FT-1005 Air Volume/Velocity Transducer. Operation & Maintenance Manual. Engineered for accuracy, applicability, durability and simplicity

Size: px
Start display at page:

Download "FT-1005 Air Volume/Velocity Transducer. Operation & Maintenance Manual. Engineered for accuracy, applicability, durability and simplicity"

Transcription

1 FT-1005 Air Volume/Velocity Transducer Operation & Maintenance Manual Engineered for accuracy, applicability, durability and simplicity

2 TABLE OF CONTENTS TABLE OF CONTENTS INTRODUCTION DESCRIPTION Installation Setup Component & Adjust location POWER SUPPLY POWER SUPPLY CHECK CALIBRATION DPT ZERO CALIBRATION CURRENT ZERO OUTPUT CALIBRATION DPT SPAN CALIBRATION OUTPUT SPAN CALIBRATION vdc Output Procedure mA Output Procedure TROUBLESHOOTING GUIDE...5

3 1. INTRODUCTION This user manual provides information on product features and guides you through all basic functionality DESCRIPTION The FT-1005 Air Volume transducer sensor operates on the capacitance principal and is capable of sensing ultra low differential pressures. In the capacitance cell, a very lightweight, responsive diaphragm deflects a small amount when pressure is applied. This deflection results in a change in capacitance, which is then detected and processed electronically into an output signal linear to the velocity pressure. The electronic signal is then sent to the square root extractor/multiplier, which converts the velocity pressure signal into an analog output signal (4-20mA / 0-10vdc) linear to velocity (fpm) or volume (cfm). An integral green LED indicator verifies proper power supply operation Installation Setup Refer to figures below for pressure and electrical connections. PRESSURE CONNECTIONS ELECTRICAL CONNECTIONS LOW PRESSURE CONNECTION HIGH PRESSURE CONNECTION FT AIR VOLU TRAN Model No: OUTPUT POWER DMM / RECEIVER - POWER SUPPLY 24VAC/DC (NOTE:POWER INPUT IS NOT POLARITY SENSITIVE) Component & Adjust location POWER - + OUTPUT DC/DC CONVERTER POWER INDICATOR REMOVEABLE FUSE (1.5AMP) VOLTAGE/CURRENT OUTPUT SELECTION JUMPER V I H1 F1 TP1 +15VDC TP2-15VDC TP3 DPT SIG. TP4 SQ.RT. TP5 SQ.RT./LD BAL. R44 SQ.RT. DPT SPAN SPAN DPT ZERO OUTPUT ZERO R38 OUTPUT SPAN R33 TP6 GND R21 R16 R13 1 Paragon Controls Incorporated, Rev.V1.0,11/17/09

4 2. POWER SUPPLY The FT-1005 transducer electronics requires ±15vdc power levels to function properly. Perform the following checks to verify all voltages are within factory specifications POWER SUPPLY CHECK The following power supply check will require a DMM connected between TP6 (GND) and the +15vdc and -15vdc test points. See figure shown in section1.1.2 for component location. Step 1. Apply power to the FT-1005 transducer. Step 2. Verify the green power LED (LED1) is illuminated. Step 3. With the DMM, monitor the voltage between TP6 (GND) and TP1 (+15vdc). Verify a reading of +15 ±0.6vdc. Step 4. With the DMM, monitor the voltage between TP6 (GND) and TP2 (-15vdc). Verify a reading of -15 ±0.6vdc. 2 Paragon Controls Incorporated, Rev.V1.0,11/17/09

5 3. CALIBRATION It is recommended that the Zero Calibration be performed upon installation. Span Calibration is not effected by the Zero Calibration. The Span of the unit has been factory calibrated and should only be adjusted using high accuracy test equipment. Refer to section for setup configuration DPT ZERO CALIBRATION The following zero calibration procedure can be performed without the need to perform a span calibration. Step 1. Apply power to the FT-1005 transducer. Step 2. Verify the green power LED (LED1) is illuminated. Step 3. Verify zero pressure is applied to the transducer. Step 4. With the DMM, monitor the voltage between TP6 (GND) and TP3 (DPT SIG.). Adjust R13 (DPT ZERO) potentiometer for a reading of 0.0 ± 0.001vdc CURRENT ZERO OUTPUT CALIBRATION Step 1. Check the FT-1005 label and verify output signal type (Voltage / Current). Step 2. Connect the DMM to the output terminals and set the DMM for the appropriate output signal type. Step 3. Apply power to the FT-1005 transducer. Step 4. With no pressure applied, adjust R38 (OUTPUT ZERO) potentiometer for a reading of 4.0 ± 0.01mA DPT SPAN CALIBRATION Step 1. Apply power to the FT-1005 transducer. Step 2. Connect the DMM between TP6 (GND) and TP3 (DPT SIG.). Step 3. Apply full scale pressure (Value shown on the transducer label) to the High Pressure port and adjust R16 (DPT SPAN) potentiometer for a reading of 10±.01vdc OUTPUT SPAN CALIBRATION Check the transducer label to determine the output signal type (0-10vdc or 4-20mA) and perform the appropriate output procedure. Note: It is recommended that a zero calibration be completed before performing a span calibration. Equipment Required - Low pressure air source (Paragon PS-100 or equivalent) - Manometer for measuring low pressure - DMM (Digital Multi Meter) 3 Paragon Controls Incorporated, Rev.V1.0,11/17/09

