ABB MEASUREMENT & ANALYTICS DATA SHEET. TBX5 ph, Redox (ORP) sensors with diagnostics

Size: px
Start display at page:

Download "ABB MEASUREMENT & ANALYTICS DATA SHEET. TBX5 ph, Redox (ORP) sensors with diagnostics"

Transcription

1 BB MESUREMENT & NLYTICS DT SHEET TBX ph, Redox (ORP) sensors with diagnostics

2 Measurement made easy The most durable ph / Redox (ORP) sensors in the world Next Step Solid State reference eliminates poisoning, pumping and plugging dvantage series with solution ground rod permits continuous sensor diagnostics Comprehensive selection of measuring electrodes sensors designed to suit all application requirements Combination style construction measuring, reference and temperature elements, all in one compact body Insertion, submersion, flow-through and hot-tap increases flexibility of installation Operating temperatures up to C (8 ) the highest glass temperature limit on the market Operating pressures up to bar ( psi) and higher the highest pressure limit on the market

3 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H The most durable ph / Redox (ORP) sensors in the world well-deserved reputation for ruggedness, longevity and accuracy hallmark the TB(X) series ph / Redox sensors. The sensors are easily applied to most industrial measurement needs. They are renowned for their ability to outperform conventional sensors in the industries toughest process applications. Solid-state Next Step reference technology is the foundation for all TB(X) series electrodes. The totally solid inner reference chamber is charged with potassium chloride (KCl). This non- liquid reference all but eliminates poisoning, plugging and pumping problems that plague conventional liquid, slurry and gel designs. The Next Step dvantage series incorporates a solution ground rod that enables sensor diagnostics. ll measurement functions are combined in one compact body: reference, measuring electrode, temperature sensor and ground rod. Using an integral potted cable, a completely sealed assembly is provided without in-process high impedance connections. These advances in reference design, combined with superior glass electrode technology, result in an industrial sensor with unequalled durability and flexibility Wide variety of sensors for most industrial applications BB offers a wide variety of standard sensors for most applications. These include variations in body style, measuring electrode type and shape, temperature compensator, junction type and shape and cable. Next Step dvantage sensors also allow choice of solution ground and O-ring materials. Durable electrodes The TB(X) electrode design eliminates failures due to thermal stress caused by rapid temperature excursions. Unlike other sensors that use a large inner air bubble for expansion absorption, TB(X) electrodes use a unique inner plunger; providing more effective protection against temperature fluctuations. The glass contains no barium, cobalt or uranium oxides. The impedance is low enough to maintain signal integrity, yet high enough to remain chemically durable with little or no sodium ion (Na + ) error. The electrodes are available in several measuring element types ensuring greatest process optimization. g / gcl element Next Step dvantage solution ground Wood and PTE liquid junction Solution ground interface Electrode Next Step solid state reference Temperature compensator Inner plunger BB TB(X) series sensor construction Electrode types and ratings Code Type Description lat glass High density duty with heavy fouling. Electrode flush with liquid junction. Low Na + error. General-purpose glass High temperature glass or light to medium duty and lower temperature applications. Not for high ph. Versatile and suitable for high and low ph, strong chemicals and high temperature rated cabling. Ratings Range Operating temperatures Impedance at C C (77 ) to ph to 6 to 6 MΩ to ph to to MΩ to ph to to 8 MΩ Redox (ORP) Platinum (Pt) element. to ± mv to to 8 kω Redox (ORP) Gold (u) element. to ± mv to to 8 kω luoride / cid Resistant to etching by up to several percent H and strong acids. to ph to 8 to 76 MΩ J Coating resistant high temperature Versatile and suitable for high and low ph, strong chemicals. Notes. to C ( to ) for sterilization cycles C ( ) maximum recommended for high H concentration to ph to to 8 MΩ

4 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H Body style Sensor bodies are constructed of Kynar (PVD) or Ryton (PPS). TB series sensors use Solid-State Next Step references. The TBX series denotes Next Step dvantage types with integral solution ground. Model number Solid-state Next Step Next Step dvantage Body pplication TB TBX PPS In-line, twist-lock, submersion TB6 TBX6 PVD In-line, threaded, submersion TB7 TBX7 PVD Ball valve retractor, hot-tap TB6 TBX6 PVD In-line, sterilizable TB6 TBX6 PVD High pressure retractor, hot-tap TB67 TBX67 PPS In-line, high pressure To promote TB(X) electrode process efficiency, reference junctions are available as either wood or PTE, each also offered in flush or notched forms. The hardwood junction is recommended for all general purpose duties particularly those requiring high resistance to coating. PTE junctions are promoted for continuous processes over. ph or those containing known wood delignifiers such as strong caustics, bleaches and other oxidizers. lush junctions have no process protrusions and therefore supply excellent self-cleaning properties when used with flat glass and fitted at 9 in process pipelines. Notched junctions provide an integral protection guard for normal bulb-style glasses and are especially suited for retractable and immersion sensors. ph Type flat glass ph Type general purpose glass Type high temperature glass Type f fluoride / acid resistant glass Type j coating resistant glass Normal glass lat glass lush Notched Junction styles ORP Type platinum Type gold Electrode types Sensor models and applications Junction styles Style Description pplication lush lush with end of sensor In-line, heavy fouling processes Notched Extends beyond junction providing electrode protection Hot-tap (ball valve) and immersion sensors Reference junction selection Sensor TB(X) lush Notched Wood PTE Electrodes Wood PTE Electrodes,,,,,, J 6,,,,,, J,,,,,, J 7,,,,,, J 6,,,,,, J,,,,,, J 6,,,,,, J,,,,,, J 67,,,,, J Note. = Valid selection = Invalid selection

5 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H Temperature compensation Temperature compensators enable analyzers to adjust for temperature effects on the glass ph electrode output (Nernst). Selected analyzers can also use this measurement to compensate for solution ph temperature effects. Sensors can be ordered with integral temperature sensors or as external units. The integral temperature compensator is available in two forms; Balco k and Pt. Temperature compensator location (typical) Cable options TB(X) sensors offer complete flexibility of cabling options throughout the range. ll cables are potted inside the sensor ensuring environmental protection. The standard cable length for most sensors is. m ( ft.). However, cables can be supplied as any continuous size up to 9 m ( ft.). Standard accessories include junction boxes and submersion (immersion) couplers, typically used with extension cables for direct connection to BB-TBI instruments. Extension cables also permit distances between sensor and instrument of up to m ( ft.) without external preamplifier. Integral temperature compensator ph error Temperature change ( C) + from C + + BNC / TC to pin terminal adapter is available for connection to TB8, TB8, 6 and X6 series instruments. Sensors with pin terminals are selected with code option T ph Error without temperature compensation Next Step dvantage sensor cables and junction box wiring (TBX sensors) ORP / Redox sensors without temperature compensator ph sensors with temperature compensator Pin leads (type 'T' cable) Pin leads (type 'T' cable) To junction box emale BNC and spade lugs for junction box (type 'O' cable) To TB8, TB8, 6 and X6 To junction box emale BNC and spade lugs for junction box (type 'O' cable) To TB8, TB8, 6 and X6 Male BNC / spade lug to pin leads extension (cable TB -7XXX) Heavey green Green Black Male BNC / spade lug to pin leads extension (cable TB -7XXX) Heavey green Green White Red Black Junction box wiring (TB-88) Junction box wiring (TB-88)

6 6 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H Solid state and Next Step reference sensor cables and junction box wiring (TB models) ORP / Redox sensors without temperature compensator ph sensors with temperature compensator Male BNC (type '' cable) Male BNC and tinned temperature compensator leads (type '' cable) Pin leads (type 'T' cable) Male BNC and extension cable connector on temperature compensator leads (type '' cable) emale BNC to sensor or junction box Extension cable (cable TB-XXX) Male BNC Pin leads (type 'T' cable) To sensor or junction box To transmitter emale BNC to sensor or junction box Pin extension cable (cable TB-XXX) Pin leads to TB8, TB8 and X6 emale BNC to male BNC extension with temperature compensator connector to tinned leads (cable TB -XXX) To sensor or junction box Pin lead extension with temperature compensator connector (cable TB-XXX) Pin leads to TB8, TB8, 6 and X6 Junction box wiring (TB-6) emale BNC to pin leads adaptor (TB9-6) Temperature compensator extension cable connector to pin leads adaptor (TB9-77) Note. Junction box not supplied with cable gland kit (part number: TB9-)

7 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H 7 TB and TBX Ryton sensors TB(X) sensors are in-line flow-through or submersible (immersion), general purpose, twist-lock style sensors. The sensor body is molded from chemically resistant Ryton (PPS). The sensor can be adapted to in. fittings by either a threaded Ryton receptacle or a twist-lock receptacle. The twist-lock receptacle is available in Kynar (PVD) or stainless steel. Optional electrode guards protect the electrode in submersion (immersion) applications. Specification pplications In-line, flow-through, submersible (immersion) Maximum pressure / temperature 69 kpa ( psi) at C (8 ) eatures Low cost, universal type. dapter for twist-lock, or threaded-cap, insertion Material Body Junction Junction types Ryton (polyphenylene sulphide) Wood or PTE lush TB(X) Ryton sensors Overall dimensions TB(X) Dimensions in mm (in.) lex conduit and coupling (customer-supplied) / in. NPT Ryton body Safety catch assembly 67 (6.7) No. 8 Viton O-rings each Sensor in. NPT tee (customer-supplied) low Ryton-threaded receptacle Twist-lock receptacle 6 stainless steel Kynar. (.) PVC submersible guard 9. (.7) 67 (6,7) 6. (.) 7. (.8) / in. NPT Electrode (.7).. (.) (.7) / in. NPT 6. conduit port (.) ( typical) 76.9 (.9) Sensor with junction box 6.7 (.). (.96)

8 8 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H Ordering information TB Standard solid-state sensors no solution ground rod Next Step in-line, twist-lock, immersion (submersible) Ryton body ph / ORP sensor assembly (69 kpa [ psi] at C [8 ]) Measuring electrode lat glass ( to C, to ph) for high particulates with flow at 9 Glass, ph ( to C, to ph) High temperature glass ( to C, to ph) Platinum, Redox (ORP) Gold, Redox (ORP) Glass, ph, fluoride-resistant ( to 8 C, to ph) Coat-resistant glass / high temperature ( to C, to ph) Integral thermocompensation None kω Tinned leads kω Extension cable connector Pt Tinned leads, Pt Extension cable connector, Liquid junction Wood, flush PTE, flush PTE, recessed Wood, flush, Next Step reference PTE, flush, Next Step reference Solution ground rod material O-ring material Body style Ryton body ccessory hardware None Stainless steel, twist-lock receptacle (TB-8) Kynar (PVD), twist-lock receptacle (TB-9) PVC, submersible guard (TB-) Ryton (PPS), threaded receptacle (TB9-) Units of measure, integral sensor cable BNC connector, feet Tinned / Pin leads, feet Use when JB (below) is selected 6, 7 Length, integral sensor cable TB ft. (. m) ft. (8.8 m) enter length (in ft. increments) (available in increments of in. (.7 cm) to in. (76. cm). With junction box 6, 7 Less junction box 6, 7 X X X X X X X X J N/ N/ B 6 T J B J S Notes. or direct connection to P9, TB8, TB8, 6 / and X6 transmitters or other supplier devices, using terminal blocks. Not available for Redox (ORP) electrodes (codes & ). Not available for fluoride-resistant electrodes (code ). Compatible with P9, TB8, TB8, 6 / and X6 instruments. Kalrez O-rings only for solution ground sleeve. External O-rings are Viton. There are two options to connect to a transmitter using terminal blocks: Option use BNC / TC to PIN adapter with conduit fitting or BNC / TC to PIN adapter. In either case temperature compensator code must be or. Option select T in integral cable code, not designed for use with extension cables or junction box. 6 TB: junction box mounted on sensor. Cable length approximately mm ( in.). Requires extension cable. 7 TB(X): when selecting JB or JS, cable length is approximately mm ( in.). Requires extension cable. If junction box is ordered separately and longer cable lengths are required, enter length under code for integral cable.

