IMMERSION. imagination at work. LED Refrigerated Display Lighting. Vertical Cases RV40 Series LED Drivers GEPS4000NCMUL-SY
|
|
- Beatrix James
- 6 years ago
- Views:
Transcription
1 GE Lighting Solutions Installation Guide IMMESION efrigerated isplay Lighting Vertical ases V0 Series 7981 rivers GEPS000NMUL-SY EFOE YOU EGIN ead these instructions completely and carefully. FO YOU SFETY ead and observe all UTIONS and NINGS shown throughout these instructions. Installation to be performed by factory trained service personnel only. For use inside a commercial refrigeration case with packaged foods only. NOTE: This device complies with Part 1 of the F ules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and () this device must accept any interference received, including interference that may cause undesired operation. This lass [] FL complies with the anadian standard IES-00. /e EF de la classe [] est conforme à la NM-00 du anada. NING / VETISSMENT isk of electrical shock. isconnect power before servicing or installing product. etrofit Kit Installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. ontact a qualified electrician. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings. / isque de choc électrique. ouper le courant avant de réparer ou installer le produit. etrofit Kit d'installation nécessite la connaissance des systèmes luminaires électriques. Si vous n'êtes pas qualifié, ne tentez pas l'installation. ontactez un électricien qualifié. Installez ce kit seulement dans les luminaires qui ont les caractéristiques de construction et les dimensions figurant sur les photographies et / ou des dessins. OMPTIILITY This system is compatible with the GEPS000NMUL-SY. Please refer to the separate driver installation guide for appropriate wiring connections. UTION / TTENTION isk of injury. hile performing installations described, gloves, safety glasses or goggles should be worn. / isque de blessure. Lors de l'exécution des installations décrites, des gants, des lunettes de sécurité ou des lunettes de protection doivent être portées.. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.. efore servicing or cleaning unit, switch power off at the service panel and follow appropriate lock out/tag out safety procedures. PEPE ELETIL IING Electrical equirements The power supply must be supplied with V, 0/60 Hz., and connected to an individual properly grounded branch circuit, protected by a 1 or 0 ampere circuit breaker or time delay fuse. iring must be wire with ground and rated for 7 (167 F). ll wiring must be done to NE or local electrical codes. Grounding Instructions able irect This lighting system must be connected to a grounded metal, permanent wiring system, or an equipment grounding conductor must be run with the circuit conductors and be connected to the equipment grounding terminal. imagination at work
2 1 onnect river - Output For retrofit, place driver in the location where the ballast was formerly located. Make output () connections as noted below: OPTION 1 (OEM) USING -Y ONNETO onnect the river output leads to the Light leads using the appropriate mating connector (Molex P/N ). Terminals installed should be crimped using approved tooling and process per Molex specifications. Ensure that the connector cavities are correctly populated per the wire cavity table on page. onnect river - Input Make input () connections using one of the two options below: The river is required to be reliably bonded to the protective ground conductor. OPTION 1 (OEM) - USING -Y ONNETO ttach the supplied green/yellow ground wire from the river to a grounded metal portion of the door frame. onnect the original Line and neutral wires (or Line 1 and Line wires for 0 nominal V) to the -way connector for the river input wires using the appropriate mating connector (Molex P/N ). Ensure that the connector cavities are correctly populated per the wire cavity table on p.. onnect imming ontacts Output OPTION (OEM or ETOFIT) USING TIST-ON IE ONNETOS emove the -way connector from the river by cutting the wires near the connector and strip the output leads. Using the appropriate wiring diagram on page, connect the river output leads to the Light leads using wire connectors or other connection method approved for low temperature usage and stranded cable. () For non-dimming applications, cap the unused wires with /" (mm) twist on wire connectors. For etrofit: undle and safely secure any unused wires by way of approved wire ties and wire connectors. OPTION (OEM or ETOFIT) USING TIST-ON IE ONNETO ttach the supplied green/yellow ground wire from the river to a grounded metal portion of the door frame. emove the -way connector from the river by cutting the wires near the connector and strip the input wires. Using the appropriate wiring diagram on page, connect the original Line and neutral wires (or Line 1 and Line wires for 0 nominal V) to the river leads using twist lock wire connectors or other connection method approved for low temperature usage and stranded cable. Ensure that the connector cavities are correctly populated per wire cavity table on p.. To enable dimming operation, connect leads from occupancy sensor or control system (normally open contact) to the purple and gray leads of the power supply. Make output (contact closure) connections using one of the two options below: OPTION 1 (OEM) USING -Y ONNETO onnect the river dimming output leads to the occupancy sensor or control system using the appropriate mating connector (Molex P/N ). Terminals installed should be crimped using approved tooling and process per Molex specifications. Ensure that the connector cavities are correctly populated per the wire cavity table on page. OPTION (OEM or ETOFIT) USING TIST-ON IE ONNETOS emove the -way connector from the river by cutting the wires near the connector and strip the output leads. Using the appropriate wiring diagram on page, connect the river dimming output leads to the occupancy sensor or control system using wire connectors or other connection method approved for low temperature usage and stranded cable. () The GEPS000NMUL-SY river is capable of step dimming from 100% power to 0% power when used with a normally open contact closure occupancy sensor system. hen using the GEPS000NMUL-SY for non-dimming applications, the dip switch setting must be set to #1 ON to disable the dimming feature and achieve 100% illumination.
3 NING / VETISSMENT isk of electrical shock. Ensure that all connection points are sealed for damp location using the appropriate method per the NE or local electrical code. isque de choc électrique. S assurer que les points de raccordements sont scellés pour emplacement humide en employant une méthode permise par le NE ou par le code électrique local. UTION / TTENTION isk of injury. o not overload river, 60-watts maximum per driver. For 60-inch Lights, do not exceed enter Lights per driver. ( End Lights is equivalent to 1 enter light). For 70-inch Lights, do not exceed enter Lights plus 1 End Light per driver loading limit. isque de blessure. Ne pas surcharger le driver, 60-watts maximum par driver. ans le cas des lampes de 60 "-10 cm, ne pas dépasser lampes centrales par driver. ( lampes latérales équivalent à 1 lampe centrale). ans le cas des lampes de 70"-17 cm, ne pas dépasser lampes centrales et 1 lampe latérale par limite de charge de driver. onnection onfigurations For information on,,,, see Steps 1,, and. One End Set ( & L) Lights SITH Note: Lights are polarity insensitive Two enter Lights SITH Note: Lights are polarity insensitive One enter Light SITH Note: Lights are polarity insensitive IGHT EN LIGHT LEFT EN LIGHT ENTE LIGHT ENTE LIGHT ENTE LIGHT HITE (NEUTL) LK (LINE) TEMINL LOK TEMINL ( Source) LOK HITE (NEUTL) LK (LINE) TEMINL LOK TEMINL ( Source) LOK HITE (NEUTL) LK (LINE) TEMINL LOK TEMINL ( Source) LOK One End Set (ight and Left) & One enter Light One End Light (ight or Left) & One enter Light SITH Note: Lights are polarity insensitive IGHT EN LIGHT LEFT EN LIGHT ENTE LIGHT SITH Note: Lights are polarity insensitive EN ( or L) LIGHT ENTE LIGHT ire avities () avity 1 - Line 1 (lack) avity - Earth Ground (Green) avity - Neutral or Line (hite) () avity 1 - Output (+) (red) avity - Output (-) (black) avity - imming (Purple) avity - imming (Gray) HITE (NEUTL) LK (LINE) TEMINL LOK TEMINL ( Source) LOK HITE (NEUTL) LK (LINE) TEMINL LOK TEMINL ( Source) LOK
