Section C CONTORLS INDEX. CS Series CONSPEC Control Stations FXCS Series. Seal-X Factory Sealed Cover Assemblies

Size: px
Start display at page:

Download "Section C CONTORLS INDEX. CS Series CONSPEC Control Stations FXCS Series. Seal-X Factory Sealed Cover Assemblies"

Transcription

1 i Section ONTORLS INDEX S Series ONSPE ontrol Stations...-4 FXS Series Seal-X Factory Sealed over Assemblies S Series Dimensional Data atalog Logic S Series ONSPE Boxes and overs...8 XS/XS/SWB Series ontrol Stations External Sealing Required S Series ONSPE Operators Push Buttons, Pilot Lights ontrol Switches, Ammeters ID Labels, Accessories P Series ONSPE ontrol Panels P Series Dimensional Data SWB Series Device Boxes XS Series over Assemblies ontrol Stations XS Series overs...36 FXS Series Seal-X Factory Sealed ontrol Stations...-7 FXS/XS Series Accessories, Replacement Parts FXB Series Seal-X Splice Boxes...3 XS Series Tumbler Switch...38

2 Section ii ONTORLS INDEX XAL/XAS Series Fire Alarm Stations...39 B7 Series Prism Magnetic Motor Starters B7 Series Prism ombination Starters...56 G Series ustom ontrol Panel Operators Push Buttons, Pilot Lights, Selector Switches B7 Series Dimensions, Accessories, atalog Logic B7 Series Overload Heaters, Non-Reversing Data...59 Y7 Series Motor Starters-Magnetic Line Starters...60 G Series Specialty Operators...46 Y7 Series ombination Motor Starter...61 G Series Operator Bodies...47 Y7 Series Motor Starters-Modifications...6 G Series Accessories/Replacement Parts G Series Operator Ordering System and Symbols XSD/XSX/FXSD/FXSX Series Manual Motor Starting Switches...63 XSD/XSX/FXSD/FXSX Series Heaters, Dimensions...64 XMSW Series Manual Line Starters...65

3 R S SERIES ONTROLS ONTROL STATIONS lass I, Div., Groups A,B,,D lass l, Zones 1 &, Groups II, llb, lla lass II, Div. 1 &, Groups E,F,G1 lass III NEMA 3, 4, 4x (A)Ex de II T6 IP66 FRP Enclosure Stainless Steel Enclosure FEATURES-SPEIFIATIONS Applications Hazardous and corrosive environments such as refineries, chemical plants, water treatment and bio gas plants, and wherever a combustible gas-air mixture or combustible dust may occur. Features Enclosures of Fiberglass Reinforced Polyester or Stainless Steel. Durable EPDM gasket on enclosure is concealed to protect it from damage or premature aging by UV light and chemical elements Snap-on mounting of individual explosion-protected control components to notched DIN-like rail ontact element utilizes a parallel bridge contact with a four point (H- contact) to ensure the utmost reliability even with very low control voltages and currents Fluorosilicate gasket in standard pushbutton actuators is suitable for a wide range of atmospheric conditions (-50 to 40 ) LED Pilot lights (incorporating advanced voltage-sensing electronics) operate on any voltage from 0V- 54V, A or D ontrol switches in many configurations Illuminated (Push-To-Test) push buttons, ammeters, potentiometers and other control components available No external seals required for most applications THE Standard in Hazardous Location ontrol Pilot Light Bezel Station I.D. Label (optional) Recessed EPDM Gasketing RUN Actuator Gasket Two Types of Enclosure Materials Fiberglass Reinforced Polyester (FRP) 316L Stainless Steel Integral Mounting Slots (holes) Explosion Protected LED Pilot Light Dual Push-Button Actuator omponent Mounting Rail Spring Washer & Retainer Nut Explosion Protected ontact Block Ground Plate With Terminals Stainless Steel over Screws onduit Hub or able Gland Entry 1SA ertified for lass II, Div. 1&, EFG. UL LIsted for lass II, Div., FG. Easy hange-out omponents Snap in Place

4 R S SERIES ONTROLS ONTROL STATIONS - STANDARD ONFIGURATIONS 3 Start Push Button Station Start/Stop Push Button Station E-Stop Push Button Station Pilot Light Station lass I, Div., Groups A,B,,D lass l, Zones 1 &, Groups II, llb, lla lass II, Div. 1 &, Groups E,F,G1 lass III NEMA 3, 4, 4X (A)Ex de II T6 IP66 FEATURES-SPEIFIATIONS The control stations on this page are the most commonly used configurations, including combinations of pilot lights and push buttons. See the following pages for components to configure custom control stations and panels. Wiring Entry Logic Insert one of the digits below to complete the control station catalog number. BOXES WITH INTERNAL GROUND PLATE (for M/T/TE able onnectors) 1/" NPT Top Feed A 1/" NPT Bottom Feed B 1/" NPT Feed Through 3/4" NPT Top Feed D 3/4" NPT Bottom Feed E 3/4" NPT Feed Through F BOXES WITH ONDUIT HUB 1/" NPT Top Feed 1/" NPT Bottom Feed 1/" NPT Feed Through 3/4" NPT Top Feed 3/4" NPT Bottom Feed 3/4" NPT Feed Through BOXES WITH NON-METALLI ABLE GLAND (Standard for IE/ENELE) M5 ompression Gland Top Feed 6 M5 ompression Gland Bottom Feed 7 M5 ompression Gland Feed Through 8 Special 9 1SA ertified for lass II, Div. 1&, EFG. UL Listed for lass II, Div., FG S MOMENTARY SINGLE PUSH BUTTON ATALOG NUMBER SF14UO11 SS14UO11 ATALOG NUMBER ONTAT ARRANGEMENT IE NEMA S MOMENTARY START-STOP PUSH BUTTONS SF4UO11UO1 SS4UO11UO1 ATALOG NUMBER ONTAT ARRANGEMENT IE NEMA S MAINTAINED EMERGENY STOP PUSH BUTTON SF14150 SS14150 S SINGLE PILOT LIGHT ATALOG NUMBER SF14PLRO SS14PLRO ONTAT ARRANGEMENT IE NEMA I-0 ONTAT ARRANGEMENT IE NEMA X X 1 START STOP ONTAT BLOKS ONTAT BLOKS 1 N.O. / 1 N.. 1 N.O. / 1 N.. ONTAT BLOKS VOLT BUTTON OLOR BUTTON OLOR BUTTON OLOR OLOR NAMEPLATE MARKING NAMEPLATE MARKING NAMEPLATE MARKING NAMEPLATE MARKING Wiring entry: 4=3/4" NPT Bottom Feed. For other entries, see Wiring Entry Logic table at left. Housing material: (F) FRP, (S) Stainless Steel. 1 N.O. / 1 N.. Green Start Green Red Start Stop N.. Red Large E-Stop 0V-54V A / D Red LED

5 R 4 S SERIES ONTROLS ONTROL STATIONS - STANDARD ONFIGURATIONS Pilot Light & Start/Stop Push Selector Switch Station Pilot Light and Selector Switch Station Button Station Station Pilot Light & Push Button lass I, Div., Groups A,B,,D lass l, Zones 1 &, Groups II, llb, lla lass II, Div. 1 &, Groups E,F,G1 lass III NEMA 3, 4, 4X (A)Ex de II T6 IP66 FEATURES-SPEIFIATIONS The control stations on this page are the most commonly used configurations, including combinations of pilot lights, push buttons and selector switches. See the following pages for components to configure custom control stations and panels. Wiring Entry Logic Insert one of the digits below to complete the control station catalog number. BOXES WITH INTERNAL GROUND PLATE (for M/T/TE able onnectors) 1/" NPT Top Feed 1/" NPT Bottom Feed 1/" NPT Feed Through 3/4" NPT Top Feed 3/4" NPT Bottom Feed 3/4" NPT Feed Through BOXES WITH ONDUIT HUB A B D E F 1/" NPT Top Feed 0 1/" NPT Bottom Feed 1 1/" NPT Feed Through 3/4" NPT Top Feed 3 3/4" NPT Bottom Feed 4 3/4" NPT Feed Through 5 BOXES WITH NON-METALLI ABLE GLAND (Standard for IE/ENELE) M5 ompression Gland Top Feed M5 ompression Gland Bottom Feed M5 ompression Gland Feed Through Special 1SA ertified for lass II, Div. 1&, EFG. UL LIsted for lass II, Div., FG S PILOT LIGHT (RED LED)/MOMENTARY DOUBLE PUSH BUTTONS ATALOG ONTAT ARRANGEMENT VOLT ONTAT NUMBER IE NEMA BLOKS SF4PLROU31 SS4PLROU31 S PILOT LIGHT (RED LED)/MOMENTARY START-STOP PUSH BUTTONS ATALOG NUMBER SF334PLROU011U01 SS334PLROU011U01 ONTAT ARRANGEMENT IE NEMA S MAINTAINED 3-POSITION SELETOR SWITH ONTAT ARRANGEMENT IE NEMA ONTAT ARRANGEMENT IE NEMA -Pos./-Pole 3-Pos./-Pole S PILOT LIGHT/MAINTAINED -POSITION SELETOR SWITH OFF ON HAND OFF AUTO 0V-54V, A/D VOLT 0V-54V, A/D S MAINTAINED -POSITION SELETOR SWITH ATALOG ONTAT ARRANGEMENT ONTAT NUMBER IE NEMA BLOKS SF14NO1 SS14NO1 ATALOG NUMBER SF14N73 SS14N73 ATALOG NUMBER SF4PLRON01 SS4PLRON X1 X X X START START OFF STOP STOP ON ONTAT BLOKS VOLT 1 N.O./1 N.. ONTAT BLOKS 1 N.O. / 1 N.. 1 N.O. / 1 N.. BUTTON OLOR BUTTON OLOR ONTAT BLOKS BUTTON OLOR Green Red BUTTON OLOR Green Red OLOR 0V-54V, A/D -Pos./-Pole Red LED NAMEPLATE MARKING Start Stop NAMEPLATE MARKING Start Stop NAMEPLATE MARKING Off-On NAMEPLATE MARKING H-O-A NAMEPLATE MARKING Off-On Wiring entry: 4=3/4" NPT Bottom Feed. For other entries, see Wiring Entry Logic table at left. Housing material: (F) FRP, (S) Stainless Steel.

6 S SERIES ONTROLS ONTROL STATIONS DIMENSIONAL DATA 5 FRP Enclosure Stainless Steel Enclosure FEATURES-SPEIFIATIONS FRP Dimensions 0." (5.5) 3.1" (80).8" (70) 0.3" (7) 0." (5.5) 3.1" (80).8" (70) 3.1" (80) 0." (5.5) 0.3" (7) 0." (5.5) 3.1" (80).8" (70).43" (11) 3.78 (97) 3.1" (80) 0.3" (7) 0." (5.5).8" (70) A B 5.5" (140) 7.3" (185) A B 5.5" (140) 7.3" (185) A B 3.7" (94) 5.5" (139) 0.3" (7) ø 0." ø (5.5) ø 0." ø (5.5) A B ø 0." (ø 5.5) 1.9" (48) 3.7" (93) ø 0." ø (5.5) 0." (5.5) 0." (5.5) 0." (5.5) 0." (5.5) SF1/SF SF 33 SF 11 ompact SF Deep for 4 Pole Switches Steel Dimensions SS 1 SS SS 33

7 6 S SERIES ONTROLS ONTROL STATION ATALOG LOGI ENLOSURES ENLOSURE SPEIFIATION ontrol Station Material Size Entry Type S [ _ ] [ ] [ _ ] Use the logic on this and the following page to configure a custom station. First check standard control station configurations on pages 3 & 4. Note that not all combinations are possible due to space/actuator constraints. F Fiberglass Reinforced Polyester S 316 Stainless Steel 11 1 Device ompact (FRP Only) 1 1-Device -Device ONDUIT HUB 0 1/" Hub top feed 1 1/" Hub bottom feed 1/" Hub feed-thru 3 3/4" Hub top feed 4 3/4" Hub bottom feed 5 3/4" Hub feed-thru OMPRESSION GLAND (M5) 6 Gland top feed 7 Gland bottom feed 8 Gland feed-thru 9 Special (specify) 33 3-Device THREADED OPENING* A 1/" NPS plate top feed Pilot Light & Push Button Station Example: SF4PLR0U Device Expanded 73 1-Device Deep (FRP Only) 84 -Device Deep (FRP Only) B 1/" NPS plate bottom feed 1/" NPS plate feed-thru D 3/4" NPS plate top feed E 3/4" NPS plate bottom feed F 3/4" NPS plate feed-thru G 1/" NPS plug feed-thru H 3/4" NPS plug feed-thru *Threaded opening for use with approved connectors, not for conduit (Suggested Killark MX Series). Other special entries available on request. 4 Ammeter 54 Ammeter Plus 1 Device 94 Ammeter Plus 1 Device Deep (FRP Only)

8 S SERIES ONTROLS ONTROL STATION ATALOG LOGI DEVIES 7 DEVIE SPEIFIATION (1, OR 3 DEVIE) Top Middle (or Ammeter Scale) Bottom (if required) [ ] [ ] [ ] DEVIES PUSH BUTTONS USING ONTAT BLOKS ontact type X 1 N.O. Y 1 N.. U 1 N.O. / 1 N.. O N.O N.. M N.. / 1 N.O. W 1 N.. / N.O. T 3 N.. R 3 N.O. ontact type X 1 N.O. Y 1 N.. U 1 N.O. / 1 N.. O N.O. N.. PL Pilot light (LED) olor SA Amber SB Blue SG Green SR Red SW White ONTROL SWITHES Actuator type N Non-locking S Small locking* L Large locking* *These Actuators require larger (expanded) enclosure Push Button Actuator type 01 Standard momentary 0 Booted momentary 03 Black momentary small mushroom 1 Black maintained small mushroom 10 Small maintained E-STOP mushroom 14 Large red momentary mushroom 15 Large maintained E-STOP mushroom 09 E-STOP mushroom with key Type 07 Momentary -position key 08 Maintained -position key (Rem.in both) 18 Maintained -position key (Rem.left) 8 Maintained -position key (Rem.right) 38 Maintained 3-position key (Rem.all positions) R Switch -position maintained T Switch -position momentary RR Switch 3-position maintained RT Switch 3-position momentary right TR Switch 3-position momentary left TT Switch 3-position momentary left & right olor A Amber / yellow B Blue G Green R Red W White ontact type X 1 N.O. Y 1 N.. U 1 N.O. / 1 N.. O N.O. N.. Switch arrangement -pole, digit 0 -position standard OFF-ON 05 -position standard ON-OFF 16 -position standard LOAL-REMOTE 7 3-position standard HAND-OFF-AUTO 38 3-position standard STOP-RUN-START 4-pole, 3 digit (deep enclosures only): 10 -position standard OFF-ON 106 -position LOAL-REMOTE position 4P HOA See page 13 for other switch arrangements. Legend 0 NONE 1 START STOP 3 ON 4 OFF 5 RUN 6 RESET 7 OPEN 8 LOSE 9 Special (specify) Space Saving Double Push Button 3 Double momentary U 1 N.O. / 1 N U31 START(1 NO)-STOP(1 N)......or.....U39 specify legends (1 NO,1 N) D N.O. / N D31 START( NO)-STOP( N)......or.....D39 specify legend ( NO, N) Note - N.O./ N.. for use with enclosure sizes 1, 64 and 54. SELETOR SWITH ATUATOR PILOT LIGHTS ILLUMINATED PUSHBUTTONS (MOMENTARY) Legend 0 NONE 1 OFF-ON ON - OFF 3 HAND-OFF-AUTO 4 LOAL-REMOTE 5 STOP-RUN-START 6 O -I 7 one line of text 8 two lines of text 9 Special (specify) Legend Same number as push buttons Legend Same number as push buttons Legend 0 NONE 1 OFF-ON ON - OFF 3 HAND-OFF-AUTO 4 LOAL-REMOTE 5 STOP-RUN-START 6 O -I 7 one line of text 8 two lines of text 9 Special (specify) SUFFIXES AND SPEIAL DEVIES PUSH BUTTON LOKOUT / GUARD LK01 Standard momentary lockout (01) LK0 Standard momentary exclusion (01) LK03 Small mushroom guard (03,10,1) LK10 Small mushroom lockout (03,10,1) LK11 Small mushroom pin & chain lockout (03,10,1) LK0 Small mushroom exclusion (03,10,1) LK3 Double pushbutton lockout, 1-device (3) Push Button Example: SF4 U011 U01 LK01 FRP -Device Enclosure with 3/4" NPT Hub on bottom side + START pushbutton (1NO/1N)+ Lockout STOP (1NO/1N) SS LK SST 1-Device Enclosure with 3/4" NPT Feed Through + Red Mushroom E-STOP with lockout (N) AMMETERS Direct reading (X overload) AD Ammeter for direct wiring Scales / 0.04 A / 0.1 A / A / 8 A / 0 A / 30 A Indirect for ontrol Transformer (X overload) / / / /375 A1 Ammeter 1 Amp / /500 control transformer / /750 or / / / /150 A5 Ammeter 5 Amp / /1500 control transformer / / / /4000 Ammeter Example: SF94 A1 001 N FRP Ammeter plus Deep Device Enclosure w/ 1/" NPT Feed-through + Ammeter for T 1A (scale 0-00A) + 4-pole control switch (Hand-Off-Auto) POTENTIOMETERS UL PENDING Dial Increments Resistance (Ohm) Range: P scale K 11 0K K 1 470K P scale K 13 1M 04 1K 09 47K 14.M P6 0-6 scale 05.K K M ontrol stations can include terminals or plugged device openings for future use. AESSORIES T1 Terminals (8 x 1 AWG) P733 Device close-up plug

9 R 8 S SERIES ONTROLS ENLOSURES FRP Stainless Steel System ertifications Apply FEATURES-SPEIFIATIONS Features ontrol station housings available in 1 through 3 gang standard push button configurations as well as ammeter housings All boxes come standard with a DIN like rail for component snap-onmounting. See components on following pages. A wide variety of conduit or cable entries can be specified Technical Data-Housings Housing Material and Gasketing Fiberglass Reinforced Polyester (FRP) with EPDM recessed gasketing 316 Stainless Steel with concealed die cut EPDM gasketing Wiring Entry Logic Insert one of the digits below to complete the box or box and cover part number. BOXES WITH OPENINGS (for M/T/TEK able onnectors) 1/" NPT Top Feed A 1/" NPT Bottom Feed B 1/" NPT Feed Through 3/4" NPT Top Feed D 3/4" NPT Bottom Feed E 3/4" NPT Feed Through F BOXES WITH ONDUIT HUB 1/" NPT Top Feed 1/" NPT Bottom Feed 1/" NPT Feed Through 3/4" NPT Top Feed 3/4" NPT Bottom Feed 3/4" NPT Feed Through BOXES WITH NON-METALLI ABLE GLAND (Standard for IE/ENELE) M5 ompression Gland Top Feed M5 ompression Gland Bottom Feed M5 ompression Gland Feed Through Special ONTROL HOUSING BOX AND OVER DESRIPTION SINGLE ONTROL OPENING SF-14 FRP SS-14 Stainless Steel TWO ONTROL OPENING SF-4 FRP SS-4 Stainless Steel THREE ONTROL OPENING SF-334 FRP SS-334 Stainless Steel AMMETER OPENING SF-44 FRP SS-44 Stainless Steel AMMETER OPENING AND SINGLE ONTROL DEVIE OPENING SF-544 FRP SS-544 Stainless Steel EXPANDED TWO GANG (3 GANG BOX WITH ONTROL DEVIE OPENINGS) SF-644 FRP SS-644 Stainless Steel EXTRA DEEP SINGLE ONTROL DEVIE OPENING SF-734 FRP EXTRA DEEP TWO ONTROL DEVIE OPENING SF-844 FRP EXTRA DEEP AMMETER OPENING WITH SINGLE ONTROL OPERATOR SF-944 FRP OMPAT SINGLE ONTROL DEVIE OPENING SF-114 FRP Wiring entry: 4=3/4" NPT Bottom Feed. For other entries, see Wiring Entry Logic table at left. Box and cover available separately.

10 R S SERIES ONTROLS PUSH BUTTONS 9 System ertifications Apply FEATURES-SPEIFIATIONS PUSH BUTTON ATUATORS Features Push button actuators are for use with KSB contact blocks. SINGLE PUSH BUTTONS WITH BLAK LEGEND DIS KSA-001 KSA-00 DESRIPTION Standard Momentary Push Button (supplied with black legend disk*) Booted Momentary Push Button (supplied with black legend disk*) MUSHROOM HEAD PUSH BUTTONS NO LEGEND DISS.7" (69) KSA-003 Black Mushroom Push Button 1-7/16" (38) momentary action. Provision for legend disc. D KSA-01 Black Mushroom Maintained Push Button 1-7/16" (38) maintained action. Turn to release. KSA-010 Red Emergency Stop Push Button 1-7/16" (38) maintained action. Turn to release. Actuator 0.7" (17) Double Push Button Actuator KSA-014 KSA-015 Red Emergency Stop Jumbo Push Button -13/16" (55) momentary action. (Not acceptable for ENELE/IE applications.) Red Emergency Stop Jumbo Push Button -13/16" (55) maintained action. Turn to release. ATUATOR DESRIPTION DIMENSIONS D Standard momentary push button 0.7" (18) 1.5" (38) Booted momentary push button 0.8" (0) 1.5" (38) Mushroom push button 1." (31) 1.5" (38) Key operated push button 1.7" (44) 1.5" (38) Key operated switch 1.7" (44) 1.5" (38) Mushroom E-Stop push button, key released 1.8" (46) 1.5" (38) Small E-Stop red push button 1." (31) 1.5" (38) Large E-Stop red push button 1." (31)." (55) KSA-009 ADDITIONAL PUSH BUTTON ATUATORS KSA-007 KSA KSA-008- KSA KSA-308 KSA-03 Keyed Red Emergency Stop Push Button 1-7/16" (38) maintained action. Key to release from maintained position. Key Operated Momentary Push Button Key removable in un-pressed position only. Position Keyed Switch Maintained Action Key removable, OFF-ON Key removable, OFF Key removable, ON 3 Position Keyed Switch. Maintained Action Key removable, all positions Double Momentary Push Button Supplied with Green Start and Red Stop Legend Discs *For other legend disks, see page 15.

11 R 10 S SERIES ONTROLS ONTAT BLOKS/ROTARY ATUATORS ontact Block Rotary Actuator System ertifications Apply FEATURES-SPEIFIATIONS Features ontact blocks are available in two versions 1N.. 1N.O. Explosion protected, DIN-like rail mounted block; NEMA A600 rated The single normally open or normally closed blocks can be combined to create other combinations Rotary actuators are for use with KSB Series contact blocks 1.6" (41) 1.9" (48) ONTAT BLOKS KSB-N 1.7" (43) 0.6" (14).0" (51) 1.9" (49) ontact Block, Single ONTAT SYMBOLS IE NEMA DESRIPTION ontact block 1 Normally closed (1N..) HAND OFF AUTO 1.5" (38) 1.6" (40) Rotary Actuator 1.8" (45) KSB-NO TEHNIAL DATA ONTAT BLOKS RATED VOLTAGE ONTINUOUS URRENT TERMINALS MEHANIAL LIFE ELETRIAL LIFE 600 VA 10A 10A NE/E ontact block 1 Normally open (1N.O.) 500 VA 6A 6A > 10 6 operations > 10 6 operations IE ROTARY ATUATORS POSITION KSA-76-R KSA-76-T 3 POSITION KSA-76-RR KSA-76-RT KSA-76-TR KSA-76-TT DESRIPTION Selector switch handle position maintained Selector switch handle position spring return from right Selector switch handle 3 position maintained* Selector switch handle 3 position spring return to center from right Selector switch handle 3 position spring return to center from left Selector switch handle 3 position spring return to center from left and right * Use () KSB-NO for standard hand-off-auto applications.

