1 ndustrial Product Catalog Utility Small Submersible Specialty Magnetic Drive Wastewater Water Systems HVAC Industrial Engineered Products
2 hat's Hot! Hard-Working Pumps for Commercial, Industrial and Home Water Displays Fountains Air Conditioners Machine Tool Cooling More! Portable Utility Pump Our most versatile pump Oil-filled motor; epoxy-coated cast aluminum housing Screened inlet;.' maximum lift; pumps down to /" For submersible use only Series See page for more information. Small Submersible Pump Epoxy-coated cast aluminum housing Oil-filled motor Pumps gallons per hour (GPH) Screened inlet; 7.' maximum lift; thermal overload protection on most See page for more information. Series Small Submersible Nylon Pump Corrosion-resistant nylon housing Oil-filled motor GPH capacity Screened inlet;.' maximum lift; thermal overload protection See page for more information. NK- Series See your distributor for more information, or call Franklin Electric directly at
3 Industrial Product Catalog Utility Small Submersible Specialty Magnetic Drive Table of Contents Utility Pumps Pony Pump Series Replacement Impellers & Brush Kits B- Series... BPLA Series... UPSP Series.... Series... Small Submersible Pumps Epoxy Encapsulated, Direct Drive -EA Series PE- Series PE- Series PE-.F Series.... Oil-filled, Direct Drive P-AAA Series...9 -A Series...9 -MA Series.... -A Series... - Series Series... E-N Series... E-N Series... E-N Series... E-N Series... E-NR Series... E-NRY Series Small Submersible Pumps continued E-R Series E-N Series... E-NR Series... NK- Series... NK- Series...7 S Series Specialty Pumps Machine Tool Coolant Open Motor Pumps High Pressure Pumps... Parts Washer Pumps Acid Pumps... Circulator Pumps Magnetic Drive Pumps Magnetic Drive Series... - SC Series... - HC Series... - CK Series... - Peristaltic Pumps Tube Pumps... Specification Charts Specification Charts Viton is a registered trademark of DuPont Performance Elastomers. Teflon is a registered trademark of E.I. du Pont de Nemours and Company. Kynar is a registered trademark of Arkema Inc. Franklin Electric Co., Inc. Little Giant is a registered trademark of Franklin Electric Co., Inc.
4 Utility Pumps Pony Pump Series / HP Non-Submersible Use, Self-Priming Commercial, industrial and home uses where liquid must be transferred Self priming for instant delivery or de-watering up to ' () Non-submersible stainless steel or plated brass pump body Rugged metallic handle for easy portability Capacity: Up to GPH ( LPH) Dual threaded intake and discharge with both /" (9 mm) male garden hose thread and /" FNPT (9. mm) Model K includes pump, hose, strainer and suction adapter Pump only models available with separate kit options Item # Model Volts Cord Material ' Plated Brass S K 7 7 VDC S VDC ' ' ' " leads. cm " leads. cm Stainless Steel Plated Brass Plated Brass, Viton Seal Plated Brass Stainless Steel Pony Pump Replacement Impeller & Brush Kits Item # Model Includes Kit Used On 7 HRK-S () Each Nitrile Impeller w/sst Insert, Nitrile Cover Gaskets () Each SST Cam, SST Cam Screws, SST Volute Cover, Cam Gasket () Each Volute Cover Screws All Models 7 IRK- () Each Nitrile Impellers w/brass Insert, Nitrile Cover Gaskets,, 7 IRK-S () Each Nitrile Impellers w/sst Insert, Nitrile Cover Gaskets,, 7 ISRK-S () Each Nitrile Impellers w/sst Insert, Nitrile Cover Gaskets () Each Slinger/Viton U-Cup Seal/Felt Washer/Retainer Ring All Models 7 WB- Brush Kit: () Each White Caps/Brushes/Covers/Springs All Models For more information call..7.79
5 Utility Pumps B- SERIES / HP Submersible Use BPLA SERIES Submersible or In-line Use Commercial, industrial, and home uses where liquid must be transferred / HP oil-filled motor with overload protection Designed for continuous duty operation Epoxy coated, die-cast zinc body, impeller, housing, and filter stainless steel motor shaft Double lip Neoprene shaft seal Ball thrust bearing Garden hose threaded outlet UL listed Water removal from compact spaces such as boat bilges, recreational vehicles, or bait tanks VDC motor Submersible or in-line use Designed for intermittent use only Plastic and stainless steel construction Compact, light weight, operates in any position Port connections equipped with bilge inlet plate with strainer " MNPT (.7 mm) inlet plate accessory included Accepts /" ID (.9 mm) hose Capacity: ' ( Shut Off: ' ( m) Liquid Temperature: F (9 C) Discharge: /" GHT (9 mm) Intake: Screened Electrical: v, Hz Operation: Submersible only Capacity: ' ( m) Shut Off: ' (. m) Liquid Temperature: F (9 C) Discharge: /" MNPT (9. mm) Intake: Hooded or /" MNPT (.7 mm) Impeller: Nylon Electrical: VDC Operation: Submersible or in-line Item # Model Volts Cord B- ' Item # Model Volts Cord BPLA VDC ". mm For more information call..7.79
6 Utility Pumps UPSP SERIES / HP Non-Submersible, Self-Priming Flooded basements, watering lawns and draining water heaters Non-submersible, in-line, portable utility transfer pump with rugged one-piece cast iron housing and integral carrying handle Self-priming to ' (. m) when priming chamber is filled Can also be used to boost water pressure for washing vehicles, sidewalks and more Capacity: ' ( m) Shut Off: ' ( m) Liquid Temperature: F ( C) Discharge: /" FNPT (9 mm) Impeller: PPS Convenient /" (9 mm) brass garden hose adapters on intake and discharge UL / CSA listing Electrical: v, Hz Operation: In-line only 7 Item # Model Volts Cord Housing Mechanical Shaft Seal UPSP- ' m Cast Iron Volute Carbon / Ceramic For more information call..7.79
7 Utility Pumps SERIES / HP Submersible Use WATER WIZARD Submersible, water transfer or recirculation, water displays, air conditioners and machine tool coolants / HP shaded pole motor Garden hose adapter and removable inlet screen Epoxy coated cast aluminum housing Nylon volute Viton shaft seal Stainless steel shaft Capacity: ' ( m) Shut Off:.' ( m) Liquid Temperature: F (9 C) Discharge: " FNPT (. mm) Impeller: Nylon Lifetime oil supply Electrical: v, Hz v, Hz Operation: Manual or Automatic Item # Model Volts Cord Listing Switch Type On Level Off Level -ASP -ASP-LL -ASP-FS -MSPR -MSP -MSP 7 -MSP -MSP ' m '. m ' m ' m (black pump) ' m ' 7. m '. m '. m (w/o plug) UL / CSA UL / CSA UL / CSA Piggyback Diaphragm Piggyback Diaphragm Integral Float Switch " - 9". cm - cm " - " cm - 7. cm " - ". cm -. cm " - ". cm - cm." -.". cm -. cm " - ". cm -. cm UL / CSA UL / CSA UL / CSA UL / CSA For more information call..7.79
8 Small Submersible Pumps -EA SERIES Epoxy Encapsulated, Direct Drive Submersible or In-line Use PE- SERIES Epoxy Encapsulated, Direct Drive Submersible Use Water transfer or recirculation, water displays, and machine tool coolants Water transfer or recirculation, and water displays / HP epoxy encapsulated motor Glass-filled polyester housing Epoxy coated cast aluminum cover Nylon volute Viton shaft seal UL / CSA listed Capacity: 7 ' m Shut Off: 7' (. m) Liquid Temperature: F (9 C) Discharge: /" MNPT ( mm) Intake: /" MNPT & /" FNPT (.7 mm & mm) Impeller: Nylon -EA- Electrical: v, Hz,.A / HP epoxy encapsulated, direct drive motor Designed for continuous duty, submersible use only Polyester housing Polypropylene volute Nitrile shaft seal Snap off screen covers intake UL / CSA listed Capacity: 7 ' ( m) Shut Off: 7' (. m) Liquid Temperature: F (9 C) Discharge: /" MNPT ( mm) Intake: Smooth sump Impeller: Polypropylene PE- Electrical: v, Hz,.A Protection 7 -EA- ' m 7 ' m Impedance Protection PE- ' 7 ' m Impedance For more information call
9 Small Submersible Pumps PE- SERIES Epoxy Encapsulated, Direct Drive Submersible Use PE-.F SERIES Epoxy Encapsulated, Direct Drive Submersible Use Water transfer or recirculation, and water displays Water transfer or recirculation, and water displays / HP epoxy encapsulated, direct drive motor Designed for continuous duty, submersible use only Glass-filled polyester housing Nylon volute Viton shaft seal Snap off screen covers intake UL / CSA listed Capacity: ' ( m) Shut Off:.' (.7 m) Liquid Temperature: F (9 C) Discharge: /" MNPT ( mm) Intake: Hooded Impeller: Nylon PE-H Electrical: v, Hz,.A / HP epoxy encapsulated, direct drive motor Designed for continuous duty, submersible use only Glass-filled polyester housing Polypropylene volute Viton shaft seal Snap off screen covers intake UL / CSA listed Capacity: 7 ' (79 m) Shut Off:.' (. m) Liquid Temperature: F (9 C) Discharge: /" MNPT (9. mm) Intake: Smooth Impeller: Nylon PE-.F Electrical: v, Hz,.A Protection PE-H ' ' m Thermal overload Protection PE-.F ' 7 ' 79 m Thermal overload For more information call..7.79
10 Small Submersible Pumps P-AAA SERIES Oil-filled, Direct Drive Submersible Use -A SERIES Oil-filled, Direct Drive Submersible Use Water transfer or recirculation, and water displays Water transfer or recirculation, and water displays / HP oil-filled, direct drive motor Designed for continuous duty, submersible use only Glass-filled nylon housing, cover, and impeller Nitrile shaft seal UL / CSA listed (), UL listed () P-AAA / HP oil-filled, direct drive motor Designed for continuous duty, submersible use only Epoxy coated cast aluminum housing and cover Polypropylene volute and elbow Nitrile shaft seal Polyethylene screen UR listed (), UL listed () -AA Capacity: ' ( m) Shut-Off:.' (. m) Liquid Temperature: F (9 C) Discharge: /" MNPT ( mm) Intake: Smooth Impeller: Glass-filled nylon Electrical: v, Hz,.A v, /Hz,./.A Capacity: 7 ' ( m) Shut Off: 7' (. m) Liquid Temperature: F (9 C) Discharge: /" MNPT ( mm) Intake: Smooth Impeller: Polypropylene Electrical: v, Hz,.A Item # Model Volts Cord Protection P-AAA P-AAA P-AAA ' ' m '. m (w/o plug) Impedance Impedance Impedance Item # Model Volts Cord Protection -AA -A '.9 m ' Impedance Impedance For more information call
11 Small Submersible Pumps -MA SERIES Oil-filled, Direct Drive Submersible Use -A SERIES Oil-filled, Direct Drive Submersible or In-line Use Water transfer or recirculation, and water displays Water transfer or recirculation, and water displays / HP oil-filled, direct drive motor Designed for continuous duty, submersible use only Epoxy coated cast aluminum housing and cover Polypropylene volute Nitrile shaft seal Polypropylene screen UL listed (), UL / CSA listed () -MA / HP oil-filled, direct drive motor Designed for continuous duty, submersible or in-line use Epoxy coated cast aluminum housing and cover Nylon volute Nitrile shaft seal UL listed (), UL / CSA listed () -A Capacity: 7 ' ( m) Shut Off: 7' (. m) Liquid Temperature: F (9 C) Discharge: /" MNPT ( mm) Intake: Smooth Impeller: Polypropylene Electrical: v, Hz,.A Capacity: 7 ' m Shut Off: 7' (. m) Liquid Temperature: F (9 C) Discharge: /" MNPT ( mm) Intake: /" MNPT & /" FNPT (.7 mm & mm) Impeller: Nylon Electrical: v, Hz,.A Item # Model Volts Cord Protection -MA -MAT ' ' m Impedance Thermal overload Protection -A -AT ' ' m 7 ' m 7 ' m Thermal overload Thermal overload For more information call..7.79