9 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H 9 Ordering information TBX Sensors for self-checking with solution ground rod TBX Next Step dvantage, in-line, twist-lock, submersible (immersion) Ryton body ph / ORP sensor assembly (69 kpa [ psi] at C [8 ]) Measuring electrode lat glass ( to C, to ph) for high particulates with flow at 9 Glass, ph ( to C, to ph) High temperature glass ( to C, to ph) Platinum, Redox (ORP) Gold, Redox (ORP) Glass, ph, fluoride-resistant ( to 8 C, to ph) Coat-resistant glass / high temperature ( to C, to ph) Integral thermocompensation None kω Tinned leads Pt Tinned leads, Liquid junction Wood, flush PTE, flush Wood, flush, Next Step reference PTE, flush, Next Step reference Solution ground rod material 6 stainless steel Titanium Hastelloy B O-ring material Viton EPDM Silicone Kalrez Body style X X X X X X X X X X Ryton body ccessory hardware None Stainless steel, twist-lock receptacle (TB-8) Kynar (PVD), twist-lock receptacle (TB-9) PVC, submersible guard (TB-) Ryton (PPS), threaded receptacle (TB9-) Units of measure, integral sensor cable Tinned / Pin leads, feet Use when JB (below) is selected 6, 7 Length, integral sensor cable ft. (.m) ft. (8.8 m) enter length (in ft. increments) (available in increments of in. (.7 cm) to in. (76. cm). With junction box 6, 7 Less junction box 6, 7 J B 6 T J B J S Notes. or direct connection to P9, TB8, TB8, 6 / and X6 transmitters or other supplier devices, using terminal blocks. Not available for Redox (ORP) electrodes (codes & ). Not available for fluoride-resistant electrodes (code ). Compatible with P9, TB8, TB8, 6 / and X6 instruments. Kalrez O-rings only for solution ground sleeve. External O-rings are Viton. There are two options to connect to a transmitter using terminal blocks: Option use BNC / TC to PIN adapter with conduit fitting or BNC / TC to PIN adapter. In either case temperature compensator code must be or. Option select T in integral cable code, not designed for use with extension cables or junction box. 6 TB: junction box mounted on sensor. Cable length approximately mm ( in.). Requires extension cable. 7 TB(X): when selecting JB or JS, cable length is approximately mm ( in.). Requires extension cable. If junction box is ordered separately and longer cable lengths are required, enter length under code for integral cable.

10 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H TB6 & TBX6 Kynar sensors TB(X)6 sensors are threaded style sensors suitable for submersion (immersion) and insertion into the process pipes. Mounting thread size is / in. NPT. The sensor is available in several insertion lengths from the standard mm (. in.) to a maximum of 7 mm ( in.). The sensor body is molded from chemically resistant Kynar (PVD). Specification pplications / in. NPT process connection, in-line, submersion (immersion) Maximum pressure / temperature 69 kpa ( psi) at 8 C (76 ) 76 kpa ( psi) at C (8 ) Material Body Junction Junction types Kynar (PVD) as standard Wood or PTE lush Notched low-through Specify insertion depth in code Submersion / Immersion With notched junction TB(X)6 Kynar sensors Overall dimensions TB(X)6 Dimensions in mm (in.) Rear of sensor and cable to be sealed in conduit or pipe (customer-supplied) / in. NPT 7/8 in. Wrench flats 7. (.) / in. Coupling (customer-supplied) Sample outlet / in. Tee (customer-supplied) / in. NPT Kynar body Conduit (customer-supplied) Notched sensor Notched sensor Notched sensor submersible applications flow applications Sample inlet 9 (.7) 7. (.8) / in. NPT Electrode (,7) 8. (9.8). (.8) / in. NPT conduit port ( typical) Sensor with junction box 7.9 (.) minimum 8. (.) standard s specified up to 7. (.) maximum (see Note) Note. 7.9 mm (. in.) insertion depth not available on TBX dvantage sensors with solution grounds.

11 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H Ordering information TB6 Standard solid-state sensors no solution ground rod Next Step in-line, threaded, submersible (immersion), Kynar body ph / ORP sensor assembly (76 kpa [ psi] at C [8 ] / 69 kpa [ psi] at 9 C [9 ]) Measuring electrode lat glass ( to C, to ph) for high particulates with flow at 9 Glass, ph ( to C, to ph) High temperature glass ( to C, to ph) Platinum, Redox (ORP) Gold, Redox (ORP) Glass, ph, fluoride-resistant ( to 8 C, to ph) Coat-resistant glass / high temperature ( to C, to ph) Integral thermocompensation None kω Tinned leads kω Extension cable connector Pt Tinned leads, Pt Extension cable connector, Liquid junction Wood, flush PTE, flush Wood, notched PTE, notched Wood, flush, Next Step reference PTE, flush, Next Step reference Wood, notched, Next Step reference PTE, notched, Next Step reference Solution ground rod material O-ring material Body style Submersible (Immersion) probe.8 in. insertion depth. in. insertion depth. in. insertion depth. in. insertion depth. in. insertion depth. in. insertion depth. in. insertion depth. in. insertion depth. in. insertion depth. in. insertion depth Integral sensor cable 6 BNC connector, feet Tinned / Pin leads, feet 7 Use when JB (below) is selected 8, 9 Length, integral sensor cable ft. (. m) ft. (8.8 m) enter length (in ft. increments) With junction box 8, 9 Less junction box 8, 9 TB6 X X X X X X X X J N/ N/ 6 B D E 8 T J B J S Notes. Not available for Redox (ORP) electrodes (codes & ). Not available for fluoride-resistant electrodes (code ). Compatible with TB8, P9, TB8, 6 / and X6 instruments..8 in. insertion option not available with liquid junction options D & E.. in. insertion option not available with liquid junction options,,, B. Manufactured as. in.depth, includes cable strain relief. 6 There are two options to connect to a transmitter using terminal blocks: Option use BNC / TC to PIN adapter with conduit fitting or BNC / TC to PIN adapter. In either case temperature compensator code must be or. Option select T in integral cable code, not designed for use with extension cables or junction box. 7 or direct conection to type TB8, P9, TB8, 6 / and X6 transmitters, or other supplier devices, using terminal blocks. 8 TB6: junction box or submersible (immersion) connector mounted on sensor. Cable length approximately mm ( in.). Requires extension cable for temperature compensator code must be, or. 9 TB(X)6: junction box mounted on sensor. Cable length approximately mm ( in.). Requires extension cable for connection to transmitter. If junction box is ordered separately and longer cable lengths are required, enter cable length in code for integral cable.

12 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H Ordering information TBX6 Sensors for self-checking with solution ground rod TBX6 Next Step dvantage, in-line, threaded, submersible (immersion), Kynar body ph / ORP sensor assembly (76 kpa [ psi] at C [8 ] / 69 kpa [ psi] at 9 C [9 ]) Measuring electrode lat glass ( to C, to ph) for high particulates with flow at 9 Glass, ph ( to C, to ph) High temperature glass ( to C, to ph) Platinum, Redox (ORP) Gold, Redox (ORP) Glass, ph, fluoride-resistant ( to 8 C, to ph) Coat-resistant glass / high temperature ( to C, to ph) Integral thermocompensation None kω Tinned leads Pt Tinned leads, Liquid junction Wood, flush PTE, flush Wood, notched PTE, notched Wood, flush, Next Step reference PTE, flush, Next Step reference Wood, notched, Next Step reference PTE, notched, Next Step reference Solution ground rod material 6 stainless steel Titanium Hastelloy B O-ring material Viton EPDM Silicone Kalrez Body style Submersible (Immersion) probe. in. insertion depth. in. insertion depth. in. insertion depth. in. insertion depth. in. insertion depth. in. insertion depth. in. insertion depth. in. insertion depth Integral sensor cable 6 Tinned / Pin leads, feet 7 Use when JB (below) is selected 8, 9 Length, integral sensor cable ft. (. m) ft. (8.8 m) enter length (in ft. increments) With junction box 8, 9 Less junction box 8, 9 X X X X X X X X X J 6 B D E T J B J S Notes. Not available for Redox (ORP) electrodes (codes & ). Not available for fluoride-resistant electrodes (code ). Compatible with TB8, P9, TB8, 6 / and X6 instruments..8 in insertion option not available with liquid junction options D & E.. in insertion option not available with liquid junction options,,, B. Manufactured as. in.depth, includes cable strain relief. 6 There are two options to connect to a transmitter using terminal blocks: Option use BNC / TC to PIN adapter with conduit fitting or BNC / TC to PIN adapter. In either case temperature compensator code must be or. Option select T in integral cable code, not designed for use with extension cables or junction box. 7 or direct conection to type TB8, P9, TB8, 6 / and X6 transmitters, or other supplier devices, using terminal blocks. 8 TB6: junction box or submersible (immersion) connector mounted on sensor. Cable length approximately mm ( in.). Requires extension cable for temperature compensator code must be, or. 9 TB(X)6: junction box mounted on sensor. Cable length approximately mm ( in.). Requires extension cable for connection to transmitter. If junction box is ordered separately and longer cable lengths are required, enter cable length in code for integral cable.