12 R S SERIES ONTROLS PILOT LIGHTS/ILLUMINATED PUSH BUTTONS 11 LED Unit LED Pilot LIght and ontact Blocks KSPLB Pilot LIght Illuminated Push Button KSIPA Actuator System ertifications Apply FEATURES-SPEIFIATIONS LED PILOT LIGHTS Features LED Pilot Lights accommodate any voltage from 1 to 50 volts, A or D High intensity LED s provide superior illumination levels that are easily viewable in direct sunlight from the front or side Long life and low temperature makes these units ideal for hazardous location applications Illuminated push buttons utilize KSB contact blocks 1NO+1N and LED pilot lights combined under a single operator to create an illuminated (also called push-to-test) push button By wiring components of the illuminated push button appropriately, different switching and indicating functions can be achieved LED LAMP UNIT BEZEL KSLU-R KSLU-G KSLU-A KSLU-B KSLU-W KSPLB-R KSPLB-G KSPLB-A KSPLB-B KSPLB-W TEHNIAL DATA-PILOT LIGHTS Rated Voltage Frequency Rated urrent Rated Power Electrical Life Terminals OLOR Red Green Amber Blue White ILLUMINATED PUSH BUTTON (ATUATOR ONLY) LED PILOT LIGHT AND ONTAT BLOKS MUST BE ORDERED SEPARATELY ATUATOR (MOMENTARY ONTAT) KSIPA-S 1V-15%...54V+6% D - 60 Hz Max. 15mA IE Max. 0.5 Watts 100,000 hours (11 years).5mm (1 AWG) SYMBOLS NEMA Includes red, green, amber, blue and white lenses 1.5" (38) 0.7" (17) 1.7" (43).6" (66) ø1.5" (ø 38) 0.6" (14).1" (53) 0.7" (17) LED Pilot Light Pilot Light Bezel Illuminated Push Button Actuator

13 R 1 S SERIES ONTROLS ONTROL SWITH HANDLES ontrol Switch Small Handle Small Lockable Handle Large Lockable Handle System ertifications Apply FEATURES-SPEIFIATIONS Features ontrol switches are rail mountable via a supplied adapter plate ontrol switch bodies are made from polyester and designed to safely contain the pressure generated by an internal explosion Switches are available in hundreds of different contact configurations Handles can be supplied with legend plates. See page 15 ontrol Switch onfiguration Selection Information Selector switch specification example: KSS-038 The illustrations to the right show that there are three positions to which the handle can be turned - 45 left position, 90 center position and 135 right position. The first contact, designated by terminal numbers 13-14, is open when the handle is in the left position (white box). It is also open at the center position (90 ) and closes on the way between center and right. It is closed in the 135 right position (black box). The second contact, designated by terminal numbers 3-4 is open at 45 (white box) and closes on the way between 45 and 90. At 90 it is closed (black box), at 135 it remains closed (black box). The terminal numbers are marked on the switch block. Selection charts for pole and 4 pole control switches appear on following pages. Other contact configurations available upon request. ONTROL SWITH HANDLES KSRA-73 KSRA-734 KSRA-731* * Specify legend with order. TEHNIAL DATA ONTROL SWITHES NE/E IE Rated Voltage 600V 690VA Rated urrent 10A 16A Mechanical Life > 10 5 Operations Electrical Life > 10 5 Operations Terminals 1AWG.5mm MAKE BREAK DIAGRAM º 135º 90º º 90º 135º ONTAT ARRANGEMENT Note: The arrow denotes spring return from right to center. The contacts have been drawn in the 45 position. This is indicated by the solid 45 line. 1.6" (41) HAND OFF AUTO 1.6" (40) 18" SWITH ATALOG NUMBER KSS " (41) HAND OFF AUTO Small rotary actuator. DESRIPTION Lockable, one position. Small rotary actuator. Lockable. Large rotary actuator. 1.9" (49).5" (64) 1.5" (38) 1.5" (38) KSRA-731 KSRA-73 KSRA-734

14 R S SERIES ONTROLS ONTROL SWITHES 13 ontrol Switch System ertifications Apply FEATURES-SPEIFIATIONS ONTROLS SWITHES 1.87" (47.5).4" (60.6).6" (65) 0.9" () 1.77" (45) ø 0.08" x.06" ø ( x 16) 1.9" (48) 1.77" (45) 0.18" (4.5) 0.18" (4.5) ø 0.18" ø (4.5) 1.9" (48) KSS Pole ontrol Switch 1.9" (48).4" (61).7" (68) KSS 4 Pole ontrol Switch.6" (66).9' (73) POLES/POSITIONS ONTAT SEQUENE ONTAT ARRANGEMENTS KSS-00 KSS-005 KSS-016 KSS-07 KSS-038 KSS-040 KSS-101 KSS-1051 KSS-1061 KSS-1101 KSS-1191 KSS-191 / / / /3 /3 /3 4/ 4/ 4/ 4/4 4/3 4/ NOTE: 4 pole ontrol Switches require installation in deep housing such as SF73, SF84, SF

15 R 14 S SERIES ONTROLS AMMETERS/POTENTIOMETERS Ammeter with Bezel/Window Potentiometer Actuator for Potentiometer System ertifications Apply FEATURES-SPEIFIATIONS AMMETERS (INLUDES BEZEL) Features Ammeters are used to measure the current of a motor supply circuit in a potentially explosive atmosphere Available in both direct and indirect read versions (current transformer not included) with a slide in scale to accommodate any amperage scale required Iron core movement with accuracy of ±.5% over the full range Red pointer can be manually adjusted to compare actual value with the set value Potentiometers function as a variable resistor, and can be used to adjust resistance in a control circuit TEHNIAL DATA AMMETERS NE/E IE Rated Insulated Voltage 600V 690V Movement Iron ore Power onsumption 0.W max. Frequency Hz (D available) Accuracy.5% of full range TEHNIAL DATA POTENTIOMETERS Rated Power Watt Voltage Limit 450V Resistance Values 100 Ohms to 4.7M Ohms haracteristics Linear Resistance Tolerance ± 30% Resistor Material arbon omposition Adjustment Scale 70 Degrees Terminals 1 AWG (.5 mm ) KSM-AD-004 KSM-AD-061 KSM-AD-001 KSM-AD-0048 KSM-AD-100 KSM-AD-1530 KSM-A1- KSM-A5- SALE ODES 0015=0-1/5 010=0-/10 51=0-.5/ =0-5/5 KSW-740 TYPE Direct read (x overload) Direct read (x overload) Direct read (x overload) Direct read (x overload) Direct read (x overload) Direct read (x overload) Indirect read (for current transformer) Indirect read (for current transformer) 1050=0-10/ =0-15/75 010=0-0/ =0-30/ =0-40/00 505=0-50/ =0-75/375 Replacement bezel/window POTENTIOMETERS UL PENDING RESISTANE VALUES IN OHMS KSPOT- 01=100Ω 09=47KΩ 0=0Ω 10=100KΩ 03=470Ω 11=0KΩ 04=1KΩ 1=470KΩ 05=.KΩ 13=1MΩ 06=4.7KΩ 14=.MΩ 07=10KΩ 15=4.7MΩ 08=KΩ ATUATOR FOR POTENTIOMETERS WITH DIAL SALE KSA-P6 0-6 KSA-P KSA-P " (3) MEASURING RANGE 0-0./0.4A 0-0.6/0.1A 0-1/ 0-4/8 0-10/0 0-15/30 1A Secondary, x or 5x Overload 5A Secondary, x or 5x Overload 1005=0-100/ =0-150/ =0-00/ " (48).6" (57.5).4" (60) KSM Ammeter 501=0-50/ =0-300/ =0-600/ " (9) (45) 0.5" (1).38" (60.5) 1.5" (38) Potentiometer Actuator 1.8" (46).5" (64) 0.5" (1) Ammeter Bezel/Window

16 S SERIES ONTROLS LEGEND DISKS & PLATES, ID LABELS 15 Quick ID Kit Push Button Legend Disks Small ontrol Switch Legend Plates Large Switch Handle Insert Legend Station ID Tag FEATURES-SPEIFIATIONS P USH BUTTON LEGEND DISKS INSERT TYPE SMALL ONTROL SWITH LEGEND PLATES DESRIPTION DESRIPTION KSL-140 KSL-130 KSL-10 KSL-110 KSL-100 KSL-090 KSL-870 KSL-880 KSL-900 KSL-90 blue yellow red green white Black Red STOP Green START Red OFF Black ON KSL KSL KSL KSL KSL KSL KSL-0850 KSL-696* KSL-03959** Hand-O-Auto Off-On O-l l-ll l-o-l O-l-ll O-[]-ll -1 line - lines KSL-830 KSL-840 KSL-80 Green l Green ll Red O INSERT TYPE LEGENDS FOR LARGE SWITH HANDLE DESRIPTION KSL-80 KSL-00 KSL-040 KSL-070 Red (lockwise arrow) Black UP Black DOWN Black RUN KSL KSL-850 KSL-3856* Hand-O-Auto Off-On KSL-060 KSL-050 KSL-990 Black SLOW Black FAST Black LOSE IDENTIFIATION LABELS DESRIPTION KSL-970 KSL-960 KSL-940 KSL-930 KSL-950 KSL-080 Black OPEN Black AUTO Black RIGHT Black LEFT Black HAND Blue RESET SF-IDENT KSL-1687* * Specify engraving with order. SF ontrol Station Quick Identification Kit (permits insertion of customer label) Station Identification Tag provides for up to lines, 14 characters per line (specify with order)

17 16 S SERIES ONTROLS WIRING ENTRY & AESSORIES onduit Hub Assembly Internal Brass Plate able Gland Drain/Breather Button Actuator Wrench Terminal Block Approved FEATURES-SPEIFIATIONS ONDUIT & ABLE ENTRY AESSORIES ONDUIT HUB ASSEMBLIES FOR S SERIES (FRP) HOUSINGS DESRIPTION KSH-00F 3/4" NPT fixed conduit hub assembly (hub, brass plate and sealing washer) ONDUIT HUB ASSEMBLIES FOR S SERIES (METAL) HOUSINGS KSP-733 button (to blank operator opening) KSH-00M 3/4" NPT fixed conduit hub assembly (hub, locknut and sealing washer) KSBP-M0 KSBP-M5 KSBP-001 KSBP-00 KSH-00 INDIVIDUAL OMPONENTS Internal brass plate (M0) Internal brass plate (M5) Internal brass plate (1/ NPT) Internal brass plate (3/4 NPT) Fixed hub for 3/4 NPT conduit for M5 plate KSW-305 KSTB-1 Actuator wrench Terminal block with 8 terminals GEA-NA-80M5 KSBF-M5 Nylon cable gland (gray) (M5) 9-13mm cable range Drain/breather fitting LK01 Momentary PB lockout LK0 Momentary PB exclusion LK03 Small mushroom PB guard LK01 Installed LK10 Small mushroom lockout LK11 Small mushroom pin & chain lockout LK0 Small mushroom exclusion LK10 Installed LK3 Double push button lockout

18 R P SERIES ONTROLS ONTROL PANELS 17 lass I, Div., Groups A,B,,D lass l, Zones 1 &, Groups II, llb, lla lass II, Div. 1 &, Groups E,F,G1 lass III NEMA 3, 4, 4x (A)Ex de II T6 IP66 FRP Size 08 Panel Stainless Steel Size 08 Panel Requires factory assembly FEATURES-SPEIFIATIONS Applications Hazardous and corrosive environments such as refineries, chemical plants, water treatment and bio gas plants, and wherever a combustible gas-air mixture or combustible dust may occur Many different combinations of explosion protected electrical devices and wiring entries can be configured to suit any application Features Electrical devices Ammeters, circuit breakers, disconnect and control switches, pilot lights, push buttons (momentary, maintained and illuminated), and more can be accommodated Modular onstruction Multiple enclosures can be coupled together using sealing frames to allow direct wire entry between enclosures ustom wiring entries hoose between PV-coated conduit hubs, compression, metal clad or other cable glands approved for area classifications Device mounting Integral electrical devices snap to modified DIN rails or special mounting plates over hinges Factory or field installed Grounding and bonding Provisions provided ontact factory with application requirements 1SA ertified for lass II, Div. 1&, EFG. UL Listed for lass II, Div., FG. Modular Design Flange Plates and Sealing Frames allow for coupling of individual enclosures to create larger units.

19 R 18 P SERIES ONTROLS ONTROL PANELS lass I, Div., Groups A,B,,D lass l, Zones 1 &, Groups II, llb, lla lass II, Div. 1 &, Groups E,F,G1 lass III NEMA 3, 4, 4X (A)Ex de II T6 IP66 FRP Size 07 Panel FEATURES-SPEIFIATIONS Stainless Steel Size 06 Panel Requires factory assembly * Dependent on cable entry connector types TYPIAL PANEL ONFIGURATIONS Applications Designed for onspec control operators (featured on pages 9-14), these enclosures use explosion protected components and increased safety terminals. hoose a panel configuration number and specify type of operators required. Operators include: LED pilot lights Push buttons Illuminated push buttons ontrol switches Ammeters Potentiometers Terminal blocks Wiring entry options include conduit hubs, compression, metal clad or other cable glands. See pages 0 and 1 for enclosure dimensions. PF031D010 PF041A00 PB041A00 PF41A030 PF031D001 PF041A001 PB041A001 FRP FRP Stainless Steel FRP Logic Example PF051D040 PB051D040 PF051D00 PB051D00 PF051D011 PB051D011 FRP Stainless Steel P F 06 1 A 03 O T onspec Panel Encl. Material Encl. Size Encl. Depth Encl. Side Down # Device Openings # Ammeter Openings Terminal Rail PF061A060 PF061A03OT PF061A031 PB061A060 PB061A03OT PB061A031 1SA ertified for lass II, Div. 1&, EFG. UL LIsted for lass II, Div., FG. FRP Stainless Steel

20 R P SERIES ONTROLS ONTROL PANELS 19 lass I, Div., Groups A,B,,D lass l, Zones 1 &, Groups II, llb, lla lass II, Div. 1 &, Groups E,F,G1 lass III NEMA 3, 4, 4X ENELE-EEx ed II T6 IP66* FRP Size 08 Panel FEATURES-SPEIFIATIONS Stainless Steel Size 08 Panel Requires factory assembly * Dependent on cable entry connector types TYPIAL PANEL ONFIGURATIONS PF071D10 PB071D10 PF071A06OT PB071A06OT PF071A04 PB071A04 FRP Stainless Steel PF081D40 PB081D40 PF081D10T PB081D10T PF081D13 PB081D13 FRP Stainless Steel PF091A40 PF091A360T PF091A300TT PF091D168TT FRP PB091A40 PB091A360T PB091A300TT PB091D168TT Stainless Steel 1SA ertified for lass II, Div. 1&, EFG. UL LIsted for lass II, Div., FG.

21 0 P SERIES ONTROLS FRP ENLOSURES DIMENSIONAL DATA.63" (16).35" (9).8" (7) A B.4" (60).8" D (7).8" D.63" (7) 3.7" (16).63" 3.6" (94) 4.6" (16) 3.6" (91) h 4.4" (91) h (118) (11.5) h A R6.35" (9) 6.7" (170) B.8" (7) 3.7" (94) 4.43" (11.5) A R6.8" (7) D 5.98" (15) 6.7" (170) B.35" (9) 4.65" (118).8" (7) Size 03 Size 04 Size " (5) 6.7" (170) A R6 B 6" (15) 6.7" (170) A R6 B 6" (15).63" (16) h.8" D.35" (7) (9) 6.9" (175).8" (7).63" (16) h.8" (7) D 11.4" (88.5) Size 06 Size 07.35" (9) 13.4" (340.5).8" (7).8" (7).35" (9) 13.4" (340.5).8" (7) R6 6.7" (170) A R6 B 4.65" (118) A B 11.4" (88.5).63" (16) h 1.7" (3.5) D Size S7 11.4".35" (88.5) (9).8" (7).8" (7).35" (9).63" (16) h D 1.7" (3.5) 13.4" (340.5) Size 08.8" (7) R6 A B 1.7" (3.5) 13.4" (340.5) AVAILABLE ENLOSURE DEPTHS.63" (16) h 11.4" (88.5) 6.8" (681.5) D Size 09.07" (5.5) DEPTH ODE (h) ENLOSURE 3.6" 5." 5.9" 6.7" 7.5" 9" SIZE (91) (131) (150) (171) (190) (30) 03 x 04 x 05 x x 06 x x 07 x x x x S7 x x 08 x x x x x x 09 x x x x

22 P SERIES ONTROLS STAINLESS STEEL ENLOSURE DIMENSIONAL DATA 1 h h Size 04 Size 05 h h Size 06 Size 07." (6)." (6).39" (10) 3.6" (91) h.39" (10) h 3.6" (91).8" (7).8" (7) 15.6" (396) 15.6" (396) A B 14.17" (360) A B 14.17" (360) 16." (41) 16. (41 D 1.6" (30) Size " (360).98" (5) " " 0) 7" (687) D 8.6" (77) Size 09.98" (5) AVAILABLE ENLOSURE DEPTHS DEPTH ODE (h) ENLOSURE SIZE 3.6"(91) 5.9"(150) 7.5"(190) 9"(30) 04 x 05 x 06 x x 07 x x 08 x x x x 09 x x x

23 R FXS SERIES ONTROLS FATORY SEALED ONTROLS lass I, Div. 1 &, Groups,D lass I, Zones 1 &, Groups llb, lla lass II, Div. 1 &, Groups E,F,G lass Ill NEMA 3, 7(,D) 9(E,F,G) Listed - File E53360 ertified - File LR11714 See files for details or call Killark. FEATURES-SPEIFIATIONS Applications SEAL-X Series Factory Sealed push button stations, selector switches, pilot lights and tumbler switches are used to prevent the igniting of external hazardous atmospheres by the enclosed arcing devices in such areas as: Hazardous locations due to the presence of flammable gases or vapors, combustible dusts or easily ignitable fibers or flyings Installations at petroleum refineries, chemical and petrochemical plants and other processing or storage facilities where similar hazards exist Use in conjunction with magnetic starters or contactors for remote control of motors Features Elimination of external sealing requirements Lower installation cost NEMA 3 weatherproof olor coded wiring-more wiring space-easier field installation Stainless steel captive screws for cover assembly Ground boss for grounding in the splice box Device bodies and covers are cast copper-free aluminum alloy ast conduit hubs 1/", 3/4" and 1" either dead end or feed through standard in both single and two gang assemblies Push button, selector switches and pilot light bodies are copper-free aluminum Operating shaft in both push buttons and selector switches are stainless steel Miniature and standard size push buttons. (Miniature 3/4" overall diameter, standard 1 3/8" overall diameter) Factory Sealed devices eliminate the need for external sealing. The difference is the use of a sealing plate between the arcing device and the junction box. The sealing plate confines ignited gases, vapors, flames, or dust to the arcing device chamber, preventing them from traveling through the conduit system. Accurately ground flanges on both sides of the sealing plate provide flame-tight joints. Factory poured seals around the wiring pigtails insure safe sealing. (FXS Series) Electrical Rating Push button stations, selector switches 600 VA max. heavy duty. ONTAT BLOK RATINGS URRENT 10 VA 40 VA 480 VA 600 VA INRUSH BREAKING ARRYING D RATINGS (MAX. AMPS) URRENT 15 VD 50 VD INRUSH BREAKING ARRYING MODIFIATIONS SUFFIX NUMBER AL L GL RL MR LO LOP DESRIPTION Pilot light lens-amber Pilot light lens-clear Pilot light lens-green Pilot light lens-red Mushroom head- Push button (red) Push button LOKOUT1 Selector switch-padlock LOKOUT 1LOKOUT must be installed at the factory. LED lamps available. See page 37.

24 R FXB SERIES ONTROLS FATORY SEALED SPLIE BOXES/SEALING METHODS 3 lass I, Div. 1 &, Groups,D lass I, Zones 1 &, Groups llb, lla lass II, Div. I &, Groups E,F,G lass Ill NEMA 3, 7(,D) 9(E,F,G) Listed - File E53360 FXB- Dead End FXB-5 Feed Thru FXB-8 Double Gang Dead End FXB-11 Double Gang Feed Thru ertified- File LR11714 See files for details or call Killark. FEATURES-SPEIFIATIONS Splice Boxes The FXB Series of splice boxes are designed for use with the FXS and FXS Series of cover sub-assemblies. FXB BAK BOX SELETION AND DIMENSIONS DESRIPTION FXB-1 Single gang/dead-end FXB- Single gang/dead-end FXB-3 Single gang/dead-end FXB-4 Single gang/feed-thru FXB-5 Single gang/feed-thru FXB-6 Single gang/feed-thru FXB-7 Double gang/dead-end FXB-8 Double gang/dead-end FXB-9 Double gang/dead-end FXB-10 Double gang/feed-thru FXB-11 Double gang/feed-thru FXB-1 Double gang/feed-thru HUB EXTERNAL MOUNTING SIZE LENGTH WIDTH DEPTH VERTIAL HORIZONTAL 1/" 3/4" 1" 1/" 3/4" 1" 1/" 3/4" 1" 1/" 3/4" 1" 6-13/16" 6-13/16" 6-13/16" 6-13/16" 6-13/16" 6-13/16" 6-13/16" 6-13/16" /16" 6-13/16" /16" 3-11/16" 3-11/16" 3-11/16" 3-11/16" 3-11/16" 7-17/3" 7-17/3" 7-17/3" 7-17/3" 7-17/3" 7-17/3" 1-3/4" 1-3/4" 1-3/4" 1-3/4" 1-3/4" 1-3/4" 6-3/16" 6-3/16" 6-3/16" 6-3/16" 6-3/16" 6-3/16" 6-3/16" 6-3/16" 6-3/16" 6-3/16" 6-3/16" 6-3/16" -1/4" -1/4" -1/4" -1/4" -1/4" -1/4" -1/4" -1/4" -1/4" -1/4" -1/4" -1/4"

25 R 4 FXS SERIES ONTROLS FATORY SEALED OVER ASSEMBLIES lass I, Div. 1 &, Groups,D lass I, Zones 1 &, Groups llb, lla lass II, Div. I &, Groups E,F,G lass Ill NEMA 3, 7(,D) 9(E,F,G) Listed - File E53360 and/or E1379 Single Push Button Double Push Button Pilot Light ertified - File LR11714 See files for details or call Killark. FEATURES-SPEIFIATIONS FXS MOMENTARY ONTAT SINGLE PUSH BUTTON OVER WITH DEVIE OMPLETE UNITS (BOX & OVER) HUB SIZE DEAD-END FEED-THRU FXS-0B1 FXS-1B1 FXS-4B1 1/" FXS-B1 FXS-5B1 3/4" FXS-0B FXS-1B FXS-4B 1/" FXS-B FXS-5B 3/4" FXS-0B3 FXS-1B3 FXS-4B3 1/" FXS-B3 FXS-5B3 3/4" DIAGRAM BUTTON OLOR Green Red Black NAMEPLATE MARKING1 Start Stop Specify FXS MOMENTARY ONTAT DOUBLE PUSH BUTTON OMPLETE UNITS (BOX & OVER) OVER WITH DEVIE DEAD-END FEED-THRU HUB SIZE DIAGRAM BUTTON OLOR NAMEPLATE MARKING1 FXS-1B4 FXS-4B4 1/" FXS-0B4 FXS-B4 FXS-5B4 3/4" FXS-0B4-U FXS-1B4U FXS-4B4-U 1/" FXS-B4U FXS-5B4-U 3/4" FXS-0B5 FXS-1B5 FXS-4B5 1/" FXS-B5 FXS-5B5 3/4" FXS-0B7 FXS-1B7 FXS-4B7 1/" FXS-B7 FXS-5B7 3/4" Green/Red Green/Red Green/Green Black/Black Star/Stop Start/Stop Start/Stop Specify FXS PILOT LIGHT OMPLETE UNITS (BOX & OVER) OVER WITH DEVIE DEAD-END FEED-THRU FXS-0B4L FXS-0B4GL FXS-0B4RL FXS-1B4L FXS-4B4L 1/" FXS-B4L FXS-5B4L 3/4" FXS-1B4GL FXS-4B4GL 1/" FXS-B4GL FXS-5B4GL 3/4" FXS-1B4RL FXS-4B4RL 1/" FXS-B4RL FXS-5B4RL 3/4" HUB DIAGRAM VOLT LENS NAMEPLATE SIZE OLOR MARKING1 10V lear Specify 10V Green Specify 10V Red Specify 1For other than standard marking, refer to the special feature section of price list. Lens colors other than listed may be specified by changing lens color suffix. See modifications page. NOTE: Boxes and covers shipped separately. *For control stations with 1" conduit openings or for double gang assemblies, order cover with device and box as separate components.

