LABOR ASTER INDUSTRIAL AUTOMATION. Intrinsically safe barrier with separation FIELDBUS TRANSMISSION LINES CONVERTER-SEPARATOR

Size: px
Start display at page:

Download "LABOR ASTER INDUSTRIAL AUTOMATION. Intrinsically safe barrier with separation FIELDBUS TRANSMISSION LINES CONVERTER-SEPARATOR"

Transcription

1 LOR STER INDUSTRIL UTOMTION Intrinsically safe barrier with separation FIELDUS TRNSMISSION LINES CONVERTER-SEPRTOR type SEx-RS RS/RS, RS/, /RS, /, RS/RS - group I, category M and group II and III, category accompanying device - Intrinsically safe input circuit of ia protection level TEX compliance - EC-Type Examination Certificate: KD 0TEX0 FETURE: II () G [Ex ia] IIC, II ()D [Ex ia] IIIC, I (M) [Ex ia] I, II G Ex n II T TEX ox Protection level IP0 Operating temperature range C - Intrinsically safe circuit can operate with transmission line led to explosion hazardous zone 0,,, 0,, of any explosive mixtures. - The second separated transmission side and supply circuit can work with non-intrinsically safe circuits of devices with voltage Um=V e.g. supplied from 0Vac network. - The separator as accompanying device should be installed in explosion safe zone or in explosion hazardous zone in suitable explosion-proof designed enclosure (see page ). tmosphere should be dry, dust free and protected against access of people not trained in maintenance and operation of the separator. - The separator can be installed in explosion hazardous zone in,,, in flameproof enclosure Ex d or encapsulated Ex m. In zone basing on marking Ex n II T (category device) it can be installed in other enclosure in accordance with rules in force (e.g. Ex e between others) see page. Separation and translation of the following transmissions: Safe zone Explosion hazardous zone RS RS RS RS RS The separator is designed between others for MODUS RTU/SCII, PROFIUS DP and operates correctly with any half-duplex protocol. audrate 0 00 bd. Smart control of flow direction. ll circuits fully galvanically separated. Internal lines terminators. Led indication of supply, transmission and line damage. PURPOSE : The separator is designed to galvanically separate and translate transmission standards RS, RS, in safe zone to standards RS or in intrinsically safe circuit leading to hazardous zone. For RS and transmission the separator allows to extend the transmission line up to 00 meters (up to 00 meters for baudrate 00) and many devices to operate with each other. Separation eliminates interferences and the differences of potentials. It also protects connected devices from power surges. The change in transmission type ( to RS or vice versa) is done through appropriate connection of transmission wires to the terminals and possible connection of the terminator. Changing the input type to RS requires opening of the housing and switching the jumpers. Switching description is given later in this document. audrate RS/ connection line length 00 - < 00 m 00 - <000m < 00 - <00m SIC TECHNICL PRMETERS: Non-intrinsically safe side RS according to RSC standard Receiver parameters: - low level - - V - V - high level - + V + V Connection line length - max m (00) (capacity sum C 00pF), max m (00 C<00pF) Transmitter parameters: - output voltage - minimum V on load R k RS and - receiver sensitivity - 0. V - signal from transmitter - min V on load R 00 Connection line length - max 00m audrate - 0 to 00 bd Minimal interval between - length of character switching Direction of line switching - <0 ns time Distortion of the bit - <00 ns Phase shift of the bit - <00 ns Number of devices in the line - max Supply indication - PWR LED on (blinking indicates a constant state of 0 on one of lines) Transmission indication - RS LED on Supply Vdc/0m Rail housing IP0 - on TS rail Galvanic separation - circuits of both sides of transmission and supply circuit mutually separated - isolation test voltage - kv 0Hz Rail housing IP0 - with rail. x x.mm EMC requirements - PN-EN 000--, PN-EN Safety requirements - PN-EN 00-:00 The device during production is tested for speed 00k. t speeds higher than 00 gate switching time may increase to bytes.

2 HRDOUS ONE + - V 0 T- RS() Pwr RS SEx-RS hazardous zone 0,,, 0,, RS() T- RS RS 0 T- J SFE ONE Vdc + - T- T- RS T- View of the front side of the SEx-RS separator lock diagram of the SEx-RS separator Housing dimensions: thickness. mm; width mm, height. mm. NOTE: Terminal GND in intrinsically safe circuit allows connecting shield of the transmission cable which goes to explosion hazardous zone. raid of the shielded cable cannot be grounded from both sides (in safe zone and hazardous zone). raid does not have to but can be connected to the ground but only from one side. If GND terminal together with cable shield is grounded in safe zone then braid of the cable in explosion hazardous zone must be distanced minimum cm from terminals of the core of this cable. View of the jumpers comb to switch. Description of the jumpers configuration is in the table on page. THE SFET PRMETERS: directive TEX - PN-EN 00-0:0, PN-EN 00-:0 a) Intrinsically safe circuit: terminals T-,,, T-,,, GND with ia protection level: Distributed values of Co, Lo, L/R of the connection cable should be adopted according to the table shown below. L/R [mh/ ] Lo [mh] Co [ F] Uo [V] Io [m] Po [mw] Version I and II and I and II and I and II and IIC IIC II III II III II III IIC SEx-RS-, 0, 0,0 0, SEx-RS-, 0, 0,0 0, SEx-RS-, 0, 0, 0, SEx-RS-,0 0,0 0,,, SEx-RS- 0,0 0, 0,, 0, Characteristic of the circuits is linear. For clustered values should be taken half of the values of Co, Lo given in this table remembering that Co cannot exceed µf for group I, II, II and 0,µF for IIC. b) Intrinsically safe circuit parameters: terminals T-,,, T-,,, GND with ia protection level: Li 0, Ci 0. Version Ui [V] Ii [m] SEx-RS- SEx-RS- 0 SEx-RS- 0 0 SEx-RS- 0 SEx-RS- 0 Pi [mw] does not require determination c) Non-intrinsically safe circuits parameters: terminals,, T-,, and supply V : terminals S+, S- : Safety parameters for group III (dusts) are the same as for group II (gas). Um=V

