Model GT 1175 Electrical Installation Manual **with U30 Microprocessor Controller** (with Revision D Software)

Size: px
Start display at page:

Download "Model GT 1175 Electrical Installation Manual **with U30 Microprocessor Controller** (with Revision D Software)"

Transcription

1 A M P MADE IN JAPAN GYRO TEC 0V MOTOR P POWER B ERROR GYRO TEC To protect against risk of fire or electric shock,use only the certified power supply. Adjustments to the door can only be made with the andy Terminal. Do not disassemble the control box. There are no user serviceable parts inside. To maintain warranty,repairs must be made by authorized facilities. ANDY TERMINAL P Mode SW Usage M MODE FUNCTION [SLIDING DOOR] SYMBOL Gnd DCV Gnd OLD OPEN NIGT Interior Activation olding Beam Mode Switch (see Mode SW Usage shown left) Exterior Activation Sequential Activation OUT.A Amax.(0-0V),.Amax.(0-0V) Common Auxiliary Output (-Collector) OUT VDC-(Common) S W Gemini Drive Muskego, Wisconsin 0 Phone: () - Fax: () - Technical Support: () - Model GT Electrical Installation Manual **with U0 Microprocessor Controller** (with Revision D Software) ANDY TERMINAL ARNESS P/N - P/N - MOTOR/OPERATOR P/N - U0 CONTROL P/N -0-0 TB ZNR ZNR S NOISE FILTER T TRANSFORMER TB - DS-0 POWER P INDICATORS 0VAC 0/0z WARNING Gnd Gnd ONE WAY TWO WAY Microprocessor Controller 0- VDC+ VDC-(Common) Contact Output (Class Load only) 0V(.Vpeak)max. B M OUT.C OUT.B 0 RELATED DEVICES P 0 ACV ± 0% 0 / 0 z BLACK (OT) (COMMON) OFF POWER SWITC 0 VAC ARNESS P/N - GROUND LUG SCREW TO EADER GROUND ARNESS P/N - AUXILIARY 0 VAC POWER WIRES (TESE WIRES NORMALLY COILED AND TIED UP) VDC+ VDC-(COMMON) FUNCTION [SLIDING DOOR] INTERIOR ACTIVATION OLDING BEAM UCED OPENING SWITC Mode Switch (see Mode SW Usage shown left) Exterior Activation Sequential Activation Contact Output (Class Load only) 0V(.Vpeak)max. Amax.(0-0V),.Amax.(0-0V) Common Auxiliary Output (-Collector) VDC-COMMON LABEL ON U0 CONTROL SYMBOL DCV B M 0 OUT.A OUT.B OUT.C OUT RELATED DEVICES - P 0 (OUT A) VIOLET TERMINAL ON U0 MAIN ARNESS WIRING FOR ELECTRIC LOCK ONLY SOWN P/N - BLK WT GRY VIO FAIL SECURE FAIL SECURE LOCK ASSY. P.N U0 ELECTRIC STRIKE OUTPUT SIGNAL ANDY TERMINAL: AUX OUTPUT = 0, OUTPUT TIMER =, ROCKER SWITC SETTING: ONE WAY OR NIGT MODE ON OUTPUT: 0 = ELECTRIC STRIKE OUTPUT OFF ACTIVATION SIGNAL OUTPUT TIMER 0 =(DO NOT USE) =(DO NOT USE) =(DO NOT USE) = ELECTRIC STRIKE FUNCTION OFF OUTPUT SIGNAL ON SEC OPENING OUTPUT TIMER.0 SEC FULLY CLOSED FULL OPEN CLOSING FULLY CLOSED DN 0 WARNING Turn OFF all power to the Automatic Door if a Safety System is not working. Instruct the Owner to keep all power turned OFF until corrective action can be achieved by a trained technician. Failure to follow these practices may result in serious consequences. NEVER leave a Door operating without all Safety detection systems operational. Part #-0-0 Rev. /0/

2 TIS PAGE IS INTENTIONALLY LEFT BLANK

3 Electrical Installation Manual U-0 Control Rev. -0- Part #-0-0 Table of Contents Warning Labels... iii General Safety Recommendations... iv CAPTER : SCOPE... - Section a: To the Installer...- Section b: Objective...- CAPTER : GETTING STARTED... - Section a: About the U0 Microprocessor Control...- Section b: Electrical Specifications...- Section c: Output Power Guidelines...- Section d: eader Layout...- CAPTER : CONNECT INCOMING 0 VAC WIRES... - CAPTER : IDENTIFY OPERATING WIRES Section a: Pin Controller Terminal Block Assignments Section b: Sensor Wire Connections...- Section c: Rocker Switch Settings...- CAPTER : WIRING DIAGRAMS (SURFACE APPLIED SLIDERS)... - Section a: () Acusensors and () olding Beam...- Section b: () Optex I-One and () olding Beam...- Section c: () Acusensors, () olding Beam and () Breakout Beam Control...- Section d: () Optex I-One, () olding Beam and () Breakout Beam Control...- Section e: () Wizard G, and () olding Beam...- Section f: () Wizard G, () olding Beam and () Breakout Control...- i

4 Electrical Installation Manual U-0 Control Part #-0-0 Rev. -0- CAPTER : INFRA BEAM WIRING Section a: Wiring () olding Beam...-0 Section b: Wiring () olding Beams...- Section c: Wiring olding Beam for Breakout...- CAPTER : ELECTRIC LOCK WIRING... - Section a: Adjust the Strike....- Section b: U0 with Fail Safe Electric Lock...- Section c: U0 with Fail Secure Electric Lock...- Section d: U0 with Magnetic Lock...- CAPTER : CUSTOM WIRING... - Section a: U0 Configured for Remote Control of Modes...- Section b: Sidelite Sensors...- Section c: U0 Using Card Readers or other Secure Activation Devices...- CAPTER : TROUBLESOOTING CAPTER 0: RETURN POLICY Section 0a: ow to Print and Fill out a Return Material Tag ii

5 Electrical Installation Manual U-0 Control Rev. -0- Part #-0-0 WARNING LABELS Warning labels are universal and used to alert an individual of potential harm to one s self or to others. The following warning labels are listed in a hierarchy order that defines the most potential danger first, and the least potential danger last. Please refer to this page in the event that a warning label is displayed within this manual and further definition needs to be explained. DANGER Indicates potentially dangerous situations. Danger is used when there is a hazardous situation where there is a high probability of severe injury or death. It should not be considered for property damage unless personal injury risk is present. WARNING Indicates a hazardous situation which has some probability of severe injury. It should not be considered for property damage unless personal injury risk is present. Notice: Indicates a hazardous situation which may result in a minor injury. Caution should not be used when there is a possibility of serious injury. Caution should not be considered for property damage accidents unless a personal injury risk is present. Indicates a statement of company policy as the message relates to the personal safety or protection of property. Notice should not be used when there is a hazardous situation or personal risk. Note: Indicates important information that provides further instruction. iii

6 Electrical Installation Manual U-0 Control Part #-0-0 Rev. -0- GENERAL SAFETY RECOMMENDATIONS WARNING Do not install, operate or service this product unless you have read and understand the General Safety Recommendations, Warning Labels, contained in this manual. Failure to do so may result in bodily injury, or property damage. WARNING Notice: DANGER Notice: Read, study and understand the installation and operating instructions contained in, or referenced in this manual before operating. If you do not understand the instruction, ask a qualified technician. Failure to do so may result in bodily injury, or property damage and will nullify all warranties. This manual and the owner s manual must be given to and retained by the purchasing facility or end user. Disconnect all power to the junction box prior to making any electrical connections. Failure to do so may result in seriouc personal or fatal injury. When uncertain whether power supply is disconnected, always verify using a voltmeter. Wiring must meet all local, state, federal or other governing agency codes. DANGER Notice: All electrical troublshooting or service must be performed by qualified electrical technicians and must comply with all applicable governing agency codes. Do not place finger or uninsulated tools inside the electrical controller. Touching wires or other parts inside the enclosure may cause electrical shock, serious injury or death. The Ground wire from the Magnum IV Control 0 VAC arness, and the Incoming 0 VAC Ground wire must be connected to the Ground screw located within the Swing door eader. Note: Note: If the door appears broken or does not seem to work correctly, it should be immediately removed from service until repairs can be carried out or a qualified service technician is contacted for corrective action. All Adjustments must be made with a small screwdriver. Do Not use a pencil. Do Not take shortcuts. iv

7 Electrical Installation Manual U-0 Control Rev. -0- Part #-0-0 CAPTER : SCOPE Section a: To the Installer The purpose of this manual is to familiarize the installer and purchaser with the proper installation and operation of this system. It is essential that this equipment be properly installed and operational before the door is used by the public. It is the installer s responsibility to inspect the operation of the entrance system to be sure it complies with any applicable standards. Instruct the building owners and operator on the essentials of the operation of the U0 Microprocessor Controller. The owner should follow these instructions to determine whether the door is operating properly and should immediately call for service if there is any malfunction. All installation changes and adjustments must be made by qualified, trained technicians. Section b: Objective The U0 Microprocessor Controller is designed to be installed within the eader of the GT- Slide Door systems. This manual offers step by step instructions. Scope -

8 Electrical Installation Manual U-0 Control Part #-0-0 Rev. -0- CAPTER : GETTING STARTED Section a: About the U0 Microprocessor Control The U0 Microprocessor Control is utilized on all GT- Slide Door systems to control numerous operating characteristics that include (but not limited to): speed, recycling sensitivity and reduced opening width. Note: The U0 Microprocessor Control will need to be programmed after installation is complete. The U0 Microprocessor Control is also utilized to output power to accessories and/or auxiliary equipment such as: Sensors Modules There are times when the U0 Microprocessor Control is not utilized to output power because some accessories and/or auxiliary equipment are shipped with it s own dedicated power supply. Section b: Electrical Specifications All Wiring Diagrams included within this manual, reflect typical primary and secondary circuits that are installed at the Factory. The low voltage Reed Switch ( VDC) and Sensor(s) are also installed complete with connector housings at the Factory. Note: factory utilizes Underwriters Laboratories (UL) recognized component wire, terminals and connector housings to manufacture GT- Slide Door systems. Table - Sensors Sensor Part Number Function Power Source Current Consumption Acusensor -0- Infrared to AC or DC 00mA Wizard G - Infrared + Microwave to VAC or VDC 0mA (ea.unit) at VDC Optex i-one -0 Infrared to VAC or to 0 VDC 0mA Table - Modules Module Part Number Function Power Source Current Consumption Optex Beam -0-0 Beam & Control to AC or DC 0mA CP/RX Radio Control Receiver - RF Signal Transmission to AC or DC 0mA (ea.unit) at VDC - Getting Started

