Operator's Manual Tracer III Nerve Locator, Model NL-3
|
|
- Rolf Roberts
- 5 years ago
- Views:
Transcription
1 Operator's Manual Tracer III Nerve Locator, Model NL , Life-Tech, Inc. All rights reserved. M1043 Rev C
2
3 IMPORTANT! - IN THIS MANUAL WARNING STATEMENTS: Indicate information or procedures that, if not followed correctly, could cause injury to personnel, and serious injury or death to the patient. CAUTIONS: Indicate information or procedures that, if not followed correctly, could cause improper results or damage to the equipment. Manufactured by: 4235 Greenbriar Dr. Stafford, TX Administrative / Financial Fax: Sales / Customer Service Fax: Technical and Clinical Support Fax: Made in USA Caution: Federal (USA) law restricts this device to sale by or on the order of a physician.
4 Table of Contents SECTION DESCRIPTION PAGE 1. PRECAUTIONS GENERAL DESCRIPTION AND SPECIFICATIONS TRACER III DISPLAY, CONTROLS AND INPUTS ASSEMBLY OPERATING PROCEDURES MAINTENANCE Battery Replacement Cleaning and Disinfection Required Service LIMITED WARRANTY Table of Figures SECTION DESCRIPTION PAGE 3.1 DISPLAY, CONTROLS AND INPUTS TRACER III LCD PROTECTIVE BOOT (PB) PROTECTIVE BOOT WITH MOUNTING BRACKET (MB-5) CONNECTIONS BATTERY REPLACEMENT... 12
5 SECTION 1 PRECAUTIONS Warnings: 1. Explosive Atmospheres: Use of the Tracer III in a flammable or explosive atmosphere may result in death or serious injury from accidental explosion or fire. 2. Microshock Hazard: In patients with pacemakers or cardiac abnormalities, the physician in charge must approve the use of the Tracer III as electrical impulses could interfere with the pacemaker or result in cardiac arrhythmia. Caution: 1. Neuromuscular Disease: Patients with symptoms of myasthenia gravis, Bell's palsy, muscle weakness, or paralysis may not respond normally to nerve stimulation. 2. Servicing: The user should not attempt to service the unit beyond that described in the Operator's Manual. All other servicing should be referred to qualified service personnel. 3. Disconnection of Foot Control: Take care to insure that the foot control is NOT disconnected from the unit when it is ON and connected to the patient. Should this occur, the stimulus output will default to the Stimulus Control Knob setting. Environment/Placement: 1. Foreign Material: Tracer III is designed to be drip resistant, in its normal orientation. Protect this instrument from immersion, spills, the impact of falling objects, and exposure to excessive smoke, dust, mechanical vibration, or shock. 2. Electromagnetic Fields: Do not use the Tracer III in close proximity to equipment that produces strong electromagnetic fields (i.e., MRI, radio frequency cautery equipment, microwave equipment and cellular or cordless phones). 3. Stacking: Do not place any heavy objects on top of the instrument. 4. Heat: Situate the unit away from heat sources such as radiators and warming lamps as exposure to high temperatures may affect operation or cause damage.see Section 2, Specifications for temperature recommendations. 5. Battery Leakage: If the unit is going to be stored for a prolonged period of time, we recommend that you remove the battery to protect the unit from damage caused by battery chemical leakage. 6. Sterilization: Do not sterilize the Tracer III or foot control. 1
6 SECTION 2 GENERAL DESCRIPTION AND SPECIFICATIONS 1. Introduction The Model NL-3 Tracer III is a battery powered nerve locator for regional nerve block procedures. It is classified as a class II medical device by the FDA and according to Council Directive 93/42/EEC. The unit generates constant-current 50, 100, 300, 500 or 1000 microsecond pulses at a rate of 1Hz or 2Hz. Pulse delivery is indicated by the LCD Output Stimulus Pulse Indicator and the audible chirp. The Stimulus Amplitude Control dial provides variable current control (0.05 to 5 milliamps). If your unit fails to meet the following specifications, please contact Life-Tech or your local distributor for service. 2. Specifications Regulatory Standards: Ingress Protection: UL CSA22.2No CE Marked to MDD EC93/42 EN EN EN EN EN EN55011B, Group 1 IP-21 (Tracer III) IP-07 (Solostim foot control) Size (WxLxH): Pocket size, 3.25" (8.3cm) wide x 6.0" (15.3cm) long x 2.25" (5.7cm) high (including knob) Weight: 9.6 oz (275gm) w/ 9V battery Battery: One 9V Alkaline Battery Output Current: mA with + 1% accuracy from ma (into load of 12k Ohms or less) Pulse Width: 50, 100, 300, 500, 1000 microseconds ± 1% Pulse Risetime: Less than 5 microseconds Pulse Frequency: Programmable 1Hz/2Hz ± 1% Storage Environment: -40 o to 70 o Celsius (-40 o to 158 o F) Operating Environment: 10 o to 40 o Celsius (50 o to 104 o F) 3. Meaning of Symbols: These symbols may appear on the unit. Danger- Do Not Use in the presence of flammable anesthetics Type BF Equipment Attention! Please Read Operator's Manual 2 Not User Serviceable Refers to operations with foot control
7 SECTION 3 TRACER III DISPLAY, CONTROLS AND INPUTS Figure 3.1: Display, Controls and Inputs 3
8 1 Display: The LCD (Figure 3.2) displays all of the settings programmed into the unit, as well as the status of various functions. Figure 3.2: Tracer III LCD a b Stimulus Range Setting: This field of the LCD displays the maximum stimulus current setting you can achieve by turning the Stimulus Control knob or pressing the foot control. The default range is 0.05mA to 5.0mA and can only be changed to 1.5mA when the unit is used with the optional foot control. Battery Life Indicator: Battery Life Remaining % % % % % 4
