ware Up date SM SM 66-AR-110 SM 100-AR-75 SM 330-AR-22 SM 660-AR-11
DELTA ELEKTRONIKA B.V. DC POWER SUPPLIES Vissersdijk 4, 4301 ND Zierikzee, the Netherlands www.deltapowersupplies.com Tel. +31 111 413656 SM3300-se ries SM 18-220 SM 66-AR-110 SM 100-AR-75 SM 330-AR-22
More informationTECHNICAL DATA. Inlet Type Outlet Type OBSOLETE 6 (DN150)
January 13, 2006 Deluge Valves 211 a 1. PRODUCT NAME Viking Model E-1 Deluge Valve 3 (DN80) Available since 1985 4 (DN100) Available since 1985 6 (DN150) Available since 1984 2. MANUFACTURER THE VIKING
More informationTECHNICAL DATA. Trimpac 244a. April 15, 2011
April 15, 2011 Trimpac 244a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-1 and B-1B is a factory-assembled trim package with an electric release module in a metal enclosure. The standard trim normally required
More informationYCAS AIR-COOLED LIQUID CHILLERS YCAS0373 THROUGH YCAS0653 STYLE G (R22) (50 Hz)
AIR-COOLED SCREW LIQUID CHILLERS WIRING DIAGRAM New Release Form 201.19-W3 (1104) YCAS AIR-COOLED LIQUID CHILLERS YCAS0373 THROUGH YCAS0653 STYLE G (R22) (50 Hz) TABLE OF CONTENTS PAGE NOMENCLATURE...
More informationMODELS 1171 AND 2171
INSTALLATION, OPERATION & MAINTENANCE MANUAL (IOM) IOM-111/211 10/ MODELS 111 AND 211 BACK PRESSURE / RELIEF REGULATORS SECTION I I. DESCRIPTION AND SCOPE Models 111 and 211 are back pressure/relief regulators
More informationTECHNICAL DATA. Trimpac 249a. September 16, 2013
September 16, 2013 Trimpac 249a 1. DESCrIpTION DESCRIPTION TRIMPAC Model B-4, B-4B & B-4S is a factory assembled trim package for a single interlocked with a pneumatic release module in a metal enclosure.
More informationVisible Break Load break switches can in cor po rate a visible break of all three phases.
G E N E R A L F E A T U R E S Since 1905, G&W has provided custom power solutions to utilities and electric power users around the world. G&W has a wide selection of reliable, quality switching and fault
More informationHAZARDOUS LOCATION SUBMERSIBLE PUMP Model S4NVX (Class I, Division 1, Group C & D): FM
Installation and Service Manual HAZARDOUS LOCATION SUBMERSIBLE PUMP Model S4NVX (Class I, Division 1, Group C & D): FM NOTE! To the installer: Please make sure you provide this manual to the owner of the
More informationINSTALLATION, OPERATION & MAINTENANCE MANUAL (IOM) MODEL HP-1+6+S HIGH PRESSURE DIFFERENTIAL REDUCING REG U LA TOR SECTION I SECTION II
I. DESCRIPTION AND SCOPE The Model HP-1+6+S is a heavy duty, high pressure differential reducing regulator used to control differential pressure between downstream outlet (P 2 ) pressure and a loading
More informationTECHNICAL DATA. Q= C v P S
1 of 9 1. DESCRIPTION The Viking Model E-1 Deluge Valve is a quick-opening, differential diaphragm, flood valve with one moving part. The deluge valve is used to control water flow in deluge and preaction
More informationMODEL PRESSURE REDUCING REGULATOR BODY SIZES 1/4" OR 3/8" (DN8 or DN10) TECHNICAL BULLETIN 3381-TB FEATURES APPLICATIONS
