1 Dip Tester Model DS-03 -INSTRUCTION MANUAL- MALCOMTECH INTERNATIONAL INDUSTRIAL BLVD. HAYWARD, CA USA TEL. (510) FAX. (510)

2 TABLE OF CONTENTS I. INTRODUCTION TO THE DS-03 DIP TESTER 1. Overview Features... 3 Specifications... a. Measuring Data Specifications... b. General Specifications Dimensions Name of Units and their functions... a. Control Panel... 5 b. Sensors... 8 II. HANDLING 1. Normal Mode... a. Cleaning Sensors... b. Setting Upper Limits for Solder and Flux... c. Setting Width for Mounting Plate... d. Measuring... e. Reading Data After Measuring... III. MAINTENANCE AND 1. Replacing Battery Altering Flux Dry Resistance Checking Accuracy Repair and Calibration... IV. WARRANTY 1. Warranty...

3 I. INTRODUCTION TO THE DS-03 DIP TESTER 1. Overview Model DS-03 Dip Tester is a special purpose tester to stabilize and uniform the soldering performance of automatic soldering systems. Formerly, soldering temperature, preheater temperature and dip time of a soldering system to serve as the reference data were individually measured using specially devised measuring instruments. With these measuring instruments, it was difficult to measure individual data under constant conditions and simultaneously. Quite often, the measurement values were different from the actual values of printed circuit boards as they showed while running through the automatic soldering line. This system solves the above problems by feeding printed circuit boards in the same way as you put them on an automatic soldering line and reading various data on soldering performance in one stroke at the end of a circuit of the automatic soldering process. Since these data are simultaneously measured, conditions of the soldering systems are consistent and thus reliable, and can be used as reference data for uniform and stable soldering. The DS-03 measures dual-tank type soldering systems which cannot be measured with the conventional models DS-01 and DS-02. The DS-03 covers Model DS-02 in terms of function. Major features are described as follows.

4 2. FEATURES The DS-03 features the same performance as that of conventional DS-01 and DS-02, and measures soldering temperature and dip time, respectively, of dual tank type soldering systems. a) Soldering temperature of the 1st soldering tank. b) Soldering temperature of the 2nd soldering tank. c) Dip time of the 1st soldering tank. d) Dip time of the 2nd soldering tank. e) Total dip time for the 1st and 2nd soldering tank. f) Temperature on the underside of the board by preheaters (preheater temperature) g) Confirmation of flux dryness by preheater. h) Confirmation of upper limit of flux height. I) Confirmation of upper limit of solder height. NOTE: In the case of a single-tank soldering system, soldering temperature and dip time are displayed for the 1st tank, and 000 is displayed for the 2nd tank. The control panel is flat and a microcomputer is incorporated to improve operability. Measurement data are retained until power is shut OFF. The battery has a longer life because of the setting of lower power consumption. Measurement results can be printed and stored by using an optional printer adapter.

5 3. SPECIFICATIONS a. Measurement Data Specifications Soldering Temperature Item Sensor Display Method Measuring Range Temperature on the underside of board CA Sheath CA Thermocouple LCD Digital 3-Digit 0 to 300 C ± 2 C 50 to 300 C ± 2 C Accuracy/ Contents Dip Time Electrode 0 to 10.0 sec. ±0.2 sec. Flux Dryness Electrode (resistance) Red LED lights when each item is defective 10kΩ to 5mΩ Flux Height Electrode Green LED lights With reference when all are to underside of acceptable board 0 6mm Solder Height Electrode 2 φ electrode intervals of 4mm Scale resolution 1mm b. General Specifications Item Contents Cold Contact Point Compensation Automatic compensation with platinum temperature measuring resistor. Ambient Temperature 5 minutes or less OK at ambient 120 C Battery Usable Time Life of Sensor Mounting Plate Dimensions Weight S-006 9VDC, 1 piece More than 10 continuous hours More than 5,000 times at soldering temperature 250 C and dip time 5 sec. 94mm x 230mm x 51mm 840g (without battery)

6 4. DIMENSIONS (Unit: mm)

7 5. PART NAMES AND FUNCTIONS a. Control Panel Figure 2

8 (1) POWER ON SWITCH Power is supplied when switch is pressed. Version statement appears for about 3 seconds, and then the system is ready to start. (2) POWER OFF SWITCH Power is shut OFF when switch is pressed. On turning OFF the system, the internal memory is reset to erase measurement results. (3) HOLD SWITCH This is not used in normal measurements. Your system will not measure temperature of soldering tank and dip time unless the preheater temperature reaches 50 C. When the preheater temperature does not reach 50 C, you may press this switch and then feed the items to the line. With this, you can measure solder temperature and dip time even when the preheater temperature is low. This function is released when power is turned OFF. (4) SELECT SWITCH This is the switch to select the display for measurement data. Press and release the switch after measuring, and the lamps light and the display data are switched as shown in the table below. For double-tank soldering systems ( : lit -: extinguished) Order Display (9) Heater Lamp 1 Preheater Temperature 2 Primary Solder Temperature 3 Secondary Solder Temperature 4 Primary Dip Time 5 Secondary Dip Time (10) Solder Lamp (11) Dip Time Lamp (12) Dip 1 Lamp (13) Dip 2 Lamp 6 Total Dip Time

9 (5) FLUX WET LAMP The flux coated on boards is dried by preheaters, and then enters the soldering tank. If it is not fully dry, soldering can be unsatisfactory. Accordingly, dryness of the flux by preheaters is shocked with the flux dryness sensor (h) immediately before it enters the soldering tank. If the flux is not dry, the lamp lights up. (6) FLUX LEVEL LAMP If the flux level is too high, the flux may spill to the board. The flux level sensor (g) is used to set the upper limit for the flux level. If the flux is applied above the preset height, the flux level lamp lights up to indicate the flux leel is too high. The lamp is retained until power is shut OFF. (7) SOLDER LEVEL LAMP Like the flux level, the upper limit for the soldering solution level is set by the solder level sensor. The sensor monitors the level of the soldering solution. When the level becomes too high, the solder level lamp lights up. The lamp is retained until power is shut OFF. (8) OK LAMP After measurement, OK lamp goes when flux dryness, flux level and solder level were normal to indicate that there were no abnormal measurements. (9) HEATER LAMP The lighting heater lamp indicates that the figures on display are preheater temperatures. Immediately after making power, heater lamp goes on and preheater temperatures are displayed. (10) SOLDER LAMP The lighting solder lamp indicates that the figures on display are the first or second solder temperature. The primary and secondary solder temperature are identified by (12) First Dip Lamp and (13) Second Dip Lamp. On making power, 000 will be displayed in place of temperature even if you try to display solder temperature with (4) Select Switch when no measurements have been made. For a single-solder tank, the lamp goes on as if the secondary solder temperature were displayed, but actually, the secondary solder temperature is displayed as 000.

10 (11) DIP TIME LAMP The lighting dip time lamp indicates that the figures on display are dip time. Primary dip time is displayed when (12) First Dip Lamp is lit; secondary dip time when (13) Second Dip Lamp is lit; and total dip time when both lamps are lit. (12) FIRST DIP LAMP The lighting lamp indicates that the primary solder temperature or dip time is shown. (13) SECOND DIP LAMP The lighting lamp indicates that the secondary solder temperature or dip time is shown. (14) LCD DISPLAY The LCD display show various measurement, temperature and dip time. The LCD display goes off and OVER mark is shown in the lower left hand corner of the LCD when the battery is low; battery voltage dropped; and it is time to replace the battery.