3 In installations in which parameters Ci and Li of device cooperating with intrinsically safe circuit (connection cable excluded) exceeds % of the value of parameters Co and Lo given in the table above you should: - from 0% of the value of Co, Lo subtract Ci, Li of cooperating device, - these values remains for parameters of connection cable, - if cable parameters are unknown you can take 00pF/m, 0,µH/m for calculation. Conditions of use: Typical application for the separator is to be installed in safe zone. The separator can be installed in explosion hazardous zone in flameproof enclosure (or other in accordance with the rules in force). pplication in first (I) explosive group does not require putting warning on the enclosure. fter turning off the supply it can be taken out of the enclosure without delay. In case of using it in II and III explosive group, on outer part of the enclosure must be warning: "Do not open the enclosure within 0 minutes after turning off the power". For installation in zone : The separator can be installed in explosion-proof design enclosure e.g. with protection level Ex n or Ex e, Ex c, ensuring at least IP. The enclosure should have cable inputs and blanking elements meeting the same requirements of protection level Ex n or Ex e, Ex c. To prevent self-loosing of cables in non-intrinsically safe screw terminals number, 0,,,,,, should be used not-tinned cables: - single wire or braid wire with twisted ending with diameter of 0.. mm², - braid wires with the same diameter of 0.. mm² with twisted ending put together to common tubular sleeve kniked with special tool. Terminals should be tighten with a torque of 0. Nm with a flathead screwdriver having a width of.0... mm. Every months terminals should be checked and tighten with a torque of 0. Nm with a flathead screwdriver having a width of.0... mm. Note: When there is or may be explosion atmosphere, it is not allowed to connect voltage cables to non-intrinsically safe terminals number, 0,,,,,,. When the device is powered, it is not allowed to connect or disconnect cables in non-intrinsically safe circuits. When there is or may be explosion atmosphere during service operations power supply should be disconnected in safe zone. efore starting service operations non-explosion atmosphere should be ensured when the separation is installed in zone. FUNCTIONL DESTRIPTION The device continuously monitors the transmission speed and adjusts its operation to the actual speed. It uses the innovate algorithm testing transmission speed developed by LOR-STER company in result there is no need for constant speed or direction of the transmission. characteristic feature of this algorithm is lack of any information loss at the start of the transmission with any speed. It is suited specifically to Modbus SCII/RTU protocol, but works correctly in each half-duplex protocol (e.g. PROFIUS DP). Only requirement is the continuity of transmission and minimal pauses between changing the direction of the transmission. ny errors are indicated via LEDs. PWR LED is continuously lit after turning on power supply or blinks when it detects low state lasting longer than about 0, sec. (which proves mostly of incorrect polarity of the transmission line to change it please disconnect the line, wait for LED is not blinking anymore and then connect again correctly). RS LED is lit during transmission on one of the two lines.

4 Configuration of the device. The separator is equipped with optional attached internal 00Ω terminators matching the wave resistance of the line. fter opening the housing can be set: Description of the jumpers configuration. Shorting enables transmission direction control on the side of the intrinsically safe circuit (ex hazardous zone side). Opening disables transmission control. Transmitter is permanently switched on. Shorting echo block Opening echo block circuit is switched off Shorting enables transmission direction control on the side of the safe zone. Opening disables transmission control. Transmitter is permanently switched on. Opening when RS Shorting input standard from safe zone is RS. Opening input standard RS/. Shorting direction switching delay by additional byte. Recommended for discontinuous transmission. Opening usual direction switching delay (after one byte of silence). Description of the jumpers configuration. - Shorting connects the internal terminator to / line. Opening disconnects the terminator of / line Configuration jumpers storage. Safe side Device connecting description External connecting description RS RS SW - short. SW - open. SW - short SW - open SW - short SW - open SW - short (open option) SW - (short option for terminator) D Female (example) TxD D- RxD D- GND D- short with signal of RS line short with signal of RS line (optionally T- connected to internal terminator) signal, signal (optionally T- connected to internal terminator) signal, signal Hazardous side RS RS Device connecting description SW - short SW - short (open option) External connecting description short with signal of RS line short with signal of RS line (optionally T- connected to internal terminator) signal, signal (optionally T- connected to internal terminator) signal, signal (optionally T- connected to internal terminator)

5 Example of use of terminators Connecting without noise filter Connecting with noise filter. Only on the safe zone. Use in case of interference generators nearby e.g. high power electric engines, turbine, induction furnace. It can be ordered from LOR-STER after consultancy. C RT RT RT RT RT RT C C * * audrate* R T audrate transmission speed in bods. ORDERING CODE: Converter-separator type SEx-RS---X where =(,,,, ) according to the table from page (column Version ). Safe zone - EX zone - X RS without echo - RS echo - RS C C half-duplex D D half-duplex with terminator E - full-duplex F F Production and distribution: LOR STER Poland, 0 Warsaw, ul. Czechowicka tel ; + 0 ; fax E- mail: biuro@labor-automatyka.pl http: The manufacturer reserves the right to make changes to the product Edit. 0 / 0 In this version (FF) the device does not control transmission direction. The same is in F configuration.

