1 Noise Impact Assessment Deer Creek Energy Limited Joslyn North Mine Prepared For Millennium EMS Solutions Prepared By Mr. James Farquharson, CET Mr. Clifford Faszer, P. Eng. Faszer Farquharson & Associates Ltd. December 30, 2005 FFA File

2 Executive Summary Deer Creek Energy Limited (DCEL) is submitting an application to the Energy and Utilities Board (EUB) and Alberta Environment (AENV) for approval to construct, operate, and reclaim the proposed Joslyn North Mine Project (the JNM Project). The JNM Project is located on the Joslyn Lease that consists of Oil Sands Leases (OSLs) T24 (OSL 24), (OSL 452, formerly Permit 70) and (OSL 799), which is approximately 70 kilometres north of Fort McMurray located in Townships 95 and 96, Ranges 11 and 12, W4M. For the purpose of this application the three leases will be referred to as Lease 24. As part of their application to the EUB DCEL is required to complete a Noise Impact Assessment. The results of this assessment are compared with the Permissible Sound Levels (PSL) of the EUB Noise Control Directive ID 99-8 (Directive) to determine compliance. The environmental noise propagation model prepared for this assessment may also be used to develop and evaluate noise control measures should the results indicate non-compliance. Millennium EMS Solutions, on behalf of DCEL, retained Faszer Farquharson & Associates to complete this assessment. This assessment follows previous assessments of the DCEL SAGD facilities located in Lease 24 by Faszer Farquharson & Associates. Faszer Farquharson & Associates used a combination of manufacturer s data, file data of previously measured mining equipment and theoretical assessment techniques to determine sound pressure levels of the significant noise sources associated with the proposed project. The sound pressure levels were used to calculate sound power levels for the significant noise sources associated with the proposed project equipment. Where appropriate, duty factors were assigned to the mining equipment based on information received from DCEL. Data regarding the topography and vegetation of the study area, along with the location of the trapper s cabin and the community of Fort McKay was provided by DCEL with supplemental information obtained from commercial sources. Significant noise sources associated with the DCEL SAGD facilities were also included. This information was used as input parameters for an environmental noise propagation computer model to calculate the sound level of the facility and mining operations at each point of interest. The modelling was completed for the mining operations located nearest the residences of interest. The modelling was undertaken for the years 2010, 2014, 2019 and This approach reflects dates of significant changes in mining operations and the positioning of the mining equipment in relation to the reception locations over the study period. i

3 The overall results of the modelling are presented in the following table in comparison to the allowable sound level limits. Predicted Sound Levels Deer Creek Joslyn North Mine Year Predicted Sound Level (dba) EUB Daytime Permissible Sound Level (dba L eq ) EUB Nighttime Permissible Sound Level (dba L eq ) Trappers Cabin Fort McKay FFA File The noise propagation model results indicate that the proposed mining operations for the development of the Joslyn North Mine would potentially comply with the daytime PSLs of the EUB Directive at both reception locations. The noise propagation model results further indicate that the nighttime sound level limits would be met up to 2014 at the trapper s cabin and through to year 2034 at Fort McKay. It is predicted that the nighttime sound level limits would be exceeded after the year 2014 at a trapper s cabin located on the DCEL Lease 24. Faszer Farquharson & Associates recommends that DCEL consider relocation of this cabin as a potential mitigation strategy to ensure that the project complies with the allowable sound level limits. Validating the noise model with on site measurement and monitoring program is also recommended. ii

4 Contents Executive Summary... i Background & Scope... 1 Site Description & Residence Locations... 1 Mining Equipment... 2 Approach... 2 Criteria... 3 Sound Power Level Calculations... 4 Noise Model... 5 Results... 6 Recommendations Cumulative Effects Conclusion Appendix A Permissible Sound Level Determination Trapper s Cabin...A-1 Fort McKay...A-2 iii

