EVA Series Powered Air-Purifying Respirator Blower Assembly User Manual

Size: px
Start display at page:

Download "EVA Series Powered Air-Purifying Respirator Blower Assembly User Manual"

Transcription

1 EVA Series Powered Air-Purifying Respirator Blower Assembly User Manual EVA1 - Powered Air-Purifying Respirator (for use with Loose-Fitting Headtops) US-NIOSH EUROPE-EN Powered Air-Purifying Respirator with High Efficiency (HE) Filters - Approval No. TC-21C-0836 (PAPRFC3) Powered Air-Purifying Respirator with OV-AG-HE Filter Cartridges for organic vapors, chlorine, hydrogen chloride, sulfur dioxide, chlorine dioxide, hydrogen fluoride and particulates Approval No. TC-23C-2510 (PAPRFC4) Powered Air-Purifying Respirator with AM-FM-MA-AG-HE Filter Cartridges for ammonia, formaldehyde, methylamine, chlorine, hydrogen chloride, sulfur dioxide, chlorine dioxide, hydrogen fluoride and particulates Approval No. TC-23C-2886 (PAPRFC5) 0194 EN TH3 20TIC, 20SIC, RT3, RT4, 20LFL, 20LFM, 20LF2L, 20LF2M, 20LF2S EN TH2 20TICH, 20SICH, 20SICVH INSPEC 56 Leslie Hough Way Salford Greater Manchester M6 6AJ United Kingdom Cautions and Limitations A. Not for use in atmospheres containing less than 19.5% oxygen. B. Not for use in atmospheres immediately dangerous to life or health. C. Do not exceed maximum use concentrations established by regulatory standards. F. Do not use respirator if airflow is less than four cfm (115 lpm) for tight fitting face pieces or six cfm (170 lpm) for hoods and/or helmets. H. Follow established cartridge and canister change schedules or observe ESLI to ensure that cartridges and canisters are replaced before breakthrough. I. Contains electrical parts that may cause an ignition in flammable or explosive atmospheres. J. Failure to properly use and maintain this product could result in injury or death. K. The Occupational Safety and Health Administration regulations require gas-proof goggles to be worn with this respirator when used against formaldehyde. L. Follow the manufacturer s user instructions for changing cartridges and/or filters. M. All approved respirators shall be selected, fitted, used and maintained in accordance with MSHA, OSHA and other applicable regulations. N. Never substitute, modify, add or omit parts. Use only exact Bullard replacement parts in the configuration as specified by the manufacturer. O. Refer to User s Instructions and/or maintenance manuals for information on use and maintenance of these respirators. P. NIOSH does not evaluate respirators for use as surgical masks. * At very high work rates, the pressure in the device may become negative at peak inhalation flow. Table of Contents Warnings, Cautions and Limitations... 1 Principle of Operation... 2 Battery Pack... 2 Pre-Operational Inspection... 3 Mounting the Breathing Tube... 3 Checking Air Flow... 4 Air-Purifying Elements... 4 Mounting and Replacing Filter/Cartridges... 5 Donning the Blower... 5 WARNING Use strictly in accordance with instructions, labels and limitations pertaining to the EVA Series respirator. 1. The EVA Series respirator does not supply oxygen. Use only in adequately ventilated areas containing at least 19.5% oxygen. 2. Do not use when concentrations of contaminants are immediately dangerous to life or health (IDLH). This term is defined in 29CFR (b). 3. Do not use these respirators for respiratory protection during abrasive blasting or clean up. 4. Do not use in circumstances where the airborne concentration level of contaminant exceeds maximum use concentration for this type of respirator as established by regulatory standards. 5. Leave area immediately if: Breathing becomes difficult Dizziness or other distress occurs You taste or smell the contaminant Unit becomes damaged Battery alarm activates Low Flow alarm activates 6. This apparatus must not be worn with the blower unit switched off. If the blower is switched off, a rapid build-up of carbon dioxide and depletion of oxygen may occur, which could result in death or serious injury. 7. Never alter or modify this respirator. Use only Bullard NIOSH-approved EVA Series components and replacement parts for this respirator. 8. This device is not immune to highly powered RFI/EMI emissions. Failure to follow these warnings could result in death or serious injury. CC20 Series Hood Use RT Series Hood Use... 6 Loose-Fitting Facepiece Use... 6 Low Battery Alarm... 7 Troubleshooting... 8 NIOSH Approval Label... 9 Cleaning and Storage... 10

2 Principle of Operation / Battery Pack 2 EVA Series - Principle of Operation The EVA Series Powered Air-Purifying Respirator (PAPR) System is configured in six parts: 1. The blower and belt assembly: EVA1 Blower Unit EVABELT1 Comfort/Decon Belt PA1AFI Air Flow Indicator (sold separately) 2. The battery pack (Part No. EVABAT1). One fully charged pack will power the blower for approximately four to ten hours depending upon factors such as speed, cartridge selected and cartridge loading. 3. The breathing tube, which is available in two different types and three lengths: PAHT Powered Air Hood Breathing Tube Assembly (standard length) PAHTXS Powered Air Hood Breathing Tube Assembly (short length) PAHTXL Powered Air Hood Breathing Tube Assembly (long length) PA1BT Hood breathing tube assembly with clamp (standard length) PA1BTXS Hood breathing tube assembly with clamp (short length) PA1BTXL Hood breathing tube assembly with clamp (long length) PA20LFBT Loose fitting facepiece breathing tube assembly (standard length) PA20LFBTXS Loose fitting facepiece breathing tube assembly (short length) PA20LFBTXL Loose fitting facepiece breathing tube assembly (long length) 4. The High Efficiency Particulate Absolute (HEPA) filter or chemical filter cartridge. 5. The hood with headband suspension (except for the RT Series) and/or hard hat, or loose fitting facepiece. The following hood models may be used with the EVA Series blower unit: GRH/GRHT Grinding hood with inner bib RT1/RT1T Hood with long inner and outer bib (NIOSH approved for use without a headband suspension) RT2/RT2T Hood with long inner and outer bib (NIOSH approved for use without a headband suspension) RT3/RT3T Hood with long inner and outer bib (NIOSH approved for use without a headband suspension) RT4/RT4T Hood with long inner and outer bib (NIOSH approved for use without a headband suspension) 20TJ/20TJT Hood 20TIC/20TICT Hood with inner bib 20TICH/20TICHT Hood for use with Bullard hard hat 20TICS/20TICST Hood with taped and sealed seams 20SIC/20SICT Hood with taped and sealed seams 20SICV/20SICVT Hood with taped and sealed seams and PVC lens 20SICH/20SICHT Hood with taped and sealed seams for use with Bullard hard hat 20SICVH/20SICVHT Hood with taped and sealed seams and PVC lens for use with Bullard hard hat 20TPC/20TPCT Hood with solvent resistant lens and inner bib 20TP/20TPT Hood with solvent resistant lens 20LFM Loose fitting facepiece, medium size 20LFL Loose fitting facepiece, large size 20LF2M Loose fitting facepiece (narrow profile), medium size 20LF2L Loose fitting facepiece (narrow profile), large size 20LF2S Loose fitting facepiece (narrow profile), small size 6. The Battery Charger: EVASMC Quick charger (single port) EVAGC Gang charger (six port) The blower unit draws in ambient air through the cartridges. The purified air is blown into the wearer s hood through the breathing tube. A flow indicator is provided to check that there is an adequate volume of air available to the wearer prior to use. The system is designed to operate at a minimum air flow of approximately seven cubic feet of air per minute (210 liters per minute) in the hood under normal use on the standard speed setting, and eight and one-half cubic feet of air per minute (241 liters per minute) in the hood under normal use on the high speed setting. A feedback loop from the Mass Flow Sensor to the impellor continually monitors and adjusts the air flow to keep it constant at the design set point. The units are designed for use at temperatures from 23ºF to 129ºF (-5ºC to 55ºC). A high temperature alarm will sound at 50ºC (122ºF). The battery pack mounts in a compartment on the back of the blower. A fully charged battery pack will power the blower for approximately four to ten hours depending upon factors such as speed selected, cartridge selected, and filter/cartridge loading. The EVA Series Blower is equipped with two alarms: A 77 db continuous alarm will sound when the air flow falls below approximately 185 lpm and a 77db intermittent chirp alarm will activate to indicate that the battery has approximately 15 minutes of remaining capacity. Type C Airline Respirators CC20 Series (TC-19C-154), RT Series (TC-19C-412), GRH Series (TC-19C-412) Most of the same headpieces approved for use with the CC20, RT, and GR50 Series of supplied air respirators (SAR) are also approved for use with the EVA Series of powered air-purifying respirators. CC20, RT and GR50 Series respirators provide a high level of respiratory protection and user comfort over long work periods, in a wide variety of hazardous environments. The CC20, RT and GR50 SAR air flow control devices and other components are described in the CC20, RT and GR50 Series User Instructions. Battery Pack One fully charged battery pack will power the blower for approximately four to eight hours depending upon factors such as speed selected, cartridge selected and filer/ cartridge loading. The battery has built-in short circuit protection. In the event of a short circuit, an internal polyfuse will trip. The fuse will reset itself within 5-10 seconds allowing the battery to resume normal operation. To charge the battery pack, do the following: Press the battery release on the pack to remove the battery from the back of the blower. (See Figure 1.) Battery release Figure 1 Figure 2 Place battery upside down into the charging port of the battery charger. (Figure 2.) Connect the battery charger to a 110-volt AC electrical outlet. Charge the battery pack for approximately four hours. While the battery is charging, the light on the charger will remain red. The charger light will illuminate green when charging is complete. Table-top gang chargers EVAGC with 6 ports are also available. Diagnostic functions are available for chargers (upon special order) including access to data such as number of cycles of operation, remaining charge capacity, etc. Details for these functions are available in the EVASMC2 charger user manual (upon special order).

3 EVA Series Powered Air-Purifying Respirator Blower Assembly User Manual Battery Storage Storage of Li Polymer batteries is relatively easy. Unlike Nickel batteries, they lose a very small amount of power (less than 0.5% per day) and therefore can be charged and stored ready for use. If long-term storage is required, it is best to store the battery in a cool place not below -5ºC with at least 40% charge still remaining. Discharging and re-charging the battery fully at least once every 3 months is suggested to ensure the longest possible life of the battery. Do not leave on the charger for more than 30 consecutive days. To maximize battery life, these guidelines should be followed: Remove the battery from the blower unit when not in use. Charge the battery before it is completely discharged. The low battery alarm indicates that the battery needs to be charged. The battery is designed with a circuit to protect the battery. It will not allow the battery to be discharged below a safe voltage for the cells, regardless of airflow, without the alarm sounding. When the battery reaches the voltage cutoff it will automatically cease operation. Always charge the batteries at room temperature or cooler. At higher temperatures, the battery pack may not accept a full charge. If the battery pack feels hot, let it cool for 30 minutes before charging. Do not charge battery packs in an enclosed cabinet without ventilation. Battery Fuel Gauge: WARNING DO NOT charge batteries in hazardous areas. EVA Battery Packs are equipped with an on-board fuel gauge to indicate the amount of remaining capacity left in the battery pack. To check the remaining capacity, simply depress the button labeled Push and LEDs will illuminate Figure 3 indicating the level of battery capacity remaining. When fully charged all four LEDs will illuminate green, and when 25% or less charge is available a single LED will illuminate red. Pre-Operational Inspection Prior to each work shift, perform the following Pre-Operational Inspection to ensure proper operation and to ensure that the unit is completely assembled. 1. Belt Mounted Blower Unit, Part No. EVA1 Check that the unit is clean and undamaged. Inspect for deterioration, physical damage and improper assembly. 2. Filter/Cartridges Inspect the filter/cartridge for any physical damage Check the label to ensure the filter/cartridge has not exceeded its use-by date. Inspect the gasket on the filter for any physical damage. Each filter comes with a permanent gasket. Ensure that the correct filter/cartridge is appropriate for the contaminant. Consult the NIOSH approval label and your own in-plant safety professional if you have any questions as to the suitability and efficiency of the Air-Purifying Element. Screw the cartridge into the port until hand-tight and the locking tab is secure. (Refer to Mounting and Replacing Filters on Blower Unit on page 5) 3. Battery Pack Check that the battery is not damaged. Check the Fuel Gauge to determine sufficient charge is available. Place the battery pack in the battery Figure 4 compartment on the blower. The battery tab should click when completely engaged. (See Figure 4) 4. Hood with Suspension or Hard Hat, or Loose Fitting Facepiece The hood is constructed of one of the following materials: Tychem QC, Tychem SL or Nomex (GRH). Depending on the model of the hood selected, it may be used with either a headband suspension or a hard hat (Note: RT Series hoods are NIOSH approved without a headband suspension or a hard hat). The loose fitting facepiece is constructed of Tychem QC and features an internal suspension. Inspect the hood or loose fitting facepiece for any physical damage. Mounting the Breathing Tube on the Blower Ensure that a rubber gasket is in place in the breathing tube coupler on the blower unit. Screw one end of the breathing tube into the blower unit. (Hand tight is sufficient.) (See Figure 5) Ensure that neither the breathing tube nor the filter is blocked. Ensure that the ON/OFF Switch is in the OFF position. Switch on the blower by pressing the on/ off button for 1-2 seconds confirmed by a short beep. If the Low Battery Alarm sounds at this time, the battery needs to be recharged. See instructions on page 2 regarding properly charging the battery. If the Low Flow Alarm sounds at this Figure 5 time, the hood, breathing tube and filter should be check for a blockage. Battery Pack / Pre-Operational Inspection 3

4 Checking Airflow / Air-Purifying Elements 4 Checking Airflow with the Airflow Indicator (PA1AFI - sold separately) With the blower switched ON and the filters/cartridges mounted, take the free end of the breathing tube in one hand, hold it upright and place the Airflow Indicator into the end of the tube. (See Figure 6). Apply a light downward pressure to the Airflow Indicator to get a reasonable seal at the breathing tube end. Ensure that the air outlet holes in the Airflow Indicator tube are not blocked. Two hands may be used if preferred, one to hold the breathing tube and one to hold the Airflow Figure 6 Indicator. The position of the ball in the Airflow Indicator should be observed. If any part of the ball is below the PASS LINE on the Airflow Indicator, check for: Blower malfunction. Clogged or damaged Air-Purifying filter elements on the HE filter. See Mounting and Replacing Cartridges on the Blower Unit on page 7. Low battery or battery malfunction. If the ball is completely above the PASS LINE on the Airflow Indicator, then the system is ready for use. If the blower malfunctions during use in a hazardous area: Remain calm and LEAVE the hazardous area immediately. DO NOT use a blower that fails the flow test (air flow indicator sold separately). Use ONLY Bullard filter/cartridges which comply with and have the NIOSH approval label and which are appropriate for the contaminant. Failure to observe these warnings could result in death or serious injury. EVA Series PAPR Air-Purifying Elements Principle of Operation The following filter/cartridge protection classification applies when used with any of the hoods or loose fitting facepieces. NIOSH Filter/Cartridges Protection Filter/Cartridge NIOSH / ANSI Color Code HE (particulate) PAPRFC3 Magenta OV/CL/HC/SD/CD/HF/HE PAPRFC4 Olive and Magenta AM/FM/MA/CL/HC/SD/CD/ HF/HE PAPRFC5 Olive and Magenta EN Filter/Cartridges* Protection Filter/Cartridge Color Code EN12941 P3 PAPRFC3 White A2P3 P3 R S L White, Brown, PAPRFC4 EN12941 Grey, Yellow * The user should not confuse the markings on a filter relating to other standard other than EN with the classification of this device when used with this filter. HE particulate filters are 99.97% effective against all particulate aerosols. Filters are supplied in quantities of three per box. The following abbreviations are approved by NIOSH to indicate the particulates, gases, or vapors which are removed by the gas/vapor cartridges: HE High Efficiency Particulate Air Filter for Powered Air-Purifying Respirators Use only the filter/cartridge(s) described in the above table. Do not change cartridges while in a hazardous atmosphere. Incorrect cartridge selection will invalidate all performance statements and approvals for this equipment. Follow established cartridge change schedules to ensure that cartridges are replaced before breakthrough occurs. Failure to follow these warnings could result in death or serious injury. *DO NOT fit filters directly to the hood. Mounting and Replacing Filters on the Blower Unit High efficiency particulate filters must be replaced when retained particles clog the filters and reduce air flow below acceptable levels, as indicated by testing with the Air Flow Indicator as described at left. Figure 7 To Replace Filters Remove the air-purifying element from its packaging, and inspect for damage. If in doubt do not use. Check that the air-purifying element has not exceeded its use-by date. Check that the filter connecting thread and gasket are in good condition. Check that the air-purifying element is appropriate to the hazard. If in doubt consult your respirator program administrator or supervisor. Check that the threads in the blower unit port are in good condition and clear of contaminant. Screw the air-purifying elements into the receptacles (see Figure 8) until the cartridge is hand tight. DO NOT OVERTIGHTEN. Check to see that the locking tab is secure. (see Figure 9) To Replace Combination Filter/Cartridge Follow the steps above, but beware that the filter locking tab is beneath the filter rim. (see Figure 10) Locking tab Locking tab Figure 8 Figure 9 Figure 10 Installing and Removing the Belt on the Blower Unit To install the belt With the blower filter side down, orient the lever locks as shown in Figure 11 Lay belt over blower as shown in Figure 12 Rotate level locks until they are oriented as shown in Figure 13 Figure 11 Figure 12 Figure 13 To Remove the Belt With the blower filter side down, orient the lever locks as shown in Figure 12 Remove belt from blower