6 SEx-RS---C SEx-RS- --C Detailed description of connection and configuration of each version. elow description concerns ordered version and its connection. User can change his device version basing on below drawings (after demounting it and opening the housing). Most popular versions are marked on green. During inactive state of transmission lines have positive voltage in relation to their equivalent while voltmeter is between transmission terminals (couples:,,, ). Connection between SEx-RS and master computer in version with RS- interface for two types of connectors. SEx-RS GND RxD TxD SEx-RS RxDTxD GND Dotted line is for optional connections. D-F D-M Code Description Jumpers description Hazardous zone Connection drawing Safe zone RS RxD RS RS RS Transmission with echo suppression. Half-duplex transmission. - shorted - shorted - shorted T- T- TxD + Vdc - RS RxD RS RS RS Transmission with echo. Half-duplex transmission. Wrong echo indicates a conflict in the RS- line. - shorted - shorted T- T- TxD + Vdc - Jumper - should be used in case of discontinuous transmission. This jumper does not affect function of the device described in the table. In this case parameter concerns intrinsically safe version =(,,,, ) and was described in the table on page ( Version column). This jumper does not affect function of the device described in the table.

7 SEx-RS---F SEx-RS---D SEx-RS---D Code Description Jumpers description Hazardous zone Connection drawing Safe zone RxD RS RS receiving, transmitting. Transmission with echo suppression. transmission half-duplex with releasing lines. always receive and is correlated with TxD, and transmits and is correlated with RxD. - shorted - shorted - shorted T- T- TxD + Vdc - RxD RS RS receiving, transmitting. Transmission with lines control. transmission halfduplex with releasing lines. Echo occurrence indicates wrong configuration of line (shorted) or conflict. - shorted - shorted T- T- TxD + Vdc - RxD RS RS, receiving, transmitting. Transmission with echo suppression. transmission full-duplex without direction control. Device is transparent for transmission. always receive and is correlated with TxD, and transmits and is correlated with RxD. - shorted - shorted T- T- TxD + Vdc -

8 SEx-RS--C-D SEx-RS--C-C SEx-RS---F Code Description Jumpers description Hazardous zone Connection drawing Safe zone RS, receiving, transmitting. Transmitting with echo. Echo occurrence indicates shortage error of lines -, -. transmission full-duplex without direction control. Device is transparent for transmission. always receive and is correlated with TxD, and transmits and is correlated with RxD - shorted T- T- RxD TxD RS + Vdc - RS RS RS RS Transmission half-duplex with all direction control. - shorted - shorted T- T- T- 0 + Vdc - RS RS receiving, transmitting. transmission half-duplex with releasing lines. - shorted - shorted T- T- T- 0 + Vdc -

9 SEx-RS--E-C SEx-RS--D-C SEx-RS--C-F Code Description Jumpers description Hazardous zone Connection drawing Safe zone RS RS, receiving, transmitting. transmission half-duplex without direction control. always receive and always transmit. - shorted T- T- T- 0 + Vdc - RS RS, receiving, transmitting. Transmission half-duplex with all transmission direction control. No terminators from safe side. - shorted - shorted T- T- T- 0 + Vdc - RS RS, receiving, transmitting. Transmission half-duplex with all transmission direction control. Terminators from safe zone. - shorted - shorted - shorted T- T- T- 0 + Vdc -

10 SEx-RS--D-F SEx-RS--D-D SEx-RS--F-C Code Description Jumpers description Hazardous zone Connection drawing Safe zone RS RS receiving, transmitting. Transmission half-duplex with only and control from intrinsically safe side. Lines are turning off if no transmission. Lines and transmitting all the time. Terminators from safe zone. - shorted - shorted T- T- T- 0 + Vdc - receiving, transmitting. Transmission half-duplex with all transmission direction control.. Lines are turning off if no transmission. No terminators from safe side. - shorted - shorted T- T- T- 0 + Vdc - receiving, transmitting. Transmission half-duplex with only and control from safe side. Lines are turning off if no transmission. Lines and transmitting all the time. No terminators from safe side. - shorted T- T- T- 0 + Vdc -

11 SEx-RS--F-D SEx-RS--E-F SEx-RS--E-D Code Description Jumpers description Hazardous zone Connection drawing Safe zone receiving, transmitting. Transmission half-duplex with all transmission direction control. Lines are turning off in no transmission. Terminators from safe side. - shorted - shorted - shorted T- T- T- 0 + Vdc - receiving, transmitting. Transmission half-duplex with only and control from safe side. Lines are turning off if no transmission. Lines and transmitting all the time. Terminators from safe side. - shorted - shorted T- T- T- 0 + Vdc - receiving, transmitting. Transmission full duplex with only and control from intrinsically safe side. Lines are turning off if no transmission. Lines and transmitting all the time. Terminators from safe side. - shorted - shorted T- T- T- 0 + Vdc -

