Control Circuit and Load Protection Table of Contents. Control Circuit and Load Protection Devices

Size: px
Start display at page:

Download "Control Circuit and Load Protection Table of Contents. Control Circuit and Load Protection Devices"

Transcription

1 Control Circuit and Load Protection Table of Contents Control Circuit and Load Protection Devices -MC with UL and CSA Approval... Page - Bulletin -A s... Page - Bulletin -D s... Page - Bulletin -FB Fuse Holders... Page - Bulletin F Fuse Holders... Page - Bulletin -GH/GS Supplementary Protector (Miniature s)... Page - Bulletin -SP Supplementary Protector/Miniature... Page - Publication A-CAA-EN-P -

2 Bulletin Control Circuit and Load Protection Product Overview Type Bulletin -A -D -FB F Features Certifications Maximum Voltage Rating Shock Tripping Characteristic Reference Temperature Tripping Characteristic Vibration Operating Temperature Housing Material Working Voltage Leakage Current with Indicator LED Wire Size Interrupt Rating Product Selection Y/ V AC V AC Pole: V DC Pole: V DC For Class CC Fuse For Class J Fuse For Midget Fuse For Class CC Fuse or Midget Fuse For IEC x mm Fuse. A. A... A A A A A A A True IPX finger-safe design (front) A interrupt A postively trip-free mechanism (breaker operation cannot be defeated by holding the handle in the ON position) Superior shock and vibration resistance capabilties Mounts on DIN Rail IEC V AC - A interrupting Field-mountable options Optional terminal for ring lugs True IPX finger-safe design (front) A postively trip-free mechanism (breaker operation cannot be defeated by holding the handle in the ON position) Superior shock and vibration resistance capabilties Mounts on DIN Rail IEC - Field-mountable options Optional terminal for ring lugs UL Listed (CSA C. No. ), UL File Number E VDE (IEC -) Y/V AC C Curve: D Curve: Y/ V AC UL/CSA: F ( C) IEC: F ( C)... Hz for hour UL V DC IEC V DC Amplitude... Hz;. inches peak to peak;... Hz; G peak F (-...+ C), non-condensing EN/IEC Front Finger Protection Dead front construction Handle isolates the fuse from line power when it is opened for fuse insertion or removal Compact size requiring less panel space than open style fuse folders Optional blown fuse indicators - allow for easy troubleshooting of electrical circuits Type M holder - accepts A midget fuses (-/ in. x / in.) Type C holder - accepts A Class CC fuses Type J & A holders - accepts Class J fuses Silver-plated fuse clips Mounts on DIN Rail, marker-ready and increased heat dissipation UL, CSA C. No., CE, EN/IEC - V AC/DC Type M, IEC - V AC G half sine wave for ms (three axes) NA UR, CSA Lockable in the open position Compatible with Bulletin M accessories Compact busbar and connectors for Bulletin -C and -K contactors N.O./ N.C auxiliary contact late make N.O., early break N.C. UL, CSA C. No., CE, EN/IEC - V AC C Curve: ln NA NA G peak or. in. peak-to-peak displacement for hours in each perpendicular direction. Vibration sweep to to Hz ( minutes long) F (- + C) NA V AC F (- + C) Nylon Nylon V AC/DC or V AC/DC V AC/DC V AC/DC or V AC/DC. ma... mm /#... AWG Cu # AWG Cu # AWG Cu # AWG Cu # AWG Cu # AWG Cu ( mm) ka - Class CC UL/CSA: up to ka ka ka ka ka - Midget IEC: up to ka Fuse dependent Fuse dependent Page - Page - Page - Page - - Publication A-CAA-EN-P

3 Bulletin Control Circuit and Load Protection Product Overview Bulletin -MC -MCGA, -MCEA -SP Type Branch Ground Fault Detection Features /V, V & Y/V rating A interrupt / in. per pole wide... UL Circuit breaker with ground /V AC &... V AC fault circuit interrupter and ground IPX finger-safe, built-in with / in. fault equipment protector wide, add protectors for in. wide Mounts on DIN Rail or panel mount Ratings to Y/V AC, A interrupt ratings Mounts on DIN Rail Number of Poles -, -, -pole - and -pole with Neutral Maximum Voltage Tripping Characteristic Reference Temperature /V AC V AC /V AC Hz Miniature Supplementary Protector True IPX finger-safe design (front) Field mountable options for selective applications AC and DC voltage ratings in one convenient device Superior shock and vibration resistance capabilities Mounts on DIN Rail -, -, -pole -pole + neutral, -pole + neutral Y/V AC -pole V DC -pole V DC F ( C) F ( C) F ( C) Tripping Characteristic UL Standard (CSA. No..) UL/CSA Standard Certifications UL Listed (CSA. No..) UL File Number E UL, and CSA. No.. B Curve... In C Curve... In D Cruve... In UL CSA. No. VDE (IEC ) GL ( -) Dielectric Strength V AC V AC V AC Shock G half sine wave for ms ( axes) Vibration... Hz for hour... Hz for hour... Hz for hour Wire Size #.../ AWG #... AWG C (Cu only) #... AWG (... mm) Electromechanical Life UL specifications UL specifications operations Interrupt Rating V AC /V AC IEC V AC IEC - V AC UL/CSA ka U Operating Temperature (non-condensing)... F ( + C)... F ( + C) F (- + C) Product Selection Page - Page - Page - Publication A-CAA-EN-P -

4 Bulletin Control Circuit and Load Protection General Information General Information Allen-Bradley offers two lines of Miniature s with UL (CSA. No. ) certification, four different lines of Supplementary Protectors (Miniature s), and a line of fuse holders for branch circuit fuses and supplementary fuses. Product Selection Bulletin -FB Fuse Holders EN/IEC finger protection dead front construction Compact size requiring less panel space than open-style fuse holders Optional blown fuse indicator Branch circuit protection with Class CC and J fuses UL Listed, CSA Certified DIN Rail ( mm), mounted Bulletin s Potential applications include protection of: Solenoids Transformers Computers Power Supplies Relay/contactor coils PLCs Medical Equipment PLC I/O Points UL, CSA C. No. In North America, miniature circuit breakers are recognized as supplementary protectors and are intended for use as overcurrent protection within an appliance or other electrical equipment where branch circuit protection is already provided or not required. Internationally, these products are rated to IEC standards as miniature circuit breakers or circuit breakers for equipment. UL, CSA. No. In North America, some miniature circuit breakers, meeting specific requirements, may be used as Manual Motor Controllers for direct control of motors connected across-the-line equipment where branch circuit protection is already provided or not required. Internationally, these products are rated to IEC standards as miniature circuit breakers and applied for motor controller applications within those standards. UL, CSA. No.. In North America, some miniature circuit breakers, meeting specific requirements, may be used as Branch Circuit Protection devices for the protection of electric wiring as well as load protection. Type -GH -GS -SP -MC UL CSA. No.. No.. No.. No.. No. Certifications IEC EN/IEC IEC IEC IEC - IEC - CE Marked Yes Yes Yes No Yes No. of Poles,,,, +N, +N,,,, Volts AC V Y/ V Y/ V /V AC V AC Y/ V Volts DC V V p V p (series) V up to V DC Current Range. A. A. A A. A Trip Characteristics (In) G G B C D UL Standard (CSA. No..) B C, D Energy Limiting No No Yes No Yes No. of Pole/foot Varies Mounting Method DIN Rail & A-B Rail DIN Rail & A-B Rail DIN Rail DIN Rail DIN Rail IEC and Finger Protection Yes Yes Yes Varies Yes Optional Auxiliary Contacts No Yes Yes No Yes Shunt Trip No No Yes No Yes Undervoltage Trip No No Yes No Yes - Publication A-CAA-EN-P

5 Bulletin Control Circuit and Load Protection General Information Technical Information: The Benefits of Limiting Let-Through Energy Energy Limiting s Versus Conventional Breakers The Bulletin -SP line features the unique ability to achieve short circuit interruptions far more effectively than conventional circuit breakers. In conventional circuit breakers, the short circuit interruption time required is approximately one or two half cycles of an AC sine wave. When the contacts are open, the resulting arc continues to burn until the current level passes through zero. The arc may re-ignite because of the insufficient width of the contact gap. The current that flows until the arc is extinguished produces a heating effect proportional to the It value (let-through-energy) of the fault current. These devices are designed to substantially reduce the amount of let-through-current and the resulting let-through-energy that can damage protected components. They have the ability to interrupt short circuit current within the first half cycle of the fault. Limiting let-through-energy will protect against the harmful effects of over-current and is focused primarily on avoiding the following: Excessive heat Mechanical damage Both of these factors are proportional to the square of the current. Thermal energy is proportional to the square of the RMS value and magnetic forces are proportional to the square of the peak value. The most effective way to provide protection is to subtantially limit letthrough-energy.this provides the following advantages: Far less damage at the location of the short circuit. Fast electric separation of a faulty unit from the system, especially power supplies connected in parallel that are switched off when the voltage of the power bus drops below a certain level. Far less wear on the miniature circuit breaker itself. This means more safe interruptions. Better protection of all components in the short circuit path. Far wider range of selective action when used with an upstream protective device. (No nuisance shut downs from feeder line interruptions causing a blackout in all connected branches.) Short Circuit Interruption ka - V AC Instant of initiation: after voltage zero Voltage Across Breaker Max Arc Voltage Recovery Voltage Current A B C A B C A = Instant when the short is initiated B = Instant when the contacts open and the arc is initiated C = Instant when the arc extinguished and the current ceases to flow Let through t, A S, A S Publication A-CAA-EN-P -

6 Bulletin -MC Product Overview/Description Bulletin -MC s Industrial s for North American Applications The Bulletin -MC line includes: / in. wide circuit breakers in. wide circuit breakers Ground Fault Circuit Interrupters (GFCIs) Ground Fault Equipment Protector (GFEPs) Features Designed, manufactured and listed to UL (CSA C., No. ) Thermal-magnetic protection All Ratings ( A) are HACR rated kaic ( A) Finger-safe design (front) (/ in. wide) DIN Rail mounting (/ & V AC) Three-position handle (ON, Tripped (Middle), OFF) (Line and load) wire connections Table of Contents AC DIN Rail Mounting... - Specifications... - Product Selection... - Approximate Dimensions... - Certifications UL Listed CSA Certified Standards Compliance for Bul. -MC UL CSA C. No. HACR (... A) SWD ( and A) for Switching Duty for flourescent lighting applications Standards Compliance for GFCI ( ma trip sensitivity) UL CSA C. No. Bulletin -MC Thermal Magnetic Description Thermal Magnetic s Bulletin -MC s for Branch Circuit protection are available in one ()-, two ()-, and three ()-pole construction in / volt rating, volt rating and as one ()-pole and two ()- pole devices in / volt rating. Versions are available as Ground Fault Circuit Interrupters and as Ground Fault Equipment Protectors. The -MC product line consists of Thermal Magnetic Circuit Breakers and Ground Fault Sensing Breakers that are designed, manufactured, and certified to North American standards, UL, UL, UL, and the equivalent CSA standards, CSA. No..,. No.. Bul. -MC Thermal Magnetic s are generalpurpose devices suitable for the majority of industrial, inverse time circuit breaker applications. They combine thermal and magnetic trip actions and provide accurate overload and short-circuit protection for conductors and connected equipment. Application Information Selection of a Bul. -MC circuit breaker with appropriate circuit protection includes consideration of: Circuit voltage Circuit frequency Available short circuit current Continuous current rating Application considerations Special operating conditions The following discussion is based upon National Electric Code and UL requirements. Similar considerations are appropriate for Canadian applications. Circuit Voltage Bul. -MC circuit breakers are rated by voltage class. Applications should not exceed the listed voltage range (see Table ). Standards Compliance for GFEP ( ma trip sensitivity) UL CSA C. No. Circuit Frequency Bul. -MC circuit breakers may be applied to frequencies from DC up to Hz without derating. For applications above Hz, contact Rockwell Automation with specific application information for the derating of the circuit breakers. Available Short Circuit Current Bul. -MC circuit breakers should only be applied in those applications in which the available short-circuit (or fault) current is less than or equal to the interrupting rating shown in the Voltage and Interrupting Ratings table. Table. Voltage and Interrupting Ratings AC Voltage DC Voltage Interrupting Ratings (rms Symmetrical Amperes) AC Rating DC Rating Cat. No. /,,., -MCAAxx -MCAAxx -MCAAHxx,,., -MCAAxx, -MCBAxx / -MCBAxx -MCBAHxx -MCBAxx -MCEAxx / -MCEAxx, -MCGAxx / -MCGAxx Rating as supplementary protector. Consult your local Rockwell Automation sales office or Allen-Bradley distributor for specific rating. - Publication A-CAA-EN-P

