1 Start Capacitor & Inrush, Facts & Myths Part 4 Now is the part where we get specific about Start capacitors and inrush. If you haven t read the first three parts please do so before reading this one or it may not make sense. I m going to come out and say it so you keep reading. What you were taught about hard start kits decreasing inrush amperage is wrong. Look at the oscilloscope image above. It s a 3 ton reciprocation compressor with equalized pressures and 230V applied. Now keep in mind the voltage value shown here is RMS and the amperage is PEAK so if the amps seem high in these charts that is why.
2 So this compressor starts up at locked rotor (on the run winding remember) and it gets up to speed at around 180 milliseconds of run time. That is pretty typical of a good, equalized compressor under normal conditions. Sometimes compressors do struggle to start and this can be due to. Low input voltage (usually due to voltage drop) Starting unequalized due to short cycling and or nonbleed (Hard Shut Off) expansion valves Long line lengths Refrigerant migration into the crankcase Compressor wear Here we show a system with low voltage applied (187v) and it HAS a hard start in place (not necessarily the same compressor as the last so don t try to compare apples to apples) In this case, the compressor doesn t get up to speed until
3 about 550 milliseconds and at that point both the run and start winding amperage drops. This proves that the hard start kit is working in that case. You can tell this because the only amperage that can enter the start winding is dictated by the run and start capacitors and like we said before the capacity of a capacitor is dictated completely by the capacitance (mfd) and the voltage across it. For the amperage of the start winding to go UP at 580 milliseconds, it can only be due to an increase in back EMF as that motor gets up to speed. Then at 600 milliseconds, the potential relay removes the start capacitor and the amperage drops down to the run capacitor only level. Conclusion #1 Fixing a voltage drop issue does more good than adding a hard start kit. A valuable test is measuring the voltage feeding your compressor with it under load and rectifying poor line voltage connections or undersized conductors.
4 Look at these two identical compressors, one with a hard start kit and one without. Techs are often taught that measuring inrush on the compressor common wire is a way to show how a hard start kit decreases startup amps. This isn t what we are measuring when we see a big difference in inrush amps. What we are measuring is how QUICKLY the compressor starts not the true inrush amps at start. I ve looked at the specs on several high-end ammeters that measure inrush and they read at
5 100 milliseconds. If you look at the two examples above the compressor with a hard start will read lower at 100 milliseconds because it is already almost at full speed and the LRA has nearly passed. LRA (locked rotor amps) is essentially the amperage the compressor runs when the run winding is functioning as a heater rather than a motor. The quicker the motor starts turning the quicker it gets out of the LRA range. Now consider the start winding. Take a look at the start winding with no hard start. it stays the same even though the compressor is essentially locked all the way up to 600 milliseconds. So even though the compressor is locked the current through the start winding is limited to what the run capacitor can hold and release. With the hard start in place, the start winding amperage peaks right up until the pote0 㔠ⴱ 爀椴til ⴱ 愀爀琩 ㄨright ⵧ 100 milliseconds.
6 Conclusion #3 Hard start kits don t decrease starting amps at the moment of start, they can t. What they can do is reduce the time it takes to get the motor started, So in a time-averaged sense, a hard start kit very well may reduce amperage and wattage. This is why a hard start is often specified for long line applications and non-bleed TXVs. It s also why Techs have found that adding a hard start can reduce light dimming complaints by speeding up the amount of time the compressor remains at LRA. Conclusion #4 Hard start kits do increase the current on the start winding, in fact, that s essentially all they do differently than a run capacitor. They both provide a phase shifted current to the start winding, a start capacitor just does MORE of it. The argument that hard start kits reduce wear and stress on the start winding is false. With no hard start the load on the start winding is constant and very low. Adding in a hard start adds in more current at start and the possibility of potential relay sticking that can definitely cause start winding stress. This isn t to say start kits are a problem when sized properly. They can and do reduce LRA on the run winding by adding more phase shifted current to start. Conclusion #5 Start capacitor sizing and potential relay voltage ratings are really important and should be selected to do the job of starting the compressor quickly without staying in too long or providing more start winding current than needed. Bryan
3 Phase Voltage Imbalance
3 Phase Voltage Imbalance Keep in mind when reading ANY article about electrical theory or application is that it only scratches the surface of the topic. You can dedicate years of your life to understanding
More informationWhy is the Breaker Tripping?
