INSTALLATION INSTRUCTIONS 410/420 SERIES PUSH SWITCH
|
|
- Rodney Bradford
- 6 years ago
- Views:
Transcription
1 801 Avenida Acaso, Camarillo, Ca (805) /420 SERIES PUSH SWITCH (N/C) Contact Type: SPDT (Form C) (COM) (N/O) LAMP 28VDC MAX P:\INSTALLATION INST\Push and Key Switch\INST vsd REV A 0311 Page 1
2 3580 Willow Lane, Westlake Village, CA (805) Fax: (805) MODEL 422 PUSH SWITCH 422GPE 422NGPE (N/C) Contact Type: SPDT (Form C) (COM) (N/O) LAMP 28VDC MAX P:\INSTALLATION INST\Push and Key Switch\INST 422.vsd 0305 Page 1
3 * 0 # PUSH TO EXIT * 0 # PUSH TO EXIT SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, CA (805) service@sdcsecurity.com MODEL 413NU & 423U PUSH SWITCH 160 SECOND ADJUSTABLE TIME DELAY When the button is pressed, the lock releases for 160 seconds. If pressed again during the lock release period, the unit will Retrigger starting a new release period. Input Voltage : Indicator : 10/20ma Output Relay: DPDT Max Load : 5 AMP 12/24VDC 423U TYPICAL WIRING 413NU 12/24VDC 160 SEC ADJ POT BLK /BLK /BLK COM B /BLK A VIO BLU COM 413NU OR 423U MANUAL RELEASE DEVICE BLK /BLK /BLK COM B /BLK A VIO BLU COM 413NU OR 423U MANUAL RELEASE DEVICE C MD31D FAIL SAFE REQUESTTOEXIT SENSOR DEVICE C MD31D FAIL SAFE REQUESTTOEXIT SENSOR DEVICE C V V C V V ACCESS CONTROL ACCESS CONTROL MD31D MD31D EMLOCK C C FAILSAFE LOCK FAIL SECURE LOCK ACCESS 413NU CONTROL OR 423U ELECTRIC STRIKE ACCESS 413NU CONTROL OR 423U P:\INSTALLATION INST\Push and Key Switch\INST413NU423U.vsd REV E 1013 Page 1
4 # * PUSH TO EXIT SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805) service@sdcsecurity.com MODEL 413MN & 423M PUSH SWITCH FIXED 30 SECOND TIME DELAY This push to exit button is specifically intended for installation on Access Controlled Egress doors as described in the Boca code. A motion detector is the primary means of releasing a magnetic lock on the door. The push to exit button is intended, as a back up means of releasing the lock in the event there is a problem with the motion detector. When the button is pressed, the lock releases for 30seconds. If pressed again during the 30seconds lock release period, the unit will Retrigger starting a new 30second lock release period. TYPICAL WIRING 12/24VDC BLK /BLK /BLK COM B /BLK VIO BLU COM C A 413MN OR 423M MANUAL RELEASE DEVICE MD31D FAIL SAFE REQUESTTOEXIT SENSOR DEVICE 423M 413MN Input Voltage : Indicator : 10/20ma Output Relay: DPDT Max Load : 5 AMP C V V ACCESS CONTROL MOTION DETECTOR EMLOCK C FAILSAFE LOCK ACCESS CONTROL MODEL 413MN/423M PUSH TO EXIT SWITCH P:\INSTALLATION INST\Push and Key Switch\INST413M423M.vsd REV D 0213 Page 1
5 801 Avenida Acaso, Camarillo, Ca (805) & 424 PUSH SWITCH 424U 414NU Contact Type: DPDT (Form C) (COM) (COM) (N/O) (N/O) (N/C) (N/C) LAMP 28VDC MAX P:\INSTALLATION INST\Push and Key Switch\INST vsd REV A 0608 Page 1
6 SECURITY DOOR CONTROLS 3580 Willow Lane, Westlake Village, CA (805) Fax: (805) MODEL 415N & 425 ON/OFF PUSH SWITCH N Contact Type: DPDT (Form C) (N/C) (COM) BLK GRN GRN (N/O) (N/C) (COM) (N/O) P:\INSTALLATION INST\Push and Key Switch\INST 415N425.vsd 0908 Page 1
7 3580 Willow Lane, Westlake Village, CA (805) Fax: (805) MODEL 460 REQUEST TO EXIT SWITCH Adjustable Timer 1 40 Seconds * With the jumpers as shown the red s are on in standby and the green s turn on when the relay is on VDC * 1 COM1 COM2 2 Specifications Input Voltage: 12/24VDC Current: On: Idle60mA, Active 120mA Off: Idle10mA, Active60mA Outputs: 1 N.O., 1 N.C., 2 30VDC Switch Operating Environment 40 F to 160 F (40 C to 70 C) Dimensions 4.5" H x 2.75" W x 1.25" D (11.4 x 7 x 3.2 cm) Selectable Bicolor Illumination Status Relay Off Red, Green or None Relay On Red, Green or None Red On Standby Green On Relay Action Red On Relay Active Green On Standby Red Off Green Off P:\INSTALLATION INST\Push and Key Switch\INST460.vsd 0305 Page 1
