IMO-517 (7027) ISSUE 3/97 ERA12, 25, 50, 83, 125, 167, 208 AND 250 ELECTRIC ACTUATORS INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS

Size: px
Start display at page:

Download "IMO-517 (7027) ISSUE 3/97 ERA12, 25, 50, 83, 125, 167, 208 AND 250 ELECTRIC ACTUATORS INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS"

Transcription

1 ERA12, 25, 50, 83, 125, 167, IMO-517 (7027) ISSUE 3/ AND 250 ELECTRIC ACTUATORS INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS

2 2 Table of Contents 1 GENERAL Introduction Description WARNING CAUTION General Technical Information Operation INSTALLATION MANUAL OVERRIDE INSTRUCTIONS CAM ADJUSTMENT INSTRUCTIONS General Valve Open Position: (Switch #2) (Upper Switch) Valve Closed Position: (Switch #1) (Lower Switch) OPTIONAL ACCESSORIES IMO s for Optional Accessories OPERATING INSTRUCTIONS MAINTENANCE General Replacement of a Motor Control Limit Switch TROUBLE SHOOTING ASSEMBLY DRAWING/SPARE PARTS READ THESE INSTRUCTIONS FIRST! These instructions provide information about safe handling and operation of the actuator. If you require additional assistance, please contact your authorized Neles-Jamesbury distributor or representative. For address and phone number, call Neles-Jamesbury at (508) SAVE THESE INSTRUCTIONS! Subject to change without notice.

3 1 GENERAL 1.1 Introduction This instruction manual contains important information regarding the installation, operation and trouble shooting of Neles-Jamesbury s ERA Electric Actuator. Please read these instructions carefully and save them for future reference. 1.2 Description Neles-Jamesbury s ERA Series Electric Actuators are designed to provide reliable and efficient operation of 1/4 turn ball valves. The supported torque range for actuation is between 12 and 250 lb.-ft. The ERA Series is available in AC models with a 25% duty cycle and DC models with a 100% duty cycle. In addition, a variety of options and accessories are available. 2 INSTALLATION Mount these actuators by following actuator mounting instructions (AMI) contained in the linkage kit. To obtain copies of these, contact your nearest Neles-Jamesbury stocking distributor or representative or write: Neles-Jamesbury, Inc., Box 15004, 640 Lincoln St., Worcester, Massachusetts, The AC terminal strip is shown in Figure 1. Power is connected to (1) common, (2) close and (3) open, using a two-way switch, (4) and (5) are wired to the normally open leg of the motor control limit switches as shown in Figure WARNING BEFORE REMOVING THE COVER, SHUT OFF ELECTRICAL POWER AND DISCONNECT ELECTRICAL CONNECTIONS. TO PREVENT IGNITION OF HAZARDOUS ATMOSPHERES, DISCONNECT SUPPLY CIRCUIT BEFORE OPENING UNIT. KEEP ASSEMBLY TIGHTLY CLOSED WHEN IN OPERATION. TO MAINTAIN THE HAZARDOUS LOCATION RATING OF THE ERD ACTUATOR, IT IS ESSENTIAL THAT THE MATING SURFACES OF FLANGES BE PROTECTED FROM NICKS AND SCRATCHES WHILE DISASSEMBLED. UPON REASSEMBLY, THERE MUST BE NO DIRT OR PARTICLES ON THE MATING SURFACES OR FLANGES. 1.4 CAUTION WHENEVER AN ACTUATOR IS REMOVED FROM THE VALVE AND THEN REMOUNTED, THE LIMIT SWITCH SETTINGS MUST BE CHECKED TO MAKE SURE THE VALVE IS MAKING THE PROPER TRAVEL. REFERENCE THIS IMO FOR CAM ADJUSTMENT INSTRUCTIONS. WHEN SERVICING A VALVE/ACTUATOR ASSEMBLY, THE BEST PRACTICE IS TO REMOVE THE ENTIRE ASSEMBLY FROM SERVICE. Figure 1 The DC terminal strip is shown in Figure 2. DC voltage actuators require a reversing of the power polarity. To drive the actuator CW (CLOSED), apply power so that Terminal 3 is positive and Terminal 1 is negative. To drive the actuator CCW (OPEN), apply power so that Terminal 1 is positive and Terminal 2 is negative. VAC 1.5 General Technical Information ERA Series AC voltage actuators use a split phase motor. All of the ERA series actuators have a manual override capability. It is important to verify that the actuator output torque is appropriate for the torque requirements of the valve and that the actuator duty cycle is appropriate for the intended application. 1.6 Operation A 25% duty cycle means that for every operating cycle that the actuator is ON (to open or close the valve), the actuator must be OFF for a time equal to three operating cycles. For example; if the operating cycle time is 5 seconds, for every operating cycle that the actuator is ON, it must be OFF for 15 seconds. Exceeding the actuators rated duty cycle may cause the thermal overload switch to temporarily shut off power to the motor. Continual overload may burn out the motor. VDC Operating temperature range is -40º F to 150º F, however, below +40º F the heater option is required. Figure 2