7 Continuous Current Rating Bul. -MC circuit breakers are rated in RMS amperes at a C ( F) ambient temperature per UL (CSA. No..). This temperature is generally used as the average temperature within an industrial enclosure. If a circuit breaker is applied in a temperature that exceeds the C ( F) ambient, then the circuit breaker should be derated. Contact your local Rockwell Automation sales office or Allen-Bradley distributor for derating information. The characteristic trip curves are shown on pages - -. The trip bands shown for each breaker represent current tripping limits for a circuit breaker and are within the limits established by UL. For a specific current at C ( F), a circuit breaker will open ("clear the circuit") automatically at some total time that will be within the "Minimum" and "Maximum" time shown as the "Minimum" and "Maximum" curves. For example, page - shows that a one pole, A, -MC trips in not less than s and not more than s on a A current. Because the UL standard defines this time spread, users should not specify exact tripping time. The lower current portion of the curves (upper left) depict the time to trip due to thermal action and reflect overload protection of the wire and connect load. The higher current portion of the curves (lower right) depicts the trip due to magnetic action of the circuit breaker and reflects protection due to short circuit level currents. Standard current ratings are,,,,,,,,,,,,,,, and A. Application Considerations The selection of a specific ampere rating for a specific application is dependent on the type of load and duty cycle and is governed by the National Electric Code (Canadian Electric Code) and UL/CSA. In general the codes require that overcurrent protection is at the current supply and at points where wire sizes are reduced. In addition the codes state that conductors be protected according to their current carrying capacity. There are specific situations that require application consideration, such as motor circuit, and guidelines for the selection for transformer protection. Bulletin -MC circuit breakders are "non-% rated" as defined by UL Part... As such the circuit breaker's rating should be loaded to no more than %, if used with continuous loads. Bulletin -MC Product Description Branch Circuits: Bulletin -MC circuit breakers may be used to protect branch circuits. A branch circuit is the wiring portion of a system extending beyond the final overcurrent device protecting the circuit. Guidelines established in NEC, CEC, UL, and CSA should be used to determine the specific device. For example: ) Motor Branch Circuit Bulletin -MC circuit breakers are not horsepower rated because they are able to safely interrupt currents far in excess of the locked rotor value for a selected motor. This ability is recognized in the codes and standards and is also established by the UL and CSA tests described in UL and CSA C. No.. standards. The size of a Bulletin -MC circuit breaker should be determined following the guidelines for an Inverse Time. References: NEC. and UL A. Also see CEC and appropriate Canadian Standards. ) Transformer Protection Bulletin -MC circuit breakers may be used for transformer protection following the guidelines established. References: NEC and UL A. Also see CEC and appropriate Canadian Standards. ) Heater Load, Lighting, and Other Load Protection Bulletin -MC circuit breakers may be used for protection of heater loads, lighting loads, and other loads following the guidelines established. References: NEC Article and UL A. Also see CEC and appropriate Canadian Standards. Coordinated Overcurrent Protection Where an orderly shutdown is required to minimize the hazards to personnel and equipment, a system of coordination based upon the faulted or overloaded circuit is isolated by selective operation of only the overcurrent protective device closest to the overcurrent condition. The user should select devices that meet this requirement. References: NEC.. Also see CEC. Publication A-CAA-EN-P -

8 Bulletin -MC Product Description Time Current Curve -Pole Time Current Curve -MCAANN -MCEANN -MCBANN -MCGANN -pole MINUTE HOUR HOURS,,,,, (- Amp) (- Amp) CURRENT IN PERCENT OF BREAKER TRIP UNIT RATING Maximum Single-Pole Trip Times at C➀,,,, ºC Ambient ft º/ ºC Wire per Terminal Open Air,,,,,,,,,,, HOURS HOUR MINUTE Minimum Maximum TIME IN SECONDS TIME IN SECONDS Maximum Interrupting Time ,,,,, CURRENT IN PERCENT OF BREAKER TRIP UNIT RATING,,,,,. - Publication A-CAA-EN-P

9 Bulletin -MC Product Description Time Current Curve -Pole s Time Current Curve -MCAANN -MCAAHNN -MCEANN -MCBANN -MCBAHNN -MCGANN -pole s CURRENT IN PERCENT OF BREAKER TRIP UNIT RATING MINUTE HOUR HOURS,,,,,,,,,,,,,,, ºC Ambient ft º/ºC Wire per Terminal Open Air Current in All Poles,,,,, HOURS HOUR MINUTE Minimum Maximum TIME IN SECONDS TIME IN SECONDS Maximum Interrupting Time ,,,,, CURRENT IN PERCENT OF BREAKER TRIP UNIT RATING,,,,,. Publication A-CAA-EN-P -

10 Bulletin -MC Product Description Time Current Curve -Pole s MINUTE HOUR HOURS,,,,, Time Current Curve -MCAANN -MCBANN -pole s CURRENT IN PERCENT OF BREAKER TRIP UNIT RATING,,,,,,,,,, ºC Ambient ft º/ºC Wire per Terminal Open Air Current in All Phases,,,,, HOURS HOUR MINUTE Minimum Maximum TIME IN SECONDS.. TIME IN SECONDS Maximum Interuppting Time ,,,,, CURRENT IN PERCENT OF BREAKER TRIP UNIT RATING,,,,, - Publication A-CAA-EN-P

11 Bulletin -MC Cat. No. Explanation/Product Selection -MC Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all combinations will produce a valid catalog number. Code A B E G Code A a Body Style Description / in. wide/pole (DIN Rail mounting) in. wide/pole (DIN Rail mounting) GFEP ( ma) GFCI ( ma) b Interrupt Rating Description ka AIC Bul. -MC Thermal Magnetic Product Selection / and V AC DIN Rail Mounting -MC A A a b c d c Poles Code Description pole poles H poles (V AC) poles Current Rating Size Code Description Code Description A A A A A A A A A A A A A A A A / and V AC DIN Rail Mounting Cat. No. Cat. No. Width Width Continuous Ampere per pole /V AC per pole V AC C ( F) [in.] -pole -poles [in.] -poles -poles / -MCAA -MCAA / -MCAA -MCAA / -MCAAH -MCAA / -MCAA -MCAA / -MCAAH -MCAA / -MCAA -MCAA / -MCAAH -MCAA / -MCAA -MCAA / -MCAAH -MCAA / -MCAA -MCAA -MCBAH -MCBA / -MCAA -MCAA -MCBAH -MCBA / -MCAA -MCAA -MCBAH -MCBA / -MCAA -MCAA -MCBAH -MCBA / -MCAA -MCAA -MCBAH -MCBA / -MCAA -MCAA -MCBAH -MCBA -MCBA -MCBA -MCBAH -MCBA -MCBA -MCBA -MCBAH -MCBA -MCBA -MCBA -MCBAH -MCBA -MCBAA -MCBAA -MCBAHA -MCBAA -MC Ground Fault Sensing The Bulletin -MC s with Ground Fault protection for Branch Circuits are available in - and -pole construction in /V rating. Versions are available as Ground Fault Circuit Interrupters and as Ground Fault Equipment Protectors. When protection from low-level fault currents for North American standards is required, two versions of protection are available. s with protection for personnel use a threshold of ma sensing to provide protection for people. These are typically know as Ground Fault Circuit Interrupters or GFCIs. s that provide protection for equipment at a sensing threshold of ma are also available. These are typically known as Ground Fault Equipment Protectors or GFEPs. The following devices are tested and listed to meet the North American standards of UL, UL (for GFCI), UL (for GFEP), and CSA. No... It is recommended that the devices be tested monthly by using the TEST button to check for proper operation of the device. Auxiliary Devices Device description -pole - and -poles -MCAAxxx Locking Attachment for -MCBAxxx Finger protection cover for in. wide Cat. No. -MCBxxx, package of (one required for line and one required for load for each pole) (not for GFCI / GFEP) DIN Rail adapter, per pole, DIN Rail mounting for GFCI, GFEP Panel Mounting Clips for GFCI and GFEP, two required per device d -AMCAL -AMCALM -AMCBL -AMCBFP -AMCDIN -AMCP Publication A-CAA-EN-P -

12 Bulletin -MC Product Selection/Specifications Bul. -MC Ground Sensing Product Selection Specifications Terminals Cat. No. -MCAAxxx -MCBAxxx Standards Compliance UL, CSA C. No. Certifications UL Listed, CSA Certified Rated Voltage /V AC, V AC Continuous Current C ( F),,,,,,,,,,,,, Amp Rated short circuit capability ka /V AC and V AC ka Y/V AC Degree of protection Mounting Operating Temperature Shipment and short term storage limits Wire Size Terminal Torque Recommended Wire Strip Length Cat. No. Cat. No. Continuous Ampere C ( F) [A] V AC /V AC -pole -pole GFCI ( ma Sensitivity) -MCGA -MCGA -MCGA -MCGA -MCGA -MCGA -MCGA -MCGA -MCGA -MCGA -MCGA GFEP ( ma Sensitivity) -MCEA -MCEA -MCEA -MCEA -MCEA -MCEA -MCEA -MCEA -MCEA -MCEA -MCEA For panel mounting use two -AMCP per device For DIN Rail mounting use one -AMCDIN per pole Open Device / in. wide circuit breakers are finger safe from front per IEC. Terminal Covers available for in. wide circuit breaker at / and V AC. DIN Rail (check product for specific) C (... F) (non-condensing) - C + C (-... F) See Terminals Table Below Continuous Current Rating Wire Type Wire Range [AWG] Terminal Torque Line Strip Length Line and Load Terminals A A A / lb in (. N m) lb in (. N m) lb in (. N m) lb in (. N m) lb in (. N m) lb in (. N m) / in. / in. Allen Head Copper (Cu) lb in (. N m) / in. Line -MCEAxxx A lb in (. N m) Load -MCGAxxx lb in (. N m) - Publication A-CAA-EN-P