INSTALLATION INSTRUCTIONS E300 SERIES MAGNETIC CABINET/DISPLAY CASE LOCK
801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS E300 SERIES MAGNETIC CABINET/DISPLAY CASE LOCK The E300 Series magnetic
More informationSECURITY DOOR CONTROLS
CR4 FOUR STATION CONTROL MODULE The CR4 module operates on 12V or 24V DC and provides control of four (4) stations. Each CR4 station accepts a Dry () trigger input and provides one (1) Fused 2 Amp SPDT
More informationSecurity Door Controls
Security Door Controls 801 Avenida Acaso, Camarillo, ca. 930 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com 1575-1576 EMLOCK R INSTALLATION INSTRUCTIONS During installation,
More informationINSTALLATION INSTRUCTIONS 1576DE DELAYED EGRESS EMLOCK
801 Avenida Acaso, Camarillo, Ca. 930 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 1576DE DELAYED EGRESS EMLOCK PUSH UNTIL ALARM SOUNDS. DOOR CAN BE OPENED
More informationSECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)
SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com HI-SHEAR EMLOCKS 1565 & 1566 INSTALLATION INSTRUCTIONS
More informationEZ-B-10 MAGNETIC BOND SENSOR EZ-T-10 TIMER INPUT MODULE. Modular Kit. Modular Kit. EZ-D-10: DOOR POSITION SENSOR Modular Kit
EZ Option Upgrade Kits - Emlock 1511, 1513, 1571, 1573 EMLock EZ Kits Field Upgradeable Option Modules for 1511, 1513, 1571, 1573 SDC s patented EMLock design represents the pinnacle of magnetic lock evolution.
More informationINSTALLATION INSTRUCTIONS MICRO SHEAR EMLOCKS 1561 & 1562 MAX. HOLDING FORCE 2000 LBS.
SECURITY DOOR CONTROLS 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS MICRO SHEAR EMLOCKS
More informationINSTALLATION INSTRUCTIONS SHEAR LOCKING MAGNET 1561TJ MAX. HOLDING FORCE 2000 lbs.
801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS SHEAR LOCKING MAGNET 1561TJ MAX. HOLDING FORCE 2000 lbs. REFER TO THE
More informationINSTALLATION INSTRUCTIONS MINI EXIT CHECK DELAYED EGRESS EMLOCK 1581S
SECURITY DOOR CONTROLS 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS MINI EXIT CHECK
More informationS6100 SERIES REVERSIBLE PANIC/FIRE EXIT RIM DEVICES INSTALLATION INSTRUCTIONS
801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com S6100 SERIES REVERSIBLE PANIC/FIRE EXIT RIM DEVICES INSTALLATION INSTRUCTIONS These instructions
More informationcel SECURITY DOOR CONTROLS Value Engineered Access Hardware sdcsecurity.com Power Supplies Exit Switches
Security Door Controls cel TM Value Engineered Access Hardware Excel E1200 Excel E600 Excel E300 Excel Series Value Engineered Access Hardware from SDC Economically Priced Alternative to Low Cost Imports
More information630 Series Power Supplies
TM 630 Series Power Supplies 631RF Series 1.5 Amp Modular Access Control Power Supply The SDC 631RF Power Supplies have been developed specifically to support electric locks and access controls. The high
More informationEMLock 1500 Series. MEA Listed. New Modular Kits. Online System Wizard and Project Manager at
S E I A L A EMLock 1500 Series SDC s patented EMLock design represents the pinnacle of magnetic lock evolution. The modular EMLock assembly makes them easy to stock, install, upgrade and maintain. Modular
More informationExcel Series Value Engineered Access Hardware
Excel Series Value Engineered Access Hardware Excel E1200 Economically Priced Alternative to Low Cost Imports Quality and Flexibility for Commercial Applications. The Excel product line is designed for
More informationElectrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys...