12 SEx-RS--F-F Code Description Jumpers description Hazardous zone Connection drawing Safe zone receiving, transmitting. Transmission full duplex without direction control. Lines transmitting all the time. Terminators from safe side. are correlated with lines, and with lines and. - shorted T- T- T- 0 + Vdc - Production and distribution: LOR STER Poland, 0 Warsaw, ul. Czechowicka tel ; + 0 ; fax E- mail: biuro@labor-automatyka.pl http: The manufacturer reserves the right to make changes to the product Edit. 0 / 0

LABOR ASTER INDUSTRIAL AUTOMATION. Intrinsically safe barrier with separation FIELDBUS TRANSMISSION LINES CONVERTER-SEPARATOR

LABOR ASTER INDUSTRIAL AUTOMATION. Intrinsically safe barrier with separation FIELDBUS TRANSMISSION LINES CONVERTER-SEPARATOR LOR STER INDUSTRIL UTOMTION Intrinsically safe barrier with separation FIELDUS TRNSMISSION LINES CONVERTER-SEPRTOR type SEx-RS-[ic] RS/RS, RS/, /RS, /, RS/RS - group II and III, category () accompanying

More information

RVP-R- VAV controller. In explosion-proof version

RVP-R- VAV controller. In explosion-proof version VAV controller In explosion-proof version RVP-R- SMAY LLC / 29 Ciep³ownicza St. / 31-587 Cracow / Poland tel. +48 12 378 18 00 / fax. +48 12 378 18 88 / e-mail: info@smay.eu Intended use VAV control units

More information

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Technical brochure Features Ex ll 1G EEx ia llc T4 - T6 in compliance with ATEX 100a Applicable

More information

Holville I.S. Uninterruptible Power Supply Unit (UPS)

Holville I.S. Uninterruptible Power Supply Unit (UPS) Holville I.S. Uninterruptible Power Supply Unit (UPS) The Holville range of intrinsically safe equipment has power outputs specifically designed for use in Group 1 hazardous areas. The range includes Compact

More information

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1 INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70054084 Issued to: Emerson - Rosemount, Micro Motion Inc. 12001 Technology Dr. Eden Prairie, Minnesota 55344 USA Attention: Paul Schilke The products listed below

More information

PPT 802, Proximity Probe Transducer System

PPT 802, Proximity Probe Transducer System PPT 802, Proximity Probe Transducer System PPH 080 : Proximity Probe Head PEC 036 : Probe Extension Cable PRD 020 : Proximity Probe Driver Feature Non-contacting measurement system based on eddy current

More information

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application 2-3.1 ATC 510/520/525 for wall-mounting Application The ATC 510/5205/525 is a modern microprocessor-based (PID) control device featuring easy handling and a digital display. The clear design of the operator

More information

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION 1. GENERAL INFORMATION The MICROSOL intrinsic safety solenoid valves produced by Fluid Automation Systems SA are dedicated to piloting fluids in explosive atmospheres according to the ATEX 94/9/CE directive,

More information

ECONOMISER SERIES E2T USER MANUAL

ECONOMISER SERIES E2T USER MANUAL TURBO S.R.L. Electronic Control Systems for Dust Collectors e-mail: info@turbocontrols.it web: www.turbocontrols.it TEL. ++39 (0)362 574024 FAX ++39 (0)362 574092 ECONOMISER SERIES E2T USER MANUAL 24/06/2014

More information

Data Sheet SCHISCHEK EXCOS-P. Pressure sensor 20 Pa Pa. Supplied by. .com. Call us on +44 (0)

Data Sheet SCHISCHEK EXCOS-P. Pressure sensor 20 Pa Pa. Supplied by. .com. Call us on +44 (0) Data Sheet SCHISCHEK EXCOS-P Pressure sensor 20 Pa... 7.500 Pa Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com ExCos-P Pressure sensor 20 Pa... 7.500 Pa Electrical, explosion-proof

More information

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0. DMK P Industrial Pressure Transmitter Pressure Ports With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 60 bar up to 0... 400 bar Output signals

More information

Fuse state indicator MEg72. User manual

Fuse state indicator MEg72. User manual Fuse state indicator MEg72 User manual MEg Měřící Energetické paráty, a.s. 664 31 Česká 390 Czech Republic Fuse state indicator MEg72 User manual Fuse state indicator MEg72 INTRODUCTION The fuse state

More information

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm Industrial Pressure Transmitter Pressure Ports With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 60 bar up to 0... 400 bar Output signals

More information

707Ex. Users Manual. ma Calibrator

707Ex. Users Manual. ma Calibrator 707Ex ma Calibrator Users Manual March 2003 Rev 2 3/03(English) 2003 Fluke Corporation, All rights reserved. Printed in USA All product names are trademarks of their respective companies. Table of Contents

More information

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO. Process Pressure Transmitter with HART -communication Ceramic Sensor accuracy according to IEC 60770: 0.1 % FSO Nominal pressure from 0... 160 mbar up to 0... 20 bar Output signals 2-wire:... 20 ma others

More information

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22. PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22 News 08 PROTECT SRB s Safety relay modules with intrinsically safe monitoring

More information

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter. TEMATEC GmbH Postal address:: Postbox 6 House address Löhestr. 7 5759 Hennef 577 Hennef Fon (+49) 0 4-87 0-0 Fax (+49) 0 4-87 0-0 http: // www.tematec.de e-mail: team@ tematec.de TEMATEC GmbH Data Sheet

More information

PHOENIX CONTACT - 01/2008

PHOENIX CONTACT - 01/2008 Exi Solenoid Driver, With Intrinsically Safe Output, LoopPowered, TwoChannel INTERFACE Data Sheet 0289_00_en PHOENIX CONTACT 0/2008 Description The PIEXME2SD/24/65C is a twochannel solenoid driver. It

More information

ILED Dorado. User Manual

ILED Dorado. User Manual 10NM U-code Medium Intensity Obstruction Light Helideck Status Light 15NM U-code Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 4. Product Description...