13 Bulletin -MC Approximate Dimensions -MC Approximate Dimensions Note: Dimensions are shown in inches (millimeters). Dimensions are not intended for manufacturing purposes. Catalog Type No. of Poles Continuous Current Rating [A] Width [in.] -MCAAxx. -MCAAxx. -MCAAHxx. -MCAAxx. -MCBAxx.... -MCBAxx.... -MCBAHxx.... -MCBAxx.... -MCEAxx.... -MCEAxx.... -MCGAxx.... -MCGAxx.... -MCAAnxx. (.). (.) -MCEAxx -MCGAxx Line End View. (.). (.). (.). (.). (.). (.). (.). (.). (.) Width. (.) On. (.). (.) Radius Off Reset. (.) Trip. (.). (.) Terminal #-. (.). (.). (.). (.). (.). (.) DIN Rail Mounting Location. (.). (.). (.) Front View. (.). (.). (.). (.) Radius. (.) On Off Reset. (.). (.). (.) Trip. (.). (.). (.). (.) Side View. (.). (.). (.). (.). (.). (.). (.) Ground Neutral Wire Length. inches (.) Publication A-CAA-EN-P -

14 Bulletin -MC Approximate Dimensions -MCEAxx -MCGAxx Line End View. (.) Front View. (.). (.). (.). (.). (.). (.). (.). (.). (.). (.) A thru A style Radius. (.) On Off Reset. (.). (.) Trip Side View. (.). (.). (.). (.). (.) Bottom View. (.). (.). (.) Ground Neutral Wire Length. inches (.) -MCBAxxx. (.). (.). (.). (.). (.). (.) - Publication A-CAA-EN-P

15 Bulletin -A Product Overview/Description Industrial s for North American Applications Energy limiting design - protects downstream components better than conventional breakers during short circuits Field mountable options for selective applications IPx Finger-Protection (Front) North America certifications: UL, CSA. No. International standards: CE Marked, and IEC (VDE) standards for worldwide acceptance Ratings: UL/CSA max. Y/V AC up to ka interrupt rating; IEC max. /V AC A interrupt rating V DC rating, V DC -pole series A positively trip-free mechanism (breaker operation cannot be defeated by holding the handle in the ON position) Trip curves: C and D Time delay (D Characteristic) for high inrush currents during inductive start-ups such as motors, transformers and power supplies Superior shock and vibration resistance capabilities helps to prevent nuisance tripping Mounts on DIN Rail Wire connect, line and load (reversible) Optional terminals for ring lug terminals. The Bulletin -A line includes: UL, CSA C. No. V AC... A V/V AC... A Miniature for EN/IEC Applications EN/IEC - V AC... A SWD (... A) Switching Duty for fluorescent lighting applications HACR -pole V DC. A -pole (series) V DC. A V DC. A Bulletin -A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable options for selective applications IPx Finger-Protection (Front) North America certifications: UL, CSA C. No. International standards: CE Marked, and IEC (VDE) standards for worldwide acceptance Ratings: UL/CSA max. Y/V AC up to ka interrupt rating; IEC max. /V AC A interrupt rating V DC rating, V DC -pole series A positively trip-free mechanism (breaker operation cannot be defeated by holding the handle in the ON position) Trip curves: C and D Time delay (D Characteristic) for high inrush currents during inductive start-ups such as motors, transformers and power supplies Superior shock and vibration resistance capabilities helps to prevent nuisance tripping Mounts on DIN Rail Wire connect, line and load (reversible) Optional terminals for ring lug terminals Table of Contents Description... this page Product Selection... - Specifications... - Approximate Dimensions... - Miniature for IEC Applications: V AC... A Standards Compliance UL CSA C. No. EN/IEC - Certifications UL Listed CSA Certified CE Marked VDE Certified Features Designed manufactured and listed to UL (CSA. No. ) Thermal-magnetic protection All ratings are HACR rated up to ka Interrupting rating Finger safe design (front) DIN Rail mounting Line and load wire connections Optional ring terminal connections (convertible) Description Bulletin -A s for Branch Circuit protection are available in -, -, and -pole construction and are rated... A at V AC and... A at Y/V AC for North American applications (UL and CSA C. No. ). The circuit breakers also have a -pole V DC, -pole (series) V DC rating. For EN\IEC applications the products are rated V AC, V AC... A. Thermal Magnetic s The Bulletin -A Thermal Magnetic s are generalpurpose devices suitable for the majority of industrial, inverse time circuit breaker applications. They combine thermal and magnetic trip actions and provide accurate overload and short-circuit protection for conductors and connected equipment. Publication A-CAA-EN-P -

16 Bulletin -A Product Description Application Information Selection of a Bulletin circuit breaker with appropriate circuit protection includes consideration of: Circuit voltage Circuit frequency Available short circuit current Continuous current rating Application considerations Special operating conditions The following discussion is based upon National Electric Code and UL requirements. Similar considerations are appropriate for Canadian applications. Circuit Voltage The Bulletin -A circuit breakers are rated by voltage class. Applications should not exceed the listed voltage and current range (see Table ). Circuit Frequency The Bulletin -A circuit breakers may be applied to frequencies of Hz and Hz without derating. For applications above Hz, contact Rockwell Automation with specific application information for the derating of the circuit breakers. Available Short Circuit Current The Bulletin -A circuit breakers should only be applied in those applications in which the available short-circuit (or fault) current is less than or equal to ka... ka (US/Canada) and ka (IEC). Table. Voltage and Current Ranges Region Max. Voltage Current Range [A] EN/IEC Regions North America (UL & CSA C. No. ) V AC... V DC... V AC... Y/V AC... -pole V DC... -pole V DC... Continuous Current Rating Standard current ratings are:.,,.,,,,,,,,,,,,,,,, and A. The Bulletin -A circuit breakers are rated in RMS amperes at a C ( F) ambient temperature per the UL (CSA. No. ) standard. This temperature is generally used as the average temperature within an industrial enclosure. If a circuit breaker is applied in a temperature that exceeds the C ( F) ambient, then the circuit breaker should be derated. For IEC - standard, the products carry an ambient rating of C. Follow standard IEC application considerations for temperature rating in different ambient temperatures. The characteristic trip curves are shown on page -. The trip bands shown for each breaker represent current tripping limits for a circuit breaker and are within the limits established by UL. For a specific current at C ( F), a circuit breaker will open ("clear the circuit") automatically at some total time that will be within the "Minimum" and "Maximum" time shown on the curves. For example, page - shows that a one-pole, A, Bulletin -A circuit breaker trips in not less than s and not more than s on a A current. Because the UL standard defines this time spread, users should not specify exact tripping time. The lower current portion of the curves (upper left) depict the time to trip due to thermal action and reflect overload protection of the wire and connect load. The higher current portion of the curves (lower right) depicts the trip due to magnetic action of the circuit breaker and reflects protection due to short circuit level currents. Application Considerations The following is a discussion of application considerations related to North American applications. When applying product to IEC regional requirements, follow IEC practices and guidelines. The selection of a specific ampere rating for a specific application is dependent on the type of load and duty cycle and is governed by the National Electric Code (Canadian Electric Code) and UL/CSA. In general, the codes require that overcurrent protection is at the current supply and at points where wire sizes are reduced. In addition, the codes state that conductors be protected according to their current carrying capacity. There are specific situations that require application consideration, such as motor circuit, and guidelines for the selection for transformer protection. The Bulletin -A circuit breakers are non percent rated as defined by UL, para... As such, the circuit breaker's rating should be loaded to no more than % if used with continuous loads. Line and load may be reversed. The Bulletin circuit breaker may be bottom fed. Branch Circuits: Bulletin -A circuit breakers may be used to protect branch circuits. A branch circuit is the wiring portion of a system extending beyond the final overcurrent device protecting the circuit. Guidelines established in NEC, CEC, UL, and CSA should be used to determine the specific device. For example: ) Motor Branch Circuit Bulletin -A circuit breakers are not horsepower rated because they are able to safely interrupt currents far in excess of the locked rotor value for a selected motor. This ability is recognized in the codes and standards and is also established by the UL and CSA tests described in UL and CSA C. No. standards. The size of a Bulletin circuit breaker should be determined following the guidelines for an Inverse Time. References: NEC. and UL. Also see CEC and appropriate Canadian Standards. ) Transformer Protection Bulletin -A circuit breakers may be used for transformer protection following the guidelines established. References: NEC and UL. Also see CEC and appropriate Canadian Standards. ) Heater Load, Lighting, and Other Load Protection Bulletin -A circuit breakers may be used for protection of heater loads, lighting loads, and other loads following the guidelines established. References: NEC Article and UL A. Also see CEC and appropriate Canadian Standards. Coordinated Overcurrent Protection Where an orderly shutdown is required to minimize the hazards to personnel and equipment, a system of coordination based upon the faulted or overloaded circuit is isolated by selective operation of only the overcurrent protective device closest to the overcurrent condition. The user should select devices that meet this requirement. References: NEC.. Also see CEC. - Publication A-CAA-EN-P

17 HACR Rating Bulletin -A s are rated as Heating, Air Conditioning and Refrigeration circuit breakers as defined by UL, paragraph. and may used in this type of application. SWD Rating The Bulletin breakers (. A) are rated as SWD and as such may be applied to switch fluorescent lighting loads up to their current and voltage maximum. Current Limiting Bulletin -A s are rated as current limiting circuit breakers as defined by UL, paragraph.. The Bulletin -A line features the ability to achieve short circuit interruptions far more effectively than conventional breakers. In conventional circuit breakers, the short circuit interruption time required is approximately one or two half cycles of an AC sine wave. When the contacts open, the resulting arc continues to burn until the current level passes through zero. The arc may re-ignite because of the insufficient width of the contact gap. The current that flows until the arc is extinguished produces a heating effect proportional to the It value (let-through-energy) of the fault current. The Bulletin -A device is designed to substantially reduce the amount of let-through-current and the resulting let-through-energy that can damage protected components. The Bulletin has the ability to interrupt short circuit current within the first half cycle of the fault. Limiting let-through current and energy will protect against the harmful effects of overcurrent and is focused primarily on avoiding the following: Excessive Heat Mechanical Damage Both of these factors are proportional to the square of the current. Thermal energy is proportional to the square of the RMS value and magnetic forces are proportional to the square of the peak value. The most effective way to provide protection is to substantially limit let-through-energy. This provides the following advantages Far less damage at the location of the short circuit. Fast electric separation of a faulty unit from the system, especially power supplies connected in parallel that are switched off when the voltage of the power bus drops below a certain level. Far less wear on the miniature circuit breaker itself. This means more safe interruptions. Better protection of all components in the short circuit path. Far wider range of selective action when used with an upstream protective device. (No nuisance shut downs from feeder line interruptions, causing a blackout in all connected branches.) The following values are applicable to the whole product range with frequency of / Hz. The values were derived from worst case V AC testing of: D trip A, V ka D trip A, Y/V ka D trip A, Y/V ka Current-Limiting at V / kap, p, p It = ka²s and I peak =. ka Current-Limiting at Y/V / ka p, p, p It = ka²s and I peak =. ka Current-Limiting at Y/V / ka p, p, p It = ka²s and I peak =. ka Bulletin -A Product Description Bulletin -A Ambient Temperature Derating The standard tripping characteristic for Bulletin -A is Type C. Type C has a magnetic trip activated at times the rated current of the circuit breaker. The reference temperature for the thermal tripping characteristics is C. The Type C characteristic will suit most applications. In rare occurrences when the Type C characteristic does not fully meet the application, the following additional magnetic trip characteristic is available: Type D allows for transients approximately twice as high as the standard Type C. Use the following table and graph to determine the current rating for the breaker if the ambient is significantly different than C. Bulletin -A Ambient Temperature Derating Calibration Temperature º C (UL) Application below º C is for non-condensing atmosphere Device Marked Current Rating C Ambient Temperature ( C) Care should be taken for application below C. These devices are not certified to operate correctly in the presence of ice. All other specifications for standard Bulletin -A products remain unchanged. The ambient temperature derating applies to applications of the device as an IEC Miniature (MCB), following - and as Circuit Breaker to UL/CSA. No.. Ambient temperature refers to the free air temperature in contact with the device Publication A-CAA-EN-P -

