Master Slave Converter [ VAC & VAC]
|
|
- Aileen Thornton
- 6 years ago
- Views:
Transcription
1 Master Slave Converter [ VAC & VAC] Contents: Installation...1 Wire Diagram...4 Exploded View...6 Intended Use: To provide simultaneous operation of up to five Midmark compressors connected to a common operatory air supply line. Note: Low voltage control is required on the designated master compressor only. Language of origin: English Step 1: Install power supply. A) Select which compressor will be the master. Midmark recommends the compressor with the least amount of run hours should be the master. B) Verify voltage on master compressor matches voltage on master slave converter box. Refer to wire diagrams in this manual. C) Shut off main power supply to all compressors. D) Mount master slave converter box if desired. E) Remove compressor electrical box cover. F) Drill 13/16 hole on left side of compressor electrical box. G) Install conduit through 13/16 hole and connect to one of the on/off switches in the compressor electrical box as shown. H) Connect ground wire to ground screw in compressor electrical box. I) Install compressor electrical box cover. Note: If mounting master box is desired, mount box close enough to the compressor electrical boxes for cables and power supply conduit will reach connections. Mounting screws are not included. The compressor you connect the conduit to will be considered the master compressor. 13/16 Drilled Hole Conduit On / Off Switch Ground English Rev. A (7/12)
2 Low Voltage Wires on Back of Compressor Control Box Step 2: Install slave cables to all slave compressors. A) Remove wire nut from low voltage wires on back of compressor electrical box. B) Connect one master slave converter box cable to low voltage wires, Red to Red and Black to Blue. C) Repeat A) and B) for each compressor your connecting to the master slave converter box. D) Install a wire nut on each master slave converter box cable wire not being used. E) Turn main power supply on for each compressor. Note: Master compressor will be the only one that stays connected to remote switch (Master Control Panel) in operatory. Slave Cable from Master Slave Converter Box English-2
3 Step 3: Adjust slave compressor pressure switches. A) Adjust pressure switches in the slave compressors, not the master compressor, to ensure the switch stays closed through cycle. Midmark Brands... B) Remove pressure switch cover. C) Turn adjustment nut clockwise until switch stays closed through cycle. D) Install pressure switch cover. E) Restore power to compressors. Note: The master compressor is the one you connected the master slave converter conduit power supply to in step 1. Midmark PowerAir Pressure Switch Adjustment Nut Shown Note Older style Midmark compressors may only have two wires in pressure switch. English-3
4 Master Slave Converter Box Wire Diagram 115 VAC Contactor Master Slave Converter to Slave Compressors Master Slave Converter Conduit Power Supply To Master Compressor YL BL WH Transformer Ground OR GN English-4
5 Master Slave Converter Box Wire Diagram 230 VAC Contactor Master Slave Converter to Slave Compressors Master Slave Converter Conduit Power Supply To Master Compressor YL BL WH OR Transformer Ground GN English-5
6 Serial Numbers / Dates: all Service Parts Item Description Qty. 1 Screw, Panhead, ( x.500) 4 2 Dim, Rail 1 3 Transformer, 240V / 115V 50/60/HZ 1 4 Nut Keps with tooth lock washer, ( ) 4 5 Contactor 1 English-6
PowerAir Compressor Installation
PowerAir Compressor Installation Applies to Models: P21-115 Volts P22, P32-230 Volts P52, P72-230 Volts Equipment Alert Compressor system must be installed per local plumbing and electrical codes. Model
More informationSpring Bearing Rocker Replacement Installation [Kit # ] for Elevance Continental-Style Delivery Unit
Spring Bearing Rocker Replacement Installation [Kit # 002-2076-00] for Elevance Continental-Style Delivery Unit Note Use this kit to replace one or more Spring Bearing Rockers in an Elevance Continental-Style
More informationFlex Work Station Delivery Units Installation Guide
Flex Work Station Delivery Units Installation Guide Special Tools Level 1/4" Deep Well Socket 3/8" Masonary Bit 9/32" Wood Bit Hammer Drill Remove any packaging from the skid and the floor or wall mount
More informationSide Delivery Unit Installation
Side Delivery Unit Installation CONTENTS Mounting Location... 1 Minimum Cabinet Size Requirements... 1 Mounting Requirements... 1 Regulator Installation... 2 Cabinet Mount Bracket Installation... 2 Wall
More informationClassicSeries Compressor Installation
ClassicSeries Compressor Installation Applies to Models: CL21-115 Volts CL22, CL32, CL52-208- 230 Volts Equipment Alert Compressor system must be installed per local plumbing and electrical codes. Note:
More informationRock Compressors. Service and Parts Manual. Twin R22 Triple R42 FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY. Model Numbers: R42 Shown
Rock Compressors Model Numbers: Twin R22 Triple R42 Service and Parts Manual R42 Shown FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY SF-1862 Part No. 004-0476-00 Rev. C ( /2013) Table Of Contents General
More informationPowerVac. Service and Parts Manual P3 P5 P7. Single Vac Units. Twin Vac Units P6 P10 P14 FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY.
