INSTALLATION OPERATION AND MAINTENANCE MANUAL SMITSVONK HIGH ENERGY IGNITION UNIT TYPE: E-LIGHT

Size: px
Start display at page:

Download "INSTALLATION OPERATION AND MAINTENANCE MANUAL SMITSVONK HIGH ENERGY IGNITION UNIT TYPE: E-LIGHT"

Transcription

1 INSTALLATION OPERATION AND MAINTENANCE MANUAL SMITSVONK HIGH ENERGY IGNITION UNIT TYPE: E-LIGHT Read before commencement of all work! This ignition unit must be mounted in accordance with the applicable regulations. Smitsvonk Holland B.V. P.O. Box sales@smitsvonk.nl 2700 AD Zoetermeer Phone: +31(0) The Netherlands Fax: +31(0)

2 Table of contents Page Introduction....3 Safety...3 Storage and transportation....4 General technical data...5 Model number...6 Product description...7 Installation...8 Operation instruction Maintenance instruction Trouble shooting Dismantling and disposal EC declaration of conformity Durag Group company addresses WARNING: Please read this manual and adhere to it when making use of the device! Installation and maintenance procedures may only be carried out by authorized personnel! All local regulations and the prevailing codes of practice must be observed during installation! Improper installation, alignment and maintenance, as well as modifications by the customer, can all lead to personal injury or properly damage, as well as loss of warranty! DANGER! High voltage. Risk of fatal injury due to electrical power! There is a risk of immediate fatal injury if live components are touched. Damage to the insulation or to individual components can lead to fatal injury. A voltage of Volts is generated to create the ignition sparks in the ignition device. Post address: Visit and delivery address: Smitsvonk Holland B.V. Smitsvonk Holland B.V. P.O. Box 180 Goudstraat AD Zoetermeer 2718 RC Zoetermeer The Netherlands The Netherlands sales@smitsvonk.nl Phone: +31(0) Fax: +31(0) Website: : Smitsvonk_IOM _manual_e-light _2016-aprilapril 2

3 INTRODUCTION. Smitsvonk Holland B.V. designs, manufactures and installs ignition systems which have their application all over the world. Years of experiences are the foundations of Smitsvonk Holland B.V knowledge about burner technology and ignition mechanism. And yet this knowledge is still increasing. In order to increase the quality of our services, the knowledge is used to improve the existing ignition systems as well as in developing new ignition systems. The long operational life and the reliability of the ignition devices are characteristic of Smitsvonk products. Designing the products to the customer s required specifications attained this and this is where Smitsvonk Holland has strongly her believes in. Smitsvonk guarantees a safe use of the ignition systems only when this is used in the customers required application that is mentioned in her specifications. To use these ignition systems in applications of which it was not designed for is not recommendable. It can lead to dangerous situations. Users should be informed correctly before they start to use the ignition system. Smitsvonk user manual gives detailed information about the use, mounting, maintenance and other information about ignitions system. But users should be aware that these instructions cannot be given in the finest details. Whenever there is a situation the manual is not giving an answer, Smitsvonk advices you to contact our service department. SAFETY This section provides an overview of all important safety aspects for optimum protection of personnel as well as safe, trouble free operation. Failure to observe the operating instructions and safety remarks contained in this manual can cause serious injury. Owner s responsibility As the ignition unit is used commercially, the owner of the ignition unit is obliged to adhere to occupational safety regulations as well as any other applicable directives, legislation and standards. Alongside the occupational safety remarks contained in these operating instructions, the safety, environmental and accident prevention regulations governing the field of application of the portable ignition unit must be adhered to, whereby the following regulations in particular apply: The owner must be aware of the valid occupational safety regulations and also determine any additional potential hazards arising as a result of the specific working conditions applicable at the location in which the portable ignition unit is used, by performing a risk assessment. This must be implemented in the form of operating instructions governing operation of the portable ignition unit. The owner must test; throughout the service life of the ignition unit, whether the operating instructions drawn up by him still correspond with the latest revision of the relevant rules and regulations, and must update these where applicable. The owner must clearly regulate and define fields of responsibility for installation, operation, maintenance and cleaning. The owner must ensure that all employees involved in working with the ignition unit have read and understood the operating instructions. Furthermore, the owner must provide personnel training at regular intervals and inform staff of potential hazards. As the owner is also responsible for ensuring that the ignition unit is always in good technical working order the following requirements additionally apply: The owner must ensure that maintenance work is performed regularly. The owner must regularly check that all safety devices are fully functional and complete. The owner must provide the necessary protective gear for personnel. Smitsvonk_IOM _manual_e-light _2016-aprilapril 3

4 STORAGE AND TRANSPORTATION. Important: Till the day of delivery Smitsvonk is responsible for the supplied materials. Damages caused after the delivery are not under the guarantees of Smitsvonk anymore. If the customer is taking care of the transport itself the responsibility of Smitsvonk stops at the moment of transfer of the products. To minimise the chance of damages to the supplied materials Smitsvonk advises to observe the following points: Storage: If no assembling takes place in a short term, keep the goods in the packaging as long as possible. Be sure that in the storage accommodation the chances for damages are minimised. Device is to be stored in a dry and dust-free place. Ambient temperature during storage shall be 0-60 C. No operation and storage below dew point. Moisture must not exceed 60 %. Device shall be protected from mechanical damages. Transportation: The packaging protects the materials against shocks or others forms of extreme strains. During transportation of the goods and after removing the packaging please obtain the next: Prevent the goods against shocks or other extreme forms of strains that can damage the goods. Smitsvonk_IOM _manual_e-light _2016-aprilapril 4

