CAPTROL MODEL 500 MANUAL # R.F. Capacitance Point Level Switch

Size: px
Start display at page:

Download "CAPTROL MODEL 500 MANUAL # R.F. Capacitance Point Level Switch"

Transcription

1 CAPTROL MODEL 500 MANUAL # R.F. Capacitance Point Level Switch 1

2 was started in 1976 to offer new and innovative electronic designs in tank gauging. L&J s new products always used the latest electronics and therefore the company quickly grew. Ten years later L&J bought GPE. Along with GPE, L&J bought, a GPE affiliate that manufactures fittings and valves for the same type of tanks that used the gauging equipment. A short time later, all 3 companies were reorganized under one corporate entity called. In 1994, a brand new, state-of-the-art manufacturing facility was built to bring all of the L&J Technologies manufacturing efforts under one roof. In 1996, L&J bought, a manufacturer of liquid level controls and Hi/Low level switches for the boiler, process, and liquid storage industries. On February 28, 2000, L&J purchased Durlam Associates, (now Durlam Inc.). is located in Houston, Texas and is the leading manufacturer of fiberglass reinforced plastic (FRP) Derakane 470 conservation vents and fittings. On March 31, 2000, L&J purchased Delavan Process Instrumentation in Naugatuck, CT. is a well-established name in ultrasonic, capacitance and microwave point level and continuous level measurement for liquids and solids. Delavan was relocated to L&J Technologies corporate headquarters in Hillside, Illinois. Today, the L&J family of companies is the world s largest manufacturer specializing in the monitoring, management, and control of bulk liquids. L&J provides quality products for the Petroleum, Petrochemical, Chemical, Food, Pharmaceutical, Pipeline, Steel, Water Treatment and Biogas ( ) Industries. Visit L&J Technologies on the internet at 2

3 TABLE OF CONTENTS Page(s) 1.0 Introduction 1.1 Description Principle Of Operation Ordering Information Product Specifications 2.1 Dimensions Third Party Approvals Electrical Specifications Installation 3.1 Unpacking Mounting Location Mounting Instructions Installation Procedure Wiring Procedure Relay Wiring Truth Tables Adjustment Controls 4.1 Component Description Calibration 5.1 Board Layout Equipment/Requirements Calibration Procedure Troubleshooting 6.1 Introduction Electronics Test Green LED Flashes Self Test Probe Test Calibration Application Test Spare Parts Return Goods Policy Repairs Product Warranty

4 1.0 INTRODUCTION The contents in this instruction manual are designed for Delavan's model CAPTROL 500 R. F. Capacitance point level switch. Please review the information contained in this instruction manual carefully to ensure proper operation. 1.1 Description Delavan's CAPTROL model 500 is a microcontroller based on/off R.F. Capacitance single point level switch. It may be used in both powder bulk solids and liquid applications. 1.2 Principle of Operation The CAPTROL model 500 microcontroller based level switch consists of solid state electronics mounted in a cast aluminum explosion proof enclosure and a sensing probe. The CAPTROL 500 responds to a change in the low energy electrical field present on the Active sensing element of the probe, the on-board relay transfers to a field selectable energized or de-energized state. This change is created by the process material level having a greater ground potential as it covers the probe. In electronic terms this is described as capacitance, impedance, or admittance change. ACCUMULATED BUILD-UP on the probe is ignored via Delavan's unique drive guard (shown below). The driven guard produces a force field over the build-up; the ground potential of the build-up is removed leaving only the process level to be detected. The Guard Element should protrude at least one inch into the process beyond the mounting nozzle. Product Build-Up Active Guard Typically, ground referencing the process material is accomplished by threading the probe to a metallic tank. Hence the tank becomes the ground reference for the process material. Non-metallic tanks require a ground reference near the probe for optimum performance. A grounded pipe or plate can serve this purpose. Feel free to review this with Delavan if a vessels ground is in question. The amount of capacitance generated in a given application is dependent upon the dielectric constant of the process material, the distance from the sensing probe to the earth ground, or a ground reference, and by the size (surface area) of the sensing probe. Assuming that the dielectric constant of the process material is consistent, and that the sensing elements mounting location in the vessel is fixed, the amount of capacitance generated is based upon the sensing elements overall size or area. When the process material fluctuates in the vessel, the amount of capacitance generated between the sensing element and the vessel wall or ground also fluctuates. C = Ke x A D CAPACITANCE PLATE DISTANCE CAPACITANCE PLATE Size (area) = in Capacitance Distance = in Capacitance Dielectric = in Capacitance C = Capacitance Ke = Dielectric A = Area D = Distance Force Field Product Build-Up 4

5 1.3 Ordering Information 2.0 PRODUCT SPECIFICATIONS CAPTROL Dimensions STANDARD GT (457.2mm) 9 (228.6mm) 8.25 (209.5mm) Special Features H = High Temperature 12 Lagging Extension (GT, GC, GTH) 90 = 90 Downward Bend on Probe Active Section S = Sensitivity sleeve, 2 or 5 00 = None 3/4 NPT Wrench on these flats only 3/4 NPT Conduit Access both ends 4.5 R Swing (114.3mm) Process Mounting All Flanges Available 00 =None Sensing Probe Type (Specify insertion length) GIMF = Guarded Injection Molded Fortron, 316 GIMN = Guarded Injection Molded Noryl, 316 Stainless Steel, 14 Length GT = Guarded Teflon, 1/4 Center Rod 316 Stainless Steel, 18 Length GT1/2 = Guarded Teflon, 1/2 Center Rod, 316 Stainless Steel, 6 Length GC GFC GTH GTT GAR THD = Guarded Ceramic, High Temp., (750 F max) = GIMN with 316 Stainless Steel Flexible Cable, (25 ft. max) = Guarded Teflon, 1/4 Center Rod, Hastelloy, 36 or Less = Guarded Teflon, Teflon Sealed Active, 18 Length = Guarded Abrasion Resistant Stainless Steel with Durable Plastic Insulator = Non-guarded, Teflon Sealed Active, (Available Bare) 4.5R SWING (114.3 mm) 3/4 Connduit Green Ground Wire w/ring terminals must bond the two enclosures 6.75 (171.5 mm) 3/4 Conduit Access both ends Probe Connection Diestion Length 3/4 NPT Remote Mount Earth Ground 1 150# RF Flange w/1 NPT Thread Electronic Control Options I = Integrated R = Remote Mounted Electronics with 5ft.Cable (50-ft.max) R10 = Includes: 10-ft. cable 1 Mounting Flange, Enclosure 2.2 Third Party Approvals Model 500 R.F. Capacitance Point Level Switch Third Party Agency Approvals CSA Only for probes THD and KHD Class I, Groups C & D Class II, Groups E, F & G, Division 1 & 2 5