5 Tables Predicted Sound Levels ii Table 1 Mining Equipment 2 Table 2 Permissible Sound Levels 3 Table 3 Source Sound Power Levels 4 Table 4 Modeled Conditions 5 Table 5 Predicted Sound Levels 6 Table 6 Order Ranked Sound Pressure Levels 7 Trapper s Cabin Year 2019 Table 7 Order Ranked Sound Pressure Levels 8 Fort McKay Year 2019 Table 8 Order Ranked Sound Pressure Levels 9 Trapper s Cabin Year 2034 Table 9 Order Ranked Sound Pressure Levels 10 Fort McKay Year 2034 iv

6 List of Figures Figure 1 - Regional Area Map Figure 2 - Lease 24 Map with contours and receptor locations Figure 3 - Mine Development 2010 and 2014 Figure 4 - Mine Development 2019 and 2034

7 Background & Scope Deer Creek Energy Limited (DCEL) is submitting an application to the Energy and Utilities Board (EUB) and Alberta Environment (AENV) for approval to construct, operate, and reclaim the proposed Joslyn North Mine Project (the JNM Project). The JNM Project is located on the Joslyn Lease that consists of Oil Sands Leases (OSLs) T24 (OSL 24), (OSL 452, formerly Permit 70) and (OSL 799), which is approximately 70 kilometres north of Fort McMurray located in Townships 95 and 96, Ranges 11 and 12, W4M (Figure 1). For the purpose of this application the three leases will be referred to as Lease 24. As part of their application to the EUB DCEL is required to complete a Noise Impact Assessment. The results of this assessment are compared with the Permissible Sound Levels (PSL) of the EUB Noise Control Directive ID 99-8 (Directive) to determine compliance. The environmental noise propagation model prepared for this assessment may also be used to develop and evaluate noise control measures should the results indicate non-compliance. Millennium EMS Solutions, on behalf of DCEL, retained Faszer Farquharson & Associates to complete this assessment. This assessment follows previous assessments of the DCEL SAGD facilities located in Lease 24 by Faszer Farquharson & Associates. Site Description & Residence Locations The DCEL Joslyn North Mine is located within oil sands Lease 24. The processing facility will be located near the northern boundary of Lease 24 in SEC W4M, approximately 15 kilometres northwest of Fort McKay, Alberta. The nearest dwelling to the mine and plant site identified by DCEL is a trapper s cabin located on the south side of the Ells River in LSD W4M. This cabin is approximately 7 kilometres from the proposed DCEL plant site and approximately 2 kilometres south of the main external disposal area. In addition to the location of the area residences, bordering the north boundary of DCEL Lease 24 is the Canadian Natural Resources Limited (CNRL) Lease 18 Horizon Project. This project presently under development includes a bitumen mine and processing facility. Figure 2 presents a contour map of the study area indicating the DCEL Joslyn North Mine, the reception locations for which modelling was completed and other area features. 1

8 Mining Equipment Table 1 lists the major equipment proposed for use in the Joslyn North Mine. The equipment is anticipated to operate on a 24 hour per day basis. Table 1 Mining Equipment Deer Creek Joslyn North Mine Equipment Description Approach Terex MT 5500 Truck P & H 4100 Shovel Caterpillar 992 Loader Caterpillar 24 Grader Caterpillar 844 RT Dozer Caterpillar 16 Grader Caterpillar 793 Water Truck Caterpillar D11 Dozer Caterpillar 385B Backhoe Caterpillar 988 Loader Caterpillar D10 Dozer Caterpillar 777 Haul Truck Caterpillar 330B Backhoe Caterpillar D7 Side Track Dozer Caterpillar 583R Side Boom Track Dozer FFA File Faszer Farquharson & Associates used a combination of manufacturer s data, file data of previously measured mining equipment and theoretical assessment techniques to determine sound pressure levels of the significant noise sources associated with the proposed project. The sound pressure levels were used to calculate sound power levels for the significant noise sources associated with the proposed project equipment. Where appropriate duty factors were assigned to the mining equipment based on information received from DCEL. Data regarding the topography and vegetation of the study area, along with the location of the trapper s cabin and the community of Fort McKay was provided by DCEL with supplemental information obtained from commercial sources. Significant noise sources associated with the DCEL SAGD facilities were also included. This information was used as input parameters for an environmental noise propagation computer model to calculate the sound level of the facility and mining operations at each point of interest. The modelling was completed for the mining operations located nearest the residences of interest. The modelling was undertaken for the years 2010 and 2014 (shown in Figure 3), 2019 and 2034 (shown in Figure 4). This approach reflects dates of significant changes in mining operations and the positioning of the mining equipment in relation to the reception locations over the study period. The results of the modelling were reviewed and compared to the PSLs of the EUB Directive to determine the potential for compliance at each reception location. The model may also be used to develop and evaluate noise control measures if the results exceed the allowable levels of the EUB Directive. The expected change in sound level resulting from the noise control measures can then be predicted to the points of interest. 2