5 EVA Series Powered Air-Purifying Respirator Blower Assembly User Manual Plastic insert may be removed for cleaning as shown in Figure See back page for more information on cleaning. Adjust Crown Straps for Vertical Fit To improve suspension comfort, adjust crown straps vertically by repositioning the crown strap posts in the crown straps. Vertical adjustment makes the headband ride higher or lower on the wearer s head. To adjust, push crown strap post from slot, move to new slot and snap in to secure. Repeat for other crown strap post (Figure 18). Crown strap Crown strap post Figure 14 Figure 15 Donning the Blower and Respirator Initial Donning Prepare to don the blower, battery and hood in a safe, hazard-free area and do the following: Ensure that the filter/cartridges used are suitable for the contaminant in question and are compatible with the EVA1 Blower Unit. Check that the filter/cartridge is properly mounted on the blower unit. Place the battery in the battery compartment on the back of the blower. Fit the blower and belt around the user s waist and adjust the belt for a comfortable fit (suspenders are also available). Remove the belt and blower to install the hood or loose fitting facepiece and corresponding breathing tube. WARNING The use of any filter/cartridge not approved with the EVA1 blower unit may put the user at risk and could result in death or serious injury. Donning the EVA with the CC20 Series or GR50 Series Hood Adjusting and Installing Headband Suspension in Hood 20LF and 20LF2 series loose-fitting facepiece hoods have a sewn-in headband. The 20SICH, 20TICH and GRH Hoods may use a hard hat or suspension. RT Series hoods do not use a suspension. 1. Adjust headband before installing into hood. 2. Turn ratchet until it is at its largest size. Ratchet Knob 3. Place suspension on head. 4. Adjust ratchet knob until snug and comfortable fit achieved. (Figure 16) 5. Remove from head. 6. Place suspension into hood. 7. Snap 4 white buttons of suspension into 4 white buttons on hood. (Figure 17) Figure 17 Figure 16 Brow pad Figure 18 If the hood rises off your head during use, first verify proper air pressure, then select a different hood for your application, or use the optional chin strap. Adjusting and Installing Hard Hat in Respirator Hood (20SICH & 20TICH or GRH) 1. Assemble and adjust the standard Bullard hard hat suspensions RS4PC or RS6PC or the optional ratchet suspensions RS4RC or RS6RC by following the directions on instruction sheet attached to headband on hard hat. Read all hard hat warning labels and instructions. The following Bullard hard hat models are NIOSH approved for use with CC20 Series and GR50 Series respirator hoods: C30, C30R, S51 and S51R. 2. If desired, install and adjust optional ES42 hard hat chinstrap. 3. Before inserting hard hat into hood, remove the two adhesive-backed Velcro strips attached to the Velcro piece that is sewn into the hood (see Figures 19 & 20). 4. Peel the backing off the longer Velcro tab and apply it Figure 19 to the inside center rear of the hard hat, about 1/4 up from the edge. Apply shorter Velcro tab to the underside of the brim of the hard hat (see Figure 19). 5. Insert hard hat into respirator hood with cap visor facing front of hood (see Figure 19). 6. Tuck cap brim on top of front elastic Velcro band sewn into hood (see Figure 20). 7. Loop the Velcro strip sewn inside the hood around the back of the cap and affix it to the corresponding Velcro tab previously installed inside the hard hat in step 4 (see Figure 21). 8. Remove protective plastic from plastic lens of respirator hood. If desired, apply optional 20LC or 20LCL adhesive-backed lens covers designed to protect the respirator s plastic lens. Apply 2-3 lenses at a time. When lens becomes soiled, remove by pulling tab at edge of lens cover to clear your vision. Velcro strip Velcro tabs Window Front elastic band Figure 20 Figure 21 Velcro Strip Donning the Blower / CC20 Series Hood Use 5

6 RT Series Hood Use 6 Installing Breathing Tube Assembly in CC20 or GRH Hoods For hoods without a threaded To remove port at the rear, Breathing Tubes PA1BT, PA1BTXS and PA1BTXL will To tighten attach to the hood with a clamp as follows: To tighten 1. Remove nylon clamp from plastic anchor plate on hood (see Figure 22). 2. Insert the open end of the Figure 22 breathing tube approximately five inches into hood s air entry sleeve (see Figure 23). Do not insert breathing tube into hood air entry sleeve more than 6 inches as it may cause a flow restriction. 3. Install nylon clamp over air entry sleeve and breathing tube, inserting clamp locks through two holes in plastic anchor plate that is sewn into hood. Locks should face away from user s Figure 23 neck (see Figure 24). The air entry sleeve seams should be on the top and bottom of the breathing tube when properly installed and worn. 4. Engage clamp locks and squeeze together until tight. Air entry sleeve should not be twisted or restricted (see Figure 25). If so, then remove the clamp and repeat steps 2-4. For hoods with a threaded port at the rear (designated with a T suffix), Breathing Figure 23A Tubes PAHBT, PAHBTXS, PAHBTXL will attach to the hood by the threading into the port at the rear (See Figure 23A). Figure 24 Correct Figure 25 Twisted incorrect warning Do not put on or remove these respirators in a hazardous atmosphere except for emergency escape purposes. Failure to heed these warnings could result in death or serious injury. Donning the CC20 or GRH and EVA 1. With PAPR Blower Unit Running, put on CC20 or GRH Series respirator hood. 2. Position headband suspension or hard hat for a comfortable fit. 3. If using an optional chin strap, pull elastic strap under your chin. Adjust for a secure and comfortable fit. 4. Tuck inner bib of hood into shirt or protective clothing if using hood with inner bib (see Figure 26). 5. Pull respirator outer bib over collar of shirt or protective clothing. 6. Ensure that the neck cuff is down below the chin and that the air outlets of the cuff (see Figure 27) are not restricted. If the neck cuff is not below the chin, then pull down before continuing Figure 27 (See Figure 28). Figure 26 RT Series Hood Use Installing Breathing Tube Assembly in RT Series Respirator Hoods For hoods without a threaded port at the rear, Breathing Tubes PA1BT, PA1BTXS and PA1BTXL will attach to the hood with a clamp as follows: 1. Remove nylon clamp from the breathing tube (see Figure 23). 2. Insert the open end of the breathing tube approximately five inches into hood s air entry sleeve (see Figure 29). Do not insert breathing tube into hood air entry sleeve more than 6 inches as it may cause a flow restriction. 3. Install nylon clamp over air entry sleeve and breathing tube. If desired, 2 or more clamps may be used(see Figure 30). The air entry sleeve seams should be on the sides of the breathing tube when properly installed and worn. 4. Engage clamp locks and squeeze together until tight. Air entry sleeve should not be twisted or restricted (see Figure 31). If so, then remove the clamp and repeat steps With PAPR blower unit running, put on RT Series respirator hood. Pull the hood over your head until the neck cuff is securely around your neck. Correct 6. Ensure that the neck cuff is down below the chin and that the air outlets of the cuff are not restricted. If Figure 31 the neck cuff (see Figure 27) is not below the chin, then pull down before continuing (See Figure 28). Figure 29 Figure 30 Incorrect Correct Figure 28 Twisted incorrect

7 EVA Series Powered Air-Purifying Respirator Blower Assembly User Manual WARNING The user should ensure that the neck cuff is unrestricted all around the neck to allow proper inflation and reduce restrictions. Battery run time will be reduced by a restricted or improperly donned hood. For hoods with a threaded port at the rear (designated with a T suffix), Breathing Tubes PAHBT, PAHBTXS, PAHBTXL will attach to the hood by the threading into the port at the rear (See Figure 23A). The RT3 and RT4 hoods have an adjustable velcro strap near the top of the lens that allows the user to customize the curvature of the lens to his/her personal preference. This strap may be removed if desired. 7. Make sure that the breathing tube is not twisted after donning. 8. T uck inner bib of hood into shirt or protective clothing (see Figure 26). 9. Pull respirator outer bib over collar of shirt or protective clothing. Pull the long outer bib down on the outside of clothing and secure with tie down straps or tape (if employer operating procedures will allow.) Loose-Fitting Facepiece Use Installing Breathing Tube Assembly in Loose- Fitting Facepieces Figure The 20LFM, 20LFL, 20LF2S, 20LF2M and 20LF2L loose-fitting facepieces have a sewn-in breathing tube connector on the back. The PA20LFBT breathing tube has a special connector on the hood end with bayonet type pins. 2. Insert the bayonet connector of the PA20LFBT breathing tube in the hood connector and turn clockwise until it locks in place (see Figure 32). Available in large 20LF2L or 20LFL, medium 20LF2M or 20LFM, and small 20LF2S. Select the size that fits most comfortably and matches your head size. Remove the protective cover from the visor. Pull the hood over your head and adjust the headband around your head and the elasticized edge of the faceseal under your chin. Make sure that the breathing tube is not twisted after donning. Final Donning: Attach the other end of breathing tube to blower unit (if not already attached) by screwing adapters together. Remove any protective film covering the lens of the headpiece. Put on the belt and blower assembly and make any final adjustments to the belt as necessary, keeping the breathing tube and hood behind the head. Turn the blower on by depressing and holding the on/off switch (Figure 33) for approximately 1 second indicated by a short beep. Buckle the belt onto the waist (blower unit should be in the lower back of the wearer). Don the headpiece. on/off switch Choose speed setting (see below). Place the hood on the head making any final adjustments to the fit as required at this time to ensure a comfortable and stable fit. Tuck inner bib into coveralls or shirt if using a hood with inner bib. Figure 33 WARNING Do not enter a hazardous area until you are sure that the blower and hood are fully operational and the blower is running. The user should periodically leave the hazardous area to check the airflow through the system. If the low battery or low flow alarm should sound, or if the user experiences any difficulty in breathing, or senses any taste or any odors from the hazard, the user should leave the hazardous area immediately. Failure to observe these warnings could result in death or serious injury. CC20 Single Bib CC20 Double Bib RT Series 20LFL 20LF2L GRH Speed Selection Final Donning Front Back The EVA1 Blower is equipped with the ability for the user to select one of two speeds for operation. When the unit is initially turned on, the blower will operate at approximately 8.5 cfm = 240 lpm (high speed). Note: The battery life is reduced at the higher speed. Pressing the on/off switch will change the speed to approximately 7 cfm = 198 lpm (low speed). Pressing the on/off switch additional times will toggle the unit between the two speeds. Speed change is confirmed by a short beep. Loose-Fitting Facepiece Use/Final Donning/Speed Selection 7

8 Low Battery Alarm and Low Flow Alarm The EVA1 Blower unit is equipped with a Low Battery Alarm and a Low Flow Alarm. The Low Battery Alarm will sound an intermittent 77 dba electronic beep indicating that there are approximately 15 minutes of remaining battery capacity. The delays between beeps will get shorter and shorter as time runs out. The Low Flow Alarm will sound a continuous 77 dba electronic beep indicating that the flow to the hood has dropped below the design specification of 185 lpm = 6.5 CFM (Note: The NIOSH minimum required flow is 170 lpm = 6 CFM). When either of these alarms sounds, the user should immediately do the following: Leave the hazard area Remove the headpiece Disconnect the breathing tube from the hood Check the airflow with the airflow indicator (see page 4). Check the operation of the low-flow alarm by blocking the end of the breathing tube. The device will first ramp up to compensate and if correct flow cannot be achieved, the alarm will sound within 5 seconds. If the airflow indicator indicates insufficient airflow, the battery should be fully charged (see Battery Pack on page 2), and/or the filter/cartridge should be replaced. The EVA1 blower is provided with a circuit to protect the battery. It will not allow the battery to be discharged below a safe voltage for the cells, regardless of airflow, without the Alarm sounding. When the battery reaches the voltage cutoff it will automatically cease operation. When the Low Battery Alarm sounds and the filter cartridges are not clogged, the battery should be recharged to protect the battery and thereby prolong the working life of the unit. If the ball in the Airflow Indicator is BELOW or PARTLY BELOW the PASS LINE with a fully charged battery, the filter cartridges may need to be changed. Doffing the Respirator Prepare to doff the blower, battery and hood in a safe, hazard-free area and do the following (in conjunction with your employer s standard operating procedures): Remove the hood. Turn the blower off by holding down the on/off switch for 5 seconds. This is confirmed by a long beep and a shut down of the motor. Remove the waist belt. Disconnect the hood from the breathing tube. Disconnect the breathing tube from the blower. Clean and inspect components as necessary. Place battery on charger (as desired). Place components in storage. WARNING /Low Battery Alarm/Doffing the Blower / Troubleshooting Troubleshooting The following guide will assist you in troubleshooting to locate possible issues with your respirator: The use of any filter/cartridge not approved with the EVA1 blower unit may put the user at risk and could result in death or serious injury. Circumstance Possible Cause(s) Solution Low Battery Alarm is sounding Low Voltage Charge the battery Blower malfunction Return blower for anyalysis Low Flow Alarm is sounding Clogged/damaged air-purifying filter element Replace the filter/cartridge Battery Low Re-charge the battery Blower malfunction Leave hazardous area immediately and check equipment. If the problem persists and no damage is found, return equipment for repair. Replace breathing tube and/or hood. Hood neck cuff is restricting flow Adjust neck cuff position Smell or taste contaminant Equipment damaged Leave hazardous area immediately and check equipment Filter needs to be replaced Replace filter Low airflow Leave hazardous area immediately and check equipment If the problem persists and no damage is found, return equipment for repair Blower unit does not run full service life Damaged Battery Return battery for analysis Malfunctioning Battery Charger Return charger for analysi Hood neck cuff is restricting flow Adjust neck cuff position 8

9 EVA Series Approval Label EVA Series Powered Air-Purifying Respirator This respirator is approved only in the following configurations: RESPIRATOR COMPONENTS CAUTIONS AND LIMITATIONS 2 ACCESSORIES BATTERY BELT ASSEMBLY CARTRIDGE ASSEMBLY BLOWER UNIT ASSEMBLY FILTER ASSEMBLY ALTERNATE BREATHING TUBES ALTERNATE SUSPENSION / HARD HAT ASSEMBLIES TC- PROTECTION 1 ALTERNATE HOOD ASSEMBLIES 20LFL 20LFM 20LF2L 20LF2M 20LF2S 20TJN 20TJNT 20TPN 20TPNT 20TICN 20TICNT 20SICVN 20SICVNT 20TPCN 20TPCNT 20SICN 20SICNT 20TICSN 20TICSNT GRH GRHT 20TICH 20TICHT 20SICH 20SICHT 20SICVH 20SICVHT RT1 RT1T RT2 RT2T RT3 RT3T RT4 RT4T 20TG 20RT 30XXR 30XXP 51XXR 51XXP PA1BT PA1BTXS PA1BTXL PAHBT PAHBTXS PAHBTXL PA20LFBT PA20LFBTXS PA20LFBTXL EVA1 PAPRFC3 PAPRFC4 PAPRFC5 EVABAT1 EVABELT1 EVASMC EVAEXT1 PA1AFI 20NC ES42 20LCL GRHOL1 RTLC 20SLBTC PAPRSC2 20QCBTC MB1 POLYBTC EVAGC PAPRSUSP1 PAPRPFCOVER2 PAPRSC3 PAPRPF2 20LFLEF 20LF2LEF 20LF2MEF 20LF2SEF EVABELT2 21C-0836 HE X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X ABCFHIJLMNOP 23C-2510 OV/CD/CL/HC/HF/SD/HE X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X ABCFHIJLMNOP 23C-2886 AM/FM/MA/CL/HC/SD/ X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X ABCFHIJLMNOP CD/HF/HE 1 Protection HE - High Efficiency Particulate Air Filter for Powered Air Purifying Respirators CD - Chlorine dioxide CL - Chlorine HC - Hydrogen chloride HF - Hydrogen fluoride SD - Sulfur Dioxide AM - Ammonia FM - Formaldehyde MA - Methylamine J. Failure to properly use and maintain this product could result in injury or death. L. Follow the manufacturer s instructions for changing cartridges and / or filters. M. All approved respirators shall be selected, fitted, used and maintained in accordance with MSHA, OSHA and other applicable regulations. N. Never substitute, modify, add or omit parts. Use only exact replacement parts in the configuration specified by the manufacturer. O. Refer to User s Instructions, and/or maintenance manuals for information on use and maintenance of these respirators. P. NIOSH does not evaluate respirators for use as surgical masks. 2 Cautions and Limitations A. Not for use in atmospheres containing less than 19.5% oxygen. B. Not for use in atmospheres immediately dangerous to life or health. C. Do not exceed maximum use concentrations established by regulatory standards. F. Do not use this respirator if airflow is less than four cfm (115 lpm) for tight-fitting facepieces or six cfm (170 lpm) for hoods and / or helmets. H. Follow established cartridge and canister change schedules or observe ESLI to ensure that cartridges and canisters are replaced before breakthrough occurs. I. Contains electrical parts which have not been evaluated as an ignition source in flammable or explosive atmospheres by MSHA / NIOSH. NIOSH Approval Label 9