6 vdc Output Procedure Step 1. Connect the DMM to the output terminals and configure the DMM for voltage readings. Step 2. Apply power to the FT-1005 transducer. Step 3. Apply full scale pressure (Value shown on the transducer label) to the High Pressure port and adjust R33 (OUTPUT SPAN) potentiometer for a reading of 10±.01vdc mA Output Procedure Step 1. Connect the DMM to the output terminals and configure the DMM for current readings. Step 2. Apply power to the FT-1005 transducer. Step 3. Apply full scale pressure (Value shown on the transducer label) to the High Pressure port and adjust R33 (OUTPUT SPAN) potentiometer for a reading of 20±.01mA. 4 Paragon Controls Incorporated, Rev.V1.0,11/17/09

7 4. TROUBLESHOOTING GUIDE TROUBLESHOOTING TABLE SYMPTOM 1. Power LED1 not illuminated SOLUTION 1. Verify power to device is within specifications 2. Verify F1 fuse 3. Contact Factory Service Department. 2. Incorrect output signal reading 1. Verify correct H1 output jumper selection 2. Verify low Pressure and High Pressure signal lines are connected correctly (See section 1.1.1). 3. Verify receiving device is configured correctly 4. Contact Factory Service Department. 5 Paragon Controls Incorporated, Rev.V1.0,11/17/09

8 Paragon Controls Incorporated P.O. Box 99, Forestville, CA Phone 707 / Fax 707 / IOM: FT-1005 RevV1.0,11/17/09 Copyright 2009

Technical Data Sheet FT & FIT-1003 SERIES AIR VOLUME/ VELOCITY TRANSDUCERS. Features DESCRIPTION

Technical Data Sheet FT & FIT-1003 SERIES AIR VOLUME/ VELOCITY TRANSDUCERS. Features DESCRIPTION Technical Data Sheet FT & FIT-1003 SERIES AIR VOLUME/ VELOCITY TRANSDUCERS DESCRIPTION FT & FIT-1003 Series transducers include Models FT-1003, FT-1003-ZV, FIT-1003-D, FIT-1003-DZV, FIT-1003-M, and FIT-1003-MZV.

More information

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

Mid-West Instrument. Series 700 Wet/Wet Installation and Operating Instructions. Differential Pressure Transmitter Mid-West Instrument IM_700/A Series 700 "Wet/Wet" Installation and Operating Instructions Differential Pressure Transmitter 6500 Dobry Dr. Sterling Heights, MI USA Toll Free: 800-648-5778 Ph 586-254-6500

More information

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series) Overview The BAPI-Stat 4 Style room unit is available as a humidity only sensor or as a combination temperature and humidity sensor with optional LCD display, temperature setpoint adjustment and occupant

More information

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

User Manual. T6 Tachometer. Online:   Telephone: P.O. Box St. Petersburg, Florida 33736 User Manual T6 Tachometer Online: www.phareselectronics.com Telephone: 727-623-0894 P.O. Box 67251 St. Petersburg, Florida 33736 Table of Contents Overview... 1 Description... 1 Wiring... 1 T6 Tachometer

More information

1100 Series Piston Type Differential Pressure Gauges

1100 Series Piston Type Differential Pressure Gauges 1100 Series Piston Type Differential Pressure Gauges 1. Safety Before installing, check the Series Number and verify compatibility to the process media and temperature in contact with the wetted parts.

More information

T21 Thermal Differential Switch

T21 Thermal Differential Switch T21 Thermal Differential Switch General Instructions The T21 Point Level Switch is a state-of-the-art in liquid level and interface measurement and control. Level detection is accomplished by using a high-resolution

More information

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY 222 W. Memorial Road, Oklahoma City, OK 73114-2317 Phone: 1-800-624-7697 Fax: 405-755-8425 www.magpowr.com E-mail: magpowr@magpowr.com INSTRUCTION MANUAL MODEL PS-24 24 VDC POWER SUPPLY All of the information

More information

VT-SENSOR AIR VELOCITY AND TEMP

VT-SENSOR AIR VELOCITY AND TEMP home VTSENSOR AIR VELOCITY AND TEMP Ultra low velocity pressure measurement Traceable Calibration Certificate Excellent repeatability Self compensating zero Climate chamber compensated Long term span stability

More information

SETRA Operating Instructions Series DPT 230 Pressure Transducers

SETRA Operating Instructions Series DPT 230 Pressure Transducers SETRA Operating Instructions Series DPT 230 Pressure Transducers GENERAL INFORMATION Your Setra Pressure Transducer has been carefully tested and calibrated before shipment. Specific performance information