5 GENERAL TECHNICAL DATA Ignition unit Enclosure dimensions : See model number Material enclosure (Safe area) : Aluminium, painted blue Material enclosure (explosion proof) : Cast aluminium Power supply (Min. Max.) : VDC Power consumption ignition unit : 13 VA Protection : IP66 Ignition energy : 2 Joule per spark Ignition tension : 2000 V Ignition frequency : 3 sparks per second Maximum continuous use till 60 ⁰C : 3 minutes, 3 minutes pause from 60 ⁰C to 70 ⁰C : 3 minutes, 6 minutes pause Maximum ignition cable length 1,5 mm2 : 35 meter Maximum ignition cable length 4 mm2 : 100 meter Connection Ignition signal : M3 (Screw terminal) Connection Power supply : Max. 2,5 mm2 Cable gland connection : 2 x M20*1,5 Ambient and storage temperature range : -40 to 70 ⁰C. Operating Humidity max. : 95% non-condensing humidity Mechanical shock : 9G, EN : 2008 (Direction X+/-, Y+/-, Z+/-) Vibration : 2G, EN : 2008 (Direction X, Y, Z) Weight : 2,5 kg Smitsvonk_IOM _manual_e-light _2016-aprilapril 5

6 MODEL NUMBER IGNITION UNIT E-LIGHT TYPE: E-LIGHT E-LIGHT ignition unit in aluminium enclosure 2 Enclosure dimension: 160 x 160 x 90 mm 3 Cable glands 2 x M20x1,5: x Hummel EMC cable gland, range 7-12 mm x Hummel EMC cable gland, range 7-12 mm 1 x DNC/RCN for flexible protection conduit for ignition cable. 4 Z = Option, special Ø M20 M Smitsvonk_IOM _manual_e-light _2016-aprilapril 6

7 PRODUCT DESCRIPTION An ignition unit supplies the tension that is needed to make a reliable spark for an ignition (pilot) burner, a spark plug or an ignition lance. The unit is built into an aluminium die-cast box, protection grade IP66. The ignition unit is suitable for a supply voltage as mentioned on the type plate. The diagram fig. A shows that the DC power supply is converted to 2000 V, Enclosure 1 µf CAPACITOR Mounting plate C+ C- Sparkplug 2 KV IGNITION UNIT VDC B E E + - Fig. A Power cable not by Smitsvonk The capacitor will be discharged via the thyristor across the low-tension spark plug in a short time and with a high current. Due to this short time of discharge and high current a flame-shaped spark on the spark plug is obtained, which is unaffected by filthiness, humidity and other disturbances. The ignition unit generates about 180 sparks a minute, also indicated by a red LED on the P.C.B. An bleeder resistor is installed to ensure that the capacitor will be discharged when the unit is switched off. Remark: the time for the ignition unit to spark, should not exceed the maximum of 3 minutes. Before opening the housing, switch off the power supply and wait for about one minute. Lethal voltages are generated inside the box. Do not touch any metal part inside the ignition unit. Smitsvonk_IOM _manual_e-light _2016-aprilapril 7

8 INSTALLATION Please pay attention to the following. Ignition unit The ignition has to be mounted on a stable background with a minimum bolt size of 4 x M6. Take care for sufficient earthing of the ignition unit. When mounting the ignition unit outside, be sure that there is sufficient protection against the weather conditions. Don t place the unit to close to heat resources. The low voltage ignition unit shall be mounted in a vertical position with the cable glands down. When the cover of the unit is mounted properly, no special measures need to be taken to prevent the ingress of dust or humidity into the box. Ignition cable Smitsvonk strongly recommend to use a Smitsvonk high energy ignition cable, type SEKB (1,5 mm2), SEKB (4 mm2) or type SEKB (1,5 mm2 Halogen free) The central conductor of the ignition cable is to be connected to the terminal marked 'B'. EARTHING LEAD OUTER SHEATH BRAIDING CONDUCTOR The earthing lead (drain wire) under the braiding should be connected to the earth terminal. This earthing lead (drain wire) is un-isolated wire and should be isolated with shrink foil. The B-terminal is for the signal to the Sparkplug (Bougie). This signal can be 2 kv. Use suitable cable thimbles to connect the different wires. Smitsvonk_IOM _manual_e-light _2016-aprilapril 8

9 The power supply cable shall be connected to the terminals marked '+'(Line) and '-'(Neutral). The earth conductor shall be connected to the earth terminal. The electrical connection for the power supply is by screw terminals for stranded conductor wit h a cross-section between 0,75 and 2,5 mm2. CONNECTOR POWER SUPPLY CABLE Cable glands Unit is provided with 2 brass nickel plated cable glands for braided cable. Install the cable braiding according instruction of the cable gland supplier. COVER PLEXIGLAS PROTECTION PLATE IGNITION CABLE POWER SUPPLY CABLE Smitsvonk_IOM _manual_e-light _2016-aprilapril 9