4 GE Lighting Solutions etrofit Installation Guide IMMESION efrigerated isplay Lighting Vertical ases V0 Series End Mullion Lights 8-inch: GELT080E-SY/-S (660/6606), GELT080E-SY/-S (6609/661), GELT08E-SY/-S (661/6618), GELT080EL-SY/-S (660/6607), GELT080EL-SY/-S (6610/661) & GELT08EL-SY/-S (6616/6619) 60-inch: GELT060E-SY/-S (797/7977), GELT0600E-SY/-S (7978/7971), GELT0600E-SY/-S (797/797), GELT060EL-SY/-S (797/7978), GELT0600EL-SY/-S (7979/797) & GELT0600EL-SY/-S (797/7976) 70-inch: GELT070E-SY/-S (7977/7977), GELT0700E-SY/-S (79766/79769), GELT0700E-SY/-S (79760/7976) GELT070EL-SY/-S (7977/79776), GELT0700EL-SY/-S (79767/79770) & GELT0700EL-SY/-S (79761/7976), escription ode (Single Unit Product Number / 10-Pack Product Number) EFOE YOU EGIN ead these instructions completely and carefully. FO YOU SFETY ead and observe all UTIONS and NINGS shown throughout these instructions. Installation to be performed by factory trained service personnel only. For use inside a commercial refrigeration case with packaged foods only. NOTE: This device complies with Part 1 of the F ules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and () this device must accept any interference received, including interference that may cause undesired operation. This lass [] FL complies with the anadian standard IES-00. e EF de la classe [] est conforme à la NM-00 du anada. NING / VETISSMENT isk of electrical shock. isconnect power before servicing or installing product. etrofit Kit Installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. ontact a qualified electrician. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings. / isque de choc électrique. ouper le courant avant de réparer ou installer le produit. etrofit Kit d'installation nécessite la connaissance des systèmes luminaires électriques. Si vous n'êtes pas qualifié, ne tentez pas l'installation. ontactez un électricien qualifié. Installez ce kit seulement dans les luminaires qui ont les caractéristiques de construction et les dimensions figurant sur les photographies et / ou des dessins. OMPTIILITY This system is compatible with the GEPS000NMUL-SY. Please refer to the separate driver installation guide for appropriate wiring connections. UTION / TTENTION isk of injury. hile performing installations described, gloves, safety glasses or goggles should be worn. / isque de blessure. Lors de l'exécution des installations décrites, des gants, des lunettes de sécurité ou des lunettes de protection doivent être portées.. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.. efore servicing or cleaning unit, switch power off at the service panel and follow appropriate lock out / tag out safety procedures. PEPE ELETIL IING Electrical equirements The power supply must be supplied with V, 0/60 Hz., and connected to an individual properly grounded branch circuit, protected by a 1 or 0 ampere circuit breaker or time delay fuse. iring must be wire with ground and rated for 7 (167 F). o not overload driver, follow installation instructions for the GEPS000NMUL-SY. Ensure that all connection points are sealed for damp location using the appropriate method per the NE or local electrical code. Grounding Instructions able irect This lighting system must be connected to a grounded metal, permanent wiring system, or an equipment grounding conductor must be run with the circuit conductors and be connected to the equipment grounding terminal. imagination at work
5 1 emove Existing Lighting omponents Tools equired omponents equired ire stripper/cutter Tape measure Screwdriver ordless drill Hammer 7/6-inch (.8mm) drill bit enter punch 1 light driver ire cover 6- x 1/" screws Twist lock splice wire connectors For retrofit only. If you are an OEM, please refer to the OEM Installation Guide. Fluorescent omponent Location efer to manufacturing manual for refrigeration case to identify lighting control circuits. Ensure that power is switched off at the service panel for the lighting circuit. If a lighting power switch is not provided in the refrigeration case, power removal can be performed at the main breaker panel. Locate existing lighting components including ballasts, lampholders, lamps, and lampguards in the refrigeration case for removal. Please refer to refrigeration manual for any questions dealing with component locations. 1 emove lamps, lampholder and lamp guards. ut the wiring, making the cut as close to the lampholder as possible. o not remove wiring from case as it will be utilized to attach the light. ispose of components per federal and local regulations. Locate ballast within system. The most common location is in the mullion or the electrical raceway found in the bottom of the refrigerated case. isconnect ballast input and output connectors. ut the ballast connector wires nearest to the connector and remove connector. Unscrew the mounting screws that attach ballast and remove ballast. ispose of ballasts according to federal and local regulations. driver installation will begin at Step 7 and Step 8. To install the light, first identify the wiring for connection to the driver. fter removing the connector from ballast, leave the existing ballast input and output wires for reconnection in a later step. Lamp with lamp guards (behind mullion) Lamp holders allast 1. Mullion. aceway. Overhead door frame
6 UTION / TTENTION isk of damage to unit. Prior to drilling make sure that there are no existing components inside the mullion in the areas marked off for the designated holes. / isque d'endommager l'unité. vant de percer, faire en sorte qu'il n'y ait pas de composantes dans la cloison dans les zones délimitées et identifiées pour le perçage. isk of damage to unit. To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. / isque d'endommager l'unité. Pour éviter l'endommagement de câblage ou l'abrasion, ne pas exposer le câblage aux bords de feuilles de métal ou d'autres objets tranchants. Prepare for Installation of End Lights Measure 1 /-inches (8 mm) from the edge of the mullion nearest the door, and mark a vertical line near the top and bottom of the frame mullion. Left End Shield river Leads 1-/" (8 mm) 1-/" (8 mm) ight End Shield 1/8" ( mm) Prepare for the upper end of the End Light. Mark a horizontal line a minimum 1/8-inches ( mm) from the top of the door opening, and another horizontal line /8-inches (10 mm) below this line. /8" (10 mm) Prepare for the lower end of the End Light. For 8-inch Lights mark a horizontal line 6 1/" (117mm) beneath the first line drawn for the top Mounting. For 60-inch Lights, mark a horizontal line 8 /-inches (176 mm) beneath the first line drawn for the top Mounting Tab. For 70-inch Lights, mark a horizontal line 68 1/" (179 mm) beneath the first line drawn for the top Mounting Tab. Then mark another line /8-inches (10 mm) below this line. enter Punch at Intersection and drill a 7/6-inch (.8 mm) hole For 8-inch Lights: 6 1/" (117 mm) For 60-inch Lights: 8 /" (176 mm) For 70-inch Lights: 68 1/" (179 mm) /8" (10 mm) enter the center punch directly at the intersection of the horizontal lines and the vertical line (top and bottom) and establish a dimple. End Mullion - Left End Mullion - ight View from inside the case looking out Use power drill and 7/6-inch (.8 mm) drill bit to drill holes at the intersection of the vertical center line and the horizontal lines. epeat these steps for the mullion on the other end of the case.
7 ire EL E Identify End Light - ight from Left ire Verify s are directed towards the center of the case before installing. NOTE: Installing the Light on the wrong side will result in very low light level inside the refrigerated case. View from inside the case looking out NING / VETISSMENT isk of electrical shock. Only those open holes indicated in the photographs and/or drawings may be made or altered as a result of kit installation. o not leave any other open holes in an enclosure of wiring or electric components / isque de choc électrique. Seuls les trous ouverts indiqués dans les photos et / ou les dessins peuvent être faites ou modifiés à la suite du montage du kit. Ne pas laisser autres trous ouverts dans l'enceinte du câblage électrique ou composants. Install End Lights river Place proper End Light against the face of the mullion near the two holes drilled at the top. NOTE: efer to proper End Light orientation depicted in Step. Insert a #6- x 1/-inch sheet metal screw into the slot of the Mounting Tab on the End Light, and into the first hole that was drilled in the end mullion. Use a screwdriver to start threading the screw into the drilled hole. End Light Power Leads Output Leads epeat for the second screw, and for the bottom of the End Light. Mounting Tab efer to the manufacturing manual for door frame to ensure there are no components contained inside the mullion that could be drilled through. Use a #6 - /-inch self-drilling screw to attach the enter Light into one or two of the additional mounting holes located near the center of the Light. efer to wiring diagram on page 6. onnect the red and black output wires from the Light to the red and black wires on the river using the twist lock splice wire connectors provided.
