1 Starting System DS-102 Series 200 Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F post@elmatik.no

2 CONTENT 1. INTRODUCTION 3 2. TECHNICAL SPECIFICATIONS 4 3. OPERATIONAL DESCRIPTION General 3.2 Manual Starting Procedure 3.3 Starting failure Alarms and Safety actions 3.5 Automatic Start / Stop 3.6 Normal Stop 4. TECHNICAL DESCRIPTION The TACHO Card 4.2 The Start / Stop Card The Alarm / Shut-down Card GENERAL ARRANGEMENT CUT-OUTS 20 2

3 1. INTRODUCTION Diesel starter DS-102 Series 200 is a control system, designed to enable manual and automatic control and supervision of Diesel engines. The system has the following functions: - Manual START and STOP. - Automatic START and STOP. - 4 separate channels for initiating Automatic shut-down. - Detection and Indication of RPM. - Choice of 1, 2, 3 starting attempts. - Adjustable Starting - time. - Adjustable Stopping - time. - Adjustable Blocking time for lubricating oil pressure - Outputs (potential free change over contacts) for: 1. Alarm for Shut-down. 2. Running indication. 3. Alarm Low voltage. 4. Alarm blocking of lubricating oil pressure. - Extra: 6-Channel alarm system. (Optional) 3

4 2. TECHNICAL SPECIFICATIONS - System arrangement: All circuitry is built on plug-in type printed cards and mounted in a self contained unit which is taking care of all necessary operational functions. MOS integrated circuits are used extensively to ensure a high degree of reliability. - Permissible Ambient temperature: 0 o 60 o C. - Duration Starting signal: sec. (adjustable) - Number of Starting attempts: 1, 2, 3, (Selective *) - Duration Stop signal: sec. (adjustable) - Duration Alarm blocking: 8 45 sec. (adjustable) - Tachometer type: Magnetic Transducer Type EMP 9 (others possible). - Tacho input frequency: pulses/sec. - Accuracy RPM indicator: +/- 2% FSD. - External RPM indicator: Moving coil meter 1 ma FSD. - Sensors for Auto Shut-down: Normally open contact. 4

5 TECHNICAL SPECIFICATIONS continued - External signal contacts: Change-over contacts for: - Alarm Auto Shut-down - Running Indication - Alarm Low voltage - Alarm blocking - Auto control - Max. Rating: 2Amp. - Power demand: Nominal voltage: 24 Vdc Limit values: Vdc Current consumption: 0.3 Amp 5

6 3. OPERATIONAL DESCRIPTION 3.1 General Viewed from left to right the Control Panel of DS-102 is divided into the following units: a) The Tacho Card (D-201-x) The card supervises starting procedures, RPM etc. of the Diesel set. It comprises indicating lights for obtained started speed (STARTED) and running speed (RUNNING). The card also supplied with three push-buttons used for reading and adjusting the three set points for STARTED, RUNNING, as well as OVER-SPEED. b) The Start / Stop Card (D-202-x) This card executes the various start and stop orders as they are initiated, either from the control unit itself, or from a remote control position. The card contains indicating lights for START and STOP showing the order which has been given. c) The Alarm / Shut-down Card (D-203-x) The card takes care of the safety requirement and will give alarm and automatic shu-down of the set for certain faults. The card has lamps for low lubricating oil pressure (LUB OIL PRESS. LOW), high cooling water temperature (COOL WATER TEMP. HIGH) as well as for high RPM (OVERSPEED). In addition to a spare alarm channel the card is also supplied with an indicating light, informing of whether the equipment is blocked for further startup procedures. d) The Meter unit This unit contains the RPM meter as well as the main control push-buttons for START, AUTO and STOP. 6

7 3.2 Manual Starting Procedure Manual start of the diesel set is initiated by pressing the START button. The indicator for START will light, and the starting solenoid (or the starting motor) will be energized. The indicator for STOP will be turned off. When the set reaches ignition speed (usually set to 20%) the indicating light for STARTED will be turned on. The starting solenoid (starting motor) is then de-energized. As the Diesel set approaches running speed the indicator light for RUNNING will become alight (usually set to 80%). Approximately 40 sec. after start, the indicating lamp RESTART BLOCKED will light up. At normal running conditions the following indicators are therefore turned ON: 3.3 Starting failure START STARTED RUNNING RESTART BLOCKED (after 40 sec.) One can pre-selected 1, 2, or 3 starting attempts. If a starting failure should take place, up to two extra starting attempts will be executed before the indicator lamp RESTART BLOCKED is turned on, indicating that the system will not perform any more starting attempts before the blocking is reset. RESTART BLOCKED is reset by pressing the STOP push-button. NOTE! During normal running, RESTART BLOCKED will be alight after 40 sec., and shall in this case of course not be reset by means of the STOP push-button. 7

8 3.4 Alarms and Safety actions The following system faults will initiate alarm, light up the corresponding lamp on the control panel and lead to automatic shut-down: - Low lubricating oil pressure (LUB OIL PRESS LOW) - High cooling water temperature (COOL WATER TEMP. HIGH) - High RPM (OVERSPEED) In each case the system must be reset by pressing the STOP pushbutton before a new starting attempt can be initiated. If the fault still remains, alarm and auto shut-down will again be initiated. 3.5 Automatic Start / Stop The system is set to remote control by pressing the AUTO push-button. The STOP and START indicating lamps on the Start /Stop card (D-202- x) indicate the operation order received from the remote control position. 3.6 Normal Stop Normal stop of the diesel set is achieved by pressing the STOP pushbutton, thus energizing the stop solenoid. During normal conditions only the STOP indicator lamp should be alight. 8

9 4. TECHNICAL DESCRIPTION 4.1 The Tacho Card (D-201-x) Fig. 2. D-201-x: Functions and external connections. 9

