1 LPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions ADCP Issue 1 6/2010 Content Page INTRODUCTION DESCRIPTION RACK INSTALLATION Mounting Bracket Options Installing the Enclosure in the Equipment Rack CABLE INSTALLATION Securing Cables to the Enclosure Routing Cable Fibers to Splice Trays SPLICING PATCH CORD ROUTING AND INSTALLATION CUSTOMER INFORMATION AND ASSISTANCE INTRODUCTION This manual provides a description of the Low Profile Cabinet (LPC) 12/24 Fiber Rack-Mount Enclosure plus the installation and cable routing procedures. The LPC 12/24 enclosure is a rackmount terminal that is designed for customer premise applications and other remote fiber locations that require a low-profile cabinet. The LPC 12/24 enclosure terminates either 12 or 24 fibers (depending on the option ordered) and supports both ribbon mass fusion splicing and single fiber splicing Rev A Page 1

2 Revision History ISSUE DATE REASON FOR CHANGE 1 6/2010 Original List of Changes PAGE IDENTIFIER DESCRIPTION OF CHANGE All New Trademark Information ADC is a registered trademark of ADC Telecommunications, Inc. Admonishments Important safety admonishments are used throughout this manual to warn of possible hazards to persons or equipment. An admonishment identifies a possible hazard and then explains what may happen if the hazard is not avoided. The admonishments in the form of Dangers, Warnings, and Cautions must be followed at all times. These warnings are flagged by use of the triangular alert icon (seen below), and are listed in descending order of severity of injury or damage and likelihood of occurrence. Danger: Danger is used to indicate the presence of a hazard that will cause severe personal injury, death, or substantial property damage if the hazard is not avoided. Warning: Warning is used to indicate the presence of a hazard that can cause severe personal injury, death, or substantial property damage if the hazard is not avoided. Caution: Caution is used to indicate the presence of a hazard that will or can cause minor personal injury or property damage if the hazard is not avoided. General Safety Precautions Caution: Fiber optic cables may be damaged if bent or curved to a radius that is less than the recommended minimum bend radius. Always observe the recommended bend radius limit when installing fiber optic cables and patch cords. Danger: Exposure to laser radiation can seriously damage the retina of the eye. Do not look into the ends of any optical fiber. Do not assume the laser power is turned-off or that the fiber is disconnected at the other end. Caution: Improper handling can damage fiber optic cables. Do not bend fiber optic cable more sharply than the minimum recommended bend radius specified by the cable manufacturer. Do not apply more pulling force to the cable than specified. Do not compress the fiber or allow it to kink. Page 2

3 1 DESCRIPTION The LPC 12/24 enclosure (hereafter referred to as the LPC enclosure) is a rack-mount terminal designed for customer premise applications and other remote fiber locations that require a lowprofile cabinet. The LPC enclosure, shown in Figure 1, is available in a 12 or 24 fiber version. Both versions are pre-loaded with SC adapters, SC ultra PC ribbon pigtail assemblies, and splice trays that support mass fusion or single fiber splicing. Universal mounting brackets allow the LPC enclosure to be mounted in either a 19- or 23-inch EIA equipment rack. The mounting brackets can be installed for flush mounting, recessed 2.58 inches (6.6 cm), or recessed 4.78 inches (12.1 cm) IN (27.9 CM) 2.58 IN (6.6 CM) 3.5 IN (8.9 CM) 17.0 IN (43.2 CM) A Figure 1. Typical LPC Enclosure The front side of the LPC enclosure is equipped with a hinged front cover made of tinted plastic and a sliding top cover also made of tinted plastic. A round hole is provided in the front cover for mounting an optional lock set. Opening the front cover and removing the top cover provides access to the front side of the bulkhead adapters. Openings are provided on the right and left sides of the LPC enclosure to allow patch cords to be routed into the front of the enclosure for connection to the bulkhead adapters. All adapters face toward the front of the enclosure. The rear side of the LPC enclosure is equipped with a sheet metal cover. Removing the rear cover provides access to rear side of the bulkhead adapters, the SC ultra PC ribbon pigtail assembly, and the splice tray(s). Mounting points are provided for clamping fiber optic cables to the rear side of the enclosure. Fiber optic cables may also be secured directly to the slotted rail provided at the back of the enclosure using a stainless steel hose clamp. The basic components of the LPC enclosure are shown in Figure 2. One splice tray is provided with the 12 fiber LPC enclosure (LPC-12) and two splice trays are provided with the 24 fiber LPC enclosure (LPC-24). An accessory package is included with each enclosure that contains caution/warning labels, patching scheme grid label, cable ties, cable tie anchors, cable clips, and mounting screws. Page 3

4 REAR COVER UNIVERSAL MOUNTING BRACKET (LEFT SIDE) SPLICE TRAY BULKHEAD ADAPTER ASSEMBLY UNIVERSAL MOUNTING BRACKET (RIGHT SIDE) D TOP COVER HINGED FRONT COVER Figure 2. LPC Enclosure Components 2 RACK INSTALLATION The following sections provide instructions for mounting the LPC enclosure in an equipment rack. The tools required for completing these sections include the following Phillips screwdrivers (#1 and #2) 2.1 Mounting Bracket Options The LPC enclosure can be mounted in either a 19- or 23-inch equipment rack. One set of universal mounting brackets is provided with the enclosure. The enclosure can be flush mounted, recessed 2.58 inches (6.6 cm), or recessed 4.78 inches (12.1 cm). The mounting brackets are slotted to allow the enclosure to be mounted in racks with EIA 1.25-inch (3.18 cm) hole spacing. The LPC enclosure is shipped with mounting brackets configured for mounting in a 19-inch EIA rack with a 2.58 inch recess. The brackets must be removed and reinstalled as shown in Figure 3 if another mounting option is required. Warning: Never install equipment in a wet location or during a lightning storm. When installing or modifying communication lines, disconnect lines at the network interface before working with uninsulated lines or terminals. Page 4