8 UTION / TTENTION isk of injury. o not overload river, 60-watts maximum per driver. For 8-inch Lights, do not exceed enter Lights per driver loading limit. ( End Lights is equivalent to 1 enter Light). For 60-inch Lights, do not exceed enter Lights per driver. ( End Lights is equivalent to 1 enter light). For 70-inch Lights, do not exceed enter Lights plus 1 End Light per driver loading limit. isque de blessure. Ne pas surcharger le driver, 60-watts maximum par driver. ans le cas des lampes de 8"-1 cm, ne pas dépasser lampes centrales par limite de charge du driver. ( lampes latérales équivalent à 1 lampe centrale). ans le cas des lampes de 60"- 1 cm, ne pas dépasser lampes centrales par limite de charge du driver. ( lampes latérales équivalent à 1 lampe centrale). ans le cas des lampes de 70"-17 cm, ne pas dépasser lampes centrales et 1 lampe latérale par limite de charge de driver. river onfiguration Options The diagrams below represent wiring configurations for each river. 6-oor ase For 8" Lights For 60" & 70" Lights -oor ase -oor ase For 8" Lights For 60" & 70" Lights For 8" Lights For 60" & 70" Lights -oor ase -oor ase For 8" Lights For 60" & 70" Lights For 8", 60" & 70" Lights Parts Needed Per ase 6-oor -oor -oor -oor -oor enter Lights 1 End Light Sets rivers (60-inch Lights) 1 1 rivers (70-inch Lights) 1 rivers (8-inch Lights ire overs 7 6
9 NING / VETISSMENT isk of electrical shock. Ensure that all connection points are sealed for damp location using the appropriate method per the NE or local electrical code. isque de choc électrique. S assurer que les points de raccordements sont scellés pour emplacement humide en employant une méthode permise par le NE ou par le code électrique local. onnection onfigurations For information on,,,, see Steps, 6, and 7. One End Set ( & L) Lights SITH Note: Lights are polarity insensitive Two enter Lights SITH Note: Lights are polarity insensitive One enter Light SITH Note: Lights are polarity insensitive IGHT EN LIGHT LEFT EN LIGHT HITE (NEUTL) LK (LINE) TEMINL LOK TEMINL ( Source) LOK HITE (NEUTL) LK (LINE) TEMINL LOK TEMINL ( Source) LOK One End Set (ight and Left) & One enter Light One End Light (ight or Left) & One enter Light SITH Note: Lights are polarity insensitive SITH Note: Lights are polarity insensitive IGHT EN LIGHT LEFT EN LIGHT ENTE LIGHT EN ( or L) LIGHT ENTE LIGHT ENTE LIGHT ENTE LIGHT ENTE LIGHT HITE (NEUTL) LK (LINE) TEMINL LOK TEMINL ( Source) LOK HITE (NEUTL) LK (LINE) TEMINL LOK TEMINL ( Source) LOK HITE (NEUTL) LK (LINE) TEMINL LOK TEMINL ( Source) LOK 6
10 onnect river - Output For etrofit, place driver in the location where the ballast was formerly located. Make output () connections as noted below: USING TIST-ON IE ONNETOS emove the -way connector from the river by cutting the wires near the connector and strip the output leads. Using the appropriate wiring diagram on page 6, connect the river output leads to the Light leads. Use an ohm meter to identify the two wires connected to the Light that measure between ~ 1,000-18,000 ohms. Use wire connectors or other connection method approved for low temperature usage and stranded cable. () For non-dimming applications, cap the unused wires with /" (mm) twist on wire connectors. undle and safely secure any unused wires by way of approved wire ties and wire connectors. 6 onnect river - Input Make input () connections as noted below: USING TIST-ON IE ONNETO The river is required to be reliably bonded to the protective ground conductor. ttach the supplied green/yellow ground wire from the river to a grounded metal portion of the door frame. emove the -way connector from the river by cutting the wires near the connector and strip the input wires. Using the appropriate wiring diagram on page 6, connect the original Line and neutral wires (or Line 1 and Line wires for 0 nominal V) to the river leads using the provided twist lock splice wire connectors or other connection method approved for low temperature usage and stranded cable. () 7 onnect imming ontacts Output (Optional) To enable dimming operation, connect leads from occupancy sensor or control system (normally open contact) to the purple and gray leads of the power supply. Make output (contact closure) connections using one of the two options below: USING TIST-ON IE ONNETOS emove the -way connector from the river by cutting the wires near the connector and strip the output leads. Using the appropriate wiring diagram on page 6, connect the river dimming output leads to the occupancy sensor or control system using wire connectors or other connection method approved for low temperature usage and stranded cable. () The river is capable of step dimming from 100% power to 0% power when used with a normally open contact closure occupancy sensor system. hen using the drivers for non-dimming applications, the dip switch setting must be set to #1 ON to disable the dimming feature and achieve 100% illumination. 7
11 UTION / TTENTION isk of electrical shock. Plastic cover is needed to protect electrical wires from tampering and accidental contact. / isque de choc électrique. Le couvercle en plastique est requis pour assurer une protection adéquate contre l'accès aux fils et les contacts accidentels. ire 8 ttach overs to Mounting Tab over Tuck wires underneath ire over before placing it over the End ap and Mounting Tab. ttach ire over to Light Mounting Tab by installing a M.9x10 pan head tapping screw (provided) through the hole in the End ap and Mounting Tab using an installation torque of lbf-in. NOTE: Tighten slowly until fully seated, do not over tighten or strip the threads. epeat these steps for the mullion on the other end of the case. End ap M.9x10 pan head tapping screw NING / VETISSMENT isk of electrical shock. isconnect power to Lights before any cleaning operation. isque de choc électrique. ébranchez l'alimentation des éclairages à avant toute opération de nettoyage. 9 efigerated isplay Lights leaning Instructions The outer lens and the plastic housing should be cleaned periodically with a mild liquid dish detergent. o not use chemical cleaners to clean the lens. Keep the outside clean. ipe with a clean cloth lightly dampened with mild liquid dish detergent. ry with a clean, soft cloth. o not wipe the lens with a soiled dish cloth or wet towel. These may leave a residue that can damage the finish. o not use scouring pads, powdered cleaners, bleach or cleaners containing bleach because these products can scratch and damage the finish. GE Lighting Solutions MY-GE GE Lighting Solutions, LL is a subsidiary of the General Electric ompany. Immersion is a trademark of GE Lighting Solutions, LL. The GE brand and logo are trademarks of the General Electric ompany. 011 GE Lighting Solutions, LL. Information provided is subject to change without notice. ll values are design or typical values when measured under laboratory conditions. 8 ISP
