1 Temperature Products Temperature Products u Electronic Products u Pressure Transducers u Mechanical Pressure Products u Valves & Regulators u Temperature Products u Level Products u Air Suspension Valves

2 Barksdale - the total control solutions partner At Barksdale, our goal is to help our customers Control Every Move. For us, this isn t simply a motto, but rather a vision that guides the way we do business with our valued customers. At every stage in the process from needs assessment, design and manufacturing to customer support, we provide peace of mind by delivering a total controls solution tailored to meet the specific needs of each customer. We accomplish this by leveraging the following: A Highly Experienced Team of engineers that work closely with customers to meet, exceed and even anticipate their every control need. A Diverse Product Portfolio of quality standard and custom-tailored product solutions that help control Pressure, Temperature, Level and Flow in the most demanding applications in the industry. Our Global Reach and Support via our: Worldwide direct sales force of experts Manufacturing facilities in North America and Europe Team of highly capable and friendly customer support staff that make it easy to do business with Barksdale anywhere in the world Dedicated Tools & Processes Production Part Approval Process (PPAP) to satisfy the most stringent quality control requirements Compliance with ISO 9001:2000 standards ATEX / IECx compliant facilities 6 Sigma culture / Process Capability 2

3 Table of Contents Temperature Switches Supplemental Guide 3 Temperature Switch Accessories 7 T9692X - Compact Explosion Proof Temperature Switch 9 Series MT1H, T2H - Remote Mount Temperature Switches 11 ML1H, L2H - Local Mount Temperature Switches 13 Series T1X, T2X, L1X - Explosion Proof Temperature Switches 15 Series TPR - General Purpose Switch 17 Series THR, THL - Temperature Switch 19 Series TXR, TXL - Explosion Proof Temperature Switch 21 Series ML1S - Bi-Metallic Switch 23 3

4 4

5 5

6 6

7 7

8 Temperature Temperature Switch Accessories Thermowells, Split Nut, Union Connector, Capillaries Standard Local Mount Standard Local Mount 1/2 NPT threads Sensor submersible in pressurized vessel; pressure range through 300 psi. Example: ML1H-H201S Sensor 3/4 NPT threads Thermowell Option: -W: Brass -WS: 316 Stainless Steel #10 Set screws (2); secures switch in thermowell; can be rotated 360 in well. Sensor submersible in pressurized vessel; pressure range: 1000 to 7000 psi, depending on material and temperature. NOTE: Barksdale standard models cannot be field converted to add a Barksdale thermowell. To order a standard temperature switch with thermowell, add -WS to the model number. Example: ML1H-H201S-WS Example: ML1H-H201S-WS To order replacement temperature switch for thermowell models, less thermowell, add -Z18 to model number. Example: ML1H-H201S-WS-Z18 Thermowells for High Pressure and Harsh Environments Thermowells for Remote Bulb and Capillary Models Only All electromechanical temperature switches may be used with a thermowell when pressures exceed 300 psi, if high velocities are present and with corrosive or abrasive medias. Thermowells also allow removal of the temperature switch or sensor without loss of contained media. When using a thermowell with a local mount temperature switch, two set screws are provided to secure the switch in the well allowing 360 rotation for easier electrical connection and readability. The use of a thermowell may increase response time to temperature change. By using heat transfer material, the increase can be kept to a minimum. Part Number Material P Process Connection NPT R V B Brass 1/ B Brass 3/ C 316SS 1/ C 316SS 3/

9 Temperature Switch Accessories Thermowells, Split Nut, Union Connector, Capillaries Split Nut Used to hold sensor bulb in standard thermowell. 1/2" NPT Part Number Union Connector Used to hold sensor bulb in extra length thermowell. Seals the process connection where no thermowell is used. Note: Union contains compression discs and will seal to 300 psi. Part Number Material P NPT B Brass 1/2 2-1/ B Brass 3/4 2-1/ C 316SS 1/2 2-1/ C 316SS 3/4 2-1/2 T9692X Models B Brass 1/2 2-1/ B Brass 3/4 2-1/ C 316SS 1/2 2-1/ C 316SS 3/4 2-1/2 A P(NPT) A Thermowell Pressure-Temperature and Velocity Limitations Maximum Fluid Velocity Feet Per Second Material Insertion Length-"U" 2-1/2" 4-1/2" 7-1/2" 10-1/2" 13-1/2 16-1/2" 19-1/2" 22-1/2" Brass (150) (83.5) Carbon Steel (270) (150) A.I.S & (350) (208) Monel (300) (167) The values in parentheses (00) represent safe values for water flow. Unbracketed values are for steam, air, gas and similar low density fluids. Pressure-Temperature Rating Lbs. Per Square Inch Material Temperature F Brass * * Carbon Steel A.I.S.I A.I.S.I Monel *Stainless Steel Recommended. Capillary Variations Examples Examples without Manual with Manual Description Suffix Reset Reset (-RD) Copper Units with A(added to any 302 SS Armor standard catalog) T1X-H150-A MT1H-G150-A-RD Stainless Steel Units With 302 SS Armor T2H-H601S-12-A T2H-H601S-12-A-RD Extra Length Capillaries Available as Special. (over 12 in length) ConsultFactory for part number, price and delivery Fruitland Avenue Los Angeles, CA % Fax: See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0028-D 01/ Printed in the U.S.A. 2 9

10 Compact Explosion Proof Temperature Switch T9692X Features IECEx & ATEX approved Compact design Convenient field adjustability NEMA 4X, 7 & 9 SPDT and DPDT switch Class I Div I Direct or remote mount Panel mount capability 316 stainless steel NACE compliant Armored capillary Applications Offshore platforms Safety panels Chemical plants & refineries Compressor skids Instrument panels Hazardous location applications General Specifications* Accuracy: Typical Life: Switch: Electrical Ratings: Materials: Bulb, Capillary & Armor: Enclosure: Local Mount Element: Electrical Connection: * See Product Configurator for additional options. 3% of full scale 1 million cycles SPDT, snap action, Class EE, simulated DPDT (optional) /250 VAC 5 30 VDC (EE class) 316 stainless steel 316 stainless steel Enclosure Ratings: NEMA 4X, 7 & series stainless steel 1/2 inch NPT male conduit connection 18 AWG, 18 (300 mm) free leads Approvals: ATEX/IECEx: UL: CSA: Ambient Operating Temperature: CSA & ATEX: CE 0081, LCIE 08 ATEX 6074X II 2 G, Ex d IIC T6 Gb IECEx LCIE X, -40 C Tamb 60 C Listed 366S, Class: I, Groups: A, B, C, D, -25 C Tamb 60 C Class: I, Groups: B, C, D -40 C Tamb 60 C -40 F to 140 F (-40 C to 60 C) UL: -13 F to 140 F (-25 C to 60 C) EMI/RFI: EN55011 Vibration: 10g s Hx, MIL-STD 202 F Shock: 50g s, 11 ms, MIL-S-901C Adjustment: Internal locking adjustment wheel, 1/16 hex set screw Weight: 3 lbs. maximum Wiring Code Wiring Diagram (SPDT) (DPDT) Lead Circuit #1 Circuit #2 Normally Closed Blue Orange Common Purple Brown Normally Open Red Yellow Ground Green NC (Blue) C (Purple) NO (Red) Ground (Green) INCR P NC1 (Blue) C1 (Purple) NO1 (Red) NC2 (Orange) C2 (Brown) INCR P NO2 (Yellow) Ground (Green) 10

11 PRESSURE P Compact Explosion Proof Temperature Switch Technical Drawing Dimensions in inches [mm] T9692X " FREE LEADS SEE WIRE COLOR CODE CHART FOR FURTHER DETAILS HEX WRENCH FLATS 1/2 NPT CONDUIT CONNECTOR #8-32 EXTENDED GROUND SCREW 1 23/32 [45.2] GRD SCREW 1" HEX TOOL REQUIRED 3.7 [97] MAX /2 NPT 2X.2 5 MOUNTING HOLES MAX 94 MAX CAPILLARY AND BULB NOT SHOWN FOR CLARITY.2 5 (ARMOR DIA.) (.06[1.6] NON-ARMOR).5 13 LOCAL MOUNT OPTION ARMOR VERSION SHOWN Product Configurator Example T9692X -1 EE Base Configurator T9692X Temperature switch Number of Circuits -1 SPDT switch -2 Simulated DPDT switch (2 SPDTs) Options Blank Standard -A 1 Stainless steel armor -SXXX -WXXX Factory preset Extra wire length (XXX=inches) Limit Switch Silver contacts EE V/250 VAC; 5 30 VDC Gold contacts GH 1 125/250 VAC Temperature Ranges Adjustable Range Approx. Deadband 2 Actuation Value Media Temperature Limits Proof Temperature F to 110 F (-23 C to 43 C) 5 F to 30 F (2.8 C to 16.7 C) -40 F to 160 F (-40 C to 71 C) 160 F (71 C) F to 220 F (35 C to 104 C) 5 F to 30 F (2.8 C to 16.7 C) 40 F to 270 F (4 C to 132 C) 270 F (132 C) F to 330 F (82 C to 165 C) 5 F to 30 F (2.8 C to 16.7 C) 70 F to 380 F (21 C to 193 C) 380 F (193 C) Capillary Length ft (1.8 meters) ft (2.7 meters) ft (3.7 meters) -001 Local mount 1 Not available in local mount 2 Deadband values indicated when used with the EE limit switch 3211 Fruitland Avenue Los Angeles, CA Fax: See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0029-B 02/ Printed in the U.S.A. 11

