Automatic Entrance Systems

Size: px
Start display at page:

Download "Automatic Entrance Systems"

Transcription

1 ON NIGHT ONE W A Y HOLD OPEN FULL OPEN UCED OPEN 890 Microprocessor Controller Power Connector ( pin) Main Harness Connector ( pin) Motor Connector ( pin) CAUTION Fuse Inside. Adjustments to the door can only be made with a Handy Terminal. Rating: V, A No adjustments are available inside the control box. Size:. x 0mm. Replaceable fuse located inside the control box. WARNING. Turn the power off prior to removing the cover.. This unit can not be repaired in the field. Any attempted repairs by an unauthorized facility will void the warranty. Handy Terminal Connector ( pin) Automatic Entrance Systems ELECTRICAL INSTALLATION MANUAL **SLIDERS** SERVICE GROUND 0 VAC "COMMON" 0 VAC "HOT" MINIMUM AMPERE SERVICE PER OPERATOR OPERATOR SWITCH BOX MOTOR DETECTOR EMITTER MOTOR HARNESS AND PLUGS NO.COLOR NO.COLORUSE Whi NotUsed MotorVPhase VAComon EncoderVDC VACHot te EncoderAPhase MotorUPhase EncoderGround EncoderBPhase USE 9DCV 7 Whi VDC+ VDC-(Comon) InteriorActivationSensor HoldingBeam ucedopening NO.SYMBOLCOLORUSE[SLIDEMODESELECTED]USE[SWINGMODESELECTED] 7890 BHM0 M SQ BA OUT+OUT- ModeSwi ExteriorActivationSensor AlternatingActivation BreakoutOutputSwi tegrenviolet (SeModeSwi tch tch tchhi(elec.lock,airlock,etc.) tchlo(elec.lock,airlock,etc.) tchtable) VDC+ VDC-(Comon) AproachActivationSensor No. HoldingBeamorSwingSensor ThresholdSafetyMa ModeSwi ExteriorActivationSensor AlternatingActivation BreakoutOutputSwi (SeModeSwi tch tchtable) MODESWITCHTABLE tch tchhi(elec.lock,airlock,etc.) Forcontinuedprotection againstfire,replaceonly withafuseofthesame typeandrating. OpenGndGndOpen OpenOpenGndGndModeAutoExitHoldOpenNight M t tchlo(elec.lock,airlock,etc.) YELLOW GRAY VIOLET NOT USED NOT USED NOT USED LIGHT "UCE" LEAVE OPEN Teleco Brand Safety Beams PLUG FOR HANDY TERMINAL NOT USED O F F O N L Y D O O R O PE RA T IO N ROCKER SWITCH EXTENSION HARNESS PT. 98 YELLOW PLUG WITH JUMPER MUST BE IN PLACE YELLOW PLUG WITH JUMPER MUST BE IN PLACE A U T O ACUSENSOR HARNESS PT. NO. 98 ACUSENSOR HARNESS PT. NO. 98 INTERIOR ACUSENSOR PT. NO. 890 EXTERIOR ACUSENSOR PT. NO. 890 BACK SIDE OF SWITCH SHOWN. WARNING Do not install, operate or service this product unless you have read and understand the Safety Practices, Warnings, Installation and Operating Instructions contained in this manual. Failure to do so may result in property damage, or bodily injury. ENTRANCES INC. Phone: Fax: Technical Assistance: CustomerService@NabcoEntrances.com 09 Revision -8-0

2 Table of Contents Electrical Information Page Typical Slider Wiring Page Microprocessor Controller Page - Dual Operator Wiring Diagrams Page 7 Acusensor/Acumotion Page 8 How Door Function Modes are Achieved via the Rocker Switches Page 9 Holding Beams (Activation Hold Open) Page 0 Holding Beam (Breakout Power Interrupt) Page Diagram for connecting push plates and or card readers for Night mode. Page Electric Locks Fail Safe Page Electric Locks Fail Secure Page Troubleshooting Page -7 ENTRANCES INC - -

3 Electrical Information WARNING Disconnect all power to the junction box prior to making any electrical connections. Wiring must meet all local, state, federal or other governing agency codes. Failure to do so may result in serious personal or fatal injury. Note: Since the Model 7 Slider is predominantly wired at the factory the site installer/electrician has a relatively simple task.. Convenient electric service access holes have been provided in the slide header end caps and jamb tubes. An installer/electrician should route 0 VAC, single phase, AMP (MINIMUM) power to the factory supplied and mounted junction box in the header. Ground Hot Common Factory Wiring. The installer/electrician should connect one power hot lead () to the power cut off switch mounted inside the junction box. Utilizing an appropriate wire nut, the installer/electrician should connect the common lead () to the loose common lead () found inside the junction box. The ground wire should be connected to the ground screw located in the back of the switch junction box. DN 000. Replace the junction box cover. The unit s power should now be activated through the building s electrical circuit breaker box. Proceed with performance set-up procedures outlined in the Microprocessor and Handy Terminal Manual p/n 9000 ENTRANCES INC - -

4 NO. COLOR Motor Connector ( pin) NO. COLOR USE Motor V Phase Power Connector ( pin) USE Not Used VAC Common VAC Hot Not Used Encoder VDC Encoder A Phase Motor U Phase Encoder Ground Encoder B Phase NO. SYMBOLCOLOR 9DCV B H M0 M SQ BA OUT + OUT - CAUTION Violet Fuse Inside Rating: V, A Size:. x 0mm WARNING against fire, replace only For continued protection with a fuse of the same type and rating. No. Sliders Electrical Manual Typical Slider Wiring Wiring diagrams are included in the back of this manual, which reflect the typical primary and secondary circuits installed at the factory. The low voltage ( VDC) Reed switch (panic break away) and Acusensor are easily connected on site using factory installed connector housings. The factory uses Underwriters Laboratories (UL) recognized component wire, terminals and connector housings to manufacture the slider. Contact the Customer Service Department for assistance with special applications. WARNING Microprocessor controller contains HIGH VOLTAGE! Installation should be performed by qualified personnel only. Wiring must meet all local, state, federal or other governing agency codes. Failure to do so may result in serious personal or fatal injury. SERVICE GROUND 0 VAC "COMMON" 0 VAC "HOT" MINIMUM AMPERE SERVICE PER OPERATOR OPERATOR SWITCH BOX MOTOR 0097 Telescopic Operator 98 7 Slider Operator MTR. HARNESS & PLUG HANDING HARNESS PT. NO RIGHT HAND UNITS ONLY YELLOW GRAY VIOLET M0 M USED FOR SEQUENTIAL OPERATION USED FOR ELECTRIC LOCK USED FOR ELECTRIC LOCK Second pulley for Telescopic units only. + VDC Microprocessor Controller PT. NO ON OFF NIGHT ONE WAY HOLD OPEN TWO WAY FULL OPEN UCED OPEN BACK SIDE OF SWITCH SHOWN. PLUG FOR HANDY TERMINAL New Switch U and later models. PN 98-0 Handy Terminal Connector ( pin) OFF ON DOOR OPERATION ONLY NIGHT ONE WAY ROCKER SWITCH EXTENSION HARNESS PT. 98 SW. EXT. HARNESS PT. NO. -90 MAGNETIC POWER DOWN SWITCH PT. NO. 9 Yel INTERIOR ACUSENSOR PT. NO. 890 ACUSENSOR EXTENSION HARNESS PT. NO. -97 PT. NO. 98 PLUG WITH JUMPER MUST BE IN PLACE PN 0 ACUSENSOR HARNESS HOLDING BEAM CONNECTOR. USE ONLY WITH HOLDING BEAMS! SW. EXT. HARNESS PT. NO. -90 MAGNETIC POWER DOWN SWITCH PT. NO. 9 Yel ACUSENSOR EXTENSION HARNESS PT. NO. -97 EXTERIOR ACUSENSOR PT. NO. 890 ACUSENSOR HARNESS PT. NO. 98 AUTO HOLD OPEN FULL OPEN UCED OPEN Old Switch U and earlier models. DN 000 BACK SIDE OF SWITCH SHOWN. General Wiring Diagram ENTRANCES INC - -