18 Bulletin -A Product Description Ambient Temperature Graph Load Factor K T [I/I n ] Influence of Ambient Temperature (T) on Load-Carrying Capacity - - Ambient Temperature T [ C] Maximum load I at Ambient Temperature T: L I (T) = I K (T) The -A circuit breaker can function over a wide temperature range (-...+ C). Operation in ambient temperatures below C is based on a non condensing atmosphere (no ice). Use the graph above or contact your local Rockwell Automation sales office or Allen-Bradley distributor to determine the correction factor based upon ambient temperature. L n T Terminals Standard wire (cable) connection The standard configuration of the Bulletin -A is with terminals suitable for connection of stranded copper wire of the wire size # AWG (. mm). Strip length for the termination is. in. ( mm). Terminals are shipped in the open position for ease of installation. Optional Ring Termination For the Bulletin -A circuit breakers, an optional terminal configuration (suffix R) is available for use with a ring terminal. This configuration is shipped so that the terminal screw may be unscrewed and withdrawn for the insertion of the ring terminal at proper connection point. The screw is then retightened to provide proper wire termination. This unique terminal may be field converted to open the wire termination to allow standard wire termination of the converted terminal. Bus Bars For the Bulletin -A circuit breakers, UL Recognized bus bars and UL Listed feeder terminals are available for group connection of circuit breakers. They are available in -, -, and - pole configurations for connection of multiple circuit breakers. Lock-out Attachment A sturdy lock-out attachment may be added to a circuit breaker. This lock-out may be padlocked so that the circuit breaker is locked in the off position. Shunt Trip A shunt trip may be added to a circuit breaker to allow the device to be tripped from a remote source. One version is for tripping voltages of V AC ( V DC) and another for tripping voltages of V AC ( V DC). Auxiliary Contacts An auxiliary contact module may be added to a circuit breaker to provide pilot duty contacts to indicate the position of circuit breaker, off or on. This contact changes state when the circuit breaker is operated either manually or electrically. Signal Contacts A signal/auxiliary contact module may be added to a circuit breaker to provide auxiliary contact information off and on and signal contact pilot duty contacts. With signal contacts, the contacts change state only when the circuit breaker changes state from On to Off because of an electrical operation. The module contains one signal contact, form C contact (N.O. and N.C contact with common) and one auxiliary contact (N.O. and N.C contact with common). - Publication A-CAA-EN-P

19 Bulletin -A Product Description Time Current Curve -, -, and -Pole Time-Current Characteristic Bulletin Type C and D Ambient Temperature C Tripping characteristic acc. to UL Conventional non-tripping current I =. I (T= C) nt Conventional tripping current I =. I : t < h (T= C) N t N N. I : t = - s (T= C) instantaneous tripping acc. to IEC - t [sec] Type C: I N : t >. s I : t <. s Type D: I N : t >. s I : t <. s N N.... C D I / I N Publication A-CAA-EN-P -

20 Bulletin -A Cat. No. Explanation Bulletin Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all combinations will produce a valid catalog number. Code A D Code a Body Style Description Standard configuration, AC Device Standard configuration, DC Device b Poles Description -Pole -Pole -Pole Code B C D c Trip Curve Trip Curve Trip Curve B Trip Curve C Trip Curve D - A C R Code a b c d e d Rated Current (I n ) Current [A].. Code blank R e Factory Modifications Description Standard Terminal Ring Terminal - Publication A-CAA-EN-P

21 Bulletin -A Product Selection Product Selection Bulletin -A AC Miniature s Bulletin -Pole AC Miniature s No. of Poles EN/IEC Maximum Voltage Trip Curve UL/CSA Max. Volt. Rated Current [A] V AC, V DC C D V AC, V DC V AC, V DC V AC, V DC V AC, V DC Standard Wire Configuration Cat. No. Ring Terminal Configuration Cat. No.. -AC -ACR -AC -ACR. -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR. -AD -ADR -AD -ADR. -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR Publication A-CAA-EN-P -

22 Bulletin -A Product Selection Bulletin -A -Pole AC Miniature s No. of Poles EN/IEC Maximum Voltage Trip Curve UL/CSA Max. Volt. Rated Current [A] V AC C D Y/V AC, V DC V AC, V DC Y/V AC, V DC V AC, V DC Standard Wire Terminal Cat. No. Ring Terminal Configuration Cat. No.. -AC -AC -AC -ACR. -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR. -AD -ADR -AD -ADR. -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR - Publication A-CAA-EN-P

23 Bulletin -A Product Selection Bulletin -A -Pole AC Miniature s No. of Poles EN/IEC Maximum Voltage Trip Curve UL/CSA Max. Volt. Rated Current [A] V AC C D Y/V AC V AC Y/V AC V AC Standard Wire Terminal Cat. No. Ring Terminal Configurations Cat. No.. -AC -ACR -AC -ACR. -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR -AC -ACR. -AD -ADR -AD -ADR. -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR -AD -ADR Publication A-CAA-EN-P -

24 Bulletin -A Accessories Miniature Accessories IEC - Description CSA/UL Certifications Compliance CE EN/IEC Max. Volt. UL/CSA Max. Volt. Connection Cat. No. Lockout Attachment Yes Yes -AALOA Auxiliary Contact, sets, each are Form C, N.O. & N.C. Auxiliary/Signal Contact, each are Form C, N.O. & N.C Auxiliary Contact, Feed Through, N.O. & N.C. Yes Yes Yes Yes Yes Yes A, V AC (AC). A, V DC A, V AC (AC). A, V DC A, V AC (AC). A, V DC A, V AC. A, V DC A, V AC. A, V DC A, V AC. A, V DC Cable -AAHH Cable -AAHS Cable -ABH Shunt Trip Module Yes Yes Shunt Trip Module Yes Yes...V AC V DC...V AC V DC...V AC V DC...V AC V DC Use of auxiliary or signal contact limits the -A circuit breaker to a maximum voltage of V AC for UL/CSA applications. Use of this auxiliary contact allows application of the -A circuit breaker to full rating of Y/ V AC for UL/CSA applications. Cable Cable -AASTA -AASTA Bulletin -A Bus Bar Description No. of Poles No. of Phases Pkg Qty. Number of s Cat. No. -AACL -AACL -AACL -AACL Bus Bar -AACL -AACL -AACL -AACL UL Recognized (E), CE Marked Bulletin Bus Bar Accessories -AACL Description No. of Poles Pkg Qty. Wire Range Cat. No. Terminal Lug -pole for circuit breaker termination Protective Cover for Unused Termination # AWG. mm -AACLT -pole set (may be separated) -AACLPS - Publication A-CAA-EN-P

25 Bulletin -A Specifications Bulletin -A Specifications Number of Poles,, and Standards UL CSA C. No. EN/IEC - Certifications UL Listed (File Number E) CSA Certified, VDE Certified, MCB, CE Marked HACR Rating (USA/Canada) Yes SWD Rating (USA/Canada) Yes (... A) Calibration Temperature UL/CSA: C EN/IEC: C Rated Interrupting Capacity Rated Tripping Current Degree of Protection Dielectric Strength Shock Vibration Normal Operating Environment EN/IEC - Icu: A UL/CSA (See Below) Trip Curve Rated Current (In) Interrupt Rating (UL/CSA) C Curve D Curve... A, A... A, A... A, A... A, A... A, A... A, A UL/CSA:... A, Y/V AC... A, V AC. A V DC -pole. A V DC -pole EN/IEC:... A, V AC V DC Finger-safe from front: -IP per IEC from front -IP at wire terminals V AC G Half sine wave for ms ( axes) Frequency range: Hz Max. amplitude (p-p) =. in. Max. acceleration = G hours each of axes - + C (-... F) (non-condensing) Trip Curves Shipment and Short-Term Storage Limits Wire Size Terminal Torque Recommended Wire Strip Length C curve (Inductive)... I N D curve (Highly Inductive)... I N C (-...+ F) wire: #... AWG wires: #... AWG #... AWG: lb in #... AWG: lb in # AWG: lb in # PoziDriv. in. Publication A-CAA-EN-P -

26 Bulletin -A Approximate Dimensions Bulletin -A Approximate Dimensions Note: All units are in millimeters unless indicated. Dimensions are not intended for manufacturing purposes. Catalog Number Without R Suffix With R Suffix Line/Load Terminal Style Cable Ring Lug Note: Dimensions are in millimeters (mm). Access Hole Dia. in Housing (mm).. Terminal Screw Head Diam (mm) Comment: Terminal Screw Type Non-Removable # Removable PoziDrive - Publication A-CAA-EN-P

27 Bulletin -A Approximate Dimensions Note: All units are in millimeters unless indicated. Dimensions are not intended for manufacturing purposes. Terminal Screw/Clamp Mounting Screws -AAHH & -AAHS -ABH -AAST, -AAST Publication A-CAA-EN-P -

28 Bulletin -A Approximate Dimensions Note: All units are in millimeters unless indicated. Dimensions are not intended for manufacturing purposes. Surfaces Nominally Flush (in the same plane) Maximum. (out of plane) -AACL Surfaces Nominally Flush (in the same plane) Maximum. (out of plane) -AACL Surfaces Nominally Flush (in the same plane) Maximum. (out of plane) -AACL Surfaces Nominally Flush (in the same plane) Maximum. (out of plane) -AACL - Publication A-CAA-EN-P

29 Bulletin -A Approximate Dimensions Note: All units are in millimeters unless indicated. Dimensions are not intended for manufacturing purposes. Surfaces Nominally Flush (in the same plane) Maximum. (out of plane) -AACL Surfaces Nominally Flush (in the same plane) Maximum. (out of plane) -AACL Surfaces Nominally Flush (in the same plane) Maximum. (out of plane) -AACL Surfaces Nominally Flush (in the same plane) Maximum. (out of plane) -AACL Publication A-CAA-EN-P -

