Installation and Operation Instructions. VAG ROTOP Portable Electric Drive

Size: px
Start display at page:

Download "Installation and Operation Instructions. VAG ROTOP Portable Electric Drive"

Transcription

1 Installation and Operation Instructions VAG ROTOP Portable Electric Drive KAT-B 5551 Edition 1-01/2018

2 Content 1 General Safety Proper use 3 2 Transport and Storage Transport Storage 3 3 Product features Features and function description Fields of application Performance limits Proper and improper mode of operation 4 VAG reserves the right to make technical changes and use materials of similar or better quality without express notice. The pictures are non-binding. 4 Set-up and operation Visual inspection and preparation Set-up and operation Adjusting the speed Adjusting the torque Important note about torque shut-off! Adjusting the direction of rotation The counter Starting the VAG ROTOP Operation 6 5 Maintenance and repair General safety instructions Inspection and operation intervals 7 6 Trouble-shooting 7 7 How to contact us 7

3 1 General 1.1 Safety These Operation and Maintenance Instructions must be observed and applied at all times along with the general for Valves (see / Category: Installation and Operation Instructions). Arbitrary alterations of this product and of the parts and accessories supplied with it are not allowed. VAG does not assume any warranty or liability for consequential damage arising from noncompliance with these instructions. When using this drive, the generally acknowledged rules of technology have to be observed (e.g. DIN standards, DVGW data sheets, VDI directives, etc.). The installation may only be carried out by qualified staff (see also Section 7.1 General safety instructions). For further technical information such as dimensions, materials or applications, please refer to the respective documentation (KAT-A 5551). The VAG ROTOP is designed and manufactured to the state of the art and its safety of operation is ensured in general. However, the VAG ROTOP may be potentially dangerous if it is operated improperly or is not applied for the intended use. Everyone dealing with the assembly, disassembly, operation, maintenance and repair of the valves must have read and understood the complete Operating and Maintenance Instructions (Accident Prevention Regulations, VBG 1 14 ff and following). The operator must have a strong foothold when operating the valve with the VAG ROTOP. When using the VAG ROTOP great care must be taken that the end positions of the valve are approached slowly. Make sure to watch the display. Any sudden stop would otherwise threaten to turn the drive as well. Make sure to observe when in operation: For reasons of safety only adjust the torque and direction of rotation switch when shut down. To prolong the service life of the valve and the drive, always operate at the lowest possible torque. To avoid overloads to the valve and the drive, moving to end position must not be dependent on the torque, but the path, while watching the counter. Even with power switched off the drive will continue to turn until operating power has been completely dissipated. Use the supplied actuator column to give the operator a firm foothold, especially for stiff valves. For equipment for which monitoring is mandatory, the relevant laws and regulations such as the Industrial Code, Accident Prevention Regulations, VDE Guidelines, AD Data Sheets (AD = Boiler Study Group), etc. must be complied with. In addition to this, local accident prevention regulations must be complied with. 1.2 Proper use The VAG ROTOP is a portable electric drive. It is suitable for easily and ergonomically operating valves. For technical data concerning the operating limits such as medium or temperature, please refer to document KAT 5551-A. Any deviating operating conditions and applications require the manufacturer s prior written consent! These Installation and Operation Instructions contain important information on the safe and reliable operation of the VAG ROTOP. Observing these Operation and Maintenance Instructions helps you to: Prevent hazards Reduce repair costs and down-times of the drive and/or the complete system Improve the operational safety and useful life of the equipment 2 Transport and Storage 2.1 Transport The VAG ROTOP should be transported in such a way that it is protected from external influences such as cold and damp, soiling and mechanical influences. The carrying case available from the accessories programme reliably protects the drive. 2.2 Storage The VAG ROTOP should be stored in such a way that sufficient protection against damage from improper storage is ensured. Furthermore, the VAG ROTOP should be stored in such a way that avoids condensation forming in the machine. The VAG ROTOP may not be subjected to great heat for an extended period of time. The fitting can be stored in ambient temperatures ranging from -20 C to + 50 C (protected by adequate covers). 3 Product features 3.1 Features and function description The VAG ROTOP is a portable electric drive for the easy and ergonomic operation of valves with and without housing. The hightorque drive with up to 230 Nm enables the comfortable operation of gate valves, butterfly valves and underground hydrants. The application options offered by the different coupling sleeves make the VAG ROTOP compatible with any valve. An integrated torque control prevents unintentional damage to the valves. The VAG ROTOP is available in a version with infinitely variable speed or in a version with two pre-adjusted speeds. 3.2 Fields of application The standard version of the VAG ROTOP is suitable for all valve types via the use of different coupling sleeves. For technical data concerning temperature operating limits please refer to document KAT-A Contact the manufacturer in the event of divergent operating conditions and areas of application. 3.3 Performance limits Overload protection is triggered should the VAG ROTOP become overloaded. The trigger point of overload protection depends on the period of operation and the specified torque. The overload protector is located next to the motor on the right. A safety pin integrated into the overload protector pops out and the VAG ROTOP can no longer be operated. Only after a cooling

4 off period of several minutes can the safety pin be pushed back in and operation continued. 3.4 Proper and improper mode of operation At torque of up to 100 Nm one-man operation is possible when the actuator column is used. At higher torques the VAG ROTOP must be operated by two people. Use on valves with handwheels is not permitted. For operation with the VAG ROTOP the handwheel must first be disassembled from the valve. The maximum operating conditions specified in the technical documentation (KAT 5551-A) may not be exceeded. Duty cycle Figure 1: Torque duty cycle dependence Torque