26 R FXS SERIES ONTROLS FATORY SEALED ONTROL STATION OVER ASSEMBLIES 5 Double Pilot Lights Pilot Light Two Mini Push Buttons lass I, Div. 1 &, Groups,D lass l, Zones 1 &, Groups llb, IlA lass II, Div. I &, Groups E,F,G lass Ill NEMA 3, 7(,D) 9(E,F,G) Listed - File E53360 and /or E1379 Pilot Light Push Button Maintained Push Button ertified - File LR11714 See files for details or call Killark. FEATURES-SPEIFIATIONS FXS DOUBLE PILOT LIGHTS OVER WITH DEVIE OMPLETE UNITS (BOX & OVER) HUB DIAGRAM LAMP LENS NAMEPLATE SIZE VOLTS OLOR MARKING1 DEAD-END FEED-THRU FXS-0B30L FXS-1B30L FXS-4B30L 1/" FXS-B30L FXS-5B30L 3/4" 10V lear Specify FXS-0B30GL FXS-1B30GL FXS-4B30GL 1/" FXS-B30GL FXS-5B30GL 3/4" 10V Green Specify FXS-0B30RL FXS-1B30RL FXS-4B30RL 1/" FXS-B30RL FXS-5B30RL 3/4" 10V Red Specify FXS-0B30RL-GL FXS-1B30RL-GL FXS-4B30RL-GL 1/" FXS-B30RL-GL FXS-5B30RL-GL 3/4" 10V Red/Green Specify FXS MOMENTARY ONTAT PUSH BUTTON AND PILOT LIGHT OMPLETE UNITS (BOX & OVER) OVER WITH DEVIE DEAD-END FEED-THRU FXS-0B13- FXS-0B13-O FXS-0B13-U FXS-1B13- FXS-4B13-1/" FXS-B13- FXS-5B13-3/4" FXS-1B13-O FXS-4B13-O 1/" FXS-B13-O FXS-5B13-O 3/4" FXS-1B13-U FXS-4B13-U 1/" FXS-B13-U FXS-5B13-U 3/4" FXS MOMENTARY ONTAT MINI PUSH BUTTON AND 1 PILOT LIGHT OMPLETE UNITS (BOX & OVER) OVER WITH DEVIE DEAD-END FEED-THRU FXS-0A15 NAMEPLATE HUB DIAGRAM LAMP BUTTON LENS MARKING1 SIZE VOLTS OLOR OLOR BUTTON LENS FXS-1A15 FXS-4A15 1/" FXS-A15 FXS-5A15 3/4" 10 VA 10V 10V 10V Red Red Stop Specify Green Red Start Specify Black Red Specify Specify NAMEPLATE HUB DIAGRAM BUTTON LENS MARKING1 SIZE OLOR OLOR BUTTON LENS Red/Green Red Stop Start Specify FXS MAINTAINED ONTAT - PUSH/PULL MUSHROOM4 BUTTON OLOR GREEN RED BLAK ONTAT TYPE 1NO/1N 1NO/1N 1NO/1N OVER ASSEMBLY AT. # FXS-OMMG3 FXS-OMMR3 FXS-OMMK3 ATALOG # WITH LOKOUT # FXS-OMMR3-LOM NAMEPLATE MARKING 3 1For other than standard marking, refer to the special feature section of price list. Lens colors other than listed may be specified by changing lens color suffix. See modifications page. 3Three nameplates supplied (Start/Stop,, Emergency Stop) with FXS maintained push button. 4Operation-when push button is depressed and contacts activated, operator will remain in depressed position until pulled out to normal position. NOTE: Boxes and covers shipped separately. *For control stations with 1" conduit opening or for double gang assemblies, order cover with device and box as separate components.

27 R 6 FXS SERIES ONTROLS FATORY SEALED OVER ASSEMBLIES lass I, Div. 1 &, Groups,D lass I, Zones 1 &, Groups llb, lia lass II, Div. 1 &, Groups E,F,G lass Ill NEMA 3, 7(,D) 9(E,F,G) Listed - File E53360 and/or E1379 Selector Switch Key Selector Switch ertified - File LR11714 See files for details or call Killark. FEATURES-SPEIFIATIONS FXS TWO POSITION SELETOR SWITH MAINTAINED ONTAT1 STANDARD STANDARD KEYED KEYED OVER HUB OMPLETE UNITS OVER OMPLETE UNITS WITH SIZE (BOX & OVER) WITH (BOX & OVER) DEVIE DEAD-END FEED-THRU DEVIE DEAD-END FEED-THRU FXS-0SA1 1/" FXS-1SA1 FXS-4SA1 FXS-1KA1 FXS-4KA1 FXS-0KA1 FXS-0SA1 3/4" FXS-SA1 FXS-5SA1 FXS-KA1 FXS-5KA1 FXS-0SA5 1/" FXS-1SA5 FXS-4SA5 FXS-1KA5 FXS-4KA5 FXS-0KA5 FXS-0SA5 3/4" FXS-SA5 FXS-5SA5 FXS-KA5 FXS-5KA5 LEFT POSITION RIGHT POSITION LEFT RIGHT LEFT RIGHT ONTAT ONTAT ONTAT ONTAT FXS THREE POSITION SELETOR SWITH MAINTAINED ONTAT1 STANDARD STANDARD KEYED KEYED OVER HUB OMPLETE UNITS OVER OMPLETE UNITS WITH SIZE (BOX & OVER) WITH (BOX & OVER) DEVIE DEAD-END FEED-THRU DEVIE DEAD-END FEED-THRU FXS-0S34 1/" FXS-1S34 FXS-4S34 FXS-1K34 FXS-4K34 FXS-0K34 FXS-0S34 3/4" FXS-S34 FXS-5S34 FXS-K34 FXS-5K34 FXS-0S35 1/" FXS-1S35 FXS-4S35 FXS-1K35 FXS-4K35 FXS-0K35 FXS-0S35 3/4" FXS-S35 FXS-5S35 FXS-K35 FXS-5K35 LEFT POSITION ENTER POSITION RIGHT POSITION LEFT RIGHT LEFT RIGHT LEFT RIGHT ONTAT ONTAT ONTAT ONTAT ONTAT ONTAT FXS TWO POSITION SELETOR SWITH SPRING RETURNED1 STANDARD STANDARD KEYED KEYED OVER HUB OMPLETE UNITS OVER OMPLETE UNITS WITH SIZE (BOX & OVER) WITH (BOX & OVER) DEVIE DEAD-END FEED-THRU DEVIE DEAD-END FEED-THRU FXS-0SL3F 1/" FXS-1SL3F FXS-4SL3F FXS-1KL3FD FXS-4KL3FD FXS-OKL3FD FXS-0SL3F 3/4" FXS-SL3F FXS-5SL3F FXS-KL3FD FXS-5KL3FD LEFT POSITION RIGHT POSITION LEFT RIGHT LEFT RIGHT ONTAT ONTAT ONTAT ONTAT TYPE OPERATION Spring return to left from right Maintained in left 1 N.O. ontact 1 N.. ontact FXS THREE POSITION SELETOR SWITH SPRING RETURNED1 LEFT POSITION ENTER POSITION RIGHT POSITION STANDARD STANDARD KEYED KEYED OVER HUB OMPLETE UNITS OVER OMPLETE UNITS LEFT RIGHT LEFT RIGHT LEFT RIGHT WITH SIZE (BOX & OVER) WITH (BOX & OVER) ONTAT ONTAT ONTAT ONTAT ONTAT ONTAT DEVIE DEAD-END FEED-THRU DEVIE DEAD-END FEED-THRU FXS-0S3M6G 1/" FXS-1S3M6G FXS-4S3M6G FXS-1K3M6G3D FXS-4K3M6G3D FXS-OK3M6G3D FXS-0S3M6G 3/4" FXS-S3M6G FXS-5S3M6G FXS-K3M6G3D FXS-5K3M6G3D FXS-0S3L6G 1/" FXS-1S3L6G FXS-4S3L6G FXS-OK3L6G3D FXS-1K3L6G3D FXS-4K3L6G3D FXS-0S3L6G 3/4" FXS -S3L6G FXS-5S3L6G FXS-K3L6G3D FXS-5K3L6G3D FXS-0S3R6G 1/" FXS-1S3R6G FXS-4S3R6G FXS-OK3R6G3D FXS-1K3R6G3D FXS-4K3R6G3D FXS-0S3R6G 3/4" FXS-S3R6G FXS-5S3R6G FXS-K3R6G3D FXS-5K3R6G3D TYPE OPERATION Spring return to center from left or right Maintained in center N.O. ontacts TYPE OPERATION Spring return to center from right Maintained center and left N.O. ontacts TYPE OPERATION Spring return to center from left Maintained center and right N.O. ontacts 1Nameplates are double sided. For other than standard marking, refer to the special feature section of the price list. STANDARD NAMEPLATE MARKINGS POSITION or Off-On 3 POSITION or Hand-Off-Auto. Key operated selector switches are randomly keyed with keys removable in all positions. For keyed alike or key removable in other than all positions contact factory. For control stations with 1" conduit opening or for double gang assemblies, order cover with device and box as separate components.

28 R R FXS SERIES ONTROLS FATORY SEALED TUMBLER SWITHES AND GROUND FAULT INTERRUPTER 7 Tumbler Switches Ground Fault Interrupter For GFI Protection with receptacle, See page PR6 lass I, Div. I &, Groups,D lass l, Zones 1 &, Groups llb,lla lass II, Div. 1 &, Groups E,F,G lass Ill NEMA 3, 7(,D) 9(E,F,G) FEATURES-SPEIFIATIONS Applications FXS Tumbler Switches are suitable for applications where making, breaking or changing connections in an electrical circuit is required and where conditions of load do not exceed the switch ratings. ertified - File LR11714 See files for details or call Killark. Applications FXS Ground Fault Interrupters are designed to interrupt a circuit when a ground fault is detected on equipment which may be handled by personnel in hazardous locations. Features Test and Reset push buttons are provided on cover assembly. Unit should be tested monthly Includes new GFI to meet latest UL943 GFI standards revisions Exterior gasket provides NEMA 3 weatherproof protection Ground boss for grounding in the splice box olor coded wiring aptive cover bolts are made from stainless steel Electrical Rating GFI units are rated at 0A, 10 VA, 60HZ. lass A. 4-6 miliamp trip setting Trip Time-UL urve Listed - File E53360 and/or Ffile E10501 Listed - File E80595 ertified - File LR61895 See files for details or call Killark. FXS TUMBLER SWITHES OMPLETE UNIT HUB SWITH SWITH RATING OVER (BOX, OVER AND SWITH) SIZE STYLE 10/77 VA, 1Ø WITH SWITH DEAD-END FEED-THRU FXS-1 FXS-11 FXS-41 1/" FXS-1 FXS-51 3/4" 1-POLE 0 A FXS- FXS-1 FXS-4 1/" FXS- FXS-5 3/4" -POLE 0 A FXS-8 FXS-18 FXS-48 1/" FXS-8 FXS-58 3/4" 3-POLE 1 FXS-3 FXS-13 FXS-43 1/" 3-WAY/ FXS-3 FXS-53 3/4" SPDT (No off) 0 A FXS-5 FXS-15 FXS-45 1/" FXS-5 FXS-55 3/4" SPDT (enter off) 0 A FXS-6 FXS-16 FXS-46 1/" FXS-6 FXS-56 3/4" DPDT (No off) 0 A FXS-1D FXS-11D FXS-41D 1/" FXS-1D FXS-51D 3/4" 1-POLE 30 A FXS-D FXS-1D FXS-4D 1/" FXS-D FXS-5D 3/4" -POLE 30 A FXS-4 4-WAY 0 A 1Rated 15 amperes, 40/480 VA., 3Ø; 3HP-40 VA., 5 HP-480 VA. Horsepower rated 1 HP at 10 VA, HP at 40 VA. FXS GROUND FAULT INTERRUPTER OMPLETE UNIT OVER ASSEMBLY BAK BOX* FXS-GFI-100 FXS-GFIO3 FXB-1 FXS-GFI-00 FXS-GFIO3 FXB- FXS-GFI-300 FXS-GFIO3 FXB-3 FXS-GFI-110 FXS-GFIO3 FXB-4 FXS-GFI-10 FXS-GFIO3 FXB-5 FXS-GFI-310 FXS-GFIO3 FXB-6 DEAD END FEED THRU HUB SIZE For control stations with 1" conduit opening or for double gang assemblies, order cover with device and box as separate components. *Boxes and covers shipped separately. See page DE for additional ground fault control stations. FXS GROUND FAULT INTERRUPTER WITH NEON LAMP 1/" 3/4" 1" 1/" 3/4" 1" FOR OVER ASSEMBLY FXS-GFIO3PL * Order FXB back box as seperate item.

29 R 8 XS/XS/SWB SERIES ONTROLS ONTROL STATIONS EXTERNAL SEALING REQUIRED lass I, Div. 1 &, Groups,D lass l, Zones 1 &, Groups llb, IIA lass II, Div. 1 &, Groups E,F,G lass Ill NEMA 7(,D) 9(E,F,G) Listed - File E53360 ertified - File LR11714, LR1171 See files for details or call Killark. FEATURES-SPEIFIATIONS Applications Hazardous locations due to the presence of flammable gases or vapors, combustible dusts or easily ignitable fiber or flyings Installations at petroleum refineries, chemical and petrochemical plants and other processing or storage facilities where similar hazards exist Use in conjunction with magnetic starters or contactors for remote control of motors Features Device bodies and covers are cast copperfree Aluminum alloy and provide a wide assortment for custom assemblies ast conduit hubs 1/", 3/4" and 1" either dead end or feed thru standard in both single and two gang, SWB-1 thru SWB-1 device bodies SWB-13 thru SWB-38 are designed for custom drilled and tapped conduit openings on all four sides and the back Ground flange joint between bolted cover and box provide required flame path Push button, selector switches and pilot light operator bodies are copper-free aluminum Operating shaft in both push buttons and selector switches are stainless steel Open space between gangs for easy wiring from one cover to another Miniature and standard size push buttons. (Miniature 3/4" overall diameter, standard 1-3/8" overall diameter.) ontact blocks are rated heavy duty, 600 VA max Internal ground screw Electrical Rating Push button stations, selector switches heavy duty 600 VA max. Pilot lights 10 VA. XS Special Assemblies To order XS cover assemblies for use with multi-gang or 1" hub type SWB Series splice boxes, simply order as follows: Example: XS-0B1 over Assembly SWB-6 Splice box with 1" feed thru hubs Example: XS-0B1 over Assembly XS-0B4RL over Assembly SWB-1 Double gang splice box NOTE: Splice boxes and cover assemblies are packaged in separate cartons. ONTAT BLOK RATINGS URRENT 10 VA 40 VA 480 VA 600 VA INRUSH BREAKING ARRYING D RATINGS (MAX. AMPS) URRENT 15 VA 50 VA INRUSH BREAKING ARRYING MODIFIATIONS ATALOG SUFFIX AL L GL RL T T4 MR LO LOP SU1 DESRIPTION Pilot light lens-amber Pilot light lens-clear Pilot light lens-green Pilot light lens-red 1Pilot light transformer 0/110VA 1Pilot light transformer 440/110VA Mushroom head push button (red) Push button lockout Selector switch padlock-lockout Stainless steel cover screws 1 One transformer required for each pilot light. Deep device bodies required for all except single pilot light units when transformers are used. Push button lockout must be factory installed. LED lamps available. See page 37.

30 R SWB SERIES ONTROLS DEVIE FODIES FOR USE WITH XS/XS/XT OVER ASSEMBLIES 9 Dead End SWB Feed Thru SWB Dead End SWB Feed Thru SWB lass I, Div. 1 &, Groups,D lass l, Zones 1 &, Groups llb, IIA lass II, Div. 1 &, Groups E,F,G lass Ill NEMA 7(,D) 9(E,F,G) Listed - File E53360 SWB SWB-17 SWB-18 ertified - LR1171 See files for details or call Killark. FEATURES-SPEIFIATIONS SWB-19 SWB-0 SWB-1 SWB-3 S WB DEVIE BODIES AND DIMENSIONS ATALOG HUB EXTERNAL MOUNTING NUMBER SIZE LENGTH WIDTH DEPTH VERTIAL HORIZONTAL SWB-1 SWB- SWB-3 SWB-4 SWB-5 SWB-6 SWB-7 SWB-8 SWB-9 SWB-10 SWB-11 SWB-1 SWB-13 SWB-14 SWB-17 SWB-18 SWB-19 SWB-0 SWB-1 SWB-3 SWB-33 SWB-34 SWB-38 SWB-4 SWB-45 SWB-49 1/" 3/4" 1" 1/" 3/4" 1" 1/" 3/4" 1" 1/" 3/4" 1" 1 1 3/4" 3/4" 3/4" 5-7/8"(149) 5-7/8"(149) 5-7/8"(149) 5-7/8"(149) 5-7/8"(149) 5-7/8"(149) 5-7/8"(149) 5-7/8"(149) 5-7/8 (149) 5-7/8"(149) 5-7/8"(149) 5-7/8"(149) 5-1/4"(133) 5-1/4"(133) 10-3/8"(64) 5-1/4"(133) 5-1/4"(133) 5-1/4"(133) 5-1/4"(133) 1"(305) 1 (305) 1"(305) 17-1/8"(435) 5-1/4"(133) 5-1/4"(133) 5-1/4"(133) 3"(76) 3"(76) 3"(76) 3"(76) 3"(76) 3"(76) 6-1/"(165) 6-1/"(165) 6-1/"(165) 6-1/"(165) 6-1/"(165) 6-1/"(165) 3-5/8"(9) 3-5/8"(9) 3-5/8"(9) 7-1/8"(181) 10-5/8"(70) 14-1/8"(359) 17-5/8"(448) 10-5/8"(70) 14-1/8"(359) 17-3/4"(451) 17-3/4"(451) 3-5/8" (9) 3-5/8"(9) 3-5/8"(9) -1/4"(57) -1/4"(57) -1/4"(57) -1/4"(57) -1/4"(57) -1/4"(57) -1/4"(57) -1/4"(57) -1/4"(57) -1/4"(57) -1/4"(57) -1/4"(57) -1/"(64) 3-5/16"(84) -1/"(64) 3-5/16"(84) 3-5/16"(84) 3-5/16"(84) 3-5/16"(84) 3-5/16"(84) 3-5/16"(84) 3-5/16"(84) 3-5/16"(84) 3-5/16"(84) 3-5/16"(84) 3-5/16"(84) 5-3/8"(137) 5-3/8"(137) 5-3/8"(137) 5-3/8"(137) 5-3/8"(137) 5-3/8"(137) 5-3/8"(137) 5-3/8"(137) 5-3/8"(137) 5-3/8"(137) 5-3/8"(137) 5-3/8"(137) 6-1/8"(156) 6-1/8"(156) 11-3/8"(89) 6"(15) 6"(15) 6"(15) 6"(15) 11-1/8"(83) 11-3/16"(84) 11-5/16"(87) 11-5/16"(87) 6-1/8"(156) 6-1/8"(156) 6-1/8"(156) -3/8"(60) -3/8"(60) -3/8"(60) -3/8"(60) -3/8"(60) -3/8"(60) -1/"(64) -1/"(64) -1/"(64) -1/"(64) -1/"(64) -1/"(64) -3/8"(60) -3/8"(60) -1/8"(54) 5-3/4"(146) 9-3/16"(33) 1-11/16"(3) 16-3/16"(411) 9-3/16"(33) 1-3/4"(34) 16-1/4"(413) 16-1/4"(413) -3/8"(60) -3/8"(60) -3/8"(60) 1Maximum size drilled and tapped opening 1" Shallow device bodies. Maximum size drilled and tapped opening 1-1/" Deep device bodies. 3SWB-1 thru SWB-1 Boxes have cast in conduit hubs. Additional conduit openings can not be included. Use SWB or 18 for custom conduit requirements. See following page for custom conduit information. SWB-13 through SWB-38 boxes are blank without conduit openings and can be factory or field installed. See following page for custom conduit information. SWB-33 SWB-34 SWB-38 SWB-4 (3/4" Dead End) SWB-45 (3/4" Feed Thru) SWB-48 (Two 1/"on Bottom) SWB-49 (Two 3/4"on Bottom)

31 30 SWB SERIES ONTROLS ONDUIT OPENING DATA onduit Opening Location harts V 1 J P SWB X T 1 G L P SWB-17 V AE A E 1 J V 1 3 RPN R P N SWB-18 SWB-19 J V A BD E R QPO N SWB-0 J V A B D E A B D E A B D E A E A B D E X X G J X G X G V T L T L T L T R Q P O N R Q O N R Q P O N R P N N O P Q R SWB-1 SWB-3 SWB-33 SWB-34 SWB-38 G J L FEATURES-SPEIFIATIONS To specify conduit openings select the letter on these sketches which indicates the position desired. All conduit openings will be evenly spaced and located in the area indicated on the location chart. When they are to be more accurately located, submit a sketch with spacing dimensions. Specific conduit openings must be located dimensionally from box centerlines to conduit centerlines and from outside back surface of box to conduit centerline. Ordering Instructions: (1) Select the letter on location chart which indicates conduit opening position desired. () Select symbol number from chart which indicates conduit opening type and size. (3) ombine the conduit location letter, size and type number, and add as a suffix to SWB box catalog number. Example: SWB-18-1-J1-P1-V1 SYMBOL NUMBERS ONDUIT OPENINGS ONDUIT DRILLED SIZE AND TAPPED UNION4 1/" /4" 1 1" /4" /" 5 15 MINIMUM HUB ENTERS FOR DRILLED AND TAPPED AND UNION HUBS SIZE FORM 1/" 3/4" 1" 1-1/4" 1-1/" 1/" 1MIN 1-3/16"(46) 1/" PRE 1-3/8"(35) 1/" 3GU 1-5/8"(41) 3/4" 1MIN 1-3/8"(35) 1-1/"(38) 3/4" PRE 1-1/"(38) 1-5/8"(41) 3/4" 3GU 1-3/4"(44) 1-13/16"(46) 1" 1MIN 1-1/"(38) 1-3/4"(44) 1-13/16"(46) 1" PRE 1-3/4"(44) 1-7/8"(48) "(51) 1" 3GU 1-7/8"(48) "(51) -1/8"(54) 1-1/4" 1MIN 1-11/16"(43) 1-15/16"(49) -1/16"(5) -5/16"(59) 1-1/4" PRE 1-15/16"(49) -1/16"(5) -1/4"(57) -1/"(64) 1-1/4" 3GU -1/16"(5) -1/4"(57) -5/16"(59) -1/"(64) 1-1/" 1MIN 1-15/16"(49) -1/16"(5) -3/16"(56) -1/"(64) -5/8"(67) 1-1/" PRE -1/8"(54) -1/4"(57) -3/8"(60) -5/8"(67) -3/4"(70) 1-1/" 3GU -3/16"(56) -9/3"(58) 7/16"(11) -5/8"(67) -3/4"(70) Locknut Bushing onduit 1-1/8"(9) 1-3/8"(35) 1-11/16"(43) -3/16"(56) -7/16"(6) Locknut Bushing onduit 1"(5) 1-1/4"(3) 1-1/"(38) 1-7/8"(48) -1/8"(54) Locknut Bushing onduit 7/8"() 1-1/16"(7) 1-3/8"(35) 1-11/16"(43) 1-15/16"(49) 1Minimum spacing required to provide clearance over locknuts and bushings. Preferredmore liberal spacings between centers of conduits to be used whenever possible. 3GUspacing required for GU Series unions. 4Union hubs are supplied by using a drilled and tapped opening with GUM Series Union. onsult factory for special or additional conduit sizes, locations, and combinations required but not illustrated.

32 R XS SERIES ONTROLS OVER ASSEMBLIES ONTROL STATIONS 31 lass I, Div. 1 &, Groups,D lass I, Zones 1 &, Groups IIB, IIA lass II, Div. 1 &, Groups E,F,G lass Ill NEMA 7(,D) 9(E,F,G) Single Push Button Double Push Button Three Mini-Push Button Push-Pull Mushroom Maintained Push Button Listed - File E53360 ertified - File LR11714 See files for details or call Killark. FEATURES-SPEIFIATIONS XS MOMENTARY ONTAT SINGLE PUSH BUTTON OMPLETE UNITS (BOX & OVER) HUB DIAGRAM BUTTON NAMEPLATE OVER WITH DEVIE SIZE OLOR MARKING1 DEAD-END FEED-THRU XS-1B1 XS-4B1 1/" XS-0B1 Green Start XS-B1 XS-5B1 3/4" XS-0B XS-0B3 XS-1B XS-4B 1/" XS-B XS-5B 3/4" XS-1B3 XS-4B3 1/" XS-B3 XS-5B3 3/4" Red Black Stop Specify XS MOMENTARY ONTAT DOUBLE PUSH BUTTON OVER WITH DEVIE XS-0B4 XS-0B4-U XS-0B5 XS-0B7 OMPLETE UNITS (BOX & OVER) DEAD-END FEED-THRU XS-1B4 XS-4B4 1/" XS-B4 XS-5B4 3/4" XS-1B4-U XS-4B4-U 1/" XS-B4-U XS-5B4-U 3/4" XS-1B5 XS-4B5 1/" XS-B5 XS-5B5 3/4" XS-1B7 XS-4B7 1/" XS-B7 XS-5B7 3/4" HUB DIAGRAM BUTTON NAMEPLATE SIZE OLOR MARKING1 Green-Red Green-Red Green-Green Black-Black Start/Stop Start/Stop Start/Start Specify XS MOMENTARY ONTAT THREE MINI PUSH BUTTONS OVER WITH DEVIE XS-0A8 XS-0A9 OMPLETE UNITS (BOX & OVER) DEAD-END FEED-THRU HUB DIAGRAM BUTTON NAMEPLATE SIZE OLOR MARKING1 XS-1A8 XS-4A8 1/" Green-Red Start/Stop XS-A8 XS-5A8 3/4" Black Specify XS-1A9 XS-4A9 1/" Black Specify XS-A9 XS-5A9 3/4" 1 For other than standard marking, refer to the special feature section of price list. Lens colors other than listed may be specified by changing lens color suffix. See modifications page 8. For control stations with 1" conduit openings or for multi-gang assemblies, order cover with devices and box as separate components. XS MAINTAINED ONTAT PUSH PULL MUSHROOM PUSH BUTTON4 (OVER WITH DEVIE) DIAGRAM BUTTON OLOR NAMEPLATE MARKING XS-OMMG3 GREEN XS-OMMR3 RED 3 XS-OMMK3 BLAK 3 Three nameplates supplied (Start/Stop,, Emergency Stop) with XS maintained push button. 4 Operation - when push button is depressed and contact activated, operator will remain in depressed position until pulled out in normal position.