Why is the Breaker Tripping? Breakers are designed to trip anytime the circuit draws a current above the rating for a period of time. The time the breaker takes to trip is a function of how high the circuit
More informationThe Benefits of AC Hard Starts
The Right Choice SEALED UNIT PARTS CO., INC. PO Box 21, 2230 Landmark Place Allenwood, NJ 08720 USA 800-333-9125 www.supco.com The Benefits of AC Hard Starts From the Pioneer of Hard Start Technology THE
More informationBeware of Ghost Voltage
Beware of Ghost Voltage This article serves two purposes. First, it is an article for technicians who have heard of the dreaded ghost voltage but never understood why it happens. Second, for my own apprentices
More informationQuestions Section: Do you have questions that aren't covered? Please contact us!
Questions Section: 1. What are the screw terminals on the back of my XP600 for? 2. How do I hook up a remote turn-on switch for my XP250 / XP600 / XP1100/ MX series inverter? 3. Can I sell power back to
More informationAUT 125 ELECTRICAL II CH 54 & 55 CHARGING SYSTEMS
Name: Class: Date: AUT 125 ELECTRICAL II CH 54 & 55 CHARGING SYSTEMS Multiple Choice Identify the choice that best completes the statement or answers the question. 1. Technician A says that the diodes
More informationHard start kits help extend the life of compressors in
BY JAMES BOWMAN Images courtesy of RectorSeal Corp. This cover photo shows a 4-ton scroll compressor before and after a hard start kit was added. Inrush current was measured using the True RMS Inrush Current
More informationBASIC ELECTRICAL MEASUREMENTS By David Navone
BASIC ELECTRICAL MEASUREMENTS By David Navone Just about every component designed to operate in an automobile was designed to run on a nominal 12 volts. When this voltage, V, is applied across a resistance,
More informationTroubleshooting Guide for Limoss Systems
Troubleshooting Guide for Limoss Systems NOTE: Limoss is a manufacturer and importer of linear actuators (motors) hand controls, power supplies, and cables for motion furniture. They are quickly becoming
More informationSECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012
SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive
More informationHOW TO USE A MULTIMETER, PART 4: MEASURING CURRENT (AMPERAGE)
HOW TO USE A MULTIMETER, PART 4: MEASURING CURRENT (AMPERAGE) By: Rob Siegel First, we discussed how to use a multimeter for measuring voltage, or simply verifying that voltage is present. Last week, we
More informationFull file at
CHAPTER 2 FUNDAMENTALS OF ELECTRICITY Job Assignment for This Chapter: You are on a service call and a customer does not understand the basic theory of electricity and thinks you are trying to sell parts
More informationElectrical Testing in the Operating Room; Part 6
DOCTORDOCTOR It hurts when I shift! by Randall Schroeder Electrical Testing in the Operating Room; Part 6 IIn the operating room, doctors are faced with precise test procedures that are challenging and
More informationComments and facts below in chronological order as testing progress. Added non Added resistive Total load Watt meter kwh resistive
Comments and facts below in chronological order as testing progress Date Added non Added resistive Total load Watt meter kwh resistive from grid Jan 13 6 + 9 = 15 W 15 W 16 Jan 17 3 x 27 = 81 W 96 W 100
More informationHOW TO USE A MULTIMETER, PART 1: INTRODUCTION
HOW TO USE A MULTIMETER, PART 1: INTRODUCTION By: Rob Siegel First, thanks for all the comments, both here and on my Facebook page, about the piece on Electrical Safety two weeks ago. I felt that, if I
More informationALTERNATING CURRENT - PART 1
Reading 9 Ron Bertrand VK2DQ http://www.radioelectronicschool.com ALTERNATING CURRENT - PART 1 This is a very important topic. You may be thinking that when I speak of alternating current (AC), I am talking
More information14 Car Driving & Maintenance Myths
14 Car Driving & Maintenance Myths By Auto Parts Warehouse on February 4, 2015 There s always that one advice that your dad, brother or uncle imparted to you while you were learning how to drive. Whether
More informationTempest Tech-Tip 0813
August 2013 Tempest Tech-Tip 0813 Light My Fire Background Without a good spark, spark plugs can t get the job done well. How do you keep good sparks coming, so your spark plugs can light your fire with
More informationSW20 Coolant System Maintenance.