10 WARNING!!! Cables must be connected carefully: The insulation must extend up to the terminal. Notice the maximum cable temperature. Do not operate the equipment above the maximum cable and equipment temperature. Take care not to damage the conductor. Do not clamp in any conductor insulation. Do not confuse conductors. All screws on the connection terminals must be tightened securely. Max. torque to the power supply terminal is from 0,5 to 0,6 Nm. All cores must be connected to the terminals. Do not forget to place the Plexiglas protection plate at the inside of the enclosure Do not forget to close the cover with the integrated gasket. Smitsvonk_IOM _manual_e-light _2016-aprilapril 10

11 Cable gland information. Smitsvonk_IOM _manual_e-light _2016-aprilapril 11

12 OPERATION When power supply is switch on to the ignition unit it will produce the energy for the sparks. Energy is conducted via the ignition cable to the sparkplug of the ignition (pilot) burner, sparkplug or ignition lance. MAINTENANCE Ignition unit The ignition unit hardly needs any maintenance during normal operation. Periodical maintenance, e.g. once a year, is confined to inspection of the interior of the unit. Inspect both the wiring as well as the components. Check whether all connections are still firmly fixed. When the sparkplugs are worn out the load of the capacitor will flow to earth by the bleeder resistor. When this will take too long (> 10 minutes) internal parts can be damaged! This device does not have an unlimited service life. It is designed for start-up cycles at nominal load. If 500 start-up cycles per day are assumed, its lifetime would therefore be approx. 10 years. This lifetime can be decrease considerably if the unit operates under harsh conditions (temperature, vibrations, dirt etc.) The end user shall therefore take care that regular safety-related checks are carried out at site. When the unit has reached the end of its lifetime it must be disposed of according to local regulations. Fuse, see fig. B Unit is provided with a replaceable 1,6 A (slow) type TR5 fuse. RED LED Fuse 1,6 A slow Recommended spare part: Fuse 1,6 A (slow) type TR5, Smitsvonk part number SEKM Fig. B Smitsvonk_IOM _manual_e-light _2016-aprilapril 12

13 TROUBLE SHOOTING When the system is malfunctioning the following checkpoints can be used in order to find the failure. The ignition unit is provided with a LED indicator (see fig. B) with the following blinking code: Possible causes can be: Failure Cause Result Action No power supply No LED blinking No power supply to the Check and or connect ignition unit power supply. Broken fuse No LED blinking No power supply to the ignition unit Replace fuse. Under voltage (< 10 Vdc at ignition unit) LED Continuous on Unit not in operation. Correct power supply. Over voltage > 30 Vdc at ignition unit. LED Slow blinking (1 Hz) Unit not in operation. Correct power supply and do a reset by power off for 10 seconds. Open loop, worn out sparkplug or broken cable LED blinking 3 Hz (normal) No spark Check cable connection or replace sparkplug. When the above mentioned points didn t solve the problems than Smitsvonk Holland B.V. advice you to contact us. DISMANTLING AND DISPOSAL Dismantling Switch off the system and secure against inadvertently being switched back on. Disconnect all electrical cables from the ignition unit E-LIGHT. Remove the ignition unit E-LIGHT and send for recycling. Disposal After the end of its service life, the flame monitor must be dismantled and sent for environmentally responsible recycling. By making your contribution to the correct disposal of this product, you are helping to protect the environment and preserve the health of your fellow human beings. Irresponsible disposal places the environment and our health at risk. Material recycling helps to reduce the consumption of raw materials. Current information on the recycling of this product can be obtained from your local authority and municipal waste management agency. Smitsvonk_IOM _manual_e-light _2016-aprilapril 13

14 Smitsvonk_IOM _manual_e-light _2016-aprilapril 14

15 DURAG GROUP COMPANY ADDRESSES Smitsvonk_IOM _manual_e-light _2016-aprilapril 15

Assembly and Maintenance Manual Type AS

Assembly and Maintenance Manual Type AS Assembly and Maintenance Manual Type AS Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_AS.docx

More information

Installation manual portable distributors

Installation manual portable distributors EN Installation manual portable distributors EN 60003206 Issue 11.2016 15/11/2016 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2 Intended

More information

Pan and Tilt Head CDD2416-T

Pan and Tilt Head CDD2416-T Pan and Tilt Head CDD2416-T Installation guide Before attempting to connect or operate this product, please read these instructions completely Williams Electronics Ltd www.w-e.co.uk Tel: +44 (0)2921 660

More information

Assembly and Maintenance Manual Type ASNU

Assembly and Maintenance Manual Type ASNU Assembly and Maintenance Manual Type ASNU Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_ASNU.docx

More information

Installation manual wall-mounted distributor

Installation manual wall-mounted distributor EN Installation manual wall-mounted distributor EN 60003233 Issue 11.2016 2016-14-11 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2

More information

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION 770 EC MACHINE DIRECTIVE COMPLIANCE DECLARATION (DIRECTIVE 89/392 EEC, APPENDIX II, PART B) Manufacturer: FAAC S.p.A. Address: Via Benini, 1 40069 - Zola Predosa BOLOGNA - ITALY Hereby declares that: the