33 R 3 XS SERIES ONTROLS OVER ASSEMBLIES ONTROL STATIONS lass I, Div. 1 &, Groups,D lass I, Zones 1 &, Groups IIB, IIA lass II, Div. 1 &, Groups E,F,G lass Ill NEMA 7(,D) 9(E,F,G) Listed - File E53360 Pilot Light Double Pilot Light Pilot Light Push Button Pilot Light Two Mini Push Buttons ertified - File LR11714 See files for details or call Killark. FEATURES-SPEIFIATIONS XS PILOT LIGHT3 OMPLETE UNITS (BOX & OVER) HUB DIAGRAM LAMP LENS NAMEPLATE OVER WITH DEVIE SIZE VOLTS OLOR MARKING1 DEAD-END FEED-THRU XS-1B4L XS-4B4L 1/" XS-0B4L 10V lear Specify XS-B4L XS-5B4L 3/4" XS-0B4GL XS-0B4RL XS DOUBLE PILOT LIGHT4 OMPLETE UNITS (BOX & OVER) HUB DIAGRAM LAMP LENS NAMEPLATE OVER WITH DEVIE SIZE VOLTS OLOR MARKING1 DEAD-END FEED-THRU XS-1B30L XS-4B30L 1/" XS-0B30L 10V lear Specify XS-B30L XS-5B30L 3/4" XS-0B30GL XS-0B30RL XS-0B30RL-GL XS MOMENTARY ONTAT TWO MINI PUSH BUTTONS AND PILOT LIGHT4 NAMEPLATE OMPLETE UNITS (BOX & OVER) HUB DIAGRAM BUTTON LENS MARKING1 OVER WITH DEVIE SIZE OLOR OLOR DEAD-END FEED-THRU BUTTON LENS XS-0A15 XS-1B30GL XS-4B30GL 1/" XS-B30GL XS-5B30GL 3/4" XS-1B30RL XS-4B30RL 1/" XS-B30RL XS-5B30RL 3/4" XS-1B30RL-GL XS-4B30RL-GL 1/" XS-B30RL-GL XS-5B30RL-GL 3/4" XS MOMENTARY ONTAT PUSH BUTTON AND PILOT LIGHT4 OMPLETE UNITS (BOX & OVER) OVER WITH DEVIE DEAD-END FEED-THRU XS-0B13- XS-0B13-O XS-0B13-U XS-1B4GL XS-4B4GL 1/" XS-B4GL XS-5B4GL 3/4" XS-1B4RL XS-4B4RL 1/" XS-B4RL XS-5B4RL 3/4" XS-1B13- XS-4B13-1/" XS-B13- XS-5B13-3/4" XS-1B13-O XS-4B13-O 1/" XS-B13-O XS-5B13-O 3/4" XS-1B13-U XS-4B13-U 1/" XS-B13-U XS-5B13-U 3/4" 10V Green Specify 10V Red Specify 10V Green Specify 10V Red Specify 10V Red/Green Specify NAMEPLATE HUB DIAGRAM BUTTON LENS MARKING1 SIZE OLOR OLOR BUTTON LENS Red Red Stop Specify Green Red Start Specify Black Red Specify Specify XS-1A15 XS-4A15 1/" Red Stop Red XS-A15 XS-5A15 3/4" 10 VA Green Start 1 For other than standard marking, refer to the special feature section of price list. Lens color suffix listed in modifications page 8. Unless different lens colors are specified by proper suffix catalog number, red lens will be provided. 3 Pilot light transformers also listed in modifications. Add suffix to cover assembly catalog number. 4 Pilot light transformers will not fit in these assemblies. When transformer is desired, use SWB-14, indicating conduit openings required from chart on page 30 of this section. See page 8 for required transformer suffix. One transformer required for each lamp. For control stations with 1" conduit openings or for multi-gang assemblies, order cover and box as separate components. Specify

34 XS SERIES ONTROLS OVER ASSEMBLIES ONTROL STATIONS 33 lass I, Div. 1 &, Groups,D lass I, Zones 1 &, Groups IIB, IIA lass II, Div. 1 &, Groups E,F,G lass Ill NEMA 7 (,D) 9(E,F,G) Selector Switch Key Operated Listed - File E53360 ertified - File LR11714 See files for details or call Killark. FEATURES-SPEIFIATIONS XS TWO POSITION SELETOR SWITH (MAINTAINED) TWO POSITION DIAGRAM LEFT POSITION RIGHT POSITION HUB NAMEPLATE OVER WITH OMPLETE UNITS (BOX & OVER) SIZE LEFT RIGHT LEFT RIGHT MARKING 1 DEVIE DEAD-END FEED-THRU BLOKS BLOKS BLOKS BLOKS XS-1SA1 XS-4SA1 1/" XS-0SA1 OFF/ON XS-SA1 XS-5SA1 3/4" XS-0SA5 XS-4SA5 XS-45SA5 3/4" OFF/ON XS THREE POSITION SELETOR SWITH (MAINTAINED) THREE POSITION DIAGRAM HUB LEFT POSITION ENTER POSITION RIGHT POSITION NAMEPLATE OVER WITH OMPLETE UNITS (BOX & OVER) SIZE LEFT RIGHT LEFT RIGHT LEFT RIGHT MARKING 1 DEVIE DEAD-END FEED-THRU BLOKS BLOKS BLOKS BLOKS BLOKS BLOKS XS-1S34 XS-4S34 1/" XS-0S34 HOA XS-S34 XS-5S34 3/4" XS-0S35 XS-4S35 XS-45S35 3/4" HOA 1 For other than standard marking, refer to the special feature section of the price list. These sub-assemblies require deep style box SWB-14 or SWB-18 through SWB-49. For control stations with 1" conduit openings or for multi-gang assemblies, order cover with devices and box as separate components. XS TWO POSITION KEY OPERATED SELETOR SWITH (MAINTAINED) TWO POSITION DIAGRAM HUB LEFT POSITION RIGHT POSITION NAMEPLATE OVER WITH OMPLETE UNITS (BOX & OVER) SIZE LEFT RIGHT LEFT RIGHT MARKING1 DEVIE DEAD-END FEED-THRU BLOKS BLOKS BLOKS BLOKS XS-1KA1D XS-4KA1D 1/" XS-0KA1D OFF/ON XS-KA1D XS-5KA1D 3/4" XS-0KA5D XS-4KA5D XS-45KA5D 3/4" OFF/ON XS THREE POSITION KEY OPERATED SELETOR SWITH (MAINTAINED) THREE POSITION DIAGRAM HUB LEFT POSITION ENTER POSITION RIGHT POSITION NAMEPLATE OVER WITH OMPLETE UNITS (BOX & OVER) SIZE LEFT RIGHT LEFT RIGHT LEFT RIGHT MARKING1 DEVIE DEAD-END FEED-THRU BLOKS BLOKS BLOKS BLOKS BLOKS BLOKS XS-1K34D XS-4K34D 1/" XS-0K34D HOA XS-K34D XS-5K34D 3/4" XS-0K35D XS-4K35D XS-45K35D 3/4" HOA 1For other than standard marking, refer to the special feature section of the price list. These sub-assemblies require deep style box SWB-14 or SWB-18 through SWB-49. For control stations with 1" conduit openings or for multi-gang assemblies, order cover with devices and box as separate components.

35 34 XS SERIES ONTROLS OVER ASSEMBLIES ONTROL STATIONS lass I, Div. 1 &, Groups,D lass I, Zones 1 &, Groups IIB, IIA lass II, Div. 1 &, Groups E,F,G lass Ill NEMA 7 (,D) 9(E,F,G) Listed - File E53360 Selector Switch ertified - File LR11714 See files for details or call Killark. FEATURES-SPEIFIATIONS XS SPRING RETURN SELETOR SWITH Two Position Spring Return to Left OVER WITH DEVIE1 OMPLETE UNITS (BOX & OVER) DEAD-END FEED-THRU HUB SIZE LEFT BLOK TWO POSITION DIAGRAM LEFT POSITION RIGHT POSITION RIGHT BLOK LEFT BLOK RIGHT BLOK XS-0SL3F XS-4SL3F XS-45SL3F 3/4" XS SPRING RETURN SELETOR SWITH Three Position Spring Return to enter From Right or Left OVER WITH DEVIE1 OMPLETE UNITS (BOX & OVER) DEAD-END FEED-THRU HUB SIZE THREE POSITION DIAGRAM LEFT POSITION ENTER POSITION RIGHT POSITION LEFT BLOK RIGHT BLOK LEFT BLOK RIGHT BLOK LEFT BLOK RIGHT BLOK XS-0S3M6G XS-4S3M6G XS-45S3M6G 3/4" XS SPRING RETURN SELETOR SWITH Three Position Spring Return to enter From Right, Maintain in Left OVER WITH DEVIE1 OMPLETE UNITS (BOX & OVER) DEAD-END FEED-THRU HUB SIZE THREE POSITION DIAGRAM LEFT POSITION ENTER POSITION RIGHT POSITION LEFT BLOK RIGHT BLOK LEFT BLOK RIGHT BLOK LEFT BLOK RIGHT BLOK XS-0S3L6G XS-4S3L6G XS-45S3L6G 3/4" XS SPRING RETURN SELETOR SWITH Three Position Spring Return to enter From Left, Maintain in Right OVER WITH DEVIE1 OMPLETE UNITS (BOX & OVER) DEAD-END FEED-THRU HUB SIZE THREE POSITION DIAGRAM LEFT POSITION ENTER POSITION RIGHT POSITION LEFT BLOK RIGHT BLOK LEFT BLOK RIGHT BLOK LEFT BLOK RIGHT BLOK XS-0S3R6G XS-4S3R6G XS-45S3R6G 3/4" 1 All spring return assemblies must be installed on deep style box SWB-14 or SWB-18 through SWB-49. For control stations with 1" conduit openings or for multi-gang assemblies, order cover with devices and box as separate components.

36 XS SERIES ONTROLS OVER ASSEMBLIES ONTROL STATIONS 35 lass I, Div. 1 &, Groups,D lass I, Zones 1 &, Groups IIB, IIA lass II, Div. 1 &, Groups E,F,G lass Ill NEMA 7 (,D) 9(E,F,G) Listed - File E53360 Key Operated ertified - File LR11714 See files for details or call Killark. FEATURES-SPEIFIATIONS XS KEY OPERATED SPRING RETURN SELETOR SWITH1 Two Position Spring Return to Left OVER WITH DEVIE OMPLETE UNITS (BOX & OVER) DEAD-END FEED-THRU HUB SIZE LEFT BLOK TWO POSITION DIAGRAM LEFT POSITION RIGHT POSITION RIGHT BLOK LEFT BLOK RIGHT BLOK XS-0KL3FD XS-4KL3FD XS-45KL3FD 3/4" XS KEY OPERATED SPRING RETURN SELETOR SWITH1 Three Position Spring Return to enter From Right or Left OVER WITH DEVIE OMPLETE UNITS (BOX & OVER) DEAD-END FEED-THRU HUB SIZE XS-0K3M6G3D XS-4K3M6G3D XS-45K3M6G3D 3/4" THREE POSITION DIAGRAM LEFT POSITION ENTER POSITION RIGHT POSITION LEFT BLOK RIGHT BLOK LEFT BLOK RIGHT BLOK LEFT BLOK RIGHT BLOK XS KEY OPERATED SPRING RETURN SELETOR SWITH1 Three Position Spring Return to enter From Right, Maintain in Left OVER WITH DEVIE OMPLETE UNITS (BOX & OVER) DEAD-END FEED-THRU HUB SIZE THREE POSITION DIAGRAM LEFT POSITION ENTER POSITION RIGHT POSITION LEFT BLOK RIGHT BLOK LEFT BLOK RIGHT BLOK LEFT BLOK RIGHT BLOK XS-0K3L6G3D XS-4K3L6G3D XS-45K3L6G3D 3/4" XS KEY OPERATED SPRING RETURN SELETOR SWITH1 Three Position Spring Return to enter From Left, Maintain in Right OVER WITH DEVIE OMPLETE UNITS (BOX & OVER) DEAD-END FEED-THRU HUB SIZE THREE POSITION DIAGRAM LEFT POSITION ENTER POSITION RIGHT POSITION LEFT BLOK RIGHT BLOK LEFT BLOK RIGHT BLOK LEFT BLOK RIGHT BLOK XS-0K3R6G3D XS-4K3R6G3D XS-45K3R6G3D 3/4" 1 All key operators are furnished keyed different. If keyed alike is required substitute letter A for D at end of catalog number. Keys are removable in left position selectors and in center position for 3 position selectors. For key removable in all positions change in position to 0 and 3 in 3 position to 30. All spring return assemblies must be installed on deep style box SWB-14 or SWB-18 through SWB-49. For control stations with 1" conduit openings or for multi-gang assemblies, order cover with devices and box as separate components.

37 36 SEAL X/XS SERIES ONTROLS BLANK AESSORIES/REPLAEMENT PARTS X-10 over Standard Push Button (Mushroom) Miniature Push Button X BLANK AND SPEIAL OVERS AT. NO. DESRIPTION X-10 cover X-60 over with (1) 3/4" NPSM Hole1 X-64 over with () 3/4" NPSM Holes1 1 For G series short operators. When X-64 cover is used, one operator must be a pilot light due to electrical clearances. STANDARD PUSH BUTTON ASSEMBLY1 MINIATURE PUSH BUTTON ASSEMBLY (1-3/8 DIAMETER) (3/4 DIAMETER) RED GREEN BLAK RED GREEN BLAK SHROUD XO1BR XO1BG XO1BK XO1AR XO1AG XO1AK Full XO3BR XO3BG XO3BK XO3AR XO3AG XO3AK Half XO5BR Mushroom* *1-1/ diameter Pilot Light XS PILOT LIGHT OPERATOR ASSEMBLY1 RED GREEN LEAR AMBER SHROUD XO1BR XO1BG XO1B XO1BA Standard Standard Lockout Miniature Lockout Selector Lockout Hole Plug Dust/Weather ap GOM Lockout AESSORIES PUSH BUTTON1 SELETOR HOLE DUST/WEATHER AP DESRIPTION LOKOUT LOKOUT1 PLUG1 RED GREEN BLAK XLOB G0-567-LOK XOBP XDBR XDBG XDBB Standard operator XLOA XOAP Miniature operator 1 Replacement only by qualified person. Operator is staked into position at factory. Removal may damage operator or cover threads. GOMLOK LOKOUT FOR MAINTAINED PUSH BUTTON OVERS XS-OMMR3 FXS-OMMR3 XS REPLAEMENT BLANK NAMEPLATES XSNPPB XSNPPBM XSNPPL XSNPSS XSNPSS3 DESRIPTION XS/FXS full size (standard) push button XS/FXS miniature push button XS/FXS pilot light XS/FXS position selector switch XS/FXS 3 position selector switch

38 SEAL X/XS SERIES ONTROLS AESSORIES/REPLAEMENT PARTS 37 Lamps for assemblies shipped prior to 1/1/06 ontact Block STANDARD ONTAT BLOKS Incandescent Filament Lamp INANDESENT LAMP ANDELABRA SREW BASE VOLT OLOR B 10V A/D LEAR B 4V A/D LEAR GO-867-BJK GO-867-BJJ GO-867-BJH GO-867-BJE YOWE-OTB YOWE-OTD DESRIPTION 1 N.O. 1 N.. 1 N.O. Early make 1 N.. Late break ONTAT BLOKS FOR XS SERIES S ENDING WITH B4-U, B7, A8, OR A9. DESRIPTION 1 N.O. 1 N.. Lamps for assemblies shipped after 1/1/06 LED Lamp XS-FXS LED LAMPS VOLT OLOR XSLED-R VA Red XSLED-G VA Green XSLED-A VA Amber ONTAT BLOK FOR FXS SERIES ENDING WITH B-13U DESRIPTION GO-867-PTH (1) N.O. (1) N.. ONTAT BLOK FOR FXS SERIES ENDING WITH B4-U, B7, A5, 5 DESRIPTION GO-867-PT () N.O. () N.. Incandescent Filament Lamp LED Lamp XS-FXS LAMPS LAMP TYPE VOLTS A/D OLOR YOSY4MB Filament 4 lear YOSY10MB Filament 130 lear GOLED-A110 LED 110 Amber GOLED-G110 LED 110 Green GOLED-R110 LED 110 Red GOLED-A4 LED 4 Amber GOLED-G4 LED 4 Green GOLED-R4 LED 4 Red

39 38 XS SERIES ONTROLS TUMBLER SWITH lass I, Div. 1 &, Groups,D lass l, Zones 1 &, Groups llb, lla lass II, Div. 1 &, Groups E,F,G lass Ill NEMA 7(,D) 9(E,F,G) Listed - FILE E53360 ertified - File LR1171 XS-3 FM APPROVED File OP7A5.AE See files for details or call Killark. FEATURES-SPEIFIATIONS Applications Used where making, breaking, or changing connections in an electric circuit are required. Features XS Series are front lever rotary operated switch assemblies with standard provisions for padlocking in either ON or OFF position. The lever is connected to a threaded stainless steel shaft which passes through the cover. XS TUMBLER SWITH OVER OMPLETE UNITS HUB WITH WITHOUT (BOX, OVER AND SWITH) SIZE DEVIE DEVIE DEAD-END FEED-THRU XS-1 XNS-1 1/" XS-11 XS-41 3/4" XS-1 XS-51 XS- XNS- 1/" XS-1 XS-4 3/4" XS- XS-5 XS-8 XNS-8 1/" XS-18 XS-48 3/4" XS-8 XS-58 XS-3 XNS-3 1/" XS-13 XS-43 3/4" XS-3 XS-53 XS-5 XNS-5 1/" XS-15 XS-45 3/4" XS-5 XS-55 XS-6 XNS-6 1/" XS-16 XS-46 3/4" XS-6 XS-56 XS-7 XNS-7 1/" XS-17 XS-47 3/4" XS-7 XS-57 XS-1D XNS-1D 1/" XS-11D XS-41D 3/4" XS-1D XS-51D XS-D XNS-D 1/" XS-1D XS-4D 3/4" XS-D XS-5D XS-4 1-POLE -POLE SWITH STYLE 1 Rated 15 amperes, 40/480 VA., 3Ø: 3HP-40 VA., 5 HP-480 VA. Horsepower rated 1 HP at 10VA, HP at 40VA. 3-POLE 1 3-WAY/ SPDT No center off SPDT enter off DPDT No center off DPDT enter off 1-POLE -POLE 4-WAY SWITH RATING 10/77 VA, 1Ø 0A 0A 0A 0A 0A 0A 30A 30A 0A

40 XAL/XAS SERIES ONTROLS FIRE ALARM STATIONS 39 XAL Pull Ring FEATURES-SPEIFIATIONS XAS Break Glass lass I, Div. 1 &, Groups,D lass l, Zones 1 &, Groups llb, lla lass II, Div. 1 &, Groups E,F,G lass Ill NEMA 7(,D) 9(E,F,G) Applications Hazardous areas due to the presence of flammable gases or vapors, combustible dusts or easily ignitable fibers or flyings Installation at petroleum refineries, chemical and petrochemical plants, storage areas, and other processing facilities where hazardous substances are handled or stored Areas where emergency control of fire alarm or signal circuits is required Features Enclosure is made of copper free aluminum alloy onduit openings are 3/4" NPT feed through Red, textured powder epoxy paint finish is standard on box and cover and provides high visibility for alarm station XAL-458 has () normally open and () normally closed contacts. Bilingual nameplates included per SA requirement Internal ground screw is standard Operation XAL: The alarm station is activated by lifting the front cover and pulling down ring. This quick, easy to use two-step process prevents unintentional operation. Operator is reset by depressing shaft and returning plate to original position. XAL Series: Listed - File E50498 Listed - E69 ertified - File LR31085 Listed - alifornia State Fire Marshall # :100 XAL FIRE ALARM STATION ONTAT BLOK RATING XAS: Breaking glass with hammer provided activates alarm. Reset by replacing glass. Replacement glass catalog number YOKK Replacement hammer and chain KIT-3. XAS Series: Listed - File E50498 ertified - File LR31085 See files for details or call Killark. OPERATION TYPE ONTAT BLOKS XAL-53 Pull ring (1) NO/N XAL-458 Pull ring () NO/N XAS-53 Break glass (1) NO/N A D VOLTS ONTINUOUS ONTINUOUS MAKE BREAK MAKE VA VA ARRYING VOLTS ARRYING AMPERES AMPERES BREAK AMPERES AMPERES Dimensions XAL-53 Note: On XAL-458 the overall depth is 5-9/16 XAS-53

41 40 G SERIES ONTROLS USTOM ONTROL PANEL OPERATORS INTRODUTION lass I, Div. 1 &, Groups B,,D lass I, Zones 1 &, Groups llb, lla lass II, Div. 1 &, Groups E,F,G lass Ill NEMA 3, 4, 4X, 7(B,,D) 9(E,F,G) See Area lassification hart below FEATURES-SPEIFIATIONS Applications G Series custom control panel operators are designed for use in hazardous locations when installed in suitable enclosures such as B7E EXB, XB, XJB, DB, SWB and GS Series boxes and B7, Y7 Starter Enclosures. Features Operators are all aluminum except for certain movable parts which are stainless steel, all other parts such as screws are either stainless steel or plated steel Threaded bodies are all 3/4"-14 NPSM thread ontrol stations can be grouped into a single assembly thus reducing installation time and cost Junction boxes may be used to mount operators along with glass lens for viewing internally mounted meters. Additional relays, timers, terminal blocks, or other equipment may also be internally mounted to provide a single centralized control unit. ustom operators other than standard assemblies listed may be ordered by proper catalog number from custom operator ordering system pages 50 & 51 Electrical Rating Push button stations, selector switches Heavy duty 600 VA max. Pilot lights 10 VA. Dimensions See Dimensional information for G Series operators on page 5. Recommended Operator Selection Short Style DB/SWB/GS Enclosures. Assemblies with wall thickness up to 1/" thick. Long Style All B7E XB/XJB Enclosures. EXB except larger sizes. Assemblies with wall thickness up to 1-1/" thick. Extended Style EXB larger size enclosures. 16" x 4", 18" x 18", 18" x 4", 18" x 36", 0" x 36", 4" x 4", 4" x 36". Assemblies with wall thickness up to -1/" thick. ONTAT BLOK RATINGS URRENT 10 VA 40 VA 480 VA 600 VA 15 VD 50 VD Inrush Breaking arrying Note: ontact blocks can be stacked four deep maximum. AREA LASSIFIATION HART FOR OPERATORS GO14 GO4 GO54 GO64 GO74 GO83 GO104 GO144 GO154 GO16 GO17 GO18 GO19 GO1 GO GO3 GO5 GO6 GO7 GO8 GO30 GO34 GO35 GO363 GO373 GO383 GO393 GO401 GO50 G051 GO56 Killark long and extended push buttons, selector switches, reset and potentiometer operators are ENELE/ATEX EExd IIB+H when installed in series EXB*EN and GR*EN enclosures. For pilot lights and illuminated push buttons in ENELE/ATEX applications see page 43. GO57 GO58 GO59 GO1133 GO1143 GO133 GO134 GOB34 GOB44 GOL14 GOL4 GOL34 GOL44 GOL54 GOL64 GOL74 GOL83 GOL144 GOL154 GOL363 GOL374 GOL383 GOL393 GOL1133 GOL1143 GOLRST4 GOM15 GOR114 GORST4 GO11388 GO lass II Div. 1 & Group EFG NEMA 9EFG lass I Div. 1 & Group D, lass II Div. 1 & Group EFG, lass III NEMA 7D, 9EFG 3 lass I Div. 1 & Group BD, lass II Div. 1 & Group EFG, lass III NEMA 3, 4, 7BD, 9EFG 4 lass I Div. 1 & Group BD, lass II Div. 1 & Group EFG, lass III NEMA 3, 4, 4X, 7BD, 9EFG 5 lass I Div. 1 & Group D, lass II Div. 1 & Group EFG, lass III NEMA 3, 4, 7D, 9EFG

42 G SERIES ONTROLS PUSH BUTTONS 41 Single Push Button Long Single Push Button Extended lass I, Div. 1 &, Groups B,,D4 lass I, Zones 1 &, Groups llb, lla lass II, Div. 1 &, Groups E,F,G lass Ill NEMA 3, 4, 4X, 7(B,,D) 9(E,F,G) See Area lassification hart page 40 for Details G Series Operator Maintained Double Push Button Listed - File E1379 ertified - File LR11714 See files for details or call Killark. FEATURES-SPEIFIATIONS G SINGLE PUSH BUTTON (MOMENTARY ONTAT) 1 SHORT4 LONG EXTENDED GO1-GZ1B GO1-GX1B N34 GOL1G1 GO1-KZ1 GO1-KX1 N34 GOL1K1 GO1-RZB GO1-RXB N34 GOL1R GO1-KZ GO1-KX N34 GOL1K GO1-GZ3 GO1-GX3 N34 GOL1G3 GO1-RZ3 GO1-RX3 N34 GOL1R3 GO1-KZ3 GO1-KX3 N34 GOL1K3 GO1-GZ0 GO1-GX0 N34 GOL1G GO1-RZ0 GO1-RX0 N34 GOL1R GO1-KZ0 GO1-KX0 N34 GOL1K OLOR Green Black Red Black Green Red Black Green Red Black ONTAT TYPE3 None NAMEPLATE MARKING Start or Stop Reset or Start or Stop Reset or Reset or Reset or Reset or Reset or Reset or Reset or G SINGLE PUSH BUTTON (MAINTAINED ONTAT) MUSHROOM HEAD PUSH - PULL OPERATION GOM1-GM3 GOM1-GM3 N34 GOML1G3 Green GOM1-RM3 GOM1-RM3 N34 GOML1R3 Red GOM1-KM3 GOM1-KM3 N34 GOML1K3 Black GOM1-GM0 GOM1-GM0 N34 GOML1G Green GOM1-RM0 GOM1-RM0 N34 GOML1R Red GOM1-KM0 GOM1-KM0 N34 GOML1K Black None G DOUBLE PUSH BUTTON (MOMENTARY ONTAT) GO-GR1D GO-KK1D GO-GR33D GO-KK33D GO-GR00D GO-KK00D G0-GR1D N34 G0-KK1D N34 G0-GR33D N34 G0-KK33D N34 G0-GR00D N34 G0-KK00D N34 GOLGR1 GOLKK1 GOLGR33 GOLKK33 GOLGR GOLKK Green/Red Black/Black Green/Red Black/Black Green/Red Black/Black None Start/Stop or Start/Stop or Start/Stop or Start/Stop or Start/Stop or Start/Stop or G DOUBLE PUSH BUTTON (MAINTAINED ONTAT)5 GOR11-GR6D N34 Green/Red Start/Stop or GOR11-GR7D N34 GOR11-GR8D N34 Green/Red Green/Red Start/Stop or Start/Stop or GOR11-GR0D N34 Green/Red None Start/Stop or 1 Refer to catalog page 40 to select proper operator for enclosure, pages 48 & 49 for accessories, page 40 for complete details on Area lassification of operators, page 5 for Dimensional information. Nameplates are double sided. 3 ontact Blocks are shown in their normal position. 4 Short style operators are suitable for lass l Group & D, lass ll Group E,F,G only. 5 When pressed, the green button will remain in a depressed position. Pressing red button releases green from the depressed position.