5 FLUSH MOUNT HOLES 2.58 INCH (6.6 CM) RECESS HOLES 4.78 INCH (12.1 CM) RECESS HOLES BRACKET INSTALLATION FOR 19-INCH RACK BRACKET INSTALLATION FOR 23-INCH RACK A 2.2 Installing the Enclosure in the Equipment Rack Figure 3. Mounting Bracket Installation Options Secure the LPC enclosure to the equipment rack using the four pan-head screws provided in the accessory package. Align the holes in the mounting brackets with the holes in the rack as shown in Figure 4. Place a #12 flat washer or star washer under each screw head if required by local practice. Note: Figure 4 shows how to install the LPC enclosure in a typical 19-inch EIA rack. The mounting brackets in the example have been installed to provide a 2.58-inch recess SCREWS (4) A Figure 4. Install LPC Enclosure into Rack Page 5

6 3 CABLE INSTALLATION The following sections provide instructions for securing a ribbon-type fiber optic cable to the rear of the LPC enclosure and for routing the cable fiber ribbon to a splice tray. The LPC-12 enclosure is pre-loaded with one 12-fiber ribbon pigtail assembly and the LPC-24 is pre-loaded with two 12-fiber ribbon pigtail assemblies. The pigtail assemblies are routed to the splice tray(s) and are ready for splicing to the fiber optic cable. The tools and materials required for completing these sections include the following: Phillips screwdriver (#2) Tools to strip off the cable sheath to expose the fiber ribbons Tape measure Pen or marker Wire cutter Breakout kit for fiber ribbon (recommended) 3.1 Securing Cables to the Enclosure The fiber optic cable may be routed to the LPC enclosure from either the left or right side. Before starting, remove the enclosure rear cover to provide full access to the splice trays and the cable attachment points at the rear side of the enclosure. Two methods may be used to attach the cable to the enclosure. Use the method that is appropriate for the installation and that complies with local practice. 1. Route the fiber optic cable to the rear of the LPC enclosure and remove approximately 64 inches of cable sheathing to expose the fiber ribbon(s). Note: Removing 64 inches of sheath will provide sufficient length for coiling the fiber ribbon(s) at least once around the splice tray(s). This will also provide sufficient ribbon length for a slack loop within the splice tray. 2. If required by local practice, install a breakout kit to protect the fiber ribbon(s). Follow the installation instructions provided with the kit. Note: A breakout kit is recommended when installing ribbon cable. The breakout kit includes a plastic tube that protects the fiber ribbon and prevents damage. 3. Secure the cable to the enclosure using either a cable clamp kit (must be ordered separately) or a stainless steel clamp as shown in Figure 5. Note: If possible, the cable should be attached to the side of the enclosure that will allow the cable fibers to be coiled around the splice tray in the same direction as the pigtail assembly is coiled. This will greatly simply removal of the splice tray for splicing. Page 6

7 GROMMET (SIZE DETERMINED BY DIAMETER OF CABLE) RIBBON PIGTAIL ASSEMBLY ROUTED TO SPLICE TRAY PLATE 1/4-20 SCREW (2) YOKE (2) SECURING CABLE WITH CLAMP KIT (TYPICAL) SPLICE TRAY STAINLESS STEEL BAND CLAMP C SECURING CABLE WITH BAND (TYPICAL) 3.2 Routing Cable Fibers to Splice Trays Figure 5. Attach Fiber Optic Cable to LPC Enclosure (LPC-12 Enclosure Shown) From the clamping point, the cable fibers must be routed to the splice tray. The cable fibers should be coiled as least once around the splice tray to provide a slack loop for removing the splice tray. Use the following procedure to route cable fibers to the splice trays: 1. From the point at which the cable is clamped or secured to the enclosure, route the cable fibers into the LPC enclosure and around the splice tray as shown in Figure 6. Note: If possible, coil the cable fibers in the same direction around the splice tray as the pigtail assembly. FIBER ATTACHMENT POINT ON SPLICE TRAY CABLE FIBERS (RIBBON) SPLICE TRAY PIGTAIL ASSEMBLY A Figure 6. Routing Cable Fibers for Splicing Page 7

8 2. Locate the point on the splice tray where the pigtail assembly is attached and route the cable fibers to the same point. 3. Provide a sufficient slack loop to allow the splice tray to be removed from the enclosure for splicing. 4 SPLICING The LPC-12 enclosure is equipped with one splice tray and the LPC-24 enclosure is equipped with two splice trays. Each splice tray is loaded with foam splice holders for ribbon fusion splicing. The ribbon pigtail assembly is pre-attached to each splice tray. The tools and materials required for completing these sections include the following: Splicing equipment Wire cutter Pen or marker Use the following procedure to secure the cable fibers to the splice tray and to reinstall the splice tray in the enclosure when splicing is completed: 1. Mark the protective tube that covers the cable fiber ribbon at the point where the tube will be attached to the splice tray as shown in Figure 7. ATTACHMENT POINT FOR CABLE FIBER A ATTACHMENT POINT FOR PIGTAIL FIBER Figure 7. Splice Tray Fiber Attachment Points and Routing 2. Cut the protective tube (don t cut the cable fiber ribbon) at the point marked in step 1 and remove the protective tube to expose the ribbon. 3. Remove the splice tray from the enclosure and carefully uncoil both the cable fibers and the pigtail assembly fibers from the enclosure. 4. Remove both the external splice tray cover and the internal splice tray cover as shown in Figure Use a cable tie and rubber sleeve to secure the end of the protective tube to the splice tray. Page 8

9 EXTERNAL COVER CABLE TIE FIBER RIBBON INTERNAL COVER RUBBER SLEEVE A Figure 8. Splice Tray Assembly 6. Splice the cable ribbon fibers to the pigtail assembly fibers as specified by local policies and procedures. Adjust and route the fibers within the splice tray (see Figure 7) as needed. 7. When splicing is completed, re-install the internal and external covers on the splice tray. 8. Attach appropriate warning and designation labels as specified by local policies and procedures. 9. Carefully re-install the splice tray and attached optical fibers in the LPC enclosure. 10. The cable management components shown in Figure 9 are provided in the accessory package. Use these components as needed to secure the cable fibers and pigtail assembly fibers within the enclosure and to provide bend radius protection as shown in Figure Re-install the LPC enclosure rear cover when splicing is completed. CABLE TIE TWIST CLIP CABLE TIE ANCHOR A Figure 9. Cable Management Components Page 9