PowerVac Model Numbers: Single Vac Units P3 P5 P7 Earlier Version Current Version Service and Parts Manual Twin Vac Units P6 P10 P1 FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY SF-1873 Part No. 00-09-00
More informationCylinder Rod End Replacement Kit [ ]
Cylinder Rod End Replacement Kit [002-2068-00] Contents: Installation...1 Special Tools: none Language of origin: English Step 1: Inspect components. Step 2: Position chair. A) Move the back section to
More informationPowerMax PM-1 PM-3 PM-4. Service and Parts Manual FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY. Model Numbers:
PowerMax Model Numbers: PM-1 PM-3 PM-4 Service and Parts Manual FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY SF-1920 Part No. 10559400 Rev AA1 (7/14/17) Table Of Contents General Information Section A Section
More informationRated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications
WPC1-XXXX-T Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH
More informationI-BFV.KIT Butterfly Valve Gear Operator Replacement
SERIES 5, 05,, and 0C WARNING Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before
More informationProduct Name Chair Conversion Kit (to Console Delivery Unit) Installation [Kit # xx]
Elevance Product Name Chair Conversion Kit (to Console Delivery Installation Unit) Installation [Kit #002-1965-xx] Attention: Use this kit to convert an Elevance Chair to a Chair with an Elevance Console
More informationPowerMax Surgical Suction Producers
PowerMax Surgical Suction Producers Models: PM-1, PM-3, PM-4 Installation & Operation 10496800 Rev. B Table of Contents Section 1 About PowerMax...1 Section 2 Specifications & Model Selection...3 2.1
More informationKnee Crutches / Cladding [9A410 / 9A411 / 9A412 / 9A413]
Knee Crutches / Cladding [9A40 / 9A4 / 9A42 / 9A43] Intended Use: To support patient s knees / legs during examinations. Requirements: 604 / 622 / 623 models require a special cladding kit to accommodate
More informationProcenter Delivery, Console Mounted on an Elevance Chair Installation Guide
Procenter Delivery, Console Mounted on an Elevance Chair Installation Guide Language of origin: English Equipment Alert Do not remove wraps or packaging from the delivery flex arm assembly until it is
More informationClassicSeries Wet-Ring Vacuums Single Model Numbers: CV3 CV3R CV5 CV5R CV6 CV6R CV10 CV10R. Service and Parts Manual
ClassicSeries Wet-Ring Vacuums Single Model Numbers: CV3 CV3R CV5 CV5R Service and Parts Manual Twin Model Numbers: CV6 CV6R CV10 CV10R FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY SF-1915 Part No. 10546800
More informationProduct Name Chair Conversion Kit (to LR Delivery Unit) Installation [Kit # xx]
Elevance Product Name Chair Conversion Kit (to LR Delivery Unit) Installation Installation [Kit #002-1966-xx] Attention: Use this kit to convert an Elevance Chair to a Chair with an Elevance LR mounted
More informationRated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications
WPC-1 Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH POOL AND
More informationMidmark Cabinet / Wall Light Installation
Midmark Cabinet / Wall Light Installation [Full size template is available: 003-1289-00] warning Equipment is not suitable for use in the presence of a flammable anesthetic mixture. Equipment Alert Before
More informationMaster Series. Gas XPress Grill. Parts List. Models, Non-CE & CE Versions: XG24 XG36
Master Series Gas XPress Grill Parts List Models, Non-CE & CE Versions: XG24 XG36 Document Number: G_GHD_PL_XPRESS_XG24ANDXG36 (rev 3 updated: /6) Cooking Zone Designation The Xpress Grill is a cooking
More informationTechnical Service Bulletin
TSB 89-041 Rev. D Page 1 of 7 POWER CONTACTOR UP-DATE KIT # 99346 APPLICABLE TO: PURPOSE: CAD-17000, CAD-25000 To Replace Manufacture s Discontinued Model GENERAL: In order to simplify installation of