12 Small Submersible Pumps - SERIES Oil-filled, Direct Drive Submersible or In-line Use SERIES Oil-filled, Direct Drive Submersible Use Water transfer or recirculation, and water displays Water transfer or recirculation, and water displays / HP oil-filled, direct drive motor Designed for continuous duty, submersible or in-line use Epoxy coated cast aluminum housing and cover Nylon volute Nitrile shaft seal UL listed - / HP oil-filled, direct drive motor Designed for continuous duty, submersible use only Epoxy coated cast aluminum housing and cover Polypropylene volute and elbow Nitrile shaft seal Polyethylene screen UL listed (), UR listed () Capacity: ' 77 m Shut Off: 7.' (. m) Liquid Temperature: F (9 C) Discharge: /" MNPT ( mm) Intake: /" MNPT & /" FNPT (.7 mm & mm) Impeller: Nylon Electrical: v, Hz,.A Capacity: ' (77 m) Shut Off: 7.' (. m) Liquid Temperature: F (9 C) Discharge: /" MNPT ( mm) Intake: Smooth Impeller: Polypropylene Electrical: v, Hz,.A v, /Hz,./.A Protection - ' ' 77 m Thermal overload Item # Model Volts Cord Protection -Y ' '. m (w/o plug) Impedance Thermal overload
13 Small Submersible Pumps E-N SERIES Oil-filled, Direct Drive Submersible Use E-N SERIES Oil-filled, Direct Drive Submersible or In-line Use Submersible, water transfer or recirculation, water displays and air conditioners / HP oil-filled motor Epoxy coated cast aluminum housing and cover Nylon volute Nitrile shaft seal Polypropylene screen UL / CSA listed (, ), UR listed () Capacity: ' ( m) Shut Off:.' (. m) Liquid Temperature: F (9 C) Discharge: /" MNPT ( mm) Intake: Hooded Impeller: Nylon E-N Electrical: v, Hz,.7A v, /Hz,./.9A Submersed or in-line use, water transfer or recirculation, water displays and air conditioners / HP oil-filled motor Epoxy coated cast aluminum housing and cover Nylon volute Nitrile shaft seal Polypropylene screen UL listed (, ), UR / C-CSA listed (), UL / CSA listed () Capacity: ' m Shut Off:.' (. m) Liquid Temperature: F (9 C) Discharge: /" MNPT ( mm) Intake: /" FNPT (. mm) Impeller: Nylon E-N Electrical: v, Hz,.7A v, /Hz,.9/.7A Item # Model Volts Cord Protection E-N E-NT E-NY ' ' m '. m (w/o plug) Thermal overload Thermal overload Thermal overload Item # Model Volts Cord Protection E-N E-N E-NY E-NT ' ' (black) '. m (w/o plug) ' m (water only) Thermal overload Thermal overload Thermal overload Thermal overload
14 Small Submersible Pumps E-N SERIES Oil-filled, Direct Drive Submersible or In-line Use E-N SERIES Oil-filled, Direct Drive Submersible or In-line Use Submersed or in-line use, water transfer or recirculation, water displays, air conditioners and machine tool coolants / HP oil-filled motor Epoxy coated cast aluminum housing and cover Nylon volute Stainless steel backplate Viton shaft seal Polypropylene screen UL / C-CSA listed Capacity: 7 ' m Shut Off:.' (. m) Liquid Temperature: F (9 C) Discharge: /" MNPT (.7 mm) Intake: /" FNPT (9 mm) Impeller: Nylon E-N Electrical: v, Hz,.A Submersed or in-line use, water transfer or recirculation, water displays, air conditioners and machine tool coolants / HP oil-filled motor Epoxy coated cast aluminum housing and cover Nylon volute Aluminum backplate Viton shaft seal Polypropylene screen UL listed (, ), UL / CSA listed () Capacity: ' 9 m Shut Off: 7.' (. m) Liquid Temperature: F (9 C) Discharge: /" MNPT (.7 mm) Intake: /" FNPT (.7 mm) Impeller: Nylon E-N Electrical: v, Hz,.A Item # Model Volts Cord Protection E-N ' m Thermal overload Item # Model Volts Cord Protection E-N E-N E-NT ' ' ' m Thermal overload Thermal overload Thermal overload 7 For more information call..7.79
15 Small Submersible Pumps E-NR SERIES Oil-filled, Direct Drive Submersible or In-line Use E-NRY SERIES Oil-filled, Direct Drive Submersible or In-line Use Submersed or in-line use, water transfer or recirculation, water displays, air conditioners and machine tool coolants / HP oil-filled heavy duty motor Epoxy coated cast aluminum housing and cover Nylon volute Aluminum backplate Viton shaft seal Polypropylene screen UL listed E-NR Submersed or in-line use, water transfer or recirculation, water displays, air conditioners and machine tool coolants / HP oil-filled heavy duty motor Epoxy coated cast aluminum housing and cover Nylon volute Aluminum backplate Viton shaft seal Polypropylene screen UR / C-CSA listed E-NRY Capacity: 7 ' m Shut Off:.' (. m) Liquid Temperature: F (9 C) Discharge: /" MNPT (.7 mm) Intake: /" FNPT (.7 mm) Impeller: Nylon Electrical: v, Hz,.A Capacity: ' 7 m Shut Off: ' (. m) Liquid Temperature: F (9 C) Discharge: /" MNPT (.7 mm) Intake: /" FNPT (.7 mm) Impeller: Nylon Electrical: v, /Hz,.7/.A Item # Model Volts Cord Protection E-NR ' Thermal overload Item # Model Volts Cord Protection E-NRY '. m (w/o plug) Thermal overload 7 7 For more information call..7.79
16 Small Submersible Pumps E-R SERIES Oil-filled, Direct Drive Submersible or In-line Use E-N SERIES Oil-filled, Direct Drive Submersible Use Submersed or in-line use, water transfer or recirculation, water displays, air conditioners and machine tool coolants / HP oil-filled motor Epoxy coated cast aluminum housing and cover Nylon volute Aluminum backplate Viton shaft seal Polypropylene screen UL listed E-R Submersible, water transfer or recirculation, water displays, air conditioners and machine tool coolants / HP oil-filled motor Epoxy coated cast aluminum housing and cover Nylon volute Aluminum backplate Viton shaft seal UL listed (), UL / CSA listed () E-N Capacity: ' 97 m Shut Off:.9' (7.9 m) Liquid Temperature: F (9 C) Discharge: /" MNPT (.7 mm) Intake: /" FNPT (.7 mm) Impeller: Nylon (high pressure) Electrical: v, Hz,.A Capacity: 7 ' ( m) Shut Off:.' (7 m) Liquid Temperature: F (9 C) Discharge: /" MNPT (.7 mm) Intake: /" FNPT (9 mm) Impeller: Nylon Electrical: v, Hz,.A Item # Model Volts Cord Protection E-R ' Thermal overload Item # Model Volts Cord Protection E-N E-NT ' ' m Thermal overload Thermal overload For more information call..7.79
17 Small Submersible Pumps E-NR SERIES Oil-filled, Direct Drive Submersible Use NK- SERIES Oil-filled, Direct Drive Submersible Use Submersible, water transfer or recirculation, water displays, air conditioners and machine tool coolants / HP oil-filled heavy duty motor Epoxy coated cast aluminum housing and cover Nylon volute Aluminum backplate Viton shaft seal UL listed (), UR listed () E-NR Submersible, water transfer or recirculation, water displays, air conditioners, machine tool coolants, and mild acids / HP oil-filled motor Nylon housing, cover and volute Viton shaft seal Polyethylene screen NK- Capacity: ' ( m) Shut Off:.' (7. m) Liquid Temperature: F (9 C) Discharge: /" MNPT (.7 mm) Intake: /" FNPT (9 mm) Impeller: Nylon Electrical: v, Hz,.A v, /Hz,./.A Capacity: ' (79 m) Shut Off:.' (. m) Liquid Temperature: F (9 C) Discharge: /" MNPT ( mm) Intake: Smooth sump Impeller: Nylon Electrical: v, Hz,.A Item # Model Volts Cord Protection E-NR E-NRY ' '. m (w/o plug) Thermal overload Thermal overload Protection NK- ' ' 79 m Thermal overload For more information call..7.79
18 Small Submersible Pumps NK- SERIES Oil-filled, Direct Drive Submersible Use Submersible, water transfer or recirculation, water displays, air conditioners, machine tool coolants, and mild acids / HP oil-filled motor Nylon housing, cover and volute Viton shaft seal Polyethylene screen Capacity: ' ( m) Shut Off:.' (.7 m) Liquid Temperature: F (9 C) Discharge: /" MNPT ( mm) Intake: Smooth sump. For more information call Impeller: Nylon Electrical: v, Hz,.7A v, /Hz,.9/.7A Protection 7 NK- 77 NK- 7 NK- ' '. m '. m (w/o plug) NK- ' m ' m ' m Thermal overload Thermal overload Thermal overload Liquid Temperature: Hot water up to F (. C) Discharge: /" MNPT ( mm) S/S; /" MNPT (.7 mm) S/S9/S S SERIES Oil-filled, Direct Drive Submersible or In-line Use Submersible, water transfer or recirculation, water displays, air conditioners, machine tool coolants, and mild acids Premium stainless steel and bronze construction Nylon volute and impeller All models feature a flow adjuster Extremely quiet operation Can be used in hot water applications up to F (. C) Item # Model Volts Amps Watts Cord Capacity Protection Shut Off ST- ST-.9 ' Thermal 9 m Overload ' ST- ST-. 9 ' Thermal m Overload ' ST- ST-. ' Thermal m Overload ' S9T- S9T-. ' m Overload ' ST- ST-. ST- ST-. Suitable for fresh, salt, chlorinated or brominated water (max - ppm) culus listed Two-year warranty ST- and ST- includes CFS pre-filter Intake: /" MNPT (.7 mm) S/S; /" MNPT (9 mm) S/S9/S Electrical: v, Hz ' m Thermal Overload.... ' continued on the next page 7
19 Small Submersible Pumps S SERIES Oil-filled, Direct Drive Submersible or In-line Use continued S9T-* ST- ST- * SPB Mounting bracket sold separately (shown on image) 9 S9T- ST- 9 9 For more information call..7.79
20 Specialty Pumps Machine Tool Coolant Units Drill presses, tool grinders, tapping machines, cut-off saws, bench mills, lathes / HP fan-cooled motor Vertical machine coolant Nylon volute VMC- Capacity: ' 9 m Liquid Temperature: F (9 C) Impeller: Nylon Electrical: v, Hz, A Item # Model Volts Cord Protection VMC- '. m Thermal overload Little Giant Machine Tool Coolant Units are designed for virtually any machine tool operational need. Units are engineered so that coolant flow can be regulated to desired amount, or completely shut off without harmful effects to the motor. MTC units use only centrifugal-type pumps. It is recommended that all machine tool pumps have Viton shaft seals, if shaft seal is required. For more information call
21 Specialty Pumps Machine Tool Coolant Tanks Drill presses, tool grinders, tapping machines, cut-off saws, bench mills, lathes -gallon (.9 liter) polyethylene tank Metal chip collector basket and baffle ' () plastic hose, plastic flex nozzle and brass control valve, plus all adapters and fittings for use with recommended pumps (see chart below) Pump not included* MCT-P Series Specifications Item # Model MCT-P Recommended Pumps for MCT-P (GPH at v, Hz) Item # Model For MCT Unit 7 -YS MCT-P 7 LPH NK- MCT-P 7 NK- MCT-P E-N MCT-P E-N MCT-P -MSP MCT- 7 -CIM-R MCT- GPH Water Soluble Oil GPH SSU/Cutting Oil GPH SSU/Cutting Oil ' ' ' ' Shut off ' ' ' ' Shut off ' ' ' ' Shut off 7 LPH LPH 7 LPH 7 LPH LPH 7 LPH 7 LPH 7 LPH 7 9 LPH LPH 9 LPH 77 LPH 7 7 LPH LPH LPH LPH LPH 9 LPH 9 7 LPH 7 LPH LPH 9 7 LPH 79 LPH 7 LPH 7 LPH 7.'. m.'. m.'.7 m.'.9 m.' 7. m.'. m.'. m 9 LPH 9 LPH LPH 9 7 LPH 9 LPH 9 LPH LPH *NOTE: The MCT-P unit does not include pump. Pump must be purchased in addition to unit. LPH LPH 9 9 LPH LPH 9 7 LPH 9 LPH LPH 9 7 LPH LPH 7 LPH LPH 7 LPH LPH 7 LPH 9 LPH 9 LPH.'. m.'. m.'.9 m.'. m.'. m.'. m.7'. m 7 LPH 7 LPH 7 LPH 9 LPH LPH 7 9 LPH 7 LPH 7 LPH 7 LPH LPH LPH LPH 7 7 LPH LPH LPH 7 7 LPH.7'. m 7.'. m.'. m.'. m For more information call..7.79