4 4 3 MANUAL OVERRIDE INSTRUCTIONS All of the ERA Series Electric Actuators have a manual override feature. To activate the override, depress the actuator override shaft, while depressed, rotate CW or CCW until the desired valve position has been reached. To re-engage the drive motor, release the override shaft. (If the override shaft fails to re-engage, rotate slightly in either direction.) Reference tag on cover for open and closed rotation, the output shaft may rotate in opposite direction of the override shaft. 4 CAM ADJUSTMENT INSTRUCTIONS 4.1 General There are NO TOOLS REQUIRED to adjust the cams. The cam is a friction fit to the shaft. Cams are adjusted by rotating the cam on the shaft by hand. To adjust for proper valve open and close positions, the cams for the motor control limit switches #1 and #2 must be moved as follows: A butterfly valve is fully open when the disc is perpendicular to the valve body flange. 4.3 Valve Closed Position: (Switch #1) (Lower Switch) If the valve needs to close more, (refer to the appropriate valve IMO for proper closed position) rotate the cam counterclockwise as viewed from the top of the motor. (See Figure 4) If less rotation is required, rotate the cam in the clockwise. Close Switch Package CW Open Switch Package CCW Figure 4 5 OPTIONAL ACCESSORIES 5.1 IMO s for Optional Accessories Please reference the following IMO s: IMO-521 For Potentiometer option. IMO-519 For Heater and Thermostat option. IMO-520 For Limit Switch option. IMO-522 For 4-20mA Feedback Option. 4.2 Valve Open Position: (Switch #2) (Upper Switch) Figure 3 If the valve needs to open more, rotate the cam clockwise as viewed from the top of the motor. (See Figure 3) If less valve rotation is required, then rotate the cam counterclockwise. For added ease in setting the cam there are three slots on the outside of each cam, these can be used to fine tune the final position of the cam lobe into the switch lever arm. The slots will accept the blade of a standard instrument type screw driver. The screw driver can be used as a lever arm to aid in moving the cam on the shaft. A ball valve is fully open when the hole in the ball is in the center of the valve body waterway. Any combination of options is possible. 6 OPERATING INSTRUCTIONS Normal operating voltages for electric actuators: 115 VAC, 230 VAC or as specified on the actuator. Refer to Product Bulletin A120-3 for torque output, duty cycle and operating speed. See wiring diagram for proper wiring. Operating temperature range is -40 F to +150 F, however, below +40 F the heater option is required.

5 5 MAINTENANCE General CAUTION Use the correct parts. Failure to do so could result in improper operation or personal injury. Contact your Neles- Jamesbury distributor for authentic Neles-Jamesbury replacement parts. 1. These actuators require no lubrication, and under normal operating conditions only periodic observation is needed to see that they are functioning properly. Maintenance or repair requirements other than those described herein, should be referred to Neles- Jamesbury for service. NOTE: ACactuators areequipped with thermal overload protection, if the actuator does not run, allow to cool before operating. 2. To remove the EU cover; remove the cover hold down screws. Extreme care must be taken to avoid any damage to mating faces of the cover flanges of EU actuators since scratches or nicks would violate hazardous location ratings. 3. To remove the capacitor, unplug the connector from the basic board and remove the capacitor from the wire tie. Remove two brake mounting screws. Disconnect cap leads from piggyback terminal (brake solenoid). 4. When reinstalling the cover, care must be taken not to allow the cover to cock in relation to the base. Care must be taken during reassembly that no particles or dirt are on the mating surfaces of flanges. Replace the cover and cover hold down screws. Tighten one screw partially, then another on the opposite side of the flange, repeating this procedure until all screws are partially tightened. Repeat this procedure to fully tighten screws. Replacement of a Motor Control Limit Switches To remove a limit switch package that is not working, pry the housing off of the mounting bracket or limit switch housing using a small instrument type screw driver. Slide the switch package up and off of the cam/gear shaft and discard. In most cases the switch package will be damaged during removal of the limit switch from the housing. A new housing is supplied with every limit switch. Each limit switch package is made up of: a limit switch housing, a cam, a prewired 5 AMP limit switch with a female connector. To install the switch package onto the top of an existing motor control limit switch, follow the steps as outlined below (See Figure 5): The standard convention for installing limit switches in Neles-Jamesbury products is the lower switch will control or indicate the close position, and the upper switch will control or indicate the open position. (1) Slide a fully assembled switch package over the cam/gear shaft and snap the locking legs into the holes on top of the switch housing or switch mounting bracket. The lower switch (the switch installed first) is used to control the CLOSE position of the actuator. (2) Repeat the procedure for the next switch. This switch would be used for control of the actuator OPEN position. (3) Attach the lead wire with the connector into the mating connector on the basic board. The connectors on the basic board are labeled OPEN and CLOSE. (4) Cam adjustments are made the same as in the Cam Adjustment section of this IMO. Switch Housing Cam/Gear Shaft Cam Locking Legs Switch Mounting Bracket Figure 5

6 6 8 TROUBLE SHOOTING Problem Try This 1. Motor will not run. 1. Check incoming voltage as it enters the terminal block #1 and #2 or #3 terminals. 2. Check that all plug-in connectors are tight. 3. Review the cam adjustment section to insure that the cams are set correctly. 4. Visually inspect basic board and capacitor for discoloration (burnt). (If present the board and/or capacitor must be replaced.) 5. Allow the motor to cool. 6. If these steps fail to correct or identify the problem, contact the Neles-Jamesbury Distributor or Representative in your area. 2. Motor runs, output drive will not turn. 1. Check that the manual override is fully engaged. Refer to IMO s listed below for OPTION Trouble Shooting: IMO-521 For Potentiometer option. IMO-519 For Heater and Thermostat option. IMO-520 For Limit Switch option. IMO-522 For 4-20mA Feedback Option.

7 7 9 ASSEMBLY DRAWING/SPARE PARTS ERA Spare Parts Item No Part Name Cover Assembly Cover Screws (8) O-ring Limit Switch Assembly Standard Basic Board Capacitor Assembly Override Shaft Brake Assembly

8 8 NOTES Jamesbury Inc. 640 Lincoln Street Box Worcester, Massachusetts USA Tel: Fax: Internet: Neles Controls Group A member of Rauma Corporation

LCR Series REVERSING ELECTRIC ACTUATORS. Installation, Maintenance and Operating Instructions

LCR Series REVERSING ELECTRIC ACTUATORS. Installation, Maintenance and Operating Instructions LCR Series REVERSING ELECTRIC ACTUATORS Installation, Maintenance and Operating Instructions IMO-I1262 11/2008 2 METSO AUTOMATION IMO-I1262 REV. 11/08 Table of Contents 1 GENERAL....................................

More information

Milwaukee's Electric Actuator Installation, Operation & Maintenance Manual

Milwaukee's Electric Actuator Installation, Operation & Maintenance Manual Milwaukee's Electric Actuator Installation, Operation & Maintenance Manual 1 Cover screws 9/64 Allen wrench. Terminal strip screws 1/8 wide flat head screw driver. Mounting pad screws 3/8 socket Cover

More information

Quarter Master Series 94 Actuator

Quarter Master Series 94 Actuator Quarter Master Series 94 Actuator Installation, Operation and Maintenance Manual Assembly Series 94 Manual Rev V 9/5/13 Page 1 of 12 Table of Contents Series 94 Electric Actuator Introduction... 3 Description...