SW20 Coolant System Maintenance. This article contains information on how to change and bleed the coolant, as well as flushing the system. It is based on information in the service manual, tips gathered
More informationN1233 Series Troubleshooting Guide for N Alternator
N1233 Series Troubleshooting Guide for N1233-2 Alternator Hazard Definitions These terms are used to bring attention to presence of hazards of various risk levels or to important information concerning
More informationWorking Principle of Power Saver as per Manufacture:
Analysis the Truth behind Household Power Savers Introduction: A House hold power saving devices has recently received a lot of attention from both consumers and manufacturers. It is generally used in
More informationELECTRIC CURRENT. Name(s)
Name(s) ELECTRIC CURRT The primary purpose of this activity is to decide upon a model for electric current. As is the case for all scientific models, your electricity model should be able to explain observed
More informationTempest Tech-Tip 0613
June 2013 Tempest Tech-Tip 0613 Alaska Cold Starts Background What really happens in an oil filter during a cold start? First, by cold start, we re talking about starting an engine in temperatures below
More informationChapter 7: DC Motors and Transmissions. 7.1: Basic Definitions and Concepts
Chapter 7: DC Motors and Transmissions Electric motors are one of the most common types of actuators found in robotics. Using them effectively will allow your robot to take action based on the direction
More informationINVERTERS - GENERAL INFORMATION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER
INVERTERS - GENERAL INFORMATION Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER i INFO Please read White Paper "Characteristics of Sine Wave AC Power" for understanding electrical
More informationDYNAMIC DUO. Lab scopes and current
DYNAMIC DUO Combining the data acquisition capabilities of a lab scope with the versatility of a current probe gives you a powerful diagnostic tandem that s awfully hard to beat. BY MARK WARREN Lab scopes
More informationElectric Motor Controls BOMA Pre-Quiz
Electric Motor Controls BOMA Pre-Quiz Name: 1. How does a U.P.S. (uninterruptable power supply) work? A. AC rectified to DC batteries then inverted to AC B. Batteries generate DC power C. Generator, batteries,
More informationElectronic Refrigerator Diagnostics
Electronic Refrigerator Diagnostics IMPORTANT SAFETY NOTICE The information in this presentation is intended for use by individuals possessing adequate backgrounds of electrical, electronic, & mechanical
More informationElectrical Systems. Introduction
Electrical Systems Figure 1. Major Components of the Car s Electrical System Introduction Electricity is used in nearly all systems of the automobile (Figure 1). It is much easier to understand what electricity
More informationCOMPRESSOR TECHNICAL DATA
COMPRESSOR DEFINITION Designation F FI8,5HAK Nominal Voltage/Frequency 220240 V 5060 Hz Engineering Number 513200162 A APPLICATION / LIMIT WORKING CONDITIONS 1 Type 2 Refrigerant 3 Nominal voltage and
More informationMEANWELL DC/AC POWER INVERTERS
MEANWELL DC/AC POWER INVERTERS A301/A302-1K0 = 1000 Watts A301/A302-1K7 = 1500 Watts A301/A302-2K5 = 2500 Watts A301 = 12VDC input A302 = 24VDC input 230VAC output Don't disassemble Keep away from moisture
More informationCOMPRESSOR TECHNICAL DATA
COMPRESSOR DEFINITION Designation VES D9C Nominal Voltage/Frequency 230 V 400 Hz Engineering Number 513907002 A APPLICATION / LIMIT WORKING CONDITIONS 1 Type 2 Refrigerant 3 Nominal voltage and frequency
More informationQ&A FOR Webinar on Electrical Basics & Boiler Wiring
Q&A FOR Webinar on Electrical Basics & Boiler Wiring 4-20-16 Q: Is a dual fuel burner flame guard system more complicated than the one you showed us today? A: Not really. If the boiler is equipped for
More informationRoehrig Engineering, Inc.
