Magic Access Dual Operator. ML20906 LWA 24AD CMK M92 MK VKC2 630 Cylinders V-7 CMK MK VKC2 FB31T FB32 FB51T FB52. US28 Coordinator COR42

Size: px
Start display at page:

Download "Magic Access Dual Operator. ML20906 LWA 24AD CMK M92 MK VKC2 630 Cylinders V-7 CMK MK VKC2 FB31T FB32 FB51T FB52. US28 Coordinator COR42"

Transcription

1 U of L Destination Project - RFP - M Lethbridge, Alberta DOOR HARDWARE SECTION Appendix B Hardware Details Mfg Short Description Product Number Finish ADDS Door Contact 1078 GREY CST Auto Operator Magic Access Dual Operator ANCLR Touchless Activation Device MS08 X White w/text CAIS Lockset ML2057 LWA CMK M92 MK VKC2 CCR Lockset ML2057 LWA CMK MK VKC2 630 Passage Set ML2010 LWA 630 Privacy Set ML2060 LWA M19V 630 Electrified Lockset ML20906 LWA 24AD CMK M92 MK VKC2 630 Cylinders A02-6 CMK MK VKC2 630 Rim Cylinder V-7 CMK MK VKC2 630 CGL Overhead Stop 104S US32D Overhead Stop 105S US32D Overhead Stop 106S US32D CIV Top Auto Flush Bolt FB31T US32D Top Auto Flush Bolt FB32 US32D Top Auto Flush Bolt FB51T US32D Top Auto Flush Bolt FB52 US32D Coordinator COR42 US28 Coordinator COR52 US28 Filler Bar FL20 US28 CLC Closer 4040 SE STD 24VAC/DC 689 CMC Hinges TA X D Hinges TA X 101 NRP 26D Hinges TA X 101 QC8 26D Hinges TA X D Hinges TA X 114 NRP 26D Hinges TA X 114 QC8 26D Hinges TA X 114 NRP QC8 26D Hinges TA X D Hinges TA X 114 NRP 26D Hinges TA X 114 QC8 26D Wiring Harness Wiring Harness Wiring Harness Wiring Harness CORS CSM STMS CSN CVO Wi-Fi Lockset Wi-Fi Lockset Flushbolt Flushbolt Door Pull Flushbolt Push Pull Set Pulls Magnalock Concrete/Wood Brkt Dress Cover Power Supply Exit Device Exit Device Exit Device Exit Device Exit Device QC-C006 QC-C1500P QC-C306 QC-C400 IN120 ML20133 LSA B IPS 630 IN120 ML20134 LSA B CMK IPS MK VKC2 630 F F65 UL # 2 MTG. F65 UL X #5 MTG X #5 MTG M62BD CWB-62CL DC-62CL BPS EO 98EO 48" CX 98L x E996L-R&V 03-LEVER 48" CON CX RX (trim) 98L x 996L-BE-R&V 03-LEVER 48" CON CX RX (trim) 98L x 996L-BE-R&V 03-LEVER CON 26D 26D 32D 26D C32D 32D US32D US32D US32D US32D US32D July 11, 2017 Page 2 of 4 Click to go to page Page 5 Page 7 Page 10 Page 13 Page 29 Page 33 Page 37 Page 38 Page 39 Page 47 Page 58 Page 61 Page 62 Page 73 Page 74 Page 80 Page 83 Page 85 Page 86 Page 87 Page 88 PAGE 002

2 U of L Destination Project - RFP - M DOOR HARDWARE Lethbridge, Alberta SECTION Exit Device Exit Device Exit Device Fire Exit Device Fire Exit Device Fire Exit Device Fire Exit Device Fire Exit Device Fire Exit Device Electric Strikes Power Supply Power Supply Power Transfer Wire Harness Wire Harness QEL RX 3547A-L x 360-L 03-LEVER 10' DOOR EXTENSION 48" 35A-EO 33A-GBK-R 48" RX 35A-L x 360-L 03-LEVER 48" 9827L-F x 996L-BE-R&V 03-LEVER 98EO-F 98EO-F 48" 98-ALK-RX CON 98L-F x 996L-BE-R&V 03-LEVER CX RX (trim) 9827L-F x 996L-BE-R&V US32D US32D US32D US32D US32D 03-LEVER 36" EXTENSION CON LBR QEL 98L-F x 996L-NL-R&V 03-LEVER CON US32D VDC CON FSE US32D PS FA PS RS-FA EPT 10 CON CON-12 CON-192P SP28 Page 102 Page 110 Page 111 Page 113 July 11, 2017 Page 3 of 4 PAGE 003

3 GE Magnetic Contacts Product Information Steel Door Contact 3 /4 and 1 contacts 1078/1076 Series Overview The GE Interlogix 1078 Series Steel Door contacts are designed specifically for use in the steel doors commonly found in commercial building applications. The unique housing design features a rugged unibody construction with flexible ribbed sides for quick, secure installation without gluing. The magnet housing isolates the magnet from the surrounding steel for maximum gap distances, both make and break. Over seven models including: Wide Gap, SPDT, DPDT, and Biased for High Security applications make the 1078 Series the most widely used and comprehensive line available. Architectural and Engineering Specifications Designed for use in Steel Doors On available models a terminal connection (T) makes installation easier. Simply strip the wire, insert it into the terminal block and tighten. The terminal accepts any wire size from 14 to 22 gauge, and has a unique one piece design for added strength. An optional Rare Earth Magnet is available. It is designed for use in metal entry/exit doors with a channel in the top of the door. The magnet eliminates the need to cut a mounting hole in the door channel. The flexible magnet housing can be compressed to accommodate a variety of channel widths for quick, easy installation. Adhesive is recommended. The contact contains a hermetically sealed magnetic reed switch. The reed shall be potted in the contact housing with a polyurethane based compound. Contact and magnet housing shall snap-lock into a 3/4" or 1" dia. hole. Housings shall be molded of flame retardant ABS plastic. Color of housings shall be off-white, grey or mahogany brown. The magnet shall be made of Alnico V. Rare Earth Magnet shall be made of neodymium iron boron. Snap-lock insulation bushing for tight fit and maximum gap in steel. Both contact and magnet plastic housings are constructed of one piece of thick-walled ABS plastic for maximum strength and durability. Standard Features Optional 1840 Rare Earth Magnet Fly leads and terminal options available Designed specifically for use in steel doors Special ribbed sides allow for easy installation Rugged unibody construction for maximum durability and reliability Terminal models available for easier installation Regular, Wide Gap, SPDT, DPDT, and High Security models available Rare Earth Magnet designed for steel door with top channel available Model numbers 1076, 1076W, 1076C, 1076CW, 1076D, 1078, 1078W, 1078C, 1078CT, (R)1078, 1078CTW Phone: Fax: Web: info@clrwtr.compage 005

4 Steel Door Contact 3 /4 and 1 contacts 1078/1076 Series Dimensions Specifications Models: (R)1078, 1078W, 1076, 1076W, 1076D Models: 1078C, 1076C, 1076CW, 1076CH 1.125" 2.86 cm 1.125" 2.86 cm 1.125" 2.86 cm.875" 2.22 cm 1.00" 2.54 cm 1.563" 3.97 cm 1.563" 3.97 cm Magnet Part No (included).375".962 cm.750" 1.91 cm Magnet Part No. 1921C (included) Form A: (R)1078, 1078W, 1078C, 1078CT, 1078CTW Voltage 100V AC/DC max. Current 0.5 A max. Power 7.5 W max. Form C: 1076, 1076W, 1076D, 1076C(D), 1076CW, 1076CH Voltage 30V AC/DC max. Current 0.25 A max. Power 3.0 W max. Rare Earth Magnet Models: 1078CT, 1076CTW, 1.625" 4.13 cm 1.56" 3.96 cm 0.375" 0.64 cm 0.89" 2.26 cm 1.813" 4.60 cm (R) prefix indicates Rare Earth Magnet Ordering Information Model Dia. Loop Type Electrical Config. Hole Required Gap Distance* Contact Magnet Wood* Steel* Rare Earth Color 1 1 Up to 1 / 2 Up to 5 / Up to /4 Up to 3 / 8 Up to 5 / Up to 1 / 2 Up to 5 / Up to 1 3 /4 7 /8 Up to 3 / 8 Up to 5 / W 1076D W 1076C 1076CW 1078C (R) CT 1078CTW 3 /4 3 /4 1 3 /4 3 /4 Open or Closed Open or Closed Open or Closed Closed Closed Open or Closed Open or Closed Closed Closed Closed Closed 0.938" 2.36 cm SPDT SPDT DPDT N/O N/O SPDT SPDT N/O N/O N/O N/O Magnet Part No (included) * Gap distances are nominal make distance ±20%. Gap specifications are for switch to make. Break distance is approximately 1.1 to 1.5 times make. 0.75" 1.91 cm 1 x x x x x x x x x x x x x x x x x x x x x x " 4.13 cm 0.5" 1.27 cm 0.625" 1.59 cm Legs may be cut for Height Adjustment 2 Up to 3 / 4 1 /2 N/A 1 Up to 1 / 2 Up to 5 / 8 7 /8 1/ 2 5 /8 5 /8 3/ 4 N/A Protected by U.S. Patent 5,844,458. M, N, G M, N, G M, N, G M, N, G M, N, G M, N, G M, N M, N, G M, N M, N N GE Interlogix 2002 GE Interlogix. All trademarks are properties of their owners. C-3617-FLG10K-0403 Phone: Fax: Web: info@clrwtr.compage 006

5 Magic-access Tm low energy swing door operator Medium-to-Low Duty Swing Door Operator with Light Manual Opening Force The STANLEY Magic-Access Low Energy Operator is designed to provide a cost effective, custom solution for automating swing doors. This medium-to-low duty swing door operator can automate new or existing swing door panels up to 125 pounds through the use of a push plate, wave sensor, or other knowing act device. The header width is customized to span the full width of the door opening, adding to a finished, aesthetically pleasing look. The end result is a professionally installed automatic door system that is quiet, smooth, and safe. FEATURES AND BENEFITS Powers door panels up to 42 (1067 mm) wide and 125lbs (57 kg) Lighter manual opening force as compared to the force required on a manual swing door Adjustable closing time delay UL listed for service in the U.S and Canada, complies with ANSI/BHMA A and meets the applicable provisions of ANSI Acts as a mechanical closer for manual operation in the event power is shut off Microprocessor-based controller will stop immediately at any point of the doors swing cycle when an obstacle is detected. A DIVISION OF: PAGE 007

6 TO OPEN TO PUSH TO OPEN TO OPEN TO PUSH TO OPEN TO PUSH TO OPEN PUSH TO OPEN TO TO PUSH TO OPEN PUSH TO OPEN Magic-access low energy swing door operator optional features Custom finishes Sequencing module Lock delay module Power close selectable Magic Touch Activation for power open when opened manually past 3 Complete factory engineered door system that includes center pivoted door panels Mounting Options Surface mount Overhead concealed In-swing Out-Swing SPECIFICATIONS Header Size Swing Door Panels Door Panel Weight Drive System Controller Activation Options Breakout Power Required 6 1/8 (152mm) high x 4.0 (102mm) deep Up to 42 (1067mm) Up to 125lbs (57kg) 1/8 HP DC motor, gear drive Electronic control system with built-in reverse-on-obstruction Mats, push plates, touch-less wave sensors, wireless radio controls, or Magic-Touch Activation Breakaway door stop 120 VAC, minimum of 5 amp, 50/60 HZ Code Compliance UL/cUL 325, UL10C, ANSI/BHMA A156.19, IBC, NFPA 101, ANSI PUSH OPEN PUSH TO Activation PUSH OPEN PUSH OPEN PUSH OPEN PUSH TOUCH-LESS wave sensors push plates radio controls & card readers PUSH OPEN PUSH OPEN RAIL elevation views surface mounted Visible "OUT" surface mounted Visible "IN" Concealed PAGE Stanley Access Technologies LLC. SAT /16 StanleyAccess.com/magic-access ACCESS Service 888-DOOR-444

7 PAGE 009

8 MAGIC SWITCH: MS08 ADJUSTABLE RANGE TOUCHLESS ACTUATOR PRIMARY APPLICATIONS 4 to 24 in DESCRIPTION BEA s MS08 utilizes proven microwave motion technology to ensure consistent, dependable touchless activation and can be adjusted to comply with the ANSI knowing act standard. The MS08 detects moving objects such as a hand, cart or wheelchair and is ideal for use in hospitals, pharmacies, clean rooms, food service facilities and other applications requiring a hygienic activation method. FEATURES & BENEFITS Detection zone from 4 to 24 inches (pulse or toggle) Silent activation for hospitals and other noise-sensitive environments Water-resistant foam gasket provides increased reliability when exposed to liquid or cleaning products Low profile, beveled design reduces chance of accidental damage in high traffic areas Available in white, black or cream faceplate; options for single or double gang boxes Multiple faceplate graphic options available Inter-operates with all automatic door control makes and models BEA, Inc. RIDC Park West 100 Enterprise Drive Pittsburgh, PA Customer Service: Technical Support: PAGE 010

9 APPLICATIONS RELATED PRODUCTS SWING DOORS DUAL EGRESS 10MS08U SINGLE & DOUBLE GANG FACEPLATES SINGLE GANG BLACK WITH TEXT DOUBLE GANG BLACK WITH TEXT SLIDING DOORS INDUSTRIAL DOORS TECHNICAL SPECIFICATIONS SINGLE GANG SOLID BLACK DOUBLE GANG SOLID BLACK SINGLE GANG BLACK WITH LOGO Technology Microwave Doppler Radar Radiated Frequency Radiated Power Density GHz 5 mw/cm 2 Detection Mode Motion (bidirectional) Detection Range Output Max. Voltage Max. Current Max. Switching Power 4 to 24 inches (adjustable) Relay with switch-over contact (voltage free) 60 VDC / 125 VAC 1 A (resistive) 30 W (DC) / 60 VA (AC) DOUBLE GANG BLACK WITH LOGO SINGLE GANG WHITE WITH TEXT DOUBLE GANG WHITE WITH TEXT Output Hold Time 0.5 s (in pulsed mode) Supply Frequency 50 to 60 Hz Supply Voltage 12 to 24 VAC ±10% 12 to 24 VDC +30% / -10% Power Consumption Material < 1.5 W ASA, Nylon, PC Cable Type Standard cable up to 16 AWG mm SINGLE GANG SOLID WHITE DOUBLE GANG SOLID WHITE SINGLE GANG CREAM WITH TEXT Temperature Range -4ºF to +131ºF (-20ºC to +55ºC) Norm Conformance EMC: 2004 / 108 / EC; FCC: G9B-MS08; IC: 4680A-MS08 DIMENSIONAL DRAWINGS DOUBLE GANG CREAM WITH TEXT SINGLE GANG SOLID CREAM DOUBLE GANG SOLID CREAM 10RD MHZ RECEIVER MODULE TD900RT 900 MHZ RETROFIT TRANSMITTER CUSTOM PACKAGE MS08U CUSTOM 10MS08U plus choice of any one of the additional faceplates BEA, Inc. All rights reserved. MAGIC SWITCH: MS08 ADJUSTABLE RANGE TOUCHLESS ACTUATOR BEA, Inc. RIDC Park West 100 Enterprise Drive Pittsburgh, PA Customer Service: Technical Support: PAGE 011

10 ML2000 Series Mortise Locksets PAGE 013

11 Overview ML2000 Series Table of Contents ML2000 Series Overview...2 ML2000 Series Features ML2000 Series Functions ML20900 ECL Applications...10 ML20900 ECL Features...12 ML20900 ECL Functions...13 ML20600 NAC Series Electrified Mortise Lock with High Security Monitoring...14 NAC Functions NAC How to Order...17 Trim Designs Muséo Trim...38 Muséo Inspire Roseless Trim...39 Muséo Levers Vineyard Collection Trim Vandal Resistant Trim (VR)...54 Behavioral Health Trim (BHSS)...57 Behavioral Health Lever Trim (BLSS)...58 Push/Pull Trim (HPSK) Anti-Harm Trim (HSS) Options and Accessories How to Order Quick Codes How to Specify Reversing Handing...79 Quality The ML2000 Series is a Grade 1 mortise lock designed to meet the rigors of high-traffic commercial, institutional, industrial and government applications. Constructed of heavy-gauge steel, the lockbody features our patented Quick Reversible latchbolt, and a 1" stainless steel deadbolt. A wide variety of trim designs and functions and a 10-year warranty lend to the ML2000 s versatility and reliability, making it the ideal choice for use in offices, schools, hospitals, hotels and other high-use applications. Security Further discourage intrusion and abuse with the ML2000VR (Vandal Resistant) series mortise lock. This lock features vandal-resistant stainless steel escutcheons with tapered edges and Torx pin tamper resistant screws. When matched with Corbin Russwin patented high-security cylinders, any door can become a formidable barrier to intruders. Aesthetics Complement any application with the full range of trim designs and finishes offered with ML2000 Series. From stainless steel security trims to bright brass Vineyard levers, design continuum can be achieved without forfeiting aesthetics. For additional information regarding designer trim, see the Corbin Russwin Vineyard Collection and Muséo Collection catalogs. Key Advantages Patented Quick Reversible feature enables reversal of hands without disassembling the lock case (Patent # 6,349,982) Security trims provide a vandal-resistant barrier Can be used with new or existing Corbin Russwin key systems. Also accepts cylinders of most other manufacturers. Provides life safety and security in a single door prep, saving the additional cost of a deadlock Through-bolted trim designs for proper alignment and increased security ML PAGE 014 Copyright Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited /17

12 Overview Features ML2000 Series Features Handing Handed; quick reversible. The lockset can be re-handed without disassembling the lock case; see page 79. Door Thickness 1-3/4" (44mm) standard. Optional door thicknesses available; see Quick Codes, page 74. Backset 2-3/4" (70mm). Lockcase Heavy-gauge steel, 5-7/8" (149mm) x 4" (102mm) x 15/16" (24mm). Optional: non-ferrous lockcase for corrosion resistance; see Quick Codes, page 74. Front Heavy-gauge steel, 8" (203mm) x 1-1/4" (32mm) x -3/32" (2mm). Accommodates flat doors and doors beveled 1/8" (3mm) in 2" (51mm). Furnished 1-1/16" (27mm), optional D138, wide for 1-3/8" (35mm) doors. Armored Front Wrought brass, bronze or stainless steel attached by machine screws to lockcase front. ML2000VR utilizes security Torx screws. Latchbolt 2-piece mechanical with anti-friction insert, 5/8" (16mm) x 1" (25mm) x 3/4" (19mm) throw. Auxiliary Latchbolt 9/16" (14mm) effective throw and 3/8" (10mm) effective auxiliary latch deadlocking. Deadbolt One-piece stainless steel, 19/32" (15mm) x 1-1/4" (32mm) x 1" (25mm) throw. Occupancy Indicator Occupancy indicators for use with ML2000 x sectional trim. Design features option for dual indicators on double cylinder functions, confirming door is secured from either side. Emergency override standard for all non-keyed functions. Hub Knob: stainless steel, 9/32" (7mm) x 9/32" (7mm). Lever: steel, 5/16" (8mm). (Including VR ) Spacing C. to c. knob/lever to cylinder: 3-5/8" (92mm). C. to c. knob/lever to thumbturn: 2-7/16" (62mm). Strike Wrought brass, bronze or stainless steel, ANSI straight lip standard, 4-7/8" (124mm) x 1-1/4" (32mm) x 1-1/8" (29mm) lip to center. Optional strikes, lip lengths and ANSI wrought strike box available; see Quick Codes, page 74. Cylinder Brass, 6-pin, L4 keyway, 0-bitted standard. Optional cylinders available; see Quick Codes, page 73. Keys Two nickel silver standard. Keying Features Available Master keying Construction master keying Visual key control Concealed key control Plug only to show (concealed shell) 7-pin cylinder Security cylinder Access 3 cylinder Pyramid cylinder Interchangeable core (IC) Security IC Pyramid IC Access 3 IC Master ring cylinder Blockout cylinder Flex head cylinder Warranty Ten-year limited. Certification/Compliance ANSI/BHMA Certified A Series 1000, Operational and Security Grade 1. Meets A117.1 Accessibility Code. Federal Meets FF-H-106C. UL/cUL-UL10C Positive Pressure All locks listed for A label and lesser class doors, 4' (122cm) x 10' (305cm) single or 8' (244cm) x 10' (305cm) pair (3 hour fire door). Letter F and UL symbol on armored front indicate listing. Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and Corbin Russwin, Inc. makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing firerated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes and ratings. California State Reference Code (Formerly Title 19, California State Fire Marshal Standard) All levers with returns, return to within 1/2" (13mm) of door face. Windstorm/Hurricane Certified (refer to local codes). VR Indicates ML2000VR (Vandal Resistant) availability /17 PAGE 015 ML Copyright Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.

13 Features Overview ML2000 Series Finishes ANSI/BHMA 605 (US3) ANSI/BHMA 606 (US4) ANSI/BHMA 611 (US9) ANSI/BHMA 612 (US10) ANSI/BHMA 613 (US10B) 613E (US10BE) 613L ANSI/BHMA 618 (US14) ANSI/BHMA 619 (US15) ANSI/BHMA 625 (US26) ANSI/BHMA 626 (US26D) Bright Brass Satin Brass Bright Bronze Satin Bronze Oxidized Bronze, oil rubbed Dark Oxidized Satin Bronze - Equivalent Dark Oxidized Satin Bronze, Clear Coated Bright Nickel Plated Satin Nickel Plated Bright Chromium Plated Satin Chromium Plated 626C Satin Chromium Plated with MicroShield ANSI/BHMA 629 (US32) VR Bright Stainless Steel ANSI/BHMA 630 (US32D) VR Satin Stainless Steel 630C Satin Stainless Steel with MicroShield 722 Black Oxidized Bronze, oil rubbed Adjustable front accommodates square or beveled doors 1" deadbolt throw offers security and strength even with excessive door gaps Highly engineered 3 spring design for smooth, crisp, and responsive operation Heavy-duty, two-piece 3/4" anti-friction latchbolt throw requires less force to close door VR Indicates ML2000VR (Vandal Resistant) availability. ML PAGE 016 Copyright Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited /17

14 Functions Overview ML2000 Series Outside Inside Series/Function Type ANSI No. Function Description A01 A01 ML2002 HSS Classroom Intruder Latchbolt by grip either side, unless outside grip is locked by key either side. Outside grip locked or unlocked by cylinder either side. Auxiliary latch deadlocks latchbolt. Inside grip always free. A01 ML2003 HSS Classroom Lock or unlock outside grip by key. Latchbolt by grip either side, unless outside grip is locked. Inside grip always free. Auxiliary latch deadlocks latch. ML2010 VR HSS Passage or Closet F01 Latchbolt by grip either side. Both grips always free. A01 ML2011 Deadlock F18 VR HSS Deadbolt by key outside. No inside operation. A01 A01 ML2012 Deadlock F16 Deadbolt by key either side. HSS A01 ML2013 Deadlock F17 Deadbolt by key outside or by thumbturn grip inside. HSS A01 ML2017 HSS Classroom Deadlock F29 Deadbolt by key outside. Thumbturn grip inside retracts deadbolt only; will not project deadbolt. ML2020 VR HSS Privacy Bedroom or Bathroom F02 Latchbolt by grip* either side, when deadbolt is retracted. Deadbolt by thumbturn grip inside or by emergency release tool outside. No simultaneous deadbolt and latch retraction Non-panic release Not available with M19S ro M19SN /17 Indicates Indicator option is available Indicates Indicator option is available * When lever handles are furnished, both outside and inside are locked when deadbolt is projected. VR Indicates function available in Vandal Resistant Trim. HSS Indicates function available in Anti-Harm Trim PAGE 017 ML Copyright Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.

15 Functions Overview ML2000 Series A01 A02 A02 Outside Inside Series/Function Type ANSI No. Function Description A02 ML2051 VR HSS ML2052 HSS ML2053 HSS Entrance or Office Classroom Intruder Entrance or Office F04 F32 Latchbolt by key when outside grip locked by toggle action stop. Latchbolt by grip either side, unless outside grip is locked by toggle-action stop. Auxiliary latch deadlocks latchbolt. Inside grip always free. Latchbolt by grip either side, unless outside grip is locked by key either side. Latchbolt by key when outside grip locked. Auxiliary latch deadlocks latchbolt. Inside grip always free. Outside grip remains locked unless unlocked by key either side. Note: Not available with indicator, specify ML2002. Latchbolt by grip either side, unless outside grip is locked or unlocked by key or thumbturn. Unlocked by key or thumbturn. Outside grip locked or unlocked by key or thumbturn. Latchbolt by key when outside grip locked. Auxiliary latch deadlocks latchbolt. Inside grip always free. A01 ML2054 HSS Entrance or Office F04 Latchbolt by grip either side, unless outside grip is locked. Outside grip locked or unlocked by thumbturn. Latchbolt by key when outside grip locked. Auxiliary latch deadlocks latchbolt. Inside grip always free. A02 A02 ML2055 Classroom F05 VR HSS ML2056 HSS Classroom Holdback F06 Latchbolt by grip either side, unless outside grip is locked by key outside Latchbolt by key when outside grip locked Auxiliary latch deadlocks latchbolt Inside grip always free Outside grip remains locked unless unlocked by key Note: Not available with indicator, specify ML2003 Latchbolt by grip either side, unless outside grip is locked or unlocked by key. Latchbolt by key outside when outside grip is locked. Latchbolt can be held in a retracted position by key, or released by key. Auxiliary latch deadlocks latchbolt. Inside grip always free. Note: Not approved for use on U.L. fire listed applications. A01 ML2057 VR HSS Storeroom or Closet F07 Latchbolt by grip inside or by key outside. Outside grip always rigid. Auxiliary latch deadlocks latchbolt. Inside grip always free. A02 ML2058 HSS Entrance or Office Holdback Latchbolt by grip either side, unless outside grip is locked. Outside grip locked or unlocked by key or thumbturn. Latchbolt retracted by key outside when outside grip is locked. Latchbolt can be held in a retracted position by key or thumbturn, or released by key or thumbturn. Auxiliary latch deadlocks latchbolt. Inside grip always free. Note: Not approved for use on U.L. fire listed applications. Indicates rigid grip. VR HSS Indicates function available in Vandal Resistant Trim. Indicates function available in Anti-Harm Trim /17 PAGE 019 ML Copyright Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.