More information

PEAKTRONICS DMC-101 ADDITIONAL FEATURES. DC Motor Controller, 5A DMC-101

PEAKTRONICS DMC-101 ADDITIONAL FEATURES. DC Motor Controller, 5A DMC-101 PEAKTRONICS The Peaktronics DC Motor Controller is used for proportional positioning of actuators that use either DC motors or DC solenoids. The wide operating range of the (10 to 30 VDC and loads up to

More information

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

DPT-2015 Differential Pressure Transmitter for VAV Box Applications Installation Instructions DPT-2015 Issue Date June 25, 2015 DPT-2015 Differential Pressure Transmitter for VAV Box Applications Installation Parts Included DPT-2015 transmitter two No. 6 x 1/4 in. thread-forming

More information

V-SENSOR LOW AIR VELOCITY SENSOR

V-SENSOR LOW AIR VELOCITY SENSOR home VSENSOR LOW AIR VELOCITY SENSOR Ultra low velocity pressure measurement Traceable Calibration Certificate Excellent repeatability Self compensating zero Climate chamber compensated Long term span

More information

5001TCP SPEED CONTROLLER

5001TCP SPEED CONTROLLER INSTALLATION AND SETTING UP MANUAL 5001TCP SPEED CONTROLLER WARNING Disconnect all incoming power before working on this equipment. Follow power lockout procedures. Use extreme caution around electrical

More information

AC10 Measuring System

AC10 Measuring System P-2012-2 819-0402 AC10 Measuring System Installation Instructions Contents Introduction............................ 2 System Overview....................... 3 AC10 Tensioncells...................... 4

More information

MM1/MM2 INSTALLATION & MAINTENANCE INSTRUCTIONS

MM1/MM2 INSTALLATION & MAINTENANCE INSTRUCTIONS MM1/MM2 INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION / IDENTIFICATION The MM series proportional control valves utilize ProportionAir's unique closed loop control technology for superior control

More information

AD-1251 Probe with Differential Pressure Transducer

AD-1251 Probe with Differential Pressure Transducer AD-1251 Probe with Differential Pressure Transducer Product Bulletin Code No. LIT-12011473 Issued October 31, 2011 Supersedes September 6, 2011 The AD-1251 Probe with Differential Pressure Transducer (DPT)

More information

OPERATIONS & INSTALLATION MANUAL

OPERATIONS & INSTALLATION MANUAL www.thermalinstrument.com 217 Sterner Mill Road Trevose, PA 19053 U.S.A. P: 215-355-8400 F: 215-355-1789 Info@ThermalInstrument.com OPERATIONS & INSTALLATION MANUAL CUSTOMER NAME: CUSTOMER PO#: SERIAL

More information

GE Sensing & Inspection Technologies

GE Sensing & Inspection Technologies GE Sensing & Inspection Technologies Modus Model RPM-1 Room Pressure Monitor Installation and Setup Guide 1. GENERAL The RPM-1 monitors either positive or negative room pressures (see the Datasheet for

More information

Product Guide: Series III Pump Control Board Set (RoHS)

Product Guide: Series III Pump Control Board Set (RoHS) revised 04/08/10 Description: The Series III Pump Control Board Set provides motor drive and pump control for a wide assortment of pumps from Scientific Systems, Inc. The assembly consists of two circuit

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

RESISTIVITY MONITOR/CONTROLLERS

RESISTIVITY MONITOR/CONTROLLERS RESISTIVITY MONITOR/CONTROLLERS Installation Operation Maintenance User Manual for Models: 750, 752, 753, 762 2450 Impala Drive Carlsbad, CA 92010-7226 USA Tel: 1-760-438-2021 Fax: 1-800-869-7668 / 1-760-931-9189

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary

More information

5001TCP SPEED CONTROLLER

5001TCP SPEED CONTROLLER VARIABLE SPEED DRIVE CONTROLLER INSTALLATION AND SETTING UP MANUAL 5001TCP SPEED CONTROLLER With PC101 Torque Limit Control WARNING Disconnect all incoming power before working on this equipment. Follow

More information

CP-8551 & CP Application. Features. Applicable Literature. Electronic to Pneumatic Transducers General Instructions

CP-8551 & CP Application. Features. Applicable Literature. Electronic to Pneumatic Transducers General Instructions CP-8551 & CP-8552 Electronic to Pneumatic Transducers General Instructions Application The CP-8551 and CP-8552 transducers receive a variable electronic input signal and produce a 3 to 15 psig (21 to 103

More information

DC Variable Speed Drive Panel

DC Variable Speed Drive Panel DC Variable Speed Drive Panel Installation, Operation & Maintenance Instruction Manual Bulletin #: CC-IOM-0103-D Manufacturers of Quality Pumps, Controls and Systems ENGINEERED PUMP OPERATIONS 2883 Brighton

More information

Contents. Pressure measurement technology Pressure calibrators 18 Exercises 19-20

Contents. Pressure measurement technology Pressure calibrators 18 Exercises 19-20 1 Pressure Contents Topics: Slide No: Pressure measurement technology 03-17 Pressure calibrators 18 Exercises 19-20 2 Pressure Gauges Barometer Used to measure Barometric Pressure Reference is 0 psia,