More informationSOLAR-150HD. 150-Watt Dual Halogen Illuminator. Service Manual Bowdendale Avenue Jacksonville, FL 32216
SOLAR-150HD 150-Watt Dual Halogen Illuminator Service Manual 6018 Bowdendale Avenue Jacksonville, FL 32216 Customer Service: 904 731-5869 FAX 904 733 0012 Toll Free 800-684-6404 TABLE OF CONTENTS Page
More informationMaster Series Gas XPress Grill
Master Series Gas XPress Grill models XG24, XG36 (non-ce & CE versions) Phone (US & Canada): 800 427 6668 Fax (US & Canada): 800 36 7745 www.garland-group.com G_GHD_PL_XPRESS_XG24ANDXG36 (Rev ) Quality
More informationInstallation, Operation and Maintenance Manual
Document 458295 Automatic Fire Damper Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,
More informationEmotron DCM Control Unit
Emotron DCM Control Unit Data sheet English 9 2 3 4 5 6 7 8 The Emotron DCM is a control unit that remotely controls submersible pump equipment. Level sensors are not needed to initiate start and stop.
More informationECCII to ECCIII Upgrade Kit
ECCII to ECCIII Upgrade Kit SUPERSEDES: Nothing FORM NO: M51SV-2TO300310 ECCII to ECCIII Upgrade Kit INTRODUCTION Older PoolPaks equipped with the ECCII control system can be upgraded to the ECCIII by
More informationFM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017
FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017 Maxi-Tronic, Inc. 417 Wards Corner Road Loveland, OH 45140 513.398.2500 800.659.8250 FAX: 513.398.2536 info@maxitronic.com
More informationMizer Single Pump and Starter Box
Mizer Single Pump and Starter Box Table of Contents Line Diagram... 2 Overview... 3 Booster Pump Specifications... 3 Water... 3 Electrical... 3 Models... 3 Mounting... 4 Electrical... 6 Motor Rotation...
More informationD-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators
Installation D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators IMPORTANT: The D- Series actuators are intended to control equipment under normal operating conditions. Where failure
More informationAirStar Tandem Installation Kit Part Number 85694
Tandem Installation Kit Part Number 8569 Kit Parts Supplied Part No. Description Quantity 60510 10 PSI Safety Relief Valve 866 85-115 psi 1 85686 Installation Schematic for two Tandem compressors 1 System
More information255 LED Light Dual Conversion Installation [9A584001]
255 LED Light Dual Conversion Installation [9A584001] Note Two single ceiling lights are needed. The ceiling must be capable of supporting the double light system. Weight (max.): 118 lb (53.6 kg); Torque
More informationLoose Components. VetPro 5000 Wall / Cabinet Mount Installation. Applies to Models:
VetPro 5000 Wall / Cabinet Mount Installation warning Equipment not suitable for use in the presence of a flammable anesthetic mixture. Applies to Models: 8001-001 8001-002 8001-005 8001-006 Loose Components
More informationMaster/Slave Actuators Spring Return Rotary 24 Vac - Modulating Control
Document No. 129-312 Master/Slave Actuators Spring Return Rotary 24 Vac - Modulating Control a PL0038R1 c b d e f g i Figure 1. Parts of the Master/Slave Actuators. h a. Actuator b. Shaft adapter c. Position
More informationSeries BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1
Series Bulk Flow Monitor Specifications - Installation and Operating Instructions Bulletin FL-1-4x 3/4 CONDUIT KNOCKOUTS BFS 1A FUSE RED LED RELAY 5-9/64 [130.45] TRANSFORMER 3[76.20] GREEN LED 7 [177.80]
More informationTE2010-GE Instructions manual
TE2010-GE Instructions manual Hardware: 3.1-4.0 Software: 3.7 PREFACE Thanking you for preference, TECNOELETTRA SRL hopes that the use of this equipment could be a reason of satisfaction. This manual is