5 4 Set-up and operation 4.1 Visual inspection and preparation Before putting the VAG ROTOP into operation, perform a visual inspection of all working parts. While doing so, make sure to check the integrity of the power cable including protective switch. Damaged power cables from both the VAG ROTOP and the supplied DI protective switches can pose a hazard to the user. (6) Digital counter (forward-backward) Inlet for power cable (4) Direction of rotation switch Protector (8) LED The machine is connected to mains power The electrical connection in accordance with prevailing regulations. In addition, DI, Fi or RCD protective switches can be used. Only change the direction of rotation when shut down. Watch the counter when approaching metallic end stops. Indicator plate, rear side (2) On/off switch (3) Torque control via step switch- adjustable in 4 steps (7) Counter reset button Rotations of standard valves on the front-rear side DN Rot/stroke 11 13, , Tolerance +/- 2 rotations/stroke (5) Temperature protection switch Name plate (1) On/off switch with speed control Figure 2: Detailed view of the VAG ROTOP

6 4.2 Set-up and operation Connect the supplied DI protective switch to the ROTOP connection cable. Connect the plug to the power source (generator or mains). Push in the function button in the middle of the DI protective switch until it locks into place (hold for up to 2 seconds). Any generators or cable reels used must be suitable for operation outdoors and comply with VDE regulations. The possible power output of the generator must be at least 2000 watts in order to guarantee the required current of 230V when under load. The generator must be earthed (an earthing device must be in the generator s scope of supply). The ROTOP and the protective switch are now ready for operation. The green power indicator (item 8) goes on. If the power circuit is interrupted or an operating failure occurs the protective switch pops out and must be locked back into position for continued operation. The DI protective switch is for personal protection and must be used in accordance with VDE regulations. 4.5 Important note about torque shut-off! After being switched on the motor starts up in soft start. In this brief time (approx. two seconds) the machine starts up to maximum torque. This phase can also be used as a breakaway function. Only afterwards is the value set for automatic torque shut-off activated. If the valve is already in end position and it should be turned closed even more, only switch on the machine for a brief moment. 4.6 Adjusting the direction of rotation The direction of rotation can be both clockwise and anti-clockwise. A change in the direction of rotation is done by using the switch (item 4). Caution: Only change the direction of rotation when shut down. 4.3 Adjusting the speed In order to operate the VAG ROTOP both switches (items 1 and 2) must be pushed simultaneously. After the VAG ROTOP starts up in soft start the speed can be varied, depending on the amount of pressure applied, between 10 rpm and 70 rpm on the right handle (item 1) of the VAG RO- TOP. Even mains fluctuations which may cause the speed to change can be compensated by the operator. Speed should be lowered in the end positions in particular, in order to gently move to the seat and thus avoid impacts. 4.4 Adjusting the torque The maximum torque required can be adjusted in 4 steps by means of a step switch (item 3). Step 1: 50 Nm Step 2: 70 Nm Step 3: 150 Nm Step 4: 230 Nm -> maximum torque Please note! Only adjust the torque and direction of rotation switch when shut down. To prolong the service life of the valve and the drive, always operate at the lowest possible torque. For valves with metallic limit stops (e.g. butterfly valves) overloads to valves and the drive should be avoided by moving to end position not dependent on the torque, but the path, by watching the counter. Pay attention to the overrun of the drive. 4.7 The counter The counter (item 6) displays the number of revolutions digitally. When rotating clockwise counting goes from 0 upwards (0, 1, 2, 3,...). When rotating anti-clockwise counting goes backwards from the current counter reading (3, 2, 1, 0, -1, -2, -3, ). The reset button (item 7) can be used to reset the counter to Starting the VAG ROTOP The VAG ROTOP is started by simultaneously pushing the on/ off switch on the left handle (item 2) along with the switch of the speed control on the right handle (item 1). The integrated soft start causes a delay of approx. two seconds until full operating speed is attained, even when the speed control is pushed in all the way. 4.9 Operation One man operation without any other equipment is possible up to approx. 100 Nm. If an actuator column permanently affixed to the device is used higher loads are also possible during one man operation. For higher loads two people should operate the machine. Make sure that the VAG ROTOP is not overloaded. Refer to the diagram for duty cycle. In two man operation the duty cycle falls off sharply and falls to approx. 1 minute at 230 Nm. Failure to observe these instructions will trigger the overload protector (item 5) integrated in the ROTOP. It is located next to the motor on the right. A safety pin integrated into the overload protector pops out and the VAG ROTOP can no longer be operated. Only after a cooling off period of several minutes can the safety pin be pushed back in and operation continued.