9 The LED segments of the Battery Life Indicator are solidly illuminated to the level of current battery life during use until the battery life drops below 20% (less than 8 hours of operation remaining) at which time, the lowest segment (as well as the battery outline itself) will flash at a rate of 1Hz. When the battery life is reduced to a voltage that is indicative of less than four hours of operation remaining, the lowest segment (as well as the battery outline itself) will flash at a 2Hz rate. Caution: Operation will cease when battery voltage is insufficient for the unit to function within specifications. c d e f g Stimulus Repetition Rate: This field of the LCD displays the rate (in Hz) at which the stimulus pulses are delivered. The default setting of 2Hz can be changed to 1Hz by pressing the Stimulus Repetition Rate button (6). Pulse Width: This field of the LCD displays the width (duration) of the stimulus pulses. The pulse width selections are: 0.05, 0.1, 0.3, 0.5 or 1.0 millisecond (msec). The default (0.1 msec) or present setting can be changed by pressing the Pulse Width button (Figure 3.1, button 5). Stimulus Setting/Output Display: This field of the LCD displays the stimulus setting/output level of the unit in milliamps (ma). The stimulus output is set either using the Stimulus Control knob (Figure 3.1, number 2) or the optional foot control. Whenever the unit detects an open/disconnected lead condition or is unable to deliver the displayed current setting, it will flash the output level display, and emit an audible 6 chirp alarm. The output level display is static when the unit is paused and when stimulus pulses are being delivered. The audible chirp heard with each stimulus pulse (1 or 2Hz Rate), will change in duration according to the delivered Stimulus Output: Long Chirp - For Current Levels between 1.0mA and 5.0mA. Medium Chirp - For Current Levels between 0.50mA and 0.99mA. Short Chirp - For Current Levels between 0.25mA and 0.49mA. Micro Chirp - For Current Levels below 0.25mA. Pulse Indicator: Flashes whenever a stimulus pulse is delivered. An audible chirp accompanies each flash of the pulse indicator. The stimulus pulse indicator will not flash in either an open lead condition or in pause. Pause Indicator: Vertical bars illuminate when in the Pause mode. The audible chirp ceases when the unit is paused. 5
10 2 Stimulus Control Knob: Rotation of this knob changes the stimulus setting (if paused or open lead) or the stimulus output current (if connected and not paused). NOTE: In this manual, this symbol (at right) designates operations that only apply when using the Stimulus Control Knob in the absence of the foot control. 3 Chirp Volume-Increase button: Press this button to increase the volume of the chirp that accompanies each stimulus output pulse in increments. Press and hold the button for 4 seconds to reach maximum volume. 4 Chirp Volume-Decrease button: Press this button to decrease the volume of the chirp that accompanies each stimulus output pulse in increments. Press and hold the button for 4 seconds to reach minimum volume. NOTE: There are five levels of chirp volume, the default and four (4) levels up from the default. 5 Pulse Width button: Each time you press the button the pulse width increases to the next higher setting until it cycles back to the lowest setting. 6 Stimulus Repetition Rate button: Press this button to toggle between 2Hz and 1Hz. 7 Pause button: Press this button to pause the stimulus output pulse. 8 On/Off button: Press this button to turn the unit ON and OFF. NOTE: The unit will auto-power off after it has been in an open lead condition or paused for 20 minutes. 9 Foot Control Input Connector: 5-pin connector to attach the optional foot control input cable. NOTE: In this manual, this symbol designates operations that only apply when using the foot control. 10 Patient Lead Output Connector: 4-pin connector to attach the patient lead wire set (RBW-5L). NOTE: The regional lead wire set is connected to the patient lead output connector. 6
11 SECTION 4 ASSEMBLY 1. To apply the optional Protective Boot, roll the sides of the boot open and slide the unit in, as shown below. Fold the stand out for table-top placement of the unit. Figure 4.1: Protective Boot (PB) 2. To use the optional Mounting Bracket and Protective Boot: a. Remove the stand from the back of the Protective Boot. b. Assemble the two components as shown below. c. Attach to an IV pole. Figure 4.2: Protective Boot with Mounting Bracket (MB-5) 7
12 SECTION 5 OPERATING PROCEDURES Figure 5.1-Connections 8
13 1. If the Tracer III is on, press to turn it off. 2. Set the Stimulus Control knob to the minimal current setting (full counter-clockwise). 3. Attach patient/accessory cables. Plug the (reusable) RBW-5L Lead Wire Set into the 4-pin output connector on the side of the unit. CAUTION! Take care that you do NOT attempt to force the 4-pin RBW-5L into the 5-pin foot control input, marked. This will cause the unit to malfunction and could damage the connector on the lead set. And, if using the Plug the foot control cable into the jack marked. WARNING: Take care to insure that the foot control is NOT disconnected from the unit when it is ON and connected to the patient. Should this occur, the stimulus output will revert to the Stimulus Control Knob setting. 4. Position the nerve stimulator such that the display is clearly seen during the procedure. And, if using the Position the foot control on the floor with the cable routed away from the sterile field. Set the foot control starting position as heel down, or depressed, for a minimum current setting when the unit is turned on. 5. Connect the Surface Electrode (Figure 5.1): a. Attach the red lead wire snap to the surface electrode. b. Peel the protective paper off the surface electrode and confirm that the conductive gel on the eletrode has not dried. c. Apply electrode to clean, degreased and shaved skin that is not in the distribution area of the nerve to be blocked. 6. Press the On/Off (I/O) button to turn the unit on. An open lead condition (i.e., the needle, ground electrode, or both, are not yet connected to the patient) will be indicated by the flashing Stimulus Setting/Output display and the audible 6-chirp alarm. 9