9 Criteria The EUB Directive is a receiver-oriented noise regulation that applies to energy industry facilities operating in the Province of Alberta under EUB license. The Directive requires a Noise Impact Assessment for any permanent facility where there is a reasonable expectation of a continuous noise source. This Directive specifies allowable sound levels for energy industry facilities at designated receptor points including residences. In lieu of a residence within 1500 metres of a facility, the Directive indicates that a level of 40 dba L eq should not be exceeded at this distance during the nighttime. These specified limits are the permissible sound levels (PSLs). The Directive requires that all facilities licensed after October 1988 meet the PSLs of the Directive. Actual compliance can only be determined by comparing the comprehensive sound level to the permissible sound levels of a valid comprehensive sound survey. Although it is not mandatory that a comprehensive sound survey be completed, the EUB expects that the comprehensive sound level of the facility comply with the applicable PSLs. The PSLs are derived from information regarding the area population density; proximity to heavily travelled transportation routes including motor vehicle routes, rail lines, aircraft flyways and other specified adjustments. The PSL during the daytime may be adjusted to a level 10 dba above the nighttime level. Table 2 presents the PSLs for the locations assessed. The detailed determination of the PSLs is presented in Appendix A. Table 2 Permissible Sound Levels Deer Creek Joslyn North Mine Location Daytime Permissible Sound Level (dba L eq ) Nighttime Permissible Sound Level (dba L eq ) Community of Fort McKay Trapper s Cabin FFA File

10 Sound Power Level Calculations Sound power levels of the plant and mining equipment were calculated from a combination of manufacturer s data, file data of previously measured mining equipment and theoretical assessment techniques. The calculations followed accepted acoustical engineering evaluation methods for the determination of sound power levels from sound pressure levels for large machinery. Table 3 presents the calculated sound power levels of the significant project noise sources. The values are order ranked from highest to lowest overall dba sound power level. Table 3 Source Sound Power Levels Deer Creek Joslyn North Mine Description Sound Power Level (db re: W) Octave Band Centre Frequency (Hz) Sum (dba) Plant Terex MT 5500 Truck (dumping) Crusher P & H 4100 Shovel Caterpillar 992 Loader Caterpillar 24 Grader Terex MT 5500 Truck (box down) Caterpillar 844 RT Dozer Caterpillar 16 Grader Caterpillar 793 Water Truck Caterpillar D11 Dozer Caterpillar 385B Backhoe Caterpillar 988 Loader Caterpillar D10 Dozer Caterpillar 777 Haul Truck Caterpillar 330B Backhoe Caterpillar D7 Side Track Dozer Caterpillar 583R Side Boom Track Dozer FFA File The order ranked sound pressure levels at a distant point of reception may differ from the source order ranked sound power levels. This can occur for a number of reasons including duration of operation, the frequency composition of each noise source, the physical height of the noise source above the ground, acoustical shielding at the site or the topography between the site and the receiver. 4