10 SUPER LABEL CABLE TIES TWIST CLIP ANCHOR A Figure 10. Secure Cable Fibers and Pigtail Assembly Fibers Within Enclosure 5 PATCH CORD ROUTING AND INSTALLATION Patch cords may be routed into the LPC enclosure through openings on the left and right sides of the chassis. The bulkhead adapters are numbered for identification. When making a connection, use patch cords that are terminated with SC ultra PC connectors. Use the following procedure to connect a patch cord to an optical port: 1. Open the LPC enclosure front cover and remove the plastic top cover as shown in Figure Locate the optical port to which the patch cord will be connected and remove the dust cap from the optical port. 3. Remove the ferrule dust cap from the patch cord connector and clean the connector as specified in the Optical Fiber Connector Wet and Dry Cleaning Instructions (ADCP ) or by locally approved procedures. 4. Insert the patch cord connector into the bulkhead adapter. 5. Attach patching grid label (provided in accessory package) to an appropriate location and record the patch cord connection. 6. When all patch cord connections are completed, re-install the plastic top cover and close the front cover. Page 10

11 3. CLEAN AND INSERT CONNECTOR 2. REMOVE FERRULE DUST CAP 1. REMOVE ADAPTER DUST CAP A Figure 11. Patch Cord Routing and Installation Page 11

12 6 CUSTOMER INFORMATION AND ASSISTANCE PHONE: U.S.A. or CANADA Sales: Extension Technical Assistance: Connectivity Extension: Wireless Extension: EUROPE Sales Administration: Technical Assistance: EUROPEAN TOLL FREE NUMBERS Germany: UK: Spain: France: Italy: ASIA/PACIFIC Sales Administration: Technical Assistance: ELSEWHERE Sales Administration: Technical Assistance: WRITE: Q ADC Telecommunications (S PORE) PTE, LTD; 100 Beach Road, #18-01, Shaw Towers. Singapore ADC Telecommunications, INC PO Box 1101, Minneapolis, MN , USA ADC European Customer Service, INC Belgicastraat 2, 1930 Zaventem, Belguim PRODUCT INFORMATION AND TECHNICAL ASSISTANCE: REPRINTS: PDF copies of manuals are available for downloading at the following link: ADCP Number: Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period. Page 12

12-Inch Hybrid Fiber Access Terminal Installation Instructions

12-Inch Hybrid Fiber Access Terminal Installation Instructions 12-Inch Hybrid Fiber Access Terminal Installation Instructions 19683-A Content Page 1 PRODUCT DESCRIPTION.................................................................. 2 2 PRODUCT FUNCTION.....................................................................

More information

American Standard ProAx Triaxial Camera Connectors Installation Instructions

American Standard ProAx Triaxial Camera Connectors Installation Instructions American Standard ProAx Triaxial Camera Connectors Installation Instructions Content Page INTRODUCTION............................................................................. 1 Revision History........................................................................

More information

FL2000 Termination/Splice Panels User Manual

FL2000 Termination/Splice Panels User Manual FL2000 Termination/Splice Panels User Manual Content Page INTRODUCTION... 1 Revision History... 1 List of Changes... 1 Trademark Information... 2 Related Publications... 2 Admonishments... 2 General Safety

More information

Fiber Splice Panel Rack Mount User Manual

Fiber Splice Panel Rack Mount User Manual Fiber Splice Panel Rack Mount User Manual Content Page INTRODUCTION... 1 Revision History... 1 List of Changes... 1 Trademark Information... 2 Admonishments... 2 1. DESCRIPTION... 2 A. Product Definition

More information

PowerWorx DSX Series GMT Fuse Panel User Manual

PowerWorx DSX Series GMT Fuse Panel User Manual PowerWorx DSX Series GMT Fuse Panel User Manual ADCP-80-538 Issue 4 2/2012 1206873 Rev E Preface COPYRIGHT 2011, Tyco Electronics Corporation All Rights Reserved REVISION HISTORY ISSUE DATE REASON FOR

More information

1 GENERAL INFORMATION

1 GENERAL INFORMATION Broadcast and Entertainment Products ProAx Triaxial Camera Connectors Installation Instructions Content Page 1 GENERAL INFORMATION... 2 1.1 Standard Tools... 3 1.2 ADC ProAx Triaxial Cable Strip Gauge...

More information

DS1 Plug-In Digital Signal Cross-Connect (PIX-DSX-1) 19-Inch Shelf Kit Installation Instructions

DS1 Plug-In Digital Signal Cross-Connect (PIX-DSX-1) 19-Inch Shelf Kit Installation Instructions DS Plug-In Digital Signal Cross-Connect (PIX-DSX-) 9-Inch Shelf Kit Installation Instructions Contents Page INTRODUCTION... Revision History... List of Changes... Trademark Information... Related Publications...2

More information

LSW Connector Module User Manual

LSW Connector Module User Manual LSW Connector Module User Manual Content Page INTRODUCTION............................................................................. 2 Revision History........................................................................

More information

DSXi Product Family Digital Signal Cross-Connect Panels User Manual

DSXi Product Family Digital Signal Cross-Connect Panels User Manual DSXi Product Family Digital Signal Cross-Connect Panels User Manual ADCP-80-535 Issue 2 08/2009 REAR CROSS-CONNECT PANEL FRONT-BELOW CROSS-CONNECT PANEL TOTAL FRONT-ACCESS CROSS-CONNECT PANEL FRONT-SPLIT

More information

Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide)

Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide) Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide) 13536-A Figure 1. ACE-200DS Enclosure With OCM-HD Panels Content Page INTRODUCTION... 2 1 PRODUCT DESCRIPTION...

More information

PowerWorx Power Distribution Products Select Series Circuit Breaker for ±24 or ±48 Vdc User Manual

PowerWorx Power Distribution Products Select Series Circuit Breaker for ±24 or ±48 Vdc User Manual PowerWorx Power Distribution Products Select Series Circuit Breaker for ±24 or ±48 Vdc User Manual ADCP-80-580 Issue 3 11/2010 17943-A Circuit Breaker for ±24 or ±48 Vdc 1474485 Rev C Preface COPYRIGHT

More information

Fiber Connector Shelf (CCS)

Fiber Connector Shelf (CCS) Corning Cable Systems Standard Recommended Procedure (SRP) 003-595 Issue 3, May 2007 Page 1 of 6 Fiber Connector Shelf (CCS) Table of Contents 1. General... 1 2. Precautions... 1 3. Components... 2 4.