5 Microprocessor Controller Slider Schematic Wiring Diagram - U0 and Higher Microprocessor Internal Amp Relay Nabco "U" Series Microprocessor PN 980 (9DCV) Violet (out+) (out-) (SQ) (B) () () (7) (BA) (M0) (M) (H) Panic Breakout Switch (normally closed contacts) Exterior Sensor N.O. contacts Interior Sensor N.O. contacts Holding Beams N.O. contacts Sequential Wall Switch Rocker Switch Bank ON/OFF Rocker Switch uced Opening Logic Circuit Logic Circuit Panic Breakout / Stop Circuit Panic Breakout Switch (normally closed contacts) Panic Breakout Switch (normally closed contacts) (Common) no Activation 0 Activation no Activation 0 Activation no Activation 0 Activation Auxiliary Output (this switch acts like a door sequencer) + VDC 0 VDC if Panic Circuit Closed and Rocker Switch Turned "ON" VDC if Panic Circuit Open or Rocker Switch Turned "OFF" All voltages shown measured with respect to (Common) DN000 By alternately switching the two MO & M (orange wires) on the microprocessor harness to (common) the various door modes such as HOLD OPEN mode, EXIT mode, NIGHT mode etc. are achieved. (Off = not switched to commonon = switched to common) (BA) wire must remain tied to (Common) for door to function. Refer to Page 9 for more information ENTRANCES INC - -

6 Microprocessor Controller The Microprocessor controller has been designed to control the numerous operating characteristics of the slide door system including speed, recycling and door opening width. It will need to be programmed after the installation is complete. (See the Microprocessor Manual p/n 9000 for more details). CAUTION: Read and understand the Microprocessor Manual p/n 9000 before attempting to power-up the door. Failure to do so may result in damage to the door and/or injury to the installer and will nullify all warranties. Rocker Switch Connector Microprocessor Main Harness Diagram M MO MO Grey Breakaway Connectors Holding Beam Connector Interior Accusensor Connector Rocker Switch Extension Harness PN 98 Purple M CN CN Exterior Accusensor Connector NOTE: In some cases the interior and exterior Accusensors are reversed Handy Terminal Connector Rocker Switches (Old) U and earlier models. ON DOOR OPERATION ONLY OFF NIGHT ONE WAY HOLD OP EN AUTO FULL RE DUCE D OPEN Backside of both switches shown. Rocker Switches (New) ON U and later models. PN 98-0 OFF TWO WAY NIGHT ONE WAY HOLD OPEN FULL OPEN UCED OPE N CN 0 VAC M.C. Ground CN Main Breaker Switch in Header Motor Plug DN 000 ENTRANCES INC - -

7 Sliders Electrical Manual Dual Operator Wiring Diagram Breakout Switch A side door Breakout Switch Harness Extension //00 DUAL OPERATOR WIRING DIAGRAM O N O FF NI G HT ROCKER SWITCHES P/N: 98-0 LABEL A TWO WA Y (M0) (M) O NE W AY HO LD O PEN ACUSENSOR (INTERIOR SIDE) FULL OPEN UCED O PEN () (9DCV) (7) () (B) (H) (M0) (M) () (BA) (OUT-) Violet(OUT+) (SQ) GYRO TECH LABEL B C PO W ER SO URCE ( P) HANDY TERM I NAL ( P) NO CO. LO R USE SENSO R ( P) EM PTY W HI TE VAC CO M M O N NO. SYM BO CO L LO USE R [ SLI DER/ SW I NG ER] VAC HO T 9DCV BRO W N VDC + EM PTY 7 VDC -, CO M M O N APPRO ACH O PERATO R ( P) B W HI TE THRESHO LD SENSI NG FUSE I NSI DE NO CO. LO R USE / PRESENCE SENSO R RATI NG : V, A H G REEN UCED O PENI NG M O TO R V PHASE SI ZE:. x 0m m / SAFETY M AT O RANG ENCO DER VDC W ARNI NG 0 RANG DE SW BRO W N ENCO DER A PHASE M O RANG E M O DE SW For cont inued prot ect ion M O TO R U PHASE O RANG E APPRO ACH( THRO UG H) against f ir e, r eplace only ENCO DER G ND wit h s am e t y pe and r at ing SQ YELLO W SEQ UENTI AL YELLO W ENCO DER B PHASE of f us e. 0 BA BREAK O UT O UT + VI O LET O UTPUT + CAUTI O N O UT - G RAY O UTPUT -. Please adjust t his oper at or as per inst r uct ion m anual.. Tur n t he power of f, bef or e opening t he box.. Don't open t his box except f or replacing f use. O t her wise, t he war r ant y wil be t er m inat ed.. Repair of t his unit except by Nabco Ent r ances, I nc. m ay cause sof t war e and har dwar e m alf unct ion. A NOT USED LABEL A HARNESS FOR SLIDER SIMULTANEOUS PAIR P/N: 90 (9DCV) (7) () (B) (H) (M0) (M) () (BA) (OUT-) Violet(OUT+) (SQ) GYRO TECH () D PO W ER SO URCE ( P) HANDY TERM I NAL ( P) NO CO. LO R USE SENSO R ( P) EM PTY W HI TE VAC CO M M O N NO. SYM BO CO L LO USE R [ SLI DER/ SW I NG ER] VAC HO T 9DCV BRO W N VDC + EM PTY 7 VDC -, CO M M O N APPRO ACH O PERATO R ( P) B W HI TE THRESHO LD SENSI NG FUSE I NSI DE NO CO. LO R USE / PRESENCE SENSO R RATI NG : V, A H G REEN UCED O PENI NG M O TO R V PHASE / SAFETY M AT SI ZE:. x 0m m O RANG ENCO DER VDC W ARNI NG 0 RANG DE SW BRO W N ENCO DER A PHASE M O RANG E M O DE SW For cont inued prot ect ion M O TO R U PHASE O RANG E APPRO ACH( THRO UG H) against f ir e, r eplace only ENCO DER G ND wit h s am e t y pe and r at ing SQ YELLO W SEQ UENTI AL YELLO W ENCO DER B PHASE of f us e. 0 BA BREAK O UT O UT + VI O LET O UTPUT + CAUTI O N O UT - G RAY O UTPUT -. Please adjust t his oper at or as per inst r uct ion m anual.. Tur n t he power of f, bef or e opening t he box.. Don't open t his box except f or replacing f use. O t her wis e, t he war r ant y wil be t er m inat ed.. Repair of t his unit except by Nabco Ent r ances, I nc. m ay cause sof t war e and har dwar e m alf unct ion. B LABEL B NOT USED Breakout Switch B side door (M0) (M) Plug Rocker Switch #98-0 into MC Harness #890 at C Receptacle of #90 harness. Plug both Breakout Switches #9 into MC Harness #890 at D Receptacle of Harness #90. DN007 ACUSENSOR (EXTERIOR SIDE) MICROPROCESSOR CONTROLLER (MC) (with special harness) P/N: 890 If this is not followed, Breakout will not function properly. ACUSENSOR (INTERIOR SIDE) ACUSENSOR (EXTERIOR SIDE) MICROPROCESSOR CONTROLLER (MC) (with special harness) P/N: 890 If this is not followed, Breakout will not function and the Breakout Switches #98 may weld shut and need to be replaced. A door stop is needed at the center of the header to stop the doors independently. JUMPER PLUG FOR SIMULTANEOUS PAIR P/N: 98 ENTRANCES INC