TABLE OF CONTENTS A Adjustable Angle Bracket (2941/2942)... 6 Angle Brackets (2950 Series)... 9 Armature Mounting Plates (2950 Series)...7-8 C Coordinator Mounting Bracket (2950 Series)... 8 Concealed
More informationElectrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys...
TABLE OF CONTENTS A Adjustable Angle Bracket (2941/2942)... 6 Angle Brackets (2950 Series)... 9 Armature Mounting Plates (2950 Series)...7-8 C Coordinator Mounting Bracket (2950 Series)... 8 Concealed
More informationSpectra Class. N6000 Series Exit Devices SECURITY DOOR CONTROLS. N6100 Rim Mount Exit Device. N6200 Surface Vertical Rod Exit Device.
N6000 Series Exit Devices Spectra Class Rim Mount Surface Vertical Rod N6100 Rim Mount Exit Device For use on single doors or pair of doors with mullion 1-3/4"(44 mm) door thickness standard. Specify thickness
More informationAccessories 286 SDC SECURITY DOOR CONTROLS
8 Security Door Controls From wireless remote controls to durable door holding & release devices, to REX sensors, timers, ball and magnetic switches, and from concealed contact to universal mounting enclosure
More informationACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS
II 1400-10 ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS Features: Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit Protection Standby Battery
More informationGRADE 1 ELECTRIFIED CYLINDRICAL & UNIT LOCKS
GRADE ELECTRIFIED CYLINDRICAL & UNIT LOCKS LAK Function: Specifications: Features: Locked on the outside only. The 00mA @ VDC Vandal resistant clutch lever release inside lever is always unlocked for 9/6
More information5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE
5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE MODEL# 505 ( AMP @ VDC OR 4VDC) MODEL# 5500 ( AMP @ VDC OR AMPS @ 4VDC) MODEL# 5600- (0 AMPS @ VDC) MODEL# 5600-4 (5 AMPS @ 4VDC) IMPORTANT SAFETY INSTRUCTIONS
More informationINSTALLATION INSTRUCTIONS DEGR7700 DELAYED EGRESS ALL IN ONE DEVICE
INSTALLATI INSTRUCTIS DEGR7700 DELAYED EGRESS ALL IN E DEVICE Stop Employee Theft Stop Retail Shoplifting Restrict Airport Patrons Restrict Wandering Patients SOUNDS. DOOR CAN BE The sign provides comprehensive
More informationS6000 Spectra Exit Devices
S6000 Spectra Exit Devices SPECTRA CLASS - SPECIFICATION GRADE EXIT DEVICES FOR SUPERIOR ARCHITECTURAL STYLE & PERFORMANCE The new mechanical SDC S6000 Spectra Series panic and fire rated exit devices
More informationACCESS & EGRESS POWER SUPPLY & DOOR CONTROLS SOLUTIONS. The lock behind the system. SDCSecurity.com
ACCESS & EGRESS SOLUTIONS POWER SUPPLY & DOOR CONTROLS 6 2 7 3 4 1 2 The lock behind the system SDCSecurity.com 800.413.8783 service@sdcsecurity.com Complete Component Considerations 7 3 6 AC Mains 1 Locking
More informationFlight Systems. Replacement for KASSEC DESCRIPTION
DESCRIPTION The is a universal generator controller that will start, stop, and provide engine protection for most generators. Universal replacement for both the 90353 and 90354 KASSEC Compatible with most
More informationProgrammable Output Module Installation Manual
Programmable Output Module Installation Manual PROGRAMMING CODE: (4 digits) (default = 1818) To enter programming mode, press [ ENTER] + programming code ADDRESS 000: 1 / 8 ADDRESS 001: 1 / 8 HOW TO:
More informationADA Compliant Solution REV
Low Energy Swing Door Operator PUSH TO OPEN PUSH TO OPEN PUSH TO OPEN PUSH TO OPEN PUSH TO OPEN ADA Compliant Solution REV 4 ACCESS & EGRESS SOLUTIONS Security Door - THE Controls LOCK BEHIND THE SYSTEM
More informationADA Compliant Solutions
ADA Compliant Solutions BOLLARDS AND PUSH PLATE SWITCHES - WIRELESS AND HARDWIRED For Handicap Access, Automatic Door Activation & Request-to-Exit Applications Door Opener Activation Access Control Request-to-Exit
More informationSpectra Class - Specification Grade Exit Devices for superior Architectural Style & Performance
S6000 & N6000 Spectra Exit Devices Spectra Class - Specification Grade Exit Devices for superior Architectural Style & Performance The new mechanical SDC S6000 & N6000 Spectra series panic and fire rated
More informationARCHITECTURAL DOOR HARDWARE POWER SUPPLIES & TRANSFORMER CATALOG