More information

8400 Series Fiber Distribution System

8400 Series Fiber Distribution System 8400 Series Fiber Distribution System Instructions January 1997 34-7041-4699-1-A 1 Contents: 1.0 General... 3 2.0 System Components... 4 3.0 System Engineering... 5 4.0 Hardware Installation... 7 5.0 Cable

More information

PowerWorx GMT Series Power Distribution Panel Uninterrupted (C-Source) Power User Manual

PowerWorx GMT Series Power Distribution Panel Uninterrupted (C-Source) Power User Manual Content PowerWorx GMT Series Power Distribution Panel Uninterrupted (C-Source) Power User Manual Page INTRODUCTION...2 Revision History...5 Trademark Information...5 Admonishments...5 General Safety Precautions...6

More information

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB) 1. Precautions 2. Carton Contents Pretium Wall-Mountable Housing OR Fiber Zone Box (FZB-02P-JB) PWH-02P and FZB-02B-JP have: (15 inches) edge grommet (1) Laser warning label (2) Fiber identification labels

More information

FIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

FIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails FIST-GSS2 FIST-GSS3 I N S T A L L A T I O N I N S T R U C T I O N Fist Generic Splicing Shelf Contents 1 Introduction 2 General 2.1 Kit content 2.2 Tools 3 Installation of the shelf 3.1 Mounting the shelf

More information

Environmental Distribution Center (EDC-06P-NH)

Environmental Distribution Center (EDC-06P-NH) Corning Cable Systems Standard Recommended Procedure (SRP) 003-545 Issue 4, July 2004 Page 1 of 13 Environmental Distribution Center (EDC-06P-NH) 1.2 To purchase any accessories that are sold separately,

More information

FIST-GMS2. FIST Generic Mixed Shelf MK2. Contents. 1 Introduction. 5 Termination of the pigtails. 2 General. 6 Splicing + fiber storage

FIST-GMS2. FIST Generic Mixed Shelf MK2. Contents. 1 Introduction. 5 Termination of the pigtails. 2 General. 6 Splicing + fiber storage FIST-GMS2 I N S T A L L A T I O N I N S T R U C T I O N FIST Generic Mixed Shelf MK2 Contents 1 Introduction 2 General 2.1 Kit content 2.2 Tools 2.3 Optional extra s 3 Installation of the shelf 3.1 Mounting

More information

Universal Splice Tray Installation Instructions

Universal Splice Tray Installation Instructions Universal Splice Tray Installation Instructions Table of Contents General Product Information... 1.0 Safety Precautions... 2.0 Package Contents... 3.0 Installing the Product... 4.0 Tower Mounting... 5.0

More information

FIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

FIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails FIST-GSS2 I N S T A L L A T I O N I N S T R U C T I O N Fist Generic Splicing Shelf MK2 Contents 1 Introduction 2 General 2.1 Kit content 2.2 Tools 2.3 Optional extra s 3 Installation of the shelf 3.1

More information

FIBER CONNECTOR SAFETY WARNINGS

FIBER CONNECTOR SAFETY WARNINGS FIBER CONNECTOR SAFETY WARNINGS SAFETY INFORMATION 1. Always wear safety glasses. 2. Isopropyl alcohol is flammable and may cause eye irritation. In case of contact with eyes, flush with water for at least

More information

PanView iq (PViQ) Fiber Tray

PanView iq (PViQ) Fiber Tray PVQ-FMT PanView iq (PViQ) Fiber Tray Part Number: PVQ-FMT Contents: 1 - FIBER TRAY (HOUSING & DRAWER) 6 - #12-24 x 1/2" SCREWS 6 - M6 x 1.0 x 16 SCREWS 2 - STRAIN RELIEF BRACKETS 2 - #10-32 BLACK HEX NUTS

More information

Instructions for Use - Opt-X 1000i Enclosure

Instructions for Use - Opt-X 1000i Enclosure 5R1UM-F03, 5R1UM-S03, 5R2UM-F06, 5R2UM-S06, 5R3UM-F09, 5R3UM-F12, 5R4UM-F12, 5R4UM-F15 Instructions for Use - Opt-X 1000i Enclosure 5R1UM-*03 5R2UM-*06 5R3UM-F** 5R4UM-F** Page 1 of 8 Leviton Network Solutions,

More information

FIST-FPS. Front Patching Shelf. Contents. 1 Introduction. 3 Installation of the shelf. 2 General. 1 Introduction

FIST-FPS. Front Patching Shelf. Contents. 1 Introduction. 3 Installation of the shelf. 2 General. 1 Introduction FIST-FPS I N S T A L L A T I O N I N S T R U C T I O N Front Patching Shelf Contents 1 Introduction 2 General 2.1 Kit content 2.2 Tools 3 Installation of the shelf 3.1 Side cable termination directly on

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 144F TABLE OF CONTENTS GENERAL... 2 SPECIFICATIONS... 2 PACKAGE CONTENTS... 2 PACKAGE CONTENTS: ACCESSORIES... 3 REQUIRED TOOLS... 3 ADD-ON COMPONENTS... 3 CABINET MOUNTING WALL MOUNT BRACKET ATTACHMENT...