16 Overview Functions ML2000 Series Outside Inside Series/Function Type ANSI No. Function Description A01 ML2059 Security Storeroom or Closet Latchbolt and deadbolt by grip inside or by key outside Inside grip simultaneously retracts deadbolt & latchbolt Outside grip always rigid Auxiliary latch deadlocks latchbolt Inside grip always free ML2060 Privacy F22 HSS Latchbolt by grip either side, except when outside grip is locked by thumbturn inside. Operating inside grip, closing door or operating emergency key outside unlocks outside grip. Inside grip always free. Not available with M19S or M19SN A01 A01 ML2062 Intruder Deadbolt F33 Latchbolt by grip either side, unless outside grip is locked by projection of deadbolt Deadbolt thrown or retracted by key from either side Inside grip simultaneously retracts latchbolt and deadbolt and unlocks outside grip Inside grip always free A01 ML2065 VR Dormitory or Entrance F13 Latchbolt by grip either side unless outside grip locked by projection of deadbolt. Deadbolt thrown or retracted by key outside or by thumbturn grip inside. Inside grip simultaneously retracts latchbolt and deadbolt and unlocks outside grip. Inside grip always free. A01 ML2067 VR Apartment or Dormitory F20 Latchbolt by grip either side, unless outside grip is locked by toggle-action stop or by projection of deadbolt. Deadbolt thrown or retracted by key outside or by thumbturn grip inside. Inside grip simultaneously retracts latchbolt and deadbolt; outside grip remains locked. Auxiliary latch deadlocks latchbolt. Outside grip unlocked by toggle-action stop Note: Occupancy Indicator shows deadbolt position only A01 ML2068 HSS Privacy or Apartment Latchbolt by grip either side, unless outside grip is locked Outside grip locked or unlocked by key or thumbturn Operating inside grip, closing the door or using key unlocks outside grip Inside grip always free Auxiliary latch deadlocks latch A02 ML2069 HSS Institutional Privacy F26 Latchbolt by grip either side, except when outside is locked by thumbturn inside. Operating inside grip or closing door unlocks outside grip. Key outside retracts latch at all times, even if thumbturn is held in locked position. Auxiliary latch deadlocks latchbolt. ML2070 Full Dummy Trim Grips act as pulls only; no operation. Indicates Occupancy Indicator option is available Indicates Indicator option is available ML VR Indicates function available in Vandal Resistant Trim. HSS Indicates function available in Anti-Harm Trim. Indicates rigid grip. PAGE 020 Copyright Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited /17

17 Features ML20900 ECL & ML20600NAC Features Handing Handed; quick reversible. The lockset can be re-handed without disassembling the lockcase. Door Thickness 1-3/4" (44mm) standard. Optional door thicknesses available; see Quick Codes, page 74. Backset 2-3/4" (70mm). Lockcase Heavy-gauge steel, 5-7/8" (149mm) x 4" (102mm) x 15/16" (24mm). Front Heavy gauge steel, 8" (203mm) x 1-1/4" (32mm) x 3/32" (2mm). Accommodates flat doors and doors beveled 1/8" (3mm) in 2" (51mm). Armored Front Wrought brass, bronze or stainless steel attached by machine screws to lockcase front. Latchbolt 2-piece mechanical anti-friction insert, 5/8" (16mm) x l" (25mm) x 3/4" (19mm) throw. Auxiliary Latchbolt 9/16" (14mm) effective throw and 3/8" (10mm) effective auxiliary latch deadlocking. Hub Knob: stainless steel, 9/32" (7mm) x 9/32" (7mm). Lever: steel, 5/16" (8mm). (Including VR ) Spacing C. to c. knob/lever to cylinder: 3-5/8" (92mm) C. to c. knob/lever to thumbturn: 2-7/16" (62mm). Strike Wrought brass, bronze or stainless steel ANSI straight lip standard, 4-7/8" (124mm) x 1-1/4" (32mm) x 1-1/8'' (29mm) lip to center. Optional strikes, lip lengths and ANSI wrought strike box available; see Quick Codes, page 74. Trim Available with all ML2000 Series trim designs including the Vineyard Collection and the Muséo Collection. See pages Cylinder Brass, 6-pin, L4 keyway, 0-bitted standard. Optional cylinders available; see Quick Codes, page 73. Keys Two nickel silver standard. Warranty Ten-year limited warranty on ML2000 mortise lockset. Two-year limited warranty on electronic components. Electrical Specifications (Fail Safe/Fail Secure) 15mA Continuous 12/24VDC Peak current draw =.5A (Maximum of 2 locks per 1A Power Supply) Monitor Switch Rating: 2 24VDC Note: Operating voltage not to exceed +/- 10%. See Quick Codes, page 75. Monitor Options - ML20900 ECL Only M91 - Latchbolt Monitor Latchbolt monitoring is a SPDT switch which monitors the full extension of the main latch. M92 - Request to Exit Monitor Request to Exit monitoring is a SPDT switch which monitors the activation of the trim. (Both levers activate switch) M105 - Security Monitor Security Monitor is two switches in series that monitors lock status (locked or unlocked) and Auxiliary Latch position. Note: Monitoring options may only be ordered together as follows: M91xM92, M92xM105. Monitor Options ML20600 NAC only Internal End-of-Line Monitoring Monitors the line from the access control panel to the lock, eliminating the risk of undetected tampering or damage. PHR Deadbolt Privacy Function Engaging deadbolt disables remote access control unlocking (keypad or card reader) or scheduled unlock. One-piece, corrosionresistant, heavygauge steel front Completely self-contained actuator; lock fits in standard mortise door prep Latch Auxiliary Latch Certification/Compliance ANSI/BHMA Certified A Series 1000, operational and security Grade 1. Meets A117.1 Accessibility Code. Federal Meets FF-H-106C. UL/cUL All locks listed for A label and lesser class doors, 4' x 10' single or 8' x 10' pair. Letter F and UL symbol on armored front indicate listing. Meets requirements of UL1034. Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and Corbin Russwin, Inc. makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing firerated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes and ratings. California State Reference Code (Formerly Title 19, California State Fire Marshal Standard) All levers with returns comply; levers return to within 1/2" of door face. 6-pin solid brass cylinder; Corbin Russwin and competitive cylinder compatibility available Heavy-gauge internal parts Available to match Corbin Russwin trim designs ML PAGE 022 Copyright Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited /17

18 Overview ML20900 ECL ML20900 ECL Series Electrified Mortise Lockset Simplicity Combine simplicity and access control with the Corbin Russwin ML20900 ECL series electrically controlled mortise lock. Utilizing the proven ML2000 Series mortise lockset with the patented quick reversible latchbolt, the ML20900 series provides remote locking and unlocking. The electrified lock can be installed in a standard mortise prep with slight modification by door manufacturer. The ML20900 ECL is ideal for use where increased security is necessary at all times, such as tenant space, pharmacies, computer rooms, and high security areas. Typical Application Wires in Conduit (If Frames Are Filled) Door Cable Security In applications where increased security is required, look no further than the ML2000VR Vandal Resistant Trim. This cast stainless steel trim features tapered edges, double through bolts, torx-pin tamper resistant screws and the lever remains attached to the escutcheon when the spindle is broken. BPS Supply Series Power Supply Power Input Door Control PB Push Buttons Aesthetics Access control doesn t mean a loss of visual appeal. The Vineyard Collection and the Muséo Collection feature beautifully designed levers, perfect for high-profile applications where pleasing aesthetics is a must. Additional Features Mechanical key override Patented Quick Reversible latchbolt, Patent # 6,349,982 Featuring EcoFlex Technology*: Reduces energy consumption up to 96%, as certified by GreenCircle Lower operating costs Assists with load reduction in optimizing energy performance credit in LEED Reduces number of power supplies required Field configurable to fail-safe or failsecure Operates from 12-24VDC, offering greater flexibility in system design Innovative actuator design provides superior reliability Higher performance and reduced maintenance Ability to have longer cable runs without negatively impacting lock function Reduces risk of voltage drops and eliminates inductive kickback Lower total cost of ownership * Patent Pending Mortar Guard (If Frames Are Filled) Electric Thru Wire Hinge EPT EPTL Power Transfers ML20900 ECL /17 PAGE 023 ML Copyright Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.

19 Functions Overview ML2000 ML20900 Series ECL Fail Safe The following functions are unlocked when power is off and locked when the power is on. Outside Inside Series/Function Description ML20907 x SAF VR Latchbolt by grip either side, unless outside grip is locked by energizing lock. Inside grip always free. Auxiliary latch deadlocks latchbolt. ML20915 x SAF VR Latchbolt by grip either side, unless both grips are locked by energizing lock. Auxiliary latch deadlocks latchbolt. A01 ML20914 x SAF VR Latchbolt by grip either side, unless both grips are locked by energizing lock. Latchbolt by key outside when lock is energized. Auxiliary latch deadlocks latchbolt. A01 A01 ML20932 x SAF VR Latchbolt by grip either side, unless both grips are locked by energizing lock. Latchbolt by key inside or outside when lock is energized. Auxiliary latch deadlocks latchbolt. A01 ML20906 x SAF VR Latchbolt by grip either side, unless outside grip is locked by energizing lock. Latchbolt by key outside when lock is energized. Inside grip always free. Auxiliary latch deadlocks latchbolt. Fail Secure The following functions are locked when power is off and unlocked when the power is on. Outside Inside Series/Function Description ML20907 x SEC VR Latchbolt by grip either side only when lock is energized. Outside grip locked when lock is not energized. Inside grip always free. Auxiliary latch deadlocks latchbolt. ML20915 x SEC VR Latchbolt by grip either side only when lock is energized. Both grips locked when lock is not energized. Auxiliary latch deadlocks latchbolt. A01 ML20914 x SEC VR Latchbolt by grip either side only when lock is energized. Both grips locked when lock is not energized. Latchbolt by key outside when lock is not energized. Auxiliary latch deadlocks latchbolt. A01 A01 ML20932 x SEC VR Latchbolt by grip either side only when lock is energized. Both grips locked when lock is not energized. Latchbolt by key inside or outside when lock is not energized. Auxiliary latch deadlocks latchbolt A01 ML20906 x SEC VR Latchbolt by grip either side only when lock is energized. Outside grip locked when lock is not energized. Latchbolt by key outside when lock is not energized. Inside grip always free. Auxiliary latch deadlocks latchbolt /17 Indicates function available in Vandal Resistant Trim. ML Copyright Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. VR PAGE 024

20 Trim Overview Designs ML2000 Series, ML20900 ECL and ML20600 NAC Lustra Complies with codes requiring lever to return to within 1/2" (13mm) of door face. Brass, bronze or stainless steel. LWA Lever: Wrought Rose: Wrought LWB Lever: Wrought Rose: Cast 2-1/4 (57) LSA Lever: Cast Rose: Wrought 2-1/2* (64) 5-1/8 (130) LSB Lever: Cast Rose: Cast LWF Lever: Wrought Rose: Cast LSF Lever: Cast Rose: Cast 2-7/8 (73) 2-1/2* (64) 5-1/8 (130) Dimensions: inches millimeters *Dimension from face of door, not surface of rose or escutcheon. ML PAGE 025 Copyright Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited /17

21 Cylinder and Key Stamping Key Systems VKC and CKC Visual and Concealed Key Control With these options, keys and/or cylinders are stamped with their respective keyset symbol, so lock mix-ups during installation or key mix-ups afterwards are less likely to happen and easier to straighten out if they do. Lost keys are also easier to replace. The coded information on the cylinder tells you how the cylinder is keyed, thereby eliminating trial and error. For example, the symbol AA1 shown in the illustration identifies the lock to be operated by grand master key A, master key AA and change key AA1. Upon written authorization from the building owner to an authorized Corbin Russwin Distributor, a bitting list can be furnished for each job to translate the symbols into key bittings. If a key is lost, it can easily be replaced by referring to the symbol on the cylinder and the bitting on the bitting list. VKC is not available on Security or Pyramid cylinders. Visual Key Control (VKC) For Greater Convenience The key symbol is stamped on the plug face or other visible portion of the front of the cylinder. (VKC is available on all keys, but not available on Security, CK4400 Series Lockset or Pyramid cylinders.) AA1 Concealed Key Control (CKC) For Greater Security For greater security, specify CKC on the cylinders. The key symbol is stamped in a concealed location, such as the rear of the cylinder. It is not visible to the general occupants of the building but can be accessed by authorized personnel upon removing the cylinder from the lockset. The following codes and definitions have been established for specifying cylinder and key stamping: Quick Code Definition VKC0 No keyset, registry number, keyway, nor bitting stamping on any keys. Includes master keys and change keys. (Keys will be tagged.) VKC1 VKC2 Master keys stamped with their keyset symbol and registry number. Change keys stamped with their keyset symbol and keyway.* (Standard for high security and security cylinders.) Master Keys stamped with their keyset symbol and registry number. Change keys stamped with their keyset symbol and keyway.* Cylinders stamped with their keyset symbol on the face of the plug. (Not available for high security or security cylinders.) VKC3 CKC2 CKC3 Master Keys stamped with their registry number. Change keys stamped with their bitting, keyway* and system. Cylinders stamped with their keyset symbol on the face of the plug. (Not available for high security or security cylinders. Master keys stamped with their keyset symbol and registry number. Change keys stamped with their keyset symbol and keyway.* Cylinders stamped with their keyset symbol in a concealed location. Master keys stamped with their registry number. Change keys stamped with their bitting, keyway* and system. Cylinders stamped with their keyset symbol in a concealed location. (Not available for high security, or security cylinders.) *Keyway will NOT be stamped on the keys for security or high security cylinders, nor restricted or protected keyways unless specifically requested as per the purchase order. (KB18, KB19, KB28 or KB90 series) 6 PAGE 029 Copyright Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited /17

22 Conventional Key Systems Mortise Mortise Cylinders For use with all mortise locks and DL3000 Deadlocks. IC: page 15. Security: page 17. Master Ring: page 20. Pyramid: page 24. Type Length Cam Pins Keyway Finish " (see pages 605 (see page 40) 5 (1" length only) (5 pin only) 31-39) /8" (standard) A01 Cloverleaf 6 (standard) /4" A02 Straight 7 (available for 1-1/4"-3") /8" A03 Adams Rite MS and /2" DL3000 Deadlock /4" A04 DL4000 Deadlock " A05 Adams Rite /4" A06 Schlage Cloverleaf /2" A07 DL /4" A62 MR Straight / 900 Series Mullion " A92 Exit Grip Trim 01 & /4" A93 Obsolete deadlocks: Corbin 610 Series and Russwin 1403 Series /2" /4" Flexible Head Mortise Cylinders Use Flexible Head mortise cylinders only with sectional trim mortise locks. The head is spring-loaded to adjust for minor variations in door thickness. See page 20 for Master Ring Type Length Cam Pins Keyway Finish " (6-pin std.) (see page 40) 6 (standard) (see pages 31-39) /8" A01 Cloverleaf 7 (available for 1-1/4"- 1-1/2") /4" A02 Straight Concealed Shell Mortise Cylinders Concealed shell cylinders are for mortise locks using Plug Only to Show escutcheon trim. Type Length Cam Pins Keyway Finish " (6-pin std.) (see page 40) 5 (1" length only) (see pages 31-39) /8" A01 Cloverleaf 6 (standard) /4" A02 Straight /8" /2" 7 (available only for 1-1/4"- 1-1/2") Length Length is measured from behind the cylinder head to the end of the cam. For cam illustrations and applications, see page PAGE 030 Copyright Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited /17

23 Rim Conventional Key Systems Rim Cylinders For use with exit devices and exit device trim. Type Tailpiece Length Pins Keyway Finish /8" 955 and 959 Trims /8" M61 & M62 option for ED8200 and obsolete ED9200 exit device alarms 200 2" (std. door) 200N 2" ED4000/ED5000 Night Latch Function 200V 2" vertical tailpiece /2" (thick door) 312V 3-1/2" vertical tailpiece Tailpiece Orientation std. = Horizontal V = Vertical 6 (standard) 7 (see pages 31-39) Rim Thumbturn Type Tailpiece Length Pins Keyway Finish /8" 200 2" (std. door) N/A N/A /17 PAGE 031 Copyright Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. 13

24 Mortise Cylinder Cams Key Systems Lockset Applications Cams for current products or models Type Part Number Model/Description A01 Reg. IC 756F50 Corbin Russwin Arrow, Marks 5000, PDQ Steel case mortise locks except classroom and institutional privacy functions. Deadbolt functions of green cast iron case mortise locks. NOT for master ring mortise cylinders. All mortise functions using Cloverleaf cam. A02 Reg. IC 756F51 Corbin Russwin Baldwin R. R. Brink Marks Steel case mortise lock classroom (55), inside of vestibule (42) and institutional privacy (69) functions. Most exit device trims. NOT for master ring mortise cylinders. All mortise locks. All except CKS. 7000, 9000 and most brands of older black cast iron locks. A03 Reg. IC 756F52 Corbin Russwin Adams Rite Lori DL3000 Series Cylindrical Deadlocks only Series, 4015 Deadlocks; 4500 and 4700 Series Latch Locks. 4500, 4600 Series Deadlocks. A04 Reg. IC 756F53 Corbin Russwin DL4000 Series Mortise Deadlocks only. A05 Reg. IC 756F54 Adams Rite R. R. Brink 4070 Series Deadlocks. CKS Control Key Switch. A06 Reg. IC 756F55 Schlage L9000 Series (Cloverleaf only). A07 Reg. IC 756F56 Corbin Russwin DL4100 Series Deadbolts A61 Reg. 562F40 Corbin Russwin Mortise Series deadbolt function master ring locks manufactured since June 10, 1993 (silver case). Adapt earlier (gold case) model to use this cam by installing thumbturn hub 562F41-2. A62 Reg. IC 756F58 Corbin Russwin Corbin Russwin DORMA Mortise Series Master Ring classroom (55) function and inside of vestibule (42) function mortise locksets. 900 Series Mullion, WS700 Series Mullion (Both KRM) Mortise Locks A65 Reg. 025F72 Corbin Russwin Mortise Series: required for master ring deadbolt functions manufactured before June 10, 1993 (gold case) and for outside of current vestibule (42) function. Optional for current non-deadbolt functions except classroom (55) and inside of vestibule (42) function. A92 Reg. IC 756F62 Corbin Russwin Concealed vertical rod exit device outside grip handle operators 01 and 02. Cams for obsolete Corbin Russwin products or models A63 121F01 Corbin Russwin Black cast iron case master ring mortise locks, except models with 1" throw deadbolt. A64 135F19 Corbin Russwin Black cast iron case master ring mortise locks with 1" throw deadbolt. Reg. 281F27 A93 Corbin Russwin 610 and 1403 Series Cylindrical Deadlocks. IC 362F43 40 PAGE 032 Copyright Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited /17

25 100 Series concealed overhead door holders/stops Reduced door prep Durable Improved corrosion resistance Function conversion kits are available Materials and finishes 100 Series heavy-duty Glynn-Johnson offers a complete line of overhead door holders and stops, accommodating virtually all openings with solutions for even the most complex door control problems. These concealed holders and stops provide the most attractive and reliable heavy-duty door control available. Glynn-Johnson 100 Series holders and stops provide the most reliable and versatile concealed overhead door control. They are designed for installation on virtually all types of doors mounted on conventional type butt hinges, pivots, continuous hinges, swing clear hinges and numerous other specialty hinges. When used in conjunction with many surface-applied door closers, 100 Series holders and stops provide the most effective control for entrance doors and vestibule doors of all types, as well as heavy or often used interior doors. Templates provided allow for variable mounting positions, ranging from of opening. Five models: 100H Series hold-open model 100HP Series internal hold-open model 100F Series friction hold-open model 100S Series stop-only model 100SE Series special stop-only model Six sizes: Each model comes in six sizes. Simple Standardized Three options: ADJ Adjustable jamb bracket CJ Jamb Bracket for use with LCN 5030 closer SOC Pin-in-socket security screw package Unmatched convenience: Non-handed Improved compatibility with door closers Single/double-acting doors Interior/exterior applications 18 Glynn-Johnson Door holders and stops In heavy gauge brass or 300 Series stainless steel, these models offer the broadest range of finishes in the industry, complementing any design and offering the highest resistance to corrosion. Available in the following finishes: Finishes Description US3 Polished brass US4 Satin brass US10 Satin bronze US10B Oil rubbed bronze US32 Polished stainless steel US32D Satin stainless steel SP4 Powder coat brass SP10 Powder coat bronze SP28 Powder coat aluminum SP313 Powder coat dark bronze SPBLK Powder coat black Models These models provide a wide range of optional features, and are ideal for use on entrance and vestibule doors, large doors, doors opened frequently, or doors subject to abuse. These models are also furnished with an offsetstyle jamb bracket. Designed for heavy-duty applications, 100 Series models will provide long-lasting protection to doors, frames, hinges, related hardware and surrounding walls or obstructions. 100H Series hold-open (Suffix H) The hold-open function should be used where it is desired to hold a door open at a predetermined position for short or long periods of time, permitting an unobstructed traffic flow through the opening. These models are both selective and adjustable, featuring the most reliable hold-open mechanism available. They feature a control knob which protrudes from the face of the door and turns the hold-open function on or off. Set in the inactive position, the unit acts as a stop and shock absorber. The tension on the hold-open mechanism can be adjusted using an allen wrench to offset air currents or other exterior conditions. The hold-open tension adjustment is located in the bottom of the track in the top of the door. PAGE 033

26 100HP Series internal hold-open These models provide a hold-open unit with the hold-open mechanism built into the channel, thus reducing the door prep. The 100HP have a preset hold-open force that is not adjustable. The hold-open feature is not selectable in these units, so the doors are always held open. 100F Series friction hold-open (Suffix F) Friction hold-open models provide an alternative holding method, ideal for heavy patient room doors, closet doors or similar applications where multiple hold-open positions are desired. The friction tension is adjusted using an allen wrench and an open end wrench. The friction tension adjustment is located on the top of the slider in the channel. 100S Series stop-only (Suffix S) When the hold-open function is not required, the stop-only function provides the same effective door control minus the hold-open feature. The stop-only model may be used on fire doors. 100SE Series special stop-only (Suffix SE) When stop-only models are used in conjunction with single point hold-open electronic door closers, they may be ordered without the shock-absorbing mechanism. Used as an auxiliary stop with these closers, they will prolong the life of the closer. The stop location is adjusted using an allen wrench on the stop block located in the channel. Note: Caution should be taken when using this option in other applications, as the elimination of the shock-absorbing spring can put added stress on the door and frame. Application Information UL Classification The 100 Series stop-only models are classified by Underwriters Laboratories (UL) as miscellaneous fire door accessories. This classification applies to use on either hollow metal fire doors or wood fire doors. Where wood door manufacturer s listing allows for the cutout required for installation, concealed overhead stops may be used on those wood fire doors. These units may be used on doors of any rating. As a reminder, the miscellaneous fire door accessories (GVUX) section is defined by UL as: Miscellaneous fire door accessories are intended in the individual listings. The accessories have been investigated to determine that when installed in accordance with the manufacturer s instructions, the accessories do not adversely affect the fire rating of the fire door and/or fire door frames." Dead stop templating If a wall or similar obstruction is in place at 110 or less opening angle (i.e. doors that open back-to-back), dead stop templating should be used. This includes all hold-open, friction and stop-only models, except when the SE option is used. The dead stop position is reached when the shock-absorbing spring is fully compressed, the initial degree of opening will be 5 to 7 less than the dead stop opening. Example: If the holder is templated to a 100 dead stop, the door will hold open at an angle between 93 and 95 but no further than 100. Note: Do not use dead-stop templating on the 100SE Series since there is no shock-absorbing spring. Environmental considerations Environmental factors should always be considered when specifying overhead holders and stops. Doors that are positioned on a building s exterior or subject to corrosive conditions should be equipped with a holder constructed primarily of stainless steel or brass materials. For interior applications, steel is acceptable, though brass substrates generally provide a more attractive architectural-grade finish. Options Suffix ADJ (adjustable jamb bracket) An additional option on the 100 Series is the adjustable jamb bracket, which allows the degree of hold-open or stop angle to be adjusted after installation. Suffix ADJ is available in all functions, but only in sizes 3, 4, 5 & 6. ADJ jamb bracket requires additional frame prep. The ADJ option cannot be added to an existing unit, it must be factory ordered. Suffix CJ (closer jamb bracket) Provides a special jamb bracket needed for 100 Series units used with LCN 5030 closers. These special jamb brackets are handed, so handing will need to be specified when ordering the CJ option, CJLH for a left hand door and CJRH for a right hand door. The CJ option cannot be added to an existing unit, it must be factory ordered. Suffix SOC (Pin-in-socket security screw package) A screw package with pin-in-socket screws for mounting the jamb bracket to the frame is provided instead of the standard screw package. PAGE 034 Glynn-Johnson Door holders and stops 19

27 100 Series concealed overhead door holders/stops 3/4" 1/4" 2" 1" 1-1/4" 1" 1-1/4" 4-1/4" 3/4" 1-1/4" 1" 1/4" 3/8" 1/4" 2-3/8" 5-1/2" 3-1/2" 1/2" 12" 1-1/4" 3/8" 100 Series sizing chart Butts/offset pivots Center hung BHMA/ANSI, A156.8 & Fed. spec. cross reference G-J model BHMA * Fed. spec. Size Door opening Stop only Hold open Friction Note: This chart illustrates the most common types of hinging and door opening sizes. For unusual door details, contact Glynn-Johnson for availability. * These sizes are not available for use with offset pivots. Also not available with the ADJ option. * Wood doors with automatic flush bolts or roller latches, consult factory. Door opening Stop only Hold open Friction 1 18" - 23" 101S * 101H * 101F * " - 27" 102S * 102H * 102F * " - 33" 103S 103H 103F " - 39" 103S 103H 103F " - 39" 104S 104H 104F " - 45" 104S 104H 104F " - 45" 105S 105H 105F " - 51" 105S 105H 105F " - 51" 106S 106H 106F " - 59" 106S 106H 106F H C S C F C * First numeral (0) designates optional material. To specify: Brass material, change 0 to 1 (i.e. C11511) Stainless steel material, change 0 to 5 (i.e. C51511) BHMA: All 100 Series models are designed for heavy-duty applications and far exceed BHMA cycle test and force test requirements for Grade 1 holders and stops. The template information on this page is for reference only and is not intended to serve as an installation template. For complete dimensional information, refer to Glynn-Johnson template book. 20 Glynn-Johnson Door holders and stops PAGE 035

28 How to order 10 4 H US26D ADJ Overhead Series: 10 Size (door opening using butts or offset pivots): 1 (18" - 23") 2 ( " 27") 3 ( " 33") 4 ( " 39") 5 ( " 45") 6 ( " 54") Function: H HP F S SE Finishes: US3 US4 US10 US10B US32 US32D SP4 SP10 SP28 SP313 SPBLK Options: ADJ CJLH CJRH SOC Hold-open Internal hold-open Friction hold-open Stop-only Special stop-only Polished brass Satin brass Satin bronze Oil rubbed bronze Polished stainless Satin stainless steel Powder coat brass Powder coat bronze Powder coat aluminum Powder coat dark bronze Powder coat black Adjustable jamb bracket Special jamb bracket for LCN 5030 closer, LH door Special jamb bracket for LCN 5030 closer, RH door Pin-in-socket security screws PAGE 036 Glynn-Johnson Door holders and stops 21

29 Automatic Flush Bolts Metal Doors A Hinges & Pivots B Pulls & Plates FB31P Top and Bottom Bolts (Pair) Fully Automatic inactive door is latched, bolts are extended when active door closes, door is unlatched, bolts retract when active door is opened. Low Actuation Forces Top Bolt Has No Spring Tension. Fits standard ANSI A115.4 Door Frame Preparations. Non-handed. Bolt throw is 3/4" with a 7/8" vertical adjustment. Bolt backset is 3/4" Standard Rod Length is 12", which is measured from the center of the flush bolt body to the bolt tip. Optional rod lengths available for top bolt only on non-fire rated openings 18", 24", 36" and 48. DP1 or DP2 optional dust proof strike available, see page C11. C2 Flush Bolts & Coordinators D Latches, Catches & Bolts Top Bolt Bottom Bolt Meets ANSI A156.3 Type 25. UL Listed 3 Hour Fire Doors 8'0" x 10'0" FB31T FB31B FB32 FB33 Top Bolt Only Bottom Bolt Only Top Bolt with Auxiliary Fire Latch FB32 Model with Auxiliary Fire Latch eliminates the bottom bolt and is UL Listed for Fire Doors. Top Bolt with Auxiliary Fire Latch and Retrofit Plate FB33 Model with Auxiliary Fire Latch eliminates the bottom bolt and includes a retrofit plate to cover existing bottom bolt prep. UL Listed for Fire Doors. E Stops F Exterior Hardware Top Bolt Auxiliary Fire Latch Meets ANSI A156.3 Type 25. UL Listed 3 Hour Fire Doors 8'0" x 8'0" Dimensions Body Size: 1" Wide x 6-3/4" Long x 2" Deep Guide Size: 1" Wide x 1-27/32" Long x 27/32" High x 3/32" Thick Strike Size: 15/16" Wide x 2-1/4" Long x 1/16" Thick Rub Plate Size: 1-1/4" Wide x 1-11/16" Long x 3/64" Thick Auxiliary Fire Latch Size: 1" Wide x 1-3/4" Long x 3-1/4" Deep Retrofit Plate Size: 1" Wide x 6-3/4" Long x 3/32" Thick Finishes Ives Number US3 US4 US10 US10B US32 US32D BHMA G Miscellaneous Hardware Fire latch only: FBPART.1035 x Finish C2 Ives Architectural hardware products PAGE 037