7 5 Maintenance and repair 5.1 General safety instructions Prior to the performance of inspection and maintenance work on the valve or its assemblies, shut-off the pressurised pipeline, depressurise it and secure it against inadvertent activation. Depending on the kind and dangerousness of the fluid conveyed, comply with all required safety regulations. After completing maintenance work and before resuming operation, check all connections for proper fastening and tightness. Perform the steps described for initial set-up as described under Section 5 Set-up and operation. Statutory and local provisions as well as the safety and accident prevention regulations must be observed and complied with at all times. Any damage that may be caused by electric current and current flow must be prevented. Couplings and connections must never be disassembled when they are under pressure or current-bearing. Servicing, maintenance and inspection work as well as the replacement of spare parts must only be done qualified staff. The plant operator is responsible for determining the suitability of the staff or for ensuring the relevant qualifications. In case the operator s employees do not have the qualifications required, they need to attend a training course. This training course can e.g. be held by VAG Service employees. In addition to this, the plant operator needs to ensure that all employees have understood these Operation and Maintenance Instructions as well as all further instructions referred to in them. Protective equipment such as safety boots, safety helmets, safety clothing, goggles, protective gloves, etc. must be worn during all work requiring such protective equipment or for which such protective equipment is prescribed. Improper or wrong use of the valve should be avoided. Prior to the performance of any work on the valve and equipment it must be ensured that the relevant pipeline section has been depressurised and/or de-energised. 5.2 Inspection and operation intervals Prior to each use of the VAG ROTOP we recommend checking whether the power cable, plug and operating controls meet regulations. Half-yearly: If the VAG ROTOP is used only rarely, a test run must be carried out approximately every 6 months. Failure to do so may result in the loss of warranty. Check cables and plug for any defects prior to the test run. Yearly: Check that are retaining bolts are secure and tighten if necessary. According to statutory regulations (Accident Prevention Regulations, VGB 4m 5) all portable machines, in particular those being used outdoors, must be inspected at least once per year by the manufacturer or by an authorised qualified person. Failure to do so may result in the loss of warranty. 6 Trouble-shooting For all repair and maintenance work, please observe the general safety instructions described in Section How to contact us Headquarters VAG GmbH Carl-Reuther-Str Mannheim Germany Telephone: +49 (621) Fax: +49 (621) info@vag-group.com Service Our service hotline can be reached 24/7 world-wide. In case of emergency, please contact us by phone. Service hotline: Service by service@vag-group.com The VAG ROTOP requires only minimal maintenance. The gear housing is filled with lubricant at the factory. No topping off is necessary. Problem Possible causes Solutions Power supply not connected Connect to power VAG ROTOP won t start up Generator doesn t work Cable defective Protection switches not switched on Overload protector triggered Ensure proper working order of the generator Have cable repaired professionally Switch on DI protection switches Switch overload protector back on after a cooling off period Counter skips Unsuitable generator Replace or repair generator Power indicator LED won t go on LED defective Exchange indicator light at the factory

8 Edition 1-01/2018

VAG CEREX M300 Butterfly Valve

VAG CEREX M300 Butterfly Valve Operation and Maintenance Instructions VAG CEREX M300 Butterfly Valve KAT 1310-B Edition4 12-17 Table of Contents 1 General 3 1.1 Safety 3 1.2 Proper use 3 1.3 Identification 3 VAG reserves the right to

More information

Operating and maintenance instructions VAG RETO-STOP Non-Return Valve

Operating and maintenance instructions VAG RETO-STOP Non-Return Valve Operating and maintenance instructions VAG RETO-STOP Non-Return Valve KAT 1544-B Edition2 02-09 Content 1.General 1.1 Safety 1.2 Proper use 2.Transport and storage 2.1 Transport 2.2 Storage, packaging

More information

VAG CEREX 300 Butterfly Valve

VAG CEREX 300 Butterfly Valve Operation and Maintenance Instructions VAG CEREX 300 Butterfly Valve VAG CEREX 300-W Butterfly Valve VAG CEREX 300-L Butterfly Valve Edition 7-13-12-2017 Table of Contents 1 General 3 1.1 Safety 3 1.2

More information

Operating and Maintenance Instructions. VAG LIMU-STOP Non-Return Valve

Operating and Maintenance Instructions. VAG LIMU-STOP Non-Return Valve Operating and Maintenance Instructions VAG LIMU-STOP Non-Return Valve KAT-B 1547 Edition 1-01/2018 Table of contents 1 General 3 1.1 Safety 3 1.2 Proper use 3 1.3 Identification 3 VAG reserves the right

More information

Installation and Operating Instructions. VAG AW Non-Return Valve

Installation and Operating Instructions. VAG AW Non-Return Valve Installation and Operating Instructions VAG AW Non-Return Valve KAT-B 2450 - Edition1-03-01-2018 Table of contents 1 General 3 1.1 Safety 3 1.2 Proper use 3 2 Transport and storage 3 2.1 Transport 3 2.2

More information

VAG EKN Butterfly Valve

VAG EKN Butterfly Valve Operation and Maintenance Instructions VAG EKN Butterfly Valve KAT 1310-B Edition4 05-13 Table of Contents 1 General 3 1.1 Safety 3 1.2 Proper use 3 1.3 Identification 3 VAG reserves the right to make

More information

Operating and maintenance instructions. VAG SKR Slanted Seat Tilting Disk Check Valve

Operating and maintenance instructions. VAG SKR Slanted Seat Tilting Disk Check Valve Operating and maintenance instructions VAG SKR Slanted Seat Tilting Disk Check Valve KAT-B 1510 Edition 4-12/2010 Content 1 General 3 1.1 Safety 3 1.2 Proper use 3 2 Transportation and storage 3 2.1 Transportation

More information

VAG HYsec (F / E) Hydraulic Brake and Lift Unit

VAG HYsec (F / E) Hydraulic Brake and Lift Unit Installation and Operation Instructions VAG HYsec (F / E) Hydraulic Brake and Lift Unit VAG HYsec with external oil supply (F) VAG HYsec with internal oil supply (E) KAT-B 5512 Edition04-13-05-2015 Table

More information

VAG RIKO Plunger Valve

VAG RIKO Plunger Valve Operating and maintenance instructions VAG RIKO Plunger Valve KAT-B 2010 Edition 7-1 / 03-11 Content 1 General 3 1.1 Safety 3 1.2 Proper use 3 1.3 Marking 3 We reserve the right to make technical changes