More information

19 1HU Splicing and Front Patching Shelf

19 1HU Splicing and Front Patching Shelf FOMS-FPS-O-XXXX-XX I N S T A L L A T I O N I N S T R U C T I O N 19 1HU Splicing and Front Patching Shelf Contents 1 Introduction 2 General 2.1 Characteristics 2.2 Kit contents 2.3 Tools 3 Installation

More information

FIST-GPS2-J. 19 2HU Splicing, Patching and Storage shelf. 5 Fiber routing. 1 Introduction. Contents. 2 General. 6 Storage. 3 Installation of the shelf

FIST-GPS2-J. 19 2HU Splicing, Patching and Storage shelf. 5 Fiber routing. 1 Introduction. Contents. 2 General. 6 Storage. 3 Installation of the shelf FIST-GPS2-J I N S T A L L A T I O N I N S T R U C T I O N 19 2HU Splicing, Patching and Storage shelf Contents 1 Introduction 2 General 2.1 Kit contents 2.2 Tools 2.3 Optional extras 3 Installation of

More information

Patching & Splicing Shelf. 4.2 Side cable termination directly on the shelf using cable termination plate. IFC cable/break-out cable

Patching & Splicing Shelf. 4.2 Side cable termination directly on the shelf using cable termination plate. IFC cable/break-out cable FIST-GPS2/GPST-12 I N S T A L L A T I O N I N S T R U C T I O N Patching & Splicing Shelf Contents 1 Introduction 2 General 2.1 Kit contents 2.2 Tools 2.3 Optional accessories 3 Installation of the shelf

More information

Opticom Rack Mount Fiber Enclosures

Opticom Rack Mount Fiber Enclosures Opticom Rack Mount Fiber Enclosures Part Numbers: FRME1U, FRME2U Panduit Corp. 2011 INSTALLATION INSTRUCTIONS FRME1U FRME2U Contents - (#) indicates FRME2U quantity 1 - ENCLOSURE 2 - MOUNTING BRACKETS

More information

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions Issue 6, June 2014 SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions General The SYSTIMAX 360 ipatch InstaPATCH fiber shelf is a SYSTIMAX approved product and is available in a sliding configuration

More information

SPEC SHEET. OmniReach FTTX Solutions. NEMA Fiber Demarcation Box (FDB) Features

SPEC SHEET. OmniReach FTTX Solutions. NEMA Fiber Demarcation Box (FDB) Features ADC s OmniReach FTTX Solutions are the industry s first infrastructure solutions designed from the ground up to meet the unique requirements of FTTX networks. Designed for operational efficiency and scalability,

More information

FOSC-400D5 INSTALLATION INSTRUCTION. Fibre Optic Splice Closure with integrated organiser system

FOSC-400D5 INSTALLATION INSTRUCTION. Fibre Optic Splice Closure with integrated organiser system FOSC-400D5 INSTALLATION INSTRUCTION Fibre Optic Splice Closure with integrated organiser system 1 General 1.1 The installation instruction describes the necessary steps to install the FOSC-400D5. The

More information

Mini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide.

Mini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide. Mini-OTE 400 INSTALLATION INSTRUCTION TC-1335-IP Rev C, March 2017 www.commscope.com Mini-OTE 400 Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide 2 Tools Required

More information

Instructions for Use - Opt-X Ultra Enclosure Directives Enceintes Opt-X Ultra MC Instrucciones de Uso Caja Opt-X Ultra MR

Instructions for Use - Opt-X Ultra Enclosure Directives Enceintes Opt-X Ultra MC Instrucciones de Uso Caja Opt-X Ultra MR 5R1UH-S03 5R2UH-S06 5R4UH-S12 Instructions for Use - Opt-X Ultra Enclosure Directives Enceintes Opt-X Ultra MC Instrucciones de Uso Caja Opt-X Ultra MR 5R1UH-S03 5R2UH-S06 5R4UH-S12 Page 1 of 26 Leviton

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS GENERAL...2 SPECIFICATIONS...2 PACKAGE CONTENTS...2 PACKAGE CONTENTS: ACCESSORIES...3 REQUIRED TOOLS...3 ADD-ON COMPONENTS...3 CABINET MOUNTING HAND-HOLE OR VAULT...3 CABINET MOUNTING

More information

C Power Connection Kit

C Power Connection Kit 1548-4000C Power Connection Kit For use with Dekoron 2700 Family of Heating Cables Installation Instructions Kit Description The Dekoron 1548-4000C electrical connection kit distirbuted by Heat-Line is

More information

SYSTIMAX 360 ipatch G2 High Density Sliding Fiber Shelf Instructions

SYSTIMAX 360 ipatch G2 High Density Sliding Fiber Shelf Instructions Instruction Sheet 860445121 Issue 2, December 2012 SYSTIMAX Solutions SYSTIMAX 360 ipatch G2 High Density Sliding Fiber Shelf Instructions General The SYSTIMAX 360 ipatch G2 High Density Sliding Fiber

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS GENERAL...2 SPECIFICATIONS...2 PACKAGE CONTENTS...2 PACKAGE CONTENTS: ACCESSORIES...3 REQUIRED TOOLS...3 ADD-ON COMPONENTS...3 CABINET MOUNTING HAND-HOLE OR VAULT...3 CABINET MOUNTING

More information

ipatch Ready Upgrade Kit for SYSTIMAX 360 Fiber Shelves Instructions

ipatch Ready Upgrade Kit for SYSTIMAX 360 Fiber Shelves Instructions Instruction Sheet 860463090 Issue 3, December 2012 SYSTIMAX Solutions ipatch Ready Upgrade Kit for SYSTIMAX 360 Fiber Shelves Instructions General These instructions describe how to install ipatch Ready

More information

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, MPO Distribution Panel Instructions

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, MPO Distribution Panel Instructions Instruction Sheet 860564699 Issue 2, January 2014 SYSTIMAX Solutions SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, MPO Distribution Panel Instructions General The SYSTIMAX 360 fiber optic

More information

3M Fiber Dome Closure FDC 10

3M Fiber Dome Closure FDC 10 3M Fiber ome losure F 10 With 3M Fiber Optic Splice Tray 2541 Instructions 1.0 General 2.0 Kit ontents The 3M Fiber ome losure F 10 can accommodate two 1.06" (27 mm) main cables, five 0.71" (18 mm) branch

More information

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits 3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits With High-K Stress Relief For 3-Conductor Type G (Ground Wire), Copper Tape Shield, Armored Cables 7600-S-3G Series Instructions IEEE Std.