TECHNICAL BULLETIN 3381-TB 05-12 MODEL 3381 PRESSURE REDUCING REGULATOR BODY SIZES 1/4" OR 3/8" (DN8 or DN10) The Model 3381 is an inexpensive, bronze pressure reducing regulator designed to handle small
More informationMODEL 2171 CAUTION TECHNICAL BULLETIN BACK PRESSURE / RELIEF REGULATOR FEATURES APPLICATIONS. ISO Registered Company
TECHNICAL BULLETIN 2172mo 02-16 ISO Registered Company MODEL 2171 BACK PRESSURE / RELIEF REGULATOR The Model 2171 is a stainless steel back pres sure/re lief reg u la tor designed to handle small to mid-ca
More informationAviStart 2501 Owner's Manual
I WARNING I! Always exercise caution and common sense when operating your AviStart system.! This product is intended for vehicles with fuel-injection and automatic transmissions only. NEVER attempt to
More informationTECHNICAL DATA 1-1/2 (dn40)
July 1, 2011 Deluge Valves 209a DESCRIPTION The Viking Model E-3 1-1/2 Deluge Valve is a quick-opening, differential type flood valve with a rolling diaphragm clapper. The deluge valve is used to control
More informationSM se ries SM SM SM 70 - AR - 24 SM AR - 4
SM 800 - se ries SM 7.5-80 SM 18-50 SM 70 - AR - 24 SM 400 - AR - 4 Safety Instructions Caution The following safety precautions must be observed during all phases of operation, service and repair of this
More informationTECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)
1 of 9 1. DESCRIPTION The Viking 2 (DN50) is a quick-opening, differential diaphragm, flood valve with one moving part. The deluge valve is used to control water flow in deluge and preaction sprinkler
More informationSUBMERSIBLE SEWAGE PUMP RECESSED IMPELLER
Installation and Service Manual SUBMERSIBLE SEWAGE PUMP RECESSED IMPELLER Model S3HRC NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible
More informationOWNER S MANUAL. ZOELLER HAZARDOUS ENVIRONMENT PUMPS (For Class 1, Division 1, Groups C & D Applications) Explosion Proof Motors
NOTICE TO INSTALLER: Instructions must remain with installation. Product information presented here re fl ects con di tions at time of publication. Consult factory re gard ing dis crep an cies or in con
More informationES150 - se ries. 150 watts DC POWER SUP PLIES. ES V 0-10 A ES V 0-5 A ES V 0-2 A ES V ma
P.O. BOX 27 4300 AA ZIERIKZEE NETH ER LANDS TEL. +31 111 413656 FAX +31 111 416919 www.deltapowersupplies.com ES150 - se ries 150 watts DC POWER SUP PLIES ES 015-10 0-15 V 0-10 A ES 030-5 0-30 V 0-5 A
More informationInstructions for Installation, Operation, Care and Maintenance
Model H Deluge Riser Assembly Bulletin 507 Rev.C Bulletin 507 Rev.C Instructions for Installation, Operation, Care and Maintenance 1 1 2 (40mm) Size Electric Actuation The Reliable Automatic Sprinkler
More informationMODEL 964. PNEUMATIC CONTROL VALVE 1/2" - 2" Size w/c27 or C53 Actuator TECHNICAL BULLETIN 964-TB FEATURES APPLICATIONS. ISO Registered Company
TECHNICAL BULLETIN 02-16 ISO Registered Company MODEL 964 PNEUMATIC CONTROL VALVE 1/2" - 2" Size w/ or Actuator The Model 964 is a globe-style, pneumatic control valve for general plant utility services.
