JPS VARIABLE SPEED PUMPS INSTALLATION/PROGRAMMING/ AFFINITY LAW

Size: px
Start display at page:

Download "JPS VARIABLE SPEED PUMPS INSTALLATION/PROGRAMMING/ AFFINITY LAW"

Transcription

1 JPS VARIABLE SPEED PUMPS INSTALLATION/PROGRAMMING/ AFFINITY LAW

2 Zodiac Pool Systems, Inc Regional Extension Zodiac Academy Instructor: Sales person: Phone: Sales person: Phone: Sales person: Phone: Sales person: Phone: Service Manager: Phone: Service Manager: Phone: 2

3 IMPORTANT SAFETY INSTRUCTIONS The information contained in this technical guide is intended for Zodiac trained service personnel only. Electrical installation and repairs should only be performed by a certified electrician or Zodiac trained professional. and must comply with all national electric codes (NEC, Canadian, etc.). state and local law, ordinances, codes and regulations. If you have not received training, do not attempt any of the electrical repairs presented in this document. Contact Zodiac Pool Systems, Inc. at for assistance. Read and follow all instructions carefully. When servicing equipment, basic safety precautions should always be followed including those listed below. TO REDUCE THE RISK OF ELECTRICAL SHOCK: Disconnect main power to pool equipment area prior to any service or repairs. Keep all electrical equipment at least 10 feet (3m) from inside wall of pool or spa. Connect equipment only to a receptacle (cord models) or circuit (hardwired) protected by a ground fault circuit interrupter (GFCI). Use only copper conductors and supply wires suitable for the specific device. Replace damaged power cord(s) immediately and use only identical replacement parts. Do not bury power cord(s). Position cord(s) to minimize abuse from lawn mowers, hedge trimmers and other equipment. Do not install or service equipment if precipitation is present or imminent. TO REDUCE EQUIPMENT WATER PRESSURE HAZARD: Always turn pump off to release pressure prior to removing or installing in-line equipment. To avoid equipment damage, do not exceed water pressure (psi) specifications for the device. To reduce the risk of injury, do not permit children to operate, handle or play on equipment.

4 2HP Variable Speed Pump 2 Inch Union or Internal Threads High Profile Lid Handles Ergonomic Handles 10:00AM PUMP IS PRESS RESET OR MENU Tool Free Drain Plugs For Easy Winterization High Efficiency, Permanent Magnet, TEFC, Variable Speed Motor Adjustable Base Options Available

5 2.0 HP Variable Speed Pump 40% Larger Basket Reduces Maintenance & Increases Efficiency Ergonomic Handles Jandy RS485 2 x 2.5 Unions No Nipples Required Auxiliary Circuit 2.7 Total Horsepower Premium Wet End with Installer & User Friendly Features Tool Free Drain Plugs For Easy Winterization High Efficiency, Permanent Magnet, TEFC, Variable Speed Motor Large Smooth Trap Basket High Profile Lid Handles Variable Speed Pump (1.5 HP & 2.0 HP, and SVRS options available) Ergonomic Handles High Efficiency, Permanent Magnet, TEFC, Variable Speed Motor 2-3 Inch Unions Tool Free Drain Plugs For Easy Winterization Automation Options

6 FHP JEP-R VSFHP165JEP VSFHP270JEP AUTOMATION VSFHP165AUT VSFHP270AUT PHP VSPHP270JEP VSPHP270AUT SHP N/A VSSHP220AUT VSSHP270AUT SVRS JEP2.0SVRS JEP2.0SVRS NOTE: THE SVRS PUMP IS COMPANTABLE WITH ALL CONTROLLERS VS PLATFORM TOTAL HP INTERFACE FHP PHP SHP SVRS JEP AUT Controller Compatibility AquaLink RS Firmware Revisions O.1 to current (T.2) Jandy Variable Speed Pumps and Pentair Intelliflo pumps communicate through the RS 485 line. PDA Firmware Revisions 4.0 to current (7.1) Jandy Variable Speed Pumps and Pentair Intelliflo pumps communicate through the RS 485 line. Z4 Firmware Revision ALL Jandy Variable Speed Pumps and Pentair Intelliflo pumps communicate through the RS 485 line but only through the filter pump circuit. JEP-R RS 485 communication - All revisions compatible. iqpump RS 485 communication - All revisions compatible.

7 Plumbing Good Plumbing Installation Minimum 2 times pipe diameter for discharge Sweep Elbow STEALTH STEALTH Minimum 4 times pipe diameter into pump! Also, if possible, plumb larger pipe on the suction side than on the discharge side. Sweep Elbow Poor Plumbing Installation Air Lock STEALTH

8 FloPro VSP Base Jandy VS FloPro Variable Speed Pump Series VS-FHP Notes: 8

9 Electrical Installation Wiring Controller of choice: JEP-R, RS, PDA, or Z4 4 conductor 22 AWG wire Circuit Breakers STEALTH GROUND WIRE BOND WIRE Note: Filter Pumps require the use of GFCI protection. (NEC ) Check local authority having jurisdiction for all other pump applications. Zodiac recommends the Siemens/Murray QF220A 20 amp breaker. Notes: 9

10 Installation Wiring FIL- PMP AUX 1 AUX 2 AUX 3 AUX 4 AUX 5 AUX 6 AUX 7 Power to independent unit running only when pump is powered ie: Salt, ozone 4 conductor 22 AWG wire Red 4 pin connector Circuit Breakers L2 L1 STEALTH GROUND WIRE Note: Filter Pumps require the use of GFCI protection. (NEC ) Check local authority having jurisdiction for all other pump applications. BOND WIRE Notes: 10

11 Installation Electrical VS-FHP ON Dip Switches: 1, 2 & 5 ON 3 & 4 Factory Setting MENU L2 L1 L2 L Red Black Yellow Green Not Used L1 = Line 1 L2 = Line VAC Ground Installation Electrical Gen II Motors Pro Series Wire 4 conductor cable to controller Green to terminal 4 Yellow to terminal 3 Black to terminal 2 Red to terminal 1 VARIABLE SPEED PUMP 230 VAC Ground L2 L1 L2 L1 Pro Series VARIABLE SPEED PUMP L2 L1

12 Auxiliary Circuit Wiring As an added feature all Gen II VS pumps with a 2014 serial number or newer come equip with the auxiliary dry contact connection. This feature allows for added safety, equipment protection, and energy efficiency. Runs chlorine generators and booster pumps only when ample flow is available, maximizing effective run time conserving energy Prevents gas production at low flow rates Avoids dry run cycles lengthening equipment life span All connections must be wired according to the National Electrical Code (NEC ), state and local codes & guidelines, and should be performed by qualified licensed personnel. Auxiliary Circuit Operation/Wiring Gen II drives with 2014 serial number or newer only Operation of Auxiliary Circuit Dry contact - single pole, single throw relay. First time the pump maintains speed above 1725 rpm for 3 + minutes the auxiliary relay closes. Pump rpm drops below 1725 rpm the auxiliary Pro Series relay opens. Pump rpm returns to 1725 or higher relay closes after 5 seconds, not 3 VARIABLE SPEED minutes. PUMP Anytime the speed drops below 1725 rpm the relay opens without a delay. Aux Circuit L2 L1

13 Auxiliary Circuit Operation/Wiring Gen II drives with 2014 serial numbers only Separate 150 VAC Power Source L2 L1 NOTE: The Auxiliary Load relay contact is rated at 11 amps whether wired for 115 or 230 VAC. Please ensure the auxiliary load does not exceed this rating. 230 VAC Power Source 115 VAC Power Source 115 VAC Auxiliary Load Separate 230 VAC Power Source L2 L1 230 VAC Power Source 230 VAC Power Source 230 VAC Auxiliary Load Drive Test and Control Bypass Gen II drives with 2014 serial number or newer only Pro Series VARIABLE SPEED PUMP L2 L1 Jump 1 to 3 and 2 to 4 Dip Switches 1 & 2 must be in the ON position.