More information

OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1

OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1 OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1 This instruction manual contains important information regarding the installation, operation, and troubleshooting of

More information

SUREPOWR TM SERIES -SURE 49 FIELD INSTALLATION INSTRUCTIONS

SUREPOWR TM SERIES -SURE 49 FIELD INSTALLATION INSTRUCTIONS SUREPOWR TM SERIES -SURE 49 FIELD INSTALLATION INSTRUCTIONS Safety First In the maintenance and operation of mechanical equipment, SAFETY is the basic factor which must be considered at all times. Through

More information

Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual

Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual For Use with: SNS4, SNS6, SNS10 & SNS15 Models Additional supplements may be needed for

More information

IMO -272 ISSUE 6/95 SERIES MBV, METAL-SEATED FLANGED BALL VALVES 3", 4" AND 6" CLASS 150 AND 300 STANDARD BORE, MB AND MC

IMO -272 ISSUE 6/95 SERIES MBV, METAL-SEATED FLANGED BALL VALVES 3, 4 AND 6 CLASS 150 AND 300 STANDARD BORE, MB AND MC IMO -7 ISSUE 6/95 SERIES MBV, METAL-SEATED FLANGED BALL VALVES 3", 4" AND 6" CLASS 50 AND 300 STANDARD BORE, MB AND MC INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS Table of Contents GENERAL........................

More information

Electric Actuator Installation, Operation & Maintenance Manual

Electric Actuator Installation, Operation & Maintenance Manual ICI Indelac Controls, Inc. Electric Actuator Installation, Operation & Maintenance Manual 6810 Powerline dr.-florence, Ky. 41042 - Telephone 859-727-7890, Tool free 800-662-9424 Fax. 859-727-4070, e-mail:

More information

Quarter Master Chief Series 92 Actuator

Quarter Master Chief Series 92 Actuator Quarter Master Chief Series 92 Actuator Installation, Operation and Maintenance Manual File: Series 92 O & M manual Rev. V 4/22/2013 Page 1 of 13 Table of Contents Series 92 Electric Actuator Introduction...

More information

Surepowr Series 100 Installation Manual

Surepowr Series 100 Installation Manual Surepowr Series 100 Installation Manual Safety First In the maintenance and operation of mechanical equipment, safety is the basic factor which must be considered at all times. Through the use of the proper

More information

Electric Modulating Actuator Installation, Operation & Maintenance Manual

Electric Modulating Actuator Installation, Operation & Maintenance Manual Electric Modulating Actuator Installation, Operation & Maintenance Manual For Use with: All Modulating AC Voltage Models Additional supplements may be needed for selected optional equipment including,

More information

12 Series Linear Electric Actuator Installation, Operation & Maintenance Manual

12 Series Linear Electric Actuator Installation, Operation & Maintenance Manual 12 Series Linear Electric Actuator Installation, Operation & Maintenance Manual TELEPHONE: +1-859-727-7890 TOLL FREE: +1-800-662-9424 FAX: +1-859-727-4070 E-MAIL: DVOGES@INDELAC.COM MROBINSON@INDELAC.COM

More information

Electric Actuator Installation, Operation & Maintenance Manual

Electric Actuator Installation, Operation & Maintenance Manual Electric Actuator Installation, Operation & Maintenance Manual For Use with: All Standard AC Voltage Models Additional supplements may be needed for selected optional equipment including, but not limited

More information

Surepowr Series Sure 150

Surepowr Series Sure 150 RCS Acutators Surepowr Series Sure 50 Installation Manual Safety First In the maintenance and operation of mechanical equipment, safety is the basic factor which must be considered at all times. Through

More information

Series 10 Actuator. Installation, Operation and Maintenance Manual

Series 10 Actuator. Installation, Operation and Maintenance Manual Series 10 Actuator Installation, Operation and Maintenance Manual File: series10.man Location: assembly/manual Rev.E 6/24/14 Page 1 of 8 Table of Contents Series 10 Electric Actuator Introduction... 3

More information

Installation Instructions

Installation Instructions WE-500 Series Electric Actuator Installation Instructions Introduction The WE-500 Series electric actuator is a rotary valve actuator with outputs of 500 in-lbs. It has been designed for NEMA 4, 4X and

More information

SUREPOWR TM SERIES -SURE 24/25 FIELD INSTALLATION INSTRUCTIONS

SUREPOWR TM SERIES -SURE 24/25 FIELD INSTALLATION INSTRUCTIONS SUREPOWR TM SERIES -SURE 4/5 FIELD INSTALLATION INSTRUCTIONS Safety First In the maintenance and operation of mechanical equipment, SAFETY is the basic factor which must be considered at all times. Through

More information

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation 12 Series Linear Actuators Operation & Maintenance Manual, Analog Positioner Installation 6810 POWERLINE DR.-FLORENCE, KY. 41042 - TELEPHONE 859-727-7890, TOLL FREE 1-800-662-9424 FAX. 859-727-4070, E-MAIL:

More information

PEAKTRONICS DMC-101 ADDITIONAL FEATURES. DC Motor Controller, 5A DMC-101

PEAKTRONICS DMC-101 ADDITIONAL FEATURES. DC Motor Controller, 5A DMC-101 PEAKTRONICS The Peaktronics DC Motor Controller is used for proportional positioning of actuators that use either DC motors or DC solenoids. The wide operating range of the (10 to 30 VDC and loads up to

More information

Cryogenic Wafer-Sphere Butterfly Valves

Cryogenic Wafer-Sphere Butterfly Valves Cryogenic Wafer-Sphere Butterfly Valves 3"-12" Installation, Maintenance and Operating Instructions IMO-16 4/2015 2 IMO-13 Table of Contents DESCRIPTION..................................... 3 Eccentric

More information

Radius, LLC Electric quarter turn actuator EW series Installation, Maintenance and Operating Manual

Radius, LLC Electric quarter turn actuator EW series Installation, Maintenance and Operating Manual Radius, LLC Electric quarter turn actuator EW series Installation, Maintenance and Operating Manual Models EW-880, 1400, 2100, 3100, 4400, 7000, 9700, 13000, 17000, 26500 EW-IMO-04 Radius, LLC 4922 Technical

More information

Electric Actuator Options & Accessories

Electric Actuator Options & Accessories The basic options and accessories listed in this section represent many of the most commonly used for electric actuation, factory configured to order on the actuation package. Contact Spears for any desired

More information

Product Description. Product Numbers. Warning/Caution Notations. Required Tools. Wiring. Prerequisites

Product Description. Product Numbers. Warning/Caution Notations. Required Tools. Wiring. Prerequisites Document No. 155-302N VE 598 Electronic Flowrite Valve Field Assembly Product Description The VE 598 Electronic Valve Assemblies consist of an electronic actuator, linkage kit, and a valve body assembly.