More information

EXAMINATION CERTIFICATE

EXAMINATION CERTIFICATE CGT-02 KDB 04ATEX036 English translation CERTIFICATE [1] EC TYPE EXAMINATION CERTIFICATE [2] Devices, protection systems, parts and sub-assemblies for explosion hazardous areas. Directive 94/9/EC (introduced

More information

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve Ex d Ex m IP5 Series 3 Way Direct Acting Balanced Poppet Solenoid Valve DB2S-M2C \ Ex d IIC with Integral Stainless \ Steel Junction Box. \ Valve. \ Manual Override, Option M2. J77072S-M2 \ Ex m II NASS

More information

EZ-LIGHT K30L and K50L Intrinsically Safe Indicators

EZ-LIGHT K30L and K50L Intrinsically Safe Indicators For use in hazardous areas with suitable zener barriers or galvanic isolators ATEX and IECEx certifications Fully sealed and rated to IP67/IP69K 1-, 2-, or 3-color models available; 5 available colors

More information

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO from 0... 00 mbar up

More information

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Industrial

More information

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo Explosion-proof Solenoids II 2 G / II 2 D EEx dm IIC T4, T5, T6 Catalogue Maximum photo ATEX Explosionproof solenoids with flameproof enclosure/encapsulation "dm" According to ATEX directive 94/9/EC and

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 40

More information

Endress+Hauser Wetzer GmbH+Co. KG Obere Wank Nesselwang Germany. Field Temperature Transmitter itemp, Types TMT82, TMT84 and TMT85

Endress+Hauser Wetzer GmbH+Co. KG Obere Wank Nesselwang Germany. Field Temperature Transmitter itemp, Types TMT82, TMT84 and TMT85 --~---- - ECEx Certificate NTERNATONAL ELECTROTECHNCAL COMMSSON EC Certification Scheme for Explosive Atmospheres for rules and details of the ECEx Scheme visit www.iecex.com ECEx DEK 11.0096 issue No.:O!

More information

LMK 387. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO

LMK 387. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO LMK 87 Stainless Steel Probe Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... mho up to 0... 00 mho Output signal -wire: 4... 0 ma Special

More information

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2 Fieldbus Segment Protector Features Assembly 4... 10 outputs Ex ic (FISCO or Entity) or non-incendive (Div 2) Advanced fault isolation at the spur Segment Protector in Zone 2/Div. 2 Instruments in Zone

More information

INTERNATIONAL METAL ENGINEERING

INTERNATIONAL METAL ENGINEERING INDICATING TEMPERATURE TRANSMITTER WITH HART 8080HT UNIVERSAL SETTINGS WITH HART PROTOCOL FOR VARIOUS INPUT SIGNALS 2 WIRE TECHNOLOGY, 4 TO 20mA ANALOG OUTPUT HIGH ACCURACY IN TOTAL AMBIENT TEMPERATURE

More information

General Specifications

General Specifications General Specifications Model RAGG Rotameter This type of Rotameter is designed for measurement of liquids and gases. The conical glass metering tube has a free rotating float. This float is mounted in

More information

Model TUR-200D Turbine Flowmeter

Model TUR-200D Turbine Flowmeter General Specifications Model TUR-200D Turbine Flowmeter Liquid flows through the turbine housing causing an internal rotor to spin. As the rotor spins, an electrical signal is generated in the pickup coil.

More information

Rosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications

Rosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications Product Data Sheet Rosemount 3051 FIELDBUS PROTOCOL Hazardous Locations Certifications North American Certifications FM Approvals E5 Explosion-Proof for Class I, Division 1, Groups B, C, and D. Dust-Ignition-Proof

More information

FasTrak High Capacity Smart Positioner

FasTrak High Capacity Smart Positioner FasTrak High Capacity Smart Positioner 2 CCI provides the next level of control valve performance CCI provides the next level of control valve performance with FasTrak, a high capacity digital positioner

More information

Operating Instructions. Angle Seat Control Valve. Type 7020

Operating Instructions. Angle Seat Control Valve. Type 7020 Operating Instructions Angle Seat Control Valve Type 7020 With: Digital Positioner Type 8048 Electro-pneumatic Positioner Type 8047 Pneumatic Positioner Type 8047 Version: 02/2006 Manual-7020e.doc Art.-No:

More information

RAE PowerPak User s Guide

RAE PowerPak User s Guide RAE PowerPak User s Guide \\\\\ Rev. A July 2009 P/N F03-4001-000 Copyright 2009 RAE Systems, Inc. Ordering Replacement Parts: If you need replacement parts, a list is available online: http://www.raesystems.com

More information

WBS 3000 Water Bottom Sensor for fuel oil and chemical storage tanks Installation and Operating Instructions