22 Specialty Pumps Machine Tool Coolant Tanks Drill presses, tool grinders, tapping machines, cut-off saws, bench mills, lathes -gallon (7. liter) metal tank with baffle ' (. cm) neoprene hose with brass fittings, plastic flex nozzle and brass control valve Removable chip collector tray and splash deflector, plus all adapters and fittings for use with recommended pumps (see chart below) Pump not included* MCT- Series Specifications Item # Model MCT- Recommended Pumps for MCT- (GPH at v, Hz) Item # Model For MCT Unit -YS MCT-P NK- MCT-P 7 NK- MCT-P E-N MCT-P E-N MCT-P -MSP MCT- 7 -CIM-R MCT- GPH Water Soluble Oil GPH SSU/Cutting Oil GPH SSU/Cutting Oil ' ' ' ' Shut off ' ' ' ' Shut off ' ' ' ' Shut off 7 7 LPH 7 LPH LPH 7 LPH 7 LPH LPH 7 LPH 7 LPH 7 LPH 7 9 LPH LPH 9 LPH 77 LPH 7 7 LPH LPH LPH LPH LPH 9 LPH 9 7 LPH 7 LPH LPH 9 7 LPH 79 LPH 7 LPH 7 LPH 7.'. m.'. m.'.7 m.'.9 m.' 7. m.'. m.'. m 9 LPH 9 LPH LPH 9 7 LPH 9 LPH 9 LPH LPH * NOTE: The MCT- unit does not include pump. Pump must be purchased in addition to unit. LPH LPH 9 9 LPH LPH 9 7 LPH 9 LPH LPH 9 7 LPH LPH 7 LPH LPH 7 LPH LPH 7 LPH 9 LPH 9 LPH.'. m.'. m.'.9 m.'. m.'. m.'. m.7'. m 7 LPH 7 LPH 7 LPH 9 LPH LPH 7 9 LPH 7 LPH 7 LPH 7 LPH LPH LPH LPH 7 7 LPH LPH LPH 7 7 LPH.7'. m 7.'. m.'. m.'. m For more information call..7.79
23 Specialty Pumps Open Motor Pumps High Pressure Pumps Non-Submersible Use Non-Submersible Use In-line use in hot drink dispenser, fountain and fresh water applications. Largely used in water displays / HP open motor Nylon volute Viton shaft seal Stainless steel shaft Aluminum mounting bracket -AA-OM Non-submersible, high pressure, carpet cleaning, dispenser displays, and pressure washers / HP fan-cooled motor Thermoplastic housing Nylon volute Carbon/ceramic shaft seal Double-insulated motor (non-replaceable brushes last - hours) Includes bypass adapter UR listed () -OM Capacity: ' m Shut Off: 7' (. m) Liquid Temperature: F (9 C) Discharge: /" MNPT ( mm) Intake: /" FNPT & /" MNPT ( mm &.7 mm) Impeller: Nylon Electrical: v, Hz,.A Capacity: 7 ' m Shut Off: ' (.7 m) Liquid Temperature: F (9 C) Discharge: /" barbed OD (9. mm) Intake: /" barbed OD (9. mm) Impeller: PPS impeller Electrical: v, Hz,.A v, /Hz,.A Item # Model Volts Lead Wires -AA-OM ". cm Item # Model Volts Lead Wires -OM -OM " cm " cm Replacement Seal Kit Item # Model 99 -OM-SK Housing, carbon seal, impeller with ceramic seal and O-ring For more information call..7.79
24 Specialty Pumps Parts Washer Pumps Submersible Use CAUTION: The low flash point of these combustible liquids does present a moderate fire hazard. Operating the pump fully submerged offers added protection from fire risk. For other solvent handling precautions, consult the material safety data sheet (OSHA- form, or equivalent), for the solvent use. Use only UL approved Metal Parts Cleaning Solvents. The use of fluids such as gasoline, and lower flash point solvents is dangerous and may cause explosions or fire. Solvents other than UL approved metal parts cleaning solvents will void the warranty of this product. Submersible for pumping unheated metal parts cleaning solvent which is UL classified as PJQU / HP epoxy encapsulated motor Cast aluminum/polyester housing Nylon volute and screen Viton shaft seal /" (9. mm) conduit fitting UR / C-CSA listed Capacity: 7 ' m Shut Off: 7' (. m) Liquid Temperature: F (9 C) Discharge: /" MNPT ( mm) Impeller: Nylon Electrical: v, Hz,.A -EAYS Protection ' 7 ' -EAYS Impedance (w/o plug) LPH Submersible for pumping unheated metal parts cleaning solvent which is UL classified as PJQU / HP oil-filled motor Cast aluminum housing Nylon volute Viton shaft seal Polyethylene screen /" (.7 mm) conduit fitting UR / C-CSA listed (, ) Capacity: ' 77 m Shut Off: 7.' (. m) Liquid Temperature: F (9 C) Discharge: /" MNPT ( mm) Impeller: Nylon Electrical: v, Hz,.A v, /Hz,.A Protection ' ' -YS Thermal overload (w/o plug) 77 LPH -Y -YS ' (w/o plug) ' (w/o plug) -YS ' 77 LPH ' 77 LPH Thermal overload Thermal overload
25 Specialty Pumps Parts Washer Pumps Specialty Pumps Acid Pumps Submersible Use Submersible or In-line Use Submersible for pumping unheated metal parts cleaning solvent which is UL classified as PJQU / HP oil-filled motor Cast aluminum housing Nylon volute Viton shaft seal Nylon screen /" (.7 mm) conduit fitting UR / C-CSA listed E-NYS Submersible for pumping water or machine oils. In-line when pumping weak acids and chemicals, fruit juices, cleaning solvent, anti-freeze and fluids with a ph factor of to 7 / HP oil-filled motor Epoxy coated cast aluminum housing Nylon volute Inner and outer Viton shaft seals Adapter included for /" (.7 mm) barbed intake E-NDVR Capacity: ' m Shut Off:.' (. m) Liquid Temperature: F (9 C) Discharge: /" MNPT ( mm) Intake: Hooded Impeller: Nylon Electrical: v, Hz,.7A Protection ' ' E-NYS Thermal overload (w/o plug) LPH Capacity: ' m Shut Off:.' (. m) Liquid Temperature: F (9 C) Discharge: /" MNPT ( mm) Intake: /" FNPT (9. mm) Impeller: Nylon Electrical: v, Hz,.7A Protection E-NDVR ' ' LPH Thermal overload
26 Specialty Pumps Circulator Pumps Non-Submersible Solar heating, heat exchange units, and open or closed commercial and domestic hot water recirculating systems / HP motor (dual fan-cooled, RPM) Bronze pump head Oversize sleeve bearings Stainless steel shaft and magnet separator Silicon O-ring Capacity: ' m Shut Off: ' (. m) Liquid Temperature: F ( C) Discharge: /" MNPT (.7 mm) Intake: /" MNPT (9. mm) Impeller: PPS Electrical: v, Hz,.A Maximum system pressure designed for PSIG in closed loop system Indoor use only UR / C-CSA listed Item # Model Volts Lead Wires Capacity Protection 79 CMD--B ". cm CMD--B ' m Impedance Solar heating, heat exchange units, and open or closed commercial and domestic hot water recirculating systems / HP motor (dual fan-cooled, RPM) Bronze pump head Oversize sleeve bearings Stainless steel shaft and magnet separator Silicon O-ring Capacity: 7 ' m Shut Off: ' (. m) Liquid Temperature: F ( C) Discharge: /" MNPT (.7 mm) Intake: /" MNPT (9. mm) Impeller: PPS Electrical: v, Hz,.A Maximum system pressure designed for PSIG in closed loop system Indoor use only UR / C-CSA listed Item # Model Volts Lead Wires Capacity Protection 79 CMD--B CMD--B ' 7 ' m Thermal overload For more information call..7.79
27 MD SERIES / HP -AA-MD Circulation of mildly corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other mildly corrosive chemicals and solutions that are compatible with the pump's material of construction / HP open motor Glass-filled polypropylene magnet housing Glass-filled polypropylene volute. specific gravity Viton O-ring Rulon J (Teflon ) thrust washers Stainless steel shaft RPM: (), 9/ () Capacity:.7 GPM (. LPM) Shut Off:.' (. m) Liquid Temperature: F ( C) Discharge: /" OD (.7 mm) Intake: /" OD (.7 mm) UR / C-CSA listed (), UR listed () Impeller: Glass-filled polypropylene & Ceramagnet A (Barium Ferrite) Electrical: v, Hz,.A v, /Hz,.A Item # Model Volts Lead Wires Capacity '.7 GPM -AA-MD.9 m (w/o plug). LPM -AA-MD -AA-MD Pump head less motor '.9 m (w/o plug).7 GPM. LPM or volt, Hz... For more information call..7.79
28 MD SERIES / HP Submersible or In-line Use -EUAA-MD Circulation of mildly corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other mildly corrosive chemicals and solutions that are compatible with the pump's material of construction / HP encapsulated motor Glass-filled polypropylene magnet housing Glass-filled polypropylene volute. specific gravity Nitrile O-ring Rulon J (Teflon ) thrust washers Ceramic shaft Capacity:. GPM (9. LPM) Shut Off: ' (. m) Liquid Temperature: F ( C) Discharge: /" OD (.7 mm) Intake: /" OD (.7 mm) Impeller: Glass-filled polypropylene & Ceramagnet A (Barium Ferrite) UL / CSA listed for fresh and salt water Electrical: v, Hz,.A -EUAA-MD '. GPM 9. LPM volt, Hz... For more information call
29 MD SERIES /7 HP -MD Circulation of mildly corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other mildly corrosive chemicals and solutions that are compatible with the pump's material of construction. /7 HP open FC motor Glass-filled polypropylene magnet housing Glass-filled polypropylene volute. specific gravity Nitrile O-ring Titanium thrust washers and shaft UR / C-CSA listed (9) RPM: (9), 7/ (9) Capacity:. GPM (. LPM) Shut Off:.' (. m) Liquid Temperature: F ( C) Discharge: /" OD (.7 mm) Intake: /" OD (.7 mm) Impeller: Glass-filled polypropylene & Ceramagnet A (Barium Ferrite) Electrical: v, Hz,.A v, /Hz,.7/.A 9 -MD 9 -MD 99 -MD Pump head less motor ' ' (w/o plug). GPM. LPM. GPM. LPM 9 9. or volt, Hz... For more information call..7.79
30 MD SERIES / HP -MD Circulation of mildly corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other mildly corrosive chemicals and solutions that are compatible with the pump's material of construction / HP open FC motor Glass-filled polypropylene magnet housing Glass-filled polypropylene volute. specific gravity Nitrile O-ring Titanium thrust washers and shaft UR / C-CSA listed (, ) RPM: (), 7/ () Capacity:. GPM ( LPM) Shut Off:.' (. m) Liquid Temperature: F ( C) Discharge: /" MNPT (.7 mm) Intake: /" FNPT (.7 mm) Impeller: Glass-filled polypropylene & Ceramagnet A (Barium Ferrite) Electrical: v, Hz,.A v, /Hz,./.A or volt, Hz -MD -MD 9 -MD Pump head less motor ' ' (w/o plug). GPM LPM. GPM LPM For more information call
31 MD SERIES / HP -MD Circulation of mildly corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other mildly corrosive chemicals and solutions that are compatible with the pump's material of construction / HP open FC motor Glass-filled polypropylene magnet housing Glass-filled polypropylene volute. specific gravity Nitrile O-ring Titanium thrust washers and shaft UR / C-CSA listed () RPM: Capacity: 9. GPM (. LPM) Shut Off:.' (.9 m) Liquid Temperature: F ( C) Discharge: /" MNPT (.7 mm) Intake: /" FNPT (.7 mm) Impeller: Glass-filled polypropylene & Ceramagnet A (Barium Ferrite) Electrical: v, Hz,.A 9 volt, Hz -MD 9 -MD Pump head less motor ' 9. GPM. LPM For more information call..7.79
32 MD SERIES / HP -MDX Circulation of mildly corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other mildly corrosive chemicals and solutions that are compatible with the pump's material of construction / HP open FC motor Glass-filled polypropylene magnet housing Glass-filled polypropylene volute /" OD (.9 mm) discharge. specific gravity Nitrile O-ring Titanium thrust washers and shaft UR / C-CSA listed RPM: Capacity: 7. GPM (. LPM) Shut Off: 9' (. m) Liquid Temperature: F ( C) Discharge: /" OD (.9 mm) Intake: /" OD (.9 mm) Impeller: Glass-filled polypropylene & Ceramagnet A (Barium Ferrite) Electrical: v, Hz,.A volt, Hz -MDX ' 7. GPM. LPM For more information call..7.79
33 MD SERIES / HP X-MDX Circulation of mildly corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other mildly corrosive chemicals and solutions that are compatible with the pump s material of construction / HP open FC motor Glass-filled polypropylene magnet housing Glass-filled polypropylene volute. specific gravity Nitrile O-ring Titanium thrust washers and shaft UR / C-CSA listed RPM: Capacity:.7 GPM (. LPM) Shut Off: 7' (. m) Liquid Temperature: F ( C) Discharge: /" OD (.9 mm) Intake: /" OD (.9 mm) Impeller: Glass-filled polypropylene & Ceramagnet A (Barium Ferrite) Electrical: v, Hz,.9A..... X-MDX '.7 GPM. LPM For more information call..7.79