6 2.3 Electrical Specifications Electrical Specifications Supply Voltage 115, Hz 24 VDC Power Consumption < 3 VA Sensitivity Adjustable: 0.5 pf to 10 pf Bulk Solids - 8 Ib./cu.ft. & > Liq dielectric constant &> Output Relay, Form C DPDT VAC Non Ind VAC Non Ind VDC Non Ind. Time Delay Adjustable:.1 to 30 seconds Fail-safe Switch selectable - High level or Low level Temperature Range Electronics: (-40 to +71 C) (-40 to +160 C) Enclosure Rating Die Cast Aluminum with fused Polyester paint finish 3.0 INSTALLATION 3.1 Unpacking Remove the CAPTROL 500 carefully from the shipping carton. Check to make certain that no damage has occurred to the electronics or to the sensing probe. If the equipment has been damaged, notify the shipping carrier immediately. 3.2 Mounting Location Meets NEMA 4,5,7,9 & 12 NEC Class I Division II NEC Class II Division II Delavan's CAPTROL model 500 should be installed and mounted in an environment where temperatures are no less than -40 F (-40 C) and no greater than +165 F (+73 C). Normally, when installed in metallic vessels, the vessel wall serves as the ground reference. It is important to the overall operation of the system that a good connection be made between the sensing probe and the vessel. If in doubt, connect a separate ground strapping wire between the CAPTROL 500's housing and the metal vessel. When installed in vessels containing conductive liquids, the location of the probe in relationship to the vessel wall is not critical. When the CAPTROL 500 is used to monitor materials that have low dielectric values (nonconductive materials or materials with a dielectric value < 20) special provisions should be made to locate the sensing probe within 10 inches of the vessel wall. If this cannot be accomplished an artificial ground reference (metal pipe or rod) should be considered. This will enhance the units sensitivity and operation. For applications where the CAPTROL 500 is being used in non-metallic vessels i.e. plastic, fiberglass, or concrete, an artificial ground reference that runs parallel to the sensing probe must be used. Typically, this can be accomplished by mounting a steel plate or steel pipe parallel to the probe. A permanent wire connection from the ground reference to the CAPTROL 500 completes the ground reference. Avoid mounting the ground reference where process material can remain bridged between the active probe element and the ground reference. 3.3 Mounting Instructions Delavan's CAPTROL 500 can be used with both rigid sensing probes and flexible cable style sensing probes. Rigid sensing probes up to 20 inches in length are shipped from the factory pre-assembled to the electronic control unit. Sensing probes over 20 inches in length, as well as, flexible cable style sensing probes, must be assembled in the field Installation Procedure The probe equipped with your CAPTROL 500 is a sealed gland. Do not separate the probe bushing during installation or removal. 1. Insert the entire probe assembly into the vessel and torque using a wrench on the smaller hex bushing. Max. torque: 120 ft/lb. Pipe dope or Teflon tape is recommended. 2. Conduit requirements are 3/4" N.P.T. To prevent accumulation of moisture in the CAPTROL 500 housing, conduits should enter from a lower point of elevation. Note: Avoid mounting in the fill stream. Note: Mount at least 24 inches from other Radio Frequency (R.F) probes that are in the same plane. 6

7 3.4 Wiring Procedure WARNING! DO NOT ATTEMPT TO WIRE THE UNIT WITH LIVE POWER. REMOVE POWER UNTIL CONNECTIONS ARE COMPLETE. Power and relay wiring should comply with NEC (National Electrical Code) standards and specifications. When selecting wire for power and relay connections use a light gauge, 14 to 22 AWG insulated wire. The CAPTROL 500 has a removable "Plug-In" terminal block for wiring convenience. Power Wiring 1. Make certain power is disconnected. 2. Run power wires through conduit. 3. Connect the hot wire to the appropriate terminal, 115 VAC to #2, 230 VAC to #1, or 24 VDC to #4. Connect the common wire to terminal #3 when using 115 or 230 VAC. When using 24 VDC connect the common to #5. Connect an earth ground wire to the housing ground screw. (See wiring terminal below) When a ground reference is required (as described in 3.2), the ground wire can be connected to terminal #5 or to the ground screw in the housing. Wiring Terminal Relay Wiring The relay contacts are form C Dry Contacts. Power must be supplied to the relay contacts, typically, by using a jumper between the power terminal and the common terminal of the relay Relay Wiring Truth Tables Fail-safe relay connections can be determined by the following truth tables. RELAY FUNCTION SWITCH LOW FAIL-SAFE POSITION LEVEL LEVEL IS FAULT COVERS BELOW CONDITION PROBE PROBE GRN LED ON ON FLASHING RED LED ON OFF OFF RELAY ENERGIZED DE-ENERG DE-ENERG RELAY N.C. OPEN CLOSED CLOSED RELAY N.O. CLOSED OPEN OPEN RELAY FUNCTION SWITCH HIGH FAIL-SAFE POSITION LEVEL LEVEL IS FAULT COVERS BELOW CONDITION PROBE PROBE GRN LED ON ON FLASHING RED LED OFF ON OFF RELAY DE-ENERG ENERGIZED DE-ENERG RELAY N.C. CLOSED OPEN CLOSED RELAY N.O. OPEN CLOSED OPEN 4.0 ADJUSTMENT CONTROLS 220V 110V Housing Ground #10-32 Screw Isolated Form C Relay Contacts VAC 110VAC NEUT. Low Vol TS 24VOC N.C. C. N.O. N.C. C. N.O. Normally Closed Common Normally Open Normally Closed Common Normally Open 4.1 Component Description Refer to 5.1 for the location of the components. Relay Status: Red LED: Illuminates when the relay is energized. System Status: Green LED: This LED stays illuminated through entire detection process. Flashing Green LED indicates a fault. (See trouble shooting). Note: Relay remains de-energized during fault detection. 7