WBS 3000 Water Bottom Sensor for fuel oil and chemical storage tanks Installation and Operating Instructions Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 12.3.2013 Internet: www.labkotec.com 1/12 WBS 3000 Water Bottom Sensor for fuel oil and chemical storage

More information

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc 900/77-80-094-001 158877 For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more compact, space-saving

More information

SATRON VT Pressure Transmitter

SATRON VT Pressure Transmitter SATRON VT pressure transmitter belongs to the series V-transmitters. SATRON VT is used for 0-1.4 kpa...0-100 MPa ranges. It is a 2-wire transmitter with HART standard communication. In pressure measuring

More information

Smart Valve Positioner 700 Series with HART Communication Protocol

Smart Valve Positioner 700 Series with HART Communication Protocol No. SS2-AVP702-0100 Smart Valve Positioner 700 Series with HART Communication Protocol OVERVIEW The Smart Valve Positioner 700 Series (model number: AVP7**) not only inherits the reliability of the core

More information

ExBin-P Pressure switches 5 Pa Pa

ExBin-P Pressure switches 5 Pa Pa ExBin-P Pressure switches 5 Pa... 5.000 Pa Electrical, explosion-proof binary pressure / differential pressure switches 5 Pa...100 Pa with adjustable switch activation delay 24 VAC/DC supply voltage, potential

More information

Point level measurement Capacitance switches

Point level measurement Capacitance switches Pointek CLS300 Standard Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output.

More information

Level limit switch Series RF 3000 Selection list

Level limit switch Series RF 3000 Selection list Table of content Page Overview P2 Applications P4 ------------------------------------------------------------------------------------------------------------- RF 3100 Standard version P6 -------------------------------------------------------------------------------------------------------------

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 044 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000 racket

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry TEX Compliant Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 44 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000

More information

Smart Valve Positioner 700 Series with HART Communication Protocol

Smart Valve Positioner 700 Series with HART Communication Protocol No. SS2-AVP702-0100 Smart Valve Positioner 700 Series with HART Communication Protocol OVERVIEW The Smart Valve Positioner 700 Series (model number: AVP7**) not only inherits the reliability of the core

More information

The filling level sensors are designed in accordance to the following standards

The filling level sensors are designed in accordance to the following standards Instructions according to Portaria N 179/2010 UL-BR 17.0706 Filling Level Sensors type VISY-Stick and type TORRIX Ex Version: 09.2017 I Range of application The filling level sensors are designed for continuous

More information

Ex Instruction manual. Rotamass Coriolis mass flow meter. IM 01U10X03-00EN-R, 1st edition, Rev FM-1

Ex Instruction manual. Rotamass Coriolis mass flow meter. IM 01U10X03-00EN-R, 1st edition, Rev FM-1 Ex Instruction manual Rotamass Coriolis mass flow meter IM 01U10X03-00EN-R, 1st edition, 2017-02-08 Rev -1 Table of contents Table of contents 1 Introduction... 3 1.1 Scope of application... 3 1.2 Applicable

More information

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3 Operating Instructions Pneumatic Control Valve Low Temperature Type 8026 Series GS3 With: Digital Positioner Type 8048 Electro-pneumatic Positioner Type 8047 Pneumatic Positioner Type 8047 Version: 03/2006

More information

EG Series Installation Manual

EG Series Installation Manual EG Series Installation Manual Convenient Micro Connectors (M) speed installation and maintenance Enclosure is fully potted and sealed to eliminate threat of moisture contamination in the wiring and electronics

More information

USERS MANUAL MCD REMOTE OPERATOR

USERS MANUAL MCD REMOTE OPERATOR USERS MANUAL MCD REMOTE OPERATOR Order Code: 175G9004, 175G3061 Contents Contents Introduction...2 Important User Information...2 General Description...2 Symbols Used in this Manual...2 Installation...3

More information

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX )

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX ) LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX ) Publication# 03revA Table of Contents Publication# 03revA Table Of Contents...

More information

System Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters

System Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters System 6000 Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters Edition April 2018 Information Sheet T 6000 EN Electropneumatic Converters i/p converters

More information

Capacitive level sensors CLS 23

Capacitive level sensors CLS 23 For level detection of electrically conductive and non-conductive liquids Compact miniature performance for direct mounting to vessels, tanks, sumps and tubes Easy setting by means of magnetic pen SIL

More information

SATRON VDt Differential Pressure Transmitter

SATRON VDt Differential Pressure Transmitter SATRON VDt differential pressure transmitter belongs to V-transmitter family. The series V transmitters have both analog and smart properties. SATRON VDt is used for -,1kPa...-15 MPa ranges. It is a 2-wire

More information

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial TEMATEC GmbH Postal address: House address Fon (+49) 0 4-870-0 Postbox 6 Löhestr. 7 Fax (+49) 0 4-870-0 http: // www.tematec.de 5759 Hennef 577 Hennef e-mail: team@tematec.de TEMATEC GmbH Data Sheet DMP

More information

Lexium integrated drives

Lexium integrated drives Description ILp for CANopen, PROFIBUS DP, RS ILE with brushless DC motor Description ILE comprise control electronics with a fieldbus interface for CANopen DS, PROFIBUS DP or RS and a brushless DC motor.

More information

Category II 1 G only applies to the Constructional Variants shown in table 15.2 of annex 1.