10 The Tacho generator is a pulse generating type, and the pulse rate is proportional to the engine speed. The Tacho generator is connected to pins 31 and 32 via terminals 38 and 39. the frequency to voltage will change the pulse signal to a DC voltage signal proportional to the engine speed. The DC voltage signal is fed to three different comparators units for the STARTED, RUNNING and OVERSPEED functions. The STARTED output signal is fed to card D-202-x via pin 8. the output signal for RUNNING operates relay change-over contacts connected to terminal 24,25 and 26 on Terminal Board L2 (C 510A). The output signal from the comparator for OVERSPEED is fed via terminal 7 to the alarm and auto shut-down circuits on card D- 203-x. The set points for all comparators can be adjusted by means of screwdriver controls (15 turn potis) at the front of the card. The procedure is as follows: Press the control push-button for the desired function, Adjust the corresponding screwdriver control until RPM- Meter indicates the desired value. The equipment is normaly supplied from the manufacturer with the following preset values: STARTED 20% RUNNING 80% OVERSPEED 115% 10

11 RPM Adjust Fig. 3. D-201-x: Tacho Card The frequency to voltage converter is also feeding a signal to a voltage to current converter, driving the RPM indicator M1 as well as a possible external indicator. The frequency to voltage converter is adjusted by the manufacturer and should not be re-adjusted unless absolutely needed to do so. The Tacho-card is also supervising the supply voltage. A relay contact will operate when the voltage drops below 18 volts. The contact is connected to terminals 21, 22 and 23 on Terminal Board L2 (C 510A) via pins 4, 5 and 6. 11

12 4.2 The Start / Stop Card (D-202-x) Fig. 4. D-202-x Functions and external connections. 12

13 Starting and stopping on the Diesel set is normally performed by means of the START and STOP push-buttons on the front panel. Starting and stopping can also be automatic, e.g. from an isolating relay operating by mains failure or similar. When automatic operation is to take place the AUTO push-button on the front panel must be pressed. The START, AUTO and STOP push-buttons are interlocked such that only one can be pressed at a time. Orders for START or STOP are executed by giving the pins 16 respectively 15 zero potential. When the AUTO push-button is pressed, the Diesel set will start when 24V dc is supplied to pins 6 and 7. The Diesel set will stop when the voltage is removed. The card may also be equipped with a latching relay to accept impulse Start and Stop (see drawing). Start time Adjust. Stop time Adjust. Fig. 5. D-202-x: The Start / Stop Card. 13

14 A starting order will set the memory. The START indicator will light up, and start order will be fed via RESTART COUNTER CONTROL to the START STOP CONTROL, to the START EXITATION and the START RELAY which operates the Diesel set s starting system. The Diesel starter can be arranged to give 1, 2 or 3 starting attempts. This is made by the maker as specified. The starting periods are usually adjusted between 10 and 15 seconds. If the Tacho Card (D-201-x) senses that ignition speed ( STARTED) has been reached the starting-relay will be de exitated. Fig. 5. shows card D-202-x and in particular the adjusting potentiometers for Starting and Stopping Time. The time duration for each starting attempt can be adjusted between 10 and 45 seconds. The potentiometers have been set by the maker, and re adjustments are normally not necessary. If the Diesel set does not start, the system will perform the predetermined number of starting attempts. If the set still has not started, the RESTART COUNTER CONTROL will block any further starting attempts. The indicator lamp RESTART BLOCKED will be turned on. The circuits for restart blocking will be activated approximately 40 seconds after a normal start of the Diesel set. The indicator lamp RESTART BLOCKED will therefore be alight after a normal start has taken place. This has been done as a safety measure if irregularities should occur in the engine speed measuring system. A stop order will set the memory in opposite direction. The START lamp will go out and the STOP lamplight up. The STOP relay will be energizes via the START STOP CONTROL and the STOP EXITATION unit, thus activating the Diesel set s stop solenoid. 14

15 The stopping time can be adjusted on a separate potentiometer (see fig. 5.). The stopping time is the time when the STOP relay remains energized after the RPM of the Diesel set has fallen below the STARTED level. The maker has usually set this time to about 15 seconds. In order to avoid overheating of the stop solenoid the total energizing time is in any case limited to max. 55 seconds. Orders for automatic Shutdown will be generated in the Alarm-/Shut-down Card for certain faults. These signals are fed from pin 26 on the Alarm-/Shut-down card to pin 20 on the Start / Stop Card. Such signals will operate the START STOP CONTROL and the STOP EXITATION unit and stop the Diesel set in the same way as described above. New start-up attempts are blocked until the system has been reset, by operating the STOP push-button. 15

16 4.3 The Alarm-/Shut-down Card (D-203-x) Fig. 6. D-203-x: Functions and external connections. 16

17 The card comprises the following 4 alarm channels: - Lubrication Oil Pressure, Low: The pressure transducer is connected to terminals 15 and 16 on the Terminal Board (D 510A) Strip L2. - Cooling Water Temperature, High: The temperature transducer is connected to terminals 19 and 20 on Terminal Board (D 510A) Strip L2. - OVERSPEED: The signal is obtained from pin 7 on the Tacho Card (D-201-x) and fed to pin 12 on the Alarm-/Shut-down Card (D-203-x). - SPARE: The alarm initiator might be connected to terminals 17 and 18 on Terminal Board (D 510A) Strip L2. If one of the above alarms are initiated, a corresponding alarm light on the front panel will be turned on. At the same time a common Shutdown channel will be activated. The signal is fed from pin 26 to pin 20 on the Start / Stop card. A common external alarm circuit is activated by means of a relay contact connected to terminals 9, 10 and 11 on Terminal Board (D 510A) Strip L2 (corresponding to pins 18, 19 and 20 on the card.). When an alarm and shut-down has taken place, the system must be reset before the Diesel set again can be started. This is obtained by pressing the STOP push-button. The card is supplied with a blocking relay which can be used for suppressing alarms etc. in external circuits. The change-over contact is connected to terminals 12, 13 and 14 on Terminal Board (C 510A) Strip L2, (corresponding to pins 14, 15 and 16 on the card.). 17