More information

AE Installation Operation & Maintenance Instructions

AE Installation Operation & Maintenance Instructions AE-1400 Installation Operation & Maintenance Instructions IMPORTANT Please read the installation operation and maintenance instruction prior to using any Jomar Valve component. Failure to follow the instructions

More information

Series 820 AWWA Butterfly Valves

Series 820 AWWA Butterfly Valves Series 820 AWWA Butterfly Valves Installation, Operation and Maintenance September 2015 SP-820-IOM-0915A Series 820 AWWA Butterfly Valves Installation, Operation and Maintenance Contents General.....3

More information

KT101 Series Governor System Installation Kit Cummins 4B(T) / 6B(T) With CAV/DPA Pump

KT101 Series Governor System Installation Kit Cummins 4B(T) / 6B(T) With CAV/DPA Pump KT101 Series Governor System Installation Kit Cummins 4B(T) / 6B(T) With CAV/DPA Pump 30 Years Strong! Introduction The KT101 Series Governor System Installation Kit provides the necessary brackets and

More information

Installation, Maintenance and Operation Manual

Installation, Maintenance and Operation Manual Installation, Maintenance and Operation Manual Radius, LLC 4922 Technical Drive Milford, MI 48381 Contents 1. Before operating actuator.. 3 2. About EW actuators 4 1) Internal & external component 2) Internal

More information

Thermal Shut-Off I. OVERVIEW OF THERMAL SHUT-OFF VALVES

Thermal Shut-Off I. OVERVIEW OF THERMAL SHUT-OFF VALVES Thermal Shut-Off Valve I. OVERVIEW OF THERMAL SHUT-OFF VALVES BI-TORQ Valve Automation thermal shut-off valves are designed for flow shutoff protection in piping systems handling flammable gasses, liquids,

More information

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual UniTorq UTQ 1.5 6.4 Quarter-Turn Actuator Installation and Operation Manual Thank you for purchasing our UTQ 1.5-6.0 Electric Actuators Before installation or operation of the actuator carefully review

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual HQ 005. ELECTRIC ACTUATORS QUARTER-TURN ELECTRIC ACTUATORS Installation, Operation and Maintenance Manual s Version Ver. 1 Revision Rev. 1 Document No. HKQI-611 Small & Compact Design High corrosion resistance

More information

Installation and Operating Manual

Installation and Operating Manual . Installation and Operating Manual WE/XE-690, 1350, 1700, 2640, 4400, 5200, 6900, 10500 17500, 25690 1 (Rev. 020113) IOM8011.docx . Table of Contents Introduction Page Safety Instructions..... 3 Introduction

More information

VALVCON. QX-Series ELECTRIC ACTUATORS. Installation, Maintenance and Operating Instructions

VALVCON. QX-Series ELECTRIC ACTUATORS. Installation, Maintenance and Operating Instructions VALVCON QX-Series ELECTRIC ACTUATORS Installation, Maintenance and Operating Instructions IMO-I3000 1/2014 2 IMO-I3000 Table of Contents 1 GENERAL.................................... 3 1.1 QX-Series Electric

More information

KT145 Series John Deere 6076 with Nippondenso Inj. Pump

KT145 Series John Deere 6076 with Nippondenso Inj. Pump KT145 Series John Deere 6076 with Nippondenso Inj. Pump 30 Years Strong! Introduction The KT145 Series Governor System Installation Kit provides the necessary brackets and hardware to install a GAC precise

More information

Installation Instructions

Installation Instructions Quick-Mount Visual Instructions for Quick-Mount Visual Instructions 1. Rotate the damper to its failsafe position. If the shaft rotates counterclockwise, mount the CCW side of the actuator out. If it rotates

More information

SAFE & SECURE ACTUATOR PRODUCT MANUAL

SAFE & SECURE ACTUATOR PRODUCT MANUAL INDELAC CONTROLS SAFE & SECURE ACTUATOR PRODUCT MANUAL Product Description: The Safe & Secure Series Actuator is a quarter turn Open/Close Actuator with Battery Backup Power ALL IN ONE! No more mounting

More information

LUF Series Unidirectional Electric Actuators

LUF Series Unidirectional Electric Actuators Installation, Maintenance and Operating Manual 9 Brookside Industrial Estate, Sawtry, Huntingdon, Cambridgeshire. PE28 5SB Tel: +44 (0) 1487 833080 Fax: +44 (0) 1487 833081 Email: sales@valvecontrol.co.uk

More information

HQ Series ¼ Turn Electric Actuator

HQ Series ¼ Turn Electric Actuator HQ Series ¼ Turn Electric Actuator Models HQ008 to HQ300 Operation and Installation Manual HQ Series Operation and Installation Manual 1 Table of Contents: General 1.0 Actuator Mounting 2.0 Power Requirements

More information

45 VALVE SERIES. 2-Position 4-Way 5-Ports, Installation & Service Instructions. Valve with Stem Operator, Installation & Service Instructions

45 VALVE SERIES. 2-Position 4-Way 5-Ports, Installation & Service Instructions. Valve with Stem Operator, Installation & Service Instructions (02/20/8) Pneumatic Division Richland, Michigan USA www.parker.com/pneumatics Document Number V275CP V280CP V284CP V32CP 45 VALVE SERIES Description 3-Position 4-Way 5-Ports, Installation & Service Instructions

More information

Type 1051 and 1052 Size 33 Diaphragm Rotary Actuator

Type 1051 and 1052 Size 33 Diaphragm Rotary Actuator Instruction Manual Type 1051 and 1052 Size 33 Diaphragm Rotary Actuator 1051 & 1052 Actuator Contents Introduction............................. 1 Scope of Manual........................... 1 Description................................