13 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H TB7 and TBX7 hot-tap retractable sensors TB(X)7 sensors are hot-tap, ball valve insertion sensors. They enable sensor maintenance or replacement without interrupting the process. n integral safety anti-blowout lip is incorporated into the sensor design, preventing accidental sensor removal. Unlike chain restraints, this safety-by-design is an integral part of the sensors' construction. The sensor is inserted through a standard / in. or / in. full port ball valve which is sold seperately. Connection to a ball valve is by compression fitting available in either hand-tight with / in. NPT threads or wrench-tight with in. NPT threads. dditional fittings enable the assembly to be flushed and drained in situ and use a / in. NPT thread for connection to the ball valve. Specification pplications Insertion, hot-tap Maximum pressure / temperature 69 kpa ( psi) at 8 C (76 ) 76 kpa ( psi) at C (8 ) eatures Insert / retract without disturbing process flow Replaceable electrode nti-blowout lip No internal high-impedance connection Material Electrode Body Sensor sheath variants External O-rings Junction Junction types Lengths Kynar (PVD) as standard 6 stainless steel Hastelloy or Titanium Viton Wood or PTE lush (flat only) Notched Standard 6 mm (6 in.) Maximum mm (6 in.) TB7 and TBX7 sensors Overall dimensions Dimensions in mm (in.) Ball valve / or / in. ull port ball valve sold seperately Process line / vessel Compression fitting Compression fittings / in. diameter / in. hexagon / in. hexagon / in. NPT /8 in. hexagon in. NPT / in. NPT flushing port Wrench-tight compression fitting Hand-tight / in. NPT flushing port compression fitting / in. NPT 97.8 (.8) 66.7 (.6) 8.7 (7.7) 99. (7.8) Hand-tight Wrench-tight Wrench-tight flush and drain compression fitting / in. NPT Hand-tight flush and drain compression fitting

14 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H Overall dimensions Dimensions in mm (in.) TB(X)7 Kynar back piece Viton O-rings Sheath Replaceable sensor 6.7 (.) diameter.9 (.9) diameter 7.9 (.).9 (8.78) (other lengths available) 88 (7.). (.8) diameter No. 9 Viton O-rings Electrode Reference junction 9. (.7) / in. NPT 6 Stainless steel titanium or Hastelloy-C sheath Replacement sensor detail No 9 Viton O-rings Kynar body 7. (.8). (.7) / in. NPT conduit port ( typical). (.) diameter Kynar back piece nti-blowout lip Optional compression fitting hand-tight 6 stainless steel or titanium / in. NPT 97.8 (.8) / in. NPT full port ball valve Hand-tight compression fitting / in. NPT 6 stainless steel close nipple Sensor 7.9 (.) 66.7 (.6) Optional compression fitting wrench-tight 6 stainless steel, titanium or Hastelloy-C 6.7 (.) diameter / in. NPT in. NPT / in. NPT full port ball valve Reducing bushing / in. close nipple Sensor Wrench-tight compression fitting 8.6 (.) Installation detail

15 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H Ordering information TB7 Standard solid-state sensors no solution ground rod. Next Step ball valve insertion, hot-tap, TB7 Kynar body, ph / ORP sensor assembly (76 kpa [ psi] at C [8 ] / 69 kpa [ psi] at 9 C [9 ]) Measuring electrode lat glass ( to C, to ph) for high particulates with flow at 9 Glass, ph ( to C, to ph) High temperature glass ( to C, to ph) Platinum, Redox (ORP) Gold, Redox (ORP) Glass, ph, fluoride-resistant ( to 8 C, to ph) Coat-resistant glass / high temperature ( to C, to ph) Integral temperature compensator None (see page 7) kω Tinned leads kω Extension cable connector Pt Tinned leads, Pt Extension cable connector, Reference junction Wood, flush PTE, flush Wood, notched PTE, notched Wood, flush, Next Step reference PTE, flush, Next Step reference Wood, Notched, Next Step reference PTE, Notched, Next Step reference Solution ground rod material O-ring material Body style Replacement TB(X)7 electrode only 6 in. Titanium sheath 6 in. Hastelloy C sheath 6 in. 6 Stainless steel sheath in. Titanium sheath in. Titanium sheath in. Titanium sheath in. Hastelloy C sheath in. Hastelloy C sheath in. Hastelloy C sheath in. 6 Stainless steel sheath in. 6 Stainless steel sheath in. 6 Stainless steel sheath 6 in. Titanium sheath 6 in. 6 Stainless steel sheath ccessory hardware None 6 Stainless steel compression fitting, wrench-tight Hastelloy C compression fitting, wrench-tight 6 Stainless steel compression fitting, hand-tight Titanium compression fitting, hand-tight 6 Stainless steel compression fitting, wrench-tight with flush and drain assembly Titanium compression fitting, wrench-tight with flush and drain assembly Titanium compression fitting, wrench-tight 6 Stainless steel compression fitting, hand-tight with flush and drain assembly Titanium compression fitting, hand-tight with flush and drain assembly 6 Stainless steel compression fitting, wrench-tight with flush and drain assembly, EPDM O-rings 6 Stainless steel compression fitting, wrench-tight with flush and drain assembly, Kalrez O-rings Titanium compression fitting, wrench-tight with flush and drain assembly, EPDM O-rings Titanium compression fitting, wrench-tight with flush and drain assembly, Kalrez O-rings 6 Stainless steel compression fitting, hand-tight with flush and drain assembly, EPDM O-rings 6 Stainless steel compression fitting, hand-tight with flush and drain assembly, Kalrez O-rings Titanium compression fitting, hand-tight with flush and drain assembly, EPDM O-rings Titanium compression fitting, hand-tight with flush and drain assembly, Kalrez O-rings Integral sensor cable 6 BNC connector, feet Tinned / Pin leads, feet Use when JB or J to J6 (below) are selected 8, 9 Length, integral sensor cable ft. (. m) to 9 ft. (8.8 m) enter length (in ft. increments) With junction box Replacement sensor for 6 in.sheath Replacement sensor for in.sheath Replacement sensor for in.sheath Replacement sensor for in.sheath Replacement sensor for 6 in.sheath Replacement sensor for 6 in.sheath X X X X X X X X J N/ N/ 6 B D E 7 B G H J K L M N P R S B P T C D G H Q R U V T J B J J J J J J 6

16 6 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H Ordering information TBX7 Sensors for self-checking with solution ground rod Next Step DVNTGE, ball valve insertion, hot-tap, Kynar body, ph / ORP sensor assembly (76 kpa [ psi] at C [8 ] / 69 kpa [ psi] at 9 C [9 ]) Measuring electrode lat glass ( to C, to ph) for high particulates with flow at 9 Glass, ph ( to C, to ph) High temperature glass ( to C, to ph) Platinum, Redox (ORP) Gold, Redox (ORP) Glass, ph, fluoride-resistant ( to 8 C, to ph) Coat-resistant glass / high temperature ( to C, to ph) Integral temperature compensator None (see page 7) kω Tinned leads Pt Tinned leads, Reference junction Wood, flush PTE, flush Wood, notched PTE, notched Wood, flush, Next Step reference PTE, flush, Next Step reference Wood, Notched, Next Step reference PTE, Notched, Next Step reference Solution ground rod material 6 stainless steel Titanium Hastelloy B O-ring material Viton EPDM Silicone Kalrez Body style Replacement TB(X)7 electrode only 6 in. Titanium sheath 6 in. Hastelloy C sheath 6 in. 6 Stainless steel sheath in. Titanium sheath in. Titanium sheath in. Titanium sheath in. Hastelloy C sheath in. Hastelloy C sheath in. Hastelloy C sheath in. 6 Stainless steel sheath in. 6 Stainless steel sheath in. 6 Stainless steel sheath 6 in. Titanium sheath 6 in. 6 Stainless steel sheath ccessory hardware None 6 Stainless steel compression fitting, wrench-tight Hastelloy C compression fitting, wrench-tight 6 Stainless steel compression fitting, hand-tight Titanium compression fitting, hand-tight 6 Stainless steel compression fitting, wrench-tight with flush and drain assembly Titanium compression fitting, wrench-tight with flush and drain assembly Titanium compression fitting, wrench-tight 6 Stainless steel compression fitting, hand-tight with flush and drain assembly Titanium compression fitting, hand-tight with flush and drain assembly Integral sensor cable 6 Tinned / Pin leads, feet 7 Use when JB or J TO J6 (below) are selected 8, 9 Length, integral sensor cable ft. (. m) to 9 ft. (8.8 m) enter length (in ft. increments) With junction box Replacement sensor for 6 in.sheath Replacement sensor for in.sheath Replacement sensor for in.sheath Replacement sensor for in.sheath Replacement sensor for 6 in.sheath Replacement sensor for 6 in.sheath TBX7 X X X X X X X X X X J 6 B D E 7 B G H J K L M N P R S T J B J J J J J J 6

17 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H 7 Notes. Not available for Redox (ORP) electrodes (codes & ). Not available for fluoride-resistant electrodes (code ). Compatible with P9, TB8, TB8, 6 / and X6 instruments. lush junctions for flat electrodes only (code 6). Unless noted, standard hardware kits have Viton O-rings. Ball valve and process coupling sold separately. pplicable for all body styles. Mandatory for replacement sensors (code in Body Style section). 6 There are two options to connect to a transmitter using terminal blocks: Option use BNC / TC to PIN adapter with conduit fitting or BNC / TC to PIN adaptor. In either case temperature compensator code must be or. Option select T in integral sensor code, not designed for use with extension cables or junction box. 7 or direct connection to type P9, TB8, TB8, 6 / and X6 transmitters, or other supplier devices, using terminal blocks. 8 TB7: junction box mounted on sensor. Cable length varies to match body length style. Order code for body style and accessory hardware anything except zero. Requires extension cable. Order code for temperature compensator must be, or. 9 TB(X)7: junction box mounted on sensor. Cable length approximately mm ( in.). Order code for body style and accessory hardware anything except zero. Code # # # # # # #, J, B. Requires extension cable. If junction box is ordered separately and longer cable lengths are desired, enter cable length in integral sensor code. Standard cable length of ft. (. m) as measured from rear of sensor assembly with 6 in. sheath only. Maximum 9 ft. (8.8 m) cable only available with 6 in. sheath. Longer sheaths decrease length accordingly. pplicable to sensors with junction boxes only. Supplied with Integral sensor cable option and Integral temperature compensator options and only.