8 Cal Button: This push button initializes calibration. When the button is depressed for 2 sec., the probe conditions are stored in memory. This should be performed when the process level is at least 6 inches below the probe. Sensitivity: This single turn potentiometer will adjust the trip point of the electronics for detection of the process material. 0-setting is the highest sensitivity for process materials with a very low ground potential (see calibration) setting is low sensitivity. 5.1 Board Layout CAPTROL 500 ELECTRONICS ASSY INSTRUCTION MANUAL TP1 TP2 RELAY STATUS SYSTEM STATUS TIME-DELAY SENSITIVITY CAL HIGH FAIL SAFE 220VAC 110VAC NEUT LOW VOLTS 24VOC N.C. C. N.O. N.C. C. N.O HOUSING GROUND RELAY FUNCTION LOW FAIL SAFE 5.2 Equipment/Requirements Fail-Safe/Relay Function: Fail-safe high or fail-safe low does not indicate the physical location of the sensor installed in the vessel. The fail-safe switch is a two position switch that determines if the relay is de-energized when the product is above or below the operation point. Time Delay: This single turn potentiometer will delay the relay up to 30 seconds after detection occurs. Delay acts on both presence and absence of the process level. TP1, TP2 Test Points: Test Points TP1 and TP2 can be used in the Calibration - Application Test to diagnose the process variable (High level - Low level). TP1 will read the active measurement signal produced by the probe and the process material. TP2 will read the sensitivity voltage at which the sensitivity pot is set. See section 6.6 for the Calibration - Application Test Procedure 5.0 CALIBRATION Note: For optimum operation and performance this unit requires calibration after installation. Note: Calibrate when the process level is below the probe at least 6 inches. 5.3 Calibration Procedure Determine the fail-safe mode required for your application. The fail-safe switch position determines if the relay is energized when the product is above or below the operating point. Fail-safe High Level probe Low Level probe Relay De-energized When material covers the When material is below the The calibration is initiated by holding the "CAL" button down for at least two seconds. The Green LED will flash rapidly until programming is complete, (approximately 10 seconds). The Green LED should remain illuminated through the entire "No Fault" operation. Sensitivity can be adjusted or re-adjusted at any time. Use the following examples to determine sensitivity for your application. HIGH SENSITIVITY Dry bulk powders from 8 to 15 lb./cu.ft. Non conductive liquids that have a dielectric value of 5 or less. Set sensitivity potentiometer to 0. MEDIUM SENSITIVITY (Typical applications) Dry bulk powders from 15 to 40 lb./cu.ft. Liquids that have a dielectric value greater than 5 and less than 30. Set sensitivity potentiometer to

9 LOW SENSITIVITY Bulk solids with a moisture content of 10% or greater and that have a bulk density of at least 40 lb./cu.ft. Conductive liquids with dielectric values greater than 30. Set sensitivity potentiometer to 50 or greater. Verify operation. Red LED and relay should transfer at the desired detection point. Red LED illuminated = relay energized. If erratic relay operation exists, adjust the time delay potentiometer for appropriate response time. CALIBRATION COMPLETE 6.0 TROUBLESHOOTING ATTENTION: The following procedures will affect the output control circuit. To avoid unintentional machine operations, notify department authorities. CAUTION: Ignition spark hazard. This equipment is not intrinsically safe. If hazardous conditions exist, perform trouble shooting in repair shop or nonhazardous area. 6.1 Introduction The CAPTROL 500 is comprised of two major components: 1. Electronics 2. Probe This section covers three areas: 1. Defective Electronics 2. Defective Probe 3. Calibration - Application Verify the operational truth tables shown in this section: Acknowledge position of the Relay Function switch (High or Low Fail-safe?) Use the appropriate table. RELAY FUNCTION SWITCH LOW FAIL-SAFE POSITION LEVEL LEVEL IS FAULT COVERS BELOW CONDITION PROBE PROBE GRN LED ON ON FLASHING RED LED ON OFF OFF RELAY ENERGIZED DE-ENERG DE-ENERG RELAY N.C. OPEN CLOSED CLOSED RELAY N.O. CLOSED OPEN OPEN RELAY FUNCTION SWITCH HIGH FAIL-SAFE POSITION LEVEL LEVEL IS FAULT COVERS BELOW CONDITION PROBE PROBE GRN LED ON ON FLASHING RED LED OFF ON OFF RELAY DE-ENERG ENERGIZED DE-ENERG RELAY N.C. CLOSED OPEN CLOSED RELAY N.O. OPEN CLOSED OPEN 6.2 Electronics Test: Self diagnostic of the CAPTROL 500 can be observed via system status LED (Green). If the Green LED is illuminated, the output control circuit can be checked by turning the time delay to "0" and sliding the Relay Function Switch back and forth. 6.3 Green LED Flashes: One second flashes indicate: 1. System has lost volatile memory, or 2. System needs calibration. Recalibrate per section 5.3. Two second flashes indicate: 1. Brown out - supply voltage has dropped below operating limits. See specifications in section 2.3. Recalibrate 6.4 Self Test: This test exercises the on-board microcontroller relay and associated latching circuitry. Step 1. Remove power. 9

10 Step 2. Locate points P4 and P5 on the outer edge of the bottom circuit board. (See the Illustration on page 9) Step 3. Insert a jumper across points P4 and P5. Step 4. Set Relay Function switch to the Low Failsafe position. Step 4. Check resistance between the Guard and the Ground. (A reading greater than 10 meg Ohms indicates the probe is operating properly.) ACTIVE CONNECTION GUARD CONNECTION Step 5. Apply power. The relay and Red LED should cycle every five seconds (5 sec. ON, 5 sec. OFF) Step 6. If the electronics do not respond as described, repair or replacement of electronics is required. Step 7. To return to normal operation, remove power, return jumper to P5 only. Return Relay Function switch to the Fail-safe position for your application. The system is now ready for Power and Calibration. 6.5 Probe Test: SELF TEST COMPLETE The probe equipped with the CAPTROL 500 has three steel elements. Each element is insulated from the other. 1. Ground is the bushing which provides the process connection. 2. Guard is the shorter probe element connected to the electronics by a quick disconnect lug. 3. Active is the center rod, longest element connected to the electronics by a banana connector. Step 1. Remove Power Step 2. Unplug the quick disconnect from the guard and the banana plug from the Active probe element. Step 3. Connect an Ohm meter to the Guard and the Active elements of the probe. Polarity does not matter. A non-covered, or a probe in non-conductive material should have a resistance reading greater than 10 meg Ohms. PROBE TEST COMPLETE 6.6 Calibration - Application Test TP1, TP2 Test Points: To diagnose the process variable (High level - Low level). Connect a DC Voltmeter to Terminal #5 (-) and (+) to the appropriate test point. A positive 0 to 5 VDC signal should be present. TP1 will read the active measurement signal produced by the probe and the process material. The voltage will increase in the positive direction as the process level covers the probe. The voltage will stabilize once the probe is fully covered. This voltage change is referred to as "differential". The illustration on page 10 is an example of an ideal calibration. TP2 will read the sensitivity voltage at which the sensitivity pot is set. TP2 voltage should be 50% of the differential voltage (mid-point) for ideal sensitivity setting. Step 1. To check calibration connect a DC voltmeter(0 to 5V) positive to TP1 and negative to terminal #5. Step 2. Record the voltage when the process level is below the probe. (XXX Volts) Step 3. Push the CAL button. Hold down until the Green LED flashes. 10