ARCHITECTURAL DOOR HARDWARE POWER SUPPLIES & TRANSFORMER CATALOG January 1, 2017 v3 West Coast Office (800) 544-4422 East Coast Office (800) 225-6737 intldoorclosers.com Index POWER SUPPLIES & TRANSFORMERS
More informationPower Supplies DORMA PS
Power Supplies DORMA PS DORMA PS Power Supplies Main System On/Off or Fire Panel Relay - The power supply output voltage can be controlled by the main system on/off control relay which accepts a closed
More informationELECTROMAGNETIC LOCKS
Ahlra offers a complete range of access control devices and accessories, including electromagnetic locks, electric drop bolt, Wireless Electric Drop bolt, electric strikes, shear locks, electromechanical
More informationSOLUTIONS ACCESS & EGRESS. The lock behind the system EGRESS CONTROL. 3.1 Egress Bars Key & Exit Switches
ACCESS & EGRESS SOLUTIONS EGRESS CONTROL 3.1 Egress Bars Key & Exit Switches 5 6 2 7 3 4 1 2 The lock behind the system SDCSecurity.com 800.413.8783 service@sdcsecurity.com Complete Component Considerations
More informationMODEL RMS INSTALLATION INSTRUCTIONS. CONTENTS Page A. Introduction 1. Usage 2 2. How it operates 2
CONVEYOR COMPONENTS COMPANY Division of Material Control, Inc. 130 Seltzer Road, PO Box 167 Croswell, MI 48422 USA PHONE: (810) 679-4211 TOLL FREE (800) 233-3233 FAX: (810) 679-4510 Email: info@conveyorcomponents.com
More informationWIRING DIAGRAMS FB4C FE4A/FE5A FH4C FV4C FX4D FY5B PF4MA PF4MB LABEL
FAN COILS ACCESSORY ELECTRIC HEATERS WIRING DIAGRAMS FIG. FIELD-INSTALLED HEATER MODEL FB4C FE4A/FE5A FH4C FV4C FX4D FY5B PF4MA PF4MB LABEL 1 KFCEH0401N03A 18,24 x 001 x 19,25 18,24 18,19,24,25 x 340816-101
More informationARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI
II 1400-6 ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI ACSI 1426-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1092, REV. C INSTALLATION For C-UL Listed applications,
More informationAura CM-54i Surface Mount Illuminated Enclosure Installation Instructions
Aura CM-54i Surface Mount Illuminated Enclosure Installation Instructions 2 Section General Description Camden Aura, Model CM-54i provide the Industry s st Changing State illuminated switch enclosures.
More informationPS24/AC Volt AC 16 Amp
ALTERNATING CURRENT POWER SUPPLY PS24/AC-6 24 Volt AC 6 Amp FEATURES: Mains Fail Relay Output and Indicator. Fuse blow indication and relay output. 6 fused outlets DESCRIPTION: SPECIFICATIONS: Inputs Voltage-
More informationInstallation Instructions
BZ-200, BZ-250, BZ-250-347 Power Pack Auto/Manual Mode Switch BZ-250, BZ-250-347 only SPECIFICATIONS Voltages BZ-200, BZ-250... 120 277 VAC, 50/60 Hz, single phase BZ-250-347... 120 347 VAC, 50/60 Hz,
More informationCB-9 CONTROL BOARD INSTRUCTION MANUAL
CB-9 CONTROL BOARD INSTRUCTION MANUAL AUGUST 95 The CB-9 control board is designed to automate 1 or 2 A.T.A swing gate or sliding gate drive units. This instruction manual gives detailed instructions on
More informationAura CM-55i Flush Mount Illuminated Enclosure Installation Instructions
Aura CM-55i Flush Mount Illuminated Enclosure Installation Instructions Section General Description Camden Aura, Model CM-55i provide the Industry s st Changing State illuminated switch enclosures. They
More informationGCU-10. Automatic Engine Control Unit Operators Manual
GCU-10 Automatic Engine Control Unit Operators Manual KUTAI ELECTRONICS INDUSTRY CO., LTD. TEL : +886-7-8121771 FAX : +886-7-8121775 Website : www.kutai.com.tw Headquarters : No.3, Lane 201, Chien Fu St.,
More informationELECTRICAL SYSTEM RP-7
ELECTRICAL SYSTEM RP-7 This section of the manual does not include integral electrical components of the engine. Refer to section Engine RP-1 for details. This section of the manual is divided into three
More informationHANDLING MECHANICAL INSTALLATION
2 INSTALLATION DESCRIPTION The and 2 Delay Egress Systems are 1500 pound holding force (holding force not evaluated by UL) per leaf electromagnetic locks, electronically controlled to provide a 15 or 30
More informationEMLock 1500 Series. MEA Listed
EMLock 1500 Series SDC s patented EMLock design represents the pinnacle of magnetic lock evolution. The modular EMLock assembly makes them easy to stock, install, upgrade and maintain. Patented SDC 1500
More informationSecurity alarms, warning systems.