More information

Troubleshooting Bosch Proportional Valves

Troubleshooting Bosch Proportional Valves Troubleshooting Bosch Proportional Valves An Informative Webinar Developed by GPM Hydraulic Consulting, Inc. Instructed By Copyright, 2009 GPM Hydraulic Consulting, Inc. TABLE OF CONTENTS Bosch Valves

More information

Current Switches and Transducers

Current Switches and Transducers Current Switches and Transducers Models CT-800,-805, -810, -815, -820, -825, -830 and CU-850, -855, -860, -865, -870, -875, -880, and -885 Easy to install... Small size, built-in mounting flanges, and

More information

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version MD10 Engine Controller Installation and User Manual for the MD10 Engine Controller. Full Version File: MartinMD10rev1.4.doc May 16, 2002 2 READ MANUAL BEFORE INSTALLING UNIT Receipt of shipment and warranty

More information

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry. Precision Airflow Measurement An ONICON Brand

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry. Precision Airflow Measurement An ONICON Brand CAMS Combustion Airflow Management System Proven solutions for a tough industry Precision Airflow Measurement An ONICON Brand CAMS TM Combustion Airflow Management System Product Description The Air Monitor

More information

Hoffman Controls. Installation & Operating Instructions. General. Installation. Determining Damper Shaft Rotation. Stop Pin Installation

Hoffman Controls. Installation & Operating Instructions. General. Installation. Determining Damper Shaft Rotation. Stop Pin Installation Hoffman Controls Installation & Operating Instructions General 1. This instruction is a guide for connecting and operating the 200-3 Series Flow Controller with the 207 Series Thermostat and the 241-2

More information

Blancett Flow Meters A Division of Racine Federated Inc. 100 East Felix Street South, Suite 190 Fort Worth, Texas FAX:

Blancett Flow Meters A Division of Racine Federated Inc. 100 East Felix Street South, Suite 190 Fort Worth, Texas FAX: Active Sensor Installation and Operation Manual - Preliminary Frequency-to-Current/ Frequency-to-Voltage Converter For use with Blancett Model 1100 Series Turbine Flow Meters Introduction The Active Sensor

More information

Calibration and Performance Check: Agilent Dual Plasma Controller

Calibration and Performance Check: Agilent Dual Plasma Controller Calibration and Performance Check: Agilent Dual Plasma Controller Purpose Outline the steps used to calibrate and verify the performance of the Agilent Technologies Dual Plasma Controller. Scope This procedure

More information

FOR USE IN SOLUTION AIR HANDLING UNITS

FOR USE IN SOLUTION AIR HANDLING UNITS AMS-60 AIRFLOW MONITORING DEVICE APPLICATION GUIDE Supersedes: NOTHING Form 102.20-AG1 (303) FOR USE IN SOLUTION AIR HANDLING UNITS GENERAL The YORK AMS-60 is an airflow monitoring device which combines

More information

Figure 1: WPR2 Dimensions and Hardware

Figure 1: WPR2 Dimensions and Hardware Installation and Operation Instructions WPR2 Series (Max. Line Pressure < 300 PSI) Wet to Wet Differential Pressure Ø0.200" 2.60" 4.47" 5.47" 5.28" 3.00" Precautions Figure 1: WPR2 Dimensions and Hardware

More information

MODEL 422 Submersible Pump Controller

MODEL 422 Submersible Pump Controller MODEL 422 Submersible Pump Controller Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or 240VAC, Single-phase or 3-phase Built-in Trip and

More information

DENISON HYDRAULICS Jupiter 500 Driver Card Series S

DENISON HYDRAULICS Jupiter 500 Driver Card Series S Back to Content DENISON HYDRAULICS Jupiter 500 Driver Card Series S20-11712-0 Publ. 9-AM681 E-Mail: denison@denisonhydraulics.com Internet: http://www.denisonhydraulics.com SYSTEM FEATURES SYSTEM FEATURES

More information

CO 2 Room Sensor in the BAPI-Stat Quantum Prime Style Enclosure

CO 2 Room Sensor in the BAPI-Stat Quantum Prime Style Enclosure Identification and Overview The BAPI CO 2 Sensor is an accurate and reliable way of incorporating demand controlled ventilation into a building s HVAC strategy. It measures the CO 2 in a range of 0 to

More information

PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT

PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT Sheet 1 of 6 Order Number Serial Number PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT Issue Date Level A 22/10/02 Initial issue. Summary of changes Due to RMS continuous product improvement policy

More information

Low Pressure Sensor. Overview. Specifications. Installation and Operation

Low Pressure Sensor. Overview. Specifications. Installation and Operation Overview The Low Pressure Sensor with display measures building pressure, air velocities and volumes. The heart of the unit is a micro-machined silicon pressure sensor. The unit includes a static pressure

More information

H2B-ACDC H3B-ACDC H5B-ACDC. 1 Channel Current Sensor 2 Channel Current Sensor. 3 Channel Current Sensor 5 Channel Current Sensor

H2B-ACDC H3B-ACDC H5B-ACDC. 1 Channel Current Sensor 2 Channel Current Sensor. 3 Channel Current Sensor 5 Channel Current Sensor The HXB-ACDC-XX fixed offset, fixed gain series Hall effect current sensor transducer board delivers output voltage proportional to the amount of current detected in the wire being measured. HB-ACDC H2B-ACDC