14 And, if using the Verify the range shown on the LCD is the desired range. The foot control operates in two range settings, for better stimulus resolution (control). The ranges are: 0.05mA to 1.5mA (1.5mA on the LCD) - Or mA to 5.0mA (5.0mA on the LCD) To switch between the ranges: a. DEPRESS the foot control back until you feel the first stop, and hold in that position until the Stimulus Setting/Output display reads 0.05mA. b. Firmly DEPRESS the foot control further down to the final stop. This action causes a toggle switch within the foot control to change between the two operating ranges. The new setting will now be seen in the Stimulus Range display of the LCD. 7. Set the initial desired stimulus output. If using the Rotate the Stimulus Control knob clockwise to increase current or counter-clockwise to decrease current. Or, if using the Observe the LCD while you: a. PRESS the foot control forward with the toes to increase stimulus output. b. DEPRESS back with the heel to decrease the output. 10
15 8. Connect the regional block needle (Fig. 5.1) and proceed in accordance with preferred regional block anesthesia techniques. ProBloc and ProLong regional block needles connect directly into the black touch-proof connector on the regional block lead wire set (RBW-5L). 9. Perform procedure following instructions for the regional block needle. 10. When the procedure has been completed, ensure that the unit has been turned off and remove the surface electrode. Disconnect the reusable regional block lead wire set from the stimulating wire of the needle. NOTE: For ease of removal, use a slight twist to disconnect the stimulating lead on the needle from the lead wire set. 11. Dispose of the needle in an approved sharps container following the Center for Disease Control & Prevention and OSHA guidelines, or local equivalent. 12. Clean and disinfect the unit as required by your facility's infection control protocols, using the procedure outlined on page 13 of this manual. 11
16 SECTION 6 MAINTENANCE 1. General Other than replacing the battery periodically and keeping the unit free of debris and contaminants, Tracer III requires no user maintenance, and is not user serviceable. 2. Battery Replacement Replace the 9V alkaline battery whenever the LCD battery life indicator begins to flash, or every year, whichever comes sooner. NOTE: To maintain the Warranty for your Tracer III, replace batteries with alkaline type only. To replace the battery: a. Remove the battery compartment cover from the back of the unit. b. Remove the old battery by pulling up on it from the bottom end. c, d. Using the graphic in the battery compartment as a guide for orienting the (+) and (-) contacts, insert the new battery, bottom (flat end) first. Then, press down on the top of the battery until the contacts are secured in the clips. e. Replace the compartment cover. Figure 6.1: Battery Replacement 12
17 3. Cleaning & Disinfection To clean the Tracer III and/or foot control, and/or regional block lead wire set: a. Mix approximately a 1% solution of mild dishwashing detergent and water (1cc of detergent mixed with 100cc of water). b. Turn the unit off. c. Dampen a clean, soft cloth with the detergent solution and wipe to remove visible contaminants from the outside of the unit. NEVER pour or spray cleaning solution directly onto the unit or submerge it in a solution. d. Dampen a clean, soft cloth with sterile or distilled water and wipe to remove all residual detergent solution. e. Dry thoroughly with a clean, dry cloth. To disinfect the Tracer III and/or foot control: a. Turn the Tracer III unit off. b. Dampen a clean, soft cloth with either 90% isopropyl alcohol, or any commercially available solution intended for surface disinfection of medical electrical equipment, and wipe the exterior surface thoroughly. If solution is in spray form, spray it onto the cloth. NEVER pour or spray disinfecting solution directly onto the unit, or submerge it in the solution. c. Allow the solution to air dry for at least one minute, then dry thoroughly with a clean, dry cloth. 4. Required Service: The unit should be serviced by qualified service personnel when: Liquid has ingressed into the instrument. It does not appear to operate normally. It exhibits a marked change in performance. The enclosure is damaged. 13
18 SECTION 7 LIMITED WARRANTY Refer to LIMITED WARRANTY card for complete information. 14
19
20
OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-707A & AEU-707AV2 Implant / Surgery Systems
OPERATION AND MAINTENANCE INSTRUCTION MANUAL AEU-707A & AEU-707AV2 Implant / Surgery Systems TABLE OF CONTENTS: Introduction.........................1 Package Contents....................1 Setting Up the
More informationOPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-17B & AEU-17BV2 Implant / Surgery Systems
OPERATION AND MAINTENANCE INSTRUCTION MANUAL AEU-17B & AEU-17BV2 Implant / Surgery Systems TABLE OF CONTENTS: Specifications........................i Introduction.........................1 Package Contents....................1
More informationSentinel Enteral Feeding Pump. Model: S-1000-SI. Operating Manual
Sentinel Enteral Feeding Pump Model: S-1000-SI Operating Manual CONTENTS 1. Introduction.. 2 2. Control Panel 5 3. Operating Instructions.. 6 4. Indicators and Alarms.. 9 5. Maintenance.. 10 6. Troubleshooting
More informationSurePower Battery Pack Guide
? SurePower Battery Pack Guide 9650-0536-01 Rev. B The issue date for the SurePower Battery Pack Guide (9650-0536-01 Rev. B) is September, 2010. If more than three years have elapsed since the issue date,
More informationMagstim MRI Coil Operating Manual
Magstim MRI Coil 3812-00 Operating Manual TABLE OF CONTENTS Page Numbers Section 1: Warranty 1 Section 2: Section 3: Indications for Use Contraindications Magstim MRI Coil Introduction D70mm MRI Coil System
More informationTIF8800X. Combustible Gas Detector. an spx brand. Owner s Manual. 99 Washington Street Melrose, MA Phone Toll Free
an spx brand TIF8800X Combustible Gas Detector 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Owner s Manual Safety Precautions
More informationNimbus Flex Ambulatory Infusion Pump
Nimbus Flex Ambulatory Infusion Pump Patient Manual Continuous Mode Infusions (Software Version v5.1.1) Read this entire manual prior to operating the Nimbus Ambulatory Infusion Pump. Failure to follow
More informationRemRest. Service Manual. CAUTION: USA Federal law restricts this device to sale by or on the order of a physician. P/N Rev A
RemRest Tiers 1-3 900 Series Service Manual CAUTION: USA Federal law restricts this device to sale by or on the order of a physician. P/N 22054 Rev A Table of Contents IEC Symbols 3 SIZE 4.7" H X 8.6"
More informationDCell Suction. Model DM Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority
DCell Suction Model DM10-001 Clearing The Airway Is Our #1 Priority Operating Instructions & Maintenance Manual, INC. 11064 Randall Street Sun Valley, CA 91352 USA www.sscor.com Email: marketing@sscor.com
More informationSurePower TM II Battery Pack Guide
TM SurePower TM II Battery Pack Guide? 1:00+ 2:00+ 3:00+ TM 9650-000840-01 Rev. B The issue date for the SurePower II Battery Pack Guide (REF 9650-000840-01 Rev. B) is December, 2012. If more than three
More informationTIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer
TIC 300 PRO High Energy Tic Tracer Non Contact AC Voltage Detector Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso TIC 300 PRO High Energy Tic Tracer Non Contact AC Voltage Detector
More informationOPERATING MANUAL POWER DRIVE SYSTEM. Cat. No RevH
OPERATING MANUAL POWER DRIVE SYSTEM Cat. No. 400005 525-1300-00 RevH System components Symbol Definitions Qty Description Catalog Number 1 Power Drive System 300106 1 Controller 300108 1 Cutter Drive
More informationQuickdraw. Model 2400 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority
Quickdraw Model 2400 Series Clearing The Airway Is Our #1 Priority Operating Instructions & Maintenance Manual, INC. 11064 Randall Street Sun Valley, CA 91352 USA www.sscor.com Email: marketing@sscor.com
More informationMEDICAL IRRIGATION K PUMP OPERATING MANUAL: Manufactured for: K.M.I 3185 Palisades Dr Corona CA USA Model No.
OPERATING MANUAL: MEDICAL IRRIGATION K PUMP Manufactured for: K.M.I 3185 Palisades Dr Corona CA 92880-9432 USA 1-866-412-7867 Model No. 1000-0031 A-1299-5091 Edition 01 TABLE OF CONTENTS Title SAFETY PRECAUTIONS
More informationQuick Reference Guide
Quick Reference Guide 3 Spike Set Cassette Inflow Connector Cassette Outflow Connector Return Line Latch Handle Patient Line Air Trap Keypad Cassette Customer Service Toll Free: 1-866-944-9992 Office:
More informationModel 2310 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority
VX-2 Model 2310 Series Clearing The Airway Is Our #1 Priority Operating Instructions & Maintenance Manual, INC. 11064 Randall Street Sun Valley, CA 91352 USA www.sscor.com Email: marketing@sscor.com techsupport@sscor.com
More information6 Bay Battery Charger Operation Manual
6 Bay Battery Charger Operation Manual Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216 USA Customer Service: 904 737 7611 Toll Free 877 677 2832 EC REP RMS UK, Ltd. 28 Trinity Road
More informationBodyGuardTM 323. BodyGuard 323 Multi-Therapy Ambulatory Infusion Pump. Patient Guide
BodyGuardTM 323 BodyGuard 323 Multi-Therapy Ambulatory Infusion Pump Patient Guide How to Use This Booklet This booklet gives you information about how to use your BodyGuard 323 infusion pump. It supplements
More informationCGD8800X CGD8800X220 Combustible Gas Detector
CGD8800X CGD8800X220 Combustible Gas Detector Background and Purpose The CGD8800X Combustible Gas Detector offers significantly improved hydrocarbon detection while featuring visual concentration indicators
More informationHEINE NT4 MED V
HEINE NT4 MED 113594 2018-01-23 V-200.00.601 HEINE NT4 Please read and follow these instructions for use and keep them for future reference. Intended Use The HEINE charger NT4 is to be used exclusively
More informationDIGITAL RCD(ELCB) TESTER
INSTRUCTION MANUAL DIGITAL RCD(ELCB) TESTER KEW 5410 R KYORITSU ELECTRICAL INSTRUMENTS WORKS, LTD. Contents 1. Safety Warnings.... 1 2. Procedure of removing Cover. 3 2-1 Method of removing the Cover.