More informationS3HVX Explosion-Proof Submersible Pump
Pump Installation and Service Manual S3HVX Explosion-Proof Submersible Pump (Class I, Division 1, Group D): UL (Class I, Division 1, Groups C & D): FM NOTE! To the installer: Please make sure you provide
More informationOwner s Manual SET-UP OPERATION MAINTENANCE. IMPORTANT: Read Safety Rules and Instructions Carefully OG-4905 PRINTED IN CANADA
Owner s Manual SET-UP OPERATION MAINTENANCE IMPORTANT: Read Safety Rules and Instructions Carefully PRINTED IN CANADA OG-4905 CALLING CUS TOMER SUP PORT LO CATE YOUR MODEL NUMBER AND SE RIAL NUMBER which
More informationQ= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications
1 of 9 1. DESCRIPTION The Viking Flow Control Valve is a quick opening, differential diaphragm flood valve with a spring loaded floating clapper. The Flow Control Valve can be used to facilitate manual
More informationMODEL 1000HP-5 and MODEL 1000HP-36
TECHNICAL BULLETIN 1000HP-CRYO-TB 02-16 ISO Registered Company MODEL 1000HP-5 and MODEL 1000HP-36 CRYOGENIC PRESSURE REDUCING REGULATORS Model 1000HP-5 and 1000HP-36 are cryogenic re duc ing regulators
More informationMODEL 964. PNEUMATIC CONTROL VALVE 2" & 3" Size w/110 Actuator TECHNICAL BULLETIN 964-2"& 3" TB No Rev E, due to the C110 Actuator Series
TECHNICAL BULLETIN 964-2"& 3" TB 02-16 ISO Registered Company No Rev E, due to the C Actuator Series MODEL 964 PNEUMATIC CONTROL VALVE 2" & 3" Size w/ Actuator The Model 964 is a globe-style, pneumatic
More informationON-SITE WASTEWATER PROD UCTS
NOTICE TO INSTALLER: Instructions must remain with installation. FW114 87 Supesedes NEW Product information presented here re fl ects con di tions at time of publication. Consult factory regarding discrepancies
More informationSM6000-se ries SM SM SM SM SM SM SM SM
DELTA ELEKTRONIKA B.V. DC POWER SUPPLIES Vissersdijk 4, 4301 ND Zierikzee, the Netherlands www.deltapowersupplies.com Tel. +31 111 413656 SM6000-se ries SM 15-400 SM 30-200 SM 45-140 SM 60-100 SM 70-90
More informationTECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)
Flow Control 500a DESCRIPTION The Viking 1-1/2 is a quick opening, differential type flood valve with a spring loaded rolling diaphragm clapper. The can be used to facilitate manual or automatic on/off
More informationTECHNICAL DATA CAUTION
Page 1 of 6 1. DESCRIPTION The Viking Model D-2 Accelerator is a quick-opening device, with an integral anti-flood assembly, used to increase the operating speed of a differential type dry pipe valve.
More informationSTANDARD / GENERAL SPECIFICATIONS
TECHNICAL BULLETIN 123-S-DIFF-TB 02-16 ISO Registered Company MODEL 123-1+6+S HIGH PRESSURE VERSION DIFFERENTIAL BACK PRESSURE RELIEF REGULATOR Model 123-1+6+S is a high pressure variation of the basic
More informationTECHNICAL DATA CONCENTRATE CONTROL VALVE APPLICATIONS, PRIMING CONNECTIONS, AND TRIMS 1. GENERAL DESCRIPTION 2. LISTINGS AND APPROVALS.