More information

Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual Series 70 Operation and Maintenance Manual TABLE OF CONTENTS 1. Definition of Terms............................................. 1 2. Safety................................................... 1 3. Storage..................................................

More information

Powers TM Controls EA 338 Electronic Actuator

Powers TM Controls EA 338 Electronic Actuator Powers TM Controls Technical Instructions Document No. 155-136P25 EA 338-1 Description Features 24 Vac power supply. The s are used with floor mount linkage kits to operate dampers in HVAC installations.

More information

VC-NR-100 SERIES STAINLESS STEEL, VERTICAL CANISTER PNEUMATIC ACTUATOR & SSBT SERIES CONTROL TOPS

VC-NR-100 SERIES STAINLESS STEEL, VERTICAL CANISTER PNEUMATIC ACTUATOR & SSBT SERIES CONTROL TOPS VC-NR-100 SERIES STAINLESS STEEL, VERTICAL CANISTER PNEUMATIC ACTUATOR & SSBT SERIES CONTROL TOPS BRADFORD VC-NR-100 SERIES ACTUATOR & CONTROL TOP FEATURES SPECIFICATIONS & DIMENSIONS FEATURES Excellent

More information

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited. SERVICE MANUAL ELECTRIC BRAISING PANS (30 & 40 GALLON) VE30 VE40 ML-126849 ML-126850 VE40 SHOWN - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used

More information

M Damper Mount Linkage Kit Installation. Item Description Quantity Item Description Quantity Nuts 2

M Damper Mount Linkage Kit Installation. Item Description Quantity Item Description Quantity Nuts 2 FANs 268.1, 1628.3 Installation Bulletin M9000-150 Issue Date 0796 M9000-150 Damper Mount Linkage Kit Installation 21 18 19 20 2 22 17 2 4 3 2 15.5 393.7 1 17 16 15 11 13 12 8 9 10 2 5 Note: Damper mount

More information

Installation Instructions

Installation Instructions Quick-Mount Visual Instructions for Mechanical Installation Quick-Mount Visual Instructions 1. Rotate the damper to its failsafe position. If the shaft rotates counterclockwise, mount the CCW side of the

More information

HQ Series ¼ Turn Electric Actuator

HQ Series ¼ Turn Electric Actuator HQ Series ¼ Turn Electric Actuator Models HQ004 and HQ006 Operation and Installation Manual HQ Series Operation and Installation Manual REV B 27-02-2012 1 Table of Contents: General 1.0 Actuator Mounting

More information

KT230 Series Caterpillar 3406 Governor System Installation Kit

KT230 Series Caterpillar 3406 Governor System Installation Kit KT230 Series Caterpillar 3406 Governor System Installation Kit 30 Years Strong! Introduction The KT230 Series Governor System Installation Kit provides the necessary brackets and hardware to install a

More information

VALVCON I-SERIES I6600 OPTION DN DEVICENET PROTOCOL

VALVCON I-SERIES I6600 OPTION DN DEVICENET PROTOCOL VALVCON I-SERIES I6600 OPTION DN DEVICENET PROTOCOL Installation, Maintenance and Operating Instructions IMO-I6600 1/2014 2 IMO-I6600 Table of Contents 1 GENERAL.................................... 3 1.1

More information

5000/6000 SERIES BALL VALVES INSTALLATION - MAINTENANCE MANUAL

5000/6000 SERIES BALL VALVES INSTALLATION - MAINTENANCE MANUAL Date: August 2011 / Page 1 of 6 5000/6000 SERIES BALL VALVES INSTALLATION - MAINTENANCE MANUAL DESIGN The design features three piece construction and a free floating ball allowing ease of maintenance

More information

V Series 115 VAC AND 230 VAC STANDARD ELECTRIC ACTUATORS. Installation, Maintenance and Operating Instructions

V Series 115 VAC AND 230 VAC STANDARD ELECTRIC ACTUATORS. Installation, Maintenance and Operating Instructions V Series 115 VAC AND 230 VAC STANDARD ELECTRIC ACTUATORS Installation, Maintenance and Operating Instructions IMO-I2100 11/2008 2 METSO AUTOMATION IMO-I2100 REV. 11/08 Table of Contents 1 GENERAL....................................

More information

IMO - 528EN Issue Date: 1/11

IMO - 528EN Issue Date: 1/11 IMO - 528EN Issue Date: / INSTALLATION, MAINTENANCE, AND OPERATING INSTRUCTIONS VALV-POWR VPVL MOD C VALUE-LINE DOUBLE-OPPOSED PISTON ACTUATORS Read entire instructions carefully before installation or

More information

ANDCO Eagle Actuator Instruction Manual

ANDCO Eagle Actuator Instruction Manual ANDCO Actuators ANDCO Eagle Actuator Instruction Manual The information contained in this manual is essential to safe, successful, long term operation of your Andco Eagle Linear Actuator. Read and follow

More information

Your Global Flow Control Partner. Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

Your Global Flow Control Partner. Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual Your Global Flow Control Partner Series 70 Table of Contents 1. Definition of Terms.......................................2 2. Safety............................................. 2 3. Storage............................................2

More information

Small Motorized Actuator

Small Motorized Actuator R Small Motorized Actuator INSTRUCTION MANUAL INDEX INTRODUCTION STANDARD SPECIFICATIONS EXTERNAL DIMENSIONS PRECAUTIONS DURING INSTALLATION ADJUSTMENT TRIAL OPERATION PRECAUTIONS BEFORE SERVICE MAINTENANCE

More information

SERVICE MANUAL for. Engine-to-Generator. Part Number used on. John Deere Engine Driven Aircraft Ground Power Single-Bearing Generator Sets