14 Dip Switch Settings Variable Speed Controller (JEP-R) Dip Switches 1 and 2 ON epump Gen l epump Gen ll FloPro VSP 1.0 AquaLink RS or PDA Dip Switches 1 and 2 Pump Address 1 Dip Switches 3 & 4 Pump Address 2 Dip Switch 3 ON, 4 Pump Address 3 Dip Switch 3, 4 ON Pump Address 4 Dip Switch 3 & 4 ON Do not turn dip switches 1 & 2 ON unless the control panel is a JEP-R VSP Controller. By turning these two switches on, 10 volts DC is sent from the motor to the controller. If these switches are turned on, and the motor is connected to a PDA, AquaLink RS or Z4, the printed circuit board of the control will eventually fail due to 10 volts DC traveling in the wrong direction. Notes: 14

15 VSP Programming OneTouch VSP Setup JANDY AquaLinkRS 08/7/07 TUES 9:02 AM From the Main Screen highlight MENU/HELP, then press Select. FILTER PUMP AIR 88 F EQUIPMENT ON/ ONETOUCH ON/ MENU / HELP Select VSP Setup MENU HELP PROGRAM SET TEMP SET TIME DISPLAY LIGHT LOCKOUTS PASSWORD PROGRAM GROUP SYSTEM SETUP Scroll to SYSTEM SETUP and press Select.

16 VSP Setup SYSTEM SETUP VAR SPEED PUMP ONETOUCH LABEL AUX FREEZE PROTECT AIR TEMP SEASONAL ADJ DEGREES C/F DAYLIGHT SAVIN Scroll Up to VAR SPEED PUMP and press Select. MORE VSP SETTINGS PUMP MODEL PUMP APPLICATION MINI-MAX SETTINGS SPEED/LABELS PRIME RESTORE DEFAULTS Pump MODEL will be highlighted, press Select. PUMP 1 PUMP 2 PUMP 3 PUMP 4 PUMP MODEL Up to 4 variable speed or variable flow pumps maybe operated by the OneTouch. Highlight the pump number to be set and press Select. Highlight an item and press

17 VSP Setup epump Intelliflo VF Intelliflo VS VSP AC PUMP MODEL PUMP 1 X Highlight the appropriate pump type and press Select. An X will appear to the right of the pump. Press the Back button to return to VSP Settings screen. Highlight an item and press Note: Starting with Revision P a OneTouch system can operate any combination of variable speed and variable flow pumps. Note 2: Do not choose VSP AC, this circuit does not operate at this time. VSP SETTINGS PUMP MODEL PUMP APPLICATION MINI-MAX SETTINGS SPEED/LABELS PRIME RESTORE DEFAULTS Highlight PUMP APPLICATION and press Select. PUMP MODEL Highlight the pump number and press Select. PUMP 1 PUMP 2 PUMP 3 PUMP 4 Highlight an item and press

18 VSP Setup PUMP APPLICATION PUMP 1 FILTRATION AUX. PUMP NOT INSTALLED X Highlight where the pump will be used and press Select. Press the Back button to return to VSP Settings screen. Example: Pump application is as a filter pump Highlight an item and press VSP SETTINGS PUMP MODEL PUMP APPLICATION MINI-MAX SETTINGS SPEED/LABELS PRIME RESTORE DEFAULTS Highlight MIN-MAX/SETTINGS and press Select. PUMP MODEL Highlight the pump number and press Select. PUMP 1 PUMP 2 PUMP 3 PUMP 4 Highlight an item and press

19 VSP Setup MNI-MAX SETTINGS PUMP 1 SCALE MIN LIMIT MAX LIMIT RPM Highlight either MINI LIMIT or MAX LIMIT and press Select. Press the Back button to return to VSP Settings screen. Highlight an item and press MNI-MAX SETTINGS PUMP 1 SCALE MIN LIMIT MAX LIMIT Highlight an item and press RPM Press the Up or Down buttons to change the Speed, press Select when done. Press the Back button to return to VSP Settings screen. Note: Minimum and maximum speeds can be changed in 5 rpm increments. Low minimum limit is set to 600 rpm and the high maximum limit is set to 3450 rpm. To increase speed of change, hold down the Up or Down button for 5 seconds. VSP SETTINGS PUMP MODEL PUMP APPLICATION MINI-MAX SETTINGS SPEED/LABELS PRIME RESTORE DEFAULTS Highlight SPEED/LABELS and press Select. Press the Back button to return to VSP Settings screen.

20 VSP Setup PUMP MODEL Highlight the pump number and press Select. PUMP 1 PUMP 2 PUMP 3 PUMP 4 Highlight an item and press SPEED/LASBELS PUMP 1 Highlight SET SPEEDS and press Select. SET SPEEDS LABEL SPEEDS ASSIGN SPEEDS Highlight an item and press POOL SPA SPEED 3 SPEED 4 POOL HEAT SPA HEAT SOLAR HEAT SET SPEED (RPM) ^^ MORE ^^ Because Filtration was chosen earlier as the application, default speeds will be assigned to various circuits. For example, pool filtration default speed is 1750 rpm and spa filtration default speed is 2750 rpm. To change speed for any circuit simply highlight the circuit, press Select then use the Up or Down button to change speed.

21 VSP Setup ADJUST SPEED 3 (RPM) SPEED Use ARROW KEYS to set value. Then When this screen appears, the first digit in the number will be highlighted. Use the Up or Down buttons to change this digit then press Select. Do the same for the second, third and fourth digits. When the last digit is selected the screen will revert to the previous screen. All four digits must be highlighted and selected for the speed change to be recorded. In this example SPEED 3 has been changed to 2200 rpm. SPEED/LASBELS PUMP 1 Highlight LABEL SPEEDS and press Select. SET SPEEDS LABEL SPEEDS ASSIGN SPEEDS Highlight an item and press POOL SPA SPEED 3 SPEED 4 POOL HEAT SPA HEAT SOLAR HEAT SPEED 8 LABEL SPEEDS As was the case with SET SPEEDS, since Filtration was chosen earlier as the application, default labels will be assigned to various circuits. For example, pool filtration default label is POOL and spa filtration default label is SPA. To change labels for any circuit simply highlight the circuit and press Select. Note: Names such as POOL, SPA, POOL HEAT, SPA HEAT and SOLAR HEAT cannot be changed.

22 VSP Setup LABEL SPEED 3 CURRENT LABEL SPEED 3 GENERAL LABELS CUSTOM LABEL Two choices will appear on the screen, GENERAL LABELS and CUSTOM LABEL. Highlight one, then use the Up and/or Down button to change label or type the custom name. Note: Remember, at this screen the changes to the labels are changes to the speed labels not the auxiliary labels. LABEL SPEEDS POOL SPA FLOOR SYSTEM SPEED 4 POOL HEAT SPA HEAT SOLAR HEAT SPEED 8 In this example SPEED 3 has been changed to FLOOR SYSTEM. When labeling is done press the Back button to return to VSP Settings screen. Note: Remember, at this screen the changes to the labels are changes to the speed labels not the auxiliary labels. SPEED/LASBELS PUMP 1 Highlight ASSIGN SPEEDS and press Select. SET SPEEDS LABEL SPEEDS ASSIGN SPEEDS Highlight an item and press

23 VSP Setup ASSIGN SPEEDS PUMP1 Highlight one of the auxiliaries, then press Select. AUX1 AUX2 AUX3 AUX3 AUX4 AUX5 AUX6 AUX7 Example: AUX3 ASSIGN SPEEDS AUX3 POOL SPA FLOOR SYSTEM SPEED4 POOL HEAT SPA HEAT SOLAR HEAT IN FLOOR X Highlight the auxiliary to which the speed will be assigned, then press Select. Example: FLOOR SYSTEM VSP Setup FILTER PUMP SPA VSP1 SPD PGM POOL HEAT SPA HEAT SOLAR HEAT AUX1 AUX2 AUX3 AUX4 AUX5 ON ON Review Speed/Labels: At this point Speed 3 has been changed as follows: 1. Operating speed was changed from 2750 to 2200 rpm. 2. Relabeled FLOOR SYSTEM. 3. Assigned to be activated from the AUX3 circuit. vv MORE vv

24 Programming VSP Programming This section will cover two ways to JANDY AquaLinkRS 08/7/07 TUES 9:02 AM FILTER PUMP AIR 88 F Start by highlighting MENU / HELP and pressing Select. EQUIPMENT ON/ ONETOUCH ON/ MENU / HELP MENU HELP PROGRAM SET TEMP SET TIME DISPLAY LIGHT LOCKOUTS PASSWORD PROGRAM GROUP SYSTEM SETUP Scroll to PROGRAM and press Select. PROGRAM FILTER PUMP SPA VSP1 SPD PGM POOL HEAT SPA HEAT SOLAR HEAT AUX1 AUX2 vv MORE vv First way to turn on the pump automatically. Highlight the circuit and press Select. For example: To program the filter pump to turn on automatically highlight FILTER PUMP then press Select. Very Important Note: When changing speeds through programming, always set the speed to be switched to higher than the current programmed speed. Note: The items listed on this screen are the names of some of the circuits that maybe set to turn on and off automatically. To see the other circuits, press the Up or Down Button.