Page 1 of Telephone: 29-95-9501 Technical Services: 877-38-5 Fax: 29-818-180 Email: techsvcs@vikingcorp.com 1. GENERAL DESCRIPTION The Halar Coated Concentrate Control (CCV) is utilized in Viking foam
More information1,000 LB. CAPACITY TELESCOPIC TRANSMISSION JACK WITH AIR PUMP
QTJ01A 1,000 LB. CAPACITY TELESCOPIC TRANSMISSION JACK WITH AIR PUMP Address: 200 Cabel St. Louisville, KY 40206. Sales and Service: 1-877-771-5438. Fax: 502-583-5488. Website: www.qualitylifts.com SPECIFICATIONS
More informationHAZARDOUS LOCATION SUBMERSIBLE GRINDER PUMP
Installation and Service Manual HAZARDOUS LOCATION SUBMERSIBLE GRINDER PUMP Model HPGX200 (Class I, Division 1, Groups C & D): FM NOTE! To the installer: Please make sure you provide this manual to the
More informationMODEL S DIFFERENTIAL
ISO Registered Company MODEL 123-1+6+S DIFFERENTIAL BACK PRESSURE / RELIEF REGULATOR I. DESCRIPTION AND SCOPE INSTALLATION, OPERATION & MAIN TE NANCE MANUAL (IOM) SECTION I IOM-123 1+6+S DIFF 02-16 The
More informationDEVELOPMENT OF DIELECTRIC SENSOR TO MONITOR THE ENGINE LUBRICATING OIL DEGRADATION
S1061 DEVELOPMENT OF DIELECTRIC SENSOR TO MONITOR THE ENGINE LUBRICATING OIL DEGRADATION by Vasanthan BALASHANMUGAM * and Devaradjane GOBALAKICHENIN Department of Automobile Engineering, Anna University,
More informationMODELS D and DL PRESSURE REDUCING REGULATORS
ISO Registered Company I. DESCRIPTION AND SCOPE INSTALLATION, OPERATION & MAINTENANCE MANUAL (IOM) MODELS D and DL PRESSURE REDUCING REGULATORS SECTION I IOM-D/DL 02-16 The Model D is a pressure reducing
More informationCOYOTE. Retrofit Closure. Refinement of the Breed. COYOTE Retrofit Closure. The ideal Closure for replacement or expansion 1-29
COYOTE Retrofit Closure COYOTE Closure Series: Section 1 Refinement of the Breed The ideal Closure for replacement or expansion The COYOTE Retrofi t Closure contains a ver sa tile Fiber Management System
More information! NEVER attempt to remote start the engine while the vehicle is in an enclosed area without sufficient ventilation.
FRONT COVER I WARNING I! Always exercise caution and common sense when operating your AviStart system.! This product is intended for vehicles with fuel-injection and automatic transmissions only. NEVER
More informationSM3000-se ries SM D SM D SM D SM D SM D SM D
DELTA ELEKTRONIKA B.V. DC POWER SUPPLIES Vissersdijk 4, 4301 ND Zierikzee, the Netherlands www.deltapowersupplies.com Tel. +31 111 413656 SM3000-se ries SM 15-200 D SM 30-100 D SM 45-70 D SM 70-45 D SM
More informationINSTALLATION, OPERATION & MAINTENANCE MANUAL (IOM) MODEL B7 BACK PRESSURE REGULATOR. SECTION l
INSTALLATION, OPERATION & MAINTENANCE MANUAL (IOM) IOM-B7 03/16 ISO Registered Company MODEL B7 BACK PRESSURE REGULATOR I. DESCRIPTION AND SCOPE The Model B7 is a back pressure regulator used to control
More informationSection 5 FIBERLIGN Hardware for OPGW
FIBERLIGN Hardware for OPGW: Section Section FIBERLIGN Hardware for OPGW Table of Contents Page Fiber Optic Product Layout for OPGW...-2 FIBERLIGN Dead-end for OPGW...-3 FIBERLIGN Formed Wire Dead-end...-6
More informationNon-Ventilated Automation Transformers 6
Non-Ventilated Automation Transformers 6 Automation Transformers - Non-Ventilated 50 VA to 45 SolaHD encapsulated transformers are rated for Hazardous Locations (Class 1, Division 2, Group A-D) as well
More information4 qwer. Steam and Hot Water Valves 2/2 SERIES. Hot Water/ Steam. Features. Construction. Nominal Ambient Temperature Ranges: Electrical.