11 b. Sensors Figure 3

12 (a) DIP TIME SENSOR This is the electrode to detect dip time in the solder tank. (b) FLUX WET SENSOR This is the sensor to detect dryness of flux located between these two electrodes as electri resistance. (Resistance varies with the flux to use. See II-3.b for details). (c) PREHEATER TEMPERATURE SENSOR This is the CA thermocouple to detect the temperature on the underside of boards heated by preheaters. (d) SOLDER TEMPERATURE SENSOR This is the CA sheath thermocouple to detect solder temperature. It is mad of soft material. Do not have it caught, drop, change the shape, or bend.. (e) SOLDER LEVEL SENSOR This is the electrode to detect the highest solder level. (See II-1.b) for instructions. (f) SOLDER LEVEL INDICATOR This indicates the height to set the upper limit for the solder level. (g) SOLDER LEVEL SENSOR FIXING SCREW This screw is loosened when setting the upper limit for solder level. The sensor is fixed when measuring. (h) FLUX LEVEL SENSOR This is the electrode to detect the highest flux level. (See II-1.b) for instructions. (i) FLUX LEVEL SENSOR FIXING SCREW This indicates the height to set the upper limit for the solder level. (j) FLUX LEVEL SENSOR FIXING SCREW This screw is loosened when setting the upper limit for solder level. It is tightened to fix the sensor when measuring.

13 (k) F.S. DIAL If you see indicators (f) and (I) are at the lowest position on the scale, you can assume that the sensors for the flux and solder levels are in the same position as the underside of the printed circuit boards. The scale is graduated in 1mm intervals.

14 II HANDLING Model DS-03 measures soldering systems in the same way as conventional Models DS-01 and DS-02, and also partly confirms electrical setting conditions. The former is called normal mode (ordinary measuring mode), and the latter user mode. Both modes are described below. 1. Normal Mode a. Cleaning Sensors Before measuring, always clean sensors with alcohol (IPA). It is particularly important to fully remove flux from sensors for flux level, solder level, dip time and flux dryness. Do not have the solder temperature sensor caught in the cleaning cloth and deform it: the sensor does not have enough strength. b. Setting Upper Limit for Solder and Flux Before starting measurement, the upper limit for solder and flux is set. This is necessary to use the function of I-5, (6) and (7). The upper limit varies with your soldering system and printed circuit boards fed to the production line. It must be adequately set by individual customers. Setting method is as follows: (1) Loosen screws g and j in Figure 3. (2) Move sensors e and h to the position where the conditions are met [while watching indicators f and I. (3) Fix sensors e and h by tightening screws g and j. c. Setting Width for Mounting Plate This system must be installed on the conveyor carriers or conveyor claws of your soldering system when using the system for measurement. The system is provided with two mounting plates as mounting fixtures. Install the mounting plates to the underside of the main unit with knurled screws (two on each side). Each plate is adjustable about 15mm sideways. Adjust them to the width of your soldering system. Be sure to fully tighten the screws. If they are loose, they may drop in the machine and damage it. Mounting procedures are shown in Figure 4.

15 Mounting holes on the underside of dip Figure 4 4) MEASUREMENT 1. Press POWER ON SWITCH to make power. On making power, LCD s other than BATT go on, and V0.3 (Version No.) appears. The display lasts about three seconds, and the system is ready to start. 2. Be sure HEATER lamp is lit, and a temperature closed to room temperature is shown. If a temperature much higher than room temperature (by 5 C or more) is shown, turn the system OFF, and cool it OFF (to approximately 25 C). Turn the system ON. NOTE: If you see OVER display, take necessary action by referring to III Be sure you have already adjusted the mounting width of the system in the steps shown in II-1.c. Install the unit on the carrier of the conveyor. For a unit without carriers, fix the system by hooking plates on the claws on the conveyor. Note that if the system is loose and moves, stable data measurement is not possible. 4. When the soldering operation ends, the system is lifted and the measurement ends. Be sure not to turn power OFF. If you turn power OFF on ending the operation, the data are erased. WARNING!!! BE CAREFUL OF GETTING BURNED BECAUSE THE SYSTEM IS HOT WHEN LIFTING IT!!

16 5) Reading Data After Measuring a. To protect the sensors, place the unit with the handle on the top lifted. b. If flux dryness, flux level or solder level is abnormal, lamps (5), (6), and (7), Figure 2, lights up, respectively. If all data are normal, green lamp (8), Figure 2, light up. c. Press Select Switch (4), Figure 2. Measurement temperature and dip time are displayed in the order shown below. (Switch one time) PREHEATER TEMPERATURE PRIMARY SOLDER TEMPERATURE SECONDARY SOLDER TEMPERATURE PRIMARY DIP TIME SECONDARY DIP TIME PRIMARY DIP TIME The lamp indicates what measurement values the data on display are: ( : lit -: extinguished) Order Display (9) Heater Lamp 1 Preheater Temperature 2 Primary Solder Temperature 3 Secondary Solder Temperature 4 Primary Dip Time 5 Secondary Dip Time (10) Solder Lamp (11) Dip Time Lamp (12) Dip 1 Lamp (13) Dip 2 Lamp 6 Total Dip Time

17 NOTE: When measuring in a single-tank soldering system, the secondary solder temperature and dip time are displayed as 000 or The total dip time is the same value as primary dip time. 4). To print the measurement results, set the system to the optional printer before shutting OFF power for the system after measurement. 5) After having recorded the results of measurement, press POWER OFF switch, turn power OFF, and cool down the system to room temperature. 2. Activating User Mode As mentioned before, the electrical setting of DS-03 main unit can be partly confirmed in the user mode, in addition to the functions of conventional dip testers. a) Turn power OFF. b) Press POWER On switch while pressing HOLD switch (3), Figure 2, to turn power ON. c) The display read V0.3 does not appear, try again. d) The version statement goes off in about 5 seconds. HEATER lamps are lit, and preheater temperature are displayed. e) The display changes each time you press SELECT switch.

18 PREHEATER TEMPERATURE (HEATER lamp lights) SOLDER TEMPERATURE (SOLDER lamp lights) DS-03 INTERNAL TEMPERATURE (No lamp lights) FLUX DRYNESS RESISTANCE (FLUX WET lamp lights) NOTE: Preheater and solder temperature are not measurement values but the current temperatures of preheater and solder temperature sensors. Touch the solder temperature sensor with your finger, and you can confirm the temperature change. NOTE: Flux dryness resistance is described briefly in II-3.b, you need only to confirm the values at this stage.