18 The Alarm-/Shut-down function for Lubrication Oil Pressure, Low is blocked internally when the Diesel set is stopped. The blocking is automatically cancelled about 8 seconds after the starting relay is deenergized after start and the memory has stored an order for start. Lub. Oil Block time Adjust Fig. 7. D-203-x: Alarm-/Shut-down Card 18

19 GENERAL ARRANGEMENT 19

20 CUT OUTS Height: Width: 177 mm 278 mm Settings: Serial No.: 979 RPM : 1800 Z : % : 3780 Hz Start : Min. Stop :_Min. Block : Min. Started:_300 Run :_1000 Overspeed : 2070 Spare parts: Order no.: Description: D-201-x Tacho Card D-202-x Start / Stop Card D-203-x Alarm-/ Shut-down Card L D-203-xL Alarm-/ Shut-down Card w/latching relay D-204-x Main back plane (Mother board) D-205 Control panel w/meter gauge and buttons D-607-x Alarm Card (Optional) DA-605-x Alarm back plane (Optional) Extension Card D-607 Only (To take measurements) Cable D-Sub 15 DS (Optional) 1.5m Cable D-Sub 37 DS Main flat cable 1.5m Cable IDC-14 DS cm C 510A Terminal Board Strip L C 610A Terminal Board Strip L3 (Optional) Push-buttons (Used in the control panel) RPM Panel meter (Used in the control panel) Items marked Optional are items used with DS systems equipped with the extra Alarm section. -ooo- 20

Flight Systems. Replacement for KASSEC DESCRIPTION

Flight Systems.   Replacement for KASSEC DESCRIPTION DESCRIPTION The is a universal generator controller that will start, stop, and provide engine protection for most generators. Universal replacement for both the 90353 and 90354 KASSEC Compatible with most

More information

GENSET CONTROL MODULE A121H / A241H. User selectable time delays for engine start and engine stop (cool down).

GENSET CONTROL MODULE A121H / A241H. User selectable time delays for engine start and engine stop (cool down). Technical Data Sheet GENSET CONTROL MODULE A121H / A241H Features: Models for both 12V and 24V systems. One model for both spark ignition and diesel engines. 4-alarm light outputs with lamp-test provisions.

More information

GENSET CONTROL MODULE LEVEL 1 A121CM / A241CM. Special logic to re-establish cranking following a false start.

GENSET CONTROL MODULE LEVEL 1 A121CM / A241CM. Special logic to re-establish cranking following a false start. Technical Data Sheet GENSET CONTROL MODULE LEVEL 1 A121CM / A241CM Features: Models for both 12V and 24V systems. One model for both spark ignition and diesel engines. 5-alarm light outputs with lamp-test

More information

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM DSE 520 ISSUE 4 4/4/02 MR 1 TABLE OF CONTENTS Section Page INTRODUCTION... 4 CLARIFICATION OF NOTATION USED WITHIN THIS PUBLICATION.... 4 1. OPERATION...

More information

GENSET CONTROL MODULE A121A / A241A

GENSET CONTROL MODULE A121A / A241A Technical Data Sheet GENSET CONTROL MODULE A121A / A241A Features: Models for both 12V and 24V systems. One model for both spark ignition and diesel engines. 4-alarm light outputs with lamp-test provisions.

More information

ENGEN -100/ENGEN -200 ENGINE GENERATOR CONTROLLER

ENGEN -100/ENGEN -200 ENGINE GENERATOR CONTROLLER ENGEN -100/ENGEN -200 ENGINE GENERATOR CONTROLLER The engine/generator controller is an integrated genset controller contained in a single, easy to install package. The controller contains a microprocessor-based

More information

PSM72H Push-Button Start Module

PSM72H Push-Button Start Module Capricorn Controls DA02PSM72H1-2 Data & Application Note Page 1 of 6 PSM72H Push-Button Start Module Genset Controls - Timers/Monitors/Trips - Battery Charging Spares & Accessories - Custom Products Ultra

More information

EPM72 Engine Protection Module

EPM72 Engine Protection Module Capricorn Controls DA01EPM1-1 Data & Application Note Page 1 of 8 EPM2 Engine Protection Module Genset Controls - Timers - Monitors - Trips - Battery Charging - Spares & Accessories - Custom Products All

More information

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version MD10 Engine Controller Installation and User Manual for the MD10 Engine Controller. Full Version File: MartinMD10rev1.4.doc May 16, 2002 2 READ MANUAL BEFORE INSTALLING UNIT Receipt of shipment and warranty

More information

8803214-8803999 DIODE BOARD The diode board is located inside the lower control box. D15 D8 D7 D14 D5 D13 ART_2181 J1 14 8 D9 D10 7 1 R2 R1 R3 R4 TB1 8601 D11 D3 D12 D4 D1 D2 J1 Plug Pin Identification

More information

DIODE BOARD The diode board is located inside the lower control box. D15 D8 D7 D14 D5 D13 ART_2181 J1 14 8 D9 D10 7 1 R2 R1 R3 R4 TB1 8601 D11 D3 D12 D4 D1 D2 J1 Plug Pin Identification PIN # WIRE # SIGNAL

More information

AUTOMATIC STAND-BY AND PEAK-LOAD CONTROL

AUTOMATIC STAND-BY AND PEAK-LOAD CONTROL KUHSE Operating Instructions Control Unit for Gen. Power Sets AUTOMATIC STAND-BY AND PEAK-LOAD CONTROL Type: KEA 071-SPL TA71SXXE.01 July 1996 (REPLACES 1994 EDITION) GENERAL DESCRIPTION AND APPLICATION

