STAND MODEL FOR MACH M2

Size: px
Start display at page:

Download "STAND MODEL FOR MACH M2"

Transcription

1 Mounting instructions Directions for use STAND MODEL FOR MACH M2 Stand lamps: Mach M2... Mach M2 F... Order No Order No GmbH u. Co. KG, Flossmannstrasse 28, D Ebersberg Tel.: +49 (0) , Fax +49 (0) Internet: Edition / Bak Page 1/19

2 List of contents 1. Safety instructions... Page 3 2. Installation summary stand lamps... Page 4 3. Mounting instructions... Page Mounting the stand... Page Mounting the stand foot... Page Mounting the stand tube to the stand foot... Page Mounting the spring arm and the lamp head... Page Mounting the spring arm to the stand tube... Page Mounting the lamp head to the spring arm... Page Installation of the stand... Page Cleaning... Page Maintenance... Page Periodical maintenance work... Page Adjusting the spring force... Page Maintenance of the securing segment... Page Data... Page Technical data... Page Environmental conditions... Page Disposal... Page CE- mark... Page Dimensions and range of movement... Page Spare parts... Page Spare parts list... Page 16 Appendix to the mounting instructions Page Edition / Bak Page 2/19

3 1. Safety instructions The stand foot must not be connected to the mains, until it has been fully assembled and installed. Connect the stand only to a correctly installed socket with earthing contact. The socket used must be installed according to the requirements of IEC and VDE This device is not suitable for use in hazardous locations. The devices are not suitable for use in combustible blends of anaesthesia agents with oxygen or nitrous oxide. Repairs to the stand and special installation work on the sliding contacts should only be carried out by ourselves or a company expressly authorised by ourselves. The manufacturer is only responsible for operational safety of the stand foot when repairs and modifications are carried out by his own staff or by persons who guarantee compliance with the safety regulations. The manufacturer is not responsible for damage to persons or property caused by incorrect or improper use, or when used for incorrect purposes. General information These installation instructions must be kept at hand together with the relevant operating instructions for consultation at any time. The stand is designed for carrying and positioning of medical examination lamps up to a max. weight of 4,5-5kg and to supply the lamps with electricity. The stand is available: with built-in transformer 22,8V sec.; 50/60Hz The output voltage of the transformer is not adjustable. The device is designed for continuous operation. Make sure, that the maximum load does not exceed 5kg. Please read these mounting instructions and directions for use carefully before working with the device. In this way you will profit from all advantages of the device and save yourself and other persons from harm Edition / Bak Page 3/19

4 2. Installation summary stand lamps Mach M2 / Mach M2 F 1 The stand has a built-in transformer 230V / 22,8V 50/60Hz and is delivered in combination with the lamp Mach M2 / Mach M2 F. The transformer is positioned in a transformer housing 1 on the stand base Edition / Bak Page 4/19

5 3. Mounting instructions 3.1 Mounting the stand 1 Extent of supply for stand foot: 1 stand foot 1 stand tube 1 spring arm 2 3 Mounting accessories: 2 antistatic rollers with brakes 2 rollers without brakes 1 colour foil 2 plastic half-rings 1 plastic bushing 1 security segment 1 washer 1 retaining ring 1 pliers for retaining ring Mounting the stand foot To mount the stand foot proceed as follows: Guide the two antistatic rollers 1 with brakes through the ring terminal of the potential compensation line 2 and insert the two rollers completely into the stand foot 3. Insert the rollers without brakes completely into the stand foot. Check if the rollers are firmly fixed. Pull off the adhesive foil 4, lay colour foil into the eye-shaped depression of the stand foot and press evenly to surface. Pull off protective foil Edition / Bak Page 5/19

6 3.1.2 Mounting the stand tube to the stand foot CAUTION! Damage to the equipment: If the nose fastening is not inserted properly, and then the stand tube has not been bolted, the mobile stand can fall. Engage the nose fastening and tighten the wing-bolt M8 x 40mm with a spring washer. Unscrew the winged screw with the spring washer 1 from the stand tube 2. Insert the stand tube 2 in such a way that the recess in the tube 3 is seated in the nose of the stand base 4 and cannot be rotated any more. Check for secure seating. Screw in the winged screw with the spring washer 1 and tighten it. The stand tube is delivered with premounted toroidal transformer. You can find the instructions for adjusting the cover at the stand and for changing the fuses beginning with page 17 (appendix to the mounting instructions) Edition / Bak Page 6/19

7 3.2 Mounting the spring arm and the lamp head Mounting the spring arm to the stand tube For mounting the spring arm proceed as follows: Unscrew recessed head screw 1, pull off cover cap 2 and remove it by pulling it upward. Insert spring arm journal, place washer 4 and secure the spring arm with retaining ring 5. Check if the retaining ring 5 is firmly fixed. Caution: If not handled properly the retaining ring 5 gets loose and the spring arm falls off the connection. Always mount washer 4. Close electrical connection 6. Replace cover cap 2 and fix it with recessed head screw Edition / Bak Page 7/19

8 3.2.2 Mounting the lamp head to the spring arm ATTENTION! Notice the rated voltage information! Coupling journal Lamp bow Sticker with voltage information Each lamp has a red sticker applied near the coupling journal at the lamp bow. The sticker shows the rated voltage of the lamp. Connect the lamp only to the prescribed voltage, to avoid irreparable damage (e.g. the electrical components). Following rated voltage is usual: 22,8 V After mounting the lamp take off the sticker and dispose it, otherwise it could fall down in the OT-field after some time! Attention: If the spring arm is pushed downwards (the arm is under spring tension) it may bounce up and cause harm. While mounting the lamp head no other persons are allowed to be within the swivel range of the spring arm. Note: Maximum permissible load of spring arm: 4,5 5 kg! Edition / Bak Page 8/19