30 Bulletin -A Approximate Dimensions Note: All units are in millimeters unless indicated. Dimensions are not intended for manufacturing purposes. Surfaces Nominally Flush (in the same plane) Maximum. (out of plane) -AACL, Cat -AACLT Ser. A See instruction sheet - IEC:, - mm² UL: # - AWG. In E mm UL,, -AACLT,,,, -AACLPS B L A C K P R I NT I N G - Publication A-CAA-EN-P

31 Bulletin -D Product Overview/Description Bulletin -D s Specially designed for higher voltage DC circuits with a permanent magnet to direct the arc into the arc splitters. Field-mountable options for selective applications IPx Finger-Protection (Front) North America certifications: UL, CSA C. No. International standards: CE Marked for IEC - standards for worldwide acceptance ka interrupt rating UL/CSA pole: max. V DC, pole: max. V DC IEC pole: max. V DC, pole: max. V DC A positively trip-free mechanism (breaker operation cannot be defeated by holding the handle in the ON position) Trip curves: C Superior shock and vibration resistance capabilities helps to prevent nuisance tripping Mounts on DIN Rail Wire connect, follow polarity requirements Table of Contents Description this page Product Selection - Specifications - Approximate Dimensions - Industrial s for North American Applications Field mountable options for selective applications IPx Finger-Protection (Front) North America certifications: UL, CSA. No. International standards: CE Marked for IEC - standards for worldwide acceptance ka interrupt rating UL/CSA pole: max. V DC, pole: max. V DC IEC pole: max. V DC, pole: max. V DC A positively trip-free mechanism (breaker operation cannot be defeated by holding the handle in the ON position) Trip curves: C Superior shock and vibration resistance capabilities helps to prevent nuisance tripping Mounts on DIN Rail Wire connect, line and load (reversible) Follow polarity requirements. The Bulletin -D line includes: UL, CSA C. No. pole, V DC,... A pole, V DC,... A Miniature for EN/IEC Applications EN/IEC - pole, V DC,... A pole, V DC,... A Miniature for IEC Applications: pole, V DC,... A pole, V DC,... A Standards Compliance UL CSA C. No. EN/IEC - Certifications UL Listed CSA Certified CE Marked Features Designed manufactured and listed to UL (CSA. No. ) Thermal-magnetic protection up to ka Interrupting rating Finger safe design (front) DIN Rail mounting Line and load wire connections Follow polarity requirements Publication A-CAA-EN-P -

32 Bulletin -D Product Description Description Bulletin -D s for Branch Circuit protection are available in - and -pole construction and are rated... A at V DC and... A at V DC for North American applications (UL and CSA C. No. ).. For EN\IEC applications the products are rated -pole:... A, V DC, and -pole:... A, V DC. Thermal Magnetic s The Bulletin -D Thermal Magnetic s are generalpurpose devices suitable for the majority of industrial, inverse time circuit breaker applications. They combine thermal and magnetic trip actions and provide accurate overload and short-circuit protection for conductors and connected equipment. Application Information Selection of a Bulletin -D circuit breaker with appropriate circuit protection includes consideration of: Circuit voltage Available short circuit current Continuous current rating Application considerations Special operating conditions Regional certifications The following discussion is based upon National Electric Code and UL requirements. Similar considerations are appropriate for Canadian and IEC applications. Circuit Voltage The Bulletin -D circuit breakers are rated by voltage class. Applications should not exceed the listed voltage and current range (see Table ). Available Short Circuit Current The Bulletin -D circuit breakers should only be applied in those applications in which the available short-circuit (or fault) current is less than or equal to ka. Table. Voltage and Current Ranges Region EN/IEC Regions North America (UL & CSA C. No. ) Max. Voltage Current Range [A] -pole V DC... -pole V DC... -pole V DC... -pole V DC... Continuous Current Rating Standard current ratings are:,,,,,,,,,,,,,,, and A. The Bulletin -D circuit breakers are rated in amperes at a C ( F) ambient temperature per the UL (CSA. No. ) standard. This temperature is generally used as the average temperature within an industrial enclosure. If a circuit breaker is applied in a temperature that exceeds the C ( F) ambient, then the circuit breaker should be derated. For IEC - standard, the products carry an ambient rating of C. Follow standard IEC application considerations for temperature rating in different ambient temperatures. The characteristic trip curve is shown on page -. The trip bands shown for each breaker represent current tripping limits for a circuit breaker and are within the limits established by UL. For a specific current at C ( F), a circuit breaker will open ("clear the circuit") automatically at some total time that will be within the "Minimum" and "Maximum" time shown on the curves. For example, page - shows that a one-pole, A, Bulletin circuit breaker trips in not less than s and not more than s on a A current. Because the UL standard defines this time spread, users should not specify exact tripping time. The lower current portion of the curves (upper left) depict the time to trip due to thermal action and reflect overload protection of the wire and connect load. The higher current portion of the curves (lower right) depicts the trip due to magnetic action of the circuit breaker and reflects protection due to short circuit level currents. Application Considerations The following is a discussion of application considerations related to North American applications. When applying product to IEC regional requirements, follow IEC practices and guidelines. The selection of a specific ampere rating for a specific application is dependent on the type of load and duty cycle and is governed by the National Electric Code (Canadian Electric Code) and UL/CSA. In general, the codes require that overcurrent protection is at the current supply and at points where wire sizes are reduced. In addition, the codes state that conductors be protected according to their current carrying capacity. There are specific situations that require application consideration, such as motor circuit, and guidelines for the selection for transformer protection. The Bulletin -D circuit breakers are non percent rated as defined by UL, para... As such, the circuit breaker's rating should be loaded to no more than % if used with continuous loads. Polarity Positive and negative connection many not be reversed. Branch Circuits Bulletin circuit breakers may be used to protect branch circuits. A branch circuit is the wiring portion of a system extending beyond the final overcurrent device protecting the circuit. Guidelines established in NEC, CEC, UL, and CSA should be used to determine the specific device. Coordinated Overcurrent Protection Where an orderly shutdown is required to minimize the hazards to personnel and equipment, a system of coordination based upon the faulted or overloaded circuit is isolated by selective operation of only the overcurrent protective device closest to the overcurrent condition. The user should select devices that meet this requirement. References: NEC.. Also see CEC. - Publication A-CAA-EN-P

33 Determining Ratings The tripping characteristic for Bulletin -D is Type C. Type C has a magnetic trip activated at times the rated current of the circuit breaker. The reference temperature for the thermal tripping characteristics is C ( F). The Type C characteristic will suit most applications. Use the following table and graph to determine the current rating for the breaker if the ambient is significantly different than C ( F). Ambient Temperature Graph.. Influence of Ambient Temperature (T) on Load-Carrying Capacity Bulletin -D Product Description Bulletin -D Ambient Temperature Derating Calibration Temperature º C (UL) Application below º C is for non-condensing atmosphere Load Factor K T [I/I n ].... Device Marked Current Rating C Care should be taken for application below C ( F). These devices are not certified to operate correctly in the presence of ice. All other specifications for standard Bulletin -A products remain unchanged. The ambient temperature derating applies to applications of the device as an IEC Miniature (MCB), following - and as Circuit Breaker to UL/CSA. No.. Ambient temperature refers to the free air temperature in contact with the device - - Ambient Temperature T [ C] Maximum load I at Ambient Temperature T: L I (T) = I K (T) L The -D circuit breaker can function over a wide temperature range (-...+ C). Operation in ambient temperatures below C is based on a non condensing atmosphere (no ice). Use the graph above or contact your local Rockwell Automation sales office or Allen-Bradley distributor to determine the correction factor based upon ambient temperature. Terminals Standard wire (cable) connection The standard configuration of the Bulletin is with terminals suitable for connection of stranded copper wire of the wire size # AWG (. mm). Strip length for the termination is. in. ( mm). Terminals are shipped in the open position for ease of installation. Lock-out Attachment A sturdy lock-out attachment may be added to a circuit breaker. This lock-out may be padlocked so that the circuit breaker is locked in the off position. Shunt Trip A shunt trip may be added to a circuit breaker to allow the device to be tripped from a remote source. One version is for tripping voltages of V AC ( V DC) and another for tripping voltages of V AC ( V DC). Auxiliary Contacts An auxiliary contact module may be added to a circuit breaker to provide pilot duty contacts to indicate the position of circuit breaker, off or on. This contact changes state when the circuit breaker is operated either manually or electrically. Signal Contacts A signal/auxiliary contact module may be added to a circuit breaker to provide auxiliary contact information off and on and signal contact pilot duty contacts. With signal contacts, the contacts change state only when the circuit breaker changes state from On to Off because of an electrical operation. The module contains one signal contact, form C contact (N.O. and N.C contact with common) and one auxiliary contact (N.O. and N.C contact with common). n T Publication A-CAA-EN-P -

34 Bulletin -D Product Description Time Current Curve - and -Pole Time-Current Characteristic UL Tripping Characteristic acc. to UL conventional non-tripping current I nt =. I n conventional tripping current I =. I n : t < h t Tripping time t [sec]..... C. I n : t = - s I n : t >. s I n : t <. s..... I / I n - Publication A-CAA-EN-P

35 Bulletin -D Product Overview/Description Bulletin Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all combinations will produce a valid catalog number. Code A D Code a Body Style Description Standard configuration, AC Device Standard configuration, DC Device b Poles Description -pole -pole Code C c Trip Curve Trip Curve Trip curve C - D C Code a b c d e d Rated Current (I n ) Current [A] Code blank R e Factory Modifications Description Standard terminal Ring terminal (available on -A only) Publication A-CAA-EN-P -

36 Bulletin -D Product Selection/Accessories Product Selection Bulletin DC Miniature s Bulletin -D, -Pole DC Miniature s No. of Poles EN/IEC Maximum Voltage Trip Curve UL/CSA Max. Volt. Rated Current [A] Standard Wire Configuration Cat. No. C V DC Bulletin -D, -Pole AC Miniature s -DC -DC -DC -DC -DC -DC -DC -DC -DC -DC -DC -DC -DC -DC -DC -DC -DC No. of Poles EN/IEC Maximum Voltage Trip Curve UL/CSA Max. Volt. Rated Current [A] Standard Wire Configuration Cat. No. V DC C V DC Miniature Accessories -DC -DC -DC -DC -DC -DC -DC -DC -DC -DC -DC -DC -DC -DC -DC -DC -DC IEC - Description CSA/UL Certifications Compliance CE EN/IEC Max. Volt. UL/CSA Max. Volt. Connection Cat. No. Lockout Attachment Yes Yes -AALOA Auxiliary Contact, sets, each are Form C, N.O. & N.C. Auxiliary/Signal Contact, each are Form C, N.O. & N.C Auxiliary Contact, Feed Through, N.O. & N.C. Yes Yes Yes Yes Yes Yes A, V AC (AC). A, V DC A, V AC (AC). A, V DC A, V AC (AC). A, V DC A, V AC. A, V DC A, V AC. A, V DC A, V AC. A, V DC Cable Cable Cable -AAHH -AAHS -ABH Shunt Trip Module Yes Yes Shunt Trip Module Yes Yes...V AC V DC...V AC V DC...V AC V DC...V AC V DC Cable Cable -AASTA -AASTA - Publication A-CAA-EN-P