More information

Assembly and Maintenance Manual Type RSBW

Assembly and Maintenance Manual Type RSBW Assembly and Maintenance Manual Type RSBW Hatschekstr. 36 69126 Heidelberg Germany Tel +49(0)6221 30470 Tel +49(0)6221 304731 info@stieber.de www.stieber.de Stieber Clutch Date of issue: 16/03/2017 GB

More information

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION EC MACHINE DIRECTIVE COMPLIANCE DECLARATION (DIRECTIVE 89/392 EEC, APPENDIX II, PART B) Manufacturer: FAAC S.p.A. Address: Via Benini, 1 40069 - Zola Predosa BOLOGNA - ITALY Hereby declares that: the 770

More information

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ,

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , ELECTRIC HOIST MODEL NO: CH2500B, CH4000B PART NO: 7630386, 7630391 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0517 - Iss 5 INTRODUCTION Thank you for selecting this Clarke Electric Hoist.

More information

Sinewave Inverters. SWING 150VA and 300VA. User s manual

Sinewave Inverters. SWING 150VA and 300VA. User s manual Sinewave Inverters SWING 150VA and 300VA User s manual 1 Warranty RIPEnergy is not manufacturer of these units. All technical information s, data s and dimension s rely on information s given by the manufacturer.

More information

c-go 24V/6A 24V/8A 24V/12A

c-go 24V/6A 24V/8A 24V/12A c-go 24V/6A 24V/8A 24V/12A Battery charger GB Instruction manual 1 Index 1. Product description... 2 2. Safety advices... 3 3. Quick start guide... 4 4. Operation... 4 5. Problem solving... 6 6. Specifications...

More information

Operating Instructions CYR52

Operating Instructions CYR52 BA01300C/07/EN/02.14 71261315 Products Solutions Services Operating Instructions CYR52 Ultrasonic cleaning Document information Warnings The structure, signal words and safety colors of the signs comply

More information

Dry installed pump type LANDY BTP.

Dry installed pump type LANDY BTP. OPERATION & MAINTENANCE MANUAL Dry installed pump type LANDY BTP. Landustrie Sneek BV Pieter Zeemanstraat 6 Tel. 0031 515-486888 P.O. BOX 199 Fax. 0031 515-412398 NL-8600 AD Sneek info@landustrie.nl The

More information

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference Please dispose of Packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

Actuators for air dampers and control valves of oil burners

Actuators for air dampers and control valves of oil burners 7 812 Actuators for air dampers and control valves of oil burners SQM1... SQM2... Reversible electromotoric actuators Torques: - SQM1... up to 10 Nm - SQM2... up to 20 Nm Running times: - SQM1... 14...100

More information

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY PRODUCT OVERVIEW The VADA series of self priming jet pumps combine the functional benefits of centrifugal pumps and the practical and qualitative benefits of self-priming pumps. The Venturi system the

More information

Installation and Operational Instructions for ROBATIC -clutch Type and Type Sizes 3 9

Installation and Operational Instructions for ROBATIC -clutch Type and Type Sizes 3 9 Please read the Operational Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunctions or to clutch failure, resulting in damage to other parts. Contents:

More information

Types K510 / K520 / K130 / K610 / K620 / K522 (Angle 90 ) Measuring ranges from -60 C to +200 C.

Types K510 / K520 / K130 / K610 / K620 / K522 (Angle 90 ) Measuring ranges from -60 C to +200 C. Operating manual (Translation) KombiTemp Types K510 / K520 / K130 / K610 / K620 / K522 (Angle 90 ) Measuring ranges from -60 C to +200 C. SIKA Ba_KoTp-W_en 02/2013. Please keep this operating manual for

More information

Installation and Operational Instructions for ROBATIC -clutch Types _.0 and _.0 Sizes 3 7

Installation and Operational Instructions for ROBATIC -clutch Types _.0 and _.0 Sizes 3 7 Please read these Installation and Operational Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunction or to clutch failure, resulting in damage to other

More information

UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.

UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10. BATTERY MODULE Long Life Battery: 10 to 12 Years According to EUROBAT Small Mounting Footprint Easy Access to the Terminals and the Fuse Heavy Duty Fuse Holder and Spare Fuse Included 3 Year Warranty,

More information

Operating Instructions

Operating Instructions Important Information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect

More information

TIDALFLUX 2300 F Quick Start

TIDALFLUX 2300 F Quick Start Quick Start Electromagnetic flow sensor for partially filled pipes The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS

More information

EStrong-series Emergency Stop

EStrong-series Emergency Stop Original instructions EStrong-series Emergency Stop ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand

More information

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet. Description Marking The ANTARES ExtSet makes it possible to distribute the Remote I/O ANTARES modules of an explosion-protected Remote I/O system ANTARES among a maximum of 4 metal mounting rails. For

More information

Installation and Operating Instructions Electric Vibrators HV/VFL Series

Installation and Operating Instructions Electric Vibrators HV/VFL Series Installation and Operating Instructions Electric Vibrators HV/VFL Series Original Instruction Würges Vibrationstechnik GmbH Daimlerstraße 9 D-86356 Neusäß Telephone +49 821 463081 Telefax +49 821 463084