SIREN DRIVER BOARD. Free running siren activated by the application of a V DC power source. This module is capable of driving a maximum of 2 x 8 ohm 10W speakers and produces approximately 110 db at one
More informationLOCKNETICS Power Supplies. 510 Series Power Supply Controller 12 and 24 VDC. 505 Series Power Supply. 505DE Series Delayed Egress Controller
505 Series Low voltage DC, regulated, filtered. Step down transformer, fused primary and 6 heavy duty 505 shown with SBP2 KLC screw terminals. 12 VDC - 1 Amp, 24 VDC - 1 Amp, field selectable. Battery
More informationPower Supply. & Door Controllers 238 SECURITY DOOR CONTROLS
Security Door Controls & Door Controllers 5 SDC Access Control Power Supplies have been developed specifically to support access controls and electric locking hardware with clean, consistent power. Combined
More informationSAFETY
24 SAFETY SECURITY ELECTROMAGNETS IDEAL FOR EMERGENCY EXITS AND CONDOMINIUM ENTRY DOORS SILENT AND RESISTANT HOLDING FORCE FROM 150 TO 1500 KG CAN BE APPLIED ON PRE-EXISTING DOORS 25 26 SAFETY www.opera-italy.com
More informationELECTROMAGNETIC LOCKS
safety 17 18 SAFETY ELECTROMAGNETIC LOCKS 12500 Electromagnetic lock Micro series Version: for mortice fixing body in stainless steel protected against humidity Dimensions of the body (mm): 170 x 32 x
More information7281-EA/ET INSTRUCTIONS
7281-EA/ET INSTRUCTIONS The 7281 series uses the 4505 processor controlled timer module a highly accurate 30 second fixed timer or by removing a jumper, may be adjusted to provide endlessly variable time
More informationDoc. No: part_numbering_400.doc Phone (860) Dolphin Road Rev: A Date: 01/26/2007. Fax (860) Bristol, CT, 06010
P-Q Controls, Inc. Doc. No: part_numbering_400.doc Phone (860) 583-6994 95 Dolphin Road Rev: A Date: 01/26/2007 Author: Fax (860) 583-6011 Bristol, CT, 06010 Page: MSOffice 1 of 1 Level Sensor Part Numbering
More informationElectro-Mechanical Swing Operator. Table of Contents
*640072* 640072 Electro-Mechanical Swing Operator Models 8230 & 8240 Installation Instructions Table of Contents General...1 Replacement Parts & System Components...1 1 Pre-Installation Site & Product
More informationSmartLock Accessories
CANSEC ACCESSORIES SmartLock Accessories CA SLbox CA SLBOX SmartLock enclosure 9.5 x 13 x 3 metal enclosure with room for 1 or 2 SmartLock controllers, Cansec power supply and 12V 7 AH battery C Ca ps123a
More informationA1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction
A186-05, Page 1 952-361-3026, INC. (Fax) 952-368-4129 327 LAKE HAZELTINE DRIVE, CHASKA, MN 55318 800-328-0738 A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED Introduction The MAXIGARD A1500
More informationInstallation and Wiring Instructions for the TL- Prefix SARGuide Illuminated Touchpad for 80 Series Exit Devices to ElectroLynx Connector System
Installation and Wiring Instructions for the TL- Prefix SARGuide Illuminated Touchpad for 80 Series Exit Devices to ElectroLynx Connector System U.S. Patent No. 7,04,050 For assistance, contact SARGENT
More informationPackage Contents. Mounting Hardware
Securitron Magnalock Corp. www.securitron.com Tel 800.624.5625 techsupport@securitron.com M680BDCX MAGNALOCK SERIES Installation Instructions Table of Contents Specifications 2 Configuring Options 3 Installation
More informationASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY
00 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) Track Assembly (0-) / Replacement