9 Do not remove screw 13, it is designed to fix the sliding contact and provides earthling! Attention: If the spring arm is pushed downwards (the arm is under spring tension) it may bounce up and cause harm. While mounting the lamp head no other persons are allowed to be within the swivel range of the spring arm Mounting the lamp Mach M2 / M2F to the spring arm Loosen brake screw 1, so the plastic bushing 2 can be slipped easy onto the spring arm. Slip plastic bushing 2 onto the spring arm to overlap slots 3. Check if the journal 4 of the lamp is greased. Insert the greased journal 4 of the lamp and insert security segment 5 completely into slot 3, that the security segment leads in groove 6. Rotate plastic bushing 2 by 180 up to the provided drilling for the brake screw and screw in brake screw 1 until you reach the desired brake effect for lamp head 4. Check if lamp head 4 is firmly fixed ATTENTION! It is absolutely necessary to mount this securing segment! Edition / Bak Page 9/19

10 3.3 Installation of the stand 1. Take the stand to the working place and arrest the two rollers with brakes. Caution: Do not touch damaged electrical parts. Danger of electrical shock! If you notice a damaged mains cable or plug do not plug in. Call your service number and report the damage. 2. Check if mains plug or mains cable are damaged. 3. Please check that an earthed socket is available within the working area of the lamp. The socket to be used for the lamp must be installed according to the requirements stipulated by the IEC or VDE Remark: Do not overrun any objects on the floor or the mains cable. The stand might tip over. 4. Cleaning Note: Before doing any cleaning work turn off the lamp, draw plug from mains and make sure that the lamp cannot be switched on again. Please ensure, that no disinfection liquid flows into the joints or lamp head. The surface of the stand can be easily kept clean by simply wiping with a wet cloth. You can use conventional cleaning agents. Caution: In order to prevent any damage at plastic parts do not use scouring agents or alkaline, acidic and alcoholic cleaning agents. For cleaning proceed as follows: Draw plug from mains. Wipe the surface of the stand with a wet cloth. As a cleaning agent you can use water or a soap solution (washing-up liquid). 5. Maintenance Note: Before doing any maintenance work, turn off the lamp, draw plug from mains and make sure, that the lamp cannot be switched on again. 5.1 Periodical maintenance work The following maintenance work / tests has / have to be done every six months: check on defects in paint work; check on fissures at plastic parts; check on deformation of the suspension. The following maintenance work / tests has / have to be done once a year: check the function; electrical safety test; check the suspension; Edition / Bak Page 10/19

11 Remark: Check the fixing screw at the lower part of the stand once a year and, if necessary, adjust. Check and grease the security segment once a year. 5.2 Adjusting the spring force Springs are wearing parts, thus the spring force can decrease in time and must be readjusted. Note: Set the spring force in such a way, that the spring arm with the lamp head holds its position at every set height. Take out screw (1) and remove cover (2) (Fig.1). Move the spring arm to a position where the crossdrilled nut (3) is visible through one of the two slots (4) (Fig.2). Take the pin (5) from the accessories and insert it into one of the holes on the circumference of the nut such that it can be turned into the desired direction (Fig.3). If the spring arm drops: The spring force is too low. - The adjustment nut (3) must be rotated to the right (clockwise facing the rear joint) (Fig.3). If the spring arm rises: The spring force is too high: - The adjustment nut (3) must be rotated to the left (counterclockwise - facing the rear joint) (Fig.4) Edition / Bak Page 11/19

12 5.3 Maintenance of the securing segment Dismount the lamp head in reverse order of mounting (see chapter 3.2.2). Check the thickness of the segment. It must be at least 1,5mm. In case the thickness of the segment is less than 1,5mm it has to be changed. Grease the segment and the coupling journal of the lamp. Mount the lamp to the spring arm, as described in chapter Data 6.1 Technical data Electrical Data Rated voltage depending on model Maximum power depending on model Nominal frequency 100 V / 120 V / 230 V 60 W / 90 W 50 / 60 Hz Fuses 5 x 20 mm, time-lag T Rated voltage prim. Rated power of the transformer Fuse rating 120 V 60 VA 1,0 A 230 V 60 VA 0,5 A 100 V to 127 V 60 VA 1,25 A 213 V to 247 V 60 VA 0,63 A 120 V 90 VA 1,6 A 230V 90 VA 0,8 A The device is not suitable for use in combustible blends of anaesthesia agents with air or for use in combustible blends of anaesthesia agents with oxygen or nitrous oxide. The device is designed for continuous operation Edition / Bak Page 12/19

13 6.2 Environmental conditions Operation Min. Max. Temperature +10 C +40 C Relative athmospheric humidity 30% 75% Air pressure 700hPa 1060hPa Transport / storage Min. Max. Temperature +10 C +40 C Relative athmospheric humidity 30% 75% Air pressure 700hPa 1060hPa 7. Disposal The stands do not contain any danger goods. The components of the stand should be properly disposed at the end of its shelf life. In order to respect all regulations for disposal, please contact us before disposing the product. 8. CE- mark The stands comply to the standards 93/42/EEC for medical products of the European Community s Council. applies the standard EN GmbH is certified according to DIN EN 46001:1996 and DIN EN ISO 13485: Edition / Bak Page 13/19

14 9. Dimensions and range of movement Edition / Bak Page 14/19

15 10. Spare parts 01 21,22 04 Mach M Edition / Bak Page 15/19

16 Spare parts - continuation 29, Spare parts list 26 Item Qty. Name EDVNO Remarks 01 1 Decorative foil Securing sleeve Ondal Securing segment Brake screw Screw M3x4 DIN 966:Ni for cover Cover Lateral cover, left Stopper Handle half Four-foot base with weighting plate Roller Roller with brake Connecting cable with plug Transformer 230V/24V 80W Spring arm for stand 3,2 kg Screw M3x10 D7985:Zn Lock washer A3, Stand tube with transformer, complete 25 1 Cover for toroidal transf., consisting of: Ondal Cover, 1 piece - Clamp ring, 1 piece - PT-screw M3x4, 1 piece 26 1 Transfomer base, complete, consisting of: Ondal Base with 2 clamps, 1 piece - Base, 1 piece - Clip, 2 pieces - PT-screw M4x30, 2 pieces 27 1 Toroidal transformer 90W Support plate for transformer, Ø90xØ50x1,5 Ondal Fuses 5 x 20 mm, 0,8A time lag T 230V 30 2 Fuses 5 x 20 mm, 1,6A time lag T 120V Edition / Bak Page 16/19