19 3) What you should know This section describes the items which have not been mentioned in the previous sections. a. Function of DS-03 during measurement (in normal mode) (1) On making power, the version statement appears for approximately 3 seconds. The system is then ready for measurement. Preheater temperature are displayed. (2) Install the system on your soldering system. On reaching the fluxer and coating flux, FLUX LEVEL lamp lights up when the flux attaches to FLUX LEVEL sensor which has been set. (3) The sensor board is heated by the preheater and the preheater temperature rises. If the preheater temperature is below 50 C, solder temperature will not be measured after plunging into the solder tank. (4) Having passed through the preheaters, the maximum temperature received from the preheaters is held and stored. (5) On plunging into the first solder tank, the dip sensor on the sensor board is electrically shorted, and detects that the subject has plunged into the first solder tank. FLUX WET lamp lights up when FLUX WET sensor detects a resistance value lower than the preset flux dryness resistance. (6) The solder temperature sensor starts measurement when the dip sensor (4) was electrically shorted. Note that no measurement will be made even when the dip sensor was shorted if the preheater sensor is still below 50 C at this time. Further, when you pressed HOLD button before measurement, the system starts measuring solder temperature as soon as the dip sensor is shorted even if the preheater temperature is below 50 C. (7) SOLDER LEVEL lamp goes on when the solder liquid level touches the SOLDER LEVEL sensor while passing through the solder tank. (8) Measurement of the solder temperature of the first solder tank is completed when the dip sensor is electrically released on leaving the first solder tank. (9) Like the first tank, plunge into the second solder tank is detected when electric short of the dip sensor is detected. (10) Measurement of the solder temperature of the second tank starts with the detection of the plunge of the second tank. Passage is confirmed on detecting electrical release of the dip sensor. Measurement of the solder temperature of the second tank is completed at this time.

20 (11) Dip time is a time period from when the dip sensor plunged into the solder tank and electrically shorted to when it is released. (12) OK lamp goes on immediately after passing the first solder tank when the preset conditions were met. When there is trouble in the second solder tank OK lamp goes off and TROUBLE lamp goes on instead. b. Detecting Flux Dry Resistance Dry flux has a high resistance. When it is not dry, the resistance decreases. A guideline on the dryness of flux can be established by comparing the resistance of flux with a reference resistance. Since dry resistance varies with the type of flux, a single common resistance for all types of flux cannot be used with DS-03. Several resistance value is adjustable according to the type of flux you use. To change the value, refer to III MΩ 0.10MΩ 0.22MΩ 0.50MΩ 1.00MΩ 2.20MΩ 5.00MΩ You can check the flux dryness resistance with user mode. The unit is MΩ. Your system has been set to 0.22MΩ at the factory.

21 III MAINTENANCE AND WARRANTY SERVICE 1. Replacing Battery When you see OVER message in the lower left-hand corner of the LCD display, it is time to replace the battery. Replace it in the steps below: (1) Press POWER OFF to turn power OFF. (2) Remove the battery cover by removing two screws at the bottom of the main body. (3) Pull out the old battery and replace (006P, 9V, 1 piece). Be sure of polarity of the battery. If the battery is placed wrongly and left as it is for a long time, the battery may be damaged or system failure may result. (4) Replace the cover as shown and fix it with the screws. A failure may result in the cover is mounted inside out. (5) Press POWER ON switch to run the system on. Be sure the system operates correctly, and OVER is not shown. If BATT appears on the display, the battery is old. Replace it with a new one. If nothing is displayed on making power, the battery polarity is reversed. Replace the battery to the correct polarity. NOTE: Measurement data are not affected even if OVER appears while in the measurement (running in the line). Replace the battery as soon as possible. Figure 5

22 2. Changing Flux Dry Resistance Dry resistance of flux can be varied. The following resistance values are available for detection with the DS-03. The steps to change the values are as described below: 0.01MΩ 0.10MΩ 0.22MΩ 0.50MΩ 1.00MΩ 2.20MΩ 5.00MΩ NOTE: Your system has been set to 0.22MΩ at the factory. (1) Shut OFF power with POWER OFF switch. (2) Remove the battery cover referring to II-1 Replacing the Battery. (3) Pull out the battery. (4) Locate a small switch on the side of the battery case. Slide the switch knob away from you. (5) Replace the battery and the cover. (6) Turn power ON. Current resistance is displayed. (7) The resistance value changes each time you press and release SELECT switch. (8) Continue to press and release SELECT switch until the desired value appears. With the value on display, press HOLD switch. The value is stored. (9) Turn power OFF. Remove the cover and the battery. Reset the switch know to original position. (10) Replace the battery and the cover. (11) Turn the power ON. Check that the system operates normally. If not, re-check polarity of the battery and the position of the switch.

23 3. Checking Accuracy For correct measurement, the system must operate normally, and the performance must be maintained in good condition. Check accuracy of the system periodically, and calibrate if the performance shows difference. Accuracy is maintained for a long time if the system is checked for accuracy once every 6 months by the user, in addition to the yearly calibration. Steps for accuracy confirmation are described below. Preparation: - Calibration CA sensor (optional) - Standard glass thermometer - Boiling water - Water of ordinary temperature (1) Turn power OFF. (2) Remove the terminal cover on the sensor plane by removing two screws. (3) Remove the solder temperature sensor, and install the calibration CA sensor. (4) Put the calibration CA sensor and the standard glass thermometer in the boiling water. (5) Press POWER ON SWITCH while pressing HOLD switch to activate the user mode. Select solder temperature (See II-2.a). (6) Check that the difference between the temperature on the LCD and the reading of the glass thermometer is within ±2 C. (7) Put the calibration CA sensor and the standard glass thermometer in the water of ordinary temperature. Like (6) above, check that the difference between the temperature on the LCD and the reading of the glass thermometer is within ±2 C. (8) Turn power OFF. (9) Remove the calibration CA sensor from the main unit, and replace the solder temperature sensor.

24

25 4. Repair & Calibration Should you experience any difficulties in operating DS-03, and/or calibration is required, please contact your Malcom dealer or Malcom Instruments Corporation for assistance. IMPORTANT!! DO NOT ATTEMPT TO DISASSEMBLE OR SERVICE THE EQUIPMENT YOURSELF!! MALCOMTECH INTERNATIONAL Industrial Blvd. Hayward, CA U.S.A. Tel. (510) Fax. (510) Web. IV. WARRANTY Malcom Company Limited warrants this equipment against defects in parts and workmanship for one full year from date of purchase. The company will, at its own discretion, repair or replace any defective parts, which the company, upon inspection shall determine to be defective in material and/or workmanship. This is provided that the unit is returned, in safe proper packing, to the dealer or manufacturer. The following will void the warranty: - improper installation, abuse, misuse or misapplication, use beyond specifications, namely prolonged exposure to high temperatures, improper storage, damage caused from accidents, damages caused by improper packing. Malcom shall not be held responsible for damage caused from: natural and man-made disasters, pollution, improper operating environment, abnormal voltages or transient power surges.