Roehrig Engineering, Inc. Home Contact Us Roehrig News New Products Products Software Downloads Technical Info Forums What Is a Shock Dynamometer? by Paul Haney, Sept. 9, 2004 Racers are beginning to realize
More informationTroubleshooting Guide for Okin Systems
Troubleshooting Guide for Okin Systems More lift chair manufacturers use the Okin electronics system than any other system today, mainly because they re quiet running and usually very dependable. There
More informationfeature 10 the bimmer pub
feature 10 the bimmer pub BMW E90 Steering Angle Sensor Diagnosis A pattern failure may indeed point you to a bad component, but when the part is expensive you want to be very sure it s the culprit before
More informationSingle Phase Induction Motors
Single Phase Induction Motors Prof. T. H. Panchal Asst. Professor Department of Electrical Engineering Institute of Technology Nirma University, Ahmedabad Introduction As the name suggests, these motors
More informationLANCASTER HYDRO-FORCE
Bulletin # LHF4 10/14 LANCASTER HYDRO-FORCE 4 Submersible Motors Single Phase, 230 Volt, 60 Hertz 2-Wire Motors 3-Wire Motors Control Boxes for use with 3-Wire Motors TECHNICAL BULLETIN PAGE 1 INDEX Technical
More informationTroubleshooting Guide for N1225-1/N1237-1/N Alternators
Troubleshooting Guide for N1225-1/N1237-1/N1505-1 Alternators Hazard Definitions These terms are used to bring attention to presence of hazards of various risk levels or to important information concerning
More informationTuning A Walbro Carb. Walbro Carb TUNE UP & Illustrated Guide
Tuning A Walbro Carb Walbro Carb TUNE UP & Illustrated Guide by M. B. Fuess Walbro carbs aren t too difficult to tune up if you know what you re doing. First of all, you need to know how the carb works
More information10.0 Alternator Test
10.0 Alternator Test An alternator is the device used to produce the electricity the car needs to run and to keep the battery charged. The alternator uses the principle of electromagnetic induction to
More informationelabtronics Voltage Switch
elabtronics Voltage Switch Want to trigger a device when a monitored voltage, temperature or light intensity reaches a certain value? The elabtronics Voltage Switch is an incredibly easy way of doing it.
More informationOIL PRESSURE SAFETY CONTROLS
8-1095 Application Engineering Bulletin AE-1095-R9 Revised September 1, 1981 OIL PRESSURE SAFETY CONTROLS A major percentage of all compressor failures are caused by lack of proper lubrication. Improper
More informationMicro-Air Corporation Route 526 Allentown, NJ 08501
EasyStart 366 Commercial (board-only) Model ASY-366-X05 (36000 BTU, 3 ton) ASY-366-X06 (72000 BTU, 6 ton) Micro-Air Corporation www.microair.net 124 Route 526 help@microair.net Allentown, NJ 08501 Contents
More informationA/C Generator Systems
A/C Generator Systems What is the function of the charging system? Provide power for all electrical loads Recharge the starting battery What happens if the charging systems puts out too much power? Voltage
More informationPhysics Work with your neighbor. Ask me for help if you re stuck. Don t hesistate to compare notes with nearby groups.