11 Step 4. When flashing stops TP1 voltage should be 0 volts. Record voltage (TP1 CAL XXX Volts). Step 5. Read TP1 when the process level covers the probe. Record (TP1 MAX XXX Volts). Step 6. Move positive lead to TP2. The ideal voltage should be in the center of the TP1 CAL and TP1 MAX or (TP1 MAX - TP1 CAL) 2 = TP2. Step 7. To correct TP2 voltage adjust sensitivity potentiometer accordingly to achieve ideal TP2. Step 8. This should render a dependable detection. TEST POINT VOLTAGES (EXAMPLE) 8.0 RETURN GOODS PROGRAM When returning equipment to Delavan, it is necessary to first obtain a return goods authorization (RG) number. In order for Delavan to provide the most efficient service regarding any equipment being returned, the following information is necessary: 1) Billing & shipping addresses 2) Contact name & phone number 3) Reason for return 4) Purchase order number (for repairs) 5) Brief, but detailed, description of problem or reason for return Authorization may be obtained by contacting either Delavan or your local Delavan representative. 9.0 REPAIRS PROCESS LEVEL BELOW PROBE PROCESS LEVEL COVERS PROBE 0V V TP1 min. TP1 max DIFFERENTIAL VOLTAGE TP2 ALARM POINT ADJUST SENSITIVITY POT TO ACHIEVE 50% OF DIFFERENTIAL VOLTAGE AT TP2 CALIBRATION APPLICATION TEST COMPLETE 7.0 SPARE PARTS DESCRIPTION PART NUMBER 500 Final Assembly Electronic Assembly Enclosure Enclosure Lid Enclosure Base GIMN Probe GIMF Probe GT Probe Instruction Manual Delavan equipment returned for repairs will be repaired or replaced at Delavan's discretion to provide optimum performance. The repair item warranty will be the remainder of the original warranty or 90 days, which ever is greater. A flat rate charge applies to repairs out of warranty. This flat rate repair charge also applies to non-warranty items receiving evaluation only. Items with a list price equal to or less than the flat rate repair charge will be replaced and charged accordingly. The customer will be directed to buy a new or re-manufactured replacement for items that cannot be repaired PRODUCT WARRANTY Delavan level control products will be replaced, put in good operating condition, or the purchase price refunded, at the option of Delavan, free of charges except transportation, if defective in their manufacture, labeling, packaging, or shipping, and if notice of said defect is received by Delavan within one year from the date of shipment. The cost of such replacement repair or refund or purchase price shall be the exclusive remedy for any breach of any warranty, and Delavan shall not be liable to any person for consequential damages for injury or commercial loss resulting from any breach of any warranty, of fitness for a particular purpose, and makes no other warranty, express or implied, including implied warranty arising from course of dealing or usage or trade. 11

12 REACHING NEW LEVELS IN PROCESS MEASUREMENT 5911 Butterfield Rd. Hillside, IL PH: (708) FAX: (708)

CAP ANALOG 4100 INSTALLATION & OPERATION MANAUL

CAP ANALOG 4100 INSTALLATION & OPERATION MANAUL CAP ANALOG 4100 INSTALLATION & OPERATION MANAUL An L&J Technologies Co. 5911 Butterfield Road Hillside, IL 60162 Phone: 708-236-6000 Fax: 708-236-6006 1 was started in 1976 by a young engineer who had

More information

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT INSTALLATION AND WIRING INSTRUCTIONS MANUAL 8030 MANUAL PART NUMBER JANUARY 2011. 4304 MATTOX RD. KANSAS CITY, MO 64150 TABLE OF CONTENTS

More information

RF Point Level Control with Sensor Monitor

RF Point Level Control with Sensor Monitor The 681 Point Level Control utilizes DPDT relays to provide switching for peripheral devices (such as pumps) in level applications. A sensor attached to the control acts as an antenna to transmit the process

More information

VRF II Series SURPASSING SENSITIVITY FOR THE TOUGHEST APPLICATIONS FEATURES AND BENEFITS STANDARD VS. ADVANCED UNITS

VRF II Series SURPASSING SENSITIVITY FOR THE TOUGHEST APPLICATIONS FEATURES AND BENEFITS STANDARD VS. ADVANCED UNITS VRF II Series SURPASSING SENSITIVITY FOR THE TOUGHEST APPLICATIONS The VRF II Series uses radio frequency to detect the presence or absence of material in a vessel. It compensates for the load of the probe

More information

PRO REMOTE Series CAPACITANCE PROBE

PRO REMOTE Series CAPACITANCE PROBE Price $5.00 PRO REMOTE Series CAPACITANCE PROBE OPERATING INSTRUCTIONS READ THOROUGHLY BEFORE INSTALLING EQUIPMENT TABLE OF CONTENTS GENERAL SPECIFICATIONS...3 1.0 INTRODUCTION...4 2.0 APPLICATIONS...4

More information

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004 U00X ULTRASONIC LEVEL SWITCH INSTALLATION AND OPERATIONS MANUAL Ultrasonic Liquid Level Switches For Non-Hazardous Locations For Models: U002, U003 & U004 READ THIS MANUAL PRIOR TO INSTALLATION This manual

More information

Level Devices. Rotary Level Indicators Roto-Bin-Dicator

Level Devices. Rotary Level Indicators Roto-Bin-Dicator 7901 NW 107th Terrace Level Devices We offer Rotary Level Indicators, Radio Frequency Level Indicators, and Turning Fork Level Sensors. For more information please contact your Schenck Process Aftermarket

More information

Installation and Operating Manual

Installation and Operating Manual Model u002 & u003 Installation and Operating Manual Ultrasonic Level Switch 60 Great Hill Road Naugatuck, CT 06770 ph: 203-729-6434 fax: 203-729-6696 www.innovativesensing.com Read this Manual Before Installing

More information

KENCO ENGINEERING COMPANY

KENCO ENGINEERING COMPANY KENCO ENGINEERING COMPANY P.O. BOX 470426 TULSA, OK 74147-0426 PHONE: (918) 663-4406 FAX: (918) 663-4480 www.kenco-eng.com e-mail: info@kenco-eng.com SERIES KTD THERMAL DIFFERENTIAL FLOW/LEVEL SWITCH INSTALLATION