34 MD SERIES / HP TE--MD Circulation of mildly corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other mildly corrosive chemicals and solutions that are compatible with the pump's material of construction / HP TEFC motor Glass-filled polypropylene magnet housing Glass-filled polypropylene volute. specific gravity Nitrile O-ring Titanium thrust washers and shaft UR / C-CSA listed RPM: 7/ Capacity: 9. GPM (7. LPM) Shut Off:.' (.9 m) Liquid Temperature: F ( C) Discharge: /" MNPT (.7 mm) Intake: /" FNPT (.7 mm) Impeller: Glass-filled polypropylene & Ceramagnet A (Barium Ferrite) Electrical: v, /Hz,./.A 9 volt, Hz ' 9. GPM TE--MD (w/o plug) 7. LPM For more information call..7.79
35 MD SERIES / HP -MD Circulation of mildly corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other mildly corrosive chemicals and solutions that are compatible with the pump's material of construction / HP open FC motor Glass-filled polypropylene magnet housing Glass-filled polypropylene volute. specific gravity Nitrile O-ring Titanium thrust washers and shaft UR / C-CSA listed (, ) RPM: () () Capacity:. GPM (. LPM) Shut Off:.7' (7. m) Liquid Temperature: F ( C) Discharge: /" MNPT (.7 mm) Intake: /" FNPT (.7 mm) Impeller: Glass-filled polypropylene & Ceramagnet A (Barium Ferrite) Electrical: v, Hz,.A v, Hz,.A 7 or volt, Hz -MD -MD 9 -MD Pump head less motor ' ' (w/o plug). GPM. LPM. GPM. LPM For more information call..7.79
36 MD SERIES / HP -MD Circulation of mildly corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other mildly corrosive chemicals and solutions that are compatible with the pump's material of construction / HP PSC open FC motor Glass-filled polypropylene magnet housing Glass-filled polypropylene volute. specific gravity Nitrile O-ring Titanium thrust washers and shaft UR / C-CSA listed (, ) RPM: () / () Capacity:. GPM (7. LPM) Shut Off:.' (. m) Liquid Temperature: F ( C) Discharge: /" MNPT (.7 mm) Intake: /" FNPT (.7 mm) Impeller: Glass-filled polypropylene & Ceramagnet A (Barium Ferrite) Electrical: v, Hz,.A v, /Hz,./.A -MD -MD 9 -MD Pump head less motor ' ' (w/o plug). GPM 7. LPM. GPM 7. LPM or volt, Hz For more information call..7.79
37 SC SERIES / HP.-MDI-SC Circulation of moderately corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other moderately corrosive chemicals and solutions that are compatible with the pump's material of construction / HP open FC motor Glass-filled polypropylene magnet housing Glass-filled polypropylene volute. specific gravity Viton O-ring Ceramic thrust washers and shaft UR / C-CSA listed RPM: Capacity:. GPM (. LPM) Shut Off:.' (. m) Liquid Temperature: F ( C) Discharge: /" MNPT ( mm) Intake: /" MNPT (9 mm) & /" FNPT (9. mm) Impeller: Glass-filled polypropylene Electrical: v, Hz,.A v, /Hz,.7/.A 9.-MDI-SC 9.-MDI-SC ' ' (w/o plug). GPM. LPM. GPM. LPM or volt, Hz For more information call..7.79
38 SC SERIES / HP Submersible Use Only PE-.-MDI-SC Circulation of moderately corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other moderately corrosive chemicals and solutions that are compatible with the pump's material of construction / HP encapsulated motor Glass-filled polypropylene magnet housing Glass-filled polypropylene volute. specific gravity Nitrile O-ring Ceramic thrust washers and shaft Polyester motor case RPM: Capacity:. GPM (. LPM) Shut Off:.' (.9 m) Liquid Temperature: 77 F ( C) Discharge: /" MNPT ( mm) Intake: /" MNPT (.7 mm) Stainless steel screws Polyethylene intake screen UR / C-CSA listed Impeller: Glass-filled polypropylene Electrical: v, Hz,.9A 9 PE-.-MDI-SC '. GPM. LPM For more information call
39 SC SERIES / HP or / HP -MD-SC Circulation of moderately corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other moderately corrosive chemicals and solutions that are compatible with the pump's material of construction / HP open FC motor () / HP open FC motor () Glass-filled polypropylene magnet housing Glass-filled polypropylene volute. specific gravity Nitrile O-ring Ceramic thrust washers and shaft RPM: 9 () 7/ () Capacity:. GPM (. LPM) Shut Off:.' (. m) Liquid Temperature: F ( C) Discharge: /" MNPT (.7 mm) Intake: /" FNPT (.7 mm) UR / C-CSA listed (, ) Impeller: Glass-filled polypropylene Electrical: v, Hz,.A v, /Hz,./.A -MD-SC -MD-SC 9 -MD-SC Pump head less motor ' ' (w/o plug). GPM. LPM. GPM. LPM or volt, Hz For more information call..7.79
40 SC SERIES / HP -MDIX-SC Circulation of moderately corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other moderately corrosive chemicals and solutions that are compatible with the pump's material of construction / HP open FC motor Glass-filled polypropylene magnet housing Glass-filled polypropylene volute. specific gravity Nitrile O-ring Ceramic thrust washers and shaft UR / C-CSA listed RPM: Capacity:. GPM (. LPM) Shut Off:.' (. m) Liquid Temperature: F ( C) Discharge: " MNPT (. mm) Intake: " FNPT (. mm) Impeller: Glass-filled polypropylene Electrical: v, Hz,.A MDIX-SC '. GPM. LPM For more information call
41 SC SERIES / HP -MD-SC Circulation of moderately corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other moderately corrosive chemicals and solutions that are compatible with the pump's material of construction / HP open FC motor Glass-filled polypropylene magnet housing Glass-filled polypropylene volute. specific gravity Nitrile O-ring Ceramic thrust washers and shaft UR / C-CSA listed (, ) RPM: () ()) Capacity:. GPM (7. LPM) Shut Off:.9' (. m) Liquid Temperature: F ( C) Discharge: /" MNPT (.7 mm) Intake: /" FNPT (9 mm) Impeller: Glass-filled polypropylene Electrical: v, Hz,.A v, Hz,.7A -MD-SC -MD-SC 97 -MD-SC Pump head less motor ' ' (w/o plug). GPM 7. LPM. GPM 7. LPM or volt, Hz 7 For more information call..7.79
42 SC SERIES / HP -MDIX-SC Circulation of moderately corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other moderately corrosive chemicals and solutions that are compatible with the pump's material of construction / HP TEPSC motor Glass-filled polypropylene magnet housing Glass-filled polypropylene volute. specific gravity Nitrile O-ring Ceramic thrust washers and shaft UR / C-CSA listed RPM: Capacity:. GPM (7 LPM) Shut Off: ' (. m) Liquid Temperature: F ( C) Discharge: " MNPT (. mm) Intake: " FNPT (. mm) Impeller: Glass-filled polypropylene Electrical: v, Hz,.9A 7 9 -MDIX-SC '. GPM 7 LPM For more information call..7.79
43 SC SERIES / HP -MD-SC Circulation of moderately corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other moderately corrosive chemicals and solutions that are compatible with the pump's material of construction / HP open FC PSC motor Glass-filled polypropylene magnet housing Glass-filled polypropylene volute. specific gravity Nitrile O-ring Ceramic thrust washers and shaft UR / C-CSA listed () RPM: Capacity: GPM ( LPM) Shut Off: ' (7. m) Liquid Temperature: F ( C) Discharge: /" MNPT (.7 mm) Intake: " FNPT (. mm) Impeller: Glass-filled polypropylene Electrical: v, Hz,.7A 7 -MD-SC 9 -MD-SC Pump head less motor ' GPM LPM For more information call..7.79
44 SC SERIES / HP -MDIX-SC Circulation of moderately corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other moderately corrosive chemicals and solutions that are compatible with the pump's material of construction / HP open FC PSC motor Glass-filled polypropylene magnet housing Glass-filled polypropylene volute. specific gravity Nitrile O-ring Ceramic thrust washers and shaft UR / C-CSA listed RPM: Capacity: GPM (. LPM) Shut Off: 7' (. m) Liquid Temperature: F ( C) Discharge: " MNPT (. mm) Intake: " FNPT (. mm) Impeller: Glass-filled polypropylene Electrical: v, Hz,.A MDIX-SC ' GPM. LPM For more information call..7.79
45 SC SERIES / HP TE--MD-SC Circulation of moderately corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other moderately corrosive chemicals and solutions that are compatible with the pump's material of construction / HP TEFC PSC motor Glass-filled polypropylene magnet housing Glass-filled polypropylene volute. specific gravity Nitrile O-ring Ceramic thrust washers and shaft UR / C-CSA listed RPM: () 7/ () Capacity: GPM ( LPM) Shut Off: ' (7. m) Liquid Temperature: F ( C) Discharge: /" MNPT (.7 mm) Intake: " FNPT (. mm) Impeller: Glass-filled polypropylene Electrical: v, Hz,.7A v, /Hz,./.7A TE--MD-SC TE--MD-SC ' ' (w/o plug) GPM LPM GPM LPM 7 or volt, Hz For more information call..7.79
46 SC SERIES / HP TE--MDX-SC Circulation of moderately corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other moderately corrosive chemicals and solutions that are compatible with the pump's material of construction / HP TEFC PSC motor Glass-filled polypropylene magnet housing Glass-filled polypropylene volute. specific gravity Nitrile O-ring Ceramic thrust washers and shaft UR / C-CSA listed RPM: 7/ Capacity:. GPM (. LPM) Shut Off: 7.' (. m) Liquid Temperature: F ( C) Discharge: " MNPT (. mm) Intake: " FNPT (. mm) Impeller: Glass-filled polypropylene Electrical: v, /Hz,.A '. GPM TE--MDX-SC (w/o plug). LPM 7 9. volt, Hz For more information call..7.79
47 SC SERIES / HP -MD-SC Circulation of moderately corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other moderately corrosive chemicals and solutions that are compatible with the pump's material of construction / HP open FC PSC motor Glass-filled polypropylene magnet housing Glass-filled polypropylene volute. specific gravity Nitrile O-ring Ceramic thrust washers and shaft UR / C-CSA listed (, ) RPM: () / () Capacity: 7. GPM (. LPM) Shut Off: 7.' (. m) Liquid Temperature: F ( C) Discharge: /" MNPT (.7 mm) Intake: " FNPT (. mm) Impeller: Glass-filled polypropylene Electrical: v, /Hz, A v, /Hz, /.A -MD-SC -MD-SC 9 -MD-SC Pump head less motor ' ' (w/o plug) 7. GPM. LPM 7. GPM. LPM 9 or volt, Hz For more information call..7.79
48 SC SERIES / HP TE--MD-SC Circulation of moderately corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other moderately corrosive chemicals and solutions that are compatible with the pump's material of construction / HP TEFC PSC motor Glass-filled polypropylene magnet housing Glass-filled polypropylene volute. specific gravity Nitrile O-ring Ceramic thrust washers and shaft UR / C-CSA listed () RPM: / Capacity: GPM (7.7 LPM) Shut Off: 9.' (9 m) Liquid Temperature: F ( C) Discharge: /" MNPT (.7 mm) Intake: " FNPT (. mm) Impeller: Glass-filled polypropylene Electrical: v, /Hz,./A v, /Hz,./.A ' GPM TE--MD-SC / Cord not installed 7.7 LPM 9 TE--MD-SC Pump head less motor 7 or volt, Hz 9 7 For more information call
49 SC SERIES / HP TE-.-MD-SC Circulation of moderately corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other moderately corrosive chemicals and solutions that are compatible with the pump's material of construction / HP TEFC motor Glass-filled polypropylene volute Glass-filled polyphenylene sulfide backplate. specific gravity Viton O-ring Ceramic thrust washers and shaft UR / C-CSA listed () RPM: / Capacity:.7 GPM ( LPM) Shut Off:.' (. m) Liquid Temperature: F ( C) Discharge: /" MNPT (9 mm) Intake: " FNPT (. mm) Impeller: Glass-filled polypropylene w/ carbon bushing Electrical: v, /Hz,./.A v, /Hz,./.A TE-.-MD-SC / 9 TE-.-MD-SC Pump head less motor Not included.7 GPM LPM NOTE: Although no pump should be operated dry, the TE-.-MD-SC models have a run-dry capability of up to eight hours without damage. or volt, Hz For more information call..7.79