17 Appendix to the mounting instructions Acrobat-Swing mobile stand for Mach M2 (Mobile stand with pre-mounted toroidal transformer) 1. Mounting of the additional weight and mounting of the half rings are not applicable. 2. To adjust the cover to the base Turn the cover clockwise Edition / Bak Page 17/19

18 Tighten the 2 fixing screws M4x8. Fixing screws 3. Changing the fuses To protect the transformer and the end device, the fuses are installed. WARNING! ELECTRICAL SHOCK For all maintenance work, switch off the equipment, pull out the main plug and secure it form being switched on again. The technical specification for the fuses can be found on the back side of this document and on the label inside the cover. CAUTION! Damage to the equipment Apply only the specified fuses. Change the fuses corresponding to the following steps: 1. Open the cover Loosen the screw, but do not unscrew it completely Edition / Bak Page 18/19

19 Push up clamp ring and cover and secure them. 2. Changing the fuses Change the broken fuse. 3. Close the cover Push up clamp ring and cover downwards. Tighten the screw Edition / Bak Page 19/19

ACROBAT SWING STAND MODEL

ACROBAT SWING STAND MODEL Mounting instructions Directions for use ACROBAT SWING STAND MODEL Stand lamps: Mach 120... Mach 120F... Mach 130... Mach 130F... Mach LED 120... Mach LED 120F... Mach LED 130... Mach LED 130F... Order

More information

ACROBAT SWING STAND MODEL

ACROBAT SWING STAND MODEL Mounting instructions Directions for use ACROBAT SWING STAND MODEL Dr. Mach GmbH u. Co.KG, Flossmannstrasse 28, D-85560 Ebersberg Tel.: +49 (0)8092 2093 0, Fax +49 (0)8092 2093 50 Internet: www.dr-mach.com,

More information

CEILING ATTACHMENT FOR MACH M2

CEILING ATTACHMENT FOR MACH M2 Mounting instructions Directions for use CEILING ATTACHMENT FOR MACH M2 Ceiling lamps: Mach M2... Mach M2 F... Order No. 170 120 3330 Order No. 170 230 3330 GmbH u. Co., Flossmannstrasse 28, D-85560 Ebersberg

More information

CEILING ATTACHMENT ACROBAT SWING

CEILING ATTACHMENT ACROBAT SWING Mounting instructions Directions for use CEILING ATTACHMENT ACROBAT SWING Dr. Mach GmbH u. Co.KG, Flossmannstrasse 28, D-85560 Ebersberg Tel.: +49 (0)8092 2093 0, Fax +49 (0)8092 2093 50 Internet: HUwww.dr-mach.com

More information

STAND FOOT - STAND TUBE

STAND FOOT - STAND TUBE Mounting instructions Directions for use STAND FOOT - STAND TUBE Stand lamps: Mach 130 / Mach 130F Soloflex Triaflex / Triaflex R96 Trigenflex / Trigenflex R96 GmbH u. Co., Flossmannstrasse 28, D-85560

More information

Mounting instructions Directions for use MAKROLUX. Halogen-spot lamp for consulting room and hospital

Mounting instructions Directions for use MAKROLUX. Halogen-spot lamp for consulting room and hospital Mounting instructions Directions for use MAKROLUX Halogen-spot lamp for consulting room and hospital Stand model with five-feet base, design without heat protection filter 1100 1012 00 Stand model with

More information

Dr. Mach Lamps and Engineering

Dr. Mach Lamps and Engineering Mounting instructions MACH LED 3MC/SC STAND MODEL Mach LED 3MC stand lamp Order No. 370 530 1200 Mach LED 3SC stand lamp Order No. 360 530 1200 Accessories Surcharge for integrated laser pointer Order

More information

Dr. Mach Lamps and Engineering

Dr. Mach Lamps and Engineering Directions for use SOLOFLEX Stand lamp one-handed height adjustment Order No. 1281 3011 00 Stand lamp - swivel arm Order No. 1281 3012 00 Wall lamp Order No. 1281 3021 00 Ceiling lamp for room heights

More information

Dr. Mach Lamps and Engineering

Dr. Mach Lamps and Engineering MOUNTING INSTRUCTIONS Ceiling attachment Wall attachment Applies to: Soloflex Triaflex Trigenflex Quintaflex Mach 120 Mach 130 Mach M3 Mach M5 Mach 380 Mach 400 Mach 500 Tool and instrument trays GmbH

More information

Dr. Mach Lamps and Engineering

Dr. Mach Lamps and Engineering DIRECTIONS FOR USE Triaflex Stand lamp Order No. 3001 1012 00 Wall lamp Order No. 3001 1021 00 Single ceiling lamp Order No. 3001 1031 25 Order No. 3001 1031 30 Ceiling lamps combinations Emergency power

More information

Dr. Mach Lamps and Engineering

Dr. Mach Lamps and Engineering MOUNTING INSTRUCTIONS Ceiling attachment Wall attachment Applies to: Soloflex Triaflex Trigenflex Quintaflex Mach 120 Mach 130 Mach M3 Mach M5 Mach 380 Mach 400 Mach 500 Tool and instrument trays GmbH

More information

Dr. Mach Lamps and Engineering

Dr. Mach Lamps and Engineering Mounting instructions Directions for use EMERGENCY POWER LAMP Triaflex / Triaflex R96 emergency power lamp Trigenflex / Trigenflex R96 emergency power lamp Mach M3 F- / DF- / F/H- / DF/H emergency power

More information

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN Electropneumatic Converters i/p Converters Type 6111 Fig. 1 Type 6111 in standard version Fig. Type 6111 mounted on a supply air manifold Fig. 3 Type 6111 in field enclosure Mounting and Operating Instructions

More information

D-LUX DENTAL LIGHT INSTALLATION AND OPERATION INSTRUCTIONS. Model AL-711M Model AL-712M Model AL-715M

D-LUX DENTAL LIGHT INSTALLATION AND OPERATION INSTRUCTIONS. Model AL-711M Model AL-712M Model AL-715M DENTAL LIGHT D-LUX TM Model AL-711M Model AL-712M Model AL-715M INSTALLATION AND OPERATION INSTRUCTIONS IMPORTANT After installation is completed, check all the bolts, screws and fasteners to confirm that

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS Emergency Cord Switch Type LRS 004 Device identification no.: 93.046 690.004 OPERATING INSTRUCTIONS 2 CE-Sign and Conformity The device meets the requirements of the valid European and national regulations.

