Electrical panels TECHNICAL INFORMATION 104 ELECTRICAL PANELS 105 PROTECTION OF ELECTRICAL COMPONENTS 107 ELECTRICAL PANEL ACCESSORIES 110

Size: px
Start display at page:

Download "Electrical panels TECHNICAL INFORMATION 104 ELECTRICAL PANELS 105 PROTECTION OF ELECTRICAL COMPONENTS 107 ELECTRICAL PANEL ACCESSORIES 110"

Transcription

1 04 ELECTRICAL PANELS Electrical panels TECHNICAL INFORMATION 104 ELECTRICAL PANELS 105 PROTECTION OF ELECTRICAL COMPONENTS 107 ELECTRICAL PANEL ACCESSORIES

2 TECHNICAL INFORMATION Technical information Front mounted timer to facilitate programming,, All wires are capped, Connection terminals for the mains, Connection of the transformer secondary via a fuse holder, The cabinets are delivered with rigid cable glands as standard, Removable mounting bracket to facilitate installation, Over-sized transformer to avoid overheating phenomena, Careful, colour coded wiring, Cabinet mounting screws and bushings are enclosed, Appropriate wire cross section (2.5 mm² for the power unit), Two seals, one on the glass door, and one on the cover. May be recessed into the wall. LED indicator lights R TEMP automatic regulation Circuit breaker to protect the filtration pump Bipolar circuit breaker 6.-10A to protect the booster pump The electrical panel is equipped with a mounting bracket to facilitate installation and hold the electrical panel away from the wall to prevent water from infiltrating into the panel by capillary action. Recommended cable cross section according to the distance in metres from the underwater light (12 V power supply) Cable cross section mm² for one 300 W underwater light from to M 2.1 M M 3.2 M M 5.3 M M 8.5 M Cable cross section in mm² for one 25 W underwater light from to Cable with 2 wires (no yellow/ green wire) M 10 M M 16 M M 26 M M 38 M PROCOPI uses a 700VA transformer to run two 300W underwater lights (under 12V) instead of 630VA transformers. The decision to use a 700VA transformer instead of a 630VA transformer provides for a greater power reserve, this helps prevent the transformer from running hot and so helps limit heating within the electrical panel cabinet. 104 BWT CONSTRUCTION & RENOVATION

3 ELECTRICAL PANELS BWT ENERGY SAVING FILTRATION CONTROL PANELS - SWIMLINE Family 1900 Automatic regulation: R-TEMP Automatic regulation of the filtration cycle based on the water temperature can reduce your pool s energy consumption by up to 40%. Swimline electrical panels that feature automatic regulation of the length of the filtration cycle as a function of water temperature share the same characteristics as the standard Swimline electrical panel except that the programmable timer is replaced by a programmable logic controller with a new optimal algorithm. Calculation fof the length of the filtration cycle Calcul de la durée de filtration Duration of the filtration cycle in hours/ days Durée de filtration en heures / jour Automatic regulation comprises: A programmable logic controller, A manual over-ride to force the device on, A temperature sensor with a 6m cable, A titanium thermowell that is mounted on a reducing tee,1/2, or a saddle clamp. PROCOPI TOP TIP Depending on the region where the pool is installed, and/ or the quality of the electrical supply to the pool (end of line), it may be necessary to protect the pool s electrical installation and thus the properties of the circuit boards and components equipping the various devices. Protection accessories are listed on p X Circuit breaker 2 1 TO 1.6 A TO 2.5 A TO 4 A 5 4 TO 6.3 A TO 10 A 7 9 TO 14 A In order to select the appropriate circuit breaker, simply replace the letter X, with the number corresponding to the required rating ELECTRICAL PANELS Température Water de temperature l'eau en in C The circuit breaker rating must be greater than the maximum current consumed by the filtration pump. The maximum currents drawn by the pumps are set out in the pump chapter in this catalogue. Code Reference Description Price 6601X0 RTEMP+CFB-1 Filtration electrical panel RTEMP 6604X0 RTEMP+CFP-050 Filtration electrical panel RTEMP, for one 50 W or LED underwater light 6609X0 RTEMP+CFP-100 Filtration electrical panel RTEMP, for two 50 W or LED underwater lights BWT CONSTRUCTION & RENOVATION 105