12 Remote Mount Temperature Switches Series MT1H, T2H Features Reliable & accurate Ambient temperature compensated NEMA 4, 13 UL, CSA & CE approved Single or dual switching Applications Marine & shipbuilding Railroad Oil & gas Medical Compressors Water equipment Process equipment Machine tools and industrial equipment General Specifications* Accuracy: (Repeatability) Switch: Electrical Characteristics: Wetted Parts: Electrical Connection: Electrical Ratings: Enclosure/Housing: * See Product Configurator for additional options. ±1% of mid-60% of full range. At constant ambient ±0.5% of full scale. (Knob indication is reference only) One (1) SPDT or two (2) independent SPDT circuits All models incorporate Underwriters Laboratories, Inc. and CSA listed single pole double throw snap-action switching elements. Switches may be wired normally open or normally closed. Copper or 304 stainless steel Single: 3-Pin terminal strip Dual: 6-Pin terminal strip AC value at 50% power factor , 250 volts AC, volts AC. Automatically reset by snap-action of switch. Watertight and dust-tight indoor and outdoor (NEMA 4)/oil-tight and dust-tight indoor (NEMA 13). Bulb & Capillary: Approvals: UL: CSA: Temperature Range: Adjustment: Weight: 6 and 12 foot length standard. See operating characteristics and product configurator. Underwriters Laboratories, Inc. and Canadian Standard Assoc. are listed under temperature indicating and regulating equipment. File No. E56247, Guide No. XAPX File No. LR34555, Guide 400-E-O Class 4813 See product configurator Tamper resistant external adjustment. Turn knob clockwise to increase setpoint. (Knob indication is reference only) Single: approximate 1.5 lbs. Dual: approximate 3.0 lbs. Wiring Code Wiring Diagram Lead Circuit #1 Circuit #2 Normally Closed Blue Orange Common Purple Brown Normally Open Red Yellow NO (Red) C (Purple) NC (Blue) T NO (Red) C (Purple) NC (Blue) NO (Yellow) C (Brown) NC (Orange) T MT1H T2H 12

13 Remote Mount Temperature Switches Series MT1H, T2H Technical Drawing T2H MT1H COPPER 3 16 Dimensions in inches (mm) Product Configurator H Blank M Blank Switch T1 T2 H Hermetically sealed limit switch option - Class I, Division II (requires AA, CC, GH or HH limit switch, 60 C Ta max.) Standard Single setpoint switch models Dual switch models Single SPDT Enclosure Dual switch 2 independent SPDT NEMA 4 enclosure NOTES: 1 Changing limit switch will effect dead band; See sales drawing. 2 Use G limit switch for single setpoint models that need this option. When selecting the manual reset option on dual setting switches (T2H), the manual reset limit switch will be on the high circuit. The low circuit limit switch must be specified by the customer. 3 Add S wetted material. FX models require stainless steel capillaries. Consult factory; minimum quantities required. 4 Add S wetted material adder and A armor adder to this. Capillary length 25 requires stainless steel capillary and armor. 5 Factory preset is available for all ranges, limited to 400 F setpoint(s). Example H M T1 H -HH 154 S -12 -A -FX Limit Switch 1 -H /250 VAC; VAC (standard) -B /250/480 VAC; VAC; VDC; VDC -G /250/480 VAC; VAC; VDC; MANUAL RESET -J /250 VAC; VAC (with elastomer boot) -L /250/480 VAC; VDC; VDC -M /250 VAC; VAC; VDC; VDC -S /250/480 VAC; VDC; Adjustable differential -GH 1 125VAC; gold contacts -AA Hermetically sealed; 4 125/250 VAC -CC Hermetically sealed; /250 VAC -HH Hermetically sealed; 5 125/250 VAC -GH Hermetically sealed; VAC; gold contacts Temperature Range Range Adjustable Range Media Temperature Limit (Proof) F Low High C Low High F Low High C Low High Differential 1 (Approx.) Liquid F C to 2.5 to to 2.5 to to 2.5 to to to to to 2.2 Calibrated Dial Adjustment Calibrated 5 Subdivision 200 Span 5 Subdivision 140 Span 10 Subdivision 280 Span Options -RD 2 Manual reset NEMA 4X enclosure -FX 3 (consult factory) -SXXX 5 Factory pre-set (consult factory) Armor Options Blank -A Wetted Material Blank S Blank if not required 302 stainless steel armor Capillary Length Blank 6 foot capillary foot capillary foot stainless steel capillary Copper sensor 304 stainless steel 3211 Fruitland Avenue Los Angeles, CA Fax: See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0021-N 06/ Printed in the U.S.A. 13

14 Local Mount Temperature Switches ML1H, L2H Features Reliable & accurate Local sensing NEMA 4 UL, CSA & CE approved Single or dual switching Applications Oil & gas Mining Tanks and reservoirs Compressors Plastic machinery Factory automation Process equipment Machine tools and industrial equipment General Specifications* Accuracy: (Repeatability) Switch: Electrical Characteristics: Wetted Parts: Electrical Connection: Electrical Ratings: Enclosure/Housing: Local Mount: ±1% of mid-60% of full range. At constant ambient ±0.5% of full scale. (Knob indication is reference only) Single: 1 SPDT Dual switching: 2 independent SPDT circuits All models incorporate Underwriters Laboratories, Inc. and CSA listed single pole double throw snap-action switching elements. Switches may be wired normally open or normally closed. Brass or 304 stainless steel Single: 3-pin terminal strip Dual: 6-pin terminal strip AC value at 50% power factor 10 amps 125, 250 volts AC, 3 amps 480 volts AC. Automatically reset by snap-action of switch. Water-tight and dust-tight indoor and outdoor (NEMA 4) / oil-tight and dust-tight indoor (NEMA 13). Immersion length 2-1/16 inches Approvals/Listings: UL: CSA: Temperature Range: Adjustment: Weight: Underwriters Laboratories, Inc. and Canadian Standard Assoc. are listed under temperature indicating and regulating equipment. File No. E56247, Guide No. XAPX File No. LR34555, Guide 400-E-O Class 4813 See product configurator. Tamper resistant external adjustment. Turn knob clockwise to increase setpoint. (Knob indication is reference only) Single: approximate 1.5 lbs. Dual: approximate 3.0 lbs. * See Product Configurator for additional options. Wiring Diagram Wiring Code Single Dual Lead Circuit #1 Circuit #2 Normally Closed Blue Orange Common Purple Brown Normally Open Red Yellow NO (Red) C (Purple) NC (Blue) T NO (Red) C (Purple) NC (Blue) NO (Yellow) C (Brown) NC (Orange) ML1H L2H T 14