More information

VAG KSSplus Hollow-Jet Discharge Valve

VAG KSSplus Hollow-Jet Discharge Valve Operation and Maintenance Instructions VAG KSSplus Hollow-Jet Discharge Valve KAT-B 2021-B1 Edition 1.2 2015-06-05 Contents 1 General 1 1.1 Safety 1 1.2 Proper use 1 1.3 Identification 1 VAG reserves the

More information

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) User Guide Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) version 04/2013 Content General Information 3 Warning 3 Scope of Supply 3 Overview 3 General safety details 4 Intended use 4

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS 100% recy-cling paper Bleached without chlorine GB Imprint These operating instructions are published by Conrad Electronic GmbH, Klaus- Conrad-Str 1, 92240 Hirschau/Germany No reproduction (including translation)

More information

Technical Manual Electrical Power Supply System T4002

Technical Manual Electrical Power Supply System T4002 Technical Manual Electrical Power Supply System T400 MOZELT GmbH & Co. KG Please observe the following safety information and recommendations before start-up! Copyright: MOZELT GmbH & Co. KG, D-4769 Duisburg

More information

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3 EN Operating manual Motorised zone valve Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3 This manual ensures safe and efficient use of the 3PV2 or 3PV8 force-actuated three-way valve with spring-loaded return

More information

Assembly and Maintenance Manual Type ASNU

Assembly and Maintenance Manual Type ASNU Assembly and Maintenance Manual Type ASNU Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_ASNU.docx

More information

Operating instructions Rotary actuators M135 M140 M150 M180. June 2012 / / EN

Operating instructions Rotary actuators M135 M140 M150 M180. June 2012 / / EN Operating instructions Rotary actuators M135 M140 M150 M180 June 2012 / 118614 / EN General information General information Proof of amendment Copyright Subject to alterations Manufacturer Version Date

More information

MANN+HUMMEL ENTARON XD. Installation and Maintenance Manual. Version 0709

MANN+HUMMEL ENTARON XD. Installation and Maintenance Manual. Version 0709 MANN+HUMMEL ENTARON XD Installation and Maintenance Manual Version 0709 Contact information This installation and maintenance manual is a component part of the scope of delivery. It must be kept in a safe

More information

Assembly and Maintenance Manual Type AS

Assembly and Maintenance Manual Type AS Assembly and Maintenance Manual Type AS Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_AS.docx

More information

Operating Instructions

Operating Instructions Operating Instructions BE2700 Brinkmann Immersions pumps of the series TA/STA/TAL/SAL901... 1303 Contents 1 General...1 2 Safety...2 3 Transport and storage...2 4 Description of product and accessories...2

More information

Differential Pressure Control Valve

Differential Pressure Control Valve Differential Pressure Control Valve www.ballorex.com 2 Table of contents Chapter Ballorex Delta DHC DN 15-150 1. Safety instructions 4 1.1 Rules/regulations 4 1.2 Intended use 5 1.3 Initial operation 5

More information

Operating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV Page 2. Danfoss VI.IX.A1.02 1

Operating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV   Page 2. Danfoss VI.IX.A1.02 1 Operating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV www.danfoss.com Page 2 Danfoss 2016.06 VI.IX.A1.02 1 Table of Contents: 1. OVERVIEW... 3 2. GENERAL... 3 2.1 Safety...3 2.2 Proper use...4

More information

Type 3320, Service Manual. Serviceanleitung Service Manuel

Type 3320, Service Manual. Serviceanleitung Service Manuel Electromotive 2/2-way valve Elektromotorisches 2/2-Wege-Ventil Vanne électromotorisée à 2/2 voies Service Manual Serviceanleitung Service Manuel We reserve the right to make technical changes without notice.

More information

Assembly and Operating Instructions

Assembly and Operating Instructions A35AE FU...A150AE FU en Assembly and Operating Instructions Plug-in drives Important information for: Fitters / Electricians / Users Please forward accordingly! These instructions must be kept safe for

More information

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Version with handwheel Mounting and Operating Instructions EB 8039 EN Edition May 2016 Definition of signal

More information

Documentation. RM-BV4 Micro DP. Filter control

Documentation. RM-BV4 Micro DP. Filter control Documentation RM-BV4 Micro DP Filter control Contents 1 Safety instructions... 3 2 Device description... 3 3 Installation... 4 4 Installation... 5 4.1 Connection of the differential pressure measuring

More information

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be fully read and understood 2 SAFETY Please also read through these notes carefully. 2.1 General potential danger due to: a. Failure to observe the instructions

More information

These installation and maintenance instructions must be read in full and completely understood before the installation!