Category II 1 G only applies to the Constructional Variants shown in table 15.2 of annex 1. (13) SCHEDULE (14) to EC- Examination Certificate KEMA 04ATEX1152 X Issue No. 5 (15) Description Two Wire Proximity Sensors with digital output signal...-.-.ay1..-.. /. and...-.-.ry1..-.. /. are used for

More information

Rosemount 3095FT MultiVariable Flow Data Logger

Rosemount 3095FT MultiVariable Flow Data Logger Quick Installation Guide Rosemount 3095FT Rosemount 3095FT MultiVariable Flow Data Logger Step 1: Mount the Transmitter Step 2: Consider Housing Rotation Step 3: Set Jumpers and Switches Step 4: Connect

More information

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram Data Sheet 403025 Page 1/10 JUMO dtrans p20 Process pressure transmitter Brief description The JUMO dtrans p20 pressure transmitter with HART interface combines maximum precision with easy operation. It

More information

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications Explosion Proof Adjustable Flow Switch with Right Angle Flow Key Features Field adjustable Infinite flow range Extremely accurate and sensitive Low pressure drop UL recognized for hazardous location ATEX

More information

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module Electrical temperature measurement Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module WIKA data sheet TE 60.17 for further approvals see page 6 Applications

More information

CAPACITANCE LEVEL SWITCH

CAPACITANCE LEVEL SWITCH CAPACITANCE LEVEL SWITCH http: //www.fine-tek.com e-mail: info@fine-tek.com Tel: 886--696789 Fax: 886--68668 4 PRINCIPLE The capacitance level switch measuring principle is based on the "capacitance effects".

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals ABB MEASUREMENT & ANALYTICS DATA SHEET TEIP11 I/P signal converter for standard signals 2 TEIP11 I/P SIGNAL CONVERTER FOR STANDARD SIGNALS DS/TEIP11-EN REV. D Flow in air pressure Proven and reliable concept

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en 00 / poppet valves electromagnetic actuated, directly controlled, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 8, DIN V Valves for safety systems up to SIL Solenoid valve also suitable

More information

Level Measurement Continuous level measurement - Capacitance transmitters

Level Measurement Continuous level measurement - Capacitance transmitters Overview Probe Applications Rod version Rod version with stilling well Cable version PFA coated cable version Extended cable with rod version Conductive liquids, slurries or solids Conductive liquids or

More information

Body: Seat disc: Anod. aluminium body NBR. Connection / Orifice Flow factors Temperature values ( C)

Body: Seat disc: Anod. aluminium body NBR. Connection / Orifice Flow factors Temperature values ( C) Parker Lucifer Data Sheet 22062004 General information Lucifer ref.: 341N31 Global ref.: 7341NAKBJNM0 Housing ref.: 2995 Coil ref.: 481865 Protection class: Assembly wt. (g): 510 Body: Seat disc: Anod.

More information

RedCos-P Pressure sensor 20 Pa Pa

RedCos-P Pressure sensor 20 Pa Pa RedCos-P Pressure sensor 20 Pa... 7.500 Pa Electrical, explosion-proof pressure / differential pressure sensors 24 VAC/DC supply voltage, 0...10 V / (0) analogue output EC type-approved in acc. with ATEX

More information

Solenoid Valves Type 3963

Solenoid Valves Type 3963 Mounting and Operating Instructions Solenoid Valves Type 3963 Fig. 1 General Assembly, commissioning and operation of these devices may only be performed by experienced personnel. Proper shipping and appropriate

More information

User Guide. RAE PowerPak

User Guide. RAE PowerPak User Guide RAE PowerPak Copyright 2009 Honeywell Analytics. Ordering Replacement Parts: If you need replacement parts please contact Honeywell Analytics Representative. Contents 1 Safety Instructions...

More information

M-100X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

M-100X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications Explosion Proof Adjustable Flow Switch with Right Angle Flow Key Features Field adjustable Infinite flow range Extremely accurate and sensitive Low pressure drop UL recognized for hazardous location ATEX

More information

JUMO dtrans p20 DELTA

JUMO dtrans p20 DELTA Data Sheet 403022 Page 1/9 JUMO dtrans p20 DELTA Differential pressure transmitter Brief description The JUMO dtrans p20 DELTA differential pressure transmitter with HART interface combines maximum precision

More information

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System POWER TROLLEY 8 Model: SINE 1548 Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System Version 07 CONTENTS Page 1. INTRODUCTION... 1 2. USING THE POWER TROLLEY.... 2 3. BATTERY BACKUP

More information

APS & APIS ATEX AIRPOWER SWITCH BOXES FEATURES DESCRIPTION

APS & APIS ATEX AIRPOWER SWITCH BOXES FEATURES DESCRIPTION page 1 DESCRIPTION The switch boxes are suitable for rotary actuators and are the industry leader in versatility, quality and approvals gained. Models include APS standard range with a variety of outputs

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview. Level Measurement Pointek CLS300 Standard Siemens AG 20 Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level switch with optional rod/cable

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview. Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

Hydraulic Valves «DSV»

Hydraulic Valves «DSV» Hydraulic Valves «DSV» Edition 09 01 Hydraulic Valves «DSV» Table of contents General information Integrated electronics amplifier and controller «DSV»...1.13-75 Product over-view and/or data sheets Proportional