25 VSP Programming FILTER PUMP Add Program will be highlighted, press Select. NO PROGRAMS ENTERED ADD PROGRAM ON ALL DAYS FILTER PUMP NEW PROGRAM Use ARROW KEYS to set value. Then 1:00 PM 1:00 PM When this screen appears the default ON and times will show as 1:00 PM and the ON hour will be highlighted. To change the ON hour press the Up or Down button. Note the AM/PM indicator as the hour is changed, then press Select. Next change the on minutes and press Select. Set the time in the same manner. Finally chose whether the pump should run everyday (All Days), on individual days, on weekdays or just on weekends, then press Select. Example: The Filter Pump circuit is now programmed to turn on everyday at 8:00 AM and off at 5:00 PM. FILTER PUMP NEW PROGRAM ON ALL DAYS Use ARROW KEYS to set value. Then 8:00 AM 5:00 PM As shown here the Filter Pump circuit is now programmed to turn on everyday at 8:00 AM and off at 5:00 PM. Follow the same procedure for setting other circuits to turn on/off automatically.

26 VSP Programming AUX3 NEW PROGRAM ON ALL DAYS Use ARROW KEYS to set value. Then 11:00 AM 1:00 PM Here the AUX3 circuit has been programmed to turn on everyday at 11:00 AM and off at 1:00 PM. Remember: AUX3 circuit has been previously assigned speed label FLOOR SYSTEM which has speed setting 2200 rpm set. FILTER PUMP NEW PROGRAM ON ALL DAYS Use ARROW KEYS to set value. Then 8:00 AM 5:00 PM AUX3 NEW PROGRAM Review: Programmed, as shown in these two examples, the VSP will turn on at 8:00 AM and, after priming is complete, run at 1750 rpm. At 11:00 the speed will increase to 2200 rpm (AUX3/FLOOR SYSTEM speed), and run at this speed until 1:00 PM. From 1:00 PM until the pump turns off at 5:00 PM it will return to the filtration speed of 1750 rpm. ON ALL DAYS 11:00 AM 1:00 PM Use ARROW KEYS to set value. Then

27 VSP Programming PROGRAM FILTER PUMP SPA VSP1 SPD PGM POOL HEAT SPA HEAT SOLAR HEAT AUX1 AUX2 Second way to turn on the pump automatically. Highlight VSP1 SPD PGM and press Select. VSP SPD PGM allows program times to be set so the variable speed pump will change speeds within a programmed operational time without using additional circuits such as POOL HEAT, SPA, SPA HEAT, or auxiliaries. vv MORE vv PROGRAM FILTER PUMP SPA VSP1 SPD PGM POOL HEAT SPA HEAT SOLAR HEAT AUX1 AUX2 Very Important Note: The same requirement as Program applies when setting VSP SPD PGM, that is, ALWAYS SET THE SWITCHING SPEED HIGHER THAN THE PREVIOUS SPEED. vv MORE vv PROGRAM SPEEDS POOL SPA FLOOR SYSTEM SPEED 4 POOL HEAT SPA HEAT SOLAR HEAT SPEED 8 At this screen the pump maybe programmed to change to any of the 8 speeds within an operating time without using up an equipment circuit to do so. For example: If the pool filtration pump is set to run at 1750 rpms from 8:00 AM to 5:00 PM and the FLOOR SYSTEM is set to run from 11:00 AM to 2:00 PM at 2200 rpms, the following will occur. The filter pump will turn on at 8:00 AM and go to the priming speed and run at that speed for the priming duration. The pump will then switch to the set speed of 1750 rpms until 11:00 AM. At 11:00 AM the pump will ramp up to 2200 rpms and run at that speed until 2:00 PM. From 2:00 PM until it shuts off at 5:00 PM the pump will again operate at 1750 rpms.

28 VSP Programming PROGRAM FILTER PUMP SPA VSP1 SPD PGM POOL HEAT SPA HEAT SOLAR HEAT AUX1 AUX2 vv MORE vv PROGRAM FILTER PUMP SPA VSP1 SPD PGM POOL HEAT SPA HEAT SOLAR HEAT AUX1 AUX2 vv MORE vv Review: Use PROGRAM to set the equipment to operate automatically using circuits. Set PROGRAM SPEEDS (VSP SPD PGM) to change speed for equipment within its automatic operating time. Always set the switch to speed higher than the switch from speed. Note: If more than one variable speed/flow pump is installed there will be additional VSP SPD PGM listed on this screen. For example if there are 4 epump installed they will be listed as follows: VSP2 SPD PGM VSP3 SPD PGM VSP4 SPD PGM Notes: 28

29 Manual Operation JANDY AquaLinkRS 08/7/07 TUES 9:02 AM FILTER PUMP AIR 88 F EQUIPMENT ON/ ONETOUCH ON/ MENU / HELP There are two ways to change speeds Manually, both are selected through the EQUIPMENT ON/ screen. To change speeds manually highlight EQUIPMENT ON/ from the main screen and press Select. FILTER PUMP SPA VSP1 SPD ADJ POOL HEAT SPA HEAT SOLAR HEAT AUX1 AUX2 AUX3 AUX4 AUX5 First way to change speeds manually. If a speed has been assigned to a circuit, highlight the circuit and press Select. After priming the pump will go to the speed set to that circuit. Example: AUX1 selected. After priming the pump will run at the speed set to AUX1. ^^ MORE ^^ FILTER PUMP SPA VSP1 SPD ADJ POOL HEAT SPA HEAT SOLAR HEAT AUX1 AUX2 AUX3 AUX4 AUX5 ON Second way to change speeds manually. Highlight the circuit for the pump application and press select to turn on this circuit. Example: Pump application is filtration therefore the FILTER PUMP circuit must be turned on first. ^^ MORE ^^

30 VSP Manual Operation FILTER PUMP SPA VSP1 SPD ADJ POOL HEAT SPA HEAT SOLAR HEAT AUX1 AUX2 AUX3 AUX4 AUX5 ON Scroll to VSP1 SPD ADJ and press Select. Note there maybe more than one VSP SPD ADJ, so chose the appropriate pump. ^^ MORE ^^ SET SPEED (RPM) Highlight a speed, then press Select. POOL SPA FLOOR SYSTEM SPEED 4 POOL HEAT SPA HEAT SOLAR HEAT ^^ MORE ^^ SPEED4 SET TO 1200 RPM Use ARROW KEYS To set value. Then When this screen appears, the first digit in the number will be highlighted. Use the Up or Down buttons to change this digit then press Select. Do the same for the second, third and fourth digits. When the last digit is selected the screen will revert to the previous screen and the pump will run at the speed selected. All four digits must be highlighted and selected for the speed change to be recorded. In this example SPEED4 has been changed to from 2750 to 1200 rpm.