10 Cleaning Avoid contaminant entry into the breathing tube, as this will compromise respiratory protection and could result in death or serious injury. Consult your local safety professional if you suspect that contaminant has entered the breathing tube. When cleaning the equipment, do the following: Ensure water does not enter filter/cartridges. Replace wet filter/cartridges. DO NOT use gasoline, organic-based solvents, or chlorinated degreasing fluids (such as trichloroethylene), as they will cause damage. DO NOT immerse the equipment in water or other cleaning fluid, as this may cause contamination in the breathing tube and blower interior that will be difficult to remove. Use a lint-free cloth moistened in a mild solution of soap and warm water to clean the outer surface of the equipment. Failure to observe the instructions and warnings in this manual invalidates all performance statements and approvals for this equipment and could result in death or serious injury. The following chemicals have been tested and approved as cleaning agents for the blower housing, belt and battery: A. Process NPD (1.256) from Steris B. Spor Klenz (undiluted) from Steris C. Clorox liquid bleach at 10% concentration D. Sani-Cloth HB wipes E. 100% Methanol F. 70% IPA Once filter/cartridges have reached the end of their useful life, discard in accordance with federal, state, and local guidelines, and in conformance with plant safety regulations. Consult the appropriate CC20, RT or GR50 Series Hood User Manual for cleaning instructions for the hood components. Storage When the blower is completely dry, store in a clean, dry area, away from direct sunlight and sources of direct heat. The storage temperature should be between 23º F to 129º F (-5º C to 54º C) with humidity less than 90% RH. Consult the appropriate CC20, RT or GR50 Series Hood User Manual for storage instructions on hood components One Year Limited Warranty Bullard warrants to the original purchaser that the EVA Powered Air-Purifying Respirator and Loose-Fitting Facepiece or Hood will be free of defects in material and workmanship under normal use and service for a period of one (1) year from the date of purchase. Bullard s obligation under this warranty is limited to repairing or replacing, at its option, articles that are returned within the warranty period and that are, after examination, shown to Bullard s satisfaction to be defective, subject to the following limitations; a) EVA Powered Air-Purifying Respirator and Loose-Fitting Facepiece or Hood must be returned to the Bullard factory with shipping charges prepaid. b) EVA Powered Air-Purifying Respirator and Loose-Fitting Facepiece or Hood must not be altered from its original factory configuration. c) EVA Powered Air-Purifying Respirator and Loose-Fitting Facepiece or Hood must not have been misused, subjected to negligent use, or damaged in transport. d) The date of purchase is within the one year warranty period. (A copy of the purchaser s original invoice showing the date of purchase is required to validate warranty coverage.) In no event shall Bullard be responsible for damages for loss of use or other indirect, incidental, consequential or special costs, expenses or damages incurred by the purchaser, notwithstanding that Bullard has been advised of the possibility of such damages. ANY IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO ONE (1) YEAR FROM THE DATE OF PURCHASE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, or allow limitations on how long an implied warranty lasts, so the above limitations or exclusion may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Warranty/Return Authorization 10

11 EVA Series Powered Air-Purifying Respirator Blower Assembly User Manual Ordering Information Respirator Assemblies (includes blower, battery, charger, breathing tube and hood) *Add DB suffix for vinyl belt Loose Fitting Facepiece Systems: EVA20LF2L Tychem QC loose-fitting facepiece system - large EVA20LF2M Tychem QC loose-fitting facepiece system - medium EVA20LF2S Tychem QC loose-fitting facepiece system - small Single Bib Hood Systems: EVA20TJ Tychem QC single bib hood system EVA20TP Tychem QC single bib hood system with solvent resistant lens Double Bib Hood Systems: EVA20TIC Tychem QC double bib hood system EVA20SIC Tychem SL double bib hood system EVA20TPC Tychem QC double bib hood system with solvent resistant lens EVA20TICS Tychem QC extra long double bib hood system with taped seams EVA20TICH Tychem QC double bib hood for hard hat system (hard hat included) EVA20SICH Tychem SL double bib hood for hard hat system (hard hat included) EVART3 Tychem QC headband-free extra large lens double bib hood system EVART4 Tychem SL headband-free extra large lens double bib hood system EVAGRH Nomex double bib hood for grinding system Blower Assemblies EVA1 Blower unit only EVA2 Blower unit, battery and charger EVA3 Blower unit, battery, charger and HEPA filter Replacement Batteries and Chargers EVASMC Quick charger (1 port) EVASMC2 Analyzing Charger EVAGC Table top gang charger for EVABAT1 (6 ports) EVABAT1 Lithium Polymer Battery Pack (black) Replacement Cartridges PAPRFC3 HE (6 per box) PAPRFC4 OV/AG/HE (6 per box) PAPRFC5 AM/FM/MA/AG/HE (6 per box) Respirator Hoods Single bib hood, for use with headband suspension 20TJ/20TJT Tychem QC 20RT headband suspension 20TJN/20TJNT Tychem QC No headband suspension 20TP/20TPT Tychem QC 20RT headband suspension, solvent-resistant polyester lens 20TPN/20TPNT Tychem QC No headband suspension, solvent-resistant polyester lens Double bib hood for use with headband suspension 20TIC/20TICT Tychem QC 20RT headband suspension 20TICN/20TICNT Tychem QC No headband suspension 20TPC/20TPCT Tychem QC 20RT headband suspension, solvent-resistant polyester lens 20TPCN/20TPCNT Tychem QC No headband suspension, solvent-resistant polyester lens 20TICS/20TICST Tychem QC 20RT headband suspension, taped and sealed seams 20TICSN/20TICSNT Tychem QC No headband suspension, taped and sealed seams 20SIC/20SICT Tychem SL 20RT headband suspension, taped and sealed seams 20SICN/20SICNT Tychem SL No headband suspension, taped and sealed seams 20SICV/20SICVT Tychem SL 20RT headband suspension, taped and sealed seams, PVC lens 20SICVN/20SICVNT Tychem SL No headband suspension, taped and sealed seams, PVC lens Double bib hood for use with Bullard hard hat 20TICH/20TICHT Tychem QC Hard hat not included 20SICH/20SICHT Tychem SL Hard hat not included, taped and sealed seams 20SICVH/20SICVHT Tychem SL Hard hat not included, taped and sealed seams, PVC lens Double bib grinding hood for use with Bullard hard hat or suspension GRH/GRHT Nomex, Hard hat not included Loose fitting facepieces with sewn-in suspension 20LFL Tychem QC, Large 20LFM Tychem QC, Medium 20LF2S Tychem QC, Small, narrow profile 20LF2M Tychem QC, Medium, narrow profile 20LF2S Tychem QC, Large, narrow profile Double bib hood for use without a headband suspension RT1/RT1T Tychem QC RT2/RT2T Tychem SL RT3/RT3T Tychem QC RT4/RT4T Tychem SL Accessory Items for Hoods 20LCL Mylar lens covers, CC20 Series (25/pkg) RTLC Mylar lens covers, RT Series (25/pkg) MB1 Outer lens, GRH Series (10/pkg) 20LC Mylar lens covers, GRH Series (25/pkg) Headband Suspensions and Hard Hats 20TG Standard headband suspension 20RT Sure-Lock ratchet headband suspension 3000 Hard hat with standard suspension, white 3000R Hard hat with ratchet suspension, white 51WHP Hard hat with standard suspension, white 51WHR Hard hat with ratchet suspension, white Accessories for Headbands Suspension and Hard Hats RS6PC Standard replacement suspension for 30WHP hard hat RS6RC Replacement ratchet suspension for 30WHR hard hat RS4PC Standard replacement suspension for 51WHP hard hat RS4RC Replacement ratchet suspension for 51WHR hard hat 20NC Chinstrap for 20TG and 20RT headband suspension ES42 Chinstrap for 3000 and 5100 hard hats Replacement Parts and Accessories EVABELT1 Replacement belt EVABELT2 Vinyl replacement belt EVAEXT1 Extension belt kit PAPRSUSP1 PAPR suspenders (1 pair) PA1AFI Air flow indicator PAHBT Powered air hood breathing tube assembly; standard length PAHBTXS Powered air hood breathing tube assembly; short length PAHBTXL Powered air hood breathing tube assembly; long length PA1BT Hood breathing tube assembly; includes tube and clamp; standard length PA1BTXS Hood breathing tube assembly; includes tube and clamp; short length PA1BTXL Hood breathing tube assembly; includes tube and clamp; long length PA20LFBT Loose fitting facepiece breathing tube assembly; standard length PA20LFBTXS Loose fitting facepiece breathing tube assembly; short length PA20LFBTXL Loose fitting facepiece breathing tube assembly; long length PA1BTS Breathing tube/cartridge seal EVABAT1 Battery pack S18051 Breathing tube clamp (10/pack) Ordering Information 11

12 EVA1 - Powered Air-Purifying Respirator EVA Series Powered Air-Purifying Respirator Blower Assembly User Manual (for use with SparxLift Welding Helmets) US-NIOSH Powered Air-Purifying Respirator with High Efficiency (HE) Filters - Approval No. TC-21C-0940 (PAPRFC3) Approval No. TC-21C-0941 (PAPRFC3) Cautions and Limitations A. Not for use in atmospheres containing less than 19.5% oxygen. B. Not for use in atmospheres immediately dangerous to life or health. C. Do not exceed maximum use concentrations established by regulatory standards. F. Do not use respirator if airflow is less than four cfm (115 lpm) for tight fitting face pieces or six cfm (170 lpm) for hoods and/or helmets. H. Follow established cartridge and canister change schedules or observe ESLI to ensure that cartridges and canisters are replaced before breakthrough. I. Contains electrical parts that may cause an ignition in flammable or explosive atmospheres. J. Failure to properly use and maintain this product could result in injury or death. L. Follow the manufacturer s user instructions for changing cartridges and/ or filters. M. All approved respirators shall be selected, fitted, used and maintained in accordance with MSHA, OSHA and other applicable regulations. N. Never substitute, modify, add or omit parts. Use only exact Bullard replacement parts in the configuration as specified by the manufacturer. O. Refer to User s Instructions and/or maintenance manuals for information on use and maintenance of these respirators. P. NIOSH does not evaluate respirators for use as surgical masks. * At very high work rates, the pressure in the device may become negative at peak inhalation flow. Always use genuine SparxLift front and inside cover plates. Failure to do so may result in injury and will void the warranty. The SparxLift is not designed for overhead welding without the use of additional protection. Check your helmet for physical damage and test it regularly. If your helmet is damaged or is not working normally have it tested and repaired before use. Always select the appropriate shade before use according to the type of welding and current/amperes used. When in doubt refer to your authorized safety representative. EN175 EN379 ANSI Z87S Use strictly in accordance with instructions, labels and limitations pertaining to the EVA Series respirator. 1. The EVA Series respirator does not supply oxygen. Use only in adequately ventilated areas containing at least 19.5% oxygen. 2. Do not use when concentrations of contaminants are immediately dangerous to life or health (IDLH). This term is defined in 29CFR (b). 3. Do not use these respirators for respiratory protection during abrasive blasting or clean up. 4. Do not use in circumstances where the airborne concentration level of contaminant exceeds maximum use concentration for this type of respirator as established by regulatory standards. 5. Leave area immediately if: Breathing becomes difficult Dizziness or other distress occurs You taste or smell the contaminant Unit becomes damaged Battery alarm activates Low Flow alarm activates 6. This apparatus must not be worn with the blower unit switched off. If the blower is switched off, a rapid build-up of carbon dioxide and depletion of oxygen may occur, which could result in death or serious injury. 7. Never alter or modify this respirator. Use only Bullard NIOSHapproved EVA Series components and replacement parts for this respirator. 8. This device is not immune to highly powered RFI/EMI emissions. Failure to follow these warnings could result in death or serious injury.

13 Component Diagram Welding Helmet with Shroud Breathing Tube with Nomex Cover Blower Unit with Battery and Belt HE Filter with Spark Arrest Cover Helmet with Shroud PAHBTBK Breathing TubeS PA1BT - STANDARD LENGTH PA1BTXS - XS LENGTH PA1BTXL - XL LENGTH Breathing Tube Cover NMXBTC Blower and Battery EVA Cover with Spark Arrest Filter Belts EVABELT1 EVABELT2 EVADCFR1

14 EVA Series Powered Air-Purifying Respirator Blower Assembly User Manual (for use with SparxLift Welding Helmets) EVA Series - Principle of Operation The EVA Series Powered Air-Purifying Respirator (PAPR) System is configured in six parts: 1. The blower and belt assembly: EVA1 Blower Unit EVABELT1 Comfort/Decon Belt PA1AFI Air Flow Indicator 2. The battery pack (Part No. EVABAT1). One fully charged pack will power the blower for approximately four to ten hours depending upon factors such as speed, cartridge selected and cartridge loading. 3. The breathing tube, which is available in 4 options: PAHBT Powered Air Hood Breathing Tube Assembly (standard length) PAHBTXS Powered Air Hood Breathing Tube Assembly (short length) PAHBTXL Powered Air Hood Breathing Tube Assembly (long length) PAHBTBK Powered Air Hood Breathing Tube Assembly for Back Pack 4. The High Efficiency Particulate Absolute (HEPA) filter. 5. SparxLift welding helmet with Shroud. 6. The Battery Charger: EVASMC Quick charger (single port) EVASMC2 Analyzing charger EVAGC Gang charger (six port) The blower unit draws in ambient air through the filter. The purified air is blown into the wearer s hood through the breathing tube. A flow indicator is provided to check that there is an adequate volume of air available to the wearer prior to use. The system is designed to operate at a minimum air flow of approximately seven cubic feet of air per minute (210 liters per minute) in the hood under normal use on the standard speed setting, and eight and one-half cubic feet of air per minute (241 liters per minute) in the hood under normal use on the high speed setting. A feedback loop from the Mass Flow Sensor to the impellor continually monitors and adjusts the air flow to keep it constant at the design set point. The units are designed for use at temperatures from 23ºF to 122ºF (-5ºC to 50ºC). A high temperature alarm will sound at 50ºC (122ºF). The battery pack mounts in a compartment on the back of the blower. A fully charged battery pack will power the blower for approximately four to ten hours depending upon factors such as speed selected, cartridge selected, and filter/cartridge loading. The EVA Series Blower is equipped with two alarms: A 77db continuous alarm will sound when the air flow falls below approximately 185 lpm and a 77db intermittent chirp alarm will activate to indicate that the battery has approximately 15 minutes of remaining capacity. Battery Pack One fully charged battery pack will power the blower for approximately four to eight hours depending upon factors such as speed selected, cartridge selected and filer/cartridge loading. The battery has built-in short circuit protection. In the event of a short circuit, an internal polyfuse will trip. The fuse will reset itself within 5-10 seconds allowing the battery to resume normal operation. To charge the battery pack, do the following: Press the battery release on the pack to remove the battery from the back of the blower (see Figure 1). Battery release Figure 1 Figure 2 Place battery upside down into the charging port of the battery charger (Figure 2). Connect the battery charger to a 110-volt AC electrical outlet. Charge the battery pack for approximately four hours. While the battery is charging, the light on the charger will remain red. The charger light will illuminate green when charging is complete. Table-top gang chargers EVAGC with 6 ports are also available. Diagnostic functions are available for chargers (upon special order) including access to data such as number of cycles of operation, remaining charge capacity, etc. Details for these functions are available in the EVASMC2 charger user manual (upon special order). DO NOT charge batteries in hazardous areas. Battery Storage Storage of Li Polymer batteries is relatively easy. Unlike Nickel batteries, they lose a very small amount of power (less than 0.5% per day) and therefore can be charged and stored ready for use. If long-term storage is required, it is best to store the battery in a cool place with at least 40% charge still remaining. Discharging and re-charging the battery fully at least once every 3 months is suggested to ensure the longest possible life of the battery. Do not leave on the charger for more than 30 consecutive days. To maximize battery life, these guidelines should be followed: Remove the battery from the blower unit when not in use. Charge the battery before it is completely discharged. The low battery alarm indicates that the battery needs to be charged. The battery is designed with a circuit to protect the battery. It will not allow the battery to be discharged below a safe voltage for the cells, regardless of airflow, without the alarm sounding. When the battery reaches the voltage cutoff it will automatically cease operation. Always charge the batteries at room temperature or cooler. At higher temperatures, the battery pack may not accept a full charge. If the battery