12 GE Lighting Solutions etrofit Installation Guide IMMESION efrigerated isplay Lighting Vertical ases V0 Series enter Mullion Lights 8-inch: GELT080T-SY/-S (660/660), GELT080T-SY/-S (6608/6611), GELT08T-SY/-S (661/6617) 60-inch: GELT060T-SY/-S (797/7976), GELT0600T-SY/-S (7977/7970) & GELT0600T-SY/-S (7971/797) 70-inch: GELT070T-SY/-S (79771/7977), GELT0700T-SY/-S (7976/79768), GELT0700T-SY/-S (7979/7976) escription ode (Single Unit Product Number / 10-Pack Product Number) EFOE YOU EGIN ead these instructions completely and carefully. FO YOU SFETY ead and observe all UTIONS and NINGS shown throughout these instructions. Installation to be performed by factory trained service personnel only. For use inside a commercial refrigeration case with packaged foods only. NOTE: This device complies with Part 1 of the F ules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and () this device must accept any interference received, including interference that may cause undesired operation. This lass [] FL complies with the anadian standard IES-00. /e EF de la classe [] est conforme à la NM-00 du anada. OMPTIILITY This system is compatible with the GEPS000NMUL-SY. Please refer to the separate driver installation guide for appropriate wiring connections. NING / VETISSMENT isk of electrical shock. isconnect power before servicing or installing product. etrofit Kit Installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. ontact a qualified electrician. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings. / isque de choc électrique. ouper le courant avant de réparer ou installer le produit. etrofit Kit d'installation nécessite la connaissance des systèmes luminaires électriques. Si vous n'êtes pas qualifié, ne tentez pas l'installation. ontactez un électricien qualifié. Installez ce kit seulement dans les luminaires qui ont les caractéristiques de construction et les dimensions figurant sur les photographies et / ou des dessins. UTION / TTENTION isk of injury. hile performing installations described, gloves, safety glasses or goggles should be worn. / isque de blessure. Lors de l'exécution des installations décrites, des gants, des lunettes de sécurité ou des lunettes de protection doivent être portées.. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.. efore servicing or cleaning unit, switch power off at the service panel and follow appropriate lock out/tag out safety procedures. PEPE ELETIL IING Electrical equirements The power supply must be supplied with V, 0/60 Hz., and connected to an individual properly grounded branch circuit, protected by a 1 or 0 ampere circuit breaker or time delay fuse. iring must be wire with ground and rated for 7 (167 F). o not overload driver, follow installation instructions for the GEPS000NMUL-SY. Ensure that all connection points are sealed for damp location using the appropriate method per the NE or local electrical code. Grounding Instructions able irect This lighting system must be connected to a grounded metal, permanent wiring system, or an equipment grounding conductor must be run with the circuit conductors and be connected to the equipment grounding terminal. imagination at work
13 1 emove Existing Lighting omponents Tools equired omponents equired ire stripper/cutter Tape measure Screwdriver ordless drill Hammer 7/6-inch (.8mm) drill bit enter punch 1 light driver ire cover 6- x 1/" screws Twist lock splice wire connectors For retrofit only. If you are an OEM, please refer to the OEM Installation Guide. Fluorescent omponent Location efer to manufacturing manual for refrigeration case to identify lighting control circuits. Ensure that power is switched off at the service panel for the lighting circuit. If a lighting power switch is not provided in the refrigeration case, power removal can be performed at the main breaker panel. Locate existing lighting components including ballasts, lampholders, lamps, and lampguards in the refrigeration case for removal. Please refer to refrigeration manual for any questions dealing with component locations. 1 emove lamps, lampholder and lamp guards. ut the wiring, making the cut as close to the lampholder as possible. o not remove wiring from case as it will be utilized to attach the light. ispose of components per federal and local regulations. Locate ballast within system. The most common location is in the mullion or the electrical raceway found in the bottom of the refrigerated case. isconnect ballast input and output connectors. ut the ballast connector wires nearest to the connector and remove connector. Unscrew the mounting screws that attach ballast and remove ballast. ispose of ballasts according to federal and local regulations. driver installation will begin at Step and Step 6. To install the light, first identify the wiring for connection to the driver. fter removing the connector from ballast, leave the existing ballast input and output wires for reconnection in a later step. Lamp with lamp guards (behind mullion) Lamp holders allast 1. Mullion. aceway. Overhead door frame
14 UTION / TTENTION isk of damage to unit. Prior to drilling make sure that there are no existing components inside the mullion in the areas marked off for the designated holes. / isque d'endommager l'unité. vant de percer, faire en sorte qu'il n'y ait pas de composantes dans la cloison dans les zones délimitées et identifiées pour le perçage. isk of damage to unit. To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. / isque d'endommager l'unité. Pour éviter l'endommagement de câblage ou l'abrasion, ne pas exposer le câblage aux bords de feuilles de métal ou d'autres objets tranchants. Prepare for Installation of enter Lights Measure the total width of the mullion, and mark a vertical line half the total width near the top and bottom of the mullion. Prepare for the upper end of the enter Light. Mark a horizontal line a minimum 1/8-inches ( mm) from the top of the mullion, and another horizontal line /8-inch (10 mm) below this line. Prepare for the lower end of the enter Light. For 8-inch Lights mark a horizontal line 6 1/" (117mm) beneath the first line drawn for the top Mounting. For 60-inch Lights, mark a horizontal line 8 /-inches (176 mm) beneath the first line drawn for the top Mounting Tab. For 70-inch Lights, mark a horizontal line 68 1/" (179 mm) beneath the first line drawn for the top Mounting Tab. Half total width of mullion /8" ( 10 mm) enter punch at intersection and drill a 7/6-inch (.8 mm) hole Total width of mullion river wires - top top For 8-inch Lights: 6 1/" (117mm) For 60-inch Lights: 8 /" (176 mm) For 70-inch Lights: 68 1/" (179 mm) enter the center punch directly at the intersection of the horizontal lines and the vertical line (top and bottom) and establish a dimple. Use power drill and 7/6-inch (.8 mm) drill bit to drill holes at the intersection of the vertical and horizontal center line. NING / VETISSMENT isk of electrical shock. Only those open holes indicated in the photographs and/or drawings may be made or altered as a result of kit installation. o not leave any other open holes in an enclosure of wiring or electric components / isque de choc électrique. Seuls les trous ouverts indiqués dans les photos et / ou les dessins peuvent être faites ou modifiés à la suite du montage du kit. Ne pas laisser autres trous ouverts dans l'enceinte du câblage électrique ou composants. Install enter Lights Place a enter Light against the back face of the mullion near the two holes drilled at the top. Insert a #6- x 1/-inch sheet metal screw into the top slot of the Mounting Tab on the enter Light and into the first hole that was drilled in the center mullion. Use a screwdriver to thread the screw into the drilled hole. epeat for the second screw, and for the lower end of the enter Light. efer to the manufacturing manual for door frame to ensure there are no components contained inside the mullion that could be drilled through. Use a #6 - /-inch self-drilling screw to attach the enter Light into one or two of the additional mounting holes located near the center of the Light. efer to wiring diagram on page. onnect the red and black output wires from the Light to the red and black wires on the river using the twist lock splice wire connectors provided. enter Light Power Leads river Leads Mounting Tab