31 VSP Manual Operation SERVICE MODE When in SERVICE or TIME OUT MODE, the pump will run at the priming speed. NO OPERATIONS ALLOWED HERE ON RESET POOL MODE AUTO SPA MODE SERVICE HEATER SOLAR SPA DRAIN TIME OUT SPA FILL ON FIL- PMP AUX 1 AUX 2 AUX 3 AUX 4 AUX 5 AUX 6 AUX 7 INTAKE RETURN CLEANER SOLAR SLR-PMP E-HTR SPARE Notes: 31

32 Troubleshooting Confirm Compatibility JANDY AquaLinkRS 08/7/07 TUES 9:02 AM FILTER PUMP AIR 88 F From the main screen highlight MENU / HELP then press Select. EQUIPMENT ON/ ONETOUCH ON/ MENU / HELP MENU HELP PROGRAM SET TEMP SET TIME DISPLAY LIGHT LOCKOUTS PASSWORD PROGRAM GROUP SYSTEM SETUP HELP will be highlighted, press Select. Notes: 32

33 Troubleshooting HELP Choose a topic with arrow keys and press Scroll to DIAGNOSTICS and press Select. GO KEYS SERVICE DIAGNOSTIS MODEL E TYPE RS-8 Combo FIRMWARE R Look for the FIRMWARE number in Diagnostics. The Firmware must be revision O or newer. Example: The revision of this system is R. SENSORS WATER AIR SOLAR OK OK OK NEXT Notes: 33

34 Troubleshooting Confirm Communication MODEL E TYPE RS-8 Combo FIRMWARE R If the revision letter is correct, press Select to go to the NEXT screen. SENSORS WATER AIR SOLAR OK OK OK NEXT REMOTES epump CHEMLINK ONETOUCH SERIAL ADAPTER All items connected through the RS485 line will appear on this screen. If the epump is listed check the number to its right making certain it coincides with the address of the pump. CONTINUE Notes: 34

35 Troubleshooting ERRORS epump RS485 ERROR CONTINUE 1 At this screen any communication issues with the connection to the RS485 line will be shown. This screen indicates any of the following: 1. The RS485 line (4 conductor wire) is damaged or not connected properly. 2. Power is off to the motor when it should be on. 3. epump is damaged. REMOTES epump CHEMLINK ONETOUCH SERIAL ADAPTER CONTINUE Example: Here the epump is addressed as epump 2. If this is not the correct address of the epump the dip switches, located in the junction box at the rear of the epump, will need to be changed. If the address is correct, press Select to continue. Notes: 35

36 Affinity Law Up to 90% Annual Energy Savings Pump Affinity Law shows the relationship between volume capacity (gpm), head (pressure or resistance) and power consumption of a pump due to changes in speed (rpm). Holds true for: Highly efficient permanent magnet motors, such as variable speed pumps. Does not hold true for: Standard induction motors, such as single and two speed pumps. What does this mean? Notes: 36

37 Pump Affinity Law Simplified The simplified version that you need to understand: When reducing the pump speed by 1/2: the flow reduces by 1/2; the head (pressure of resistance) reduces to approximately ¼ of the original high speed resistance; the energy consumption reduces to 1/8 of the original high speed energy consumption. Flow as Speed Changes Energy saved through speed reduction is MUCH GREATER than savings through improved motor efficiency.

38 Pump Affinity Law Example Jandy epump installed with 3 inch plumbing, running at a max speed of 3450 rpm, at 140 gpm, and at a head loss is 5.6 ft of head per 100 ft of pipe. By reducing the speed by half: Pump Speed: /2 Flow (gpm): Ft of Head: Pump Operating Cost: /2 1/4 1/8 As the flow rate is reduced, you must increase the run time to meet turn over requirements. Power Consumption Low Speed 30 GPM 850 RPM One Light Bulb PUMP AFFINITY LAW indicates the influence on volume capacity (gpm) and power consumption of a pump due to changes in speed (rpm). Half Speed 400 W 60 GPM 1725 RPM 4 Light Bulbs 20 Light Bulbs 100 Watt Light Bulb High Speed 120 GPM Flow RPM 3450 RPM % of Speed 0% 25% 50% 75% 100%

39 LONG TERM COST SAVINGS Single VSP Pump Operating Cost per/hr: $.12 $ HR 24 HR Pump Operating 12 hr/per day: Pump Operating 150 days: Pump Operating 365 days: Pump Operating days: Pump Operating days: $1.44 $.36 $216 $54 $525 $131 $1080 $270 $2625 $655 As the flow rate is reduced, you must increase the run time to meet turn over requirements. Jandy JEP Pump Curve

40 Two 1½" Pipes or One 3 Pipe" Which is better for Flow? 1½" 3" One 3" = 4.71 sq" Or 1½" Two 1½" = 3.53 sq" Area of a Circle ~ r 2 Notes: 40

41 Determining Head Loss Per 100' of Pipe U.S. 3/4" Pipe 1" Pipe 1 1/4" Pipe 1 1/2" Pipe 2" Pipe 2 1/2" Pipe 3" Pipe 4" Pipe 6" Pipe U.S. Gals. Vel. Loss Vel. Loss Vel. Loss Vel. Loss Vel. Loss Vel. Loss Vel. Loss Vel. Loss Vel. Loss Gals. per Ft. per in Ft. per in Ft. per in Ft. per in Ft. per in Ft. per in Ft. per in Ft. per in Ft. per in per Min. Sec. Feet Sec. Feet Sec. Feet Sec. Feet Sec. Feet Sec. Feet Sec. Feet Sec. Feet Sec. Feet Min U.S GAL PER MIN. 8" PIPE U.S GAL PER MIN. 10" PIPE Based on Williams & Hazen Formula Using Constant 150, Sizes of Standard Pipe in Inches. Based Friction Williams Loss & of Hazen Water Formula in Feet per Using 100 Constant Feet Length 150, of Sizes Pipe of Standard Pipe in Inches. Friction/Flow Chart for Schedule 40 Rigid PVC Pipe Friction Loss of Water in Feet per 100 Feet Length of Pipe

42 Determining Head Loss Per 100' of Pipe Friction/Flow Chart for Schedule 40 Rigid PVC Pipe Based on Williams & Hazen Formula Using Constant 150, Sizes of Standard Pipe in Inches. As an example: At 40 GPM what is the Head Loss in 100 feet of 1.5 inch straight PVC pipe? 8.90 Friction Loss of Water in Feet per 100 Feet Length of Pipe Based on Williams & Hazen Formula Using Constant 150, Sizes of Standard Pipe in Inches. As an example: At 40 GPM what is the Head Loss in 100 feet of 2 inch straight PVC pipe? 2.63 Twice the gpm equals four times the resistance!!! Friction Loss of Water in Feet per 100 Feet Length of Pipe

43 Determining Head Loss Per 100' of Pipe Friction/Flow Chart for Schedule 40 Rigid PVC Pipe Based on Williams & Hazen Formula Using Constant 150, Sizes of Standard Pipe in Inches. As an example: At 80 GPM what is the Head Loss in 100 feet of 2 inch straight PVC pipe? 9.50 Friction Loss of Water in Feet per 100 Feet Length of Pipe Based on Williams & Hazen Formula Using Constant 150, Sizes of Standard Pipe in Inches. As an example: At 80 GPM what is the Head Loss in 100 feet of 1.5 inch straight PVC pipe? Exceeds Pipe Limit Friction Loss of Water in Feet per 100 Feet Length of Pipe

44 Don't forget the fittings Head loss Fittings value 1" 1½" 2" 2½" 3" STANDARD 90º ELBOW STANDARD 45º ELBOW INSERT COUPLING GATE VALVE TEE FLOW THROUGH RUN TEE FLOW THROUGH BRANCH GLOBE VALVE Notes: 44

45 3 Simple Steps to Variable Speed Success 1. Calculate your 8 hour turn over rate 2. Determine equipment flow minimums 3. Calculate new turnover run time Notes: 45

46 Calculate the pool size in gallons Step 1: Calculate the Turnover Rate Length x width x average depth x 7.5 (7.5 = approximate number of gallons in 1 cubic foot of water) Example: 40' x 20' x 4.8' x 7.5 = 28,800 gallons 20" 40' Average Depth 4.8' The length of time it takes for the circulation system to filter an amount equal to the amount of water in the pool. Generally one to four turnovers per day (6 to 8 hrs), some local commercial codes are higher. Gallons # of hrs x 60 = GPM Use 8 hour turnover rate Example: 28,800 gallons (8 x 60) = 60 GPM

47 Step 2: Determine Equipment Flow Minimums A few examples of minimum flow requirements: Skimmers.. 25 gpm/skimmer * APSP15 requires a minimum of 25 gpm per skimmer. The weir door must pull down to operate correctly. Some skimmers require more gpm to operate. Heaters 35 gpm D.E. filters gpm * Minimum flow to keep D.E. on grids. Salt Water Chlorinators gpm Step 3: Calculate New Turnover Run Time Each pool will be different. The key to the greatest energy savings is to run the pump at the lowest minimum speed for the equipment that is in operation when filtering and, if necessary, sanitizing the pool. 1. Enter the number of gallons of the pool: 28, Enter minimum filtration flow rate for equipment: Divide # of gallons by the minimum flow rate: (Ex: 28,800 / 30 = 960, which is # of filtration mins) 4. Divide # of minutes by 60 to find filtration hours: (Ex: 960 / 60 = 16 hours, which is new filtration run time)