More informationTX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free
TX900 Microwave Leakage Detector 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Users Manual TX900 Microwave Leakage Detector
More informationUsers Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery
MS5900 Users Manual Table of Contents Introduction Motor and Phase Rotation Indicator is a handheld, battery-operated instrument designed to detect the rotary field of three-phase systems and determine
More informationOPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-707A & AEU-707AV2 Implant / Surgery Systems
OPERATION AND MAINTENANCE INSTRUCTION MANUAL AEU-707A & AEU-707AV2 Implant / Surgery Systems TABLE OF CONTENTS: Introduction.........................1 Package Contents....................1 Setting Up the
More informationInstruction manual. High voltage insulation resistance tester KEW3121B/3122B
Instruction manual High voltage insulation resistance tester KEW3121B/3122B Contents 1. Safety warnings... 1 2. Features... 5 3. Specification... 6 4. Instrument layout... 9 5. Getting started... 10 5-1
More informationEndodontic Handpiece (GT) USER MANUAL
Endodontic Handpiece (GT) USER MANUAL 1 USER MANUAL Read Instruction Before Use SECTION 1: General Introduction Cordless Endo Motor GT3 is a kind of endodontic micromotor to operate NI-Ti files, and it
More informationB-RAD Select USER MANUAL TABLE OF CONTENTS
TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE... 3 1.0 General Information... 5 1.1 System Components... 5 1.2 Specifications... 5 1.2.1 Torque Ranges...
More informationLLS-2054BE. Smart Battery Pack Operator Manual. ST Technologies 6018 Bowdendale Avenue Jacksonville, FL USA
LLS-2054BE Smart Battery Pack Operator Manual ST Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216 USA Customer Service: 904 208-2290 Toll Free 877-814-2237 EC REP RMS UK, Ltd. 28 Trinity Road
More informationBRAVER UPS. (Uninterruptible Power System) User s Manual
BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.
More informationDigital Apex Locator. ipex OPERATION MANUAL OM-E0285E
Digital Apex Locator ipex OPERATION MANUAL 0197 OM-E0285E The EU directive 93/42/EEC was applied in the design and production of this medical device. Thank you for purchasing the ipex. This is apex locator.
More informationOperator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:
Storage System Ultrasound Probe Cabinet Operator's Manual Manufactured by: CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA 319.248.6757 / 800.445.6741 WWW.CIVCO.COM Copyright 2018 All
More informationOPERATION and MAINTENANCE INSTRUCTION MANUAL. AEU-10C/SS Power-Tip Systems
OPERATION and MAINTENANCE INSTRUCTION MANUAL AEU-10C/SS Power-Tip Systems TABLE OF CONTENTS: Introduction.........................1 Package Contents....................1 Setting Up the Unit...................2
More informationIMPORTANT SAFETY INSTRUCTIONS VP200ESK SAFETY INSTRUCTIONS 1
IMPORTANT SAFETY INSTRUCTIONS VP200ESK SAFETY INSTRUCTIONS VP200ESK SAFETY INSTRUCTIONS 2 MAIN COMPONENTS ITEMS INCLUDED SPRAYER TANK 6.8 VOLT BATTERY -3400 mah 6.8 VOLT CHARGER NOZZLE WRENCH TANK CAP
More informationWater Level Meter + Temperature
Water Level Meter + Temperature Installation and Operation Manual Rev 05/23/2017 Part # 12050744 Table of Contents SECTION 1: SYSTEM DESCRIPTION... 3 SECTION 2: SYSTEM INSTALLATION... 6 SECTION 3: SYSTEM
More informationDENTAL LIGHT 300LED DENTAL LIGHT OPERATING INSTRUCTIONS IMPORTANT
DENTAL LIGHT 300LED DENTAL LIGHT TYPE OPERATING INSTRUCTIONS 320M UNIT MOUNT IMPORTANT Thank you for purchasing TAKARA BELMONT product. This manual provides operating instructions for the 300LED DENTAL
More informationUser Manual SONESTA S2 & S3
User Manual SONESTA S2 & S3 Sonesta manufactures and sells tables and chairs for urology, gynecology, urodynamic diagnostics and upper GI procedures Copyright 2018 SONESTA MEDICAL AB. All rights reserved.
More information60V RECHARGEABLE LITHIUM-ION BATTERY
60V RECHARGEABLE LITHIUM-ION BATTERY LB60A00/LB60A03/LB60A01/LB60A02 Owner s Manual TOLL-FREE HELPLINE: 1-855-345-3934 www.greenworkstools.com Read all safety rules and instructions carefully before operating
More informationDifferential Pressure Transmitter
Specifications/Instructions Differential Pressure Transmitter General Model PY9000D is a differential pressure transmitter that uses a ceramic cantilever sensor. Deflection of the ceramic cantilever caused
More informationDIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE
DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE W.CHRISTIE (INDUSTRIAL) LTD CHRISTIE HOUSE, MEADOWBANK ROAD, ROTHERHAM, SOUTH YORKSHIRE, S61 2NF, UK T: +44(0)1709 550088 F: +44(0)1709 550030 E:
More informationOPERATING INSTRUCTION
11/05 Form #273 OPERATING INSTRUCTION MODEL 4105 Disital Earth Resistance Tester 2150 joshua's Path, Suite 302, Hauppauge, NY 11788 Phone : 1-800-645-5398 or 1-639-231-7050 Fax : 1-639-434-3128 E-mail
More informationLM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to
LM-100 LM-120 Light Meters Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com LM-100 / LM-120 Light Meters English Users Manual LM100_Rev002 2008 Amprobe Test Tools.
More informationMini Multimeter with Non-Contact Voltage Detector (NCV)
Owner s Manual Mini Multimeter with Non-Contact Voltage Detector (NCV) Model No. 82314 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.
More informationCordless Rechargeable Saw Instructions for Use
Technical data Voltage: DC 10.8V Weight: 1.25Kg Stroke rate: 0-2100/min Stroke: 15mm Cutting capacity: max diameter in wood 80mm / in soft metal 7mm Charging time: Between 5.0-5.5 Hours Battery: 1.3Ah
More informationINSTRUCTIONS EVIS EXERA XENON LIGHT SOURCE OLYMPUS CLV-160
INSTRUCTIONS EVIS EXERA XENON LIGHT SOURCE OLYMPUS CLV-160 Contents Contents Labels and Symbols... 1 Important Information Please Read Before Use... 3 Intended use... 3 Instruction manual... 3 User qualifications...