8 ACUSENSOR/ACUMOTION Sliders Electrical Manual The header is wired from the factory so that the activation circuitry on the exterior sensor is turned off in One Way Traffic Mode (the safety circuitry remains active and can not be turned off). The exterior sensor is located on the side of the header in the direction of panic or panel breakout. This can easily be reversed in the field by swapping the connectors where each sensor plugs into the main harness. Acusensor PN 890 Acusensor Harness (#98) Acusensor Extension Harness (#97-0 8" Long) (#97-0 " Long) or Exterior Sensor Interior Sensor Main Harness Acumotion 0 Acusensor Harness (#98) DN 000 Acusensor Extension Harness (#97-0 8" Long) (#97-0 " Long) or Main Harness Exterior Sensor Interior Sensor ENTRANCES INC

9 How Door Function Modes are Achieved via the Rocker Switches OFF OFF Auto Mode. Both sensor signals are available Electric Lock is always unlocked. Sliders Electrical Manual By alternately switching the two MO & M (orange wires) on the microprocessor harness to (common) the various door modes such as HOLD OPEN mode, EXIT mode, NIGHT mode etc. are achieved. Refer to the tables below. (Off = not switched to common MO M Results On = switched to common) OFF ON Night Mode. None of the sensor signals will be accepted. Sensors will provide threshold safety and electric lock is always locked. Activation must occur by means of an exterior activation device such as a card reader or key switch. ON ON Hold Open Mode. The door keeps the full open point, not affected by sensors. Electric Lock is always unlocked. ON OFF One Way Traffic. The interior sensor activates the door; the exterior sensor provides threshold safety. Electric Lock is locked until an interior activation is received The table at right summarizes the functions as outlined above: MODE SWITCH TABLE MO M Mode OFF OFF Automatic Mode OFF ON Night Mode ON ON Hold Open Mode ON OFF One Way Mode ENTRANCES INC

10 Holding Beams (Activation Hold Open) The Holding Beam is a factory-installed unit consisting of an emitter, detector and control box. They are flush mounted in door frames and/or jamb tubes, facing each other along the threshold. A pulsed, infrared light beam is continuously transmitted across the door opening. Interruption of the beam will switch the holding beam input wire to (Common). This will cause the system to re-activate and hold open until the interruption is cleared. Optex OA-0C Beams on a GT-7 Wiring Diagram for Holding Beams (U0 and Higher) Connect Each Terminal the Same Term # & Color Plastic Conductor Braided Shield RCVR EMTR Jacket color EMTR RCVR Terminal # Terminal # Panic Breakout Switch or Plug with Jumper connects here. Interior Motion Sensor Panic Breakout Switch or Plug with Jumper connects here. Not used Panic Breakout Switch or Plug with Jumper connects here. Exterior Motion Sensor Terminal # Optex OS-0C Controller Optex Controller and One RCVR & One TRANS PT. NO Terminal # DN 000 PN -088 ENTRANCES INC - 0

11 Holding Beam (Breakout Power Interrupt) Sliders Electrical Manual The Holding Beam is a factory-installed unit consisting of an emitter, detector and control box. They are flush mounted in door frames and/or jamb tubes, facing each other. A pulsed, infrared light beam is continuously transmitted across the door opening. Interruption of the beam by breaking out a door panel will interrupt the blue wire power down loop. This will cause the system to stop operating until the door panel is repositioned and latched. Optex OA-0C Beams on a GT-7 Wiring Diagram for Breakout Beams (U0 and Higher) Connect Each Terminal the Same Term # & Color Plastic Conductor Braided Shield RCVR EMTR Jacket color Terminal # Terminal # Interior Motion Sensor Panic Breakout Switch or Plug with Jumper connects here. Holding Beams Panic Breakout Switch or Plug with Jumper connects here. Exterior Motion Sensor Terminal # Optex OS-0C Controller Optex Controller and One RCVR & One TRANS PT. NO Terminal # Jumper DN 000 PN -087 Hold Beam Pigtail PT. NO. 087 ENTRANCES INC -

12 Diagram for connecting push plates and or card readers for Night mode. Attach the normally open contacts across the red and black wire on either the rocker or key switches. NEW ROCKER SWITCH U and later models. PN 98-0 ON OFF TWO WAY NIGHT ONE WAY HOLD OPEN FULL OPEN UCED OPEN Push buttom switch during night mode. OLD ROCKER SWITCH U and earlier models. Push buttom switch during night mode. Backside of switch. Push buttom switch during night mode. AUTO H.O. EX IT NIGHT (#) (#) (#) Closing contacts with door in NIGHT mode opens door. RE DUCE D FULL STOP ON Breakaway Connectors (#8) (#) (#) KEY SWITCH PN 980 DO O R O PERATIO N O NLY O FF NIGHT ONE WAY HOLD OPEN AUTO FULL UCED OPEN Backside of switch. Rocker Switch Connector M MO 7 Microprocessor Wire Diagram Activation with Night mode. Connect card reader and wall plate normally open dry contacts as shown. Access in the header. DN 0007 ENTRANCES INC -

13 Electric Locks Fail Safe RELAY(DCV) 90 Wire Nut 0 No. MICROPROCESSOR CONTROLLER GYRO TECH MOV 07 9DCV () HANDY TERMINAL (P) POWER SOURCE (P) SENSOR (P) USE [SLIDER/SWINGER] USE EMPTY VAC COMMON COLOR NO. OUT+ (VIOLET) COLOR SYMBOL 9DCV NO. 7 VAC HOT EMPTY B H FUSE INSIDE RATING:V,A SIZE:. x 0mm OPERATOR (P) USE WARNING OUT- (GRAY) YELLOW VIOLET GRAY M0 M SQ BA OUT + OUT For continued protection against fire, replace only with same type and rating of fuse. MOTOR V PHASE ENCODER VDC ENCODER A PHASE MOTOR U PHASE ENCODER GND ENCODER B PHASE COLOR YELLOW NO C A U T I O N VIOLET 09 7 () GYRO TECH ELECTRIC LOCK / STRIKE E N T R A N C E S LANSON INDUSTRIES INC..Please adjust this operator as per instruction manual..turn the power off, before opening the box..don't open this box except for replacing fuse. Otherwise, the warranty will be terminated..repair of this unit except by Lanson Industries, Inc. may cause software and hardware malfunction. Fail Safe Type (GRN) (BLK/WHT) (OR) TRANSFORMER ACV (YEL) (BLK/WHT) (OR) ACV RECTIFIER KIT PN 07-0 NOTE: LOCK WORKS ONLY IN NIGHT & EXIT MODES ON ACTIVATE SIGNAL LOCKED LOCKED UNLOCKED (ON) OUTPUT SIGNAL CLOSED OPEN >>> CLOSE CLOSED Handy Terminal : Aux. Output [0], time delay [0]~[] Mode Input : One Way Traffic Mode or Night Mode DOOR time delay(0.~sec) time delay(0.~sec) DN 0008 ENTRANCES INC -