30 Constant Latching Flush Bolts Metal Doors A Hinges & Pivots B Pulls & Plates C4 Flush Bolts & Coordinators Top Bolt Bottom Bolt Meets ANSI A156.3 Type 27. UL Listed 3 Hour Fire Doors 8'0" x 10'0" FB51P Top and Bottom Bolts (Pair) Constant Latching inactive door remains latched until the active door is opened, releasing the automatic bottom bolt and then the top bolt can be manually released. Inactive door will relatch automatically when closed. Low Actuation Forces. Fits standard ANSI A115.4 Door and Frame Preparations. Non-handed. 3/4" bolt throw with a 7/8" vertical adjustment. 3/4" backset Standard Rod Length is 12", which is measured from the center of the flush bolt body to the bolt tip. Optional rod lengths available for top bolt only on non-fire rated openings 18", 24", 36" and 48". DP1 or DP2 optional dust proof strike available, see page C11. FB51T Top Bolt Only D Latches, Catches & Bolts FB52 FB53 Top Bolt with Auxiliary Fire Latch FB52 Model with Auxiliary Fire Latch eliminates the bottom bolt and is UL Listed for Fire Doors. Top Bolt with Auxiliary Fire Latch & Retrofit Plate FB53 Model with Auxiliary Fire Latch eliminates the bottom bolt and includes a retrofit plate to cover existing bottom bolt prep. UL Listed for Fire Doors. E Stops F Exterior Hardware G Miscellaneous Hardware Top Bolt Auxiliary Fire Latch Meets ANSI A156.3 Type 27. UL Listed 3 Hour Fire Doors 8'0" x 10'0" Dimensions Body Size: 1" Wide x 6-3/4" Long x 2" Deep Guide Size: 1" Wide x 1-27/32" Long x 11/16" High x 3/32" Thick Strike Size: 15/16" Wide x 2-1/4" Long x 1/16" Thick Rub Plate Size: 1-1/4" Wide x 1-11/16" Long x 3/64" Thick Auxiliary Fire Latch Size: 1" Wide x 1-3 4" Long x 3-1/4" Deep Retrofit Plate Size: 1" Wide x 6-3/4" Long x 3/32" Thick Finishes Ives Number US3 US4 US10 US10B US32 US32D BHMA C4 Ives Architectural hardware products PAGE 038

31 Coordinators Bar Coordinators and Filler Bars B Pulls & Plates C12 Flush Bolts & Coordinators A Hinges & Pivots D Latches, Catches & Bolts E Stops Meets ANSI/BHMA A156.3, Type 21A. UL Listed for installation on labeled frame. COR For Openings Where Doors Are Same Size Coordinator Length of For Opening Common Number Channel Widths Applications COR32 32" 34" - 52" Pair of 2'0" Doors COR42 42" 52" - 72" Pair of 2'6" Doors COR52 52" 62" - 92" Pair of 3'0" Doors COR60 60" 70" - 108" Pair of 3'6" Doors COR72 72" 84" - 132" Pair of 4'0" Doors For Openings Where Doors Are Unequal Size The coordinator length should equal the active door width plus approximately 1/2 the inactive door width. The coordinator must be 6" longer than the active door width and shorter than the overall frame opening between stops. FL Series Bar Coodinators The COR Series Coordinators are designed for use on pairs of doors when one door needs to close before the other. All COR units function easily. The active door lever, located nearest to the active stop, holds the active door open until the trigger mechanism is released by the closing of the inactive leaf. All COR units may not function correctly with swingclear hinges. All COR units are equipped with an adjustable override feature which allows the active door to close under extreme pressure. All COR units are compatible with Flush Bolts. The COR Series is available in five sizes for variable door opening widths. The COR Series does not cover the entire length of the stop, so a FL filler bar can be provided to maintain architecturally clean lines. COR Series Coordinator Channels and FL fillers are made of aluminum. Optional Filler Bars: FL20-20", FL32-32" and FL44-44", available to maintain clean line. Optional Mounting Brackets available: MB1, MB2, MB1F, MB2F, MB3F, MB1V, MB2V, and MB3V for other stop applied hardware. Finishes Ives Finish US28 US26D 315AN BHMA Series Filler Bars The FL Filler Bars are available in three sizes for variable frame openings. FL Filler Bars are made of aluminum FL Filler Bars are field sized to frame opening. Filler Bar Number Length Dimensions F Exterior Hardware FL20 20" 1-5/8" W x 5/8" D x 20" L FL32 32" 1-5/8" W x 5/8" D x 32" L FL44 44" 1-5/8" W x 5/8" D x 44" L Finishes Ives Finish US28 US26D 315AN BHMA G Miscellaneous Hardware C12 Ives Architectural hardware products PAGE 039

32 4040SE Series Features The 4040SE SENTRONIC is a heavy duty, non-handed, nonsized closer/holder designed to provide single point hold-open for fire and smoke barrier doors. The door is held open until current interruption releases the holding mechanism and the door closes. Single lever (track) arm closer is specifically designed for interior doors. Choice of finishes, track functions, and installation accessories meet virtually all life safety requirements. Certifications Body Construction Fluid Handing Grade 1 - ANSI A156.15, UL 10C, ADA, 100 Hour Salt Spray, Meets BAA - Buy American Act, NFPA 101 n Cast Iron Body n Full Complement Bearing n 1-1/2 Diameter Piston n 3/4 Diameter Double Heat Treated Pinion Journal All Weather Fluid Non-Handed Size Adjustable Spring Size, up to 4 Warranty 2 years Cover Fasteners Mounting Arms Finishes/Colors/ Powder Coat Wiring n Clip-on plastic, standard n Metal, optional Wood and machine screw pack Hinge (Pull Side), Stop Face (Push Side) Standard arm and SE track, standard Double egress arm and SEL track, optional n Aluminum (689) n Statuary Bronze (690) n Light Bronze (691) n Black (693) n Dark Bronze (695) n Brass (696) n Custom colors optional n Optional SRI primer - powder coat only n Optional plated finishes Concealed or surface, interfaces with fire alarm systems Special Templates Customized installation templates or products may be available to solve unusual applications. Contact LCN Product Support for assistance. HINGE (PULL) SIDE TOP JAMB (PUSH) STOP FACE (PUSH) MOUNTING FINISH COVER CYLINDER *ARM FUNCTION CONCEALED (DOOR) CONCEALED (FRAME) POWDER COAT PLATED PLASTIC METAL HANDED NON-SIZED SIZED SINGLE POINT HOLD-OPEN MULTI-POINT HOLD-OPEN BYPASS 80/140 STANDARD (SINGLE) REGULAR (DOUBLE) SWING FREE DOUBLE EGRESS AVAILABLE NOT AVAILABLE * Maximum opening/hold-open point with standard template. See individual closer series for degrees of opening per installation. LCN Door Control Catalog phone: n fax: n n rev. 11/16 PAGE 047 E15

33 4040SE Series Mounting details Hinge (Pull) Side Mounting 3-1/2" 89 mm 22-3/4" 578 mm 1-1/2" 38 mm 3-1/2" 89 mm 1-1/16" 27 mm 2-1/4" 57 mm 1-1/4" 32 mm 5/16" 8 mm 12-1/4" 311 mm Butt Hinges Swing Clear Hinges Auxiliary Stop Reveal Top Rail Head Frame Flush Ceiling Door Width Should not exceed 5 (127 mm) in width Consult factory Recommended at hold-open point n Should not exceed 1/8 (3 mm) for standard arm n Should not exceed 2-11/16 (68 mm) for double egress arm n Minimum 3-1/2 (89 mm) n Installation with PLATE, 4040SE-18 requires SPECIAL TEMPLATE and 1-3/4 (44 mm) minimum top rail Requires 2 (51 mm) minimum 2 (51 mm) head frame does not require special templating n 2 4 (711 mm) minimum for single door with SE n 4 8 (1422 mm) minimum for paired doors with SE Flush Ceiling 2-3/8 (60 mm) behind door required for 90 installation Maximum Opening n Templating allows 110 n Hold-open points between 85 and 110 in approximately 3 increments n Pull side mounting on a double egress frame requires a handed double egress arm n Maximum hold-open to 95 n 2-11/16 (67 mm) maximum reveal on pull side n SEL track provides hold-open points between 90 and 120 in approximately 3 increments SE, SEL Electrical Options Options SE Wiring Diagram n These track assemblies require a single power circuit for the holding solenoid n SE or SEL holding solenoid is either 24V or 120V input, please specify n An optional 4040SE-3210 or TRANSFORMER reduces 120V AC line voltage to 24V AC. n Circuitry accepts either AC or DC input n Long (SEL) track n Handed double egress arm for reveal under 2-11/16 (67 mm) See FIRE/LIFE SAFETY section page 19 for typical wiring and electrical diagram Notes: Information applies to 4040 SE unless otherwise specified Hold-open force is adjustable Momentary on/off switch board assembly for testing door release also provides over-voltage protection. Field replaceable Functions as a full rack and pinion closer when hold-open is not engaged or current is interrupted E16 LCN Door Control Catalog phone: n fax: n n rev. 11/16 PAGE 048

34 4040SE Series Mounting details Stop Face (Push Side) Mounting 3-7/8" 98 mm 22-3/4" 578 mm 3-1/2" 89 mm 5-3/16" 132 mm 1-1/16" 27 mm 2-1/4" 57 mm 1-1/4" 32 mm 3-3/4" 95 mm 12-1/4" 311 mm Butt Hinges Auxiliary Stop Top Rail Stop Width Door Width Should not exceed 5 (127 mm) in width Recommended at hold-open point n Minimum 5-3/4 (146 mm) n Installation with PLATE, 4040SE-18PA requires SPECIAL TEMPLATE and 2 (51 mm) minimum top rail 1-1/4 (32 mm) minimum n 2 4 (711 mm) minimum for single door with SE n 4 8 (1422 mm) minimum for paired doors with SE Maximum Opening n Templating allows 110 n Hold-open points between 85 and 110 in approximately 3 increments n SEL track provides hold-open points between 90 and 120 in approximately 3 increments SE, SEL Electrical Options Options SE Wiring Diagram n These track assemblies require a single power circuit for the holding solenoid n SE or SEL holding solenoid is either 24V or 120V input, please specify n An optional 4040SE-3210 or TRANSFORMER reduces 120V AC line voltage to 24V AC n Circuitry accepts either AC or DC input n Long (SEL) track To either terminal INPUT WIRES To either terminal Green ground Terminal Notes: Information applies to 4040 SE closers unless otherwise specified Momentary on/off switch board assembly for testing door release also provides over-voltage protection. Field replaceable Functions as a full rack and pinion closer when hold-open is not engaged or current is interrupted LCN Door Control Catalog phone: n fax: n n rev. 11/16 PAGE 049 E17

35 Three Knuckle Standard Weight Series The full mortise bearing hinge is recommended for standard weight, medium frequency doors, or doors with closing devices. Use for the common flush door/frame/wall application Decorative tips are available For available finishes see page 29 TA314 TA714 Full Mortise Bearing Hinges No. ANSI Cross Reference Base Material Weight TA314 A5112 Stainless STD TA314 A2112 Brass STD TA714 A8112 Steel STD Application Specifications Inches mm Gauge No. of Holes Machine Fasteners Wood 3 1 / 2" x 3 1 / 2" * 88.9 x / 2 x x 10 4" x 4"* x / 2 x / 4 x / 2" x 4" x / 2 x / 4 x / 2" x 4 1 / 2" x / 2 x / 4 x 12 5" x 4 1 / 2" * 127 x / 2 x / 4 x 12 5" x 5"* 127 x / 2 x / 4 x 12 * Not available in Brass Base material Options: Code Description NRP Non-Removable Pin RC Round Corner 1 / 4" radius furnished unless specified otherwise HT Hospital Tip Decorative Tip Options FT Flat Tip RT Round Tip GT Grooved Tip LT Lined Tip BT Ball Tip ST Steeple Tip Note: Not available on 3 1 /2 " x 3 1 /2" hinges FT GT RT LT SSF Safety Stud Feature QC ElectroLynx Hinge 2, 4, 6, 8, 10 or 12 wire available CC Concealed Circuit 2, 4, 6, 8, 10 or 12 wire available CC-18 Concealed Circuit 2, 4, 6, 8 or 10 wire available (2-18AWG wires and the remainder 28AWG wires) MM Magnetic Monitoring BT ST Check the web site for the up-to-date catalog McKinney is a brand associated with Corbin Russwin, Inc., an ASSA ABLOY Group company. Copyright , Corbin Russwin, Inc. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. PAGE 058 FM-3

36 Full Mortise Bearing Hinges Three Knuckle Heavy Weight Series Recommended for use on high frequency and/or heavy wood or metal doors in schools, hospitals or other public buildings where heavy traffic is experienced. Heavy weight hinges should be used on all extra heavy doors or those exposed to high frequency use Use for the common flush door/frame/wall application Beveled Edge - where doors are beveled on hinge side specify TA5386 or TA5786 For available finishes see page 29 Decorative flat tips are available on 4 1 / 2" and 5" TA386 TA786 No. ANSI Cross Reference Base Material Weight Application TA386 A5111 Stainless HVY TA386 A2111 Brass HVY TA786 A8111 Steel HVY Specifications Inches mm Gauge No. of Holes Machine Fasteners Wood 4 1 / 2" x 4" x / 2 x / 4 x / 2" x 4 1 / 2" x / 2 x / 4 x 12 5" x 4 1 / 2" 127 x / 2 x / 4 x 12 5" x 5"* 127 x / 2 x / 4 x 12 6" x 5"* x / 2 x / 2 x 14 6" x 6"* x / 2 x / 2 x 14 * Not available in Brass Base material. Options: Code Description NRP Non-Removable Pin RC Round Corner 1 / 4" radius furnished unless specified otherwise HT SSF Hospital Tip Safety Stud Feature QC ElectroLynx Hinge 2, 4, 6, 8, 10 or 12 wire available CC Concealed Circuit 2, 4, 6, 8, 10 or 12 wire available CC-18 Concealed Circuit 2, 4, 6, 8 or 10 wire available (2-18AWG wires and the remainder 28AWG wires) MM FT Magnetic Monitoring Flat Decorative Tip FM Check the web site for the up-to-date catalog PAGE 059 McKinney is a brand associated with Corbin Russwin, Inc., an ASSA ABLOY Group company. Copyright , Corbin Russwin, Inc. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.

37 ElectroLynx Hinge (QC option) Each hinge features concealed plug connectors that eliminate the need for separate or exposed wiring. Standard connectors make installation quick and simple. Brass eyelets add protection and durability. Electrified Hinges The QC option is available on standard and heavy weight full mortise bearing hinges as well as swing clear and wide throw hinges QC-12 Electric hinges allow a constant flow of current from the power source through the hinge to electrified door hardware. No external wires can be seen, eliminating tampering and improving the aesthetics of the door opening Materials: brass, stainless steel, and steel For 4 amp 24 volts AC or DC per circuit, 28 gauge multi-strand wires are used. A pigtail is provided for connection to the source wiring An 8 position connector is used for QC2, QC4, QC6 and QC8 wire hinges. An 8 position and a 4 position connector is used for QC12 wire hinges. A QC2A wire hinge is available for power on, power off applications Hand of hinge must be specified on two knuckle hinges Can be used in conjunction with MM option on most full mortise hinges. QC10 x MM and QC12 x MM not recommended for wood or solid core doors Full Mortise QC hinges are available in most BHMA and McKinney powder coat finishes Wires are coordinated to work with other ASSA ABLOY Group brands electro-mechanical hardware * Electric hinges should be installed in the center position on the door. Installation instructions are packed with each hinge. * Hinges are factory tested and specially packaged to minimize against damage during shipment. Application Pigtail assembly Male connector Back of 12 wire hinge shown Options: Female connector 3-Knuckle TA314 TA714 TA386 TA786 5-Knuckle TA2314 TA2714 T4A3386 T4A3786 TA2895 T4A3395 T4A3795 Most hinges including this Swing Clear Hinge can be electrically modified. Call for more information. Code QC2A QC2 QC4 QC6 QC8 QC10 QC12 Description 1 circuit 1 circuit 2 circuits 3 circuits 4 circuits 5 circuits 6 circuits Check the web site for the up-to-date catalog McKinney is a brand associated with Corbin Russwin, Inc., an ASSA ABLOY Group company. Copyright , Corbin Russwin, Inc. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. PAGE 060 EH-1

38 electrified hinges Check the web site for the up-to-date catalog ElectroLynx Retrofit Cables If you are not ordering ASSA ABLOY Door Group doors with the ElectroLynx cable pre-installed in the door, you must order an ElectroLynx retrofit cable to go between ANY hardware and the hinge. This includes 3" cables to go from the hinge to an exit device and up to a 15' cable to go up and around a full lite metal door. Standard ElectroLynx Retrofit Cable Sizes Actual Cable Length 12 Conductor and Molex both ends 3" QC-C003 QC-C003P 6" QC-C006 QC-C006P 12" QC-C012 QC-C012P 26" QC-C200 QC-C200P 32" QC-C206 QC-C206P 38" QC-C300 QC-C300P 44" QC-C306 QC-C306P 50" QC-C400 QC-C400P 15' 2" QC-C1500 QC-C1500P 25' - QC-C2500P 30' - QC-C3000P 12 Conductor and Molex one end, pinned one end Typical Application Between hinge and the end of an exit device. Between hinge and through the door to the lockset or exit device trim. From the hinge location, up the jamb to above the ceiling, or up and around full lite or half lite metal door. Custom lengths available. ElectroLynx As part of their promise to provide innovative, fast and effective high security solutions to their customers, certain ASSA ABLOY Group brands offer ElectroLynx, a universal quick-connect system that simplifies the electrification of the door opening. ElectroLynx is a registered trademark of ASSA ABLOY Inc. EH-2 McKinney is a brand associated with Corbin Russwin, Inc., an ASSA ABLOY Group company. Copyright , Corbin Russwin, Inc. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. PAGE 061

39 IN120 Intelligent WiFi Access Control The Corbin Russwin IN120 pairs a sleek, attractive design with the latest in access control technology to address the evolving needs of today s facilities. Featuring multiclass SE technology from HID Global, this innovative WiFi lock makes it easy and affordable to expand your access control system. PAGE 062

40 Specifications and System Requirements Credential Support: 2.4 GHz credentials: - Secure Identity Object (SIO) on Mobile IDs (Bluetooth Smart) MHz credentials: - iclass - iclass SE (SIO-enabled) - iclass Seos - SIO on MIFARE Classic - SIO on MIFARE DESfire EV1 - MIFARE Classic - DESfire EV1 - NFC-enabled mobile phones 125 khz credentials: - HID Prox Operating Power: 6 AA batteries or 12-24VDC hard power option Security: AES 128-bit encryption Supports current WiFi network security standards, including: - WEP, WPA and WPA x (e.g. EAP, PEAP, PAP) Software Options: ASSA ABLOY IP-Enabled Access Control Partner software SDK and support available to integrate into other third party access control systems (contact: OEMSupport_Group@assaabloy.com) EAC Regulatory Compliance: UL294 6th Edition CAN/ULC S319 BHMA A IN120 Intelligent WiFi Access Control Features Utilizes IEEE WiFi infrastructure multiclass SE Technology from HID Global Field-upgradable b/g/n radio Customizable feature set Intelligence built into lock for local decision making Privacy button Field selectable communication frequency Integrated ANSI/BHMA Grade 1 hardware, available in cylindrical lock, mortise lock, and exit device configurations Available with a wide range of finishes and decorative levers Benefits Significantly reduces installation costs Eliminates the need for any proprietary equipment Ideal for hard-to-wire locations Provides heightened security Supports: Multiple credential technologies, offering easy migration to higher security credentials or consolidation of mixed credentials HID Mobile Access powered by Seos, for both ios and Android devices Interoperability with other WiFi equipment Future proof for constantly evolving WiFi standards Select only the features you need Add features as your requirements grow Lock operates regardless of network status Supports up to 2,400/10,000 users* Provides a 10,000 event transaction history/audit trail Enables shelter in place / local lockdown Offers privacy capabilities for applications such as restrooms Allows you to balance security requirements with battery life * Contact your access control system manufacturer for more information Flexibility to support various openings Assurance of high quality hardware Blends into any environment seamlessly Designed to meet the requirements of designers and architects Typical System Configuration b/g/n Wireless Access Point Installed by ASSA ABLOY CERTIFIED INTEGRATOR Sold through ASSA ABLOY AUTHORIZED CHANNEL PARTNER Corbin Russwin Architectural Hardware 225 Episcopal Road Berlin, CT Phone Fax corbinrusswin.com EAC Server Copyright , Corbin Russwin Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. PAGE 063 HID, iclass, iclass SE, and multiclass SE are registered trademarks or trademarks of HID Global in the U.S. and/or other countries. The Genuine HID Technology logo is a trademark owned and licensed by HID Global /16

41 IN120 Functions Sold through: ASSA ABLOY AUTHORIZED CHANNEL PARTNER ML20100 Mortise Locks Series/Function Type Function Description ML20133 No Key Override No Deadbolt ML20134 With Key Override No Deadbolt ML20135 No Key Override With Deadbolt ML20136 With Key Override With Deadbolt Entry Entry Entry Entry Deadlocking latch Latch retracted by inside lever at all times Outside lever rigid except when in "passage" mode or valid user code entered Deadlocking latch Latch retracted by inside lever at all times Outside lever rigid except when in "passage" mode or valid user code entered Key outside retracts latch No deadbolt function Deadlocking latch Latch and deadbolt retracted by inside lever at all times Outside lever rigid except when in "passage" mode or valid user code entered Deadlocking latch Latch and deadbolt retracted by inside lever and deadbolt at all times Outside lever rigid except when in "passage" mode or valid user code entered Key outside projects or retracts deadbolt and retracts latch ML20200 Mortise Locks Series/Function Type Function Description ML20233 No Key Override No Deadbolt ML20234 With Key Override No Deadbolt ML20235 No Key Override With Deadbolt 1 ML20236 With Key Override With Deadbolt 1 Entry Entry Entry Entry Deadlocking latch Latch retracted by inside lever at all times Outside lever rigid except when in "passage" mode or valid user code entered Deadlocking latch Latch retracted by inside lever at all times Outside lever rigid except when in "passage" mode or valid user code entered Key outside retracts latch No deadbolt function Deadlocking latch Latch and deadbolt retracted by inside lever at all times Outside lever rigid except when in "passage" mode or valid user code entered Deadlocking latch Latch and deadbolt retracted by inside lever and deadbolt at all times Outside lever rigid except when in "passage" mode or valid user code entered Key outside projects or retracts deadbolt and retracts latch 1 Deadbolt required for escape return functionality (a residential requirement in Canada) CL33100 Cylindrical Locks Series/Function Type Function Description CL33134 With Key Override Entry Latch retracted by inside lever at all times. Key outside retracts latch. Outside lever locked (freewheeling) except when in passage mode or valid user code entered /15 Copyright Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. 1

42 PAGE 073

43 PAGE 074

44 smart Magnalocks durable magnalocks Specialty locks exit devices entry devices access control accessories power supplies power transfer Product features Ultra-secure collapsing blind nuts mount to door frame for strength and reliability Fully sealed for weatherproof operations 10 ft. [3.05m] of jacketed, stranded conductor cable Automatic dual voltage - no field adjustment required Instant release circuit - no residual magnetism Noise suppression with included MOV Efficient, low power usage Rust resistant - All ferrous metal surfaces plated for durability Fits in 2.5" of flat mounting space MagnaCare Lifetime Replacement No Fault Warranty Product options (B) BondSTAT magnetic bond sensor Patented (MBS) (D) Integrated door position switch (DPS) (G) Universal threaded conduit fitting is 1/2" female 3/4" male (Gate conduit) (F) Face drilled Split Strike Plates and Offset Strike Plates Specifications UL 10C Listed CAN4-S104, CAN/ULC-S533 Listed ANSI/UL 294 Listed CSA-C22.2 No.205 Listed ANSI/BHMA A156.23, Grade 1; E CSFM- California State Fire Marshal Approved MEA City of New York Approved CE:EN (92), EN (99) Approved Patent: 8,094,017 Holding Force: 1200lbs. [544kg] Dimensions: Magnalock: 8"L x 1-3/4"D x 3"H Strike: 6"L x 1/2"D x 2-3/4"H Electrical: 250mA at 12VDC 150mA at 24VDC Operating Temperature: -40 to +140F [-40 to +60C] Indoor or Outdoor use Shipping Weight: 11lbs [5kg] Finishes: US32D/630 - Satin Stainless Steel M62 SERIES 1200lbs Holding Force The Ultimate in Magnalock Versatility for Indoor/Outdoor Higher Security The M62 is a strong, easy-to-maintain solution for interior, perimeter and exterior access control. With unsurpassed durability, the M62 will last long after most buildings wear out. Flexible mounting options support applications for hollow metal, concrete filled metal, wood, or glass with aluminum frames, and Herculite doors. Options include single and double door configurations, or specialty applications such as gates and fences. models PART # Description M62 M62 Magnalock- 12/24VDC M62B M62 Magnalock- 12/24VDC, MBS M62BD M62 Magnalock- 12/24VDC, MBS, DPS M62D M62 Magnalock- 12/24VDC, DPS M62F M62 Magnalock- 12/24VDC, Face Drilled M62FB M62 Magnalock- 12/24VDC, Face Drilled, MBS M62FBD M62 Magnalock- 12/24VDC, Face Drilled, MBS, DPS M62FD M62 Magnalock- 12/24VDC, Face Drilled, DPS M62FG M62 Magnalock- 12/24VDC, Face Drilled, Gate Conduit M62FGB M62 Magnalock- 12/24VDC, Face Drilled, Gate Conduit, MBS M62FGBD M62 Magnalock- 12/24VDC, Face Drilled, Gate Conduit, MBS, DPS M62FGD M62 Magnalock- 12/24VDC, Face Drilled, Gate Conduit, DPS M62G M62 - Gate Conduit M62GB M62 - Gate Conduit, MBS M62GBD M62 - Gate Conduit, MBS, DPS M62GD M62 - Gate Conduit, DPS For dress covers and flexible mounting brackets, see page 26. 8" [203mm] power accessories 3" [76mm] 1-3/4" [44mm] 1/2" [12mm] 6" [152mm] 2-3/4" [70mm] resources PAGE MAGLOCK SECURITRON.COM 2015, Hanchett Entry Systems, Inc., an ASSA ABLOY Group company.