15 Local Mount Temperature Switches Technical Drawing ML1H, L2H L2H 1-5/8 (41.2) ML1H 7 Dimensions in inches (mm) Product Configurator Example H M L1 H -HH 202 S -WS -FX H Blank M Blank Hermetically sealed limit switch option - Class I, Division II (requires AA, CC, GH or HH limit switch 60 Ta max) Standard Single switch models Dual switch models Sensor Switch L1 Single set point (SPDT) L2 Dual set point (2 SPDT) Limit Switch 1 -H /250 VAC; VAC (standard) -B /250/480 VAC; VAC; VDC; VDC -G /250/480 VAC; VAC; VDC; MANUAL RESET -J /250 VAC; VAC (with elastomer boot) -L /250/480 VAC; VDC; VDC -M /250 VAC; VAC; VDC; VDC -S /250/480 VAC; VDC; Adjustable differential -GH 1 125VAC; Gold Contacts -AA Hermetically sealed; 4 125/250 VAC -CC Hermetically sealed; /250 VAC -HH Hermetically sealed; 5 125/250 VAC -GH Hermetically selaed; VAC; gold contacts Options -RD 2,3 -FX 4 -SXXX Thermowell -W -WS -Z18 Manual reset (use with G limit switch) NEMA 4X enclosure Factory preset Brass local mount thermowell 316 stainless steel local mount thermowell Replacement temperature switch for thermowell models, without the thermowell. Wetted Material Blank Blank if brass 304 stainless steel S sensor Enclosure H NEMA 4 enclosure NOTES: 1 Changing limit switch will effect dead band; See sales drawing. 2 Use G limit switch for single set point models that need this option. When selecting the manual reset option on dual setting switches (L2H), the manual reset limit switch will be on the high circuit. The low circuit limit switch must be specified by the customer. 3 Not available with hermetically sealed limit switches. 4 Add S wetted material. FX models require stainless steel sensor. Range Adjustable Range Media Temperature Limit (Proof) Differential (Approx.) 1 Low High Low High Low High Low High F C F +75 F -45 C +24 C -100 F +250 F -73 C +121 C 1 to 3.5 to F +140 F -9 C +60 C -100 F +250 F -73 C +121 C 1 to 3.5 to F +200 F +24 C +93 C -100 F +250 F -73 C +121 C 1 to 3.5 to F +225 F +38 C +107 C -100 F +400 F -73 C +205 C 1 to 3.5 to F +200 F -45 C +93 C -100 F +250 F -73 C +121 C 1 to 3.5 to F +350 F +38 C +177 C -100 F +400 F -73 C +205 C 1 to 3.5 to F +450 F +66 C +232 C 0 F +500 F -18 C +260 C 3 to to Fruitland Avenue Los Angeles, CA Fax: See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0020-L 01/ Printed in the U.S.A. 15

16 Explosion Proof Temperature Switches Series T1X, T2X, L1X Features Explosion-proof for hazardous locations High accuracy Remote, local or ambient sensing UL, CSA & ATEX approved NEMA 4, 7, 9 & IP66 Applications Oil & gas Heat tracing Printing machinery Compressors Process equipment Machine tools and industrial equipment L1X T2X General Specifications* Accuracy: (Repeatability) Switch: Single Setting: Dual Setting: Electrical Characteristics: Wetted Parts: Electrical Connection: Electrical Ratings: ±1% of mid-60% of full range. At constant ambient +/- 0.5% of full scale. (Knob indication is reference only) One (1) single pole double throw (SPDT) circuit. Two (2) independent single pole double throw (SPDT) circuits. All models incorporate Underwriters Laboratories, Inc. and CSA listed single pole double throw snap-action switching elements. Switches may be wired normally open or normally closed. 304 stainless steel Single: 3-pin terminal strip Dual: 6-pin terminal strip AC value at 75% power factor 10 amps 125, 250 volts AC, 3 amps 480 volts AC. Automatically reset by snap-action of switch. Enclosure/Housing: Class I, Division 1 & 2 NEMA 4, 7, & 9 Tamper-proof external adjustment, enclosed terminal strip. Local Mount: Bulb & Capillary: Approvals: UL (standard): CSA (standard): ATEX (optional): Temperature Range: Adjustment: Standard Options/ Modifications: Weight: Immersion length 2-1/16 inches 6 foot length standard. Underwriters Laboratories, Inc. and Canadian Standard Assoc. are listed under Temperature indicating and regulating equipment, for use in hazardous locations, Class I, Groups B, C and D; Class II, Groups E, F and G. File No. E58658, Guide No. XBDV File No. LR34556, Guide 400-E-O.8. Class EX models are ATEX marked as follows: 0081, ISSeP 08 ATEX024X II 2 G D, Ex db II C T6 Gb Ex tb IIIC T80 C Db IP66-40 C Tamb +75 C See product configurator Tamper resistant external adjustment. Turn knob clockwise to increase setpoint. (Knob indication is reference only) For thermowels, split nuts and union connections, see accessory pages. Single - approximate 4.0 lbs. Dual - approximate 4.5 lbs. * See Product Configurator for additional options. Wiring Code Lead Circuit #1 Circuit #2 Normally Closed Blue Orange Common Purple Brown Normally Open Red Yellow Wiring Diagram NO (Red) C (Purple) NC (Blue) T NO (Red) C (Purple) NC (Blue) NO (Yellow) C (Brown) NC (Orange) T 16

17 Explosion Proof Temperature Switches Series T1X, T2X, L1X Technical Drawing L1X T1X Product Configurator Hermetically Sealed H Sensing Type T L Set Point Limit Switch 2 -H /250 VAC; VAC (standard) -B /250/480 VAC; VAC; VDC; VDC -G /250/480 VAC; VAC; VDC; MANUAL RESET (only available for T2X) -J -L -M -S -GH -AA -CC -HH Remote bulb & capillary Local mount 1 Single setpoint (SPDT) 2 1 Dual setpoint (2 SPDT) Enclosure X Hermetically sealed limit switch option - Class I, Division II (requires AA, CC, or HH limit switch) NEMA 4, 7, & 9 explosion proof enclosure (Standard) /250 VAC; VAC (with elastomer boot) /250/480 VAC; VDC; VDC /250 VAC; VAC; VDC; VDC /250/480 VAC; VDC; adjustable differential VAC; gold contacts Hermetically sealed; 4 125/250 VAC Hermetically sealed; /250 VAC Hermetically sealed; 5 125/250 VAC 1 Not available with local mount version. 2 Changing limit switch will effect deadband; See sales drawing Example H T 1 X -HH 251 S -12 -A Wetted Material Blank S Capillary Length Blank 3 When selecting the manual reset option on dual setting switches (T2X), the manual reset limit switch will be on the high circuit. The low circuit limit switch must be specified by the customer. Only available with T2X. 4 When selecting the S adjustable differential limit switch option on a dual setting switch (T2X), a standard H switch will be paired with an S switch. Dual S pricing will apply. Copper sensor 304 stainless steel 6 foot capillary foot capillary foot stainless steel capillary Temperature Range Options 3211 Fruitland Avenue Los Angeles, CA Fax: Thermowell (Local Mount only) See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0022-O 06/ Printed in the U.S.A. -RD 3 -EX 6 -Sxxx -WS Manual reset (must use when selecting G limit switch option) Only available on T2X ATEX certification Factory pre-set (consult factory) 316 stainless steel thermowell (local mount only) -W Brass local mount Thermowell Armor Option (Bulb & Capillary only) Blank Blank if not required -A 302 stainless steel armor Dimensions in inches (mm) Remote sensor ranges Adjustable Range Media Temperature Limit (Proof) Differential (Approx.) 2 Range Low High Low High Low High Low High F C F +150 F -45 C +66 C -100 F +200 F -73 C +93 C 1 to 2.5 to F +250 F +10 C +121 C -100 F +300 F -73 C +149 C 1 to 2.5 to F +350 F +66 C +177 C -100 F +400 F -73 C +205 C 1 to 2.5 to F +440 F +149 C +227 C 0 F +650 F -18 C +343 C 2 to to F +600 F +160 C +316 C 0 F +650 F -18 C +343 C 2 to to 2.2 Local mount sensor ranges Adjustable Range Media Temperature Limit (Proof) Differential (Approx.) 2 Range Low High Low High Low High Low High F C F +75 F -45 C +24 C -100 F +250 F -73 C +121 C 1 to 3.5 to F +140 F +9 C +60 C -100 F +250 F -73 C +121 C 1 to 3.5 to F +200 F +24 C +93 C -100 F +250 F -73 C +121 C 1 to 3.5 to F +225 F +38 C +107 C -100 F +400 F -73 C +205 C 6 to to F +200 F -45 C +93 C -100 F +250 F -73 C +121 C 1 to 3.5 to F +350 F +38 C +177 C -100 F +400 F -73 C +205 C 6 to to F +450 F +66 C +232 C 0 F +500 F -18 C +260 C 3 to to Add S wetted material adder and A armor adder to this. Capillary length 25 requires stainless steel capillary and armor. 6 ATEX certification is only available with S stainless steel wetted material 17