qwer Normally Closed or Normally Open and Hot Water Valves Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT NC NO 2/2 SERIES Features Handle the challenges of high-temperature fluids. PTFE and EPDM discs,
More informationInstructions for Installation, Operation, Care and Maintenance
Model H Deluge Riser Assembly Bulletin 507 Rev. D Bulletin 507 Rev. D Instructions for Installation, Operation, Care and Maintenance 1 1 / 2 (40mm) Size Electric Actuation The Reliable Automatic Sprinkler
More informationLow Voltage Network Quality Power factor correction Harmonic fl ickering Dynamic fl icker compensation
Power factor correction Harmonic fl ickering Dynamic fl icker compensation Products & Systems.1 ABB Inc. 888-385-1221 www.abb-control.com AC 1000-11/03 Spec Tech Industrial 203 Vest Ave. Valley Park, MO
More informationBY SPORTS TUTOR OWNER S MANUAL
Introduction This manual con tains im por tant in for ma tion con cern ing the pro per use and care of your Sports Tutor Pickleball ball machine. Please read completely before operating your Pickleball
More informationMODEL SCV-30 SCV-30-TB TECHNICAL BULLETIN SANITARY GLOBE-STYLE CONTROL VALVES FEATURES APPLICATIONS. ISO Registered Company
TECHNICAL BULLETIN SCV-30-TB 03-17 ISO Registered Company MODEL SCV-30 SANITARY GLOBE-STYLE CONTROL VALVES The Model SCV-30 * is a revolutionary, throttling, pneumat i cal ly actuated control valve. This
More informationNEW CONCEPT OF ELECTRICAL DRIVES FOR PAPER AND BOARD MACHINES BASED ON ENERGY EFFICIENCY PRINCIPLES
NEW CONCEPT OF ELECTRICAL DRIVES FOR PAPER AND BOARD MACHINES BASED ON ENERGY EFFICIENCY PRINCIPLES by Borislav JEFTENI], Saša ŠTATKI], Milan BEBI], and Leposava RISTI] Original scientific paper UDC: 676.026.23/.25
More informationG2HX Explosion-Proof Submersible Grinder Pumps
Pump Installation and Service Manual G2HX Explosion-Proof Submersible Grinder Pumps (Class 1, Division 1, Groups C & D): FM NOTE! To the installer: Please make sure you provide this manual to the owner
More informationCombiTemp Temperature Measuring System
CombiTemp Temperature Measuring System Housing DIN-B Standard or Ex ia safety DIN-B Ex n safety Ø80 mm stainless steel Transmitters FlexTop 2201 FlexTop 2211 FlexTop 2221 FlexTop 2231 Displays The process
More informationMODEL 4381 PRESSURE REDUCING REGULATOR 1/4, 3/8, or 1/2 (DN8, DN10, or DN15) Sizes
TECHNICAL BULLETIN 4381-TB 03-16 ISO Registered Company MODEL 4381 PRESSURE REDUCING REGULATOR 1/4, 3/8, or 1/2 (DN8, DN10, or DN15) Sizes The Model 4381 is a stainless steel pressure reducing regu la
More information2/2 ^ % ) Normally Closed or Normally Open Hot Water and Steam Valves. Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT
Normally Closed or Normally Open Hot Water and Valves Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT 2/2 Features Handle the challenges of high-temperature fluids PTFE and EPDM discs, stainless steel
More informationTABLE OF CONTENTS. MODEL UBH Tube Axial Belt Drive Upblast Roof Exhauster
TABLE OF CONTENTS Page Construction Features ---------------------------------------------------------3 High Temperature and Smoke Exhaust Application -------------------------------------4 Performance
More informationPackage Unit Modulating Economizer Installation Instructions
Package Unit Modulating Economizer Installation Instructions Downflow Unit Warning: Recognize this symbol as an indication of Important Safety Information! Read all instructions prior to installation.