50 SC SERIES / HP TE--MD-SC Circulation of moderately corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other moderately corrosive chemicals and solutions that are compatible with the pump's material of construction / HP TEFC motor Glass-filled polypropylene volute. specific gravity Glass-filled polyphenylene sulfide backplate Viton O-ring Ceramic thrust washers and shaft UR / C-CSA listed () RPM: / Capacity: GPM (. LPM) Shut Off: ' (. m) Liquid Temperature: F ( C) Discharge: /" MNPT (9 mm) Intake: " FNPT (. mm) Impeller: Glass-filled polypropylene w/ carbon bushing Electrical: v, /Hz,./9.A v, /Hz,./.7A TE--MD-SC / 9 TE--MD-SC Pump head less motor Not included GPM. LPM NOTE: Although no pump should be operated dry, the TE--MD-SC models have a run-dry capability of up to eight hours without damage. or volt, Hz 9 For more information call
51 SC SERIES / HP TE-7-MD-SC Circulation of moderately corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other moderately corrosive chemicals and solutions that are compatible with the pump's material of construction / HP TEFC motor Glass-filled polypropylene volute Glass-filled polyphenylene sulfide backplate. specific gravity Viton O-ring Ceramic thrust washers and shaft UR / C-CSA listed RPM: / Capacity: GPM (. LPM) Shut Off:.' (7. m) Liquid Temperature: F ( C) Discharge: " MNPT (. mm) Intake: -/" FNPT ( mm) Impeller: Glass-filled polypropylene w/ carbon bushing Electrical: v, /Hz,./.A v, /Hz,./.9A 7 TE-7-MD-SC / Not included GPM. LPM NOTE: Although no pump should be operated dry, the TE-7-MD-SC models have a run-dry capability of up to eight hours without damage. 7 or volt, Hz For more information call..7.79
52 HC SERIES / HP -MD-HC Circulation of highly corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other highly corrosive chemicals and solutions that are compatible with the pump's material of construction / HP open FC motor Glass-filled polyphenylene sulfide magnet housing and volute. specific gravity Viton O-ring Ceramic thrust washers and shaft UR / C-CSA listed (, ) RPM: () 7/ () Capacity:. GPM (. LPM) Shut Off:.' (. m) Liquid Temperature: F (9. C) Discharge: /" MNPT (.7 mm) Intake: /" FNPT (.7 mm) Impeller: Glass-filled polyphenylene sulfide w/ carbon bushing Electrical: v, Hz,.7A v, /Hz,./.A or volt, Hz -MD-HC -MD-HC 9 -MD-HC Pump head less motor ' ' (w/o plug). GPM. LPM. GPM. LPM NOTE: Although no pump should be operated dry, the -MD-HC models with carbon bushing and ceramic shaft have a run-dry capability of up to eight hours without damage. For more information call..7.79
53 HC SERIES / HP -MD-HC Circulation of highly corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other highly corrosive chemicals and solutions that are compatible with the pump's material of construction / HP open FC motor Glass-filled polyphenylene sulfide magnet housing and volute. specific gravity Viton O-ring Ceramic thrust washers and shaft UR / C-CSA listed (, ) RPM: () 7/ () Capacity:. GPM (7. LPM) Shut Off:.9' (.7 m) Liquid Temperature: F (9. C) Discharge: /" MNPT (.7 mm) Intake: /" FNPT (9 mm) Impeller: Glass-filled polyphenylene sulfide w/ carbon bushing Electrical: v, Hz,.A v, Hz,.A 7 or volt, Hz -MD-HC -MD-HC 97 -MD-HC Pump head less motor ' ' (w/o plug). GPM 7. LPM. GPM 7. LPM NOTE: Although no pump should be operated dry, the -MD-HC models with carbon bushing and ceramic shaft have a run-dry capability of up to eight hours without damage. For more information call..7.79
54 HC SERIES / HP -MD-MT-HC Circulation of highly corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other highly corrosive chemicals and solutions that are compatible with the pump's material of construction / HP open FC motor Glass-filled polyphenylene sulfide magnet housing and volute. specific gravity Viton O-ring Ceramic thrust washers and shaft UR / C-CSA listed (7) RPM: Capacity:. GPM (. LPM) Shut Off:.' (.9 m) Liquid Temperature: F (9. C) Discharge: /" MNPT (.7 mm) Intake: /" MNPT (.7 mm) Impeller: Glass-filled polyphenylene sulfide w/ carbon bushing Electrical: v, /Hz,.A 9 7 -MD-MT-HC 797 -MD-MT-HC Pump head less motor (w/o base) '. GPM. LPM 79 -MD-MT-HC Pump head less motor (w/ base) NOTE: Although no pump should be operated dry, the -MD-MT-HC models with carbon bushing and ceramic shaft have a run-dry capability of up to eight hours without damage. For more information call..7.79
55 HC SERIES / HP TE--MD-HC Circulation of highly corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other highly corrosive chemicals and solutions that are compatible with the pump's material of construction / HP TEFC motor Glass-filled polyphenylene sulfide magnet housing and volute. specific gravity Viton O-ring Ceramic thrust washers and shaft UR / C-CSA listed (, ) RPM: () 7/ () Capacity: 9.7 GPM (.9 LPM) Shut Off:.' (.9 m) Liquid Temperature: F (9. C) Discharge: /" MNPT (.7 mm) Intake: /" FNPT (.7 mm) Impeller: Glass-filled polyphenylene sulfide w/ carbon bushing Electrical: v, Hz,.A v, /Hz,./.A 9 or volt, Hz TE--MD-HC TE--MD-HC 9 TE--MD-HC Pump head less motor ' ' (w/o plug) 9.7 GPM.9 LPM 9.7 GPM.9 LPM NOTE: Although no pump should be operated dry, the TE--MD-HC models with carbon bushing and ceramic shaft have a run-dry capability of up to eight hours without damage. For more information call..7.79
56 HC SERIES / HP -MD-HC Circulation of highly corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other highly corrosive chemicals and solutions that are compatible with the pump's material of construction / HP open FC PSC motor Glass-filled polyphenylene sulfide magnet housing and volute. specific gravity Viton O-ring Ceramic thrust washers and shaft " FNPT (. mm) intake UR / C-CSA listed () RPM: Capacity: GPM ( LPM) Shut Off:.' (7. m) Liquid Temperature: F (9. C) Discharge: /" MNPT (.7 mm) Intake: " FNPT (. mm) Impeller: Glass-filled polyphenylene sulfide w/ carbon bushing Electrical: v, /Hz,.7A 7 volt, Hz -MD-HC 9 -MD-HC Pump head less motor ' GPM LPM NOTE: Although no pump should be operated dry, the -MD-HC model with carbon bushing and ceramic shaft has a run-dry capability of up to eight hours without damage. For more information call..7.79
57 HC SERIES / HP TE--MD-HC Circulation of highly corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other highly corrosive chemicals and solutions that are compatible with the pump's material of construction / HP open TEFC PSC motor Glass-filled polyphenylene sulfide magnet housing and volute. specific gravity Viton O-ring Ceramic thrust washers and shaft UR / C-CSA listed RPM: () 7/ () Capacity: GPM ( LPM) Shut Off:.' (7. m) Liquid Temperature: F (9. C) Discharge: /" MNPT (.7 mm) Intake: " FNPT (. mm) Impeller: Glass-filled polyphenylene sulfide w/ carbon bushing Electrical: v, Hz,.7A v, /Hz,./.7A 7 or volt, Hz TE--MD-HC TE--MD-HC ' ' (w/o plug) GPM LPM GPM LPM NOTE: Although no pump should be operated dry, the TE--MD-HC models with carbon bushing and ceramic shaft have a run-dry capability of up to eight hours without damage. For more information call..7.79
58 HC SERIES / HP -MD-HC Circulation of highly corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other highly corrosive chemicals and solutions that are compatible with the pump's material of construction / HP open FC PSC motor Glass-filled polyphenylene sulfide magnet housing and volute. specific gravity Viton O-ring Ceramic thrust washers and shaft UR / C-CSA listed (, ) RPM: () / () Capacity: 7. GPM (. LPM) Shut Off: 7.' (. m) Liquid Temperature: F (9. C) Discharge: /" MNPT (.7 mm) Intake: " FNPT (. mm) Impeller: Glass-filled polyphenylene sulfide w/ carbon bushing Electrical: v, /Hz, A v, /Hz,.9A 9 or volt, Hz 9 7 ' 7. GPM -MD-HC. LPM -MD-HC 9 -MD-HC Pump head less motor ' (w/o plug) 7. GPM. LPM NOTE: Although no pump should be operated dry, the -MD-HC models with carbon bushing and ceramic shaft have a run-dry capability of up to eight hours without damage. For more information call
59 HC SERIES / HP TE--MD-HC Circulation of highly corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other highly corrosive chemicals and solutions that are compatible with the pump's material of construction / HP TEFC PSC motor Glass-filled polyphenylene sulfide magnet housing and volute. specific gravity Viton O-ring Ceramic thrust washers and shaft UR / C-CSA listed () RPM: / Capacity: GPM (7.7 LPM) Shut Off: 9.' (.9 m) Liquid Temperature: F (9. C) Discharge: /" MNPT (.7 mm) Intake: " FNPT (. mm) Impeller: Glass-filled polyphenylene sulfide w/ carbon bushing Electrical: v, /Hz,./A v, /Hz,./.A or volt, Hz 9 7 ' GPM TE--MD-HC / Cord not installed 7.7 LPM 9 TE--MD-HC Pump head less motor NOTE: Although no pump should be operated dry, the TE--MD-HC model with carbon bushing and ceramic shaft has a run-dry capability of up to eight hours without damage. For more information call..7.79
60 HC SERIES / HP TE-.-MD-HC Circulation of highly corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other highly corrosive chemicals and solutions that are compatible with the pump's material of construction / HP TEFC motor Glass-filled polyphenylene sulfide volute and backplate. specific gravity Viton O-ring Ceramic thrust washers and shaft UR / C-CSA listed () RPM: / Capacity: GPM (. LPM) Shut Off:.' (. m) Liquid Temperature: F (. C) Discharge: /" MNPT (9 mm) Intake: " FNPT (. mm) Impeller: Glass-filled polyphenylene sulfide w/ carbon bushing Electrical: v, /Hz,./A v, /Hz,./.A or volt, Hz TE-.-MD-HC / Not included 9 TE-.-MD-HC Pump head less motor GPM. LPM NOTE: Although no pump should be operated dry, the TE-.-MD-HC model with carbon bushing and ceramic shaft has a run-dry capability of up to eight hours without damage. For more information call
61 HC SERIES / HP TE--MD-HC Circulation of highly corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other highly corrosive chemicals and solutions that are compatible with the pump's material of construction / HP TEFC split phase motor Glass-filled polyphenylene sulfide volute and backplate. specific gravity Viton O-ring Ceramic thrust washers and shaft UR / C-CSA listed () RPM: / Capacity: GPM (. LPM) Shut Off: ' (. m) Liquid Temperature: F (. C) Discharge: /" MNPT (9 mm) Intake: " FNPT (. mm) Impeller: Glass-filled polyphenylene sulfide w/ carbon bushing Electrical: v, /Hz,./9.A v, /Hz,./.7A 9 or volt, Hz TE--MD-HC / Not included 9 TE--MD-HC Pump head less motor GPM. LPM NOTE: Although no pump should be operated dry, the TE--MD-HC model with carbon bushing and ceramic shaft has a run-dry capability of up to eight hours without damage. For more information call..7.79