45 MAGNECTIC LOCK MOUNTING ACCESSORIES Electromagnetic locks (maglocks) can be installed on various frames and doors using accessory pieces. To figure out what you need for a maglock install, first measure the door stop. Most maglocks require 2-1/4" to 2-1/2" of flat mounting space for the mounting bracket or direct mount. You may need one or more accessories if the door stop is less than 2-1/2". 2-1/4" to 2-1/2" Securitron s M38, M68, M32, M380 and M680 Magnalocks fit in 2-1/4" of flat mounting space. Securitron s M62, DM62 and M82 Magnalocks fit in 2-1/2" of flat mounting space. What maglock accessories does your door need? ALUMINUM SHIM BRACKETS (ASB) For aluminum doors Used when the blade stop requires the maglock to be lowered Available for M32, M62 and M82 only STOP FILLER PLATES (SFP) For steel and wood frames Fills or extends a door stop Available in 1/4", 3/8", 1/2" and 5/8" thicknesses UNIVERSAL HEADER BRACKET (UHB) Extends the header 1" to 1-1/2" to create enough header to mount the magnet Provides concealed wiring chamber MAGLOCK SECURITRON.COM PAGE 084

46 MAGNECTIC LOCK MOUNTING ACCESSORIES What maglock accessories does your door need?(continued) CONCRETE/ WOOD BRACKET (CWB) For concrete filled metal frames and wood frames Easier to install than blind nuts Heavy duty wood and metal fasteners included Available for M32, M62 and M82 only HEADER EXTENSION BRACKET (HEB) 90 degree angle brackets Extends narrow headers to permit maglock mounting Sample Stop Filler Plate (SFP) and Concrete/Wood Bracket (CWB) combination Sample Stop Filler Plate (SFP) and Universal Header Bracket (UHB) combination Accessories are available in clear aluminum or black anodized finish. Verify length of magnetic lock before ordering mounting accessories. Z BRACKETS AND TOP JAMB (TJ) BRACKETS Use on in-swing doors Use Z bracket with face mount maglocks Use Top Jamb bracket with bracket mounted maglocks Dress covers in clear anodized, black anodized or satin stainless TJ and Z Brackets SMC MAGLOCK SECURITRON.COM PAGE 085

47 SMART MAGNALOCKS DURABLE MAGNALOCKS SPECIALTY LOCKS EXIT DEVICES ENTRY DEVICES SB-1» SEX BOLT REPLACEMENT Replaces armature plate sex bolt for M32, M38, M62, M68, and M82B Magnalocks Available in clear, polished brass or oil rubbed bronze finish MagnaCare lifetime replacement, no fault warranty MODELS PART # Description SB-1 Sex Bolt - Replacement, Clear SB-1-03 Sex Bolt - Replacement, Polished Brass SB-1-10B Sex Bolt - Replacement, Oil-Rubbed Bronze ACCESSORIES for M32/62/82 Magnalocks DDC» DOUBLE DRESS COVERS Available in clear and black finish For use with a pair of Magnalocks on a double door separated by no more than 2" Not for use with the DM62 Magnalock MagnaCare lifetime replacement, no fault warranty MODELS DDC-32BK DDC-32CL DDC-62BK DDC-62CL DDC- M32, Black Anodized DDC - M32, Clear Anodized DDC - M62, Black Anodized DDC - M62, Clear Anodized PART # Description ACCESS CONTROL ACCESSORIES POWER SUPPLIES POWER TRANSFER POWER ACCESSORIES DC» DRESS COVERS Use with M32, M62, and M82 Install using foam adhesive tape Available in clear, black, polished stainless and polished brass finish MagnaCare lifetime replacement, no fault warranty MODELS DC-32BK DC - M32, Black Anodized DC-32BP DC - M32, Brass Polished DC-32CL DC - M32, Clear Anodized DC-32SP DC - M32, Stainless Polished DC-62BK DC - M62, Black Anodized DC-62BP DC - M62, Brass Polished DC-62CL DC - M62, Clear Anodized DC-62SP DC - M62, Stainless Polished DC-82BK DC - M82, Black Anodized DC-82BP DC - M82, Brass Polished DC-82CL DC - M82, Clear Anodized DC-82SP DC - M82, Stainless Polished PART # Description RESOURCES PAGE MAGLOCK SECURITRON.COM 2016, Hanchett Entry Systems, Inc., an ASSA ABLOY Group company.

48 Product features 1, 4 or 8 outputs protected with polyswitch (PTC) 2A circuit breakers LEDs provide an easy-to-read voltage indicator for output zone status (voltage, no voltage) Slide switches connect or disconnect load from power (excludes 1 Amp) Battery charging and backup capability (battery sold separately, see page 120) Rugged steel enclosure Fire alarm relay connection for release of all devices upon fire alarm activation Clean linear power for flawless operation with all sensitive active electronic components MagnaCare Lifetime Replacement No Fault Warranty Specifications ANSI/UL 294 Listed CSA-C22.2 No.205 Listed MEA City of New York Approved Electrical: Input Voltage: 120VAC Operating Temperature: +32 to +105F [0 to +40C] Shipping Weight: BPS-12-1, BPS-24-1: 9lbs [4.08kg] BPS-12-3, BPS-24-2: 15lbs [6.80kg] BPS-12-45, BPS-24-3: 18lbs [8.16kg] BPS-12-6, BPS-24-4: 24lbs [10.89kg] BPS-12-9, BPS-24-6: 28lbs [12.70kg] BPS-12-15, BPS-24-10: 33lbs [14.97kg] BPS Boxed Power Supply 12VDC or 24VDC Linear Output for High Performance The BPS series single voltage power supplies deliver linear technology recommended by most manufacturers of sensitive electronic access control and security components. Safe for use with readers, electric strikes, and maglocks, these units interface to fire alarm systems and provide battery backup. The BPS power supplies provide 12VDC or 24VDC output with a variety of amp sizes that support small or large power needs. models BPS-12-1 BPS-12-3 BPS BPS-12-6 BPS-12-9 BPS BPS-24-1 BPS-24-2 BPS-24-3 BPS-24-4 BPS-24-6 BPS PART # Description Power Supply - 12VDC, 1 AMP Power Supply - 12VDC, 3 AMP Power Supply - 12VDC, 4.5 AMP Power Supply - 12VDC, 6 AMP Power Supply - 12VDC, 9 AMP Power Supply - 12VDC, 15 AMP Power Supply - 24VDC, 1 AMP Power Supply - 24VDC, 2 AMP Power Supply - 24VDC, 3 AMP Power Supply - 24VDC, 4 AMP Power Supply - 24VDC, 6 AMP Power Supply - 24VDC, 10 AMP See accessories on page 106. smart magnalocks durable magnalocks Specialty locks exit devices entry devices access control accessories 12VDC Capacity 24VDC Capacity Cabinet Size bps Amp bps Amp 12" x 9" x 4" 1 Outputs power supplies bps Amp bps Amp 14" x 14" x 4" 4 bps Amp bps Amp 14" x 14" x 4" 4 bps Amp bps Amp 15" x 18" x 6" 8 bps Amp bps Amp 15" x 18" x 6" 8 bps Amp bps Amp 15" x 18" x 6 " 8 power transfer power accessories BATTERY BACKUP 2015, Hanchett Entry Systems, Inc., an ASSA ABLOY Group company. PAGE 087 SECURITRON.COM MAGLOCK 87 resources

49 98/99 Series Exit devices PAGE 088

50 Nomenclature how to order None SD CD CX E QEL EL LX RX RX2 SS AX PL PN WS XP WS None WDC WDC AD DT EO HL K K-BE K-DT K-NL L L-BE L-DT L-NL NL NL-OP TL TL-BE TP TP-BE Standard Special dogging R/VR - panic only Cylinder dogging - panic only Chexit Electric locking mortise/lever Quiet electric latch retraction Electric latch retraction Latch bolt monitoring Request to exit Double request to exit Signal switch Accessible device Pullman latch Pneumatic latch retraction Surface vertical rod exit device Heavy protection - rim Tornado & hurricane tested Series 98-smooth Series 99-grooved Rim device Surface mounted vertical rod device Concealed vertical rod device Concealed vertical rod wood door device Concealed vertical rod device Concealed vertical cable device Concealed vertical cable wood door device Three-point latch device Mortise lock device AD Trim (to come from client) Dummy trim Exit only Hospital pull trim Knob Knob - blank escutcheon Knob, rigid - dummy trim Knob, rigid - night latch Lever (classroom) Lever - blank escutcheon Lever, rigid - dummy trim Lever, rigid - night latch Night latch Night latch cylinder assembly, optional pull Turn lever Turn lever - blank escutcheon Thumbpiece Thumbpiece - blank escutcheon EL L -16 -F LBR 3' US3 RHR XX F Lever style 06 standard Optional 01, 02, 03, 05, 07, 12 (Handed), 16 (Omega), 17, 18, Accent, Asti, Merano, St. Annes Fire exit device -2 Double cylinder (rim & mortise only) LBR LBL SG ALK ALK-AR1 ALK-AR3 ALK-AR6 CON Less bottom rod Less bottom latch Safety glow (luminescent) touchpad Alarm kit Auto-reset 1 1 /2 minute alarm kit Auto-reset 3 minute alarm kit Auto-reset 4 1 /2 minute alarm kit Allegion Connect 2' 3' 4' 2' Device (2' door size) 27, 47 or 49 only 3' Device (2' 4" 3' door size) 4' Device (2' 10" 4' door size) Finishes US3, US4, US10, US26, US26D, US28, 313, 315 US32D 98 ONLY -AM Antimicrobial (available US26D and US32D) -LHR -RHR Left hand reverse Right hand reverse PAGE 089 Von Duprin 98/99 Series 5

51 Lever styles Decorative levers M51 Knurling available M52 Knurling available M53 M54 M55 M56 M57 M61 (Handed) M62 (Handed) M63 (Handed) M81 Knurling available M82 M83 M84 M85 (Handed) Available in Stainless Steel substrate ONLY. Standard Levers Knurling available 03* Knurling available 05 06* Default lever Knurling available (Handed) 16 (Omega) 17* Knurling available 18 ACC (Accent) (Handed) AST (Asti) (Handed) MER (Merano) (Handed) LAT* Latitude LON* Longitude *Available in Stainless Steel - specify SS when ordering PAGE 090 Von Duprin 98/99 Series 7

52 98/99 Rim exit device The 299 Strike ships standard, optional strikes available 98 and 99 Rim exit devices for all types of single and double doors with mullion, UL listed for panic exit hardware. Devices are ANSI A Grade 1. The 98 device has a smooth mechanism case and the 99 device has a grooved case. The rim device is non-handed except when the following device options are used: SD (special dogging), -2 (double cylinder) or SS (signal switch). See Opposite page for available outside trim and device functions. Covers stock hollow metal doors with 86 or 161 cutouts on single doors (may cover cutouts on pairs consult template). Hex key dogging comes standard on 98/99 Rim exit devices Finishes US3, US3A, US4, US4A, US10, US26, US26D, US26D-AM Antimicrobial, US28, 313, 315 & 643E. US15 and US32D available with 98 Series only. 98/99 Rim exit device Specifications Device functions Device ships EO/DT/NL. Field selectable. For TP, K or L remove NL drive screw from device. Device lengths 3' 2'4' to 3' (711mm to 914 mm) Door size 4' 2'10" to 4' (864 mm to 1219 mm) Door size Device centerline from finished floor Center case dimensions Mechanism case dimensions Projection Latch bolt Fasteners & sex bolts (SNB) /16" (1011 mm) /16" (1008 mm) with mullion 8" x 2 3 /4" x2 3 /8" (203mm x 70mm x 60mm) 2 1 /4" x 2 1 /4" (57mm x 57mm) Pushbar neutral 3 13 /16" (97 mm) Pushbar depressed 3 1 /16" (78 mm) Deadlocking, 3 /4" (19mm) throw Includes screw pack for 1 3 /4" (44mm) and 2 1 /4" (57mm) thick metal or wood doors. Optional 425 SNB available, see page 9 for quantities. Electric options LX Latchbolt monitor switch RX Pushpad monitor switch RX2 Double pushpad monitor switch E Electric locking & unlocking trim EL Electric latch retraction QEL Quiet electric latch retraction SS Signal switch CX Chexit delayed exit ALK Alarm exit kit WP-RX Waterproof request to exit CON Allegion Connect Mechanical -2 Double cylinder options AX Accessible device GBK Glass bead kit PN Pneumatic latch retraction XP Extra protection SNB Sex bolts SEC Security screws Dogging feature Hex key dogging standard Dogging options CD Cylinder dogging SD Special center case dogging LD Less dogging DI Dogging indicator CI Cylinder dogging indicator Strikes 299 Dull black XP Extra protection 90 latch-tostrike contact Force resistance of 2,000+ lbs. QEL Quiet electric latch retraction Bolt retraction via switch Converts exit door to push-pull operation CX Chexit delayed exit Meets NFPA 101 requirements Self-contained controls, locking, alarm EL Electric latch retraction Enables remote unlatching Alternative to manual dogging PN Pneumatic latch retraction For areas where electrical devices banned Special linkage for mechanical or pneumatic dogging CD Cylinder dogging Replaces hex key dogging Requires 1 1 /4" mortise cylinder with inverted cam RX Pushpad monitor switch Signals use of an opening SPDT switch to monitor pushpad AX Accessible device UL certified to meet new 5 lb. maximum operating force requirement Exceeds ANSI/ BHMA requirements ALK Alarm exit kit Unauthorized opening triggers 85-decibel horn Set in armed or disarmed mode by key CON Allegion Connectors Common connectors to connect various door hardware all the way to the power supply 8 Von Duprin 98/99 Series PAGE 091

53 Standard trim EO DT NL NL-OP Product description Trim description Escutcheon plate size No outside trim Exit only 98EO 99EO Dummy trim Pull when dogged 98DT 99DT Night latch Key retracts latchbolt 98NL 99NL 990DT 990NL-R/V 3" x /16" x 3 /32" (76x360x2mm) 3" x /16" x 3 /32" (76x360x2mm) Pull center to center 5 1 /2" (140mm) 5 1 /2" (140mm) Projection 2" (51mm) 2" (51mm) ANSI function Cylinder type Rim Rim Handing Optional trim x990eo x996eo Optional #425 SNB quantity for device Product description x996k-dt x996l-dt x696dt x697dt x996k-nl x996l-nl x696nl x697nl Lever Key locks & unlocks 98L 99L Lever night latch Key retracts latchbolt 98L-NL 99L-NL Lever blank escutcheon Always operable (no cylinder) 98L-BE 99L-BE Night latch Key retracts latchbolt optional pull required 98NL-OP 99NL-OP 110NL-MD 110NL-WD Lever dummy trim pull when dogged 98L-DT 99L-DT Trim description 996L-R/V* 996L-NL-R/V 996L-BE-R/V* 996L-DT Escutcheon plate size L L-NL L-BE L-DT 2 3 /4" x 10 3 /4" x 27 /32" (70x273x21mm) 2 3 /4" x 10 3 /4" x 27 /32" (70x273x21mm) 2 3 /4" x 10 3 /4" x 27 /32" (70x273x21mm) 2 3 /4" x 10 3 /4" x 27 /32" (70x273x21mm) Pull center to center Projection 2 7 /8" (73mm) 2 7 /8" (73mm) 2 7 /8" (73mm) 2 7 /8" (73mm) ANSI function Cylinder type Rim Rim Handing Handed/Reversible Handed/Reversible Handed/Reversible Handed/Reversible Optional #425 SNB quantity for device * Electrified lever operation available 98/99 Rim exit device Notes PAGE 092 Von Duprin 98/99 Series 9

54 98-F/99-F Rim exit device The 299F Strike ships standard, optional strikes available 98-F and 99-F Rim fire exit devices for all types of single doors up to 4' x 10' (1219mm x 3048mm) or 8' x 10' (2438mm x 3048mm) double doors with 9954 or 9854 mullion, UL listed for fire exit hardware. See page 76 for detailed information on UL listed fire exit hardware label and door opening size information. Devices are ANSI A Grade 1. The 98-F device has a smooth mechanism case and the 99-F device has a grooved case. The rim device is non-handed except when the following device options are used: -2 (double cylinder) or SS (signal switch). See opposite page for available outside trim and device functions. Finishes US3, US3A, US4, US4A, US10, US26, US26D, US26D-AM Antimicrobial, US28, 313, 315 & 643E. US15 and US32D available with 98 Series only. 499F Strike with 9854/9954 mullion 98-F/99-F Rim exit device Specifications Device functions Device ships EO/DT/NL. Field selectable. For TP, K or L remove NL drive screw from device. Device lengths 3' 2'4' to 3' (711mm to 914 mm) Door size 4' 2'10" to 4' (864 mm to 1219 mm) Door size Device centerline from finished floor Center case dimensions Mechanism case dimensions Projection Latch bolt Fasteners & sex bolts (SNB) /16" (1011 mm) /16" (1008 mm) with mullion 8" x 2 3 /4" x2 3 /8" (203mm x 70mm x 60mm) 2 1 /4" x 2 1 /4" (57mm x 57mm) Pushbar neutral 3 13 /16" (97 mm) Pushbar depressed 3 1 /16" (78 mm) Deadlocking, 3 /4" (19mm) throw Includes screw pack for 1 3 /4" (44mm) and 2 1 /4" (57mm) thick metal or wood doors. Optional 425 SNB available for metal doors. 425 & 825 SNB required on wood doors without SLM blocking. See page 11 for quantities. Electric options LX Latchbolt monitor switch RX Pushpad monitor switch RX2 Double pushpad monitor switch E Electric locking & unlocking trim EL Electric latch retraction QEL Quiet electric latch retraction SS Signal switch CX Chexit delayed exit ALK Alarm exit kit WP-RX Waterproof request to exit CON Allegion Connect Mechanical -2 Double cylinder options AX Accessible device GBK Glass bead kit PN Pneumatic latch retraction XP Extra protection SNB Sex bolts SEC Security screws SLM Special Laminate Material Blocking Dogging option No mechanical dogging. EL and QEL option available Strikes 299F Dull black, 499F with mullions XP Extra protection 90 latch-tostrike contact Force resistance of 2,000+ lbs. EL Electric latch retraction Enables remote unlatching Alternative to manual dogging QEL Quiet electric latch retraction Bolt retraction via switch Converts exit door to push-pull operation AX Accessible device UL certified to meet new 5 lb. maximum operating force requirement Exceeds ANSI/ BHMA requirements PN Pneumatic latch retraction For areas where electrical devices banned Special linkage for mechanical or pneumatic dogging RX Pushpad monitor switch Signals use of an opening SPDT switch to monitor pushpad ALK Alarm exit kit Unauthorized opening triggers 85-decibel horn Set in armed or disarmed mode by key CX Chexit delayed exit Meets NFPA 101 requirements Self-contained controls, locking, alarm SG Safety glow Shows exit door location in darkness or smoke Developed to meet MEA standards CON Allegion Connectors Common connectors to connect various door hardware all the way to the power supply 10 Von Duprin 98/99 Series PAGE 093

55 Standard trim EO DT NL NL-OP Product description Trim description Escutcheon plate size No outside trim Exit only 98EO-F 99EO-F Dummy trim Pull when dogged (not recommended for fire device) 98DT-F 99DT-F Night latch Key retracts latchbolt 98NL-F 99NL-F 990DT 990NL-R/V 3" x /16" x 3 /32" (76x360x2mm) 3" x /16" x 3 /32" (76x360x2mm) Pull center to center 5 1 /2" (140mm) 5 1 /2" (140mm) Projection 2" (51mm) 2" (51mm) ANSI function Cylinder type Rim Rim Handing Optional trim x990eo x996eo #425 SNB optional - HMD req. WD w/o SLM pkg. #825 SNB req. WD w/o SLM pkg. #425 SNB req. w/ 499F x996k-dt x996l-dt x696dt x697dt x996k-nl x996l-nl x696nl x697nl (if using trim) L L-NL L-BE L-DT Night latch Key retracts latchbolt optional pull required 98NL-OP-F 99NL-OP-F 110NL-MD 110NL-WD 98-F/99-F Rim exit device Product description Lever Key locks & unlocks 98L-F 99L-F Lever night latch Key retracts latchbolt 98L-NL-F 99L-NL-F Lever blank escutcheon Always operable (no cylinder) 98L-BE-F 99L-BE-F Trim description 996L-R/V* 996L-NL-R/V 996L-BE-R/V* 996L-DT Escutcheon plate size 2 3 /4" x 10 3 /4" x 27 /32" (70x273x21mm) 2 3 /4" x 10 3 /4" x 27 /32" (70x273x21mm) 2 3 /4" x 10 3 /4" x 27 /32" (70x273x21mm) Lever dummy trim pull when dogged (not recommended for fire device) 98L-DT-F 99L-DT-F 2 3 /4" x 10 3 /4" x 27 /32" (70x273x21mm) Pull center to center Projection 2 7 /8" (73mm) 2 7 /8" (73mm) 2 7 /8" (73mm) 2 7 /8" (73mm) ANSI function Cylinder type Rim Rim Handing Handed/Reversible Handed/Reversible Handed/Reversible Handed/Reversible #425 SNB optional - HMD req. WD w/o SLM pkg. #825 SNB req. WD w/o SLM pkg. 2 (if using trim) #425 SNB req. w/ 499F * Electrified lever operation available PAGE 094 Von Duprin 98/99 Series 11

56 9827-F/9927-F Surface Mounted Vertical Rod Fire Device Top latch 299 Top strike 9827-F/9927-F Surface mounted vertical rod device 9827-F/9927-F Fire exit surface mounted vertical rod device pairs of doors up to 8' x 10' (2438mm x 3048mm), UL listed for fire exit hardware. See page 76 for detailed information on UL listed fire exit hardware label and door opening size information. Devices are ANSI A Grade 1. The 9827-F device has a smooth mechanism case and the 9927-F device has a grooved case. The surface vertical rod device is non-handed except when the following device options are used: SS (signal switch), and WS (Tornado/Hurricane). See opposite page for available outside trim and device functions. Vertical rod and latch guards are available to protect the bottom rod of the exit device from damage by impacts of carts or gurneys passing through doors. Rod and latch guards can be used on hollow metal or tin clad composite fire doors. Finishes US3, US4, US10, US26, US26D, US28 & 313. US15 and US32D available with 98 Series only. Specifications Device functions 22 Von Duprin 98/99 Series Device ships EO/DT/NL. Field selectable. For TP, K or L remove NL drive screw from device. Device lengths 2' 2' (610 mm) Door size 3' 2'4' to 3' (711mm to 914 mm) Door size 4' 2'10" to 4' (864 mm to 1219 mm) Door size Device centerline 39 5 /8" (1006 mm) from finished floor Center case 8" x 2 3 /4" x2 3 /8" (203mm x 70mm x 60mm) dimensions Mechanism case 2 1 /4" x 2 1 /4" (57mm x 57mm) dimensions Projection Pushbar neutral 3 13 /16" (97 mm) Pushbar depressed 3 1 /16" (78 mm) Latch bolt Deadlocking anti-friction top & bottom bolt, 5 /8" (16mm) throw Door undercut 1 /4" (7mm) recommended Top & bottom 4 1 /2" x 2 1 /8" x 1 1 /2" (114mm x 54mm x 38mm) Latch case Vertical rods 1 /2" square tubing, standard rods accommodate 7' (2134mm) doors. Top rod length: /16" (887mm); Bottom rod length: 31 1 /2" (794mm) Extension rods available in 1' (205mm) or 3' (914mm) for doors over 7'. One piece top rod is available for 8' (2438mm) and 10' (3048mm) doors. Fasteners & sex bolts (SNB) Includes screw pack for 1 3 /4" (44mm) to 2 1 /4" (57mm) thick metal or wood doors, and 325 SNB for top and bottom latch. Optional 425 SNB available. Electric options LX Latchbolt monitor switch RX Pushpad monitor switch RX2 Double pushpad monitor switch E Electric unlocking and locking trim EL Electric latch retraction QEL Quiet electric latch retraction SS Signal switch CX Chexit delayed exit ALK Alarm exit kit WP-RX Waterproof request to exit CON Allegion Connect Mechanical GBK Glass bead kit options PN Pneumatic latch retraction LBR Less bottom rod PL Pullman latch WS Tornado and hurricane tested SNB Sex bolts SEC Security screws SLM Special laminate material blocking Dogging option No mechanical dogging. EL and QEL option available Strikes Top 299F (499F LBR) Dull black, Bottom 304L - Unfinished WS Windstorm Severe weather certified/tested FEMA and ICC compliant Tornado & hurricane tested QEL Quiet electric latch retraction Bolt retraction via switch Converts exit door to push-pull operation EL Electric latch retraction Enables remote unlatching Alternative to manual dogging E (E996L) Electrified breakaway lever Electrified remote locking/unlocking Standard in fail safe condition PN Pneumatic latch retraction For areas where electrical devices banned Special linkage for mechanical or pneumatic dogging 499F Top strike - LBR 304L Bottom strike Bottom latch RX Pushpad monitor switch Signals use of an opening SPDT switch to monitor pushpad ALK Alarm exit kit Unauthorized opening triggers 85-decibel horn Set in armed or disarmed mode by key CX Chexit delayed exit Meets NFPA 101 requirements Self-contained controls, locking, alarm LBR Less bottom rod Available with UL Fire Label For pairs of vertical rod devices CON Allegion Connectors Common connectors to connect various door hardware all the way to the power supply PAGE 095

57 Standard trim EO DT NL NL-OP TL TL-BE Product description Trim description Escutcheon plate size No outside trim Exit only 9827EO-F 9927EO-F Dummy trim Pull when dogged (not recommended for fire device) Night latch Key retracts latchbolt 9827NL-F 9927NL-F 990DT 990NL-R/V 3" x /16" x 3 /32" (76x360x2mm) 3" x /16" x 3 /32" (76x360x2mm) Night latch Key retracts latchbolt optional pull required 9827NL-OP-F 9927NL-OP-F 110NL-MD 110NL-WD Thumbturn Key locks & unlocks (use with DT trim) 9827TL-F 9927TL-F 374T X 990DT 1 11 /16" x 7 1 /2" x 7 /8" (43x191x22mm) Thumbturn Blank escutcheon always operable (no cylinder) (use with DT trim) 9827TL-BE-F 9927TL-BE-F 374T-BE X 990DT 1 11 /16" x 7 1 /2" x 7 /8" (43x191x22mm) Pull center to center 5 1 /2" (140mm) 5 1 /2" (140mm) Projection 2" (51mm) 2" (51mm) 2" (51mm) 2" (51mm) ANSI function or Cylinder type Rim Rim 1 1 /4" Mortise Handing Optional trim x990eo x996eo Optional #425 SNB quantity for device Product description x996k-dt x996l-dt x696dt x697dt x996k-nl x996l-nl x696nl x697nl Lever Key locks & unlocks 9827L-F 9927L-F Lever night latch Key retracts latchbolt 9827L-NL-F 9927L-NL-F Lever blank escutcheon Always operable (no cylinder) 9827L-BE-F 9927L-BE-F Trim description 996L-R/V* 996L-NL-R/V 996L-BE-R/V* 996L-DT Escutcheon plate size L L-NL L-BE L-DT 2 3 /4" x 10 3 /4" x 27 /32" (70x273x21mm) 2 3 /4" x 10 3 /4" x 27 /32" (70x273x21mm) 2 3 /4" x 10 3 /4" x 27 /32" (70x273x21mm) Lever dummy trim pull when dogged (not recommended for fire device) 2 3 /4" x 10 3 /4" x 27 /32" (70x273x21mm) Pull center to center Projection 2 7 /8" (73mm) 2 7 /8" (73mm) 2 7 /8" (73mm) 2 7 /8" (73mm) ANSI function Cylinder type Rim Rim Handing Handed/Reversible Handed/Reversible Handed/Reversible Handed/Reversible Optional #425 SNB quantity for device * Electrified lever operation available 9827-F/9927-F Surface mounted vertical rod device Notes PAGE 096 Von Duprin 98/99 Series 23