11 Noise Model Faszer Farquharson & Associates employed the use of ENM, an environmental noise propagation model, for this assessment. ENM is an environmental noise assessment software package from RTA Technology Pty. Ltd. The calculated source sound power levels complete with the physical information regarding the mining equipment layout and location of the residences were entered in the model. The meteorological conditions selected favoured the transmission of sound from the mining equipment to each point of reception and thus emulate a period during which DCEL may experience noise complaints regarding their operations. Table 4 lists the selected conditions. Table 4 Modeled Conditions Deer Creek Joslyn North Mine Parameter Modeled Input +25 C 5.0 kph Temperature Wind Velocity Wind Direction Relative Humidity 50% Topography Yes Terrain Category Rural Ground Type Grass Temperature Gradient ( C/100m) 0 Receiver height above ground 1.5m From the mine to each residence FFA file Faszer Farquharson & Associates reviewed model input and results during the modelling process and, where warranted, additional calculations were completed outside of the model to verify the ENM results. Given the terrain is a mixture of forest, muskeg, cleared lands and mined lands Faszer Farquharson & Associates selected grass as the ground type. 5

12 Results Table 5 presents the overall modeled sound pressure levels the Joslyn North Mine to each selected reception point for the four individual years that were evaluated. The modelling was completed using a receiver elevation of 1.5 metres above the ground surface at each point of reception. Table 5 Predicted Sound Levels Deer Creek Joslyn North Mine Year Discussion of Results Predicted Sound Level (dba) EUB Daytime Permissible Sound Level (dba L eq ) EUB Nighttime Permissible Sound Level (dba L eq ) Trappers Cabin * * ** ** Fort McKay * * ** ** FFA File *Shown on Figure 3 **Shown on Figure 4 The results indicate that the allowable daytime sound level limit would be met at both receiver locations. The results also indicate that the nighttime allowable sound level limit is met up to 2014 at the trapper s cabin and through to year 2034 at Fort McKay. Sometime between years 2014 and 2019 the sound level of the project is predicted to exceed the allowable nighttime sound level at the trapper s cabin through to the end of the project. 6

13 Table 6 presents the source order-ranked results for the top 30 noise sources at the trapper s cabin in year The detailed results are order ranked by noise source and thus highlight the significance of the noise from the various pieces of mining equipment and the plant. Table 6 Trapper s Cabin Year 2019 Order Ranked Sound Pressure Levels Deer Creek Joslyn North Mine Source Source Sound Level Contribution (dba) Terex MT 5500 Truck Dumping Top of Pile 36.1 Terex MT 5500 Truck Dumping Reclaim 35.4 Deer Creek Plant 35.0 Terex RH200 Middle Bench 33.8 Terex RH200 High Bench 30.1 Caterpillar D11Dozer Top of Pile 26.5 Caterpillar D11Dozer Reclaim 25.3 P & H 4100 Shovel Bench Caterpillar 385B Backhoe Top of Pile 22.9 P & H 4100 Shovel Bench P & H 4100 Shovel Pit Caterpillar 992 Loader Higher Bench 20.0 Caterpillar 24 Grader On Bench 19.7 Caterpillar 844 RT Dozer Medium Bench 19.3 Caterpillar D11Dozer Top Bench 19.1 Caterpillar D11Dozer Middle Bench 18.9 Caterpillar 385B Backhoe Bench 17.0 Terex MT 5500 Truck Hauling Top of Reclaim 16.5 Caterpillar 385B Backhoe Pit 15.1 Caterpillar 988 Loader Mid Bench 15.0 Terex MT 5500 Truck Higher Bench 14.8 Caterpillar D10 Dozer Lower Bench 14.5 Caterpillar 24 Grader On Haul Road 14.5 Terex MT 5500 Truck Hauling Top of Pile 14.1 Caterpillar 24 Grader By Plant 13.7 Crusher 13.6 Caterpillar 24 Grader Road Toward Crusher 12.9 Phase IIIA Cooler Inlet 11.8 Phase II Cooler Inlet 11.2 Caterpillar 793 Water Truck Pit 9.6 Project Sum 42.2 FFA File Note: Sound Pressure level values below the reference level of 20 micro Pascals are indicated by a negative sign preceding the value. The results indicate that the central plant and the trucks dumping are the two most significant noise sources at trappers cabin in