18 8 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H TB6 and TBX6 Sterilizable sensors TB(X)6 sensors are designed for sterilizable or in-line applications and for measurements in process vessels or lines requiring periodic sterilization or cleaning. They are also used in the TB8 Safe-T-Clean valve and TB9-9 stainless steel flow cell. The sensors are designed for use with a bushing and union nut but can also be retro-fitted into standard DN bushings with.98 in. to.99 in. internal diameters. ll hardware required for use with the TB8 Safe-T-Clean or TB9-9 flowcell is included with valve or flowcell when purchased. Specification pplications Batch processing with steam or chemical sterilization, fermenters, glass-lined reactors, pharmaceuticals, food and beverage Maximum pressure / temperature 69 kpa ( psi) at 9 C (76 ) 8 kpa (6 psi) at C ( ) 76 kpa ( psi) at C (8 ) Material Electrode body Junction Junction types Kynar (PVD) as standard Wood or PTE lush Notched Insertion depths 7,, or mm ( mm required for TB8 Safe-T-Clean valve and flowcell) TB6 and TBX6 sensors Overall dimensions TB(X)6 Dimensions in mm (in.) Notes.. Dashed lines represent dimensions of flow cell kit with Swagelock fittings.. low cell kit without Swagelock fittings tb9- flow cell kit with Swagelock fittings tb9-9 low cell (requires mm sensor) 98. (7.8) 66. (6.) 8. (.9) / in. NPT x / in. Swagelock fitting ( typical) Holder nut Kynar sensor body No. Viton O-ring ront view 8. (.). (6.) Order code 7:L = 7. (.76) Order code :L =. (.9) Order code :L =. (.9) Order code :L =. (7.87) L 8. (.) 7.9 (.8).9 (. / in. BSP Note. Customer-supplied holder nut slides over sensor and threads onto tank bushing Vessel wall Weld / in. BSP 8. (.) Tank bushing Safe-T-Clean sensor valve TB8 (requires mm sensor with flush liquid junction)

19 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H 9 Ordering information TB6 Standard solid-state sensors no solution ground rod Next Step sterilizable Kynar body ph / ORP sensor assembly (8 kpa [6 psi] at C [ ]) Measuring electrode lat glass ( to C, to ph) for high particulates with flow at 9 8 Glass, ph ( to C, to ph) High temperature glass ( to C, to ph) Platinum, Redox (ORP) Gold, Redox (ORP) Glass, ph, fluoride-resistant ( to 8 C, to ph) Coat-resistant glass / high temperature ( to C, to ph) Integral temperature compensator None kω Tinned leads kω Extension cable connector Pt Tinned leads, Pt Extension cable connector, Reference junction Wood, flush PTE, flush Wood, notched 7 PTE, notched 7 Wood, flush, Next Step reference PTE, flush, Next Step reference Wood, notched, Next Step reference 7 PTE, notched, Next Step reference 7 Solution ground rod material O-ring material Insertion depth 7 mm mm 9 mm mm Units of measure, integral sensor cable BNC connector, feet Tinned / Pin leads, feet Use when JB / JS (below) are selected 6, 7 Integral sensor cable ft. (. m) to ( ft) 8.8 m enter length (in ft. increments) With junction box 6, 7 Less junction box / submersible coupler 6, 7 TB6 X X X X X X X X X J N/ N/ 6 B D E 7 T J B J S Notes. or direct connection to type TB8, P9, TB8, 6 / and X6 transmitters or other supplier devices, using terminal blocks. Not available for Redox (ORP) electrodes (codes & ). Not available for fluoride resistant electrodes (code ). Compatible with TB8, TB8, P9, 6 / and X6 instruments. Insertion depth measured from wetted face of sensor flange to tip of guard. There are two options to connect to a transmitter using terminal blocks: Option use BNC / TC to PIN adapter with conduit fitting or BNC / TC to PIN adapter. In either case temperature compensator code must be or. Option select T in integral cable code, not designed for use with extension cables or junction box. 6 TB6: junction box mounted on sensor. Cable length approximately mm ( in.). Requires extension cable. If junction box is ordered separately and longer cable lengths are required enter length under code position for integral cable. 7 Not compatible with all TB8 Safe-T-Clean valve styles. 8 Required for use in most TB8 Safe-T-Clean valves. 9 Required for use with TB8 Safe-T-Clean valves and TB9-9 flowcell. Consult TB8 product specification sheet for comprehensive measuring electrode selection.

20 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H Ordering information TBX6 Sensors for self-checking with solution ground rod Next Step dvantage, sterilizable Kynar body ph / ORP sensor assembly (8 kpa [6 psi] at C [ ]) Measuring electrode lat glass ( to C, to ph) for high particulates with flow at 9 8 Glass, ph ( to C, to ph) High temperature glass ( to C, to ph) Platinum, Redox (ORP) Gold, Redox (ORP) Glass, ph, fluoride-resistant ( to 8 C, to ph) Coat-resistant glass / high temperature ( to C, to ph) Integral temperature compensator None kω Tinned leads Pt Tinned leads, Reference junction Wood, flush PTE, flush Wood, notched 7 PTE, notched 7 Wood, flush, Next Step reference PTE, flush, Next Step reference Wood, notched, Next Step reference 7 PTE, notched, Next Step reference 7 Solution ground rod material 6 stainless steel Titanium Hastelloy B O-ring material Viton EPDM Silicone Kalrez Insertion depth 7 mm mm 9 mm mm Units of measure, integral sensor cable Tinned / Pin leads, feet Use when JB / JS (below) are selected 6, 7 Length, integral sensor cable ft. (. m) ft. (8.8 m) enter length (in f.t increments) With junction box 6, 7 Less junction box 6, 7 TBX6 X X X X X X X X X X X J 6 B D E 7 T J B J S Notes. or direct connection to type TB8, P9, TB8, 6 / and X6 transmitters or other supplier devices, using terminal blocks. Not available for Redox (ORP) electrodes (codes & ). Not available for fluoride resistant electrodes (code ). Compatible with TB8, TB8, P9, 6 / and X6 instruments. Insertion depth measured from wetted face of sensor flange to tip of guard. There are two options to connect to a transmitter using terminal blocks: Option use BNC / TC to PIN adapter with conduit fitting or BNC / TC to PIN adapter. In either case temperature compensator code must be or. Option select T in integral cable code, not designed for use with extension cables or junction box. 6 TB6: junction box mounted on sensor. Cable length approximately mm ( in.). Requires extension cable. If junction box is ordered separately and longer cable lengths are required enter length under code position for integral cable. 7 Not compatible with all TB8 Safe-T-Clean valve styles. 8 Required for use in most TB8 Safe-T-Clean valves. 9 Required for use with TB8 Safe-T-Clean valves and TB9-9 flowcell. Consult TB8 Product Specification sheet for comprehensive measuring electrode selection.

21 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H TB6 and TBX6 high pressure hot-tap retractable sensors TB(X)6 are high pressure, hot-tap, ball valve, insertion sensors. They permit sensor maintenance or replacement without interrupting the process. or safety reasons, it is recommended that the operating pressure be reduced below 69 kpa ( psi) during insertion and retraction of the sensor assembly. Specification pplications High pressure, hazardous materials Maximum pressure / temperature 6 kpa ( psi) at C (8 ) eatures Insert / retract without complete process shutdown* Retraction housing for safety Taps for flushing or pressurizing Material Electrode body Ball-valve / hardware External O-rings Junction Junction types Kynar (PVD) 6 stainless steel Viton Wood or PTE lush Notched TB6 and TBX6 sensors * Safe operating pressure limits are recommended during retraction / insertion; maximum 69 kpa ( psi). Overall dimensions TB(X)6 Dimensions in mm (in.) Compression fitting with No. Viton O-ring / in. NPT / in. Elbow Compression fitting / in. 6 Stainless steel pipe plug ( typical) End cap Insertion assembly / in. tube, /8 in. wall Extraction housing Weld / in. 6 Stainless steel ball valve Reducing coupling guide Replacement Kynar sensor (.6) No. 7 Viton O-ring (.6) 8 (.) / in. NPT (.) /8 in. Wrench flats 9/6 in. Wrench flats (not shown) 68 (.6) (.) / in. NPT (.) 7 (6.8). (.7) 9. (.7) / in. NPT 7. (.8). (.7) / in. NPT conduit port ( typical) Interior O-ring No. Viton 6. (.) max. Note. ll pipe threads have Loctite PST sealant applied at the factory.

22 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H Ordering information TB6 Standard solid-state sensors no solution ground rod TB6 Next Step high pressure hot-tap ph / Redox (ORP) sensor assembly (6 kpa [psi] at C [8 ]) Measuring electrode lat glass ( to C, to ph) for high particulates with flow at 9 8 Glass, ph ( to C, to ph) High temperature glass ( to C, to ph) Platinum, Redox (ORP) Gold, Redox (ORP) Glass, ph, fluoride-resistant ( to 8 C, to ph) Coat-resistant glass / high temperature ( to C, to ph) Integral temperature compensator None kω Tinned leads kω Extension cable connector Pt Tinned leads, Pt Extension cable connector, Reference junction Wood, flush PTE, flush Wood, notched PTE, notched Wood, flush, Next Step reference PTE, flush, Next Step reference Wood, Notched, Next Step reference PTE, Notched, Next Step reference Solution ground rod material O-ring material Body style Standard, Kynar sensor body ccessory hardware Replacement sensor only Model TB(X)6 sensor assembly, with ball valve and coupling Model TB(X)6 sensor assembly, without ball valve and coupling Units of measure, integral sensor cable BNC connector, feet 7 Tinned / Pin leads, feet (recommended) Use when JB / JS (below) are selected 6 Integral sensor cable ft. (. m) to 9 ft. (8.8 m) enter length (in ft. increments) With junction box 6 Less junction box 6 X X X X X X X X J N/ N/ 6 B D E 9 T J B J S Notes. or direct connection to type TB8, P9, TB8, 6 / and X6 transmitters or other supplier devices using terminal blocks. Not available for Redox (ORP) electrodes (codes & ). Not available for fluoride-resistant electrodes (code ). Compatible with TB8, P9, TB8, 6 / and X6 instruments. Integral cable type T recommended, otherwise installation of BNC connector kit is required. There are two options to connect to a transmitter using terminal blocks: Option use BNC / TC to PIN adapter with conduit fitting or BNC / TC to PIN adapter. In either case temperature compensator code must be or. Option select T in sensor cable code, not designed for use with extension cables or junction box. 6 Junction box mounted on insertion rod. Cable length approximately mm ( in.). Requires extension cable to connect to transmitter. Order code for temperature compensator must be, or. If sensor is ordered without accessory hardware a junction box must be ordered separately. 7 Requires BNC field mount for replacement sensors. 8 Maximum pressure: 69 kpa ( psi).