58 98/99 Electrical options RX Request to exit The RX (2xit) feature is used to signal the use of an opening. This device is equipped with one internal SPDT switch which monitors the pushpad. The device can be connected to a security console, or may be used as a single door alarm when used with a horn and power supply. The RX switch option should not be used to control a load, but as a signalling switch (0.5 amps. resisitive maximum). The RX switch is available in a low current (LC) switch. Most commonly used in computer operated monitoring systems. To order, specify: Standard use prefix RX, example RX99EO Low Current use prefix RX-LC, example RX-LC98EO RX2 Double request to exit The RX2 feature uses two RX switches. To order, specify: Standard Use prefix RX2, example RX299EO WP-RX Waterproof request to exit LX Latchbolt monitoring The LX feature is used to signal the use of an opening. This device is equipped with one internal SPDT switch which monitors the latch bolt. The device can be connected to a security console, or may be used as a single door alarm when used with a horn and power supply. The LX switch option should not be used to control a load, but as a signalling switch (0.5 amps. resistive maximum). SS Signal switch Monitors pushpad and latch bolt The SS feature is used to signal the unauthorized use of an opening. This device is equipped with two internal SPDT switches. One switch monitors both the pushpad and the latch bolt assembly, making the latch bolt tamper resistant, for positive security. An additional SPDT switch is connected to the 1 1 /4" (32mm) mortise cylinder with straight cam for alarm bypass. (Schlage cam reference B ). The device can be connected to a security console, or may be used as a single door alarm when used with a horn and power supply. Pushpad reads: Emergency Exit ONLY Push To Open And Sound Alarm. Pushpad is only available in US32D finish with red silk-screened lettering. The SS mortise lock device is furnished with both the signal switch device and the SS7500 mortise lock. The SS7500 mortise lock has the versatility and advantages of the 7500 lock with the addition of signalling functions to monitor latch bolt operation and the trim locking function. The SS7500 mortise lock is supplied standard with the SS mortise lock device. To order, specify: 1. Prefix SS, example SS99L. 2. Handing required, LHR or RHR. Electrical ratings: Up to VDC Popular SS application Unauthorized use of this opening will activate the local horn. The key switch permits inhibiting this system for authorized entry. Electrical options & accessories The LX switch is available in a low current (LC) switch. Most commonly used in computer operated monitoring systems. To order, specify: Standard Use prefix LX, example LX99EO Low Current Use prefix LX-LC, example LX-LC98EO Electrical rating for all switches: Standard 2 Amp 24VDC Low Current (LC) - below 50 24VDC Note: All switches can be either factory or field installed PAGE 097 Von Duprin 98/99 Series 61

59 98/99 Chexit device CX The Chexit (with motor driven blocking actuator) * Minimum door opening sizes for CX devices Electrical options & accessories The Von Duprin Chexit device is designed for controlled egress applications. It meets both life safety and security needs, as well as the requirements of NFPA 101 for "Special Locking Arrangement" and IBC "Special Egress-Control Devices". All control inputs, auxiliary locking, local alarm and remote signaling outputs are self-contained in the Chexit assembly. Numerous configurable options allow the device to be customized for the specific code or application requirements. The standard Chexit device sounds an alarm and keeps the door secured for 15 seconds following an exit attempt with immediate release upon fire. The Chexit device includes a 6" x 20" decal for application on door. PUSH UNTIL ALARM SOUNDS. DOOR CAN BE OPENED IN 15 SECONDS Chexit typical applications Chexit single door with options The Chexit is used as an access control device. The card reader allows access. Also shown in this application is an external horn and door position switch. The auxiliary horn is used for increased volume in remote locations. Using a door position switch gives added security to the opening in case the door is not reclosed. With the Chexit disarmed, the opening functions as a normal exit device. If card readers are required on both sides of the door, the normally closed contacts of the readers should be wired in series. To fire alarm contact To secure status Gang group (optional) Remote Alarm 2 x 14 AWG 8 x 18 AWG 2 x 18 AWG 2 x 18 AWG 1 x 18 AWG 2 x 18 AWG Junction box EPT10 Chexit 2 x 14 DPS ** 902, 904, 906, or 914 Power supply Figure 1. Riser Diagram, Single Door AC input (See power supp for AC input requ 2 x 18 AWG (plus power if required) 2 x 18 AWG Card Reader Figure 1. Riser Diagram, Single Door **Note: PS902 is not to be used for double door Chexit applications. Consult factory for other size requirements. Device 3' (914mm) Length 4' (1219mm) Length CX98/98-F/99/99-F 2'10 3 /4" (883mm) 3'4 3 /4" (1035mm) CX-XP98/XP98-F/XP99/XP99-F 2'10 3 /4" (883mm) 3'4 3 /4" (1035mm) CX9827/9827-F/9927/9927-F 2'10 1 /4" (870mm) 3'4 1 /4" (1022mm) CX9847/9847-F/9947/9947-F 2'10 1 /4" (870mm) 3'4 1 /4" (1022mm) CX9848/9848-F/9948/9948-F 2'10 1 /4" (870mm) 3'4 1 /4" (1022mm) CX9849/9849-F/9949/9949-F 2'10 1 /4" (870mm) 3'4 1 /4" (1022mm) CX9850/9850WDC-F/ 2'10 1 /4" (870mm) 3'4 1 /4" (1022mm) 9950/9950WDC-F CX9857/9857-F/9957/9957-F 2'10 1 /4" (870mm) 3'4 1 /4" (1022mm) CX9875/9875-F/9975/9975-F 2'10 1 /4" (870mm) 3'4 1 /4" (1022mm) Specifications / Power supply requirements * Input voltage 24VDC Input current inrush 1.25A Input current holding 390mA Alarm relay and Secure relay contact ratings 24VDC, 1A Fire alarm, Inhibit and Door position switch inputs require normally closed dry contacts. Power supply information for CX devices with motor driven blocking actuator *. Power supply PS902 (up to 2 amps) PS904 (up to 4 amps) PS906 (up to 6 amps) PS914 (up to 4 amps) Maximum number of devices 1 Chexit device 3 Chexit devices 4 Chexit devices 4 Chexit devices When powering multiple components, verify that the amperage requirements of all components combined does not exceed the power supply output rating, see table above for output ratings. Consult Installation Instructions for proper wire gauge and wire run requirements. Exceeding the recommended devices and/or not following Installation Instructions may void your warranty. Call Customer Care at or visit the Allegion website for more information - How to order * To order, specify: 1. Prefix product description number CX. Example: CX99L 2. Specify option (see options on page 60). Example: CX-RCM or CD-CX 3. Door size other than 3' (914mm). 4. Door thickness other than 1 3 /4" (45mm). 5. Finish. 6. Handing, LHR or RHR. Required with CD option. *Note: Chexit devices built after August 24, 2015 are built using motor driven blocking actuators that have decreased power supply and operating requirements. The information listed in this catalog references the power supply and operating requirements that are needed for the new products with motor driven blocking actuators. For information on devices built previous to August 24, 2015, please contact Customer Care at Von Duprin 98/99 Series PAGE 098

60 98/99 Chexit, RCM and DE5300 features The Chexit, Remote Chexit Module (RCM) or DE5300 devices have several features and options available to fit your applications. See below for more information. Inputs & Outputs Fire Alarm Input This input releases the door immediately upon a fire alarm allowing immediate egress. The Internal Alarm can be silenced during a fire input via an onboard switch setting. Inhibit Input (Access Control) This optional input is provided to allow authorized egress or entry when the device is Armed using an external card reader, Key Switch, etc. It also allows remote reset of the Chexit, RCM or DE5300 in an alarmed condition. The ability to reset alarms with the inhibit input can be disabled via an onboard switch setting. Door Position Switch Input An optional Door Position Switch (DPS) can provide door position status to Chexit, RCM or DE5300 for additional security, ensuring that the door is closed, and can cause alarm when the door is left or forced open. Gang Bus The Gang bus allows a Chexit, RCM or DE5300 device to signal other Chexit, RCM or DE5300 devices when it enters the Release Delay, allowing multiple doors to release at the same time in an emergency. Up to 8 devices may be connected to the Gang Bus. Alarm Relay Contacts The Alarm Relay contacts are provided as a means to control a Remote Alarm, such as a horn or lamp, or signal an external monitor. The contacts can be configured with a jumper as Normally Open or Normally Closed, and become active upon entering an alarmed condition. Secure Relay Contacts The Secure Relay contacts are provided as a means to signal an external monitor. The contacts can be configured as Normally Open or Normally Closed with a jumper, and become active when the DPS indicates the door is closed and the Push Pad is locked. Delays Release Delay When the Push Pad is pushed and the Nuisance Delay expires, the Chexit, RCM or DE5300 enters the Release Delay with alarm. During the Release Delay, the Internal Alarm sounds, the Alarm Relay activates, and the Chexit/RCM keeps the Push Pad or DE5300 magnetic lock, locked for 15 seconds (less any time already elapsed during the Nuisance Delay). Once started, the Release Delay sequence will not stop and the devices will unlock. Nuisance Delay When a Chexit, RCM or DE5300 is located in a public area, it can be desirable to limit false releases when the Push Pad is accidently pushed. The Nuisance Delay is the brief time a Push Pad can be accidently pushed before the Release Delay sequence starts. If the Nuisance Time is set to 0 seconds the Chexit, RCM or DE5300 will enter Release Delay as soon as the Push Pad is pushed (when armed). Setting the Nuisance Time to 1, 2, or 3 seconds allows the Push Pad to be pressed for 1 to 3 seconds before the Chexit, RCM or DE5300 goes into Release Delay. If the Nuisance Audio and Nuisance Delay are both on, the Internal Alarm will pulse during the Nuisance Delay. The Alarm Relay does not activate during the Nuisance Delay. If the Push Pad is released before the Nuisance Delay expires, the Chexit, RCM or DE5300 will remain armed. Rearm Delay The Rearm Delay is the amount of time after the Key Switch or Inhibit Input is deactivated to when the device rearms. It is designed to give someone time to pass through the door before rearming occurs. The Rearm Time can be changed via the onboard switch settings from 0 and 28 seconds in 2 second increments. If the Rearm Time is set to 30 seconds and a DPS is used, if the door is opened and the Rearm Time expires, there will be no alarm. The Chexit, RCM or DE5300 will rearm after the door is closed. If the door never opens, the Chexit, RCM or DE5300 will rearm after 30 seconds. If not using a DPS, the Chexit, RCM or DE5300 will always rearm in 30 seconds. DPS Delay If the DPS detects that the door closed during the Rearm Delay, the Chexit, RCM or DE5300 ends the Rearm Delay and allows 2 seconds for the latch to clear the strike before rearming. Interface Key Switch The Key Switch provides the means to Arm or Disarm/Reset the Chexit, RCM or DE5300. Turning the Key Switch clockwise initiates the Rearm Delay, and turning the Key Switch counterclockwise Disarms/Resets the Chexit, RCM or DE5300. The Key Switch allows the key to be removed in either the Arm or the Disarm/Reset position. Status Indicator The red Status Indicator displays the status of the Chexit, RCM or DE5300. The Status Indicator flashes slow if the Chexit, RCM or DE5300 is armed, flashes fast in an alarmed mode, is off when inhibited and on solid during Rearm Delay. Internal Alarm The Internal Alarm sounds the status of the Chexit, RCM or DE5300. The Internal Alarm sounds continuously during and after a fire alarm or a Release Delay, pulses fast during the Nuisance Delay or a tamper and pulses slow during Disarmed Powerup mode. Settings Armed Powerup When set to OFF, a power disruption and power return will put the Chexit, RCM or DE5300 in a disarmed, unlocked alarm mode. Trim Fail Safe / Fail Secure (FS/FSE) The trim input power can be set to FS (Fail Safe; locked when energized, unlocked when deenergized or during power failure) or FSE (Fail Secure; unlocked when energized, locked when deenergized or during power failure). The trim must be bought or modified to physically function as FS or FSE. This on board setting only selects the trim input power. Electrical options & accessories PAGE 099 Von Duprin 98/99 Series 63

61 98/99 Chexit options DE5300 Delayed Egress System Electrical options & accessories RCM Remote Chexit Module is designed to provide the concept of the Chexit delayed exit system for door sizes smaller than the standard Chexit device can accommodate. The Chexit module is installed in a control box and mounted in a remote location. Features and functions of the standard Chexit exit device are available on the Remote Chexit Module. RCM Module Minimum door opening sizes for RCM devices Consult factory for other size requirements. Device Cylinder dogging Special center case cylinder dogging option is available to allow push/pull operation of the Chexit, when disarmed and used in a heavy traffic area. Prefix device with CD and specify handing. 1¹ ₁₆" (27 mm) Maximum X Standard cam configuration (Shown with key removed) 3' (914mm) Length 4' (1219mm) Length CX-RCM 98/98-F/99/99-F 2'5" (737mm) 2'11" (889mm) CX-RCM XP98/XP98-F/XP99/XP99-F 2'5" (737mm) 2'11" (889mm) CX-RCM 9827/9827-F/9927/9927-F 2'4 1 /2" (724mm) 2'10 1 /2" (876mm) CX-RCM 9847/9847-F/9947/9947-F 2'4 1 /2" (724mm) 2'10 1 /2" (876mm) CX-RCM 9848/9848-F/9948/9948-F 2'4 1 /2" (724mm) 2'10 1 /2" (876mm) CX-RCM 9849/9849-F/9949/9949-F 2'4 1 /2" (724mm) 2'10 1 /2" (876mm) CX-RCM 9850/9850WDC-F/ 2'4 1 /2" (724mm) 2'10 1 /2" (876mm) 9950/9950WDC-F CX-RCM 9857/9857-F/9957/9957-F 2'4 1 /2" (724mm) 2'10 1 /2" (876mm) CX-RCM 9875/9875-F/9975/9975-F 2'5 1 /2" (743mm) 2'11 1 /2" (902mm) Specifications / Power supply requirements * Size 3.75" x 5.57" x 2.50" Input voltage 24VDC Input current inrush 1.25A Input current holding 390mA Alarm relay and Secure relay contact ratings 24VDC, 1A Fire alarm, Inhibit and Door position switch inputs require normally closed dry contacts. Cylinders Cylinders are not furnished with the Chexit device and must be specified when ordering. Use 1 1 /4 mortise cylinder with compression ring K with straight cam and orient cam as shown. Schlage cylinder recommended for the device and the CD cylinder dogging option. See Schlage Pricebook for additional information. DE5300 Delayed Egress System is designed for controlled egress applications when used in conjunction with a magnetic lock. It meets both life safety and security needs, as well as the requirements of NFPA for "Special Locking Arrangement" and IBC "Special Egress-Control Devices". All control units, auxiliary locking, local alarm and remote signaling outputs are selfcontained in the DE5300 assembly. DE5300 Module The DE5300 is commonly used on narrow stile doors where a standard or narrow stile Chexit is not practical. DE5300 Delayed Exit System uses a Chexit logic board and a Von Duprin RX-LC (low current request to exit) panic device to control a Schlage Electronics Direct Hold Magnetic Lock. The Chexit module for the DE5300 is installed in a control box and mounted in the wall adjacent to the door. Features and functions of the standard Chexit exit device are available on the DE5300. The DE5300 device includes a 6" x 20" decal for application on door. PUSH UNTIL ALARM SOUNDS. DOOR CAN BE OPENED IN 15 SECONDS Cylinders Cylinders are not furnished with the DE5300 and must be specified when ordering. Use 1 1 /4 mortise cylinder with compression ring K with straight cam and orient cam as shown. Schlage cylinder recommended for the device and the CD cylinder dogging option. See Schlage Pricebook for additional information. Specifications / Power supply requirements Size " x 5.57" x 2.50" Input voltage 24VDC Input current 1A Alarm relay and Secure relay contact ratings 24VDC, 1A Fire alarm, Inhibit and Door position switch inputs require normally closed dry contacts. How to order To order, specify: 1. DE M420/P, M450/P, or M490/P magnetic lock (order direct from Schlage Electronics). 3. RX-LC 22/33A/35A/98/99 device. 4. PS900 Series 5. EPT-2/10 To fire alarm contact 2 x 18 AWG To secure status 2 x 18 AWG 2 x 18 Remote Alarm 2 x 18 AWG Junction box 902, 904, 906, or 914 Power supply 2 x 18 AWG (plus power if required) 5 x 18 AWG AC input (See power supply instructions for AC input requirements) 15 x 18 AWG Magnetic Lock 64 Von Duprin 98/99 Series Schlage shown How to order * See Chexit "How to order" on page 58. *Note: RCM modules built after August 24, 2015 are built using motor driven DE5300 blocking actuators that have decreased power supply and operating requirements. The information listed in this catalog references the power supply and operating 1. See step 6l for conduit knockout requirements that are needed for the new products with motor driven blocking actuators. locations that can be used. For information on devices built previous to August 24, 2015, please contact Customer Care at Trim wires not shown on diagram, add them as needed. 2 x 18 AWG EPT2/10 RXLC Exit Device Card Reader Figure Figure 1. Riser 1. Riser Diagram, Diagram, Single Single Door Door PAGE 100

62 Electrical options & accessories 98/99 Electrical options EL Electric latch retraction The EL feature allows for the remote unlatching of exit devices. A control station operator can flip a switch to retract the latch bolt and immediately change an exit door to push-pull operation. A powerful, continuous duty solenoid retracts the latch bolt, either for momentary unlatching, or for extended periods of time. The EL feature is an alternative to manual dogging. If manual hex-key dogging is required, specify HD-EL. If cylinder dogging is required, the standard cylinder dogging is not available, but special center case dogging is available, specify SD-EL. SD-EL is not available on the 9875 or 9975 devices. EL devices are also useful with automatic door operators, and may be applied to fire-rated applications when under the control of an automatic fire alarm system. UL approved for Class II circuit applications. The EL option does not include the power transfer from door to frame, the power supply, or the control operator. Refer to EPT-2 power transfer and the PS914 power supply. The PS914 with the 9002RS option card is the minimum option card required. Other option cards available for other functions, see PS914 power supply for additional information. Solenoid specifications: Continuous duty 24 VDC Current inrush 16 Amps Current holding 0.3 Amps Solenoid resistance: -grn-yel OHMS -grn-org OHMS To order, specify: Standard use prefix EL, example EL99L. Hex Key dogging Use prefix HD-EL, example HD-EL99L. Special center case dogging Use prefix SD-EL, example SD-EL99L Minimum door opening widths: Application Surf. vert. Con. vert. Mortise Rim Min. door opening 28 1/4" 28 1/4" 28 3/4" 29 1/4" 120/240 VAC SC I1 O1 I2 O2 GND Von Duprin exit device a* b* a* b* Popular EL application Power supply PS914-2RS Electric power transfer EPT-2 or EPT-10 EPT-2 EPT-2 EL #2 EL #1 EL Wire length (feet) 1 Input #2 (Required for independent operation only). Input # EL 98/99 Rim a * All other 98/99EL device types b * Control Switch Wire gauge (AWG) 1. Wire lengths include an EPT, Door loop, electric hinge or pivot and are measured one way between the PS914/option board and the device. 2. Table is applicable to devices that have shipped after August Von Duprin 98/99 Series QEL Quiet electric latch retraction The QEL feature allows for the remote unlatching of exit devices. A control station operator can flip a switch to retract the latch bolt and immediately change an exit door to push-pull operation. Different than the popular EL, the QEL quiet operation is achieved using an electric drive motor which retracts the latch bolt either momentary unlatching or for extended periods of time. This feature is an alternative to manual dogging. If cylinder dogging is required, the standard cylinder dogging is not available, but special center case dogging is available, specify SD-QEL. SD-QEL is not available on the 9875 or 9975 devices. QEL devices are also useful with automatic door operators, and may be applied to fire-rated applications when under the control of an automatic fire alarm system. UL approved for Class II circuit applications. The QEL option does not include the power transfer from door to frame, the power supply, or the control operator. Refer to EPT-2 power transfer and the PS902 or 914 power supply. The PS902/914 with the 2RS, 4RL or 4R board is the minimum required. Other option boards available for other functions, see PS902/914 power supply for additional information. The QEL has a low in rush current, so it can be used with standard Schlage power supplies. Calculate the peak current draw of all devices in the system to determine the required amperage of the supply. Schlage PS902 Schlage PS904 Schlage PS906 up to 2 amps up to 4 amps up to 6 amps QEL Electrical load Voltage 24VDC Current 1.0 A Inrush (0.5 sec.) / 0.14 A Holding The -2RS option board is designed to control two electric latch retraction devices and provide time delay between the firing of outputs is required. The power transfer is also sold separately. To order, specify: Standard use prefix QEL, example QEL99L. Special center case dogging use prefix SD-QEL, example SD-QEL99L 120/240 VAC SC I1 O1 I2 O2 GND a* b* a* Popular application Power supply PS902-2RS Electric power transfer EPT-2 or EPT-10 EPT-2 EPT-2 QEL #2 QEL #1 Input #2 (Required for independent operation only). Input #1 b* a * Distance (one-way) Wire gauge AWG AWG AWG AWG b * Wire selection Switch wire size 1200 ft. Max. 18 gauge standard PAGE 101

63 33A/35A Series Exit devices

64 33A/35A Rim device 1439 Roller ships standard, optional strikes available 33A and 35A for all types of single and double doors with mullion, UL listed for panic exit hardware. Devices are ANSI A Grade 1. The 35A has a smooth mechanism case and the 33A has grooved case. The rim device is non-handed except when the SS (signal switch) option is used. See opposite page for available outside trim and device functions. 33A/35A fits door stiles as narrow as 1 3 /4 (44mm). Newly designed device has a one piece center case cover. 299 Strike needs to be specified for Hollow Metal Frames Finishes US3, US4, US10, US15 (35A Only) US26, US26D, US26D-AM,US28, 313 and A/35A Rim device Specifications Device lengths Device centerline from finished floor Center case dimensions Mechanism case dimensions Projection Latch bolt Fasteners & sex bolts (SNB) Electric options Mechanical options Miscellaneous options Dogging feature Strikes 3' 2' 4" to 3' (711mm to 914 mm) Door size 4' 2'10" to 4' (864 mm to 1219 mm) Door size /16" (1011 mm) /16" (1008 mm) with Mullion 8 3 /16" x 1 9 /16" x 2 13 /32" (208mm x 40mm x 62mm) 2 1 /4" x 2 1 /4" (57mm x 57mm) Pushbar Neutral 3 13 /16" (97 mm) Pushbar Depressed 3 1 /16" (78 mm) Deadlocking, 3 /4" (19mm) throw Includes 1 3 /4" (44mm) 2 1 /4" (57mm) wood & metal doors #425 SNB furnished standard for end case #325 SNB furnished standard for EO (exit only device) ALK Alarm kit CX Chexit delayed exit EL Electric latch retraction HD-EL Electric latch retraction with hex dogging QEL Quiet electric latch retraction RX Request to exit, WP-RX waterproof option LX Latchbolt monitoring LX-RX Request to exit / latchbolt monitoring RX-LC, LX-LC, LX-RX-LC Low current option for RX, LX, LX-RX SS Signal switch CON Allegion Connect AX Accessible device GBK Glass bead kit PN Pneumatic SG Safety glow SEC Security screws SNB Sex bolts Hex Dogging standard CD Cylinder dogging LD Less dogging 1439 Dull black Optional strikes QEL Quiet electric latch retraction Bolt retraction via switch Converts exit door to push-pull operation CX Chexit delayed exit Meets NFPA 101 requirements Self-contained controls, locking, alarm EL Electric latch retraction Enables remote unlatching Alternative to manual dogging E (E360L) Electric lever trim Electrified remote locking/unlocking Fail safe & fail secure options available No key override PN Pneumatic latch retraction For areas where electrical devices banned Special linkage for mechanical or pneumatic dogging AX Accessible device UL certified to meet new 5 lb. maximum operating force requirement Exceeds ANSI/ BHMA requirements ALK Alarm exit kit Unauthorized opening triggers 85-decibel horn Set in armed or disarmed mode by key RX Pushpad monitor switch Signals use of an opening SPDT switch to monitor pushpad CON Allegion Connectors Common connectors to connect various door hardware all the way to the power supply CD Cylinder dogging Replaces hex key dogging Requires standard 1 1 /4" mortise cylinder 8 Von Duprin 33A/35A Series

65 Standard trim EO DT NL NL-OP Product description No outside trim Exit only 33A-EO 35A-EO Dummy trim Pull when dogged 33A-DT 35A-DT Night latch Key retracts latchbolt 33A-NL 35A-NL Night latch Key retracts latchbolt optional pull required 33A-NL-OP 35A-NL-OP Trim description 386DT 386NL 388 Base size 7 15 /32" x 1 5 /8" 7 15 /32" x 1 5 /8" 7 1 /2" x 1 11 /16" (190x41mm) (190x41mm) (190x43mm) Grip size 8¹ ₂" x 4⁵ ₁₆" (216x110mm) 8¹ ₂" x 4⁵ ₁₆" (216x110mm) Projection 2 7 /16" (62mm) 2 7 /16" (62mm) 1" (25mm) ANSI function Cylinder type Rim Rim Handing Handed Optional trim x360l-dt x550dt x550dt x IVES " x IVES 8190 Product description Lever Key Locks and Unlocks 33A-L 35A-L Lever Blank Escutcheon Always Operable (No Cylinder) 33A-L-BE 35A-L-BE Thumbturn Key Locks and Unlocks 33A-T 35A-T Trim description 360L 360L-BE 360T 360T-BE Base size 7 1 /2" x 1 11 /16" x 7 /8" (190x43x22mm) L L-BE 7 1 /2" x 1 11 /16" x 7 /8" (190x43x22mm) 7 1 /2" x 1 11 /16" x 7 /8" (190x43x22mm) Thumbturn Always Operable (No Cylinder) 33A-T-BE 35A-T-BE 7¹ ₂" x 1¹¹ ₁₆" x ⁷ ₈" (190x43x22mm) Grip size Projection 3" (76mm) 3" (76mm) 1 13 /16" (46mm) 1 13 /16" (46mm) ANSI function 08 or 09 field selectable 11 or 12 field selectable Cylinder type 1 1 /4" Mortise 1 1 /4" Mortise Handing Handed/Reversible Handed/Reversible Optional trim E360L-BE E360T-BE T T-BE 33A/35A Rim device trim Note: 360L & 360T used on wood door require the 33A-WDA cover plate Notes Von Duprin 33A/35A Series 9