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC DEEP SEA ELECTRONICS PLC 703 AUTOMATIC START MODULE OPERATING INSTRUCTIONS Author:- John Ruddock 703 Operating Instructions Issue Beta1 25/08/2003 2:45 PM JR - 1 - >

More information

J1 Plug Pin Identification

J1 Plug Pin Identification D D8 D D D D ART_8 J 8 D D0 R R R R TB 80 D D D D D D J Plug Pin Identification PIN # WIRE # SIGNAL FUNCTION 0 INPUT Drive Reverse INPUT Drive Forward OUTPUT Brake, Decel Valve signal 8 INPUT Steer Left

More information

HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic

HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic CONTENT 1 SUMMARY... 4 2 FEATURES... 4 3 SPECIFICATION... 4 4 DISPLAY SYMBOL AND OPERATION... 5 5 ALARM... 7 6 PARAMETERS TABLE (ONLY

More information

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY Sheet 1 of 5 Order Number Serial Number PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY Issue Date Level B 27/05/1999 Initial issue. Summary of changes Due to RMS continuous product improvement policy

More information

ELECTRIC SCHEMATICS LS1 LS2. "1532ES / 1932ES" Service & Parts Manual - ANSI Specifications March 2008 Page 5-9 ART_2236 ART_2243

ELECTRIC SCHEMATICS LS1 LS2. 1532ES / 1932ES Service & Parts Manual - ANSI Specifications March 2008 Page 5-9 ART_2236 ART_2243 ELECTRIC SCHEMATICS NOTES: (Unless otherwise specified). Switch S BASE/PLATFORM makes contact from the CENTER to the LEFT position when placed in BASE.. Switch S UP/DOWN makes contact from the CENTER to

More information

ES52 Auto Start Engine Controller Installation and User Manual for the ES52 Auto Start Engine Controller.

ES52 Auto Start Engine Controller Installation and User Manual for the ES52 Auto Start Engine Controller. ES52 Auto Start Engine Controller Installation and User Manual for the ES52 Auto Start Engine Controller. Full Version File: ES52rev2.63.doc October 24, 2006 2 Thank You For Purchasing This DynaGen Product

More information

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS 702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS > TABLE OF CONTENTS 1 DESCRIPTION OF OPERATION... 4 1.1 MANUAL MODE OPERATION... 4 1.2 AUTOMATIC MODE OF OPERATION...

More information

1. AC VOLTS: Displays generator output in voltage. 2. AC FREQUENCY: Displays the speed of the generator set in Hertz.

1. AC VOLTS: Displays generator output in voltage. 2. AC FREQUENCY: Displays the speed of the generator set in Hertz. 1. AC VOLTS: Displays generator output in voltage. 2. AC FREQUENCY: Displays the speed of the generator set in Hertz. 3. AMMETER/PERCENT OF LOAD: Displays the load on the generator in amps or in percentage.

More information

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE USER MANUAL IMI vibration switch INSTALLATION - OPERATION - MAINTENANCE Z0929039_A ISSUED 03/2017 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. contents Overview General

More information

GENSET CONTROL MODULE LEVEL 0 A120A. User selectable time delays for engine start and engine stop (cool down).

GENSET CONTROL MODULE LEVEL 0 A120A. User selectable time delays for engine start and engine stop (cool down). Technical Data Sheet GENSET CONTROL MODULE LEVEL 0 A120A Features: One model for both spark ignition and diesel engines. 4-alarm light outputs with automatic lamp-test provision. Overspeed adjustment not

More information

GCU-10. Automatic Engine Control Unit Operators Manual

GCU-10. Automatic Engine Control Unit Operators Manual GCU-10 Automatic Engine Control Unit Operators Manual KUTAI ELECTRONICS INDUSTRY CO., LTD. TEL : +886-7-8121771 FAX : +886-7-8121775 Website : www.kutai.com.tw Headquarters : No.3, Lane 201, Chien Fu St.,

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS PLC DSE704 AUTOSTART CONTROL MODULE OPERATING MANUAL 057-042 704 Operating Instructions Issue 2.1 18/06/2007 11:27:00 JR - 1 - Deep Sea Electronics Plc

More information

REVISED ATM72 Auto Transfer Module

REVISED ATM72 Auto Transfer Module Capricorn Controls DA01ATM1-1 Data & Application Note Page 1 of 8 REVISED - - - ATM72 Auto Transfer Module Genset Controls - Timers - Monitors - Trips - Battery Charging - Spares & Accessories - Custom

More information

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com

More information

Application Engineering

Application Engineering Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor

More information

MAGNETIC MOTOR STARTERS

MAGNETIC MOTOR STARTERS Chapter 6 MAGNETIC MOTOR STARTERS 1 The basic use for the magnetic contactor is for switching power in resistance heating elements, lighting, magnetic brakes, or heavy industrial solenoids. Contactors

More information

HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic

HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic Smartgen Electronic Equipment Co., Ltd No.28 Jinsuo Road Zhengzhou Henan Province P.R.China Tel: 0086-371-67988888/67981888 0086-371-67991553/67992951/67992952

More information

J1 Plug Pin Identification

J1 Plug Pin Identification D5 D D D D5 D ART_ J D D0 R R R R TB 0 D D D D D D J Plug Pin Identification PIN # WIRE # SIGNAL FUNCTION 0 INPUT Drive Reverse INPUT Drive Forward OUTPUT Brake, Decel Valve signal INPUT Steer Left 5 OUTPUT

More information

J1 Plug Pin Identification

J1 Plug Pin Identification D5 D8 D7 D4 D5 D ART_8 J 4 8 D D0 7 R R R R4 TB 80 D D D D4 D D J Plug Pin Identification PIN # WIRE # SIGNAL FUNCTION 0 INPUT Drive Reverse INPUT Drive Forward OUTPUT Brake, Decel Valve signal 4 8 INPUT

More information

DKG-114 MANUAL AND REMOTE START UNIT

DKG-114 MANUAL AND REMOTE START UNIT DKG-114 MANUAL AND REMOTE START UNIT FEATURES Both manual and remote controlled engine starting and stopping, Automatic shutdown on fault condition, Optional cooldown cycle on remote start operation, Optional

More information

MODEL CMS INSTALLATION INSTRUCTIONS A. INTRODUCTION 1. USAGE 2 2. HOW IT OPERATES 2 B. SPECIFICATIONS 1. ELECTRICAL 3 2.