15 pack feels hot, let it cool for 30 minutes before charging. Do not charge battery packs in an enclosed cabinet without ventilation. Figure 3 Battery Fuel Gauge: EVA Battery Packs are equipped with an on-board fuel gauge (Figure 3) to indicate the amount of remaining capacity left in the battery pack. To check the remaining capacity, simply depress the button labeled Push and LEDs will illuminate indicating the level of battery capacity remaining. When fully charged all four LEDs will illuminate green, and when 25% or less charge is available a single LED will illuminate red. Pre-Operational Inspection Prior to each work shift, perform the following Pre-Operational Inspection to ensure proper operation and to ensure that the unit is completely assembled. 1. Belt Mounted Blower Unit, Part No. EVA1 Check that the unit is clean and undamaged. Inspect for deterioration, physical damage and improper assembly. 2. Filter/Cartridges Inspect the filter/cartridge for any physical damage Check the label to ensure the filter/cartridge has not exceeded its use-by date. Inspect the gasket on the filter for any physical damage. Each filter comes with a permanent gasket. Ensure that the correct filter/cartridge is appropriate for the contaminant. Consult the NIOSH approval label and your own in-plant safety professional if you have any questions as to the suitability and efficiency of the Air-Purifying Element. Screw the cartridge into the port until hand-tight and the locking tab is secure (Refer to Mounting and Replacing Filters on Blower Unit on page 5). 3. Battery Pack Check that the battery is not damaged. Check the Fuel Gauge to determine sufficient charge is available. Place the battery pack in the battery compartment on the blower. The battery tab should click when completely engaged (Figure 4). Figure 4 4. Helmet with Shroud (SLS1 or SLS2) Inspect both the helmet and the shroud for any physical damage Inspect shroud to helmet velcro attachment and ensure proper installation. To provide a general check of system status you may wish to set the shade control to 11 and hold the helmet towards a bright incandescent light source. Under normal circumstances the filter will change from light to dark state and back to light state again as you move the helmet away. Mounting the Breathing Tube on the Blower Ensure that a rubber gasket is in place in the breathing tube coupler on the blower unit. Screw one end of the breathing tube into the blower unit - hand tight is sufficient (Figure 5). Ensure that neither the breathing tube nor the filter is blocked. Ensure that the ON/OFF Switch is in Figure 5 the OFF position. Switch on the blower by pressing the on/off button for 1-2 seconds confirmed by a short beep. If the Low Battery Alarm sounds at this time, the battery needs to be recharged. See instructions on page 2 regarding properly charging the battery. If the Low Flow Alarm sounds at this time, the hood, breathing tube and filter should be check for a blockage. Checking Airflow with the Airflow Indicator (PA1AFI) With the blower switched ON and the filters/cartridges mounted, take the free end of the breathing tube in one hand, hold it upright and place the Airflow Indicator into the end of the tube (Figure 6). Figure 6 Apply a light downward pressure to the Airflow Indicator to get a reasonable seal at the breathing tube end. Ensure that the air outlet holes in the Airflow Indicator tube are not blocked. Two hands may be used if preferred, one to hold the breathing tube and one to hold the Airflow Indicator. The position of the ball in the Airflow Indicator should be observed. If any part of the ball is below the PASS LINE on the Airflow Indicator, check for: Blower malfunction. Clogged or damaged Air-Purifying filter elements on the HE filter. See Mounting and Replacing Cartridges on the Blower Unit on page 7. Low battery or battery malfunction. If the ball is completely above the PASS LINE on the Airflow Indicator, then the system is ready for use. If the blower malfunctions during use in a hazardous area: Remain calm and LEAVE the hazardous area immediately. DO NOT use a blower that fails the flow test (air flow indicator sold separately). Use ONLY Bullard filter/cartridges which comply with and have the NIOSH approval label and which are appropriate for the contaminant. Failure to observe these warnings could result in death or serious injury.

16 EVA Series Powered Air-Purifying Respirator Blower Assembly User Manual (for use with SparxLift Welding Helmets) EVA Series PAPR Air-Purifying Elements Principle of Operation The following filter/cartridge protection classification applies when used with any of the hoods or loose fitting facepieces. NIOSH Filter/Cartridges Protection Filter/Cartridge NIOSH / ANSI Color Code High Efficiency (particulate) PAPRFC3 Magenta EN Filter/Cartidges Protection Filter/Cartridge Color Code EN12941 P3 PAPRFC3 White HE particulate filters are 99.97% effective against all particulate aerosols. Filters are supplied in quantities of six per box. Use only the filter/cartridge(s) described in the above table. Do not change filter/cartridges while in a hazardous atmosphere. Incorrect filter/cartridge selection will invalidate all performance statements and approvals for this equipment. Failure to follow these warnings could result in death or serious injury. *DO NOT fit filters directly to the hood. Mounting and Replacing Filters on the Blower Unit High efficiency particulate filters must be replaced when retained particles clog the filters and reduce air flow below acceptable levels, as indicated by testing with the Air Flow Indicator as described at left (Figure 7). To Replace Filters Remove the air-purifying element from its packaging, and inspect for damage. If in doubt do not use. Check that the air-purifying element has not exceeded its use-by date. Figure 7 Check that the filter connecting thread and gasket are in good condition. Check that the air-purifying element is appropriate to the hazard. If in doubt consult your respirator program administrator or supervisor. Check that the threads in the blower unit port are in good condition and clear of contaminant. Screw the air-purifying elements into the receptacles (see Figure 8) until the cartridge is hand tight. DO NOT OVERTIGHTEN. Check to see that the locking tab is secure (see Figure 9). Locking tab Figure 8 Figure 9 Installing the Spark Arrest Cover If using the HE filter (PN PAPRFC3) and waist belt, then use the EVADCFR1 dust cover and spark arrest cover. Or if using a back pack use the EVABPDCFR1. Another option is to use the PAPRSC2 shower/spark cap to protect the filter and the NMXBTC to protect the breathing tube. Insert the blue mesh disc into the cover, laying the disc against the plastic perforated disc. With the breathing tube attached to the blower but not the helmet, slide the cover down the tube. Then wrap the ends of the cover around the blower and secure with the plastic snaps. The Nomex fabric will protect the breathing tube and the blower while the mesh will protect the HE filter material. Installing and Removing the Belt on the Blower Unit To Install the Belt With the blower filter side down, orient the lever locks as shown in Figure 10. Lay belt over blower as shown in Figure 11. Rotate level locks until they are oriented as shown in Figure 12. To Remove the Belt With the blower filter side down, orient the lever locks as shown in Figure 13. Remove belt from blower. Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 Plastic insert may be removed for cleaning as shown in Figure See back page for more information on cleaning.

17 Donning the Blower and Respirator Initial Donning Prepare to don the blower, battery and hood in a safe, hazard-free area and do the following: Ensure that the filter/cartridges used are suitable for the contaminant in question and are compatible with the EVA1 Blower Unit. Check that the filter/cartridge is properly mounted on the blower unit. Place the battery in the battery compartment on the back of the blower. Fit the blower and belt around the user s waist and adjust the belt for a comfortable fit (suspenders are also available). Remove the belt and blower to install the helmet and corresponding breathing tube. The use of any filter/cartridge not approved with the EVA1 blower unit may put the user at risk and could result in death or serious injury. Connecting the Breathing Tube to the Helmet With the shroud already installed into the helmet, thread the end of the breathing tube that is not already connected to the blower to the threaded port at the rear of the shroud until finger tight. Final Donning: on/off switch Attach the other end of breathing tube to blower unit (if not already attached) by screwing adapters together. Remove any protective film covering the lens of the headpiece. Figure 15 Put on the belt and blower assembly and make any final adjustments to the belt as necessary, keeping the breathing tube and helmet behind the head. Turn the blower on by depressing and holding the on/off switch (Figure 16) for approximately 1 second indicated by a short beep. Buckle the belt onto the waist (blower unit should be in the lower back of the wearer). Don the helmet. Choose speed setting (see below). Place the helmet on the head making any final adjustments to the fit as required at this time to ensure a comfortable and stable fit. Final Donning Do not put on or remove these respirators in a hazardous atmosphere except for emergency escape purposes. Failure to heed these warnings could result in death or serious injury. Donning the Respirator Assembly Buckle the blower with the belt onto the waist with the blower in the lower back of the wearer. Adjust for comfort as preferred. Turn the blower on by depressing and holding the on/off switch (Figure 15) for approximately 1 full second (indicated by a short beep). Don the helmet with shroud. For the SLS1 shroud: Insert your chin into the shroud and pull the helmet upward toward the face. Adjust the drawstring for a snug, but comfortable fit. For the SLS2 shroud: Widen the turtleneck with your hands and insert your head, chin first, then pull onto your head. Adjust drawstring for snug fit. Adjust the ratchet assembly and harness for angle and comfort. Adjust the speed if desired. Do not enter a hazardous area until you are sure that the blower and hood are fully operational and the blower is running. The user should periodically leave the hazardous area to check the airflow through the system. If the low battery or low flow alarm should sound, or if the user experiences any difficulty in breathing, or senses any taste or any odors from the hazard, the user should leave the hazardous area immediately. Failure to observe these warnings could result in death or serious injury. Speed Selection The EVA1 Blower is equipped with the ability for the user to select one of two speeds for operation. When the unit is initially turned on, the blower will operate at approximately 8.5 cfm = 240 lpm (high speed). Note: The battery life is reduced at the higher speed. Pressing the on/off switch will change the speed to approximately 7 cfm = 198 lpm (low speed). Pressing the on/off switch additional times will toggle the unit between the two speeds. Speed change is confirmed by a short beep. Replacing the SLS1 Shroud Remove the old shroud by pulling carefully along the velcro mating line. To install the new shroud, start at the top of the helmet and match the loop sections of Velcro on the shroud to the corresponding hook selections of Velcro on the helmet and secure with pressure.

18 EVA Series Powered Air-Purifying Respirator Blower Assembly User Manual (for use with SparxLift Welding Helmets) Wrap the padded ratchet cover around the ratchet knob and secure the Velcro. Wrap the 5/8 Velcro strips on each side of the ratchet around the headband and secure. Replacing the SLS2 APF Shroud Remove the old shroud by pulling carefully along the velcro mating line. To install the new shroud, start at the top of the helmet and match the loop sections of Velcro on the shroud to the corresponding hook sections of Velcro on the helmet and secure with pressure. Low Battery Alarm and Low Flow Alarm The EVA1 Blower unit is equipped with a Low Battery Alarm and a Low Flow Alarm. The Low Battery Alarm will sound an intermittent 77 dba electronic beep indicating that there are approximately 15 minutes of remaining battery capacity. The delays between beeps will get shorter and shorter as time runs out. The Low Flow Alarm will sound a continuous 77 dba electronic beep indicating that the flow to the hood has dropped below the design specification of 185 lpm = 6.5 CFM (Note: The NIOSH minimum required flow is 170 lpm = 6 CFM). When either of these alarms sounds, the user should immediately do the following: Leave the hazard area Remove the helmet Disconnect the breathing tube from the hood Check the airflow with the airflow indicator (see page 4). Check the operation of the low-flow alarm by blocking the end of the breathing tube. The device will first ramp up to compensate and if correct flow cannot be achieved, the alarm will sound within 5 seconds. Troubleshooting The following guide will assist you in troubleshooting to locate possible issues with your respirator: If the airflow indicator indicates insufficient airflow, the battery should be fully charged (see Battery Pack on page 3), and/or the filter/cartridge should be replaced. The EVA1 blower is provided with a circuit to protect the battery. It will not allow the battery to be discharged below a safe voltage for the cells, regardless of airflow, without the Alarm sounding. When the battery reaches the voltage cutoff it will automatically cease operation. When the Low Battery Alarm sounds and the filter cartridges are not clogged, the battery should be recharged to protect the battery and thereby prolong the working life of the unit. If the ball in the Airflow Indicator is BELOW or PARTLY BELOW the PASS LINE with a fully charged battery, the filter cartridges may need to be changed. Doffing the Respirator Prepare to doff the blower, battery and helmet in a safe, hazard-free area and do the following (in conjunction with your employer s standard operating procedures): Remove the helmet. Turn the blower off by holding down the on/off switch for 5 seconds. This is confirmed by a long beep and a shut down of the motor. Remove the waist belt. Disconnect the helmet from the breathing tube. Disconnect the breathing tube from the blower. Clean and inspect components as necessary. Place battery on charger (as desired). Place components in storage. The use of any filter/cartridge not approved with the EVA1 blower unit may put the user at risk and could result in death or serious injury. Circumstance Possible Cause(s) Solution High Temperature Alarm is sounding High Temperature 122ºF (50ºC) Move to a cooler location Low Battery Alarm is sounding Low Voltage Charge the battery Blower malfunction Return blower for analysis Low Flow Alarm is sounding Clogged/damaged air-purifying filter element Replace the filter/cartridge Battery Low Re-charge the battery Blower malfunction Leave hazardous area immediately and check equipment. If the problem persists and no damage is found, return equipment for repair. Replace breathing tube and/or hood. Hood neck cuff is restricting flow Adjust neck cuff position Smell or taste contaminant Equipment damaged Leave hazardous area immediately and check equipment Non-particulate hazard Select appropriate filter cartridge Low airflow Leave hazardous area immediately and check equipment If the problem persists and no damage is found, return equipment for repair Blower unit does not run full Damaged Battery Return battery for analysis service life Malfunctioning Battery Charger Return charger for analysis Hood neck cuff is restricting flow Adjust neck cuff position

19 MODEL SPARX LIFT RESPIRATOR Approved Only in the Following Configurations: RESPIRATOR COMPONENTS TC- PROTECTION1 HELMET ASSEMBLY ALTERNATE SHROUD ALTERNATE BREATHING TUBES BLOWER UNIT ASSEMBLY FILTER ASSEMBLY BATTERY BELT ASSEMBLY ACCESSORIES CAUTIONS AND LIMITATIONS2 SLH SLS2 SLS1 PAHBT PAHBTXS PAHBTXL PAHBTBK EVA1 PAPRFC3 EVABAT1 EVABELT1 EVABKPK1 EVABELT2 EVASMC EVAEXT1 PA1AFI NMXBTC PAPRSC2 EVAGC PAPRSUSP1 PAPRPF2 EVADCFR1 EVABPDCFR1 EVASMC2 21C-0940 HE X X X X X X X X X X X X X X X X X X X X X X X ABCFHIJLMNOP 21C-0941 HE X X X X X X X X X X X X X X X X X X X X X X X ABCFHIJLMNOP 1. PROTECTION HE = High Efficiency Particulate Air Filter for Powered Air Purifying Respirators 2. CAUTIONS AND LIMITATIONS A. Not for use in atmospheres containing less than 19.5% oxygen. B. Not for use in atmospheres immediately dangerous to life or health. C. Do not exceed maximum use concentrations established by regulatory standards. F. Do not use this respirator if airflow is less than four cfm (115 lpm) for tight-fitting facepieces or six cfm (170 lpm) for hoods and / or helmets. H. Follow established cartridge and canister change schedules or observe ESLI to ensure that cartridges and canisters are replaced before breakthrough occurs. I. Contains electrical parts which have not been evaluated as an ignition source in flammable or explosive atmospheres by MSHA / NIOSH. J. Failure to properly use and maintain this product could result in injury or death. L. Follow the manufacturer s instructions for changing cartridges and / or filters. M. All approved respirators shall be selected, fitted, used and maintained in accordance with MSHA, OSHA and other applicable regulations. N. Never substitute, modify, add or omit parts. Use only exact replacement parts in the configuration specified by the manufacturer. O. Refer to User s Instructions, and/or maintenance manuals for information on use and maintenance of these respirators. P. NIOSH does not evaluate respirators for use as surgical masks.