More information

Module B Module C FOR THE WEATHER CONTROLLER MULTI-MIX INSTALLATION MANUAL REVISION: 1.0_EN

Module B Module C FOR THE WEATHER CONTROLLER MULTI-MIX INSTALLATION MANUAL REVISION: 1.0_EN Module B Module C FOR THE WEATHER CONTROLLER MULTI-MIX INSTALLATION MANUAL REVISION: 1.0_EN 05-2018 ELECTRIC DEVICE UNDER VOLTAGE! Before any action related to the power supply (cables connection, device

More information

Actuators for air dampers and control valves of oil burners

Actuators for air dampers and control valves of oil burners 7 812 Actuators for air dampers and control valves of oil burners SQM1... SQM2... Reversible electromotoric actuators Torques: - SQM1... up to 10 Nm - SQM2... up to 20 Nm Running times: - SQM1... 14...100

More information

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference. Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

AGV5-1, AGV5-2 FORM AGV5 OM 11-02

AGV5-1, AGV5-2 FORM AGV5 OM 11-02 ALTRONIC GAS FUEL VALVE OPERATING MANUAL AGV5-1, AGV5-2 FORM AGV5 OM 11-02 WARNING: DEVIATION FROM THESE INSTALLATION INSTRUCTIONS MAY LEAD TO IMPROPER ENGINE OPERATION WHICH COULD CAUSE PERSONAL INJURY

More information

Actuators for air and gas dampers

Actuators for air and gas dampers 7 814 Actuators for air and gas dampers SQM45... SQM48... Electromotoric actuators Torques: SQM45... up to 3 Nm SQM48... up to 20 Nm SQM48.6... up to 35 Nm Running times: 1) SQM45... 10... 120 s SQM48...

More information

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Compact System NRGS 11-2 NRGS Original Installation Instructions English Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive

More information

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX ATEX Type Certification marking for type L1X-EX, T1X-EX, T2X-EX Type of protection "d" explosion-proof enclosure Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

More information

Ex m Solenoid Operator Type 0519

Ex m Solenoid Operator Type 0519 nass magnet GmbH Eckenerstrasse 4-6 D-30179 Hannover Doc. No. 113-720-0002 Revision No. 2 01.06.2015 Ex m Solenoid Operator Type 0519 Operating Instructions Dear Customer! To ensure the function and for

More information

Sinewave Inverters. SWING pro 200VA and 350VA. User s manual

Sinewave Inverters. SWING pro 200VA and 350VA. User s manual Sinewave Inverters SWING pro 200VA and 350VA User s manual 1 Warranty RIPEnergy is not manufacturer of these units. All technical information s, data s and dimension s rely on information s given by the

More information

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009 HOT WASHER MODEL NO: KING 125 PART NO: 7320170 OPERATION & MAINTENANCE INSTRUCTIONS LS1009 INTRODUCTION Thank you for purchasing this Hot Washer. This machine is a portable, high pressure power washer,

More information

CFT24 &CFT230 PART NOS:

CFT24 &CFT230 PART NOS: FUEL TRANSFER PUMP Model Nos. CFT12, CFT24 &CFT230 PART NOS: 7160010, 7160020 & 7160030 INSTALLATION & OPERATING INSTRUCTIONS ORIGINAL INSTRUCTIONS GC05/18 REV 5 INTRODUCTION Thank you for purchasing this

More information

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230 230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230 PART NO: 7160050 OPERATION & MAINTENANCE INSTRUCTIONS GC0816 INTRODUCTION Thank you for purchasing this CLARKE Pump. The DFTP230 pump is a self-priming rotary

More information

Installation and Operational Instructions for ROBA-stop Holding Brake Type _._

Installation and Operational Instructions for ROBA-stop Holding Brake Type _._ Please read these Installation Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunctions or to brake failure, resulting in damage to other parts. Contents:

More information

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation Type 5411, 5413 3/2 or 4/2 way solenoid valve 3/2 oder 4/2-Wege-Magnetventil Électrovanne 3/2 ou 4/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 THE OPERATING INSTRUCTIONS The

More information

Electronic Ignition Module

Electronic Ignition Module 7 607 Electronic Ignition Module TQO31A27 Electronic ignition module for use with oil or gas burners operating with singleor double-pole ignition. The TQO31A27 and this Data Sheet are intended for use

More information

Electromotoric actuators

Electromotoric actuators s 4 520 ACVATIX TM Electromotoric actuators SQL321B.. SQL361B.. For VKF42.. butterfly valves SQL321B.. Operating voltage AC 220 V, 2-position (SPDT) control signal SQL361B.. Operating voltage AC 220 V,

More information

Assembly instructions

Assembly instructions Please carefully read the assembly instructions before beginning the installation, operation and maintenance of the solar facility. Noncompliance could cause injury to persons or damage to the equipment.