SERVICE MANUAL for. Engine-to-Generator. Part Number used on. John Deere Engine Driven Aircraft Ground Power Single-Bearing Generator Sets TO-216 SERVICE MANUAL for Engine-to-Generator FLEXIBLE COUPLING Part Number 181267 used on John Deere Engine Driven Aircraft Ground Power Single-Bearing Generator Sets manufactured by HOBART BROTHERS COMPANY

More information

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service Installation Instructions VA-908x Code No. LIT-12011566 Issued August 24, 2009 Applications The VA-908x Series Electric

More information

Tooling Assistance Center

Tooling Assistance Center Safeguards are designed into this application equipment to protect operators and maintenance personnel from most hazards during equipment operation. However, certain safety precautions must be taken by

More information

I-BFV.KIT Butterfly Valve Gear Operator Replacement

I-BFV.KIT Butterfly Valve Gear Operator Replacement SERIES 5, 05,, and 0C WARNING Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before

More information

Flow Line Controls. Installation & Operations Manual SERIES 20/21 Pneumatic Actuators

Flow Line Controls. Installation & Operations Manual SERIES 20/21 Pneumatic Actuators Flow Line Controls Installation & Operations Manual SERIES 20/21 Pneumatic Actuators Flow Line Controls, Inc. P.O. Box 677 Schriever, LA 70395 Phone: 985-414-6003 Toll Free 1-800-815-9226 Fax 985-414-6072

More information

RE Generation II Troubleshooting Guide Section I Preliminary Information and Evaluation

RE Generation II Troubleshooting Guide Section I Preliminary Information and Evaluation DODGE ENGINEERING & CONTROLS, INC. 196 Riverneck Road Chelmsford, MA 01824 PHONE (978) 244-1200 FAX (978) 244-1422 TOLL FREE (877) 334-2875 RE Generation II Troubleshooting Guide Section I Preliminary

More information

B21 Series BASOTROL Gas Valve

B21 Series BASOTROL Gas Valve Installation Instructions B21 Issue Date September 19, 2017 Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing BASO Gas Products. Carefully

More information

PRODUCT INFORMATION BULLETIN #3365 DIGITAL MOTOR CONTROL PLATTER SYSTEMS For Serial Number and After

PRODUCT INFORMATION BULLETIN #3365 DIGITAL MOTOR CONTROL PLATTER SYSTEMS For Serial Number and After PRODUCT INFORMATION BULLETIN #3365 DIGITAL MOTOR CONTROL PLATTER SYSTEMS For Serial Number 28640996 and After Record Platter System Identification Numbers Here: Model # Serial # Table of Contents Program

More information

Wafer-Sphere 14" 20" Butterfly Valve. Installation, Maintenance and Operating Instructions

Wafer-Sphere 14 20 Butterfly Valve. Installation, Maintenance and Operating Instructions Wafer-Sphere 14" 20" Butterfly Valve Installation, Maintenance and Operating Instructions IMO-15 2/2015 2 IMO-15 Table of Contents DESCRIPTION..................................... 3 Eccentric Shaft Design

More information

Series 72 Electri-SAFE On/Off Operation Including CLC Option Installation, Operation and Maintenance Instructions

Series 72 Electri-SAFE On/Off Operation Including CLC Option Installation, Operation and Maintenance Instructions WCAIM2049 (Part 18960) Series 72 Electri-SAFE On/Off Operation Including CLC Option Installation, Operation and Maintenance Instructions Series 72 actuators are electro-hydraulic quarterturn valve actuators.

More information

SD Bendix ET-2 Electronic Treadle DESCRIPTION OPERATION

SD Bendix ET-2 Electronic Treadle DESCRIPTION OPERATION SD-15-4106 Bendix ET-2 Electronic Treadle PIVOT SPRING MOUNTING BASE DESCRIPTION CONNECTOR FIGURE 1 - ET-2 ELECTRONIC TREADLE ROLLER TREADLE COVER DOUBLE RETURN SPRING CABLE ASSEMBLY The ET-2 is an electronic

More information

AF-17 Electronic Positioner Installation, Operation and Maintenance Instructions

AF-17 Electronic Positioner Installation, Operation and Maintenance Instructions WCAIM2031 AF-17 Electronic Positioner Installation, Operation and Maintenance Instructions MODELS 20 For AF-17 Boards Mounted Inside 10-23 75 Actuator. 30 For AF-17 Boards Mounted Inside 25-30 75 Actuator.

More information

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service Technical Bulletin Code No. LIT-977325 Issued August 24, 2009 Supersedes May 29, 2007 Introduction..........................................................

More information

REACTOR DISCHARGE VALVES S & DIGESTER BLOW VALVES SB & 5300SB B FLANGED BALL VALVES

REACTOR DISCHARGE VALVES S & DIGESTER BLOW VALVES SB & 5300SB B FLANGED BALL VALVES REACTOR DISCHARGE VALVES 8-12 530S & 5300 6-10 6300 DIGESTER BLOW VALVES 8-12 530SB & 5300SB 6-10 6300B FLANGED BALL VALVES Installation, Maintenance and Operating Instructions IMO-295 EN 11/2017 2 IMO-302

More information

ICI Indelac Controls, Inc. Installation, Operation & Maintenance Manual For Electric Spring Return Actuator

ICI Indelac Controls, Inc. Installation, Operation & Maintenance Manual For Electric Spring Return Actuator ICI Indelac Controls, Inc. Installation, Operation & Maintenance Manual For Electric Spring Return Actuator 6810 Powerline Dr. Florence, Ky. 41042 Telephone 859-727-7890, Tool free 800-662-9424, Fax. 859-727-7-4070,

More information

JT SERIES ANGLE STEM TANK BOTTOM BALL VALVE DN25 DN150. Installation, Maintenance and Operating Instructions

JT SERIES ANGLE STEM TANK BOTTOM BALL VALVE DN25 DN150. Installation, Maintenance and Operating Instructions JT SERIES ANGLE STEM TANK BOTTOM BALL VALVE DN25 DN150 Installation, Maintenance and Operating Instructions IMO-235 EN 3/2019 2 IMO-235 EN TABLE OF CONTENTS 1. GENERAL... 3 1.1 Scope of the Manual... 3