18 Temperature General Purpose Switch Series TPR Features High accuracy NEMA 4X & IP 65 UL, CSA and CE approved Low cost Applications Heat trace Water equipment Process equipment Machine tools and industrial equipment Freeze protection General Specifications* Accuracy: Switch: Type: Rating: Electrical Characteristics: Wetted Parts: Electrical Connection: Enclosure Rating: Enclosure/Housing: ±4 F * See Product Configurator for additional options. Single pole double throw (SPDT), prewired snap action /250/480 VAC All models incorporate Underwriters Laboratories, Inc. and CSA listed single pole double throw snap-action switching elements. Switches may be wired normally open or normally closed. Tin plated copper sensor & capillary 1-1/8 (28mm) hole for 3/4 NPT conduit hub 12, 14 AWG stranded copper wire NEMA 4X Polycarbonate (black) Bulb and Capillary: Bulb: Capillary Length: System Pressure (max): Fill: Approvals: Temperature Range: Ambient Temperature: Vibration: Shock: Weight: 3-1/8 (79mm), 1/16 (10mm) dia. 30 (762mm) or 120 (3048mm) 300 psi without thermowell Silicone oil-filled UL listed, file E56247 CSA certified, file LR EN/RFi: to EN to 160 F (-40 to 71 C) Fixed setpoint factory set at 40 F Contact closes on decreasing temperature -30 to 140 F (-34 to 60 C) 10 g s Hz, MIL-STD 202F 50 g s, 10 ms, MIL-STD 901C 1.1 lbs. (0.5 kg) Wiring Code Lead Normally Closed Common Normally Open Circuit Blue Purple Red Media Factory Differential Catalog Temperature Preset (approximate) Number Limits -40 to 160 F 40 F 10 F (-40 to 71 C) (4.4 C) (5.6 C) TPR-L1N-3X-Q10 18

19 General Purpose Switch Series TPR Technical Drawing Dimensions in inches (mm) Product Configurator Example T P R -L 1 N -3X -Q10 Basic Configurator T Temperature switch -Q10 Heat tracing model Basic Configurator P Polycarbonate plastic NEMA 4X enclosure Basic Configurator R Remote bulb & capillary Bulb & Capillary Length -3X 3 foot bulb & capillary sensor -10X 10 foot bulb & capillary sensor Limit Switch -L /250/480 VAC; standard Temperature Range Range Fixed Set-point (Decreasing) Media Temperature Limit (Proof) Differential (Approx.) Liquid Wetted Material F C F Low High C Low High F C N Tin plated copper sensor Fruitland Avenue Los Angeles, CA Fax: See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0025-D 09/ Printed in the U.S.A. 19

20 Temperature Temperature Switch Series THR, THL Features High accuracy Line or ambient sensing NEMA 4X & IP 65 UL, CSA and CE approved Applications Heat tracing Process equipment Machine tools and industrial equipment General Specifications* Accuracy: Switch: Type: ±1% of full scale SPDT, prewired snap action Rating: /250/480 VAC Electrical All models incorporate Underwriters Characteristics: Laboratories, Inc. and CSA listed single pole double throw snap-action switching elements. Switches may be wired normally open or normally closed. Electrical Connection: 3/4 NPT female conduit connection. 3 pole terminal block accepts AWG wire. Electrical Ratings: /250/480 VAC Enclosure Rating: NEMA 4X Enclosure/Housing: Anodized die cast aluminum Green polyurethane coated Other exposed parts: stainless steel Bulb and Capillary: Material: 316L stainless steel Approvals: UL listed, file CSA certified, file LR EMI/RFI: to EN Temperature Range: 15 F F (-9 C C) Ambient Temperature: Adjustment: Vibration: Shock: Standard Options: R**(Option): R2 (Option): Weight: See table below (media temperature limit) External adjustment knob. Turn clockwise to decrease setpoint 10 g s Hz, MIL-STD 202F 50 g s, 10 ms, MIL-STD 901C DPST relay switch 22 VAC Relay coil: 120 VAC, 4VA 120/240/277 VAC Relay coil: 240 VAC, 4VA 1.9 lbs. (0.9 kg) Bulb: 7-3/4 (197mm), 5/16 (8mm) dia. Capillary Length: System Pressure (max): Fill: 10 (3m), remote mount 300 psi without thermowell Silicone oil-filled * See Product Configurator for additional options. ** Must specify; close on rising or falling temperature Media Adjustabl Differential Sensing Catalog Temperature Range (approximate) Location Number Limits -40 to 420 F 25 to 325 F 10 F Line Sensing THR-L2S-10X-Q10 (-40 to 215 C) (-4 to 163 C) (5.6 C) T-stat -40 to 160 F 15 to 140 F 10 F Ambient THL-L1S-X-Q10 (-40 to 71 C) (-9 to 60 C) (5.6 C) Sensing T-stat Factory Set Point 125 F ± 5 decreasing 40 F ± 4 decreasing 20

21 Temperature Switch Series THR, THL Technical Drawing Dimensions in inches (mm) Product Configurator Example TH R -L 2 S -10X -Q10 Base Configurator TH Aluminum NEMA 4X enclosure -Q10 Heat tracing model (standard) L 1 R 2 Limit Switch Local mount for ambient sensing Remote bulb & capillary -L /250/480 VAC Bulb & Capillary Length; Switch -X For THL models (with NEMA 4X enclosure) -10X 10 ft bulb & capillary for THR models -10R2X 22A DPST relay3, 10 ft bulb & capillary for THR models Temperature Range Range Adjustable Range Media Temperature Limit (Proof) F C F C Low High Low High Low High Low High Differential (Approx.) Liquid F C Wetted Material S Stainless steel sensor 1 Use Temperature Range 1 for local sensing applications 2 Use Temperature Range 2 for remote sensing applications 3 DPST switch, /240/277 VAC. Relay Coil: 240 Vac, 4 VA. Contacts close on falling temperature Fruitland Avenue Los Angeles, CA Fax: See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0024-E 09/ Printed in the U.S.A. 21

22 Explosion Proof Temperature Switch Series TXR, TXL Features Explosion-proof High accuracy Line or ambient sensing UL, CSA & ATEX approved Applications Heat tracing Hydraulic power units Combustion engines Compressors Machine tools and industrial equipment Process equipment General Specifications* Accuracy: Switch: Type: Rating: Electrical Characteristics: ±1% of full scale Single pole double throw (SPDT), prewired snap action /250/480 VAC All models incorporate Underwriters Laboratories, Inc. and CSA listed single pole double throw snap-action switching elements. Switches may be wired normally open or normally closed. Electrical Connection: 3/4 NPT female conduit connection. 3 pole terminal block accepts AWG wire. Enclosure Ratings: NEMA 4, 7, 9, & IP65 Enclosure/Housing: Anodized aluminum, explosion proof, painted silver Bulb and Capillary: Material: 316L stainless steel Bulb: 8 (203mm), 5/16 (8mm) dia. Approvals: FM, UL file E58658, CSA - file LR Division 1 and 2, Class I, Group B, C & D Class II, Group E, F & G, Class III. CE 0081, LCIE 07 ATEX 6092X II 2 G D, Ex d IIC T6, Ex td A21 IP6X T80 C -40 C Tamb +60 C (EX NEPSI, GOST-R) Temperature Range: -40 to 160 F (-40 to 71 C) Ambient Temperature: -40 to 140 F (-40 to 60 C) Adjustment: External adjustment knob. Turn knob clockwise to decrease setpoint ENI/RFI: to EN Vibration: 10 g s Hz, MIL-STD 202F Shock: 50 g s, 10 ms, MIL-STD 901C Standard Options: -R (suffix): Double pole single throw (DPST) relay /240/277 VAC. Contacts close on falling temperature. Relay Coil: 120 VAC, 4VA. Example: TXR-L2S-10R-Q10 Weight: 3.8 lb (1.7 kg) Capillary Length: 10 (3m), remote mount only System Pressure (max): 300 psi without thermowell Fill: Silicone oil-filled * See Product Configurator for additional options. Media Temperature Limits -40 to 420 F (-40 to 215 C) -40 to 160 F (-40 to 71 C) Adjustable Range 25 to 325 F (-4 to 163 C) 15 to 140 F (-9 to 60 C) Differential (approximate) 10 F (5.6 C) 10 F (5.6 C) Sensing Location Line Sensing T-stat Ambient Sensing T-stat Catalog Number TXR-L2S-10-Q10 TXL-L1S-Q10 22

23 Explosion Proof Temperature Switch Series TXR, TXL Technical Drawing 9/32 1-7/32 (30) Dimensions in inches (mm) Product Configurator Example TX R -L 2 S -10 -Q10 Base Configurator T X R 1 L 2 Temperature switch NEMA 4, 7, 9 & IP65 explosion proof enclosure Limit Switch Remote bulb & capillary Local mount for ambient sensing -L /250/480 VAC S -Q10 Heat tracing model (standard) Stainless steel sensor For TXL models ft bulb & capillary for TXR models -10R2 Wetted Material Temperature Range Bulb & Capillary Length & Switch 22A DPST relay 3 with 10 ft bulb & capillary. (For TXR models) NOTES: 1 Use temperature range 2 for remote sensing applications 2 Use temperature range 1 for local sensing applications 3 DPST switch, /240/277 VAC. Relay Coil: 240 Vac, 4 VA. Contacts close on falling temperature. Adjustable Range Media Temperature Limit Differential (Proof) (Approx.) Liquid Range F C F C F C Low High Low High Low High Low High Fruitland Avenue Los Angeles, CA Fax: See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0026-H 04/ Printed in the U.S.A. 23