More information

Manual. EN Appendix. Lynx Ion BMS 400A / 1000A

Manual. EN Appendix. Lynx Ion BMS 400A / 1000A Manual EN Appendix Lynx Ion BMS 400A / 1000A 1. SAFETY INSTRUCTIONS 1.1 In general Please read the documentation supplied with this product first, so that you are familiar with the safety signs en directions

More information

UZK24.071, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS

UZK24.071, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE 24V, 7Ah Battery Capacity (2x 12V Batteries in Series) Small Mounting Footprint 2m Power Leads Included PT1000 Sensor for Battery Module Temperature Included Includes a Center-tap Terminal

More information

Aurora Wind Interface Box

Aurora Wind Interface Box Aurora Wind Interface Box Installation and Operator s Manual Page 2 of 15 REVISION TABLE Document Revision Author Date Change Description 1.0 T. Melzl 5/9/2006 First release of the document SAVE THESE

More information

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3 EN Operating manual Motorised zone valve Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3 This manual ensures safe and efficient use of the 3PV2 or 3PV8 force-actuated three-way valve with spring-loaded return

More information

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Type range: UN813.3ANI UN813.4ANI UN813.3ANDCB UN813.4ANDCB UN813.5ANI Fig. 1: UN813.3ANI Fig. 2: UN813.4ANI You have selected

More information

EASY CHARGE Waterproof portable Battery Charger

EASY CHARGE Waterproof portable Battery Charger EASY CHARGE Waterproof portable Battery Charger 1.1 AND 4.3 AMP MODELS EN NL, DE, FR, ES, IT USER S MANUAL WWW.MASTERVOLT.COM/EASYCHARGE-PORTABLE 10000009117/04 2 EN / EasyCharge 1.1 and 4.3 Amp - User

More information

Electronic Ignition Equipment

Electronic Ignition Equipment 7 608 Electronic Ignition Equipment TQG3 The TQG3 consists of a cable for connection to the safety shutoff valves of the VGU gas valves and electronic ignition equipment for use on gas boilers with single-

More information

Solenoid Operator 0513 / 1213

Solenoid Operator 0513 / 1213 nass magnet GmbH Run Nr. 5 Eckenerstraße 4-6 24.10.2006 D-30179 Hannover Rev. 5 061024 Solenoid Operator 0513 / 1213 Operating Instructions NN 8220 112 and EC Declaration of Conformity Dear Customer! In

More information

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800 Original instructions Operating Instructions for May 2010 Electric Internal Vibrators BA No. 1092E Series NCX and NCZ These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Type 5404 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating instructions...2 2 Intended use...3 3

More information

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality GE Digital Energy Power Quality User Manual Digital Energy Uninterruptible Power Supply ML Series UPS 350-500-700-1000 VA GE imagination at work GB User Manual Digital Energy Uninterruptible Power Supply

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS RTECK terminal boxes RTKB series IEC Ex EX010 TECHNICAL FILES CONTENTS: 1) Contents 2) General information 3) Safety information 4) Conformity to standards 5) Function 6) Technical

More information

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content 1. About this document Operating instructions.............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning

More information

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016 SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016 3009/16 en Ed.02.2016 Read these Operating Instructions before performing any transportation, installation, commissioning, maintenance or

More information

F3S-TGR-KHL1/-KHL3/-KHL3R

F3S-TGR-KHL1/-KHL3/-KHL3R Safety guard-lock door switches with full stainless steel body F3S-TGR-KHL1/-KHL3/-KHL3R The F3S-TGR-KHL3 safety-door switch keeps medium to large guard doors closed until hazards have been removed. It

More information

Actuators for air dampers and control valves of oil burners

Actuators for air dampers and control valves of oil burners 7 812 ISO 9001 Actuators for air dampers and control valves of oil burners SQM1... SQM2... Reversible electromotoric actuators Torques: - SQM1... up to 10 Nm - SQM2... up to 20 Nm Run times: - SQM1...

More information

ECON Limit Switch Box Fig

ECON Limit Switch Box Fig ECON Limit Switch Box Fig. 79651 Scan for manual Installation & Operation Manual for Limit Switch Box: Fig. 79651 Rev.4 1 Contents Page 1. INTRODUCTION 3 2. SWITCH BOX SPECIFICATION 3 3. SWITCH TYPE SELECTION

More information

Solenoid Operator 0516 / 1216

Solenoid Operator 0516 / 1216 nass magnet GmbH Edition no. 2 Eckenerstraße 4-6 2007-01-10 D-30179 Hannover Rev.2 070110 Solenoid Operator 0516 / 1216 Operating Instructions NN 8220 126 and EC Declaration of Conformity Dear Customer!

More information

BM kv Digital Insulation Tester USER MANUAL

BM kv Digital Insulation Tester USER MANUAL M BM5200 5 kv Digital Insulation Tester USER MANUAL CONTENTS Safety warnings...3 Symbols used on instrument...4 Cleaning...4 General description...5 Insulation resistance test modes...5 Automatic discharge...5

More information

GL1200T Cut & Seal. (GL1200 Seal only)

GL1200T Cut & Seal. (GL1200 Seal only) GL INSTRUMENTS & Operating Instructions Safe Seal Cut & Seal Welder for Filter Sacks GL1200T Cut & Seal (GL1200 Seal only) For industrial use only Important Safety & Operating Instructions Please read

More information

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work GE Digital Energy Power Quality User Manual Digital Energy Uninterruptible Power Supply ML Series UPS 350-500-700-1000 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)

More information

Instruction Manual. for Heating Cables and Cold Leads Type and Catalogue no and Hemstedt GmbH.