48 Calculate the existing Feet of Head Vacuum x 1.13 = Suction head Pressure x 2.31 = Discharge head Added together equals Total Dynamic Head PSI Vacuum Calculate the existing Feet of Head Vacuum = 10 Pressure = 9 (Vacuum) 10 x 1.13 = (Pressure) 9 x 2.31 = Total head in system = 32.09

49 Notes:

50

SPARUS PUMP WITH CONSTANT FLOW TECHNOLOGY

SPARUS PUMP WITH CONSTANT FLOW TECHNOLOGY AQUATIC ECO-SYSTEMS SPARUS PUMP WITH CONSTANT FLOW TECHNOLOGY INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS i CUSTOMER SERVICE / TECHNICAL

More information

Variable Speed Pump and Drive Technical Guide

Variable Speed Pump and Drive Technical Guide Variable Speed Pump and Drive Technical Guide 2011 Hayward Pool Products Version 2 Drive FW 1.02 Interface FW 2.56 residential Interface FW 1.01 commercial Table of Contents Safety Precautions Page 1 Installation

More information

Part Number: kW 800 Incoloy Element kW 800 Incoloy Element With 4kW Titanium Element kW 800 Titanium Element

Part Number: kW 800 Incoloy Element kW 800 Incoloy Element With 4kW Titanium Element kW 800 Titanium Element BP500 Tech Sheet Balboa Water Group Part Number: 55697-04 4kW 800 Incoloy Element 55967-03 3kW 800 Incoloy Element 55700-04 With 4kW Titanium Element 55968-03 3kW 800 Titanium Element Compatible Plumbing

More information

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

3 FT CORD Models , , , FT CORD W/GFCI Models , , , POWERLINE XP II Swimming Pool Pump (Light Oak color model) With Automatic Timer 3 FT CORD Models 0-1395-226, 0-1396-226, 0-1397-226, 0-1398-226 25 FT CORD W/GFCI Models 0-1395-220, 0-1396-220, 0-1397-220,

More information

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , , POWERLINE XP I Swimming Pool Pump (Light Oak color model) 3 FT CORD UL/NEC Models 0-1295-206, 0-1296-206, 0-1297-206, 0-1298-206 25 FT CORD w/gfci UL Models 0-1295-200, 0-1296-200, 0-1297-200, 0-1298-200

More information

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light installation Manual English Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified

More information

Jandy Pro Series NeverLube and Backwash Valve

Jandy Pro Series NeverLube and Backwash Valve installation and Operation Manual English Jandy Pro Series NeverLube and Backwash Valve FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in pool

More information

AquaPure Ei TM Series Replacement Kits

AquaPure Ei TM Series Replacement Kits AquaPure Ei TM Series Replacement Kits for Models APURE35/35C WARNING FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the

More information

Troubleshooting Manual

Troubleshooting Manual DISPLAY HOLD/RELEASE SPA AUX 1 AUX 2 AUX 3 AUX 4 AUX 5 AUX 6 AUX 7 Troubleshooting Manual HEATERS POOL SPA SOLAR MENU CANCEL BACK FORWARD ENTER Table of Contents This is the Troubleshooting Manual for

More information

INTELLIFLOXF AND INTELLIPROXF VARIABLE SPEED ULTRA ENERGY EFFICIENT PUMP

INTELLIFLOXF AND INTELLIPROXF VARIABLE SPEED ULTRA ENERGY EFFICIENT PUMP INTELLIFLOXF AND INTELLIPROXF VARIABLE SPEED ULTRA ENERGY EFFICIENT PUMP INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS P/N 353061

More information

ENGINEERING DATA ENGINEERING DATA

ENGINEERING DATA ENGINEERING DATA ENGINEERING DATA 173 Average Depth 3.5 ft. 24 ft. Dia. ESTIMATING TOTAL GALLONS IN A POOL OR SPA Width Length Depth (deep) Depth (shallow) Radius 2 x 3.14 x A.D. x 7.5 = Gallons 12 x 12 x 3.14 x 3.5 x

More information

INTELLIFLO VSF VARIABLE SPEED AND FLOW PUMP

INTELLIFLO VSF VARIABLE SPEED AND FLOW PUMP INTELLIFLO VSF VARIABLE SPEED AND FLOW PUMP INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS i CUSTOMER SERVICE / TECHNICAL SUPPORT If

More information

VARIABLE SPEED ULTRA ENERGY EFFICIENT PUMP

VARIABLE SPEED ULTRA ENERGY EFFICIENT PUMP INTELLIFLO VARIABLE SPEED ULTRA ENERGY EFFICIENT PUMP INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS i CUSTOMER SERVICE / TECHNICAL

More information

INTELLIFLO VARIABLE SPEED PUMP

INTELLIFLO VARIABLE SPEED PUMP INTELLIFLO VARIABLE SPEED PUMP INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS i CUSTOMER SERVICE / TECHNICAL SUPPORT If you have questions

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Universal Air Series!! NOTE!! Covers the following model: 6000 Series 85-0100B-AZ Rev 0 5/07 To ensure that the system is installed properly, provide your electrician with these

More information

VARIABLE SPEED USER MANUAL. Premium Efficiency Variable Speed Motor

VARIABLE SPEED USER MANUAL. Premium Efficiency Variable Speed Motor VARIABLE SPEED USER MANUAL Premium Efficiency Variable Speed Motor SAFETY Safety is emphasized throughout the user manual. These are safety alert symbols. They alert the user to potential personal injury

More information

INTELLIVALVE 2-WAY, 3-WAY VALVE ACTUATOR

INTELLIVALVE 2-WAY, 3-WAY VALVE ACTUATOR INTELLIVALVE 2-WAY, 3-WAY VALVE ACTUATOR Press MODE button to toggle between: AUTO Mode (Green LED on): The IntelliValve Valve Actuator is controlled automatically when connected to a supported automation

More information

Installation and Operation Manual

Installation and Operation Manual Installation and Operating Data Installation and Operation Manual Jandy Laminar Jet Pulse Controller LPC4 H0566900A WARNING FOR YOUR SAFETY - This product must be installed and serviced by a pro fes sion

More information

TAURUS VS VARIABLE SPEED PUMP

TAURUS VS VARIABLE SPEED PUMP AQUATIC ECO-SYSTEMS TAURUS VS VARIABLE SPEED PUMP INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS i CUSTOMER SERVICE / TECHNICAL SUPPORT

More information

IntelliTouch Pool and Spa Control System Load Center and Power Center

IntelliTouch Pool and Spa Control System Load Center and Power Center pool/spa control system IntelliTouch Pool and Spa Control System Load Center and Power Center IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Installation Guide 2008

More information

WARNING FOR YOUR SAFETY:

WARNING FOR YOUR SAFETY: Installation and Operating Data Installation and Operation Manual epump Series Pumps FOR YOUR SAFETY: This product must be in stalled and serviced by a professional service technician, qualified in pool/spa

More information

Installation and Operation Manual. FloPro Series Pumps WARNING. Model FHPM

Installation and Operation Manual. FloPro Series Pumps WARNING. Model FHPM Installation and Operating Data Installation and Operation Manual FloPro Series Pumps Model FHPM FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified

More information

INTELLIFLO VSF VARIABLE SPEED AND FLOW PUMP

INTELLIFLO VSF VARIABLE SPEED AND FLOW PUMP INTELLIFLO VSF VARIABLE SPEED AND FLOW PUMP INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS i CUSTOMER SERVICE / TECHNICAL SUPPORT If

More information

STA-RITE INTELLIPRO 2 VST VARIABLE SPEED PUMP

STA-RITE INTELLIPRO 2 VST VARIABLE SPEED PUMP STA-RITE INTELLIPRO 2 VST VARIABLE SPEED PUMP INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS i CUSTOMER SERVICE / TECHNICAL SUPPORT

More information

Jandy Pro Series Water Feature Pump Model WFTR INSTALLATION AND OPERATION MANUAL WARNING ENGLISH

Jandy Pro Series Water Feature Pump Model WFTR INSTALLATION AND OPERATION MANUAL WARNING ENGLISH INSTALLATION AND OPERATION MANUAL ENGLISH Jandy Pro Series Water Feature Pump Model WFTR FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in pool