More information

VG7000 Valve Linkage for M100 Series Motor Actuators

VG7000 Valve Linkage for M100 Series Motor Actuators Valve and Actuator Manual 977 Actuators and Positioners Section Technical Bulletin VG7000 Series Issue Date 1295 VG7000 Valve Linkage for M100 Series Motor Actuators lntroduction 3 Application Details

More information

VALVCON V-Series ELECTRIC ACTUATORS 115 VAC AND 230 VAC With Iso/Readback Board Installed (Option U )

VALVCON V-Series ELECTRIC ACTUATORS 115 VAC AND 230 VAC With Iso/Readback Board Installed (Option U ) VALVCON V-Series ELECTRIC ACTUATORS 115 VAC AND 230 VAC With Iso/Readback Board Installed (Option U ) Installation, Maintenance and Operating Instructions IMO-I5500 EN 10/2017 2 IMO-I5500 EN TABLE OF CONTENTS

More information

Fisher 657 Diaphragm Actuator Sizes and 87

Fisher 657 Diaphragm Actuator Sizes and 87 Instruction Manual 657 Actuator (30-70 and 87) Fisher 657 Diaphragm Actuator Sizes 30 70 and 87 Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 2 Installation... 3 Mounting

More information

VALVCON V-Series ELECTRIC ACTUATORS 115 VAC AND 230 VAC. Installation, Maintenance and Operating Instructions

VALVCON V-Series ELECTRIC ACTUATORS 115 VAC AND 230 VAC. Installation, Maintenance and Operating Instructions VALVCON V-Series ELECTRIC ACTUATORS 115 VAC AND 230 VAC Installation, Maintenance and Operating Instructions IMO-I2100EN 9/2017 2 IMO-I2100 EN TABLE OF CONTENTS 1. GENERAL... 3 1.1 Scope of the Manual...

More information

VALV-POWR VALUE-LINE DOUBLE-OPPOSED PISTON ACTUATORS MODEL A. Installation, Maintenance and Operating Instructions

VALV-POWR VALUE-LINE DOUBLE-OPPOSED PISTON ACTUATORS MODEL A. Installation, Maintenance and Operating Instructions VALV-POWR VALUE-LINE DOUBLE-OPPOSED PISTON ACTUATORS MODEL A Installation, Maintenance and Operating Instructions IMO-529 EN /208 2 IMO-529 EN TABLE OF CONTENTS. GENERAL... 3 2. TECHNICAL DATA... 3 3.

More information

INSTRUCTION MANUAL. Anchor Darling 1878 Swing Check Valves. Installation Operation Maintenance. Sizes 1/2 through 2 FCD ADENIM

INSTRUCTION MANUAL. Anchor Darling 1878 Swing Check Valves. Installation Operation Maintenance. Sizes 1/2 through 2 FCD ADENIM INSTRUCTION MANUAL Anchor Darling 1878 Swing Check Valves Sizes 1/2 through 2 Installation Operation Maintenance FCD ADENIM0006-00 Table of Contents 1.0 Physical Description and Operation of Equipment

More information

Electronic Proportional (EP) Control for Heavy Duty Series 2 Piston Pumps Model 33

Electronic Proportional (EP) Control for Heavy Duty Series 2 Piston Pumps Model 33 Electronic Proportional (EP) Control for Heavy Duty Series 2 Piston Pumps Model 33 Model 39 Model 46 Model 54 Model 64 EP Control for Heavy Duty Series 2 Piston Pumps Table of Contents Introduction........................................................................

More information

TOYOTA TUNDRA TVIP V4 Preparation

TOYOTA TUNDRA TVIP V4 Preparation Preparation Part Number: PT398-00100 PT398-00100-AA Conflicts Do not install into vehicles without RKE system. Recommended Sequence of Application Item # Accessory 1 TVIP/RES Any TVIP or RES system 2 XM

More information

Y20EBA Linkage Kit, M100 to Barber-Colman 1/2 to 1-1/4 Inch Valves

Y20EBA Linkage Kit, M100 to Barber-Colman 1/2 to 1-1/4 Inch Valves Installation Sheets Manual 121 Also in FANs 977, 628.1 Technical Bulletin Issue Date 0893 Y20EBA Linkage Kit, M100 to Barber-Colman 1/2 to 1-1/4 Inch Valves lntroduction 2 Application Details *2 Glossary

More information

GH-BETTIS OPERATING & MAINTENANCE INSTRUCTIONS DISASSEMBLY & ASSEMBLY FOR THE T80X-M4-S DOUBLE ACTING SERIES HYDRAULIC ACTUATORS

GH-BETTIS OPERATING & MAINTENANCE INSTRUCTIONS DISASSEMBLY & ASSEMBLY FOR THE T80X-M4-S DOUBLE ACTING SERIES HYDRAULIC ACTUATORS GH-BETTIS OPERATING & MAINTENANCE INSTRUCTIONS DISASSEMBLY & ASSEMBLY FOR THE T80X-M4-S DOUBLE ACTING SERIES HYDRAULIC ACTUATORS -S INDICATES CYLINDERS ARE IN TANDEM PART NUMBER: 100121 REVISION "A" ECN

More information

SERIES 73 ELECTRIC ACTUATOR OPERATION AND MAINTENANCE MANUAL. The High Performance Company

SERIES 73 ELECTRIC ACTUATOR OPERATION AND MAINTENANCE MANUAL. The High Performance Company SERIES 73 ELECTRIC ACTUATOR OPERATION AND MAINTENANCE MANUAL The High Performance Company Table Of Contents: page Safety instructions: Definitions of Terms... 2 Introduction principle of operation...