More information

Ex m Solenoid Operator Type 0519

Ex m Solenoid Operator Type 0519 nass magnet GmbH Eckenerstrasse 4-6 D-30179 Hannover Doc. No. 113-720-0002 Revision No. 2 01.06.2015 Ex m Solenoid Operator Type 0519 Operating Instructions Dear Customer! To ensure the function and for

More information

Products for. Section

Products for. Section 2 Products for Section Chemical Industries Grain silos Oil and Gas industry Plastics Fertilisers and insecticides Wood Cosmetics and perfumes lcohol and spirits Pharmaceutical Industries, etc. 90 2005-2006

More information

200150, & Accelerometers Bently Nevada* Asset Condition Monitoring

200150, & Accelerometers Bently Nevada* Asset Condition Monitoring 200150, 200155 & 200157 Accelerometers Bently Nevada* Asset Condition Monitoring Description The 20015x Accelerometers are general purpose, wide frequency, case-mounted seismic transducers designed for

More information

EPS/ELA-Series User Manual EPS/ELA 250W

EPS/ELA-Series User Manual EPS/ELA 250W EPS/ELA-Series User Manual EPS/ELA 250W EPS Stromversorgung GmbH Tel: +49 (0)821 570451 0 Index 3 Page: 1 Table of contents: Page 1. Features of ELA-Series... 3 1.1 Basic Functions... 3 1.2 Options...

More information

Fisher i2p 100 Electro Pneumatic Transducer

Fisher i2p 100 Electro Pneumatic Transducer Product Bulletin D103197X012 i2p 100 Transducer Fisher i2p 100 Electro Pneumatic Transducer The Fisher i2p 100 electro pneumatic transducer, shown in figure 1, uses a converter module that converts a milliampere

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics /-, 5/- 5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx

More information

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet All Metal Variable Area Flow Meter BGN Technical Data Sheet Extremely robust through star guiding system instead of guiding rod Flow metering of liquids, gases and steam Available up to nominal size of

More information

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1 Data Sheet DS/NGB-EN Rev. B Multi barriers Measurement made easy Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1 Change from two to one column Multi barriers Change from one to two columns

More information

FIREMAN'S MICROPHONE POWER SUPPLY FOR THE VOICE ALARM SYSTEMS 24V

FIREMAN'S MICROPHONE POWER SUPPLY FOR THE VOICE ALARM SYSTEMS 24V DSOS24V v.1.0 FIREMAN'S MICROPHONE POWER SUPPLY FOR THE VOICE ALARM SYSTEMS 24V EN* Edition: 2 from 30.08.2017 Supercedes edition: 1 from 24.05.2016 PSU features. Compliant with the requirements of the

More information

Smart Pressure Transmitter

Smart Pressure Transmitter DOC. NO.: C3100L-E16B Smart Pressure Transmitter with Diaphragm Seal MODEL APT3100L DUON System Co., Ltd. 298-29, GONDAN-RO, GUNPO-SI, GYEONGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200

More information

Passive Speed Sensors

Passive Speed Sensors 5/8 18 FAMILY General Purpose 70085-1010-001 1.125 (28.57) 70085-1010-003 2.625 (66.67) 70085-1010-018 3.625 (92.07) 70085-1010-118 5.000 (127.00) (Select cable from group A, see index) Output Voltage

More information

Certificate of Compliance

Certificate of Compliance FF0001 Certificate of Compliance Certificate: 1345550 Issued to: Eaton Electric Ltd. Great Marlings Butterfield, Luton Bedfordshire LU2 8DL United Kingdom Attention: Mr. Peter Rigling The products listed

More information

AS-I

AS-I Digital Positioner 8049 Compact digital positioner for pneumatic control valves. Positioner can be integrated into valve actuator (no external moving parts for stroke feedback) Wide range of strokes 3-8

More information

Technical Information

Technical Information Technical nformation - Second Generation Solid State Overload Relays Technical nformation -ED1... -EE... -EE...D Rated nsulation Voltage - U [V] 69 C Rated nsulation Strength- U imp [kv] 6 C Rated Operation

More information

Lexium integrated drives

Lexium integrated drives Description ILp for DeviceNet, EtherCAT, Modbus TCP, ILE with brushless DC motor Description ILE comprise control electronics with a fieldbus interface for DeviceNet, EtherCAT, Modbus TCP or and a brushless

More information

Flap-Type Flow Meter Prall

Flap-Type Flow Meter Prall Suitable for H 2 O, acids, alkaline solutions and gases Spring-loaded flap Horizontal or vertical direction of flow Largely independent of viscosity Limit contacts, optional Analog output 4 20 ma, optional

More information

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , E X - C O N T R O L S T A T I O N S Moulded plastic Version for Zone 1 and Zone 21 Even under the most adverse conditions, CEAG control stations can be used and operated reliably. The enclosures consist

More information

Relative and absolute pressure transmitter type 528

Relative and absolute pressure transmitter type 528 Relative and absolute pressure transmitter type 528 Pressure range -1... 0 60 bar The compact type 528 pressure transmitter is based upon the well proven ceramic technology developed by Huba Control over

More information

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip Electrical Temperature Measurement Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip WIKA Data Sheet TE 60.22 Applications Temperature measurement at bearings of: T Pumps T Gears T Motors

More information

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L Temperature Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L WIKA data sheet TE 65.12 for further approvals see page 2 Applications Chemical industry Petrochemical industry

More information