MODEL CMS INSTALLATION INSTRUCTIONS A. INTRODUCTION 1. USAGE 2 2. HOW IT OPERATES 2 B. SPECIFICATIONS 1. ELECTRICAL 3 2. CONVEYOR COMPONENTS COMPANY 130 Seltzer Road, PO Box 167 Croswell, MI 48422 USA PHONE: (810) 679-4211 TOLL FREE (800) 233-3233 FAX: (810) 679-4510 Email: info@conveyorcomponents.com http://www.conveyorcomponents.com

More information

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL SECTION 23 04 10 ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

GPU Equipment Operating Instructions Table of Contents

GPU Equipment Operating Instructions Table of Contents GPU Equipment Operating Instructions Table of Briggs & Stratton Model: 30439 Davco Model: GP28R under construction Foxtronics Model: PR-2000-T7S GUINAULT MODEL: GA90V133 HOBART MODEL: JET EX-2, EX-3, EX-4,

More information

Application Engineering

Application Engineering Application Engineering March 2011 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital compressor or the

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE4120 AUTO MAINS FAILURE MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel:

More information

XCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY

XCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY Reso-not TM Damping System XCITE Owner s Manual 1502C HYDRAULIC POWER SUPPLY Xcite Systems Corporation 675 Cincinnati RDS Batavia - 1 Pike Cincinnati, Ohio 45245 Tel: (239) 980-9093 Fax: (239) 985-0074

More information

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control SERVICE UNIT INFORMATION SUPPLEMENT HP21 Corp. 9426 L10 Litho U.S.A. All HP21-4 and -5 units (single and three phase) are equipped with a TSC6 two-speed control. The TSC6 (A14) two-speed control contains

More information

5001TCP SPEED CONTROLLER

5001TCP SPEED CONTROLLER INSTALLATION AND SETTING UP MANUAL 5001TCP SPEED CONTROLLER WARNING Disconnect all incoming power before working on this equipment. Follow power lockout procedures. Use extreme caution around electrical

More information

R & D SPECIALTIES ROTROL I USER'S MANUAL

R & D SPECIALTIES ROTROL I USER'S MANUAL R & D SPECIALTIES ROTROL I USER'S MANUAL TABLE OF CONTENTS INTRODUCTION...2 SPECIFICATIONS...2 CONTROLS AND INDICATORS...3 TIME DELAYS...4 INSTALLATION...5 SYSTEM OPERATION...9 TROUBLESHOOTING...13 OPTIONAL

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS WARNING: WARNING: www.altronicinc.com DEVIATION DEVIATION FROM THESE FROM INSTRUCTIONS THESE INSTRUCTIONS MAY LEAD MAY TO LEAD IMPROPER TO IMPROPER OP- ERATION OF ENGINE THE MACHINE

More information

ELECTRICAL SYSTEM RP-7

ELECTRICAL SYSTEM RP-7 ELECTRICAL SYSTEM RP-7 This section of the manual does not include integral electrical components of the engine. Refer to section Engine RP-1 for details. This section of the manual is divided into three

More information

MODEL RMS INSTALLATION INSTRUCTIONS. CONTENTS Page A. Introduction 1. Usage 2 2. How it operates 2

MODEL RMS INSTALLATION INSTRUCTIONS. CONTENTS Page A. Introduction 1. Usage 2 2. How it operates 2 CONVEYOR COMPONENTS COMPANY Division of Material Control, Inc. 130 Seltzer Road, PO Box 167 Croswell, MI 48422 USA PHONE: (810) 679-4211 TOLL FREE (800) 233-3233 FAX: (810) 679-4510 Email: info@conveyorcomponents.com

More information

KD LV Motor Protection Relay

KD LV Motor Protection Relay 1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage

More information

ES52. Auto Start Engine Controller. Full Version. Installation and User Manual for the ES52 Auto Start Engine Controller.

ES52. Auto Start Engine Controller. Full Version. Installation and User Manual for the ES52 Auto Start Engine Controller. ES52 Auto Start Engine Controller Installation and User Manual for the ES52 Auto Start Engine Controller. Full Version File: MAN-0001 R4.0, ES52 User Manual.doc Date: August 2017 Thank You For Purchasing

More information

ICON 2 1. FEATURES AND CHARACTEIRICS

ICON 2 1. FEATURES AND CHARACTEIRICS ICON 2 1. FEATURES AND CHARACTEIRICS High end Micro-controller(DSP) technology Wide range of auxiliary supply: 7V to 45Vdc. Low power Consumption : 200 ma @ 12 V DC. Alphanumeric 16X4 or 16X2 LCD display

More information

A1P OPERATING MANUAL

A1P OPERATING MANUAL A1P OPERATING MANUAL TABLE OF CONTENTS Introduction... p. 2 Features... p. 2 Description... p. 3 Theory of Operation... p. 3 Installation... p. 4 Electrical Connections... p. 5 Options... p. 6 Warranty...