14 Table 7 presents the source order-ranked results for the top 30 noise sources at Fort McKay in year The detailed results are order ranked by noise source and thus highlight the significance of the noise from the various pieces of mining equipment and the plant. Table 7 Fort McKay Year 2019 Order Ranked Sound Pressure Levels Deer Creek Joslyn North Mine Source Source Sound Level Contribution (dba) Terex RH200 High Bench 18.6 Deer Creek Plant 18.4 Terex MT 5500 Truck Dumping Top of Pile 14.6 Terex MT 5500 Truck Dumping Reclaim 14.3 P & H 4100 Shovel Pit Caterpillar D11Dozer Top of Pile 7.0 Caterpillar D11Dozer Reclaim 5.6 Caterpillar 24 Grader Road Toward Crusher 4.9 Caterpillar 385B Backhoe Top of Pile 4.9 Terex RH200 Middle Bench 4.8 Phase IIIA Cooler Inlet -0.6 Phase II Cooler Inlet -4.5 Caterpillar D11Dozer Top Bench -4.9 Terex MT 5500 Truck Hauling Top of Pile -5.0 Caterpillar 992 Loader Bench -5.0 P & H 4100 Shovel Pit Phase IIIA Cooler Outlet -5.6 Caterpillar 24 Grader On Haul Road -6.4 Terex MT 5500 Truck Hauling Top of Reclaim -6.6 Caterpillar 385B Backhoe Pit -6.9 P & H 4100 Shovel Bench P & H 4100 Shovel Bench Caterpillar 24 Grader By Plant -7.3 Caterpillar 385B Backhoe Bench -8.1 Caterpillar 24 Grader On Bench -8.3 Caterpillar 992 Loader Higher Bench -8.5 Crusher -8.7 Phase II Cooler Outlet -9.4 Phase III Heater Outlet -9.9 Caterpillar 844 RT Dozer Pit Project Sum 23.6 FFA File Note: Sound Pressure level values below the reference level of 20 micro Pascals are indicated by a negative sign preceding the value. The results indicate that the central plant and the trucks dumping are the two most significant noise sources at Fort McKay in

15 Table 8 presents the source order-ranked results for the top 30 noise sources at the trapper s cabin in year The detailed results are order ranked by noise source and thus highlight the significance of the noise from the various pieces of mining equipment and the plant. Table 8 Trapper s Cabin Year 2034 Order Ranked Sound Pressure Levels Deer Creek Joslyn North Mine Source Source Sound Level Contribution (dba) Terex MT 5500 Truck Dumping Pile 41.3 Deer Creek Plant 35.0 Terex RH200 Bench Terex RH200 Bench Terex RH200 Bench Terex MT 5500 Truck Dumping Reclaim 29.9 Caterpillar D11Dozer Top of Pile 29.4 Terex RH200 Bench Caterpillar D11Dozer Reclaim 21.0 Caterpillar 992 Loader Higher Bench 19.1 Caterpillar 992 Loader Bench 18.7 P & H 4100 Shovel Pit Caterpillar 793 Water Truck Pit 18.7 P & H 4100 Shovel Bench Caterpillar 385B Backhoe Top of Reclaim 17.8 P & H 4100 Shovel Pit Caterpillar D10 Dozer Reclaim 16.7 Terex RH200 Pit 15.7 Caterpillar 24 Grader On Haul Road 14.4 Terex MT 5500 Truck Haul Road Caterpillar 24 Grader By Plant 13.5 Crusher 13.1 Phase IIIA Cooler Inlet 12.7 Caterpillar D11Dozer Top Bench 12.4 Caterpillar 385B Backhoe Bench 12.1 Caterpillar 988 Loader Mid Bench 11.9 Caterpillar 844 RT Dozer Pit 11.5 Phase II Cooler Inlet 11.4 Terex MT 5500 Truck Hauling Top of Reclaim Terex MT 5500 Truck Dumping Crusher 9.6 Project Sum 44.0 FFA File Note: Sound Pressure level values below the reference level of 20 micro Pascals are indicated by a negative sign preceding the value. The results indicate that the central plant and the trucks dumping are still the two most significant noise sources at the trappers cabin in