43 4 GS SERIES ONTROLS PILOT LIGHTS lass I, Div. 1 &, Groups B,,D4 lass I, Zones 1 &, Groups llb, lla lass II, Div. 1 &, Groups E,F,G lass Ill NEMA 3, 4, 4X, 7(B,,D) 9(E,F,G) See Area lassification hart page 40 for Details Listed - File E1379 Pilot Light Illuminated Button ertified - File LR11714 See files for details or call Killark. FEATURES-SPEIFIATIONS G PILOT LIGHTS 1 SHORT4 LONG EXTENDED OLOR ONTAT TYPE3 NAMEPLATE MARKING GO3-A3 GOB3-A3 N34 GOL3A Amber GO3-B3 GOB3-B3 N34 GOL3B Blue GO3-3 GO3-F3 GOB3-3 N34 GOB3-F3 N34 GOL3 GOL3F lear Frosted Volts Full Volts GO3-G3 GOB3-G3 N34 GOL3G Green GO3-R3 GOB3-R3 N34 GOL3R Red G PILOT LIGHTS WITH LED 110 VOLT LAMPS GOB3-A3 N34 LED GOB3-G3 N34 LED GOB3-R3 N34 LED GOL3A LED GOL3G LED GOL3R LED Amber Green Red Volts Full Volts (LED) G ILLUMINATED BUTTON OR PUSH TO TEST PILOT LIGHT GOB4-A33 N34 GOB4-B33 N34 GOB4-33 N34 GOL4A3 GOL4B3 GOL43 Amber Blue lear Volts Full Volts GOB4-F33 N34 GOB4-G33 N34 GOB4-R33 N34 GOL4F3 GOL4G3 GOL4R3 Frosted Green Red GOB4-A30 N34 GOL4A Amber GOB4-B30 N34 GOB4-30 N34 GOB4-F30 N34 GOB4-G30 N34 GOL4B GOL4 GOL4F GOL4G Blue lear Frosted Green Volts No ontact Blocks GOB4-R30 N34 GOL4R Red G ILLUMINATED BUTTON OR PUSH TO TEST PILOT LIGHT WITH LED 110 VOLT LAMPS GOB4-A33 N34 LED GOB4-G33 N34 LED GOB4-R33 N34 LED GOB4-A30 N34 LED GOB4-G30 N34 LED GOB4-R30 N34 LED GOL4A3 LED GOL4G3 LED GOL4R3 LED GOL4A LED GOL4G LED GOL4R LED Amber Green Red Amber Green Red Volts Full Volts (LED) Volts (LED) No ontact Blocks 1Refer to catalog page 40 to select proper operator for enclosure, pages 48 & 49 for accessories, page 40 for com plete details on Area lassification of operators, page 5 for Dimensional information. Nameplates are double sided. 3ontact Blocks are shown in their normal position. 4Short style operators are suitable for lass l Group & D, lass ll Group E,F,G only.

44 G SERIES ONTROLS PILOT LIGHTS FOR ATEX/ENELE APPLIATIONS 43 lass I, Div. 1 &, Groups B,,D lass I, Zones 1 &, Groups llb+h, lla lass II, Div. 1 &, Groups E,F,G lass Ill NEMA 3, 4, 4X, 7(B,,D) 9(E,F,G) ATEX-EExd IIB + H Listed - File E1379 Pilot Light ATEX Illuminated Push Button ATEX ertified - File LR11714 PTB No. 03ATEX 103 U FEATURES-SPEIFIATIONS G PILOT LIGHTS LONG GOB3-A3 N34N GOB3-B3 N34N GOB3-3 N34N GOB3-F3 N34N GOB3-G3 N34N GOB3-R3 N34N 1 EXTENDED GOL3AN GOL3BN GOL3N GOL3FN GOL3GN GOL3RN OLOR Amber Blue lear Frosted Green Red ONTAT TYPE Volts Full Volts NAME PLATE MARKING G PILOT LIGHTS WITH LED 110 VOLT LAMPS GOB3-A3 N34LEDN GOB3-G3 N34LEDN GOB3-R3 N34LEDN GOL3ALEDN GOL3GLEDN GOL3RLEDN Amber Green Red Volts Full Volts (LED) G ILLUMINATED PUSH BUTTON OR PUSH TO TEST PILOT LIGHT GOB4-A33N34N GOB4-B33N34N GOB4-33N34N GOB4-F33N34N GOB4-G33N34N GOB4-R33N34N GOB4-A30N34N GOB4-B30N34N GOB4-30N34N GOB4-F30N34N GOB4-G30N34N GOB4-R30N34N GOL4A3N GOL4B3N GOL43N GOL4F3N GOL4G3N GOL4R3N GOL4A0N GOL4B0N GOL40N GOL4F0N GOL4G0N GOL4R0N Amber Blue lear Frosted Green Red Amber Blue lear Frosted Green Red Volts Full Volts Volts No ontact Blocks G ILLUMINATED PUSH BUTTON OR PUSH TO TEST PILOT LIGHT WITH LED 110 VOLT LAMPS GOB4-A33N34LEDN GOB4-G33N34LEDN GOB4-R33N34LEDN GOB4-A30N34LEDN GOB4-G30N34LEDN GOB4-R30N34LEDN GOL4A3LEDN GOL4G3LEDN GOL4R3LEDN GOL4A0LEDN GOL4G0LEDN GOL4R0LEDN Amber Green Red Amber Green Red Volts Full Volts (LED) Volts (LED) No ontact Blocks 1 Refer to catalog page 40 to select proper operator for enclosure, pages 48 & 49 for accessories, page 40 for complete details on Area lassification of operators, page 5 for Dimensional information. Nameplates are double sided. 3 ontact Blocks are shown in their normal position. NOTE: British standards BSEN50014 and EN50018 have special marking and relamping demands that require modifications to the standard Killark Pilot Lights. Pilots lights and illuminated push buttons on this page must be used for enclosures that are modified to meet ATEX/ENELE.

45 44 G SERIES ONTROLS SELETOR SWITHES lass I, Div. 1 &, Groups B,,D4 lass I, Zones 1 &, Groups llb, lla lass II, Div. 1 &, Groups E,F,G lass Ill NEMA 3, 4, 4X, 7(B,,D) 9(E,F,G) See Area lassification hart page 40 for Details Selector Switch Maintained ontact FEATURES-SPEIFIATIONS Selector Switch Spring Return Listed - File E1379 ertified - File LR11714 See files for details or call Killark. G SELETOR SWITH MAINTAINED ONTAT 1 SHORT4 LONG EXTENDED G05-A3F G05-A3F N34 G0L5A3 G05-33G G05-33G N34 G0L533 G05-4H8H G05-4H8H N34 G0L54H8 ONTAT ARRANGEMENT3 Left Right Left enter Right TYPE OF OPERATION Two position Three position Four position G SELETOR SWITH MAINTAINED ONTAT WITHOUT ONTATS G05-A0F G05-30G G05-4H0H G05-A0F N34 G05-30G N34 G05-4H0H N34 G0L5A G0L53 G0L54H None None None Two position Three position Four position G SELETOR SWITH SPRING RETURN G06-3F G07-6G G034-6G G035-6G G06-3F N34 G07-6G N34 G014-6G N34 G015-6G N34 G0L63 G0L76 G0L146 G0L156 Left Left Left enter Left Right Right enter Right enter Right Two position spring return to left Three position spring return to center from right or left Three position spring return to center from right, maintain in left Three position spring return to center from left, maintain in right G SELETOR SWITH SPRING RETURN WITHOUT ONTATS G06-0F G07-0G G034-0G G035-0G G06-0F N34 G07-0G N34 G014-0G N34 G015-0G N34 G0L6 G0L7 G0L14 G0L15 None None None None Two position spring return to left Three position spring return to center from right or left Three position spring return to center from right, maintain in left Three position spring return to center from left, maintain in right 1Refer to catalog page 40 to select proper operator for enclosure, 48 & 49 for Accessories, 40 for complete details on Area lassification of operators, 5 for Dimensional Information, 50 for Special ontact onfigurations. Nameplates are Double sided. position marked ON-OFF and on other side. 3 position marked HAND-OFF-AUTO and on other side. 4 position is. 3ontact Blocks are shown in their normal position. 4Short style operators are suitable for lass I Group & D, lass II Group E,F,G only.

46 G SERIES ONTROLS KEYED SELETOR SWITHES 45 lass I, Div. 1 &, Groups B,,D6 lass 1, Zones 1 &, Groups llb, lla lass II, Div. 1 &, Groups E,F,G lass Ill NEMA 3, 4, 4X, 7(B,,D) 9(E,F,G) See Area lassification hart page 40 for Details Listed - File E1379 Key Operated Selector Switch ertified - File LR11714 See files for details or call Killark. FEATURES-SPEIFIATIONS G KEY SELETOR SWITH MAINTAINED ONTAT4 1 SHORT6 LONG EXTENDED ONTAT ARRANGEMENT3 TYPE OF OPERATION5 G08-A3FD G08-33G3D G08-A3FD N34 G08-33G3D N34 G0L8A3D G0L8333D Left Left enter Right Right Two position Three position G KEY SELETOR SWITH MAINTAINED ONTAT WITHOUT ONTATS4 G08-A0FD G08-30G3D G08-A0FD N34 G08-30G3D N34 G0L8A0D G0L8303D None None Two position Three position G KEY SELETOR SWITH SPRING RETURN4 G056-L3FD G036-L3FD N34 G057-36G3D G037-36G3D N34 G058-3L6G3D G038-3L6G3D N34 G059-3R6G3D G039-3R6G3D N34 G0L36L3D G0L3763D G0L38L63D G0L39R63D Left Right Left enter Right Left enter Right Left enter Right Two position spring return to left Three position spring return to center from right or left Three position spring return to center from right, maintain in left Three position spring return to center from left, maintain in right G KEY SELETOR SWITH SPRING RETURN WITHOUT ONTATS4 G056-L0FD G057-30G3D G058-3L0G3D GO59-3R0G3D G036-L0FD N34 G037-30G3D N34 G038-3LOG3D N34 G039-3R0G3D N34 G0L36L0D G0L3703D G0L38L03D G0L39R03D None None None None Two position spring return to left Three position spring return to center from right or left Three position spring return to center from right, maintain in left Three position spring return to center from left, maintain in right 1Refer to catalog page 40 to select proper operator for enclosure, pages 48 & 49 for Accessories, page 40 for complete details on Area lassification of operators, page 5 for Dimensional Information, page 50 for Special ontact onfigurations. Nameplates are Double sided. position marked ON-OFF and on other side. 3 position marked HAND-OFF-AUTO and on other side. 4 position is. 3ontact Blocks are shown in their normal position. 4All Key Operators are furnished Keyed Different If Keyed Alike is required substitute letter A for letter D in catalog number. 5Keys are removable in Left position on position selectors and in enter position on 3 position selectors. For key removal in ALL positions change in position to 0 and 3 in 3 position to 30. 6Short style operators are suitable for lass I Group & D, lass II Group E,F,G only.

47 46 G SERIES ONTROLS SPEIALTY OPERATORS Snap Switch Potentiometer and Rheostat Reset lass I, Div. 1 &, Groups B,,D4 lass I, Zones 1 &, Groups llb, lla lass II, Div. 1 &, Groups E,F,G lass Ill NEMA 3, 4, 4X, 7(B,,D) 9(E,F,G) See Area lassification hart page 40 for Details Rotary or Motor Shaft apillary Seal ertified - File LR11714 See file for details or call Killark. FEATURES-SPEIFIATIONS G SNAP SWITH OPERATOR 1 SHORT4 LONG GO30-31F GO30-33F (UL File E10501) GO10-31F N34 GO10-33F N34 TYPE SWITH SPST SPDT (3-way) RATINGS 15 VA 50 VA 10 Amp 5 Amp 10 Amp 10 Amp NAMEPLATE MARKING Off/On or Off/On or G ROTARY OR MOTOR SHAFT OPERATOR ATALOG NUMBER1 GO-165 GO-185 GO-175 GO-195 GO-50 GO-51 SHAFT DIAMETER 1/4 3/8 1/4 3/8 1/ 1/ TYPE Male-Female Male-Male DESRIPTION1 Rotary or motor shaft operator used to transfer rotary motion through wall of explosion proof enclosure. G POTENTIOMETERS AND RHEOSTATS OPERATOR 1 SHORT4 LONG EXTENDED GO133 GO134 GO113 N34 GO114 N34 (UL File E15087) GOL113 GOL114 TYPE Single turn Fifteen turn DESRIPTION1 ontrol operator for use with potentiometers or rheostats having a 1/4" diameter by 7/8" long shaft. GO50 requires 1-1/4" NPSM opening (UL File E15087) G APILLARY SEALS ATALOG NUMBER1 GO GO APILLARY SIZE 0.078±.00 Dia ±.00 Dia. TYPE Accepts apillary With Max. Bulb Dia. of 9/16". DESRIPTION1 Use where a mechanical means for passing a thermostat or similar capillary tube through the wall of a hazardous location enclosure. G RESET OPERATOR 1 SHORT3 GO40-KX LONG GO-RST EXTENDED GOLRST (UL File E15087) NAMEPLATE Reset or TYPE OPERATION1 Black plunger type reset operator, supplied with a 6 long fiber extension which can be removed or cut to desired length. 1 Refer to catalog page 40 to select proper operator for enclosure, pages 48 & 49 for Accessories, page 40 for complete details on Area lassification of operators, page 5 for Dimensional Information. Nameplates are double sided. 3 GO40 series reset button is suitable for lass II E, F, and G locations only. 4Short style operators are suitable for lass I Group & D, lass II Group E,F,G only. 5 These devices are not UL or SA approved.

48 GS/SWB SERIES ONTROLS OPERATOR BODIES 47 lass I, Div. 1 &, Groups,D lass I, Zones 1 &, Groups llb, lla lass II, Div. 1 &, Groups E,F,G lass Ill NEMA 7(,D) 9(E,F,G) SWB Series: Listed - File E10514 Style 1 - GS-16 Style - GS-163 Style 3 - SWB-16 ertified - File LR11716 See files for details or call Killark. FEATURES-SPEIFIATIONS GS STYLE 1 WITH DRILLED AND TAPPED OPERATOR HOLES IN OVER1 NO. OF ATALOG OPERATOR ONSISTS OF DIMENSIONS NUMBER HOLES BOX OVER A B D E G H I GS-13 1 SWB-13 X-60 GS-14 1 SWB-14 X-60 GS-15 SWB-15 X-61 GS-16 3 SWB-16 X-6 GS-83 4 SWB-83 X-84 GS-85 5 SWB-83 X-85 GS SWB-13 X /8" -3/8" 5/16" 5-3/16" 3-5/8" 3-1/" -9/16" (156) (60) (8) (148) (9) (89) (65) 6-1/8" -3/8" 5/16" 5-1/4" 3-5/8" 4-5/16" 3-3/8" (156) (60) (8) (133) (9) (110) (86) 7-3/8" 3-1/8" 5/16" 6-1/" 4" 1" 4-1/4" 3-1/4" (187) (79) (8) (165) (10) (5) (108) (8) 9-3/8" 3-3/16" 5/16" 8-1/" 4" " 4-1/4" 3-1/4" (38) (81) (8) (16) (108) (51) (105) (8) 13" 3-1/4" 3/8" 11-7/8" 4-3/8" 1-1/4" 4-3/16" 3-1/4" (330) (8) (10) (30) (111) (3) (106) (8) 13" 3-1/4" 3/8" 11-7/8" 4-3/8" " 4-3/16" 3-3/16" (330) (8) (10) (30) (111) (51) (106) (81) GS STYLE WITH DRILLED AND TAPPED OPERATOR HOLES IN BAK OF BOX1 GS SWB-14 X-10 GS-15 SWB-15 X-11 GS SWB-16 X-1 GS SWB-83 X-83 GS SWB-83 X /8" -3/8" 5/16" 5-3/16" 3-5/8" 3-1/" -9/16" (156) (60) (8) (148) (9) (89) (65) 6-1/8" -3/8" 5/16" 5-1/4" 3-5/8" 4-5/16" 3-3/8" (156) (60) (8) (133) (9) (110) (86) 7-3/8" 3-1/8" 5/16" 6-1/" 4" 1" 4-1/4" 3-1/4" (187) (79) (8) (165) (10) (5) (108) (8) 9-3/8" 3-3/16" 5/16" 8-1/" 4" " 4-1/4" 3-1/4" (38) (81) (8) (16) (10) (51) (108) (8) 13" 3-1/4" 3/8" 11-7/8" 4-3/8" 1-1/4" 4-3/16" 3-1/4" (330) (8) (10) (30) (111) (3) (106) (8) 13" 3-1/4" 3/8" 11-7/8" 4-3/8" " 4-3/16" 3-3/16" (330) (8) (10) (30) (111) (51) (106) (81) Dimensions Notes: Use short style operators for cover devices and long style operators for back of box mounted devices when panel mounting. Style control stations with holes in back of box are typically used for panel mounting. SWB STYLE 3 BLANK BOX AND OVER - NO OPERATOR HOLES1 SWB-13 None SWB-13 X-10 SWB-14 None SWB-14 X-10 SWB-15 None SWB-15 X-11 SWB-16 None SWB-16 X-1 SWB-83 None SWB-83 X /8" -3/8" 5/16" 5-3/16" 3-5/8" 3-1/" -9/16" (156) (60) (8) (148) (9) (89) (65) 6-1/8" -3/8" 5/16" 5-1/4" 3-5/8" 4-5/16" 3-3/8" (156) (60) (8) (133) (9) (110) (86) 7-3/8" 3-1/8" 5/16" 6-1/" 4" 4-1/4" 3-1/4" (187) (79) (8) (165) (10) (108) (8) 9-3/8" 3-3/16" 5/16" 8-1/" 4" 4-1/4" 3-1/4" (38) (81) (8) (16) (111) (108) (8) 13" 3-1/4" 3/8" 11-7/8" 4-3/8" 4-3/16" 3-3/16" (330) (8) (10) (30) (111) (106) (81) 1All GS and SWB Series are cataloged without conduit openings. Specify conduit size and location when ordering. GS-83, GS-834, and GS-85, GS-835 are provided with four mounting lugs.