More information

PROCAP Capacitance Level Sensors

PROCAP Capacitance Level Sensors PROCAP Capacitance Level Sensors Simple. Rugged. Reliable. Triple thread screw on/off cover - No more bolts! Unsurpassed sensitivity and stability No interference from RF signals Switch selectable high/low

More information

PROCAP Capacitance Level Sensors

PROCAP Capacitance Level Sensors PROCAP Capacitance Simple. Rugged. Reliable. Triple thread screw on/off cover - No more bolts! Unsurpassed sensitivity and stability No interference from RF signals Switch selectable high/low fail-safe

More information

R F C a p a c i t a n c e TrueCap

R F C a p a c i t a n c e TrueCap TrueCap RF Capacitance Point Level Sensors Extensive Product Line for Bulk Solid Applications Superior Sensitivity of 0.5pF is Standard Maximum Reliability and Calibration Stability Automatic Material

More information

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004 U00X ULTRASONIC LEVEL SWITCH INSTALLATION AND OPERATIONS MANUAL Ultrasonic Liquid Level Switches For Non-Hazardous Locations For Models: U002, U003 & U004 READ THIS MANUAL PRIOR TO INSTALLATION This manual

More information

PRO REMOTE 25 LV CAPACITANCE PROBE

PRO REMOTE 25 LV CAPACITANCE PROBE Price $5.00 PRO REMOTE 25 LV CAPACITANCE PROBE OPERATING INSTRUCTIONS READ THOROUGHLY BEFORE INSTALLING EQUIPMENT Distribué par : 2 rue René Laennec 51500 Taissy France Fax: 03 26 85 19 08, Tel : 03 26

More information

ROTARY Point Level Measurement for Inventory Control

ROTARY Point Level Measurement for Inventory Control Measure. Detect. Alert. ROTARY Point Level Measurement for Inventory Control Detect high and low levels while protecting valuable inventory with tried-and-true rotary level indicators from BinMaster. Made

More information

LTX RF LEVEL SENSOR. Instruction Manual

LTX RF LEVEL SENSOR. Instruction Manual LTX RF LEVEL SENSOR Instruction Manual FOR MODELS LTX01, LTX02, LTX05 Intempco Document No: LTX - M01 Rev. 1 Issue Date: April 2005 LTX01 RF LEVEL SENSOR USER MANUAL Software Rev : Rev. Date : June 2004

More information

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION MODEL: PS600 HZ: 60 A model ps600 installation and service manual for federal model ps600 FEDERAL SIGNAL CORPORATION POWER SUPPLY VOLTS: SERIES: 120VAC FEDERAL SIGNAL CORPORATION UNIVERSITY PARK, IL. U.S.A.

More information

IOM. LP-100 & LP-200 Pulse Point TM Installation & Operation Manual

IOM. LP-100 & LP-200 Pulse Point TM Installation & Operation Manual IOM LP-100 & LP-200 Pulse Point TM Installation & Operation Manual CAUTION It is essential that all instructions in this manual be followed precisely to ensure proper operation of the equipment. SAFETY

More information

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company Manufacturer of Dimensions Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com OWNERS MANUAL April

More information

TrueCap RF Capacitance Level Sensor

TrueCap RF Capacitance Level Sensor BULLETIN 464A INSTALLATION & OPERATION TrueCap RF Capacitance Level Sensor Model MK-2e Model MK-2e Thank you for purchasing a quality product manufactured by Monitor Technologies LLC. We realize that you

More information

T21 Thermal Differential Switch

T21 Thermal Differential Switch T21 Thermal Differential Switch General Instructions The T21 Point Level Switch is a state-of-the-art in liquid level and interface measurement and control. Level detection is accomplished by using a high-resolution

More information

Super-Safe-Plus Roto-Bin-Dicator

Super-Safe-Plus Roto-Bin-Dicator Super-Safe-Plus Roto-Bin-Dicator for your most demanding applications... Offers both mechanical and electronic sensing in one reliable Point Level Sensor... Level control with added confidence Under normal

More information

RP-4000 Reserve Power Control

RP-4000 Reserve Power Control Instruction Manual IM-0580 RP-4000 Reserve Power Control Table of Contents General Information... 2-3 Introduction... 2 Cautions... 2 Receiving/Inspection... 2 Storage... 2 Equipment Return... 2 Identification

More information

MIL-24/2600Q MIL-24/3200DQ

MIL-24/2600Q MIL-24/3200DQ Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121473B OWNER'S

More information

MAXIGARD A2000 SPEED SWITCH. Introduction

MAXIGARD A2000 SPEED SWITCH. Introduction A107-05, Page 1 952-361-3026, INC. (Fax) 952-368-4129 327 LAKE HAZELTINE DRIVE, CHASKA, MN 55318 800-328-0738 MAXIGARD A2000 SPEED SWITCH Introduction The Maxigard A2000 Speed Switch is designed to monitor

More information

8460SRC Replacement Chassis for Scully ST-6 and Biclops Monitors

8460SRC Replacement Chassis for Scully ST-6 and Biclops Monitors 8460SRC Replacement Chassis for Manual Part Number: OPTI-THERM is a registered trademark of CIVACON, A Dover Company QUICK-START is a registered trademark of CIVACON, A Dover Company Biclops is a registered

More information

Model 550 Series Vibration Switches

Model 550 Series Vibration Switches OPERATION MANUAL Vibration Switches Includes: 550 550M 550-X 550M-X Page 2 SECTION TITLE PAGE 1. INTRODUCTION... 2 2. FEATURES... 3 3. WIRING... 4 4. ANALOG METER... 4 5. TESTING... 4 6. INSTALLATION...