Instruction Manual. for Heating Cables and Cold Leads Type and Catalogue no and Hemstedt GmbH. Instruction Manual for Heating Cables and Cold Leads Type 68994- and 68997- Catalogue no. 68994- and 68997- Hemstedt GmbH Schleicherweg 19 D-74336 Brackenheim-Botenheim Phone +49 (7135) 9898-0 Fax +49

More information

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080 CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080 STI S.r.l has taken every care in collecting and verifying the documentation contained in this Instruction Manual. The information herein contained are

More information

Battery Charger. Series EASY Charger. User s manual

Battery Charger. Series EASY Charger. User s manual Battery Charger Series EASY Charger User s manual 1 Warranty RIPEnergy is not manufacturer of these units. All technical information s, data s and dimensions rely on information s given by the manufacturer.

More information

Operating Instructions

Operating Instructions Operating Instructions Terminal Box > 8150/1 > 8150/2 Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2 2.2 Operating Instructions Information...2 3 Intended Use...2 4 Safety

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions contain

More information

HST-BL-2830MS & HST-BL-2830MS-USA

HST-BL-2830MS & HST-BL-2830MS-USA HST-BL-2830MS & HST-BL-2830MS-USA Release date: 02/2017 High - System - Technik Im Martelacker 12 D-79588 Efringen-Kirchen Phone 0 76 28-91 11-0 Fax 0 76 28-91 11-90 E-Mail: info@hs-technik.com Web: www.hs-technik.com

More information

F3S-TGR-KM15/-KM16/-KH16

F3S-TGR-KM15/-KM16/-KH16 Safety door switches with partially or full stainless steel body F3S-TGR-KM1/-KM16/-KH16 This safety door switches use a stainless steel head or even a full stainless steel body to increase the robustness.

More information

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur Water flow rate transmitter Wasser-Durchfluss-Transmitter Transmetteur de débit d eau Operating Instructions Bedienungsanleitung Manuel utilisateur We reserve the right to make technical changes without

More information

DC Master 24/ A

DC Master 24/ A USERS MANUAL DC Master 24/12 50-60A DC-DC converter MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands Tel.: +31-20-3422100 Fax.: +31-20-6971006 www.mastervolt.com ENGLISH Copyright 2015

More information

Sinewave Inverters. Jazz 700VA and 1000VA. User s manual

Sinewave Inverters. Jazz 700VA and 1000VA. User s manual Sinewave Inverters Jazz 700VA and 1000VA User s manual 1 Warranty RIPEnergy is not manufacturer of these units. All technical information s, data s and dimension s rely on information s given by the manufacturer.

More information

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION VQ400M SERIES PRODUCT HANDBOOK APPLICATION The VQ400M Series class A safety combination valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers, melting

More information

ILED Aquarius Illuminated Windsock. User Manual

ILED Aquarius Illuminated Windsock. User Manual Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 3.1 The light fitting has a type plate:... 4 3.2 The junction box has a type plate:... 5 4. Product Description...

More information

Assembly and maintenance manual Type FSO, FSO-GR, FS, HPI

Assembly and maintenance manual Type FSO, FSO-GR, FS, HPI Type FSO, FSO-GR, FS, HPI Hatschekstr.36 69126 Heidelberg Deutschland Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 23.08.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\M1124E_0_FSO_FSO-GR_FS_HPI.docx

More information

Floodlight Range Installation Guide

Floodlight Range Installation Guide SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected

More information

UZK12.071, UZO GENERAL DESCRIPTION 2. DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 7AH 1/9.

UZK12.071, UZO GENERAL DESCRIPTION 2. DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 7AH 1/9. BATTERY MODULE Two Mounting Options: DIN-Rail or Panel/ Wall Mounting IP00 Open Type Protection Level Easy Access to the Terminals and the Fuse Heavy Duty Fuse Holder and Spare Fuse Included UZK12.071

More information

Electric Actuator Instructions

Electric Actuator Instructions BAC IOM Electric Actuator Instructions E024, E025, E026, E029 & E030 TABLE OF CONTENTS Electric Actuator Specifications...2 Overview...3 Actuator Wiring Diagrams...4 VMS-35 Specifications and Wiring Diagram...5

More information

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

EVZ Series (Small body) Explosion protected luminaire Operating Instructions EVZ Series (Small body) Explosion protected luminaire Operating Instructions Cooper Crouse-H i n d s Cooper E l ec t ron i c T ec h n ol og i es ( S h a n g h a i ) Co., L t d. No. 955 Shengli Road, East

More information

Zone 1 Linear Range - Installation Guide

Zone 1 Linear Range - Installation Guide Zone 1 Linear Range - Installation Guide CML14ATEX3119 & IEC Ex CML15.0001 This installation guide provides instructions for installing SPARTAN series of explosion protected Zone 1 Linear luminaires. Text

More information

Central Inverter SUNNY CENTRAL 500HE-20/630HE-20/720HE-20/ 760HE-20/800HE-20

Central Inverter SUNNY CENTRAL 500HE-20/630HE-20/720HE-20/ 760HE-20/800HE-20 Central Inverter SUNNY CENTRAL 500HE-20/630HE-20/720HE-20/ 760HE-20/800HE-20 Maintenance Manual SC500-800HE20-WH-en-10 98-4110410 Version 1.0 EN SMA Solar Technology AG Table of Contents Table of Contents