9 Electrical Installation Manual U-0 Control Rev. -0- Part #-0-0 Section c: Output Power Guidelines TOTAL current draw from the U0 Microprocessor Control must not exceed 0 ma (0. amps) when outputting power to: Sensors Modules Accessories Auxiliary Equipment If TOTAL current draw exceeds 0mA (0. amps) the installer must utilize an auxiliary power supply such as a VAC Transformer (P/N -0). The U0 Microprocessor Control and/or the Power Supply Module Must Not be used to output power to Magnetic Locks or Electric Strikes. To determine if an auxiliary power supply must be used, add together each current draw for each device. Please refer to the formula shown below: Example: A GT- Slide Door is to be fitted with the following devices: x Optex i-one 0 ma = 0 ma x Optex Beam 0 ma = 0 ma Total = 0 ma 0mA exceeds 0mA. An Auxiliary Power Supply must be used to supply power to the Optex Beam Module. Section d: eader Layout Nabco GT- Sliding Door systems come in many sizes and configurations. Because of this components within the eader are layed out in ( of ) different configurations to ensure proper operation of the Drive Belt. Please see configuration details listed below: Operator/Control/Power eader Width is not wide. Operator needs to be installed to the left of the U0 Microprocessor Control. Please see Figure -. Power/Operator/Control eader Width is wide, but Operator still needs to be installed between the Power Supply and the U0 Microprocessor Control. Please see Figure -. Power/Control/Operator eader Width is wider. Operator can be installed to the right of the Power Supply and the U0 Microprocessor Control. Please see Figure -. Note: Note: The Power Supply must never be installed between the U0 Microprocessor Control and the Operator. No matter the location, electrical wiring for all () components stays the same. Getting Started -

10 TB ZNR ZNR TB S ZNR ZNR NOISE FILTER S NOISE FILTER T GYRO TEC DS-0 - MADE IN JAPAN T TB TB 0 0 GYRO TEC DS-0 - MADE IN JAPAN WARNING ANDY TERMINAL P To protect against risk of fire MOTOR P or electric shock,use only the certified power supply. Microprocessor Controller Mode SW Usage 0- POWER M MODE TWO WAY FUNCTION [SLIDING DOOR] SYMBOL GYRO TEC Gnd ONE WAY VDC+ DCV B Gnd Gnd OLD OPEN VDC-(Common) Gnd NIGT Interior Activation olding Beam B Mode Switch (see Mode SW Usage shown left) M Exterior Activation ERROR Sequential Activation with the andy Terminal. 0 Sidelite Presence Senso r Do not disassemble the control box. Contact Output (Class Load only) OUT.A There are no user serviceable parts 0V(.Vpeak)max. OUT.B inside. Amax.(0-0V),.Amax.(0-0V) Common OUT.C Auxiliary Output (-Collector) OUT To maintain warranty,repairs must be VDC-(Common) made by authorized facilities. WARNING ANDY TERMINAL P To protect against risk of fire MOTOR P or electric shock,use only the certified power supply. Microprocessor Controller Mode SW Usage 0- POWER M MODE TWO WAY FUNCTION [SLIDING DOOR] SYMBOL GYRO TEC Gnd ONE WAY VDC+ DCV B Gnd Gnd OLD OPEN VDC-(Common) Gnd NIGT Interior Activation olding Beam B Mode Switch (see Mode SW Usage shown left) M Exterior Activation ERROR Sequential Activation with the andy Terminal. 0 Do not disassem le the control ox. Contact Output (Class Load only) OUT.A There are no user servicea le parts 0V(.Vpeak)max. OUT.B inside. Amax.(0-0V),.Amax.(0-0V) Common OUT.C Auxiliary Output (-Collector) OUT To maintain warranty,repairs must e VDC-(Common) made y authori ed facilities. 0 0 GYRO TEC DS-0 - MADE IN APAN TB NR NR S NOISE FILTER A RNING ANDY TERMINAL P To protect against risk o ire MOTOR P or electric shock,use only the certi ied power supply. Microprocessor Controller Mode S Usag e 0- PO E R M MODE T O A Y FUNCTION [SLIDING DOOR] SYMBOL GYRO TEC Gnd ONE AY VDC DCV B Gnd Gnd OLD OPEN VDC-(Common) Gnd NIGT Interior Activation olding Beam B Mode Switch (see Mode S Usage shown le t) M Exterior Activation ERROR Sequential Activation with the andy Terminal. 0 Do not disassem le the control ox. Contact Output (Class Load only) OUT.A There are no user servicea le parts 0V(.Vpeak)max. OUT.B inside. Amax.(0-0V),.Amax.(0-0V ) Common OUT.C Auxiliary Output (-Collector) OUT To maintain warranty,repairs must e VDC-(Common) made y authori ed acilities. 0 0 T TB Electrical Installation Manual U-0 Control Part #-0-0 Rev. -0- eader U0 Microprocessor Controller >POM< INDICATORS POWER P 0VAC 0/0 Ad ustments to the door can only e made RELATED DEVICES P I A M P O TRANSFORMER LABEL DN 0 Operator Figure - Power Supply eader Layout OCP with or without Electric Lock eader Operator I A M P O TRANSFORMER LABEL >POM< INDICATORS PO E R P 0VAC 0/0 Ad ustments to the door can only e made RELATED DEVICES P DN 0 Power Supply U0 Microprocessor Controller Figure - eader Layout POC with or without Electric Lock eader Operator DN 0 I A M P O TRANSFORMER LABEL INDICATORS POWER P 0VAC 0/0z Adjustments to the door can only be made RELATED DEVICES P >POM Power Supply Figure - U0 Microprocessor Controller eader Layout PCO with or without Electric Lock - Getting Started

11 L N -CIRCUIT- -BREAKER- INDICATES POWER IS OFF PRESS TO RESET ASSEMBLY P/N ENTRANCES, INC. GYRO TEC MADE IN JAPAN 0 0 POWER B ERROR MOTOR P GYRO TEC To protect against risk of Fire or electric shock,use only the Mode SW Usage M MODE Adjustments to the door can only be made with the andy Terminal. Do not disassemble the control box. There are no user serviceable parts inside. To maintain warranty,repairs must be made by authorized facilities. FUNCTION (SLIDING DOOR) VDC + VDC-(Common) Interior n olding Beam Exterior A 0V(.Vpeak)max Contact Output (Class Load only) VDC-(Common) ANDY TERMINAL P SYMBOL DCV B M OUT. C OU T Electrical Installation Manual U-0 Control Rev. -0- Part #-0-0 CAPTER : CONNECT INCOMING 0 VAC WIRES DANGER Notice: Disconnect power to the junction box prior to making any electrical connections. Failure to do so may result in serious personal or fatal injury. When uncertain whether power supply is disconnected, always verify using a voltmeter. Wiring must meet all local, state, federal or other governing agency codes.. Ensure all power is disconnected at the Junction box.. Ensure all power to the GT- Slide Door is Off.. Inspect the location and grade of all Incoming 0 VAC power cables.. Insert all Incoming 0 VAC, single phase, amp (minimum) power wires into the pre drilled Electric Service Access ole located at the left or right side of Jamb Tube and eader End Cap. a. It is recommended for the Installer to house all Incoming 0 VAC wires within an Electrical Conduit. Keep all Incoming 0 VAC wiring separate from low voltage wiring within eader. Do Not route 0 VAC wires near the U0 Microprocessor Controller and Operater.. Please see Figure -, to follow steps on how to connect Incoming 0 VAC wires to Power Supply.. Go to the TB Port located on the Left side of the Power Supply Module.. Insert the Incoming 0 VAC Black (OT) wire into the Circuit marked L.. Insert the Incoming 0 VAC White (Neutral) wire into the Circuit marked N.. Insert Green (Grounding) wire into the Circuit marked PE. DANGER Read and understand the U0 Controller Setup and Programming Manual P/N -000 before attempting to power-up the GT- Slide Door. Failure to do so may result in damage to the Slide door and/or injury to the installer and will nullify all warranties. Black Wire (ot) White Wire (Common) PE TB NOISE FILTER S LOAD T TB DS-00 D-0 Nabtesco Corporation >POM< INDICATORS POWER P 0VA C 0/0z WARNING TWO WAY ONE WAY OLD OPEN NIG T Microprocessor Controller 0- Auxiliary Output (-Collector) Amax.(0-0V),.Amax.(0-0V) Common OUT. A OUT. B 0 RELATED DEVICES P Grounding Wire P/N - OFF Power Switch Figure - DN 0 Connect Incoming 0 VAC Wires to Power Supply Connect Incoming 0 VAC Wires -

12 Electrical Installation Manual U-0 Control Part #-0-0 Rev. -0- CAPTER : IDENTIFY OPERATING WIRES Section a: Note: Note: Note: Pin Controller Terminal Block Assignments All wires are identified by color. All references to signals are made in connection with Common (Red). Use a flat-blade screwdriver to remove the Terminal Connector from the U0 Microprocessor Controller. Ensure that all wires are matched to each appropriate Terminal. Each Terminal is numbered with corresponding information on the Face Plate of the U0 Microprocessor Controller. Common Terminal indicates terminal can be Output or Input. * Color/Color denotes a base wiring Color with a stripe Color. For example: Black/Red indicates a Black wire with a Red Stripe. Terminal # Symbol Color Description DCV Brown Red Black B White Green Orange M Orange/ White* Black/ Red* Yellow Output terminal Sensor power source. Output is VDC with a maximum capacity of 0mA (. amp). Common terminal Provides common ground for the VDC power and signal source. Input terminal Interior Activation signal. s the door in two-way and one-way modes only. Input terminal olding Beam signal. s or re-opens a Sliding door. Input terminal signal. Reduces Slide door opening when switched to Red (). Input terminal Mode Switch One (SW). Used to acheive special functions. Please refer to Switch Settings section within this chapter. Input terminal Mode Switch Two (SW). Used to acheive special functions. Please refer to Switch Settings section within this chapter. Input terminal Exterior Activation signal. s the door in two-way mode only. Input terminal Sequential Activation signal. Allows a sequence of signals to open and close Slide door. -0 Identify Operating Wires

13 Electrical Installation Manual U-0 Control Rev. -0- Part #-0-0 Terminal # Symbol Color Description 0 Blue Green/ White* OUT A Gray OUT B Gray OUT C Violet OUT Brown/ Yellow* Red Input terminal signal. Connected to Red () during normal operation. Disconnected from Red () during stop door operation. Will happen if: Switch is turned OFF Slide door is panicked open Input terminal. At fully closed position, input will prevent Slide door from opening. Auxiliary Output terminal Connected to Normally contact on an internal relay. Referred to as Auxiliary Relay Output throughout manual. Used as a Switch to: Sequence an Electric Strike. Control other Slide doors in an air lock situation. Signal a remote computer on the Slide door operation. Auxiliary Output terminal Connected to Normally Closed contact on an internal relay. Auxiliary Output terminal Common for output wire OUT A or OUT B Auxiliary Output terminal Connected to an Internal Transistor with Collector in the U0 Microprocessor Controller. Installer must provide wire for this terminal (not normally utilized). Common terminal Provides common ground for the VDC power and signal source. Section b: Sensor Wire Connections * Color/Color denotes a base wiring Color with a stripe Color. For example: Black/Red indicates a Black wire with a Red Stripe. ** Denotes wiring that has been crimped together at factory. Table - Acusensor U0 arness Extension arness Acusensor arness Red Common Red **White and Red Black Signal, Interior *Black/Red Signal Exterior Yellow Green Brown + VDC Gray Black Identify Operating Wires -