14 Electric Locks Fail Secure RELAY(DCV) 90 Wire Nut 0 No. MICROPROCESSOR CONTROLLER G Y R O T E C H DN DCV () HANDY TERMINAL (P) POWER SOURCE (P) SENSOR (P) USE [SLIDER/SWINGER] USE EMPTY VAC COMMON COLOR NO. COLOR SYMBOL 9DCV NO. 7 VAC HOT EMPTY OUT+ (VIOLET) B H FUSE INSIDE RATING:V,A SIZE:. x 0mm OPERATOR (P) USE MOV VIOLET 09 YELLOW VIOLET GRAY M0 M WARNING SQ BA OUT + OUT For continued protection against fire, replace only with same type and rating of fuse. MOTOR V PHASE ENCODER VDC ENCODER A PHASE MOTOR U PHASE ENCODER GND ENCODER B PHASE COLOR YELLOW NO. OUT- (GRAY) C A U T I O N 7 () (GRN) GYRO TECH E N T R A N C E S LANSON INDUSTRIES INC..Please adjust this operator as per instruction manual..turn the power off, before opening the box..don't open this box except for replacing fuse. Otherwise, the warranty will be terminated..repair of this unit except by Lanson Industries, Inc. may cause software and hardware malfunction. Fail Secure Type (BLK/ WHT) (BLK/ WHT) (YEL) (OR) TRANSFORMER ACV ELECTRIC LOCK / STRIKE Wire Nut 0 (OR) ACV RECTIFIER KIT PN 07-0 NOTE: LOCK WORKS ONLY IN NIGHT & EXIT MODES ON ACTIVATE SIGNAL LOCKED LOCKED UNLOCKED (ON) OUTPUT SIGNAL CLOSED OPEN >>> CLOSE CLOSED DOOR Handy Terminal : Aux. Output [0], time delay [0]~[] Mode Input : One Way Traffic Mode or Night Mode time delay(0.~sec) time delay(0.~sec) ENTRANCES INC -

15 Trouble Shooting LABEL: DOOR POSTION TEST HARNESS FOR GT 00/00/00/70 MAGNUM CONTROL LABEL: TEST HARNESS FOR GT 00 LABEL: MICROPROCESSOR SWITCH JUMPER PLUG LABEL: PANIC SWITCH BYPASS PLUG LABEL: MICROPROCESSOR JUMPER PLUG Instruction Set for Distributor Test Harness Kit Microprocessor Jumper Plug Panic Switch Bypass Plug Microprocessor Switch Jumper Plug Microprocessor Test Plug 07 Test Harness for GT 00/00/00 Analog Control 08 Test Harness for GT 00 0 Door Position Harness for Magnum Control ITEM QTY PART NO. DESCRIPTION DN0070 LABEL: TEST HARNESS FOR GT 00/00/00 ANALOG CONTROL ENTRANCES INC. S8 W877 Gemini Drive P.O. Bo x 90 Muskeg o, W I 0 Ph one : F ax : Technical Assistance: Instruction Set for Distributor Test Harness Kit Test Kit Manual Part # -00 May 00 DATE: --0 SCALE: None DRAWN BY: MB APP. BY: Jc TOLERANCES (UNLESS NOTED) FRACTIONAL ± X ±.00 XX ±.0 XXX ±.00 ANGLE ± SHEET #: OF ERN 89 REVISIONS DATE --0 LABEL: MICROPROCESSOR TEST PLUG 8 PART NAME: Distributor Test Harness Kit MATERIAL: SPECIFICATIONS: B Drawing No. Part No. 0 ENTRANCES INC -

16 Troubleshooting. Acusensor does not seem to reach out far enough a) Move the area lever on the side of the Acusensor to a higher number. b) Increase the opening speed on the door with the Handy Terminal. c) If desired, replace Acusensor with Acumotion for greater detection range.. Acusensor is not seeing people accessing the door from the side. a) Turn on more of the area switches on the front of the Acusensor. b) Door is set to One Way Traffic mode and sensor is switched out. Set door to Auto mode.. When the doors are panicked open, the system does not shut down. a) Check the wiring of the power down switch in the fixed panel or bottom of header. (Full Open Units.) (BA) circuit must go open for system to shut down. b) Check the wiring of the breakout beam circuit. (Surface Applied Units.) (BA) circuit must go open for system to shut down.. Doors do not move when power is applied or Handy Terminal connected. a) Confirm the swing panel is closed completely. b) Confirm (BA) circuit is not open. Zero VDC between and on microprocessor harness for correct operation. If VDC circuit is open. b) Check the power down magnet in the top rail of the swing panel is installed and aligned with the magnetic power down switch in the bottom of the header. c) Confirm rocker is switch is set to ON not OFF.. The cover on the Acusensor will not snap on. a) Install thin washers to space the Acusensor off from the header and provide clearance for the cover.. Doors move very slowly when the Handy Terminal is connected. (Only happens after Stroke Cycle initiated.) a) This is normal. It is learning the door stroke. b) After learning the stroke, the Handy Terminal will prompt you with options 7. The doors do not open completely. a) Look for obstructions in the track as well as inside the header. Check to make sure that the belt clips are not hitting something. b) On Full Open units be sure that the interlock clips are adjusted properly. c) Check for any racking in the door. b) Check that the mode switch on the panel is not in uced Opening mode. c) Use the Handy Terminal and reinitialize the system. 8. I want to eliminate all outside switches and sensors and test the system with the Handy Terminal. a) Disconnect the -pin connector from inside the microprocessor and install the special connector jumper tool p/n 9 into its place. b) The system will consist of only the motor, operator and control box (Microprocessor). The Handy Terminal will be the only means of operating the door. ENTRANCES INC -

17 Troubleshooting 9. I want to reset the system back to the factory settings. a) Plug in Hand Terminal and wait for the door to close. b) At Swing/Slide/Stroke? enter YES. c) At Swing Door Y or N? enter YES (even though you have a slide door). d) Door will try to initialize as a swing door and reset the settings. e) At Swing/Slide/Stroke? enter YES. f) At Swing Door Y or N? enter NO. g) The system will now initialize as a slide door to the factory settings. h) You must set the door stroke from the Handy Terminal from the prompts at this point. 0. Door does not run unless holding beam is interrupted. a) The holding beam connector (it has a red and white wire in it) in the main harness may be inadvertently plugged into one of the Power Down (blue wires) plugs. Any vacant Power Down plugs should have a blue jumper installed. For technical assistance call: 8--8 or engineering at: ENTRANCES INC - 7

Setup and Programming Manual

Setup and Programming Manual Microprocessor and Handy Terminal Setup and Programming Manual Versions U04 to U19 for Sliding Door Systems P/N 159000 Rev 7-2-07 The manufacturer, NABCO Entrances, Inc. suggests that this manual be given

More information

Model GT 1175 Electrical Installation Manual **with U30 Microprocessor Controller** (with Revision D Software)

Model GT 1175 Electrical Installation Manual **with U30 Microprocessor Controller** (with Revision D Software) A M P MADE IN JAPAN GYRO TEC 0V MOTOR P POWER B ERROR GYRO TEC To protect against risk of fire or electric shock,use only the certified power supply. Adjustments to the door can only be made with the andy

More information

Turn OFF all power to the Automatic Door if a Safety System is not working.