24 Temperature Bi-Metallic Switch Series ML1S Features Bi-metallic sensor Compact design NEMA 4 One piece design Applications Air compressors Medical compressors Process equipment Water treatment Mining Machine tools and industrial equipment General Specifications* Accuracy: See adjacent table Switch: SPST-NO or SPST-NC Wetted Parts: Brass Electrical Connection: 18, 18 AWG PTFE free leads Electrical Ratings: 125 Vac; 250 Vac Enclosure/Housing NEMA 4 Process Connection: 1/2 NPT Conduit Connection: 1/2 NPT Proof Pressure: 500 psi Cycle Life: 100,000 cycles 1 Approvals: CE qualified UL and CSA (curus) Temperature Range: 50 F F Proof Temperature: 340 F Warranty: Weight: 1 year 0.15 lb. 1 Differential depends on service conditions and test methods * See product configurator for additional options. 24

25 Bi-Metallic Switch Series ML1S Technical Drawing Number Shown = Set Point 1/2 NPT 7/8 HEX 1/2 NPT TEMPERATURE SENSING PROBE 11/16 (17.8) 18 AWG. BLACK PTFE LEADS 18 LONG STANDARD 3-1/2 (REF.) (88.9) 1-1/2 (38.1) 2-1/8 (53.3) Dimensions in inches (mm) Product Configurator Example ML 1 S I -C -W36 Prefix ML Miniature local thermowell Switch 1 Single SPST switch point Housing S Stripped model Option -WXXX Extra wire length (XXX = inches) Setpoint* ºF setpoint ºF setpoint ºF setpoint ºF setpoint ºF setpoint ºF setpoint ºF setpoint ºF setpoint ºF setpoint ºF setpoint Set Point Direction -D Decreasing (falling) temperature -I Increasing (rising) temperature Contact Form -O Normally open -C Normally closed * NOTE: Consult factory for ranges not listed. Minumum order quantity - 20 pieces for non-standard ranges. Ranges specified in 5 increments. Example: -250 = 250 F 3211 Fruitland Avenue Los Angeles, CA Fax: See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0023-D 09/ Printed in the U.S.A. 25

26 Global Presence Global Presence Barksdale Inc Fruitland Ave. Los Angeles, CA U.S.A. Phone: (800) Fax: (323) Barksdale GmbH Dorn-Assenheimer Strasse Reichelsheim, Germany Phone: (49) (main offi ce) (49) (sales) Fax: (49) / Barksdale China 33F Huaihai Plaza 1045 Central Huaihai Road Shanghai , China Phone: (86) Fax: (86) Barksdale India SF- 43, Ansal Fortune Arcade Sector 18 India Noida Phone: (91) Fax: (91) See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #M0066-D 09/ Printed in the U.S.A.

Temperature Switches

Temperature Switches Temperature Switches Temperature Switches c Pressure - Electronic Pressure Switches - Mechanical Pressure Switches - Pressure Transducer c Valves & Regulators c Temperature c Level c Flow c Air Suspension

More information

u Electronic Products u Pressure Transducers u Mechanical Pressure Products u Valves & Regulators u Temperature Products u Level Products u Air

u Electronic Products u Pressure Transducers u Mechanical Pressure Products u Valves & Regulators u Temperature Products u Level Products u Air Air Suspension Air Suspension Valves Valves u Electronic Products u Pressure Transducers u Mechanical Pressure Products u Valves & Regulators u Temperature Products u Level Products u Air Suspension Valves

More information

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX ATEX Type Certification marking for type L1X-EX, T1X-EX, T2X-EX Type of protection "d" explosion-proof enclosure Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

More information

Product overview. Product overview. Control. Control. every move. Pressure Temperature Level Flow

Product overview. Product overview. Control. Control. every move. Pressure Temperature Level Flow Product overview Product overview Control Control every move Pressure Temperature Level Flow Barksdale Controls The business of critical controls Market-focused. Technology-driven. Customer-intimate. These

More information

Fluid Power Fluid Power

Fluid Power Fluid Power Fluid Power Fluid Power Control Control every move Barksdale State-of-the-Art Solutions Barksdale State-of-the-Art Solutions Today s markets demand flexible and dynamic suppliers of innovative products,

More information

Product overview. Product overview. Control. Control. every move. Pressure Temperature Level Flow

Product overview. Product overview. Control. Control. every move. Pressure Temperature Level Flow Product overview Product overview Control Control every move Pressure Temperature Level Flow Global Presence Global Presence Barksdale Inc. 3211 Fruitland Avenue Los Angeles, CA-90058-0843 U.S.A. Phone:

More information

Series 1. Series 1 Pressure Switch. Pressure Switches Inc. Quality Pressure Solutions. Pressure Switches 1 G 10 N Key Features.

Series 1. Series 1 Pressure Switch. Pressure Switches Inc. Quality Pressure Solutions. Pressure Switches 1 G 10 N Key Features. Model 1A 1C 1G 1Z 1P 1H Inc. Series 1 Series 1 Pressure Switch High, Low, Differential & Vacuum Pressure Switch options available All Anodized Aluminum Construction Multiple s Available UL & cul Approved

More information

UNITED ELECTRIC 100 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches Adjustable Ranges 30 Vac to 5000 PSI, -180 to 650 o F

UNITED ELECTRIC 100 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches Adjustable Ranges 30 Vac to 5000 PSI, -180 to 650 o F UNITED ELECTRIC 100 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches Adjustable Ranges 30 Vac to 5000 PSI, -180 to 650 o F DESCRIPTION The 100 Series is a cost-effective pressure and temperature

More information

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter BULLETIN NO. 220/11 (SUPERSEDES BULLETIN NO. 220/06) Mid-West Instrument Piston Type Model 220 Hazardous Locations Indicating / Non-Indicating Differential Pressure Switch or Transmitter Low cost piston

More information

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter BULLETIN NO. 240/11 (SUPERSEDES BULLETIN NO. 240/06) Mid-West Instrument Diaphragm Type Model 240 Hazardous Locations Indicating / Non-Indicating Differential Pressure Switch or Transmitter Field wireable

More information

Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures

Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures S-SERIES Pressure Switches Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with, or s Features: Set point repeatability, +1% of operating range. All wiring terminals, adjustments

More information

Mini temperature switch Stainless steel switch enclosure Model TXS

Mini temperature switch Stainless steel switch enclosure Model TXS Mechatronic temperature measurement Mini temperature switch Stainless steel switch enclosure Model TXS WIKA data sheet TV 31.70 Process Mini Series Applications Temperature monitoring and control of processes

More information

^ % P-SERIES Temperature Switches. Switches for -30 through 510 F with Adjustable Set Points and Fixed or Adjustable Deadband

^ % P-SERIES Temperature Switches. Switches for -30 through 510 F with Adjustable Set Points and Fixed or Adjustable Deadband P-SERIES Temperature Switches Switches for -30 through 5 F with Adjustable Set Points and Fixed or Adjustable Features: Set point repeatability, + F (/2 C). All wiring terminals, adjustments and visual

More information

Mechanical Pressure Products

Mechanical Pressure Products Mechanical Pressure Products Mechanical Pressure Products u Electronic Products u Pressure Transducers u Mechanical Pressure Products u Valves & Regulators u Temperature Products u Level Products u Air

More information

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment CLARK SOLUTIONS 400 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches 1,2 & 3 Switch output, Adjustable Ranges 30 Vac to 6000 PSI, -180 to 650 o F DESCRIPTION The 400 Series is a versatile family

More information

Compact temperature switch Model TCS

Compact temperature switch Model TCS Mechatronic temperature measurement Compact temperature switch Model TCS WIKA data sheet TV 31.64 Process Compact Series Applications Temperature monitoring and control of processes Safety-critical applications

More information

Data Sheet. A-Series Miniature Watertight Pressure Switches

Data Sheet. A-Series Miniature Watertight Pressure Switches A-Series Miniature Watertight Pressure Switches FEATURES Compact size 36 Stainless steel construction Pressure ranges from vacuum to 000 bar (5.000 psi) Factory set or field adjustable setpoints Wide operating