26 MALCOMTECH INTERNATIONAL Industrial Boulevard Hayward, CA Tel. (510) Fax. (510) MANUFACTURERS SPIRAL VISCOSITY MEASUREMENT DE- VICES SOLDERING PROCESS CONTROL DEVICES SERVICE Thank you for purchasing this Malcom product. It was manufactured using the highest quality components and was meticulously adjusted and calibrated to factory specifications. We hope that it will provide you with many years of trouble-free operation. Should you encounter difficulty in using your instrument, or if it s performance has become abnormal, please consult the troubleshooting section of your operation manual. Should this not enable you to solve the problem, do not attempt to dissemble, lubricate or repair the unit yourself, doing so will void the warranty. Instead, contact Malcom Instruments directly at: Tel. (510) Fax. (510) service@malcomtech.com Quite often it is possible to resolve problems over the phone. If the difficulty is such that it requires the return of the product for repair, please secure the instrument with the supplied shipping brackets and place it into its original packing. If this is not possible, use a strong tape or cord to secure the unit for shipping. Pack the device in a rugged box much larger than the actual instrument. Use plenty of packing material that is elastic, such as bubble wrap. Styrofoam, etc. Do not use material such as newspaper, popcorn or wood shavings. Damages caused by shipping is not covered by the warranty. Send the unit, postage prepaid and insured, to the address given below. Warranty The warranty for your Malcom product is six (6) months parts, and three (3) months labor. To guarantee in-warranty service, please fill out the below sheet and return to: Malcomtech International, Industrial Blvd., Hayward, CA Your time in this matter is greatly appreciated. . service@malcomtech.com Model: Serial Number: cut on this line Model: Serial: Purchase Date: Company: Name of Owner/Operator: Tel. ( ) Company Address: City/State/Zip: NOTE: NO WARRANTY WILL BE HONORED WITHOUT THIS FORM ON FILE AT MALCOM.

MALCOM Table-Top Digital Viscometer Model PC-1TL Series

MALCOM Table-Top Digital Viscometer Model PC-1TL Series MALCOM Table-Top Digital Viscometer Model PC-1TL Series INSTRUCTION MANUAL MALCOMTECH INTERNATIONAL 26200 INDUSTRIAL BLVD. HAYWARD, CA 94545 USA TEL. (510) 293-0580 FAX. (510) 293-0940 WEB. www.malcomtech.com

More information

Operation Manual MODEL EC331. Microcomputer Based Conductivity /Resistivity & Temperature Pocket Meter EC331

Operation Manual MODEL EC331. Microcomputer Based Conductivity /Resistivity & Temperature Pocket Meter EC331 Operation Manual MODEL EC331 Microcomputer Based Conductivity /Resistivity & Temperature Pocket Meter EC331 CONTENTS INITIAL INSPECTION AND ASSEMBLY...2 VISIONPLUS EC331 OVERVIEW...2 A. Meter Description...2

More information

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases Blue Air Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases Please read this manual completely before installing or operating this unit! BACB53 BACB71 BACB74 BACB83 BACB86 BACB96

More information

instructions ZCM ZCM START International 4270 Airborn Dr. Addison, TX 75001, USA Tel Fax

instructions ZCM ZCM START International 4270 Airborn Dr. Addison, TX 75001, USA Tel Fax ZCM 1000 START International 4270 Airborn Dr. Addison, TX 75001, USA Tel 972.248.1999 Fax 972.248.1991 TM START Japan Corporation 1-26-14 Toshin-Cho Itabashi-ku Tokyo, Japan Tel 81.3.3554.5608 instructions

More information

Megohmmeter Test Probe

Megohmmeter Test Probe Megohmmeter Test Probe User Manual ENGLISH www.aemc.com CHAUVIN ARNOUX GROUP Copyright Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All rights reserved. No part of this documentation may be reproduced

More information

EC1 Pocket Conductivity Tester Instruction Manual

EC1 Pocket Conductivity Tester Instruction Manual EC1 Pocket Conductivity Tester Instruction Manual OAKTON INSTRUMENTS www.4oakton.com v2.2 EC1 Pocket Conductivity Tester Instruction Manual 1. Battery Installation Please install batteries according to

More information

Table of Contents Title Page No.

Table of Contents Title Page No. Table of Contents Title Page No. INTRODUCTION 1 SAFETY PRECAUTIONS / WARNINGS 2 CONTROLS AND INDICATORS 4 PREPARATION AND CAUTION BEFORE USE 5 TESTING PROCEDURES 6 A. AC/DC VOLTAGE MEASUREMENT 6 B. RESISTANCE

More information

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

Reach ins, Freeezers & Refrigerators Installation & Operation Manual Reach ins, Freeezers & Refrigerators Installation & Operation Manual BSR23 BSF23 BSR49 BSF49 BSR72 BSF72 IMPORTANT SAFETY INSTRUCTIONS (SAVE THESE INSTRUCTIONS) Visit us on the web at www.blueairinc.com

More information

INTRODUCTION. Backlight for operating in dark area Low battery indicator Auto power off function. CO levels and its effect

INTRODUCTION. Backlight for operating in dark area Low battery indicator Auto power off function. CO levels and its effect INTRODUCTION Congratulations on your purchase of this digital pen type CO meter. Please read the manual completely before using the meter. Features: Adjustable CO warning level Dual and digital display

More information

Installation & Operation Manual Chef Base

Installation & Operation Manual Chef Base Installation & Operation Manual Chef Base Please read this manual completely before installing or operating this unit! BACB53 BACB53M BACB71 BACB71M BACB74 BACB74M BACB83 BACB83M BACB86 BACB86M BACB96

More information

3-in-1 Electric Jack, Impact Wrench & Air Compressor

3-in-1 Electric Jack, Impact Wrench & Air Compressor Item No. : 7010 3-in-1 Electric Jack, Impact Wrench & Air Compressor User s Manual We are constantly improving our products so specifications are subject to change without notice. Visit our website for

More information

IMPORTANT RECEIVING INSTRUCTIONS:

IMPORTANT RECEIVING INSTRUCTIONS: Gardner Bender Instruction Sheet B2000 Cyclone Bender Serial Numbers Begining With E IMPORTANT RECEIVING INSTRUCTIONS: Visually inspect all components for shipping damage. If any shipping damage is found,

More information

FD Conveyor for FD 260 Tabber

FD Conveyor for FD 260 Tabber FD 260-20 Conveyor for FD 260 Tabber Operator Manual 1/2011 First Edition TABLE OF CONTENTS 1. INTRODUCTION... 1 1.1 FD 260-20 DESCRIPTION... 1 1.2 ITEMS INCLUDED... 1 1.3 OPERATING MANUAL SAFETY TERMS...

More information

10A / 15A / 20A Solar Charge Controller. PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL

10A / 15A / 20A Solar Charge Controller. PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL 10A / 15A / 20A Solar Charge Controller PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL Dear Customer, Thank you very much for choosing our product. This manual contains important information about

More information

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev Manual Part #: M-3022 Feeder AF371 Operations Rev. 3-16-04 1 RENA AF371 Feeder YOUR RENA AF371 IS DISTRIBUTED BY RENA SYSTEMS INC. SERVICE AND SUPPORT FOR THIS PRODUCT IS PROVIDED BY YOUR RENA DEALER.