Turn OFF all power to the Automatic Door if a Safety System is not working. This document is meant to serve as a Quick Set-Up Guide only. Installation manuals referenced below should be downloaded from the NABCO Website and reviewed for complete installation instructions. GT U-0

More information

Swing Door Operator Wiring and Adjustment Manual ** with Magnum 4A Control*

Swing Door Operator Wiring and Adjustment Manual ** with Magnum 4A Control* S82 W18717 Gemini Drive Muskego, Wisconsin 53150 Phone: (877) 622-2694 ax: (888) 679-3319 www.nabcoentrances.com Technical Support: (866) 622-8325 Swing Door Operator Wiring and Adjustment Manual ** with

More information

GT 710. Surface-Mounted, Low Energy, ADA*, Fire-Rated Swing Door Operator PRODUCT FEATURES

GT 710. Surface-Mounted, Low Energy, ADA*, Fire-Rated Swing Door Operator PRODUCT FEATURES GT 710 Surface-Mounted, Low Energy, ADA*, Fire-Rated Swing Door Operator The GT 710 operates in both automatic and manual modes. It features a 2-60 second hold-open range and a push-n-go feature. The GT

More information

USERS GUIDE LO-21U LOCKOUT RELAY

USERS GUIDE LO-21U LOCKOUT RELAY USERS GUIDE LO-21U LOCKOUT RELAY PRODUCT DESCRIPTION The LO-21U (PN: 10LO21U) is a micro-processed lock out module designed to operate on swing door applications with BEA s Bodyguard or DK-12 overhead

More information

POWERLINE 2000 Energy Management System TM

POWERLINE 2000 Energy Management System TM Display Panel TM The PowerLine 00 EMS is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed in the standard main distribution

More information

Section E Fixed Sidelight All Glass. Header Showing U04 to U19 Drive Train Door Panels DS150 and U30 Drive Train...

Section E Fixed Sidelight All Glass. Header Showing U04 to U19 Drive Train Door Panels DS150 and U30 Drive Train... Section E1 1 Fixed Sidelight All Glass Header Showing U0 to U19 Drive Train................................................... 3- Door Panels........................................................................

More information

Automatic Sliding Door Retrofit Drive Assembly. Installation Manual DoorControlsUSA.com

Automatic Sliding Door Retrofit Drive Assembly. Installation Manual DoorControlsUSA.com Automatic Sliding Door Retrofit Drive Assembly Installation Manual 800-437-3667 DoorControlsUSA.com TABLE OF CONTENTS pg. 1. COMPONENTS 2 2. HEADER PREPARATION 2 3. DOOR PREPARATION 2 4. MOTOR AND CONTROLLER

More information

Senior Swing Control Box. Table of Contents

Senior Swing Control Box. Table of Contents *740100* 740100 2800 Overhead Consealed Series 9500 Surface Applied Series Senior Swing Control Box Installation Instructions important These instructions are presented in step-by-step sequence. It is

More information

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI II 1400-6 ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI ACSI 1426-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1092, REV. C INSTALLATION For C-UL Listed applications,

More information

Gyro Tech Swing Door Conversion Unit (C.U.) Hardware Installation and Service Manual

Gyro Tech Swing Door Conversion Unit (C.U.) Hardware Installation and Service Manual S82 W18717 Gemini Drive PO Box 906 Muskego, WI 53150 Phone: (877) 622-2694 Fax: (888) 679-3319 www.nabcoentrances.com Gyro Tech Swing Door Conversion Unit (C.U.) Hardware Installation and Service Manual

More information

2904 Power Supply Installation Instructions I-EA00041

2904 Power Supply Installation Instructions I-EA00041 FEATURES Controls an opening with electrified locking device and automatic door operator Separate inputs for activation switch on entry and exit sides of opening Separate 24 VDC outputs for fail safe and

More information

6100 Series Swing Door Operator Installation Instructions

6100 Series Swing Door Operator Installation Instructions 6100 Series Swing Door Operator Installation Instructions The manufacturer s specifications for this product require the installation to be approved by an AAADM certified inspector. -USA 4324 Phil Hargett

More information

INSTRUCTION MANUAL H WELDER INTERLOCK

INSTRUCTION MANUAL H WELDER INTERLOCK INSTRUCTION MANUAL 700200H WELDER INTERLOCK MICROPROCESSOR BASED Welder Interlock Control Wiring Diagram 420721 NEMA 1 Cabinet ENTRON Controls, LLC. 1402 S. Batesville Road Greer, South Carolina 29650

More information

What s on your truck? MOTIONACCESS, LLC. Installation & Operation Manual

What s on your truck? MOTIONACCESS, LLC. Installation & Operation Manual What s on your truck? Installation & Operation Manual Terminal Block Keypad Controller Cover & Label "Quick Harness" Sensors / Switches Connections A Digital Comm. B common C Thres. Sensor D common E Breakaway

More information

LCN AUTOMATIC OPERATORS

LCN AUTOMATIC OPERATORS LCN AUTOMATIC OPERATORS SENIOR 9530 SENIOR 9540 SENIOR 9550 SENIOR 9560 8310 ACCESSORIES LCN ELECTROMECHANICAL POWERED SYSTEMS ELECTROMECHANICAL AUTOMATIC OPERATORS LCN s electromechanical products are

More information

Power Supplies DORMA PS

Power Supplies DORMA PS Power Supplies DORMA PS DORMA PS Power Supplies Main System On/Off or Fire Panel Relay - The power supply output voltage can be controlled by the main system on/off control relay which accepts a closed

More information

30A SMART ENERGY MANAGEMENT SYSTEM TM

30A SMART ENERGY MANAGEMENT SYSTEM TM 30 Amp EMS Display Panel P/N 00-00903-030 (Black) 30 Amp EMS Distribution Panel P/N 00-0091-000 CAUTION The 30A SMART EMS is a centralized power switching, fusing, and distribution center. Power from the

More information

Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin

Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin NABCO ENTRANCES TECHNICAL BULLETIN S82 W18717 Gemini Drive Muskego,

More information

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-10 ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS Features: Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit Protection Standby Battery

More information

Package Unit Modulating Economizer Installation Instructions

Package Unit Modulating Economizer Installation Instructions Package Unit Modulating Economizer Installation Instructions Downflow Unit Warning: Recognize this symbol as an indication of Important Safety Information! Read all instructions prior to installation.

More information

Series 2003T. Belt Drive Telescoping Slide Door INSTALLATION INSTRUCTIONS. To be used with H210 C2150 Ver.10 Control Setup Instructions

Series 2003T. Belt Drive Telescoping Slide Door INSTALLATION INSTRUCTIONS. To be used with H210 C2150 Ver.10 Control Setup Instructions Series 2003T Belt Drive Telescoping Slide Door INSTALLATION INSTRUCTIONS To be used with H210 C2150 Ver.10 Control Setup Instructions DIRECTION OF DOOR OPENING G230T, JUNE 2009 A U T O M A T I C S G230T.1

More information

Gate & Door Controller with LCD and Intelligent Technology

Gate & Door Controller with LCD and Intelligent Technology 2nd Edition Gate & Door Controller with LCD and Intelligent Technology 24Sv1 and 12Sv1 Motor Controllers Setup and Technical information for single motor controller for gates & doors Includes latest Intelligent

More information

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit R Vehicle Security INSTALLATION MANUAL Model: PLUS-4700 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference;

More information

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY 00 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) Track Assembly (0-) / Replacement