66 3347A/3547A Concealed vertical rod device Top latch 338 Top strike 3347A and 3547A for all types of single and double doors, UL listed for panic exit hardware. Devices are ANSI A Grade 1. The 3547A has a smooth mechanism case and the 3347A has grooved case. The concealed vertical rod device is non-handed except when the SS (signal switch) option is used. See opposite page for available outside trim and device functions. 385A Bottom strike 3347A/3547A fits door stiles as narrow as 2-1/8" (44 mm), wood door stiles as narrow as 4" (102mm). Newly designed device has a one piece center case cover. 3347A/3547A Concealed vertical rod device Finishes US3, US4, US10, US15 (35A Only) US26, US26D, US26D-AM,US28, 313 and 315. Specifications Device lengths Device centerline from finished floor Center case dimensions Mechanism case dimensions Projection Latch bolt Door undercut Top & bottom latch Vertical rods Fasteners & sex bolts (SNB) Electric options Miscellaneous options Dogging feature Strikes 2' 2' (610 mm) Door size 3' 2'4" to 3' (660mm to 914 mm) door size 4' 2'8" to 4' (813 mm to 1219 mm) door size /16" (1006mm) 8 13 /16" x 2 13 /32" x 1 9 /16" (208mm x 62mm x 40mm) 2 1 /4" x 2 1 /4" (57mm x 57mm) Pushbar neutral 3 13 /16" (97 mm) Pushbar depressed 3 1 /16" (78 mm) Deadlocking anti-friction top & bottom bolt 5 /8" (16mm) throw 1 /4" (7mm) 3 3 /4" x 1 1 /2" x 1" (89mm x 38mm x 25mm) Round 2 piece adjustable rods Top rod adjustable from 6'8" (2027mm) to 8'4" (2533mm) Bottom rod adjustable from 35 5 /8" (905mm) to 49 5 /8" (1260mm) Extension rod kits available for doors over 8'4" (2533mm) Includes 1 3 /4" (44mm) 2 1 /4" (57mm) wood & metal doors #425 SNB furnished standard for end case #325 SNB furnished standard for EO (exit only device) ALK Alarm kit CX Chexit delayed exit EL Electric latch retraction HD-EL Electric latch retraction with hex dogging QEL Quiet electric latch retraction RX Request to exit, WP-RX waterproof option LX Latchbolt monitoring LX-RX Request to exit / latchbolt monitoring RX-LC, LX-LC, LX-RX-LC Low current option for RX, LX, LX-RX SS Signal switch CON Allegion Connect GBK Glass bead kit PL Pullman latch PN Pneumatic HH Hurricane INS-2/INS-4 Insulclad kits 1/2" / 1/4" panels LBR Less bottom rod SG Safety glow SEC Security screws SNB Sex bolts Hex dogging standard CD Cylinder dogging LD Less dogging Top 388 Unfinished, bottom 385A Unfinished Optional strikes QEL Quiet electric latch retraction Bolt retraction via switch Converts exit door to push-pull operation E (E360L) Electric lever trim Electrified remote locking/unlocking Fail safe & fail secure options available No key override EL Electric latch retraction Enables remote unlatching Alternative to manual dogging DI Dogging Indicator Monitor dogging status without a control panel Red indicator light shows visibility to dogging from over 75 feet CD Cylinder dogging Replaces hex key dogging Requires standard 1 1 /4" mortise cylinder 283 Top strike for use with wood frames Bottom latch RX Pushpad monitor switch Signals use of an opening SPDT switch to monitor pushpad ALK Alarm exit kit Unauthorized opening triggers 85-decibel horn Set in armed or disarmed mode by key CON Allegion Connectors Common connectors to connect various door hardware all the way to the power supply PN Pneumatic latch retraction For areas where electrical devices banned Special linkage for mechanical or pneumatic dogging 16 Von Duprin 33A/35A Series

67 Standard trim EO DT NL NL-OP TL Product description Product description Exit only no outside trim 3347A-EO 3547A-EO Thumbturn-blank escutcheon always operable (no cylinder) 3347A-TL-BE 3547A-TL-BE Lever key locks and unlocks 3347A-L 3547A-L Lever blank escutcheon always operable (no cylinder) 3347A-L-BE 3547A-L-BE Thumbturn key locks and unlocks 3347A-T 3547A-T Thumbturn always operable (no cylinder) (behind C/Case) 33477A-T-BE 35477A-T-BE Trim description 376T-BE x L 360L-BE 360T 360T-BE Base size 7 1 /2" x 1 11 /16" x 7 /8" (190x43x22mm) Grip size 8 1 /2" x 4 5 /16" (216x110mm) Projection 2 7 /16" (62mm) ANSI function Dummy trim pull when dogged 3347A-DT 3547A-DT 7 1 /2" x 1 11 /16" x 7 /8" (190x43x22mm) 7 1 /2" x 1 11 /16" x 7 /8" (190x43x22mm) 7 1 /2" x 1 11 /16" x 7 /8" (190x43x22mm) 3" (76mm) 08 or 09 field selectable Night latch key retracts latchbolt 3347A-NL 3547A-NL 3" (76mm) Night latch key retracts latchbolt optional pull required 3347A-NL-OP 3547A-NL-OP 1 13 /16" (46mm) 11 or 12 field selectable Thumbturn key locks & unlocks 3347A-TL 3547A-TL Trim description 386DT 386NL T x 386 Base size 7 15 /32" x 1 5 /8" 7 15 /32" x 1 5 /8" 7 15 /32" x 1 11 /16" 7 1 /2" x 1 11 /16" x 7 /8" (190x41mm) (190x41mm) (190x43mm) (190x43mmx22mm) Grip size 8 1 /2" x 4 5 /16" (216x110mm) 8 1 /2" x 4 5 /16" (216x110mm) 7 1 /2" x 1 11 /16" x 7 /8" (190x43x22mm) 1 13 /16" (46mm) Cylinder type 1 1 /4" Mortise 1 1 /4" Mortise Handing Handed/Reversible Handed/Reversible Optional trim x E360L-BE E360T-BE 8 1 /2" x 4 5 /16" (216x110mm) Projection 2 7 /16" (62mm) 2 7 /16" (62mm) 1" (25mm) 1 13 /16" (46mm) ANSI function field selectable Cylinder type Rim Rim 1 1 /4" Mortise Handing Handed Optional trim x 360L-DT x 550DT x 550DT x IVES " x IVES 8190 x TL-BE L L-BE T T-BE 3347A/3547A Concealed vertical rod device Note: 360L & 360T used on wood door require the 33A-WDA cover plate 374T used on wood door require #10-WDA cover plate Notes Von Duprin 33A/35A Series 17

68 33A/35A Electrical options ALK Alarm kit RX Request to exit The ALK battery alarm kit is a simple yet effective way to deter unauthorized use of an opening. While the exit device is still a means of egress, the ALK kit contains an internal horn. When the touch bar is depressed, the horn sounds to provide an audible means of signaling that the opening has been violated. The alarm kit can be armed or disarmed by key. Thus allowing the exit device to be set in an armed or disarmed mode. The horn is rated at 85 decibel. The key switch uses a standard 1 1 /4" (32mm) mortise cylinder with a straight cam (Schlage Cam reference B ). The unit operates on one standard 9-volt alkaline battery. When the battery is weak, the horn will emit an intermittent low battery alert signal. The RX feature is used to signal the use of an opening. This device is equipped with one internal SPDT switch which monitors the pushpad. The device can be connected to a security console, or may be used as a single door alarm when used with a horn and power supply. A continuous current electric transfer must be used for transferring power from the frame to the door. The RX switch option should not be used to control a load, but as a signalling switch (0.5 amps. resistive maximum). The RX switch is available in a low current (LC) switch. Most commonly used in computer operated monitoring systems. Also can be powered using the PS902 power supply. See PS902 for additional information. Alarm kits are available with a choice of two switch kits, RX or LX. RX monitors the touchpad and is furnished standard. LX optional latch bolt monitoring is recommended for use with surface vertical rod exit devices. Specify ALK-LX. The ALK is available in two styles, 33A ALK, grooved cover and 35A ALK, smooth cover. The ALK includes EMERGENCY EXIT ONLY. ALARM WILL SOUND decal for application on door, or the RSS push bar trim can be used instead of the door decal,specify RSS push bar trim. The External Inhibit comes standard on Von Duprin exit devices. External Inhibit (EI) allows for the use of external switch to be used to arm, disarm and reset the alarm. Auto Reset (AR) is an option that rearms the alarm after a preset time. AR is available in three field selectable times 1¹ ₂, 3 or 4¹ ₂ minutes. When the ALK is used, standard dogging is removed. If cylinder dogging is required for 3' or 4' doors the ALK can be moved to the hinge side of the device and standard cylinder dogging can be added. To order, specify: 1. Standard Use prefix RX, example RX33AEO 2. Low Current Use prefix RX-LC, example RX-LC35AEO RX2 Double request to exit The RX2 feature uses 2 RX switches. To order, specify: 1. Standard Use prefix RX2, example RX233AEO LX Latch Bolt monitoring The LX feature is used to signal the use of an opening. This device is equipped with one internal SPDT switch which monitors the latch bolt. The device can be connected to a security console, or may be used as a single door alarm when used with a horn and power supply. A continuous current electric transfer must be used for transferring power from the frame to the door. 33A/35A Electrical options To order, specify: 1. Standard, 33A ALK 2. Cylinder Dogging, CD33A ALK Minimum door sizes Device 3' (914mm) Length 4' (1219mm) Length 33A/35A 2'9" (838mm) 3'3" (991mm) 3327A/3527A 2'8" (813mm) 3'2" (966mm) 3347A/3347A-F 3547A/3547A-F 2'8" (813mm) 3'2" (966mm) 3348A/3348A-F 3548A/3548A-F 2'8" (813mm) 3'2" (966mm) The LX switch option should not be used to control a load, but as a signalling switch (0.5 amps. resistive maximum). The LX switch is available in a low current (LC) switch. Most commonly used in computer operated monitoring systems. To order, specify: 1. Standard Use prefix LX, example LX33AEO 2. Low Current Use prefix LX-LC, example LX-LC35AEO Electrical rating for all switches: Standard 2 Amp 24VDC Low Current (LC) - below 50 24VDC Note: All switches can be either factory or field installed 37 Von Duprin 33A/35A Series 37

69 33A/35A Chexit device Electrical options & accessories CX The Chexit (with motor driven blocking actuator) * The Von Duprin Chexit device is designed for controlled egress applications. It meets both life safety and security needs, as well as the requirements of NFPA 101 for "Special Locking Arrangement" and IBC "Special Egress-Control Devices". All control inputs, auxiliary locking, local alarm and remote signaling outputs are self-contained in the Chexit assembly. Numerous configurable options allow the device to be customized for the specific code or application requirements. The standard Chexit device sounds an alarm and keeps the door secured for 15 seconds following an exit attempt with immediate release upon fire. The Chexit device includes a 6" x 20" decal for application on door. PUSH UNTIL ALARM SOUNDS. DOOR CAN BE OPENED IN 15 SECONDS Chexit typical applications Chexit single door with options The Chexit is used as an access control device. The card reader allows access. Also shown in this application is an external horn and door position switch. The auxiliary horn is used for increased volume in remote locations. Using a door position switch gives added security to the opening in case the door is not reclosed. With the Chexit disarmed, the opening functions as a normal exit device. If card readers are required on both sides of the door, the normally closed contacts of the readers should be wired in series. ** Minimum door opening sizes for CX devices Consult factory for other size requirements. Device 3' (914mm) Length 4' (1219mm) Length CX33A/35A 2'10 3 /4" (883mm) 3'4 3 /4" (1035mm) CX3327A/3327A-F/3527A/3527A-F 2'10 1 /4" (870mm) 3'4 1 /4" (1022mm) CX3347A/3347A-F/3547A/3547A-F 2'10 1 /4" (870mm) 3'4 1 /4" (1022mm) CX3348A/3348A-F/3548A/3548A-F 2'10 1 /4" (870mm) 3'4 1 /4" (1022mm) CX3349A/3349A-F/3549A/3549A-F 2'10 1 /4" (870mm) 3'4 1 /4" (1022mm) CX3350/3350WDC-F/ 3550/3550WDC-F 2'10 1 /4" (870mm) 3'4 1 /4" (1022mm) Specifications / Power supply requirements * Input voltage 24VDC Input current inrush 1.25A Input current holding 390mA Alarm relay and Secure relay contact ratings 24VDC, 1A Fire alarm, Inhibit and Door position switch inputs require normally closed dry contacts. Power supply information for CX devices with motor driven blocking actuator *. Power supply PS902 (up to 2 amps) PS904 (up to 4 amps) PS906 (up to 6 amps) PS914 (up to 4 amps) Maximum number of devices 1 Chexit device 3 Chexit devices 4 Chexit devices 4 Chexit devices When powering multiple components, verify that the amperage requirements of all components combined does not exceed the power supply output rating, see table above for output ratings. Consult Installation Instructions for proper wire gauge and wire run requirements. Exceeding the recommended devices and/or not following Installation Instructions may void your warranty. Call Customer Care at or visit the Allegion website for more information - How to order * To order, specify: 1. Prefix product description number CX. Example: CX33A-L 2. Specify option (see options on page 38). Example: CX-RCM 3. Door size other than 3' (914mm). 4. Door thickness other than 1 3 /4" (45mm). 5. Finish. *Note: Chexit devices built after August 24, 2015 are built using motor driven blocking actuators that have decreased power supply and operating requirements. The information listed in this catalog references the power supply and operating requirements that are needed for the new products with motor driven blocking actuators. For information on devices built previous to August 24, 2015, please contact Customer Care at **Note: PS902 is not to be used for double door Chexit applications. Figure 1. Riser Diagram, Single Door Von Duprin 33A/35A Series

70 33/35 Chexit, RCM and DE5300 features The Chexit, Remote Chexit Module (RCM) or DE5300 devices have several features and options available to fit your applications. See below for more information. Inputs & Outputs Fire Alarm Input This input releases the door immediately upon a fire alarm allowing immediate egress. The Internal Alarm can be silenced during a fire input via an onboard switch setting. Inhibit Input (Access Control) This optional input is provided to allow authorized egress or entry when the device is Armed using an external card reader, Key Switch, etc. It also allows remote reset of the Chexit, RCM or DE5300 in an alarmed condition. The ability to reset alarms with the inhibit input can be disabled via an onboard switch setting. Door Position Switch Input An optional Door Position Switch (DPS) can provide door position status to Chexit, RCM or DE5300 for additional security, ensuring that the door is closed, and can cause alarm when the door is left or forced open. Gang Bus The Gang bus allows a Chexit, RCM or DE5300 device to signal other Chexit, RCM or DE5300 devices when it enters the Release Delay, allowing multiple doors to release at the same time in an emergency. Up to 8 devices may be connected to the Gang Bus. Alarm Relay Contacts The Alarm Relay contacts are provided as a means to control a Remote Alarm, such as a horn or lamp, or signal an external monitor. The contacts can be configured with a jumper as Normally Open or Normally Closed, and become active upon entering an alarmed condition. Secure Relay Contacts The Secure Relay contacts are provided as a means to signal an external monitor. The contacts can be configured as Normally Open or Normally Closed with a jumper, and become active when the DPS indicates the door is closed and the Push Pad is locked. Delays Release Delay When the Push Pad is pushed and the Nuisance Delay expires, the Chexit, RCM or DE5300 enters the Release Delay with alarm. During the Release Delay, the Internal Alarm sounds, the Alarm Relay activates, and the Chexit/RCM keeps the Push Pad or DE5300 magnetic lock, locked for 15 seconds (less any time already elapsed during the Nuisance Delay). Once started, the Release Delay sequence will not stop and the devices will unlock. Nuisance Delay When a Chexit, RCM or DE5300 is located in a public area, it can be desirable to limit false releases when the Push Pad is accidently pushed. The Nuisance Delay is the brief time a Push Pad can be accidently pushed before the Release Delay sequence starts. If the Nuisance Time is set to 0 seconds the Chexit, RCM or DE5300 will enter Release Delay as soon as the Push Pad is pushed (when armed). Setting the Nuisance Time to 1, 2, or 3 seconds allows the Push Pad to be pressed for 1 to 3 seconds before the Chexit, RCM or DE5300 goes into Release Delay. If the Nuisance Audio and Nuisance Delay are both on, the Internal Alarm will pulse during the Nuisance Delay. The Alarm Relay does not activate during the Nuisance Delay. If the Push Pad is released before the Nuisance Delay expires, the Chexit, RCM or DE5300 will remain armed. Rearm Delay The Rearm Delay is the amount of time after the Key Switch or Inhibit Input is deactivated to when the device rearms. It is designed to give someone time to pass through the door before rearming occurs. The Rearm Time can be changed via the onboard switch settings from 0 and 28 seconds in 2 second increments. If the Rearm Time is set to 30 seconds and a DPS is used, if the door is opened and the Rearm Time expires, there will be no alarm. The Chexit, RCM or DE5300 will rearm after the door is closed. If the door never opens, the Chexit, RCM or DE5300 will rearm after 30 seconds. If not using a DPS, the Chexit, RCM or DE5300 will always rearm in 30 seconds. DPS Delay If the DPS detects that the door closed during the Rearm Delay, the Chexit, RCM or DE5300 ends the Rearm Delay and allows 2 seconds for the latch to clear the strike before rearming. Interface Key Switch The Key Switch provides the means to Arm or Disarm/Reset the Chexit, RCM or DE5300. Turning the Key Switch clockwise initiates the Rearm Delay, and turning the Key Switch counterclockwise Disarms/Resets the Chexit, RCM or DE5300. The Key Switch allows the key to be removed in either the Arm or the Disarm/Reset position. Status Indicator The red Status Indicator displays the status of the Chexit, RCM or DE5300. The Status Indicator flashes slow if the Chexit, RCM or DE5300 is armed, flashes fast in an alarmed mode, is off when inhibited and on solid during Rearm Delay. Internal Alarm The Internal Alarm sounds the status of the Chexit, RCM or DE5300. The Internal Alarm sounds continuously during and after a fire alarm or a Release Delay, pulses fast during the Nuisance Delay or a tamper and pulses slow during Disarmed Powerup mode. Settings Armed Powerup When set to OFF, a power disruption and power return will put the Chexit, RCM or DE5300 in a disarmed, unlocked alarm mode. Trim Fail Safe / Fail Secure (FS/FSE) The trim input power can be set to FS (Fail Safe; locked when energized, unlocked when deenergized or during power failure) or FSE (Fail Secure; unlocked when energized, locked when deenergized or during power failure). The trim must be bought or modified to physically function as FS or FSE. This on board setting only selects the trim input power. Electrical options & accessories 39 Von Duprin 33A/35A Series 39

71 33A/35A Chexit options DE5300 Delayed Egress System Electrical options & accessories RCM Remote Chexit Module is designed to provide the concept of the Chexit delayed exit system for door sizes smaller than the standard Chexit device can accommodate. The Chexit module is installed in a control box and mounted in a remote location. Features and functions of the standard Chexit exit device are available on the Remote Chexit Module. RCM Module Minimum door opening sizes for RCM devices Consult factory for other size requirements. Device 3' (914mm) Length Cylinders Cylinders are not furnished with the Chexit device and must be specified when ordering. Use 1 1 /4 mortise cylinder with compression ring K with straight cam and orient cam as shown. Schlage cylinder recommended for the device and the CD cylinder dogging option. See Schlage Pricebook for additional information. How to order * See Chexit "How to order" on page 36. 4' (1219mm) Length CX-RCM33A/35A 2'5" (737mm) 2'11" (889mm) CX-RCM3327A/3327A-F 2'4 1 /2" (724mm) 2'10 1 /2" (876mm) /3527A/3527A-F CX-RCM3347A/3347A-F 2'4 1 /2" (724mm) 2'10 1 /2" (876mm) /3547A/3547A-F CX-RCM3348A/3348A-F 2'4 1 /2" (724mm) 2'10 1 /2" (876mm) /3548A/3548A-F CX-RCM3349A/3349A-F 2'4 1 /2" (724mm) 2'10 1 /2" (876mm) /3549A/3549A-F CX3350/3350WDC-F/ 3550/3550WDC-F 2'4 1 /2" (724mm) 2'10 1 /2" (876mm) Specifications / Power supply requirements * Size 3.75" x 5.57" x 2.50" Input voltage 24VDC Input current inrush 1.25A Input current holding 390mA Alarm relay and Secure relay contact ratings 24VDC, 1A Fire alarm, Inhibit and Door position switch inputs require normally closed dry contacts. *Note: RCM modules built after August 24, 2015 are built using motor driven blocking actuators that have decreased power supply and operating requirements. The information listed in this catalog references the power supply and operating requirements that are needed for the new products with motor driven blocking actuators. For information on devices built previous to August 24, 2015, please contact Customer Care at DE5300 Delayed Egress System is designed for controlled egress applications when used in conjunction with a magnetic lock. It meets both life safety and security needs, as well as the requirements of NFPA for "Special Locking Arrangement" and IBC "Special Egress-Control Devices". All control units, auxiliary locking, local alarm and remote signaling outputs are selfcontained in the DE5300 assembly. DE5300 Module The DE5300 is commonly used on narrow stile doors where a standard or narrow stile Chexit is not practical. DE5300 Delayed Exit System uses a Chexit logic board and a Von Duprin RX-LC (low current request to exit) panic device to control a Schlage Electronics Direct Hold Magnetic Lock. The Chexit module for the DE5300 is installed in a control box and mounted in the wall adjacent to the door. Features and functions of the standard Chexit exit device are available on the DE5300. The DE5300 device includes a 6" x 20" decal for application on door. PUSH UNTIL ALARM SOUNDS. DOOR CAN BE OPENED IN 15 SECONDS Cylinders Cylinders are not furnished with the DE5300 and must be specified when ordering. Use 1 1 /4 mortise cylinder with compression ring K with straight cam and orient cam as shown. Schlage cylinder recommended for the device and the CD cylinder dogging option. See Schlage Pricebook for additional information. Specifications / Power supply requirements Size " x 5.57" x 2.50" Input voltage 24VDC Input current 1A Alarm relay and Secure relay contact ratings 24VDC, 1A Fire alarm, Inhibit and Door position switch inputs require normally closed dry contacts. How to order To order, specify: 1. DE M420/P, M450/P, or M490/P magnetic lock (order direct from Schlage Electronics). 3. RX-LC 22/33A/35A/98/99 device. 4. PS900 Series 5. EPT-2/10 To fire alarm contact 2 x 18 AWG To secure status 2 x 18 AWG 2 x 18 Remote Alarm 2 x 18 AWG Junction box 15 x 18 AWG Magnetic Lock 902, 904, 906, or 914 Power supply 2 x 18 AWG (plus power if required) 5 x 18 AWG AC input (See power supply instructions for AC input requirements) 2 x 18 AWG EPT2/10 DE See step 6l for conduit knockout locations that can be used. 2. Trim wires not shown on diagram, add them as needed. RXLC Exit Device Card Reader 40 Von Duprin 33A/35A Series Figure Figure 1. Riser 1. Riser Diagram, Diagram, Single Single Door Door

72 6200 Series Strikes for mortise or cylindrical devices Overview Features and benefits Von Duprin electric strikes are known for their reliability, durability and security. The 6200 Series strikes are designed to withstand abuse. Their heavy-duty stainless steel construction is fully UL1034 and UL10C listed and meets ANSI/BHMA Grade Series electric door strikes are designed for use with a variety of mortise or cylindrical locksets. Electrified strikes allow remote release of a locked door by activating a movable lip (keeper) using an entry/exit button or credential reader and can be a cost effective means for managing access Series strikes come standard as 24 VDC in fail secure mode. 12 VDC and AC operation can be selected, as can fail safe mode and other options that enable you to configure these strikes to fit your exact needs. Use 6200 Series electric strikes for retrofit applications or new construction. To assure the proper selection of an electric strike on new applications, lockset compatibility charts are shown on the next page. When using a lockset not listed or when retrofitting a strike to an existing application, please contact Von Duprin Technical Support for application assistance. 17 configurations available for cylindrical and mortise applications Heavy-duty stainless steel construction 24 VDC standard with 12, 16 and 28 VDC operation optional Two-piece plug connectors are furnished for ease of installation and removal during strike servicing Options include rectifier kit for VAC to VDC conversion, dual monitor switches, entry buzzer and Allegion Connect wire extension Six popular finishes available to suite with existing hardware Suitable for interior and exterior doors UL 10C 3-hour fire-rated (fail secure only) UL 1034 listed for burglary-resistant electric door strikes Meets ANSI/BHMA A156.31, Grade 1 for endurance and dynamic strength Meets ANSI/BHMA A156.31, Grade 1, 1500 lbs static strength Dynamic strength 70 ft-lbs Endurance 1,000,000 cycles PAGE 102

73 6200 Series power requirements Models Voltage Current Duty Amps Ohms All 12V DC Continuous All 16V DC Continuous All 24V DC Continuous All 28V DC Continuous Continuous duty = Energized 1 minute or more Wiring AC Mortise lockset compatibility 1, , 6211AL, 6211WF, 6212, 6213, 6214, 6215, 6221, 6222, 6223, 6224, 6224AL, 6225 and 6226 strikes Manufacturer Model number Von Duprin 7500 Adams Rite 4510, 4710 AC with Buzzer Baldwin 6000 Best 24H, 30H Corbin 9000 Falcon M2300, M2500, M2600, M3300, M3500, M3600 Precision Russwin Mortise Mortise Sargent 7700, 8100, 9000 Schlage L9000, K30, K40, K50, K60 DC Yale 7030, 7130, 8600, 8700 Mortise lockset compatibility 1, Manufacturer Model number Von Duprin 7500 Best 30H (not 45H/47H) Corbin/Russwin ML2200, 5000, 9000, CR2200 (not 2000) Falcon M100, M200, M300, M400, M500, M600 Sargent 7700, 8100 (not 7800/8200) DC with Buzzer Schlage L9000 Yale 8700 (not 8800) Cylindrical lockset compatibility 1, , 6211AL, 6211WF, 6212, 6213, 6214, 6215, 6221, 6222, 6223, 6224, 6224AL, 6225 and 6226 strikes Manufacturer Baldwin Cylindrical latchbolt projection 1 2" 3 4" (13 mm 19 mm) Best 3 8" 3 4" (10 mm 19 mm) 2 Corbin Falcon Russwin Sargent 1 2" 3 4" (13 mm 19 mm) 1 2" 3 4" (13 mm 19 mm) 1 2" 3 4" (13 mm 19 mm) 1 2" 3 4" (13 mm 19 mm) Optional DS (FSE Shown) Schlage 3 8" 3 4" (10 mm 19 mm) 2 Yale Note: 1 2" 3 4" (13 mm 19 mm) When using device not listed or when retrofitting a strike to an existing application, please contact Von Duprin Technical Support for application assistance. 1. Von Duprin cannot guarantee compatibility, as other manufacturer s designs may change without notice. 2. Signalling may not function when using 3 8 (10 mm) throw bolt. Deadlocking cannot be guaranteed with all locks. 3. When using a lockset not listed or when retrofitting a strike to an existing application, please contact Von Duprin Technical Support for assistance. Von Duprin 6200 Series PAGE 103

74 Model specifications Model number AL 6211WF 6212 Retrofits model N/A VD 3140 FA 712 FA 722 FA 732 VD 3146 Latchbolt throw 3 / 4 " 3 / 4 " 3 / 4 " 3 / 4 " 3 / 4 " Face plate length 4 7 / 8 " 4 7 / 8 " 4 7 / 8 " 4 7 / 8 " 6 3 / 8 " Backbox depth 1 3 / 4" 1 11 / 16" 1 11 / 16" 4 1 / 2 " 1 21 / 32" Lockset Mortise without deadbolt Mortise with deadbolt 1" throw Cylindrical --- Number of doors Door and frame type Single Pair Hollow metal Aluminum --- Wood Options DS or DS-LC (dual monitor switches) EB (entry buzzer - fail-secure only) 28 VDC AC rectifier kit 16 VDC solenoid Certifications UL1034 UL10C 3 hour 3 hour 3 hour 3 hour 3 hour ANSI/BHMA Meets Grade 1, 1500 lbs static strength; 70 ft lbs dynamic strength; 1,000,000 cycles endurance Application Notes Application notes: 1. For use in ANSI prep at standard height. Strike pocket inserts are provided to accommodate different manufacturers deadlocking trigger locations. 2. Designed to replace Folger Adams 732. Wood frame horizontal solenoid location differs from Folger Adams. Requires additional frame prep when retrofitting. 3. Fits modified ANSI cutout. Designed to replace Von Duprin PAGE 104 Von Duprin 6200 Series