More informationB to A Solenoid Adapter Kit Installation & Troubleshooting Guide
B to A Solenoid Adapter Kit Installation & Troubleshooting Guide English B to A Solenoid Adapter Kit Thank you for purchasing a Rain Bird B to A Solenoid Adapter Kit. This durable solenoid assembly provides
More informationProcenter Delivery Mounted on a Free Standing Treatment Console (FTC) Installation
Procenter Delivery Mounted on a Free Standing Treatment Console (FTC) Installation Electrical Requirements: 24 VAC, 3.2 Amp 13VAC, 2 Amp Attention These instructions apply to Midmark cabinetry. For other
More informationDodge Engineering & Controls, Inc. Toll Free (877) Fax: (978) ES142 Spring Return Electronic Actuators
a EA0655R1 c b e f g d h a. Actuator b. Shaft adapter c. Position indicator d. Shaft adapter locking clip e. Position indicator adapter f. Mounting bracket (for dampers) g. Mounting screws h. 3 mm hex
More informationS1820 CONVEYOR OVEN REPLACEMENT PARTS MANUAL (with WIRING DIAGRAMS)
SPL081505-PF-BD August 15, 2005 S1820 CONVEYOR OVEN REPLACEMENT PARTS MANUAL (with WIRING DIAGRAMS) EFFECTIVE with SERIAL #351410405 and AFTER Serial # Code First 4 digits - order of production Fifth digit
More information3 Phase Smart Controller
3 Phase Smart Controller Installation and Owner s Manual STP-SCIII 208-230 VAC, 60Hz, 120 Volt Coil Franklin Fueling 3760 Marsh Rd. Madison WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838
More informationThis document describes the commissioning checklist procedures for the Capstone MicroTurbine systems.
Capstone Capstone Turbine Corporation 21211 Nordhoff Street Chatsworth CA 91311 USA Telephone: (818) 734-5300 Facsimile: (818) 734-5320 Website: www.microturbine.com Work Instructions Commissioning Checklist
More informationTT /17c INSTALLATION INSTRUCTIONS. Introduction. Power Tools Required
TT-39 8/7c INSTALLATION INSTRUCTIONS Original Issue Date: 4/02 Model: Model KC, KS, and KEP Automatic Transfer Switches Market: Transfer Switches Subject: User Interface Cover Kits GM22703-KP and GM22703-KP3
More informationTemperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A
Temperature Control Panel Wiring Diagram Model: ISPA-0-P-5A Shift Controls, Inc. Installed Options: TC Jack Panel Connector Interlock Relay, RLY- 5A Power Cord www.shift-controls.com support@shift-controls.com
More informationRated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications
WPC-2 Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH POOL AND
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split System Air Conditioners HB 180/240, HF -15,-20 Models Only
ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split System Air Conditioners HB 180/240, HF -15,-20 Models Only GENERAL These split-system condensing units are designed to
More informationRated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications
WPC2-XXXX-T Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH
More informationRain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit
Rain+Birdt Simple To Set r (SST) Setup & Operation Instructions English Installation...2 Tools and Supplies Needed...2 Step 1. Mount r...2 Step 2. Connect Power...2 Indoor r...2 Outdoor r...2 Step 3. Connect
More informationWater to Water Geothermal Heat Pump 3-Phase Models Both 208 & 480
Installer Water to Water Geothermal Heat Pump 3-Phase s Both 208 & 480 Installation Instructions : THA-***-2 (208, 3-Phase) THT-***-2 (208, 3-Phase) THA-***-3 (480, 3-Phase) THT-***-3 (480, 3-Phase) This
More informationRated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications
WPC-2 Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in its entirety before performing any installation work. FOR USE WITH POOL AND