More information

Model 2500 Horsepower Computer System User Manual

Model 2500 Horsepower Computer System User Manual Model 2500 Horsepower Computer System User Manual Manufacturered by: Ries Labs, Inc. 2275 Raven Road Farina, IL 62838 Phone: (618) 238-1400 email: admin@rieslabs.com Table of Contents Description ----------------------------------------------------------------

More information

OPERATION AND MAINTENANCE

OPERATION AND MAINTENANCE Table of Contents GENERAL INFORMATION INTRODUCTION... 1 Operating Specifications... 1 FEATURES... 1 SAFETY PRECAUTIONS... 2 SET-UP... 2 OPERATION AND MAINTENANCE TESTING AN IGNITION MODULE OR IGNITION

More information

Gauge Adapter Instruction Manual

Gauge Adapter Instruction Manual Instruction Manual MODELS: CF3812, CF3812E, CF3814 & CF4514 CF3812-M1_092017! This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that

More information

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995 8 Light Controller With Light Timer 240 Volts Product #703008 Instruction Manual INNOVATING SINCE 1995 1 www.titancontrols.net 8 Light Controller This manual covers the following: Warnings & Cautions 8

More information

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator Blue Air Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator Please read this manual completely before installing or operating this unit! BAGR7 Blue Air reserves

More information

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual. Helios 14 24 Light 240 Volt Controller PRODUCT # 702832 Instruction Manual www.titancontrols.net Warnings & Cautions Helios 14 Lighting Controller Overview Instructions for Operation Troubleshooting Tips

More information

Instruction Manual AVTM for. Strip Chart Recorder Catalog Nos and

Instruction Manual AVTM for. Strip Chart Recorder Catalog Nos and AVTM220003 Rev. B January 2003 Instruction Manual AVTM220003 for DC µa Strip Chart Recorder Catalog Nos. 220003 and 220003-47 PO Box 9007 Valley Forge, PA 19485-1007 U.S.A. 610-676-8500 Shipping Address:

More information

8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5

8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5 \ 8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5 Marine Salt Testa Digital meter for the measurement of salinity, specific gravity and temperature Operation Manual 1. PRECAUTION The Marine Salt testa is for the sole

More information

will result in death or serious injury. could result in death or serious injury. Indicates a hazardous situation which, if not avoided,

will result in death or serious injury. could result in death or serious injury. Indicates a hazardous situation which, if not avoided, SAFETY SETUP OPERATION MAINTENANCE WARNING SYMBOLS AND DEFINITIONS This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this

More information

AC / 65 W M PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

AC / 65 W M PLEASE READ BEFORE OPERATING THIS EQUIPMENT. AC / 65 W M 5V AX 11 PLEASE READ BEFORE OPERATING THIS EQUIPMENT. TABLE OF CONTENTS 1 2-10 6-8 11 11 12 14-15 AC / 65 W M 5V AX 11 Included Items Operating Instructions Troubleshooting Guide Maintenance

More information

Solar Differential Temperature Controller Model DTC-D

Solar Differential Temperature Controller Model DTC-D OVERVIEW The DTC-D is specifically designed for solar heating applications where the collector circulation pump is powered from a solar (PV) panel, or optionally, battery power or any 12VDC source. Its

More information

Installation Instructions for: Channel Thermocouple Amplifier

Installation Instructions for: Channel Thermocouple Amplifier Installation Instructions for: 30-2204 4 Channel Thermocouple Amplifier WARNING: This installation is not fo r the electrically or mechanically challenged! Use this sensor with EXTREME caution! If you

More information

Manifold w/ Needle Valve Instruction Manual

Manifold w/ Needle Valve Instruction Manual MODELS: MFC2 & MFC4 Manifold w/ Needle Valve Instruction Manual SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153 Tel: 888-332-6419 - Fax: 816-448-2142 E-mail: sales@bvahydraulics.com Website: www.bvahydraulics.com

More information

Model 616 Rotating Disk Electrode Instruction Manual

Model 616 Rotating Disk Electrode Instruction Manual Model 616 Rotating Disk Electrode Instruction Manual 219303 C / 1202 Printed in USA Advanced Measurement Technology, Inc. a/k/a Princeton Applied Research, a subsidiary of AMETEK, Inc. WARRANTY Princeton

More information

Model P772 Conductivity Meter. User Manual

Model P772 Conductivity Meter. User Manual Model P772 Conductivity Meter User Manual 1 Table of Contents 1 INTRODUCTION... 1 2 SAFETY SUMMARY... 2 3 COMPLIANCE STATEMENTS... 2 4 PRODUCT CONTENTS AND INSPECTION... 3 5 DEVICE DESCRIPTION... 4 6 OPERATING

More information

RESOURCE GUIDE. P r o d u c t M a n u a l. START International

RESOURCE GUIDE. P r o d u c t M a n u a l. START International RESOURCE GUIDE P r o d u c t M a n u a l The information contained in this Resource Guide along with additional maintenance and repair information, videos and photos can be found online at www.startinternational.com

More information

EC20 Pocket Conductivity Tester Instruction Manual

EC20 Pocket Conductivity Tester Instruction Manual EC20 Pocket Conductivity Tester Instruction Manual APERA INSTRUMENTS, LLC www.aperainst.com EC20 Pocket Conductivity Tester Instruction Manual 1. Battery Installation Please install batteries according

More information

1 2 3a 3b THREADING CARD 9 10 ABC Office

1 2 3a 3b THREADING CARD 9 10 ABC Office 1 2 3a 3b 4 5 6 7 8 9 10 THREADING CARD Important Safety instructions YOUR SAFETY AS WELL AS THE SAFETY OF OTHERS IS IMPORTANT TO GBC. IN THIS INSTRUCTION MANUAL AND ON THE PRODUCT ARE IMPORTANT SAFETY

More information

PORTA-TRAC. Portable Flame Cutting Machine INSTALLATION AND OPERATION INSTRUCTIONS

PORTA-TRAC. Portable Flame Cutting Machine INSTALLATION AND OPERATION INSTRUCTIONS ADI 3046-B Certified ISO 9001 PORTA-TRAC Portable Flame Cutting Machine INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions Controls Corporation

More information

FUNNEL CAKE FRYER Instruction Manual Models: 8078 / FC-4, 8082 / FC-6, and 8090 / FC-4

FUNNEL CAKE FRYER Instruction Manual Models: 8078 / FC-4, 8082 / FC-6, and 8090 / FC-4 Part No. 89784 Revised: December 2005 FUNNEL CAKE FRYER Instruction Manual Models: 8078 / FC-4, 8082 / FC-6, and 8090 / FC-4 Cincinnati, OH 45241-4807 USA GAS SAFETY PRECAUTIONS INSTALLATION INSTRUCTIONS

More information

Model FMBC3000 Series Operating Instructions. Drum Pump Flow Meter

Model FMBC3000 Series Operating Instructions. Drum Pump Flow Meter Model FMBC3000 Series Operating Instructions Drum Pump Flow Meter Table of Contents Safety... 1 Introduction... 1 Specificatons... 1 Features... 1 Section 1 - Installation... 2 Section 2 - Operation...