14 Electrical Installation Manual U-0 Control Part #-0-0 Rev. -0- Table - Optex i-one U0 arness Extension arness Optex i-one arness Red Common Red **Gray and White Black Interior Signal *Black/Red Exterior Signal Yellow Yellow Brown + VDC Gray Gray Table - Wizard U0 arness Extension arness Wizard arness Red Common Red **Red and White and Brown Black Interior Signal *Black/Red Exterior Signal Yellow Green and Blue Brown + VDC Gray Black Section c: Rocker Switch Settings OFF = Not switched to COMMON ON = Switched to COMMON ( ) Rocker Switch Mode Key Switch Mode Wire Wire M Wire Description Night Night OFF ON - Sensors on Terminal () and () can not open the door while door is closed. Sensors on Terminal () and () will provide threshold safety when door is in any position other than closed. Electric Lock remains locked unless an activation signal is given from a device (such as card reader, key switch, wall plate, etc.): connected in one of two ways:. Between Common and MO () a. This only works when door is in Night mode. Between Common and () a. This only works if the is programmed for activation devices. Note: Consult the U0 Programming Manual for details; (P/N ). old.o. ON ON - Two Way Auto OFF OFF - No activation needed when old is selected. Slide door is held open. Electric Lock is always unlocked. Sensors on Terminal () and () can both open the door. Electric Lock is always unlocked. - Identify Operating Wires

15 Electrical Installation Manual U-0 Control Rev. -0- Part #-0-0 Rocker Switch Mode Key Switch Mode Wire Wire M Wire One Way Exit ON OFF - Full Full - - OFF Reduced Reduced - - ON Note: Description Sensor on Terminal () can open the door. Sensor is normally Interior and used to activate door for one-way traffic. Sensor on Terminal () can not open the door from the closed position. Sensor is normally Exterior and used to provide threshold safety only. Electric Lock remains locked unless an activation occurs from the interior sensor or by a device (such as a card reader, key switch, wall plate, etc.) that is connected in one of two ways:. Between Common and M () a. This only works when door is in One Way or Exit mode.. Between Common and () a. This only works if the is programmed for activation devices. Consult the U0 Programming Manual for details; (P/N ). Upon activation or in old mode, Slide door will open to the full position. Upon activation, Slide door will open to the Reduced position. Identify Operating Wires -

16 GYRO TEC DS-00 TO 0 B RELATED DEVICES P MADE IN JAPAN B M OU T 0 POWER P 0VAC 0/0z INDICATORS 0 0 Electrical Installation Manual U-0 Control Part #-0-0 Rev. -0- CAPTER : WIRING DIAGRAMS Section a: () Acusensors and () olding Beam U0 MICROPROCESSOR CONTROL P/N -0-0 Black Wire (ot) MOTOR/OPERATOR P/N - P/N - WARNING ANDY TERMINAL P Microprocessor Controller 0- FUNCTION (SLIDING DOOR) SYMBOL VDC + DCV VDC-(Common) Interior Ac va o n olding Beam Mode Switch (see Mode SW Usage shown le ) Exterio r Ac va on Sequen al Ac va on Contact Output (Class Load only) OUT. A 0V(.Vpeak)max OUT. B Amax.(0-0V),.Amax.(0-0V) Common OUT. C Auxiliary Output (-Collector) VDC-(Common) T NOISE FILTER L To protect against risk of Fire or electric shock,use only the cer fied power supply. Mode SW Usage M MODE TWO WAY ONE WAY OLD OPEN NIG T MOTOR P >POM< N POWER PE ACV ± 0% 0 / 0 z U0 TERMINAL P/N - GYRO TEC TB TB D-0 Nabtesco Corporation LOAD Adjustments to the door can only be made with the andy Terminal. ERROR ASSEMBLY P/N 0000 ENTRANCES, INC. - -CIRCUIT- -BREAKER- INDICATES POWER IS OFF PRESS RESET Do not disassemble the control box. There are no user serviceable parts inside. To maintain warranty,repairs must be made by authorized facilities. S White Wire (Common) Power arness P/N - OFF Power Switch Grounding Wire P/N - MAIN ARNESS FOR U0 P/N - Auxiliary 0 VAC Power Wires (These wires are normally BLACK ORG/WT DC V VDC+ VDC- (Common) Related Devices - P B M Out.A Out.B Out.C Out olding Beam Mode Switch BLK/ BLK/ YELLOW GRN/WT 0 0 Common Contact Output (Class Load only) 0V (.V peak) max. A max, (0-0V),.A max. (0-0V) U0 TERMINAL Auxiliary Output ( Collector) VDC Common U0 MICROPROCESSOR CONTROL LABEL & (CIRCUIT & ) TERM # KEY SWITC FOR U0 PN - TERM # TERM # ROCKER SWITC FOR U0 PN - CK SIDE OF ROCKER SWITC SOWN BLK Optex OS-C Controller MAGNETIC POWER DOWN SWITC P/N - ON OFF OPTEX OLDING BEAM CONTROLLER PT. NO. PN -0-0 NIGT YELLOW YELLOW ORG/WT ORG/WT TWO WAY ACUSENSOR EXTENSION ARNESS PN --00 ACUSENSOR EXTENSION ARNESS PN --00 ONE WAY OLD OPEN ORG/WT FULL OPEN DN 0 UCED OPEN EXTERIOR ACUSENSOR PT. NO. -0 INTERIOR ACUSENSOR PT. NO Wiring Diagrams (Surface Applied Sliders)

17 GYRO TEC DS-00 MADE IN JAPAN Electrical Installation Manual U-0 Control Rev. -0- Part #-0-0 Section b: () Optex i-one Sensors and () olding Beam MOTOR/OPERATOR P/N - U0 MICROPROCESSOR CONTROL P/N -0-0 U0 TERMINAL P/N - Power arness P/N - MAIN ARNESS FOR U0 P/N - BLACK ORG/WT BLK/ BLK/ YELLOW GRN/WT TERM # & (CIRCUIT & ) BLK BLK TERM # TERM # Optex OS-C Controller ORG/WT YELLOW ACUSENSOR EXTENSION ARNESS PN --00 YELLOW ACUSENSOR EXTENSION ARNESS PN --00 OPTEX OLDING BEAM CONTROLLER PT. NO. PN -0-0 YELLOW OPTEX ARNESS P/N -0 YELLOW INTERIOR OPTEX I- PT. NO. -0 EXTERIOR OPTEX I- PT. NO. -0 DN 0 TO 0 0 RELATED DEVICES P >POM< POWER P/N - Black Wire (ot) T NOISE FILTER ACV ± 0% 0 / 0 z D-0 TB ANDY TERMINAL P Microprocessor Controller 0- FUNCTION (SLIDING DOOR) SYMBOL VDC + DCV VDC-(Common) Interior Ac va on olding Beam Mode Switch (see Mode SW Usage shown le ) Exterio r Ac va on Sequen al Ac va on Contact Output (Class Load only) OUT. A 0V(.Vpeak)max OUT. B Amax.(0-0V),.Amax.(0-0V) Common OUT. C Auxiliary Output (-Collector) VDC-(Common) TB White Wire (Common) S B M OFF Power Switch Auxiliary 0 VAC Power Wires (These wires are normally Grounding Wire P/N - DC V OU T 0 Nabtesco Corporation ERROR MOTOR P WARNING To protect against risk of Fire or electric shock,use only the cer fied power supply. Mode SW Usage M MODE TWO WAY ONE WAY OLD OPEN NIG T B POWER P 0VAC 0/0z INDICATORS GYRO TEC Adjustments to the door can only be made with the andy Terminal. Do not disassemble the control box. There are no user serviceable parts inside. To maintain warranty,repairs must be made by authorized facilities. B M Out.A Out.B Out.C Out VDC+ VDC- (Common) olding Beam Mode Switch 0 0 L N PE -CIRCUIT- -BREAKER- LOAD INDICATES POWER IS OFF ASSEMBLY P/N 0000 ENTRANCES, INC. - PRESS RESET Related Devices - P 0 Common Contact Output (Class Load only) 0V (.V peak) max. A max, (0-0V),.A max. (0-0V) Auxiliary Output ( Collector) VDC Common U0 TERMINAL U0 MICROPROCESSOR CONTROL LABEL KEY SWITC FOR U0 PN - ROCKER SWITC FOR U0 PN - CK SIDE OF ROCKER SWITC SOWN MAGNETIC POWER DOWN SWITC P/N - ON OFF NIGT ORG/WT TWO WAY ONE WAY OLD OPEN FULL OPEN ORG/WT UCED OPEN Wiring Diagrams (Surface Applied Sliders) -

18 GY RO TEC DS-00 MADE IN JAPAN TO 0 0 POWER P INDICATORS 0VAC 0/0z Electrical Installation Manual U-0 Control Part #-0-0 Rev. -0- Section c: () Acusensors, () olding Beam and () Breakout Beam U0 MICROPROCESSOR CONTROLLER P/N -0-0 WARNING To protect against risk of fire MOTOR P or electric shock,use only the certified power supply. Mode SW Usage POWER MODE TWO WAY GYRO TEC ONE WAY GndG nd OLD OPEN NIGT ERROR Adjustments to the door can only be made with the andy Terminal. Do not disassemble the control box. There are no user serviceable parts inside. To maintain warranty,repairs must be made by authorized facilities. ANDY TERMINAL P Microprocessor Controller 0- FUNCTION [SLIDING DOOR] SYMBOL VDC+ DCV VDC-(Common) Interior Activation olding Beam Mode Switch (see Mode SW Usage shown left) Exterior Activation Sequential Activation Contact Output (Class Load only) OUT.A 0V(.Vpeak)max. OUT.B Amax.(0-0V),.Amax.(0-0V) Common OUT.C Auxiliary Output (-Collector) VDC-(Common) >POM< Power arness (P/N -) Main arness For U0 P/N - BLK/ & (TERM & ) TERM # BLK YELLOW YELLOW ACUSENSOR EXTENSION ARNESS P/N --00 ACUSENSOR EXTENSION ARNESS P/N --00 OPTEX OLDING BEAM CONTROLLER PT. NO. P/N -0-0 DN 0 B Gnd M Gnd RELATED DEVICES P Black Wire (ot) ANDY TERMINAL ARNESS P/N - U0 TERMINAL P/N - (TERM #) (TERM #) (TERM #) (TERM #) & (TERM & ) TERM # OPTEX OS-C OPTEX OS-C Controller Controller MOTOR/OPERATOR P/N - OPTEX BREAKOUT BEAM CONTROLLER PT. NO. P/N -0-0 INTERIOR ACUSENSOR P/N 0 P/N - T EXTERIOR ACUSENSOR P/N 0 NOISE FILTER B M OUT 0 0 L N PE ACV ± 0% 0 / 0 z TB TB D-0 -CIRCUIT- -BREAKER- Nabtesco Corporation LOAD INDICATES POWER IS OFF ASSEMBLY P/N 0000 ENTRANCES, INC. - PRESS RESET S White Wire (Common) OFF Power Switch Auxiliary 0 VAC Power Wires (These wires are normally coiled and ed up) Grounding Wire P/N - BLACK ORG/WT BLK/ DC V Related Devices - P B VDC+ VDC- (Common) Interior Ac va on olding Beam YELLOW GRN/WT 0 0 M Out.A Out.B Out.C Out Common Mode Switch (See Mode SW Usage Shown Le ) Exterior Ac va on Sequen al Ac va on Contact Output (Class Load only) 0V (.V peak) max. A max, (0-0V),.A max. (0-0V) U0 TERMINAL Auxiliary Output ( Collector) VDC Common U0 MICROPROCESSOR CONTROLLER LABEL KEY SWITC FOR U0 P/N - ROCKER SWITC FOR U0 P/N - CK SIDE OF ROCKER SWITC SOWN MAGNETIC POWER DOWN SWITC P/N - ON ROCKER SWITC EXTENSION ARNESS FOR U0 P/N - OFF NIGT ORG/WT ORG/WT TWO WAY ONE WAY OLD OPEN ORG/WT FULL OPEN UCED OPEN - Wiring Diagrams (Surface Applied Sliders)