More information

IU0U automatic charger Read these instructions carefully before the installation and commissioning and keep them in a safe place. Pass it on to the buyer in case of the further sale of the system. Contents

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS Conveyor Belt Misalignment Switch Type MRS 001 Device Identification No.: 91.055 301.001 OPERATING INSTRUCTIONS 2 CE-Sign and Conformity The device meets the requirements of the valid European and national

More information

Installation Guide VHM Wall Mount Kit for Philips MX600/700/800 and MP60/70 IntelliVue

Installation Guide VHM Wall Mount Kit for Philips MX600/700/800 and MP60/70 IntelliVue Installation Guide VHM Wall Mount Kit for Philips MX600/700/800 and MP60/70 IntelliVue The purpose of this guide is to: 1. Describe attachment of Table Top Mount to Mounting Adapter (page 2). 2. Describe

More information

Globe Control Valve Series 1a

Globe Control Valve Series 1a Maintenance Globe Control Valve Series 1a are subject to alteration without notice. The text and illustrations do not necessarily display the scope of supply or any ordering of spare parts. Drawings and

More information

Ropox Shower & Changing Bed

Ropox Shower & Changing Bed Ropox Shower & Changing Bed Pre-install / install guide General information Product information It is important to read this manual before mounting and daily use. Product : Ropox Shower & Changing Bed,

More information

Service manual. English. F5 Corpus

Service manual. English. F5 Corpus Service manual English F5 Corpus Introduction The Service Manual is intended for technical personnel who maintain and repair power wheelchairs. It is important that anyone who performs maintenance and

More information

Mounting and Operating Instructions EB EN. Type 3271 and Type 3277 Pneumatic Actuators. Actuator areas: 175v2, 350v2, and 750v2 cm²

Mounting and Operating Instructions EB EN. Type 3271 and Type 3277 Pneumatic Actuators. Actuator areas: 175v2, 350v2, and 750v2 cm² Type 3271 and Type 3277 Pneumatic Actuators Actuator areas: 175v2, 350v2, and 750v2 cm² Translation of original instructions Type 3271 (left) and Type 3277 (right) Pneumatic Actuators Mounting and Operating

More information

User manual. Model Mini, Small, Medium and Large

User manual. Model Mini, Small, Medium and Large User manual Model Mini, Small, Medium and Large 2 Contents Introduction..3 CE marking and labels...3 Safety precautions..3 Prior to first use 4 Meywalk 4 parts...4 Joining the top part and bottom frame.5

More information

OPERATING MANUAL PHASE SEQUENCE AND MOTOR ROTATION DIRECTION TESTER TKF-13

OPERATING MANUAL PHASE SEQUENCE AND MOTOR ROTATION DIRECTION TESTER TKF-13 OPERATING MANUAL PHASE SEQUENCE AND MOTOR ROTATION DIRECTION TESTER TKF-13 v1.5 07.07.2011 Table of contents 1. Safety measures... 2 2. Phase spin direction test... 3 3. Motor shaft spin direction (using

More information

Hydraulic Impact Wrench Type

Hydraulic Impact Wrench Type M a s c h i n e n f a b r i k G m b H Hydraulic Impact Wrench Type 6 1520 0010 Illustration can differ from the original Operation and Maintenance Manual 615200010_en_Version_03 Page 1 of 19 TECHNICAL

More information

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS 2 CE-Sign and Conformity The device meets the requirements of the valid European and national regulations. Conformity has been

More information

Installation Guide. Philips MP20/30/40/50 IntelliVue VHM Wall Mount Kit

Installation Guide. Philips MP20/30/40/50 IntelliVue VHM Wall Mount Kit Installation Guide Philips MP20/30/40/50 IntelliVue VHM Wall Mount Kit The purpose of this guide is to: 1. Describe attachment of Table Top Mount to Mounting Adapter. 2. Describe attachment of Mounting

More information

PROFESSIONAL CORDLESS IMPACT SCREWDRIVER

PROFESSIONAL CORDLESS IMPACT SCREWDRIVER PROFESSIONAL CORDLESS IMPACT SCREWDRIVER Model CIS00 Part No 4500625 OPERATING & MAINTENANCE INSTRUCTIONS GC0309 INTRODUCTION Thank you for purchasing this CLARKE Impact Screwdriver. Before attempting

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS Emergency Cord Switch Type PRS Device identification No.: 91.054 033.001, /.101 and /.201 OPERATING INSTRUCTIONS 2 CE Sign and Conformity The device meets the requirements of the valid European and national

More information

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800 Original instructions Operating Instructions for May 2010 Electric Internal Vibrators BA No. 1092E Series NCX and NCZ These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ

More information

Type 3571 Pneumatic Actuator. Actuator areas: 27 in² 54 in² 116 in². Original instructions. Mounting and Operating Instructions EB 8820 EN

Type 3571 Pneumatic Actuator. Actuator areas: 27 in² 54 in² 116 in². Original instructions. Mounting and Operating Instructions EB 8820 EN Type 3571 Pneumatic Actuator Actuator areas: 27 in² 54 in² 116 in² Original instructions Mounting and Operating Instructions Edition April 2016 Note on these mounting and operating instructions These mounting