4 ELECTRICAL PANELS Each or our electrical panels is made of top quality components carefully selected on the basis of their excellent performance data. The injected resin casings were purpose designed to satisfy the requirements of pool builders and pool users. Electrical panels come with a wall mounting bracket and a suitably rated circuit breaker. They comply with the electrical safety standard NF and the EMC safety standards NF and NF BWT FILTRATION ELECTRICAL PANEL - SWIMLINE Family 1900 Protection rating, IP55, Two levels of watertight protection : an o-ring on the cover, an o-ring on the plexi-glass door, Hinge mounted reversible smoked plexi-glass door, All the controls are protected behind the plexi-glass door, Rocker switches, Indicator lights (LEDs), Delivered with a circuit breaker, up to 14 Amp, Terminal block to facilitate connection, Generously proportioned for easy wiring, A wall mounting bracket is enclosed. X Circuit breaker PROCOPI TOP TIP 2 1 TO 1.6 A TO 2.5 A TO 4 A 5 4 TO 6.3 A TO 10 A 7 9 TO 14 A In order to select the appropriate circuit breaker, simply replace the letter X, with the number corresponding to the required rating The circuit breaker rating must be greater than the maximum current consumed by the filtration pump. The maximum currents drawn by the pumps are set out in the pump chapter in this catalogue. BWT ELECTRONIC LEVEL CONTROLLER WITH HYDROSTATIC SENSOR Code Reference Description Price 6600X0 CFB-1 Filtration or automatic cleaner electrical panel Automatic cleaner electrical panel -CFB-1/ 10A 6603X0 CFP-050 FIltration electrical panel with transformer for 1 50W or LED underwater light 6608X0 CFP-100 FIltration electrical panel with transformer for 2 50W or LED underwater lights 6600X1 CFB-1 / BA FIltration electrical panel with automatic cleaner option 6603X1 CFP-050 / BA Filtration ctrl panel, with transfo. for 1 50 W or LED underwater light, with automatic cleaner option 6608X1 CFP-100 / BA Filtration ctrl panel, with transfo. for 2 50 W or LED underwater lights, with automatic cleaner option This device can control multiple water levels using a single hydrostatic sensor. 6 water level values can be entered into the programmable logic controller. This makes the level controller particularly suitable for controlling levels in a buffer tank. TH : Very high limit / H : High limit / FR : End filling limit / DR : Begin filling limit / B : Low limit / TB : Very low limit The level value can be read off the PLC screen. The sensor is simply positioned at the bottom of the water volume to be controlled. Measurements are not falsified by material agglomerates, fluctuations of the water s electrical properties or by the shape of the reservoir. Extremely reliable. Standard cable length is 10 m. Operating range: 0.10 m to 3.00 m Buffer tank electronic controller (hydrostatic sensor and an electrovalve) Buffer tank electronic controller with 10 to 40 m cable (hydrostatic sensor and an electrovalve) The client should specify the required cable length on placing the order. The maximum cable length is 40m. 106 BWT CONSTRUCTION & RENOVATION

5 ELECTRICAL PANELS BWT LEVEL REGULATION - SWIMLINE Family RED-1: Pool level regulation electrical panel, comprising an adjustable level sensor, timer, brass 20/27 electric valve. Protected by a fuse. RED-2: Balance tank regulation electrical panel comprising 5 stainless steel sensors (ground, pump shut down, electrovalve open and close, overflow safety). and a brass electrovalve 20/ 27. Protected by a fuse. Code Reference Description Price RED-1 Electronic pool level controller, with electric valve RED-2 Balance tank level controller (with 5 stainless steel sensors and 1 electric valve) ELECTRICAL PANELS BWT MULTI-FUNCTION ELECTRICAL PANEL Family 1900 The multi-function electrical panel can control and or/ power multiple devices simultaneously. The electrical panel is available in 3 versions, to adapt to the power of the filtration pump. However, the panel only runs in single phase mode. Functions: Manages filtration cycles: Takes control of the pump in manual and automatic mode (with timer). Controls the booster pump: Controls the booster pump in manual and automatic mode (with timer). Electrical supply and command of the underwater ights: Features a swtich to turn the lights on and off. 16 A socket on the outside of the electrical panel. Protected outgoing line to power the automatic cover electrical panel (*). Protected outgoing line to power a water treatment device: electrolyser, controller, UV bulb,etc. (*). Protected outgoing line to power an additional ph pump, etc. (*). Multi-function electrical panel: 230VAC 1ph power supply, maximum current 53A, IP44, residual current device 30mA. Filtration function: 230VAC 1ph power supply. Panel fitted with an adjustable circuit breaker with 3 protection ratings to choose from 2.5-4A, 4-6.3A, A (The maximum current of the pump should not exceed 9A). Booster pump function: 230VAC 1ph power supply. Panel fitted with an adjustable circuit breaker A (The maximum current of the pump should not exceed 9A). Electrical supply and command of the underwater ights: 12VAC power supply with two 50VA outgoing lines. Compatible with LED lighting. 16 A socket: 230VAC 16A Protected outgoing line to power the automatic cover electrical panel. 230VAC 1ph power supply. Fitted with an adjustable circuit breaker A. rotected outgoing line to power a water treatment device. 230VAC 1ph power supply. Fitted with an adjustable circuit breaker A Protected outgoing line to power an additional ph pump, etc.: 230VAC 1ph power supply. Fitted with an adjustable circuit breaker A. NEW Electrical panels for automatic covers are listed on page Multifunction electrical panel for 1ph pump 2.5 to 4A Multifunction electrical panel for 1ph pump 4 to 6.3A Multifunction electrical panel for 1ph pump 6.3 to 10A Depending on the region where the pool is installed, and/ or the quality of the electrical supply to the pool (end of line), it may be necessary to protect the pool s electrical installation and thus the properties of the circuit boards and components equipping the various devices. Protection accessories are listed on p. 111 BWT CONSTRUCTION & RENOVATION 107