23 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H Ordering information TBX6 Sensors for self-checking with solution ground rod Next Step dvantage, high pressure, hot-tap, ph / ORP sensor assembly (6 kpa [psi] at C [8 ]) Measuring electrode lat glass ( to C, to ph) for high particulates with flow at 9 8 Glass, ph ( to C, to ph) High temperature glass ( to C, to ph) Platinum, Redox (ORP) Gold, Redox (ORP) Glass, ph, fluoride-resistant ( to 8 C, to ph) Coat-resistant glass / high temperature ( to C, to ph) Integral temperature compensator None kω Tinned leads Pt Tinned leads, Reference junction Wood, flush PTE, flush Wood, notched PTE, notched Wood, flush, Next Step reference PTE, flush, Next Step reference Wood, Notched, Next Step reference PTE, Notched, Next Step reference Solution ground rod material 6 stainless steel Titanium Hastelloy B O-ring material Viton EPDM Silicone Kalrez Body style TBX6 X X X X X X X X X X Standard, Kynar sensor body ccessory hardware Replacement sensor only Model TB(X)6 sensor assembly, with ball valve and coupling Model TB(X)6 sensor assembly, without ball valve and coupling Units of measure, integral sensor cable 6 Tinned / Pin leads, feet (recommended) Use when JB / JS (below) are selected 6 Integral sensor cable ft. (. m) to 9 ft. (8.8 m) enter length (in ft. increments) With junction box 6 Less junction box 6 J 6 B D E 9 T J B J S Notes. or direct connection to type TB8, P9, TB8, 6 / and X6 transmitters or other supplier devices using terminal blocks. Not available for Redox (ORP) electrodes (codes & ). Not available for fluoride-resistant electrodes (code ). Compatible with TB8, P9, TB8, 6 / and X6 instruments. Integral cable type T recommended, otherwise installation of BNC connector kit is required. There are two options to connect to a transmitter using terminal blocks: Option use BNC / TC to PIN adapter with conduit fitting or BNC / TC to PIN adapter. In either case temperature compensator code must be or. Option select T in sensor cable code, not designed for use with extension cables or junction box. 6 Junction box mounted on insertion rod. Cable length approximately mm ( in.). Requires extension cable to connect to transmitter. Order code for temperature compensator must be, or. If sensor is ordered without accessory hardware a junction box must be ordered separately. 7 Requires BNC field mount for replacement sensors. 8 Maximum pressure: 69 kpa ( psi).

24 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H TB67 and TBX67 high pressure in-line sensors TB(X)67 sensors are high pressure, in-line sensors. Their permissible pressure and temperature ratings are unique in the industry. The assembly comprises two parts: a 6 stainless steel housing and a molded Ryton sensor body. or applications above 7 kpa ( psi), please consult BB. Specification pplications High pressure insertion Maximum pressure / temperature 8 kpa ( psi) at C (8 ) 7 kpa ( psi) at C ( ) eatures -piece sensor, double O-ring Sealed body with stainless steel sleeve Material Electrode body Outer sleeve External O-rings Junction Junction types Ryton (Polyphenylene sulphide) 6 stainless steel Viton Wood or PTE lush TB67 and TBX67 sensors Overall dimensions TB(X)67 Dimensions in mm (in.) Stainless steel sleeve No. 8 Viton O-rings ( typical) Ryton body Replaceable body 6.67 (.). (.9) 6. (6.) 6 Stainless in. NPT /6 in. Wrench flats steel body in. NPT ssembled sensor 8.6 (.) 9. (.7) 96.9 (7.7) 6. (.).7 (.) 7. (.8) Junction box Kynar adapter ssembled sensor Electrode (.7) / in. NPT conduit port ( typical) /6 in. Wrench flats / in. NPT in. NPT. (.9) 9. (.7)

25 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H Ordering information TB67 Standard solid-state sensors no solution ground rod TB67 Next Step in-line high-pressure ph / Redox (ORP) sensor assembly (8 kpa [ psi] at C [8 ]) Measuring electrode Glass, ph ( to C, to ph) High temperature glass ( to C, to ph) Platinum, Redox (ORP) Gold, Redox (ORP) Glass, ph, fluoride-resistant ( to 8 C, to ph) Coat-resistant glass / high temperature ( to C, to ph) Integral temperature compensator None kω Tinned leads kω Extension cable connector Pt Tinned leads, Pt Extension cable connector, Reference junction Wood, flush PTE, flush Wood, flush, Next Step reference PTE, flush, Next Step reference Solution ground rod material O-ring material Body style Model TB(X)67 sensor body ccessory hardware None Model TB(X)67 6 stainless steel sensor housing Units of measure, integral sensor cable BNC connector, feet Tinned / Pin leads, feet Use when JB / JS (below) are selected Integral sensor cable ft. (. m) to 9 ft. (8.8 m) enter length (in ft. increments) With junction box Less junction box X X X X X X X X J N/ N/ B 8 T J B J S Notes. or direct connection to type TB8, P9, TB8, 6 / and X6 transmitters or other supplier devices using terminal blocks. Not available for Redox (ORP) electrodes (codes & ). Not available for fluoride-resistant electrodes (code ). Compatible with TB8, TB8, 6 / and X6 instruments. There are two options to connect to a transmitter using terminal blocks: Option use BNC / TC to PIN adapter with conduit fitting or BNC / TC to PIN adapter. In either case temperature compensator code must be or. Option select T in sensor cable code, not designed for use with extension cables or junction box. Junction box mounted on sensor. Cable length approximately mm ( in.). Requires extension cable to connect to transmitter. Order code for temperature compensator must be, or. If sensor is ordered without accessory hardware a junction box must be ordered separately.

26 6 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H Ordering information TBX67 Sensors for self-checking with solution ground rod Next Step dvantage, in-line, high pressure, ph / ORP sensor assembly (8 kpa [ psi] at C [8 ]) Measuring electrode Glass, ph ( to C, to ph) High temperature glass ( to C, to ph) Platinum, Redox (ORP) Gold, Redox (ORP) Glass, ph, fluoride-resistant ( to 8 C, to ph) Coat-resistant glass / high temperature ( to C, to ph) Integral temperature compensator None kω Tinned leads Pt Tinned leads, Reference junction Wood, flush PTE, flush Wood, flush, Next Step reference PTE, flush, Next Step reference Solution ground rod material 6 stainless steel Titanium Hastelloy B O-ring material Viton EPDM Silicone Kalrez Body style TBX67 X X X X X X X X X X Standard, Kynar sensor body ccessory hardware None Model TB(X)67 6 stainless steel sensor housing Units of measure, integral sensor cable Tinned / Pin leads, feet Use when JB / JS (below) are selected Integral sensor cable ft. (. m) to 9 ft. (8.8 m) enter length (in ft. increments) With junction box Less junction box J B 8 T J B J S Notes. or direct connection to type TB8, P9, TB8, 6 / and X6 transmitters or other supplier devices using terminal blocks. Not available for Redox (ORP) electrodes (codes & ). Not available for fluoride-resistant electrodes (code ). Compatible with TB8, TB8, 6 / and X6 instruments. There are two options to connect to a transmitter using terminal blocks: Option use BNC / TC to PIN adapter with conduit fitting or BNC / TC to PIN adapter. In either case temperature compensator code must be or. Option select T in sensor cable code, not designed for use with extension cables or junction box. Junction box mounted on sensor. Cable length approximately mm ( in.). Requires extension cable to connect to transmitter. Order code for temperature compensator must be, or. If sensor is ordered without accessory hardware a junction box must be ordered separately.

27 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H 7 ccessories utomatic cleaners BB sensors are designed to resist fouling and plugging especially when placed in sufficient velocity. Sometimes a lack of velocity or the precipitative properties of the liquid require the use of an automatic cleaner. BB supplies jet-wash type cleaning facilities for submersion (immersion) TB6 sensors with / in. insertion depth. When coupled to a customer-supplied solenoid valve delivering wash fluid, effective cleaning can be initiated by BB ph instrumentation such as the TB8PH or X6 series. Specification Model TB- Materials PVC, Polypropylene 6 stainless steel Maximum pressure / temperature 69 kpa ( psi) at C ( ) 76 kpa ( psi) at 6 C ( ) or example, the TB8PH can be configured: wash cycle time to hours wash on time to 999 seconds wash recovery time to 999 seconds hold function ON or O Hydraulic cleaner with TB(X)6 sensor Hydraulic cleaner application example PCV or stainless steel / in. conduit (customer-supplied) Corrosion-resistant tubing (customer-supplied) PCV or stainless steel / in. coupling (customer-supplied) Cleaning solution ph sensor with an inserton depth of. in. / in. NPT / in. Union (customer-supplied) / in. 6 Stainless steel / in. Polypropylene Solenoid valve (customer-supplied) Configurable parameters include: Cycle time, On time, Recovery time Hold outputs Hydraulic cleaner housing (PVC) in. NPT threads Set screw to secure delivery tube

28 8 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H ccessories Ball valve kits for TB(X)7 sensors or use with compression fittings without flush and drain assemblies: Model Description TB-7 TB- TB-7 TB- TB-7 TB-8 / in. 6 stainless steel ball valve kit for use with in. wrench-tight compression fitting* / in. 6 stainless steel ball valve kit for use with in. wrench-tight compression fitting* / in. 6 stainless steel ball valve kit for use with / in. hand-tight compression fitting* / in. 6 stainless steel ball valve kit for use with / in. hand-tight compression fitting* / in. Kynar (PVD) ball valve kit for use with in. wrench-tight compression fitting* / in. Kynar (PVD) ball valve kit for use with / in. hand-tight compression fitting* *Kits include ball valve and appropriately sized process connector and reducing bushing. or use with compression fittings with flush and drain assemblies: Model TB-8 Description / in. 6 stainless steel ball valve with / in. process connector Miscellaneous Model Description TB9-6 TB9- TB9-77 emale BNC to pin leads adaptor Cable grip with reducer (/ in. to in) for use with junction box Temperature compensator extension cable connector to pin leads adaptor

29 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H 9 cknowledgements Hastelloy is a registered trademark of Haynes International Inc. Kalrez and Viton are registered trademarks of DuPont Dow Elastomers L.L.C. Kynar is a registered trademark of Elf tochem North merica Inc. LOCTITE is a registered trademark of Loctite Corporation Ryton is a registered trademark Chevron Phillips Chemical Company Swagelok is a copyright of Swagelok Company. ll rights reserved. Next Step and Next Step dvantage are trademarks of BB utomation Inc.