More information

A B 0 0 C D E 6 7 G F F H 8 9 K M O O L N I J 1

A B 0 0 C D E 6 7 G F F H 8 9 K M O O L N I J 1 1 2 1 5 4 3 2 2 1 6 3 8 7 1 9 4 C A B 5 0 0 D E 6 G 7 F F H 8 K 9 M O O I J L N 1 GENERAL OPERATIONAL PRECAUTIONS 1. Keep work area clean. Cluttered areas and benches invite accidents. 2. Avoid dangerous

More information

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type Electropneumatic Converters i/p Converter Type 3913-0001 Fig. 1 Type 3913-0001 Electropneumatic Converter with pressure gauge and bracket Mounting and Operating Instructions EB 3913 EN Edition August 2011

More information

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Compact System NRGS 11-2 NRGS Original Installation Instructions English Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive

More information

Mounting and Operating Instructions EB EN. Type 3372 Electropneumatic Actuator. Actuator area: 120 and 350 cm² With Type 3725 Positioner

Mounting and Operating Instructions EB EN. Type 3372 Electropneumatic Actuator. Actuator area: 120 and 350 cm² With Type 3725 Positioner Type 3372 Electropneumatic Actuator Actuator area: 120 and 350 cm² With Type 3725 Positioner Translation of original instructions Type 3372 with 120 cm² actuator area Type 3372 with 350 cm² actuator area

More information

Instructions for Fitting, Operating and Maintenance Canopy Door RE / (St.: )

Instructions for Fitting, Operating and Maintenance Canopy Door RE / (St.: ) EN Instructions for Fitting, Operating and Maintenance Canopy Door 1 818 012 RE / (St.: 12.2010) 12.2010 ENGLISH Contents 1 Safety Instructions... 3 1.1 Qualified persons... 3 1.2 Symbols and signal words

More information

ELECTRIC LIFTER TROLLEY INSTRUCTION MANUAL

ELECTRIC LIFTER TROLLEY INSTRUCTION MANUAL ELECTRIC LIFTER TROLLEY INSTRUCTION MANUAL Imported exclusively by Pacific Hoists Pty. Ltd. & Pacific Hoists Ltd. In support of cancer charities in Australia & New Zealand 2 www.jbstools.com WWW.CHALLENGERHOISTS.COM.AU

More information

SERVICE MANUAL US. Permobil M300/M400. Power Wheelchair

SERVICE MANUAL US. Permobil M300/M400. Power Wheelchair SERVICE MANUAL US Permobil M300/M400 Power Wheelchair How to contact Permobil Head Office of the Permobil group Produced and published by Permobil AB, Sweden Version 2, 2011-06 Article no.: 205261-US-0

More information

Installation and Operating Instructions. Gravity Band Filter Typ PF

Installation and Operating Instructions. Gravity Band Filter Typ PF Installation and Operating Instructions Gravity Band Filter Typ PF GB Table of contents Page 1 Description of product and function... 5 2 Safety instructions... 6 2.1 General instructions... 6 2.2 Instructions

More information

Assembly and Operating Instructions

Assembly and Operating Instructions A35AE FU...A150AE FU en Assembly and Operating Instructions Plug-in drives Important information for: Fitters / Electricians / Users Please forward accordingly! These instructions must be kept safe for

More information

DENTAL LIGHT INSTALLATION AND OPERATION INSTRUCTIONS

DENTAL LIGHT INSTALLATION AND OPERATION INSTRUCTIONS DENTAL LIGHT 70 INSTALLATION AND OPERATION INSTRUCTIONS IMPORTANT After installation is completed, check all the bolts, screws and fasteners to confirm that they are securely fastened. TABLE OF CONTENTS

More information

Installation, Operating and Maintenance Instructions Retractable Door / Art.-Nr.:

Installation, Operating and Maintenance Instructions Retractable Door / Art.-Nr.: Installation, Operating and Maintenance Instructions Retractable Door 06.2008 / Art.-Nr.: 1 818 024 ENGLISH CONTENTS PAGE 1 SAFETY REQUIREMENTS 3 1.1 Symbols and key words used 3 1.2 Designated use 3 1.3

More information

Operatingmanual. Mehrsprachige Anleitung unter Multilingual manuals at. pro BENNING TRITEST BENNING BENNING BENNING.

Operatingmanual. Mehrsprachige Anleitung unter   Multilingual manuals at. pro BENNING TRITEST BENNING BENNING BENNING. Operatingmanual Mehrsprachige Anleitung unter www.benning.de Multilingual manuals at TRITEST pro TRITEST pro D F 8 9 J 1 2 3 6 7 4 5 TRITEST pro T.-Nr: 10115280.01 Stand: 10-2014 10/ 2014 TRITEST pro Operating

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation Type 0131 2/2- or 3/2-way solenoid valve 2/2- oder 3/2-Wege-Magnetventil Électrovanne 2/2 ou 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating

More information

THIS PRODUCT IS FOR PROFESSIONAL LABORATORY USE ONLY USER'S MANUAL. WELLS ENGINE UNIT 230 VOLT Product No. U905, U906, U907, U908

THIS PRODUCT IS FOR PROFESSIONAL LABORATORY USE ONLY USER'S MANUAL. WELLS ENGINE UNIT 230 VOLT Product No. U905, U906, U907, U908 DENTAL, INC. TECHNICAL BULLETIN U807-022510 5860 FLYNN CREEK ROAD READ ALL INSTRUCTIONS P.O. BOX 106 BEFORE PROCEEDING COMPTCHE, CALIFORNIA, U.S.A. 95427 SAVE THIS FOR FUTURE REFERENCE THIS PRODUCT IS

More information

HEINE NT4 MED V

HEINE NT4 MED V HEINE NT4 MED 113594 2018-01-23 V-200.00.601 HEINE NT4 Please read and follow these instructions for use and keep them for future reference. Intended Use The HEINE charger NT4 is to be used exclusively

More information

Hydraulic Motors. Radial Piston Motors with fixed displacement Series RM...X Vg = 250 cm³/u cm³/u. Repair manual. Doc.-No.