More information

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com

More information

INSTALLATION MANUAL ACL 5500 COMBUSTION SAFETY CONTROLLER

INSTALLATION MANUAL ACL 5500 COMBUSTION SAFETY CONTROLLER 5500 COMBUSTION SAFETY CONTROL INSTALLATION MANUAL FOR 5500 COMBUSTION SAFETY CONTROLLER WARNING This manual must be read in its entirety before installation of this controller. Installation must be performed

More information

Transfer Switch TS-50. Owner s Manual

Transfer Switch TS-50. Owner s Manual Transfer Switch TS-50 Owner s Manual Table of Contents Introduction 2 Installation 2 Operational Testing 7 Troubleshooting 7 Hi-Pot Testing 8 Generator Note 9 Medical Appliances 10 Caution 10 Disclaimer

More information

SPC-PANEL Simplex, Single Phase Pump Control Panel

SPC-PANEL Simplex, Single Phase Pump Control Panel Pump Installation and Service Manual SPC-PANEL Simplex, Single Phase Pump Control Panel Pump Controls for 2 HP Grinder Pumps NOTE! To the installer: Please make sure you provide this manual to the owner

More information

Analog Condensate Monitor Instruction & Maintenance Manual

Analog Condensate Monitor Instruction & Maintenance Manual Analog Condensate Monitor Instruction & Maintenance Manual Advantage Controls, Inc. PO Box 1472 Muskogee, OK 64402 Phone: 800-743-7431 Fax: 888-686-6212 www.advantagecontrols.com EE-13 email: aci@advantagecontrols.com

More information

DC to AC Power Inverters

DC to AC Power Inverters Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com ISO 9001:2000 Certified

More information

DC to AC Power Inverters

DC to AC Power Inverters Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121114C OWNERS

More information

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY OPERATING INSTRUCTIONS PLEASE READ CAREFULLY 925-0330 Rev 0 0416 TABLE OF CONTENTS SAFETY SUMMARY... 3 SPECIFICATIONS... 4 1.0 INTRODUCTION/DESCRIPTION.... 5 2.0 LOCATION AND MOUNTING... 5 3.0 CONNECTIONS

More information

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz. 103158 March 9, 2011 FOR INDOOR USE ONLY Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045 (830)629-2900 / 1-800-729-3839 / Fax (830)620-6711 E-MAIL: detex@detex.com INTERNET: www.detex.com

More information

OWNERS MANUAL JANUARY 2007 ISO

OWNERS MANUAL JANUARY 2007 ISO Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121231B OWNERS

More information

DIAMOND POINT VIBRATING PROBES

DIAMOND POINT VIBRATING PROBES DIAMOND POINT VIBRATING PROBES DP130 DP120 DP140 DP150 Instruction Manual Third revision, April 2016 Hycontrol Ltd., Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, U.K. Tel: + 44 (0)1527

More information

ITS-50R TRANSFER SWITCH OWNER S MANUAL

ITS-50R TRANSFER SWITCH OWNER S MANUAL ITS-50R OWNER S MANUAL IOTA Engineering Transfer Switches provide automatic power switching between two or three separate 120/240 volt AC input sources, including powercords, onboard generators, onboard

More information

GCU-10. Automatic Engine Control Unit Operators Manual

GCU-10. Automatic Engine Control Unit Operators Manual GCU-10 Automatic Engine Control Unit Operators Manual KUTAI ELECTRONICS INDUSTRY CO., LTD. TEL : +886-7-8121771 FAX : +886-7-8121775 Website : www.kutai.com.tw Headquarters : No.3, Lane 201, Chien Fu St.,

More information

ADI-125/750 ADI-125/1500 ADI-125/2500

ADI-125/750 ADI-125/1500 ADI-125/2500 Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121094B OWNERS

More information

WF-5110R True Sine Wave Inverter

WF-5110R True Sine Wave Inverter Operator s Manual WF-5110R True Sine Wave Inverter WF-9900 Series WF-5110R ( The Inverter model number is located on the label on top of the enclosure) Distributed in the U.S.A. and Canada by ARTERRA DISTRIBUTION

More information

Instruction Manual Princo Model L3545

Instruction Manual Princo Model L3545 Instrumentation designed with the user in mind Instruction Manual Princo Model L3545 Remotely Adjustable Presence/ Absence Detector with NULL-KOTE Rev 2, 25 July 08 PRINCO INSTRUMENTS INC., 1020 INDUSTRIAL

More information

Application Engineering

Application Engineering Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor

More information

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 120015D OWNERS

More information

Installation, Operation & Maintenance Instructions

Installation, Operation & Maintenance Instructions Installation, Operation & Maintenance Instructions Model RH/RHX Rotary Paddle Bin Level Indicator Thank you for purchasing the Model RH/RHX Rotary Paddle Bin Level Indicator from BlueLevel Technologies.

More information

Z4-Series DREXELBROOK DATA SHEET. Easy-Installation. Z-tron IV Point Level Switch, a reliable low-cost, on/off level switch.

Z4-Series DREXELBROOK DATA SHEET. Easy-Installation. Z-tron IV Point Level Switch, a reliable low-cost, on/off level switch. DREXELBROOK DATA SHEET Easy-Installation One-piece unit is easily installed through a single 3/4-inch, probe dependent vessel opening. Calibration is quick and simple. Z-tron IV Point Level Switch, a reliable

More information

BMRX Series ROTARY LEVEL CONTROL

BMRX Series ROTARY LEVEL CONTROL BMRX Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY 925-0292 Rev C TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY... 4 1.0 INTRODUCTION... 5 2.0 INSTALLATION...

More information

BMRX Series Rotary Level Indicator

BMRX Series Rotary Level Indicator BMRX Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE READ

More information

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service Installation Instructions VA-908x Code No. LIT-12011566 Issued August 24, 2009 Applications The VA-908x Series Electric

More information

CAPACITANCE LEVEL SWITCH

CAPACITANCE LEVEL SWITCH CAPACITANCE LEVEL SWITCH http: //www.fine-tek.com e-mail: info@fine-tek.com Tel: 886--696789 Fax: 886--68668 4 PRINCIPLE The capacitance level switch measuring principle is based on the "capacitance effects".

More information

OWNERS MANUAL JANUARY 2007 ISO

OWNERS MANUAL JANUARY 2007 ISO Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com OWNERS MANUAL JANUARY

More information

TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY INTRODUCTION INSTALLATION Location and Mounting Input

TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY INTRODUCTION INSTALLATION Location and Mounting Input BMRX Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY... 4 1.0 INTRODUCTION... 5 2.0 INSTALLATION...5 2.1 Location and

More information

II DISTRIBUTION & SUBSTATION TYPE C

II DISTRIBUTION & SUBSTATION TYPE C CapCheckIII DISTRIBUTION & SUBSTATION TYPE Ca p a c i t o r C h e c ke r Operating & Instruction Manual 1475 Lakeside Drive Waukegan, Illinois 60085 U.S.A. 847.473.4980 f a x 8 4 7. 4 7 3. 4 9 8 1 w e

More information

Pump Installation and Service Manual HRS Hydromatic Retractable System

Pump Installation and Service Manual HRS Hydromatic Retractable System Pump Installation and Service Manual HRS Hydromatic Retractable System NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party