More information

AGELKOM CAP04V-9 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines Height Sensor & Controller

AGELKOM CAP04V-9 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines Height Sensor & Controller AGELKOM CAP04V-9 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines Height Sensor & Controller 9 PIN D-SUB INTERFACE CAP 04 CAPACITIVE HEIGHT CONTROLLER IN POSITION CABLE FAULT Description:

More information

SPM-15 SONIC PROBE. Copyright Lakewood Systems Ltd. March 1992 Printed August 22, 2008 Rev A, SPM-15.DOC,

SPM-15 SONIC PROBE. Copyright Lakewood Systems Ltd. March 1992 Printed August 22, 2008 Rev A, SPM-15.DOC, SPM-15 SONIC PROBE Copyright Lakewood Systems Ltd. March 1992 Printed August 22, 2008 Rev A, SPM-15.DOC, U.S. CORPORATE HEADQUARTERS 9477 Greenback Lane, #527, Folsom, CA, U.S.A. 95630 CANADIAN CORPORATE

More information

Radnoti Isometric Force Transducer A

Radnoti Isometric Force Transducer A Radnoti 2006 Radnoti Isometric Force Transducer 159901A Use of Radnoti 159901A Isometric Force Transducer This transducer operates on the principle of converting picofarad capacitance changes into an amplified

More information

Condensed Version of Operator s Manual For The VI/VP700 Series Flowmeter and VI800 Series Flowmeter

Condensed Version of Operator s Manual For The VI/VP700 Series Flowmeter and VI800 Series Flowmeter Condensed Version of Operator s Manual For The VI/VP700 Series Flowmeter and VI800 Series Flowmeter Warranty Agreement J-TEC Associates warrants this product to be in good working order for a period of

More information

Operations Manual. Zero Speed Switch Sensor Model ZS09P

Operations Manual. Zero Speed Switch Sensor Model ZS09P Zero Speed Switch Sensor Model ZS09P The must be referred to for correct installation. Failure to comply with the shall void all warranties and liabilities. Overview The Phares Electronics Model ZS09P

More information

USERS MANUAL MCD REMOTE OPERATOR

USERS MANUAL MCD REMOTE OPERATOR USERS MANUAL MCD REMOTE OPERATOR Order Code: 175G9004, 175G3061 Contents Contents Introduction...2 Important User Information...2 General Description...2 Symbols Used in this Manual...2 Installation...3

More information

EMaSM. Principles Of Sensors & transducers

EMaSM. Principles Of Sensors & transducers EMaSM Principles Of Sensors & transducers Introduction: At the heart of measurement of common physical parameters such as force and pressure are sensors and transducers. These devices respond to the parameters

More information

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited. SERVICE MANUAL ELECTRIC BRAISING PANS (30 & 40 GALLON) VE30 VE40 ML-126849 ML-126850 VE40 SHOWN - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used

More information

Model 930 Power Control System Instruction Manual

Model 930 Power Control System Instruction Manual Model 930 Power Control System Instruction Manual Publication No. A105328-001 Rev A December 2000 Another quality product from: 7128 Shady Oak Rd, Eden Prairie MN 55344 Phone: (952) 949-9009 Fax: (952)

More information

Beck. The differential pressure transmitter for air with IP65

Beck. The differential pressure transmitter for air with IP65 Beck. The differential pressure transmitter for air with IP65 Differential pressure transmitter 985 with IP65 General description The differential pressure transmitters of the 985 series are used to measure

More information

17429X.00 SERIES MODELS:

17429X.00 SERIES MODELS: LEESON ELECTRIC MOTORS, GEARMOTORS AND DRIVES R User s Manual 17429X.00 SERIES MODELS: 174298.00 174299.00 PWM REGENERATIVE DC TO DC DRIVES II Table of Contents 17429X.00 Drives...............................................................

More information

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES MODE 729 Micro-differential Pressure High-precision Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1563~ guide... P.699~ General precautions...

More information

DMC mA Positioner

DMC mA Positioner DMC-100 4-20mA Positioner TELEPHONE: +1-859-727-7890 TOLL FREE: +1-800-662-9424 FAX: +1-859-727-4070 E-MAIL: DVOGES@INDELAC.COM MROBINSON@INDELAC.COM TCAYWOOD@INDELAC.COM SHIPPING ADDRESS: 6810 POWERLINE

More information

ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER

ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com BST-IT26 ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER INSTRUCTION MANUAL Index

More information

SR1V. Industrial Low Cost String Pot

SR1V. Industrial Low Cost String Pot SR1V Industrial Low Cost String Pot User Scalable VDC Output Signal Linear Position Measurement up to 125 inches (3 meters) Designed for Outdoor / Wet environments In-Stock! SR1V is a rugged, low-cost,

More information

Instruction Manual. Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY Fax

Instruction Manual. Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY Fax Instruction Manual Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY 12072 1-800-833-0081 Fax 518-922-8997 www.anderson-negele.com Instrument Model Number Instrument Serial Number Form

More information

MANUAL TROUBLESHOOTING. ECM Motor. ECM / ECM-DX Series. v100 Issue Date: 08/15/ Price Industries Limited. All rights reserved.