Physics 9 2016-04-13 Work with your neighbor. Ask me for help if you re stuck. Don t hesistate to compare notes with nearby groups. Today we ll build on what we did Monday with batteries and light bulbs.
More informationC802/C802D/C802TD/C820 Alternators Troubleshooting Guide
C802/C802D/C802TD/C820 Alternators Troubleshooting Guide Hazard Definitions These terms are used to bring attention to presence of hazards of various risk levels or to important information concerning
More informationC.E. Niehoff & Co. N1601, N1602, N1603, and N1604 Alternator Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values
C.E. Niehoff & Co. N1601, N1602, N1603, and N1604 Alternator Troubleshooting Guide Hazard Definitions These terms are used to bring attention to presence of hazard(s) of various risk levels or to important
More informationDRIVING. Robotic Cars. Questions: Do you like to drive? Why? / Why not? Read the article below and then answer the questions.
Questions: Do you like to drive? Why? / Why not? Read the article below and then answer the questions. Robotic Cars The year is 2020, and it s 7:45 on a rainy Monday morning, and you are in your car and
More informationThe Mark Ortiz Automotive
August 2004 WELCOME Mark Ortiz Automotive is a chassis consulting service primarily serving oval track and road racers. This newsletter is a free service intended to benefit racers and enthusiasts by offering
More informationC627, C628, C631, C656, C657, C658, C671 and C680 Alternator Troubleshooting Guide
C627, C628, C631, C656, C657, C658, C671 and C680 Alternator Troubleshooting Guide Hazard Definitions These terms are used to bring attention to presence of hazards of various risk levels or to important
More informationMT/MTZ 50 Hz R22 R407C R134a R404A / R507
Selection & Application guidelines RECIPROCATING COMPRESSORS MT/MTZ Hz R22 R47C R134a R44A / R7 1 CYLINDER 2 CYLINDERS 4 CYLINDERS 8 CYLINDERS Refrigeration and Air Conditioning Expect more from us DANFOSS
More informationColeman Air C440-HVM 440 Amp Diversion Controller Version 3.2
Coleman Air C440-HVM 440 Amp Diversion Controller Version 3.2 With Extended Diversion Mode Page 1 Page 2 Introduction This diversion controller is the result of our many attempts to use the controllers
More informationAsynchronous Restriking CDI 2 channel
Asynchronous Restriking CDI 2 channel Parts List ARC-2 module Decals Power Cable Fuse Specifications Operating Voltage: 8-20V Operating Current: Max Operating RPM: Ambient Temp range: Ignition inputs:
More informationName Date Period. MATERIALS: Light bulb Battery Wires (2) Light socket Switch Penny
Name Date Period Lab: Electricity and Circuits CHAPTER 34: CURRENT ELECTRICITY BACKGROUND: Just as water is the flow of H 2 O molecules, electric current is the flow of charged particles. In circuits of
More informationWhy and how to adjust a TXV / TEV
Why and how to adjust a TXV / TEV As we talked about in an earlier podcast, a TXV is designed to maintain a specified and constant superheat at the outlet of the evaporator coil. It does this through a
More informationHow Off Grid Solar Works
How Off Grid Solar Works The Sun (Fuel Source) With a solar power system you never need to purchase the fuel; the fuel is wirelessly transmitted from a fusion reactor that is safely placed 149.6 million
More information14 Single- Phase A.C. Motors I
Lectures 14-15, Page 1 14 Single- Phase A.C. Motors I There exists a very large market for single-phase, fractional horsepower motors (up to about 1 kw) particularly for domestic use. Like many large volume
More informationWiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents.