More information

50 AMP Smart Energy Management System Model 800 SERVICE MANUAL 50 AMP SMART EMS. 50 Amp EMS Display Panel P/N A I N A I N

50 AMP Smart Energy Management System Model 800 SERVICE MANUAL 50 AMP SMART EMS. 50 Amp EMS Display Panel P/N A I N A I N R SERVICE MANUAL 50 AMP SMART EMS 50 Amp EMS Display Panel P/N 00-00684-000 LINE 1 LINE 2 6 5 4 3 2 1 6 5 4 3 2 1 M M 1 2 3 4 5 6 A I N A I N INVERTER LOADS SUBPANEL DANGER: HAZARD OF ELECTRICAL SHOCK

More information

3 Phase Smart Controller

3 Phase Smart Controller 3 Phase Smart Controller Installation and Owner s Manual STP-SCIII 208-230 VAC, 60Hz, 120 Volt Coil Franklin Fueling 3760 Marsh Rd. Madison WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 47681 Vari-Green Motor and Controls Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

Rolling Door Operator User s Manual

Rolling Door Operator User s Manual Rolling Door Operator User s Manual MODEL: RSI-500KG Rolling Steel Ind. Brooklyn NY Tel. 718 272-4444 OUTLINE 1. Important safety information 1 2. Main technical parameters 1 3. Introduction 1 4. Installation

More information

Electrohydraulic Powered Systems

Electrohydraulic Powered Systems Electrohydraulic Powered Systems ELECTRIC AUTO EQUALIZERS These Auto Equalizer products are an addition to the original pneumatic drive system. People moving through a door can use it as a normal rack

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

KEANE MONROE a member of the record group

KEANE MONROE a member of the record group SERIES 3000 / 3100 MICROPROCESSOR CONTROL REGULAR ARM SLIDE ARM / SLIDE ARM W/PANIC BREAKAWAY SERIES 3000 / 3100 Page 1. INDEX and OPERATOR HANDING The KM Series 3000/3100 operators have been carefully

More information

Electro-Mechanical Swing Operator. Table of Contents

Electro-Mechanical Swing Operator. Table of Contents *640072* 640072 Electro-Mechanical Swing Operator Models 8230 & 8240 Installation Instructions Table of Contents General...1 Replacement Parts & System Components...1 1 Pre-Installation Site & Product

More information

HYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator

HYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator HYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator Manufactured by NICE SpA INSTALLATION MANUAL 08/10 CONTENTS IMPORTANT SAFETY INSTRUCTIONS... 3 Applications...... 4 Pre-Installation Checklist... 5

More information

Installation and Maintenance Manual

Installation and Maintenance Manual Installation and Maintenance Manual Swing Gate Operator Model HL410-21 & HL410L-21 2 Contents Contents Parts & Components 3 Specifications & Capacities 4 Safety Information 6 Installer 6 End User 7 General

More information

INSTALLATION MANUAL. Remote Mobile Security System. Model: PL30

INSTALLATION MANUAL. Remote Mobile Security System. Model: PL30 Remote Mobile Security System INSTALLATION MANUAL Model: PL30 Copyright 1998 Magnadyne Corporation For Technical Assistance (800) 638-3600 For Fax on Demand Technical Assistance (800) 994-9977 (Must be

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Series 2001 Belt Drive Slide Door & RapidSlide INSTALLATION INSTRUCTIONS To be used with H202 C2150 Ver.2 Control Setup Instructions G2001, FEB 2004 CONTENTS 1. Instructions to installer... G2001.1 2.

More information

SKC400U SLIDING GATE OPENER OWNER S MANUAL

SKC400U SLIDING GATE OPENER OWNER S MANUAL SKC400U SLIDING GATE OPENER OWNER S MANUAL IMPORTANT SAFTEY INFORMATION Installing the SKC400U Gate Opener requires wiring of standard 110V electrical lines. This should only be performed by a trained

More information

Technical Installation and Service Manual

Technical Installation and Service Manual 1. 2. 7 3. 4. Technical Installation And Service Manual RS-500 Door with Brother Operator RollSeal 1733 County Road 68 Bremen, Alabama 35033 256-287-7000 Part No 4801-5159 Rev 11-2015 Technical Installation

More information

Installation Instructions & Users Manual

Installation Instructions & Users Manual Installation Instructions & Users Manual UTILITY/ BUILDING INPUT 120 VAC ( OPTION) 15-20A N L CONTROL BOARD G SECURITY LIGHTING POWER SUPPLY (OPTION) CHARGER- POWER SUPPLY ASSBY XFMR (OPTION) CBM MODEL

More information

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4) Parts Manual Transfer Switch 50/225/260 Amps OTPCB (Spec A) English Original Instructions -203 962 0228 (Issue ) This catalog covers models produced under the Cummins /Onan and Cummins Power Generation

More information

YG101 SWING GATE OPENER OWNER S MANUAL

YG101 SWING GATE OPENER OWNER S MANUAL YG101 SWING GATE OPENER OWNER S MANUAL IMPORTANT SAFTEY INFORMATION Installing the YG101 Gate Opener requires wiring of standard 110V electrical lines. This should only be performed by a trained technician.

More information

INSTRUCTIONS FOR REMOVAL OF GROUND FAULT PROTECTION DEVICE FROM HOBART GENERATOR SETS SPECIFICATION NUMBERS

INSTRUCTIONS FOR REMOVAL OF GROUND FAULT PROTECTION DEVICE FROM HOBART GENERATOR SETS SPECIFICATION NUMBERS 081385 INSTRUCTIONS FOR REMOVAL OF GROUND FAULT PROTECTION DEVICE FROM HOBART GENERATOR SETS SPECIFICATION NUMBERS 6184-2 HOBART BROTHERS COMPANY Power Systems Division Troy, Ohio 45373 INSTRUCTIONS FOR

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 47681 Vari-Green Motor and Controls Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 473681 Vari-Green Motor and Controls Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble,

More information

Technical Installation and Service Manual RollSeal 1733 County Road 68 Bremen, Alabama 35033

Technical Installation and Service Manual RollSeal 1733 County Road 68 Bremen, Alabama 35033 Technical Installation and Service Manual RollSeal 1733 County Road 68 Bremen, Alabama 35033 4801-5159 rev. 05/14 Technical Installation and Service Manual Page 1 of 26 1. Ratings and Specifications Motor

More information

INSTRUCTIONS FOR REMOVAL OF GROUND FAULT PROTECTION DEVICE FROM HOBART GENERATOR SETS SPECIFICATION NUMBER

INSTRUCTIONS FOR REMOVAL OF GROUND FAULT PROTECTION DEVICE FROM HOBART GENERATOR SETS SPECIFICATION NUMBER TO-161 073085 INSTRUCTIONS FOR REMOVAL OF GROUND FAULT PROTECTION DEVICE FROM HOBART GENERATOR SETS SPECIFICATION NUMBER 6184-3..-.-.._. HOBART BROTHERS COMPANY Power Systems Division Troy, Ohio 45373

More information

AS-4000 OPERATING INSTRUCTIONS (PS-5000)

AS-4000 OPERATING INSTRUCTIONS (PS-5000) AS-4000 OPERATING INSTRUCTIONS (PS-5000) BASIC OPERATIONS This unit is a state-of-the-art combination of a vehicle alarm and remote starter system. Start by familiarizing yourself with the alarm functions