More information8-Bay Rapid Charger. for AA/AAA NiMH & NiCd Rechargeable Batteries. Owner's Manual. Please read before using this equipment.
8-Bay Rapid Charger for AA/AAA NiMH & NiCd Rechargeable Batteries Owner's Manual Please read before using this equipment. Thank you for purchasing the Watson 8-Bay Rapid Charger. Browse through this manual
More informationRS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to
RS-3 PRO RS-1007 PRO CAT IV Analog Clamp meter Series Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com RS-3 PRO RS-1007 PRO CAT IV Analog Clampmeter Series English
More informationSelf-Leveling Rotary Laser Level with GreenBrite Technology Model No Instruction Manual
1621H-English 9/4/08 9:05 AM Page 1 Self-Leveling Rotary Laser Level with GreenBrite Technology Model No. 40-6543 Instruction Manual Congratulations on your choice of this Self-Leveling Rotary Laser Level
More informationLED OPERATORY LIGHT Instructions For Use
OVERVIEW Post Mount Light LP4000 / LP4050 LP5000 / LP5050 Ceiling Mount Light LC4000 / LC4050 LC5000 / LC5050 System Mount Light LS4000 / LS4050 LS5000 / LS5050 Track Mount Light LT4000 / LT4050 LT5000
More informationCondor Manual. Corporation
Condor Manual Corporation PREFACE IMPORTANT, PLEASE READ CAREFULLY Thank you for your purchase with Amico Accessories Inc. This unit is designed for long lasting performance, providing the end user complies
More informationKeeler Spectra Plus. Instructions. Next
Keeler Spectra Plus Instructions Next Introduction Thank you for purchasing the Keeler Spectra Plus Indirect Ophthalmoscope. We have taken the greatest care in the design, development and manufacture of
More informationAdtemp TM V 418 Digital Fever Thermometer USE, CARE & MAINTENANCE
Adtemp TM V 418 Digital Fever Thermometer USE, CARE & MAINTENANCE 1 Intended Use: A digital thermometer is a device used to measure the body temperature of a patient by means of a transducer coupled with
More informationMarin Control Digital
Operation Manual Marin Control Digital Digital Meter for the measurement of Temperature, salinity and specific gravity in saltwater aquariums. Short instructions: ON OFF : Is used to turn the power on
More informationMARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions
4.4 Storage Conditions The FD650/R and FD500/T or FD600/T should be kept in warm dry conditions away from direct sources of heat or sunlight, with the battery removed and in such a manner as to preserve
More informationLIGHTBOLT MAX EXTENDABLE WORK LIGHT INSTRUCTION MANUAL. Model No. 4063
LIGHTBOLT MAX EXTENDABLE WORK LIGHT Model No. 4063 INSTRUCTION MANUAL MobilePower, LLC. Miami, FL www.mobilepower-us.com Customer Support: (800) 708-8550 customerservice@mobilepower-us.com BEFORE YOU USE
More information5.2 PRE-OPERATION PROCEDURE WARRANTY
4/02 Form #314 OPERATING INSTRUCTIONS MODELS DM-210A, 220A, 230A DIGITAL MULTIMETER PLEASE READ THESE OPERATING INSTRUCTIONS CAREFULLY Misuse and or abuse of these instruments cannot be prevented by any
More informationInstruction Manual for Safety and Comfort
GMH500160110 *GMH500160110* Instruction Manual for Safety and Comfort All of the Safety Instructions contained in this Manual must be read carefully and must be fully understood before you attempt to use
More informationOPERATING INSTRUCTION
11/05 Form #271 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 OPERATING INSTRUCTION Visit us at www.testequipmentdepot.com MODEL 3132 ANALOG INSULATION-CONTINUITY TESTER
More informationLED-HL2-CMP LED Headlight System Operation Manual
LED-HL2-CMP LED Headlight System Operation Manual Manufactured for: Cardio Medical Products, Inc. 385 Franklin Avenue, Suite L Rockaway, NJ 07866 USA Customer Service: 800-227-3633 info@cardiomedicalproducts.com
More informationSeekTech Inductive Clamp
Inductive Clamp Manual SeekTech Inductive Clamp! Read this Operator s Manual carefully before using this tool. Failure to understand and follow the contents of this manual may result in electrical shock,
More informationSmartVent. Instructions for Use Version 4 (Dec 2009)
SmartVent Instructions for Use Version 4 (Dec 2009) SmartVent is a radioaerosol delivery system that has been developed to give unrivalled performance for lung ventilation scintigraphy. Consistent, excellent
More informationPRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to
PRM-4 Phase Sequence and Motor Rotation Tester Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com PRM-4 Phase Sequence and Motor Rotation Tester English Users Manual
More informationUSE, CARE & STERILIZATION INSTRUCTIONS. Consumable Accessories Burs Saw Blades K-Wires Steinmann Pins Twist Drills Rasps Ortho Pins/Drills Guide Wires
USE, CARE & STERILIZATION INSTRUCTIONS Consumable Accessories Burs Saw Blades K-Wires Steinmann Pins Twist Drills Rasps Ortho Pins/Drills Guide Wires Rx Only EXPLANATION OF SYMBOLS 2 g h i N B D L M d
More informationHydraulic PTO Flow Device
Safety, Operation, and Maintenance Manual WARNING Improper use of this tool can result in serious bodily injury This manual contains important information about product function and safety. Please read
More informations h a p e f i t t i n g t e c h n o l o g y
Operation Manual Supplier: This manual must be given to the user of this product. Operator (Individual or Caregiver): Before using this product, read instructions and save for future reference. s h a p
More informationThermistor Thermometer MODEL NO
Digi -Sense Thermistor Thermometer MODEL NO. 60010-70 Digi -Sense CERTIFICATE OF CONFORMANCE This thermometer was calibrated using equipment traceable to the National Institute of Standards and Technology
More informationportable ac/dc suction pump USER S MANUAL ITEM # 18605
portable ac/dc suction pump USER S MANUAL ITEM # 18605 index 1 1. Safety Information...2-4 2. AC Power Source...3 3. Electrical...3-4 4. Introduction...4 5. Illustration of Important Parts...5 6. Set-Up...6
More informationLASER ENHANCED SEMI-AUTOMATIC GRIP OWNER S MANUAL RED LASER GREEN LASER
LASER ENHANCED RED LASER GREEN LASER SEMI-AUTOMATIC GRIP OWNER S MANUAL LASER ENHANCED GRIP Installation Instructions Caution... 3 Safety Labels... 4 Rubber Grip Installation...5-6 G10 and Wood Grip Installation...7-8
More informationIntroduction. The words WARNING, CAUTION and NOTE carry special meanings and should be carefully reviewed.