16 Table 9 presents the source order-ranked results for the top 30 noise sources at the community of Fort McKay in year The detailed results are order ranked by noise source and thus highlight the significance of the noise from the various pieces of mining equipment and the plant. Table 9 Fort McKay Year 2034 Order Ranked Sound Pressure Levels Deer Creek Joslyn North Mine Source Source Sound Level Contribution (dba) Terex RH200 Bench Terex RH200 Bench Terex RH200 Bench Terex RH200 Bench Deer Creek Plant 18.4 Terex MT 5500 Truck Dumping Pile 17.1 Terex MT 5500 Truck Dumping Reclaim 13.6 Caterpillar 992 Loader Higher Bench 10.9 Caterpillar D11Dozer Top of Pile 8.4 Caterpillar 385B Backhoe Top of Reclaim 6.0 Caterpillar 385B Backhoe Bench 5.0 Caterpillar D11Dozer Reclaim 4.8 Caterpillar 988 Loader Mid Bench 3.4 Caterpillar D11Dozer Top Bench 3.2 Phase IIIA Cooler Inlet 2.4 Caterpillar D10 Dozer Reclaim 0.8 Caterpillar D10 Dozer Higher Bench -0.3 Terex MT 5500 Truck Hauling Top of Reclaim Terex MT 5500 Truck Higher Bench -1.6 Phase II Cooler Inlet -1.7 Terex RH200 Pit -2.1 Caterpillar 992 Loader Bench -2.1 Phase IIIA Cooler Outlet -2.5 P & H 4100 Shovel Bench Phase II Cooler Outlet -5.3 Caterpillar 793 Water Truck Pit -6.2 Caterpillar 24 Grader On Haul Road -6.7 Caterpillar 583R Side Boom Track Dozer -6.7 Caterpillar 24 Grader By Plant -7.5 Phase III Heater Outlet -8.1 Project Sum 31.7 FFA File Note: Sound Pressure level values below the reference level of 20 micro Pascals are indicated by a negative sign preceding the value. The results indicate that the central plant and the trucks dumping are the two most significant noise sources at Fort McKay in

17 Recommendations Faszer Farquharson recommends relocation of the trapper s cabin after year 2014 but before the year 2019 as a possible mitigation strategy when the project operations are predicted to exceed the allowable sound level limits. Faszer Farquharson & Associates recommends that DCEL initiate a community noise program as a component of the overall environmental program for the facility. The community noise program would record community noise concerns and address those concerns through sound level monitoring and mitigation programs as necessary. Cumulative Effects The EUB Directive requires that companies proposing facilities where there is already an energy industry presence need to consider the overall contribution of all energy industry facilities and ensure that the total energy industry sound level does not exceed the allowable levels. As CNRL is currently developing their Horizon Project, a bitumen mine, central extraction and upgrading facility that borders the northern edge of DCEL s Lease 24 a review is warranted. The Noise Assessment prepared for the CNRL Horizon project indicates that the sound of this project as proposed would spill onto DCEL s Lease 24. The CNRL assessment presents the results of four mining scenarios that are expected over the life of the project. Scenario 4 presents a situation where the sound of the CNRL activities would have the greatest impact on the DCEL Phase II, Phase IIIA SAGD and the Joslyn North Mine project areas. The noise impact of the CNRL Scenario 4 activities is predicted to have the greatest impact on the northern portions of the Deer Creek Lease 24 when CNRL mining activities are near the southern boundary of their lease. The CNRL assessment does not provide sufficient detailed information that could be combined with the Deer Creek noise model to determine the cumulative noise impact of the combined facilities. In a review of the available data it may be concluded that the Deer Creek operations would have the greatest impact on the receiver locations identified in this assessment and that the contribution of the CNRL operations would be significantly lower given the location of the receivers in respect to the CNRL facilities. Professional opinion suggests that the predicted noise impact of the Deer Creek facilities in combination with the CNLR facilities would not be measurably higher than that reported in this assessment. Faszer Farquharson & Associates has recommended additional assessment during the project life to determine if the operations exceed the EUB Noise Control Directive. That assessment would include the effect of the CNRL operations. Faszer Farquharson & Associates recommends a collective approach to community noise issues and encourages Deer Creek and CNRL to cooperate on such matters. This collective approach is favoured by the EUB in situations where more than one licensee may contribute to the noise environment at a receiver location. Conclusion The noise propagation model results indicate that the proposed mining operations for the development of the Joslyn North Mine would potentially comply with the daytime PSLs of the EUB Directive at all of the residences. The noise propagation model results 11