MANUAL TROUBLESHOOTING. ECM Motor. ECM / ECM-DX Series. v100 Issue Date: 08/15/ Price Industries Limited. All rights reserved. MANUAL ECM Motor ECM / ECM-DX Series v100 Issue Date: 08/15/17 2017 Price Industries Limited. All rights reserved. ECM MOTOR TABLE OF CONTENTS ECM Motor Background...1 ECM Motor Power and Control Connectors...2

More information

Differential Pressure Sensors

Differential Pressure Sensors 1 910 1910P01 Differential Pressure Sensors for air or nonaggressive gases QBM66... Pressure-linear characteristic with selectable pressure measuring range Operating voltage AC 24 V or DC 13.5...33 V Output

More information

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A Mid-West Instrument BULLETIN NO.ELEC IM121/10A Replaces IM121/09A INSPECTION Model 121 Indicating Differential Pressure Switch / Transmitter Electrical: Installation and Operating Instructions Upon receipt

More information

MAGPOWR Spyder-Plus-S1 Tension Control

MAGPOWR Spyder-Plus-S1 Tension Control MAGPOWR TENSION CONTROL MAGPOWR Spyder-Plus-S1 Tension Control Instruction Manual Figure 1 EN MI 850A351 1 A COPYRIGHT All of the information herein is the exclusive proprietary property of Maxcess International,

More information

ASYN205B Central Synchronizing Controller

ASYN205B Central Synchronizing Controller ASYN205B Central Synchronizing Controller Function 3 phase active power transducer, one auxiliary analog Genset power control Genset voltage frequency control Multi-gensets power balance control Selectional

More information

Compact Pressure Transmitter DAN-HH

Compact Pressure Transmitter DAN-HH 1 Product Information DAN-HH Compact Pressure Transmitter DAN-HH Application / Specified Usage Authorizations Pressure measurement in pipes and vessels High Temperature applications up to 150 C permanent

More information

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE MEMBER GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA 01001-2907, USA LSM672 LOAD SHARING MODULE PRODUCT TECHNICAL INFORMATION PTI 4000 AUGUST

More information

Radnoti Modular Wire Myograph System Assembly and Basic Principles

Radnoti Modular Wire Myograph System Assembly and Basic Principles Radnoti Modular Wire Myograph System Assembly and Basic Principles www.radnoti.com info@radnoti.com Copyright 2017 v. 17 List of Components for the M1000 The Radnoti M1000 is the start of the Wire Myograph

More information

Visit our web site at AMR LS-3000, LS-3010 & LS-3020 BELT SLIP/SEQUENCE CONTROL INSTALLATION AND SETUP INSTRUCTIONS

Visit our web site at   AMR LS-3000, LS-3010 & LS-3020 BELT SLIP/SEQUENCE CONTROL INSTALLATION AND SETUP INSTRUCTIONS AMR INC. DESIGN & MANUFACTURING FOR MINING WORLDWIDE P.O. BOX 234, ROCKY GAP, VA 24366 PHONE (276)928-1712 FAX (276)928-1814 Email sales@americanmineresearch.com Visit our web site at www.americanmineresearch.com

More information

C1 Controller & Driver. User s Guide

C1 Controller & Driver. User s Guide Controller & Driver User s Guide Page 1 of 12 Table of Contents Warnings & Notices 2 Quick Start Procedure 3 Factory Default Settings 4 System Setup Position 5 Force 5 Pressure 5 Flow 6 Wiring 7 Potentiometers/Tuning

More information

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

Product Overview. Product Identification. Amps One CT Two CTs Three CTs AH06 (optional mounting bracket for small, medium, and large CTs) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

CHAPTER 4 VARIABLE COMPRESSION RATIO ENGINE WITH DATA ACQUISITION SYSTEM

CHAPTER 4 VARIABLE COMPRESSION RATIO ENGINE WITH DATA ACQUISITION SYSTEM 57 CHAPTER 4 VARIABLE COMPRESSION RATIO ENGINE WITH DATA ACQUISITION SYSTEM 4.1 GENERAL The variable compression ratio engine was developed by Legion brothers, Bangalore, India. This chapter briefly discusses

More information

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1 Series Bulk Flow Monitor Specifications - Installation and Operating Instructions Bulletin FL-1-4x 3/4 CONDUIT KNOCKOUTS BFS 1A FUSE RED LED RELAY 5-9/64 [130.45] TRANSFORMER 3[76.20] GREEN LED 7 [177.80]

More information

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES MODE 751 Micro-differential Pressure High-precision Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.1469 ~ Sensor selection guide...