More information

SECURITY DOOR CONTROLS

SECURITY DOOR CONTROLS CR4 FOUR STATION CONTROL MODULE The CR4 module operates on 12V or 24V DC and provides control of four (4) stations. Each CR4 station accepts a Dry () trigger input and provides one (1) Fused 2 Amp SPDT

More information

Dor-O-Matic. Series Slide Control. Installation Instructions

Dor-O-Matic. Series Slide Control. Installation Instructions Dor-O-Matic Series 96000 Slide Control Installation Instructions DOR - O MATIC 7350 W. Wilson Ave. Harwood Heights, IL 60706 Toll Free: 1-800-543-4635 In Illinois: 708-867-7400 Sales FAX: 708-867-0291

More information

5600 Series Power Operator Installation and Instruction Manual

5600 Series Power Operator Installation and Instruction Manual 5600 Series Power Operator Installation and Instruction Manual 80-956-000-00 (08-) 5 ASSA ABLOY 6 Item No. Description Motor (5600M) Cover (5600COV) Control Inverter (5600IN) Power Supply VDC (5600PS)

More information

*70954* 240V Senior Swing Control Box Installation Instructions CAUTION WARNINGS. Table of Contents

*70954* 240V Senior Swing Control Box Installation Instructions CAUTION WARNINGS. Table of Contents *70954* 70954 2800 Overhead Concealed eries 9500 urface Applied eries 240V enior wing Control Box Installation Instructions CAUTION These instructions are presented in step-by-step sequence. It is very

More information

GLM SERIES CONTROL Users Manual Rev:

GLM SERIES CONTROL Users Manual Rev: GLM SERIES CONTROL Users Manual Rev: 808062 Connecting Power Page 2 Motor Terminal Wiring Diagrams Page 3 Getting Started / Setup Page 4 1. Obstruction Detection Devices Page 4 2. Checking Power and Direction

More information

Instructions for 2-row monitoring only

Instructions for 2-row monitoring only Installation Instructions for CaseIH cotton picker models: Instructions for 2-row monitoring only CAUTION: Ensure the model numbers shown above correspond to the machine model. If you receive the incorrect

More information

DKC400Y AC Sliding Gate Installation Manual. Sliding Gate Opener. Model: DKC400Y. Installation Manual WARNING

DKC400Y AC Sliding Gate Installation Manual. Sliding Gate Opener. Model: DKC400Y. Installation Manual WARNING Sliding Gate Opener Model: DKC400Y Installation Manual WARNING Read and thoroughly understand all instructions before installing or operating this automatic gate opener. Failure to do so may cause serious

More information

650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present

650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present TOMMY GATE OWNER'S / OPERATOR'S MANUAL 650 Series 650 LB Capacity 650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present Installing the Base Plate 1. Examine the interior and exterior

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 458295 Automatic Fire Damper Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING CAUTION 80-957-00-00 (08-0) Series 570 Door Openings 85 to 0 or to 80 Adjustable Arm and Slide Track Application Maximum Hinge Side Frame Reveal to /8 (mm) Hinge (Pull) Side of Door Installation 5700 LEO

More information

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures. ENGINEERING COMPANY INC. Route 45, Winthrop Road, Chester, Connecticut 0642 Phone: (860) 5269504 Fax: (860) 5264078 Internet: www.whelen.com Sales email: autosale@whelen.com Canadian Sales email: autocan@whelen.com

More information

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4) Parts Manual Transfer Switch 00/00/600 Amps OTPCC (Spec A) English Original Instructions -20 962 0229 (Issue ) This catalog covers models produced under the Cummins /Onan and Cummins Power Generation brand

More information

QUICK INSTALLATION GUIDE

QUICK INSTALLATION GUIDE MANUAL/AUTOMATIC T R A N S M I S S I O N 2 - B U T T O N R E M O T E S T A R T E R W I T H V I R T U A L T A C H S Y S T E M ( A S P R G - 1 0 0 0 C O M P A T I B L E ) QUICK INSTALLATION GUIDE Manual

More information

ModelS. owner S Manual SINGLE SLIDE CLEANROOM DOORS. Manual Single Slide. Power Single Slide

ModelS. owner S Manual SINGLE SLIDE CLEANROOM DOORS. Manual Single Slide. Power Single Slide SINGLE SLIDE CLEANROOM DOORS owner S Manual ModelS 1240 Manual Single Slide 1250 Power Single Slide Do not install, operate or service this product unless you have read and understand the Safety Practices,

More information

50 AMP Smart Energy Management System Model 900 INSTALLATION & SERVICE MANUAL 50 AMP SMART EMS

50 AMP Smart Energy Management System Model 900 INSTALLATION & SERVICE MANUAL 50 AMP SMART EMS R 50 AMP SMART EMS 50 Amp EMS Display Panel P/N 00-00903-050 (Ivory) P/N 00-00903-150 (Black) LINE 1 LINE 2 6 5 4 3 2 1 M M 1 2 3 4 5 6 A A I I N N DANGER: HAZARD OF ELECTRICAL SHOCK OR BURN. TURN OFF

More information

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS PowerMaster TABLE OF CONTENTS MODEL MBG MEDIUM DUTY BARRIER GATE OPERATOR Important Safety Information...... 3 System Designer Safety Instructions.......4 Installer Safety Instructions....... 5 Installation

More information

EMF-2 / EMF-2m Multi-Function Timer

EMF-2 / EMF-2m Multi-Function Timer 0 Timberlea Blvd., Mississauga, LW T Telephone: 0-- Fax: 0-- Toll-Free: --- Web: www.camdencontrols.com EMF- / EMF-m Multi-Function Timer Installation Instructions Ver. A-00 MADE IN ANADA PAGE OF Section

More information

INSTALLATION GUIDE For Surface Mounted Applications (Purchased after 08/01/2018)

INSTALLATION GUIDE For Surface Mounted Applications (Purchased after 08/01/2018) Low Energy Swing Door Automatic Operator INSTALLATION GUIDE For Surface Mounted Applications (Purchased after 08/01/2018) IMPORTANT READ THIS SECTION BEFORE PROCEEDING WITH INSTALLATION Security Door Controls

More information

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B Users Manual Defender 1 8.0KW to 14.0KW Online Lighting Inverter Technical Manual #018-0102-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail:

More information

INSTALLATION GUIDE Table of Contents

INSTALLATION GUIDE Table of Contents CT-3100 Automatic transmission remote engine starter systems. What s included..2 INSTALLATION GUIDE Table of Contents Door lock toggle mode..... 4 Notice...2 Installation points to remember. 2 Features..2

More information

3 in 1 TRAIL CHARGER with LOCKOUT

3 in 1 TRAIL CHARGER with LOCKOUT Owner s Manual P/N: 283821 500 3 in 1 TRAIL CHARGER with LOCKOUT 283821 01 Version 2.04 07/05/2011 Owners Manual Operation Installation Wiring Diagram Troubleshooting Parts Breakdown 1 GENERAL OPERATION

More information

Gen INSTALLATION MANUAL

Gen INSTALLATION MANUAL Gen 2 INSTALLATION MANUAL READ THIS FIRST Installation of this system should be carried out by qualified persons familiar with the general installation of law enforcement electronics commonly installed

More information

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin LowNOx Commercial Gas Electronic Spark Ignition Sequence

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin LowNOx Commercial Gas Electronic Spark Ignition Sequence The Universal TM gas LowNOx series water heaters contain an electronic spark ignition system. The heater is connected to a 120VAC power source required by the transformer. The transformer steps down the

More information

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C C Mobile Communications 13 AMPERE POWER SUPPLY 19A704647P1-P3 CAUTION THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALI- FIED PERSONNEL ONLY. TO AVOID ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER

More information

3200NT Timer Service Manual

3200NT Timer Service Manual Service Manual Valve Serial Number Valve Position 1-LEAd 2-LAg 3-LAg 4-LAg IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specifications Sheet.....................................................................