More information

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

COYOTE 28 GLC (Ground Level Closure) Complete Assembly Installation NOVEMBER 2016 COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED

More information

FOSC-400A4 INSTALLATION INSTRUCTION

FOSC-400A4 INSTALLATION INSTRUCTION FOSC-400A4 INSTALLATION INSTRUCTION TC-441-IP Rev A, Mar 2017 www.commscope.com Fibre Optic Splice Closure with integrated organiser system 1 General 1.1 The installation instruction describes the necessary

More information

IBER DISTRIBUTION FRAME (FDF) FOR EXCHANGE SIZE 900MM x 2200MM x 300 MM

IBER DISTRIBUTION FRAME (FDF) FOR EXCHANGE SIZE 900MM x 2200MM x 300 MM F 19 Rack Exchange & Shelf Unit IBER DISTRIBUTION FRAME (FDF) FOR EXCHANGE SIZE 900MM x 2200MM x 300 MM 1. General : 1.1 This specification covers the requirements of the fiber distribution frame (FDF)

More information

Fiber optic splice closure

Fiber optic splice closure FOSC-450A I N S T A L L A T I O N I N S T R U C T I O N TC-772-IP Rev A, Mar 2017 www.commscope.com Fiber optic splice closure Content 1 Introduction 2 General 2.1 Kit content 2.2 Tools 2.3 Accessories

More information

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, LC InstaPATCH Distribution Panel Instructions

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, LC InstaPATCH Distribution Panel Instructions Instruction Sheet 860564707 Issue 2, January 2014 SYSTIMAX Solutions SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, LC InstaPATCH Distribution Panel Instructions General The SYSTIMAX 360

More information

Alcatel-Lucent 7310 DC Metro Cell AWS (B4) Kit MC-DBR1, MC-DBR2, MC-DBR3, MC-DBR4, MC-DBR5. Installation Manual

Alcatel-Lucent 7310 DC Metro Cell AWS (B4) Kit MC-DBR1, MC-DBR2, MC-DBR3, MC-DBR4, MC-DBR5. Installation Manual Alcatel-Lucent 7310 DC Metro Cell AWS (B4) Kit MC-DBR1, MC-DBR2, MC-DBR3, MC-DBR4, MC-DBR5 Installation Manual ALCATEL-LUCENT DC METRO CELL AWS (B4) KIT INSTALLATION INSTRUCTIONS Document Information Identification

More information

OFS 400A FIBER OPTIC INTERCONNECT Instruction Sheet UNIT (FOIU) Comcode INSTALLATION

OFS 400A FIBER OPTIC INTERCONNECT Instruction Sheet UNIT (FOIU) Comcode INSTALLATION OFS 400A FIBER OPTIC INTERCONNECT 636-299-109-01 Instruction Sheet UNIT (FOIU) Comcode 846 586 212 INSTALLATION This instruction sheet covers the 400A1 (106266901) and 400A2 (106414170) Fiber Optic Interconnect

More information

SYSTIMAX G2 4U Fixed Rear Access Combination Shelf Instructions

SYSTIMAX G2 4U Fixed Rear Access Combination Shelf Instructions Instruction Sheet 860452176 SYSTIMAX Solutions SYSTIMAX 360 360G2 4U Fixed Rear Access Combination Shelf Instructions General The SYSTIMAX 360 360G2 4U rear access fiber optic combination shelf mounts

More information

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination 3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination Instructions IEEE Std. No. 48 Class 1 Termination CAUTION Working around energized electrical systems may

More information

Installing the Switch

Installing the Switch CHAPTER 3 Revised: January 4, 2012 This chapter describes how to install the Catalyst 4900M switch. For first-time installations, perform the procedures in the following sections in the order listed. Checking

More information

SJOF-BS604A Fiber Optic Splice Closure User Manual Rev.0

SJOF-BS604A Fiber Optic Splice Closure User Manual Rev.0 Fiber Optic Splice Closure VISSEM 1. Introduction 1.1 General VISSEM s SJOF-BS604A protects fiber optic splicing point in various installation conditions such as aerial, manholes, ducts, wall and direct

More information

COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure

COYOTE 9.5 x 19 (292 mm x 509 mm) Cross-Connect Dome Closure AUGUST 2013 COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED TM product

More information

Splice Only Sub Assembly. Follow all local safety regulations related to optical fibre plant elements

Splice Only Sub Assembly. Follow all local safety regulations related to optical fibre plant elements FIST-SOSA I N S T A L L A T I O N I N S T R U C T I O N Splice Only Sub Assembly Single element sub-assemblies Single circuit sub-assemblies Ribbon sub-assemblies FIST-SOSA-2SE8/2- X FIST-SOSA-4SC2/0-

More information

CORNING. CamSplice User Guide 2. TOOLS AN MATERIALS 1. GENERAL 3. LOADING CAMSPUCE INTO TOOL

CORNING. CamSplice User Guide 2. TOOLS AN MATERIALS 1. GENERAL 3. LOADING CAMSPUCE INTO TOOL CORNING CamSplice User Guide pin 006-038, Issue 13 1. GENERAL This procedure outlines the use of the Cam Splice and TKT-1 00-01 and TKT-100-02 tool kit for splicing optical fibers (see Table 1). This document

More information

LSS1U-144/7 FIBER OPTIC SPLICE SHELF INSTALLATION GENERAL CUSTOMER SERVICES REFERENCES TOOLS REQUIRED

LSS1U-144/7 FIBER OPTIC SPLICE SHELF INSTALLATION GENERAL CUSTOMER SERVICES REFERENCES TOOLS REQUIRED OFS Fitel LSS1U-144/7 Fiber Optic 636-99-103-1 Instruction Sheet Splice Shelf Installation COMCODE 845 866 474 LSS1U-144/7 FIBER OPTIC SPLICE SHELF INSTALLATION GENERAL This instruction sheet provides

More information

OFS LSS1U-864/ Instruction Sheet Fiber Optic Comcode: Splice Shelf Installation

OFS LSS1U-864/ Instruction Sheet Fiber Optic Comcode: Splice Shelf Installation OFS LSS1U-864/9 636-299-103-49 Instruction Sheet Fiber Optic Comcode: 848 461 620 Splice Shelf Installation LSS1U-864/9 FIBER OPTIC SPLICE SHELF INSTALLATION GENERAL This instruction sheet provides procedures

More information

CraftSmart Test Access Point (TAP) Box Installation Manual

CraftSmart Test Access Point (TAP) Box Installation Manual Installation Manual Installation Manual Table of Contents Application 3 Description 3 Technical Specifications 3 TAP Box Assembly 4 TAP Box Mounting 8 Cable Entrance 10 Grounding 11 Strength Member Clamp

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS GENERAL...2 SPECIFICATIONS...2 PACKAGE CONTENTS...2 PACKAGE CONTENTS: ACCESSORIES...3 REQUIRED TOOLS...3 ADD-ON COMPONENTS...3 CLOSURE MOUNTING...3 LOCK AND UNLOCK EXTERIOR DOOR...3 CABLE

More information

Access your fiber assemblies in the front of the enclosure to your fiber splices via a rear door without disturbing the fiber.