More information

Time Electronics DC Multifunction Voltage/Current/Resistance Calibrator. Technical Manual

Time Electronics DC Multifunction Voltage/Current/Resistance Calibrator. Technical Manual Time Electronics 1017 DC Multifunction Voltage/Current/Resistance Calibrator Technical Manual V1.2 01/11/10 Time Electronics Ltd Botany Industrial Estate, Tonbridge, Kent, TN9 1RH Tel: +44(0)1732 355993

More information

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate. FEATURES Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate. Silicon diodes with inherent surge protection operated at a conservative percentage

More information

Cable Length Meter INSTRUCTION MANUAL

Cable Length Meter INSTRUCTION MANUAL CLM100 Cable Length Meter INSTRUCTION MANUAL ENGLISH 1-800-547-5740 www.ueitest.com email: info@ueitest.com TABLE OF CONTENT Introduction Features icludes Safety Tips International Symbol Instructions

More information

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

18VDC ESB6 Series Cordless Screwdrivers Operation Manual 18VDC ESB6 Series Cordless Screwdrivers Screwdriver Models : ESB6-8, ESB6-12, ESB6-15, ESB6-22 CAUTION - Please read, understand, and follow all operating and safety instructions in this manual before

More information

CRS1, CRS2 and CRS3. For additional information please call our. PRO CHARGING SYSTEMS, LLC 1551 Heil Quaker Boulevard, LaVergne, TN

CRS1, CRS2 and CRS3. For additional information please call our. PRO CHARGING SYSTEMS, LLC 1551 Heil Quaker Boulevard, LaVergne, TN CRS1, CRS2 and CRS3 For additional information please call our Technical Support Group 800.742.2740 PRO CHARGING SYSTEMS, LLC 1551 Heil Quaker Boulevard, LaVergne, TN 37086-3539 110310 Installation and

More information

Part No DROP IN POPCORN WARMERS Instruction Manual Model #2343, 2344, 2345

Part No DROP IN POPCORN WARMERS Instruction Manual Model #2343, 2344, 2345 Part No. 39406 DROP IN POPCORN WARMERS Instruction Manual Model #2343, 2344, 2345 SAFETY PRECAUTIONS 2 INSTALLATION INSTRUCTIONS Inspection of Shipment: Unpack all cartons and check thoroughly for any

More information

instruction ZCM 100 ZCM 200 START International 4270 Airborn Dr. Addison, TX 75001, USA Tel Fax

instruction ZCM 100 ZCM 200 START International 4270 Airborn Dr. Addison, TX 75001, USA Tel Fax ZCM 100 START International 4270 Airborn Dr. Addison, TX 75001, USA Tel 972.248.1999 Fax 972.248.1991 TM instruction ZCM 200 TM info@startinternational.com www.startinternational.com 10/07 Part Number

More information

Bio-Pump Plus. Operating Instructions. Product # ZBP-200. Description. Specifications

Bio-Pump Plus. Operating Instructions. Product # ZBP-200. Description. Specifications Bio-Pump Plus Product # ZBP-200 Operating Instructions Description The Bio-Pump Plus is an advanced portable, battery powered air sampling pump designed for the exclusive use with Air-O-Cell,Via-Cell,

More information

Digital/Analog Megohmmeter Model 1026 USER MANUAL

Digital/Analog Megohmmeter Model 1026 USER MANUAL Digital/Analog Megohmmeter Model 1026 USER MANUAL Limited Warranty The Megohmmeter Model 1026, is warranted to the owner for a period of 2 years from the date of original purchase against defects in manufacture.

More information

L-K INDUSTRIES BENCHMARK S MANUAL

L-K INDUSTRIES BENCHMARK S MANUAL L-K INDUSTRIES Demand a higher standard. BENCHMARK S MANUAL Heated Laboratory Centrifuge To set the standard for MANUFACTURING QUALITY and customer service in the PETROLEUM TESTING industry. Petroleum

More information

OPERATING INSTRUCTIONS FINISHER 4300

OPERATING INSTRUCTIONS FINISHER 4300 OPERATING INSTRUCTIONS FINISHER 4300 Model No. BA-FS43 Banner American Products, Inc. Temecula, CA Table of Contents I. For Your Safety... 2 II. Electrical Safeguards... 2-3 III. Specifications... 3 IV.

More information

Digital Body Weight Scale Model No.: EB4074C. Questions or Concerns? (855)

Digital Body Weight Scale Model No.: EB4074C. Questions or Concerns? (855) Digital Body Weight Scale Model No.: EB4074C Questions or Concerns? (855) 686-3835 support@etekcity.com 1 Thank You. Thank you for purchasing the EB4074C Digital Body Weight Scale by Etekcity. We are dedicated

More information

Instruction Manual. Backup Camera System With Replacement Mirror Display RVS N

Instruction Manual. Backup Camera System With Replacement Mirror Display RVS N Instruction Manual Backup Camera System With Replacement Mirror Display RVS-778718N Rear View Safety, Inc. 2016 1 NOTE! Please read all of the installation instructions carefully before installing the

More information

Owner s Guide. ca5354

Owner s Guide. ca5354 PROFESSIONAL SERIES Owner s Guide for models: ca5354 Deluxe Vehicle Remote Start System with 900Mhz 2 Way Confirming LED Remote Control IMPORTANT NOTE: The operation of the Security and Convenience System

More information

Microscope light manual

Microscope light manual Microscope light manual LS-12 and LS-14 LS-12 LS-14 1/9 Content Overview... 3 Mounting... 4 Light adjustment... 5 Mirror... 6 Filters... 6 Replacing microscope light... 7 Technical data... 8 Troubleshooting...

More information

Hydraulic Bead Breaker Kit

Hydraulic Bead Breaker Kit Hydraulic Bead Breaker Kit Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions

More information

CA 5054 Owner s Guide

CA 5054 Owner s Guide PROFESSIONAL SERIES CA 5054 Owner s Guide Remote Start and Keyless Entry System IMPORTANT NOTE: The operation of the Security and Convenience System as described in this manual is applicable to most vehicles.

More information

Model PKL Stereo Microscope Incident & Transmitted Light LED Pole Stand Instruction Manual

Model PKL Stereo Microscope Incident & Transmitted Light LED Pole Stand Instruction Manual Model PKL Stereo Microscope Incident & Transmitted Light LED Pole Stand Instruction Manual Table of Contents 1.0 Introduction 1.1 Product Features 1.2 General Safety Guidelines 1.3 Warning/Caution symbols

More information

Have a Bright Day! Nicholas Harmon President and CEO

Have a Bright Day! Nicholas Harmon President and CEO VD03 Dear Customer, Thank you for purchasing the Verilux Heritage Desk Lamp. You have received a quality product, backed by a three-year limited warranty. As a Verilux customer, your satisfaction means

More information

3000 SERIES DRY-BLOCK HEAT SOURCE

3000 SERIES DRY-BLOCK HEAT SOURCE 3000 SERIES DRY-BLOCK HEAT SOURCE USER MANUAL Please read this manual before switching the unit on IMPORTANT safety information inside TABLE OF CONTENTS 1 INTRODUCTION 1 2 SAFETY 2 3 OPERATION 3 3.1 Parts

More information

OPERATIONS MANUAL LEVER CHAIN HOIST

OPERATIONS MANUAL LEVER CHAIN HOIST OPERATIONS MANUAL LEVER CHAIN HOIST IMPORTANT SAFETY INFORMATION Please read, understand and follow all safety information contained in these instructions prior to the use of this hoist. Retain these instructions

More information

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument. ASTROAI USER MANUAL DIGITAL MULTIMETER NOTE: Fully read and understand this manual before using this instrument. WARNING: To avoid possible electric shock or personal injury, and to avoid possible damage

More information

Exterior Digital Load Scale 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation

Exterior Digital Load Scale 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation Exterior Digital Load Scale 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation 2 Exterior Digital Load Scale 201-EDG-01(B) Table of Contents Specifications & Overview

More information

Table of Contents. Safety Information Main Functions Set-Up Operation Maintenance Troubleshooting Specifications Customer Support Warranty Information

Table of Contents. Safety Information Main Functions Set-Up Operation Maintenance Troubleshooting Specifications Customer Support Warranty Information Model: LV-PUR131 True HEPA Air Purifier Questions or Concerns? Please contact us Mon-Fri 9:00AM-5:00PM PST at (888)726-8520 or email support@levoit.com Thank You. Thank you for purchasing the LV-PUR131

More information

TRACER. POCKETESTER ä ORP CODE 1742

TRACER. POCKETESTER ä ORP CODE 1742 TRACER POCKETESTER ä ORP CODE 1742 TRACER ORP POCKETESTER TM CODE 1742 Table of Contents Introduction... 4 Specifications... 4 Contents... 4 Parts & Accessories... 4 Meter Description Front Panel Description...