These installation and maintenance instructions must be read in full and completely understood before the installation! These installation and maintenance instructions must be read in full and completely understood before the installation! 1. General information on the installation and maintenance instructions These instructions

More information

VEM motors Thurm GmbH

VEM motors Thurm GmbH VEM motors Thurm GmbH Installation, Operating and Maintenance Instructions Single-Phase Squirrel-Cage Induction Motors, Standard Version March 2005 1. General To avoid damage to the motors and equipment

More information

Wilo-Control SC-Fire Jockey

Wilo-Control SC-Fire Jockey Pioneering for You Wilo-Control SC-Fire Jockey de en fr Einbau- und Betriebsanleitung Installation and operating instructions Notice de montage et de mise en service nl Inbouw- en bedieningsvoorschriften

More information

GATE VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1

GATE VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1 Serial No. H-V011-E-12 GATE VALVES Type P (Standard: Plug) Type S (Soft Seal) Contents (1) Be sure to read the following warranty clauses of our product 1 User s Manual (2) General operating instructions

More information

Type 6213 EV, 6281 EV

Type 6213 EV, 6281 EV Type 6213 EV, 6281 EV 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions

More information

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS EmerGen Switch Manual Transfer Switch OWNER S MANUAL AND INSTALLATION INSTRUCTIONS For A Series Models 6-5001, 6-7501, 10-7501, 10-12K1 PLEASE READ THIS MANUAL IN ITS ENTIRETY BEFORE INSTALLING AND/OR

More information

Assembly Instructions

Assembly Instructions Drive Technology \ Drive Automation \ System Integration \ Services *2450452_0617* Assembly Instructions Didactics - Gear Unit Technology Helical Gear Unit R57F AD2 Edition 06/2017 2450452/EN SEW-EURODRIVE

More information

DeltaSol AX. RESOL DeltaSol AX * * Mounting Connection Operation Application examples. manual

DeltaSol AX. RESOL DeltaSol AX * * Mounting Connection Operation Application examples. manual RESOL DeltaSol AX Mounting Connection Operation Application examples DeltaSol AX *48000250* 48000250 Thank you for buying a RESOL product. Please read this manual carefully in order to put this controller

More information

GL Ludemann Y-Strainers

GL Ludemann Y-Strainers GL Ludemann Y-Strainers Installation, Operation and Maintenance Manual English Issue 1-03/2014 - Page 1/7 GENERAL These instructions are for installing, operation and maintenance of Y-strainers fabricated

More information

Assembly and Maintenance Manual Type RSBW

Assembly and Maintenance Manual Type RSBW Assembly and Maintenance Manual Type RSBW Hatschekstr. 36 69126 Heidelberg Germany Tel +49(0)6221 30470 Tel +49(0)6221 304731 info@stieber.de www.stieber.de Stieber Clutch Date of issue: 16/03/2017 GB

More information

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves Installation, Operation, Maintenance Instructions Standard Valves Series 035 000 Globe Valves Series 031 000 Angle Valves Series 033 000 3-Way-Valves 1 GENERAL INFORMATION These instructions are designed

More information

Operating Instructions for Elevator Buffers type LP

Operating Instructions for Elevator Buffers type LP Operating Instructions for Elevator Buffers type LP 1 Scope of application The Elevator Buffer type LP is an energy dissipation type buffer according to EN 81-1/2, EN 81-20, EN 81-50 5.5 and therefore

More information

Operating Instructions

Operating Instructions Operating Instructions COMBIPHON SEWERIN Wir sichern Lebensqualität. GB 103411 Measurable success by Sewerin equipment You settled on a precision instrument. A good choice! Our equipment stands out for

More information

Analytical Diaphragm Pump Series MP MP06, MP12

Analytical Diaphragm Pump Series MP MP06, MP12 Analytical Diaphragm Pump Series MP MP06, MP12 Instruction Manual Version 1.00.01 Dear customer, we have made up this operating manual in such a way that all necessary information about the product can

More information

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800 Original instructions Operating Instructions for May 2010 Electric Internal Vibrators BA No. 1092E Series NCX and NCZ These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ

More information

WR 16SE. de fr it nl es pt sv da no fi el pl hu cs tr ro sl sk bg sr hr uk ru. Handling instructions

WR 16SE. de fr it nl es pt sv da no fi el pl hu cs tr ro sl sk bg sr hr uk ru. Handling instructions en WR 16SE de fr it nl es pt sv da no fi el pl hu cs tr ro sl sk bg sr hr uk ru Handling instructions GENERAL POWER TOOL SAFETY WARNINGS WARNING Read all safety warnings and all instructions. Failure to

More information

Installation Guide perma STAR VARIO

Installation Guide perma STAR VARIO Installation Guide perma STAR VARIO The Expert in Lubrication Solutions Basic Guidelines 3 1. Blattformat: DIN A1 Maßstab: 1:1 Blattformat: DIN A3 Maßstab: 1:1 2. Mounting types 4-6 Direct mounting Remote

More information

Danfoss Butterfly Valve

Danfoss Butterfly Valve Triple Eccentric Danfoss Butterfly Valve Operating, installation and maintenance instructions Edition 1 / January 2015. Table of Contents: 1 Overview... - 1-2 General... - 1-2.1 Safety notes... - 1-2.2

More information

Storage, operating and maintenance instructions for AZ plug valves and Standard valves

Storage, operating and maintenance instructions for AZ plug valves and Standard valves ARMATUREN Plug - Valves metallic with PTFE Sleeve 2-7 way Storage, operating and maintenance instructions for AZ plug valves and Standard valves Plug - Valves FEP/PFA - lined, 2-3 way Butterfly - Valves

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual HQ 005. ELECTRIC ACTUATORS QUARTER-TURN ELECTRIC ACTUATORS Installation, Operation and Maintenance Manual s Version Ver. 1 Revision Rev. 1 Document No. HKQI-611 Small & Compact Design High corrosion resistance

More information

original operating manual Operating manual Translation of the Item-No.: ,

original operating manual Operating manual Translation of the Item-No.: , Translation of the original operating manual Operating manual Item-No.: 015 431 551, 015 431 581 Important! Copyright The operating manual is always to be read before commissioning the equipment. No warranty