Access your fiber assemblies in the front of the enclosure to your fiber splices via a rear door without disturbing the fiber. Z Hinged Fiber Adapter Panel Enclosure Access your fiber assemblies in the front of the enclosure to your fiber splices via a rear door without disturbing the fiber. Customer Support Information Order

More information

Installation Instructions Part Number

Installation Instructions Part Number Installation Instructions Part Number 84152143 Thank you for choosing Chevrolet Performance as your high performance source. Chevrolet is committed to providing proven, innovative performance technology

More information

FOSC-100 B/H FOSC-100 B2/H

FOSC-100 B/H FOSC-100 B2/H FOSC-100 B/H FOSC-100 B2/H INSTALLATION INSTRUCTION TC-273-IP Rev A, Mar 2017 www.commscope.com Fiber Optic Splice Closure with integrated organizer system 1 1 General 1.1 The installation instruction

More information

3M No Polish Connector 8800-APC/AS SM SC/APC, Angle Splice, 250/900 µm Instructions

3M No Polish Connector 8800-APC/AS SM SC/APC, Angle Splice, 250/900 µm Instructions 3M No Polish Connector 8800-APC/AS SM SC/APC, Angle Splice, 250/900 µm Instructions February 2008 78-8140-1581-0 Contents 1.0 Summary...3 2.0 Connector Preparation...4 3.0 Fiber Preparation...4 4.0 Fiber

More information

COYOTE STP (Service Termination Point)

COYOTE STP (Service Termination Point) JANUARY 2017 COYOTE STP (Service Termination Point) Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.

More information

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit 3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit With High-K Stress Relief For 3-Conductor Copper Tape Shield Cables with or without Ground Wires 7600-T-3RJS Series Instructions

More information

COYOTE STP (Service Termination Point)

COYOTE STP (Service Termination Point) March 2019 COYOTE STP (Service Termination Point) Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED TM product before application.

More information

3M No Polish Connector 8800-APC/AS SM SC/APC, Angle Splice, 250/900-µm. Instructions. October C

3M No Polish Connector 8800-APC/AS SM SC/APC, Angle Splice, 250/900-µm. Instructions. October C 3M No Polish Connector 8800-APC/AS SM SC/APC, Angle Splice, 250/900-µm Instructions October 2010 78-8140-1581-0-C Contents 1.0 Summary...3 2.0 Connector Preparation...4 3.0 Fiber Preparation...4 4.0 Fiber

More information

Cabinet and Rack Installation

Cabinet and Rack Installation Cabinet and Rack Requirements, page 1 Cisco MDS 9000 Family Telco and EIA Shelf Bracket, page 3 Cabinet and Rack Requirements This section provides the Cisco MDS 9000 Family requirements for the following

More information

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL 854060 (USED FOR POWERING ENVIRONMENTAL ENCLOSURE MODELS MODELS 854030, 8535 AND 8537) OPERATION AND MAINTENANCE MANUAL P/N 6008416, REVISION C JUNE 2017

More information

Parts Manual H26 WALK BEHIND SCRUBBER

Parts Manual H26 WALK BEHIND SCRUBBER Parts Manual H26 WALK BEHIND SCRUBBER Introduction Preface Please be advised explicitly that we cannot accept any legal issues out of the contents of this manual. If repair work has to be performed make

More information

P. D. Q. Automatic Burnout Furnaces. 115 and 230-volt Models OPERATOR S MANUAL

P. D. Q. Automatic Burnout Furnaces. 115 and 230-volt Models OPERATOR S MANUAL P. D. Q. Automatic Burnout Furnaces 115 and 230-volt Models OPERATOR S MANUAL TABLE OF CONTENTS Introduction... 3 Warranty... 3 Safety Instructions........................................................

More information

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions SPC-P with Pyrotenax MI heating cable using required MI cable grounding kit SPC-P with Raychem

More information

Cabinet and Rack Installation

Cabinet and Rack Installation APPENDIXA This appendix includes the following information: Cabinet and Rack Requirements, page A-1 Cisco MDS 9000 Family Telco and EIA Shelf Bracket, page A-3 Cabinet and Rack Requirements This section

More information

JANUARY 2015 NOMENCLATURE. TOOLS REQUIRED 3/8" & 7/16" Can wrench or socket 1/4 Nut driver or screwdriver Snips Fiber optic cable opening tools

JANUARY 2015 NOMENCLATURE. TOOLS REQUIRED 3/8 & 7/16 Can wrench or socket 1/4 Nut driver or screwdriver Snips Fiber optic cable opening tools JANUARY 2015 COYOTE Dome Closure 6-1/2" x 17" Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED TM product before application. 1 2

More information

COYOTE Dome Closure 9.5" x 28" with Transition Tray for High Density Splice Applications

COYOTE Dome Closure 9.5 x 28 with Transition Tray for High Density Splice Applications OCTOBER 2017 COYOTE Dome Closure 9.5" x 28" with Transition Tray for High Density Splice Applications Be sure to read and completely understand this procedure before applying product. Be sure to select

More information

EasyStart Installation Instructions for Dometic Family RV A/Cs

EasyStart Installation Instructions for Dometic Family RV A/Cs EasyStart Installation Instructions for Dometic Family RV A/Cs DuoTherm Brisk Brisk II Penguin Penguin II Contents Introduction... 4 Safety first... 4 Making a good crimp... 4 Identifying Dometic AC Units...

More information

Copyright 2004 Alcatel. All rights reserved.

Copyright 2004 Alcatel. All rights reserved. Alcatel assumes no responsibility for the accuracy of the information presented, which is subject to change without notice. Alcatel, the Alcatel logo, MainStreet, and Newbridge are registered trademarks

More information

SITRANS F. Ultrasonic Flowmeters. Hi-Precision Mounts. Operating Instructions. Answers for industry.