More information

Harvil 5 Foot Air Hockey Table

Harvil 5 Foot Air Hockey Table ASSEMBLY INSTRUCTIONS Harvil 5 Foot Air Hockey Table Thank you for your purchase of this Harvil product! We work around the clock and around the globe to ensure that Harvil products maintain the highest

More information

SAFETY PRECAUTIONS SAFETY FIRST!... 1 ABOUT THE CODE READER CONTROLS AND INDICATORS... 3 DISPLAY FUNCTIONS... 4

SAFETY PRECAUTIONS SAFETY FIRST!... 1 ABOUT THE CODE READER CONTROLS AND INDICATORS... 3 DISPLAY FUNCTIONS... 4 Table of Contents SAFETY PRECAUTIONS SAFETY FIRST!... 1 ABOUT THE CODE READER CONTROLS AND INDICATORS... 3 DISPLAY FUNCTIONS... 4 USING THE CODE READER CODE RETRIEVAL PROCEDURE... 7 VIEWING ABS DTCs...

More information

18VDC ESB6-X Series Cordless Screwdrivers Operation Manual

18VDC ESB6-X Series Cordless Screwdrivers Operation Manual 18VDC ESB6-X Series Cordless Screwdrivers Screwdriver Models : ESB6-X3.5, ESB6-X3.5F, ESB6-X5F ESB6-X6, ESB6-X9, ESB6-X12 CAUTION - Please read, understand, and follow all operating and safety instructions

More information

Bio Lion Table Top Centrifuge XC-L5

Bio Lion Table Top Centrifuge XC-L5 Bio Lion Table Top Centrifuge XC-L5 Operation Manual Table of contents Section Specification Page 1 Pictures Page 2-3 Starting Safety information Page 4 Set up Page 5-7 Operation Page 7-8 Troubleshooting

More information

OPERATION MANUAL PEN TYPE. Model: 8690 DESIGN PATENTED: US D S

OPERATION MANUAL PEN TYPE. Model: 8690 DESIGN PATENTED: US D S OPERATION MANUAL PEN TYPE PH METER DESIGN PATENTED: US D453.905S Model: 8690 INTRODUTION ongratulations on your purchase of the unique shape of ph pen model 8690, the meter features dual display ph with

More information

Have a Bright Day! Nicholas Harmon President, Verilux, Inc.

Have a Bright Day! Nicholas Harmon President, Verilux, Inc. VD03 Dear Customer, Thank you for purchasing the Verilux Heritage Deluxe Natural Spectrum Desk Lamp. You have received a quality product, backed by a one-year limited warranty. As a Verilux customer, your

More information

Digital Body Weight Scale Model No. EB4074C. Questions or Concerns? (855)

Digital Body Weight Scale Model No. EB4074C. Questions or Concerns? (855) Digital Body Weight Scale Model No. EB4074C Questions or Concerns? (855) 686-3835 support@etekcity.com Thank you for purchasing the Digital Body Weight Scale by Etekcity. This device can help you reach

More information

LIGHTNING PROTECTION UNIT (LPU)

LIGHTNING PROTECTION UNIT (LPU) LIGHTNING PROTECTION UNIT (LPU) Photovoltaic Lightning Protection Device Installation and Operation Manual SPECIALTY CONCEPTS, INC. 8954 Mason Ave. Chatsworth, CA 91311 USA MODELS COVERED: LPU-50, LPU-150,

More information

USER S GUIDE WARRANTY. This manual and all information contained herein is copyright HM Digital, Inc. ONE YEAR LIMITED WARRANTY

USER S GUIDE WARRANTY. This manual and all information contained herein is copyright HM Digital, Inc. ONE YEAR LIMITED WARRANTY WARRANTY USER S GUIDE ONE YEAR LIMITED WARRANTY The PH-200, manufactured by HM Digital, Inc. ("the Company") is warranted to the purchaser against defective materials and workmanship for one (1) year from

More information

Remove the 3-11mm nuts holding mirror on. Don t drop the nuts!

Remove the 3-11mm nuts holding mirror on. Don t drop the nuts! 2005-2012 Ford Mustang Puddle Lamp Kit Parts List: Quantity: Tool List: LED Lamps 2 Flat head screwdriver Seals 2 Ratchet & Socket set OR Nuts 2 Adjustable Wrench Wiring harness 1 Drill & 11/16 th bit

More information

Model 2053 Conductivity Meter Instruction Manual

Model 2053 Conductivity Meter Instruction Manual Model 2053 Conductivity Meter Instruction Manual Printed in U.S.A. 09/2006 Ship Date: Serial Number: Calibrated By: Table of Contents Page 1. Introduction.. 1 2. Shipping Checklist.. 1 3. Specifications...

More information

Digital Body Weight Scale

Digital Body Weight Scale Digital Body Weight Scale Model No.: EB4410B Questions or Concerns? Please contact us: (855) 686-3835 support@etekcity.com Thank You. Thank you for purchasing the Digital Body Weight Scale by Etekcity.

More information

Active Controlled Cooling System

Active Controlled Cooling System Active Controlled Cooling System April 2011 3267 Progress Dr Orlando, FL 32826 www.apecor.com Preliminary www.apecor.com Table of Contents General Information... 3 Safety... 3 Introduction... 3 What s

More information

MultiCal. Operation Manual for MultiCal mmhga/psia Pressure Module

MultiCal. Operation Manual for MultiCal mmhga/psia Pressure Module MultiCal Operation Manual for MultiCal mmhga/psia Pressure Module Contents Overview.... 1 Introduction... 1 Operation.... 2 Functions.... 2 Pressure Measurement... 2 Battery Replacement... 3 Calibration....

More information

CLEAN POWER TM CPS Series Operator s Manual

CLEAN POWER TM CPS Series Operator s Manual 12 Test Equipment CLEAN POWER TM CPS Series Operator s Manual Power Supply / Maintenance Charger for 12 Volt Systems The CPS series of power supplies / maintenance chargers are the ultimate in supplying

More information

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual Cardinal DETECTO PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual CARDINAL SCALE MFG. CO. PO BOX 151, WEBB CITY, MO 64870 0066-M176-O1 Rev H 10/06 417-673-4631 www.cardinalscale.com Printed

More information

series USER MANUAL

series USER MANUAL 888 534-5994 4000 series USER MANUAL Contents Here s all the information you need for setting and operating your new Lathem time recorder. Service information is also included in this manual, in case any

More information

Note: Please read through the entire guide before attempting any kind of installation.