49 48 G SERIES ONTROLS AESSORIES/REPLAEMENT PARTS Rubber Boot Hole Plug Trim Locknut Spacer Transformer GO-8670 Push Button Lockout GO-8665 AESSORIES Push Button Lockout GO-1050 USED ON OPERATOR TYPE DESRIPTION GO GO GO GO-8177 GO-8 GO GO GO GO GO-8665 GO-1050 GO567-LOK GO-RL GO-984 B7PLR0 B7PLR440 B7PLR550 GOLED-R110 GOLED-G110 GOLED-A110 GO1, GO1, GOL1 GO1, GO1, GOL1 GO1, GO1, GOL1 3/4 NPSM 1/4 Thick, Used as external spacer. GO3, GOB3, GOL3 GO3, GOB3, GOL3 GOB4, GOL4 GOB4, GOL4 GO, GO, GOL, GOR11 GO1, GO1, GOL1 GO & GOL For use with GO s GO40, GO-RST, GOLRST GO3, GOB3, GOL3, GOB4, GOL4 GO3, GOB3, GOL3, GOB4. GOL4 GO3, GOB3, GOL3, GOB4, GOL4 GOB3, GOL3, GOB4, GOL4 GOB3, GOL3, GOB4, GOL4 GOB3, GOL3, GOB4, GOL4 Protective rubber boot (Black) Protective rubber boot (Red) Protective rubber boot (Green) Hole plug Trim locknut spacer Transformer 0V-110V Transformer 440V-110V Transformer 0V-110V Transformer 440V-110V Push button lockout Push button lockout Selector switch lockout Sealing lockout Reset plate Resistor kit 0V-110V Resistor kit 440V-110V Resistor kit 550V-110V LED lamps 10V (Red) LED lamps 10V (Green) LED lamps 10V (Amber) Selector Switch Lockout Reset Plate Sealing Locknut GO-RL Lens Guard Assembly REPLAEMENT LENS GUARD ASSEMBLIES GOL3/GOB3/GO3 SERIES GOL4/GOB4 SERIES LENS OLOR GO1576-A KIT-354 Amber GO1576-B KIT-355 Blue GO1576- KIT-356 lear GO1576-F KIT-357 Frosted GO1576-G KIT-358 Green GO1576-R KIT-359 Red REPLAEMENT BLANK NAMEPLATES DESRIPTION YOKK Push button pilot lights YOKK-1091 Double push button YOKK-1086 Position selector switch YOKK Position selector switch YOKK Position selector switch

50 G SERIES ONTROLS AESSORIES/REPLAEMENT PARTS GOMLOK Standard Mushroom Momentary Jumbo Mushroom Momentary AESSORIES FOR USE ON OPERATOR TYPE DESRIPTION GOMLOK GOM1-GOM1-GOML-GO1-GO1-GOL1 GOMSTG GO1-GO1-GOL1 GOMSTR GO1-GO1-GOL1 GOMSTK GO1-GO1-GOL1 GOMJUR GO1-GO1-GOL1 Dimensions - Standard Mushroom - 1-1/ Diameter Jumbo Mushroom - -1/4 Diameter Lock Out for Standard Size Momentary & Maintained Head Standard Size Momentary Mushroom Head (Green) Standard Size Momentary Mushroom Head (Red) Standard Size Momentary Mushroom Head (Black) Jumbo Size Momentary Mushroom Head (Red) Replacement Parts Slide Base GO3 Bayonet Base GOL3/GOL4 GOB3/GOB4 ontact Block PILOT LIGHT LAMPS ATALOG NUMBER VOLTS WATTS AMPS STYLE GO GO GO3 YOSY10MB GOB3/GOL3 YOSY4MB GOB4/GOL4 GO STANDARD ONTAT BLOKS DESRIPTION GO-867-BJK 1 N.O. GO-867-BJJ 1 N.. GO-867-BJH 1 N.O. Early make GO-867-BJE 1 N.. Late break LED Lamp for G083/G0L3 - G0B4/G0L4 PILOT LIGHT LED LAMPS VOLTS OLOR GOLED-A VA/D Amber GOLED-B VA/D Blue GOLED-G VA/D Green GOLED-R VA/D Red GOLED-W VA/D White GOLED-A4 4 VA/D Amber GOLED-B4 4 VA/D Blue GOLED-G4 4 VA/D Green GOLED-R4 4 VA/D Red GOLED-W4 4 VA/D White

51 50 G SERIES ONTROLS USTOM OPERATOR ORDERING SYSTEM Example: GO1 FORM SINGLE PUSH BUTTON LONG STYLE RX OLOR (RED) ONTATS (1 N..) B NAMEPLATE (STOP) N34 ONSTANT NOTE: For faster delivery on custom operators order push buttons and selector switches without contact blocks and order contacts as a separate item. FEATURES-SPEIFIATIONS 1.Select operator form and style (short, long or extended)..using the catalog numbering system below, insert the proper letter or number symbol as shown in appropriate charts on page 51, write the complete catalog number. 3.Spaces in catalog numbering system which have symbol already filled in cannot be changed. 4.Order accessories as separate item from pages 48 & Add N34 suffix to the end of all long style operators with the following prefix; G01, G0, G0B3, G0B4, G05, G06, G07, G08, G010, G011, G014, G015, G036, G037, G038, G039. ATALOG SERIES OLOR VOLTAGE POSITION AM ONTATS NAMEPLATE KEY LOK KEY TYPE GO1 & GO1 GOL1 GOM1 GO & GO GOL GO11 GOB3 & GO3 GOL3 GOB4 GOL4 GO5 & GO5 GOL5 GO6 & GO6 GOL6 GO7 & GO7 GOL7 GO14 & GO34 GOL14 GO15 & GO35 GOL15 GO8 & GO8 GOL8 GO36 & GO56 GOL36 GO37 & GO57 GOL37 GO38 & GO58 GOL38 GO39 & GO59 GOL39 hart 1 hart 1 hart hart hart 3 hart 3 hart 6 hart 6 hart 5 hart 5 hart 7 hart 7 hart 4 hart 4 hart 4 hart 4 hart 4 hart 4 hart 4 hart 4 hart 4 hart 4 hart 4 hart 4 hart 4 hart 4 hart 4 hart 8 hart 8 hart 8 hart 8 hart 8 hart 8 hart 8 hart 8 hart 8 hart 8 hart 8 hart 8 hart 8 hart 8 hart 8 hart 8 hart 9 hart 9 hart 9 hart 9 hart 9 hart 10 hart 10 hart 10 hart 10 hart 10 Single push button: (Momentary contact) Single push button: (Maintained contact) Double push button: (Momentary contact) Double push button: (Maintained contact) Pilot light DESRIPTION Illuminated push button Selector switch (Maintained contact) Selector switch ( Position, spring return to left) Selector switch (3 Position, return to center from center) Selector switch (3 Position, return to center from right) Selector switch (3 Position, return to center from left) Key selector switch (Maintained contact) Key selector switch ( Position, spring return to left) Key selector switch (3 Position, spring return to center) Key selector switch (3 Position, return to center from right) Key selector switch (3 Position, return to center from left)

52 HAZARDOUS AND HOSTILE LOATIONS G SYMBOLS FOR ORDERING USTOM OPERATORS 51 HART 1 SINGLE BUTTON GO1 GO1 GOL1 GOM1 SYMBOL SYMBOL SYMBOL SYMBOL OLOR KX KZ K KM Black RX RZ R RM Red GX GZ G GM Green HART 7A SELETOR SWITH AMS AM AND ONTAT SELETION TABLE FOR AND 3 POSITION SELETOR OPERATOR Left enter Right position position position HART DOUBLE BUTTON SYMBOL OLOR KK Black/Black GG Green/Green RR Red/Red RG Red/Green KR Black/Red KG Black/Green HART 3 PILOT LIGHT LENS SYMBOL OLOR A Amber B Blue lear F Frosted G Green R Red SYMBOL A B D E G ONTATS BLOKS N NO N NO N NO N NO N NO N NO LEFT RIGHT LEFT RIGHT LEFT RIGHT BLOKS BLOKS BLOKS BLOKS BLOKS BLOKS X X O O O O X X X O X X O X O X O O X O X X O O O O O O O O X X O O X X O O O O O O X X O O X X O O X X O O O O X O O X O O O O O O X X Note: Spring return operators are supplied with special fixed cam. hanges cannot be made for cam substitution. HART 4 ONTAT BLOKS SYMBOL ARRANGEMENT 1 One N.O. block One N.. block One universal 3 (One N.O. and one N..) One delayed break 4 N.. block One early make N.O. 5 block 6 Two N.O. blocks 7 Two N.. blocks Two universal 8 (Two N.O. and two N..) 0 Omit contact block HART 5 SELETOR SWITHES SYMBOL NO. OF POSITIONS Two 3 Three HART 8 NAMEPLATES1 NAMEPLATE MARKINGS G SERIES FORMS THAT SYMBOL FRONT BAK NAMEPLATE AN BE USED ON A Omit nameplate Omit nameplate All B Start Stop GO1, 1, 3, 0, 40, GOB3 Reset GO1, 1, 3, 0, 40, GOB3, GOB4 E On GOR4 F - Off-On GO5, 5, 6, 6, 8, 8, 10, 30, 36, 56 G -- Hand-Off-Auto GO5, 5, 7, 7, 8, 8, 10, 30, 14, 34 H --- Start-Stop GO5, 5, 10, 30 HART 9 KEY LOK SYMBOL TYPE Position key remove left 0 Position key remove both 3 3 Position key remove center 30 3 Position key remove all HART 10 - KEY STYLE SYMBOL D A TYPE Keys different Keys alike 1Symbol not required on extended length GOL part number. HART 6 PILOT LIGHT LAMPS GO3 GOB3/GOB4 SYMBOL SYMBOL VOLTAGE

53 5 G SERIES ONTROLS DIMENSIONS G DIMENSIONS Push Buttons SERIES FIGURE A B D GO1 GO GOB3 GOB4 GO5 GO6,GO7,GO14,GO15 GO8 GO10 GO16,GO18 GO17,GO19 GO1 GO GO3 GO5 GO6,GO7,GO34,GO35 GO30 GO36,GO37,GO38,GO39 GO40 GO50 GO51 GO56,GO57,GO58,GO59 GO113,GO114 GO133,GO134 GO GO GOR11 GO-RST GOM1 EXTENDED LENGTH OPERATORS: GOL1 GOL GOL3 GOL4 GOL5 GOL6,GOL7,GOL14,GOL15 GOL8 GOL36,GOL37,GOL38,GOL GOL113,GOL114 GOLRST /16"(4) 13/16"(1) 1-1/8"(9) -3/8"(60) 1-5/16"(33) 1-5/16"(33) -9/16"(65) 1-5/16"(33) 1-1/4"(3) 13/16"(1) 15/16"(4) 13/16"(1) 1-1/8"(9) 1-5/16"(33) 1-5/16"(33) 1-5/16"(33) -9/16"(65) 15/16"(4) 1-1/"(38) -1/4"(57) -9/16"(65) 1"(5) 1"(5) 1-5/16"(33) 1-5/16"(33) 13/16"(1) 15/16"(4) 1-7/8"(48) 15/16"(4) 13/16"(10) 1-1/8"(9) -3/8"(60) 1-5/16"(33) 1-5/16"(33) -9/16"(65) -9/16"(65) 1"(5) 15/16"(4) 1-3/4"(44) "(51) "(51) -1/4"(57) 1-3/4"(44) 1-3/4"(44) 1-3/4"(44) 1-3/4"(44) 1"(5) 1"(5) 3/4"(19) 1"(5) 1"(5) 3/4"(19) 3/4"(19) 3/4"(19) 1-3/4"(00) 11/16"(17) "(51) 1-5/8"(41) 3/4"(19) "(51) 1"(5) 3/4"(19) 3/4"(19) "(51) -5/16"(59) 1-7/16"(37) -3/4"(70) -3/4"(70) -3/4"(70) -3/4"(70) -3/4"(70) -3/4"(70) -3/4"(70) -3/4"(70) 3"(76) -3/4"(70) 3-7/16"(87) 3-3/4"(95) -3/4"(70) 4"(101) 3-7/16"(87) 3-13/16"(97) 3-1/"(89) 4"(101) 13/16"(1) 13/16"(1) -7/16"(6) -3/4"(70) 1-3/4"(44) -7/16"(6) -13/16"(71) 3"(76) 3-7/8"(98) 1"(5) 6-5/16"(160) 5-9/16"(141) -7/8"(73) 3-5/8"(67) -5/8"(67) N/A N/A 4-1/8"(105) -3/8"(+6")(60) 4"(101) 4-7/16"(113) 4-1/"(114) 3-3/8"(86) 4-5/8"(117) 4-7/16"(113) 4-13/16"(1) 4-1/"(114) 4-7/8"(14) 4-5/8"(117) 3"(+6")(76) 1-1/4"(3) 1-9/16"(40) 1-13/16"(46) 1-1/4"(3) 1-1/4"(3) 1-1/4"(3) 1-1/4"(3) 1-1/"(38) 1-1/"(38) 1-1/4"(3) 1-9/16"(40) 1-1/4"(3) 1-1/4"(3) 1-1/4"(3) 1-1/4"(3) 1-1/4"(3) -5/16"(59) 1"(5) 1-1/4"(3) 1-13/16"(46) 1-13/16"(46) 1-1/"(38) 1-1/"(38) 1-1/4"(3) 1-5/8"(41) 1-1/4"(3) 1-9/16"(40) 1-13/16"(46) 1-1/4"(3) 1-1/4"(3) 1-1/4"(3) 1-1/4"(3) 1-13/16"(46) 1-1/4"(3) Pilot Lights FIGURE 1 FIGURE FIGURE 3 FIGURE 4 NOTE: All operators are for installation into a 3/4"-14 NPSM opening except GO50 which is for 1-1/4"-11-1/ NPSM and GO GO which are for use in a 3/4"-14 NPT opening. FIGURE 5 Special Operators Selector Switches FIGURE 6 FIGURE 7 FIGURE 8 FIGURE 9 FIGURE 10 FIGURE 11

54 B7 SERIES ONTROLS MAGNETI MOTOR STARTERS 53 lass I, Div. 1 &, Groups B,,D lass l, Zones 1 &, Groups llb, lla lass II, Div. 1 &, Groups E,F,G lass III, Div. 1 & NEMA 3, 4, 4X, 7(B,,D) 9(E,F,G) lassified - File E83969 ertified - File LR11714 See files for details or call Killark. Line Starter ombination Starter FEATURES-SPEIFIATIONS Applications The PRISM B7 Series of across-theline starter and combination motor control centers utilize SSNR single-speed, non-reversing NEMA type starters. Prism enclosures universal design accommodates, as standard, the magnetic starters made by the following manufacturers: Allen-Bradley 509 Series utler-hammer A10 Series utler-hammer AN16 Series Furnas lass 14 Series GE R306 Series Square D 8536 Series Telemecanique A0 Series Westinghouse A00 Series In addition, the SSNR combination starters will house a motor circuit protector or circuit breakers manufactured by: Square D FA, FH, F Frames utler-hammer HM, EHD, FDB, FD, HFD, FD Frames General Electric TEB-TE-TED- THED-Frame There is sufficient space in the combination starter enclosure for a control transformer, if required. Standard Materials Enclosure opper-free aluminum O-ring Gasket BUNA-N nitrile over Bolts 316 grade stainless steel B/MP Handle opper-free aluminum Reset Operator Thermoplastic polyester button molded onto stainless steel shaft. Aluminum shroud. Mounting Pan Sheet aluminum Hinge Aluminum with stainless steel pin Reset Shroud Black anodized Features Nema 4, 4X rated providing protection from hose directed water and corrosion Universal mounting pan, pre-drilled to facilitate easy field installation of starters. Provision for grounding supplied as standard. More wiring room meets latest NE wire bend requirements Quick release, captivated cover bolts of 316 grade stainless steel Flange sealing gasket located to the inside of cover bolt preventing water seepage into enclosure through bolt holes Hinged cover provided as standard for an extra measure of safety and convenience Breaker (MP) handle can be padlocked in ON or OFF position Provisions provided for drain and breather plus conduit openings for power and control Reset button provided as standard Two control operator openings provided plugged as standard. Additional openings can be factory or field drilled. opper-free (less than 4/10 of 1% copper) enclosure Ductile mounting lugs atalog Logic See page 58 for enclosures with controls.

55 54 B7 SERIES ONTROLS MAGNETI MOTOR STARTERS Line Starter ombination Starter lass I, Div. 1 &, Groups B,,D lass l, Zones 1 &, Groups llb, lla lass II, Div. 1 &, Groups E,F,G lass III, Div. 1 & NEMA 3, 4, 4X, 7(B,,D) 9(E,F,G) lassified - File E83969 ertified - File LR11714 See files for details or call Killark. FEATURES-SPEIFIATIONS Magnetic Line Starters - 3 Pole, 3 Phase, Single Speed Non Reversing 600 VA Max, 60Hz Square D or utler-hammer motor starters available as standard. Heaters not included. See page 59 to order. B7 MAGNETI LINE STARTERS NEMA MOTOR OIL STARTER VOLTS VOLTS1 MAX. HP UTLER-HAMMER SQUARE D SIZE SERIES AN16 SERIES SEP. ONTROL SEP. ONTROL SEP. ONTROL SEP. ONTROL SEP. ONTROL / B7010HB B7010HG B7010HK B7010HM B7011HB B7011HG B7011HK B7011HM B701HB B701HG B701HK B701HM B7013HB B7013HG B7013HK B7013HM B7014HB B7014HG B7014HK B7014HM B7010SB B7010SG B7010SK B7010SM B7011SB B7011SG B7011SK B7011SM B701SB B701SG B701SK B701SM B7013SB B7013SG B7013SK B7013SM B7014SB B7014SG B7014SK B7014SM ENLOSURE ONLY NO INTERIORS B7011 B7011 B701 B7013 B See catalog logic page 58 for other standard coil voltages. ontrol transformers for use on ombination Starters Only. Will not fit into B701 Series of Non- ombination Starters. 3 See catalog page 58 for modifications and accessories to enclosure.

56 B7 SERIES ONTROLS MAGNETI MOTOR STARTERS 55 ombination Starters 3-Pole, 3-Phase, Single Speed Non Reversing 600 VA Max, 60Hz Square D or utler- Hammer motor starters and motor circuit protector available. Heaters not included. See page 59 to order. Enclosure sized to accommodate control circuit transformer. B7 OMBINATION MAGNETI LINE STARTERS NEMA STARTER SIZE MOTOR VOLTS SEP. ONTROL SEP, ONTROL SEP, ONTROL SEP, ONTROL SEP. ONTROL SEP. ONTROL SEP, ONTROL SEP, ONTROL SEP, ONTROL SEP, ONTROL SEP, ONTROL DISONNET OIL VOLTS1 MAX. HP ENLOSURE ONLY TRIP UTLER-HAMMER SQUARE D NO INTERIORS AMPS SERIES AN16 SERIES / B700HBA B700HBB B700HB B700HGB B700HG B700HKA B700HKB B700HK B700HMA B700HMB B700HM B701HB B701HBF B701HGF B701HKF B701HMF B70HBK B70HBM B70HGK B70HGM B70HKK B70HMK B703HBQ B703HGQ B703HKQ B703HMQ B704HBT B700SBAA B700SBAB B700SBA B700SGAB B700SGA B700SKAA B700SKAB B700SKA B700SMAA B700SMAB B700SMA B701SBA B701SBAF B701SGAF B701SKAF B701SMAF B70SBAK B70SBAM B70SGAK B70SGAM B70SKAK B70SMAK B703SBAQ B703SGAQ B703SKAQ B703SMAQ B704SBBT B701 B701 B70 B B704HGT B704SGBT B704HKT B704SKBT B B704HMT B705BMPJ50 B705BMPK400 B705GMPJ50 B705GMPK400 B705KMPJ50 B705KMPK400 B705MMPJ50 B705MMPK400 B704SMBT B705SBSMAGK50 B705SBSMAGL400 B705SGSMAGK50 B705SGSMAGL400 B705SKSMAGK50 B705SKSMAGL400 B705SMSMAGK50 B705SMSMAGL400 See chart below 1 See catalog logic page 58 for other standard coil voltages. ombination Starter enclosures provide sufficient space for factory of field mounting a control transformer. 3 See catalog page 58 for modifications and accessories to enclosure. SIZE 5 OMBINATION MOTOR STARTER ENLOSURE ONLY STARTER MANUFATURER Allen Bradley Allen Bradley utler Hammer utler Hammer General Electric General Electric Square D Square D Westinghouse Westinghouse STARTER TYPE Series 509 Series 509 Freedom-AN16 Freedom-AN16 Series 306 Series 306 Series 8536 Series 8536 Advantage Advantage -H J K J K J K J K J K IRUIT BREAKER FRAME GE SQ-D F-5 K J-600 L F-5 K J-600 L F-5 K J-600 L F-5 K J-600 L F-5 K J-600 L ENLOSURE AT. NUMBER B705A B705A4 B705 B7054 B705G B705G4 B705S B705S4 B705W B705W4

57 56 B7 SERIES ONTROLS OMBINATION STARTERS Supplied with utler-hammer Advantage Starters Applications The PRISM B7 Series of ombination Starters are used for Motor ontrol and ircuit protection of motors in Hazardous And Hostile locations. These Hazardous locations are typically due to the presence of flammable gases or vapors, combustible dust, or easily ignitable fibers and flyings, and areas which are subject to corrosion, weather and dampness. Advantage Starter Features Solid-State Electronic Starter Brownout Protection ommunications capabilities Overload Heaters not required Phase loss and phase unbalance protection Selectable automatic/manual reset lass ll ground-fault protection Enclosure Features Nema 4, 4X rated providing protection from hose directed water and corrosion Universal mounting pan, pre-drilled to facilitate easy field installation of starters. Provision for grounding supplied as standard. More wiring room meets latest NE wire bend requirements Quick release, captivated cover bolts of 316 grade stainless steel Flange sealing gasket located to the inside of cover bolt preventing water seepage into enclosure through bolt holes Hinged cover provided as standard for an extra measure of safety and convenience Breaker (MP) handle can be padlocked in ON or OFF position Provisions provided for drain and breather plus conduit openings for power and control Field replaceable reset button provided as standard with gold contact blocks Two control operator openings provided plugged as standard. Additional openings can be factory or field drilled opper-free (less than 4/10 of 1% copper) enclosure Ductile mounting lugs Modifications & Accessories Select from B7 Modification hart on page 58 Minimum ontrol Transformer Size 1-100VA Size VA Size 5 300VA Advantage Starters Auxiliary ontact Modules NO/N = B7ADA lass I, Div. 1 &, Groups B,,D lass l, Zones 1 &, Groups llb, lla lass II, Div. 1 &, Groups E,F,G lass III, Div. 1 & NEMA 3, 4, 4X, 7(B,,D) 9(E,F,G) lassified - File E83969 ertified - File LR11714 See files for details or call Killark. Standard Materials Enclosure opper-free aluminum O-ring Gasket BUNA-N nitrile over Bolts 316 grade stainless steel B/MP Handle opper-free aluminum Reset Operator Thermoplastic polyester button molded onto stainless steel shaft. Aluminum shroud. Mounting Pan Sheet aluminum Hinge Aluminum with stainless steel pin Reset Shroud Black anodized B7AD OMBINATION STARTER NEMA STARTER SIZE 1L MOTOR VOLTS MAXIMUM HP 1 7-1/ OIL VOLTS 10/60 10/60 10/60 10/60 10/60 10/60 FULL LOAD AMPERAGE RANGE(1) DISONNET AMP TRIP WITH MOTOR PROTETOR AND STARTER ENLOSURE ONLY B7AD0LH6A B7AD0LH6B B7AD01 B7AD0LH6 B7AD01H6F B7ADO1 B7AD0H6K B7AD0 B7AD03H6Q B7AD03 B7AD04H6T B7AD04 B7AD05H6K400 B7AD05K Notes: (1) Heaters are not required with the Advantage Starter. The Overload Module has trip current settings via DIP Switch between the amperage range shown. () All Advantage Starters are wired for separate control and must be controlled at the coil voltage shown. For 50 HZ applications a 110V 50 Hz coil is available. To order with this 50 Hz coil replace the number 6 in catalog number with 5. (3) Enclosures provide sufficient space for factory or field mounting a control transformer.

58 B7 SERIES ONTROLS MOTOR STARTERS DIMENSIONS 57 B7 DIMENSIONS EST. ONDUIT OPENINGS ATALOG NEMA DIMENSIONS ENLOSURE TOP/BOTTOM (IN.)1 TYPE NUMBER SIZE WEIGH DRAIN & A B D E F G H I POWER ONTROL (LBS.) BREATHER Starter Only 18" 11" 9-1/8" 3-5/8" 16-3/8" -1/8" -3/8" -11/16" 3-7/16" B7011 0,1 (457) (80) (3) (9) (416) (54) (60) (68) (87) /" 3/4" 1/" B701 B B B701 0,1 B70 B703 3 B704 4 Starter Only Starter Only Starter Only ombination Starter ombination Starter ombination Starter ombination Starter 0" 1-1/" 9-1/8" 5" 18-3/8" -1/" -1/" -11/16" 3-3/16" (508) (317) (3) (17) (467) (63) (63) (68) (81) 6-1/4" 1-1/" 10-3/4" 5" 4-5/8" -1/" -3/4" 4-1/16" 5-1/" (667) (317) (76) (17) (65) (63) (70) (103) (140) 34-1/4" 16-1/" 11-1/" 9" 3-5/8" 3-3/4" 4" 4-7/16" 6" (870) (419) (9) (9) (830) (95) (10) (113) (15) 3" 14-1/" 9-1/8" 7" 1-3/8" -1/8" -1/" -11/16" 3-7/16" (584) (368) (3) (178) (543) (54) (64) (68) (87) 5-1/" 14-1/" 9-1/8" 7" 3-7 8" -1/8" -1/" -11/16" 3-7/16" (648) (368) (3) (178) (606) (54) (64) (68) (87) 7-1/4" 17-7/8" 11" 10-3/8" 5-5/8" 3-1/" 3-1/" 4-3/16" 5-1/" (69) (454) (80) (63) (651) (89) (89) (106) (140) 34-1/4" 1-1/" 11-7/8" 14" 3-5/8" 4-3/4" 5" 4-9/16" 6-3/16" (870) (546) (30) (356) (89) (11) (17) (116) (157) /" 3/4" 1/" 80 " 1" 1/" 155 3" 1" 1/" /" 3/4" 1/" /" 3/4" 1/" 143 " 1" 1/" 35 3" 1" 1/" 1 1/" conduit openings may be used for drain and/or breather installation. Smaller conduit openings may be used by utilizing reducing bushings. ustom conduit sizes and locations are available upon request. DIMENSIONS FOR SIZE 5 OMBINATION STARTER DIMENSIONS ONDUIT TOP & BTM. (NTP) ENL. WT. A B D E F G H I J K L M (LBS.) 6-1/4" 0-1/4" 15" 18-1/" 43-1/" -5/8" 3-1/8" 5-3/8" 7-3/8" 3-1/ 4" 1/" 1" (1581) (514) (381) (470) (1105) (67) (79) (137) (187) (89) (10) (13) (5) 540 Dimensions B7 Size 0 Thru 4 Dimensions B7 Size 5

59 58 B7 SERIES ONTROLS MOTOR STARTERS AESSORIES/ATALOG LOGI B7 MODIFIATIONS AND AESSORIES B7 MODIFIATIONS AND AESSORIES (ONTINUED) DESRIPTION SIZE 0 THRU 4 SIZE 5 SIZE 0 THRU 4 SIZE 5 DESRIPTION B7DBP B7EDBP Double pushbutton (Start/Stop) B7T100 ontrol transformer 100VA (0,1,)* B7RPL B7ERPL Red pilot light 10 Volt B7T150 ontrol transformer 150VA (0,1,)* B7GPL B7EGPL Green pilot light 10 Volt B7T00 ontrol transformer 00VA (3,4)* B7APL B7EAPL Amber pilot light 10 Volt B7T50 ontrol transformer 50VA (3,4)* B7LPBR B7ELPBR Illuminated red pushbutton 10 Volt B7T300 ontrol transformer 300VA (5)* B7LPBG B7ELPBG Illuminated green pushbutton 10 Volt B7T500 ontrol transformer 500VA (5)* B7LPBA B7ELPBA Illuminated amber pushbutton 10 Volt KB1B KB1B Breather** (not SA) B7PLR0 B7PLR0 Pilot light resistor 0 Volt to 110 Volt KB1D KB1D Drain** (not SA) B7PLR440 B7PLR440 Pilot light resistor 440 Volt to 110 Volt KIT-51 KIT-51 Grounding kit B7PLR550 B7PLR550 Pilot light resistor 550 Volt to 110 Volt B7SF B7SF Special finish - Baked epoxy outside B7SS B7ESS position selector switch ( On-Off ) B7DLO B7DLO Delete lock ON feature for breaker handle B7SSHOA B7ESSHOA 3 position selector switch ( Hand-Off-Auto ) B7SH51 B7SH51 Space heater 5 Watt 10 Volt B7HA B75A utler Hammer auxiliary contact (1NO/1N) B7SH5 B7SH5 Space heater 5 Watt 40 Volt B7SA B75SA Square D auxiliary contact (1NO/1N) B7SH54 B7SH54 Space heater 5 Watt 480 Volt B7TB B7TB Terminal block ( 6 Terminals ) B7SH501 B7SH501 Space heater 50 Watt 10 Volt B7IPR Interposing relay 10 Volt coil B7SH50 B7SH50 Space heater 50 Watt 40 Volt B7T50 ontrol transformer 50VA (0,1,)* B7SH504 B7SH504 Space heater 50 Watt 480 Volt B7T75 ontrol transformer 75VA (0,1,)* * ontrol transformers are primary 40/480 - Secondary 10 Volt. ontrol transformers for use on ombination Starters Only. Will not fit into B701 Series of Non-ombination Starters. * All control transformers include fused primary and secondary circuits. ** Installation of drains and breathers will void the NEMA4-4x ratings - voids Group B for SA. atalog Logic B7 Enclosures with ontrols B7 Series onstant Starter Type 01Non-ombination (SSNR) 0ombination (SSNR) Starter Size Starter Manufacturer SSquare D Hutler-Hammer (Freedom) Starter oil Voltage A110V-60HZ B10/110V-60/50HZ 10/40V=60/50HZ D08/0V-60HZ E08/0/480V-60HZ F0V-60HZ G40/0V-50/60HZ H40/480V-60HZ J440/380V-60/50HZ K480/440V-60/50HZ L550V-60HZ M600/550V-60/50HZ N600V-50HZ VSpecify Voltage Disconnect Means ASq. D. FAL Mag Guard BSq. D. KAL Mag Guard utler-hammer HMP Motor.R. Protector DSq. D. FAL Thermal Magnetic ESq. D. FHL Thermal Magnetic FSq. D. FL Thermal Magnetic GSq. D. KAL Thermal Magnetic HSq. D KHL Thermal Magnetic JSq. D. KL Thermal Magnetic Kutler-Hammer EHD Thermal Magnetic Lutler-Hammer FDB Thermal Magnetic Mutler-Hammer FD Thermal Magnetic Nutler-Hammer HFD Thermal Magnetic Putler-Hammer FD Thermal Magnetic Disconnect urrent Rating A3 AMP B7 AMP 15 AMP D0 AMP E5 AMP F30 AMP G35 AMP H40 AMP J45 AMP K50 AMP L60 AMP M70 AMP N80 AMP P90 AMP Q100 AMP R110 AMP S15 AMP T150 AMP U175 AMP V00 AMP W5 AMP X50 AMP This atalog Logic hart is for reference only and is to be used for selection of special voltage and amperage requirements. onsult Factory since not all assemblies are available with complete list of options displayed.