Hydraulic Motors. Radial Piston Motors with fixed displacement Series RM...X Vg = 250 cm³/u cm³/u. Repair manual. Doc.-No. Hydraulic Motors Radial Piston Motors with fixed displacement Series RM...X Vg = 250 cm³/u - 900 cm³/u Doc.-No. HM3-005 UK Seite 2 Table of contents 1. General... 3 2. Dismantling the distributor unit...

More information

Installation Guide VHM Arm Kit for Philips Heartstart MRx and Heartstart XL+

Installation Guide VHM Arm Kit for Philips Heartstart MRx and Heartstart XL+ Installation Guide VHM Arm Kit for Philips Heartstart MRx and Heartstart XL+ The purpose of this guide is to: 1. Describe installation of Arm in channel (page 2). 2. Describe mounting of defibrillator

More information

Mounting and Operating Instructions EB EN. Type 3271 Pneumatic Actuator. Actuator area: 1000 cm². Translation of original instructions

Mounting and Operating Instructions EB EN. Type 3271 Pneumatic Actuator. Actuator area: 1000 cm². Translation of original instructions Type 3271 Pneumatic Actuator Actuator area: 1000 cm² Translation of original instructions Type 3271 Pneumatic Actuator Mounting and Operating Instructions Edition April 2018 Note on these mounting and

More information

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet. Description Marking The ANTARES ExtSet makes it possible to distribute the Remote I/O ANTARES modules of an explosion-protected Remote I/O system ANTARES among a maximum of 4 metal mounting rails. For

More information

Installation manual wall-mounted distributor

Installation manual wall-mounted distributor EN Installation manual wall-mounted distributor EN 60003233 Issue 11.2016 2016-14-11 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2

More information

Fitting Instructions ECE. type-approved. 1 Component overview 2 Warnings 3 Assembling 4 Light bulb replacement. Info:

Fitting Instructions ECE. type-approved. 1 Component overview 2 Warnings 3 Assembling 4 Light bulb replacement. Info: ENG 10/02 Fitting Instructions ECE type-approved 1 Component overview 2 Warnings 3 Assembling 4 Light bulb replacement Info: www.kellermann-online.com Dear customer, Thank you for purchasing the BL_1000.

More information

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator) Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator) Linear Actuator with Type 3260 Control Valve Rotary actuator with lever system Linear actuator with Type 3321 (V2001) Control

More information

HD18F2M1.

HD18F2M1. HD18F2M1 www.blackanddecker.com 3 2 1 5 A 4 5 B 4 7 10 9 C 4 6 D 4 8 1 11 12 E 2 F 3 2 G H 13 I 14 13 14 K 3 J 3 L M 16 15 4 Intended use Your Black & Decker hand held vacuum cleaner has been designed

More information

Type Operating Instructions. Angle Seat Motor Valve Compact. BM24C, BM24C/I BM24C/IOS, BM230C/IOS with and without spring return

Type Operating Instructions. Angle Seat Motor Valve Compact. BM24C, BM24C/I BM24C/IOS, BM230C/IOS with and without spring return Operating Instructions Angle Seat Motor Valve Compact Type 70 Valid For Actuators: BM4, BM5, BM30, BM4C, BM4C/I BM4C/IOS, BM30C/IOS with and without spring return Version: 08/004 W70e.doc Art.-Nr: 70 Bunsenstrasse

More information

1.Safe testing IMPORTANT:

1.Safe testing IMPORTANT: Electricity is dangerous and can cause injury and death. Always treat it with the greatest of respect and care. If you are not quite sure how to proceed, then stop, take advice from a qualified person.

More information

OPERATING MANUAL. BAK Thermoplastic Welding Technology AG 1

OPERATING MANUAL. BAK Thermoplastic Welding Technology AG 1 OPERATING MANUAL BAK Thermoplastic Welding Technology AG 1 SAFETY Danger to life Unplug the tool before opening it as live components and connections are exposed. Danger of fire and explosion in case of

More information

Operating Instructions

Operating Instructions Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Notes Regarding Safety...3 4 Intended Area of Application...4 5 Technical Data...5

More information

2006 MINI Cooper SUSPENSION Wheels & Tires - Repair Instructions - Cooper (1.6L) R50/W10 & Cooper S

2006 MINI Cooper SUSPENSION Wheels & Tires - Repair Instructions - Cooper (1.6L) R50/W10 & Cooper S WHEELS 2002-05 SUSPENSION Wheels & Tires - Repair Instructions - Cooper (1.6L) R50/W10 & Cooper S 36 10 300 REMOVING OR INSTALLING FRONT OR REAR WHEEL NOTE: For Special Tool identification, see WHEEL AND

More information

Instruction Manual. Made in Israel Distributed by:

Instruction Manual. Made in Israel Distributed by: Instruction Manual Made in Israel Distributed by: 1333 South Claudina Street Anaheim, CA 92805, U. S. A. Toll Free: (800) 854 9305 Telephone: (714) 533 2221 FAX: (714) 635 7539 Web Site: http://www.mettlerelectronics.com

More information

Operating manual. ZSK Automatic Bobbin Winder 230V 50Hz/60/Hz / Z

Operating manual. ZSK Automatic Bobbin Winder 230V 50Hz/60/Hz / Z Operating manual ZSK Automatic Bobbin Winder 230V 50Hz/60/Hz 574 228 / Z-008-1380 02418V10 [GB] - 2016 Subject to change! Änderungen vorbehalten! ZSK Stickmaschinen GmbH Printed in Germany [ GB ] 02418V10

More information

Before use please read & understand this manual, paying particular attention to the safety instructions.

Before use please read & understand this manual, paying particular attention to the safety instructions. OPERATOR S MANUAL AND PARTS LIST 800W ELECTRIC TILLER - THET-A Sales & Helpline 01793 333212 www.thehandy.co.uk Before use please read & understand this manual, paying particular attention to the safety

More information

Linear Luminaire for Fluorescent Lamps

Linear Luminaire for Fluorescent Lamps Linear Luminaire for Fluorescent Lamps Operating instructions Additional languages www.stahl-ex.com General Information Contents 1 General Information...2 1.1 Manufacturer...2 1.2 Information regarding

More information

Introduction. The words WARNING, CAUTION and NOTE carry special meanings and should be carefully reviewed.