More information

OnCommand Troubleshooting Guide Hayward Industries

OnCommand Troubleshooting Guide Hayward Industries OnCommand Troubleshooting Guide 2010 Hayward Industries Table of Contents Safety Precautions Page 1 Overview Pages 2-5 Software Troubleshooting Page 6 Local Display Pages 7-8 Relays Pages 9-10 Heaters

More information

Installation Instructions & Users Manual

Installation Instructions & Users Manual Installation Instructions & Users Manual UTILITY/ BUILDING INPUT 120 VAC ( OPTION) 15-20A N L CONTROL BOARD G SECURITY LIGHTING POWER SUPPLY (OPTION) CHARGER- POWER SUPPLY ASSBY XFMR (OPTION) CBM MODEL

More information

INTELLICHLOR SALT CHLORINATOR COMMERCIAL SYSTEM COMSYS-8 (P/N )

INTELLICHLOR SALT CHLORINATOR COMMERCIAL SYSTEM COMSYS-8 (P/N ) INTELLICHLOR SALT CHLORINATOR COMMERCIAL SYSTEM COMSYS-8 (P/N 520973) INSTALLATION GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS P/N 520983 Rev. B 1/2016

More information

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System Installation Instructions DuraMAC TM Light Commercial & Irrigation Water Pressure Booster System The DuraMAC TM Water Pressure Booster System is the first booster pump of its kind to be designed for virtually

More information

Pool Pumps - In-Ground / Universal Booster Pump

Pool Pumps - In-Ground / Universal Booster Pump - In-Ground / Universal Booster Pump Suitable for all swimming pool pressure cleaners. Best replacement for any 3/4 HP booster pump. Optimized for reliability, durability & efficiency. Comes with a tall,

More information

Pool Pumps - In-Ground / Universal Booster Pump

Pool Pumps - In-Ground / Universal Booster Pump - In-Ground / Universal Booster Pump Suitable for all swimming pool pressure cleaners. Best replacement for any 3/4 HP booster pump. Optimized for reliability, durability & efficiency. Comes with a tall,

More information

POOL BARON Nicheless Color Changing LED Pool Light

POOL BARON Nicheless Color Changing LED Pool Light POOL BARON Nicheless Color Changing LED Pool Light SPECIFICATIONS: An RGB color changing pool light featuring 16 preprogrammed color modes, including white. Featuring the latest and brightest mid-power

More information

SuperFlo 9,000 High Volume Pump Product Manual

SuperFlo 9,000 High Volume Pump Product Manual SuperFlo 9,000 High Volume Pump Product Manual For Model: SuperFlo 9,000 (Item #120225) Table of Contents: Important Information... 2 Technical Specs... 3-4 Installing Your SuperFlo Pump... 4-5 Cleaning

More information

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS The DuraMAC TM Water Pressure Booster System is the first booster pump of its kind to be designed for virtually

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Universal Air Series!! NOTE!! Covers the following models: 9000 Series 6000 Series To ensure that the system is installed properly, provide your electrician with these instructions.

More information

Replacement Motors G 183

Replacement Motors G 183 Replacement Motors G 183 Replacement Lomart / Doughboy Motors W000134.000 BV91 (L.S.) Century 1 hp Single Speed 115V 10 Amp 1.0 S.F. (1.0 T.H.P.) Left Hand Thread Lomart & Doughboy Replacement Thru-Bolt

More information

INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information INSTALLATION INSTRUCTIONS Solid-State Series!! NOTE!! Covers the following models: " CS6100 - CS7100 " CS6200 - CS9200 " CS6220 - CS9220 " CS6230 - CS9230 " CS6500 - CS7500 " CS6330 - CS9300 " CS9400 -

More information

Jazz/FX Series Spa Light Jazz Series 120 Volt only FX Series 120 Volt or 12Volt. Owners Manual

Jazz/FX Series Spa Light Jazz Series 120 Volt only FX Series 120 Volt or 12Volt. Owners Manual Jazz/FX Series Spa Light Jazz Series 120 Volt only FX Series 120 Volt or 12Volt Owners Manual Fiberstars 44259 Nobel Drive Fremont, CA 94538 www.fiberstars.com 79-15014-00 REV B - 1 - CAREFULLY READ AND

More information

SUPERFLO VS VARIABLE SPEED PUMP

SUPERFLO VS VARIABLE SPEED PUMP SUPERFLO VS VARIABLE SPEED PUMP INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS i CUSTOMER SERVICE / TECHNICAL SUPPORT If you have questions

More information

MAGICBOWL WATER EFFECT WITH FIREFX LED LIGHT FOR POOL AND SPA

MAGICBOWL WATER EFFECT WITH FIREFX LED LIGHT FOR POOL AND SPA MAGICBOWL WATER EFFECT WITH FIREFX LED LIGHT FOR POOL AND SPA INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS COLORFX Water Bowl Installation

More information

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications WPC-1 Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH POOL AND

More information

SpaCommand Spa-Side Remote (For EasyTouch, IntelliTouch and Compool CP3800 Series Control Systems)

SpaCommand Spa-Side Remote (For EasyTouch, IntelliTouch and Compool CP3800 Series Control Systems) SpaCommand Spa-Side Remote (For EasyTouch, IntelliTouch and Compool CP3800 Series Control Systems) Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE

More information

Replacement Motors G 183

Replacement Motors G 183 Replacement Motors G 183 Replacement Lomart / Doughboy Motors W000130.000 BV90 (L.S.) Century 1 hp Single Speed 115V 10 Amp $260.00 1.0 S.F. (1.0 T.H.P.) Right Hand Thread Lomart & Doughboy Replacement

More information

JAZZ J400C (COLOR), J400AS (AUTO SYNC)

JAZZ J400C (COLOR), J400AS (AUTO SYNC) Fiberstars JAZZ J400C (COLOR), J400AS (AUTO SYNC) Owners Manual Fiberstars 44259 Nobel Drive Fremont, CA 94538 www.fiberstars.com Rev.E 08/04/04-1 - P/N 75-15046-PM CAREFULLY READ AND FOLLOW ALL SAFETY

More information

IntelliPro VS-3050 Variable Speed Swimming Pool Pump. Quick-Start Guide. Step-by-step instructions for easy set-up and operation

IntelliPro VS-3050 Variable Speed Swimming Pool Pump. Quick-Start Guide. Step-by-step instructions for easy set-up and operation IntelliPro VS-3050 Variable Speed Swimming Pool Pump Quick-Start Guide Step-by-step instructions for easy set-up and operation Table of Contents PAGE 1 Before You Get Started 2 The Performance Secret 4

More information

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP OWNER S MANUAL Pond Pump READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP Important Notice: This manual contains important information about the installation, operation and safe use of this product. This

More information

Non-qualifi ed users should never open or remove covers, as this will expose dangerous voltage points and other serious risks.

Non-qualifi ed users should never open or remove covers, as this will expose dangerous voltage points and other serious risks. End User Disclaimer End User Disclaimer: United Spa Controls systems have absolutely no end user serviceable parts. United Spa Controls does not authorize attempts by the spa owner/ user to install or

More information

INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION & OPERATING INSTRUCTIONS INSTALLATION & OPERATING INSTRUCTIONS WARNING RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A CIRCUIT PROTECTED BY A GROUND-FAULT CIRCUIT-INTERRUPTER. THE UNIT SHOULD BE INSTALLED BY A QUALIFIED SERVICE REPRESENTATIVE.

More information

INTELLIPRO VARIABLE SPEED ULTRA ENERGY EFFICIENT PUMP

INTELLIPRO VARIABLE SPEED ULTRA ENERGY EFFICIENT PUMP INTELLIPRO VARIABLE SPEED ULTRA ENERGY EFFICIENT PUMP INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS i CUSTOMER SERVICE / TECHNICAL

More information

User Manual Solar Charge Controller 3KW

User Manual Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW Version: 1.3 CONTENTS 1 ABOUT THIS MANUAL... 1 1.1 Purpose... 1 1.2 Scope... 1 1.3 SAFETY INSTRUCTIONS... 1 2 INTRODUCTION... 2 2.1 Features... 2 2.2 Product Overview...