60 OVERLOAD HEATERS/NON-REVERSING ONTROLS 3-POLE, 60HZ, 600VA SINGLE-SPEED 59 Overload heaters are not supplied as part of the starter assemblies and are to be ordered as separate items by catalog number and priced accordingly. Heaters should be selected on the basis of the actual full-load current and service factor as shown on the motor nameplate or in the manufacturer s published literature. When motor and overload relay are in the same ambient and the service factor of the motor is 1.15 to 1.5, select heaters from the heater selection chart. If the service factor of the motor is 1.0, or there is no service factor shown, or a maximum of 115% protection is desired, select one size smaller heater than indicated. When motor and overload relay are in different ambients, select heaters from the chart using adjusted motor currents as follows: decrease rated motor current 1% for each motor ambient exceeds controller ambient; increase rated motor current 1% for each controller ambient exceeds motor ambient. SQUARE D 8536 SERIES STARTERS SSNR NEMA SIZES 0-1 THROUGH 5 ATALOG NUMBER KB044 KB051 KB057 KB063 KB071 KB081 KB09 KB103 KB116 KBI30 KBI45 KB167 KB188 KB10 KB40 KB65 KB330 KB300 KB370 KB415 KB485 KB550 KB65 KB690 KB770 KB80 KB910 KB10 KB115 KB18 KB014 KB155 KB175 KB195 KB0 FULL-LOAD URRENT (AMPS) ATALOG NUMBER FULL-LOAD URRENT (AMPS) ATALOG NUMBER FULL-LOAD URRENT (AMPS) ATALOG NUMBER FOR SIZE 0-1 FOR SIZE 1 FOR SIZE 3 FOR SIZE 4 KB KB KB KB KB KB KB KB KB485 KB550 KB65 KB690 KB770 KB80 KB910 KB10 KB115 KB18 KB014 KB155 KB175 KB195 KB0 KB05 KB80 KB03 KB036 KB040 KB045 KB050 KB056 KB06 KB070 KB079 KB088 FOR SIZE K09 K8 K46 K63 K88 K310 K333 K364 K396 K47 K466 K501 K545 K594 K643 K685 K749 K815 K877 K940 K103 K11 K11 K13 K143 K156 K167 K180 K K643 K685 K746 K815 K877 K940 K103 K11 K11 K13 K143 K156 K167 K180 K196 K08 K19 KDD11 KDD11 KDD18 KDD140 KDD150 KDD160 KDD185 KDD0 KDD40 KDD50 KDD65 KDD80 KDD300 KDD30 KDD30 FULL-LOAD URRENT (AMPS) FOR SIZE NOTE: Square D 8536 series starters SSNR ambient compensated 0 to 60 block type overload using 3 heaters. Three required for each starter. UTLER-HAMMER HEATER (EAH HEATER PAK ONSISTS OF 3 HEATERS) ATALOG NUMBER KH001B-3 KH00B-3 KH003B-3 KH004B-3 KH005B-3 KH006B-3 KH007B-3 KH008B-3 KH009B-3 KH010B-3 KH011B-3 KH01B-3 KH013B-3 KH014B-3 MOTOR FULL-LOAD AMPERE RATING DIAL POSITION A B D FOR SIZES ATALOG NUMBER KH015B-3 KH016B-3 KH017B-3 KH018-3 KH019-3 KH00-3 KH01-3 KH0-3 KH03-3 KH04-3 KH004B-3 KH005B-3 KH006B-3 KH007B-3 KH008B-3 MOTOR FULL-LOAD AMPERE RATING DIAL POSITION FOR SIZE FOR SIZES A B D FOR SIZE

61 60 Y7 SERIES ONTROLS MOTOR STARTERS-MAGNETI LINE STARTERS lass I, Div. I &, Groups,D lass 1, Zones 1 &, Groups llb, lla lass II, Div. 1 &, Groups E,F,G lass Ill NEMA 7(,D) 9(E,F,G) ertified - File LR11714 Y7011ZH FM APPROVED ontact Killark for FM file numbers. See files for details or call Killark. FEATURES-SPEIFIATIONS Applications Hazardous areas due to the presence of flammable gases or vapors, combustible dusts or easily ignitable fibers or flyings Installations at petroleum refineries, chemical and petrochemical plants, storage areas and other processing facilities where hazardous substances are handled or stored Full-voltage, across-the-line starting and stopping of polyphase A squirrel cage induction motors or as the primary starter for wound rotor motors Provides running and undervoltage protection of motor Remote starting and stopping of motor Features Rectangular bolted cover design provides for attractive, compact, uniform installations Ground flange joint between box and cover provides required flame path Two drilled and tapped power conduit openings, one top and one bottom are standard on all assemblies. One 3/4"-14 NPT drilled, tapped and plugged conduit opening is provided in bottom for remote control Two 3/4"-14 NPSM drilled, tapped, and plugged openings in cover are provided for addition of local control operator External reset button and stainless steel cover bolts are standard Hinges are either stainless steel or aluminum and are mounted on the left side of all assemblies Enclosure is cast copper-free aluminum alloy Available for utler-hammer AN16 Freedom or Square D 8536 starters Y7 MAGNETI LINE STARTER (ENLOSURES WITHOUT SPAE FOR ONTROL TRANSFORMER) NEMA MOTOR OIL MAXIMUM STARTER VOLTS VOLTS HP SIZE 0 Sep ontrol Sep ontrol / Sep ontrol Enclosure only No interior 1 Enclosure only No interior Enclosure only No interior Y7 MAGNETI LINE STARTER (ENLOSURES WITH SPAE FOR ONTROL TRANSFORMER) NEMA MOTOR OIL MAXIMUM STARTER VOLTS VOLTS HP SIZE 0 30// //5 1 30// ///10 30// //5 0 Enclosure only No interior 1 Enclosure only No interior Enclosure only No interior Overload Heaters Heaters not included. See page 59 for heater selection Dimensions See page 6 for dimensional data Modifications See page 6 UTLER-HAMMER SQUARE D SERIES AN16 SERIES 8536 Y7010BH Y7010BS Y7010DH Y7010DS Y7010KH Y7010KS Y7011BH Y7011BS Y7011DH Y7011DS Y7011KH Y7011KS Y701BH Y701BS Y701DH Y701DS Y701KH Y701KS Y7010ZH Y7010ZS Y7011ZH Y7011ZS Y701ZH Y701ZS UTLER-HAMMER SQUARE D SERIES AN16 SERIES 8536 Y7000BH Y7000BS Y7001BH Y7001BS Y700BH Y700BS Y7000ZH Y7000ZS Y7001ZH Y7001ZS Y700ZH Y700ZS

62 Y7 SERIES ONTROLS OMBINATION MOTOR STARTERS 61 lass I, Div. 1 &, Groups,D lass l, Zones 1 &, Groups llb, lla lass II, Div. 1 &, Groups E,F,G lass Ill NEMA 7(,D) 9(E,F,G) ertified - File LR11714 Y701ZHAZ FM APPROVED ontact Killark for FM file numbers. See files for details or call Killark. FEATURES-SPEIFIATIONS Applications Hazardous areas due to the presence of flammable gases or vapors, combustible dusts or easily ignitable fibers or flyings Full-voltage, across-the-line starting and stopping of polyphase A squirrel cage induction motors or as the primary starter for wound rotor motors Provides running and undervoltage protection of motor Motor branch circuit disconnect and short circuit protection Features Rectangular bolted cover design provides for attractive, compact, uniform installations Two 3/4"-14 NPSM drilled, tapped, and plugged openings are provided for addition of local operators Two drilled, tapped and plugged openings, one top and one bottom are supplied for installation of drain and breather Hinges are either stainless steel or aluminum and are mounted on the left side of all assemblies ircuit breaker handle mechanism interlocks with circuit breaker to prevent opening of enclosure when circuit is in the ON position External handle is vault type with standard provisions for locking in the OFF position with up to three padlocks ircuit breaker is trip free of handle mechanism Modifications Modifications are available. See page 6. Y7 OMBINATION MAGNETI LINE STARTER NEMA DISONNET MOTOR OIL MAXIMUM STARTER TRIP VOLTS VOLTS HP SIZE AMPS 0 Sep ontrol Sep ontrol Sep ontrol Sep ontrol Sep ontrol / Sep ontrol Sep ontrol Enclosure only. No Interior 1 Enclosure only. No Interior Enclosure only. No Interior Dimensions For dimensional data, see page 6. Overload Heaters Heaters are not included. See page 59 for heater selection. UTLER-HAMMER SQUARE D SERIES AN16 SERIES 8536 Y700BHVV Y700BSVV Y700BHVX Y700BSVX Y700BHVA Y700BSVA Y700DHVX Y700DSVX Y700DHVA Y700DSVA Y700KHVV Y700KSVV Y700KHVX Y700KSVX Y701BHVA Y701BSVA Y701BHV Y701BSV Y701DHV Y701DSV Y701KHV Y701KSV Y70BHVE Y70BSVE Y70BHVG Y70BSVG Y70DHVE Y70DSVE Y70DHVG Y70DSVG Y70KHVE Y70KSVE Y700ZHVZ Y700ZSVZ Y701ZHVZ Y701ZSVZ Y70ZHVZ Y70ZSVZ

63 6 Y7 SERIES ONTROLS MOTOR STARTERS/MODIFIATIONS ombination Starter Modifications Modifications are available by ordering the following by catalog number as separate items and noting on the order that they are to be assembled into the enclosure. FEATURES-SPEIFIATIONS Y7 MAGNETI LINE STARTERS DIMENSIONS NEMA A B D E G H J K ONDUIT SIZE SIZE POWER ONTROL /4"(197) 7-1/4"(184) 10"(54) 6"(15) "(51) 7-5/8"(194) 1-1/8"(8) 3/4"(19) 1-1/" 3/4" 1 9"(8) 7-3/4"(197) 11-1/4"(86) 6-1/"(165) "(51) 7-5/8"(194) 1-1/8"(8) 7/8"() 1-1/" 3/4" /4"() 11-1/8"(8) 1-1/"(317) 10-1/"(67) "(51) 8-1/4"(09) -3/8"(60) -3/8"(60) 1-1/" 3/4" 8-3/4"() 11-1/8"(8) 1-1/"(317) 10-1/"(67) "(51) 8-1/4"(09) -3/8"(60) -3/8"(60) 1-1/" 3/4" 1 Without space for control transformer. With space for control transformer. Y7 OMBINATION STARTERS DIMENSIONS NEMA A B D E G H J ONDUIT SIZE SIZE POWER ONTROL /4"(413) 11-1/8"(8) 0"(508) 10-1/"(67) "(51) 9"(8) -3/8"(60) 1-1/" 3/4" 16-1/4"(413) 11-1/8"(8) 0"(508) 10-1/"(67) "(51) 9"(8) -3/8"(60) 1-1/" 3/4" Dimensions Magnetic Line Starters Sizes 0, 1, Y7 MODIFIATIONS AND AESSORIES DESRIPTION GO-GR1D Double pushbutton (Start/Stop) GOB3-R3 N34 Red pilot light 10 Volt GOB3-G3 N34 Green pilot light 10 Volt GOB3-A3 N34 Amber pilot light 10 Volt B7PLR0 Pilot light resistor 0 Volt to 10 Volt B7PLR440 Pilot light resistor 440 Volt to 10 Volt B7PLR550 Pilot light resistor 550 Volt to 10 Volt GO5-A3F position selector switch (On/Off) GO5-33G 3 position selector switch (Hand/Off/Auto) B7HA utler-hammer auxiliary contact (1NO/1N) B7SA Square D auxiliary contact (1NO/1N) B7T50 ontrol transformer 50VA* B7T75 ontrol transformer 75VA* B7T100 ontrol transformer 100VA* KDB-1 Breather KDB-1 Drain KIT-51 Grounding kit * ontrol transformers are primary 40/480 - Secondary 10 Volt. * All control transformers include fused primary and secondary circuits. ombination Starters Sizes 0, 1,

64 Y7 SERIES ONTROLS MANUAL MOTOR STARTING SWITHES 63 lass I, Div. 1 &, Groups,D lass 1, Zones 1 &, Groups llb, lla lass II, Div. 1 &, Groups E,F,G lass Ill NEMA 7(,D) 9(E,F,G) NEMA 3 (Factory sealed type) Listed - File E53360 and/or E1379 ertified - File LR11714 XSD, XSX, Series Non Factory Sealed FXSD, FXSX Series Factory Sealed FM APPROVED FM File 519 See files for details or call Killark. FEATURES-SPEIFIATIONS Applications Provides manual starting and stopping of small A or D motors Motor running protection when overload heaters are used XSX/FXSX Series (without overload protection) are ideally suited for across-the-line applications where a positive disconnect means is required Features FXSX-FXSD Series require no external seals (factory sealed) and are NEMA 3 (raintight) rated Enclosures are cast copper-free aluminum alloy Operating shaft is stainless steel Multiple gang assemblies available in combination with pilot lights, pushbuttons and switches on request Ground flange joint between bolted cover and box provide required flame path Provisions for padlocking switch in either ON or OFF position is standard Dimensions For dimensional data, see page 64. XSD/FXSD SERIES WITH OVERLOAD PROTETION1 Non-Factory Sealed: Square D, lass 510, Type F 1-Pole, 1HP, VA -Pole, 1HP, VA 3/4 HP, VA XSD SINGLE GANG 1-POLE -POLE HUB HUB SINGLE SINGLE STYLE SIZE PHASE PHASE XSD-11 XSD-1 Dead 1/" XSD-1 XSD- end 3/4" XSD-41 XSD-4 Feed 1/" XSD-51 XSD-5 thru 3/4" XSD-01 XSD-0 over and Switch assembly 1 Order heaters separately on page 64. XSX/FXSX SERIES WITHOUT OVERLOAD PROTETION Non-Factory Sealed: Square D, lass 510, Type K -Pole, HP, 115 VA HP, VA 3 HP, VA 3-Pole, HP, 115 VA 7-1/ HP, VA 10 HP, VA Factory Sealed: Square D, lass 510, Type F 1-Pole, 1HP, VA -Pole, 1HP, VA 3/4 HP, VA FXSD SINGLE GANG 1-POLE -POLE HUB HUB SINGLE SINGLE STYLE SIZE PHASE PHASE FXSD11 FXSD1 Dead 1/" FXSD1 FXSD end 3/4" FXSD41 FXSD4 Feed 1/" FXSD51 FXSD5 thru 3/4" FXSD01 FXSD0 over and Switch assembly Factory Sealed: Square D, lass 510, Type K -Pole, HP, 115 VA HP, VA 3 HP, VA 3-Pole, HP, 115 VA 3 HP, VA 5 HP, VA XSX SINGLE GANG -POLE 3-POLE HUB HUB 30A., 50V 30A., 50V STYLE SIZE 0A., 600V 0A., 600V 1-PHASE 3-PHASE XSX-1 XSX-13 Dead 1/" XSX- XSX-3 end 3/4" XSX-4 XSX-43 Feed 1/" XSX-5 XSX-53 thru 3/4" XSX- XSX-3 over and Switch assembly FXSX SINGLE GANG -POLE 3-POLE HUB HUB 30A., 50V 30A., 50V STYLE SIZE 0A., 600V 0A., 600V 1-PHASE 3-PHASE FXSX1 FXSX13 Dead 1/" FXSX FXSX3 end 3/4" FXSX4 FXSX43 Feed 1/" FXSX5 FXSX53 thru 3/4" FXSX0 FXSX03 over and Switch assembly

65 64 XSD/XSX/FXSD/FXSX SERIES ONTROLS XSD/XSX/FXSD/FXSX HEATERS HEATER TABLE1 SQUARE D FULL-LOAD ATALOG HEATER MOTOR NUMBER ATALOG URRENT NUMBER YOSD-A A.49 YOSD-A A.54 YOSD-A A.59 YOSD-A A.65 YOSD-A A.71 YOSD-A A.78 YOSD-A A.86 YOSD-A A.95 YOSD-A A1.0 YOSD-A A1.16 YOSD-A A1.5 YOSD-A A1.39 YOSD-A A1.54 YOSD-A A1.63 YOSD-A A1.75 YOSD-A A1.86 YOSD-A A1.99 YOSD-A A.15 YOSD-A A.31 YOSD-A A.57 YOSD-A A.81 YOSD-A A3.61 YOSD-A A3.95 YOSD-A A4.3 YOSD-A A4.79 YOSD-A A5.30 YOSD-A A5.78 YOSD-A A6.0 YOSD-A A6.99 YOSD-A A7.65 YOSD-A A8.38 YOSD-A A9.5 YOSD-A A9.85 YOSD-A A11.0 YOSD-A A11.9 YOSD-A A13. YOSD-A A14.1 YOSD-A A14.8 YOSD-A A16. YOSD-A A17.9 YOSD-A A19.8 YOSD-A A1.3 YOSD-A A5. FEATURES-SPEIFIATIONS XSD/XSX NON-FATORY SEALED DIMENSIONS BOX STYLE HUB SIZE A B D G 1/" 5-1/4"(133) -1/4"(57) 11/16"(17) Single gang dead-end 3/4" 5-1/4"(133) -1/4"(57) 11/16"(17) 1" 5-3/8"(136) -3/8"(60) 7/8"() 1/" 5-1/4"(133) -1/4"(57) 6"(15) 11/16"(17) Single gang feed-thru 3/4" 5-1/4"(133) -1/4"(57) 6"(15) 11/16"(17) 1" 5-3/8"(136) -3/8"(60) 6"(15) 7/8"() FATORY SEALED (FXSD/FXSX) 1Overload heaters are not supplied as part of the starter assemblies and need to be ordered as separate items by catalog number and priced accordingly.

66 XMSW SERIES ONTROLS MANUAL LINE STARTERS 65 UTLER HAMMER/EATON B100 STARTERS FULL VOLTAGE, NON-REVERSING SINGLE AND POLYPHASE Applications XMSW Series, non-reversing, manual line voltage starters and enclosures are suitable for use in applications requiring manual across-the-line starting and stopping of small single and polyphase A motors, and where overload protection is needed. Manual starters are generally used on small machine tools, fans and blowers, pumps, compressors, and conveyors as well as many lass I, Div. 1 &, Groups,D lass l, Zones 1 &, Groups llb, lla lass II, Div. 1 &, Groups E,F,G lass Ill NEMA 3R, 7(,D) 9(E,F,G) Listed - File E1379 See files for details or call Killark. FEATURES-SPEIFIATIONS other types of electrical machinery. Features Rectangular bolted cover design provides for attractive, compact, uniform installations Enclosure and external handle are diecast copper-free (less than 0.4%) aluminum alloy ast ON, OFF, TRIPPED markings on cover align with external handle and provide clear indication of enclosed starter condition External handle is a vault type with standard provisions for locking in the OFF position with up to three padlocks. Provision for locking in ON position is available as factory modification (add suffix SU-40 to catalog number). Two cast 1" NPT conduit hubs with integral pipe stop, one top and one bottom, are standard on all assemblies Electrical Rating Starter sizes 0, 1, 11/ Two pole, single phase; three pole, Dimensions 1 Select heater element based on motor nameplate listed. Full-load amps. Trip rating of element is 15% of motor minimum F.L.A. listed for the element. XMSW MANUAL LINE STARTERS1 NEMA NUMBER OF MAXIMUM HORSEPOWER SIZE POLE SIZE 10 VA VA VA 0 -POLE; 1Ø, A POLE; 3Ø, A POLE; 1Ø, A POLE; 3Ø, A 3 7-1/ / -POLE; 1Ø, A Heaters not included. If heaters are required order as separate item by catalog number, three phase starters require three heaters. Single phase starters require two heaters. Three pole starters may be used on two-phase four-wire circuits by running one wire direct to motor. YOWEA00-FH FH03 YOWEA00-FH FH04 YOWEA00-FH FH05 YOWEA00-FH FH07 YOWEA00-FH FH07 YOWEA00-FH FH08 YOWEA00-FH FH09 YOWEA00-FH FH10 YOWEA00-FH FH11 YOWEA00-FH FH1 YOWEA00-FH FH13 YOWEA00-FH FH14 YOWEA00-FH FH15 YOWEA00-FH FH16 YOWEA00-FH FH17 YOWEA00-FH FH18 YOWEA00-FH FH19 YOWEA00-FH FH0 YOWEA00-FH FH1 YOWEA00-FH FH YOWEA00-FH FH3 YOWEA00-FH FH4 YOWEA00-FH FH5 YOWEA00-FH FH6 YOWEA00-FH FH7 YOWEA00-FH FH8 YOWEA00-FH FH9 WITH ENLOSURE STARTER ONLY XMSW-0BT XMSW-0T XMSW-1BT XMSW-00T XMSW-1T XMSW-DBT HEATER TABLE FOR XMSW SERIES MANUAL LINE STARTERS1 MOTOR FULL-LOAD 40 O WESTING- ATALOG SINGLE THREE HOUSE ATALOG NUMBER PHASE PHASE ODEMARK NUMBER MOTOR FULL-LOAD 40 O WESTING- SINGLE THREE HOUSE PHASE PHASE ODEMARK YOWEA00-FH FH30 YOWEA00-FH FH31 YOWEA00-FH FH3 YOWEA00-FH FH33 YOWEA00-FH FH34 YOWEA00-FH FH35 YOWEA00-FH FH36 YOWEA00-FH FH37 YOWEA00-FH FH38 YOWEA00-FH FH39 YOWEA00-FH FH40 YOWEA00-FH FH41 YOWEA00-FH FH4 YOWEA00-FH FH43 YOWEA00-FH FH44 YOWEA00-FH FH45 YOWEA00-FH FH46 YOWEA00-FH FH47 YOWEA00-FH FH48 YOWEA00-FH FH49 YOWEA00-FH FH50 YOWEA00-FH FH51 YOWEA00-FH FH5 YOWEA00-FH FH53 YOWEA00-FH FH54 YOWEA00-FH FH55 YOWEA00-FH FH56 YOWEA00-FH FH57