Introduction. The words WARNING, CAUTION and NOTE carry special meanings and should be carefully reviewed. Operations/ Maintenance Manual Important Information File in your maintenance records Medical Visum Exam Light Model LL305 For parts or technical assistance call 800 327 0770 (option 2) Table of Contents

More information

User Manual Rittal PMC UPS 6kVA

User Manual Rittal PMC UPS 6kVA User Manual Rittal PMC UPS 6kVA Germany Rittal GmbH & Co. KG Auf dem Stützelberg D-35745 Herborn Tel.: ++49-27 72-5 05-0 Fax: ++49-27 72-5 05-23 19 Internet: www.rittal.de 26 Contents 1. Introduction...

More information

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: & HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: 5460600 & 5460595 OPERATING & MAINTENANCE INSTRUCTIONS GC0610 INTRODUCTION Thank you for purchasing this CLARKE Halogen Floodlight. Before attempting

More information

Original Operating Manual

Original Operating Manual matev GmbH Nürnberger Str. 50 90579 Langenzenn T +49 (0) 9101 9087-0 F +49 (0) 9101 9087-20 info@matev.eu www.matev.eu Original Operating Manual Front Power System und Front PTO shaft FPS- JD X 950 R for

More information

Instructions for Fitting, Operating and Maintenance

Instructions for Fitting, Operating and Maintenance EN Instructions for Fitting, Operating and Maintenance Retractable Door 1 818 024 RE / 10.2011 ENGLISH Contents 1 Safety Instructions... 3 1.1 Qualified persons... 3 1.2 Symbols and signal words used...

More information

Maintenance Information

Maintenance Information 80234313 Edition 1 June 2006 Air Grinder, Die Grinder, Sander and Belt Sander Series G1 (Angle) Maintenance Information Save These Instructions WARNING Always wear eye protection when operating or performing

More information

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL MOTORTECH Tools & Test Equipment for Ignition Systems P/N 01.10.019 Rev. 01/2013 Copyright Copyright 2012 MOTORTECH GmbH. All rights reserved. Distribution

More information

Mounting and Operating Instructions

Mounting and Operating Instructions Mounting and Operating Instructions EB 8310-6 EN Translation of original instructions Type 3271 Type 3277 Type 3271 and Type 3277 Pneumatic Actuators Actuator area: 240, 350, and 700 cm² Edition March

More information

Operating Manual for extrusion valve MMKD-40 KV/LV/LVP

Operating Manual for extrusion valve MMKD-40 KV/LV/LVP Operating Manual for extrusion valve MMKD-40 KV/LV/LVP Read this manual carefully before installing, operating or servicing this equipment. Keep always handy for further use. ALFRED SCHÜTZE Apparatebau

More information

AQUATEC R / AQUATEC F / AQUATEC XL. Bathlift Operating instructions

AQUATEC R / AQUATEC F / AQUATEC XL. Bathlift Operating instructions AQUATEC R / AQUATEC F / AQUATEC XL Bathlift Operating instructions 1 2 3 4 5 6 7 8 9 10 11 Contents 1 General instructions................. 3 1.1 Introduction......................... 3 1.2 Proper use.........................

More information

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO:

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: AIR FILTER MODEL NO: AF1000 PART NO: 6471160 OPERATION & MAINTENANCE INSTRUCTIONS 1208 INTRODUCTION Thank you for purchasing this Clarke Air Filter. Before you try to use this product, read this manual

More information

Maintenance Information

Maintenance Information 80234313 Edition 2 May 2014 Air Grinder, Die Grinder, Sander and Belt Sander Series G1 (Angle) Maintenance Information Save These Instructions Product Safety Information WARNING Failure to observe the

More information

Operating Instructions. International English. CCS Dust Extractor

Operating Instructions. International English. CCS Dust Extractor Operating Instructions International English CCS Dust Extractor Electric Cast Saw Dust Removal System Warnings & Safety Rules WARNING!: THIS EQUIPMENT MUST BE EARTHED! Danger!: Possible explosion hazard

More information

Operating Instructions. Angle Seat Control Valve. Type 7020

Operating Instructions. Angle Seat Control Valve. Type 7020 Operating Instructions Angle Seat Control Valve Type 7020 With: Digital Positioner Type 8048 Electro-pneumatic Positioner Type 8047 Pneumatic Positioner Type 8047 Version: 02/2006 Manual-7020e.doc Art.-No:

More information

Heavy Duty Miniature Quick-Change Applicator (End-Feed Type) with Mechanical or Air-Feed Systems

Heavy Duty Miniature Quick-Change Applicator (End-Feed Type) with Mechanical or Air-Feed Systems Heavy Duty Miniature Quick-Change Applicator (End-Feed Type) with Mechanical or Air-Feed Systems Instruction Sheet 408-8039 02 JUN 16 Rev G Ram Post Wire Disc Insulation Disc Insulation Crimper Stripper

More information

OPERATING INSTRUCTIONS INDEPENDENT WHEEL SUSPENSION RL 75 E/EC FRONT AXLE/TAG AXLE RL 75 A

OPERATING INSTRUCTIONS INDEPENDENT WHEEL SUSPENSION RL 75 E/EC FRONT AXLE/TAG AXLE RL 75 A INDEPENDENT WHEEL SUSPENSION RL 75 E/EC FRONT AXLE/TAG AXLE RL 75 A 587.97.90 en Preface This documentation has been developed for specialized staff trained by ZF Friedrichshafen AG for repair and maintenance

More information

Operating Instructions

Operating Instructions Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Conformity to Standards...3 5 Intended Field of Application...3

More information

OPERATION AND MAINTENANCE MANUAL

OPERATION AND MAINTENANCE MANUAL WREN IBT SERIES HYDRAULIC TORQUE WRENCHES IBT SQUARE DRIVE SERIES OPERATION AND MAINTENANCE MANUAL FOR WREN Products: POINT 75, 1IBT, 3IBT, 5IBT, 8IBT, 10IBT, 20IBT, 25IBT, 35IBT, 50IBT SQUARE DRIVE HYDRAULIC