More information

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control SERVICE UNIT INFORMATION SUPPLEMENT HP21 Corp. 9426 L10 Litho U.S.A. All HP21-4 and -5 units (single and three phase) are equipped with a TSC6 two-speed control. The TSC6 (A14) two-speed control contains

More information

Model 930 Power Control System Instruction Manual

Model 930 Power Control System Instruction Manual Model 930 Power Control System Instruction Manual Publication No. A105328-001 Rev A December 2000 Another quality product from: 7128 Shady Oak Rd, Eden Prairie MN 55344 Phone: (952) 949-9009 Fax: (952)

More information

HYGRODYNAMICS DIGITAL DEW POINT MONITOR PC BOARD MODEL 6392N & 6392N2 TABLE OF CONTENTS

HYGRODYNAMICS DIGITAL DEW POINT MONITOR PC BOARD MODEL 6392N & 6392N2 TABLE OF CONTENTS HYGRODYNAMICS DIGITAL DEW POINT MONITOR PC BOARD MODEL 6392N & 6392N2 TABLE OF CONTENTS INTRODUCTION... 2 SPECIFICATIONS... 2 INSTALLATION... 3 PC Board Mounting...3 Sensor Installation...3 Manifold Assembly...4

More information

Installation and Operating Instructions

Installation and Operating Instructions Installation and Operating Instructions Series AVI-PSM SMART RF DRIVEN SHIELD LEVEL SWITCH General Safety Notes CAUTION: DO NOT USE ADOPT MONO-COMPOSITION ENCAPSULAN (acetic acid will decay electrical

More information

RS85 Vibrating fork level switch

RS85 Vibrating fork level switch Data sheet DS/-EN Rev. P Multi-option liquid level switch K-TEK Level products Measurement made easy Features Direct replacement for ultrasonic Gap switches, RF capacitance switches, float switches and

More information

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual DIN Rail UPS Model: DIN-UPS 24-10 Installation/Operation Manual Table of Contents Section Page Section Page Quick Start 2 1) General Information 4 Materials Provided 4 Optional Equipment 4 2) Safety Information

More information

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS 24-10 Installation/Operation Manual Table of Contents Section Page Section Page Quick Start 2 1) General Information 4 Materials Provided

More information

For Hazardous Locations

For Hazardous Locations L500E LIQUID LEVEL FLOAT SWITCH INSTALLATION AND OPERATIONS MANUAL Single or Multi-Point, Vertically-Mounted Liquid Level Float Switch For Hazardous Locations READ THIS MANUAL PRIOR TO INSTALLATION This

More information

Battery Control Center - Diesel

Battery Control Center - Diesel Service Manual CAUTION: All servicing of the Battery Control Center should be done only by a qualified Service Technician. Inadvertent shorts inside the Battery Control Center could result in severe damage

More information

INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE ACTUATOR MANIFOLD

INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE ACTUATOR MANIFOLD INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE B-3724M ACTUATOR MANIFOLD MIDLAND MANUFACTURING CORP. 7733 Gross Point Road Skokie, Illinois 60077 Phone (847) 677-0333 FAX (847) 677-0138 WEBSITE

More information

Airpax Dimensions, Inc.

Airpax Dimensions, Inc. Airpax Dimensions, Inc. 4467 White Bear Parkway (651) 653-7000 St. Paul, MN 55110-7626 Fax (651) 653-7600 121177B OWNERS MANUAL JANUARY 2007 Airpax Dimensions, Inc. Uninterruptible Power System OWNERS

More information

PROFIRE 1100i IGNITION FLAME SAFETY CONTROLLER

PROFIRE 1100i IGNITION FLAME SAFETY CONTROLLER PROFIRE 1100i IGNITION FLAME SAFETY CONTROLLER Cautions WARNING: EXPLOSION HAZARD- -DO NOT SERVICE UNLESS AREA IS KNOWN TO BE NON- HAZARDOUS -DO NOT OPEN WHEN ENERGIZED EXPLOSION HAZARD- -SUBSTITUTION

More information

PM500. Voltage Regulator User Manual. A Regal Brand. Scan here for other languages.

PM500. Voltage Regulator User Manual. A Regal Brand. Scan here for other languages. PM500 Voltage Regulator User Manual A Regal Brand Scan here for other languages. Introduction The PM500 is an encapsulated electronic voltage regulator intended for use with Marathon Generators PMG system.

More information

S003 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted, Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

S003 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted, Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL S003 LIQUID LEVEL FLOAT SWITCH INSTALLATION AND OPERATIONS MANUAL Single or Multi-Point, Vertically-Mounted, Liquid Level Float Switch READ THIS MANUAL PRIOR TO INSTALLATION This manual provides information

More information

Sierra 80 Volt Brushless DC Motor Controller Product Specification

Sierra 80 Volt Brushless DC Motor Controller Product Specification Sierra 80 Volt Brushless DC Motor Controller Product Specification Assembly 025F0139 600A0620 Rev. A December 2, 2008 025F0139 Brushless DC Motor Controller Page 1 Revision History EC # Date Rev Description

More information

Bin-Dicator FEATURES AND BENEFITS

Bin-Dicator FEATURES AND BENEFITS Bin-Dicator DESCRIPTION The original electromechanical point level switch, Bin-Dicator diaphragm-type level controls were the first to enjoy general usage in the industry. Bin-Dicator controls eliminate

More information

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

User Manual. T6 Tachometer. Online:   Telephone: P.O. Box St. Petersburg, Florida 33736 User Manual T6 Tachometer Online: www.phareselectronics.com Telephone: 727-623-0894 P.O. Box 67251 St. Petersburg, Florida 33736 Table of Contents Overview... 1 Description... 1 Wiring... 1 T6 Tachometer

More information

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase. PD9100 / 9200 SERIES POWER CONVERTER OWNERS MANUAL PROGRESSIVE DYNAMICS, INC. POWER CONVERTER LIMITED WARRANTY I. LIMITED WARRANTY: Progressive Dynamics, Inc. warrants its power converter to be free from

More information

Standard Specifications

Standard Specifications Custom Hangar Door Edges About Sensing Edges... The Hangar Door Sensing Edge is a pressure sensitive electric edge which is custom manufactured to your exact specifications for length, width, height and

More information

Transfer Switch GPTS 30

Transfer Switch GPTS 30 Transfer Switch GPTS 30 Owner s Manual Table of Contents Introduction 2 Installation 3 Operational Testing 7 Troubleshooting 8 Hi-Pot Testing 9 Generator Note 10 Medical Appliances 10 Caution 10 Warranty