More information

Operations Manual. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

Operations Manual. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL Operations Manual Automated Fuel Maintenance System FTI-10A & 20A FUEL TECHNOLOGIES INTERNATIONAL Replacement Manuals Available on Website: www.fueltechnologiesinternational.com 07/15/2015 Rev E Fuel Technologies

More information

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications WPC1-XXXX-T Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH

More information

Zodiac VS FloPro Variable-Speed Pump Series E3 INSTALLATION AND OPERATION MANUAL WARNING ENGLISH

Zodiac VS FloPro Variable-Speed Pump Series E3 INSTALLATION AND OPERATION MANUAL WARNING ENGLISH INSTALLATION AND OPERATION MANUAL ENGLISH Zodiac VS FloPro Variable-Speed Pump Series E3 H0394700 Rev A FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and

More information

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE QUICK START GUIDE OWNER S MANUAL SAFETY, INSTALLATION, OPERATION & PARTS AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL 877-278-2797 DO NOT RETURN TO STORE! WARNING This equipment must be installed

More information

PART B BRAND SPECIFIC MANUAL

PART B BRAND SPECIFIC MANUAL SPA OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS PART B BRAND SPECIFIC MANUAL ELECTRICAL CONNECTION KEYPAD OPERATION 200 Series 200-M-B-16 Read in conjunction with Part A General Manual to form a complete

More information

pumps VARIABLE SPEED PUMPS HAYWARD ECOSTAR PUMP FEATURES:

pumps VARIABLE SPEED PUMPS HAYWARD ECOSTAR PUMP FEATURES: HAYWARD ECOSTAR PUMP FEATURES: SP3400VSP 2.7HP ECO STAR VARIABLE SPEED PUMP $ 2,358.85 SP3400VSPVR 2.7HP ECO STAR VARIABLE SPEED PUMP - SVRS $ 2,761.55 HAYWARD MAXFLO PUMP FEATURES: VARIABLE SPEED PUMPS

More information

BLOWER PERFORMANCE CHART

BLOWER PERFORMANCE CHART Technical Information / Blower Sizing Friction loss of water in feet of head per 100 foot length of pipe. 1. Calculate water depth in inches: A. Actual water depth in injector = B. Add ½" of water per

More information

Technical FAQs Technical and Basic Pool Information

Technical FAQs Technical and Basic Pool Information Technical FAQs Technical and Basic Pool Information I. FILTRATION SYSTEM 1- WHICH FILTRATION UNIT IS IT? a) 2 BAGS IS IT A PF 98 OR A PF 2000? PF 98 (from 98 till May 2002) PF 2000 (May 2002-May 2011)

More information

User Manual. Solar Charge Controller 3KW

User Manual. Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5

More information

PRE-PLUMBED SEWAGE SYSTEM

PRE-PLUMBED SEWAGE SYSTEM PRE-PLUMBED SEWAGE SYSTEM Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1910-0009 Español p. 13 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems,

More information

GTFM IV. Operation / Installation Manual. Gas Turbine Flow Monitor. Computer Weld Technology, Inc. Manual Part Number: A8M5010 Revised: June 26, 2008

GTFM IV. Operation / Installation Manual. Gas Turbine Flow Monitor. Computer Weld Technology, Inc. Manual Part Number: A8M5010 Revised: June 26, 2008 Computer Weld Technology, Inc. 10702 Old Bammel N Houston Rd. Houston, TX 77086 Phone: (713) 462-2118 Fax: (713) 462-2503 Email: cwt@cweldtech.com GTFM IV Gas Turbine Flow Monitor Operation / Installation

More information

Owners Manual: - Pumps

Owners Manual: - Pumps Owners Manual: - Pumps GENERAL SAFETY RULES 1. The products mentioned in this manual are specially designed for the pre-filtering and re-circulation of water in swimming pools and spas. 2. They are designed

More information

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP OWNER S MANUAL Swimming Pool Pump READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP Important Notice: This manual contains important information about the installation, operation and safe use of this product.

More information

BULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS

BULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS BULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS FEATURES NEMA 3R Enclosure: Rainproof, outdoor/ indoor rated enclosure. Current

More information

SOLAR AQUA. Operation and Installation Manual LDLINE AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP. Electronic Solar Control Center. for models CONTROLS INC.

SOLAR AQUA. Operation and Installation Manual LDLINE AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP. Electronic Solar Control Center. for models CONTROLS INC. AQUA SOLAR TM Electronic Solar Control Center Operation and Installation Manual for models AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP G LDLINE CONTROLS INC. www.goldlinecontrols.com 888-921-7665 IMPORTANT SAFETY

More information

HALLMARK INDUSTRIES INC

HALLMARK INDUSTRIES INC Performance Part No. HP. CONVERTIBLE JET PUMP USER S MANUAL GPH of Water @ Total Discharge Pressure of 40 psi Max. Pressure Max suction (shallow well) Max Suction (deep well) Max GPM (@0 head) Max Discharge

More information

Pool Skimmers and Skim Filters / Renegade Gunite In-Ground Skimmers

Pool Skimmers and Skim Filters / Renegade Gunite In-Ground Skimmers Pool Skimmers and Skim Filters / Renegade Gunite In-Ground Skimmers NSF Approved with Flow Rate of 75 GPM PVC sockets for better glue joints 2" socket is 2 1/2" spigot for more flow 1 1/2" socket is 2"

More information

Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, p/n Revision 0

Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, p/n Revision 0 Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, p/n 107065-01 Revision 0 May 20, 2016 Contents Introduction 2 Installation Pre-installation 3 Installation Procedure 4 Electrical

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS OWNER S MANUAL FLO-MASTER XP2 SERIES PUMPS IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:

More information

AQUA SOLAR. Operation and Installation Manual AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP. Electronic Solar Control Center. for models CON TROLS

AQUA SOLAR. Operation and Installation Manual AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP. Electronic Solar Control Center. for models CON TROLS AQUA SOLAR TM Electronic Solar Control Center Operation and Installation Manual for models AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP G LDLINE CON TROLS www.goldlinecontrols.com IMPORTANT SAFETY INSTRUCTIONS

More information

Instruction & Owner s Manual

Instruction & Owner s Manual Instruction & Owner s Manual Table of Contents Page Installation - Plumbing of Chamber 3 Installation - Electronic Control Box 3-4 Transformer Connection 115VDC or 230VDC 4-5 Instructions for use with

More information

WARNING FOR YOUR SAFETY:

WARNING FOR YOUR SAFETY: Installation and Operating Data Installation and Operation Manual Stealth Series Pumps Models SHPF and SHPM FOR YOUR SAFETY: This product must be in stalled and serviced by a professional service technician,

More information

OWNER S MANUAL Spa & Jetted Bathtub Pump

OWNER S MANUAL Spa & Jetted Bathtub Pump OWNER S MANUAL Spa & Jetted Bathtub Pump READ THIS MANUAL CAREFULLY BEFORE USING THE SPECK PUMP Important Notice: This manual contains important information about the installation, operation and safe use

More information

Installation and Operations Manual

Installation and Operations Manual Excalibur Water Systems 3.0 High Capacity Superflow Series QUADPLEX Water Softener Installation and Operations Manual 142 Commerce Park Drive, Units M-O, Barrie ON L4N 8W8 www.excaliburwater.com Water

More information

Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, P/N: , Revision 1

Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, P/N: , Revision 1 Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, P/N: 107065-01, Revision 1 March 03, 2017 Contents Introduction 2 Installation Pre-installation 3 Installation Procedure 4 Electrical

More information

TECHNICAL BROCHURE BSPDDRIVE. Aquavar SPD (Single Pump Drive) SIMPLEX VARIABLE SPEED PUMP CONTROLLER FOR SUBMERSIBLE AND CENTRIFUGAL PUMPS

TECHNICAL BROCHURE BSPDDRIVE. Aquavar SPD (Single Pump Drive) SIMPLEX VARIABLE SPEED PUMP CONTROLLER FOR SUBMERSIBLE AND CENTRIFUGAL PUMPS TECHNICAL BROCHURE BSPDDRIVE C U L US Aquavar SPD (Single Pump Drive) SIMPLEX VARIABLE SPEED PUMP CONTROLLER FOR SUBMERSIBLE AND CENTRIFUGAL PUMPS Aquavar SPD variable speed, constant pressure pump controller

More information

IMPORTANT SAFETY INSTRUCTIONS. READ, FOLLOW AND SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS. READ, FOLLOW AND SAVE THESE INSTRUCTIONS INTELLIFLO VSF VARIABLE SPEED AND FLOW PUMP OPERATING MANUAL 5PXF-VSF WFL-VSF IMPORTANT SAFETY INSTRUCTIONS. READ, FOLLOW AND SAVE THESE INSTRUCTIONS AQUATIC SYSTEMS P-INSB-VSF (REV. OCTOBER 2017) INTRODUCTION

More information

SUPERFLO VS VARIABLE SPEED PUMP

SUPERFLO VS VARIABLE SPEED PUMP SUPERFLO VS VARIABLE SPEED PUMP INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS i CUSTOMER SERVICE / TECHNICAL SUPPORT If you have questions

More information

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14 SEWAGE PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1261-0001 Español p. 14 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing parts?