6 ELECTRICAL PANELS BWT FILTRATION ELECTRICAL PANEL - SR LIGHT Family 1920 Hinge mounted door, All the controls are mounted behind a protective plexi-glass door (no controls on the outside), Rocker switches, Delivered with a circuit breaker up to 14A, Delivered with the necessary bushings, screws and cable glands, All our electrical panels are fitted with a suitably rated thermo-magnetic circuit breaker. PROCOPI TOP TIP X Circuit breaker 2 1 TO 1.6 A TO 2.5 A TO 4 A 5 4 TO 6.3 A TO 10 A 7 9 TO 14 A In order to select the appropriate circuit breaker, simply replace the letter X, with the number corresponding to the required rating The circuit breaker rating must be greater than the maximum current consumed by the filtration pump. The maximum currents drawn by the pumps are set out in the pump chapter in this catalogue. Each or our electrical panels is made of top quality components carefully selected on the basis of their excellent performance data. The injected resin casings were purpose designed to satisfy the requirements of pool builders and pool users. Electrical panels come with a wall mounting bracket and a suitably rated circuit breaker. Swimline electrical panels are fitted with inidcator lights and top of the line components. They comply with the electrical safety standard NF and the EMC safety standards NF and NF Code Reference Description Price 6700X0 SRF-1 Filtration of automatic cleaner electrical panel 6703X0 SRF-050 FIltration electrical panel with transformer for one 50 W or LED underwater light 6708X0 SRF-100 FIltration electrical panel with transformer for two 50 W or LED underwater lights Other electrical panels and options SRF-1/10A Automatic cleaner electrical panel Entrapment alarm electrical panel with siren and pressure switch In order to select the appropriate circuit breaker, simply replace the letter X, with the number corresponding to the required rating. BWT LEVEL REGULATION - SR LIGHT Family Code Ref Description Price RED-1 Electronic pool level controller, with electric valve RED-2 Balance tank level controller (with 5 SS sensors and 1 electric valve) Balance tank level controller (with 5 SS sensors RED-2-SEV and no electric valve) 108 BWT CONSTRUCTION & RENOVATION

7 PROTECTION OF ELECTRICAL COMPONENTS More and more of the equipment on our market is equipped with electronic circuit boards and/or components intended to simplify their operation and achieve the ergonomics demanded by the consumer. It is, however, clear that the quality of the electrical supply varies, depending on the region and the area, generating under and over voltages. In addition, some areas are prone to storms and lightning strikes. Obviously, both of these phenomena can cause damage to electronic components: the professional has to deal with failures and after sales services and the end user is unhappy. To avoid this type of situation, it is necessary to install devices designed to protect the electronic components equipping the various items of pool equipment. In some countries, France included, insurance companies and the government body charged with approval of electrical installations for connection to the power grid demand the installation of protection equipment. Procopi s technicians are available to provide advice on these subjects and suggest articles to meet the various requirements. ELECTRICAL PANELS LIGHTNING ARRESTERS Family 2000 Overvoltages triggered by lightning strikes. A lightning arrester is a device designed to protect electrical equipment against transient overvoltages triggered notably by lightning strikes. This type of device is necessary to protect equipment fitted with electronic components. The lightning arrester must be installed by a professional in parallel with the main circuit and no more than 30 metres distant from the equipment it is meant to protect. Lightning arrerter, 1ph Lightning arrester, 3ph Lightning arrester for three phase + neutral power supply Lightning arrester for single phase power supply SUPERVISION RELAYS Family 2000 Over and under voltages associated with grid fluctuations. Automatic operation Timed reset Operating indicators Easily installed on a DIN rail NF EN compliant This type of device is necessary to protect equipment fitted with electronic components. The relay is connected in parallel with the supply of the primary circuit. The same device may be used irrespective of the power of the equipment. For a three phase + neutral installation, you will need three supervision relays (one for each live). Each relay should be connected between phase and neutral. As soon as the voltage falls below or rises above the operating range of VAC, the relay opens the circuit, thus protecting the installation Supervision relay, low voltage, 230 V ACCESSPRO 109

8 ELECTRICAL PANEL ACCESSORIES TRANSFORMERS Family Toroidal transformer 230V/12 V 50 VA (Swimline-SR-Light) Toroidal transformer 230V/12 V 100 VA (Swimline-SR-Light) Toroidal transformer 230V/12 V 315 VA (Swimline, SR-Light) Toroidal transformer 230V/12 V 700 VA (Swimline, SR-Light) FROSTAT AND ENTRAPMENT ALARM Family 1900 Frostat electrical panel Frostat electrical panel Entrapment alarm electrical panel Entrapment alarm electrical panel with siren and pressure switch additional pressure switch XMLB004A1S11 TWO COMPONENT GEL Family Two component gel, 500 ml The two component gel insulates the connections inside the connection boxes. Protection rating: IP68 Cure time: approx 15 minutes at 25 C. The gel can be easily removed to allow for interventions on the connections. ACCESSORIES Family Timer without backup power (SR-Light - Swimline Electrical panel) Timer without backup power (to be built in) Timer without backup power (modular) Timer with backup power (SR-Light - Swimline Electrical panel) Timer with backup power (to be built in) Thermal magnetic circuit breaker, A Thermal magnetic circuit breaker, A Thermal magnetic circuit breaker, A Thermal magnetic circuit breaker, A Thermal magnetic circuit breaker, A Thermal magnetic circuit breaker, A Filtration electrical panel 230V contactor Heating electrical panel 230V contactor Back-up power: allows the timer to continue to run in the event of a power outage. 110 ACCESSPRO