62 HC SERIES / HP TE-7-MD-HC Circulation of highly corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other highly corrosive chemicals and solutions that are compatible with the pump's material of construction / HP TEFC PSC motor Glass-filled polyphenylene sulfide volute and backplate. specific gravity Viton O-ring Ceramic thrust washers and shaft UR / C-CSA listed (7), UR listed (7) RPM: / Capacity: GPM (. LPM) Shut Off:.9' (7.9 m) Liquid Temperature: F (9. C) Discharge: " MNPT (. mm) Intake: -/" FNPT ( mm) Impeller: Glass-filled polyphenylene sulfide w/ carbon bushing Electrical: v, /Hz,./.A v, /Hz,./.9A Phase: v, /Hz,./.9A v, /Hz,./.A or volt, Hz 9 7 TE-7-MD-HC / Not included 7 TE-7-MD-HC 7 TE-7-MD-HC Pump head less motor / Phase Not included GPM. LPM GPM. LPM NOTE: Although no pump should be operated dry, the TE-7-MD-HC models with carbon bushing and ceramic shaft have a run-dry capability of up to eight hours without damage. For more information call..7.79
63 CK SERIES / HP TE-.-MD-CK Circulation of highly corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other highly corrosive chemicals and solutions that are compatible with the pump's material of construction / HP TEFC split phase motor Carbon-filled Kynar (PVDF) volute and backplate. specific gravity Viton O-ring Ceramic thrust washers and shaft UR / C-CSA listed RPM: / Capacity: GPM (. LPM) Shut Off:.' (. m) Liquid Temperature: F (9. C) Discharge: /" MNPT (9 mm) Intake: " FNPT (. mm) * This pump does NOT have run dry capabilities. Impeller: Carbon-filled Kynar (PVDF) w/ mica-filled Teflon bushing* Electrical: v, /Hz,./.A v, /Hz,./.A TE-.-MD-CK / Not included GPM. LPM or volt, Hz For more information call..7.79
64 CK SERIES / HP TE--MD-CK Circulation of highly corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other highly corrosive chemicals and solutions that are compatible with the pump's material of construction / HP TEFC split phase motor Carbon-filled Kynar (PVDF) volute and backplate. specific gravity Viton O-ring Ceramic thrust washers and shaft UR / C-CSA listed RPM: / Capacity: GPM (. LPM) Shut Off: 9' (.9 m) Liquid Temperature: F (9. C) Discharge: /" MNPT (9 mm) Intake: " FNPT (. mm) Impeller: Carbon-filled Kynar (PVDF) w/ Chemloy bushing Electrical: v, /Hz,./9.A v, /Hz,./.7A TE--MD-CK / Not included GPM. LPM or volt, Hz 9 For more information call..7.79
65 CK SERIES / HP TE--MD-CK Circulation of highly corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other highly corrosive chemicals and solutions that are compatible with the pump's material of construction / HP TEFC split phase motor Carbon-filled Kynar (PVDF) volute and backplate. specific gravity Viton O-ring Ceramic thrust washers and shaft UR / C-CSA listed RPM: / Capacity: GPM (. LPM) Shut Off: 9' (.9 m) Liquid Temperature: F (9. C) Discharge: /" MNPT (9 mm) Intake: " FNPT (. mm) Impeller: Carbon-filled Kynar (PVDF) w/ mica-filled Teflon bushing Electrical: v, /Hz,./9.A v, /Hz,./.7A TE--MD-CK / Not included GPM. LPM or volt, Hz 9 For more information call..7.79
66 CK SERIES / HP TE-7-MD-CK Circulation of highly corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other highly corrosive chemicals and solutions that are compatible with the pump's material of construction / HP TEFC PSC motor Carbon-filled Kynar (PVDF) volute and backplate. specific gravity Viton O-ring Ceramic thrust washers and shaft -/" FNPT ( mm) intake RPM: / Capacity: GPM (. LPM) Shut Off:.' (7. m) Liquid Temperature: F (9. C) Discharge: " MNPT (. mm) Intake: -/" FNPT ( mm) UR / C-CSA listed (7), UR listed (7) Impeller: Carbon-filled Kynar (PVDF) w/ Chemloy bushing Electrical: v, /Hz,./.A v, /Hz,./.9A Phase: v, /Hz,./.9A v, /Hz,./.A 7 TE-7-MD-CK / Not included 7 TE-7-MD-CK 7 TE-7-MD-CK Pump head less motor / Phase Not included GPM. LPM GPM. LPM or volt, Hz 9 For more information call..7.79
67 Peristaltic Pumps Tube Pumps LG- LG- LG- Designed to handle fluids that should not be exposed to pump parts, ideal for moving solutions, such as slurries, harsh chemicals, detergents, sludge, sterile fluids, syrups, and metered solutions. The fluid being pumped comes in contact with tube only. Motors, motor pulleys, tubing and V-belts are not included Additional items needed: -/" (. mm) OD motor pulley for type A or L V-belt for /" (.7 mm) shaft (if using Little Giant base, belt length should be " [7. cm]) Suggested motors: Dayton (stock #K9), GE (stock #XBH), or Marathon (stock #S7D) / HP, NEMA frame, with resilient cradle base 7 RPM rating and thermally protected, with a F ( C) rise A service factor of. A minimum Class A insulation rating Pump speed will be approx. 7 RPM with above specifications Total Gallons per Minute /" I.D. X /" O.D. Tube /" I.D. X /" O.D. Tube /" I.D. X /" O.D. Tube /" I.D. X 7/" O.D. Tube RPM RPM Performance Based On -/" Motor Pulley Item # Model Recommended Tube Sizes (ID x OD) Pump Pulley 7 LG- /" x 7/" or /" x /" 79 LG- /" x 7/" or /" x /" 7 LG- /" x /" or /" x /" 79 LG- /" x /" or /" x /" ". cm ". cm ". cm ". cm For more information call..7.79
08 general Purpose Pumps
070 08 general Purpose Pumps InTRODuCTIOn Ballast Pumps Today s Wakeboard and Ski tow boats need to be able to take on water ballast to modify their wake formation. A development of our tried and tested
More informationMARCH PUMPS CENTRIFUGAL MAGNETIC DRIVE PUMPS
MARCH PUMPS CENTRIFUGAL MAGNETIC DRIVE PUMPS W W W. M A R C H P U M P. C O M MARCH PUMPS Why a magnetic drive pump? A magnetic drive pump is sealless, preventing any leakage that is normally associated
More information07 Oil Change & Diesel Transfer Pumps
64 07 Oil Change & Diesel Transfer Pumps OIL CHANGE PUMPS Porta-Quick The Porta-Quick Portable Oil Changer makes quick, clean and easy oil changes onboard any boat because it uses the vessel s own power
More informationNO SHAFT SEAL, LESS PROBLEMS UP TO 200GPM AND 160 FEET MARCH PUMPS CENTRIFUGAL MAGNETIC DRIVE PUMPS
NO SHAFT SEAL, LESS PROBLEMS UP TO 200GPM AND 160 FEET MARCH PUMPS CENTRIFUGAL MAGNETIC DRIVE PUMPS MARCH PUMPS Why A ic Drive Pump A magnetic drive pump is sealless, preventing any leakage that is normally
More informationMAX FLUID TEMPERATURE
Operation is similar to standard centrifugal pumps, except the impeller is driven with a magnetic coupling, eliminating the need for a shaft seal. Magnetic drive pumps must be used where flooded suction
More informationWastewater pumps Condensate pumps S u b m e r s i b l e p u m p s M a g n e t i c d r i v e p u m p s Corporate
Corporate Wastewater Pumps Condensate pumps Submersible pumps Magnetic drive pumps A great idea, A great pump. Little Giant Pump Company s origins date back to 1941, when an idea by a plumber named Doc
More information07 Oil Change & Diesel Transfer Pumps
064 07 Oil Change & Diesel Transfer Pumps OIL CHAngE PuMPS Porta-Quick The Porta-Quick Portable Oil Changer makes quick, clean and easy oil changes onboard any boat, because it uses the vessel s own power
More informationKoolAir PM500. Fully Submersible. Marine Coolant Pump. Pump Features:
KoolAir PM500 Marine Coolant Pump Fully Submersible Pump Features: n Pumps 500 gallons/hr n Run Dry and Thermal Overload Protection n In a Run Dry scenario, the pump will shut down. Simply let it cool
More informationModel and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS
Model 31801 and 31800 Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS INDUSTRIAL DIAPHRAGM PUMPS FEATURES Run Dry Ability Self-Priming Thermal Overload Protected Motor Easy Installation Low Amp Draw Compact
More informationGeneral Purpose Pumps - Introduction
6 www.jabsco.com Introduction It probably goes without saying that many Jabsco pumps have more than one possible application. Sometimes it is a simple matter of installing the standard product in the different
More informationBULLETIN 350A. Sethco FLOWS TO 225 GPM. Seal-less, Self Priming, Magnetic Drive Centrifugal Pumps. For Corrosive Liquid and Chemical Transfer
BULLETIN 350A FLOWS TO 225 GPM Sethco Seal-less, Self Priming, Magnetic Drive Centrifugal Pumps For Corrosive Liquid and Chemical Transfer SETHCO CORROSION RESISTANT SELF PRIMING MAGNETIC-DRIVE, SEAL-LESS
More informationCommitment To Quality
Commitment To Quality Franklin Electric is committed to provide customers with defect free products through our program of continuous improvement. Quality shall, in every case, take precedence over quantity.
More informationBULLETIN 340B. Sethco FLOWS TO 275 GPM. Seal-less, End Suction Magnetic Drive Centrifugal Pumps. For Corrosive Liquid and Chemical Transfer
BULLETIN 34B FLOWS TO 275 GPM Sethco Seal-less, End Suction Magnetic Drive Centrifugal Pumps For Corrosive Liquid and Chemical Transfer SETHCO END SUCTION CORROSION RESISTANT MAGNETIC DRIVE, SEAL-LESS
More informationMYERS 3MW VERTICAL DISCHARGE WASTEWATER PUMPS. Sewage, high-capacity sump, effluent
The Myers heavy-duty series pumps are designed for residential raw sewage and light commercial applications. The non-clogging two-vane impeller delivers high-efficiency pumping and easily handles trashy
More informationAstral Pumps 17-1 SEN1807 N/A SEN SEN1815 N/A
Astral Pumps Limited supply of 1 HP (1810) C/C price of 250.00 each Reference List Price Standard Carton Carton Weight (lbs.) Carton Volume (ft^3) SEN1807 N/A 1 27 2.6 SEN1810 390.00 1 28 2.6 SEN1815 N/A
More informationSUBMERSIBLE PUMPS DRAINER SUMP/EFFLUENT
SUBMERSIBLE PUMPS DRAINER SUMP/EFFLUENT LEESON Canada features products by well known manufacturer Berkeley which includes the Toran and Simer brand names. SUBMERSIBLE UTILITY PUMPS GEYSER II 1/6 HP 1/6
More informationBULLETIN 340B. Sethco FLOWS TO 275 GPM. Seal-less, End Suction Magnetic Drive Centrifugal Pumps. For Corrosive Liquid and Chemical Transfer
BULLETIN 340B FLOWS TO 275 GPM Sethco Seal-less, End Suction Magnetic Drive Centrifugal Pumps For Corrosive Liquid and Chemical Transfer SETHCO END SUCTION CORROSION RESISTANT MAGNETIC DRIVE, SEAL-LESS
More informationINDUSTRIAL PRODUCTS 2010 CATALOG
has a new name SHURflo Industrial INDUSTRIAL PRODUCTS 2010 CATALOG Pumps: Centrifugal Gear Roller Flexible Impeller Effective: 1/1/2010 has a new name SHURflo Industrial The SHURflo product line is a world
More informationJet Pumps. Convertible Shallow Well. 6/13 Rev (3/14)
Jet Pumps Convertible Shallow Well 6/13 Rev (3/14) Table of Contents Page General Information...2-4 Nema J Motor Pumps 8100 Series - Shallow Well... 5 8200 Series - Convertible...6-7 Square Flange Motor
More informationDPS. The SSV Dual Pump System
DPS The SSV Dual Pump System A Full Range of Product Features The DPS series of 36L stainless steel vertical multi-stage pumps from G&L has been designed to provide reliable high pressure boosting to serve
More informationSubmersible/Inline Products WasteWater Products Water Garden Products Pool Products Aquarium Pumps Export Products HVAC Products Industrial Products
General Information............................ 1 WasteWater Products Transfer Pumps and Parts........................ 3 Water Wizard Utility/Sump Pumps............... 3 Sump Pumps..................................