19 GY RO TEC DS-00 MADE IN JAPAN TO 0 0 Gnd M Gnd POWER P INDICATORS 0VAC 0/0z RELATED DEVICES P B B M OUT 0 0 Electrical Installation Manual U-0 Control Rev. -0- Part #-0-0 Section d: () Optex i-one Sensors, () olding Beam and () Breakout Beam Black Wire (ot) P/N - MOTOR/OPERATOR P/N - ANDY TERMINAL P Microprocessor Controller 0- FUNCTION [SLIDING DOOR] SYMBOL VDC+ DCV VDC-(Common) Interior Activation olding Beam Mode Switch (see Mode SW Usage shown left) Exterior Activation Sequential Activation Contact Output (Class Load only) OUT.A 0V(.Vpeak)max. OUT.B Amax.(0-0V),.Amax.(0-0V) Common OUT.C Auxiliary Output (-Collector) VDC-(Common) WARNING To protect against risk of fire MOTOR P or electric shock,use only the certified power supply. Mode SW Usage POWER MODE TWO WAY GYRO TEC ONE WAY GndG nd OLD OPEN NIGT ERROR Adjustments to the door can only be made with the andy Terminal. Do not disassemble the control box. There are no user serviceable parts inside. To maintain warranty,repairs must be made by authorized facilities. T NOISE FILTER L >POM< N PE ACV ± 0% 0 / 0 z U0 TERMINAL P/N - TB TB D-0 -CIRCUIT- -BREAKER- Nabtesco Corporation LOAD INDICATES POWER IS OFF ASSEMBLY P/N 0000 ENTRANCES, INC. - PRESS RESET S White Wire (Common) U0 MICROPROCESSOR CONTROLLER P/N -0-0 Power arness P/N - Auxiliary 0 VAC Power Wires (These wires are OFF Power Switch Grounding Wire P/N - MAIN ARNESS FOR U0 P/N - BLACK ORG/WT DC V B M Out.A Out.B Out.C Out VDC+ VDC- (Common) Related Devices - P olding Beam Mode Switch BLK/ BLK/ YELLOW GRN/WT 0 (TERM #) 0 (TERM #) Common Contact Output (Class Load only) 0V (.V peak) max. A max, (0-0V),.A max. (0-0V) U0 TERMINAL Auxiliary Output ( Collector) VDC Common U0 MICROPROCESSOR CONTROLLER LABEL & (TERM & ) & (TERM & ) TERM # KEY SWITC FOR U0 PN - TERM # TERM # TERM # ROCKER SWITC FOR U0 PN - CK SIDE OF ROCKER SWITC SOWN BLK Optex OS-C Controller Optex OS-C Controller MAGNETIC POWER DOWN SWITC P/N - ON OFF OPTEX BREAKOUT BEAM CONTROLLER PT. NO. PN -0-0 OPTEX OLDING BEAM CONTROLLER PT. NO. PN -0-0 NIGT YELLOW YELLOW ORG/WT ORG/WT TWO WAY ACUSENSOR EXTENSION ARNESS PN --00 ACUSENSOR EXTENSION ARNESS PN --00 ONE WAY OLD OPEN ORG/WT FULL OPEN ROCKER SWITC EXTENSION ARNESS FOR U0 PN - OPTEX ARNESS PN -0 YELLOW YELLOW UCED OPEN DN 0 EXTERIOR OPTEX I-ONE PN -0-A INTERIOR OPTEX I-ONE PN -0-A Wiring Diagrams (Surface Applied Sliders) -

20 GY RO TEC DS-00 MADE IN JAPAN TO 0 0 Gnd M Gnd POWER P INDICATORS 0VAC 0/0z RELATED DEVICES P B B M OUT 0 0 Electrical Installation Manual U-0 Control Part #-0-0 Rev. -0- Section e: () Wizard G, and () olding Beam Black Wire (ot) P/N - MOTOR/OPERATOR P/N - ANDY TERMINAL P Microprocessor Controller 0- FUNCTION [SLIDING DOOR] SYMBOL VDC+ DCV VDC-(Common) Interior Activation olding Beam Mode Switch (see Mode SW Usage shown left) Exterior Activation Sequential Activation Contact Output (Class Load only) OUT.A 0V(.Vpeak)max. OUT.B Amax.(0-0V),.Amax.(0-0V) Common OUT.C Auxiliary Output (-Collector) VDC-(Common) WARNING To protect against risk of fire MOTOR P or electric shock,use only the certified power supply. Mode SW Usage POWER MODE TWO WAY GYRO TEC ONE WAY GndG nd OLD OPEN NIGT ERROR Adjustments to the door can only be made with the andy Terminal. Do not disassemble the control box. There are no user serviceable parts inside. To maintain warranty,repairs must be made by authorized facilities. T NOISE FILTER L >POM< N PE ACV ± 0% 0 / 0 z U0 TERMINAL P/N - TB TB D-0 -CIRCUIT- -BREAKER- Nabtesco Corporation LOAD INDICATES POWER IS OFF ASSEMBLY P/N 0000 ENTRANCES, INC. - PRESS RESET S White Wire (Common) U0 MICROPROCESSOR CONTROLLER P/N -0-0 Power arness P/N - Auxiliary 0 VAC Power Wires (These wires are OFF Power Switch Grounding Wire P/N - MAIN ARNESS FOR U0 P/N - BLACK ORG/WT DC V VDC+ VDC- (Common) Related Devices - P B M olding Beam Mode Switch BLK/ BLK/ YELLOW GRN/WT 0 0 Out.A Out.B Out.C Common Contact Output (Class Load only) 0V (.V peak) max. A max, (0-0V),.A max. (0-0V) U0 TERMINAL Auxiliary Output ( Collector) Out VDC Common U0 MICROPROCESSOR CONTROL LABEL & (c IRcUIt & ) TERM # KEY SWITC FOR U0 PN - TERM # TERM # ROCKER SWITC FOR U0 PN - CK SIDE OF ROCKER SWITC SOWN BLK Optex OS-C Controller MAGNETIC POWER DOWN SWITC P/N - ON ROCKER SWITC EXTENSION ARNESS FOR U0 PN - OFF OPTEX OLDING BEAM CONTROLLER PT. NO. PN -0-0 NIGT YELLOW YELLOW ORG/WT ORG/WT TWO WAY ACUSENSOR EXTENSION ARNESS PN --00 ACUSENSOR EXTENSION ARNESS PN --00 ONE WAY White and Green wires from Sensor provide output for OLD OPEN ORG/WT FULL OPEN On Remote Control Set: F to If programming without the Remote: Parameter to UCED OPEN BLACK BLACK DN 0 WIZARD G PN -0 WIZARD G PN -0 - Wiring Diagrams (Surface Applied Sliders)

21 GY RO TEC DS-00 MADE IN JAPAN TO 0 0 B Gnd M Gnd POWER P INDICATORS 0VAC 0/0z RELATED DEVICES P B M OUT 0 0 Electrical Installation Manual U-0 Control Rev. -0- Part #-0-0 Section f: () Wizard G, () olding Beam and () Breakout Beam Black Wire (ot) P/N - MOTOR/OPERATOR P/N - ANDY TERMINAL P Microprocessor Controller 0- FUNCTION [SLIDING DOOR] SYMBOL VDC+ DCV VDC-(Common) Interior Activation olding Beam Mode Switch (see Mode SW Usage shown left) Exterior Activation Sequential Activation Contact Output (Class Load only) OUT.A 0V(.Vpeak)max. OUT.B Amax.(0-0V),.Amax.(0-0V) Common OUT.C Auxiliary Output (-Collector) VDC-(Common) WARNING To protect against risk of fire MOTOR P or electric shock,use only the certified power supply. Mode SW Usage POWER MODE TWO WAY GYRO TEC ONE WAY GndG nd OLD OPEN NIGT ERROR Adjustments to the door can only be made with the andy Terminal. Do not disassemble the control box. There are no user serviceable parts inside. To maintain warranty,repairs must be made by authorized facilities. T NOISE FILTER L >POM< N PE ACV ± 0% 0 / 0 z U0 TERMINAL P/N - TB TB D-0 -CIRCUIT- -BREAKER- Nabtesco Corporation LOAD INDICATES POWER IS OFF ASSEMBLY P/N 0000 ENTRANCES, INC. - PRESS RESET S White Wire (Common) U0 MICROPROCESSOR CONTROLLER P/N -0-0 Power arness P/N - Auxiliary 0 VAC Power Wires (These wires are OFF Power Switch Grounding Wire P/N - MAIN ARNESS FOR U0 P/N - BLACK ORG/WT DC V B M Out.A Out.B Out.C Out VDC+ VDC- (Common) Related Devices - P olding Beam Mode Switch BLK/ BLK/ YELLOW GRN/WT 0 (TERM #) 0 (TERM #) Common Contact Output (Class Load only) 0V (.V peak) max. A max, (0-0V),.A max. (0-0V) U0 TERMINAL Auxiliary Output ( Collector) VDC Common U0 MICROPROCESSOR CONTROLLER LABEL & (TERM & ) & (TERM & ) TERM # KEY SWITC FOR U0 PN - TERM # TERM # TERM # ROCKER SWITC FOR U0 PN - CK SIDE OF ROCKER SWITC SOWN BLK Optex OS-C Controller Optex OS-C Controller MAGNETIC POWER DOWN SWITC P/N - ON ROCKER SWITC EXTENSION ARNESS FOR U0 PN - OFF OPTEX BREAKOUT BEAM CONTROLLER PT. NO. PN -0-0 OPTEX OLDING BEAM CONTROLLER PT. NO. PN -0-0 NIGT YELLOW YELLOW ORG/WT ORG/WT TWO WAY ACUSENSOR EXTENSION ARNESS PN --00 ACUSENSOR EXTENSION ARNESS PN --00 ONE WAY White and Green wires from Sensor provide output for OLD OPEN ORG/WT FULL OPEN On Remote Control Set: F to If programming without the Remote: Parameter to UCED OPEN BLACK BLACK DN 0 WIZARD G PN -0 WIZARD G PN -0 Wiring Diagrams (Surface Applied Sliders) -