20 EVA Series Powered Air-Purifying Respirator Blower Assembly User Manual (for use with SparxLift Welding Helmets) PAPR Cleaning Avoid contaminant entry into the breathing tube, as this will compromise respiratory protection and could result in death or serious injury. Consult your local safety professional if you suspect that contaminant has entered the breathing tube. When cleaning the equipment, do the following: Ensure water does not enter filter. Replace wet filter. DO NOT use gasoline, organic-based solvents, or chlorinated degreasing fluids (such as trichloroethylene), as they will cause damage. DO NOT immerse the equipment in water or other cleaning fluid, as this may cause contamination in the breathing tube and blower interior that will be difficult to remove. Use a lint-free cloth moistened in a mild solution of soap and warm water to clean the outer surface of the equipment. Failure to observe the instructions and warnings in this manual invalidates all performance statements and approvals for this equipment and could result in death or serious injury. The following chemicals have been tested and approved as cleaning agents for the blower housing, belt and battery: A. Process NPD (1.256) from Steris B. Spor Klenz (undiluted) from Steris C. Clorox liquid bleach at 10% concentration D. Sani-Cloth HB wipes E. 100% Methanol F. 70% IPA Once filter/cartridges have reached the end of their useful life, discard in accordance with federal, state, and local guidelines, and in conformance with plant safety regulations. PAPR Maintenance DO NOT open the PAPR Housing Assembly. Internal repairs should only be preformed by authorized personnel at the manufacturer s facility. The user should inspect the PAPR before each use. PAPR Storage When the blower is completely dry, store in a clean, dry area, away from direct sunlight and sources of direct heat. The storage temperature should be between 32ºF to 90ºF (0ºC to 32ºC) with humidity less than 90% RH. Instructions for use of the SparxLift Welding Helmet Thank you for purchasing SparxLift welding helmet. For your own protection, safety and to ensure the maximum service life of your new helmet please read this manual carefully before use. Misuse or abuse may result in injury or reduced protection and may also void your warranty. Before Use The auto darkening welding filter in the SparxLift has been designed for arc welding and gas cutting. It is suitable for all normal arc welding processes such as MIG, MAG, TIG, SMAW, Plasma Arc and Air Carbon welding. Before use the shade control should be adjusted to the appropriate level based upon EN169 (European Standard specifications or equivalent) or other appropriate safety guidelines. When in doubt please consult your safety representative or your authorized Bullard distributor. The SparxLift provides continuous protection from ultraviolet and infrared radiation to the maximum level indicated on the product and as described in the relevant Standards. This protection is fail-safe and is not compromised by loss of battery power or other electronic failure. The SparxLift welding filter cartridge is fitted with two independently operated sensors that detect the welding arc and respond accordingly resulting in the appropriate darkened filter state as set by the user and as indicated on the scaled adjustment. Please note that professional judgement may be required to achieve the best results. When in doubt consult an authorized safety representative or your Bullard distributor and always maintain a conservative attitude towards operation. Two replaceable lithium batteries type CR2032 (3V) are used as major power sources. An additional solar cell panel extends battery life and ensures efficient operation. When operating normally the welding helmet will switch on automatically and switch off automatically to save power a few minutes after the last welding arc has been detected. To provide a general check of system status you may wish to set the shade control to 11 and hold the helmet towards a bright incandescent light source. Under normal circumstances the filter will change from light to dark state and back to light state again as you move the helmet away. Please note that if you have any questions or there is any doubt about the performance of your Bullard product you should refer to your authorized safety representative or Bullard distributor. Always use genuine SparxLift front and inside cover plates. Failure to do so may result in injury and will void the warranty. The SparxLift is not designed for overhead welding without the use of additional protection. Check your helmet for physical damage and test it regularly. If your helmet is damaged or is not working normally have it tested and repaired before use. Always select the appropriate shade before use according to the type of welding and current/amperes used. When in doubt refer to your authorized safety representative.

21 Helmet and Head Harness Adjustment Please make the appropriate adjustment(s) to the head harness to ensure a comfortable and secure fit. It only takes a minute and helps ensure you are properly protected. The SparxLift harness allows you to adjust the distance and angle between your eyes and the filter window. You can also adjust the circumference of the headband to ensure a comfortable but firm fit. Please make these adjustments before use based on the illustrations in figures shown below. Markings The appropriate available shade number markings and range are indicated on the product. Please ensure that the appropriate shade number is selected before welding. Used properly the SparxLift provides eye and face protection to meet or exceed EN379 and EN175 and other relevant Standards where indicated. The following example illustrates these requirements. Please note this example is provided for illustration purposes only. Light Shade CE 4 Dark Shade 9-13 Manufacture Identification SERVORE* Optical Class 1 Diffusion of Light Class 1 Variations in Luminous Transmittance Class 1 Certification Mark of Number of Standard 379 *SEVORE manufactures the helmet for Bullard Technical Specifications Switching time (light-dark) 1/25,000(0.04msec) Inactivated Shade #4 Shade Level Activated Shade #9 ~ #13 Sensitivity Adjustment Dual sensors plus pre-shading (Low-High) Switching Delay (dark to light) Adjustable 0.05s 0.8s Tig rating RF(H) >1Amp / RF(L) >10Amp Power supply 3V Lithium battery (CR2032) 2ea (replaceable) Battery life 3000 hours (Approximately) Supplementary power Solar cells (Auto On/Off) Battery replacement Replaceable (Low battery indicator) Cartridge size mm ( in) Filter window 97 46mm ( in) Total weight Autolift : 610g (21.5 oz) Operating temp. -5 C ~ +55 C Storage temp. -20 C ~ +70 C Solar Cell Power Saver The SparxLift solar cell array minimizes battery use by supplying continuous power during welding. The optimized auto on/off power management circuits ensure stable performance and maximum battery life under all conditions. Dual Sensors Plus Pre-Shading Z-Slide cartridges incorporate the latest advances in sensor and preshading technology. By sensing FR and using specially programmed circuits the Z-Slide responds reliably under the most demanding conditions. From Low amp TIG work to simple stick welding, the Z-Slide can be depended upon to respond reliably every time and with the Brilliant Clear X-View screen, welding is now even easier and more enjoyable. Brilliant Clear X-View Technology By incorporating the best optically correct UV and IR filters with special ultra-fast low-distortion LCD panels the SparxLift has made a quantum leap in filter clarity and performance. When combined with the proprietary electronic control technology the results are simply amazing. Blazingly fast, beautifully clear and extremely stable the SparxLift series cartridge sets new industry standards in performance, protection and control. Shade Control The required filter dark state can be selected by using the shade control. The SparxLift can be adjusted between shades 9 to 13 with the embossed arrow on the dial indicating the current adjustment. Always use the appropriate shade for the welding operation you are undertaking. When in doubt please consult the relevant Standards or your authorized safety representative. Recommended shade numbers according to BS 679, DIN and EN169 Welding Process Covered Electrodes MIG on heavy metals Current in amperes MIG light alloys TIG on all metals and alloys MAG Arc-air gouging Plasma jet cutting Microplasma arc welding According to the conditions of use, the next greater or the next smaller scale number can be used.

22 EVA Series Powered Air-Purifying Respirator Blower Assembly User Manual (for use with SparxLift Welding Helmets) Delay Control Control Function The delay functions should be used to set the recovery delay from dark to light of the welding filter according to welding method and current. Maintenance Always ensure that all maintenance procedures are conducted in a clean dry place. Use clean dry hands and avoid direct contact with any glass surfaces. Handle cover plates and welding filter by the edges and carefully clean off any dirt or debris before re-use. Changing the Front and Rear Cover Plates Unclip and open the front cover as shown in the diagram. You will then be able to remove and replace the front cover lens as required. Before installing the new cover lens remove the protective film from both sides. To change the rear cover lens gently remove the cartridge from the helmet you will then be able to unclip the inner cover lens and replace it. Again, you must remove the protective film from both sides of the cover lens before installing it. Parts 1. Solar Cell Panel 2. Sensor 3. LCD Filter Plate 4. Shade Control 5. Delay Control 6. Sensitivity Control 7. RF Sensor Switch 8. Low Battery Indicator Light Sensitivity Control Where problems are encountered during welding at low amps (e.g. TIG) or there is a high level of ambient light please follow these steps. First try adjusting the sensitivity control switch. Start with the sensitivity LOW (gently turn anticlockwise until the knob stops) and adjust upwards as required. If this does not solve the problem, set the sensitivity control in the middle position and hold the helmet close to the target object and adjust the shade control completely clockwise. If the welding filter stays in the light state, leave the control set at this point. If the filter switches to the dark state, turn the shade adjustment back until the filter just switches into the light state. The filter should now be adjusted correctly. If the welding filter still does not respond appropriately, please adjust the sensitivity control again (having previously adjusted the shade control as explained above). [To achieve optimum results in very unusual circumstances you may need to perform this process again having first reset the sensitivity control to low.] RF Sensor Tig Rating New RF High/Low switch for even better RF sensitivity control. Switch to high for extremely low amp TIG(down to 1 amp) or when using shielded cables and welders. Switch to low when working near other welders or in areas of high RF interference to avoid false triggers and for general welding. RF HIGH RF LOW >1 Amp >10 Amp Always use genuine Bullard parts. Never use a welding helmet without both front and rear cover lenses installed. Changing the battery The SparxLift uses two 3V lithium Ion batteries (CR2032) as a main power source. These batteries are user replaceable and should be replaced immediately when the battery warning light comes on and/or at least every three years. Always replace both batteries at the same time with brand new batteries. Never install previously used batteries in your helmet. To replace the batteries slide out the battery holders from either side of the cartridge and discard the old batteries. Install the new batteries in the battery holders and slide the battery holders back into the cartridge. Always note the polarity of the batteries and install them as shown in the diagram and as marked. Batteries rely on good electrical contact to function properly and so always use clean dry hands and avoid getting dirt inside the cartridge when exchanging batteries.

23 Changing the Inner Cover Plate on the SparxLift From inside the helmet unclip the installed cover plate from the shell noting the locking tags on either side of the helmet (see diagram). Remove the film from both sides of the new cover plate and then insert first one side and then the other into the relevant slots on each side of the helmet. Always check to ensure that the locking tags on each side of the helmet are properly mated with the slots in the cover plate and that the four raised guides on the helmet shell are located in the matching slots in the cover plate. Maintaining the Auto Lift assembly on the SparxLift Assembling and disassembling the Auto Lift assembly on the SparxLift is a simple process but should be done according to the following instructions to ensure problem free operation of the helmet. Locate the spring (10-3L) in the recess on the outside of the helmet shell ensuring that the end of the spring is hooked into the hole provided and pointing upwards. Springs are handed (R/L) and if reversed the Auto Lift mechanism will not work. Place the spring retainer (10-2L) over the spring and ensure that the tongue of the retainer is located in the slot provided on the side of the helmet shell. Mount the cartridge holder assembly over the spring retainer ensuring that the notches in the top of the spring retainer are nested into the matching slots on the cartridge holder assembly. Insert the slotted bolt into the hole and over the end of the spring. While holding the slotted bolt in place with your thumb, look inside the shell and locate the black washer over the end of the bolt which should now be visible on the inside of the shell. Note that the black washer has internal fins that mate with the end of the slotted bolt. Insert the self tapping screw into the washer and screw it in. Avoid over-tightening. Use a coin to tension the springs on each side by turning the head of the slotted bolts with a coin. Avoid over tensioning. Test the Auto Lift mechanism after each adjustment. Usually turning the screw a few clicks or about 180 degrees gives perfect results. Storage and Temperature Range Your Bullard welding helmet is strong and durable. It is designed to work in temperatures between -5C and +55C. Do not use your helmet in very hot conditions where temperatures exceed +65C. Always store your helmet in a clean dry place out of the direct sun and protect it from exposure to moisture or extreme heat (min/max storage temperature is -20C ~ +70C). Avoid unnecessary impact or compression of your helmet and never use a helmet that is damaged. Your Bullard welding helmet is a quality professional tool and careful storage will extend the life of your investment. Inspection Check your helmet shell and filter on a regular basis when in normal use and after extended periods of storage. Never use a cracked or damaged helmet as this may result in personal injury and will void your warranty. Please replace any worn or damaged parts as necessary. Genuine Bullard replacement parts are available from your authorized Bullard distributor. Cleaning Never expose the filter cartridge to direct contact with water or solvents. After removing the welding filter from the shell the shell can be cleaned using a mild detergent and water solution. Sweat bands can be washed. A silicone based lubricant may be used on moving parts if necessary but is not normally required. The filter may be carefully wiped with a cloth dampened with household window cleaning solution. Please be careful not to scratch or otherwise damage the filter cartridge with fragments of welding spatter or other abrasive dirt. Refer to the relevant parts diagram for illustrations regarding assembly and disassembly.

24 EVA Series Powered Air-Purifying Respirator Blower Assembly User Manual (for use with SparxLift Welding Helmets) CAUTIONS The SparxLift is designed for personal eye and face protection from harmful radiation, sparks and welding spatter produced under normal welding conditions. Please follow good industry and safety practices and use additional protection where necessary. Cover plates are strong and of industry standard quality but they are breakable. The SparxLift is a quality welding helmet but is not designed to provide protection from severe impact such as broken grinding wheels or debris from other broken tools, corrosive liquids, explosions, or other extreme incidents. We recommend you always adopt a conservative attitude towards safety and take additional precautions as required and recommended in the relevant safety standards relating to the operation you are undertaking. The welding filter is not designed to be waterproof. Please do not use your helmet in the rain or other inclement weather. To do so may reduce the life of your helmet and result in damage or injury. In the event that your helmet or welding filter is exposed to direct contact with, or is submerged in water or other liquid immediately stop using the helmet, remove the filter cartridge from the shell, remove the batteries from the filter, inspect carefully for damage and if necessary mop-up excess moisture with a paper towel and then leave to dry in a warm (not hot) place out of direct sunlight. Never place your helmet in an oven or microwave to dry. Before use perform all normal system checks and if in any doubt contact your Bullard distributor. Your Bullard helmet is a precision engineered professional protection product and must be maintained in good condition to ensure your personal protection. When working in the vicinity of other welders it is necessary to adopt good industry standard practice and ensure a minimum distance of 1M between workers. Failure to do so may result in injury or malfunction of the auto darkening mechanism. Please do not wear the helmet when you are not welding. In some circumstances the auto darkening mechanism may be unexpectedly triggered resulting in reduced vision and subsequent injury to yourself or others. Bullard does not support the use of SparxLift range of products in combination with any other manufacturers products. To use parts that are not approved by Bullard may void your warranty and result in personal injury. Please use only genuine SparxLift parts and spares as provided by your authorized Bullard distributor. Bullard reserves the right to make improvements, change or otherwise modify the specifications, materials and design of any and all Bullard products at their sole discretion with a view to ensuring continuous improvement. Never attempt any unauthorized modifications or alterations to your Bullard product. To do so may result in personal injury and void your warranty. Thank you for purchasing a Bullard product. If you have any questions regarding this or any other Bullard product please contact your authorized Bullard distributor.