More informationMODEL L-1C PARTS MANUAL. Rev 1.00A C M A D I S H M A C H I N E S K N O T T A V E N U E GARDEN GROVE, CALIFORNIA
MODEL L-1C PARTS MANUAL Rev 1.00A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-854- 6417 F A X 7 1 4-8 9 5-2141 www.cmadishmachines.com TABLE OF CONTENTS
More informationInstallation Instructions
30RAP010-150, 38APS05-065, 38APD05-130 Ground-Fault Interrupter Convenience Outlet Accessory Installation Instructions Part No. 30RA-900---058, 30RA-900---059 SAFETY CONSIDERATIONS Installation of this
More informationCharcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st
Venting Methods This range hood is factory set for venting through the roof or wall. For non-vented (re-circulating) installations, see Ductless Conversion on Page 7. Vent work can terminate either through
More informationMODEL GL-X PARTS MANUAL
MODEL GL-X PARTS MANUAL Rev. 1.03A CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-8 95-2 141 www.cmadishmachines.com TABLE OF CONTENTS MODEL CMA-GL-X 1. PARTS MANUAL...3
More informationPowerVac G. Service and Parts Manual G3 G5 G7 G6 G10 G14. Model Numbers: Single Vac Units. Twin Vac Units FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY
PowerVac G Model Numbers: Single Vac Units G3 G5 G7 Service and Parts Manual Twin Vac Units G6 G10 G14 FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY 004-0790-00 (10/3/17) 2010 Midmark Corp. 60 Vista Drive
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS
ACCESSORY KIT INSTALLATION INSTRUCTIONS GENERAL Low Ambient Accessory For Air Cooled Split-System Air Conditioners HA 00, HB 60 / 80 / 600, HF-25, HL-0 / -0 / -50 Models These split-system condensing units
More informationINSTALLATION AND OPERATION MANUAL ARM-4073 AUTOMATIC REPRESSURE MODULES
INSTALLATION AND OPERATION MANUAL ARM-4073 AUTOMATIC REPRESSURE MODULES SYSTEM CONCEPT When not transferring fuel, the pressure in the underground closed piping system of a gasoline station may fall due
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS
ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split-System Air Conditioners HA 00, HB 60 / 80 / 600, HF-25, HL-0 / -0 / -50 Models GENERAL These split-system condensing units
More informationInstruction Bulletin. Jockey Pump Controller
Instruction Bulletin Jockey Pump Controller Installation Start Up Service This instruction bulletin is a guide for personnel involved with maintenance, engineering and approval of Fire Pump equipment and
More informationEPB Series Battery Powered Punchdown Tool. User Manual. 134 Marbledale Road Tuckahoe NY Tel: Fax:
EPB Series Battery Powered Punchdown Tool User Manual 134 Marbledale Road Tuckahoe NY 10707 Tel: 914-793-0700 Fax: 914-793-4527 sales@jonard.com Table of Contents Features.2 Product Selection..2 Operating
More informationRemote Temperature Controller for Heated Mold Shoes, using a RTD/Digital Display, # C (version pre-2009).
Knowledge Base Article Type: Instructions Remote Temperature Controller for Heated Mold Shoes, using a RTD/Digital Display, #601127.C (version pre-2009). Description: Instructions on How to properly set-up
More informationASI Model 8374 Automatic Roll Towel Mechanism Owner s Manual
ASI Model 8374 Automatic Roll Towel Mechanism Owner s Manual 1610131300 Rev B 17Jun2017 1 Fig. 1.1 DIM S INCH [MM] Fig. 1 Designed for maximum sanitary use, the 8374 Automatic Roll Towel Mechanism automatically
More informationTRIPLE FOAM INSTALLATION MANUAL Part # FOAMSTRMRTPL00X
TRIPLE FOAM INSTALLATION MANUAL Part # FOAMSTRMRTPL00X TABLE OF CONTENTS Equipment Specifications Page: 1 Suggested Tools and Installation Materials Page: 2 Installation Instructions Page: 2 Initial Start-Up
More informationInstallation Instructions: Read these instructions in its entirety before performing any installation work.