More information

Installing Power Components

Installing Power Components This chapter provides instructions on how to install and reinstall power components in the Cisco NCS 4016 chassis. It also covers connecting and disconnecting power and powering on the chassis. The Cisco

More information

Industrial Fluid Controls

Industrial Fluid Controls UFACTURING QUALITY SERVICE MANUFACTURING QUALITY SERVICE MANUFACTURING QUALITY SERVICE MANUFACTU Industrial Fluid Controls Manufacturers of liquid level controls for overfill protection Customer Service:

More information

CVR-625. Compact Vibrating Rod Instruction Manual

CVR-625. Compact Vibrating Rod Instruction Manual CVR-625 Compact Vibrating Rod Instruction Manual BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS

More information

Operations Manual. Zero Speed Switch Sensor Model ZS09P

Operations Manual. Zero Speed Switch Sensor Model ZS09P Zero Speed Switch Sensor Model ZS09P The must be referred to for correct installation. Failure to comply with the shall void all warranties and liabilities. Overview The Phares Electronics Model ZS09P

More information

MAGNAMAX DVR DIGITAL VOLTAGE REGULATOR

MAGNAMAX DVR DIGITAL VOLTAGE REGULATOR MAGNAMAX DVR DIGITAL VOLTAGE REGULATOR TECHNICAL MANUAL MODEL DVR 2000 AND DVR 2000C FIGURE 1 - FRONT AND REAR VIEW OF VOLTAGE REGULATOR...4 SECTION 1- INTRODUCTION...5 GENERAL DESCRIPTION...5 SPECIFICATIONS...5

More information

P200 P/I Transducer. Installation, Operation, and Maintenance Instructions INTRODUCTION

P200 P/I Transducer. Installation, Operation, and Maintenance Instructions INTRODUCTION INTRODUCTION Scope This manual provides instructions for the installation, adjustment, maintenance, and parts ordering of the P200 Pneumatic-to-Current P/I Transducer. Due to its over-engineered design,

More information

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure S T C TM To Order, Please Specify: 1) Model No., 2) Voltage 2 Way, NC Pilot Piston Stainless Steel Part No. Voltage

More information

FAIRCHILD T5200 SERIES ELECTRO-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

FAIRCHILD T5200 SERIES ELECTRO-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions FAIRCHILD T500 SERIES ELECTRO-PNEUMATIC TRADUCER Installation, Operation and Maintenance Instructions Identification Number Underwriting Group Factory Mutual Canadian Standard T (F) (C) 500- Approval Class

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview. Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

Echotel Trident 91S/92S Ultrasonic Level Switches

Echotel Trident 91S/92S Ultrasonic Level Switches Echotel Trident 91S/92S Ultrasonic Level Switches Instruction Manual and Parts List 91S PART NUMBER CONSTRUCTION cont. Model 91S 91S PART NUMBER CONSTRUCTION Model 92S MODEL IDENTIFICATION Each unit has

More information

SERIES VAC Microprocessor Based Direct Spark Ignition Control FEATURES DESCRIPTION APPLICATIONS THE TOTAL SOLUTION FOR GAS IGNITION CONTROL

SERIES VAC Microprocessor Based Direct Spark Ignition Control FEATURES DESCRIPTION APPLICATIONS THE TOTAL SOLUTION FOR GAS IGNITION CONTROL SERIES 35-72 120 VAC Microprocessor Based Direct Spark Ignition Control 35.72.03 FEATURES Two Mounting Configurations Open Board With Stand-Off's - saves space and cost Potted - protection for washdown

More information

UV DISINFECTION UNIT MODEL 3G

UV DISINFECTION UNIT MODEL 3G SALCOR INC. P. O. Box 1090 Fallbrook, CA 92088-1090 Telephone: (760) 731-0745 Fax: (760) 731-2405 INSTALLATION MANUAL UV DISINFECTION UNIT MODEL 3G February, 2011 I. INSTALLATION INSTRUCTIONS WARNING!

More information

MODEL MSD MOTION CONTROL INSTALLATION AND OPERATION

MODEL MSD MOTION CONTROL INSTALLATION AND OPERATION CONVEYOR COMPONENTS COMPANY 130 Seltzer Road, PO Box 167 Croswell, MI 48422 USA PHONE: (810) 679-4211 TOLL FREE (800) 233-3233 FAX: (810) 679-4510 Email: info@conveyorcomponents.com http://www.conveyorcomponents.com

More information

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE USER MANUAL IMI vibration switch INSTALLATION - OPERATION - MAINTENANCE Z0929039_A ISSUED 03/2017 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. contents Overview General

More information

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual Manual No. 5AOP-OM1-2 Val-Matic Air / Oil Hydraulic Panel Pump Control System Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION...

More information

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC. INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL INS120P TASCO, INC. THIS TESTER IS DESIGNED FOR USE ONLY BY QUALIFIED ELECTRICIANS. IMPORTANT SAFETY WARNINGS mwarning Read and understand this material

More information

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited. SERVICE MANUAL ELECTRIC BRAISING PANS (30 & 40 GALLON) VE30 VE40 ML-126849 ML-126850 VE40 SHOWN - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used

More information

TC26-B Vehicle Sensor

TC26-B Vehicle Sensor Section 1 General Description The Model TC26-B is a microprocessor controlled vehicle sensor with a variable range. It is designed to trigger the operation of a traffic controller. The TC26-B will only

More information

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual COMPANY Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual 2016 AW-Lake Company. All rights reserved. Doc ID:PADDLEMAN082416 Mechanical Specifications Flow Meter with Polypropylene

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction K Pressure Controller Cataloge Code Characteristics Index K00-2 Pressure Controller Brief Introduction KC32 Screw Tube Differential Pressure Controller K01 KY10 Bellows Type Differential Pressure Controller

More information

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY GC-1 Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY GENERAL INFORMATION The GC-1 heating cable controller has been designed and manufactured for

More information

L500 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

L500 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL L500 LIQUID LEVEL FLOAT SWITCH INSTALLATION AND OPERATIONS MANUAL Single or Multi-Point, Vertically-Mounted Liquid Level Float Switch READ THIS MANUAL PRIOR TO INSTALLATION This manual provides information

More information

Level limit switch Series RF 3000 Selection list

Level limit switch Series RF 3000 Selection list Table of content Page Overview P2 Applications P4 ------------------------------------------------------------------------------------------------------------- RF 3100 Standard version P6 -------------------------------------------------------------------------------------------------------------

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split-System Air Conditioners YD360/480/600, YJ-30/-40/-50 and J30/40/50 YD Models 642546-UAI-A-080 GENERAL Standard operation

More information