22 L N -CIRCUIT- -BREAKER- INDICATES POWER IS OFF PRESS TO RESET ASSEMBLY P/N ENTRANCES, INC. GYRO TEC MADE IN JAPAN 0 0 POWER B ERROR MOTOR P GYRO TEC To protect against risk of Fire or electric shock,use only the cer fied power supply. Mode SW Usage M MODE TWO WAY ONE WAY Adjustments to the door can only be made with the andy Terminal. Do not disassemble the control box. There are no user serviceable parts inside. To maintain warranty,repairs must be made by authorized facilities. NIG T OLD OPEN FUNCTION (SLIDING DOOR) VDC + VDC-(Common) Interior Ac va on olding Beam Mode Switch (see Mode SW Usage shown le ) Exterio r Ac va on Sequen al Ac va on Contact Output (Class Load only) 0V(.Vpeak)max VDC-(Common) ANDY TERMINAL P SYMBOL DCV B M 0 OUT. A OUT. B Common OUT. C OU T Electrical Installation Manual U-0 Control Part #-0-0 Rev. -0- CAPTER : INFRA BEAM WIRING Section a: Wiring () olding Beam On GT- Slide doors, the Optex OS-C Module Infrared Beam is installed and wired at the factory. This unit is shipped complete with the following: Emitter Receiver Control Box Both the Emitter and Receiver are flush mounted on both sides of the Slide door Frame or each Jamb tube, directly across from each other. A pulsed, infrared light beam is used to continuously transmit across the Slide door opening. Interruption of the infrared light beam will switch the White holding beam input wire to Red (Common). Thus causing the system to re-activate and old until the interruption is cleared. Please Figure -. ACV ± 0% 0 / 0 z PE TB P/N - NOISE FILTER S LOAD T TB MOTOR/OPERATOR P/N - DS-00 D-0 Nabtesco Corporation >POM< U0 MICROPROCESSOR CONTROL P/N -0-0 INDICATORS POWER P 0VAC 0/0z WARNING Microprocessor Controller 0- Auxiliary Output (-Collector) Amax.(0-0V),.Amax.(0-0V) RELATED DEVICES P VDC+ VDC- (Common) olding Beam Mode Switch Contact Output (Class Load only) 0V (.V peak) max. A max, (0-0V),.A max. (0-0V) Common Auxiliary Output ( Collector) VDC Common U0 MICROPROCESSOR CONTROL LABEL DC V B M Out.A Out.B Out.C Out 0 Related Devices - P 0 U0 TERMINAL P/N - TERM # & CIRCUIT & Optex OS-C Controller P/N -0-0 TERM # Yellow Braided Shield CONNECT EAC TERMINAL TE SAME Jacket Color TERM # TERM # DN 0 YELLOW TERM # TERM #0 TERM # YELLOW TERM # OTER WIRES NOT SOWN FOR SIMPLICITY EMTR RCVR Figure - () olding Beam using Optex OS-C Controller -0 Infrared Beam Wiring

23 Electrical Installation Manual U-0 Control Rev. -0- Part #-0-0 Section b: Wiring () olding Beams On GT- Slide doors, the Optex OS-C Module Infrared Beam is installed and wired at the factory. This unit is shipped complete with the following: Emitter Receiver Control Box Both the Emitters and Receivers are flush mounted on both sides of the Slide door Frame or each Jamb tube, directly across from each other (in pairs). Please see Figure - and Figure -. Emit Rcvr DN 0 Rcvr Emit Figure - Transmission of Infrared Light Beams A pulsed, infrared light beam is used to continuously transmit across the Slide door opening. Interruption of the infrared light beam will switch the White holding beam input wire to Red (Common). Thus causing the system to re-activate and old until the interruption is cleared. TO U0 CONTROLLER TERMINAL TO AUXILIARY POWER SUPPLY TERM # TERM # CONNECT EAC TERMINAL TE SAME Yellow Jacket Color Optex OS-C Controller P/N -0-0 Braided Shield Plas c Conductor YELLOW TERM # TERM # TERM # TERM # TERM # YELLOW TERM # TERM #0 YELLOW TERM # TERM # YELLOW TERM # RCVR EMTR OTER WIRES NOT SOWN FOR SIMPLICITY DN 0 EMTR RCVR Figure - () olding Beams using Optex OS-C Controller Infrared Beam Wiring -

24 L N -CIRCUIT- -BREAKER- INDICATES POWER IS OFF PRESS TO RESET ASSEMBLY P/N ENTRANCES, INC. GYRO TEC MADE IN JAPAN 0 0 POWER B ERROR MOTOR P GYRO TEC To protect against risk of Fire or electric shock,use only the cer fied power supply. Mode SW Usage M MODE TWO WAY ONE WAY Adjustments to the door can only be made with the andy Terminal. Do not disassemble the control box. There are no user serviceable parts inside. To maintain warranty,repairs must be made by authorized facilities. NIG T OLD OPEN FUNCTION (SLIDING DOOR) VDC + VDC-(Common) Interior Ac va on olding Beam Mode Switch (see Mode SW Usage shown le ) Exterio r Ac va on Sequen al Ac va on Contact Output (Class Load only) 0V(.Vpeak)max VDC-(Common) ANDY TERMINAL P SYMBOL DCV B M 0 OUT. A OUT. B Common OUT. C OU T Electrical Installation Manual U-0 Control Part #-0-0 Rev. -0- Section c: Wiring olding Beam for Breakout On GT- Slide doors, the Optex OS-C Module Infrared Beam is installed and wired at the factory. This unit is shipped complete with the following: Emitter Receiver Control Box Both the Emitter and Receiver are flush mounted on both sides of the Slide door Frame or each Jamb tube, directly across from each other. A pulsed, infrared light beam is used to continuously transmit across the Slide door opening. Interruption of the infrared light beam. By Breaking Out a Slide door panel the Blue () wire power down loop will be interrupted. Thus causing the system to stop operating until the Slide door is repositioned and latched. Please see Figure -. ACV ± 0% 0 / 0 z PE TB P/N - NOISE FILTER S LOAD T TB MOTOR/OPERATOR P/N - DS-00 D-0 Nabtesco Corporation >POM< U0 MICROPROCESSOR CONTROL P/N -0-0 INDICATORS POWER P 0VAC 0/0z WARNING Microprocessor Controller 0- Auxiliary Output (-Collector) Amax.(0-0V),.Amax.(0-0V) RELATED DEVICES P VDC+ VDC- (Common) olding Beam Mode Switch Contact Output (Class Load only) 0V (.V peak) max. A max, (0-0V),.A max. (0-0V) Common Auxiliary Output ( Collector) VDC Common U0 MICROPROCESSOR CONTROL LABEL DC V B M Out.A Out.B Out.C Out 0 Related Devices - P 0 U0 TERMINAL P/N - TERM # & CIRCUIT & Optex OS-C Controller P/N -0-0 TERM # Yellow Braided Shield CONNECT EAC TERMINAL TE SAME Jacket Color TERM # TERM # DN 0 YELLOW TERM # TERM #0 TERM # YELLOW TERM # OTER WIRES NOT SOWN FOR SIMPLICITY EMTR RCVR Figure - Breakout Beam using Optex OS-C Controller - Infrared Beam Wiring

25 Electrical Installation Manual U-0 Control Rev. -0- Part #-0-0 CAPTER : ELECTRIC LOCK WIRING Note: Electric Locks can not prevent Breakout. If preventing Breakout is deemed necessary, panic hardware must be fitted to the Door Panels. The Electric Lock is optional and can come in ( of ) configurations: Fail Safe Allows the Door Panel to be manually opened if power is turned Off. Fail Secure Will not allow the Door Panal to be manually opened if power is turned Off. Electric Locks are used to prevent Door Panels from opening until they are activated by the U0 Microprocessor Control when it receives a signal from a: Remote Switch Transmitter Activation Device on the face of the Door Electric Locks are pre-installed at the Factory. Only the Strike mounted on the eader may need to be adjusted. Section a: Adjust the Strike.. Close Door Panel(s).. Go inside the eader. Loosen the Strike Mounting Bolts that is holding the Strike Bracket secure to the eader.. Slide the Strike to align with the Latch Bolt in the fully closed position.. Tighten the Strike Mounting Bolts. a. Do not overtighten. Electric Lock Assembly LATCBOLT POSITION: BI PART UNITS L SINGLE F.O. R SINGLE F.S. LATCBOLT POSITION: R SINGLE F.O. L SINGLE F.S. Electric Strike Slight Gap (Between Strike Wall and Dead Bolt) Belt Clip Dead Bolt Assembly Dead Bolt Engaged with Electric Strike (Door in Full Closed Posi on) Terminal Strip (Strike Side of Door) DN 0 Figure - Adjust the Strike Electric Lock Wiring -

26 0 Electrical Installation Manual U-0 Control Part #-0-0 Rev. -0- Section b: Note: U0 with Fail Safe Electric Lock Fail Safe Electric Lock only works in One Way mode or Night Mode. GYRO TEC DS-0 - MADE IN JAPAN ACV ± 0% 0 / 0 z BLACK (OT) (COMMON) GROUND LUG SCREW TO EADER OFF POWER SWITC 0 VAC VDC+ VDC-(COMMON) INTERIOR ACTIVATION OLDING BEAM Exterior Activation Sequential Activation FUNCTION [SLIDING DOOR] UCED OPENING SWITC Mode Switch (see Mode SW Usage shown left) Contact Output (Class Load only) 0V(.Vpeak)max. Amax.(0-0V),.Amax.(0-0V) Auxiliary Output (-Collector) VDC-COMMON Common M OUT.A OUT.B OUT.C OUT SYMBOL DCV B RELATED DEVICES - P TRANSFORMER TB S LABEL ON U0 CONTROL 0 0 U0 ELECTRIC STRIKE OUTPUT SIGNAL ANDY TERMINAL: AUX OUTPUT = 0, OUTPUT TIMER =, ROCKER SWITC SETTING: ONE WAY OR NIGT MODE ON OUTPUT: 0 = ELECTRIC STRIKE OUTPUT OUTPUT TIMER 0 =(DO NOT USE) =(DO NOT USE) =(DO NOT USE) = ELECTRIC STRIKE FUNCTION ACTIVATION SIGNAL OUTPUT SIGNAL OUTPUT TIMER.0 SEC OFF OFF FULLY CLOSED SEC OPENING FULL OPEN ON CLOSING FULLY CLOSED A M P P/N - NOISE FILTER T ZNR ZNR TB MOTOR/OPERATOR P/N - U0 CONTROL P/N GROUND ARNESS P/N - AUXILIARY 0 VAC POWER WIRES (TESE WIRES NORMALLY COILED AND TIED UP) ARNESS P/N - TERMINAL ON U0 MAIN ARNESS WIRING FOR ELECTRIC LOCK ONLY SOWN P/N - VIOLET FAIL SAFE LOCK ASSY. P.N ANDY TERMINAL ARNESS P/N - POWER B GYRO TEC >POM< BLK WT GRY VIO 0V FAIL SAFE 0 Mode SW Usage M MODE TWO WAY Gnd ONE WAY Gnd Gnd OLD OPEN Gnd NIGT Adjustments to the door can only be made with the andy Terminal. Do not disassemble the control box. There are no user serviceable parts To maintain warranty,repairs must be made by authorized facilities. Microprocessor Controller 0- FUNCTION [SLIDING DOOR] SYMBOL VDC+ DCV VDC-(Common) Interior Activation olding Beam B Mode Switch (see Mode SW Usage shown left) M Exterior Activation Sequential Activation 0 Contact Output (Class Load only) OUT.A 0V(.Vpeak)max. OUT.B Amax.(0-0V),.Amax.(0-0V) Common OUT.C Auxiliary Output (-Collector) OUT VDC-(Common) MOTOR P ERROR WARNING To protect against risk of fire or electric shock,use only the certified power supply. ANDY TERMINAL P POWER P INDICATORS 0VAC 0/0z RELATED DEVICES P FAIL SECURE (OUT A) FAIL SAFE (OUT B) FAIL SECURE LOCK ASSY. P.N OTER WIRES NOT SOWN FOR SIMPLICITY DN 0 - Electric Lock Wiring