30 TBX PH, REDOX (ORP) SENSORS WITH DIGNOSTICS DS/TBX-EN REV. H Notes Sales Service

31

32 BB Limited Measurement & nalytics Oldends Lane Stonehouse Gloucestershire GL T UK Tel: + () ax: + () Mail: instrumentation@gb.abb.com BB Inc. Measurement & nalytics E. County Line Road Warminster P 897 US Tel: ax: abb.com/measurement We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. BB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. ny reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of BB. BB, 8 DS/TBX EN Rev. H 7.8

Combination ph/redox (ORP) Sensors

Combination ph/redox (ORP) Sensors Data Sheet Combination ph/redox (ORP) s Series AP00 User-customizable for Insertion, Flow-through, Immersion, Hot-tap Retractor ideal for Original Equipment Manufacturers and general applications Economical

More information

Combination ph/redox (ORP) Sensors

Combination ph/redox (ORP) Sensors Data Sheet SS/AP00_ Combination ph/redox (ORP) s AP00 Series User-customizable for Insertion, Flow-through, Immersion and Hot-tap Retractor ideal for OEMs (Original Equipment Manufacturers) and general

More information

AP300 Series Combination ph/redox (ORP) Sensors. Measurement made easy. A reliable economic solution for a wide range of applications

AP300 Series Combination ph/redox (ORP) Sensors. Measurement made easy. A reliable economic solution for a wide range of applications Data sheet DS/AP00 EN Rev. F AP00 Series Measurement made easy A reliable economic solution for a wide range of applications Long life large PTFE junction provides resistance to fouling double junction

More information

TBX5 ph, Redox (ORP) sensors With diagnostics. The most durable ph/redox (ORP) sensors in the world

TBX5 ph, Redox (ORP) sensors With diagnostics. The most durable ph/redox (ORP) sensors in the world Data sheet D/XEN Rev. X ph, Redox (ORP) sensors With diagnostics he most durable ph/redox (ORP) sensors in the world Next tep olid tate reference eliminates poisoning, pumping and plugging dvantage eries

More information

Analytical Instruments Two-Electrode Conductivity Sensors

Analytical Instruments Two-Electrode Conductivity Sensors Data Sheet Analytical Instruments Two-Electrode Conductivity Sensors Model TB2 Superior accuracy in low conductivity measurement ranges. Measurement ranges from 0 to 199.9 µs/cm to 0 to 19.99 ms/cm. Resolution

More information

TB(X)5 Series ph/redox (ORP) sensors for process monitoring

TB(X)5 Series ph/redox (ORP) sensors for process monitoring Data sheet D/XEN Rev. E (X) eries ph/redox (ORP) sensors for process monitoring he most durable ph/redox (ORP) sensors in the world Next tep olid tate reference eliminates poisoning, pumping and plugging

More information

Single and Dual Input Analyzers for ph/redox (ORP)

Single and Dual Input Analyzers for ph/redox (ORP) Data Sheet SS/AXPH Issue 7 Single and Dual Input Analyzers for ph/redox (ORP) AX, AX and AX Cost effective select one or two ph/redox (ORP) inputs or combine ph/redox (ORP) and conductivity in one analyzer

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. TB4CS 4-electrode conductivity sensor

ABB MEASUREMENT & ANALYTICS DATA SHEET. TB4CS 4-electrode conductivity sensor ABB MEASUREMENT & ANALYTICS DATA SHEET TBCS -electrode conductivity sensor TB CS -EL ECTRODE CON DUCTIV IT Y SE NSOR DS/ TBC S-E N RE V. I Measurement made easy Low maintenance sensor with the widest operation

More information

Accessories Guide ph/orp/conductivity Sensors

Accessories Guide ph/orp/conductivity Sensors Jet Cleaners and Scrubber Accessories Isolation Ball Valves Assemblies Compression Fittings and Sheath Sets High Pressure (2500 PSIG) Sensor Housings In-line Flow Cells Nut Lock Union Style Adapters Sensor

More information

Models 396/396P/396R. Retraction/Submersion/Insertion ph/orp Sensor

Models 396/396P/396R. Retraction/Submersion/Insertion ph/orp Sensor Models 396/396P/396R Product Data Sheet PDS 71-TUpH September 1999 Retraction/Submersion/Insertion ph/orp Sensor MINIMUM SENSOR MAINTENANCE due to patented TUpH reference technology 1 which ensures steady

More information

TB4CS Conductivity sensor 4-Electrode. Low maintenance sensor with the widest operation range available (0 to 2000 ms/cm)

TB4CS Conductivity sensor 4-Electrode. Low maintenance sensor with the widest operation range available (0 to 2000 ms/cm) Data sheet TB4CS Conductivity sensor 4-Electrode Low maintenance sensor with the widest operation range available (0 to 2000 ms/cm) 4-electrode measurement Increases accuracy, stability, flexibility, and

More information

Liquid Conductivity Two & Four Electrode Sensors

Liquid Conductivity Two & Four Electrode Sensors Industrial Process Control & Monitoring Rugged Two Electrode Conductivity Sensors Unique Four Electrode Conductivity Sensors Versatile Installation Options (Threaded, Quick Change, Retractable) Specialized

More information

Combination ph/redox (ORP) Sensors

Combination ph/redox (ORP) Sensors User Guide IM/AP300_6 Combination ph/redox (ORP) Sensors AP300 Series ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control,

More information

Performance Series ph/orp Sensors

Performance Series ph/orp Sensors Industrial Process Control & Monitoring Patented Axial Ion Path Reference Specialized ph Glass Formulations and ORP Electrodes Proprietary Low-Noise, High Temperature Signal Cable Sensors are Compatible

More information

NEW QUICK CABLE-TO-SENSOR RELEASE,

NEW QUICK CABLE-TO-SENSOR RELEASE, Models 399 and 399VP Product Data Sheet PDS 71-399 October 2000 ph/orp Sensors NEW OPTIONS to meet a variety of application requirements, including: * Low ionic strength water * Processes with hydrofluoric

More information

TUpH Retraction/Submersion/Insertion ph/orp Sensors

TUpH Retraction/Submersion/Insertion ph/orp Sensors Product Data Sheet PDS 71-TUpHVP/rev.B June 2003 Models 396VP, 396RVP, 398VP, & 398RVP TUpH Retraction/Submersion/Insertion ph/orp Sensors SILCORE 3 TECHNOLOGY PROVIDES INCREASED SENSOR LIFE when used

More information

Analytical Instruments Four-Electrode Conductivity Sensors for Process Monitoring Model TB4

Analytical Instruments Four-Electrode Conductivity Sensors for Process Monitoring Model TB4 Data Sheet Analytical Instruments Four-Electrode Conductivity Sensors for Process Monitoring Model TB4 Four-electrode measurement: Increases accuracy, stability, flexibility, and security Highest temperature

More information

Insertion/Submersion Flow Through Sensor

Insertion/Submersion Flow Through Sensor Product Data Sheet PDS 71-381/rev.B September 2004 Model 381 ph/orp Insertion/Submersion Flow Through Sensor ADVANCED ON-LINE SENSOR DIAGNOSTICS 1 (Model 381+ only), for use with the Models 54e ph/orp

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP200 Rugged ph/redox (ORP) sensor systems with rapid temperature response for critical processes

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP200 Rugged ph/redox (ORP) sensor systems with rapid temperature response for critical processes ABB MEASUREMENT & ANALYTICS DATA SHEET AP200 Rugged ph/redox (ORP) sensor systems with rapid temperature response for critical processes 2 AP200 RUGG ED P H / REDOX ( ORP ) SE NSOR SYSTE MS DS/AP200-E

More information

Rugged ph/redox (ORP) Sensor Systems with Rapid Temperature Response for Critical Processes

Rugged ph/redox (ORP) Sensor Systems with Rapid Temperature Response for Critical Processes Data Sheet SS/AP200 Issue 7 Rugged ph/redox (ORP) Sensor Systems with Rapid Temperature Response for Critical Processes AP200 Series! Safe operation and high process resistance PPS Ryton body operates

More information

General Purpose ph/orp Sensors

General Purpose ph/orp Sensors Product Data Sheet PDS 71-3900/rev. B December 2010 Models 3900 and 3900VP General Purpose ph/orp Sensors EXTENDED SENSOR LIFE provided by double junction reference. ENHANCED PERFORMANCE AND INCREASED

More information

General Purpose ph/orp Sensors

General Purpose ph/orp Sensors General Purpose ph/orp Sensors Product Data Sheet LIQ_PDS_3900 September 2013 General Purpose ph/orp Sensors SMART preamplifier-stores calibration and other data. Extended sensor life provided by double

More information

ph/orp Sensor Model 399 ph/orp

ph/orp Sensor Model 399 ph/orp Model 399 ph/orp Product Data Sheet PDS 71-399 September 1999 ph/orp Sensor DOUBLE JUNCTION REFERENCE CELL provides longer sensor life in process solutions containing poisoning ions. ONE-PIECE CONSTRUCTION

More information

Performance Series ph/orp Sensors

Performance Series ph/orp Sensors Industrial Process Control & Monitoring Patented Axial Ion Path TM Reference Specialized ph Glass Formulations and ORP Electrodes Proprietary Low-Noise, High Temperature Signal Cable Sensors are Compatible

More information

Signet DryLoc ph/orp Electrodes

Signet DryLoc ph/orp Electrodes Signet 2774-2777 DryLoc ph/orp Electrodes Features Patented DryLoc connector with gold plated contacts* Special design allows for installation at any angle, even inverted or horizontal Quick temperature

More information

Performance Series ph/orp Sensors

Performance Series ph/orp Sensors Industrial Process Control & Monitoring Patented Axial Ion Path TM Reference Specialized ph Glass Formulations and ORP Electrodes Proprietary Low-Noise, High Temperature Signal Cable Sensors are Compatible

More information

Signet 3719 ph/orp Wet-Tap

Signet 3719 ph/orp Wet-Tap Signet 3719 ph/orp Wet-Tap *3-3719.090* 3-3719.090 Rev H 09/07 English Do not exceed maximum temperature/pressure specifications. Wear safety goggles or face shield during installation/service. Do not

More information

AST10 & AST51 Contacting Conductivity Sensors

AST10 & AST51 Contacting Conductivity Sensors AST10 & AST51 Contacting Conductivity Sensors AST10 Contacting Conductivity Sensors in K=3.0/cm cell constant (without cap & without compression fitting) & K=10.0/cm cell constant with Hastelloy C-276

More information

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.J January 2011

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.J January 2011 Product Data Sheet PDS 71-400/rev.J January 2011 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Pre-determined cell constant ensures out-of-the

More information

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.I December 2008

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.I December 2008 Product Data Sheet PDS 71-400/rev.I December 2008 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Pre-determined cell constant ensures out-of-the

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. AC200 Series Industrial 2-electrode conductivity cells with rapid temperature response

ABB MEASUREMENT & ANALYTICS DATA SHEET. AC200 Series Industrial 2-electrode conductivity cells with rapid temperature response ABB MEASUREMENT & ANALYTICS DATA SHEET AC00 Series Industrial -electrode conductivity cells with rapid temperature response AC00 SE RIE S I N DUST RI AL -ELE C TRODE CONDU C TIV IT Y C E LLS DS/AC CO-E

More information

Signet DryLoc ph/orp Electrodes

Signet DryLoc ph/orp Electrodes Signet 2774-2777 DryLoc ph/orp Electrodes Features Patented DryLoc connector with gold plated contacts* Special design allows for installation at any angle, even inverted or horizontal Quick temperature