15 UTION / TTENTION isk of injury. o not overload river, 60-watts maximum per driver. For 8-inch Lights, do not exceed enter Lights per driver loading limit. ( End Lights is equivalent to 1 enter Light). For 60-inch Lights, do not exceed enter Lights per driver. ( End Lights is equivalent to 1 enter light). For 70-inch Lights, do not exceed enter Lights plus 1 End Light per driver loading limit. isque de blessure. Ne pas surcharger le driver, 60-watts maximum par driver. ans le cas des lampes de 8"-1 cm, ne pas dépasser lampes centrales par limite de charge du driver. ( lampes latérales équivalent à 1 lampe centrale). ans le cas des lampes de 60"- 1 cm, ne pas dépasser lampes centrales par limite de charge du driver. ( lampes latérales équivalent à 1 lampe centrale). ans le cas des lampes de 70"-17 cm, ne pas dépasser lampes centrales et 1 lampe latérale par limite de charge de driver. river onfiguration Options The diagrams below represent wiring configurations for each river. 6-oor ase For 8" Lights For 60" & 70" Lights -oor ase -oor ase For 8" Lights For 60" & 70" Lights For 8" Lights For 60" & 70" Lights -oor ase -oor ase For 8" Lights For 60" & 70" Lights For 8", 60" & 70" Lights Parts Needed Per ase 6-oor -oor -oor -oor -oor enter Lights 1 End Light Sets rivers (60-inch Lights) 1 1 rivers (70-inch Lights) 1 rivers (8-inch Lights ire overs 7 6
16 NING / VETISSMENT isk of electrical shock. Ensure that all connection points are sealed for damp location using the appropriate method per the NE or local electrical code. isque de choc électrique. S assurer que les points de raccordements sont scellés pour emplacement humide en employant une méthode permise par le NE ou par le code électrique local. onnection onfigurations For information on,,,, see Steps, 6, and 7. One End Set ( & L) Lights SITH Note: Lights are polarity insensitive Two enter Lights SITH Note: Lights are polarity insensitive One enter Light SITH Note: Lights are polarity insensitive IGHT EN LIGHT LEFT EN LIGHT HITE (NEUTL) LK (LINE) TEMINL LOK TEMINL ( Source) LOK HITE (NEUTL) LK (LINE) TEMINL LOK TEMINL ( Source) LOK One End Set (ight and Left) & One enter Light One End Light (ight or Left) & One enter Light SITH Note: Lights are polarity insensitive SITH Note: Lights are polarity insensitive IGHT EN LIGHT LEFT EN LIGHT ENTE LIGHT EN ( or L) LIGHT ENTE LIGHT ENTE LIGHT ENTE LIGHT ENTE LIGHT HITE (NEUTL) LK (LINE) TEMINL LOK TEMINL ( Source) LOK HITE (NEUTL) LK (LINE) TEMINL LOK TEMINL ( Source) LOK HITE (NEUTL) LK (LINE) TEMINL LOK TEMINL ( Source) LOK
17 onnect river - Output For etrofit, place driver in the location where the ballast was formerly located. Make output () connections as noted below: USING TIST-ON IE ONNETOS emove the -way connector from the river by cutting the wires near the connector and strip the output leads. Using the appropriate wiring diagram on page, connect the river output leads to the Light leads. Use an ohm meter to identify the two wires connected to the Light that measure between ~ 1,000-18,000 ohms. Use wire connectors or other connection method approved for low temperature usage and stranded cable. () For non-dimming applications, cap the unused wires with /" (mm) twist on wire connectors. undle and safely secure any unused wires by way of approved wire ties and wire connectors. 6 onnect river - Input Make input () connections as noted below: USING TIST-ON IE ONNETO The river is required to be reliably bonded to the protective ground conductor. ttach the supplied green/yellow ground wire from the river to a grounded metal portion of the door frame. emove the -way connector from the river by cutting the wires near the connector and strip the input wires. Using the appropriate wiring diagram on page, connect the original Line and neutral wires (or Line 1 and Line wires for 0 nominal V) to the river leads using the provided twist lock splice wire connectors or other connection method approved for low temperature usage and stranded cable. () 7 onnect imming ontacts Output (Optional) To enable dimming operation, connect leads from occupancy sensor or control system (normally open contact) to the purple and gray leads of the power supply. Make output (contact closure) connections using one of the two options below: USING TIST-ON IE ONNETOS emove the -way connector from the river by cutting the wires near the connector and strip the output leads. Using the appropriate wiring diagram on page, connect the river dimming output leads to the occupancy sensor or control system using wire connectors or other connection method approved for low temperature usage and stranded cable. () The river is capable of step dimming from 100% power to 0% power when used with a normally open contact closure occupancy sensor system. hen using the drivers for non-dimming applications, the dip switch setting must be set to #1 ON to disable the dimming feature and achieve 100% illumination. 6
18 UTION / TTENTION isk of electrical shock. Plastic cover is needed to protect electrical wires from tampering and accidental contact. / isque de choc électrique. Le couvercle en plastique est requis pour assurer une protection adéquate contre l'accès aux fils et les contacts accidentels. 8 ttach overs to Mounting Tab Tuck wires underneath ire over before installing it onto the End ap. ttach ire over to Light Mounting Tab by inserting a M.9x10 pan head tapping screw (provided) through the holes in overs and Mounting Tabs using an installation torque of lbf-in. ire over NOTE: Tighten slowly until fully seated, do not over tighten or strip the threads. M.9x10 pan head tapping screw Mounting Tab NING / VETISSMENT isk of electrical shock. isconnect power to Lights before any cleaning operation. isque de choc électrique. ébranchez l'alimentation des éclairages à avant toute opération de nettoyage. 9 efigerated isplay Lights leaning Instructions The outer lens and the plastic housing should be cleaned periodically with a mild liquid dish detergent. o not use chemical cleaners to clean the lens. Keep the outside clean. ipe with a clean cloth lightly dampened with mild liquid dish detergent. ry with a clean, soft cloth. o not wipe the lens with a soiled dish cloth or wet towel. These may leave a residue that can damage the finish. o not use scouring pads, powdered cleaners, bleach or cleaners containing bleach because these products can scratch and damage the finish. GE Lighting Solutions MY-GE GE Lighting Solutions, LL is a subsidiary of the General Electric ompany. Immersion is a trademark of GE Lighting Solutions, LL. The GE brand and logo are trademarks of the General Electric ompany. 011 GE Lighting Solutions, LL. Information provided is subject to change without notice. ll values are design or typical values when measured under laboratory conditions. 7 ISP
IMMERSION. imagination at work. Retrofit Installation Guide. GE Lighting. LED Refrigerated Display Lighting
GE Lighting etrofit Installation Guide IMMESION efrigerated isplay Lighting Vertical ases V0 Series End Mullion Lights 8-inch: GELT080E-SY/-S (6603/6606), GELT080E-SY/-S (6609/6612), GELT083E-SY/-S (661/6618),
More informationIMMERSION. GE Lighting. OEM Installation Guide. imagination at work. LED Display Lighting
GE Lighting OEM Installation Guide IMMESION isplay Lighting efrigerated Vertical Cases V0 Series End Mullion Lights 750 mm (0-inch): GELT0050E-SY/-S (79778/79781), GELT0050EL-SY/-S (79779/7978), GELT000E-SY/-S
More informationELV1abbccd-e. Color Temperature: 30 = 3000K White 35 = 3500K White 40 = 4000K White 45 = 4500K White 50 = 5000K White
GE Lighting Immersion TM Elite LED Refrigerated Display Lighting End Mullion Lights for Vertical Cases Installation Guide ELV1abbccd-e Prefix: EL = Elite V = Vertical FD = French Door 1 = Generation Light
More informationREAD AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION
UR Series LED Upgrade Kit Includes: 24" Linear Option IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL
More informationIMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:
ZR-RK Series LED Retrofit Troffer Kit Includes: ZR22RK and ZR24RK Standard and Emergency Luminaires IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed
More informationINSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F
SAFETY S IMPORTANT SAFETY INFORMATION SUITABLE FOR DRY OR DAMP LOCATIONS. NOT FOR USE WITH PHASE CUT DIMMERS. Risk of shock. Disconnect power before installation. DANGER CONVIENT AUX EMPLACEMENTS HUMIDES.
More informationINSTALLATION GUIDE Works in double and single ended wiring.