27 Electrical Installation Manual U-0 Control Rev. -0- Part #-0-0 Section c: Note: U0 with Fail Secure Electric Lock Fail Secure Electric Lock only works in One Way mode or Night Mode. ANDY TERMINAL ARNESS P/N - P/N - MOTOR/OPERATOR P/N - U0 CONTROL P/N -0-0 GYRO TEC DS-0 - MADE IN JAPAN TRANSFORMER TB S NOISE FILTER T TB MOTOR P POWER B GYRO TEC Mode SW Usage M MODE TWO WAY Gnd ONE WAY Gnd Gnd OLD OPEN Gnd NIGT Microprocessor Controller 0- FUNCTION [SLIDING DOOR] SYMBOL VDC+ DCV VDC-(Common) Interior Activation olding Beam B Mode Switch (see Mode SW Usage shown left) M Exterior Activation Sequential Activation 0 Contact Output (Class Load only) OUT.A 0V(.Vpeak)max. OUT.B Amax.(0-0V),.Amax.(0-0V) Common OUT.C Auxiliary Output (-Collector) OUT VDC-(Common) ACV ± 0% 0 / 0 z BLACK (OT) (COMMON) OFF POWER SWITC 0 VAC GROUND LUG SCREW TO EADER LABEL ON U0 CONTROL A M P POWER P INDICATORS 0VAC 0/0z ZNR ZNR ERROR WARNING To protect against risk of fire or electric shock,use only the certified power supply. Adjustments to the door can only be made with the andy Terminal. Do not disassemble the control box. There are no user serviceable parts inside. To maintain warranty,repairs must be made by authorized facilities. ANDY TERMINAL P 0 ARNESS P/N - GROUND ARNESS P/N - AUXILIARY 0 VAC POWER WIRES (TESE WIRES NORMALLY COILED AND TIED UP) (OUT A) VIOLET TERMINAL ON U0 MAIN ARNESS WIRING FOR ELECTRIC LOCK ONLY SOWN FAIL SECURE LOCK ASSY. P/N - P.N BLK WT GRY VIO 0V FAIL SECURE U0 ELECTRIC STRIKE OUTPUT SIGNAL ANDY TERMINAL: AUX OUTPUT = 0, OUTPUT TIMER =, ROCKER SWITC SETTING: ONE WAY OR NIGT MODE ON OUTPUT: 0 = ELECTRIC STRIKE OUTPUT OUTPUT TIMER 0 = (DO NOT USE) = (DO NOT USE) = (DO NOT USE) = ELECTRIC STRIKE FUNCTION ACTIVATION SIGNAL OUTPUT SIGNAL OUTPUT TIMER.0 SEC OFF OFF FULLY CLOSED ON SEC OPENING FULL OPEN CLOSING FULLY CLOSED RELATED DEVICES P VDC+ VDC-(COMMON) INTERIOR ACTIVATION OLDING BEAM Exterior Activation Sequential Activation FUNCTION [SLIDING DOOR] UCED OPENING SWITC Mode Switch (see Mode SW Usage shown left) Contact Output (Class Load only) 0V(.Vpeak)max. Amax.(0-0V),.Amax.(0-0V) Auxiliary Output (-Collector) VDC-COMMON Common M OUT.A OUT.B OUT.C OUT SYMBOL DCV B RELATED DEVICES - P 0 0 DN 0 Electric Lock Wiring -

Turn OFF all power to the Automatic Door if a Safety System is not working.

Turn OFF all power to the Automatic Door if a Safety System is not working. This document is meant to serve as a Quick Set-Up Guide only. Installation manuals referenced below should be downloaded from the NABCO Website and reviewed for complete installation instructions. GT U-0

More information

Swing Door Operator Wiring and Adjustment Manual ** with Magnum 4A Control*

Swing Door Operator Wiring and Adjustment Manual ** with Magnum 4A Control* S82 W18717 Gemini Drive Muskego, Wisconsin 53150 Phone: (877) 622-2694 ax: (888) 679-3319 www.nabcoentrances.com Technical Support: (866) 622-8325 Swing Door Operator Wiring and Adjustment Manual ** with

More information

Setup and Programming Manual

Setup and Programming Manual Microprocessor and Handy Terminal Setup and Programming Manual Versions U04 to U19 for Sliding Door Systems P/N 159000 Rev 7-2-07 The manufacturer, NABCO Entrances, Inc. suggests that this manual be given

More information

Automatic Entrance Systems

Automatic Entrance Systems ON NIGHT ONE W A Y HOLD OPEN FULL OPEN UCED OPEN 890 Microprocessor Controller Power Connector ( pin) Main Harness Connector ( pin) Motor Connector ( pin) CAUTION Fuse Inside. Adjustments to the door can

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI II 1400-6 ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI ACSI 1426-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1092, REV. C INSTALLATION For C-UL Listed applications,

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information

GT 710. Surface-Mounted, Low Energy, ADA*, Fire-Rated Swing Door Operator PRODUCT FEATURES

GT 710. Surface-Mounted, Low Energy, ADA*, Fire-Rated Swing Door Operator PRODUCT FEATURES GT 710 Surface-Mounted, Low Energy, ADA*, Fire-Rated Swing Door Operator The GT 710 operates in both automatic and manual modes. It features a 2-60 second hold-open range and a push-n-go feature. The GT

More information

Section E Fixed Sidelight All Glass. Header Showing U04 to U19 Drive Train Door Panels DS150 and U30 Drive Train...

Section E Fixed Sidelight All Glass. Header Showing U04 to U19 Drive Train Door Panels DS150 and U30 Drive Train... Section E1 1 Fixed Sidelight All Glass Header Showing U0 to U19 Drive Train................................................... 3- Door Panels........................................................................

More information

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide 7002-0289-00 Instruction Bulletin HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment

More information

Gyro Tech Swing Door Conversion Unit (C.U.) Hardware Installation and Service Manual

Gyro Tech Swing Door Conversion Unit (C.U.) Hardware Installation and Service Manual S82 W18717 Gemini Drive PO Box 906 Muskego, WI 53150 Phone: (877) 622-2694 Fax: (888) 679-3319 www.nabcoentrances.com Gyro Tech Swing Door Conversion Unit (C.U.) Hardware Installation and Service Manual

More information

Allen-Bradley HP Inverting Fault Circuit Breaker Kit

Allen-Bradley HP Inverting Fault Circuit Breaker Kit Allen-Bradley 1397 400-600HP Inverting Fault Circuit Breaker Kit Cat. Nos. 1397-IFB600 What This Option Provides This option is intended to be applied to regenerative 1397 drives with high inertia loads.

More information

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY 00 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) Track Assembly (0-) / Replacement

More information

GLM SERIES CONTROL Users Manual Rev:

GLM SERIES CONTROL Users Manual Rev: GLM SERIES CONTROL Users Manual Rev: 808062 Connecting Power Page 2 Motor Terminal Wiring Diagrams Page 3 Getting Started / Setup Page 4 1. Obstruction Detection Devices Page 4 2. Checking Power and Direction

More information

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING CAUTION 80-957-00-00 (08-0) Series 570 Door Openings 85 to 0 or to 80 Adjustable Arm and Slide Track Application Maximum Hinge Side Frame Reveal to /8 (mm) Hinge (Pull) Side of Door Installation 5700 LEO

More information

poollux Power plx-pw60 & plx-pw100

poollux Power plx-pw60 & plx-pw100 poollux Power plx-pw60 & plx-pw100 ETL LISTED Conforms to UL STD 379; Certifi.ed.to.CSA.STD.C22.2.#218.1 5005508 Installation Instructions Read all instructions before attempting to perform installation

More information

Model 2300JL Installation Guide

Model 2300JL Installation Guide Model 2300JL Installation Guide POWER ACCESS CORPORATION 4 HERSHEY DRIVE, DOCK 4 ANSONIA, CT 06401 800-344-0088 WEBSITE: www.power-access.com EMAIL: salesinfo@power-access.com 1 STANDARD PARTS MODEL 2300JL

More information

SX-16 Nightsun Searchlight Safety and Service Bulletin # SL

SX-16 Nightsun Searchlight Safety and Service Bulletin # SL SX-16 Nightsun Searchlight Safety and Service Bulletin # SL 0898-02 Issue Date: 09/25/98 Amended Date: 02/09/06 Subject: SX-16 Nightsun Junction Box Wiring Modification Affected Products: All SX-16 Nightsun

More information

Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel. Model N Installation Guide

Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel. Model N Installation Guide Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel Model 009-8004-0100N Installation Guide Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel Model 009-8004-0100N Installation Guide, Part Number 123759-3 Copyright 2011, Telect,

More information

3 Phase Smart Controller

3 Phase Smart Controller 3 Phase Smart Controller Installation and Owner s Manual STP-SCIII 208-230 VAC, 60Hz, 120 Volt Coil Franklin Fueling 3760 Marsh Rd. Madison WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838

More information

Owner's/Installation Manual

Owner's/Installation Manual Owner's/Installation Manual Power Management Module (PMM) and Starter Kit NOTE: The starter kit must be purchased and installed prior to individual PMM usage. Model Numbers: 00686-0 PMM 00699-0 PMM WITH

More information

CENTRIFLOW METER and ELECTRONICS WIRING and INSTALLATION MANUAL REV 01/16 ORIGINAL LANGUAGE Copyright 2016 Eastern Instrument Laboratories, Inc. All Rights Reserved. TABLE OF CONTENTS SAFETY Safe Operation...