More information

9012G Pressure and 9016G Vacuum Switches

9012G Pressure and 9016G Vacuum Switches Selection Guide 90G and 906G Vacuum Switches Type of installation Control circuits Power circuits Applications Media controlled Type of operation Air, water, hydraulic oils, () gases, steam Fixed differential:

More information

PISTON STYLE GAUGE. Mid-West Instrument

PISTON STYLE GAUGE. Mid-West Instrument PISTON STYLE GAUGE Mid-West Instrument 1 BULLETIN NO. 120/11 (SUPERSEDES BULLETIN NO. 120/02) Mid-West Instrument Piston Type Differential Pressure Gauges Switches & Transmitters Model 120 A low cost differential

More information

Data Sheet. A-Series Miniature Watertight Pressure Switches. Factory set or field adjustable

Data Sheet. A-Series Miniature Watertight Pressure Switches. Factory set or field adjustable FEATURES Compact size 36 stainless steel construction Pressure ranges from vacuum to 5,000 psi Factory set or field adjustable setpoints Wide operating temperature range ( 40 C to 00 C) Precision snap-acting

More information

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA Mechatronic pressure measurement Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA WIKA data sheet PV 34.38 Applications Pressure monitoring and control of processes

More information

Compact differential pressure switch Models DC, DCC

Compact differential pressure switch Models DC, DCC Mechatronic pressure measurement Compact differential pressure switch Models DC, DCC WIKA data sheet PV 35.40 Process Compact Series Applications Differential pressure monitoring and control of processes

More information

short form catalog SFC 07

short form catalog SFC 07 short form catalog Electronic and Electromechanical Switches for Pressure, Differential Pressure, and Temperature Pressure Transmitters and Transducers Industrial Temperature Sensors SFC 07 is a privately

More information

Bourdon Tube Pressure Switches

Bourdon Tube Pressure Switches DA /DS Bourdon Tube es Visible setpoint, adjustable deadband, snap action switch pressure ranges to 000 psi Weather-Proof Types DAW, DSW, DRW -/1 2-1/1 REAR MOUNTING FLANGE ().20 DIA. HOLES AT 120 ON -1/2

More information

Switch to. Generation NEW Electronic Level. One Series for. Pressure Temperature Level

Switch to. Generation NEW Electronic Level. One Series for. Pressure Temperature Level Switch to Generation 000 NEW Electronic Level One Series for Temperature Level Quality by design Generation 000 BPS000 / BTS000 / BLS000 Wide range of performance Simple configuration allows customers

More information

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction K Pressure Controller Cataloge Code Characteristics Index K00-2 Pressure Controller Brief Introduction KC32 Screw Tube Differential Pressure Controller K01 KY10 Bellows Type Differential Pressure Controller

More information

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit: Mid-West Instrument

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit:   Mid-West Instrument PISTON STYLE GAUGE For Installation and Operation Manuals Please Visit: www.midwestinstrument.com/literature Mid-West Instrument BULLETIN NO. 120/11 (SUPERSEDES BULLETIN NO. 120/02) Mid-West Instrument

More information

PPT 802, Proximity Probe Transducer System

PPT 802, Proximity Probe Transducer System PPT 802, Proximity Probe Transducer System PPH 080 : Proximity Probe Head PEC 036 : Probe Extension Cable PRD 020 : Proximity Probe Driver Feature Non-contacting measurement system based on eddy current

More information

SP/SF Series Flow Switches

SP/SF Series Flow Switches ISO-9001:2000 certified SP/SF Series Flow Switches More than just another level measurement company. Aplus Finetek Sensor, Inc. PRODUCT INTRODUCTION SP SERIES OPERATING PRINCIPLE SP SERIES The SP Series

More information

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications Explosion Proof Adjustable Flow Switch with Right Angle Flow Key Features Field adjustable Infinite flow range Extremely accurate and sensitive Low pressure drop UL recognized for hazardous location ATEX

More information

M-60X. Explosion Proof Flowswitch with In-line Flow. Description. Key Features. Operating Principle. Applications. Custom Version Available

M-60X. Explosion Proof Flowswitch with In-line Flow. Description. Key Features. Operating Principle. Applications. Custom Version Available Explosion Proof Flowswitch with In-line Flow Key Features Well suitable for corrosive and noncorrosive liquids or gases UL recognized for hazardous location ATEX certified for intrinsic safety and encapsulation

More information

Gas-actuated temperature switch Stainless steel switch enclosure Model TWG

Gas-actuated temperature switch Stainless steel switch enclosure Model TWG Mechatronic Electrical temperature measurement Gas-actuated temperature switch Stainless steel switch enclosure Model TWG WIKA data sheet TV 31.60 Process Performance Series Applications Temperature monitoring

More information

VACUUM A RESOURCE FOR EVERYONE

VACUUM A RESOURCE FOR EVERYONE Vacuum grippers VACUUM PRODUCTS INNOVATORS IN VACUUM TECHNOLOGY CATALOG VERSION 5.0 VACUUM A RESOURCE FOR EVERYONE www.piab.com Accessories Suction cups Vacuum pumps PVA VACUUM SWITCHES, INDUCTIVE UNIVERSAL

More information

Mini pressure switch Stainless steel switch enclosure Model PXS

Mini pressure switch Stainless steel switch enclosure Model PXS Mechatronic pressure measurement Mini pressure switch Stainless steel switch enclosure Model PXS WIKA data sheet PV 34.36 Process Mini Series Applications Pressure monitoring and control of processes Safety-critical

More information

Integrated Control modules

Integrated Control modules .60.0 Rev. 0 Page of 9 Integrated Control modules QC, QC2 and QC Features: - Basic actuator functions for: - Spring return applications, or - Double acting applications or, - Double acting Fail in Last

More information

Technical Datasheet. GR Series - Flameproof Pressure Switch Models: GR2 & GR4. GR Series. Key Features. Series Overview. Product applications

Technical Datasheet. GR Series - Flameproof Pressure Switch Models: GR2 & GR4. GR Series. Key Features. Series Overview. Product applications Technical Datasheet - Flameproof Pressure Switch Key Features Compact and rugged design. Weatherproof IP66/NEMA 4. ATEX Flameproof CENELEC EEx d IIC option. ATEX Intrinsically Safe ATEX Ex ia IIC option.

More information

Compact pressure switch Model PCS

Compact pressure switch Model PCS Mechatronic pressure measurement Compact pressure switch Model PCS WIKA data sheet PV 33.30 for further approvals see page 4 Process Compact Series Applications Pressure monitoring and control of processes

More information

Integrated Control modules

Integrated Control modules .604.0 - Rev: 6, Page of Integrated Control modules QC4, QC42 and QC43 Features: - Basic actuator functions for: - Spring return applications, or - Double acting applications or, - Double acting Fail in

More information

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH INSTALLATION AND OPERATION MANUAL PN 610-0006 Rev E WARNING CAUTION SPECIAL CONDITIONS FOR SAFE USE NOTE Manual No. 610-0006 Rev

More information

Adjustable Dead Band Pressure Switches

Adjustable Dead Band Pressure Switches The adjustable dead band pressure switch should be used when there is a requirement for an adjustable and wide dead band between the increasing and decreasing set points. Function Alarm: Hi Lo Control:

More information

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters Electronic Pressure Catalog > Hazardous Area > E-10, E-11 Type E-10, E-11 Hazardous Area Explosion-proof Transmitters Meets ANSI / ISA 12.27.01-2003 single seal requirements - no dual seal required Applications

More information

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 120

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 120 BULLETIN NO. 120/11 (SUPERSEDES BULLETIN NO. 120/02) Piston Type Differential Pressure Gauges Switches & Transmitters A low cost differential pressure gauge for use in measuring the pressure drop across

More information

Features and benefits. Normally open, normally closed contact logic

Features and benefits. Normally open, normally closed contact logic Pressure Switches Reliable pressure control by means of on / off electrical switch Normally open, normally closed contact logic Commercial and residential air conditioning systems The reliable and durable

More information

Introduction. Series P100. Encapsulated Pressure Control. Auto-reset Standard Duty and Heavy Duty. Manual reset Standard Duty. Feature and Benefits

Introduction. Series P100. Encapsulated Pressure Control. Auto-reset Standard Duty and Heavy Duty. Manual reset Standard Duty. Feature and Benefits PSC9919 European Refrigeration Controls Catalogue Catalog Section 6 Product Bulletin P100 Series P100 Encapsulated Pressure Control. Auto-reset Standard Duty and Heavy Duty. Manual reset Standard Duty.