More informationTotalPac 3 Deluge, Electric release Remote controlled system
(Optional) DESCRIPTION This TOTALPAC 3 integrated fire protection system by FireFlex Systems Inc. consists of a deluge system trim totally preassembled, pre-wired and factory tested. All electrical and
More informationENERGY AUDIT AND CONSERVATION POTENTIAL ANALYSIS OF A LARGE COMPREHENSIVE COMMERCIAL BUILDING
S567 ENERGY AUDIT AND CONSERVATION POTENTIAL ANALYSIS OF A LARGE COMPREHENSIVE COMMERCIAL BUILDING by Chunzhi ZHANG, Nianxia YUAN, and Qianjun MAO * School of Ur ban Con struc tion, Wuhan Uni ver sity
More informationMODELS CA-1 & CA-2 MODEL CA-1 CA-TB TECHNICAL BULLETIN BACK PRESSURE / RELIEF REGULATOR FEATURES APPLICATIONS CAUTION
MODELS CA-1 & CA-2 TECHNICAL BULLETIN CA-TB 03-11 MODEL CA-1 BACK PRESSURE / RELIEF REGULATOR The Model CA-1 is a compact, forged bronze body back pressure regulator used to control inlet pressure level
More informationMODELS S4LX, S4BX, S4KX, S4QX, H4QX, S4LVX, S6AX, S6LX and S8FX
SLX MODELS SLX, SBX, SKX, SQX, HQX, SLVX, SAX, SLX and SFX (Class I, Division, Groups C & D): FM HAZARDOUS LOCATION SUBMERSIBLE PUMP INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make
More informationMODEL 31 N LOW PRESSURE REDUCING SERVICE REGULATOR TECHNICAL BULLETIN FEATURES CAUTION
TECHNICAL BULLETIN 31-N-TB 02-16 ISO Registered Company MODEL 31 N LOW PRESSURE REDUCING SERVICE REGULATOR The Model 31-N is a compact service regulator designed expressly for use in the process in dus
More informationVisible Break Load break switches can in cor po rate a visible break of all three phases.
G E N E R A L F E A T U R E S Since 1905, G&W has provided custom power solutions to utilities and electric power users around the world. G&W has a wide selection of reliable, quality switching and fault
More informationTECHNICAL DATA OBSOLETE
August 31, 2006 Check Valve 815a 1. PRODUCT NAME Viking Easy Riser Swing Check Valve Model E-1: Available since 1992 Model F-1: Available since 1994 2. MANUFACTURER The Viking Corporation 210 N. Industrial
More informationTotalPac 3 Firecyle III Wet pipe Remote controlled system
(Optional) DESCRIPTION This TOTALPAC 3 integrated fire protection system by FireFlex Systems Inc. consists of a Firecycle III system trim totally preassembled, pre-wired and factory tested. All electrical
More informationINSTALLATION, OPERATION & MAIN TE NANCE MANUAL (IOM) MODEL 123 BASIC BACK PRESSURE / RELIEF REGULATOR SECTION I
INSTALLATION, OPERATION & MAIN TE NANCE MANUAL (IOM) 11-16 ISO Registered Company MODEL 123 BASIC BACK PRESSURE / RELIEF REGULATOR SECTION I I. DESCRIPTION AND SCOPE The Model 123 is a back pressure relief
More informationAuto mo tive Cor po ra tion TC 237 TRANSFER CASE PARTS MAN UAL. Fabco Automotive Corporation, Livermore, CA
Auto mo tive Cor po ra tion TC 237 TRANSFER CASE PARTS MAN UAL Fabco Automotive Corporation, Livermore, CA See Note 5 See Note 6 See Note 1 See Note 3 See Note 4 See Note 2 SERVICE PARTS LIST TRANS FER
More informationPERFORMANCE, EMISSION, AND COMBUSTION CHARACTERISTICS OF A CI ENGINE USING LIQUID PETROLEUM GAS AND NEEM OIL IN DUAL FUEL MODE
THERMAL SCIENCE: Year 2010, Vol. 14, No. 4, pp. 923-935 923 PERFORMANCE, EMISSION, AND COMBUSTION CHARACTERISTICS OF A CI ENGINE USING LIQUID PETROLEUM GAS AND NEEM OIL IN DUAL FUEL MODE by Palanimuthu
More information4 qwer 2/2. Pilot Operated General Service Solenoid Valves. Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT. Features. Construction.