25 Ordering Information Respirator Assemblies (includes blower, battery, charger, breathing tube, breathing tube cover, spark arrest cover, helmet, shroud, and HE filter) EVASLS1 EVASLS2 Blower Assemblies EVA1 EVA2 EVA3 Replacement Batteries and Chargers EVABAT1 EVASMC EVASMC2 EVAGC Replacement Filter Cartridges PAPRFC3 Replacement Shrouds SLS1 SLS2 Loose-Fitting Facepiece Shroud System Hood Style Shroud System Blower Unit Only Blower Unit, Battery, and Charger Blower Unit, Battery, Charger, and HE filter Lithium Polymer Battery Back (black) Single Port Charger Single Port Analyzing Charger Six Port Gang Charger HE Particulate Filter (6 per box) Loose-Fitting Facepiece Shroud Hood Style Shroud Replacement Breathing Tubes and Covers PAHBT PAHBTXS PAHBTXL PAHBTBK EVADCFR1 EVABPDCFRI NMXBTC Powered Air Hood Breathing Tube Assembly (standard length) Powered Air Hood Breathing Tube Assembly (short length) Powered Air Hood Breathing Tube Assembly (long length) Powered Air Hood Breathing Tube Assembly for Back Pack Spark Arrest/Dust Cover, Fire Retardant for use with PAPRFC3 Spark Arrest/Dust Cover, Fire-Retardant for use with Back Pack and PAPRFC3 Nomex Breathing Tube Cover Replacement Belts, Back Packs, and Suspenders EVABELT1 EVABELT2 EVAEXT1 PAPRSUSP1 EVABKPK1 Replacement Air Flow Indicator PA1AFI Replacement Welding Helmet Parts Foam Closed Cell Comfort Bell Urethane Decon Belt Belt Extenders Suspenders Back Pack Air Flow Indicator, Rotometer 1. SLSHELLBLU Helmet Shell, does not include harness or knob set 2. SLGL Inner Protective Lens (Grinding), 3 pack 3. SLRCL Inside Cover Plate, 5 pack 4. SLADF Auto Darkening Filter 5. SLPBA Push Button Assembly 6. SLHCA Hinge Cap Assembly 7. SLHG Head Gear (including harness and knob set) 8. SLBAT1 Battery 9. SLCLP Lens Cover Pack (five front lenses, two inner lenses) 10. SLFCL Front Cover Lens, 10 pack Exploded View Diagram

26 EVA Series Powered Air-Purifying Respirator Blower Assembly User Manual (Incorporating the Bullard FAMB Series Half Face Mask) Powered Air-Purifying Respirator with High Efficiency (HE) Filters Approval No. TC-21C-0846 Powered Air-Purifying Respirator with OV-AG-HE Filter Cartridges for organic vapors, chlorine, hydrogen chloride, sulfur dioxide, chlorine dioxide, hydrogen fluoride and particulates Approval No. TC-23C-2511 Cautions and Limitations A. Not for use in atmospheres containing less than 19.5% oxygen. B. Not for use in atmospheres immediately dangerous to life or health. C. Do not exceed maximum use concentrations established by regulatory standards. F. Do not use respirator if airflow is less than four cfm (115 lpm) for tight fitting face pieces or six cfm (170 lpm) for hoods and/or helmets. I. Contains electrical parts that may cause an ignition in flammable or explosive atmospheres. J. Failure to properly use and maintain this product could result in injury or death. L. Follow the manufacturer s user instructions for changing cartridges and/ or filters. M. All approved respirators shall be selected, fitted, used and maintained in accordance with MSHA, OSHA and other applicable regulations. N. Never substitute, modify, add or omit parts. Use only exact Bullard replacement parts in the configuration as specified by the manufacturer. O. Refer to User s Instructions and/or maintenance manuals for information on use and maintenance of these respirators. P. NIOSH does not evaluate respirators for use as surgical masks. Use strictly in accordance with instructions, labels and limitations pertaining to the EVA Series respirator. 1. The EVA Series respirator does not supply oxygen. Use only in adequately ventilated areas containing at least 19.5% oxygen. 2. Do not use when concentrations of contaminants are immediately dangerous to life or health (IDLH). This term is defined in 29CFR (b). 3. Do not use these respirators for respiratory protection during abrasive blasting or clean up. 4. Do not use in circumstances where the airborne concentration level of contaminant exceeds maximum use concentration for this type of respirator as established by regulatory standards. 5. Leave area immediately if: Breathing becomes difficult Dizziness or other distress occurs You taste or smell the contaminant Unit becomes damaged Battery alarm activates Low Flow alarm activates 6. This apparatus must not be worn with the blower unit switched off. If the blower is switched off, a rapid build-up of carbon dioxide and depletion of oxygen may occur, which could result in death or serious injury. 7. Never alter or modify this respirator. Use only Bullard NIOSH-approved EVA Series components and replacement parts for this respirator. 8. This device is not immune to highly powered RFI/EMI emissions. Failure to follow these warnings could result in death or serious injury.

27 EVA Series - Principle of Operation The EVA Series Powered Air-Purifying Respirator (PAPR) System is configured in six parts: 1. The blower and belt assembly: EVA1 Blower Unit EVABELT1 Comfort/Decon Belt PA4AFI Air Flow Indicator (sold separately) 2. The battery pack (Part No. EVABAT2). One fully charged pack will power the blower for approximately four to six hours depending upon factors such as speed, cartridge selected and cartridge loading. The EVABAT2 is green and is not for use with Loose Fitting Hoods or Loose Fitting Face Pieces. 3. The PAFAMBT Mask breathing tube assembly (standard length) 4. The High Efficiency Particulate Absolute (HEPA) filter. 5. The Half Face Mask: The following models may be used with the EVA Series blower unit: FAM2S (Small) FAM2M (Medium) FAM2L (Large) 6. The Battery Charger: EVASMC Quick charger EVAGC Gang charger The blower unit draws in ambient air through the cartridge. The purified air is blown into the wearer s mask through the breathing tube. A flow indicator is provided to check that there is an adequate volume of air available to the wearer prior to use. The system is designed to operate at a minimum air flow of approximately 4.5 cubic feet of air per minute (128 liters per minute) in the mask under normal use on the standard speed setting, and 5 cubic feet of air per minute (142 liters per minute) in the mask under normal use on the high speed setting. A feedback loop from the Mass Flow Sensor to the impellor continually monitors and adjusts the air flow to keep it constant at the design set point. The units are designed for use at temperatures from 10ºF to 120ºF (-12ºC to 49ºC). The battery pack mounts in a compartment on the back of the blower. A fully charged battery pack will power the blower for approximately four to six hours depending upon factors such as speed selected, cartridge selected, and filter/ cartridge loading. The EVA Series Blower is equipped with two alarms: A 77 db continuous alarm will sound when the air flow reaches approximately 115 lpm and a 77db intermittent chirp alarm will activate to indicate that the battery has approximately 15 minutes of remaining capacity. Type C Airline Respirators The FAMB Half Face Mask used with the EVA PAPR can also be configured for use in Supplied Air Configurations. Refer to the FAMB Series Supplied Air Respirator User Instructions for details. Battery Pack One fully charged battery pack will power the blower for approximately four to six hours depending upon factors such as speed selected, cartridge selected and filer/cartridge loading. The battery has built-in short circuit protection. In the event of a short circuit, an internal polyfuse will trip. The fuse will reset itself within 5-10 seconds allowing the battery to resume normal operation. To charge the battery pack, do the following: Press the battery release on the pack to remove the battery from the back of the blower. (See Figure 1.) Place battery upside down into the charging port of the battery charger. (See Figure 2.) Connect the battery charger to a 110-volt AC electrical outlet. Charge the battery pack for approximately four hours. Battery release Figure 1 Figure 2 While the battery is charging, the light on the charger will remain red. The charger light will illuminate green when charging is complete. Table-top gang chargers EVAGC with 6 ports are also available. Diagnostic functions are available for chargers (upon special order) including access to data such as number of cycles of operation, remaining charge capacity, etc. Details for these functions are available in the charger user manual (upon special order).

28 EVA Series Powered Air-Purifying Respirator Blower Assembly User Manual (Incorporating the Bullard FAMB Series Half Face Mask) DO NOT charge batteries in hazardous areas. Battery Storage Storage of Li Polymer batteries is relatively easy. Unlike Nickel batteries, they lose a very small amount of power (less than 0.5% per day) and therefore can be charged and stored ready for use. If long-term storage is required, it is best to store the battery in a cool place with at least 40% charge still remaining. Discharging and re-charging the battery fully at least once every 3 months is suggested to ensure the longest possible life of the battery. Temperature 40% charge level 100% charge level (recommended storage (typical user charge level) charge level) 0ºC 98% after 1 year 94% after 1 year 25ºC 96% after 1 year 80% after 1 year 40ºC 85% after 1 year 65% after 1 year 60ºC 75% after 1 year 60% after 3 months To maximize battery life, these guidelines should be followed: Remove the battery from the blower unit when not in use. Charge the battery before it is completely discharged. The low battery alarm indicates that the battery needs to be charged. The battery is designed with a circuit to protect the battery. It will not allow the battery to be discharged below a safe voltage for the cells, regardless of airflow, without the alarm sounding. When the battery reaches the voltage cutoff it will automatically cease operation. Always charge the batteries at room temperature or cooler. At higher temperatures, the battery pack may not accept a full charge. If the battery pack feels hot, let it cool for 30 minutes before charging. Do not charge battery packs in an enclosed cabinet without ventilation. Battery capacity may be checked with a diagnostic charger (special order). Table-top gang chargers (Part No. EVAGC with 6 ports) are also available. Battery Fuel Gauge: EVA Battery Packs are equipped with an on-board fuel gauge to indicate the amount of remaining capacity left in the battery pack. To check the remaining capacity, simply depress the button Figure 3 labeled Push and LEDs will illuminate indicating the level of battery capacity remaining. When fully charged all four LEDs will illuminate green, and when 25% or less charge is available a single LED will illuminate red. Pre-Operational Inspection Prior to each work shift, perform the following Pre-Operational Inspection to ensure proper operation and to ensure that the unit is completely assembled. 1. Belt Mounted Blower Unit, Part No. EVA1 Check that the unit is clean and undamaged. Inspect for deterioration, physical damage and improper assembly. 2. Filter/Cartridges Inspect the filter/cartridge for any physical damage Check the label to ensure the filter/cartridge has not exceeded its use-by date. Inspect the gasket on the filter for any physical damage. Each filter comes with a permanent gasket. Ensure that the correct filter/cartridge is appropriate for the contaminant. Consult the NIOSH approval label and your own in-plant safety professional if you have any questions as to the suitability and efficiency of the Air-Purifying Element. Screw the cartridge into the port until handtight and the locking tab is secure. (Refer to Mounting and Replacing Filters on Blower Unit on page 5) 3. Battery Pack The EVABAT2 is green and is not for use with Loose Fitting Hoods or Loose Fitting Face Pieces. Figure 4 Check that the battery is not damaged. Check the Fuel Gauge to determine sufficient charge is available. Place the battery pack in the battery compartment on the blower. The battery tab should click when completely engaged. (See Figure 4) 4. Half Face Mask and Breathing Tube Inspect the full face mask for any physical damage, such as torn head harness straps, scratched or cracked visor and distortion of the rubber flange. Inspect the breathing tube for tears, cracks, holes or excessive wear that might reduce the degree of protection originally provided. Replace any damaged parts with the proper Bullard replacement part to maintain the NIOSH approval. Mounting the Breathing Tube on the Blower Ensure that a rubber gasket is in place in the breathing tube coupler on the blower unit. Screw one end of the breathing tube into the blower unit. (Hand tight is sufficient.) (See Figure 5). Ensure that neither the breathing tube nor the filter is blocked. Ensure that the ON/OFF Switch is in the OFF position. Switch on the blower by pressing the on/off button for 1-2 seconds confirmed by a short beep. If the Low Battery Alarm sounds at this time, the battery needs to be recharged. See instructions on page 2 regarding properly charging the battery. If the Low Flow Alarm sounds after the Figure 5 blower reaches full speed, then the mask, breathing tube and filter should be check for a blockage.

29 Checking Airflow with the Airflow Indicator (PA4AFI - sold separately) With the blower switched ON and the filters/ cartridges mounted, take the free end of the breathing tube in one hand, hold it upright and place the Airflow Indicator into the end of the tube. (See Figure 6). Apply a light downward pressure to the Airflow Indicator to get a reasonable seal at the breathing tube end. Ensure that the air outlet holes in the Airflow Indicator tube are not blocked. Two hands may be used if preferred, one to hold the breathing tube and one to hold the Airflow Indicator. Figure 6 The position of the ball in the Airflow Indicator should be observed. If any part of the ball is below the PASS LINE on the Airflow Indicator, check for: Blower malfunction. Clogged or damaged Air-Purifying filter elements on the HE filter. See Mounting and Replacing Cartridges on the Blower Unit on page 7. Low battery or battery malfunction. If the ball is completely above the PASS LINE on the Airflow Indicator, then the system is ready for use. If the blower malfunctions during use in a hazardous area: Remain calm and LEAVE the hazardous area immediately. DO NOT use a blower that fails the flow test (air flow indicator sold separately). Use ONLY Bullard filter/cartridges which comply with and have the NIOSH approval label and which are appropriate for the contaminant. Failure to observe these warnings could result in death or serious injury. EVA Series PAPR Air-Purifying Elements Principle of Operation The following filter/cartridge protection classification applies when used with any EVA PAPR system. NIOSH / ANSI Color Protection Filter/Cartridge Type Code for Cartridge Label HE PAPRFC3 Magenta OV/CL/HC/ PAPRFC4 Olive and Magenta SD/CD/HF/HE HE particulate filters are 99.97% effective against all particulate aerosols. Filters are supplied in quantities of six per box. The following abbreviations are approved by NIOSH to indicate the particulates, gases, or vapors which are removed by the gas/vapor cartridges: HE High Efficiency Particulate Air Filter for Powered Air-Purifying Respirators Use only the filter/cartridge(s) described in the above table. Do not change cartridges while in a hazardous atmosphere. Incorrect cartridge selection will invalidate all performance statements and approvals for this equipment. Follow established cartridge change schedules to ensure that cartridges are replaced before breakthrough occurs. Failure to follow these warnings could result in death or serious injury. Mounting and Replacing Filters on the Blower Unit High efficiency particulate filters must be replaced when retained particles clog the filters and reduce air flow below acceptable levels, as indicated by testing with the Air Flow Indicator as described at left. Figure 7 To Replace Filters Remove the air-purifying element from its packaging, and inspect for damage. If in doubt do not use. Check that the air-purifying element has not exceeded its use-by date. Check that the filter connecting thread and gasket are in good condition. Check that the air-purifying element is appropriate to the hazard. If in doubt consult your respirator program administrator or supervisor. Check that the threads in the blower unit port are in good condition and clear of contaminant. Screw the air-purifying elements into the receptacles (see Figure 8) until the cartridge is hand tight. DO NOT OVERTIGHTEN. Check to see that the locking tab is secure. (see Figure 9) To Replace Combination Filter/Cartridge Follow the steps above, but beware that the filter locking tab is beneath the filter rim. (see Figure 10) Locking tab Locking tab Figure 8 Figure 9 Figure 10 Installing and Removing the Belt on the Blower Unit To install the belt With the blower filter side down, orient the lever locks as shown in Figure 11 Lay belt over blower as shown in Figure 12 Rotate level locks until they are oriented as shown in Figure 13 Figure 11 Figure 12 Figure 13 To Remove the Belt With the blower filter side down, orient the lever locks as shown in Figure 12 Remove belt from blower

30 EVA Series Powered Air-Purifying Respirator Blower Assembly User Manual (Incorporating the Bullard FAMB Series Half Face Mask) Plastic insert may be removed for cleaning as shown in Figure See back page for more information on cleaning. Figure 13 Figure 14 Donning the Blower and Respirator Initial Donning Prepare to don the blower, battery and facepiece in a safe, hazard-free area and do the following: Ensure that the cartridge used is suitable for the contaminant in question and is compatible with the EVA Blower Unit. The use of any filter/cartridge not approved with the EVA blower units may put the user at risk and could result in death or serious injury. Check that the cartridge is properly mounted on the blower unit. Prior to assembling the system, place the battery in the battery compartment on the back of the blower. Fit the blower and belt around the user s waist. With the blower at the rear of the user, adjust the belt for a comfortable fit. Remove the belt and blower. Screw the breathing tube into the mask inlet until tight. (See Figure 15) Place the plastic headband straps on your head so the top plastic strap rests across the top your head and the bottom plastic strap rests above your ears on the back of your head. Then hook the bottom elastic headband straps behind your neck and below your ears. Adjust the position of the facepiece on your face for a comfortable fit. If the elastic straps are too tight or too loose then remove the respirator from your face and adjust. Do not over-tighten as it may distort the mask and cause Figure 16 leakage. Perform a negative pressure seal check: A) With mask on and secured, place the palm of your hand over the end of the air entry B) Inhale until the mask collapses inward Figure 17 slightly (indicating there is a negative pressure). Hold your breath for five seconds. C) The mask is deemed to be in proper position if it remained collapsed while the breath was being held and no inward leakage of outside air is detected. D) If mask doesn t collapse or if an inward leak is detected, re-adjust mask on face and repeat above steps until the test is passed. Persons wearing tight fitting masks, such as the FAMB series, are required by OSHA to be fit tested before initial use and at least annually thereafter. Seal checks are to be performed before each use. If you cannot attain a proper fit test and seal, try another mask size and repeat the steps outline previously. If a proper fit and seal is still not achieved do not use the respirator. Turn on the blower, and attach the breathing tube to the blower. With the air flowing into your respirator, you are now ready to enter the work area. Donning the FAMB Mask Figure 15 Warning Do not wear the EVA half mask PAPR if facial hair is present that comes between the sealing surface of the facepiece and the face, or that interferes with valve function. Failure to follow these instructions could result in death or serious injury. Loosen the mask s elastic straps. Grasp the front of the facepiece with one hand and the upper strap with the other hand. Position the respirator on your face so that the inside portion of the facepiece is under your chin and the narrow portion of the facepiece is over your nose. Figure 18 The mask over must be used when operating this respirator. This part protects the exhalation valve from outside interference. Failure to follow these instructions could result in death or serious injury.