More informationKW Submersible, Single-Vane Impeller
Sewage Pumps KW Submersible, Single-Vane Impeller Performance Curve Total Head (FT) Up to 2 Solids-Handling Heavy-Duty, Silicon Carbide Seals Stainless Steel Keyed Shaft Flows to 325 GPM / Heads to 95
More informationMarine Pumps & Accessories
Marine Pumps & Accessories Company Profile & Contents FLOJET Corporation is the leading manufacturer of marine pumps and accessories. With over 20 years experience in pump design and manufacturing, FLOJET
More informationC A T A L O G MARCH PUMPS
C A T A L O G MARCH PUMPS C H E M I C A L O E M I N D U S T R I A L H Y D R O N I C S O L A R P A G E 2 MARCH SEAL- LESS MAGNETIC DRIVE PUMPS The ultimate in reliable performance for chemical, OEM, indtrial,
More informationProMinent Beta Solenoid Diaphragm Metering Pumps
Overview: Beta Ideal for basic chemical feed applications (see page 127 for spare parts, page 138 for accessory kits and page 138 for control cables) ProMinent pk_1_004_1 Capacity range 0.2-8.4 gph, 232-29
More informationHusky 515 / 716 Air-Operated Diaphragm Pumps
First choice when quality counts. Husky 515 / 716 Air-Operated Diaphragm Pumps 515 1/2 in. non-metallic pumps in acetal, polypropylene, and kynar 716 3/4 in. metal pumps in SST, aluminum No seals to leak
More informationSP SERIES SELF-PRIMING MAG DRIVE
SP SERIES SELF-PRIMING MAG DRIVE spend less time waiting. and more time pumping. year Big on power yet short on energy consumption, the SP Series from Finish Thompson is one of the most versatile and economical
More informationfile:///users/revspencer/documents/fm Workon/Website-on-Local 2/marinepumps.html Marine Pumps - Continuous duty (Español)
1 of 5 12/30/13 11:23 AM Marine Pumps - Continuous duty (Español) Excellence in Marine Engineering Since 1995! We pass along our OEM buying power to you, offering you the finest pumps available at "Factory
More informationFuel Transfer Pumps DC Aluminum Gear Fuel Pump with Auto Nozzle
Pumps 110300-2 DC Aluminum Gear Fuel Pump with Auto Nozzle 110300-2 12-Volt DC - Rotary Gear. Explosion Proof Motor. Up to 18 GPM (69 LPM) 12 ft. (3.7m) x 1 in. Hose 137100-01 EZ-8 DC Fuel Pump 137100-01
More informationTECHNICAL BROCHURE B36/ /3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS
TECHNICAL BROCHURE B36/3742 3642/3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS FEATURES Compact Design: Close coupled, space saving design provides easy installation. Flexible couplings and bedplates
More informationInformation Sheet Polyethylene Tank Assemblies
Information Sheet Polyethylene Tank Assemblies No. 27421 10 Gallon Tank Assembly Ultraviolet resistant, yellow polyethylene tank. Molded recesses for mounting of any LMI Series A, J, or P pump. Convenient
More informationElectric Submersible Pumps
Electric Submersible Pumps Versatile pumps with a wide variety of applications Construction Starts Here www.multiquip.com Electric Submersible Pumps Bolt-on discharge port allows easy replacement Cast
More informationOPERATOR S MANUAL C INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:
OPERATOR S MANUAL 650719-C INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 8-11-03 REVISED: 12-3-10 (REV. 08) 2" DIAPHRAGM PUMP U.L. LISTED, 1:1 RATIO, METALLIC READ THIS MANUAL CAREFULLY BEFORE
More information5GB, 7GB, 10GB, 18GB, 25GB, 33GB
B-33GB GB, 7GB, GB, 18GB, 2GB, 33GB High Pressure Multi-Stage Booster Pump FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction: Standard
More informationPump Specifications FL100 Series Submersible Effluent Pump
Head (Feet) Head (Meters) Pump Specifications FL100 Series Submersible Effluent Pump Flow (Liters Per Minute) 100 0 38 76 114 151 189 227 265 303 341 379 416 30 90 27 80 24 70 21 60 18 50 15 40 12 30 9
More informationSPECIFICATIONS EFFLUENT/SUMP SIMPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347 Louisville, KY 40256-0347 SHIP TO: 3649
More informationTECHNICAL BROCHURE B36/3742 R2 3642/3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS
TECHNICAL BROCHURE B36/3742 R2 3642/3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS FEATURES Compact Design: Close coupled, space saving design provides easy installation. Flexible couplings and
More informationLUBRICATION & FLUID HANDLING ACCESSORIES. Heavy duty knurled steel barrel with large threads for easy loading.
hand grease guns Lever type The tough high pressure cast iron head makes Pro-Master Grease Guns unique in comparison to common pot metal or other die cast heads with a head burst pressure of 17,000 PSI
More informationSeries P Series P. Penguin Vertical Pump
Features: Choice of CPVC, PVDF, or Polypropylene Sealless Runs Dry Without Damage Self-Priming When Immersed No Metal Contact Chemical Resistant Extended Pump Lengths Available (See Bulletin 1) Recommended
More informationMICROPUMP MAG-DRIVE GEAR PUMPS
MAG-DRIVE GEAR PUMPS REVISION # 1 DATE: 6-6-6 WETTED MATERIALS Pump housings: 316 stainless steel. Gears: PEEK. Gear shafts: 316 stainless steel. Gear shaft bearings: PEEK. Driven magnet: Totally encapsulated
More informationCARBONATORS & WATER BOOSTERS
McCann Carbonators are the industry standard, and have a time-tested, reliable design. These carbonators feature a two-piece design with an encapsulated electronics package. This design allows for service
More informationREPAIR SEALS AND OPTIONS
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationSKV40. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 2" Solids: 2" GPM: TDH:
Performance RPM: 1550 Discharge: 2" Solids: 2" Wholesale Products Page: 6730-1 Section: Performance 8 25 7 20 HEAD-METERS 5 4 HEAD-FEET 15 4/10 HP 3 10 2 0 0 20 40 60 80 Capacity-U.S. G.P.M. Liters/Second
More informationSPECIFICATIONS EFFLUENT/SUMP DUPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347 Louisville, KY 40256-0347 SHIP TO: 3649
More informationE8 Mini-Matic 3/8" Bolted Plastic Pumps Operating Instructions
E8 Mini-Matic 3/8" Bolted Plastic Pumps Operating Instructions Polypropylene SAFETY WARNINGS Read these instructions completely before installation and start-up. It is the responsibility of the purchaser
More informationOPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG25 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev.
OPERATION MANUAL NTG25 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models 316 S.S. Models A JDA Global Company 1/14 rev. 3 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to
More informationModels Series Series
PumpAgents.com - Click here for Pricing/Ordering Models 11860-Series 11870-Series SELF-PRIMING PUMPS ELECTRO-MAGNETIC CLUTCH UNIT FEATURES Body: Impeller: Shaft: Seal: Ports: Bearings: Weight: Bronze Nitrile
More informationOPERATION MANUAL. DUCTILE Models NT100 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 5/13 rev.2
OPERATION MANUAL NT100 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS DUCTILE Models A JDA Global Company 5/13 rev.2 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to 93.3 C 0 F to 200
More informationSPUR GEAR PRODUCT LINE: CAST IRON PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE. Section 1451 Page 1451.
Page 1451.1 TABLE OF CONTENTS Features & Benefits...2 Typical Applications...2 Port Location Options...2 Model Number Key...3 Standard Materials of Construction...3 Cutaway View & Pump Features...4 Component
More informationHigh Capacity Centrifugal & Sprinkler Pumps
High Capacity Centrifugal & Sprinkler Pumps FW0724 1016 Supersedes 0212 Stainless steel or cast iron construction Stainless steel impellers Discharge rotates in 90 increments on some models Pressures to
More informationFLEX-PRO TM PERISTALTIC PUMPS
FLEX-PRO TM PERISTALTIC PUMPS Applications Chemical Wastewater treatment Chlorination Pulp & Paper Slurries Printing inks Oil based fluids Gaseous fluids Shear sensitive fluids Caustics Chemical Slurries
More informationModels: D-12, G-12. Parts Manual D D WANNER ENGINEERING, INC.