WIR-TRAN Rated for use on 110/120VAC 60Hz applications Installation Instructions: Read these instructions in its entirety before performing any installation work. FOR USE WITH POOL AND SPA PRODUCTS ETL
More informationM9216 Series Electric Spring Return Actuators
*34636461G* 34-636-461, Rev. J Installation Instructions M9216 Issue Date October 217 M9216 Series Electric Spring Return Actuators Installation IMPORTANT: The M9216 Series actuator is intended to control
More informationP445 Series Electronic Lube Oil Control
FANs 125, 121 s Section P Product/Technical Bulletin P445 Issue Date 0100 P445 Series Electronic Lube Oil The P445 Series Electronic Lube Oil is designed for use on refrigeration compressors equipped with
More informationJunction Boxes. Common Components Air / Water Control Valves. Contoured Junction Box. Small Junction Box. Elevance Junction Box
7 8 7 8 8 Junction Boxes Common Components...-89-99 Air / Water Control Valves Contoured Junction Box DAi Small Junction Box Elevance Junction Box TP Rev. A Square Junction Box (optional) Camera Junction
More informationMODEL L-1X & L-1X16 PARTS MANUAL
MODEL L-1X & L-1X16 PARTS MANUAL Rev 1.17A CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-8 95-2 141 TABLE OF CONTENTS MODEL CMA-L-1X & L-1X16 1. PARTS MANUAL...3
More informationMcQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018
Replacement Parts List No. 700011100 Revision B 02/2018 McQuay Enfinity Horizontal Water Source Heat Pump WCRH, WCRW 007, 009, 012 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationInstallation, Operation, and Maintenance Manual. Automatic Fire Damper
Installation, Operation, and Maintenance Manual Automatic Fire Damper Part # 458295 Designed to close in fire situations. Reset by activating the reset switch. UL Listed Constructed in Accordance with
More informationINSTALLATION INSTRUCTIONS. Timer Features
TT-403 4/6c INSTALLATION INSTRUCTIONS Original Issue Date: /04 Model: RDT, HDT, and KSS-J Automatic Transfer Switches Market: ATS Subject: Programmable Exerciser Kits GM47597-KA, -KA, KA3, -KP, -KP, and
More informationTroubleshooting Guide
Troubleshooting Guide This guide contains information for identifying and correcting issues that may arise. Applicable Models: i200 i200p i250 i250p i200x i201x i250x i251x iq251 iq251d iq751 iq1001 iq1501
More informationMODEL CMA-180UC PARTS MANUAL Rev 1.19A
MODEL CMA-180UC PARTS MANUAL Rev 1.19A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 wwwcmadishmachines.com TABLE OF CONTENTS
More informationMcQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016
Replacement Parts List No. 700011400 Revision C 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationMcQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016
Replacement Parts List No. 700011300 Revision B 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 030, 036, 042 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationR81EAA Type Plug-In Electronic Circuit Board Kit For Series M100 Motor Actuators
R81EAA Type Plug-In Electronic Circuit Board Kit For Series M100 Motor Actuators Installation Sheets Manual 121 Relays and Contactors Section R Technical Bulletin R81EAA Application R81 plug-in electronic
More informationH20.5 Series Electric Fryers
Component Box Assembly and Associated Hardware, Thermostats and Related Components and Controller Component Box Assembly and Associated Hardware, Thermostats and Related Components and Contro FRY_P_0002_12_14_Component
More informationApplication Engineering
Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor
More informationBITZER Liquid Injection Guidelines for CSH Compressors
BITZER Liquid Injection Guidelines for CSH Compressors Liquid Injection Additional cooling may be required during reduced capacity operation, high condensing and / or low evaporating temperatures. Direct
More informationMODEL CMA-180UC PARTS MANUAL Rev 1.19
MODEL CMA-180UC PARTS MANUAL Rev 1.19 CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854- 6417 FAX 714-895-2141 wwwcmadishmachines.com TABLE OF CONTENTS MODEL CMA-180UC 1. PARTS
More informationSystem 350 P352AB Electronic Pressure Control Series
System 350 P352AB Electronic Pressure Control Series System 350 Product Guide 930 Basic Controls Section Product/Technical Bulletin P352AB Issue Date 0200 The P352AB controls are On/Off electronic pressure
More informationInstallation Instructions
Please read all instructions before installing CD-250 Multi-way Dimming Wall Switch Vacancy Sensor Lens Air Gap Isolation Switch Lighted Switch ON/OFF/DIM button SPECIFICATIONS Voltage...120VAC, 60Hz Load
More informationPower Procedures Table
Go To Table Of Contents Next Power Procedures Table Model Numbers: 64-00 thru -005 Service and Parts Manual FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY SF-89 Part No. 004-05-00 Rev (9/0/7) Table Of Contents