EVAHL Series Hazardous Location Powered Air-Purifying Respirator User Manual Cautions and Limitations

EVAHL Series Hazardous Location Powered Air-Purifying Respirator User Manual Cautions and Limitations EVAHL Series Hazardous Location Powered Air-Purifying Respirator User Manual (for use with Loose-Fitting Headtops) EVAHL1 - Powered Air-Purifying Respirator Powered Air-Purifying Respirator with High Efficiency

More information

GR50 Airline Respirator

GR50 Airline Respirator GR50 Airline Respirator Enhanced comfort and Protection for Grinding Operations Offering both respiratory and dermal protection, Bullard s GR50 is the first hood-style airline respirator designed especially

More information

CC20 Series Airline Respirator Selection Chart 1. Choose Head Top

CC20 Series Airline Respirator Selection Chart 1. Choose Head Top Selection Chart 1. Choose Head Top 20TJN - Tychem QC Single Bib Hood 20TPN - With Solvent- Resistant Lens 20TICN - Tychem QC Double Bib Hood 20TPCN - With Solvent- Resistant Lens 20SICN - Tychem SL Double

More information

Respiratory Protection and Air Quality Products

Respiratory Protection and Air Quality Products Respiratory Protection and Air Quality Products Blasting and Grinding Painting and Powder Coating Clean Room Applications Pharmaceutical Manufacturing Infection Control Hospital Preparedness Chemical Handling

More information

Powered Air Purifying Respirator (PAPR) For Departments that Store, Supply and Maintain PAPR Units

Powered Air Purifying Respirator (PAPR) For Departments that Store, Supply and Maintain PAPR Units Powered Air Purifying Respirator (PAPR) For Departments that Store, Supply and Maintain PAPR Units Warning: Read the printed User Instructions provided with each PAPR system before use. The User Instructions

More information

CF60 General Information

CF60 General Information CF60 General Information Global Secure CF60 Developed to protect health-care workers, the Global Secure CF60 is an ideal powered-air purifying respirator (PAPR) for use in infection control and to protect

More information

Powered Air Purifying Respirator (PAPR) System

Powered Air Purifying Respirator (PAPR) System Powered Air Purifying Respirator (PAPR) System IMPORTANT NOTICE Please read these instructions carefully before using this unit. Failure to comply with the instructions may void your warranty and adversely

More information

SR 500 POWERED AIR-PURIFYING RESPIRATOR. Features. - Lightweight, balanced and ergonomic design. - Ergonomic comfort belt.

SR 500 POWERED AIR-PURIFYING RESPIRATOR. Features. - Lightweight, balanced and ergonomic design. - Ergonomic comfort belt. SR 500 POWERED AIR-PURIFYING RESPIRATOR Features - Lightweight, balanced and ergonomic design - Ergonomic comfort belt - Dual flow rates - Easy to adjust and maintain - Automatic setting of flow rate and

More information

PureLite XStream. Self-Contained Powered Air Purifying Visor System. User Manual

PureLite XStream. Self-Contained Powered Air Purifying Visor System. User Manual PureLite XStream Self-Contained Powered Air Purifying Visor System User Manual This product is covered by one or more patents. For more information visit www.gentexcorp.com/patents 414607 TABLE OF CONTENTS

More information

Lightweight protection with safety at the forefront

Lightweight protection with safety at the forefront Lightweight protection with safety at the forefront As you know, protecting your employees can be expensive. How can you ensure your workers are safe without significant additional expense to the company?

More information

TRAINING PROGRAM CUFF SYSTEM

TRAINING PROGRAM CUFF SYSTEM TRAINING PROGRAM CUFF SYSTEM 2 INDEX Warnings and Cautions 3 CAPR Introduction 6 System Configuration Basics SnapOn Cage Removal Filter Cartridge Assembly Filter Cover Cap Assembly Helmet Liner Instillation

More information

PAPRV. Powered Air Purifying Respirator (PAPR) System. Please read these instructions carefully before using this unit. affect your health and safety.

PAPRV. Powered Air Purifying Respirator (PAPR) System. Please read these instructions carefully before using this unit. affect your health and safety. Warranty: The blower unit is guaranteed for a period of 12 months from date of purchase against mechanical or electrical defects. The battery is guaranteed for a period of 6 months from the date of purchase.

More information

Table of Contents for Powered and Supplied Air Matrices

Table of Contents for Powered and Supplied Air Matrices Table of Contents for Powered and Matrices 3M Air-Mate High Efficiency (HE) Belt-Mounted Powered Air Purifying Respirator Systems 3M Breathe Easy Belt-Mounted PAPR System with BP-17IS NiCD Battery (Intrinsically

More information

RESPIRATORY CATALOG. The SR 500. PAPR family. The AirPlus. PAPR family

RESPIRATORY CATALOG. The SR 500. PAPR family. The AirPlus. PAPR family RESPIRATORY CATALOG 2018 The SR 500 PAPR family prevents pollutants, gases, vapors & particulates from penetrating the breathing zone. The AirPlus PAPR family also supplies fresh filtered air, keeping

More information

SR500 PAPR How to Copyright 2015 by The S.E.A. Group 1

SR500 PAPR How to Copyright 2015 by The S.E.A. Group 1 SR500 PAPR How to Copyright 2015 by The S.E.A. Group 1 BEFORE YOU START: Make sure the respirator and all its parts are clean and intact Make sure you are familiar with the equipment and know how to use

More information

JETSTREAM & JETSTREAM GV-X

JETSTREAM & JETSTREAM GV-X JETSTREAM & JETSTREAM GV-X EN12941 : 1998 RESPIRATORY PROTECTIVE DEVICE - POWERED FILTERING DEVICE, INCORPORATING A HELMET OR HOOD, CLASS TH2 DEVICE USER INSTRUCTION MANUAL IMPORTANT - This manual must

More information

0194 INSTRUCTION MANUAL

0194 INSTRUCTION MANUAL 0194 INSTRUCTION MANUAL CONTENTS Read all instructions and warnings before using this product. Keep this manual for future reference. INTRODUCTION 3 PAPR COMPONENT CONCEPT 5 WARNINGS 6 RESPIRATOR OPERATIONS

More information

SparxLift Welding PAPR. Features & Benefits April 2014

SparxLift Welding PAPR. Features & Benefits April 2014 SparxLift Welding PAPR Features & Benefits April 2014 1 Key Specifications - Helmet Regulatory Standards Helmet Weight (without shroud) ANSI/ISEA Z87.1-2010 (High Impact) EN175 and EN379 560 grams (19.6

More information

Adjustable Radical Face Protector Owners Guide

Adjustable Radical Face Protector Owners Guide Adjustable Radical Face Protector Owners Guide Model 40VIZI2 and 40VIZI4! This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow

More information

SUNC3000 / Item #40885

SUNC3000 / Item #40885 SUNC3000 / Item #40885 AUTOMATIC POOL COVER PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM 1 . Performance GPH of Water @ Total Feet Of Lift MODEL HP Max. Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. SUNC3000 1/3

More information

Work. 3M Versaflo Respirator Systems. Highly Versatile Systems for Respiratory Protection

Work. 3M Versaflo Respirator Systems. Highly Versatile Systems for Respiratory Protection Respirator Systems Work Highly Versatile Systems for Respiratory Protection Respirator Systems are a comfortable, comprehensive approach to worker protection. Each system has three easy-to-select modules

More information

Empowering the Best APR to PAPR

Empowering the Best APR to PAPR Empowering the Best APR to PAPR North introduces the NEW COMPACT AIR TM Powered Air-Purifying Respirators CA101 Loose Fitting Blower/Battery Bringing you more More Versatility Convert your North half mask

More information

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM Performance Model HP GPH of Water @ Total Feet Of Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. 25 ft. Max. Lift SUNC1200

More information

Advanced protective headgear. Applied to making work more comfortable. 3M Versaflo M-Series Headgear for Powered and Supplied Air Respirators

Advanced protective headgear. Applied to making work more comfortable. 3M Versaflo M-Series Headgear for Powered and Supplied Air Respirators Advanced protective headgear. Applied to making work more comfortable. 3M Versaflo M-Series Headgear for Powered and Supplied Air Respirators 3M.com/Versaflo 2 Dependable protection, exceptional comfort

More information

Nilfisk-CFM SS Vapor Vacuum Instructions for Use and Spare Parts Manual

Nilfisk-CFM SS Vapor Vacuum Instructions for Use and Spare Parts Manual Nilfisk-CFM SS Vapor Vacuum Instructions for Use and Spare Parts Manual Caution: This Nilfisk-CFM vacuum cleaner is not to be used in explosion hazardous areas as serious injury could result. Your new

More information

TABLE OF CONTENTS SECTION 1 PAPR SAFETY PRECAUTIONS READ BEFORE USING...

TABLE OF CONTENTS SECTION 1 PAPR SAFETY PRECAUTIONS READ BEFORE USING... TABLE OF CONTENTS SECTION PAPR SAFETY PRECAUTIONS READ BEFORE USING... -. Symbol Usage... -2. Arc Welding Hazards... -3. Lens Shade Selection Table... 4-4. Proposition 65 Warnings... 4-5. Principal Safety

More information

40041 Heavy Duty ADA System with Booster Bracket for JK Heavy Duty ADA System with Booster Bracket for 2012 to Current JK

40041 Heavy Duty ADA System with Booster Bracket for JK Heavy Duty ADA System with Booster Bracket for 2012 to Current JK 40041 Heavy Duty ADA System with Booster Bracket for 2007-2011 JK 40044 Heavy Duty ADA System with Booster Bracket for 2012 to Current JK 40049 Heavy Duty ADA System Universal for all vehicles (booster

More information

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by: Storage System Ultrasound Probe Cabinet Operator's Manual Manufactured by: CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA 319.248.6757 / 800.445.6741 WWW.CIVCO.COM Copyright 2018 All

More information

Inspection, Cleaning, and Storage Procedures for 3M Versaflo TR-800 PAPR Assemblies

Inspection, Cleaning, and Storage Procedures for 3M Versaflo TR-800 PAPR Assemblies 3M Product Name Technical Bulletin Release 1, May 2018 Inspection, Cleaning, and Storage Procedures for 3M Versaflo TR-800 PAPR Assemblies Introduction The 3M Versaflo TR-800 Powered Air Purifying Respirator

More information

Powered Air-Purifying Respirator (PAPR)

Powered Air-Purifying Respirator (PAPR) OM-35 936 Rev. K 04 05 Description Powered Air-Purifying Respirator Powered Air-Purifying Respirator (PAPR) To help us serve you better, go to www.millerwelds.com/register File: Accessory Visit our website

More information

silica EYE PROTECTION... page 2 HEARING PROTECTION... page 2 PAPR & DISPOSABLE RESPIRATORS... page 3 4 COVERALLS... page 5 HEPA VAC...

silica EYE PROTECTION... page 2 HEARING PROTECTION... page 2 PAPR & DISPOSABLE RESPIRATORS... page 3 4 COVERALLS... page 5 HEPA VAC... silica EYE PROTECTION... page 2 HEARING PROTECTION... page 2 PAPR & DISPOSABLE RESPIRATORS... page 3 4 COVERALLS... page 5 HEPA VAC... page 5 800.632.2955 2.19 Powered Air Purifying Respirators CleanSpace2

More information

ICAN INTELLIGENT AIR FLOW DEVICE

ICAN INTELLIGENT AIR FLOW DEVICE ICAN INTELLIGENT AIR FLOW DEVICE 70-200 1 IMPORTANT INSTRUCTIONS ICAN INTELLIGENT AIR FLOW DEVICE 70-200 Content page Important instructions 1 General 2 Application / Limitation / Filters 3 Head product

More information

spirit POWERED AIR RESPIRATOR

spirit POWERED AIR RESPIRATOR spirit POWERED AIR RESPIRATOR advanced CONtrolability comprehensive protection spirit Intelligent and adaptable powered air respiratory system from Scott Safety Introducing the next generation of powered

More information

RESPIRATORY PRODUCT OVERVIEW

RESPIRATORY PRODUCT OVERVIEW RESPIRATORY PRODUCT OVERVIEW DISPOSABLE DUAL CARTRIDGE RESPIRATOR 01 Disposable Dual Cartridge Respirator Pre-assembled respirator eliminates cartridge and fi lter attachment hassles Face piece is constructed

More information

1. Revise and A to read as follows:

1. Revise and A to read as follows: NFPA 1984-2011 Respirators for Wildland Fire Fighting Operations TIA Log No. 1017 Reference: 4.1.2, A.4.1.2, 6.1.2, 7.1.8, 7.2, 7.3, and Chapter 8 Comment Closing Date: January 21, 2011 Submitter: Heinz

More information

LESTRONIC II BATTERY CHARGER MODEL 19740

LESTRONIC II BATTERY CHARGER MODEL 19740 *01679* LESTRONIC II BATTERY CHARGER MODEL 19740 PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING INSTRUCTIONS For correct operation of the equipment, it is important to read and be familiar with this

More information

OptimAir 6A PAPR with OptiFilter Cartridges

OptimAir 6A PAPR with OptiFilter Cartridges OptimAir 6A PAPR with OptiFilter Cartridges Features Can be used with an entire family of filters and combination cartridges for protection against particulates, toxic gases and vapors Belt-mounted motor/blower

More information

User s Manual for Tennessee Chill Box System P/N CB8000

User s Manual for Tennessee Chill Box System P/N CB8000 User s Manual for Tennessee Chill Box System P/N CB8000 Read and understand all instructions before using this product. Open carton carefully and inspect product for damage caused by carrier. If any damage

More information

Welding Safety Catalogue

Welding Safety Catalogue WELDING SAFETY CATALOGUE 2018 Welding Safety Catalogue 1 Need it? We got it! You re needing a solution to protect your welders and engineers against welding hazards and fumes? Wanting greater clarity and

More information

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL AL- Model Number Date Code / Serial Number Date of Purchase LIMITED WARRANTY ALITA warrants to the original retail consumer purchaser ( Customer ) that

More information

5-13 AUTO DARKENING WELDING HELMET INSTRUCTIONS FOR USE. Variable Shade

5-13 AUTO DARKENING WELDING HELMET INSTRUCTIONS FOR USE. Variable Shade 5-13 Variable Shade AUTO DARKENING WELDING HELMET Please ensure you read this instruction manual carefully before using your Welding Helmet INSTRUCTIONS FOR USE Staple your receipt here in order to aid

More information

LESTRONIC II BATTERY CHARGER BUILT-IN OR PORTABLE CHARGERS

LESTRONIC II BATTERY CHARGER BUILT-IN OR PORTABLE CHARGERS LESTRONIC II BATTERY CHARGER BUILT-IN OR PORTABLE CHARGERS PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING INSTRUCTIONS For correct operation of the equipment, it is important to read and be familiar

More information

Toll Free:

Toll Free: GenVX Series Airline Respirator The next generation of blasting. The GenVX is the newest blasting helmet from Bullard, providing users with the industry s lightest, coolest, most comfortable, and most

More information

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

24 VOLT AUTOMATIC BATTERY CHARGER PART NO 24 VOLT AUTOMATIC BATTERY CHARGER PART NO. 957732 AC Input: DC Output: Battery Type: Specifications 230 volts, 50 hertz, 3.5 amps, single-phase 24 volts, 20 amps initially tapering to 6 amps 24 volt, 12

More information

WARNING ATTENTION. Please read this information carefully before operating your safe.

WARNING ATTENTION. Please read this information carefully before operating your safe. WARNING Please use caution when unbolting this safe from its shipping skid. Sports Afield recommends anchoring your safe to the floor. Failure to do so may cause the safe to fall forward. ATTENTION Please

More information

Hydraulic Long Jacks

Hydraulic Long Jacks Operating Instructions & Parts Manual Hydraulic Long Jacks Model 44915 44930 44940 44980 44981C (Air option) Capacity 1-1/2 Ton 3 Ton 4 Ton 8 Ton 8 Ton Models 44915, 44930, 44940 & 44980 Model 44981C U.S.

More information

ESCORT LC Pump. Instruction Manual WARNING

ESCORT LC Pump. Instruction Manual WARNING ESCORT LC Pump Instruction Manual WARNING THIS MANUAL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR USING OR SERVICING THE PRODUCT. Like any piece of complex equipment,

More information

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference. User s Guide Oreck Air Purifier with HEPA Filtration Important! Read this manual carefully, and keep for future reference. Enjoy Congratulations on your purchase of the Oreck Air Purifier with HEPA Filtration.