37 Bulletin -D Specifications/Approximate Dimensions Bulletin -D Specifications Number of Poles and Standards UL CSA C. No. EN/IEC - Certifications UL Listed (File Number E) CSA Certified, VDE Certified, MCB, CE Marked SWD Rating (USA/Canada) Yes (... A) Calibration Temperature UL/CSA: C EN/IEC: C Rated Interrupting Capacity Rated Tripping Current Degree of Protection Dielectric Strength Shock Vibration Normal Operating Environment Trip Curves Shipment and Short-Term Storage Limits Wire Size Terminal Torque Recommended Wire Strip Length EN/IEC - Icu: A UL/CSA ka UL/CSA:... A, -pole VAC... A, -pole VAC EN/IEC:... A, -pole VAC... A, -pole VAC Finger-safe from front: -IP per IEC from front -IP at wire terminals V AC G Half sine wave for ms ( axes) Frequency range: Hz Max. Amplitude (p-p) =. in. Max. Acceleration = G hours each of axes - + C (-...+ F) (non-condensing) C curve (Inductive)... I N C (-...+ F) wire: #... AWG wires: #... AWG #... AWG: lb in #... AWG: lb in # AWG: lb in # PoziDriv. in. Bulletin -D Approximate Dimensions Note: All units are in millimeters unless indicated. Dimensions are not intended for manufacturing purposes. Publication A-CAA-EN-P -

38 Bulletin -D Approximate Dimensions Note: All units are in millimeters unless indicated. Dimensions are not intended for manufacturing purposes. -ABH -AAST, -AAST Terminal Screw/Clamp Mounting Screws -AAHH & -AAHS - Publication A-CAA-EN-P

39 Bulletin -FB Fuse Holders Product Overview/Selection Bulletin -FB DIN Rail Mounting Fuse Holders Compact size requiring less panel space than open-style fuse holders Handle isolates the fuse from power when installing or removing fuse IP Front-finger protection per IEC/EN Optional blown fuse indicators allow easy troubleshooting of electrical circuits Easy insertion/removal of fuses, no special tools required Mounts on standard mm DIN Rail Marker-ready Terminals shipped in open position and are ready for wiring Table of Contents Product Selection... this page Specifications... - Approximate Dimensions... - Standards Compliance UL CSA. No. EN/IEC - EN/IEC -- Certifications UL Listed E UR Recognized Component CSA Certified CE Marked Bulletin -FB fuse holders provide a safe and convenient means for installation of class CC, J, and midget fuses. The class CC fuse holder is designed to reject a midget fuse or international x mm fuse. The class J fuse holder will reject all fuses other than a class J fuse. The class CC and J holders are UL Listed and CSA Certified for branch circuit protection. Class CC and J fuses are excellent for wire protection, small motor loads, and group protection of small motor loads. The midget holders are UL Recognized and CSA Certified when supplementary (-/ in. x / in.) fuses are applied. The midget fuse holder is also CE Marked for x mm IEC midget fuses. The -FB fuse holder family is designed for use in many OEM applications, such as power supplies, equipment protection, primary and secondary control transformers, solenoids, lighting and heater loads, and drives. Product Selection One-Pole Two-Pole Three-Pole Description For Class CC Fuse For Class J Fuse For Midget Fuse A A A A Cat. No. Cat. No. Cat. No. Cat. No. -Pole Fuse Block -FBC -FBJ -FBJ -FBM -Pole Fuse Block with Indication,...V -FBC-L -FBJ-L -FBJ-L -FBM-L -Pole Fuse Block with Indication, V -FBC-D -FBM-D Pieces per Carton -Pole Fuse Block -FBC -FBJ -FBJ -FBM -Pole Fuse Block with Indication -FBC-L -FBJ-L -FBJ-L -FBM-L Pieces per Carton -Pole Fuse Block -FBC -FBJ -FBJ -FBM -Pole Fuse Block with Indication -FBC-L -FBJ-L -FBJ-L -FBM-L Pieces per Carton All major fuse brands and current ranges have been evaluated for this fuse holder. Due to the heat they generate, the following fuses must be derated: Ferraz Shamut ATQR. I =. A max. Ferraz Shamut ATQR. I =. A max. Publication A-CAA-EN-P -

40 Bulletin -FB Fuse Holders Accessories/Specifications/Approximate Dimensions Accessories Specifications Product Type (n = number of poles) CC M J J -FBnC "B" -FBC-D "B" -FBnC-L "B" -FBnM "B" -FBM-D "B" -FBnM-L "B" -FBnJ "B" -FBnJ-L "B" For Fuse Type: Class CC Midget /" x -/" Class J ( x mm) Approvals UL, CSA, CE UR, CSA, CE UL, CSA, CE Maximum Voltage Maximum Current Maximum Current Withstand (UL/CSA) Operating Temperature Range Conductor Material Conductor Strip Length Conductor Range Wire per Terminal: Conductor Range Wires per Terminal: Terminal Tightening Torque Description Pkg. Quantity Cat. No. Fuseholder Identification Slide-in Markers -MCX The following are blank cards. Squares slip into molded slot. -MCX Refer to terminal block marking systems on page -. Both wires must be same size V A ka sym. in. ( mm) #... AWG (... mm) #... AWG (... mm) #... AWG: lb in #... AWG: lb in... mm:. N m V V( IEC) A A (IEC) Fuse dependant ka max UL F C Copper, stranded V -FBnJ "B" -FBnJ-L "B" A A #... AWG (... mm) #... AWG (... mm) Approximate Dimensions Dimensions are in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. ka sym. in. ( mm) lb in ( N m) #... AWG (... mm) #... AWG (... mm) Height Depth Width For Class CC Fuse For Class J Fuse For Midget Fuse Dimension A A A A Height. in. ( mm). in. ( mm). in. ( mm). in. ( mm) Depth. in. ( mm). in. ( mm). in. ( mm). in. ( mm) One-Pole. in. ( mm). in. ( mm). in. ( mm). in. ( mm) Width Two-Pole. in. ( mm). in. ( mm). in. ( mm). in. ( mm) Three-Pole. in. ( mm). in. ( mm). in. ( mm). in. ( mm) - Publication A-CAA-EN-P

41 Bulletin F Fuse Holders Product Overview/Selection/Wiring Diagrams Bulletin F Fuse Holders Available for UL Class CC or Midget Fuses and IEC x mm fuses, with or without blown fuse indication Lockable in the open position Compatible with Bulletin M accessories Compact busbar and connectors for Bulletin -C and -K contactors N.O./ N.C. Auxiliary Contact late make N.O., early break N.C. Provides capability for dropping out contactor before breaking current on fuses Late make N.O. contact provides positive indication that power circuit is open Table of Contents Product Selection... this page Approximate Dimensions... - Standards Compliance UL CSA., No. IEC/EN - Product Selection Description Fuse Holder, UL Class CC A max. Fuse Holder with Blown Fuse Indication, UL Class CC A max. Fuse Withstand, Max. [ka] Voltage Rating, Max.[V] Approvals IEC CE Mark UL CSA Yes Yes Cat. No. F-DC-C Yes Yes F-DC-CL Fuse Holder, UL Midget A max. Yes Yes F-DF-C Fuse Holder, IEC x mm A max. Yes Yes Fuse Holder with Blown Fuse Indication, UL Midget A max. Yes Yes F-DF-CL Fuse Holder with Blown Fuse Indication, IEC x mm A max. Auxiliary Contact for Fuse Holder ( N.O. Late Yes Yes Yes Yes F-C-AFA Make + N.C. Early Break) For additional accessories, refer to Bulletin -C/-K contactors and Bulletin M circuit breakers. Wiring Diagrams UL/CSA (ANSI) Motor Stop Start N.O. late make/early break (F-C-AFA) Publication A-CAA-EN-P -

42 Bulletin F Fuse Holders Approximate Dimensions IEC F K A A Approximate Dimensions Dimensions are in inches (mm). Dimensions are not to be used for manufacturing purposes.. (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). () - Publication A-CAA-EN-P

43 Bulletin -GH, -GS High Density Supplementary Protectors Product Overview Bulletin -GH and -GS Supplementary Protectors (Miniature s) High density design allows one-pole breakers per foot Wide range of currents for precise circuit requirements International approvals meet UL, CSA, and EN/IEC standards for worldwide acceptance CE Marked AC and DC voltage ratings in one convenient device A positively trip free mechanism (breaker operation cannot be defeated by holding the handle in the ON position) Superior shock and vibration resistance capabilities helps prevent nuisance tripping Universal mounting foot for a variety of mounting channels, including Cat. No. -N and various mm DIN (e.g., Cat. No. -DR) Table of Contents Product Selection... - Specifications... - Approximate Dimensions... - Standards Compliance UL CSA C. No EN/IEC Certifications UL Recognized Component CSA Recognized Component CE Marked Bulletin high density miniature circuit breakers are thermal magnetic type supplementary overcurrent protective devices. Bulletin - GH miniature circuit breakers are available in one-pole units. Bulletin -GS are available in one-, two-, and three-pole. These breakers are often used when panel space (width) is a premium. These products include a high density design. Up to one-pole breakers can be mounted per foot. The Bulletin -GS breaker can be ordered with auxiliary contacts that do not add any additional space. Wire termination is achieved by a clamping style, self-lifting box lug. One-Pole Style Bulletin -GH This single-pole, high-density miniature circuit breaker incorporates a thermal portion and a magnetic trip function for the combined advantages of two sensing systems. The Bulletin -GH breaker style uses a push-to-set mechanism for circuit actuation and comes with a manual trip button for manually opening the circuit. Voltage range is V AC, and this breaker has a V DC rating. One-, Two-, and Three-Pole Style Bulletin -GS These high-density miniature circuit breakers incorporate a thermal portion and a magnetic trip function for the combined advantages of two sensing systems. The Bulletin -GS style of breakers uses a toggle style handle mechanism for circuit actuation. Voltage range is V AC for the one-pole and Y/V AC for the multiple pole. These breakers have a V DC rating. Product Selection -GH Trip current is % of rated current. Protector will hold % of rated current indefinitely. Will trip within one hour at % of rated current.... A Applications The high-density miniature circuit breaker appliations include, but not limited to, the protection of test equipment, control instrumentation, solenoids, and power supplies. The wide range of current values and the use of a thermal magnetic trip system allows for a variety of applications where a very accurate and compact breaker is required. UL, CSA C. # In North America, miniature circuit breakers are recognized as supplementary protectors and are intended for use as overcurrent protection within an appliance or other electrical equipment where branch circuit protection is already provided or not required. Internationally, these products are rated to IEC standards as circuit breakers for equipment (CBE). -GS... A Seconds Tripping Time at F Percent Rated Current Publication A-CAA-EN-P -