More information

Installation Instructions

Installation Instructions Installation Instructions ELEKTROMAT SE 15.48-25,40 NOT DEFINED Model: 10004112 10006 -en- Status: 21.07.2016 2 GfA ELEKTROMATEN UK Ltd Titan Business Centre Spartan Close Warwick CV34 6RR United Kingdom

More information

Rotary feed-through DDF-S/-KS

Rotary feed-through DDF-S/-KS Translation of the Original Operating Manual Rotary feed-through DDF-S/-KS Assembly and Operating Manual Superior Clamping and Gripping Imprint Imprint Copyright: This manual remains the copyrighted property

More information

Instruction Manual. Automatic Fuel Oil De-aerator Flow-Control. Flow-Control 3/K-1 # Flow-Control 3/K-2 # 70019

Instruction Manual. Automatic Fuel Oil De-aerator Flow-Control. Flow-Control 3/K-1 # Flow-Control 3/K-2 # 70019 Mess-, Regel- und Überwachungsgeräte für Haustechnik, Industrie und Umweltschutz Lindenstraße 20 DE-74363 Güglingen Telefon: +49(0)7135-102-0 Service: +49(0)7135-102-211 Telefax: +49(0)7135-102-147 E-Mail:

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation Globe control valve, pneumatically operated Actuator sizes 40 mm - 125 mm, Nominal diameter DN10-65 Kolbengesteuertes Geradsitzventil Antriebsgrößen 40 mm - 125 mm, Nennweiten DN10-65 Vanne à siège droit

More information

Installation manual portable distributors

Installation manual portable distributors EN Installation manual portable distributors EN 60003206 Issue 11.2016 15/11/2016 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2 Intended

More information

Installation, Operating & Maintenance Instructions. All-metal gate valve with compact or extended pneumatic actuator

Installation, Operating & Maintenance Instructions. All-metal gate valve with compact or extended pneumatic actuator Installation, Operating & Maintenance Instructions All-metal gate valve with compact or extended pneumatic actuator Series 48 DN 16 320 mm (I.D. ⅝" 12") This manual is valid for the following product ordering

More information

Starting up hydraulic systems

Starting up hydraulic systems General / Installation A hydraulic system that operates economically, safely, and trouble-free requires careful planning, as well as proper installation and start-up. Conscientious maintenance has a considerable

More information

Assembly and maintenance manual Type FSO, FSO-GR, FS, HPI

Assembly and maintenance manual Type FSO, FSO-GR, FS, HPI Type FSO, FSO-GR, FS, HPI Hatschekstr.36 69126 Heidelberg Deutschland Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 23.08.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\M1124E_0_FSO_FSO-GR_FS_HPI.docx

More information

HST -LS Interlocking device (Translation of Original Manual)

HST -LS Interlocking device (Translation of Original Manual) Installation and Operating Manual for Components HST -LS Interlocking device (Translation of Original Manual) HST-LS Ident.-No.: 10268 HST-LS Ident.-No.: 10269 HST-LS, pictured Ident-Nr. 10269 The image

More information

Element C8.3 Installation, Use and Inspection of Electrical Systems

Element C8.3 Installation, Use and Inspection of Electrical Systems .3 Installation, Use and Inspection of Electrical Systems Duty Holders Electricity at Work Regs 1989 EWR Employers and Self Employed Comply with regs as far as they are under their control Managers of

More information

Installation manual wall-mounted distributor

Installation manual wall-mounted distributor EN Installation manual wall-mounted distributor EN 60003233 Issue 11.2016 2016-14-11 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2

More information

HV angle valve with single acting pneumatic actuator and closing spring (NC)

HV angle valve with single acting pneumatic actuator and closing spring (NC) Installation, Operating & Maintenance Instructions HV angle valve with single acting pneumatic actuator and closing spring (NC) Series 264 DN 100 160 mm (I. D. 4 6 ) This manual is valid for the following

More information

8.50 Kampmann Equestrian Solarium Perfect Enhances the Vital Functions and the Immune System Table of Contents.

8.50 Kampmann Equestrian Solarium Perfect Enhances the Vital Functions and the Immune System Table of Contents. 1.26 1.45 8.50 Kampmann Equestrian Solarium Perfect Table of Contents Table of Contents 1.26 1.46 1. Correct and Proper Use.......................................... 3 1.1 Personal Qualification 1.2 Limits

More information

Ball valve for pipeline systems

Ball valve for pipeline systems Ball valve for pipeline systems in brass, nickel-plated Installation Instructions 90244210T94Z003K000 V1.00/EN/00674685 Contents Contents 1 Safety information...............................................

More information

Installation and operating instructions. BPW Landing gear. BPW-BA-SV e

Installation and operating instructions. BPW Landing gear. BPW-BA-SV e Installation and operating instructions BPW Landing gear BPW-BA-SV 37451601e Page 2 BPW-BA-SV 37451601e BPW-BA-SV 37451601e Page 3 Contents: Intended use 2 1. General safety notes... Page 2 2. Intended

More information

60 Watt Industrial LED Low Bay Light

60 Watt Industrial LED Low Bay Light 60 Watt Industrial LED Low Bay Light Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Type 5404 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating instructions...2 2 Intended use...3 3

More information

Quick-Disconnect Coupling one-hand operation Push Pull ND 5, connecting thread G 1/4,max. operating pressure 500 bar

Quick-Disconnect Coupling one-hand operation Push Pull ND 5, connecting thread G 1/4,max. operating pressure 500 bar Issue 12-2013 Quick-Disconnect Coupling one-hand operation Push Pull ND 5, connecting thread G 1/4,max. operating pressure 500 bar Figure 1: Coupling complete Figure 4: Coded coupling, complete Table of