1 10/2014 REV 7 !!Attention!! Before performing diagnostics: Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents. Check for Fault Codes using the
More information11.1 CURRENT ELECTRICITY. Electrochemical Cells (the energy source) pg Wet Cell. Dry Cell. Positive. Terminal. Negative.
Date: SNC1D: Electricity 11.1 CURRENT ELECTRICITY Define: CIRCUIT: path that electrons follow. CURRENT ELECTRICITY: continuous flow of electrons in a circuit LOAD: device that converts electrical energy
More informationTRACKING BLADES WITH THE ENSTROM ROTOR SYSTEM ENSTROM TH-28/480 SERIES MAINTENANCE TRAINING
TRACKING BLADES WITH THE ENSTROM ROTOR SYSTEM 1 Experience tells us that some of the earlier published information on how to track the Rotor system isn t really optimum. This procedure should be used anytime
More informationCOMPRESSOR TECHNICAL DATA
COMPRESSOR DEFINITION Designation VEM Z4H Nominal Voltage/Frequency 230 V 400 Hz Engineering Number 513902027 A APPLICATION / LIMIT WORKING CONDITIONS 1 Type 2 Refrigerant 3 Nominal voltage and frequency
More informationTHE MOTOR/GENERATOR OF ROBERT ADAMS
THE MOTOR/GENERATOR OF ROBERT ADAMS WHEN HE WAS 70 YEARS OLD, ROBERT ADAMS OF NEW ZEALAND DESIGNED A VERY EFFECTIVE MOTOR/GENERATOR. HE WAS TOLD TO DESTROY HIS DEVICE OR HE WOULD BE KILLED. ROBERT DECIDED
More informationTrucking Info: Equipment 7 Factors to Consider When Installing an Inverter
Trucking Info: Equipment 7 Factors to Consider When Installing an Inverter From what size to get to company policies, what fleets need to know when choosing and installing a power inverter. September 2013,
More informationIn the last two issues of GEARS, we
Diagnosing Pressure Control Circuits Part 3 of a 3-Part Series by Steve Bodofsky In the last two issues of GEARS, we looked at how solenoids can be used to control pressures. We examined the signals that
More informationFord Scorpio 95+ Charging System
Functional Overview of the Ford Scorpio 95+ Charging System Introduction All models of Ford Scorpio 95+, utilise an and charging system. The alternator is spun around by the engine, this provides electrical
More informationC.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values
C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide Hazard Definitions These terms are used to bring attention to presence of hazards of various risk levels or to important information
More informationHow to build an energy generator with an old oil barrel without oil (Savonius wind generator)
How to build an energy generator with an old oil barrel without oil (Savonius wind generator) Index 1. Introduction... 1 2. Some words about the wind energy in general... 2 2.1 Mister Betz and the energy
More informationClear View II. Simple Window Defrosting. Defroster Product Guide. Over 200 new sizes in 12 and 24 volt! Frost Fighter. Now 40% warmer. New!