44 Bulletin -GH, -GS High Density Supplementary Protectors Product Selection Using selection table on this page select Bulletin -GH/GS that allows full load current nearest without exceeding application current. Also, check that inrush current is less than trip range of In. -GH/GS To select a miniature circuit breaker, use the following procedure:. Determine the inrush correction factor from the following table. Inrush Ratio Correction Table Inrush Ratio : to : : : : : Factor..... Note: For resistive loads use inrush correction factor of... Determine the temperature correction factor from the following table. Ambient Temperature Correction Table Ambient Temperature F (. C) F (. C) F (. C) F ( C) F (. C) F (. C) Factor Determine the sealed current of the load being protected. F (. C). Multiply the sealed current by the two correction factors and select the closest higher ampere rating. Example For a solenoid with sealed current of. A, an inrush ratio of :, and an ambient temperature of + F (. C), (. x. x. =.), select the. A miniature circuit breaker. Tripping time of the miniature circuit breaker is determined from the table below. Divide the miniature circuit breaker value by the temperature correction factor from the Ambient Temperature Correction Table above to determine the actual rated current referenced in the table below. Percent Rated Current Tripping Times (Seconds) Tripping Times in Seconds at F (. C) % % % % % % % No Trip.... Note: When several breakers are rail mounted adjacent to each other, the no-trip current will be % of rated current at F (. C). -GH -GS -Pole -Pole -Pole -Pole Amperage [A] Cat. No. Cat. No. Cat. No. Cat. No.. -GH -GSG -GSG -GSG. -GH -GSG -GSG -GSG. -GH -GSG -GSG -GSG. -GH -GSG -GSG -GSG. -GH -GSG -GSG -GSG. -GH -GSG -GSG -GSG. -GH -GSG -GSG -GSG. -GH -GSG -GSG -GSG. -GH -GSG -GSG -GSG. -GH -GSG -GSG -GSG. -GH -GSG -GSG -GSG. -GSG -GSG -GSG. -GH -GSG -GSG -GSG. -GSG -GSG -GSG. -GH -GSG -GSG -GSG. -GSG -GSG -GSG. -GH -GSG -GSG -GSG. -GSG -GSG -GSG. -GSG -GSG -GSG. -GSG -GSG -GSG Adding Auxiliary Contact Add suffix H for N.O. aux. One aux. may be installed in all devices. Pieces Per Carton % Greater Max.. - Publication A-CAA-EN-P

45 Bulletin -GH, -GS High Density Supplementary Protectors Specifications/Approximate Dimensions Specifications UL/CSA EN/IEC (CBE) Maximum Voltage Ratings -GH -GS -Pole -Pole -Pole -Pole A (Not to exceed x rated A) V AC / Hz V DC. A ka C ( ka C for V DC -pole) A ka C. A A A A Y/V AC / Hz V DC + F ( + C) non-condensing rated current Temperature Range Operating Life Housing Material Glass-filled Polyamide. Shock G, ms duration Vibration G ( Hz) Dielectric Strength V AC V AC Insulation Resistance M V DC Terminal Type Tubular Screw with self-lifting box lug Wire Size # AWG Recommended Wire Strip Length. in. (. mm) Main Term. in. ( mm) Aux Term. in. (. mm) Terminal Torque.. N m ( lb in). N m ( lb in) Auxiliary Contact rating (N.O. or N.C.). A AC or DC (Resistive Load) Approximate Dimensions Dimensions are in inches (millimeters). Dimensions are not intended for manufacturing purposes. H D W -GH -GS -Pole -Pole -Pole -Pole Height. in. ( mm). in. ( mm) Depth. in. (. mm). in. (. mm) Width. in. (. mm). in. (. mm). in. ( mm). in. (. mm) Publication A-CAA-EN-P -

46 Bulletin -SP Supplementary Protector/Miniature Product Overview Bulletin -SP Supplementary Protector/Miniature Energy limiting design protects downstream components better than conventional breakers during short circuits Field-mountable options for selective applications True IPX finger-safe design (front) International approvals CE Marked, and meets UL, CSA, and IEC (VDE, GL) standards for worldwide acceptance Ratings to Y/V /V AC A interrupt rating AC and DC voltage ratings in one convenient device A positively trip-free mechanism (breaker operation cannot be defeated by holding the handle in the ON position) trip curves: B, C, and D Time delay (D characteristic) for high inrush currents during inductive start-ups such as transformers and power supplies Superior shock and vibration resistance capabilities helps to prevent nuisance tripping Table of Contents Product Selection... - Specifications... - Approximate Dimensions... - Bulletin -SP series C devices are energy limiting, thermal magnetic type overcurrent protectors meeting UL /CSA C. No., IEC/EN. These devices are designed for the protection of a wide variety of products including: Solenoids Transformers Test equipment Automotive systems Controller I/O points Power supplies Relay and contractor coils Medical equipment Computers Control instrumentation The Bulletin -SP supplementary protectors/miniature circuit breakers are available in one-, one-pole plus neutral, two-, three-, and three-pole plus neutral units. One- and two-pole AC units also have limited DC ratings. Two- and three pole units are connected at the handle for simultaneous operation. Screw termination is standard on all Bulletin -SP units. Both line and load side terminals accept #... AWG (... mm) copper wire. Standards Compliance UL CSA C. No. IEC/EN, - UL File Number E CCC GB Certifications UL Recognized CSA Certified CE Marked Germanischer Lloyd (Marine) CCC Tripping Characteristic acc. to EN. ➀ Conventional non-tripping current =. Nt > h nt ➁ Conventional tripping current =.I t N :t < h Ordering Information To order the proper device, you need to know the: ➂. I N :t = - s (I< A) :t = - s (I< A) ➃ Type B: I N :t >. s ➄ I N :t <.s Maximum rated current of equipment to be protected Sytem phase of -, -, or Maximum startup (inrush) current Accessories that are required t [sec] ➅ Type C: I :t = >. s N ➆ I :t = <. s N ➈ Type D: I :t = >. s N I :t = <. s N Use the product selection tables on the following pages to determine the catalog number.. Select a -, -, or -pole device.. If needed, select the Switched Neutral Module. The Switched Neutral Module is mounted on the right side of the breaker. This module must be mounted at the factory. It cannot be installed in the field.. If applicable, consider the derating factors listed in the Determining Ratings section of Publication -TD*. Order accessory contacts or modules as separate items. Accessory modules are always mounted on the left side of the supplemental protector/miniature circuit breaker. A maximum of two accessory modules can be mounted on a single device. Refer to the Accessories table on page - for possible combinations. Multiple of Rated Current (x ln) Tripping Characteristics Bul -SP at C - Publication A-CAA-EN-P

47 Bulletin -SP Supplementary Protector/Miniature Product Selection Product Selection Tripping Characteristics I n I n I n Number of Poles Continuous Current Rating (I n ) [A] Cat. No. Cat. No. Cat. No. -Pole IEC /V AC UL/CSA V AC V DC Trip Curve B Resistive or Slightly Inductive Trip Curve C Inductive Trip Curve D Highly Inductive. -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD Note: Bulletin -SP - and -pole circuit breakers are also available with neutral. Add a suffix of -N to the cat. no. IEC only, does not have CCC, UR, or CSA certifications Publication A-CAA-EN-P -

48 Bulletin -SP Supplementary Protector/Miniature Product Selection Trip Curve B Resistive or Slightly Inductive Trip Curve C Inductive Trip Curve D Highly Inductive Tripping Characteristics I n I n I n Number of Poles Continuous Current Rating (I n ) [A] Cat. No. Cat. No. Cat. No. -Pole. -SPC -SPD -SPB -SPC -SPD IEC V AC UL/CSA Y/V AC V DC -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -Pole. -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD IEC V AC UL/CSA Y/V AC Note: -SP - and -pole circuit breakers are also available with neutral. Add a suffix of -N to the cat. no. IEC only, does not have CCC, UR, or CSA certifications -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD -SPB -SPC -SPD - Publication A-CAA-EN-P

49 Bulletin -SP Supplementary Protector/Miniature Accessories Accessories The following bus bars (commoning links have CE certification only) Auxiliary Contacts Undervoltage release module Use the undervoltage release module to trip the adjacent breaker poles when the applied voltage is less than the nominal voltage. Undervoltage trip is often used when loss of power and eventual restoration of power creates an unsafe or unknown set of condition. Shunt trip module Use the shunt trip module to trip the adjacent breaker poles from a remote location. The module is actuated by applying a voltage (pickup voltage) to the trip terminals. Shunt trip modules are often used in emergency shutdown circuits where multiple power circuits must be switched off from a single location. Description Auxiliary contact module Switches when protective device is operated manually or tripped electrically N.O. N.C. Form C Contact Dual auxiliary contact module Switches when protective device is operated manually or tripped electrically N.O. N.C. Form C Contact Auxiliary/signal alarm contact module Auxiliary Contact switches when protective device is operated manually or tripped electrically N.O. N.C. Form C Contact Signal Contact switches when protective device is tripped electrically N.O. N.C. Form C Contact V AC V AC V AC ( V DC) V AC ( V DC) Cat. No. -ASPH -ASPHH -ASPHS -ASPU -ASPU -ASPA -ASPA Mounting Rail Pkg Qty: -DR End Anchor -EAH Lockout Attachment Pkg Qty: -ASPLOA Publication A-CAA-EN-P -

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

1489-M Circuit Breakers

1489-M Circuit Breakers Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Terminal design helps prevent wiring misses Scratch- and solventresistant printing Suitable

More information

Series L9 UL-489 Miniature Circuit Breakers

Series L9 UL-489 Miniature Circuit Breakers Series UL-489 iniature Breakers Industrial Breakers for Branch up to 40 Amps Sprecher+Schuh includes a line of circuit breakers approved for branch circuit applications in the United States and Canada

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

1492-CB 1492-GH 1492-GS

1492-CB 1492-GH 1492-GS 1 The Allen-Bradley Line of Devices Allen-Bradley offers 3 different lines of Circuit Breakers (Supplementary Protectors) and a line of branch circuit rated Fuse Holders. Allen-Bradley Thermal Magnetic

More information

Series L9 UL489 Miniature Circuit Breakers

Series L9 UL489 Miniature Circuit Breakers Series L9 UL489 iniature Circuit Breakers Industrial Circuit Breakers for Branch Circuit Protection up to 63 Amps L9 Series B Circuit Breakers Series B L9 UL489 circuit breakers offer new features, expanded

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

Circuit Protection. Circiut Protection

Circuit Protection. Circiut Protection Circuit Protection Series L8 UL1077 Supplementary Protectors...2 Selection Guide - Trip Curve "B"...4 Selection Guide - Trip Curve "C"...5 Selection Guide - Trip Curve "D"...6 Accessories...7 Technical

More information

S200 UL 489 Series. Miniature Circuit Breakers. Description. Features

S200 UL 489 Series. Miniature Circuit Breakers. Description. Features S200 UL 489 Series Miniature S200 UL 489 Series Miniature Circuit Breakers Description The S200 Series miniature circuit breaker offers a compact solution for protection requirements. The S200U AND S200UP

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics Miniature circuit breakers General information General information Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are recognized for

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

KT4 Manual Motor Starter

KT4 Manual Motor Starter KT4 Manual Motor Starter Ideal for use as a manual starter The KT4 is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE Bulletin R Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects 0 A A Sizes Fused Switch Versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC - UL Class J - UL Class CC - NFC Non-Fused

More information

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects Bulletin R IEC Fused and Non-Fused Disconnects, & A Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects A A Sizes Fused switch versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices UL 077 Series Supplementary protective devices The UL 077 Series miniature supplementary protector offers a compact solution for protection requirements. The devices are DIN rail mounted. The is available

More information

Miniature circuit breaker Application guide

Miniature circuit breaker Application guide Miniature circuit breaker Application guide Miniature Miniature circuit circuit breakers breakers Application S200 guide Introduction The circuit breaker plays an important role in providing over-current

More information

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description UL 489 Series UL 489 Series Description The Series miniature circuit breaker offers a compact solution for protection requirements. The U AND UP devices are UL 489 tested limiting and DIN rail mounted.