More information

Instructions for 2-row monitoring only

Instructions for 2-row monitoring only Installation Instructions for CaseIH cotton picker models: Instructions for 2-row monitoring only Ensure the model numbers shown above correspond to the machine model. If you receive the incorrect installation

More information

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES PRODUCT SELECTION GUIDE SENTRONIC Series LCN closer/holders combine heavy duty closers with electrically controlled hold-open functions to control fire and smoke

More information

INSTALLATION MANUAL. Middle. Def tank. Standard. Middle. Standard. Def tank WARNING. Level of Difficulty CAUTION. Parts List.

INSTALLATION MANUAL. Middle. Def tank. Standard. Middle. Standard. Def tank WARNING. Level of Difficulty CAUTION. Parts List. INSTALLATION MANUAL 3025101 Level of Difficulty Moderate This is the second first of two of two manuals required to complete this installation. The first second manual manual is is included with with your

More information

BIGLA30-T/BIELA14-T Event Codes Quick Reference EXPLANATION CORRECTIVE ACTION PARTS TO CARRY ON SERVICE CALL

BIGLA30-T/BIELA14-T Event Codes Quick Reference EXPLANATION CORRECTIVE ACTION PARTS TO CARRY ON SERVICE CALL E13 TEMPERATURE PROBE FAILURE E16 HIGH LIMIT 1 EXCEEDED A. TEMP Probe reading out of range. B. Bad Connection. C. Problem with the temperatur e measuring circuitry including the probe. High limit temperature

More information

FIRE/LIFE SAFETY SERIES PRODUCT SELECTION GUIDE

FIRE/LIFE SAFETY SERIES PRODUCT SELECTION GUIDE FIRE/LIFE SAFETY SERIES PRODUCT SELECTION GUIDE SENTRONIC Series LCN closer/holders combine heavy duty closers with electrically controlled hold-open functions to control fire and smoke barrier doors.

More information

CP 634 DELUXE 4-CHANNEL KEYLESS ENTRY SYSTEM

CP 634 DELUXE 4-CHANNEL KEYLESS ENTRY SYSTEM CP 634 DELUXE 4-CHANNEL KEYLESS ENTRY SYSTEM Installation And Operation Manual MEGATRONIX VAN NUYS, CA U.S.A. CP634 1 REMOTE CONTROL CONVENIENT SYSTEM INSTALLATION & OPERATION INSTRUCTIONS INTRODUCTION

More information

JRVCS105 TROUBLESHOOTING GUIDE

JRVCS105 TROUBLESHOOTING GUIDE JRVCS105 TROUBLESHOOTING GUIDE This guide is made to ease troubleshooting the in-command system. It will cover the wiring code and where those wires are connected to the Body Control Module (BCM) and Display

More information

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD Safety Precautions Read this manual thoroughly before proceeding with installation, connections (wiring), or maintenance and inspection. Ensure you

More information

Package Unit Modulating Economizer Installation Instructions

Package Unit Modulating Economizer Installation Instructions Package Unit Modulating Economizer Installation Instructions Downflow Unit Warning: Recognize this symbol as an indication of Important Safety Information! Read all instructions prior to installation.

More information

APOLLO Gate Operators, Inc.

APOLLO Gate Operators, Inc. APOLLO Gate Operators, Inc. Model 3500ETL/3600ETL Commercial Swing Gate Operator INSTALLATION MANUAL 01/08 CONTENTS IMPORTANT SAFETY INSTRUCTIONS. 3 Applications... 4 Pre-Installation Checklist... 5 Parts

More information

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual Valcom Failsafe Unit 1620ESv2 SERIES Operation and Maintenance Manual Table of Contents Section Title Page 1. - Introduction.. 2. - Unpacking the Failsafe unit. 3. - Installation 3.1 - Auto / Timed UPS

More information

CM4200 and CM1000S Starter Control Module Installation Manual

CM4200 and CM1000S Starter Control Module Installation Manual Version Final - VF CM4200 and CM1000S Starter Control Module Installation Manual This manual is for authorized CompuStar dealers. Please thoroughly review this manual before beginning installation. If

More information

INQUIRY: HYROBOTICS CORP SAM LEE ( ) 5988 MID RIVER MALL DR. ST.CHARLES MO TEL : FAX :

INQUIRY: HYROBOTICS CORP SAM LEE (   ) 5988 MID RIVER MALL DR. ST.CHARLES MO TEL : FAX : INQUIRY: HYROBOTICS CORP SAM LEE ( Email : hanrobotic@msn.com ) 5988 MID RIVER MALL DR. ST.CHARLES MO 63304 TEL : 1-636-578-6059 FAX : 1-866-232-5594 1. Picker Body Installation 1-1. Picker Assembly. (Step

More information

INSTALLATION MANUAL. Model: PLUS Vehicle Security

INSTALLATION MANUAL. Model: PLUS Vehicle Security R Vehicle Security INSTALLATION MANUAL Model: PLUS-5000 Copyright 1999 Magnadyne Corporation For Technical Assistance (800) 638-3600 For Fax on Demand Technical Assistance (800) 994-9977 (Must be a Registered

More information

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY 0 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) / Replacement Motor Key (00KEY) Rod

More information

Service Manual Gulf Stream Electronic Full Wall Slide Systems

Service Manual Gulf Stream Electronic Full Wall Slide Systems Service Manual Gulf Stream Electronic Full Wall Slide Systems CONTENTS Page Before you operate the slide system 2 Operating Instructions 3 Preventive maintenance 3 Manually overriding your slide system

More information

650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present

650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present TOMMY GATE OWNER'S / OPERATOR'S MANUAL 650 Series 650 LB Capacity 650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present Installing the Base Plate 1. Examine the interior

More information

Applicable to the Following Part Numbers. Notes and Maintenance. Torque Specifications. Metric SAE. Use above torque setting unless otherwise noted

Applicable to the Following Part Numbers. Notes and Maintenance. Torque Specifications. Metric SAE. Use above torque setting unless otherwise noted INSTALLATION MANUAL Level of Difficulty Moderate This is the second first of two of two manuals required to complete this installation. The first second manual manual is is included with with your mounting

More information

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B Users Manual Cobra Plus Stand-By Lighting Inverter Technical Manual #018-0110-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail: techsupport@dspmanufacturing.com

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING CAUTION 80-957-00-00 (08-0) Series 570 Openings 85 to 0 or to 70 Double Lever Arm Application for Frame Reveals (76) to 7 (78mm)* Stop (Push) Side of Installation 5700 LEO Operator Installation Instructions

More information

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH

More information

Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel. Model N Installation Guide

Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel. Model N Installation Guide Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel Model 009-8004-0100N Installation Guide Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel Model 009-8004-0100N Installation Guide, Part Number 123759-3 Copyright 2011, Telect,

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL INSTALLATION & OPERATION MANUAL PRE-ASSEMBLED PRIMARY & BATTERY BACK-UP SUMP PUMP SYSTEM 5030CVSPBUSS, 5033CVSPBUSS www.aymcdonald.com A.Y. McDonald BBU Manual Revised 8-13 3210-479 Rev. A 12 This pump