More information

TECHNICAL MANUAL AND ELECTRONICAL MODULE REGULATION VVVF-4 +

TECHNICAL MANUAL AND ELECTRONICAL MODULE REGULATION VVVF-4 + TECHNICAL MANUAL AND ELECTRONICAL MODULE REGULATION VVVF-4 + 8 CABIN DOORS DESCRIPTION OF SWITCHES The unit may be programmed using the DIL switches on the front of the unit. If any change is made to any

More information

Troubleshooting Guide

Troubleshooting Guide Troubleshooting Guide P/N 0153180 July 1999 P.O. Box 1160 St. Joseph, MO 64502-1160 1-800-255-0317 Fax: 816-360-9379 www.snorkelusa.com GENERAL INFORMATION This manual contains procedures for locating

More information

5001TCP SPEED CONTROLLER

5001TCP SPEED CONTROLLER VARIABLE SPEED DRIVE CONTROLLER INSTALLATION AND SETTING UP MANUAL 5001TCP SPEED CONTROLLER With PC101 Torque Limit Control WARNING Disconnect all incoming power before working on this equipment. Follow

More information

MAGNAMAX DVR DIGITAL VOLTAGE REGULATOR

MAGNAMAX DVR DIGITAL VOLTAGE REGULATOR MAGNAMAX DVR DIGITAL VOLTAGE REGULATOR TECHNICAL MANUAL MODEL DVR 2000 AND DVR 2000C FIGURE 1 - FRONT AND REAR VIEW OF VOLTAGE REGULATOR...4 SECTION 1- INTRODUCTION...5 GENERAL DESCRIPTION...5 SPECIFICATIONS...5

More information

Generator Start Control Module

Generator Start Control Module Generator Start Control Module Part# GSCM-mini-i ATKINSON ELECTRONICS, INC. 14 West Vine Street Murray, Utah 84107 Contact cbdsales@atkinsonel.com for the proper hookup diagram. Please include the generator

More information

Deep Sea Electronics Plc

Deep Sea Electronics Plc Deep Sea Electronics Plc 5120 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL Author: Anthony Manton Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH England Tel: +44 (0) 1723

More information

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION Medium Voltage Standby non-paralleling Control 1. GENERAL GUIDE FORM SPECIFICATION A. The requirements of the contract, Division 1, and part 16 apply to work in this section. 1.01 SECTIONS INCLUDE A. Medium

More information

ANALOG CONTROL PANEL

ANALOG CONTROL PANEL ANALOG CONTROL PANEL 1. AC VOLTS: Displays generator output in voltage. 2. AC FREQUENCY: Displays the speed of the generator set in Hertz. 3. Percent of Load: Displays percentage of load on the generator.

More information

5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL

5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL 5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL > Section DSE Model 5220 Automatic Mains Failure & Instrumentation System Operators Manual TABLE OF CONTENTS

More information

CENTROIDTM. AC Brushless Drive. Product Spec Sheet

CENTROIDTM. AC Brushless Drive. Product Spec Sheet 4 Axis, up to 2 KW motors Brake Output for each axis Overtemp and Overcurrent Protection All-software Configuration Self-cooled Fiber Optic Control CENTROIDTM AC Brushless Drive Product Spec Sheet AC Brushless

More information

Phenix Technologies Inc. 75 Speicher Drive Accident, Maryland 21520

Phenix Technologies Inc. 75 Speicher Drive Accident, Maryland 21520 USER S MANUAL PORTABLE HIGH CURRENT TEST SET MODEL NUMBER HC2 Version 4.0 Phenix Technologies Inc. 75 Speicher Drive Accident, Maryland 21520 Copyright Phenix Technologies, Inc. Rev 11/20/2014 nab TABLE

More information

ECU. Speed Switch Manual. Contents. ECU is a registered trademark of Engineering Concepts Unlimited Inc.

ECU. Speed Switch Manual. Contents. ECU is a registered trademark of Engineering Concepts Unlimited Inc. ECU Speed Switch Manual Contents ECU is a registered trademark of Engineering Concepts Unlimited Inc. Contents Unit review Magnetic pickup example AC input example Design Guide Troubleshooting guide 24

More information

MaxPak Plus Analog DC V S Drive

MaxPak Plus Analog DC V S Drive Three-Phase 3-600 HP non-regenerative and 5-150 HP regenerative drives Designed to accommodate a wide range of industrial requirements, the DC V S Drive has been widely applied worldwide. Selected ratings

More information

A6Z OPERATING MANUAL

A6Z OPERATING MANUAL A6Z OPERATING MANUAL TABLE OF CONTENTS Introduction... p. 2 Features... p. 2 Description... p. 3 Theory of Operation... p. 3 Installation... p. 4 Electrical Connections... p. 5 Options... p. 6 Warranty.p.

More information

Modulating Furnace Information. Warning on Meter Setting - Read First!

Modulating Furnace Information. Warning on Meter Setting - Read First! Modulating Furnace Information Pressure Transducer Pressure DC Volts 0.00" 0.25 0.20" 0.63 0.25" 0.72 0.30" 0.82 0.35" 0.91 0.40" 1.00 0.45" 1.09 0.50" 1.19 0.55" 1.28 0.60" 1.38 0.65" 1.47 0.70" 1.56

More information

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech The Axpert-CSS is a range of Combination Soft Starter panels offered by AMTECH DRIVES. We also offer the module unit as an individual product, named as Axpert-Opti torque Soft Starter. This is only the

More information

Generator Controller Manual

Generator Controller Manual Generator Controller Manual Web Site:http://www.monicon.com.tw E-mail:sales@monicon.com.tw 1. Controller Description is low cost but multi-function diesel engine generator controller. It applies with 3