More information

Dry Vacuum System. Part Numbers: V15, 2V15, 3V15 and 4V15 USER S MANUAL. Recommend Daily use of Monarch CleanStream

Dry Vacuum System. Part Numbers: V15, 2V15, 3V15 and 4V15 USER S MANUAL. Recommend Daily use of Monarch CleanStream Dry Vacuum System Part Numbers: V15, 2V15, 3V15 and 4V15 USER S MANUAL Recommend Daily use of Monarch CleanStream TABLE OF CONTENTS Description Page Congratulations...3 Purpose of this Manual....3 Safety

More information

SCE Qualified Variable Speed Pool Pump and Motor - Products List Last Updated: 08/14/2017 Manufacturer Make Model Number Advantage Pools and Ponds

SCE Qualified Variable Speed Pool Pump and Motor - Products List Last Updated: 08/14/2017 Manufacturer Make Model Number Advantage Pools and Ponds Advantage Pools and Ponds Advantage Quietflo Variable Speed Pump Quietflo Variable Speed Advantage Champion Variable Speed Pump Champion Variable Speed Advantage Manufacturing Advantage Manufacturing Energy

More information

Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions

Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions 600 S 56 th Street #9 Chandler, AZ 85226 Phone: 480-507-6478 Fax: 480-838-2232

More information

OWNER S MANUAL Model: TR-40-EX ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly)

OWNER S MANUAL Model: TR-40-EX ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly) OWNER S MANUAL Model: TR-40-EX (5301338) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly) Technical Specifications 40 Gal. Corrosion-Resistant Polyethylene Tank 12 Volt Diaphragm Pump,

More information

Matala. VersiFlow Series. Instruction and Maintenance Manual

Matala. VersiFlow Series. Instruction and Maintenance Manual VersiFlow Series High Flow Multi-Purpose "Versatile " Pump V-3200 1/5HP 150W / Discharge 2 V-3900 1/3HP 250W / Discharge 2 V-4700 1/2HP 400W / Discharge 2 V-5600 1HP 750W / Discharge 2 Instruction and

More information

Load Sensing Module Specification and Instruction Guide

Load Sensing Module Specification and Instruction Guide Load Sensing Module Specification and Instruction Guide To ensure proper protection against drowning due to full body entrapment on suction inlets (drains), follow these instructions for proper installation,

More information

Pool Skimmers and Skim Filters / Renegade Gunite In-Ground Skimmers IMPROVED SNAP LOCK-DOWN BASKET HANDLE! Skimmers / Skim Filters

Pool Skimmers and Skim Filters / Renegade Gunite In-Ground Skimmers IMPROVED SNAP LOCK-DOWN BASKET HANDLE! Skimmers / Skim Filters NSF Approved with Flow Rate of 75 GPM PVC sockets for better glue joints 2" socket is 2 1/2" spigot for more flow 1 1/2" socket is 2" spigot for easier plumbing 1/2" socket for overflow hose Large locking

More information

LX-80 COMMERCIAL POOL & SPA CONTROL INSTALLATION INSTRUCTIONS

LX-80 COMMERCIAL POOL & SPA CONTROL INSTALLATION INSTRUCTIONS LX-80 COMMERCIAL POOL & SPA CONTROL INSTALLATION INSTRUCTIONS IMPORTANT SAFETY PRECAUTIONS: All wiring must be performed by a qualified electrician. Basic safety precautions and local codes should be observed

More information

MagicStream Laminar. Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

MagicStream Laminar. Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS 1 MagicStream Laminar Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS 2 IMPORTANT SAFETY PRECAUTIONS Important Notice: Attention Installer:

More information

MODEL 422 Submersible Pump Controller

MODEL 422 Submersible Pump Controller MODEL 422 Submersible Pump Controller Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or 240VAC, Single-phase or 3-phase Built-in Trip and

More information

READ THIS MANUAL CAREFULLY BEFORE USING THE SPECK PUMP

READ THIS MANUAL CAREFULLY BEFORE USING THE SPECK PUMP OWNER S MANUAL Spa & Jetted Bathtub Pump READ THIS MANUAL CAREFULLY BEFORE USING THE SPECK PUMP Important Notice: This manual contains important information about the installation, operation and safe use

More information

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS EmerGen Switch Manual Transfer Switch OWNER S MANUAL AND INSTALLATION INSTRUCTIONS For A Series Models 6-5001, 6-7501, 10-7501, 10-12K1 PLEASE READ THIS MANUAL IN ITS ENTIRETY BEFORE INSTALLING AND/OR

More information

PRESSURE BOOSTER 150

PRESSURE BOOSTER 150 PRESSURE BOOSTER 150 Owners Manual! WARNING This equipment must be installed and serviced by a qualified technician. Improper installation can create electrical hazards which could result in property damage,

More information

ProLogic /AquaLogic. Troubleshooting Guide Residential. TSG-PL447b. Copyright 2016 Hayward Industries Inc.

ProLogic /AquaLogic. Troubleshooting Guide Residential. TSG-PL447b. Copyright 2016 Hayward Industries Inc. ProLogic /AquaLogic Troubleshooting Guide Residential TSG-PL447b Copyright 2016 Hayward Industries Inc. Safety Precautions Warning! High Voltage Electrocution Hazard Hazardous voltage can shock, burn,

More information

AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start)

AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start) AQUASTAR C6 (Comfort 6000) Next Generation Auto Backwash Valve System (selectable time-pressure or remote cycle start) SIDE MOUNTED AND TOP MOUNTED VALVES WITH QUICK INSTALL ELECTRIC ACTUATORS FOR PIPE

More information

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation M T E C o r p o r a t i o n MATRIX FILTER SERIES B 380-415 Volts, 50HZ USER MANUAL PART NO. INSTR - 015 REL. 060628 2006 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter

More information

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL MODEL #VP05, VP10 C US NSF/ANSI 372 255405 For loose, missing or damaged parts, or if the unit does not seem to be operating properly, please call before returning

More information

PAGE Both power cords must be connected & powered to operate the E-TES SD 120 volt unit.

PAGE Both power cords must be connected & powered to operate the E-TES SD 120 volt unit. PAGE 1 This document outlines questions to ask and components to check during E-TES SD 120 volt troubleshooting. More detailed troubleshooting procedures are available in the E-TES SD 120 volt Troubleshooting

More information

3 year warranty. (1) Treo Micro fiberglass, gunite fitting, 3/4 PVC. FLED-TM-W-PK10 (10) Treo Micros (WHITE) 80 NEW! Treo Micro fitting adapter

3 year warranty. (1) Treo Micro fiberglass, gunite fitting, 3/4 PVC. FLED-TM-W-PK10 (10) Treo Micros (WHITE) 80 NEW! Treo Micro fitting adapter pool lighting The Treo Micro LED light is 12VAC, 2 Watt LED underwater light designed for accent Available in lengths of 30, 50, 80', 150 50,000 hour lamp life No Earth bonding required White or color

More information

ESE Series Cast Iron Sewage Pumps

ESE Series Cast Iron Sewage Pumps Owner s Manual ESE Series Cast Iron Sewage Pumps TABLE OF CONTENTS General Safety.................... 2 Specifications..................... 3 Installation.................... 4 & 5 Troubleshooting...................

More information

Installation, Operating, and Service Manual. Badu. EcoM3 V. Variable Speed Pool Pump

Installation, Operating, and Service Manual. Badu. EcoM3 V. Variable Speed Pool Pump Installation, Operating, and Service Manual Badu EcoM3 V Variable Speed Pool Pump Technical Support: Address: Speck Pumps 8125 Bayberry Road Jacksonville, FL. 32256 USA Hours: (Monday - Friday) 8:00 am

More information