More information

Vibralert Mechanical Switch Model 5550

Vibralert Mechanical Switch Model 5550 Vibralert Mechanical Switch Model 5550 APPLICATION TIPS -Lowest cost vibration protection; -Baseplates available to accomodate most previous Metrix or competitor s switch models for easy retrofit. -Watertight

More information

Switches. SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY 115VAC, 28VDC)

Switches. SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY 115VAC, 28VDC) SWITCH SELECTION GUIDE Toggle Switches SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY (Resistive @ 115VAC, 28VDC) T1 2 or 3 Position, Momentary, 8A MIL-PRF-83731 15/32" or 1/4" dia.

More information

Remote Temperature Controllers. Quick Selection Guide

Remote Temperature Controllers. Quick Selection Guide Remote Temperature Controllers Quick Selection Guide A Complete Selection For A Wide Range Of Applications Electronic Standalone Controllers T775 Provide on/off, modulating, or reset control in applications

More information

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B) 4 Engineering Information Principles of Operation A solenoid valve is a combination of two basic functional units: A solenoid (electromagnet) with its core A valve body containing one or more orifices

More information

M-100X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

M-100X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications Explosion Proof Adjustable Flow Switch with Right Angle Flow Key Features Field adjustable Infinite flow range Extremely accurate and sensitive Low pressure drop UL recognized for hazardous location ATEX

More information

TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS

TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS OSUR CL HA ES EN KILLARK Z LO C SJIC SERIES TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS Screw cover style, with or without continuous hinge 3/16 (5mm) wide flat flange for maximum gasket surface

More information

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

HKH Series. HAZCON Controls for Harsh and Hazardous Environments HKH Series HAZCON Controls for Harsh and Hazardous Environments Z A H LO C NON-METALLIC DIN RAIL MOUNT Component Mounting Rail Optional Customer I.D. Nameplate Optional Legend Plate Explosion Protective

More information

Adjustable Dead Band Pressure Switches

Adjustable Dead Band Pressure Switches Form 281 The adjustable dead band pressure switch should be used when there is a requirement for an adjustable and wide dead band between the increasing and decreasing set points. Function Alarm: Hi Lo

More information

Temperature Switches. General Instructions

Temperature Switches. General Instructions This instruction provides information for mounting, electrical connection, process connection, and calibration of SOR Temperature Switches. The SOR Inc. Temperature Switch consists of a pressure switch

More information

Palmer Circular Chart Recorders

Palmer Circular Chart Recorders Palmer Circular Chart Recorders Pressure & Temperature Recorders Designed for indoor or outdoor use, our recorders provide long service life, even in harsh conditions. Internal Assemblies, Clocks and Parts

More information

Mid-West Instrument. Diaphragm Type Differential Pressure Gauge & Switch Model 130. Shown here with Range 0-5 H2O

Mid-West Instrument. Diaphragm Type Differential Pressure Gauge & Switch Model 130. Shown here with Range 0-5 H2O Diaphragm Type Differential Pressure Gauge & Switch BULLETIN NO. 130/11 (SUPERSEDES BULLETIN NO. 130/02) is a rugged general purpose differential pressure gauge with a 4-1/2" round dial. Common Applications:

More information

Dual Hi-Lo Pressure Switches

Dual Hi-Lo Pressure Switches Dual Hi-Lo pressure switches are rugged, field-mounted instruments. The pressure sensing assemblies are conventional Static O Ring type. The main difference is that two sensing assemblies share a common

More information

37T Series Moisture Resistant Temperature Controls

37T Series Moisture Resistant Temperature Controls 37T Series Moisture Resistant Temperature Controls Moisture Resistant Temperature Control The 37T series of 3/4 (19mm) bimetal disc temperature controls from Therm-O-Disc offers proven reliability in a

More information

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4 to 1 NPT 4 Air and Inert Gas Intrinsically Safe Valves Brass, Aluminum, or Stainless Steel Bodies /4" to " NPT / 3/ 4/ 5/ 5/3 Features Intrinsically safe solenoid enclosures to provide corrosion resistance in harsh

More information

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 123

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 123 BULLETIN NO. 123/11 (SUPERSEDES BULLETIN NO. 123/03) Piston Type Differential Pressure Gauges Switches & Transmitters A low cost differential pressure gauge for use in measuring the pressure drop across

More information

Model 5000 Level Controller

Model 5000 Level Controller Features Multiple Configurations The 5000 level controller is easily configured for either reverse or direct actions for both pneumatic and electric pilot options. The pneumatic pilot is available in snap

More information

Electropneumatic Timing Relays Series 7000 Industrial

Electropneumatic Timing Relays Series 7000 Industrial DESIGN FEATURES Available in On-Delay, True Off-Delay, and On/Off-Delay. Timing from 0.1 seconds to 60 minutes, fully calibrated in linear increments. Oversize time-calibrated adjustment knobs, serrated

More information

Valve Position Monitors

Valve Position Monitors Valve Position Monitors EX Series for Hazardous Locations APL Series NEMA 4, 4X 1 LIMIT SWITCHES Triac APL Series Limit Switches The Triac APL Series Limit Switches feature high quality, easy to use multiple

More information

Heating Cable. Description

Heating Cable. Description Single Entry Power Connection Kit NEMA 4X Entry for 1 Cable 3/4 Conduit Hub Opening Lighted or Non-Lighted Multiple Entry Connection Box NEMA 4X Entry for up to 3 Cables Power, Splice or Tee Connection

More information

Ø 68 mm to ø 115 mm. Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating:

Ø 68 mm to ø 115 mm. Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: , EN 60079 Electrical Specifications Code: Incremental Resolution: Up to 10,000 ppr (pulses per revolution) Supply Voltage: ** 4.5 Vdc min. to 30 Vdc max. (45 ma max. - no load) Low: 500 mv max. at 10

More information

Mechanical Pressure Switches. Catalogue. Mechanical Pressure Switches. Control. Overview. every move

Mechanical Pressure Switches. Catalogue. Mechanical Pressure Switches. Control. Overview. every move Mechanical Pressure Switches Catalogue Mechanical Pressure Switches Overview Control every move Content Content Overview 4 Introduction 4 Metal Diaphragm 6 Bourdon Tube 7 Compact 8 Diaphragm Seal Piston

More information

NIFW % # ) Air and Inert Gas Non-Incendive Field Wiring Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

NIFW % # ) Air and Inert Gas Non-Incendive Field Wiring Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4 to 1 NPT Air and Inert Gas Non-Incendive Field Wiring Valves Brass, Aluminum, or Stainless Steel Bodies /" to " NPT / 5/ 5/3 Features solenoid enclosures to provide corrosion resistance in harsh environments Designed

More information

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures Mercmaster Series Luminaires LIGHTING: ENCLOSED AND GASKETED AREA /INDUCTION Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial, chemical

More information

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 124

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 124 BULLETIN NO. 124/12 (SUPERSEDES BULLETIN NO. 124/11) Mid-West Instrument Piston Type Differential Pressure Gauges Switches & Transmitters A low cost differential pressure gauge for use in measuring the

More information

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard. GE Measurement & Control UNIK 5800/5900 Flameproof/Explosion-Proof Pressure Sensing Platform The 5800 and 5900 are compact and rugged versions of the high performance UNIK 5000 pressure sensing platform

More information

Series P100AP and P100CP Encapsulated Pressure Control. Auto-reset Standard Duty. Feature and Benefits

Series P100AP and P100CP Encapsulated Pressure Control. Auto-reset Standard Duty. Feature and Benefits PSC9919 European Refrigeration Controls Catalogue Catalog Section 6 Product Bulletin P100 Series P100AP and P100CP Encapsulated Pressure Control. Auto-reset Standard Duty Introduction The P100 Series are

More information

GO gets it. The all in one proximity sensor and limit switch.