9 ELECTRICAL PANEL ACCESSORIES CIRCUIT BREAKERS AND SWITCHES Family 2000 Differential circuit breaker - type AC A differential circuit breaker detects differences in the strength of the current measured on the phase line and the current returned to the neutral line. It provides protection for people, but alone, it cannot provide protection against power surges. The French safety standard NF C requires installation of a 30mA differential circuit breaker for swimming pool applications. AC type circuit breakers provide adequate protection for most circuits. 1 C curve circuit breakers Circuit breakers provide protection against power surges and short circuits. C curve circuit breakers are most commonly used (protection of circuits supplying socket outlet, lighting, etc.. D curve circuit breakers D curve circuit breakers perform the same role as D curve circuit breakers except that they accept a higher inrush current when the motor starts (heat pump, pump, etc. ). 2 ELECTRICAL PANELS 1 Circuit breakers, C curve Bipolar circuit breaker, C curve, 6A Bipolar circuit breaker, C curve, 8A Bipolar circuit breaker, C curve, 10A Bipolar circuit breaker, C curve, 16A Bipolar circuit breaker, C curve, 25A Bipolar circuit breaker, C curve, 32A Circuit breakers, D curve Bipolar circuit breaker, D curve, 8A Bipolar circuit breaker, D curve, 16A Bipolar circuit breaker, D curve, 25A Bipolar circuit breaker, D curve, 32A Bipolar circuit breaker, D curve, 40A pole circuit breaker, D curve, 10A pole circuit breaker, D curve, 16A pole circuit breaker, D curve, 25A pole circuit breaker, D curve, 32A 2 Differential circuit breakers, type AC Bipolar differential circuit breaker, type AC, 16A Bipolar differential circuit breaker, type AC, 25A Bipolar differential circuit breaker, type AC, 40A pole differential circuit breaker, type AC, 16A pole differential circuit breaker, type AC, 25A pole differential circuit breaker, type AC, 40A ACCESSPRO 111

10 BWT CONSTRUCTION & RENOVATION Complies with the following standards: Ladders and hand rails NF EN (October 2015): Family pools - Part 1: General requirements and test methods. NF EN (October 2015): Family pools - Part 2: Safety requirements and test methods specific to in-ground pools. NF EN (October 2015): Family pools - Part 3: Safety requirements and test methods specific to above-ground pools. NF EN (February 2016): Equipment for commercial pools - Part 2: safety requirements and test methods applicable to ladders and hand rails. Booster pumps: EN May 2013 : Household and similar electrical appliances General requirements. Directive 2011/65/EU: the RoHS 2 / Reduction of Hazardous Substances in electric and electronic devices. EN A2 February 2012: Electromagnetic Compatibility Part 1: Emission. EN A2 January 2009: Electromagnetic Compatibility Part 2: Immunity. Directive 2014/30/EU: the Electromagnetic Compatibility directive. Directive 2006/42/EC: the Machine directive. Directive 2014/35/EC: the Low Voltage directive. Counter-swim units DTP No. 12: Counter-swim units. EN (Nov. 2011): Equipment for commercial pools. Part 1: General safety requirements and test methods. 112

Domae. The right solution for distribution boards

Domae. The right solution for distribution boards Domae The right solution for distribution boards Guaranteed quality and adapted solutions Domae : SIRIM approved The quality marks prove product conformity to their reference standard. They guarantee:

More information

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module transformers and buzzers and bells socket outlets and special supports 042 25 042 52 041 07 042 80 042 85 Pack Cat.Nos Bell transformers dconform to IEC / EN 61558-2-8 Protected against overloads and short

More information

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat

More information

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos: PHASE CONVERTERS MODEL NO: PC40 and PC60 MODEL PART No: NO: 6012805 PC20 and PC40 6012810 PC60 PART Nos: 6012800 6012805 6012810 OPERATING & MAINTENANCE INSTRUCTIONS 0107 Specifications PC20 PC40 PC60

More information

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter.

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter. Standard AC SB5W Standard AC Intro duction Induction Reversible Right -Angle Gearheads SB5W AC Speed Control Inverter SB5W US ES2 FE1/FE2 Watertight, Dust-Resistant Torque Accessories Installation A-143

More information

MASTERYS IP+ 10 to 80 kva

MASTERYS IP+ 10 to 80 kva MASTERYS IP+ 10 to 80 kva OBJECTIVES The aim of these specifications is to provide: the information required to choose the right uninterruptible power supply for a specific application. the information

More information

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S Product Manual ABB i-bus EIB EIB Power Supply Units SV/S 30.320.5 SV/S 30.640.5 SU/S 30.640. Intelligent Installation Systems Contents Page EIB Power Supply Units. Introduction.........................................

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

Power Supply. & Door Controllers 238 SECURITY DOOR CONTROLS

Power Supply. & Door Controllers 238 SECURITY DOOR CONTROLS Security Door Controls & Door Controllers 5 SDC Access Control Power Supplies have been developed specifically to support access controls and electric locking hardware with clean, consistent power. Combined

More information

Btdin RCBO 6000A up to 63A (2P)

Btdin RCBO 6000A up to 63A (2P) Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics.... 4-29 6. Compliance - Approvals... 30 7. Curves... 30-34 8.Auxiliaries-

More information

New DX 3 High rating & breaking capacity

New DX 3 High rating & breaking capacity New High rating & breaking capacity a new range OF MOduLar CirCuiT BrEakErs up TO 125 a T new dx³ MCBs AN ENHANCED range for HIgH-pErforMANCE INstALLAtIoNs DX³ : the new Legrand MCBs with dx³, Legrand

More information

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Dycon D2430 EN54-4 Fire Alarm Power Supply Series Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product

More information

DEVICE STATE/BYPASSED FAILURE OVERLOAD

DEVICE STATE/BYPASSED FAILURE OVERLOAD Technical specifications Type 5. 7. Control electronics Rated values Terminal Rated control supply voltage A1A2 V AC 115 230 115 230 Tolerance % -15+10-15+10 Rated control supply STANDBY ma 15 15 Rated

More information

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw DELPHYS GP Green Power 2.0 range 160 to 1000 kva/kw OBJECTIVES The aim of these specifications is to provide: the information required to choose the right uninterruptible power supply for a specific application.