More informationPOWER COLOR FAST STOP OFF SLOW. AfterDark IMPORTANT INFORMATION
O W N E R S M A N U A L ON OFF POWER COLOR FAST STOP SLOW AfterDark IMPORTANT INFORMATION Important Information Follow these simple guidelines, to protect against injury and prolong the life of your Polaris
More informationMinimum 27 in-lb torque
LU Series Actuator Minimum 27 in-lb torque For damper areas up to 6.8 sq-ft* All Actuators have BDCM LU Series - At A Glance LUB(X)24-3 (p. 258) LUB(X)24-SR (p. 260) LUX24-MFT (p. 262) Basic Product Flexible
More informationPTAC CONTROL BOARD KIT RSKP0006 INSTALLATION INSTRUCTIONS
PTAC CONTROL BOARD KIT RSKP0006 INSTALLATION INSTRUCTIONS Description Control board installation procedures are described in detail in these instructions. Read and follow these instructions carefully before
More informationMODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER
MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER INSTALLATION INSTRUCTIONS WARNING: The Model 8682 Adaptive Offset Controller must be wired to 24 VAC only. Wiring the unit to 110 VAC will cause serious unit
More informationKEY PARTS PS540-SERIES GAS OVEN KEY PARTS ITEM PART NO. ENGLISH DESCRIPTION QUANTITY
KEY PARTS PS540-SERIES GAS OVEN KEY PARTS ITEM PART NO. ENGLISH DESCRIPTION QUANTITY 1 58504 Temperature Controller 1 2 44687 Blower/Fan Motor 1 3 47797 Conveyor Drive Motor, Standard Speed 1 or 2 3A 47799
More informationB100S - Super Swing. Instruction Manual. Document number: B100S-C Release: V4.0 Date: May 08,2009
B00S - Super Swing Instruction Manual Document number: B00S-C Release: V4.0 Date: May 08,009 ! WARNING This control must be adjusted/serviced by a qualified person. The service technician must be familiar
More informationOperating Instructions
DuroSite & SafeSite Area Light with Adapters Important Information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury,
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS
ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split-System Air Conditioners HA 300, HB 360 / 480 / 600, HF-25, HL-30 / -40 / -50 Models GENERAL These split-system condensing
More information03561 SPEED BOOSTER INSTRUCTION MANUAL. for the Ultra Tugger
INSTRUCTION MANUAL NRTL/C LR 91904-8 03561 SPEED BOOSTER for the Ultra Tugger Read and understand all of the instructions and safety information in this manual before operating or servicing this tool.
More informationHLS Watt Halogen Illuminator Service Manual
HLS-150 150-Watt Halogen Illuminator Service Manual 6018 Bowdendale Avenue Jacksonville, FL 32216 Customer Service: 904 737 7611 FAX 904 733 4832 Toll Free 877 677 2832 (English) TABLE OF CONTENTS Page
More informationTech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) MODEL C ELECTRIC HYDRAULIC PUMP
SPX Corporation 5885 11th Street Rockford, IL 61109-3699 USA Internet Address: http://www.powerteam.com Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031
More informationParts Information. Commercial Microwave Oven
Parts Information Commercial Microwave Oven Important notes: This is an uncontrolled document. There is no record of its distribution and no corrections will be provided. Models and Manufacturing numbers
More informationResidential microinverter system
PV array Rooftop junction box to transition from TC-ER cable to THWN-2 Conduit run over 10 ft. long GARAGE Existing exterior service panel Residential microinverter system If an inverter is dedicated to
More informationSERVICE MANUAL (INTERNATIONAL)
SERVICE MANUAL (INTERNATIONAL) IMPINGER CONVEYOR OVENS MODEL 1421-000-E, 1454, 1455 WITH PUSH BUTTON CONTROLS Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United States
More information30-SS1203A 12,000 LB CAPACITY SCISSOR ALIGNMENT LIFT INSTALLATION AND SERVICE MANUAL P/N:
WITH STRENGTH 30-SS1203A 12,000 LB CAPACITY SCISSOR ALIGNMENT LIFT INSTALLATION AND SERVICE MANUAL P/N: 420-02553 CONTENTS Product Features and Specifications...1 Installation Requirement...3 Steps of
More informationHydrovar and Packaged Hydrovar
Hydrovar and Packaged Hydrovar MOTOR MOUNT VARIABLE SPEED PUMP CONTROLLER AND INTEGRATED PUMP PACKAGES BRHYDROVAR R3 Goulds Water Technology Hydrovar and Packaged Hydrovar Hydrovar Variable Speed Drives
More informationMinimum 27 in-lb Torque
LU Series Actuator Minimum 27 in-lb Torque For damper areas up to 6.8 sq-ft* Actuators in bold have BDCM LU Series - At A Glance LUB(X)24-3 (p. 351) LUX120-3 (p. 353) LUB(X)24-SR (p. 355) LUX120-SR (p.
More informationOutdoorXUPS-600AHV-8364
OutdoorXUPS-600AHV-8364 TSi Power s OutdoorXUPS-600AHV-8364 provides secure and uninterrupted 230 vac power to critical loads. 1) Weather-tight metal cabinet (IP44 or NEMA 3R rated) 2) 2A and 2B are wide
More information