ISTAATIO GUIDE Works in double and single ended wiring. -1- Safety Precautions For your and others safety, please read the precaution carefully before installation: (1). Product should be installed by
More informationSpecification Grade Contemporary Wall Mount/Technical Installation Data
AVAILABLE CONFIGURATIONS RECESSED MOUNT SURFACE MOUNT MOUNTING REQUIREMENTS A. Recessed Mount: Minimum 4-Gang Box, 1-5/8 in. Deep (72.8 Cubic Inches) with 4-Gang Box Cover (20.3 Cubic Inches) B. Surface
More informationINSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit
INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit TRMUNV065ECxyyZ TRAUNV065ECxyyZ Installation Instructions subject to change without notice. Page 1 of 8 1.0 INSTALLATION WARNINGS 1. 2. 3. 4. 5. 6. "THIS
More informationLUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed
Installation Guide LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed Installation Description The LUNERA VERTICAL E26 LED FLOODLIGHT is a line driven
More informationINSTALLATION INSTRUCTIONS
INDIGO-CLEAN TECHNOLOGY RETROFIT KIT INSTALLATION INSTRUCTIONS 1 IMPORTANT SAFETY INFORMATION Risk of shock. Disconnect power before installation. DANGER- RISQUE DE CHOC- COUPER L ALIMENTATION AVANT L
More informationCaptivate Illuminated Mirror Light
ENGLISH WARNINGS & SAFETY INFORMATION: PLEASE READ CAREFULLY FRANÇAIS MISES EN GARDE ET SÉCURITÉ: SE IL VOUS PLAÎT LIRE ATTENTIVEMENT WARNING: RISK OF FIRE OR ELECTRIC SHOCK. LUMINAIRE WIRING AND ELECTRICAL
More informationINSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.
INSTALLATION INSTRUCTIONS SUPERPLANE 2.5 Suspended A 1035 22nd Avenue, Unit 1 Oakland, CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com SP2.5S - Safety & Warnings! 1. Read all instructions. 2.
More informationINSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.
Oakland, INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5 LP3.5 Suspended LED A 1035 22nd Avenue, Unit 1 n CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com Safety & Warnings! 1. Read all instructions.
More informationMOONRING 1.5 MOONRING 3
INSTALLATION INSTRUCTIONS MOONRING 1.5 MOONRING 3 MR1.5 & MR3 Suspended, Ceiling LED n A 1035 22nd Avenue, Unit 1 Oakland, CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com Safety & Warnings!
More informationINSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1
INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1 Suspended, Ceiling LED n A 1035 22nd Avenue, Unit 1 Oakland, CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com Safety & Warnings! 1. Read all instructions.
More informationTetra minimax. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide
Installation Guide Volt Tetra minimax LED Lighting System GEMMRD-W, GEMMGL-W, GEMMBL-W BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSMENT RISK OF ELECTRIC SHOCK Turn
More informationMAXLITE RKT LED Retrofit Kit
MAXLITE RKT LED Retrofit Kit Description and Intended Use The RKT LED Retrofit Kit is a high performance LED Fixture upgrade kit designed to replace the original components inside 2 x2 and 2 x4 fluorescent
More informationCable Cubby 1202 and 1402 Installation Guide
Cable Cubby 0 and 40 Installation Guide IMPORTANT: Go to www.extron.com for the complete user guide, installation instructions, and specifications. This guide provides instructions for an experienced technician
More informationLS1 SERIES IMPORTANT: READ ALL INSTRUCTIONS THOROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF LINEAR SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE.
The LS1 Series of commercial and industrial LED fixtures is designed to be used in utility strip applications using suspension or surface mount installation. The LS1 Series is designed for use in 120 277V,
More informationWARNING/AVERTISSEMENT. Coupez l alimentation électrique à la boîte de fusibles ou au disjoncteur avant servicing or installing product.
Tetra Contour LS LED Lighting System GEXNLBL-1, GEXNLGL-1, GEXNLRD-1, GEXNL65-1, GEXNL32-1 Installation Guide 24 Volt BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSEMENT
More informationLumination TM LED Luminaires LAL Series - Continuous Run Option
GE Lighting Installation Guide Lumination TM LED Luminaires LAL Series - Continuous Run Option BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSEMENT RISK OF ELECTRIC
More informationOPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS
OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS 99-24283-I001 Table of Contents 1. 24V LED Approved Drivers 5 1.1. 24V LED Driver (60-19910-0002).. 5 2. Optimax Radiant 24V LED Lighting. 6 2.1. OP30 6 2.2.
More informationINSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing
SAFETY INSTRUCTIONS IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation by a qualified electrician in accordance
More informationLumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame
Installation Guide Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame BEFORE YOU BEGIN Read these instructions completely and carefully. RISK OF ELECTRIC SHOCK Turn power off before
More informationAnthony LED Lighting System Retrofit Installation Instructions For Models 101X and 101A
Anthony LED Lighting System Retrofit Installation Instructions For Models 101X and 101A 99-16999-0000 Table of Contents 1. Removing Fluorescent Lighting... 4 1.1. Detach the lens assembly... 4 1.2. Remove
More informationWet Rated Batten LED Luminaire
Installation Guide Wet Rated Batten LED Luminaire LED Lighting System BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING / AVERTISSEMENT RISK OF ELECTRIC SHOCK Turn power off before
More informationCable Cubby 650 UT Installation Guide
e NT: RTA.com for thtion O P IM tron talla w.ex uide, ins ations. o ww Go t te user g specific nd ple com ctions, a u instr Cable Cubby 650 UT Installation Guide This guide provides instructions for an
More informationQuick Installation Guide. Affinium LED Modules LFM300 for Refrigerated Display Cases
Quick Installation Guide Affinium LED Modules LFM300 for Refrigerated Display Cases Important Please take the time to read this installation guide before you install the Affinium LED modules and LED power
More informationAlbeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)
GE Lighting Installation Guide Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series) Features UL 1598 Suitable for Wet Locations IP66 Rated Ingress Protection BEFORE YOU BEGIN Read these
More informationLED Recessed Troffer Retrofit Kit
Model # TRK series LED Recessed Troffer Retrofit Kit Installation Instructions PACKAGE CONTENTS A B E Part Item Name Qty. A Retrofit assembly 1 B Bracket 2 C Sheet metal screw 4 D Wire nuts 5 E Gap channel
More informationLumination TM LED Luminaire LUR Series
Installation Guide Lumination TM LED Luminaire LUR Series BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSEMENT RISK OF FIRE OR ELECTRIC SHOCK Turn power off before inspection,
More informationCable Cubby 1200 and 1400 Installation Guide
e NT: R.com for thtion O P IM tron talla w.ex uide, ins ations. o ww Go t te user g specific nd ple com ctions, a u instr 00 and 400 Installation Guide This guide provides instructions for an experienced
More informationpoollux Power plx-pw60 & plx-pw100
poollux Power plx-pw60 & plx-pw100 ETL LISTED Conforms to UL STD 379; Certifi.ed.to.CSA.STD.C22.2.#218.1 5005508 Installation Instructions Read all instructions before attempting to perform installation
More informationLumination TM LED Luminaires Suspended LED Fixture (Series EP14)
GE Lighting Solutions Installation Guide Lumination TM LED Luminaires Suspended LED Fixture (Series EP14) Features Long life (50,000 hour rated life) 5 year warranty IP30 Dry location rated BEFORE YOU
More informationOptimax Pro Retrofit Instructions
Copyright 2011 by ALL rights reserved. Information in this document is subject to change without notice. Companies, names and data used in examples herein are fictitious unless otherwise noted. No part
More informationCable Cubby 500 and 700 Installation Guide
e NT: R.com for thtion O P IM tron talla w.ex uide, ins ations. o ww Go t te user g specific nd ple com ctions, a u instr 500 and 700 Installation Guide This guide provides instructions for an experienced
More informationINSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight
SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation by a qualified electrician in accordance
More informationLUNERA T8 LED RETROFIT KITS 1/2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps
Gen 1 Installation Guide LUNERA T8 LED RETROFIT KITS 1/2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps Type C - External Driver Installation Description The LUNERA T8 LED RETROFIT KITS
More informationIMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité
MUV-401H MultiVoltage Germicidal Air Purifier Installation & Maintenance Instructions UNPACKING THE UNIT Each MUV-401H germicidal air purifier is shipped with the germicidal lamp placed in a lamp box.