More information

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-707A & AEU-707AV2 Implant / Surgery Systems

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-707A & AEU-707AV2 Implant / Surgery Systems OPERATION AND MAINTENANCE INSTRUCTION MANUAL AEU-707A & AEU-707AV2 Implant / Surgery Systems TABLE OF CONTENTS: Introduction.........................1 Package Contents....................1 Setting Up the

More information

Maintenance Information

Maintenance Information 04581245 Edition 2 May 2014 Air Grinder, Die Grinder and Sander Series G2 (Angle) Maintenance Information Save These Instructions Product Safety Information WARNING Failure to observe the following warnings,

More information

Installation Instructions LamboStyleDoors (The instruction are to be used as a reference. Please repeat for both doors)

Installation Instructions LamboStyleDoors (The instruction are to be used as a reference. Please repeat for both doors) Installation Instructions LamboStyleDoors (The instruction are to be used as a reference. Please repeat for both doors) Mercedes C-Class Sport coupé type W203 Part number 500 25 009 Pre installation check

More information

Cordless Screwdriver

Cordless Screwdriver ENGLISH Cordless Screwdriver MODEL 6796D MODEL 6796FD MODEL 6797D MODEL 6797FD MODEL 6798D MODEL 6798FD 00260 I N S T R U C T I O N M A N U A L WARNING: For your personal safety, READ and UNDERSTAND before

More information

SM6. instructions for use. GAM cubicle (1250A) MV distribution factory built assemblies at your service. Anglais

SM6. instructions for use. GAM cubicle (1250A) MV distribution factory built assemblies at your service. Anglais SM6 Anglais MV distribution factory built assemblies at your service instructions for use GAM cubicle (1250A) foreword... 3 symbols and conventions... 3 as per iso 3864---2... contact the Schneider Electric

More information

Original Operating Manual

Original Operating Manual matev GmbH Nürnberger Str. 50 90579 Langenzenn T +49 (0) 9101 9087-0 F +49 (0) 9101 9087-20 info@matev.eu www.matev.eu Original Operating Manual Snow blade SRM-FB 120 CD Angle adjustment mechanical Version

More information

Translation of the Original operating instructions Lifting device Z 70 /...

Translation of the Original operating instructions Lifting device Z 70 /... Translation of the Original operating instructions Lifting device Z 70 /... Content 1. Lifting device / Correct use according to regulations 2. Basic principles 3. General information 4. Special remarks

More information

Mounting and Operating Instructions EB 5868/5869 EN

Mounting and Operating Instructions EB 5868/5869 EN Electric Control Valves Types 3213/5857, 3213/5824, Types 3214/5824, 3214/3374, 3214/3274 with safety function: Types 3213/5825, 3214/5825, 3214/3374, 3214/3274 Pneumatic Control Valves Types 3213/2780-1,

More information

Drive shaft Operating Instructions BA 42/07

Drive shaft Operating Instructions BA 42/07 www.reinhausen.com Drive shaft Operating Instructions BA 42/07 Contents Contents 1 General... 3 1.1 Safety labels... 3 1.2 Safety instructions... 3 1.3 Specified application... 3 2 Design/Types... 4 3

More information

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com CONTENTS PRM-2 & PRM-3 1. Warranty...3

More information

Operator's manual. TruTool F 140 (1A1) english

Operator's manual. TruTool F 140 (1A1) english Operator's manual TruTool F 140 (1A1) english Table of contents 1. Safety...3 2. Description...5 2.1 Intended use...6 2.2 Technical data of the TruTool F 140...7 2.3 Lock seams...8 3. Tool assembly...10

More information

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference Please dispose of Packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

Bowl feeder WV401-1 / Translation of operating and installation instructions

Bowl feeder WV401-1 / Translation of operating and installation instructions Bowl feeder WV401-1 / 402-1 Translation of operating and installation instructions Copyright by Afag GmbH This operation instruction applies to: Bowl feeder WV401-1 Bowl feeder WV402-1 Type 230 V / 50

More information

Series 1b Control Valve

Series 1b Control Valve Maintenance Instructions Series 1b Control Valve 1. General These instructions are intended to assist the user on assembling and repairing Series 1b Control Valves. Technical specifications, as a result

More information

Globe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN

Globe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN Globe Valve Type 3241 Fig. 1 Type 3241 Globe Valve Mounting and Operating Instructions EB 8015-1 EN Edition July 2012 Contents Contents Page 1 Design and principle of operation.................... 4 2

More information

OLYMPIAN MODEL 740 Operation and Service Manual

OLYMPIAN MODEL 740 Operation and Service Manual OLYMPIAN MODEL 740 Operation and Service Manual P/N 133911-102 FCI MANUAL P/N 133865-001 Data herein has been verified and validated and believed adequate for the intended use. If the machine or procedures

More information

Re.Formance Line INSTRUCTION MANUAL 1703

Re.Formance Line INSTRUCTION MANUAL 1703 Re.Formance Line INSTRUCTION MANUAL 1703 320.8779.02 / 1703 Re.Formance Line Table of contents 1. Overview... 3 1.1 Re.Forma Hi.... 3 1.2 Re.Forma... 3 1.3 Re.Forma Lite.... 3 2. Notes... 4 2.1 Warranty

More information

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3 Operating Instructions Pneumatic Control Valve Low Temperature Type 8026 Series GS3 With: Digital Positioner Type 8048 Electro-pneumatic Positioner Type 8047 Pneumatic Positioner Type 8047 Version: 03/2006

More information

Power Transmission. Installation and Operating Instructions for Brake Caliper DV / DH 020 FKM. E e.

Power Transmission. Installation and Operating Instructions for Brake Caliper DV / DH 020 FKM. E e. Power Transmission Installation and Operating Instructions for Brake Caliper DV / DH 020 FKM Schaberweg 30-34 Telephone +49 6172 275-0 61348 Bad Homburg Telefax +49 6172 275-275 Germany www.ringspann.com

More information