More informationB100S - Super Swing. Instruction Manual. Document number: B100S-C Release: V4.0 Date: May 08,2009
B00S - Super Swing Instruction Manual Document number: B00S-C Release: V4.0 Date: May 08,009 ! WARNING This control must be adjusted/serviced by a qualified person. The service technician must be familiar
More informationASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY
0 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) / Replacement Motor Key (00KEY) Rod
More informationElectric Dropbolts. Secure and Intelligent Bolts. Fail-Safe Series Functions. DPS & BSS Outputs. Fail-Secure Series Functions
Secure and Intelligent Bolts are mortise mounted and available in fail-safe and fail-secure mode. The Electric Dropbolt Fail-safe series electric dropbolts can be mounted horizontally or vertically and
More informationAccess & Egress Solutions for Building Security and Life Safety
Innovative Access & Egress Solutions for Building Security and Life Safety Security Dealers, Integrators, Installers and Distributors 200+ SDC products are available for shipment by the next business day.
More informationIMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE
USER MANUAL IMI vibration switch INSTALLATION - OPERATION - MAINTENANCE Z0929039_A ISSUED 03/2017 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. contents Overview General
More informationELECTRIC BOLT LOCKS AR-1203A SERIES. (Fail-Safe)(Power to Lock) INSTALLATION INSTRUCTIONS. RoHS. AR-1203A Ver Patent No.
ELETRI OLT LOKS R-1203 SERIES (Fail-Safe)(Power to Lock) INSTLLTI INSTRUTIS RoHS R-1203 Ver.02-0913 Patent No. M 329084 ontents I. Order Information... 1 II. Features & Functions... 1 III. dditional Functions...
More informationALARM CONTROLS CORPORATION MSRP PRICING 2014
ALARM CONTROLS CORPORATION MSRP PRICING 2014 MAGNETIC LOCK WITH U.S. 28 CLEAR ANODIZED FINISH 300S 300 POUND SINGLE DOOR MAGNETIC LOCK, 12 OR 24 VDC 600S 600 POUND SINGLE DOOR MAGNETIC LOCK, 12 OR 24 VDC,
More informationCAPACITANCE LEVEL SWITCH
CAPACITANCE LEVEL SWITCH http: //www.fine-tek.com e-mail: info@fine-tek.com Tel: 886--696789 Fax: 886--68668 4 PRINCIPLE The capacitance level switch measuring principle is based on the "capacitance effects".
More informationPower Transfer Devices
Security Door Controls 4 Power Transfer Devices From frame to door, SDC s power transfer devices provide secure, concealed or vandal-resistant means to transfer power and monitoring signals to doors equipped
More informationEternity-TK-Controller (EDC700 Series)
Eternity-TK-Controller (EDC700 Series) Product Datasheet www.ibuttonlock.com SPECIFICATIONS Power Supply: 12V, 3A Main Relay: 12V, 5A Operating Temp: -18 C to +70 C (0 F to +158 F) Power Consumption: 15
More informationMODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS
MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & STATUS SENSOR SPECIFICATIONS U.L. LISTED, LISTING NUMBER R16759 600 POUND MINIMUM HOLDING FORCE MAGNET SIZE 9-7/8 L x 1-11/16 H x1 W SIZE
More informationElectromagnetic Locks DORMA EML
Electromagnetic Locks DORMA EML DORMA EML-1000M Electromagnetic Lock The DORMA EML-1000M Series Grade 1 electromagnetic locks secure the most demanding openings with 1650 lb of holding force. This lock
More informationGENSET CONTROL MODULE A121A / A241A
Technical Data Sheet GENSET CONTROL MODULE A121A / A241A Features: Models for both 12V and 24V systems. One model for both spark ignition and diesel engines. 4-alarm light outputs with lamp-test provisions.