More information

GARDEN HOSE UTILITY PUMP

GARDEN HOSE UTILITY PUMP GARDEN HOSE UTILITY PUMP MODEL #HPP360, HPP12V, 473707 MODEL #HPP360, 473707 MODEL #HPP12V ATTACH YOUR RECEIPT HERE Purchase Date SAFETY INFORMATION Please read and understand this entire manual before

More information

Air Actuated Hydraulic Bottle Jacks

Air Actuated Hydraulic Bottle Jacks Air Actuated Hydraulic Bottle Jacks Operating Instructions & Parts Manual Model Number Atd-7412 Atd-7420 Capacity 12 Ton 20 Ton Atd Tools Inc. 160 Enterprise Drive, Wentzville MO 63385 Printed in China

More information

Lumina 28 Traction Drive Model: Battery Burnisher M28036TDQP OPERATION SERVICE PARTS CARE

Lumina 28 Traction Drive Model: Battery Burnisher M28036TDQP OPERATION SERVICE PARTS CARE Lumina 28 Traction Drive Model: Battery Burnisher M28036TDQP OPERATION SERVICE PARTS CARE Table of Contents IMPORTANT SAFETY INSTRUCTIONS...1 OPERATING INSTRUCTIONS...2 INSPECTION...2 ELECTRICAL...2 BATTERIES...2

More information

ICE Pump User Manual. ICE Pump

ICE Pump User Manual.  ICE Pump ICE Pump User Manual ICE Pump GENERAL INFORMATION The Bullard ICE pump transfers ambient air from a clean air location, where breathable air can be assured at all times, to workers wearing Type C or CE

More information

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET LESTRONIC II BATTERY CHARGER TAYLOR-DUNN 79-301-10 MODEL 13110-32 TYPE 24LC25-8ET AC Supply: DC Output: Battery Capacity: Specifications 120 volts, 60 Hertz, single-phase 24 volts, 32 amps Use only on

More information

Warning Statement Read Before Riding

Warning Statement Read Before Riding Table of Contents Technical Information-----------------------------------1 Warning Statement--------------------------------------2 Read Before Riding------------------------------------- List Of Parts-----------------------------------------------4

More information

O W N E R ' S M A N U A L

O W N E R ' S M A N U A L 1500 Watt DC to AC Power Inverter C o n v e r t s 1 2 V D C B a t t e r y P o w e r t o 1 1 0 V A C H o m e P o w e r O W N E R ' S M A N U A L SAVE THESE INSTRUCTIONS The recommended source of power is

More information

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

18VDC ESB6 Series Cordless Screwdrivers Operation Manual 18VDC ESB6 Series Cordless Screwdrivers Screwdriver Models : ESB6-8, ESB6-12, ESB6-15, ESB6-22 CAUTION - Please read, understand, and follow all operating and safety instructions in this manual before

More information

QPET, QPETXU Battery Chargers

QPET, QPETXU Battery Chargers C O R P O R A T IO N O P E R A T I N G I N S T R U C T I O N S QPET, QPETXU Battery Chargers INTRODUCTION: The QPET line of chargers are designed for general purpose deep cycle batteries. They are an electronically

More information

Air Actuated Hydraulic Bottle Jack on Wheels

Air Actuated Hydraulic Bottle Jack on Wheels Operating Instructions & Parts Manual Air Actuated Hydraulic Bottle Jack on Wheels Model Number 18127 18207 Capacity 12 Ton 20 Ton Shinn Fu Co. of America, Inc. 2002 10939 N. Pomona Avenue Kansas City,

More information

Hydraulic Truck Jack

Hydraulic Truck Jack Operating Instructions & Parts Manual Hydraulic Truck Jack Model Capacity 23221C 22 Ton 23222C (Low Profile) 22 Ton 23301 30 Ton Models 23221C & 23222C Model 23301! U.S. Patent No's. 5,341,723 & 5,94,912

More information

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP Model 54011-0 OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP Questions, problems, missing parts? Before returning to the store call AQUAPRO Customer Service 8 a.m. - 5 p.m., EST, Monday-Friday 1-844-242-2475

More information

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD ----------------------------------------------------------------We Make Clean Air----------------------------------------------------------------

More information

Replay Fabric Replacement Top

Replay Fabric Replacement Top Replay Fabric Replacement Top Installation Instructions For: GEO Tracker, Suzuki Sidekick Part Number: 51137 & Vitara 1986-1994 WARNING This product is designed to enhance the appearance of the vehicle

More information

18VDC ESB6-X Series Cordless Screwdrivers Operation Manual

18VDC ESB6-X Series Cordless Screwdrivers Operation Manual 18VDC ESB6-X Series Cordless Screwdrivers Screwdriver Models : ESB6-X3.5, ESB6-X3.5F, ESB6-X5F ESB6-X6, ESB6-X9, ESB6-X12 CAUTION - Please read, understand, and follow all operating and safety instructions

More information

AeraMax Pro AM IV. Please read these instructions before use. Do not discard: keep for future reference.

AeraMax Pro AM IV. Please read these instructions before use. Do not discard: keep for future reference. AeraMax Pro AM IV Please read these instructions before use. Do not discard: keep for future reference. ENGLISH AeraMax PRO Air Quality Control System: AM IV SAFETY INSTRUCTIONS/WARNING Thank you for purchasing

More information

TACTICAL BALLISTIC HELMET II (TBH II )

TACTICAL BALLISTIC HELMET II (TBH II ) CARE AND USE INSTRUCTIONS TACTICAL BALLISTIC HELMET II (TBH II ) Standard and Special Operation Configurations 2010 Gentex Corporation When you replace components or install additional components on Gentex

More information

Operator s Safety and Service Manual

Operator s Safety and Service Manual !! Operator s Safety and Service Manual Cordless Sprayer Model: C100WO SMK Industries Inc 12839 Carpenter Trail Carlisle. IA 50047 Phone: 515-202-0052 Email: john@smksprayers.com Web: www.smksprayers.com

More information

Installation Instructions

Installation Instructions Installation Instructions Rock Crawler Roof Rack (Part # 76717) 07-Up Jeep Wrangler J/K 4Door For Technical Support/Warranty Information please call 310-762-9944 Smittybilt, 400 West Artesia Blvd, Compton,

More information

PRODUCT NUMBER: A EUROMASKI VL

PRODUCT NUMBER: A EUROMASKI VL Europe / Africa PRODUCT NUMBER: A114703 EUROMASKI VL EUROMASKI VL is part of the Honeywell welding helmet range designed for use with powered air purifying respirator (PAPR) as Compact Air 200 and Compact

More information

MODEL FA5 Air Filtration System. Operations Manual

MODEL FA5 Air Filtration System. Operations Manual MODEL FA5 Air Filtration System Operations Manual READ AND SAVE THESE INSTRUCTIONS WARNING: Disconnect from power supply before performing maintenance procedures such as cabinet cleaning, changing filters

More information

M-3025CB-AV Fuel Pump

M-3025CB-AV Fuel Pump SAVE THESE INSTRUCTIONS M-3025CB-AV Fuel Pump Owner s Manual TABLE OF CONTENTS General Information... 2 Safety Instructions... 2 Installation... 3 Operation... 4 Maintenance... 4 Repair... 5 Troubleshooting...

More information

A/C PRESSURE MONITOR INSTALLATION INSTRUCTIONS SYSTEM OPERATION GREEN INDICATOR LIGHT

A/C PRESSURE MONITOR INSTALLATION INSTRUCTIONS SYSTEM OPERATION GREEN INDICATOR LIGHT A/C PRESSURE MONITOR INSTALLATION INSTRUCTIONS Do not attempt to clean or inspect anything while the engine is running. Cleaning and inspection must be done by a certified mechanic. All A/C service must

More information

INSTRUCTION MANUAL PROTECTING YOU FOR LIFE S BEST MOMENTS

INSTRUCTION MANUAL PROTECTING YOU FOR LIFE S BEST MOMENTS INSTRUCTION MANUAL Employers: Read this manual and carry out the Employer Responsibilities (page 5). Product users: Read this manual and follow the Product User Safety Instructions (page 6). Make sure

More information

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup. Instructions/Parts MGFHVLP Mini Gravity Feed System FOR PRODUCT INFORMATION CALL: 1-800-742-7731 309989E For gravity feed spraying of automotive colors and clears. Ideal for touch-up and detail work. Important

More information

FlexChem Model 404 Rotating Oven

FlexChem Model 404 Rotating Oven www.scigene.com FlexChem Model 404 Rotating Oven USER MANUAL Cat. #1052-20-1, 1052-20-2, 1052-22-1 & 1052-22-2 FOR RESEARCH USE ONLY Not for Use in Diagnostic Procedures SciGene 306 Potrero Ave, Sunnyvale,

More information

OBE, OBEXU, ON BOARD Battery Chargers

OBE, OBEXU, ON BOARD Battery Chargers C O R P O R A T IO N O P E R A T I N G I N S T R U C T I O N S OBE, OBEXU, ON BOARD Battery Chargers INTRODUCTION: These chargers are designed for the permanent installation on battery powered vehicles

More information

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI 15 GALLON AIR COMPRESSOR Model: 7678 DO NOT RETURN TO STORE Please call 800-348-5004 for parts and service CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials

More information

VANGUARD A EZ INSTALL OPERATOR S MANUAL

VANGUARD A EZ INSTALL OPERATOR S MANUAL Parker Hannifin Corporation Porter Instrument Division 245 Township Line Rd. P.O. Box 907 Hatfield, PA 19440-0907 USA (215) 723-4000 / fax (215) 723-5106 VANGUARD A EZ INSTALL OPERATOR S MANUAL FM-1145

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS Table of Contents Safety... 2 Specifications... 3 Functions... 4 Operation... 5 Maintenance... 7 Warranty... 7 SAFETY SPECIFICATIONS OPERATION MAINTENANCE WARNING SYMBOLS AND DEFINITIONS This is the safety

More information

Model 700 Microarray Oven

Model 700 Microarray Oven www.scigene.com Model 700 Microarray Oven USER MANUAL Cat. #1070-00-1, 1070-00-2 FOR RESEARCH USE ONLY Not for Use in Diagnostic Procedures SciGene 306 Potrero Ave, Sunnyvale, CA 94085 USA 408-733-7337

More information

Cordless Sweeper. OWNER S MANUAL Model: CFT Volt DC. Made Exclusively for ALDI Inc. Batavia, IL.,

Cordless Sweeper. OWNER S MANUAL Model: CFT Volt DC. Made Exclusively for ALDI Inc. Batavia, IL., Cordless Sweeper OWNER S MANUAL Model: CFT25 4.8 Volt DC Made Exclusively for ALDI Inc. Batavia, IL., 60510-1477 CFT25 ONE (1) YEAR LIMITED WARRANTY This product is warranted to be free from defects in

More information

60 Watt Industrial LED Low Bay Light

60 Watt Industrial LED Low Bay Light 60 Watt Industrial LED Low Bay Light Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety

More information

Installation Instructions Seat Cover, Rear Kit WARNING. Support. We re here to help! Go to and click Contact Us.

Installation Instructions Seat Cover, Rear Kit WARNING. Support. We re here to help! Go to   and click Contact Us. Installation Instructions Seat Cover, Rear Kit Vehicle Application: Wrangler Unlimited 008-0 Part Number 98 Installation Tips Read and follow, precisely, all installation instructions provided when installing

More information

Podiatry Procedures Chair. For Models: Barrier-Free. User s Guide

Podiatry Procedures Chair. For Models: Barrier-Free. User s Guide Podiatry Procedures Chair For Models: 646 647 Barrier-Free User s Guide Product Information (The information below is required when calling for service.) Dealer : Date of Purchase: Model / Serial Number:

More information

DURAFLOW POWERED AIR RESPIRATOR

DURAFLOW POWERED AIR RESPIRATOR DURAFLOW POWERED AIR RESPIRATOR DURABLE PROTECTION DURAFLOW Scott Safety s new DURAFLOW PAPR provides durable, versatile protection for users in a wide range of demanding environments at an affordable

More information

RANGE HOODS USER INSTRUCTIONS

RANGE HOODS USER INSTRUCTIONS RANGE HOODS USER INSTRUCTIONS Model: Advanta Pro III 30 & 36 IMPORTANT SAFETY INSTRUCTIONS Carefully read the following important information regarding installation safety and maintenance. Keep these instructions

More information

182-LED Solar-Powered Motion Security Light. Owner s Manual

182-LED Solar-Powered Motion Security Light. Owner s Manual 182-LED Solar-Powered Motion Security Light Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other

More information

T1-Titanium Non-HVLP Spray Gun

T1-Titanium Non-HVLP Spray Gun T1-Titanium Non-HVLP Spray Gun THE SPRAY GUN PEOPLE FOR PRODUCT INFORMATION CALL: 1-800-742-7731 Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions.

More information

AQUA2000 ADVANCED WATER TREATMENT SYSTEMS OWNER S MANUAL INCLUDES: Restrictions. Installation. Operation. Maintenance. Changing the Filter

AQUA2000 ADVANCED WATER TREATMENT SYSTEMS OWNER S MANUAL INCLUDES: Restrictions. Installation. Operation. Maintenance. Changing the Filter The world leader in products for a healthy and comfortable environment - bringing the Garden of Eden into your home. AQUA2000 OWNER S MANUAL INCLUDES: Restrictions Installation Operation Maintenance Changing

More information

Replace - A - Top Installation Instructions

Replace - A - Top Installation Instructions Replace - A - Top Installation Instructions For: Suzuki Samurai Part Number: 51361 Congratulations on your purchasing decision. Bestop designed this Convertible Top to give you years of dependability and

More information

Air-Operated Waste Oil Drainer

Air-Operated Waste Oil Drainer Air-Operated Waste Oil Drainer 20-Gallon Tank Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other

More information

Spotlight 1,000,000 Power Series Cordless Rechargeable

Spotlight 1,000,000 Power Series Cordless Rechargeable VEC156CFL_Manual_012405 1/24/05 4:29 PM Page iv VEC156 Spotlight 1,000,000 Power Series Cordless Rechargeable OWNER S MANUAL & WARRANTY INFORMATION 53SB E231887 IMPORTANT SAFETY INFORMATION, SAVE THESE

More information

Scale Feeder Manifold Water Filtration System Instruction Manual

Scale Feeder Manifold Water Filtration System Instruction Manual 3M TM Water Filtration Products Scale Feeder Manifold Water Filtration System Instruction Manual For SF1XX High Flow Series Water Filtration Systems Installer: Please leave this manual with owner/operator.

More information

Specialty Pond Sprayer

Specialty Pond Sprayer Specialty Pond Sprayer 2.75 Gallon Capacity Sprayer Installation & Maintenance Manual (Item # 580121) 1 Year Warranty Specialty Pond Sprayer 2.75 Gallon Capacity Sprayer Thank you for purchasing this compression

More information

MODUL-CONNECT 1.2. Owner s Manual. Modular, digital wiring and control system. Document Part Number MSMC Rev 9 (04/18)

MODUL-CONNECT 1.2. Owner s Manual. Modular, digital wiring and control system. Document Part Number MSMC Rev 9 (04/18) MODUL-CONNECT 1.2 Modular, digital wiring and control system Owner s Manual Document Part Number MSMC Rev 9 (04/18) Service Contact Information E-mail: info@modul-system.com Phone: +46 31 746 87 00 Web:

More information

ATD Amp Carbon Pile Battery Tester User s Manual WARNING

ATD Amp Carbon Pile Battery Tester User s Manual WARNING ATD-5489 500 Amp Carbon Pile Battery Tester User s Manual WARNING Failur e to follow instructions may cause damage or explosion, always shield eyes. Read entire instruction manual before use. Warning:

More information

ARM-EVAC 50. Benchtop Plenum/Arm Extractor MANUAL NO REV. B

ARM-EVAC 50. Benchtop Plenum/Arm Extractor MANUAL NO REV. B ARM-EVAC 50 Benchtop Plenum/Arm Extractor MANUAL NO. 8881-0980 REV. B TABLE OF CONTENTS Safety. 3 Introduction 4 Specification.. 4 Features. 5 Set-Up. 6 Operation 7 Maintenance.. 7 Troubleshooting.. 8

More information

IMPORTANT SAFETY INFORMATION

IMPORTANT SAFETY INFORMATION Specifications Overall Dimensions Batteries 9" L x 6-3/4" W x 6-3/4" H 4 - AA (sold separately) IMPORTANT SAFETY INFORMATION Installation Precautions 1. Verify that installation surface has no hidden utility

More information

RF6 / RF10 / RF18 Installation Instructions

RF6 / RF10 / RF18 Installation Instructions RF6 / RF10 / RF18 Installation Instructions Thank you very much for purchasing PIAA product. Read this instruction manual thoroughly for proper use of the product. After completing your installation, please

More information

Operator s Safety and Service Manual

Operator s Safety and Service Manual Operator s Safety and Service Manual Cordless Sprayer Model: H100AC ALL CHEMICALS SMK Industries, Inc. 12839 Carpenter Trail Carlisle, IA 50047 Phone: 515-202-0052 Copyright 2014, SMK Industries Inc Email:john@smksprayers.comWeb:

More information

QSSE, QSSEX INDUSTRIAL Battery Chargers

QSSE, QSSEX INDUSTRIAL Battery Chargers C O R P O R A T IO N O P E R A T I N G I N S T R U C T I O N S QSSE, QSSEX INDUSTRIAL Battery Chargers INTRODUCTION The QSE line are electronically controlled float chargers. The batteries are brought

More information