FACTORY SEALED CONTROLS - INTRODUCTION

FACTORY SEALED CONTROLS - INTRODUCTION FACTORY SEALED - INTRODUCTION Contact Factory for other certification details D2CU Factory Sealed Contact Block Applications Seal-XM Factory Sealed push button stations, selector switches, pilot lights

More information

FACTORY SEALED CONTROLS - INTRODUCTION

FACTORY SEALED CONTROLS - INTRODUCTION FACTORY SEALED - INTRODUCTION Contact Factory for other certification details D2CU Factory Sealed Contact Block Applications Seal-XM Factory Sealed push button stations, selector switches, pilot lights

More information

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

HKH Series. HAZCON Controls for Harsh and Hazardous Environments HKH Series HAZCON Controls for Harsh and Hazardous Environments Z A H LO C NON-METALLIC DIN RAIL MOUNT Component Mounting Rail Optional Customer I.D. Nameplate Optional Legend Plate Explosion Protective

More information

STAINLESS STEEL PANEL MOUNT

STAINLESS STEEL PANEL MOUNT Z A H LO C STAINLESS STEEL PANEL MOUNT Optional Legend Plate Cover Screw Retaining Washer Panel Mount Bracket Explosion Protective LED Pilot Light Stainless Steel Washer Actuator Spacer Locknut Explosion

More information

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed

More information

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY EDSC210 -Way Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type Contact Configuration Current Rating Voltage Rating Material, Color, and

More information

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY EDS2274 Pos D.E. Selector Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type SINGLE GANG Contact Configuration 4NO-4NC Number of Circuits

More information

GHG43 Series Control Stations

GHG43 Series Control Stations GHG43 Series Control Stations Nonmetallic or 316L Stainless Steel UL/cUL listed Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zones 1 and 2, (A) Ex de IIB + H2 T6 Cl. II, Div. 1, Groups E, F, G (cul) PTB ATEX

More information

Hazardous Factory Sealed Control Devices

Hazardous Factory Sealed Control Devices Hazardous Factory Sealed Control Devices Description Page No. Application/Selection 428, 429 Dimensions 40 Manual Motor Starting Switches & Enclosures EDS Series 440, 44 Pilot Lights EFS Series 45 Pilot

More information

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures

More information

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

HKH Series. HAZCON Controls for Harsh and Hazardous Environments (93) A ø 0.2" (ø 5.5) 1.9 (4 3.7" (93) B A " 0) 8" 0) HKH Series HAZCON Controls for Harsh and Hazardous Environments 0.2" (5.5) 0.2" (5.5) 3.1" (80) 2.8" (70) ø 0.2" (ø 5.5) 1.9" (48) 3.7" (93) A B 0.2"

More information

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA) 804 South Street 75964-726, TX Nacogdoches Phone: 96-569-794 Fax: 96-560-4685 EDS25 -Gang Start/Stop Station Cooper Crouse-Hinds Catalog Number Manufacturer Weight per unit Product Category Features Assembly/Kit

More information

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. &, Groups B*, C, D Cl. II, Div., Groups E, F, G Cl. II, Div., Groups F, G NEMA, 7B*CD, 9EFG Applications:

More information

Contender Series Factory Sealed Control Stations and Pilot Lights Explosionproof, Dust-Ignitionproof Furnished with Internal Ground Screw.

Contender Series Factory Sealed Control Stations and Pilot Lights Explosionproof, Dust-Ignitionproof Furnished with Internal Ground Screw. Contender Series Factory Sealed Control Stations and Pilot Lights Furnished with Internal Ground Screw. Applications Push buttons and selector switches are used in conjunction with contactors or magnetic

More information

Spring-loaded cover seats against neoprene gasket.

Spring-loaded cover seats against neoprene gasket. U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Plugs

More information

ACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS

ACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS Z A H LO C ACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS BASIC CATALOG NUMBERS HKHPBMMSS1 HKHPBMMTC1 HKHPBILLMM1 HKHPBMMMR1 HKHPBMMMB1 HKHPBMMMG1 HKHDBLPBMMGR1 HKHPBPMTMR1 HKHPBPMTMB1 HKHPBPMTMG1 HKHPBTMTMR1

More information

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket. U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Applications

More information

Applications. Separate sealing chamber and switch construction. Used on 20 Amp 4-way and all 30 Amp models.

Applications. Separate sealing chamber and switch construction. Used on 20 Amp 4-way and all 30 Amp models. Contender Series Factory Sealed Front Operated Tumbler Switches Malleable Iron Body and Cover. Furnished with Internal Ground. NEMA 3, 7CD, 9EFG Applications Designed to prevent arcing of enclosed switches

More information

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket. U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Applications

More information

Junction boxes for control, monitoring and control panel Ex tb

Junction boxes for control, monitoring and control panel Ex tb Junction boxes for control, monitoring and control panel - Zone 21, 22 - Category 2D - Aluminium, reinforced polyester or stainless steel enclosures - Standard or custom products Inspection window Padlockable

More information

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit. EDS Factory Sealed Tumbler Switches UNILETS for Use with Threaded Metal Conduit. Class I, Division 1 and 2, Groups B, C, D NEMA 7 B CD, 9EFG Applications Designed to prevent arcing of enclosed switches

More information

Plugs and Receptacles: Hazardous Location

Plugs and Receptacles: Hazardous Location U-Line Factory Sealed 15 and 20 Amp Plugs and Receptacles V Plugs and Receptacles Plugs and Receptacles: Hazardous Location Applications Locations where receptacles are used with stationary or portable

More information

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit. UNILETS for Use with Threaded Metal Conduit. Class I, Division 1 and 2, Groups B, C, D Applications Designed to prevent arcing of enclosed switches in ignitable atmospheres during connect and disconnect

More information

EXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

EXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments EXBLI & EXBSPI Series Circuit Breaker Panelboards for Harsh and Hazardous Environments KILLARK Z A H LO C NEMA 4X O Ring Gasket Stainless Steel Tri-Lead Cover New Slide MCB Assembly Handles Padlockable

More information

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments D2LC Series Circuit Breaker Panelboards for Harsh and Hazardous Environments IBUTI TR HA ON DIS KILLARK Z LO C Type 4X Gasket Stainless Steel Tri-Lead Cover Bolts Spare Sealed Wires Termination at Terminal

More information

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33 SECTION V INDEX Product Description Page Number Junction Boxes......................................V-V2 Meter and Instrument Enclosures.......................V24-V Control Centers.....................................V4-V9

More information

Standard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat

Standard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat U-Line Factory Sealed 15 and 20 Amp Plugs and Receptacles V Applications Locations where receptacles are used with stationary or portable electrically operated devices such as: Lighting systems Conveyors

More information

CIRCUIT BREAKER PANELBOARDS

CIRCUIT BREAKER PANELBOARDS CIRCUIT BREAKER PANELBOARDS Class l, ones 1 & 2, Groups llb+h 2 Certified File LR 11713 for B7L FEATURES-SPECIFICATIONS Applications Hazardous locations due to the presence of flammable gases or vapors,

More information

Contactors & Starters Index

Contactors & Starters Index ontactors & Starters Index NEMA ontrol Description Page Number General Information - HP... A Magnetic ontactors - HP...4 A Magnetic Reversing ontactors - HP... 4 A Magnetic Starters - HP... A Magnetic

More information

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof Class I, Groups C, D Class I, Division 2, Group B Class I, Zone 1, Group IIB Class I, Zone 2, Group IIB +

More information

CONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES. Applications. Illustrated Features

CONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES. Applications. Illustrated Features Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground. Applications Designed to prevent arcing of enclosed switches in ignitable atmospheres during connect and

More information

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles ENR Value Series Dead Front Interlocked Circuit Breaking s Cl. I, Div. & 2, roups B, C, D Cl. II, Div. & 2, roups F, Cl. III, 7BCD, 9F, 2 Dust-Ignitionproof Raintight et Locations ENP Plugs Applications:

More information

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

Circuit Breakers. Switching & Controls.  Selection Guide NC1V Series Dimensions... Switching & ontrols Selection Guide... 1028 1V Series... 1029 Dimensions... 1035 www.ide.com/circuitbreaker ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal

More information

Explosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC

Explosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC 9419 E US HWY 175, Kemp, TX 75143 Phone: 1 8003696671 Fax: 903.498.3364 Email: sales@larsonelectronics.com Explosion Proof Receptacle Integral Circuit Breaker Class 2 Division 1 30 Amp 480VAC Part #: EPO3W4P30AICB

More information

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw. Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw. Applications Designed to prevent arcing of enclosed switches in ignitable atmospheres during connect

More information

Motor Starters Hazardous and Non-Hazardous

Motor Starters Hazardous and Non-Hazardous Motor Starters Hazardous and Non-Hazardous Description Page No. Application/Selection 342 Magnetic Line Starters & Enclosures Single speed, non-reversing EBMS Series 343-346 EPC Series 349-351 EBMS Series

More information

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous Description Page No. Application/Selection 1000, 1001 Arktite Delayed Action Circuit Breaking Technical Data 1002, 1003 20 & 30A CPS Receptacle

More information

Control Stations Hazardous and Non-Hazardous

Control Stations Hazardous and Non-Hazardous Control Stations Hazardous and Non-Hazardous Description Page No. Application/Selection 384, 385 Controls for Bulk Solids Handling AFA/AFAX Conveyor Alignment Switches 417 AFU/AFUX Conveyor Control Safety

More information

Series 70 Electric Actuator

Series 70 Electric Actuator Series 70 Electric Actuator SERIES 70 RUGGED electric actuator FOR ROTARY VALVES 300 to 18,000 lb-in Output torque Bray ontrols years of proven success in electric actuation, combined with innovative engineering,

More information

ø8 A8 Series Miniature Control Units

ø8 A8 Series Miniature Control Units A8 ø8 A8 Series Miniature Control Short 22-mm-long body miniature control unit series with LED illumination face and snap-action switching. Bright and clear LED illumination. All series have terminals

More information

Miniature Switches & Pilot Devices

Miniature Switches & Pilot Devices A8 Series Miniature Switches and Pilot Devices: 8mm Key features of the 21/64" (8mm) A8 series Switches and Pilot Devices include: 21/64" (8mm) round mounting hole Compact Design Saves Space Bright and

More information

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System NEC/ Applications Protection and control of electrical apparatus and circuits in hazardous environments, either indoor or outdoor. Designed for Class I, Division 2 areas where flammable gases or vapors

More information

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS FACTORY SEALED CIRCUIT BREAKER BOARDS Applications Hazardous areas due to the potential of explosive gas atmospheres, combustible dusts or easily ignited fibers or flyings and areas subjected to corrosive

More information

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories Switching & ontrols Selection Guide... 922 1V Series... 923 Dimensions... 929 Accessories... 932 ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks

More information

Distinctive Characteristics

Distinctive Characteristics Distinctive haracteristics arefully designed light diffusion and filtering system produces bright, full surface illumination with front panel relamping. Spot illumination available in single and bicolor

More information

Arktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed

Arktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed Arktite Circuit Breaking CPS Application: CPS receptacles, angle and straight types, and CPP plugs are used: with portable electrically operated devices such as motor-generator sets, compressors, conveyors,

More information

Panelboards & Motor Starters

Panelboards & Motor Starters Appleton s ATX series of Increased Safety distribution panels are available in IP66-rated fiberglass reinforced polyester (FRP) or 316L stainless steel and come in multiple sizes depending on the number

More information

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw. EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw. Controls CONTROLS: HAZARDOUS LOCATION CONTROL STATIONS AND SWITCHES

More information

Switches & Pilot Devices

Switches & Pilot Devices ø16mm - A6 Series A6 Series Miniature Switches and Pilot Devices: 16mm Key features: 16mm (/8 ) mounting hole ED illumination ompact design saves space Momentary, Maintained, Selectors, and E-Stops Gold-clad

More information

PlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures

PlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures Applications The PlexPower panelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as: Petroleum plants Chemical plants Refineries Wastewater

More information

8146 Series F16 CONTROLS CONTROL STATION IN POLYESTER RESIN. Features: Components:

8146 Series F16 CONTROLS CONTROL STATION IN POLYESTER RESIN. Features: Components: 8146 Series ONTROLS ONTROL STTION IN POLYESTER RESIN LSSIFITIONS NE- lass I, Zones 1 & 2 Ex e II T6 lass I, ivision 2, Groups,,, lass II, ivision 2, Groups F,G lass III NEM 3,4 & 4X; IP66 LISTE - FILE

More information

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753 Depth x  Width x 2.375 Height 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 7842 40A 600V 2P Switch Pass & Seymour/Legrand Catalog Number 7842 Manufacturer Pass & Seymour/Legrand Weight per unit

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits

More information

8146 Series Terminal Boxes

8146 Series Terminal Boxes 8146 Series Terminal oxes TERMINTION Ready-Term 8146 Terminal oxes Features: Pre-onfigured with terminals mounted Made of Fiberglass Reinforced Polyester (FRP) 8 enclosure sizes with different depths For

More information

Switches & Pilot Devices

Switches & Pilot Devices ø16mm - 6 Series Key features: 5/8 (16mm) mounting holes ocking lever removable contact blocks Solder terminal or PB terminal options Available assembled or as sub-components Worldwide approvals Incandescent

More information

Division 2 Contender Series Factory Sealed Control Stations

Division 2 Contender Series Factory Sealed Control Stations NEMA 3, 3R, 4, 4X, 12 IP66 Applications For use in washdown areas and other damp, wet and highly corrosive areas. Push buttons and selector switches are used in conjunction with contactors or magnetic

More information

Electric Fail-Safe. Actuators. Spring Return. Electric Fail-Safe. Battery Backup. Mechanical failure torques up to 2300 in-lbs.

Electric Fail-Safe. Actuators. Spring Return. Electric Fail-Safe. Battery Backup. Mechanical failure torques up to 2300 in-lbs. Electric Fail-Safe Actuators Spring Return Electric Fail-Safe Mechanical failure torques up to 2300 in-lbs. Battery Backup Electric Fail-Safe Torques up to 2640 in-lbs. Emergency shutdown applications

More information

PlexPower Factory Sealed Panelboard 15 to 150 Amps. Stainless Steel Enclosures

PlexPower Factory Sealed Panelboard 15 to 150 Amps. Stainless Steel Enclosures Applications The PlexPower panelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as: Petroleum plants Chemical plants Refineries Wastewater

More information

GE 8000-Line Motor Control Centers Mains, Feeders, Incoming Lines C-1

GE 8000-Line Motor Control Centers Mains, Feeders, Incoming Lines C-1 GE 8000-Line -1 Mains, coming Lines MAINS GENERAL Main units consist of an externally operable circuit disconnect, either a fusible switch or a circuit breaker. Sizes by ampere rating, short-circuit rating,

More information

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.

More information

ø10 A1 Series Miniature Control Units

ø10 A1 Series Miniature Control Units A1 ø10 A1 Series Miniature Control Short 22-mm-long body miniature control unit series with LED illumination face and snap-action switching. Bright and clear LED illumination. All series have terminals

More information

Standard Materials Bodies and covers: copper-free aluminum.

Standard Materials Bodies and covers: copper-free aluminum. -26 AEB Series: Bolted Combination and Non-Combination Full Voltage Motor Starters: Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. Application Combination and

More information

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this

More information

General Specifications

General Specifications Standard Size Pushbuttons General Specifications Electrical apacity (Resistive Load) Power Level (silver): 3A @ 125V A or 3A @ 250V A or 3A @ 30V Logic Level (gold): 0.4VA maximum @ 28V A/ maximum (Applicable

More information

Quartz Explosionproof valve monitoring

Quartz Explosionproof valve monitoring Quartz Explosionproof valve monitoring The Quartz is available in explosionproof (QX), nonincendive, intrinsically safe (QN), and general purpose (QG) versions. The robust epoxy-coated anodized aluminum

More information

Oiltight Switches & Pilot Devices

Oiltight Switches & Pilot Devices Oiltight Switches & Pilot Devices HW Series 22mm IEC Style Global Pushbuttons Circuit Breakers Terminal Blocks Timers Relays & Sockets Display Lights Switches & Pilot Lights Key features include: Locking

More information

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute RA Series RA Series RAS RA Key features of the RA series include: Available in 4 different styles Excellent overload and short circuit protection Small size and high-efficiency Life expectancy of over

More information

TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS

TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS OSUR CL HA ES EN KILLARK Z LO C SJIC SERIES TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS Screw cover style, with or without continuous hinge 3/16 (5mm) wide flat flange for maximum gasket surface

More information

Non-illuminated Push Buttons

Non-illuminated Push Buttons Non-illuminated Push Buttons 3 Accessories for push buttons Lockout attachment Contact block kits Lens kits Wobblestick kit Push Button Cap Interchangeable, snap-in design Protective caps 9 colors: red,

More information

Contacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Low energy contacts gold plated. Minimum PUSHBUTTON

Contacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Low energy contacts gold plated. Minimum PUSHBUTTON Pilot Devices Technical data UL General UL technical data Contact blocks Rated insulation voltage, UL 600V Rated thermal current 10A / 600VAC 2.5A / 600VDC Minimum rating 24VDC, 5mA Mechanical life (millions

More information

Presentation, Application Severe Duty Limit Switches Mill and Foundry Switches Conforming to NEMA A600 and UL508

Presentation, Application Severe Duty Limit Switches Mill and Foundry Switches Conforming to NEMA A600 and UL508 Presentation, pplication Severe uty Limit Switches 0 onforming to NEM 600 and UL508 escription 9007T Mill Switches Use the 9007T Mill switches instead of other limit switches in the following applications:

More information

Bright illumination face and snap-action switching.

Bright illumination face and snap-action switching. ø A2 Series ø10 A1 Series ø8 A8 Series A2 Series A1 Series A8 Series Bright illumination face and snap-action switching. See website for details on approvals and standards. Hole Size Model Function Degree

More information

10 Load and Motor Switchgear

10 Load and Motor Switchgear 0 Load and Motor Switchgear Motor Protection ircuitbreakers For use in Zone and Zone Zone and Zone For protection of Ex e and Ex d motors Protects cables and plant equipment Adjustable thermal overcurrent

More information

Product Guide. enclosed NEMA STARTERS

Product Guide. enclosed NEMA STARTERS Product Guide enclosed NEMA STARTERS The Right Choice for Applications that Demand the Best. Siemens NEMA Combination and Non- Combination Starters for Industrial and Construction Applications Rugged,

More information

150 C 30 F B D 8L 152H C 30 F BD 43 8L

150 C 30 F B D 8L 152H C 30 F BD 43 8L SM - Smart Motor ontrollers atalog Number Explanation Open and Non-ombination F D L a b c d e f g a ulletin Number ode Solid-State ontroller b ontroller Type ode SM- c Ampere s ode A A A A A A A A A A

More information

LW Series offer flexibility in space-saving package

LW Series offer flexibility in space-saving package ourtesy of Steven Engineering, Inc. 230 yan Way, South San Francisco,, 94080-6370 Main Office: (650) 588-9200 Outside Local rea: (800) 258-9200 www.steveneng.com LW Series offer flexibility in space-saving

More information

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism

More information

Covers for Cast Iron or Aluminum Device Boxes

Covers for Cast Iron or Aluminum Device Boxes Single Gang Blank cover for enclosing splices and taps where device not used. Sheet DS100 Flush Sheet steel DSS100 For GFI receptacles. Sheet steel DS23 GFI For square handle general use snap or toggle

More information

Poppet Valves Series

Poppet Valves Series Poppet Valves 750 Series ontents Section Page Introduction 750 Series Poppet Valve Pilot operated 4 /4 to / Pilot operated 5 /4 to Pilot operated 6 Pilot operated 7 /4 to / Pilot solenoid operated 8 /4

More information

ICG Switchgear Price List 2009

ICG Switchgear Price List 2009 ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section

More information

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in

More information

Mid-West Instrument. Bellows Type Differential Pressure Gauges & Switches Model s 105 & 106

Mid-West Instrument. Bellows Type Differential Pressure Gauges & Switches Model s 105 & 106 Bellows Type Differential Pressure Gauges & Switches Model s 105 & 106 Dry Gauge Design with No Internal Liquid Fill BULLETIN NO. 105-106/12 (SUPERSEDES 105-106/11) Industrial ontrol Over Range Protection

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

UniCode Series Factory Sealed Control Stations and Pilot Lights

UniCode Series Factory Sealed Control Stations and Pilot Lights Applications For use in hazardous areas as defined by the National Electrical Code (NEC), and Canadian Electrical Code (CEC). For use in washdown areas and other damp, wet and highly corrosive areas. Push

More information

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry See NEW information on Class 82 size 1 in an extra wide enclosure and size 2 standard enclosures. usa.siemens.com/controls

More information

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B) 4 Engineering Information Principles of Operation A solenoid valve is a combination of two basic functional units: A solenoid (electromagnet) with its core A valve body containing one or more orifices

More information

194R J S TY N1

194R J S TY N1 Bulletin R IE Fused and Non-Fused Disconnects, & A Product Selection omplete UL/SA Disconnect Switch Kits Includes disconnect switch, operating handle with defeater mechanism and operating shaft, NFPA

More information

188 Dimensions: Inches [mm] In-line Version Solenoid valves assembled to manifolds ( Normally closed, orifice only. onsult ASO for alternative c

188 Dimensions: Inches [mm] In-line Version Solenoid valves assembled to manifolds ( Normally closed, orifice only. onsult ASO for alternative c The 188 is a 3 Way, 10 mm wide micro solenoid valve designed to be used in fluid power applications. Using air or other neutral gasses the 188 can be used to pilot other valves or cylinders. ompact manifold

More information

ø12 A2 Series Miniature Control Units

ø12 A2 Series Miniature Control Units ø2 A2 Series Miniature Control Short 22-mm-long body miniature control unit series with bright LED illumination face and snap-action switching. Degree of protection: IP40 and IP5 (IEC 0529) All series

More information

EIC combination motor starters

EIC combination motor starters pplications: Harsh and hazardous motor control environments, including refineries, chemical and petrochemical plants, corrosive process facilities, food and beverage, marine and mining cross-the-line starting

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction K Pressure Controller Cataloge Code Characteristics Index K00-2 Pressure Controller Brief Introduction KC32 Screw Tube Differential Pressure Controller K01 KY10 Bellows Type Differential Pressure Controller

More information

Product guide. Enclosed NEMA starters. usa.siemens.com/controls

Product guide. Enclosed NEMA starters. usa.siemens.com/controls Product guide Enclosed NEMA starters usa.siemens.com/controls The right choice for applications that demand the best Siemens NEMA combination and non-combination starters for industrial and construction

More information

Eclipse Compact and modular with solid state reliability

Eclipse Compact and modular with solid state reliability Eclipse ompact and modular with solid state reliability StoneL s Eclipse features dual solid state sensors with optional communications neatly integrated into a sealed module. The function module and trigger/indicator

More information

KEMLUXIII KH SERIES HAZARDOUS LOCATION

KEMLUXIII KH SERIES HAZARDOUS LOCATION KEMLUXIII SERIES HAZARDOUS LOATION AT.# APPROVALS JOB TYPE SPEIFIATIONS Applications - Designed to efficiently light corrosive and harsh applications such as chemical, petrochemical, marine, power generation,

More information

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AP20467S22 3W-4P 200A Plug Cooper Crouse-Hinds Catalog Number AP20467S22 Manufacturer Cooper Crouse-Hinds Description

More information

Product guide. Enclosed NEMA starters. Answers for industry.

Product guide. Enclosed NEMA starters. Answers for industry. Product guide Enclosed NEMA starters Answers for industry. The right choice for applications that demand the best Siemens NEMA combination and non-combination starters for industrial and construction applications

More information

P-2 ccsaus, curus Class I Div. 2 Group B,C, D Class I Zone 1 AEx de IIB+H 2 T6 Ex d IIB+H 2 T6 U Type 4X, IP66

P-2 ccsaus, curus Class I Div. 2 Group B,C, D Class I Zone 1 AEx de IIB+H 2 T6 Ex d IIB+H 2 T6 U Type 4X, IP66 -2 ccsaus, curus Class I Div. 2 Group B,C, D Class I Zone 1 AEx de IIB+H 2 T6 Ex d IIB+H 2 T6 U Type 4X, I66 owerlex anelboards: Steel Enclosures Applications The owerlex anelboard provides indoor and

More information