More information

Instruction Manual. Sewage lifting station compli 300

Instruction Manual. Sewage lifting station compli 300 Instruction Manual Sewage lifting station compli 300 Safety instructions Areas of application Electrical connection Installation Servicing Technical data Appendix JUNG PUMPEN GmbH Industriestr. 4-6 33803

More information

Instruction manual and installation guide Traction sheave brake TSB TSB

Instruction manual and installation guide Traction sheave brake TSB TSB Instruction manual and installation guide Traction sheave brake TSB 2000-1 TSB 2000-2 Content Traction sheave brake Page 1. Safety 2 1.1 Explanation of symbols 2 1.2. General safety instructions 3 2. Product

More information

Installation, Operating & Maintenance Instructions. HV gate valve with pneumatic actuator. Series 110 DN mm (I. D.

Installation, Operating & Maintenance Instructions. HV gate valve with pneumatic actuator. Series 110 DN mm (I. D. Installation, Operating & Maintenance Instructions HV gate valve with pneumatic actuator Series 110 DN 250 320 mm (I. D. 10" 12") This manual is valid for the following product ordering numbers: 11048-.

More information

OPERATIONS MANUAL CR Thermoreactor

OPERATIONS MANUAL CR Thermoreactor OPERATIONS MANUAL CR 2200 Thermoreactor CR 2200 Note For the most recent version of the manual, please visit www.ysi.com. Contact Copyright YSI 1725 Brannum Lane Yellow Springs, OH 45387 USA Tel: +1 937-767-7241

More information

USER AND SAFETY MANUAL

USER AND SAFETY MANUAL USER AND SAFETY MANUAL HANDLE- BARS STEM COLLAR ROD SADDLE SAFETY HOOK- STRIP BRAKE SUPPORT BARS AFT TUBE FRONT TUBE SAFETY RULES SECURE THE ROD AND ATTACH SAFETY HOOK-STRIP before every ride. RIDE WHEELA

More information

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions Drive Unit e-drive1 Installation instructions 04/2014 English translation of the original German installation instructions Contents Foreword... 3 Availability... 3 Structural features in the text... 3

More information

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

USER S MANUAL FOR F & Q. Submersible Sewage Pumps USER S MANUAL FOR F & Q Submersible Sewage Pumps 50WQ Series The F&Q pumps are carefully inspected and tested to ensure operating performance and safety. However, failure to follow the instructions and

More information

Solenoid Operator 0516 / 1216

Solenoid Operator 0516 / 1216 nass magnet GmbH Edition no. 2 Eckenerstraße 4-6 2007-01-10 D-30179 Hannover Rev.2 070110 Solenoid Operator 0516 / 1216 Operating Instructions NN 8220 126 and EC Declaration of Conformity Dear Customer!

More information

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve Type 3310/AT and Type 3310/3278 Pneumatic Control Valves Type 3310 Segmented Ball Valve Fig. 1 Type 3310/3278 with positioner Fig. 2 Type 3310/AT Mounting and Operating Instructions EB 8222 EN Edition

More information

Installation and Operating Instructions Magnetic Vibrator MR 1

Installation and Operating Instructions Magnetic Vibrator MR 1 Installation and Operating Instructions Magnetic Vibrator MR 1 (Translation of the Original Instruction Manual) Würges Vibrationstechnik GmbH Daimlerstraße 9 D-86356 Neusäß Telephone +49 821 999824-00

More information

WR 22SE WR 25SE WR25SE. Handling instructions

WR 22SE WR 25SE WR25SE. Handling instructions WR 22SE WR 25SE WR25SE Handling instructions GENERAL POWER TOOL SAFETY WARNINGS WARNING Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric

More information

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator Type 3510 Micro-flow Valve In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator DIN version Translation of original instructions Type 3510-1 (left) and Type 3510-7 (right)

More information

110 Volt/12 Volt Portable Inflator

110 Volt/12 Volt Portable Inflator 110 Volt/12 Volt Portable Inflator Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety

More information

Operating Instructions Flexdip CYA112

Operating Instructions Flexdip CYA112 BA00432C/07/EN/13.13 71207066 Products Solutions Services Operating Instructions Wastewater assembly About this document Safety messages The structure, signal words and safety colors of the signs comply

More information

Timing-Belt Reverse Unit 8 80 R25 Notes on Use and Installation

Timing-Belt Reverse Unit 8 80 R25 Notes on Use and Installation Timing-Belt Reverse Unit 8 80 R25 Notes on Use and Installation Content General General hazard warning 2 Appropriate use 3 Content Application 3 Technical Data/Scope of Supply 3 Application Options 4 Fitting

More information

Technical details. Product features

Technical details. Product features VAG Hydrants VAG NOVA 284 Standpost Hydrant Maintenance-free stem seal Nominal diameter DN 80 / DN 100 Installation depth DN 80: 1.00 m / 1.25 m / 1.50 m DN 100: 1.25 m / 1.20 m Standard model: Upper and

More information

Butterfly Valve Type 58 (PDCPD)

Butterfly Valve Type 58 (PDCPD) Serial No. H-V074-E Butterfly Valve Type 58 (PDCPD) 700mm (28 ) User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General

More information

CM3-E Operation Manual DOK-347E / Rev.:1.01 KH / October 1999 Portable 3 turbine check meter