More information

Control Box CB12. Data sheet LINAK.COM/MEDLINE-CARELINE

Control Box CB12. Data sheet LINAK.COM/MEDLINE-CARELINE Control Box CB12 Data sheet LINAK.COM/MEDLINE-CARELINE CB12 The CB12 product range features two standard versions, which are ideal for a vast number of medical and industrial applications. In general the

More information

DC POWER SUPPLY SYSTEMS

DC POWER SUPPLY SYSTEMS DC POWER SUPPLY SYSTEMS double branch Rectifier - SCR type TITANIUM 2R-SCR PLUS SERIES TITANIUM 2R-SCR rectifier series belongs to the Double Branch category thus provided with two independent AC / DC

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

ARCHITECTURAL DOOR HARDWARE POWER SUPPLIES & TRANSFORMER CATALOG

ARCHITECTURAL DOOR HARDWARE POWER SUPPLIES & TRANSFORMER CATALOG ARCHITECTURAL DOOR HARDWARE POWER SUPPLIES & TRANSFORMER CATALOG January 1, 2017 v3 West Coast Office (800) 544-4422 East Coast Office (800) 225-6737 intldoorclosers.com Index POWER SUPPLIES & TRANSFORMERS

More information

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are: Introduction Motor starters are one of the major inventions for motor control applications. As the name suggests, a starter is an electrical device which controls the electrical power for starting a motor.

More information

Description. Positive safety relays

Description. Positive safety relays Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic

More information

TECHNICAL MANUAL. Inverter / Charger Combi. Combi SW 12V 1600VA Réf : PF Combi SW 24V 3800VA Réf : PF NOT_COMBI_SW-00

TECHNICAL MANUAL. Inverter / Charger Combi. Combi SW 12V 1600VA Réf : PF Combi SW 24V 3800VA Réf : PF NOT_COMBI_SW-00 TECHNICAL MANUAL EN Inverter / Charger Combi Combi SW 12V 1600VA Réf : PF.16088 Combi SW 24V 3800VA Réf : PF.16089 SAFETY PRECAUTIONS TO PREVENT ANY RISK OF ELECTRIC SHOCK OR FIRE, READ THIS MANUAL CAREFULLY

More information

Controller Specification Sheet

Controller Specification Sheet Controller Specification Sheet MC9320AXXXBX Proportional Inhibitor Dosing, Conductivity Bleed Control, Redox Control of Oxidising Biocide and Secondary Biocide Dosing PULSAtrol Controllers are microprocessor

More information

Simply reliable. ABB Single-phase Transformers. When transformation means safety and control.

Simply reliable. ABB Single-phase Transformers. When transformation means safety and control. Simply reliable. ABB Single-phase s. When transformation means safety and control. 2CSC446005B0201 Robust and reliable. The two ranges of ABB transformers - to meet every need. The operational control

More information

Sentry Technical. Miniature Circuit Breakers (MCBs) Standards and approvals. Description. Technical specification

Sentry Technical. Miniature Circuit Breakers (MCBs) Standards and approvals. Description. Technical specification 543 technical hotline +44 ()1268 56372 Standards and approvals Sentry MCBs are designed to fully comply with the relevant requirements of BS EN 6898: 23. They all feature positive contact status indication

More information

SECTION B1: MACHINE COMPONENTS

SECTION B1: MACHINE COMPONENTS SECTION B1: MACHINE COMPONENTS The machine portion of the Injected Metal Assembly system provides the means for: holding, heating and injecting the alloy; distributing and controlling electrical, pneumatic,

More information

Battery Power Inverters

Battery Power Inverters Battery Power Inverters Renogy 500W 1000W 2000W Pure Sine Wave Inverter Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 1 Version 1.4 Important Safety Instructions Please save these instructions.

More information

NO-BREAK KS. Dynamic UPS system PRESENTATION

NO-BREAK KS. Dynamic UPS system PRESENTATION NO-BREAK KS Dynamic UPS system PRESENTATION Contents Chapter 1: Description of No-Break KS System...3 Chapter 2: Operation when mains power is available...4 Chapter 3: Operation when mains supply is disrupted...6

More information

MoDPlus Din Distribution Boards

MoDPlus Din Distribution Boards MoDPlus Din Distribution Boards Introduction MoDPlus DIN Distribution Panel Board System MoDPlus Din type Distribution Board System has been designed and developed locally, incorporating features and benefits

More information

REVO SSR, S1PH & A1PH up to 40A The solid-state relay evolution

REVO SSR, S1PH & A1PH up to 40A The solid-state relay evolution REVO SSR, S1PH & A1PH up to 40A The solid-state relay evolution General description REVO is a compact family of solid state switches designed to replace contactors. Single phase thyristor units up to 40A.

More information

RVS-AX Instruction Manual

RVS-AX Instruction Manual RVS-AX Analog Soft Starter 8-170A, 220-600V Instruction Manual Ver. 10/11/2009 2 Table of Content RVS-AX Instruction Manual 1. TABLE OF CONTENT 1. Table of Content...2 2. Safety & Warnings...3 2.1 Safety...3

More information

Effective discrimination of protective devices

Effective discrimination of protective devices Effective discrimination of protective devices In the event of a fault occurring on an electrical installation only the protective device nearest to the fault should operate,leaving other healthy circuits

More information

NEW TX³ RANGE PROTECTION YOU CAN RELY ON

NEW TX³ RANGE PROTECTION YOU CAN RELY ON TX³ NEW RANGE TRUSTED PROTECTION FOR YOUR INSTALLATIONS GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES NEW TX³ RANGE PROTECTION YOU CAN RELY ON Designed to meet the requirements of