New! Frost Fighter Clear View II Defroster installation and replacement made easy Simple Window Defrosting Defroster Over 200 new sizes in 12 and 24 volt! FROST FIGHTER Easy to install defrosters and controls
More informationNISSAN FIGARO TURBO PROBLEMS
NISSAN FIGARO TURBO PROBLEMS The installation of a turbocharger is a relatively easy way of increasing the power of an engine it s an alternative to increasing the size and weight of an engine. On the
More informationChapter 4 Utility Systems Electrical
Chapter 4 Utility Systems Electrical Utility Systems Electrical The electrical supply to your home begins outside, where you will see either an overhead feed and piping down the side of your home or (if
More informationMODEL 2001 HERMETI-CHECK OPERATING INSTRUCTIONS
MODEL 2001 HERMETI-CHECK OPERATING INSTRUCTIONS Model 2001 HERMETI-CHECK tests all single phase compressors up to 5 HP, 110, 220, or 277 volts. The HERMETI-CHECK comes equipped with a built in 200 micro
More informationElectronic Paint- Thickness Gauges What They Are, and Why You Need Them
By Kevin Farrell Electronic Paint- Thickness Gauges What They Are, and Why You Need Them Measuring the paint in microns. The reading of 125 microns is a fairly normal factory reading. This shows that the
More informationMulti-colour LED Status Light - using it as a diagnostic tool:
All J+J electric actuators are tested prior to shipping. Most issues are site related, we hope that you will find a solution to your problem in this guide. If not, please contact us for support. Multi-colour
More informationAdapted from presentation developed by Scott Fausneaucht
Adapted from presentation developed by Scott Fausneaucht Definition of Electricity Electrical Fundamentals Generation & Transmission Transformers Fuses & Circuit Breakers Motors Motor Controls Safety Not
More informationTONY S TECH REPORT. Basic Training
TONY S TECH REPORT (Great Articles! Collect Them All! Trade them with your friends!) Basic Training OK YOU MAGGOTS!! Line up, shut up, and listen good. I don t want any of you gettin killed because you
More informationWelcome to the SEI presentation on the basics of electricity
Welcome to the SEI presentation on the basics of electricity 1 Electricity is a secondary energy source, meaning that it is produced from other, primary, energy sources. There are several primary sources
More informationELECTRICAL INTERFACE TO DC BRUSHLESS MOTORS SUPPLIED IN TECNADYNE THRUSTERS, LINEAR & ROTARY ACTUATORS & HPU s
Tecnadyne Application Note AN605 5/12/2006 Page 1 of 5 ELECTRICAL INTERFACE TO DC BRUSHLESS MOTORS SUPPLIED IN TECNADYNE THRUSTERS, LINEAR & ROTARY ACTUATORS & HPU s 1. Introduction The electrical interface
More informationWhy do the dots go where they do?
Reprinted from Real Answers Why do the dots go where they do? Volume 13, Issue 1 trucktires.com 1-800-543-7522 ask the DOCTOR Bridgestone tires have either a red or yellow dot, which can be used to mount
More informationAn Actual Driving Lesson. Learning to drive a manual car
An Actual Driving Lesson Learning to drive a manual car Where are the controls that I might have to use in my driving: Knowing where the controls are, and being able to locate and use them without looking
More information600 Series Troubleshooting Guide for C651 and C654 Alternators
600 Series Troubleshooting Guide for C651 and C654 Alternators Hazard Definitions These terms are used to bring attention to presence of hazards of various risk levels or to important information concerning
More informationMotor Protection. Voltage Unbalance & Single-Phasing
For Summary of Suggestions to Protect Three-Phase Motors Against Single-Phasing see the end of this section, page 137. Historically, the causes of motor failure can be attributed to: Overloads 30% Contaminants
More informationIs Your Factory Power Source Corrupting Your Product Testing? September 2015 Author: Steve Boegle Engineering Group Leader, Behlman Electronics
Is Your Factory Power Source Corrupting Your Product Testing? September 2015 Author: Steve Boegle Engineering Group Leader, Behlman Electronics Synopsis: This paper describes the use of AC power supplies
More informationThe Life of a Lifter, Part 2
Basics Series: The Life of a Lifter, Part 2 -Greg McConiga Last time we looked at some complicated dynamics and compared flats to rollers. Now for the hands-on. 6 FEATURE This off-the-shelf hydraulic lifter
More informationElectrical Safety For Everyone. Leader s Guide
4609 Electrical Safety For Everyone Leader s Guide ELECTRICAL SAFETY FOR EVERYONE This easy-to-use Leader s Guide is provided to assist in conducting a successful presentation. Featured are: INTRODUCTION:
More informationCHARGING SYSTEM 8C - 1 CHARGING SYSTEM CONTENTS
ZG CHARGING SYSTEM 8C - 1 CHARGING SYSTEM CONTENTS page GENERAL INFORMATION OVERVIEW... 1 DESCRIPTION AND OPERATION BATTERY TEMPERATURE SENSOR... 2 CHARGING SYSTEM OPERATION... 1 ELECTRONIC VOLTAGE REGULATOR...