4 qwer Pilot Operated General Service Solenoid Valves Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT NC NO 2/2 SERIES Features Wide range of pressure ratings, sizes, and resilient materials provide
More information32-055A/80-055/SE2030In stall/193 1
SE 2O3O Standard Features FACT FalseA larm Control and Test An ex clu sive and pat ented Clif ford in no va tion that ab so lutely, posi tively puts an end to re cur ring false alarms. Here's how it works:
More informationTECHNICAL DATA. Q= C v P S FLOW CONTROL VALVE MODEL J-2 HALAR COATED 1-1/2 & 2 (DN40 & DN50) 1. DESCRIPTION
Page 1 of 9 1. DESCRIPTION The Viking Flow Control Valve is a quick opening, differential diaphragm flood valve with a spring loaded floating clapper. The Flow Control Valve can be used to facilitate manual
More informationPILOT S OPERATING HANDBOOK AND FAA APPROVED AIRPLANE FLIGHT MANUAL MOONEY M20S
PILOT S OPERATING HANDBOOK AND FAA APPROVED AIRPLANE FLIGHT MANUAL MOONEY THIS HANDBOOK IN CLUDES THE MA TE RIAL RE QUIRED TO BE FUR NISHED TO THE PI LOT BY THE FED ERAL AVIA TION REGU LA TIONS, AND CON
More informationINDUSTRIAL CONTROL INSTRUMENTS FOR PROCESS AUTOMATION
REFRIGERATION AND AIR CONDITIONING Pressure controls, differential controls Type RT Contents Page Introduction...................................................................................... 3 Features..........................................................................................
More informationCHERMACK MACHINE, INC.
CHERMACK MACHINE, INC. CUSTOM BUILT TRACKS Chermack Machine, Inc. 1869 13 ½ Avenue Cameron, WI 54822 Phone: (715) 458-2655 Fax: (715) 458-2657 Web Site: www.chermackmachine.com September 30, 2005 Printed
More informationPolyshot Heated Sprue Bushings
Polyshot Heated Sprue Bushings Machine Nozzle Sealing Radius Hard Tool Steel Body All Wiring Runs Through Top Clamp Plate Stainless Steel Replaceable Collar Flow Path Independent Thermocouple Profiled/Tapered
More informationDV-5 Deluge Valve Aluminium Bronze Diaphragm Style General Description
Worldwide Contacts www.tyco-fire.com DV-5 Deluge Valve Aluminium Bronze Diaphragm Style General Description The TYCO Aluminum Bronze DV-5 Deluge Valves are available to provide an alternative material
More informationMODEL DA0 DO-ALL SERIES IVP PRESSURE REDUCING REGULATORS SMALL PISTON, PILOT-OPERATED DA0-TB TECHNICAL BULLETIN FEATURES APPLICATIONS
TECHNICAL BULLETIN DA0-TB 09-12 MODEL DA0 DO- SERIES IVP PRESSURE REDUCING REGULATORS SM PISTON, PILOT-OPERATED Model DA0 is a pilot-operated steam reducing regulator with a piston design. The internal
More informationVentilated Distribution Transformers
Ventilated Distribution Transformers The Energy Policy Act of 2005 (H.R. 6) requires Distribution Transformers manufactured after January 1, 2007 to meet specifi c energy effi ciency requirements. EPAct
More informationPressure controls, differential pressure controls Type RT REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Pressure controls, differential controls Type RT REFRIGERATION AND AIR CONDITIONING Technical leaflet Technical data Pressure controls, differential controls, type RT Contents Page Introduction......................................................................................
More informationVisible Break Load break switches can in cor po rate a visible break of all three phases.