More information

DKG-114 MANUAL AND REMOTE START UNIT

DKG-114 MANUAL AND REMOTE START UNIT DKG-114 MANUAL AND REMOTE START UNIT FEATURES Both manual and remote controlled engine starting and stopping, Automatic shutdown on fault condition, Optional cooldown cycle on remote start operation, Optional

More information

dx 3 protection that meets your requirements GloBal SpecialiSt IN electrical AND DIgITAl BUIlDINg INFrASTrUCTUreS catalogue pages inside

dx 3 protection that meets your requirements GloBal SpecialiSt IN electrical AND DIgITAl BUIlDINg INFrASTrUCTUreS catalogue pages inside dx 3 protection that meets your requirements catalogue pages inside GloBal SpecialiSt IN electrical AND DIgITAl BUIlDINg INFrASTrUCTUreS the new dx 3 legrand offer offers you leading-edge technical features

More information

Application Engineering

Application Engineering Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor

More information

Glossary/Technical appendix

Glossary/Technical appendix Contents Power Supplies Overview.2 Standards and approvals.4 Glossary.6 1460790000 2014/2015.1 Power Supplies Overview Power Supplies Overview Power supplies are important links in the energy supply chain

More information

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

Green Power 2.0 MASTERYS GP

Green Power 2.0 MASTERYS GP Green Power 2.0 MASTERYS GP 60 to 120 kva/kw OBJECTIVES The aim of these specifications is to provide: the information required to choose the right uninterruptible power supply for a specific application.

More information

PRODUCTS: POWER SUPPLY

PRODUCTS: POWER SUPPLY PRODUCTS: POWER SUPPLY Impact Lighting Inc. All rights reserved. Impact Lighting Inc. Reserves the right to change specifications without notice. 138 POWER SUPPLY 15W AC-DC [12V/1.25A] UNIVERSAL POWER

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

Power supply for fire detection and fire alarm systems, smoke and heat control systems, and other fire protection systems, series ZSP135-DR

Power supply for fire detection and fire alarm systems, smoke and heat control systems, and other fire protection systems, series ZSP135-DR Power supply for fire detection and fire alarm systems, smoke and heat control systems, and other fire protection systems, series ZSP135-DR The power supply is a guaranteed source of 24V voltage. The wall

More information

HWP Protection Board

HWP Protection Board February 2009 HWP Protection Board Features and Operation This board provides the system protection features necessary to keep our HWP (Water Sourced Heat Pump) units safe in the instances when they are

More information

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7 EBL 208, Art.-No 911.430 Seite 1 / 7 Contents 1. Description 2. Safety Information 3. Operating Instructions 4. Transport, Storage, Installation 5. Electrical Installation 6. Power-Up, Shut-Down, Maintenance

More information

FUSES. Safety through quality

FUSES. Safety through quality Safety through quality HH HIGH VOLTAGE Over many decades SIBA has developed a global product line of High Voltage Fuses that are comprehensive for any and all applications. Superior engineering, advanced

More information

SITESTAR ELECTRONICS CABINET DESCRIPTION

SITESTAR ELECTRONICS CABINET DESCRIPTION SITESTAR ELECTRONICS CABINET DESCRIPTION SiteTel Sweden AB Haukadalsgatan 8A, SE-164 40 Kista, Sweden www.northstarbattery.com Contents 1 INTRODUCTION... 4 1.1 TARGET GROUP... 4 1.2 DOCUMENTS... 4 1.3

More information

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.:

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.: Extract from the online catalog MINI-DC-UPS/24DC/2 Order No.: 2866640 Uninterruptible power supply with integrated power supply unit, 2 A, in combination with MINI-BAT/24/DC 0.8 AH or 1.3 AH Commercial

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL)

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL) LINEAR LED DRIVERS ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL) 186443, 186444, 186486, 186487, 186488, 186491, 186492, 186737 Typical Applications Built-in in linear luminaires for Office lighting

More information

B BASIC HEAT TREATMENT CONSOLE

B BASIC HEAT TREATMENT CONSOLE Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL

More information

FAMILY. 1-Phase 1 Up to 25A Up to 40A Up to 80A Up to 600VAC 3-Phase, 2 leg 1 No Up to 33A Up to 80A Gang 2 units

FAMILY. 1-Phase 1 Up to 25A Up to 40A Up to 80A Up to   600VAC 3-Phase, 2 leg 1 No Up to 33A Up to 80A Gang 2 units THE DIN-A-MITE FAMILY 1 Refer to curves on reverse side for specific ratings. ➁ angle fire is not CE approved for conducted or radiated emissions. ➂ Will fit within the width dimension of most comparable

More information

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required! DB 750-205 January 2007 Supercedes: December 2006 Now available with Vacuum Interrupter Monitor VBT Switch 15kV - 69kV VBU-T Switch 69kV - 230kV Longest Life Product for Electric Furnace Applications!