More informationGETTING STARTED WITH IN-WALL DIMMER SWITCH
GETTING STARTED WITH IN-WALL DIMMER SWITCH This document is the property of Webee L.L.C. The data contained here, in whole or in part, may not be duplicated, used or disclosed outside the recipient for
More informationInstallation Guide for EcoBrite EndLite LED Light Fixtures
Installation Guide for EcoBrite EndLite LED Light Fixtures BEFORE YOU BEGIN INSTALLATION Read these instructions carefully. Failure to follow these instructions will invalidate the warranty on this product.
More informationOSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:
OSQ Series LED Area Light Direct Pole Mount IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY
More informationSpun Bay Installation Standard Version (non dimmable), Hook Mount
Spun Bay Installation Standard Version (non dimmable), Hook Mount WARNING: Make sure that all power is turned off while installing fixture. Do not turn power on until fixture is completely installed. Turn
More informationSTOP BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY
STOP BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY WARNING Risk of fire or electrical shock. LED retrofit installations require knowledge of luminaire electrical systems. If not qualified,
More informationUNPACKING THE UNIT. Alcohol cleaning pad
MUV-403H MultiVoltage Oxidizing UVC System Installation & Maintenance Instructions UNPACKING THE UNIT Each unit is shipped with the 5 lamp installed and the germicidal lamp placed in a box with protective
More informationInstallation Guide. WARNINGS Read all instructions and warnings before attempting installation
Installation Guide WARNINGS Read all instructions and warnings before attempting installation ALWAYS MAKE ABSOLUTELY SURE THE POWER IS OFF WHEN PERFORMING THE FIXTURE MODIFICATION. DURING INSTALLATION,
More informationHorticulture Batten LED Luminaire
GE Lighting Installation Guide Horticulture Batten LED Luminaire LED Lighting System BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSEMENT RISK OF ELECTRIC SHOCK Turn
More informationwww.greenelectricalsupply.com 1x4 2x2 & 2x4 Read all instructions and warnings before attempting installation. RISK OF FIRE OR ELECTRIC SHOCK. LED RETROFIT INSTALLATION REQUIRES KNOWLEDGE OF LUMINAIRES
More informationREAD AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.
Installation Instructions 2RTLEDR/2RTLEDRT Relight Assembly READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION. IMPORTANT SAFETY INSTRUCTIONS WARNING:
More informationULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS
Ultra Performance LED Tube Installation Instructions Page 1 of 7 ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS These instructions do not purport to cover all details or variations in components
More informationINSTALLATION INSTRUCTION Bollard Light 12V
Bollard Light 12V 6611/6621/6631/6641/6651 SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation
More informationM9109-GGx-5 Series Proportional Electric Non-spring Return Actuators
34-636- 1360, Rev. C Installation Instructions M9109-GGx-5 Issue Date March 2016 M9109-GGx-5 Series Proportional Electric Non-spring Return Actuators Installation IMPORTANT: Use this M9109-GGx-5 Series
More informationInstallation Instructions
Installation Instructions FHEZ10A24 FHEZ17A48 Page 1 of 7 IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 1. Do not mount near gas or electric heaters. 2. Do not attempt to service the battery.
More informationAcme Conduit Entry. String Combiner/Pass-Through. FOR PHOTOVOLTAIC INSTALLATION Installation Manual
Acme Conduit Entry String Combiner/Pass-Through FOR PHOTOVOLTAIC INSTALLATION Installation Manual Table of Contents Important Safety Instructions -----------------------------------------------------------------------------------------------------------
More informationREAD AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.
Installation Instructions RT8RT/RT5RT Relight Assembly READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION. IMPORTANT SAFETY INSTRUCTIONS WARNING: FAILURE
More informationLAL SERIES LED LUMINAIRE
INSTALLATION, OPERATION & MAINTENANCE DATA SHEET LAL SERIES LED LUMINAIRE CAUTION: LAL SERIES LED LUMINAIRE Before installing, make sure you are compliant with area classifications, failure to do so may
More informationLED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)
LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series) PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION SAFETY
More informationInstallation Instructions: External-Driver SEP T8 LED Tube Lamp
Installation Instructions: External-Driver SEP T8 LED Tube Lamp Installation Notes & Precautions: External-Driver SEP T8 LED Tube Lamp Read all precautions, warnings, instructions contained in this document.
More information100A 225A 400A PATENT PENDING
HomeRun Combiner Boxes Installation and Operation Manual 100A 225A 400A PATENT PENDING TABLE OF CONTENTS 1.0 Overview 2.0 Introduction 3.0 Important Safety Instructions 4.0 Disconnecting Combiner Box Electrical
More informationINSTALLATION INSTRUCTIONS
LED LIGHT ENGINE APPLICATION PROGRAM INSTALLATION INSTRUCTIONS LED Light Engine Kit Model: 9 Round Engine 120V: TRIAC DIMMING TKT120025RDxx-01 TKT120025RDxx-11 TKT120021RDxx-01 TKT120021RDxx-11 TKT120025RDxx-02
More informationLED SEMI-FLUSHMOUNT CEILING FIXTURE
ITEM #0760102 LED SEMI-FLUSHMOUNT EILING FIXTURE MODEL #SFL11BNK Français p. 9 Español p. 17 TTH YOUR REEIPT HERE Serial Number Purchase Date E465631 Questions, problems, missing parts? Before returning
More informationIMPORTANT: SAFETY INSTRUCTIONS
MUV-401H GERMICIDAL AIR PURIFIER Installation & Maintenance Instructions UNPACKING THE UNIT Each MUV-401H germicidal air purifier is shipped with the germicidal lamp placed in a lamp box. Carefully remove
More informationCSR COMPACT FUSED INTERLOCKED ARKTITE RECEPTACLE - 30 & 60 AMP Installation & Maintenance Information IF 1440
CSR COMPACT FUSED INTERLOCKED ARKTITE RECEPTACLE - 30 & 60 AMP Installation & Maintenance Information IF 1440 APPLICATION SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE CSR compact fused interlocked ARKTITE
More informationStrip Fixture URS Light Bar Retrofit Installation Instructions Revised:
Strip Fixture URS Light Bar Retrofit Installation Instructions Revised: 20180126 These instructions do not purport to cover all details or variations in components nor to provide for every possible contingency
More informationUniversal Retrofit System Installation Instructions Revised:
Universal Retrofit System Installation Instructions Revised: 20150624 These instructions do not purport to cover all details or variations in components nor to provide for every possible contingency to
More informationTM-11x1 Series Room Temperature Module
24-10225- 4, Rev. C TM-11x1 Series Installation Instructions Part No. 24-10225-4, Rev. C Issued March 16 Applications The TM-11x1 Series of s are designed for use with the TC-9102 Direct Digital Control
More informationInstallation Instructions BLTR and 2BLTR Relight Assembly
UT4540 Rev. B Installation Instructions BLTR and 2BLTR Relight Assembly This Relight assembly was engineered to upgrade most recessed fixtures mounted in T-grid ceiling installations, including most parabolic
More informationSystem 350 S350C Temperature Slave Stage Module
FANs 930, 930.5, 125, 121 Product/Technical Bulletin Issue Date April 8, 2014 System 350 Temperature Slave Stage Module The Temperature Slave Stage Module is used in conjunction with the A350 Temperature
More informationWARNING / AVERTISSEMENT
TM Arize LED Lighting System Lynk & Life Installation Guide BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING / AVERTISSEMENT RISK OF ELECTRIC SHOCK RISQUES DE DÉCHARGES ÉLECTRIQUES
More informationRAPID SHUTDOWN COMBINER