More informationCX-EMF-2 MULTI-FUNCTION RELAY
ELECTRIFIED S, RELAYS & TIMERS RELAYS & TIMERS ABM MULTI-FUNCTION RELAY FEATURES MICROPROCESSOR CONTROL USER SELECTABLE MULTI-APPLICATION DESIGN PLUG-IN CONNECRS FOR WIRING ACCEPTS UP 7 DRY INPUTS DESCRIPTION
More informationMulti-function. Mono-function 1 NO (SPST-NO)
Features Range of electronic staircase timers 17.5 mm wide Time setting from 30 s to 20 min Zero crossing load switching Switch-off early warning - model 14.01 Suitable for 3 or 4 wire systems, with automatic
More informationEMLock Magnetic Locks
EMLock EMLock Lifetime Warranty NSI/HM 156.23 Grade 1 CSFM 3774-0324:100 ME City of New York 768-80-S GWXT uxiliary Locks CVXJ urglary Resistant Electrically Operated Door Lock UL10C Positive Pressure
More informationVertical Housing EMLock Discount Code GK LIST. Retrofit Kit for Discontinued Locknetics 390+ PLUS
EMLock Vertical Housing EMLock LIST Vertical Housings - Side jamb mount, aprovides 2,400 or 3,300 lbs. of holding force. 1572VV82 Vertical Housing for 1572 EMLock, 8 length, for 84" opening - INCLUDES
More informationMAXIGARD A2000 SPEED SWITCH. Introduction
A107-05, Page 1 952-361-3026, INC. (Fax) 952-368-4129 327 LAKE HAZELTINE DRIVE, CHASKA, MN 55318 800-328-0738 MAXIGARD A2000 SPEED SWITCH Introduction The Maxigard A2000 Speed Switch is designed to monitor
More informationMODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS
MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & STATUS SENSOR SPECIFICATIONS U.L. LISTED, LISTING NUMBER R16759 600 POUND MINIMUM HOLDING FORCE MAGNET SIZE 9-7/8 L x 1-11/16 H x1 W SIZE
More informationBZ-150. Installation Instructions. Power Pack SPECIFICATIONS
SPECIFICATIS Voltages...120/. 50/60Hz Load Requirements Ballast... 20amp @120/ Incandescent... 20amp @ Motor... 1HP @120/240VAC Output...225mA @ (with relay connected) Input Control... 12- Hold... 12-
More informationGate & Door Controller with LCD and Intelligent Technology
2nd Edition Gate & Door Controller with LCD and Intelligent Technology 24Sv1 and 12Sv1 Motor Controllers Setup and Technical information for single motor controller for gates & doors Includes latest Intelligent
More informationCONTROLLER DIAGNOSTIC GUIDE
Proprietary tice: This document contains proprietary information which not to be reproduced, transferred, to other documents, disclosed to others, used for manufacturing or any other purpose without the
More informationProduct Catalogue Date:
Product Catalogue Date:- 01.04.2017 Sr. 1 2 Spring 3 Double 4 Re-style 5 Re-style Spring 6 Re-style Double 7 Center OFF SPDT 8 Center OFF 2-Way Spring 9 Re-Style Center OFF SPDT 10 Re-Style Center OFF
More informationTypical applications are the control of barriers/booms in the parking and access control environments.
Barrier Logic Model - BL110B The BL110B is a barrier logic unit which has been developed to control barriers using magnetic motors with ease of installation. The BL110B accepts inputs from card readers
More informationMB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR
MB-3688 120A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR User Manual Warning and Precautions MB-3688 is built with corrosion resistant material and the main electronic assembly is well sealed inside
More information115 VAC Control Boxes for
CLASS MODEL SERIAL 8 HP DOORKING CLOSE Wiring / Owner s Manual Use this manual for circuit board 0-00 Revision AA or higher. EXTERNAL ENTRAPMENT PROTECTI MUST be installed or the gate operator WILL NOT
More informationElectrified Products ELECTRIFIED PRODUCTS
Electrified Products Hager Companies offers a range of electrified door hardware to help meet building codes and ensure life safety in every building. From electric door strikes to exit switches and magnetic
More informationFigure 3-9. Right-Hand Port Connector Configuration. 1. Remove electrical power to the Hydraulic Control Unit.
Figure 3-9. Right-Hand Port Connector Configuration Extend and Retract Limit Switch Configuration (if required) 1. Remove electrical power to the Hydraulic Control Unit. WARNING: DO NOT REMOVE OR INSTALL
More informationGENSET CONTROL MODULE LEVEL 1 A121CM / A241CM. Special logic to re-establish cranking following a false start.