More information

DX³ 4-pole RCBO 6000 A/10 ka

DX³ 4-pole RCBO 6000 A/10 ka 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery AC/DC Battery Controller Power Supply TSPC-240UPS Series Compact universal 24 VDC power supply with integrated battery controller module Battery protection for over voltage, deep discharge, short circuit

More information

Central Battery Systems Loadstar AC/DC Systems

Central Battery Systems Loadstar AC/DC Systems The Loadstar range of AC/DC central battery units comply with the latest relevant European and British standards. High quality, cost effective units provide secure sources of emergency power for escape

More information

Revision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide

Revision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide Revision 8 THERMO TECHNOLOGIES USDT 2001 Differential Controller Installation and User s Guide USDT 2001 DIFFERENTIAL CONTROLLER Installation and User s Guide Table of Contents Introduction General Information

More information

Evolution 650/650 Rack 1U 850/850 Rack 1U 1150/1150 Rack 1U 1550/1550 Rack 1U Installation and user manual FR/AA - Page 1

Evolution 650/650 Rack 1U 850/850 Rack 1U 1150/1150 Rack 1U 1550/1550 Rack 1U Installation and user manual FR/AA - Page 1 www.mgeups.com _ Evolution 650/650 Rack U 850/850 Rack U 50/50 Rack U 550/550 Rack U Installation and user manual P O W E R P R O V I D E R R U P T I B L E T E R N I N E U T H 3400364FR/AA - Page 3400835EN/AA

More information

SUBMERSIBLE WATER PUMP

SUBMERSIBLE WATER PUMP SUBMERSIBLE WATER PUMP MODEL NO: CSV1A, CSV2A PART NO: 7230582, 7230602 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS 05/14 iss 4 INTRODUCTION Thank you for purchasing this CLARKE Submersible

More information

Phoenix Inverter

Phoenix Inverter Manual EN Handleiding NL Manuel FR Anleitung DE Manual ES Appendix Phoenix Inverter 12 250 12 375 12 500 12 800 24 250 24 375 24 500 24 800 48 250 48 375 48 500 48 800 1. Safety instructions WARNING: ELECTRIC

More information

SYSDrive Frequency Inverter

SYSDrive Frequency Inverter SYSDrive Frequency Inverter T V/f control T PID control T Standard LED, optional LCD operator T Fieldbus options: DeviceNet T 7 configurable digital inputs T 3 configurable digital outputs T Low audible

More information

Low Voltage A GE Power Controls Company. General catalogue

Low Voltage A GE Power Controls Company. General catalogue Low Voltage A GE Power Controls Company General catalogue this is a blanc page Miniature circuit breakers A Miniature circuit breakers AC miniature circuit breakers Benefits of the new MCB s A 3 The AEG

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE4120 AUTO MAINS FAILURE MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel:

More information

DC POWER SUPPLY ALIMENTATION C.C.

DC POWER SUPPLY ALIMENTATION C.C. DC POWER SUPPLY ALIMENTATION C.C. ISO-TECH IPS 303A 201-3424 ISO-TECH IPS 601A 201-3446 SAFETY TERMS AND SYMBOLS These terms may appear in this manual or on the product: WARNING. Warning statements identify

More information

AUTOMATIC 12 WAY HEAT TREATMENT CONSOLE

AUTOMATIC 12 WAY HEAT TREATMENT CONSOLE Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION Star/delta starter Description: The electromagnetic starters LT 3 Dxx series are devices designed for remote control, direct control and protection of induction motors coiled and

More information

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw MODULYS RM GP Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw 19 OBJECTIVES The aim of these specifications is to provide the information required to prepare the system and installation

More information

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw MODULYS RM GP Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw 9 OBJECTIVES The aim of these specifications is to provide the information required to prepare the system and installation

More information

ATS* By-Pass solution

ATS* By-Pass solution ATS* solution Other enclosed switches tablo_22_a_1_cat site_366_483_484_a Enclosed ATS from 4 to 32 A Function ing between 2 sources for reliability of the power supply. Single Line & ouble Line of the

More information

Electronic Pressure Switches

Electronic Pressure Switches 96 Pressure Switches Electronic Pressure Switches Electronic E.5 switching output Electronic pressure switches, High-Performance series with one switching output Outstanding overpressure protection (up

More information

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS A. 11 KV SWITCHGEAR 1.0 SWITCHGEAR ASSEMBLY 1.1 Make : 1.2 Type : 1.3 Reference Standard : 1.4 Voltage (Nom./Max.) KV : 1.5 Phase, Frequency No,Hz.

More information

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2 DESCRIPTION AND FEATURES... 3 CHARGING STAGES... 4 Art. No. EC-315 Art. No. EC-330 Art. No. EC-340 PROTECTIONS... 5 INSTALLATION...

More information

Power thyristor units. 460 series. Control of single-phase resistive and inductive loads. User Manual

Power thyristor units. 460 series. Control of single-phase resistive and inductive loads. User Manual Power thyristor units 460 series Control of single-phase resistive and inductive loads User Manual Copyright Eurotherm Automation 1996 All rights reserved. All reproduction or transmission in any form

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 47681 Vari-Green Motor and Controls Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Dycon D1532SM EN50131/PD6662 Grade 3, 12V 2A Power Supply Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Tel: +44 (0)1443 471 900 Unit A Cwm Cynon Business Park Mountain

More information

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient

More information

Power Electronics. Motor brake relay GA 9031 ministop

Power Electronics. Motor brake relay GA 9031 ministop Power Electronics Motor brake relay GA 90 ministop 0 Thyristor electronic brake relay for motors up to kw Adjustable braking current up to 0 A Adjustable braking time Automatic standstill monitoring (optional)

More information

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com

More information

Vigilec doble. Pump controlller and protection for two (3ph/1ph) pumps INSTALLATION AND OPERATION

Vigilec doble. Pump controlller and protection for two (3ph/1ph) pumps INSTALLATION AND OPERATION V2P/V2T Vigilec doble INSTALLATION AND OPERATION V2P V2T Pump controlller and protection for two (3ph/1ph) pumps (V2P: control by pressure switches/ V2T: control by pressure transducer) General Description

More information

SDM72 Start on Demand Modules

SDM72 Start on Demand Modules Capricorn Controls DA04SDM72-2 Revised Design Page 1 of 6 SDM72 Start on Demand Modules Genset Controls - Timers - Monitors - Trips - Battery Charging - Spares & Accessories - Custom Products Application