More information

S4562C 1085 COMBI BOARD APPLICATION. Contents PRODUCT HANDBOOK. General

S4562C 1085 COMBI BOARD APPLICATION. Contents PRODUCT HANDBOOK. General S4562C 1085 COMBI BOARD APPLICATION PRODUCT HANDBOOK The S4562C 1085 combi board is an integration of an on/off temperature control and an electronic ignition control. The S4562C 1085 combi board is intended

More information

ECS CONNECTION OF LARGE LV SERVICES TO SECONDARY DISTRIBUTION SUBSTATIONS

ECS CONNECTION OF LARGE LV SERVICES TO SECONDARY DISTRIBUTION SUBSTATIONS Network(s): Summary: ENGINEERING CONSTRUCTION STANDARD ECS 03-0054 CONNECTION OF LARGE LV SERVICES TO SECONDARY DISTRIBUTION SUBSTATIONS EPN, LPN, SPN This standard details the procedures to be undertaken

More information

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to RS-3 PRO RS-1007 PRO CAT IV Analog Clamp meter Series Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com RS-3 PRO RS-1007 PRO CAT IV Analog Clampmeter Series English

More information

Sinewave Inverter. HIPHOP pro 1500 HIPHOP pro User s manual

Sinewave Inverter. HIPHOP pro 1500 HIPHOP pro User s manual Sinewave Inverter HIPHOP pro 1500 HIPHOP pro 2000 User s manual 1 Warranty RIPEnergy is not manufacturer of these units. All technical information s, data s and dimension s rely on information s given

More information

Battery Charger Series EASY Charger

Battery Charger Series EASY Charger Battery Charger Series EASY Charger User s manual 1 Warranty RIPEnergy is not manufacturer of these units. All technical information s, data s and dimensions rely on information s given by the manufacturer.

More information

Battery Charger JCB- SCH20LI.2

Battery Charger JCB- SCH20LI.2 Safety and operating manual Battery Charger JCB- SCH20LI.2 ORIGINAL INSTRUCTIONS SAFETY INSTRUCTIONS WARNING: Read all safety warnings and all instructions.failure to follow the warnings and instructions

More information

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s.   PEGAS E Smart Manual EN 04 WELDING INVERTER PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL PEGAS 160-200 E Smart Manual EN 04 2/12 CONTENT: 1. INTRODUCTION... 3 2. SAFETY INSTRUCTIONS AND WARNINGS... 4 3. TECHNICAL DATA...

More information

Actionpac LNS4. Panel Installation Datasheet. Actionpac LNS4 RELEASE 1.0 JUNE In partnership

Actionpac LNS4. Panel Installation Datasheet. Actionpac LNS4 RELEASE 1.0 JUNE In partnership Actionpac LNS4 Panel Installation Datasheet ELECTROSTATIC SENSITIVE DEVICE This product forms part of a life safety system. Failure to correctly store, handle, install and maintain the product will directly

More information

Oil-free piston compressors KK and piston vacuum pumps KV

Oil-free piston compressors KK and piston vacuum pumps KV Oil-free piston compressors KK and piston vacuum pumps KV Installation and Operating Instructions 0678106030L02 1707V003 Contents Important information 1 About this document 2 1.1 Warnings and symbols

More information

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2 OPERATING AND MAINTENANCE MANUAL Product: Type: High Voltage AC Test Set KV3-250 mk2 KV4-300 mk2 KV5-100 mk2 KV5-100T mk2 KV5-200 mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge

More information

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE 2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE For Diaphragm Dosing Pumps FEM 1.02_.55 / FEM 1.09_.55 Controller board package, without pump: ID 160536 Operating and Installation Manual It is important to

More information

Safety instructions. Always... Never... Fire hazard! Dear customer,

Safety instructions. Always... Never... Fire hazard! Dear customer, Dear customer, Safety instructions Danger can occur when working with this punch driver due to improper handling and/or poor maintenance, which may damage the device and cause severe physical injuries.

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating Instructions... 2 2 Authorized use...

More information

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy NorthStar TM brand Instruction Manual SLIM Tach SL56 1.125 Thru-Shaft Diameter Magnetoresistive Encoder Designed for GE Wind Energy Patent Pending *791-1061-00* Rev. B Page 2 Table of Contents Chapter/Paragraph/Illustration

More information

For air dampers and control valves of oil or gas burners

For air dampers and control valves of oil or gas burners 7 813 Actuators For air dampers and control valves of oil or gas burners SQM33... Electromotoric actuators Torques: - SQM33.4 up to 1.2 Nm nominal output torque - SQM33.5 up to 3 Nm nominal output torque

More information

Operation & Maintenance Manual

Operation & Maintenance Manual Operation & Maintenance Manual Submersible pumps type LANDY DWP & Submersible pumps type LANDY DNP Explosion proof version Landustrie Sneek BV Tel. +31 515-486888 Pieter Zeemanstraat 6 Fax +31 515-412398

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION 11/05 Form #273 OPERATING INSTRUCTION MODEL 4105 Disital Earth Resistance Tester 2150 joshua's Path, Suite 302, Hauppauge, NY 11788 Phone : 1-800-645-5398 or 1-639-231-7050 Fax : 1-639-434-3128 E-mail

More information