Operations/ Maintenance Manual Important Information File in your maintenance records Medical Visum Exam Light Model LL305 For parts or technical assistance call 800 327 0770 (option 2) Table of Contents
More informationVHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm with Slide-In Mounting Plate
3875 Cypress Drive Petaluma, CA 94954 800.228.2555 +1.707.773.1100 Fax 707.773.1180 www.gcx.com VHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm with Slide-In Mounting Plate (Refer to qualified
More information3875 Cypress Drive Petaluma, CA Fax
3875 Cypress Drive Petaluma, CA 94954 800.228.2555 +1.707.773.1100 Fax 707.773.1180 www.gcx.com VHM-P (Non-Locking) Variable Height Arm with Fixed Angle Front End for Flat Panel / Keyboard Bracket (L Brackets
More informationHydraulic Immediate Need Power Pack
Safety, Operation, and Maintenance Manual WARNING Improper use of this tool can result in serious bodily injury This manual contains important information about product function and safety. Please read
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS BATTERY CHARGER IR-200BC TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 2 2. GENERAL DESCRIPTION... 3 3. HANDLING PRECAUTIONS... 3 4. NOMENCLATURE AND FUNCTIONS... 4 5. CHARGING... 5
More informationCentrifuge Operator / Service Manual
3000 Centrifuge Centrifuge Operator / Service Manual cat.# 26230 & 26231 The Q-sep 3000 centrifuge complies with all requirements of UL standard 3101 20, Can/CSA C22.2 No. 1010.1, and Can/CSA C22.2 No.
More informationOperator s Manual. Pre-Clinical Blood Sampling Tool
Operator s Manual Pre-Clinical Blood Sampling Tool + Read the entire Operator s Manual before using GentleSharp Model 101. Disregarding the cautions and instructions presented in this manual constitutes
More information1200W INVERTER GENERATOR
1200W INVERTER GENERATOR MODEL NO: IG1200 PART NO: 8877070 OPERATION & MAINTENANCE INSTRUCTIONS LS0117 INTRODUCTION Thank you for purchasing this CLARKE 1200W Inverter Generator. Before attempting to use
More informationIGLOO IGLOO EASY INSTRUCTION MANUAL
ENGLISH EASY C695 C698 INSTRUCTION MANUAL Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky range, has
More informationWPS600. Hydraulic Pressure Transducer. User s Guide. 600 bar 60 MPa 8700 psi
WPS600 Hydraulic Pressure Transducer User s Guide This accessory complies with the following standards: Electromagnetic Compatibility (EMC) Directive 2004/108/EC FCC Part 15 Pressure Equipment Directive
More informationBM kv Digital Insulation Tester USER MANUAL
M BM5200 5 kv Digital Insulation Tester USER MANUAL CONTENTS Safety warnings...3 Symbols used on instrument...4 Cleaning...4 General description...5 Insulation resistance test modes...5 Automatic discharge...5
More information5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810
5 IN 1 JUMP START MODEL NO: JS5IN1 PART NO: 6240005 OPERATION & MAINTENANCE INSTRUCTIONS LS0810 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product, please
More informationLumitester PD-20 Control Kit
日本語による取扱説明は 17 ページからとなります Lumitester PD-20 Control Kit Operation manual Thank you for purchasing the Lumitester PD-20 Control Kit. To use this kit safely and correctly, read this operation manual carefully
More informationDC POWER SUPPLY ALIMENTATION C.C.
DC POWER SUPPLY ALIMENTATION C.C. ISO-TECH IPS 303A 201-3424 ISO-TECH IPS 601A 201-3446 SAFETY TERMS AND SYMBOLS These terms may appear in this manual or on the product: WARNING. Warning statements identify
More informationD Instructions/Parts. Siphon Feed Detail Spray Gun D
Instructions/Parts D-5-55 Siphon Feed Detail Spray Gun FOR PRODUCT INFORMATION CALL: 1-800-742-7731 309991D Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions.