More information

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-10 ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS Features: Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit Protection Standby Battery

More information

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY 0 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) / Replacement Motor Key (00KEY) Rod

More information

Electro-Mechanical Swing Operator. Table of Contents

Electro-Mechanical Swing Operator. Table of Contents *640072* 640072 Electro-Mechanical Swing Operator Models 8230 & 8240 Installation Instructions Table of Contents General...1 Replacement Parts & System Components...1 1 Pre-Installation Site & Product

More information

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B)

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B) Spring-Set Disc Brakes P/N 8-078-98-0 effective 6/6/0 Installation and Service Instructions for 87,000 & 87,00 Series Self-Adjust Brakes (rev. B) Tools required for installation and servicing: 3/8 hex

More information

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS PowerMaster TABLE OF CONTENTS MODEL MBG MEDIUM DUTY BARRIER GATE OPERATOR Important Safety Information...... 3 System Designer Safety Instructions.......4 Installer Safety Instructions....... 5 Installation

More information

6100 Series Swing Door Operator Installation Instructions

6100 Series Swing Door Operator Installation Instructions 6100 Series Swing Door Operator Installation Instructions The manufacturer s specifications for this product require the installation to be approved by an AAADM certified inspector. -USA 4324 Phil Hargett

More information

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING CAUTION 80-957-00-00 (08-0) Series 570 Openings 85 to 0 or to 70 Double Lever Arm Application for Frame Reveals (76) to 7 (78mm)* Stop (Push) Side of Installation 5700 LEO Operator Installation Instructions

More information

Model 2300DL Installation Guide

Model 2300DL Installation Guide Model 2300DL Installation Guide POWER ACCESS CORPORATION 4 HERSHEY DRIVE, DOCK 4 ANSONIA, CT 06401 800-344-0088 WEBSITE: www.power-access.com EMAIL: salesinfo@power-access.com 1 STANDARD PARTS MODEL 2300DL

More information

Differential Pressure Transmitter

Differential Pressure Transmitter Specifications/Instructions Differential Pressure Transmitter General Model PY9000D is a differential pressure transmitter that uses a ceramic cantilever sensor. Deflection of the ceramic cantilever caused

More information

Senior Swing Control Box. Table of Contents

Senior Swing Control Box. Table of Contents *740100* 740100 2800 Overhead Consealed Series 9500 Surface Applied Series Senior Swing Control Box Installation Instructions important These instructions are presented in step-by-step sequence. It is

More information

User s Manual. Automatic Switch-Mode Battery Charger

User s Manual. Automatic Switch-Mode Battery Charger User s Manual Automatic Switch-Mode Battery Charger IMPORTANT Read, understand, and follow these safety rules and operating instructions before using this battery charger. Only authorized and trained service

More information

Patient Care Facility

Patient Care Facility ISIMET Patient Care Facility DLA Controller Individual Room Configuration Style 1 W/ Ver 4.41 pcb & Pulse Relay pcb Installation, Operations, Start-up and Maintenance Instructions Meets all Standards for

More information

SERIES VAC Microprocessor Based Direct Spark Ignition Control FEATURES DESCRIPTION APPLICATIONS THE TOTAL SOLUTION FOR GAS IGNITION CONTROL

SERIES VAC Microprocessor Based Direct Spark Ignition Control FEATURES DESCRIPTION APPLICATIONS THE TOTAL SOLUTION FOR GAS IGNITION CONTROL SERIES 35-72 120 VAC Microprocessor Based Direct Spark Ignition Control 35.72.03 FEATURES Two Mounting Configurations Open Board With Stand-Off's - saves space and cost Potted - protection for washdown

More information

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions ISIMET Drug Testing Labs DLA Controller Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions Meets all Standards for Canadian Industrial Control

More information

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls P-269-89-0408 Installation Installation & Operating Instructions Contents Introduction........................... 2 Specifications.........................

More information

LED Downlight Ceiling Fixtures

LED Downlight Ceiling Fixtures ED Downlight Ceiling Fixtures Every attempt has been made to ensure that this documentation is as accurate and up-to-date as possible. However, Vertical Express assumes no liability for consequences, directly

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Series 2001 Belt Drive Slide Door & RapidSlide INSTALLATION INSTRUCTIONS To be used with H202 C2150 Ver.2 Control Setup Instructions G2001, FEB 2004 CONTENTS 1. Instructions to installer... G2001.1 2.

More information

Installation and Service Instructions for 87,000 Series Manual Adjust Brakes (rev. B)

Installation and Service Instructions for 87,000 Series Manual Adjust Brakes (rev. B) Spring-Set Disc Brakes P/N 8-078-98-06 effective /7/ Installation and Service Instructions for 87,000 Series Manual Adjust Brakes (rev. B) Tools required for installation and servicing: 3/8 hex wrench

More information

L5000 Plus. Installation & Setup Guide

L5000 Plus. Installation & Setup Guide L5000 Plus Page 1 of 16 JDE1945 IssB s1 May 2009 Contents Description Page Safety... 3 Installation Standards 4 Specification. 4 Installation Procedure Pump Box. 6 Auxiliary Pump Boxes... 7 Connecting

More information

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER KEW6201A CONTENTS 1. Safe testing 1 2. Procedure of removing cover. 3 2.1 Method of removing the cover. 3 2.2 Method of storing the cover. 3 3. Product summary

More information

Par ts Manual Z-45/25 TM Z-45/25J. Par ts and Service Supplement. Positive Air Shutdown Valve. Serial Number Range

Par ts Manual Z-45/25 TM Z-45/25J. Par ts and Service Supplement. Positive Air Shutdown Valve. Serial Number Range Par ts Manual Par ts and Service Supplement Positive Air Shutdown Valve Serial Number Range TM Z-45/25 TM Z-45/25J Serial Number Range from Z452513A-47001 Part No. 161517 Rev B1 January 2016 Introduction

More information

Installation Instructions

Installation Instructions 00A0, 0A0-0A0 080A00 08A00 For Use With Vertical EconoMi$ert IV or EconoMi$ert Only SMALL ROOFTOP UNITS ACCESSORY VERTICAL EXHAUST GAS HEATING/ELECTRIC COOLING, ELECTRIC COOLING, AND HEAT PUMP UNITS TO5TON

More information

Series 2003T. Belt Drive Telescoping Slide Door INSTALLATION INSTRUCTIONS. To be used with H210 C2150 Ver.10 Control Setup Instructions

Series 2003T. Belt Drive Telescoping Slide Door INSTALLATION INSTRUCTIONS. To be used with H210 C2150 Ver.10 Control Setup Instructions Series 2003T Belt Drive Telescoping Slide Door INSTALLATION INSTRUCTIONS To be used with H210 C2150 Ver.10 Control Setup Instructions DIRECTION OF DOOR OPENING G230T, JUNE 2009 A U T O M A T I C S G230T.1

More information

LP-2500/2600. Installation and Setup Guide. Lighting Control Panels. Revision 3.1 July 1999

LP-2500/2600. Installation and Setup Guide. Lighting Control Panels. Revision 3.1 July 1999 /2600 Lighting Control Panels Installation and Setup Guide Revision 3. July 999 Phone:770-429-3043 http://www.triateklighting.com sales@triateklighting.com Installation Guide /2600 Lighting Panels Table

More information

FIRE DOOR OPERATOR WARNING INSTALLATION LOGIC BOARD REPLACEMENT KIT K , K A-400 & K B-400 APPLICATION REMOVE AC AND DC POWER

FIRE DOOR OPERATOR WARNING INSTALLATION LOGIC BOARD REPLACEMENT KIT K , K A-400 & K B-400 APPLICATION REMOVE AC AND DC POWER APPLICATION Replacement of logic board for Models FDO and FDC operators with Rev. 400 wiring. FIRE DOOR OPERATOR LOGIC BOARD REPLACEMENT KIT K79-3493-400, K79-3493A-400 & K79-3493B-400 WARNING To prevent

More information

Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin

Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin Technical Bulletin NABCO ENTRANCES TECHNICAL BULLETIN S82 W18717 Gemini Drive Muskego,

More information

TOWA SEIDEN INDUSTRIAL CO., LTD.

TOWA SEIDEN INDUSTRIAL CO., LTD. INSTRUCTION MANUAL SOUNDING LEVEL METER MODEL: TLX-120AP/200AP Meanings of indications for safety used in this Instruction Manual are as follows. WARNING: Indicates that improper handling assumes the risk

More information

Patient Care Facility

Patient Care Facility ISIMET Patient Care Facility DLA Controller Individual Room Configuration Style 1 W/ Ver 4.41 pcb & Pulse Relay pcb Installation, Operations, Start-up and Maintenance Instructions Meets all Standards for

More information

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions ISIMET Drug Testing Labs DLA Controller Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions Meets all Standards for Canadian Industrial Control

More information

TELEMOTIVE APPENDIX F 10K Stepless Electronic Transfer Switch

TELEMOTIVE APPENDIX F 10K Stepless Electronic Transfer Switch USERS MANUAL TELEMOTIVE APPENDIX F 10K Stepless Electronic Transfer Switch N49 W13650 Campbell Drive Menomonee Falls, WI 53051 Phone: 800-88-8178 Fax: 6-783-3510 Website: www.telemotive.com TCK10KMOD-3

More information

Mitsubishi Turbine: Hybrid XT Control Sensor Retrofit

Mitsubishi Turbine: Hybrid XT Control Sensor Retrofit Mitsubishi Turbine: Hybrid XT Control Sensor Retrofit NIPPON ANEMOMETER TO HYBRID XT ANEMOMETER RETROFIT KIT, MITSUBISHI, NEI (9370) NIPPON YAW VANE TO HYBRID XT VANE RETROFIT KIT, MITSUBISHI, NEI (9371)

More information

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT Supersedes Form145.10-IOM1 (810) Form 145.10-IOM1 (910) LOW-AMBIENT KIT MODELS DSH/KSH/DSV/KSV R-410A AIR CONDITIONING UNITS INSTALLATION INSTRUCTIONS IMPORTANT!

More information

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions Electric Heaters 5 20 kw Small Packaged Products 2 to 5 Tons Accessory Electric Heaters Cancels: IIK 564A-24-2 IIK 564A-24- -02 Installation Instructions Electric Heaters 5 20 kw NOTE: Read the entire instruction manual before

More information

Installing the Switch Chassis

Installing the Switch Chassis Safety, page 1 Installation Options with Racks and Cabinets, page 2 Airflow Considerations, page 2 Installation Guidelines, page 2 Unpacking and Inspecting the Switch, page 3 Installing the Switch, page

More information

LCN AUTOMATIC OPERATORS

LCN AUTOMATIC OPERATORS LCN AUTOMATIC OPERATORS SENIOR 9530 SENIOR 9540 SENIOR 9550 SENIOR 9560 8310 ACCESSORIES LCN ELECTROMECHANICAL POWERED SYSTEMS ELECTROMECHANICAL AUTOMATIC OPERATORS LCN s electromechanical products are

More information

29048, 29049, 29050, 29051, 29052, 20953, 29054,

29048, 29049, 29050, 29051, 29052, 20953, 29054, July 15, 2008 Lit. No. 29225, Rev. 06 29048, 29049, 29050, 29051, 29052, 20953, 29054, 29400-2 HARNESS KIT 3-PORT ISOLATION MODULE LIGHT SYSTEM w/2-plug SYSTEM HARNESSES Installation Instructions Read

More information

SERVICE INSTRUCTIONS

SERVICE INSTRUCTIONS USA SERVICE OFFICE Dometic, LLC 2320 Industrial Parkway Elkhart, IN 46516 574-294-2511 CANADA Dometic, LLC 46 Zatonski, Unit 3 Brantford, ON N3T 5L8 CANADA 519-720-9578 3313107.107 5 BUTTON THERMOSTAT

More information

R & D SPECIALTIES ROTROL I USER'S MANUAL

R & D SPECIALTIES ROTROL I USER'S MANUAL R & D SPECIALTIES ROTROL I USER'S MANUAL TABLE OF CONTENTS INTRODUCTION...2 SPECIFICATIONS...2 CONTROLS AND INDICATORS...3 TIME DELAYS...4 INSTALLATION...5 SYSTEM OPERATION...9 TROUBLESHOOTING...13 OPTIONAL

More information

Product Manual MNX10015 / REV B MODEL SB142, SB242. Dual Output Series Switch Boxes

Product Manual MNX10015 / REV B MODEL SB142, SB242. Dual Output Series Switch Boxes Product Manual MNX10015 / REV B MODEL SB142, SB242 Dual Output Series Switch Boxes Contents Section I Overview Introduction.... 2 Description... 2 Section II Installation Mounting... 3 Electrical Connections...