Parts Manual D12-991-2402D Models: D-12, G-12 IMPORTANT Record your pump model number and serial number here for easy reference: Model No. Serial No. Date of Purchase When ordering parts or making inquiries
More informationHIGH CAPACITY CENTRIFUGAL & SPRINKLER PUMPS
HIGH CAPACITY CENTRIFUGAL & SPRINKLER PUMPS FW0724 0707 Supersedes 1005 Straight Centrifugal Pumps Electric Motors Heavy Duty Straight Centrifugal Pumps High Head Straight Centrifugal Pumps Stainless Steel
More informationD51 D61 D71 D91 Series
MTH PUMPS D51 D61 D71 D91 Series Page D-1 Capacities to 24 GPM Heads to 36 Feet Horizontal Close Coupled Close-coupled centrifugal pumps from MTH provide economical performance up to 24 GPM applications
More informationNEW! BOOSTER PUMPS. HBP/HBPS series 4" horizontal booster pumps. booster pumps
HBP/HBPS series 4" horizontal The HBP/HBPS Series Booster Pumps are the most durable available. The patented SignaSeal floating impeller design minimizes thrust loads, allowing for continuous operation
More information8000 Series Diaphragm Pump Automatic-Demand Pumps 12 VDC
SHURflo Pumps SHURflo offers a complete line of pumps and accessories to meet the needs of homeowners, hobbyists, green industry professionals and commercial growers alike. From our high pressure spray
More informationBulk Chemical Pumps. Model 1100 Series Pumps. TOTE PUMP & GO KIT The Most Versatile, Dependable Liquid Transfer Pump You Will Ever Own PUMPS
BULK CHEMICAL 0 Bulk Chemical Pumps Model 00 Series Pumps New from SHURflo, the rugged 00 Series General Utility Transfer Pump is a highly-efficient, VDC, Positive-displacement pump. This Self-Priming,
More informationThis catalog contains the following geothermal accessory products and specification guides:
f o r r e s i d e n t i a l s y s t e m s Geothermal systems offer an effective way to cut utility costs while ensuring comfort. Heat Controller s line includes two stage and single stage geothermal heat
More informationNDP-50 Specifications
NDP-50 Specifications Port Dimensions Intake & discharge connection: (164 GPM Max.) Polypropylene (PPG) 2" ANSI B16.5 #150 Kynar (PVDF) 2" ANSI B16.5 #150 Aluminum (ADC-12) 2" ANSI B16.5 #150 (with tapped
More informationSHURflo Self-Priming Close-Coupled Centrifugal Pumps In 316 Stainless Steel, Bronze and Cast Iron
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationfranklinwater.com 50 Hz VR SERIES Vertical Multi-Stage Pumps
franklinwater.com 5 Hz VR SERIES Vertical Multi-Stage Pumps 5 HZ VR SERIES VERTICAL MULTI-STAGE PUMPS Features 2 Applications 2 Pump Specifications Counter-Flange Kits Motor Specifications 4 Ordering
More informationMYERS 4VCDP. 4" Solids Handling
MYERS 4VCDP Standard Submersible Dry Pit 4" Solids Handling Wastewater Pumps WWW.FEMYERS.COM TECHNICAL INFORMATION 2 SMOOTH OPERATION The 4VCDP submersible dry pit wastewater pumps are a heavy-duty 4"
More information1-1/2" DIAPHRAGM PUMP 1:1 Ratio (metallic) with Cone Checks
OPERATOR S MANUAL 670053-X-X INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 3-24-06 REVISED: 5-11-15 (REV. F) 1-1/2" DIAPHRAGM PUMP 1:1 Ratio (metallic) with Cone Checks READ THIS MANUAL CAREFULLY
More informationAgriculture Pumps and Accessories
Agriculture Pumps and Accessories To access our 24 Hour Technical Data Assistance Via Fax, Call (8) 337-483 For DFAX #1 series and (8) 297-394 for DFAX #2 series Simply enter the Docufax number (under
More informationREPAIR SEALS AND OPTIONS
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationPENGUIN. Magnetic Drive Pump. Series M INTRODUCTION RECOMMENDATIONS ELECTRICAL PLUMBING. Installation & Maintenance
PENGUIN Installation & Maintenance Magnetic Drive Pump Series M MODELS M-1/14 M-1/8 M-1/4 M-1/3 M-1/2 M-3/4 M-2 M-3 M-10 MATERIALS B - Polypropylene C - PVDF (Kynar) S - 316 Stainless Steel INTRODUCTION
More informationEN. 850 Filtrate Pumps. Technical Specification Pages
850 17.01.EN 850 Filtrate Pumps Technical Specification Pages 850 Series Filtrate Pump 850 17.01.EN This page left intentionally blank. 1.0 Overview. The 850 is Carver s filtrate pump line designed for
More informationBooster Pumps. Non-Submersible Pumps. BT4 Series. Cast Iron Features: Applications:
BT4 Series CSA ENC 3 COF CSA 3 C US CSA 18 UL 8 Applications: Boosting water pressure from either city mains or private water systems. Pressure washing buildings and floors. Poultry houses. Spray cooling
More informationNDP-25 Specifications
NDP-25 Specifications Port Dimensions (46.2 GPM Max.) Intake & discharge connection: Polypropylene (PPG) Kynar (PVDF) Aluminum (ADC-12) Stainless Steel (316) Cast Iron Air inlet (incl. ball valve): Air
More informationSERIES: WT SELF-PRIMING CENTRIFUGAL PUMPS
40 Third Street Piqua, Ohio 45356-0603 www.pumpagents.com PumpAgents.com - Click here for Pricing/Ordering SERIES: WT SECTION 4C PAGE ISSUED /04 REPLACES /03 SELF-PRIMING CENTRIFUGAL PUMPS For Water and
More informationPump Specifications LE100-Series 1HP Submersible Sewage Pump
Pump Specifications LE100-Series 1HP Submersible Sewage Pump LE100-P1 R8/5/2014 Copyright 2014 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice. LE100-Series Dimensional
More informationKG(X)3. Grinder Pumps. 3HP High Flow Grinder Pump (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve. Total Head (FT) Capacity (GPM)
Grinder Pumps 3HP High Flow Grinder Pump (Class 1, Div. 1, Groups C & D Hazardous Location) The KEEN PUMP series centrifugal grinder pumps easily handle residential, commercial or industrial sanitary waste,
More informationHydracel High Pressure Pump
Hydracel High Pressure Pump Mfg: Hydracell Model: D10 SL SE SHEHC Stock No. HDPH038.5a Serial No. 99260 Hydracell High pressure Pump. Model D10 SL SE SHEHC, S/N 99260. Inlet (1) 1-1/2 in., Outlet (1) 1
More informationTECHNICAL BROCHURE BSPMSPH R1 SOLD SEPARATELY OR BUILT IN. PrimeLine SP SPM & SPH SERIES
TECHNICAL BROCHURE BSPMSPH R1 SOLD SEPARATELY OR BUILT IN PrimeLine SP SPM & SPH SERIES FEATURES Self Priming Design: Features a replaceable check valve which acts to retain sufficient liquid in the casing
More informationModels: G-25, H-25 With Non-Metallic Pump Head
Parts Manual G25-991-2403B Models: G-25, H-25 With Non-Metallic Pump Head WANNER ENGINEERING, INC. W0193B 1204 Chestnut Avenue, Minneapolis, MN 55403 TEL: (12) 332-581 FAX: (12) 332-937 TOLL-FREE FAX [US
More informationPump Specifications. LE50 Series ½ HP Submersible Sewage Pump
Pump Specifications LE50 Series ½ HP Submersible Sewage Pump LE50_P1 R11/16/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice. LE50-Series Dimensional
More informationOPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG40 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14, Rev.
OPERATION MANUAL NTG40 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models 316 S.S. Models A JDA Global Company 1/14, Rev. 3 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to
More information05 Water Pressure Systems INTRODUCTION
52 05 Water Pressure Systems INTRODUCTION Pressure Controlled Diaphragm Pumps Pressure controlled diaphragm pumps provide boat owners with a fresh water system that is as easy to use as their domestic
More informationGoulds 3181 High-temperature/Pressure Paper Stock/ Process Pumps
High-temperature/Pressure Paper Stock/ Process Pumps Designed to Handle High Temperature and High Pressure Services of the Pulp & Paper Industries Capacities to 13,000 GPM (3000 m 3 /h) Heads to 410 feet
More informationE1 Bolted Pump Specifications End Ported Dimensions
OPERATING INSTRUCTIONS 1" Elima-Matic Bolted Pump Characteristics Adjustable Flow Rate Rugged Diaphragms. 0 to 8.5 m 3 /hr (0-37 gpm) Teflon Diaphragms...0 to 6.8 m 3 /hr (0-30 gpm) Pump Connections Suction....1
More informationITT. Goulds Pumps. 5GB, 7GB, 10GB, 18GB, 25GB, 33GB High Pressure Multi-Stage Booster Pump. Engineered for life. Residential Water Systems FEATURES
Goulds Pumps GB, 7GB, 1GB, 18GB, 2GB, 33GB High Pressure Multi-Stage Booster Pump FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction:
More informationModel: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS
OWNER S MANUAL Model: PFUPPP2528251M10 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump ISP No: PFUPPP25-8/01/15 General Safety Information Before installation, read the following instructions carefully.
More informationS Series PACER Pumps. PACER Pumps 5/91 Page 1 of 5. Dultmeier Sales for Omaha, NE or for Davenport, IA
PACER Pumps 5/91 Page 1 of 5 Item# Part No. Description Qty. 4 58-0721 NUT, BODY, Plated steel, 1/4-20 Hex... 10 58-0721 10 NUT, BODY, Stainless steel, 1/4-20 Hex... 10 6 58-0703 30 Bracket, polyester...
More informationAGRICULTURE PRODUCTS CATALOG
HYPRO SHURflo AGRICULTURE PRODUCTS CATALOG Pumps, Mini-Bulk Transfer Systems & Accessories WWW.HYPROPUMPS.COM SHURflo offers a complete line of pumps and accessories to meet the needs of homeowners, hobbyists,
More information1-1/2 DIAPHRAGM PUMP 1:1 RATIO (METALLIC)
OPERATOR S MANUAL INCLUDING: OPERATION, INSTALLATION & MAINTENANCE 1-1/2 DIAPHRAGM PUMP 1:1 RATIO (METALLIC) 66615X-X-C RELEASED: 5-31-88 REVISED: 1-2-07 (REV. X) READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
More informationPump Specifications FL150 Series Submersible Effluent Pump
Pump Specifications FL150 Series Submersible Effluent Pump FL150_P1 R3/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice. FL150-Series Dimensional
More informationTechnical Data 5430 M & W SUBMERSIBLE SOLIDS HANDLING PUMPS
Technical Data 5430 M & W SUBMERSIBLE SOLIDS HANDLING PUMPS Wet End Rotation Volute Nozzles Impeller Wear Rings Shaft Bearing Frame Bearing Radial/Thrust Lubrication Seal Motor Lifting Bail Volute Discharge
More informationPump Specifications LE70-Series 3/4 HP Submersible Sewage Pump
Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump LE70-P1 R9/3/2013 Copyright 2013 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice. LE70-Series Dimensional
More informationHIGH VELOCITY PUMP PUMP END
HIGH VELOCITY PUMP USFP pumps are designed for firefighting and high volume water supply in industrial, oil and gas, nuclear, municipal, and marine applications. The USFP High Velocity Pump is designed
More informationHEAVY DUTY FLAP VALVE PUMPS For Fluids Containing up to Line Size Solids
HEAVY DUTY FLAP VALVE PUMPS For Fluids Containing up to Line Size Solids A WARREN RUPP, INC. BRAND SANDPIPERPUMP.COM KEY ADVANTAGES OF SANDPIPER FLAP VALVE PUMPS AN IDEAL SOLUTION FOR ABRASIVE SLURRIES,
More informationTECHNICAL BROCHURE B5-33GB R4 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP
TECHNICAL BROCHURE B-33GB R4 GB, 7GB, GB, 1GB, 2GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. applications. O-Ring Casing
More informationPump Specifications LE70-Series 3/4 HP Submersible Sewage Pump
Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump LE70-P1 R3/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice. LE70-Series Dimensional
More informationElectric Fuel Pump FPM
INSTRUCTION MANUAL Electric Fuel Pump FPM S1590, Rev B LISTED MOTOR FPM-12, FPM-24, FPM-115, FPM-220 Congratulations on purchase of this World Class Electric Fuel Pump! Elbow This is an Electric Fuel Pump.
More informationSeries 4XSHM 18 Frame Driver 3" Spherical Solids Handling
Series 4XSHM 18 Frame Driver Specifications: DISCHARGE... 4, 125 lb. Horizontal Flange Slotted to accomodate 100mm ISO Flanges LIQUID TEMPERATURE... 104 F (40 C) Continuous VOLUTE... Cast Iron ASTM A-48,
More informationKS / SKS Vertical Split Coupled Inline Pumps
Water Circulation Pumps & Circulators KS / SKS Vertical Split Coupled Inline Pumps Taco Vertical Split Coupled inline pumps set a new standard in service and maintenance. Now available with SelfSensing
More informationXFL70 FLOW RATE (LPM) Flow Rate (GPM)
Pump Specifications XFL70 Series ¾ HP Submersible Effluent Pump For Hazardous Locations Class 1, Division 1 Groups C & D Class 1, Zone 1 and Groups IIA & IIB 50 XFL70 FLOW RATE (LPM) 0 50 100 150 200 250
More informationGR NDER PUMPS. Technical Catalog
Technical Catalog GR NDER PUMPS U.S.A. 505 Woodland Rd., Mt. Pocono, PA 18344 Phone: (570) 851-0075 Fax: (570) 216-4570 www.grinderpumpsusa.com sales@grinderpumpsusa.com GRINDER PUMPS GPU2-21 1½ HP Grinder
More informationPERMANENT MAGNETIC AND RARE EARTH
COOLANT CLEANERS PERMANENT MAGNETIC AND RARE EARTH Smooth-faced and extended-pole Coolant Cleaners extend the life of cutting tools, grinding wheels, pumps and coolant fluids. FEATURES & Benefits Cleaner
More informationWebster S-Series Vertical Seal-Less Immersible Pumps. Rugged, Non-metallic Chemical Duty Pumps Against a Closed Valve
Webster S-Series Vertical Seal-Less Immersible Pumps Rugged, Non-metallic Chemical Duty Pumps Against a Closed Valve Reduce Unscheduled Downtime The S-Series vertical pump is the pump to choose when unscheduled
More information6 Submersible Motors Hi-Temp 90
Applications These motors are built for dependable operation in 6 diameter or larger water wells, in applications with higher temperature, high thrust or low flow. Basic Features Able to operate in water
More information