More information

Installation, Operation & Maintenance Manual

Installation, Operation & Maintenance Manual Installation, Operation & Maintenance Manual MONITORS www.lakemonitors.com Lake Monitors 8809 Industrial Drive, Franksville, WI 53126 P: (800) 850-6110 (262) 884-9800 F: (262) 884-9810 MONITORS 2007 AW-Lake

More information

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH 331-SV User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER Ashland, OH 800-363-5842 WWW.PRIMEXCONTROLS.COM Warranty void if panel is modified. Call factory with servicing

More information

Differential Pressure Sensors

Differential Pressure Sensors 1 910 1910P01 Differential Pressure Sensors for air or nonaggressive gases QBM66... Pressure-linear characteristic with selectable pressure measuring range Operating voltage AC 24 V or DC 13.5...33 V Output

More information

The IAQ50 Air Damper/Monitor Installation and Maintenance Manual

The IAQ50 Air Damper/Monitor Installation and Maintenance Manual The IAQ50 Air Damper/Monitor Installation and Maintenance Manual RUSKIN MANUFACTURING 3900 Dr. Greaves Road Kansas City, Missouri 64030-1183 U.S.A. ! WARNING DO NOT TAMPER WITH (REMOVE, REPLACE, RELOCATE

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 47681 Vari-Green Motor and Controls Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

ATP-2040 Electric Damper Actuator/Transmitter

ATP-2040 Electric Damper Actuator/Transmitter ATP-2040 Electric Damper Actuator/Transmitter Kit Includes 1. Actuator/Transmitter package: factory assembled Actuator (EDA-2040) and Transmitter (DPT-2000). Product Code Number Coupler Size Differential

More information

Spray Height Controller

Spray Height Controller Spray Height Controller UC5 SERVICE MANUAL 2012 Printed in Canada Copyright 2012 by NORAC Systems International Inc. Reorder P/N: UC5 SERVICE MANUAL 2012 Rev B NOTICE: NORAC Systems International Inc.

More information

CO 2 Room Sensor in the BAPI-Stat 3 Enclosure with Common Ground Configuration

CO 2 Room Sensor in the BAPI-Stat 3 Enclosure with Common Ground Configuration Identification and Overview The BAPI CO 2 Sensor is an accurate and reliable way of incorporating demand controlled ventilation into a building s HVAC strategy. It measures the CO 2 in a range of 0 to

More information

Section Five - Troubleshooting Procedures

Section Five - Troubleshooting Procedures Section Five - Troubleshooting Procedures Note: This section contains troubleshooting procedures specific to the C96X family of treadmills. Please refer to the troubleshooting procedures in the commercial

More information

Operation and Maintenance Instructions Manual BOOSTER. Volume amplifier

Operation and Maintenance Instructions Manual BOOSTER. Volume amplifier Operation and Maintenance Instructions Manual BOOSTER Volume amplifier 1. GENERAL INFORMATION... 3 2. TECHNICAL SPECIFICATIONS... 3 3. DIMENSIONAL DESIGN... 4 3.1 BOOSTER WITHOUT SIGNAL ADAPTER... 4 3.2

More information

AUTO PUMP STATUS CENTER

AUTO PUMP STATUS CENTER INSTRUCTION MANUAL AUTO PUMP STATUS CENTER VOLTAGE & PRESSURE MODEL #: 091-198-12-PP File: IM_091-198-12-PP_revD.indd Rev: D Revised By: MFG/PSS Date: 1-30-2015 3 YEAR WARRANTY scan using your mobile device

More information

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951) SPI Mag MODEL 282L SINGLE POINT INSERTION ELECTROMAGNETIC FLOW METER 2 SENSOR SUBMITTAL PACKAGE From McCROMETER, INC. 3255 WEST STETSON AVENUE HEMET, CA 92545 Phone (951) 652-6811 Toll Free (800) 220-2279

More information

PRODUCT/TEST MANUAL 2C58K37 INSTANTANEOUS OVERCURRENT RELAY

PRODUCT/TEST MANUAL 2C58K37 INSTANTANEOUS OVERCURRENT RELAY Sheet 1 of 7 Order Number Serial Number PRODUCT/TEST MANUAL 2C58K37 INSTANTANEOUS OVERCURRENT RELAY Issue Date Level C /04/1996 Initial issue. Summary of changes Due to RMS continuous product improvement

More information

A6Z OPERATING MANUAL

A6Z OPERATING MANUAL A6Z OPERATING MANUAL TABLE OF CONTENTS Introduction... p. 2 Features... p. 2 Description... p. 3 Theory of Operation... p. 3 Installation... p. 4 Electrical Connections... p. 5 Options... p. 6 Warranty.p.

More information

Model 124 Filter Minder & Model 124

Model 124 Filter Minder & Model 124 Installation & Maintenance Instructions Model 124 Filter Minder & Model 124 Indicating Differential Pressure Switch / Transmitter Reading Office Cutbush Park, Danehill, Lower Earley, Reading, Berkshire.

More information

199.9 µa to A *, mv (AC or DC) * Accessory Shunts Available For Higher Current Ranges.