SITRANS F. Ultrasonic Flowmeters. Hi-Precision Mounts. Operating Instructions. Answers for industry. SITRANS F Ultrasonic Flowmeters Hi-Precision Mounts Operating Instructions Edition 12/2014 Answers for industry. Preliminary Instructions 1 Reflect Mount Mode 2 SITRANS F Ultrasonic Flowmeters Hi-Precision

More information

Cabinet and Rack Installation

Cabinet and Rack Installation APPENDIXA This appendix provides information on how to install cabinet and rack, and includes the following sections: Cabinet and Rack Requirements, page A-1 Cisco MDS 9000 Family telco and EIA Shelf Bracket,

More information

Instructions for Preparing AFL OPTICAL GROUND WIRE CABLE (HEXACORE CABLE DESIGNS)

Instructions for Preparing AFL OPTICAL GROUND WIRE CABLE (HEXACORE CABLE DESIGNS) Instructions for Preparing AFL OPTICAL GROUND WIRE CABLE IN THE OPTI-GUARD SPLICE ENCLOSURE (HEXACORE CABLE DESIGNS) NOTE: EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT, THESE DRAWINGS AND/OR SPECIFICATIONS

More information

COYOTE LCC (Low Count Closure)

COYOTE LCC (Low Count Closure) PLP Feature Focus 2009 Preformed Line Products OCTOBER 2012 Film available at www.preformed.com COYOTE LCC (Low Count Closure) Be sure to read and completely understand this procedure before applying product.

More information

COYOTE Terminal Dome Closure 6.5" x 22"

COYOTE Terminal Dome Closure 6.5 x 22 FEBRUARY 2015 COYOTE Terminal Dome Closure 6.5" x 22" Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.

More information

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser INSTRUCTIONS-PARTS LIST 30 455 INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Rev. C Supercedes B Hand-Operated Portable Grease Dispenser Buckshot Luber

More information

Fiber Optic Splice Module

Fiber Optic Splice Module .COM 2016 O 24 Fiber Optice Splice Module in open position INSTALLATION INSTRUCTIONS Fiber Optic Splice Module Part Numbers: FHD-FOSMF, FHD-FOSMM 12 Fiber Optice Splice Module in open position Contents:

More information

TV Lift System Model L-75i Installation Instructions

TV Lift System Model L-75i Installation Instructions TV Lift System Model L-75i Installation Instructions Below is a parts list describing all of the items included with the Model L-75i Lift System. Contact: Support@Nexus21.com Toll Free: (866) 500-5438

More information

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION. THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION. DO NOT APPLY RTV TO THE GASKET WHEN SEALING THE SB01 SPLICE ENCLOSURE. SEE SECTION 10 FOR UPDATED INSTRUCTIONS.

More information

Cabinet and Rack Installation

Cabinet and Rack Installation APPENDIX A This appendix provides the following information: Cabinet and Rack Requirements, page A-1 Cisco MDS 9000 Family Telco and EIA Shelf Bracket, page A-4 Cabinet and Rack Requirements This section

More information

Instruction Sheet SRSR SERIES. Rotating Sliding Rail System

Instruction Sheet SRSR SERIES. Rotating Sliding Rail System Instruction Sheet SRSR SERIES Rotating Sliding Rail System THANK YOU Thank you for purchasing the SRSR Series Rotating Sliding Rail System. Please read these instructions thoroughly before assembling this

More information

OPTICAL FIBER CLOSURE

OPTICAL FIBER CLOSURE OPTICAL FIBER CLOSURE INSTALLATION MANUAL STC-HTM Read these instructions carefully and completely before beginning installation. For assistance, contact Technical Support at 82.61.373.7500(South Korea),

More information

2-row and All-row systems included.

2-row and All-row systems included. Ag Leader Technology Cotton Picker Installation Installation Instructions for John Deere cotton picker models: 2-row and All-row systems included. IMPORTANT: Ensure the model numbers shown above correspond

More information

Instructions for 2-row monitoring only

Instructions for 2-row monitoring only Installation Instructions for CaseIH cotton picker models: Instructions for 2-row monitoring only CAUTION: Ensure the model numbers shown above correspond to the machine model. If you receive the incorrect

More information

Fiber Optic Illuminator. Model 21AC Model 21DC

Fiber Optic Illuminator. Model 21AC Model 21DC Operation Manual Fiber Optic Illuminator Model 21AC Model 21DC Warning This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may

More information

Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) OT-8903-AE. Installation Manual

Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) OT-8903-AE. Installation Manual Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) OT-8903-AE Installation Manual 1. Scope of application This Installation Manual suits for one of the Fiber Optic Splice Closure (Hereafter abbreviated

More information

19 floor rack with steel door

19 floor rack with steel door 2015 Telecommunication rack systems HETEL 1 19 floor rack with steel door Rack width 600 mm Rack width 800mm General features include a metal frame, 19 rails, roof, side and rear panels, door and plinth

More information

Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.

Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application. 5 NOVEMBER 2010 COYOTE Dome 9.5 x 28 Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application. 1. 7. 2. 4. 10.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Accessory Application Publications No. SYSTEM 2005 ACCORD All 27511 (DX, LX) 2-AND 4-DOOR Issue Date AUG 2004 PARTS LIST Security System Attachment (LX): P/N 08E55-SDA-100A Unit

More information

MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits

MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits MARCH 2012 COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before

More information

E Series Enclosures Installation Instructions (UL /UL2416 E Series Equipment Cabinet/Rack)

E Series Enclosures Installation Instructions (UL /UL2416 E Series Equipment Cabinet/Rack) E Series Enclosures Installation Instructions (UL60950-1/UL2416 E Series Equipment Cabinet/Rack) WeRackYourWorld.com 1-866-TRY-GLCC (879-4522) Instructions for the following Great Lakes Enclosures: GL720E-2432,

More information

Instructions for 2-row monitoring only

Instructions for 2-row monitoring only Installation Instructions for CaseIH cotton picker models: Instructions for 2-row monitoring only Ensure the model numbers shown above correspond to the machine model. If you receive the incorrect installation