CM3-E Operation Manual DOK-347E / Rev.:1.01 KH / October 1999 Portable 3 turbine check meter -E DOK-347E / Rev.:1.01 KH / October 1999 Portable 3 turbine check meter Contents 1 General Remarks... 1-1 1.1 About This Manual... 1-1 1.2 How to Use This Manual... 1-1 2 Approval... 2-1 2.1 Explosion

More information

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type Electropneumatic Converters i/p Converter Type 3913-0001 Fig. 1 Type 3913-0001 Electropneumatic Converter with pressure gauge and bracket Mounting and Operating Instructions EB 3913 EN Edition August 2011

More information

Installation, Operating & Maintenance Instructions. HV angle valve with pneumatic actuator single acting with closing spring (NC)

Installation, Operating & Maintenance Instructions. HV angle valve with pneumatic actuator single acting with closing spring (NC) Installation, Operating & Maintenance Instructions HV angle valve with pneumatic actuator single acting with closing spring (NC) Series 264 DN 10 50 mm (I. D. ⅜" 2") HV inline valve with pneumatic actuator

More information

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

USER S MANUAL FOR F & Q. Submersible Sewage Pumps USER S MANUAL FOR F & Q Submersible Sewage Pumps 100WQ Series The F&Q pumps are carefully inspected and tested to ensure operating performance and safety. However, failure to follow the instructions and

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions contain

More information

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator Type 3510 Micro-flow Valve In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator ANSI version Translation of original instructions Type 3510-1 (left) and Type 3510-7

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating Instructions... 2 2 Authorized use...

More information

RADEX -N Composite Operating/Assembly instructions

RADEX -N Composite Operating/Assembly instructions 1 of 14 RADEX -N is a torsionally stiff flexible steel lamina coupling. It is able to compensate for shaft misalignment, for example caused by thermal expansion, etc. note ISO 101. Drawn: 0.05.15 Kb/Wig

More information

Operating Instructions K Always on the safe side.

Operating Instructions K Always on the safe side. Operating Instructions K9 4953. Always on the safe side. KaVo Dental GmbH Wangener Straße 78 D-88299 Leutkirch Tel.: 0 75 61 / 86-150 Fax: 0 75 61 / 86-265 A 1 User information...2 A 1.1 Meaning of the

More information

Users Manual. Phase Rotation Indicator

Users Manual. Phase Rotation Indicator 9040 Phase Rotation Indicator Users Manual PN 2438546 April 2005, Rev.2, 5/11 2005-2011 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are

More information

Mini UHV gate valve with manual actuator with pneumatic actuator

Mini UHV gate valve with manual actuator with pneumatic actuator Mini UHV gate valve with manual actuator with pneumatic actuator This manual is valid for the valve ordering numbers: 004/8/3/34-. E0/08 004/8/3/34-. E//3/4 004/8/3/34-. E//3/4 004/8/3/34-. E4/4/34/44

More information

Installation, Operating & Maintenance Instructions. Series 081, DN (I.D. 2½" - 4") Hot surfaces; do not touch!

Installation, Operating & Maintenance Instructions. Series 081, DN (I.D. 2½ - 4) Hot surfaces; do not touch! Vacuum Gate Valve This manual is valid for the valve ordering number(s): 08136-FA14/24/34/44 08138-FA14/24/34/44 08140-FA14/24/34/44 The fabrication number is indicated on each product as per the label

More information

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN Electropneumatic Converters i/p Converters Type 6111 Fig. 1 Type 6111 in standard version Fig. Type 6111 mounted on a supply air manifold Fig. 3 Type 6111 in field enclosure Mounting and Operating Instructions

More information

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP Model 54011-0 OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP Questions, problems, missing parts? Before returning to the store call AQUAPRO Customer Service 8 a.m. - 5 p.m., EST, Monday-Friday 1-844-242-2475

More information

ELECTRIC ENGRAVER 15W WARRANTY INSTRUCTION MANUAL SPECIFICATIONS WHAT S IN THE BOX. ozito.com.au. Electric Engraver

ELECTRIC ENGRAVER 15W WARRANTY INSTRUCTION MANUAL SPECIFICATIONS WHAT S IN THE BOX. ozito.com.au. Electric Engraver IN ORDER TO MAKE A CLAIM UNDER THIS WARRANTY YOU MUST RETURN THE PRODUCT TO YOUR NEAREST BUNNINGS WAREHOUSE WITH YOUR BUNNINGS REGISTER RECEIPT. PRIOR TO RETURNING YOUR PRODUCT FOR WARRANTY PLEASE TELEPHONE

More information

MODEL HD99 HYDRAULIC ONE MAN TOWABLE EARTHDRILL

MODEL HD99 HYDRAULIC ONE MAN TOWABLE EARTHDRILL DO NOT THROW AWAY IMPORTANT MANUAL MODEL HD99 HYDRAULIC ONE MAN TOWABLE EARTHDRILL Operators Manual GROUND HOG, INC. P.O.BOX 290 San Bernardino, CA. 92402 Phone (909) 478-5700 Fax (909) 478-5710 E-mail:

More information

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Type range: UN813.3ANI UN813.4ANI UN813.3ANDCB UN813.4ANDCB UN813.5ANI Fig. 1: UN813.3ANI Fig. 2: UN813.4ANI You have selected

More information

RESOL SBS 1000 * * Connection Operation

RESOL SBS 1000 * * Connection Operation RESOL SBS 1000 Connection Operation FlowCon SBS 1000 A www.resol.de *48003820* 48003820 Thank you for buying this RESOL product. Please read this manual carefully to get the best performance from this

More information