More information

DENISON HYDRAULICS Jupiter 500 Driver Card Series S

DENISON HYDRAULICS Jupiter 500 Driver Card Series S Back to Content DENISON HYDRAULICS Jupiter 500 Driver Card Series S20-11712-0 Publ. 9-AM681 E-Mail: denison@denisonhydraulics.com Internet: http://www.denisonhydraulics.com SYSTEM FEATURES SYSTEM FEATURES

More information

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931 Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC

More information

Fire Fighting Diesel Pump Control Panel in Compliance with EN Standard User Manual

Fire Fighting Diesel Pump Control Panel in Compliance with EN Standard User Manual Fire Fighting Diesel Pump Control Panel in Compliance with EN 12845 Standard User Manual Electronic Control Panel Display Panel door-lock Control Buttons Siren Figure 1. Diesel Control Panel - External

More information

PRODUCT INFORMATION BULLETIN

PRODUCT INFORMATION BULLETIN 724-283-4681 724-283-5939 (fax) PRODUCT INFORMATION BULLETIN DESCRIPTION The, Model 10-7100 is one in a series of critical speed switches that monitor speed and detect motion in all types of machinery

More information

Instructions for the BCEA Rotary heat exchanger

Instructions for the BCEA Rotary heat exchanger Instructions for the Rotary heat exchanger 1. General The heat recovery section is a rotary heat exchanger with high temperature and humidification efficiencies. The heat exchanger operates with an efficiency

More information

AUTO-EC-3-E-PLC Electric Filter Backwash Controller Operation & Maintenance Manual

AUTO-EC-3-E-PLC Electric Filter Backwash Controller Operation & Maintenance Manual AUTOEC3EPLC Electric Filter Backwash Controller Operation & Maintenance Manual Contents Contents Controller Basics 3 Controller Components 4 Screen Flow Diagram Controller Functions 6 Installation 7 Warranty

More information

R-200A Digital Controller TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.

R-200A Digital Controller TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit. R-200A Digital Controller TECHNICAL MANUAL A new standard of reliability This manual should remain with the unit. IMPORTANT SAFETY INSTRUCTIONS Save These Instructions The manufacturer suggests that these

More information

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4 CHAPTER ELECTRICAL 2 INSTALLATION Contents of this Chapter... 2.1 Warnings & Agency Approvals..................2 2 2.1.1 Isolation..............................................2 2 2.1.2 Electrical Power

More information

SPA MICROPROCESSOR 3 STAGE PROGRAMMABLE SHIFT LIGHT INSTALLATION AND OPERATING MANUAL PAGE 2...INSTRUMENT FEATURES. PAGE 3...OPERATING INSTRUCTIONS.

SPA MICROPROCESSOR 3 STAGE PROGRAMMABLE SHIFT LIGHT INSTALLATION AND OPERATING MANUAL PAGE 2...INSTRUMENT FEATURES. PAGE 3...OPERATING INSTRUCTIONS. SPA MICROPROCESSOR 3 STAGE PROGRAMMABLE SHIFT LIGHT INSTALLATION AND OPERATING MANUAL PAGE 2...INSTRUMENT FEATURES. PAGE 3...OPERATING INSTRUCTIONS. PAGE 4...MENU SYSTEM. PAGE 6...SPECIFICATIONS. PAGE

More information

Troubleshooting Guide

Troubleshooting Guide Troubleshooting Guide diesel - gasoline - LPG P/N 0172021 June 1999 P.O. Box 1160 St. Joseph, MO 64502-1160 1-800-255-0317 Fax: 816-360-9379 www.snorkelusa.com GENERAL INFORMATION This manual contains

More information

Section 3 Technical Information

Section 3 Technical Information Section 3 Technical Information In this Module: Engine identification Modes of operation Battery charging and heat manage operation Service and repair procedures Maintenance requirements Engine Identification

More information

DASSAULT AVIATION Proprietary Data

DASSAULT AVIATION Proprietary Data F2000EX EASY 02-49-00 CODDE 1 PAGE 1 / 2 TABLE OF CONTENTS 02-49 02-49-00 TABLE OF CONTENTS 02-49-05 GENERAL Introduction Sources Equipment location 02-49-10 DESCRIPTION Introduction Description Operating

More information

60 Series Engine Controls

60 Series Engine Controls ECU 60 Series Engine Controls Use CAUTION since you are applying 120VAC RMS to the AC Input terminals and that it is always potentially their during engine run!!! ECU is a registered trademark of Engineering

More information

Application Examples Nano ICCS with Toggle Function

Application Examples Nano ICCS with Toggle Function Nano ICCS with Toggle Function Fog lamp controller for vehicles integrated into the PCB Fog lamp must be turned on with an impulse signal. The fog lamp can be activated or deactivated via switch, which

More information

DIP SWITCH BASED EARTH LEAKAGE RELAY (ELR) WITH CORE BALANCE CURRENT TRANSFORMER (CBCT / ZCT) EL SERIES

DIP SWITCH BASED EARTH LEAKAGE RELAY (ELR) WITH CORE BALANCE CURRENT TRANSFORMER (CBCT / ZCT) EL SERIES PROK DEVICES PRIVATE LIMITED B-80, 2 nd & 3 rd Floor, KSSIDC Industrial estate, 4 th Main Road, 6 th Block, Rajaji Nagar, Bengaluru -560010 Ph no: 080-41480777, 080-41157700, Email:,, www.prokdvs.in DIP

More information

CruzPro. RPM, Engine Hours, Elapsed Time Gauge RH110. Other CruzPro Products

CruzPro. RPM, Engine Hours, Elapsed Time Gauge RH110. Other CruzPro Products Other CruzPro Products l Depthsounders/w Keel Offset, Deep/Shallow/Anchor Drag Alarms l PC Based DSP Fishfinder for Windows98, NT, SE,XP, 2000 l Speed/Temperature/Logs l Digital DC Volts Gauge/w Alarms