Note: Please read through the entire guide before attempting any kind of installation. KIT-RSRTD Installation Guide Version 1.5 Auber Instruments, 730 Culworth Manor, Alpharetta, GA 30022 e-mail: info@auberins.com Tel: 770-569-8420 www.auberins.com This is a PID controller kit installation

More information

Owner s Guide CA 5055

Owner s Guide CA 5055 PROFESSIONAL SERIES Owner s Guide For Model: CA 5055 Vehicle Remote Start and Keyless Entry System IMPORTANT NOTE: The operation of the Security and Convenience System as described in this manual is applicable

More information

FUME HOOD. Installation and Operations Manual

FUME HOOD. Installation and Operations Manual FUME HOOD Installation and Operations Manual FUME HOOD Installation and Operations Manual Revision: June 2016 Page 2 of 7 FUME HOOD Installation and Operations Manual Revision: June 2016 Page 3 of 7 MODELS

More information

PHOENIX Amp Brushless Sensorless Speed Control. 1.0 Features of the Phoenix-25 : 2.3 Connecting the Motor. 2.4 Reversing Rotation

PHOENIX Amp Brushless Sensorless Speed Control. 1.0 Features of the Phoenix-25 : 2.3 Connecting the Motor. 2.4 Reversing Rotation 1.0 Features of the Phoenix-25 : Extremely Low Resistance (.013 ohms) High rate (7 KHz) switching (PWM) Up to 25 Amps continuous current with proper air flow, 35 amps surge Five to eight cells with four

More information

HVF110, 210, 310, 410HD

HVF110, 210, 310, 410HD 342 N. Co. Rd. 400 East Valparaiso, IN 46383 219-464-8818 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. HVF110, 210, 310, 410HD

More information

ROGOWSKI LEAK METER MODEL RLM-1

ROGOWSKI LEAK METER MODEL RLM-1 ROGOWSKI LEAK METER MODEL RLM-1 INSTRUCTION MANUAL Thank you very much for selecting our model RLM-1 Flexible Leakage Current Meter. This model is complex instrument and employ a very reliable mechanical/electronic

More information

MODEL 890 / 892 POWER POST 10 TON CAPACITY

MODEL 890 / 892 POWER POST 10 TON CAPACITY MODEL 890 / 892 POWER POST 10 TON CAPACITY Jackco Transnational Inc. LIMITED ONE YEAR WARRANTY Jackco Transnational Inc. warrants all Jackco equipment and tools to the original purchaser against any manufacturing

More information

Owner s Guide CA 4555

Owner s Guide CA 4555 PROFESSIONAL SERIES Owner s Guide For Model: CA 4555 Vehicle Remote Start System with 2 Way Confirming Remote Control IMPORTANT NOTE: The operation of the Security and Convenience System as described in

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Digital Clamp Meter DSA500A IMPORTANT: RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. If you find damage, notify the carrier at once. Shipping damage

More information

!"" #$% "!&' ( ( ) *

! #$% !&' ( ( ) * !"" #$% "!&' (( ) * FunPop Assembly Manual Model # 2649CR Part No. 59406CR Revised: October 2004 Cincinnati, OH 45241-4807 USA INSTALLATION INSTRUCTIONS Checking Shipment Unpack carton and check thoroughly

More information

AC POWER SOURCE PURE SINE WAVE DC-AC INVERTERS OWNER S MANUAL

AC POWER SOURCE PURE SINE WAVE DC-AC INVERTERS OWNER S MANUAL AC POWER SOURCE PURE SINE WAVE DC-AC INVERTERS MODEL: PST-15S-12A OWNER S MANUAL Please read this manual before operating your inverter. INDEX Contents General Safety & Installation... 3 Warning... 4 Description

More information

Owner s Guide. ca5154

Owner s Guide. ca5154 PROFESSIONAL SERIES Owner s Guide for models: ca5154 Automatic / Manual Transmission Remote Start and Keyless Entry System IMPORTANT NOTE: The operation of the Security and Convenience System as described

More information

(450 m-925 m) ET/MDPE Tape Water Level Meter (with optional electric rewind)

(450 m-925 m) ET/MDPE Tape Water Level Meter (with optional electric rewind) 1500-3000 (450 m-925 m) ET/MDPE Tape Water Level Meter (with optional electric rewind) Installation and Operation Manual Rev 08/30/12 Part # 12050339 Table of Contents Section 1: System Description.....

More information

6.0 SPECIFICATIONS CONTENTS. Calibration. According to factory procedureeeeeeeeeeeeeee Accuracy*

6.0 SPECIFICATIONS CONTENTS. Calibration. According to factory procedureeeeeeeeeeeeeee Accuracy* 6.0 SPECIFICATIONS Calibration According to factory procedureeeeeeeeeeeeeee Accuracy* ± 1% full scale (FS) or ± 1 graduation on scale Scale diameter 41 mm Temperature range 45 to 115 F (10-45 C) Air humidity

More information

Troubleshooting Guide for Limoss Systems

Troubleshooting Guide for Limoss Systems Troubleshooting Guide for Limoss Systems NOTE: Limoss is a manufacturer and importer of linear actuators (motors) hand controls, power supplies, and cables for motion furniture. They are quickly becoming

More information

Thermistor Thermometer MODEL NO

Thermistor Thermometer MODEL NO Digi -Sense Thermistor Thermometer MODEL NO. 60010-70 Digi -Sense CERTIFICATE OF CONFORMANCE This thermometer was calibrated using equipment traceable to the National Institute of Standards and Technology

More information

TABLE OF CONTENTS NOTES. 1.0 Operating principle... 02

TABLE OF CONTENTS NOTES. 1.0 Operating principle... 02 OI-001 NOTES TABLE OF CONTENTS 1.0 Operating principle.............................................. 02 2.0 Overview....................................................... 03 2.1 Operating elements 2.2

More information

5.2 PRE-OPERATION PROCEDURE WARRANTY

5.2 PRE-OPERATION PROCEDURE WARRANTY 4/02 Form #314 OPERATING INSTRUCTIONS MODELS DM-210A, 220A, 230A DIGITAL MULTIMETER PLEASE READ THESE OPERATING INSTRUCTIONS CAREFULLY Misuse and or abuse of these instruments cannot be prevented by any

More information

Drip-n-Gro Dual Top Feed Drip System Instruction Manual

Drip-n-Gro Dual Top Feed Drip System Instruction Manual Notes: Hydrogardening Bucket Systems Drip-n-Gro Dual Top Feed Drip System Instruction Manual 1 Square = 1 Foot Exclusively distributed by: Exclusively distributed by: www.sunlightsupply.com www.flo-n-gro.net

More information

Lumitester PD-30. Instruction Manual. Table of Contents

Lumitester PD-30. Instruction Manual. Table of Contents Table of Contents Lumitester PD-30 Instruction Manual Thank you very much for purchasing the Lumitester PD-30. All of this Instruction Manual must be read before operation of this product for safe and

More information

Uplift Premium Power Lifting Seat

Uplift Premium Power Lifting Seat Uplift Premium Power Lifting Seat User Guide Read all instructions before using the Uplift Power Seat DANGER - To reduce the risk of electric shock: IMPORTANT SAFETY INSTRUCTIONS Always unplug the Uplift

More information

IMPORTANT SAFETY INFORMATION

IMPORTANT SAFETY INFORMATION Specifications Overall Dimensions Batteries 9" L x 6-3/4" W x 6-3/4" H 4 - AA (sold separately) IMPORTANT SAFETY INFORMATION Installation Precautions 1. Verify that installation surface has no hidden utility

More information