199.9 µa to A *, mv (AC or DC) * Accessory Shunts Available For Higher Current Ranges. Bulletin No. PAXLI/V-C Drawing No. LP0566 Released 10/07 MODEL PAXLI - PAX LITE CURRENT METERS & MODEL PAXLV - PAX LITE VOLTMETERS FOUR MULTI-RANGE UNITS COVER: 199.9 µa to 1.999 A *, 199.9 mv (AC or DC)

More information

AQUASWITCH AQUASWITCH & 760-A AQUASWITCH

AQUASWITCH AQUASWITCH & 760-A AQUASWITCH AQUASWITCH AQUASWITCH & 760-A AQUASWITCH Operation Manual INSTALLATION OPERATION MAINTENANCE 22 August 05 ACCURACY RELIABILITY SIMPLICITY Water Quality Instrumentation Accuracy Reliability Simplicity TABLE

More information

1994 Mazda MX-5 Miata. D - ADJUSTMENTS 1994 ENGINE PERFORMANCE Mazda - On-Vehicle Adjustments ENGINE PERFORMANCE Mazda - On-Vehicle Adjustments

1994 Mazda MX-5 Miata. D - ADJUSTMENTS 1994 ENGINE PERFORMANCE Mazda - On-Vehicle Adjustments ENGINE PERFORMANCE Mazda - On-Vehicle Adjustments ENGINE MECHANICAL D - ADJUSTMENTS 1994 ENGINE PERFORMANCE Mazda - On-Vehicle Adjustments Before performing any on-vehicle adjustments to fuel or ignition systems, ensure engine mechanical condition is

More information

Start-Up, Operation and Service Instructions

Start-Up, Operation and Service Instructions Article I. Krueger Proportional LineaHeat W/ Discharge Temperature Start-Up, Operation and Service Instructions SAFETY NOTE Air-handling equipment will provide safe and reliable service when operated within

More information

User Manual. PolyGard AT-3300_V2. Catalytic bead analog combustible Gas Transmitter Serial no. AT _V2. July 23, 2007 GAAT3300I05V2

User Manual. PolyGard AT-3300_V2. Catalytic bead analog combustible Gas Transmitter Serial no. AT _V2. July 23, 2007 GAAT3300I05V2 PolyGard AT-00_V Catalytic bead analog combustible Gas Transmitter Serial no. AT-00-0-000-0_V User Manual July, 007 User Manual - PolyGard AT-00-V Page Catalytic bead analog combustible Gas Transmitter

More information

Technical Service Bulletin AGC Installation Procedure for Paragon and DCX Series Transmitters

Technical Service Bulletin AGC Installation Procedure for Paragon and DCX Series Transmitters Technical Service Bulletin 130812 AGC Installation Procedure for Paragon and DCX Series Transmitters Service Bulletin 130812 details the installation and adjustment of the Total System AGC supplied with

More information

Ultrasonic Sensor U-B

Ultrasonic Sensor U-B MAINTAIN CONSTANT TENSION - The ultrasonic sensor is used to maintain constant tension when using a brake for producing unwind (payout) tension, or when using a clutch for rewind tension. The sensor measures

More information

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual K0 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual Pneumatic Connection Outlet Port Gauge Single Acting Actuator (Spring Return): For single acting actuators Outlet Port 2 is to be plugged.

More information

Silver Series Thermal Dispersion Airflow Measurement Technology

Silver Series Thermal Dispersion Airflow Measurement Technology Thermal Dispersion Airflow Measurement Model STx104-U Unit Ventilator Airflow Measurement System Technical Data Silver Series Thermal Dispersion Airflow Measurement Technology APPLICATIONS Direct outdoor

More information

Air Quality Solutions

Air Quality Solutions Air Quality Solutions Installation & Maintenance Manual Model: IAQ50X Air Measuring Station Indoor Air Quality Damper II-IAQ50X-818/Replaces II-IAQ50X-612 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE

More information

Sensor systems. Type Differential pressure transducer. For the differential pressure recording and control in combination with EASYLAB.

Sensor systems. Type Differential pressure transducer. For the differential pressure recording and control in combination with EASYLAB. X X testregistrierung Sensor systems Type Differential pressure transducer For the differential pressure recording and control in combination with EASYLAB s based on the static measurement principle for

More information

Parr Instrument Company

Parr Instrument Company No. 446M Parr Instrument Company Operating Instruction Manual for 4836 Temperature Controllers TABLE OF CONTENTS Related Instructions...2 Customer Service...2 Preface...3 Scope...3 Applications...3 Electrical

More information

_ ANCHOR LOAD CELLS USER MANUAL

_ ANCHOR LOAD CELLS USER MANUAL _ ANCHOR LOAD CELLS USER MANUAL INDEX IntroduCTION Description PRELIMINARY CHECK InstallaTION TAKING MEASUREMENTS DATA MANAGEMENT Troubleshooting MAINTENANCE Page 4 Page 4 Page 5 Page 6 Page 8 Page 8 Pag.

More information

CANBUS Emulator Mini V1.x. Overview - Installation and Operating Instructions

CANBUS Emulator Mini V1.x. Overview - Installation and Operating Instructions CANBUS Emulator Mini V1.x Overview - Installation and Operating Instructions Contents Overview... 2 Installation... 3 Basic Install... 3 With optional speed sensor input and reverse signal input... 3 Operation...

More information