More information

Ideal for use as a manual starter

Ideal for use as a manual starter Manual Motor Starter Ideal for use as a manual starter The is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one compact

More information

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4. Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Miniature Circuit-Breakers (MCBs)

Miniature Circuit-Breakers (MCBs) Product Overview Miniature Circuit-Breakers (MCBs) Design Tripping characteristics Rated current I n Rated breaking capacity Power supply company product range 5SP3 E 16 - A Standard product range 5SQ2

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00, Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,

More information

Self-protected Combination Starters System PKZ 2-SP

Self-protected Combination Starters System PKZ 2-SP Self-protected Combination Starters System PKZ 2-SP 03/035 PKZ 2/ZM/S-SP motor starters: a higher level of protection and versatility : The PKZ 2/ZM/S-SP is a self-protected starter, the first motor controller

More information

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Phone: Fax: Web:  - Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

Bulletin 190-M Compact Starters. Selection Guide

Bulletin 190-M Compact Starters. Selection Guide Bulletin 190-M Selection Guide Bulletin 190-M Selection Guide 3 Bulletin 190-M Compact Design to 45mm Wide Common Adapter for Panel or DIN Rail Mounting Pre-Wired Assembly All Control Terminations Located

More information

FMotor Circuit Controllers

FMotor Circuit Controllers Technical Information Motor Circuit Controller IEC Performance Data Catalog Number KTA7-25S...32S 0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 16A 20A 25A 29A 32A Rated Operational Current, I e [A]

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Product Line Overview. The Most Logically Designed Contact Assembly

Product Line Overview. The Most Logically Designed Contact Assembly Circuit Breakers & Supplementary Protectors 15 00 Amperes for UL, CSA & IEC Applications Product Line Overview -3 General Information Cutler-Hammer Series G Molded Case Circuit Breakers provide increased

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

XT IEC Power Control Manual Motor Protectors

XT IEC Power Control Manual Motor Protectors May 07 Product Selection Table 7. Rotary with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted

More information

AP/UP, AP/MIL Series Magnetic Circuit Protectors

AP/UP, AP/MIL Series Magnetic Circuit Protectors AP/UP, AP/MIL AP/UP, AP/MIL Series Magnetic Circuit Protectors Introduction 68 Single Pole 69 Multi-Pole 70 Configurations 72 Operating Characteristics 73 Delay Curves 74 Specifications 75 Decision Tables

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

Bulletin 140M Motor Protectors

Bulletin 140M Motor Protectors 0Circuit Breaker Bulletin 140M Bulletin 140M Cat. No. 140M-C2E Cat. No. 140M-F8E Current Range 0.1...45 A With 140-CMN up to 90 A Type 2 Coordination with Bulletin 100-C Contactors UL Listed Self-protected

More information

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x. Types MS116, MS132, MS5x, MS9x are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/OFF control, and protection against short circuit,

More information

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction Introduction Introduction Schneider Electric offers a complete line of products for the manual control and protection of motors. This catalog covers those devices designed to meet IEC standards for protection

More information

US CATALOG. Miniature circuit breakers

US CATALOG. Miniature circuit breakers US CATALOG Miniature circuit breakers Table of contents 004 024 S(U)200 series miniature circuit breakers UL 489 series 025 048 S200 series miniature circuit breakers UL 1077 series 049 056 Application

More information

Miniature Circuit Breaker UL / CSA Range

Miniature Circuit Breaker UL / CSA Range PRODUCT CATALOG CANADA Miniature Circuit Breaker UL / CSA Range UL489 / CSA C22.2 No.5 devices UL1077 / CSA C22.2 No. 235 devices Electronic Protection Devices Technical data Miniature Circuit Breakers

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

Miniature Circuit Breakers

Miniature Circuit Breakers S00 Series Miniature S00 Series Miniature Circuit Breakers Description The S00 Series miniature circuit breaker offers a compact solution for protection requirements. The S00 devices are UL tested limiting

More information

DX³ 4-pole RCBO 6000 A/10 ka

DX³ 4-pole RCBO 6000 A/10 ka 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

ECET Distribution System Protection. Overcurrent Protection

ECET Distribution System Protection. Overcurrent Protection ECET 4520 Industrial Distribution Systems, Illumination, and the NEC Distribution System Protection Overcurrent Protection One of the most important aspects of distribution system design is system protection.

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for

More information

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz Catalog Number Explanation Open Controllers a Bulletin Number Solid-State Controller B H H B B B B B B B B B B B B B Solid-State Controller and Isolation Contactor (enclosed only) b Controller Ratings

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

US CATALOG. Miniature Circuit Breakers

US CATALOG. Miniature Circuit Breakers US CATALOG Miniature Circuit Breakers Miniature circuit breakers Table of contents S(U)200 series miniature circuit breakers UL 489 series Description and features 2 SU200M-C 3 SU200M-K 4 SU200M-Z 5 SU200MR-K

More information

Motor Protection Circuit Breaker and Motor Circuit Protector Specifications

Motor Protection Circuit Breaker and Motor Circuit Protector Specifications Technical Data Motor Protection Circuit Breaker and Motor Circuit Protector Specifications Bulletin Number 140M Topic Page Bulletin 140M Motor Protection Circuit Breakers 3 Overview 3 Catalog Number Explanation

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

Motor Controllers + Circuit Breakers

Motor Controllers + Circuit Breakers Series General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information -...20 Dimensions -...33 Technical Information - KTA3-100...39 Dimensions

More information

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931 Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC

More information

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59. Single Pole Circuit Protectors 55 Multi-Pole Circuit Protectors 56 Configurations 58 Operating Characteristics 59 Delay Curves 60 Specifications 61 Decision Tables 62 SINGLE POLE CIRCUIT PROTECTORS The

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

PD-Series Ground Fault Circuit Protection

PD-Series Ground Fault Circuit Protection PD-Series Ground Fault Circuit Protection SmartGuard is an equipment ground fault protection device that functions as a standard high-quality Carling hydraulic/ magnetic circuit breaker, offering customized

More information

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2 Series KT7 General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information - KT7...20 Dimensions - KT7...32 Technical Information - KTA3-100...37

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

System pro M compact Miniature Circuit Br eakers Description Features

System pro M compact Miniature Circuit Br eakers Description Features System pro M compact Miniature Circuit reakers S0 Series Description Increasing energy requirements result in larger short-circuit currents which place heavy demands on protective switchgear regarding

More information

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489 MINIATURE CIRCUIT BREAKERS SU200M Datasheet Branch protection acc. to CSA C22.2 No.5 / UL 489 The miniature circuit breaker SU200 M is ABB s solution for UL 489 branch circuit protection up to 480 Y/277

More information

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Characteristics of LV circuit breakers Releases, tripping curves, and limitation Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break

More information

3.2. Current Limiting Fuses. Contents

3.2. Current Limiting Fuses. Contents .2 Contents Description Current Limiting Applications................. Voltage Rating.......................... Interrupting Rating....................... Continuous Current Rating................ Fuse

More information

209 Series. Magnetic Circuit Protectors

209 Series. Magnetic Circuit Protectors 29 Series Magnetic Circuit Protectors Introduction 249 Power Selector System Multi-Pole Configurations Operating Characteristics Delay Curves Specifications Decision Tables 73 75 77 79 8 82 85 87 29/29/229/249/279

More information

DX³ RCCBs - ID 4P up to 100 A

DX³ RCCBs - ID 4P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Bulletin 194R TABLE OF CONTENTS Bulletin 194R IEC Fused and Non-Fused Disconnects

Bulletin 194R TABLE OF CONTENTS Bulletin 194R IEC Fused and Non-Fused Disconnects 4 Bulletin 194R TABLE OF CONTENTS Bulletin 194R 20 A 400 A Sizes Open or Enclosed Switches d Switch Versions: BS88 DIN CSA HRCII-C CSA HRCI-J UL Class J UL Class CC Non-d Switches Operating Handle Ingress

More information

UL Enclosed Disconnect Switches (Fused and Non-Fused)

UL Enclosed Disconnect Switches (Fused and Non-Fused) Product Selection UL Enclosed Disconnect Switches (Fused and Non-Fused) Catalog Number Explanation 194R-K Non-Metallic Enclosure UL Type 3/4/4X, IP66 194R-F Painted Steel Enclosure UL Type 3/4/12, IP66

More information

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications Student Resource Building University of California Santa Barbara Clement Fung Lighting Electrical Option APPENDIX E Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control . Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Relays.................... C440/XT Electronic

More information

and other modular devices for low voltage installation

and other modular devices for low voltage installation Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories

More information

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J Protection Equipment Siemens AG 2015 Click on the Article No. in the catalog PDF to access it in the Industry Mall and get all related information. Article-No. 3RA1943-2C 3RA1943-2B 3RA1953-2B 3RA1953-2N

More information

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC. Page -2 Page -2 AC FUSE HOLDERS Version without indicator: 1P, 1P+N, 2P, 3P, 3P+N Version with indicator: 1P For fuses x38, 14x51 and 22x58mm IEC class gg or am. IEC rated current: 32A, 50A, 0A IEC rated

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, NEMA /) Controllers For use with Line-Connected Motors Rated Voltage [V AC] / Motor Current [A]...... Max. kw, Hz Max. Hp, Hz Control

More information

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489 Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection

More information

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

Star Series Motor protection & control

Star Series Motor protection & control Contact us ABB Inc. Low Voltage Control Products 16250 W. Glendale Drive New Berlin, WI 53151 Phone: 888-385-1221 Fax: 800-726-41 USA Technical support & Customer Service: 888-385-1221, Option 4 7:30AM

More information

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting. DATASHEET - ZB12-2,4 Delivery program Overload relay, 1.6-2.4 A, 1N/O+1N/C Part no. ZB12-2,4 Catalog No. 278437 Eaton Catalog No. XTOB2P4BC1 EL-Nummer 0004131832 (Norway) Product range Overload relay ZB

More information

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised: File E47705 Vol. 7 Sec. 9 Page 1 Issued: 1997-08-29 and Report Revised: 2005-06-30 DESCRIPTION PRODUCT COVERED: USL, CNL - Type Nos. 3RV1021, 3RV1121, 3RV1321 or 3RV1421, followed by combination of 0,

More information

Bulletin 1492-J, -W 1492-L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks

Bulletin 1492-J, -W 1492-L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks Bulleting IEC Terminal Blocks Overview and Regulatory Information Bulletin -J, -W -L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks Technology Screw terminations are a time-proven method

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

CENTERLINE 2100 Motor Control Centers

CENTERLINE 2100 Motor Control Centers TECHNICAL DATA CENTERLINE 2 Motor Control Centers Instantaneous Trip Motor Circuit Protectors (MCP) in Combination NEMA Starter, Soft Starter (SMC) and Variable Frequency AC Drive Units 1A Frame Instantaneous

More information

(1,5 modules per pole)

(1,5 modules per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 36kA, 80A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information