More information

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX: TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: +353 66 7121911 FAX: +353 66 7124503 e-mail: sales@tillotson.ie HU SERIES SERVICE MANUAL INTRODUCTION To keep apace of new market

More information

COMMERCIAL. BV & BVM Series Installation Instructions 06/29/15

COMMERCIAL. BV & BVM Series Installation Instructions 06/29/15 COMMERCIAL Bray Controls Commercial Division 13788 West Road, Suite 00A Houston, Texas 77041 BCDSales@Bray.com Phone: 1-888-41-79 Fax: 1-888-41-70 www.braycommercialdivision.com BV & BVM Series Installation

More information

V Series. 115 VAC AND 230 VAC STANDARD ELECTRIC ACTUATORS With Isolated Control/Position Feedback Board Installed (Option U )

V Series. 115 VAC AND 230 VAC STANDARD ELECTRIC ACTUATORS With Isolated Control/Position Feedback Board Installed (Option U ) V Series 115 VAC AND 230 VAC STANDARD ELECTRIC ACTUATORS With Isolated Control/Position Feedback Board Installed (Option U ) Installation, Maintenance and Operating Instructions IMO-I5500 11/2008 2 METSO

More information

ECON ELECTRIC ACTUATOR Fig ELA60 Ex

ECON ELECTRIC ACTUATOR Fig ELA60 Ex ECON ELECTRIC ACTUATOR Fig. 7907, type ELA60 Fig. 7907 ELA60 IP67 (optionally IP68) Fig. 7907 ELA60 Ex EX ǁ 2G Ex d IIB T4 Gb Small & Compact quarter turn actuator Mechanical position indicator High output

More information

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS 5 Swift Lock Ready Shape Tree (Patent Pending) Instructions IMPORTANT SAFETY INSTRUCTIONS When using electrical products, basic precautions should always be followed including the following: READ AND FOLLOW

More information

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS 7.5 Swift Lock Ready Shape Tree (Patent Pending) Instructions IMPORTANT SAFETY INSTRUCTIONS When using electrical products, basic precautions should always be followed including the following: READ AND

More information

IOM Manual. IOM Manual. Series 20/21.

IOM Manual. IOM Manual. Series 20/21. IOM Manual IOM Manual Series 20/21 www.flowlinevalves.com Flow Line Valve and Controls, L.L.C. 110 Main Project Road Schriever, LA 70395 P.O. Box 677 Schriever, LA 70395 Phone 985-414-6004 * Toll Free

More information

Valtek Position Pac GENERAL INFORMATION INSTALLATION INSTRUCTIONS OPERATION. Valtek Linear Actuators

Valtek Position Pac GENERAL INFORMATION INSTALLATION INSTRUCTIONS OPERATION. Valtek Linear Actuators Valtek Position Pac GENERAL INFORMATION The following instructions are designed to assist with installing, calibrating and troubleshooting the Valtek Position Pac valve position indicator. Product users

More information

Technical Specification. RCS Electric Actuators with a ProfiBus Field Control and Communication Module

Technical Specification. RCS Electric Actuators with a ProfiBus Field Control and Communication Module The following specification defines the minimum requirements for the supply of motor operated valve actuators with a field communication bus system for remote control. The complete system shall consist

More information

Electronic Proportional (EP) Control for Medium Duty Piston Pumps

Electronic Proportional (EP) Control for Medium Duty Piston Pumps Electronic Proportional (EP) Control for Medium Duty 72400 Piston Pumps EP Control for Medium Duty 72400 Piston Pumps Table of Contents Introduction........................................................................

More information

BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL

BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL TABLE OF CONTENTS SYSTEM...... Warning........ Description...... Prior to Operation OPERATION... Main Components... Mechanical...

More information

Boston Gear LOR Series

Boston Gear LOR Series Boston Gear LOR Series Trig-O-Matic Lite Overload Release Clutch Installation and Maintenance Instructions Doc. No. LOR Series Trig-O-Matic Lite www.bostongear.com LOR SERIES TRIG-O-MATIC LITE OVERLOAD

More information

MODEL ELC-12/40-CVM-D BATTERY CHARGER

MODEL ELC-12/40-CVM-D BATTERY CHARGER NATIONAL RAILWAY SUPPLY MODEL ELC-12/40-CVM-D BATTERY CHARGER Installing, Operating and Service Instructions for the ELC-12/40-CVM-D Solid State Charger PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING

More information

Valtek Auxiliary Handwheels and Limit Stops

Valtek Auxiliary Handwheels and Limit Stops Valtek Auxiliary s and Limit Stops Table of Contents Page 1 General information 2 Installation 2 Side-mounted handwheels, size 25 and 50 (linear actuators) 3 Side-mounted handwheels, size 100 and 200 (linear

More information

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual Manual No. 5AOP-OM1-2 Val-Matic Air / Oil Hydraulic Panel Pump Control System Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION...

More information

EasyStart 364 (ASY-364-X20-IP) Installation Instructions for the Coleman / Airxcel Air Conditioners

EasyStart 364 (ASY-364-X20-IP) Installation Instructions for the Coleman / Airxcel Air Conditioners EasyStart 364 (ASY-364-X20-IP) Installation Instructions for the Coleman / Airxcel Air Conditioners using Installation Kit KIT-364-CM1 Contents Introduction... 2 Safety first... 2 Making a good crimp...

More information

66 CHAPTER FOUR. Spark Plug Removal Refer to Figure 28 for spark plug wive routing according to engine.

66 CHAPTER FOUR. Spark Plug Removal Refer to Figure 28 for spark plug wive routing according to engine. 66 CHAPTER FOUR IGNITION SYSTEM A mechanical contact breaker point ignition system is used on all engines covered in this manual. The ignition system may use a Delco-Remy, Autolite, Mallory or Prestolite

More information

IOM Manual. IOM Manual. Series 76/77.

IOM Manual. IOM Manual. Series 76/77. IOM Manual IOM Manual Series 76/77 www.flowlinevalves.com Flow Line Valve and Controls, L.L.C. 110 Main Project Road Schriever, LA 70395 P.O. Box 677 Schriever, LA 70395 Phone 985-414-6004 * Toll Free

More information

EW 350 ELECTRIC ACTUATOR INSTALLATION, MAINTENANCE AND OPERATION MANUAL

EW 350 ELECTRIC ACTUATOR INSTALLATION, MAINTENANCE AND OPERATION MANUAL RADIUS EW 350 EW 350 ELECTRIC ACTUATOR INSTALLATION, MAINTENANCE AND OPERATION MANUAL 2/6 Instruction Manual Thank you for purchasing our EW series electric actuator! For safe and proper operation, please

More information