More information

Dissolved Oxygen, ph, and Conductivity

Dissolved Oxygen, ph, and Conductivity Product Data Sheet PDS 71-steam/rev.E February 2005 Steam Sterilizable Solutions Dissolved Oxygen, ph, and Conductivity STEAM STERILIZABLE AND AUTOCLAVABLE DISSOLVED OXY- GEN, ph, AND CONDUCTIVITY SENSORS:

More information

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013 Product Data Sheet PDS 71-400/rev.K February 2013 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Factory-measured cell constant ensures out-of-the-box

More information

Low Cost Submersion and In-Line ph Electrodes

Low Cost Submersion and In-Line ph Electrodes Low Cost Submersion and In-Line Electrodes Economical design for in-line or submersion use Choose from single or double models Threaded 1/2" or 3/4" NPT connections Choose from spherical or flat measuring

More information

Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines

Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines Technical Information Cleanfit CPA471 Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines Application Chemical industry Wastewater treatment Plant design Tanks and

More information

TUpH 396, 396VP, 396P, 396PVP, 396R, 396RVP

TUpH 396, 396VP, 396P, 396PVP, 396R, 396RVP TUpH 396, 396VP, 396P, 396PVP, 396R, 396RVP Product Data Sheet LIQ-PDS-396P-PVP-R-RVP April 2016 TUpH 396, 396VP, 396P, 396PVP, 396R, 396RVP Retraction/Submersion/Insertion ph/orp Sensors Smart enabled

More information

SIGNET 2760 DryLoc ph/orp Preamplifier

SIGNET 2760 DryLoc ph/orp Preamplifier SIGNET 2760 DryLoc ph/orp Preamplifier 3-2760.090 3-2760.090 (A-3/04) English SAFETY INSTRUCTIONS 1. Depressurize and vent system prior to installation or removal. 2. Confirm chemical compatibility before

More information

Cleanfit W CPA450. Technical Information. Retractable assembly for 12 mm sensors for DO/pH/ORP measurement

Cleanfit W CPA450. Technical Information. Retractable assembly for 12 mm sensors for DO/pH/ORP measurement Technical Information Cleanfit W CPA450 Retractable assembly for 12 mm sensors for DO/pH/ORP measurement Application Pulp and paper industry Chemical industry Measurement in fibrous or coating media Tanks

More information

871PH Series ph, ORP, and Fluoride Sensors and Accessories

871PH Series ph, ORP, and Fluoride Sensors and Accessories Product Specifications PSS 6-1C2 A 871PH Series ph, ORP, and Fluoride Sensors and Accessories 871PH multi-purpose precision electrochemical sensors, used in conjunction with 871PH accessories, are suitable

More information

Signet 2760 DryLoc ph/orp Preamplifier

Signet 2760 DryLoc ph/orp Preamplifier Signet 2760 DryLoc ph/orp Preamplifier *3-2760.090* 3-2760.090 Rev. H 05/11 English English SAFETY INSTRUCTIONS 1. Depressurize and vent system prior to installation or removal. 2. Confi rm chemical compatibility

More information

Signet ph/orp Electrodes

Signet ph/orp Electrodes Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Patented reference design for exceptional performance * Mounts in Signet standard fittings from DN15 to DN100 (½

More information

Encapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials)

Encapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials) Technology For Solutions Data Sheet LRE/102 Supersedes LRE/400 Encapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials) Common Features Differential Electrode

More information

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006 Product Data Sheet PDS 71-400/rev.G February 2006 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Pre-determined cell constant ensures out-of-the

More information

7777 Immersion/In-Line Mounting for Meredian II ph/orp Electrodes Installation and Maintenance Manual

7777 Immersion/In-Line Mounting for Meredian II ph/orp Electrodes Installation and Maintenance Manual 7777 Immersion/In-Line Mounting for Meredian II ph/orp Electrodes Installation and Maintenance Manual 70-82-25-05 Rev. 1 3/08 Honeywell Process Solutions Copyright, Notices, and Trademarks Printed in U.S.A.

More information

Signet ph/orp Electrodes

Signet ph/orp Electrodes Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Flat Glass Protected Bulb Patented reference design for exceptional performance * Mounts in Signet standard fittings

More information

For additional information, please visit our website at SENSOR SPECIFICATIONS

For additional information, please visit our website at  SENSOR SPECIFICATIONS Instruction Sheet PN 51A-140/rev.E December 2010 Models 140, 141, and 142 Conductivity Sensors For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. SENSOR/PROCESS

More information

Retractable ph/orp Sensors

Retractable ph/orp Sensors Model 396R and 396RVP Instruction Manual PN 5100396R January 2001 Retractable ph/orp Sensors ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING! Rosemount Analytical designs, manufactures, and tests

More information

* * Rev. 9 01/18 Product Manual

* * Rev. 9 01/18 Product Manual English Signet 2760 DryLoc ph/orp Preamplifier *3-2760.090* 3-2760.090 Rev. 9 01/18 Product Manual Description The Signet 2760 ph/orp Preamplifiers with DryLoc connectors are part of Signet's growing line

More information

General Specifications

General Specifications General Specifications Compact ph Probes Model EXA Series EXA Compact is a versatile series of probes suitable for ph measurements in all common applications in industrial processes and (waste) water treatment

More information

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions Technical Information Cleanfit H CPA475 Retractable assembly for ph, ORP measurement under sterile conditions Application Food industry Beverage industry Pharmaceutical industry Drinking water The retractable

More information

ph-kompaktelektrodensystem sensopac CPA 320

ph-kompaktelektrodensystem sensopac CPA 320 Technische Information TI 0C/0/de ph-kompaktelektrodensystem sensopac CPA 0 One of the two reference systems is specially protected so that only the second monitoring reference system is affected by penetration

More information

OPERATING INSTRUCTION MANUAL

OPERATING INSTRUCTION MANUAL OPERATING INSTRUCTION MANUAL MODEL P/R65 DIFFERENTIAL 2-WIRE (4-20 ma) ph & ORP PROBES N116-139 REV. 0 Aquametrix, by Water Analytics Inc. 100 School Street Andover, MA 01810 Tel: (978) 749-9949 Toll Free:

More information

Signet Conductivity/Resistivity Electrodes

Signet Conductivity/Resistivity Electrodes Signet 2818-2823 Conductivity/Resistivity Electrodes 2818 2819 2820 2821 2822 2823 Sanitary Features Standard process connections - Polypro - SS on 10 and 20 cell - Tri-clamp 1-1½ in., 2 - Opt. ½ in. NPT

More information

Signet ph/orp Electrodes

Signet ph/orp Electrodes Signet 2734-2736 ph/orp Electrodes Compatible with Signet 8900/9900 Instruments Features Patented reference design for exceptional performance * Mounts in Signet standard fittings from DN15 to DN100 (½

More information

Cleanfit P CPA472D. Technical Information. Retractable process assembly for ph, ORP and other industry sensors Heavy-duty version

Cleanfit P CPA472D. Technical Information. Retractable process assembly for ph, ORP and other industry sensors Heavy-duty version Technical Information Cleanfit P CPA472D Retractable process assembly for ph, ORP and other industry sensors Heavy-duty version Application Chemical industry Power plants Plant design Tanks and process

More information

SIGNET 3719 ph/orp Wet-Tap

SIGNET 3719 ph/orp Wet-Tap ENGLISH 3-3719.090 B-6/02 English Do not exceed maximum temperature/pressure specifications. Wear safety goggles or face shield during installation/service. Do not attempt to disassemble the retraction

More information

Signet 3719 ph/orp Wet-Tap Assembly

Signet 3719 ph/orp Wet-Tap Assembly Signet 3719 ph/p Wet-Tap Assembly Features Electrode removal without process shutdown Space saving 45 mm (1.75 in.) short-stroke design Sealed pneumatic dampening for smooth and safe operation SafeLoc

More information

Signet Conductivity/Resistivity Electrodes

Signet Conductivity/Resistivity Electrodes Signet 2818-2823 Conductivity/Resistivity Electrodes 2818 2819 2820 2821 2822 2823 Sanitary Features Standard process connections - Polypro - SS on 10 and 20 cell - Tri-clamp 1-1½ in., 2 in. - Opt. ½ in.

More information

General Specifications

General Specifications General Specifications Model PH20 and FU20 ph/redox and Temperature sensor The PH20 is nicknamed "Tempress" because of the patented compensation for changes in the process temperature and pressure. This

More information

Automatic sensor lock-gate for extreme applications with ceramic sealing to the proces

Automatic sensor lock-gate for extreme applications with ceramic sealing to the proces Pneumatic Retractable Fittings Chem Energy Pharm Food Water Ceramat Sensor Lock-Gate Automatic sensor lock-gate for extreme applications with ceramic sealing to the proces Unique lock-gate principle The

More information

Signet 515 Rotor-X Paddlewheel Flow Sensors

Signet 515 Rotor-X Paddlewheel Flow Sensors Signet 515 Rotor-X Paddlewheel Flow Sensors Features Operating range 0.3 to 6 m/s (1 to 20 ft/s) Wide turndown ratio of 20:1 Highly repeatable output Simple, economical design Installs into pipe sizes

More information

Technical Information Cleanfit CPA472D

Technical Information Cleanfit CPA472D TI00403C/07/EN/13.13 71227170 Products Solutions Services Technical Information Cleanfit CPA472D Retractable process assembly for ph and ORP sensors Heavy duty version Application Chemical industry Biodiesel

More information

Instruction. MI September PH12 Series ph and ORP Sensors and Accessories Installation, Troubleshooting, and Maintenance

Instruction. MI September PH12 Series ph and ORP Sensors and Accessories Installation, Troubleshooting, and Maintenance Instruction MI 611-214 September 2012 PH12 Series ph and ORP Sensors and Accessories Installation, Troubleshooting, and Maintenance MI 611-214 September 2012 Contents Figures... Tables... v vii 1. Introduction...

More information

ISTEC MAGNETIC METERS

ISTEC MAGNETIC METERS ISTEC MAGNETIC METERS MEASURE ANY CONDUCTIVE LIQUIDS OR SLURRIES (EVEN ABRASIVE OR CORROSIVE) WITH THE NEW MICROPROCESSOR-BASED MAGNETIC METER -- A QUALITY PRODUCT - SIMPLE - RELIABLE - AT AN AFFORDABLE

More information

Rosemount 402 and 402VP

Rosemount 402 and 402VP Rosemount 402 and 402VP Contacting Conductivity Sensors Instruction Manual LIQ-MAN-402 Rev. M May 2017 hasgkas Essential Instructions Read this page before proceeding! Emerson designs, manufactures and

More information

AP200 series Rugged ph/redox (ORP) sensor systems with rapid temperature response for critical processes

AP200 series Rugged ph/redox (ORP) sensor systems with rapid temperature response for critical processes ABB MEASUREMENT & ANALYTICS USER GUIDE IM/AP00 REV. S Rugged ph/redox (ORP) sensor systems with rapid temperature response for critical processes Measurement made easy Rugged ph/redox (ORP) sensor systems

More information

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering Data Sheet 22943 Page 1/9 JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering Brief description The sensor detects the electrolytic conductivity of a process liquid.