G E N E R A L F E A T U R E S Since 1905, G&W has provided custom power solutions to utilities and electric power users around the world. G&W has a wide selection of reliable, quality switching and fault
More informationS4 N 250 B W - 2 xxx. Isomax. Isomax Molded case circuit breakers S3 S8. MCCBs
Molded case circuit breakers S3 S8 S4 N 250 B W - 2 xxx Accessories (added in alpha-numeric order) 1 A = Auxiliary Switch BA = Bell Alarm BA3 = Bell Alarm (S6/S7 only) S_ = Shunt trip with voltage code
More informationMODEL C-CS CLEAN STEAM PRESSURE REDUCING REGULATOR C-CS-TB TECHNICAL BULLETIN FEATURES APPLICATIONS. ISO Registered Company MODEL C-CS
TECHNICAL BULLETIN 05-17 ISO Registered Company MODEL C-CS CLEAN STEAM PRESSURE REDUCING REGULATOR The Model C-CS* is a 316L SST self-contained pressure re ducing regulator designed primarily for steam
More informationMODEL 123 BACK PRESSURE / RELIEF REG U LA TOR CAUTION TECHNICAL BULLETIN 123-TB FEATURES MODEL 123 APPLICATIONS
TECHNICAL BULLETIN 123-TB 02-16 ISO Registered Company MODEL 123 BACK PRESSURE / RELIEF REG U LA TOR The Model 123 is a relief regulator suitable as a back pressure regulator or bypass valve for controlling
More informationS4 N 250 B W - 2 xxx. Isomax MCCBs. Isomax Molded case circuit breakers S1 S8
Molded case circuit breakers S1 S8 S4 N 250 B W - 2 xxx Accessories (added in alpha-numeric order) 1 A = Auxiliary Switch BA = Bell Alarm BA3 = Bell Alarm (S6/S7 only) S_ = Shunt trip with voltage code
More informationLXIPEB33 505,038M MARCH 14, 2012 SUPERCEDES
ENERGENCE & L SE RIES KITS AND AC CES SO RIES LXIPEB33 505,038M MARCH 14, 2012 SUPERCEDES 07-07-10 LAPEB 30/36 LAPEV 30/36 IN STAL LA TION IN STRUC TIONS FOR HIGH STATIC POWER EXHAUST FAN (PEB) AND HIGH
More informationTECHNICAL BULLETIN. Design Con cept: Two Body Configurations: Multiple Ports: Characteristic: Dual Stem Seal: Polished In te ri or: Exterior Finish:
TECHNICAL BULLETIN SCV-S-TB 03-17 ISO Registered Company MODEL SCV-S SANITARY GLOBE-STYLE CONTROL VALVES The Model SCV-S is a throttling, pneumatically ac tu at ed control valve. This design provides a
More informationHOLOPHANE Outdoor Lighting
68 Sign Lighting Signs have two purposesto attract attention and to convey a message. And during nighttime hours, sign lighting must provide visibility and legibility to deliver the appropriate message.
More informationMANUAL OPERATION. Se rial Num ber NZ and af ter. Die sel Gas o line Bat tery Electric Bi-En ergy Options
MHP14AT MHP13AT Die sel Gas o line Bat tery Electric Bi-En ergy Options Se rial Num ber NZ110108 and af ter OPERATION MANUAL Part Num ber 13618-1 August 2011 (Rev A) LIMITED WARRANTY Snorkel warrants each
More informationQ= C v P S. Flow control valve Model j-2 Halar coated
October 22, 2010 Flow Control 507a 1. DESCRIPTION The Viking Flow Control Valve is a quick opening, differential diaphragm flood valve with a spring loaded floating clapper. The Flow Control Valve can
More informationModel DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation
Deluge Valve DV-5 Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation GeneralDescription The Model DV-5 Deluge Valve (described in Technical
More informationInstallation and Service Manual JB-1 System Sewage Ejector Pump Package
Installation and Service Manual JB-1 System Sewage Ejector Pump Package NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party
More informationYCAL0014E_ - YCAL0124E_ R-22 & HFC-407C STYLE C (60 Hz)
AIR-COOLED LIQUID CHILLERS HERMETIC SCROLL WIRING DIAGRAM New Release Form 150.62-W6 (303) YCAL0014E_ - YCAL0124E_ R-22 & HFC-407C STYLE C (60 Hz) 29224(R)A 200-3-60 230-3-60 380-3-60 460-3-60 575-3-60
More information