75 Model specifications Model number 6212WF Retrofits model N/A VD 3041, 3042, 3061, 3062 FA FA FA VD 3071 VD 3072 Latchbolt throw 3 / 4 " 3 / 4 " 3 / 4 " 3 / 4 " 3/4 " 3/4 " Face plate length 6 3 / 8 " 6" 9" 9" 9" 6" Backbox depth 4 1 / 2 " 2 1 / 2 " 2" 1 5 / 8 " 2 7 / 8" 4 3 / 4 " Lockset Mortise without deadbolt Mortise with deadbolt 1" throw Cylindrical --- Number of doors Door and frame type Single --- Pair Hollow metal --- Aluminum --- Wood See note 1 below Options DS or DS-LC (dual monitor switches) EB (entry buzzer - fail-secure only) 28VDC AC rectifier kit 16VDC solenoid Certifications UL1034 UL10C 3 hour 3 hour 3 hour 3 hour 3 hour 3 hour* ANSI/BHMA Meets Grade 1, 1500 lbs static strength; 70 ft lbs dynamic strength; 1,000,000 cycles endurance Application notes * When pair door has inactive leaf. Application notes: 1. Includes wood frame for retrofit applications. 2. Deadbolt must be manually operated. 3. Open back electric strike for use on 1 3 4" (44 mm) thick double door applications " (120 mm) minimum stile required. For a concealed vertical rod and mortise device combination, specify A backbox. Von Duprin 6200 Series PAGE 105

76 Model specifications Model number AL Retrofits model FA /4 OB VD 3091 VD 3092 FA /4 FA 310-2RF FA OB FA Latchbolt throw 3/4 " 3/4 " 3/4 " 3/4 " 3/4 " 3/4 " Face plate length 9" 6" 9" 9" 9" 9" Backbox depth 2" 4 1 / 2 " 2" 1 5 / 8 " 1 5 / 8 " 1 5 / 8 " Lockset Mortise without deadbolt Mortise with deadbolt 1" throw Cylindrical Number of doors Door and frame type Single Pair Hollow metal --- Aluminum Wood Options DS or DS-LC (dual monitor switches) EB (entry buzzer - fail-secure only) 28VDC AC rectifier kit 16VDC solenoid Certifications UL1034 UL10C 3 hour* 3 hour* 3 hour* 3 hour* 3 hour* 3 hour* ANSI/BHMA Meets Grade 1, 1500 lbs static strength; 70 ft lbs dynamic strength; 1,000,000 cycles endurance Application notes * When pair door has inactive leaf. Application notes: 1. Open back electric strike for use on 1 3 4" (44 mm) thick double door applications 2. Closed back electric stirke for use on 1 3 4" (44 mm) thick double door applications " (120 mm) minimum stile required. For a concealed vertical rod and mortise device combination specify A backbox. 3. Closed back electric strike for use on 1 3 4" (44 mm) or 2 1 4" (57 mm) thick double door applications. 4. Closed back electric strike for use on 1 3 4" (44 mm) or 2 1 4" (57 mm) thick aluminum double door applications. 5. Open back electric stirke for use on 1 3 4" (44 mm) thick double door applications. 6. Closed back electric strike for use on 1 3 4" (44 mm) or 2 1 4" (57 mm) thick double door applications. PAGE 106 Von Duprin 6200 Series

77 Dimensions WF 1 1 /4" (32mm) 1 9 /16" (38mm) 1 3 /4" (44mm) 1 1 /4" (32mm) 1 15 /32" (37mm) 4 1 /2" (114mm) 4 7 /8" (124mm) 1 3 /8" (35mm) 7 /8" (22mm) 1 /2" (13mm) 3 3 /8" (86mm) 3 1 /4" (83mm) 1 /8" (3mm) 12" (305mm) 6 3 /8" (162mm) 7 /8" (22mm) 1 /2" (13mm) 2 1 /16" (52mm) 3 3 /8" (86mm) 1 /8" (3mm) Minimum Clearance 3 9 /16" (90mm) /4" (32mm) 1 11 /16" (43mm) 1 15 /32" (37mm) 2 3 /16" (56mm) 1 1 /4" (32mm) 2 1 /2" (64mm) 4 7 /8" (124mm) 7 /8" 1 1 (22mm) /4" (32mm) 1 /2" (13mm) 3 3 /8" (86mm) 2 1 /16" (52mm) 1 /8" (3mm) 12" (305mm) Minimum Clearance 6" (152mm) 1 " (25mm) 1 1 /4" (32mm) 3 7 /8" (98mm) 1 3 /8" (35mm) 1 /4" (6mm) 4 1 /2" (114mm) Minimum Clearance 6211AL /4" (32mm) 1 11 /16" (43mm) 1 15 /32" (37mm) 1 3 /8" (35mm) 2" (51mm) 1 5 /8" (41mm) 4 7 /8" (124mm) 7 /8" (22mm) 1 1 /4" (32mm) 1 /2" (13mm) 3 3 /8" (86mm) 2 1 /6" (52mm) 1 /8" (3mm) 12" (305mm) Minimum Clearance 9" (229mm) 1" (25mm) 11 /16" (17mm) 3 3 /4" (95mm) 1 5 /8" (41mm) 5 /32" (4mm) 12"(305mm) Minimum Clearance 6211WF /4" (32mm) 1 15 /32" (37mm) 1 3 /8" (35mm) (38mm) 4 1 /2" (114mm) (41mm) 4 7 /8" (124mm) 7 /8" (22mm) 3 3 /8" (86mm) 2 1 /6" (52mm) 1 /8" (3mm) 3 9 /16" (90mm) Minimum Clearance 9" (229mm) 1" (25mm) 11 /16" (17mm) 1 5 /8" (41mm) (95mm) (4mm) (305mm) /4" (32mm) 1 15 /32" (37mm) 1 11 /16" (43mm) 1 3 /8" (35mm) 1" (25mm) 3 5 /32" (80mm) 2 7 /8" (73mm) 6 3 /8" (162mm) 7 /8" (22mm) 1 /2" (13mm) 1 /2" (13mm) 3 3 /8" (86mm) 2 1 /16" (52mm) 1 /8" (3mm) 12" (305mm) Minimum Clearance 9" (229mm) 5 3 /8" (137mm) 3 3 /4" 1 5 (95mm) /8" (41mm) 3 /4" (19mm) 5 /32" (4mm) 6 1 /8" (156mm) Minimum 15 /16" Clearance (24mm) Von Duprin 6200 Series PAGE 107

78 Dimensions AL 6 " (152mm) 3 7 /8" (98mm) 1 7 /16" (37mm) 1 1 /4" (32mm) 4 1 /2" (114mm) 3 7 /8" (98mm) Minimum Clearance 9" (229mm) 1" (25mm) 1 3 /8" (35mm) 1 5 /8" (41mm) 1 1 /2" (38mm) 1 5 /8" (41mm) 3 3 /4" (95mm) 1 5 /8" (41mm) 12"(305mm) Minimum Clearance 1 3 /4" (44mm) 1 1 /4" (32mm) 11 /16" (17mm) 5 /32" (4mm) /16"(41mm) 2"(51mm) 2 1 /16"(22mm) 1 1 /2"(38mm) 9" (229mm) 1 5 /8" (41mm) 1 5 /8" (41mm) 12"(305mm) Minimum Clearance 3 3 /4" (95mm) 9" (229mm) 1 5 /8" (41mm) 1 5 /8" (41mm) 3 3 /4" (95mm) 12"(305mm) Minimum Clearance 1 3 /8" (35mm) 1 3 /8" (35mm) 5 /32"(4mm) /4" (32mm) 4 1 /2" (114mm) 1 3 /8" (35mm) 1 1 /2" (38mm) 1 5 /8" (41mm) 6" (152mm) 1" (25mm) 1 3 /4" (44mm) 3 7 /8" (98mm) 1 3 /8" (35mm) 1 /4" (6mm) 3 7 /8"(98mm) Minimum Clearance 9" (229mm) 1" (25mm) 11 /16" (17mm) 1 5 /8" (41mm) 3 3 /4" (95mm) 5 /32" (4mm) 12"(305mm) Minimum Clearance /8" (35mm) 2" (51mm) 9" (229mm) 1" (25mm) 1 5 /8" (41mm) 3 3 /4" (95mm) 1 5 /8" (41mm) 12"(305mm) Minimum Clearance 11 /16" (17mm) 5 /32" (4mm) PAGE 108 Von Duprin 6200 Series

79 Ordering information 6210-FSE-DS-24-S024-US3- EB- CON Model Power failure mode Dual switch * Voltage Rectifier kit * Finish Buzzer * Allegion Connect * * Optional Selections correspond with the numbers above 1 Model Reference specification chart to make the proper model selection 2 Power failure mode FSE Fail-secure. Requires power to be applied to unlock the strike lip. On loss of power, the strike lip is locked. Fire-rated. FS Fail-safe. Requires power to be applied to lock the strike lip. On loss of power, the strike lip is unlocked. Non-fire-rated. 3 Dual switch (optional) DS Monitors latch bolt and lock status. DS switches rated for 24 VDC at amps. DS-LC Low current option for computer monitoring. Monitors latch bolt & lock status. DS-LS switches rated for 24 VDC at.050 amp or less. 4 Voltage (VDC) 24 Low voltage DC power (standard) 12 Low voltage DC power 16 Low voltage DC power 18 Low voltage DC power 5 Rectifier kit (optional) S012 Converts 12 VAC voltage to 12 VDC to operate the solenoid S024 Converts 24 VAC voltage to 24 VDC to operate the solenoid 6 Finish US3 Plated polished brass on stainless steel US4 US10 US10B BHMA 629/US32 Plated dull brass on stainless steel Plated dull bronze on stainless steel Plated dark bronze, oil rubbed on stainless steel Stainless steel, polished BHMA 630/US32D Stainless steel, satin 7 Buzzer (optional) EB Entry Buzzer Only available if Fail-Secure (FSE) is specified. 8 Allegion Connect CON Allegion Connect Connector 6 in. wire extension harness available If AC power is required, specify rectifier kit. Allegion, the Allegion logo, Schlage, Von Duprin, the Von Duprin logo, and Falcon are trademarks of Allegion plc, its subsidiaries and/or affiliates in the United States and other countries. All other trademarks are the property of their respective owners. About Allegion Allegion (NYSE: ALLE) is a global pioneer in safety and security, with leading brands like CISA, Interflex, LCN, Schlage and Von Duprin. Focusing on security around the door and adjacent areas, Allegion produces a range of solutions for homes, businesses, schools and other institutions. Allegion is a $2 billion company, with products sold in almost 130 countries. For more, visit Allegion , Rev. 04/16 PAGE 109

80 98/99 Electrical options Power Supplies Series PS902/914 PS902 PS904 PS906 PS914 Number of connectors on power supply for the 2 amps 4 amps 6 amps 4 amps following: Distribution boards Battery back-up board Overview: The PS900 Series is a consolidated line of power supplies and accessories that offer enhanced flexibility and functionality specific to the changing needs of the access control market. The PS900 Series can be used in a variety of applications to convert high voltage AC power into the low voltage DC outputs required by most access control devices. The PS900 Series protects devices downstream by providing Class 2*, filtered and regulated power. The full line is UL294 certified. Note: PS906 can provide Class 2 rated outputs when used with 900-8P distribution board. Features: Constant output rating at both 12 VDC and 24 VDC provides superior performance ; includes field selectable jumper Polarized connectors for option boards eliminate need for racks and side connectors Flat mounting of option boards provides easier access to terminal blocks for connection of electrified devices High voltage protective cover Battery back-up board auto-selects voltage Fire alarm relay can be configured to provide either switched or un-switched outputs from a power supply PS914 designed with high in rush current for powering electrified panic devices Universal VAC input Low voltage DC, regulated and filtered Electronic power limiting foldback circuit for AC current overload protection Fused primary input AC status monitor- isolated SPDT contacts AC input and DC output LED status indicators Cover mounted AC input indication Hinged cover with lock down screws Certifications: UL 294 certified the standard for access control Class 2 rated* * Except PS906, output rating exceeds Class 2 power limits Note: One fire alarm board can be connected directly to the PS902. If a fire alarm board is desired for the PS904, PS906 or PS914 it can be connected to a distribution board. Applications: The PS900 Series of power supplies works with many electrified devices including Schlage electromagnetic locks, Schlage AD-Series hardwired locks, Schlage electrified mechanical locks, Von Duprin electrified strikes, Von Duprin exit devices, and many other brands. Accessories: The Schlage PS900 Series features seven option boards for use in a variety of applications. All Schlage PS900 Series power supplies option boards are UL 294 certified. Option boards: 900-4R: 4 relay controlled output board to power multiple devices 900-4RL: 4 relay distribution board with logic is field configurable for time delay function, auto operator, security interlock 900-8F: Provides 8 individually fuse-protected outputs, giving the flexibility to power multiple devices and provide another layer of protection 900-FA: Emergency interface relay integrates with fire alarm and is used to cut power in case of emergency 900-BB: Battery backup 900-2RS: 2 relay EL/QEL panic device control board (PS914 - required for EL) 900-BBK: Battery backup kit includes two 7A/hr batteries and provides up to four hours of backup power when cycled every 5 minutes at full load Electrical options & accessories Once power is converted to low voltage DC, the PS900 Series offers a variety of distribution options, including basic fuse protection, simple relay, and advanced logic providing complex sequencing and timing functions. * PS906 can provide Class 2 rated outputs when used with 900-8P distribution board. PAGE 110 Von Duprin 98/99 Series 67

81 Electric Power Transfer Electronic locks Fire Rated: Tested on fire door assemblies in accordance with Australian Standards, refer fire door manufacturer for specific approval details The Von Duprin electric power transfer device provides a means of transferring electrical power from a door frame to the edge of a swinging door. The units are completely concealed when the door is in the closed position, and are ideally suited for installations involving abuse or heavy traffic. The Von Duprin EPT cannot be used for: Doors less than 44mm thick 38mm offset pivots Butt hinges larger than 152mm Pocket pivots Swing clear hinges Centre hung door (centre pivot) Balanced door E 7 PAGE 111 July 2016

82 Specification guide Prefix Model VDE EPT EPT Prefix All codes are prefixed with... VDE 2. Model Select the desired model - e.g. EPT 2... VDE10077 Field Wiring EPT 2 - two 18 gauge wires EPT 10 - ten 24 gauge wires Frame Backbox Door Backbox The following allowances apply to a 44mm thick door: opening with up to 127mm butt hinges opening with up to 19mm offset pivots opening with 140mm butt hinges opening with 152mm butt hinges Field Wiring Specifications Housing 229mm x 32mm x 38mm Frame Door Electrical ratings EPT 2 Two 18 gauge wires up to 2 24VDC, with a 16 amps maximum surge EPT 10 Ten 24 gauge wires, up to1 24VDC, with a 16 amps maximum surge Door thickness 44mm minimum Warranty 1 year 95.3mm max. when installed 22mm Recommended 152.4mm below upper hinge 17mm 16mm for frame 25mm dia. x 6mm deep 213mm 230mm 197mm 6mm 6mm 16mm for door 16mm dia. through to wire channel 9mm 32mm min. 9mm July mm 41mm 41mm PAGE 112 E 8

83 Allegion Connect Cross category electrified solution for FAlcon, IVES, Schlage and Von Duprin Overview Allegion Connect is a cross-category electrified solution utilizing common interconnect components to our electrified options. Allegion Connect is a quick and easy way to connect power sources; all the way from your power supply to electrified door hardware. There is no wire cutting; reducing installation and maintenance time ultimately cutting cost. After installation, Allegion Connect continues to provide benefits throughout the lifetime of the opening by offering a comprehensive service kit. Our cross category product offering is interchangeable which allows for simple upgrades and replacements. Features and benefits Available products Von Duprin Exits 22, 33A/35A, 98/99 Series Electric strikes EPT , 6200 Series Schlage Locks ND Series - 10, 12, 80, 96 functions L Series , 9082 functions Falcon Exits 24, 25 Series IVES Locks Architectural hinges Geared hinges 112, 224 Pin/barrel hinges T Series - 851, 881 functions MA Series - 851, 881 functions 3CB1, 5BB1 Standard and heavyweight 600, 700, 715 For more visit or call Quick: common connections reducing installation time Perfect connections: these factory installed connectors ensure the right wires match up every time Protective: the connectors protect the connection points throughout the installation process and lifetime of the opening Interchangeable: all Allegion Connect products utilize the same connectors Maintenance: you no longer need to cut away wire to disconnect Allegion products, also available are service kits specifically for Allegion Connect PAGE 113

84 Allegion Connect - the perfect connection Locks, exits, hinges and accessories How to order 1. Specify CON for Connect electronic options Example: EL-99-EO-CON (99 Series Electrified Latching exit only with ConneX connectors) 2. Specify harness length; Consult door manufacturer for harness length 3. Specify Von Duprin EPT10-CON or Ives 7200 power transfer hinge Note: Must be ordered with exit devices and locks Note: You will need to purchase a separate wiring harness to go from exit device to EPT/hinge/electric strike. We recommend the use of our 6" power supply harness (connectors on one end, flying lead on the other) to tie into wiring coming out from power supply or access control system. Wiring harnesses have 8 pin and 4 pin connectors on each end, or can be ordered with the connectors on one end only. Harnesses are available in several configurations and lengths to fit your opening requirements. Options include: connector to connector, connector to pin end, connector to flying leads 2 How to order examples Von Duprin CX-99-EO-CON EPT-10-CON Schlage locks ND80PDEL-RHO-626-CON L9080EUP-03A-626-CON Falcon exits EL-25-R-L-US26D-RHR-CON Falcon locks MA-851P-24-DG-626-CON IVES 5BB-1-HW-4.5x CON-TW8 112HD-CL-83-TW8-CON TW8-CON Wire run options Note: For illustration purposes only. Consult your door manufacturer for harness length requirements. 5 Refer to power supply installation instructions for information on wiring requirements (wire gauge, distance requirements, etc.)for system. Harness lengths Harness length Connectors on both ends 6 inches CON-6 CON-6P 12 inches CON-12 CON-12P 26 inches CON-26 CON-26P 32 inches CON-32 CON-32P Connectors on one end, crimped pins on other end (recommended for doors with narrow channel) 38 inches CON-38 CON-38P 44 inches CON-44 CON-44P 50 inches CON-50 CON-50P 4 Optional 6 power supply harness with connectors on one end and flying leads on the other end for ease of connection to power supply 192 inches CON-192 CON-192P Optional power supply wire harness: Connectors on one end, stripped leads on the other end, offereing a direct connection to the power supply 6 inches CON-6W - wire extension to power supply Note: Wiring harnesses are used to connect the door hardware (lock, exit device) to the EPT/hinge, and an additional wiring harness can be used to route from the EPT/hinge to locations outside of the frame. Wiring harnesses are not to be used to connect system to power supply, refer to your power supply installation instructions for more information. We recommend the use of our optional 6 power supply harness (connectors on one end, flying leads on the other) to tie into wiring coming out from power supply or access control system. Consult door manufacturer for harness length requirements. Harness part numbers with ordering information can be located in the Schlage, Von Duprin and Falcon pricebooks. 1 Connect ready door hardware 3 Von Duprin EPT10/IVES power transfer hinge - must be ordered when using exit device or locks A service kit is available for order in the Schlage, Von Duprin and Falcon pricebooks. Included in this kit are male end plugs, female end plugs and pins to customize harnesses to your application. Contact your local Allegion Representative today at or visit allegion.com/us to learn how our Connect solution can simplify your installation and maintenance processes. About Allegion Allegion (NYSE: ALLE) creates peace of mind by pioneering safety and security. As a $2 billion provider of security solutions for homes and businesses, Allegion employs more than 8,000 people and sells products in more than 120 countries across the world. Allegion comprises more than 25 global brands, including strategic brands CISA, Interflex, LCN, Schlage and Von Duprin. For more, visit Allegion , Rev. 10/14 PAGE 114

Overview ML2000. Table of Contents

Overview ML2000. Table of Contents Overview Table of Contents Overview...2 Features...3-4 Functions...5-9 ML20900 ECL Applications...10 ML20900 ECL Features...12 ML20900 ECL Functions...13 ML20600 NAC Series Electrified Mortise Lock with

More information

Overview ML2000. Table of Contents

Overview ML2000. Table of Contents Overview Table of Contents Overview...2 Features...3-4 Functions...5-9 ML20900 ECL Applications...10 ML20900 ECL Features...12 ML20900 ECL Functions...13 ML20600 NAC Series Electrified Mortise Lock with

More information

Overview ML2000. Table of Contents

Overview ML2000. Table of Contents Overview Table of Contents Overview...2 Features...3-4 Functions...5-9 ML20900 ECL Applications...10 ML20900 ECL Features...12 ML20900 ECL Functions...13 ML20600 NAC Series Electrified Mortise Lock with

More information

Overview ML2000. Table of Contents

Overview ML2000. Table of Contents Overview Table of Contents Overview...2 Features...3-4 Functions...5-9 ML20900 ECL Applications...10 ML20900 ECL Features...12 ML20900 ECL Functions...13 ML20600 NAC Series Electrified Mortise Lock with

More information

ML2000 Series. Mortise Locksets

ML2000 Series. Mortise Locksets ML2000 Series Mortise Locksets Overview ML2000 Series Table of Contents ML2000 Series Overview...2 ML2000 Series Features...3-4 ML2000 Series Functions...5-9 Multi-Function Configuration...10-11 ML20900

More information

Quantity Keyset Cylinder Length Cam Keyway Finish 50 AA A01 CRA1 626

Quantity Keyset Cylinder Length Cam Keyway Finish 50 AA A01 CRA1 626 Mortise Cylinders How to Order Examples Access 3 Fixed Core Mortise Cylinder Ordered Separately Quantity Keyset Cylinder Length Cam Keyway Finish 50 AA1 1500 114 A01 CRA1 626 Access 3 Fixed Core Mortise

More information

CK4400 Series. Standard Duty Cylindrical Knob Locksets

CK4400 Series. Standard Duty Cylindrical Knob Locksets Series Standard Duty Cylindrical Knob Locksets Applications Applications An outstanding combination of value and performance. Ideal for quality residential and light commercial buildings, such as: Fine

More information

CL3500 Series. Heavy-Duty Cylindrical Lever Lockset

CL3500 Series. Heavy-Duty Cylindrical Lever Lockset Series Heavy-Duty Cylindrical Lever Lockset Applications Index Applications...2 Features... 3 Functions...4 Trim Designs...6 Options & Accessories...7 How to Order...9 Quick Codes...10 How to...11 Applications

More information

CL33900 Electrified Lockset

CL33900 Electrified Lockset CL33900 Electrified Lockset Applications Provides remote locking and unlocking, utilizing the proven Series Cylindrical Lockset. Ideal for door control where increased security is necessary at all times,

More information

Light/Medium-Duty Knob Locksets. CK4700 Series

Light/Medium-Duty Knob Locksets. CK4700 Series Light/Medium-Duty Knob Locksets CK4700 Series Applications Quality The CK4700 series is a Grade 2 light/medium-duty knob lockset which provides an outstanding combination of value and performance. It is

More information

Operation. Smooth. ML2000 Series Mortise Lock

Operation. Smooth. ML2000 Series Mortise Lock Smooth Operation ML2000 Series Mortise Lock The ML2000 Series is an ANSI/BHMA Grade 1 mortise lock designed to withstand the most abusive environments. Constructed of heavy-gauge steel with unique, patented

More information

CL3200 Series. Security Bolt Lever Lockset

CL3200 Series. Security Bolt Lever Lockset Series Security Bolt Lever Lockset Applications Applications A heavy-duty, high-use lockset that combines the convenience of a barrierfree lever lockset with the security of a 1" (25mm) deadbolt in a single

More information

Entry. Entry. Entry. Entry

Entry. Entry. Entry. Entry Functions x 9800/9M800 AC2 Exit Device Outside Inside Series/Function Type Function Description ED5200(A) & ED5200S(A) *9833 Without Cylinder Outside lever locked (freewheeling) except when in passage

More information

CL3800 Series. Standard-Duty Key-in-Lever Locksets

CL3800 Series. Standard-Duty Key-in-Lever Locksets Standard-Duty Key-in-Lever Locksets Applications Index Applications... 2 Features... 3 Functions... 4 Trim Designs... 5 An economical, Grade 2 standard-duty lever lockset which provides an outstanding

More information

Standard-Duty Key-In-Lever Locksets. CL3900 Series

Standard-Duty Key-In-Lever Locksets. CL3900 Series 45037 CR CL3900 8/23/01 4:16 PM Page 1 Standard-Duty Key-In-Lever Locksets CL3900 Series Applications Applications An economical, Grade 2 standard duty lever lockset which provides an outstanding combination

More information

Tubular Lock HP3000 Series Tubular Lock with Push/Pull Paddle Trim...7

Tubular Lock HP3000 Series Tubular Lock with Push/Pull Paddle Trim...7 Specialty Hardware Table of Contents Specialty Hardware Mortise Locks ML2000 and ML20900 Series with BHSS Trim...3 ML2000 and ML20900 Series with BLSS Trim...4 ML2000 and ML20900 Series with HSS Trim...5

More information

ED5470 Panic-Listed Surface Vertical Rod Exit Device ED5470B 1-1/2 Hour Fire-Listed Surface Vertical Rod Exit Device

ED5470 Panic-Listed Surface Vertical Rod Exit Device ED5470B 1-1/2 Hour Fire-Listed Surface Vertical Rod Exit Device Surface Vertical Rod Features ED5470 Panic-Listed Surface Vertical Rod Exit Device ED5470B 1-1/2 Hour Fire-Listed Surface Vertical Rod Exit Device Features Handing Device is handed but easily field reversible.

More information

Concealed Vertical Rod Features

Concealed Vertical Rod Features Concealed Vertical Rod Features ED5800 Panic-Listed Concealed Vertical Rod Exit Device ED5800A 3-Hour Fire-Listed Concealed Vertical Rod Exit Device FOR USE WiTH METAL DOORS OnLy Features Handing Device

More information

ED7000 Series. Narrow Stile Crossbar Exit Devices

ED7000 Series. Narrow Stile Crossbar Exit Devices Narrow Stile Crossbar Exit Devices Applications Narrow Stile Crossbar Exit Devices Table of Contents Applications... 2 Applications and Listings... 3 Features, Trims and Functions Rim Exit... 4 Mullions...