GO gets it. The all in one proximity sensor and limit switch. The all in one proximity sensor and limit switch. GO gets it. GO Switch is the most versatile sensing solution. It detects like a proximity switch and functions like a limit switch, providing higher reliability

More information

MA-5200 Series MA-5300 Series

MA-5200 Series MA-5300 Series MA-5200 Series MA-5300 Series Two-Position Actuators General Instructions Application The MA-5200 series and MA-5300 series actuators are used for two-position control of valves and dampers which require

More information

Model 5000 Level Controller

Model 5000 Level Controller Features Multiple Configurations The 5000 level controller is easily configured for either reverse or direct actions for both pneumatic and electric pilot options. The pneumatic pilot is available in snap

More information

M-100 Adjustable flow switch with right-angle flow

M-100 Adjustable flow switch with right-angle flow M-100 Adjustable flow switch with right-angle flow Operating Instructions and Quick Start Guide Table of Contents Introduction 03 Operation 03 Storage and Handling 03 Installation Instruction 03 Specification

More information

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device 2SGT Electronic Pressure Instrument Three Separate Functions in a Single Loop-Powered Device Switch Two Independent, Programmable SPST Solid State Relays Program switch open and close values in engineering

More information

Dual Hi-Lo Pressure Switches

Dual Hi-Lo Pressure Switches Form 217 Dual Hi-Lo pressure switches are rugged field mounted instruments. The pressure sensing assemblies are conventional Static O Ring type. The main difference is that two sensing assemblies share

More information

Heating Cable. Description

Heating Cable. Description 203312 Single Entry Connection Box NEMA 4X Entry for 1 Cable 3/4 Conduit Hub Opening Multiple Entry Connection Box NEMA 4X Entry for up to 3 Cables Power or Tee Connection 3/4 Conduit Hub Opening End Seal

More information

PRESSURE, VAcuum, DIFFERENTIAL PRESSURE,

PRESSURE, VAcuum, DIFFERENTIAL PRESSURE, 12 S er i es 12 Se r i e s PRESSURE, VAcuum, DIFFERENTIAL PRESSURE, AND TEMPERATURE SWITCHES PRESSURE, DIFFERENTIAL PRESSURE, AND TEMPERATURE SWITCHES DUAL SEAL CERTIFIED Features Compact 316 Stainless

More information

Type Type 1001 Transducers. I/P & E/P Transducers

Type Type 1001 Transducers. I/P & E/P Transducers Type 1001 I/P & E/P Description The Type 1001 is a patented family of electropneumatic instruments that is used to reduce a supply pressure to a regulated output pressure which is directly proportional

More information

Control Without Compromise. Suitable for use in hot, cold, wet, dirty, abusive, corrosive, and explosive environments

Control Without Compromise. Suitable for use in hot, cold, wet, dirty, abusive, corrosive, and explosive environments leverless limit switches Proximity Sensors for Harsh Environments and Tough Applications Suitable for use in hot, cold, wet, dirty, abusive, corrosive, and explosive environments Certified for use in all

More information

B Temperature Switches

B Temperature Switches B Temperature Switches General Instructions These instructions provide information for installation n and field calibration of B Temperature Switches. Process temperature changes cause proportional vapor

More information

U.S. GAUGE PMT PRODUCTS 820 PENNSYLVANIA BLVD., FEASTERVILLE, PENNSYLVANIA U.S.A. TEL: (215) FAX: (215)

U.S. GAUGE PMT PRODUCTS 820 PENNSYLVANIA BLVD., FEASTERVILLE, PENNSYLVANIA U.S.A. TEL: (215) FAX: (215) U.S. GAUGE PMT PRODUCTS 820 PENNSYLVANIA BLVD., FEASTERVILLE, PENNSYLVANIA 19053 U.S.A. TEL: (215) 355-6900 FAX: (215) 354-1801 www.ametekusg.com 2009, by AMETEK, Inc. All rights reserved. Printed in the

More information

MS Application. Features. Proportional Valve Actuator General Instructions

MS Application. Features. Proportional Valve Actuator General Instructions Proportional Valve Actuator Application The Proportional Valve Actuator is a non-spring return actuator used with proportional to 10 Vdc or 4 to 0 ma controllers and standard 1/" to 1-1/4" two-way and

More information

System 350 P352AB Electronic Pressure Control Series

System 350 P352AB Electronic Pressure Control Series System 350 P352AB Electronic Pressure Control Series System 350 Product Guide 930 Basic Controls Section Product/Technical Bulletin P352AB Issue Date 0200 The P352AB controls are On/Off electronic pressure

More information

MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES,

MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES, NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES, ENCLOSURE 6N FOR EXPLOSIVE ATMOSPHERES INSTALLATION AND OPERATION MANUAL PN 610-0014 E Manual No. 610-0014 Rev E Neo-Dyn 28150 Industry Drive

More information

Commercial Pressure and Float Switches for Power Circuits Catalog 9034CT9701R01/11 Class 9013, 9036, 9037, 9038

Commercial Pressure and Float Switches for Power Circuits Catalog 9034CT9701R01/11 Class 9013, 9036, 9037, 9038 Commercial Pressure and Float Switches for Power Circuits Catalog 9034CT9701R01/11 Class 9013, 9036, 9037, 9038 TM Table of Contents Table of Contents SELECTION GUIDE PUMPTROL COMMERCIAL PRESSURE SWITCHES...

More information

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering

More information

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators MAx-305 & MAx-38 Series MAx-405 Through MAx-49 Series Two-Position Actuators General Instructions Application For two-position operation of dampers, valves, and other equipment which require the return

More information

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions CP-90 CP-90 Electronic Drives General Instructions Application The CP-90 and CP-90 electronic actuator drives process a variable input signal from a controller to provide proportional control of an electric

More information

GO Switch Leverless Limit Switches 02 Reliable, Durable Position Sensing GO Switch leverless limit switches provide reliable, durable position sensing

GO Switch Leverless Limit Switches 02 Reliable, Durable Position Sensing GO Switch leverless limit switches provide reliable, durable position sensing GO Switch Leverless Limit Switches 02 Reliable, Durable Position Sensing GO Switch leverless limit switches provide reliable, durable position sensing in the most demanding plant conditions. Unlike mechanical

More information

Pressure Switch with Gauge for Pressure

Pressure Switch with Gauge for Pressure Pressure Switch with Gauge for Pressure General Specifications: Pressure Gauge Assembly for the medical gas alarm system shall incorporate a U.L. Listed single pole double throw snap-action micro switch.

More information

Commonwealth of Massachusetts Approved Product Approval code G

Commonwealth of Massachusetts Approved Product Approval code G AA...A4 Differential Air Pressure Switch Installation Instructions USA CDN Table of Contents Table of Contents...Page 1 Approvals...Page 1 Attention...Page 1 Specification...Page 2 Model Description &

More information

TC-200 Series. Application. Features. Applicable Literature. Single Bulb Thermostats General Instructions

TC-200 Series. Application. Features. Applicable Literature. Single Bulb Thermostats General Instructions T-200 Series Single ulb Thermostats General Instructions Application These units are used for on-off control of media temperature in ducts, tanks, etc. Features Mechanism enclosed in rugged die cast case

More information

The installation and maintenance of this product must be done under the supervision of an experienced

The installation and maintenance of this product must be done under the supervision of an experienced AA...A2 Differential Air Pressure Switch Installation Instructions USA CDN Table of Contents Table of Contents...Page 1 Approvals...Page 1 Attention...Page 1 Specification...Page 2 Model Description &

More information

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A Mid-West Instrument BULLETIN NO.ELEC IM121/10A Replaces IM121/09A INSPECTION Model 121 Indicating Differential Pressure Switch / Transmitter Electrical: Installation and Operating Instructions Upon receipt

More information

Core Industrial Products for Distributors and Wholesalers in North America

Core Industrial Products for Distributors and Wholesalers in North America Pressure and temperature monitoring and control, fluid control Core Industrial Products for Distributors and Wholesalers in North America 240 popular code numbers at your fingertips. www.danfoss.us/ia

More information

N2LED Series Emergency Luminaires Non-Metallic Emergency Egress Lighting Systems with Remote or Direct Mounted Lamps.

N2LED Series Emergency Luminaires Non-Metallic Emergency Egress Lighting Systems with Remote or Direct Mounted Lamps. Applications Enclosed and gasketed, non-metallic emergency lighting system suitable for use in areas where flammable gases or vapors may become present due to abnormal, unusual or accidental conditions

More information

M-50/55 Series. Fixed setting flow switch with in-line flow

M-50/55 Series. Fixed setting flow switch with in-line flow M-50/55 Series Fixed setting flow switch with in-line flow Features Very accurate custom flow settings For corrosive and non-corrosive liquids or gases All-Teflon switch available Senses increasing or

More information

Valves & Regulators. Pressure - Electronic Pressure Switches - Mechanical Pressure Switches - Pressure Transducer. Valves & Regulators

Valves & Regulators. Pressure - Electronic Pressure Switches - Mechanical Pressure Switches - Pressure Transducer. Valves & Regulators Valves & Regulators Pressure - Electronic Pressure Switches - Mechanical Pressure Switches - Pressure Transducer Valves & Regulators Temperature Level Flow Air Suspension Valves Barksdale - the total control

More information

Shuttle Type Switches For Moderate to High Liquid Flow Rates

Shuttle Type Switches For Moderate to High Liquid Flow Rates Shuttle Type Switches For Moderate to High Liquid Flow Rates Models for flow rate settings from.5 GPM to 100.0 GPM Rugged housings with port sizes ranging from 3/4 to 3 Efficient flow paths assure low

More information