Technical Data Sheet GENSET CONTROL MODULE LEVEL 1 A121CM / A241CM Features: Models for both 12V and 24V systems. One model for both spark ignition and diesel engines. 5-alarm light outputs with lamp-test
More informationGENSET CONTROL MODULE A121H / A241H. User selectable time delays for engine start and engine stop (cool down).
Technical Data Sheet GENSET CONTROL MODULE A121H / A241H Features: Models for both 12V and 24V systems. One model for both spark ignition and diesel engines. 4-alarm light outputs with lamp-test provisions.
More informationVARIFAN ELECTRONIC TEMPERATURE/ SPEED CONTROLS
(519) 235-1431 / Fax (519) 235-2852 1-866-335-1431 www.exacon.com VARIFAN ELECTRONIC TEMPERATURE/ SPEED CONTROLS ECS CONTROLS VARIABLE STAGE ALARM CONTACTS MOTOR CURVES HI-LO READINGS TEMP RAMPING 120/240
More informationPRICE LIST - MARCH 2015
PRICE LIST - MARCH 2015 1000 SERIES ELECTROMAGNETIC LOCKS PAGE # #MM300 - MINI-MAGNETIC LOCKS - CABINETS/DRAWERS 2 #1000 - INDUSTRIAL MAGNETIC LOCKS & ACCESSORIES 2 #1100 - MAGNETIC LOCKS - OUTSWING DOORS/
More informationHYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator
HYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator Manufactured by NICE SpA INSTALLATION MANUAL 08/10 CONTENTS IMPORTANT SAFETY INSTRUCTIONS... 3 Applications...... 4 Pre-Installation Checklist... 5
More informationNote: For all general information, refer to Installation and Instruction Manual supplied with the operator.
Installation & Instructions Manual Adding a Timer to Close on a single & 3-phase 115/230/208/460/575V. (Opera series & models MTH/MTBH/GH/MGH/MSJ/MJH/MGT/MSLD/MGSLD) operators Note: For all general information,
More informationfunctions: --Staircase timer --Staircase timer + maintenance function --Staircase timer with early warning
14 SERES 14 SERES Multi-function electronic staircase timers 1 O 16 A 17.5 mm wide Type 14.01 --8 functions --Switch-off early warning options Type 14.71 --3 functions Time setting from 30 seconds to 20
More informationEQ73 Parts list Reference Value Qty Description Marking Dim Manuf. YEL-VIO-BLK-GLD-BRN RED-RED-BRN-BRN RED-RED-BLK-BLK-BRN GRN-BLU-BRN-BRN
EQ73 Parts list (1) Reference Value Qty Description Marking Dim (2) Manuf. R52, R53 47R 2 Resistor 1%, 1/4W YEL-VIO-BLK-GLD-BRN R45, R46 180R 2 Resistor 5%, 1/2W R23, R24 220R 2 Resistor 1%, 1/4W RED-RED-BRN-BRN
More informationInstallation/Owner s Manual 1601 / 1602
CFORMS TO ANSI/UL-325 CERTIFIED TO CAN/CSA C22.2 NO. 247 CLASS HP MODEL SERIAL 53382 VEHICULAR GATE OPERATOR DoorKing, Inc., Inglewood, CA Installation/Owner s Manual 60 / 602 Barrier Gate Operator Use
More informationEmergency Bypass / Shunt Relays (UL924)
Phone: (800) 888-5538 Fax: (765) 883-7505 www.functionaldevices.com sales@functionaldevices.com Bypass / Shunt Relays (UL924) Features Perfect for all emergency shunt lighting applications Up to 16 Amp
More informationINSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:
INSTRUCTION MANUAL IMPORTANT SAFEGUARDS SERIES D LIGHTING EQUIPMENT When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY
More informationCAPTROL MODEL 500 MANUAL # R.F. Capacitance Point Level Switch
CAPTROL MODEL 500 MANUAL # 44493 R.F. Capacitance Point Level Switch 1 was started in 1976 to offer new and innovative electronic designs in tank gauging. L&J s new products always used the latest electronics
More informationB-PC20 Power Close Module
B-PC20 Power Close Module Instruction Manual Document number: B-PC20-C Release: V1.2 Date: OCT 12,2011 ! WARNING This control must be adjusted/serviced by a qualified person. The service technician must
More informationNEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL
NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL PN 610-0012 Rev B Manual No. 610-0012 REV B Neo-Dyn 28150 Industry
More information