More information

CL3100 Series. Lever Lockset Parts Manual

CL3100 Series. Lever Lockset Parts Manual CL00 Series Lever Lockset Parts Manual Table of Contents Outside Inside Series/ Function Type ANSI No. Function Description Page Number CL0 Passage or Closet F7 Latchbolt by lever either side. Both levers

More information

Heavy-Duty Cylindrical Knob Locksets. CK4200 Series

Heavy-Duty Cylindrical Knob Locksets. CK4200 Series Heavy-Duty Cylindrical Knob Locksets CK4200 Series Introduction Applications The highest quality materials and precision manufacturing ensure strength, durability and quiet operation. Ideal for demanding,

More information

W Series Cylindrical Lever. W Series cylindrical lever lock

W Series Cylindrical Lever. W Series cylindrical lever lock 38 W Series cylindrical lever lock Arrow W Series Grade 1 heavy duty levers offer an economically pleasing solution for ADA compliance. They re offered in a complete range of functions and finishes and

More information

CL3300 Series. Extra Heavy-Duty Cylindrical Lever Locksets

CL3300 Series. Extra Heavy-Duty Cylindrical Lever Locksets Series Extra Heavy-Duty Cylindrical Lever Locksets Overview Table of Contents Overview...2 Features...3 Functions...5 Electrified Lockset...8 Trim Designs...11 Options and Accessories...12 How to Order...15

More information

Overhead door holders/ stops

Overhead door holders/ stops Overhead door holders/ stops Quality hardware for superior door control Known throughout the industry as the overhead door holder specialist, Glynn-Johnson has made its name with state-of-the-art manufacturing

More information

Headline. Overhead Door Holders/Stops

Headline. Overhead Door Holders/Stops Headline Overhead Door Holders/Stops Quality hardware for superior door control 2 Glynn-Johnson has been providing the highest quality door control hardware for 75 years. Known in the industry as the overhead

More information

FE6800. Fortified Three-Point Latching System. Storm-Resistant Design Helps Save Lives

FE6800. Fortified Three-Point Latching System. Storm-Resistant Design Helps Save Lives FE6800 Fortified Three-Point Latching System Storm-Resistant Design Helps Save Lives For over 160 years, Corbin Russwin has been integrating life-safety with security, providing total door opening solutions.

More information

Z and DH Class Keyways Key Systems D12 59AB H41 H12 H34 H56 H78

Z and DH Class Keyways Key Systems D12 59AB H41 H12 H34 H56 H78 Keyways Z and DH Class Keyways Key Systems D Series (Russwin ) 4 keyway multiplex system. Available 5-, 6- and 7-pin. DH Class bitting. Reverse of L Series. All-Section Key D12 D41 D34 Cylinder Keyway

More information

FE6800. Fortified Multi-Point Latching System. Storm-Resistant Design Helps Save Lives

FE6800. Fortified Multi-Point Latching System. Storm-Resistant Design Helps Save Lives FE6800 Fortified Multi-Point Latching System Storm-Resistant Design Helps Save Lives Applications Index Applications............ 2 Features............... 3-4 Trim Designs............. 5-6 Functions, Options

More information

4700LN Series ANSI/BHMA Grade 1 Certified Cylindrical Lever Locks. An ASSA ABLOY Group brand

4700LN Series ANSI/BHMA Grade 1 Certified Cylindrical Lever Locks. An ASSA ABLOY Group brand 4700LN Series ANSI/BHMA Grade 1 Certified Cylindrical Lever Locks An ASSA ABLOY Group brand Table of Contents contents Features...3 Finishes & How To Order...4 Lever Trim...5 Functions... 6-8 Electrified

More information

Specifications & Certifications

Specifications & Certifications Specifications & Certifications Certification Compliance ANSI/BHMA Certified to ANSI/BHMA A156.13 Series 1000 Operational Grade 1 and Security Grade 1 with all standard trims. ANSI/ASTM F476-84 Grade 40

More information

Specifications & Certifications

Specifications & Certifications Specifications & Certifications Certification Compliance ANSI/BHMA Certified to ANSI/BHMA A156.13 Series 1000 Operational Grade 1 and Security Grade 1 with all standard trims. ANSI/ASTM F476-84 Grade 40

More information

ED8000 Series. Pushpad Exit Devices

ED8000 Series. Pushpad Exit Devices Series Pushpad Exit Devices Introduction Table of Contents Introduction...2 Applications and Listings... 3 Rim Exit Features...4 Surface Vertical Rod Exit Features...6 Rim/Vertical Rod Trims and Functions...8

More information

TL3700 Series. Tubular Lock

TL3700 Series. Tubular Lock Series Tubular Lock Introduction Table of Contents Introduction... 2 Functions... 3 Muséo Trim Designs... 4 Roses... 8 Finishes... 9 How to Order/Quick Codes... 9 Architectural Specifications... 11 Series

More information

Specifications & Certifications

Specifications & Certifications Specifications & Certifications Certification Compliance ANSI/BHMA Certified to ANSI/BHMA A156.13 Series 1000 Operational Grade 1 and Security Grade 1 with all standard trims. ANSI/ASTM F476-84 Grade 40

More information

Specifications & Certifications

Specifications & Certifications Specifications & Certifications Certification Compliance ANSI/BHMA Certified to ANSI/BHMA A156.13 Series 1000 Operational Grade 1 and Security Grade 1 with all standard trims. ANSI/ASTM F476-84 Grade 40

More information

Table of Contents 20 Series Exit Device

Table of Contents 20 Series Exit Device 20 Series Exit Device Copyright 2003, 2007, 2009-2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Table of Contents Features, Applications and UL Fire Door Ratings...

More information

Table of Contents Auxiliary Locks

Table of Contents Auxiliary Locks Copyright 2003, 2004, 2007-2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Table of Contents SSL1 Spring Latch For Security SideLight Applications...1 8200 Series

More information

8800 series grade 1 mortise locks

8800 series grade 1 mortise locks never compromise The value of any product is equal to the quality of the labor and materials put into making it. And the Yale 8800 series mortise lock is a perfect example that true quality doesn t just

More information

7 LINE CYLINDRICAL LEVER LOCK

7 LINE CYLINDRICAL LEVER LOCK 7 LINE CYLINDRICAL LEVER LOCK Specifications Table of Contents Lever Designs, Features, Benefits & Applications........................... 1 Functions..........................................................

More information

ED3000 Series. Crossbar Exit Devices

ED3000 Series. Crossbar Exit Devices Crossbar Exit Devices Introduction Table of Contents Applications and Listings... 3 Functions... 4 Rim Exit Features... 5 Surface Vertical Rod Exit Features... 7 Mortise Exit Features... 9 Trims and Functions...

More information

Simplex. Cylindrical Knob Series. Grade 1 Extra Heavy Duty Cylindrical Knob

Simplex. Cylindrical Knob Series. Grade 1 Extra Heavy Duty Cylindrical Knob Cylindrical Knob Series Grade 1 Extra Heavy Duty Cylindrical Knob SPXCK100 F82 Entry/Office Lock Push Button locking. Pushing button in inside knob locks outside lever until unlocked with key or turning

More information

Grade 1 Heavy-Duty Cylindrical Locksets DORMA CL800 CK800

Grade 1 Heavy-Duty Cylindrical Locksets DORMA CL800 CK800 Grade 1 Heavy-Duty Cylindrical Locksets DORMA CL800 CK800 CL800/CK800 Series Table of Contents CL800/CK800 Grade 1 Cylindrical Locksets Features...................................... 3 Technical Details

More information

08710/ING BuyLine 7155

08710/ING BuyLine 7155 08710/ING BuyLine 7155 LOCKNETICS ON BOARD LOCKNETICS RECOGNITION SYSTEMS VON DUPRIN GLYNN-JOHNSON IVES LCN SCHLAGE DOR-O-MATIC STEELCRAFT 80 USA 1.877.613.8766 Canada 1.905.278.6128 www.glynn-johnson.com

More information

Standard Lever Designs

Standard Lever Designs Standard Lever Designs 3-7/8" 96mm 4-3/4" 121 mm 01 64mm 02 2-15/16" 75 mm 1/2" 13mm 4-5/8" 117mm 4-5/8" 117mm 06 2-3/4" 73mm 07 3-5/8" 92mm 4-7/8" 124 mm 4-7/8" 124 mm 18 2-5/8" 67 mm Accent (ACC) Material:

More information

ED5000 Series. Pushpad Exit Devices

ED5000 Series. Pushpad Exit Devices Pushpad Exit Devices Overview Table of Contents Overview... 2 Product Series Features... 3 Applications and Listings... 4 SecureBolt Features... 6 Rim Features... 8 Surface Vertical Rod Features... 10

More information

8800 series grade 1 mortise locks

8800 series grade 1 mortise locks never compromise The value of any product is equal to the quality of the labor and materials put into making it. And the Yale 8800 series mortise lock is a perfect example that true quality doesn t just

More information

20 Series. Exit Device

20 Series. Exit Device 20 Series Exit Device Copyright 2003, 2007, 2009, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Table of Contents Table Of Contents Page Features, Applications and UL

More information

FEATURES & SPECIFICATIONS. 100% internal parts quality inspection provides security, reliability and durability

FEATURES & SPECIFICATIONS. 100% internal parts quality inspection provides security, reliability and durability For Doors... 1 ¼ Backset... 2 ¾ Lockcase... FEATURES & SPECIFICATIONS Heavy gauge zinc chromate steel Front... Heavy gauge steel x 1 ¼ x 3 / 32. Accommodates flat doors and doors beveled ⅛ in Armored Front...

More information

CL3300 Series. Extra Heavy-Duty Cylindrical Lever Locksets

CL3300 Series. Extra Heavy-Duty Cylindrical Lever Locksets Extra Heavy-Duty Cylindrical Lever Locksets Overview Table of Contents Overview...2 Features...3 Functions...5 Electrified Lockset...8 Trim Designs...11 Options and Accessories...12 How to Order...15 Quick

More information

268, 269 & 278. Concealed Door Closers

268, 269 & 278. Concealed Door Closers 268, 269 & 278 Concealed Door Closers Copyright 2004-2018, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Table of Contents General Information....3 268 Features and Benefits...4

More information

MODELS TRUE WOOD DOOR OPERATIONAL HARDWARE EXIT DEVICE MODELS LEVER X LEVER MODELS DOORS WITH FLUSHBOLTS:

MODELS TRUE WOOD DOOR OPERATIONAL HARDWARE EXIT DEVICE MODELS LEVER X LEVER MODELS DOORS WITH FLUSHBOLTS: MODELS EXIT DEVICE MODELS Concealed Less Bottom Rod Type D3976 Inset Exit Device Concealed Top Latch Only Rated Doors (Paired) LEVER X LEVER MODELS D3944 Classroom Function D3945 Passage Function D3946

More information

An ASSA ABLOY Group brand Series. Flatbar Exit Devices

An ASSA ABLOY Group brand Series. Flatbar Exit Devices An ASSA ABLOY Group brand 1800 Series Flatbar Exit Devices introduction Yale 1800 series exit devices are the ideal choice for economy commercial applications where consistent quality, ease of use and

More information

Table Of Contents. 30 Series Exit Device. On The Cover

Table Of Contents. 30 Series Exit Device. On The Cover 30 Series Exit Device Copyright 1999, 2001, 2004, 2008, 2009, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Table Of Contents Page Features, Applications and UL Fire

More information

Overhead Door Holders/Stops

Overhead Door Holders/Stops Overhead Door Holders/Stops 08 71 00/ING BuyLine 7155 STEELCRAFT SINGLE ACTING DOORS, INTERIOR/EXTERIOR APPLICATIONS, REVERSIBLE, NON-HANDED 450 Series Surface-mounted holders and stops offer the widest

More information

MA Series. Mortise Lockset Functions. MA101 FO1 Passage Latchset Latchbolt by knobs/levers at all times.

MA Series. Mortise Lockset Functions. MA101 FO1 Passage Latchset Latchbolt by knobs/levers at all times. MA Series Mortise Lockset Functions ANSI MA101 FO1 Passage Latchset Latchbolt by knobs/levers at all times. MA301 F02 Privacy Lock Latchbolt by knobs/levers, deadbolt by turn inside or emergency key outside.

More information

Olympian 100, 200, 300 Series

Olympian 100, 200, 300 Series OLYMPIAN 100, 200, 300 SERIES : EXIT DEVICES Olympian 100, 200, 300 Series Exit Devices Strength by design. Simply PRECISION TABLE OF CONTENTS Exit Devices & Trims Rim Devices...4, 5 Surface Vertical Rod

More information

Lock Functions Single Cylinder Deadbolt Functions

Lock Functions Single Cylinder Deadbolt Functions Lock Functions Single Cylinder Deadbolt Functions L9453 F20 LV9453 Entrance Lock Latchbolt retracted by knob/lever from either side unless outside is locked by 20º rotation of thumbturn. Deadbolt thrown

More information

MB1 Series ANSI Grade 1 Extra Heavy Duty Lever Locks

MB1 Series ANSI Grade 1 Extra Heavy Duty Lever Locks MB1 Series ANSI Grade 1 Extra Heavy Duty Lever Locks FEATURES: Heavy duty chassis with various lever styles available. Strong cast and machined stainless steel hubs, mounted with heavy duty return springs.

More information

Corbin Russwin. Latches, cylinders, interchangeable CORE & spindle. Latches. Lockset Cylinders. Rim Cylinders. Interchangeable Core.

Corbin Russwin. Latches, cylinders, interchangeable CORE & spindle. Latches. Lockset Cylinders. Rim Cylinders. Interchangeable Core. Latches Corbin Russwin Latches, cylinders, interchangeable CORE & spindle Mfg # Series Backset EZ # 486F90 626 4200 2-3/4 035270 Lockset Cylinders Mfg # Series Keyway EZ # 2000 052 59A1 626 4200, 5200

More information

E-Plex 5700 Series E-PLEX

E-Plex 5700 Series E-PLEX PIN/PROX or Dual Credential Electronic Pushbutton Lock 3,000 Access Codes 30,000 Audit Events Access Schedules ANSI/BHMA Grade-1 Certified Features Access Control: No Wires: Locking Device Options: Number

More information

Full-featured operator with slim profile for moderate to high traffic applications LOW ENERGY OPERATOR CATALOG

Full-featured operator with slim profile for moderate to high traffic applications LOW ENERGY OPERATOR CATALOG Full-featured operator with slim profile for moderate to high traffic applications 6300 S E R I E S LOW ENERGY OPERATOR CATALOG INTRODUCTION The Norton 6300 Series Low Energy Operator offers a broad set

More information

422 Series. Cam Action Door Closer

422 Series. Cam Action Door Closer Cam Action Door Closer Copyright SARGENT Manufacturing Company 2005-2018. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is

More information

OLYMPIAN 100, 200, 300 SERIES PRECISION HARDWARE

OLYMPIAN 100, 200, 300 SERIES PRECISION HARDWARE OLYMPIAN 100, 200, 300 SERIES PRECISION HARDWARE GENERAL INFORMATION TABLE OF CONTENTS EXIT DEVICES & TRIMS Page Rim Devices...4, 5 Surface Vertical Rod Devices...6, 7 Mortise Devices...8, 9 MULLIONS Fire

More information

W Series. Features. comparison chart. Lock type. Glossary and finish chart. MA Series. RU Series

W Series. Features. comparison chart. Lock type. Glossary and finish chart. MA Series. RU Series Lock type finish chart MA W Grade 2, medium-duty cylindrical lever and knob locks RU T Whether your application is government/military, retail, industrial or multi-family, there s a W lock that fits perfectly.

More information

3800 Series

3800 Series 3800 Series Hager 3800 Series mortise lock provides maximum security and durability for the harshest environments. With field reversible handing, ease of installation, and both escutcheon and sectional

More information

Grade 2 Cylindrical Locksets DORMA CL700 CK700

Grade 2 Cylindrical Locksets DORMA CL700 CK700 Grade 2 Cylindrical Locksets DORMA CL700 CK700 Table of Contents CL700/CK700 Grade 2 Cylindrical Locksets Features...................................... 3 Technical Details and Specifications..................

More information

E-Plex 5700 Series E-PLEX

E-Plex 5700 Series E-PLEX PIN/PROX or Dual Credential Electronic Pushbutton Lock 3,000 Access Codes 30,000 Audit Events Access Schedules ANSI/BHMA Grade-1 Certified Features Access Control: No Wires: Locking Device Options: Number

More information

K Series. Grade 1 cylindrical lever locks

K Series. Grade 1 cylindrical lever locks K Series Grade 1 cylindrical lever locks Falcon K Series 4 Overview 5 Features and specifications 6 Designs and finishes 7 Functions 8 Cylinders 9 Competitive keyways 10 Options and accessories 11 Competitive

More information

Cylinders and Keys Cylindrical Locks Mortise Locks Exit Devices Door Closers

Cylinders and Keys Cylindrical Locks Mortise Locks Exit Devices Door Closers Architectural Hardware Product Guide Condensed Catalog Cylinders and Keys Cylinders and Keys Cylindrical Locks Cylindrical Locks Mortise Locks Mortise Locks Exit Devices Exit Devices Door Closers Door

More information

Dor-O-Matic Exit Devices

Dor-O-Matic Exit Devices Dor-O-Matic Exit Devices T H E F A L C O N D I F F E R E N C E S A F E T Y, S E C U R I T Y A N D U N C O M P R O M I S I N G V A L U E At Falcon, we know that every product you sell not only has to meet

More information

DC3000 Series. Door Closers

DC3000 Series. Door Closers Door Closers Table of Contents Applications 2 Features 3 & 4 Mountings 5 & 6 Door Closer Arms 7 & 8 Mounting Brackets 9 Brackets and Covers 10 Size and Handing 11 How to Order 12 Quick Codes 13 Helpful

More information

PUSH BAR EXIT DEVICES CROSS BAR EXIT DEVICES NARROW STILE EXIT DEVICES FEATURING LCWD STRIKES... 20

PUSH BAR EXIT DEVICES CROSS BAR EXIT DEVICES NARROW STILE EXIT DEVICES FEATURING LCWD STRIKES... 20 Exit Devices Section TABLE OF CONTENTS EXIT DEVICES PUSH BAR EXIT DEVICES N1500 Heavy Duty Rim Exit Device N1550 Rim Exit Device... 6 N1650 Fire Rated Heavy Duty Exit Device N1700(F) Vertical Rod Heavy

More information

Auxiliary Locks. Deadlocks and Deadbolts. Falcon Monarch Dor-O-Matic

Auxiliary Locks. Deadlocks and Deadbolts. Falcon Monarch Dor-O-Matic Auxiliary Locks Deadlocks and Deadbolts Falcon Monarch Dor-O-Matic T H E F A L C O N D I F F E R E N C E F A L C O N A U X I L I A R Y L O C K S S A F E T Y, S E C U R I T Y A N D U N C O M P R O M I S

More information

6200 Series. Strikes for mortise or cylindrical devices. Features and benefits. Overview

6200 Series. Strikes for mortise or cylindrical devices. Features and benefits. Overview 6200 Series Strikes for mortise or cylindrical devices Overview Features and benefits Von Duprin electric strikes are known for their reliability, durability and security. The 6200 Series strikes are designed

More information

corbinrusswinvineyard.com

corbinrusswinvineyard.com table of contents levers 2 finishes, roses & escutcheons 6 mortise locksets 7 exit devices 8 access control devices 9 master key systems 9 distinctively styled lever trims VINEYARD The Vineyard Collection

More information

3400 Series

3400 Series 3400 Series Hager 3400 Series Grade 1 lock is designed and engineered to withstand the most abusive environments. We ve categorized it extra heavy duty and you can rest assured that it has been tested

More information

5300LN Series. ANSI/BHMA Grade 2 Certified Cylindrical Lever Locks

5300LN Series. ANSI/BHMA Grade 2 Certified Cylindrical Lever Locks 5300LN Series ANSI/BHMA Grade 2 Certified Cylindrical Lever Locks Table of Contents contents Benefits & Features... 3 How to Order... 4 Finishes... 5 Lever Trim... 6 Functions... 7-9 Electrified Options...

More information

COMMERCIAL DOOR HARDWARE PRODUCT CATALOG HOME DEPOT EXCLUSIVE SPECIAL ORDER PROGRAM FOR MORE INFORMATION

COMMERCIAL DOOR HARDWARE PRODUCT CATALOG HOME DEPOT EXCLUSIVE SPECIAL ORDER PROGRAM FOR MORE INFORMATION HOME DEPOT EXCLUSIVE SPECIAL ORDER PROGRAM COMMERCIAL DOOR HARDWARE PRODUCT CATALOG FOR MORE INFORMATION Find Universal Hardware in QuoteCenter Downloadable version of this catalog can be found at UniversalHardware.com

More information

DC5000 Series. Cam Action Door Closer

DC5000 Series. Cam Action Door Closer Series Cam Action Door Closer Introduction Table of Contents Introduction...2 Features... 3 Mountings... 4 Accessories... 5 How to Order... 6 Quick Codes... 6 Helpful Terms... 7 Specifications... 8 Applications

More information

Grade 2 Tubular Locksets DORMA CL600 CK600

Grade 2 Tubular Locksets DORMA CL600 CK600 Grade 2 Tubular Locksets DORMA CL600 CK600 Table of Contents Features DORMA s CL600 and CK600 Series Grade 2 tubular locksets provide the security, aesthetics, and dependability required for many applications.

More information

ADAMS RITE. ADAMS RITE MANUFACTURING COMPANY Sliding Hardware/Exit Devices Series Turns

ADAMS RITE. ADAMS RITE MANUFACTURING COMPANY Sliding Hardware/Exit Devices Series Turns Sliding Hardware/ 1000 Series Turns Series 1000 turns are designed to operate Adams Rite MS 1847 deadlocks and latches. 1000-11 and 1000-21 have a rectangular escutcheon for mounting directly on the door.

More information

Design Guidelines and Standards Manual University of Cincinnati

Design Guidelines and Standards Manual University of Cincinnati SECTION 08710D - A. SPECIFICATIONS FORMAT 1. It is preferred that this section include all items of door hardware. Window hardware and operators should be specified in the window section. This approach

More information

351 Series Door Closers Models: Finishes: BHMA BHMA Description

351 Series Door Closers Models: Finishes: BHMA BHMA Description Door Closers Adams Rite provides Surface Applied and Pocket Closers from Sargent for controlling the closing of The RITE Door. 351 Series The 351 Powerglide line of surface door closers has been engineered

More information

S200-SERIES. Interconnected Entrance Locks

S200-SERIES. Interconnected Entrance Locks Interconnected Entrance Locks Application Multi-family dwellings, hotel/motel, office and light duty commercial use. Performance Features Simultaneous retraction of deadbolt and latch for single-motion

More information

MA Series. Mortise Lockset Functions. MA101 FO1 Passage Latchset Latchbolt by knobs/levers at all times.

MA Series. Mortise Lockset Functions. MA101 FO1 Passage Latchset Latchbolt by knobs/levers at all times. MA Series Mortise Lockset Functions ANSI MA101 FO1 Passage Latchset Latchbolt by knobs/levers at all times. MA301 F02 Privacy Lock Latchbolt by knobs/levers, deadbolt by turn inside or emergency key outside.

More information

Hardware Suppliers of America, Inc.

Hardware Suppliers of America, Inc. Hardware Suppliers of America, Inc. HSI Inventory Listing FEBRUARY 2008 Inventoried Simplex es 03 Bright Brass 04 Satin Brass 05 Antique Brass 19 Black Paint 026 Bright Chromium 26D Satin Chrome 55 Duranodic

More information

2010 Product Line Catalog

2010 Product Line Catalog 2010 Product Line Catalog Electronic Access Control Locksets Now Part of 1 Electronic access control locksets With thousands of units in operation worldwide, IEI locksets are recognized for the highest

More information

Table of Contents 30 Series Exit Device

Table of Contents 30 Series Exit Device 30 Series Exit Device Table of Contents Features, Applications and UL Fire Door Ratings... 1 3727/ NB3727 Vertical Rod Type Exit Device... 2 3828 Rim Type Exit Device...3 30 Series Trims....4 Alternate

More information

CAL-ROYAL & F2200 Rim Type Panic And Fire Exit Devices 2260 & F2260 Vertical Rod Panic And Fire Exit Devices ANSI A156.

CAL-ROYAL & F2200 Rim Type Panic And Fire Exit Devices 2260 & F2260 Vertical Rod Panic And Fire Exit Devices ANSI A156. CAL-ROYAL P R O D U C T S, I N C. 3 HOUR FIRE RATED 2200 & F2200 Rim Type Panic And Fire Exit Devices 2260 & F2260 Vertical Rod Panic And Fire Exit Devices ANSI A156.3, Grade 1 Lifetime Warranty BHMA CERTIFIED

More information

T H E F A L C O N D I F F E R E N C E

T H E F A L C O N D I F F E R E N C E T H E F A L C O N D I F F E R E N C E S E C U R I T Y A N D U N C O M P R O M I S I N G V A L U E At Falcon, we know that every product you spec not only has to meet local building codes, but also your

More information

CL3300 Series. Cylindrical Lockset Parts Manual

CL3300 Series. Cylindrical Lockset Parts Manual CL3300 Series Cylindrical Lockset Parts Manual Table of Contents Mechanical Drawing...3 Chassis & Buttons...4 Spring Housing Assemblies...5 Roses/Liners and Misc...6 Latches...7 Strikes...8 Standard Levers

More information

Optional Latchbolts /8" (60 mm) Square or Round Corner, Dead Latch /4" (70 mm) Square or Round Corner, Dead Latch - Standard

Optional Latchbolts /8 (60 mm) Square or Round Corner, Dead Latch /4 (70 mm) Square or Round Corner, Dead Latch - Standard Cylindrical Grade 1 Extra Heavy Duty Commercial, Industrial, Institutional 3400 Series Lifetime warranty No exposed mounting screws Non-handed Standard and interchangeable cores available Optional Latchbolts

More information

Small Format Interchangeable Core (SFIC) Cylinders

Small Format Interchangeable Core (SFIC) Cylinders Small Format Interchangeable Core (SFIC) Cylinders The L-Series lockset can be ordered to accept small format interchangeable cores (SFIC) compatible with manufacturers such as Falcon, Arrow and Best;

More information

GRADE 1 ELECTRIFIED CYLINDRICAL & UNIT LOCKS

GRADE 1 ELECTRIFIED CYLINDRICAL & UNIT LOCKS GRADE ELECTRIFIED CYLINDRICAL & UNIT LOCKS LAK Function: Specifications: Features: Locked on the outside only. The 00mA @ VDC Vandal resistant clutch lever release inside lever is always unlocked for 9/6

More information

Cylindrical Lever Locks

Cylindrical Lever Locks 7 Line Cylindrical Lever Locks Copyright 2007-2018, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Specifications Table of Contents Windstorm Certifications... 3 Features,

More information

Auxiliary Locks Cabinet Locks, Deadlocks, Padlocks

Auxiliary Locks Cabinet Locks, Deadlocks, Padlocks Auxiliary Locks Cabinet Locks, Deadlocks, Padlocks Table of Contents contents Yale Commercial Solutions...3 Finishes...4 How to Order...5 D Series Cylindrical Deadbolts...6-10 Mortise Deadlocks...11-12

More information

Grade 2 Tubular Locksets DORMA CL600 CK600

Grade 2 Tubular Locksets DORMA CL600 CK600 Grade 2 Tubular Locksets DORMA CL600 CK600 Table of Contents Features DORMA s CL600 and CK600 Series Grade 2 tubular locksets provide the security, aesthetics, and dependability required for many applications.

More information

X Series. Features. comparison chart. Lock type. Glossary and finish chart. MA Series. RU Series

X Series. Features. comparison chart. Lock type. Glossary and finish chart. MA Series. RU Series Lock type finish chart MA X Grade 1, heavy-duty cylindrical knob locks RU T When you need a tough, reliable lock that can also withstand the corrosive conditions of a marine environment you need a Falcon

More information

M-Series Service Manual

M-Series Service Manual M-Series Service Manual Table of Contents Introduction... 1-2 Functions... 3-5 Replacement Parts for Early LM Series Lever Trim... 6 Trim Assemblies... 7-11 Falcon LM Series Mortise Trim... 7 Falcon L-900

More information

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys...

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys... TABLE OF CONTENTS A Adjustable Angle Bracket (2941/2942)... 6 Angle Brackets (2950 Series)... 9 Armature Mounting Plates (2950 Series)...7-8 C Coordinator Mounting Bracket (2950 Series)... 8 Concealed

More information