More information

Inline version with application-specific process adaptation

Inline version with application-specific process adaptation Pneumatic Retractable Fittings hem Energy Pharm Food Water eramat WA 50 Inline version with application-specific process adaptation Facts for extreme applications ceramic sealing to the process: extremely

More information

Retractable ph/orp Sensors

Retractable ph/orp Sensors Instruction Manual PN 51-396R/rev.J February 2011 Model 396R and 396RVP Retractable ph/orp Sensors ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING! Rosemount Analytical designs, manufactures, and

More information

General Specifications

General Specifications General Specifications Model -FTS Differential ph/orp-sensor Overview The -FTS is the newest development in ph sensor technology available from Yokogawa. This sensor combines the measuring technology of

More information

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering Data Sheet 22943 Page 1/9 JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering Brief description The sensor detects the electrolytic conductivity of a process liquid.

More information

Signet 515 Rotor-X Paddlewheel Flow Sensors

Signet 515 Rotor-X Paddlewheel Flow Sensors Signet 515 Rotor-X Paddlewheel Flow Sensors Features Operating range 0.3 to 6 m/s (1 to 20 ft/s) Wide turndown ratio of 20:1 Highly repeatable output Simple, economical design Installs into pipe sizes

More information

Orbisint CPS12/CPS12D/CPS13

Orbisint CPS12/CPS12D/CPS13 Technical Information Orbisint CPS12/CPS12D/CPS13 ORP electrodes, analog and digital with Memosens technology and reference electrode Each with dirt-repellent PTFE diaphragm for standard applications in

More information

PN October Liquid Division. Mounting Solutions

PN October Liquid Division. Mounting Solutions PN 91-6020 October 2001 Liquid Division Mounting Solutions INTRODUCTION: Rosemount Analytical, Inc, Uniloc Division is pleased to offer a variety of sensor mounting options to fit many demanding process

More information

ENDURANCE Conductivity Sensors

ENDURANCE Conductivity Sensors Model 400 Series Instruction Manual P/N 5100400 May 1999 ENDURANCE Conductivity Sensors Model 400 Model 401 Model 402 Model 403 Model 404 Screw-in/Insertion Sensors Screw-in/Insertion Sensors Retractable

More information

Orbipore CPS91 and CPS91D

Orbipore CPS91 and CPS91D Technical Information Orbipore CPS91 and CPS91D ph electrodes, analog or with digital Memosens technology With open aperture for heavily soiled media, optional built-in temperature sensor Application Chemical

More information

Conductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.b February 2011

Conductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.b February 2011 Product Data Sheet 71-140 series/rev.b February 2011 Model 140, 141, 142 Conductivity Sensors RUGGED CONSTRUCTION withstands high temperature and pressure TWO MOUNTING CONFIGURATIONS: screw-in and retractable

More information

Retractable ph/orp Sensors

Retractable ph/orp Sensors Instruction Manual PN 51-398R/rev.G January 2011 Model 398R & 398RVP Retractable ph/orp Sensors MODEL 398R MODEL 398RVP (shown in ball valve) ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING! Rosemount

More information

FIELD DEVICES ANALYTICAL

FIELD DEVICES ANALYTICAL FIELD DEVICES ANALYTICAL Product Specifications DolpHin Series Models PH10 and ORP10 Analog and Smart Electrochemical Sensors and Accessories for ph and ORP Measurements PH10 and ORP10 Analog Versions

More information

UniMag DT Series Electromagnetic Flow Tubes

UniMag DT Series Electromagnetic Flow Tubes Description Spirax Sarco s UniMag DT Magnetic Flow Meter System consists of the patented UniMag Flow Tube and EFT10 Flow Transmitter. UniMag sensors are unique because they do not require a liner and can

More information

Probe holders for analytical probes

Probe holders for analytical probes Probe holders for analytical probes For many different types of installations and applications Large range of probe holders General purpose, water treatment, food & beverage, pharmaceutical applications

More information

ph (ORP) SENSOR ASSEMBLY

ph (ORP) SENSOR ASSEMBLY Specifications Sheet No.SPEC-3109E (3rd Edition) SP ph (ORP) SENSOR ASSEMBLY SPECIFICATIONS Flow-Through Type Probe Electrode holder for pipe line or sampling method Model SP3101 SP3111 Process connection

More information

Article on Sheath materials, Thermowells, Fittings, and Terminations

Article on Sheath materials, Thermowells, Fittings, and Terminations Article on Sheath materials, Thermowells, Fittings, and Terminations 1. INTRODUCTION Temperature sensor element for laboratory and industrial use should normally be protected by some form of sheath or

More information

Model Q45H/ Residual Chlorine Monitor...

Model Q45H/ Residual Chlorine Monitor... Model Q45H/62-63 Residual Chlorine Monitor... ATI s Model Q45H is designed for on-line monitoring and control of chlorination systems. It is available in two versions: a free chlorine monitor for drinking

More information

Low Cost Submersion and In-Line ph Electrodes

Low Cost Submersion and In-Line ph Electrodes Low Cost Submersion and In-Line Electrodes Economical design for in-line or submersion use Choose from single or double models Threaded 1/2" or 3/4" NPT connections Choose from spherical or flat measuring

More information

PN /rev. B April Liquid Division. Mounting Solutions

PN /rev. B April Liquid Division. Mounting Solutions PN 91-6020/rev. B April 2006 Liquid Division Mounting Solutions INTRODUCTION: Rosemount Analytical, Inc, Liquid Division is pleased to offer a variety of sensor mounting options to fit many demanding process

More information

Cable thermocouple Model TC40

Cable thermocouple Model TC40 Electrical temperature measurement Cable thermocouple Model TC40 WIKA data sheet TE 65.40 for further approvals see page 11 Applications For direct installation into the process Machine building Motors

More information

VRF II Series SURPASSING SENSITIVITY FOR THE TOUGHEST APPLICATIONS FEATURES AND BENEFITS STANDARD VS. ADVANCED UNITS

VRF II Series SURPASSING SENSITIVITY FOR THE TOUGHEST APPLICATIONS FEATURES AND BENEFITS STANDARD VS. ADVANCED UNITS VRF II Series SURPASSING SENSITIVITY FOR THE TOUGHEST APPLICATIONS The VRF II Series uses radio frequency to detect the presence or absence of material in a vessel. It compensates for the load of the probe

More information

Signet 2536 Rotor-X Paddlewheel Flow Sensors

Signet 2536 Rotor-X Paddlewheel Flow Sensors Signet 2536 Rotor-X Paddlewheel Flow s Features Operating range 0.1 to 6 m/s (0.3 to 20 ft/s) Wide turndown ratio of 66:1 Open-collector output Highly repeatable output Simple, economical design PVC (gray

More information

Conductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.a June 1998

Conductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.a June 1998 Product Data Sheet 71-140 series/rev.a June 1998 Model 140, 141, 142 Conductivity Sensors HIGH TEMPERATURE 316 SS AND PEEK CON- STRUCTION operates up to 200 C (392 F). MODEL 140 RETRACTABLE SENSOR installs

More information

S Series PACER Pumps. PACER Pumps 5/91 Page 1 of 5. Dultmeier Sales for Omaha, NE or for Davenport, IA

S Series PACER Pumps. PACER Pumps 5/91 Page 1 of 5. Dultmeier Sales for Omaha, NE or for Davenport, IA PACER Pumps 5/91 Page 1 of 5 Item# Part No. Description Qty. 4 58-0721 NUT, BODY, Plated steel, 1/4-20 Hex... 10 58-0721 10 NUT, BODY, Stainless steel, 1/4-20 Hex... 10 6 58-0703 30 Bracket, polyester...

More information

Valves. External Valves, Gages and Fittings. Bulletin No What options are available when stainless steel is not suitable for external parts.

Valves. External Valves, Gages and Fittings. Bulletin No What options are available when stainless steel is not suitable for external parts. External Valves, Gages and Fittings Bulletin No. 218 What options are available when stainless steel is not suitable for external parts. Unless otherwise specified, the external valves, gages, fittings

More information

Model 7777DVP Immersion/In-Line Mounting for Durafet III ph Electrodes Installation and Maintenance Rev. 1 3/04

Model 7777DVP Immersion/In-Line Mounting for Durafet III ph Electrodes Installation and Maintenance Rev. 1 3/04 Model 7777DVP Immersion/In-Line Mounting for Durafet III ph Electrodes 70-82-25-116 Rev. 1 3/04 Industrial Measurement and Control Copyright, Notices, and Trademarks Printed in U.S.A. Copyright 2004 by

More information

871DO-C Dissolved Oxygen Sensors and Sensor Accessories

871DO-C Dissolved Oxygen Sensors and Sensor Accessories Product Specifications PSS 6-9B1 A 871DO-C Dissolved Oxygen Sensors and Sensor Accessories 871DO-C REPLACEMENT MEMBRANE CAP ASSEMBLY The 871DO-C Sensor, when used in conjunction with 871DO-C Sensor Accessories

More information

Automatic sensor lock-gate for extreme applications with ceramic sealing to the proces

Automatic sensor lock-gate for extreme applications with ceramic sealing to the proces Pneumatic Retractable Fittings Chem Energy Pharm Food Water Ceramat Sensor Lock-Gate Automatic sensor lock-gate for extreme applications with ceramic sealing to the proces Unique lock-gate principle The

More information

Measurement and Instrumentation

Measurement and Instrumentation 15 Measurement and Instrumentation Use the postcard included in this handbook or call (800) 854-4090 to order the complete Instrumentation Catalog or visit www.gfsignet.com for detailed product information.

More information

Chapter Page. 1 Introduction Description 1

Chapter Page. 1 Introduction Description 1 Chapter Page 1 Introduction 1 1.1 Description 1 Table of Contents 2 Calibration 3 2.1 Wet Calibration 3 2.2 Calibration Procedure 4 2.3 Installing Optional Display Board 5 2.4 Display Board Range Adjustment

More information

General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)...

General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)... Page General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s High Temperature MgO Elements (RA).... Leadwire Style RTD s (RB).. Leadwire Style RTD s (RD, RE, RF, or RG

More information

DIN Hygienic Union & Fittings

DIN Hygienic Union & Fittings DIN 11851 Hygienic Union & 11852 Fittings The DIN 11851 union is widely used throughout Europe and the Middle East and incorporates a round slotted nut and D Section seal, as standard. The union is manufactured

More information