More information

Boiler Management Unit (BMU)

Boiler Management Unit (BMU) 7 495 Boiler Management Unit (BMU) LMU74... LMU75... LMU7 are digital Boiler Management Units (BMUs) for use in gas-fired appliances equipped with premixing burners. LMU74 without combustion optimization

More information

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers

More information

Frost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor

Frost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor Frozen pipes can be a costly problem. When pipes are exposed to subzero temperatures they can burst, leading to considerable damage and disruption. The Raychem frost protection system provides an efficient

More information

Consumer unit solutions to meet the requirements of the new 17th edition amendment 3 regulations

Consumer unit solutions to meet the requirements of the new 17th edition amendment 3 regulations MEMT Memera full metal consumer units and protective devices Consumer unit solutions to meet the requirements of the new 17th edition amendment 3 regulations Memera full metal consumer units and protective

More information

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated

More information

Application Engineering

Application Engineering Application Engineering March 2011 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital compressor or the

More information

Industrial Control Transformers

Industrial Control Transformers 6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids

More information

Multi-Mover Charger for model L25

Multi-Mover Charger for model L25 Multi-Mover Charger for model L25 Important safety instruction. Keep these instructions. This manual contains important instructions for the safety of the user and the operation of the device. 1. SYMBOLS

More information

Motor. Document # Vari-Green Motor and Controls. Table of Contents. Features, Operation, Wiring and Troubleshooting

Motor. Document # Vari-Green Motor and Controls. Table of Contents. Features, Operation, Wiring and Troubleshooting Document #473681 Vari-Green Motor and Controls Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble,

More information

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2 1 of 5 Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2 1. Continuing to answer the following questions indicates that you understands that the presented material

More information

TRADE PRODUCTS. Electronic systems for recreational vehicles Supplying controlling indicating

TRADE PRODUCTS. Electronic systems for recreational vehicles Supplying controlling indicating TRADE PRODUCTS Electronic systems for recreational vehicles Supplying controlling indicating All systems under control Monitoring and controlling systems by Schaudt leading in safety and comfort in recreational

More information

MAGNETIC MOTOR STARTERS

MAGNETIC MOTOR STARTERS Chapter 6 MAGNETIC MOTOR STARTERS 1 The basic use for the magnetic contactor is for switching power in resistance heating elements, lighting, magnetic brakes, or heavy industrial solenoids. Contactors

More information

Solar inverter AX-series

Solar inverter AX-series Power Supplies Inverters Solar inverter AX-series 1-5kVA Multifunctional inverter NEU / NEW PV inverter PV / Battery Charger with 3-stage charge Battery-backed power supply Sine wave inverter with charging

More information

SECURITY DOOR CONTROLS

SECURITY DOOR CONTROLS CR4 FOUR STATION CONTROL MODULE The CR4 module operates on 12V or 24V DC and provides control of four (4) stations. Each CR4 station accepts a Dry () trigger input and provides one (1) Fused 2 Amp SPDT

More information

LR9 F OVERLOAD RELAYS

LR9 F OVERLOAD RELAYS Issued November 2009 DATA SHEET LR9 F OVERLOAD RELAYS Based on Schneider MKTED2050EN Catalogue General 6 Motor protection Operating conditions There are many possible causes of electric motor failure.

More information

WARNING MANUFACTURER ASSUMES NO LIABILITY IF UNIT OPERATED IN AN UNSAFE MANNER.

WARNING MANUFACTURER ASSUMES NO LIABILITY IF UNIT OPERATED IN AN UNSAFE MANNER. WARNING MANUFACTURER ASSUMES NO LIABILITY IF UNIT OPERATED IN AN UNSAFE MANNER. WARNING THIS INSTRUMENT GENERATES AND DELIVERS A HAZARDOUSLY HIGH VOLTAGE (5kV). BE EXTREMELY CAREFUL WHEN USING THIS INSTRUMENT.

More information

Safety technique. Emergency Stop Module BH 5928, BI 5928

Safety technique. Emergency Stop Module BH 5928, BI 5928 Safety technique Emergency Stop Module BH 5928, BI 5928 with time delay safemaster 0226419 Function diagram According to EU directive for machines 98/37/EG According to IEC/E 60 204, E 954-1 Safety category

More information

ICG Switchgear Price List 2009

ICG Switchgear Price List 2009 ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section

More information

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology HGM1780 Automatic Genset Controller USER MANUAL Smartgen Technology Smartgen Technology Co., Ltd No. 28 Jinsuo Road Zhengzhou Henan Province P. R. China Tel: 0086-371-67988888/67981888 0086-371-67991553/67992951

More information

IRRIGATION 810-3T-PLUS TRANSMITTER GUIDE

IRRIGATION 810-3T-PLUS TRANSMITTER GUIDE IRRIGATION 810-3T-PLUS TRANSMITTER GUIDE Pg. 2 HOT SHOT OVERVIEW 3 STANDARD OPERATION MODE 4 HOW TO CONTROL AND SHARE MULTIPLE S 5 TRANSMITTER FUNCTION SWITCH SETTINGS 6 OPERATING THE TEST BEACON 7 OPERATING

More information

ELECTRICAL PANELS. Chap.

ELECTRICAL PANELS. Chap. ELECTRICAL PANELS 360 Panel System Electrical Panels 360 Panel System Modular Panels DC Electric Panels AC Electric Panels AC/DC Electric Panels Aber Marine Panels IP 67 Watertight Panels Rotary Switch

More information