RAPID SHUTDOWN COMBINER Installation and Operation Guide Revision B 2017, Yaskawa Solectria Solar IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS 1. General Safety Information This manual contains
More informationOWNER S MANUAL OM F
OWNER S MANUAL OM-2606 96 030F May 2004 Cool Runner 3X. Specifications Recirculating Coolant System For Water-Cooled GTAW Torches And GMAW Guns Use With Guns/Torches Rated Up To 600 Amperes 3 gal (.4 L)
More informationM9109 Series Electric Non-spring Return Actuators
34-636- 1190, Rev. D Installation Instructions M9109 Issue Date 03/1/16 M9109 Series Electric Non-spring Return Actuators Installation IMPORTANT: Use this M9109 Series actuator only to control equipment
More informationIMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité
MUV7-100DR MultiVoltage UVC System Installation & Maintenance Instructions UNPACKING THE UNIT Each unit is shipped with the germicidal lamps placed in a box with protective packaging. When handling lamps
More informationINSTALLATION INSTRUCTIONS
6400 Vehicle Dock INSTALLATION INSTRUCTIONS " " " " " " " " " " " " " " " " " " " " " " " " " " " " PN: 962-020-006 Revision B August 1998 " NOTICE The information contained herein is proprietary and is
More informationVR44-MU-xxx-8yy-xxxxA
44 UNIVERSAL INPUT LINEAR LED RETROFIT KITS Suitable for 2 x 4 luminaires Suitable for use in retrofit rebate programs Kitted for ease of Installation with provided harness Universal Voltage with 0-0V
More informationLED Garage Light INSTALLATION INSTRUCTIONS. *Model number noted on carton label
LED Garage Light *Model number noted on carton label INSTALLATION INSTRUCTIONS Model Number / Número de Modelo / Numéro des modèle SGLL 24 PIR (24 LED Garage Light) Actual Dimensions 10 W x 3-1/2 H x 24-1/2
More information- Wiring Brochure tekmarnet 4 Thermostat 545
- Wiring Brochure tekmarnet 4 545 W 545 12/08 1 Information Brochure hoose controls to match application Application Brochure Design your mechanical applications 2 3 Layout Brochure ough-in 4 Wiring Brochure
More informationCSD Series Current Devices Split Core
CSD Series Current Devices Split Core Installation Instructions CSD-CF0A0-1 CSD-CF0J0-1 CSD-CA1G0-1 Part. 24-10345-34, Rev. D Issued March 31, 2014 Supersedes April 5, 2013 Applications The Current Switch
More informationINSTALLATION INSTRUCTION Oculux 3.5" Architectural Downlight R3CRN-11, R3CSN-11
. INSTALLATION INSTRUCTION SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation by a qualified
More informationINSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.
103158 March 9, 2011 FOR INDOOR USE ONLY Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045 (830)629-2900 / 1-800-729-3839 / Fax (830)620-6711 E-MAIL: detex@detex.com INTERNET: www.detex.com
More informationFan Relay Board (FRBii) Assembly
Fan Relay Board (FRBii) Assembly Installation, Operation, and Maintenance Instructions PK-FCU030-0, PK-FCU050-0 Part No. 24-10143-1221, Rev. A Issued February 2017 Application Refer to the QuickLIT website
More informationREAD AND SAVE THE INSTRUCTIONS
TONADO Under Cabinet ange Hood ON S MANUA Model No: Tornado 30, 36 AD AND SAV TH INSTUCTIONS! For domestic use only! Dear Customer, Thank you for your purchase from KitchenHoods.ca. If you follow the recommendations
More informationM9109-GGx-4 Series Proportional Electric Non-Spring Return Actuators
34-636- 1484, Rev. B Installation Instructions M9109-GGx-4 Issue Date March 2016 M9109-GGx-4 Series Proportional Electric Non-Spring Return Actuators Installation IMPORTANT: The M9109-GGx-4 Series Electric
More informationM9106-GGx-4 Series Proportional Electric Non-Spring Return Actuators
M9106-GGx-4 Series Proportional Electric Non-Spring Return Actuators 34-636- 1468, Rev. B Installation Instructions M9106-GGx-4 Issue Date March 2016 Installation IMPORTANT: The M9106-GGx-4 Electric Actuator
More informationUB-2 2 Universal Button
UB-2 2 Universal Button UB-2/LTUL Universal Button with Latching Timer ADA Compliant For UB-2/LTUL the enclosed timer is to be used and installed per the enclosed LT-1UL installation sheet. For access
More informationASTAT XB USER MANUAL. 1 Caution Statements
ASTAT XB USER MANUAL 1 Caution Statements Caution Statements cannot cover every potential cause of equipment damage but can highlight common causes of damage. It is the installer's responsibility to read
More informationAsymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.
support@i2systems.com www.i2systems.com Electrical Specifications PARAMETER Input Power VALUE 8 Watts* / Ft Input Voltage 120-277V AC, 50/60 Hz Max. Fixture Run Length LED Color (CCT) 8 Watts: 120VAC:
More informationAssembly Instructions Retrofitting
Assembly Instructions Retrofitting These instructions are for replacing existing lighting fixtures or systems with our new, higher efficiency TLS, drivers and controls. www.tls-lumisign.com 514-858-6556
More informationInstruction Sheet ERK-XXXXKD SERIES KNOCKDOWN STANDALONE RACK
Instruction Sheet ERK-XXXXKD SERIES KNOCKDOWN STANDALONE RACK C UL R US LISTED THANK YOU Thank you for purchasing the ERK-XXXXKD Series Knockdown Standalone Rack. Please read these instructions thoroughly
More informationInstallation Instructions
at :: rangehoods. com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Installation Instructions ZV950 36" Stainless Steel Vent Hood Monogram. We bring good things to life. GE Monogram
More informationSentinel Field Satellite Controller
WARNING HIGH VOLTAGE 115V M AP Sentinel Field Satellite Controller Installation Instructions Important: For your protection and the safety of the product user, please comply with all Caution and Warning
More informationLUNERA T8 LED RETROFIT KITS 2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps
Gen 1 Installation Guide LUNERA T8 LED RETROFIT KITS 2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps Type C - External Driver Installation Description The LUNERA T8 LED RETROFIT KITS consist
More informationM9300 Series Potentiometer Kits
M9300 Series Potentiometer Kits Installation Instructions M9300-140, M9300-1K, M9300-2K, M9300-10K 34-636- 2480, Rev. C (barcode for factory use only) Part No. 34-636-2480, Rev. C Issued June 2017 Application
More informationM9106-AGx-2N0x Series Electric Non-Spring Return Actuators
34-636- 1077, Rev. C M9106-AGx-2N0x Series Electric Non-Spring Return Actuators Installation Instructions M9106AGx-2N0x Issue Date March 2016 Installation IMPORTANT: Use this M9106-AGx-2N0x Series Actuator
More informationINSTALLATION GUIDE FOR VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM
For Service Technicians only INSTALLATION GUIDE FOR VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM This manual describes works to be performed with the unit's case open. Leave all these works to a qualified
More informationVA-4233-AGx Series Electric Valve Actuators
Installation Instructions VA-4233 No. 1 Issue Date June 30, 2014 VA-4233-AGx Series Electric Valve Actuators Installation Refer to Figures 2 through 4 for proper actuator orientation before attempting
More informationInstallation Instructions
Installation Instructions If you have questions, call 800.GE.CARES or visit our website at: www.monogram.com ZV950 36" Stainless Steel Vent Hood Safety Information BEFORE YOU BEGIN Read these instructions
More informationSAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS
Champ Fluorescent Luminaires DMVFB Auxiliary Series - 52, 64, & 84 Watt Installation & Maintenance Information SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IF 1713 IMPORTANT SAFEGUARDS READ AND FOLLOW
More informationInstallation Instructions: Memory-Dimmable SEP T8 Tube Lamps
Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps Installation Notes & Precautions: Memory-Dimmable SEP T8 LED Tube Lamp Read all precautions, warnings, instructions contained in this document.
More information