More informationCOMPRESSOR TECHNICAL DATA
COMPRESSOR DEFINITION Designation F FI10HAK Nominal Voltage/Frequency 220230 V 5060 Hz Engineering Number 513200288 A APPLICATION / LIMIT WORKING CONDITIONS 1 Type 2 Refrigerant 3 Nominal voltage and frequency
More informationCustomer Installation Standards for Electric Service 2013 Edition. Frequently Asked Questions February 1, 2013
Customer Installation Standards for Electric Service 2013 Edition Frequently Asked Questions February 1, 2013 The 2008 edition of the Customer Installation Standards for Electric Service has been revised
More informationVariable Speed Pumping
Variable Speed Pumping Jim Vukich Application Engineer ITT Corp. Malvern, PA Why Do It? Why Do It? Flow-Matching Minimize Starting & Stopping Flexibility Different Discharge Points, Flows Changing Conditions
More informationCSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date:
CSDA Best Practice Title: Hi-Cycle Concrete Cutting Equipment Issue No: CSDA-BP-010 : Oct 1, 2010 Revised : Introduction Hi-cycle/high frequency concrete cutting equipment has become more prevalent in
More informationADVANCED PID TROUBLESHOOTING
ADVANCED PID TROUBLESHOOTING August 29, 2016 A KEY POINT If the drive is telling you something via a Fault, then the problem is probably not the drive. The drive is recognizing a fault and telling you
More informationSolar Power. Questions Answered. Richard A Stubbs. Richard A Stubbs 2003, distribution permitted see text for details
Solar Power Questions Answered Richard A Stubbs Richard A Stubbs 2003, 2008 distribution permitted see text for details Brought to you by: SunrayPowerSystems.com 1 Contents Introduction... 3 Disclaimer...
More informationInstallation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor
World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com
More informationSelected excerpts from the book: Lab Scopes: Introductory & Advanced. Steven McAfee
Selected excerpts from the book: Lab Scopes: Introductory & Advanced Steven McAfee 1. 2. 3. 4. 5. 6. Excerpt from Chapter 1 Lab Scopes How do they work? (page 6) Excerpt from Chapter 3 Pattern Recognition
More informationCHASSIS TECH TIPS. Subject: VOLTAGE DROP TEST
Subject: VOLTAGE DROP TEST 1. RELEVANT MODELS: All Hino Models (Cab over and Conventional) 2. COMPLAINT: Electrical failure 3. CAUSE/CONDITION: High resistance and poor connections 4. CORRECTION: Proper
More informationSeries circuits. The ammeter
Series circuits D o you remember how the parts of the torch on pages 272 3 were connected together? The circuit contained several components, connected one after the other. Conductors, like the metal strip
More informationDisco 3 Clock Spring / Rotary Coupler replacement
Disco 3 Clock Spring / Rotary Coupler replacement I recently had to change my Clock spring and thought some folks may find it helpful to see what it entailed. I did lots of reading around but couldn t
More informationParking and Reversing Safely
GE Capital Safe Driving Parking and Reversing Safely Driver guide Information Factsheet Safe Driving Parking in Car Parks Avoiding costly damage Many of us struggle with parking in car parks long after
More informationMeasurement and Analysis of the Operation of a Single-Phase Induction Motor
Measurement and Analysis of the Operation of a Single-Phase Induction Motor In class I have shown you the carcass of a four-pole, single phase, ¼ HP motor in varying stages of disassembly. In this lab,
More informationActual CFM = VE Theoretical CFM
Here is a brief discussion of turbo sizing for a 2.0 liter engine, for example, the 3-SGTE found in the 91-95 Toyota MR2 Turbo. This discussion will compare some compressor maps from the two main suppliers
More information