More information

9200 Revenue Meter. Model Certification Current Inputs. Complies with the accuracy requirements of the ANSI C Revenue Metering Standard

9200 Revenue Meter. Model Certification Current Inputs. Complies with the accuracy requirements of the ANSI C Revenue Metering Standard 9200 Revenue Meter This document applies to 9200 meters with firmware version 205 or greater, and explains how to set up and seal the meter for revenue functionality. Revenue meters provide power measurements

More information

5600 Series Power Operator Installation and Instruction Manual

5600 Series Power Operator Installation and Instruction Manual 5600 Series Power Operator Installation and Instruction Manual 80-956-000-00 (08-) 5 ASSA ABLOY 6 Item No. Description Motor (5600M) Cover (5600COV) Control Inverter (5600IN) Power Supply VDC (5600PS)

More information

SERVICE MANUAL (DOMESTIC & INTERNATIONAL)

SERVICE MANUAL (DOMESTIC & INTERNATIONAL) SERVICE MANUAL (DOMESTIC & INTERNATIONAL) DUAL TECHNOLOGY FINISHER MODEL 1960 & 1980 SERIES Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United States of America Telephone:

More information

YG101 SWING GATE OPENER OWNER S MANUAL

YG101 SWING GATE OPENER OWNER S MANUAL YG101 SWING GATE OPENER OWNER S MANUAL IMPORTANT SAFTEY INFORMATION Installing the YG101 Gate Opener requires wiring of standard 110V electrical lines. This should only be performed by a trained technician.

More information

Sliding Gate Operator User's Manual

Sliding Gate Operator User's Manual Sliding Gate Operator User's Manual PY800AC/PY00AC. Products introduction Please read the instructions carefully before proceeding. MCU is supplied to control the gate operator. Keypad / single button

More information

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B)

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B) Spring-Set Disc Brakes P/N 8-078-98-0 effective 03/6/4 Installation and Service Instructions for 87,000 & 87,00 Series Self-Adjust Brakes (rev. B) Tools required for installation and servicing: 3/8 hex

More information

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications WPC2-XXXX-T Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH

More information

Application Engineering

Application Engineering Application Engineering March 2011 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital compressor or the

More information

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures Installation Instructions Issue Date April 8, 2008 A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures Application IMPORTANT: The A419 Series Electronic Temperature

More information

Model LA 4400 Time Delay OFF Controller

Model LA 4400 Time Delay OFF Controller ISIMET LA Series Model LA 4400 Time Delay OFF Controller Installation, Operation and Maintenance Manual Application: The Time Delay OFF Controller with integral 24-hr. programmable time clock operates

More information

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit R Vehicle Security INSTALLATION MANUAL Model: PLUS-4700 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference;

More information

TOYOTA TUNDRA TVIP V4 Preparation

TOYOTA TUNDRA TVIP V4 Preparation Preparation Part Number: PT398-00100 PT398-00100-AA Conflicts Do not install into vehicles without RKE system. Recommended Sequence of Application Item # Accessory 1 TVIP/RES Any TVIP or RES system 2 XM

More information

SKC400U SLIDING GATE OPENER OWNER S MANUAL

SKC400U SLIDING GATE OPENER OWNER S MANUAL SKC400U SLIDING GATE OPENER OWNER S MANUAL IMPORTANT SAFTEY INFORMATION Installing the SKC400U Gate Opener requires wiring of standard 110V electrical lines. This should only be performed by a trained

More information

USERS GUIDE LO-21U LOCKOUT RELAY

USERS GUIDE LO-21U LOCKOUT RELAY USERS GUIDE LO-21U LOCKOUT RELAY PRODUCT DESCRIPTION The LO-21U (PN: 10LO21U) is a micro-processed lock out module designed to operate on swing door applications with BEA s Bodyguard or DK-12 overhead

More information

DKC400Y AC Sliding Gate Installation Manual. Sliding Gate Opener. Model: DKC400Y. Installation Manual WARNING

DKC400Y AC Sliding Gate Installation Manual. Sliding Gate Opener. Model: DKC400Y. Installation Manual WARNING Sliding Gate Opener Model: DKC400Y Installation Manual WARNING Read and thoroughly understand all instructions before installing or operating this automatic gate opener. Failure to do so may cause serious

More information

3-PHASE SMART CONTROLLER STP-SCIIIC INSTALLATION GUIDE

3-PHASE SMART CONTROLLER STP-SCIIIC INSTALLATION GUIDE 3-PHASE SMART CONTROLLER STP-SCIIIC INSTALLATION GUIDE The information in this publication is provided for reference only. While every effort has been made to ensure the reliability and accuracy of the

More information

Signet Pressure Transmitter

Signet Pressure Transmitter Signet 80 Pressure 80.090 80.090 Rev. J 0/ English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents. Installation.

More information

Electrical Installation

Electrical Installation Electrical Installation Symmetra LX Tower UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva 200 V, 4-16 kva 208/240 V, 4-16 kva 220/230/240 V, 4-16 kva Important Safety Messages SAVE

More information

Installation Instructions

Installation Instructions Quick-Mount Visual Instructions for Mechanical Installation Quick-Mount Visual Instructions 1. Rotate the damper to its failsafe position. If the shaft rotates counterclockwise, mount the CCW side of the

More information

Power Operated Retrofit Kit for Manual Door 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

Power Operated Retrofit Kit for Manual Door 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual Therm-L-Tec Building Systems LLC Therm-L-Tech Power Operated Retrofit Kit for Manual Door 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual Rev. A 10/2014 Index Index 1 Electrical Requirements

More information

E.S.P. Embedded Sensing Probes for Motor Brushes

E.S.P. Embedded Sensing Probes for Motor Brushes E.S.P. Embedded Sensing Probes for Motor Brushes 2/13 Installation & Operating Manual MN609 Any trademarks used in this manual are the property of their respective owners. Important: Be sure to check www.baldor.com

More information

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint Product Identification and Overview The BAPI-Stat Quantum style room temperature sensor features a large format LCD and slider setpoint adjustment. Additional options include button override and communication

More information

Sliding Gate Operator User's Manual

Sliding Gate Operator User's Manual Sliding Gate Operator User's Manual SL600AC. Products introduction Please read the instructions carefully before proceeding. MCU is supplied to control the gate operator. Keypad / single button interface.

More information

QUICK START GUIDE FOR ACCESS CONTROL BOARDS. DX Series Four Door TCP/IP Web Server Controller. Model: ACP-DXEL4

QUICK START GUIDE FOR ACCESS CONTROL BOARDS. DX Series Four Door TCP/IP Web Server Controller. Model: ACP-DXEL4 QUICK START GUIDE FOR ACCESS CONTROL BOARDS DX Series Four Door TCP/IP Web Server Controller Model: ACP-DXEL Table of Contents 0- Introduction 0 - Overview 0. - Package Contents 0. - Installation Requirements

More information

General Description. Product Specification. Document Digital Temperature Interlock

General Description. Product Specification. Document Digital Temperature Interlock Document 474751 Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the

More information

Model LA 4300 Time Delay OFF Controller

Model LA 4300 Time Delay OFF Controller ISIMET LA Series Model LA 4300 Time Delay OFF Controller Installation, Operation and Maintenance Manual Application: The Time Delay OFF Controller operates as a single output controller where the application

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

The full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at

The full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at Installation Manual INTRODUCTION The full WeatherTRAK Flow Installation and Maintenance Manual is available online at www.weathertrak.com General Description A WeatherTRAK Flow combines a hydraulic master

More information

Installation Manual. Frameworx Tel-E-Foul. September 2017 /

Installation Manual. Frameworx Tel-E-Foul. September 2017 / Installation Manual Frameworx Tel-E-Foul September 2017 / 53-900676-000 Frameworx Tel-E-Foul Installation Manual September 2017 by the Brunswick Bowling Products. All rights reserved. Past Revisions: March

More information

Clark Public Utilities Commercial Electric Service Handbook. This page left blank intentionally.

Clark Public Utilities Commercial Electric Service Handbook. This page left blank intentionally. This page left blank intentionally. 38 Chapter 4: Commercial Metering / January 2011 APPENDIX Glossary Approval Acceptable to the authority having jurisdiction. Associated equipment As related to metering

More information

HEATEC TEC-NOTE. Troubleshooting modulation motors

HEATEC TEC-NOTE. Troubleshooting modulation motors HEATEC TEC-NOTE Revised 4-24-07 Troubleshooting modulation motors Purpose This document provides a guide for troubleshooting burner modulation motors (Figure 1), which are commonly called mod motors. They

More information

Installation Instructions

Installation Instructions NOTE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SAFETY CONSIDERATIONS Installing and servicing air conditioning equipment

More information

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2 OPERATING AND MAINTENANCE MANUAL Product: Type: Primary Current Injection Test Set 750ADM mk2 750ADM-H mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge Meadows, Guildford,

More information

REC-11+ REMOTE RECEIVER UNIT

REC-11+ REMOTE RECEIVER UNIT Resetting The Programmable Features The installer may quickly and easily return all 17 programmable features back to the factory settings. Changing individual features were explained in detail in the previous

More information

i-energy i-micro inverter GT260

i-energy i-micro inverter GT260 i-energy i-micro inverter GT260 This installation guide contains important instructions on safety matters and the installation of the i-energy i-micro inverter GT260. Please read this guide carefully and

More information

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions Electric Heaters 5 20 kw Small Packaged Products to 5 Tons Accessory Electric Heaters Cancels: IIK 564A--1 IIK 564A-- 11-01 Installation Instructions Electric Heaters 5 0 kw NOTE: Read the entire instruction manual before starting

More information

Operating Instructions Pedestrian Turnstile Type MPT 33

Operating Instructions Pedestrian Turnstile Type MPT 33 Operating Instructions Pedestrian Turnstile Type MPT 33 Contents 1. Delivery...2 2. Safety...2 3 Description and operation...3 4. Foundation...4-5 5. Assembly and installation...6-9 6. Electrical connection...10-11

More information

29048, 29049, 29050, 29051, 29052, 29053, 29054,

29048, 29049, 29050, 29051, 29052, 29053, 29054, April 15, 2014 Lit. No. 29225, Rev. 11 29048, 29049, 29050, 29051, 29052, 29053, 29054, 29400 5 HARNESS KIT 3 PORT ISOLATION MODULE LIGHT SYSTEM w/2 PLUG SYSTEM HARNESSES Installation Instructions Read

More information

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

Product Overview. Product Identification. Amps One CT Two CTs Three CTs AH06 (optional mounting bracket for small, medium, and large CTs) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information