More informationLaerdal Compact Suction Unit 4
Laerdal Compact Suction Unit 4 Cat. No. 880051 Cat. No. 88 Contents 1 LCSU 4 Overview Information 4 LCSU 4-800 ml (Cat. No. 880051) 4 LCSU 4-300 ml (Cat. No. 880061) 4 2 Description and Intended Use Intended
More informationOperating Instructions. International English. CCS Dust Extractor
Operating Instructions International English CCS Dust Extractor Electric Cast Saw Dust Removal System Warnings & Safety Rules WARNING!: THIS EQUIPMENT MUST BE EARTHED! Danger!: Possible explosion hazard
More informationUSER MANUAL READ THIS MANUAL BEFORE OPERATING THIS DEVICE. SAVE THIS MANUAL FOR FUTURE REFERENCE. DEALER: THIS MANUAL MUST BE GIVEN TO THE END USER.
Oxlife INDEPENDENCE INTRODUCTION PORTABLE OXYGEN CONCENTRATOR USER: USER MANUAL READ THIS MANUAL BEFORE OPERATING THIS DEVICE. SAVE THIS MANUAL FOR FUTURE REFERENCE. DEALER: THIS MANUAL MUST BE GIVEN TO
More informationABSOLUTE EQUIPMENT PTY LTD
Manual Hydraulic Toe Jack Model DTJ Series ABSOLUTE EQUIPMENT PTY LTD 2/186 Granite Street, GEEBUNG QLD 4034 Australia sales@absoluteequipment.com.au Phone: +61 7 3865 4006 Fax: +61 7 3102 6288 This is
More informationPodiatry Procedures Chair. For Models: Barrier-Free. User s Guide
Podiatry Procedures Chair For Models: 646 647 Barrier-Free User s Guide Product Information (The information below is required when calling for service.) Dealer : Date of Purchase: Model / Serial Number:
More informationAirless Spray Gun INSTRUCTIONS DP psi (345 bar) Maximum Working Pressure
INSTRUCTIONS DP-6376 Airless Spray Gun 5000 psi (345 bar) Maximum Working Pressure INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Table of Contents Warnings......................................
More informationBEGINNER ELECTROSEX KIT
BEGINNER ELECTROSEX KIT Instruction Manual CAUTION! IMPORTANT INFORMATION Electrosex kit can cause serious harm. Certain people should not use electrosex devices. All users must read this section before
More informationSURGICAL POWER & ACCESSORIES. Rx Only PM-X00-710/PM-X IR-12.13
SURGICAL POWER & ACCESSORIES Rx Only PM-X00-710/PM-X00-715-IR-12.13 Table of Contents Introduction Page 4 Intended Use Page 4 Warnings Page 5 Cautions Page 5 Notes Page 5 Explanation of Symbols Page 6
More informationSolar mosquito killer
Solar mosquito killer Model 96415 Assembly And Operation Instructions Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so can result in serious
More informationUltraviolet Fluorescent Lighting Fixtures WF-EM2B, WF-EM4B WF-EM2M, WF-EM4M WF-EM22D, WF-EM4D WF-EM2R, WF-EM4R WF-EMMIM
Operation Manual Ultraviolet Fluorescent Lighting Fixtures WF-EM2B, WF-EM4B WF-EM2M, WF-EM4M WF-EM22D, WF-EM4D WF-EM2R, WF-EM4R WF-EMMIM Table of Contents Specifications 3 General 3 DMX Units 3 Remote
More informationMICRO-START SAFETY GUIDE
ANTIGRAVITY BATTERIES MICRO-START ALL MODELS 2018 CONTENTS: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 IMPORTANT INTRODUCTION PERSONAL PRECAUTION MINORS CHOKING HAZARD HANDLING MODIFICATIONS ACCESSORIES
More informationSelf-Testing Industrial Series
Series: AS-I (Maint.-Free) Self-Testing Industrial Series Emergency Lighting Equipment Instructions for INSTALLATION OPERATION SERVICE SPECIFICATIONS 1300650 1300654 1300666 1300754 1300823 1300886 Hubbell
More informationMGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.
Instructions/Parts MGFHVLP Mini Gravity Feed System FOR PRODUCT INFORMATION CALL: 1-800-742-7731 309989E For gravity feed spraying of automotive colors and clears. Ideal for touch-up and detail work. Important
More informationPrice Computing Scale D Series Operation Manual
This Document is Hosted by: www.oldwillknottscales.com Price Computing Scale D Series Operation Manual Cardinal Scale Manufacturing Co. 8529-M400-O1 Rev. A PO BOX 151 WEBB CITY, MO 64870 04/13 PH (417)
More informationABSOLUTE EQUIPMENT PTY LTD
Manual Hydraulic Toe Jack Model DTJ Series ABSOLUTE EQUIPMENT PTY LTD 2/186 Granite Street, GEEBUNG QLD 4034 Australia sales@absoluteequipment.com.au Phone: +61 7 3865 4006 Fax: +61 7 3102 6288 This is
More informationMemory Foam Massaging Bath Pillow with Wireless Remote Control
Memory Foam Massaging Bath Pillow with Wireless Remote Control Instruction For Use and Warranty Information Model AB225 Memory Foam Massaging Bath Pillow with Wireless Remote Control Memory Foam Pillow
More informationCEILING SPEAKER SYSTEM
INSTRUCTION MANUAL CEILING SPEAKER SYSTEM F-2352SC TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 2 2. GENERAL DESCRIPTION... 3 3. FEATURES... 3 4. NOMENCLATURE AND DIMENSIONS... 3 5. INSTALLATION... 4 6.
More informationUV-AIRE AIR PURIFYING SYSTEM
UV-AIRE AIR PURIFYING SYSTEM Model: UV-16/24 The UV-Aire unit is designed to emit powerful UVC Band light rays, which sterilize and reduce airborne microorganisms as they pass through a heating or air
More information