More information

CONTROLLER DIAGNOSTIC GUIDE

CONTROLLER DIAGNOSTIC GUIDE Proprietary tice: This document contains proprietary information which not to be reproduced, transferred, to other documents, disclosed to others, used for manufacturing or any other purpose without the

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE5110 AUTOSTART CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44

More information

TABLE OF CONTENTS. Understanding the Troubleshooting Instructions...2 Signal Light...2 Harness Connections...2 Inspection...2

TABLE OF CONTENTS. Understanding the Troubleshooting Instructions...2 Signal Light...2 Harness Connections...2 Inspection...2 TRIPP Model D ELECTRICAL TABLE OF CONTENTS Understanding the Troubleshooting Instructions...2 Signal Light...2 Harness Connections...2 Inspection...2 LVDT Setup/Adjustments...2 Basic Troubleshooting...3

More information

INSTRUCTION MANUAL. A battery protector for vehicles with equipment that Is operated with the engine not running. MODEL# INPUT: 12 Volts D.C.

INSTRUCTION MANUAL. A battery protector for vehicles with equipment that Is operated with the engine not running. MODEL# INPUT: 12 Volts D.C. INSTRUCTION MANUAL FILE: IM_091-141_Rev_B DATE: 10-02-03 LOAD MANAGER P A battery protector for vehicles with equipment that Is operated with the engine not running MODEL# 091-141 INPUT: 12 Volts D.C.

More information

A3Z OPERATING MANUAL

A3Z OPERATING MANUAL A3Z OPERATING MANUAL TABLE OF CONTENTS Introduction... p. 2 Features... p. 2 Description... p. 3 Theory of Operation... p. 3 Installation... p. 4 Electrical Connections... p. 5 Options... p. 6 Warranty...

More information

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1 Series Bulk Flow Monitor Specifications - Installation and Operating Instructions Bulletin FL-1-4x 3/4 CONDUIT KNOCKOUTS BFS 1A FUSE RED LED RELAY 5-9/64 [130.45] TRANSFORMER 3[76.20] GREEN LED 7 [177.80]

More information

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75 Cascade CD101 Auto-Start Controller Installation and Operations Manual 00-02-0594 2018-02-15 Sections 40 & 75 In order to consistently bring you the highest quality, full featured products, we reserve

More information

5 Series - Mechanical Latch 2PDT - 4PST, 30 Amps

5 Series - Mechanical Latch 2PDT - 4PST, 30 Amps 5 Series - Mechanical Latch 2PDT - 4PST, 30 Amps The 5 series is a 2 coil mechanical latch electrical reset power relay. It is panel mounted with screw terminals, and has 600 volt spacing. The 5 series

More information

PROFIRE 1100i IGNITION FLAME SAFETY CONTROLLER

PROFIRE 1100i IGNITION FLAME SAFETY CONTROLLER PROFIRE 1100i IGNITION FLAME SAFETY CONTROLLER Cautions WARNING: EXPLOSION HAZARD- -DO NOT SERVICE UNLESS AREA IS KNOWN TO BE NON- HAZARDOUS -DO NOT OPEN WHEN ENERGIZED EXPLOSION HAZARD- -SUBSTITUTION

More information

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic CONTENT 1. SUMMARY... 4 2. PERFORMANCE AND CHARACTERISTICS... 4 3. SPECIFICATIONS... 5 4. OPERATION... 6 5. PROTECTION...

More information

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

User Manual. T6 Tachometer. Online:   Telephone: P.O. Box St. Petersburg, Florida 33736 User Manual T6 Tachometer Online: www.phareselectronics.com Telephone: 727-623-0894 P.O. Box 67251 St. Petersburg, Florida 33736 Table of Contents Overview... 1 Description... 1 Wiring... 1 T6 Tachometer

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Coordinate starter needs for mechanical equipment prior to 50% CD and confirm again for 100% CD submittal. B. Coordinate temperature controls requirements

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS PLC DSE720 AUTOSTART CONTROL MODULE OPERATING MANUAL http://bestgenerator.spb.ru/?page_id=6765 Deep Sea Electronics Plc Highfield House Hunmanby North

More information

User Instructions for WRC1021D. Doc

User Instructions for WRC1021D. Doc User Instructions for WRC1021D Doc. 0001-5989 CONTENTS 1.0 INTRODUCTION TO THE WRC1021D... 2 2.0 FUNCTIONAL DESCRIPTION... 3 3.0 POTENTIOMETERS, SWITCHES AND INDICATORS... 5 4.0 CALIBRATION AND START-UP

More information

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Related Sections: 1. Section 15050 - Basic Mechanical Requirements. 2. Section 15051 - Motors. 3. Section 15185 - Hydronic Pumps. 4. Section 15625 - Centrifugal

More information

R-200A R-200C Digital Controller TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.

R-200A R-200C Digital Controller TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit. R-200A R-200C Digital Controller TECHNICAL MANUAL A new standard of reliability This manual should remain with the unit. IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS The manufacturer suggests

More information

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift)

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift) First, Sign and Date Bln 2009-03-9 Updated, Sign and Date Bln 200-04-29 (0) User Manual TTT802 Gearshift Controller Firmware for R--N-2- TTT802 Gearshift Controller, Part # 2-620-9-RN-S (Standard), -P

More information

Fig.11 Powertrain Control Module (PCM)

Fig.11 Powertrain Control Module (PCM) 2003 Dodge or Ram Truck Caravan V6-3.3L VIN R Vehicle > Powertrain Management > Relays and Modules - Powertrain Management > Relays and Modules - Computers and Control Systems > Engine Control Module >

More information

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs. SECTION 16904 MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS PART 2 PRODUCTS 01 MANUFACTURERS A. B. C. Eaton * * The listing of specific manufacturers above does not imply acceptance of their products

More information