18 further indicate that the nighttime sound level limits would be exceeded after the year 2014 at a trapper s cabin located on the DCEL Lease 24. Faszer Farquharson & Associates recommends that DCEL consider relocation of this cabin as a possible mitigation strategy to ensure that the project complies with the allowable sound level limits. An on site noise measurement and monitoring program is also recommended to confirm the predicted noise levels. 12

19 Appendix A Permissible Sound Level Determination

20 Trapper s Cabin Permissible Sound Level Determination (PSL) Deer Creek Joslyn North Mine AEUB Noise Control Directive Basic Nighttime Sound Level (BSL) Nighttime Daytime (22:00-07:00) (07:00-22:00) Dwelling Unit Density per ¼ Section of Land Proximity to Transportation* 1 8 Dwellings Dwellings >160 Dwellings Category Category Category Class A Adjustments Class Reason for Adjustment Daytime Adjustment N/A 10 Basic Sound Level Value (dba L eq ) A1 Seasonal Adjustment (1 Nov 31 Mar) +5 A2 Absence of Both Tonal and Impulse/Impact Components +5 A3 Ambient Monitoring Adjustment -10 to +10 Class Adjustment = Sum of A1, A2 and A3 (as applicable), but not to exceed a maximum of 10 dba L eq Class B Adjustments Class Duration of Activity Total Class A Adjustments 0 0 Value (dba L eq ) B1 1 day +15 B2 1 week +10 B3 < or = to 2 months +5 B4 > 2 months Class B Adjustment = one only of B1, B2, B3 or B4 *Proximity to Transportation Category Definitions Class B Adjustment PERMISSIBLE SOUND LEVEL (dba) Category 1 Category 2 Category 3 Dwelling units more than 500m from heavily travelled roads and/or rail lines and not subject to frequent aircraft flyovers. Dwelling units more than 30m but less than 500m from heavily travelled roads and/or rail lines and not subject to frequent aircraft flyovers. Dwelling units less than 30m from heavily travelled roads and/or rail lines and subject to frequent aircraft flyovers. FFA File A-1

21 Fort McKay Permissible Sound Level Determination (PSL) Deer Creek Joslyn North Mine AEUB Noise Control Directive Basic Nighttime Sound Level (BSL) Nighttime Daytime (22:00-07:00) (07:00-22:00) Dwelling Unit Density per ¼ Section of Land Proximity to Transportation* 1 8 Dwellings Dwellings >160 Dwellings Category Category Category Class A Adjustments Class Reason for Adjustment Daytime Adjustment N/A 10 Basic Sound Level Value (dba L eq ) A1 Seasonal Adjustment (1 Nov 31 Mar) +5 A2 Absence of Both Tonal and Impulse/Impact Components +5 A3 Ambient Monitoring Adjustment -10 to +10 Class Adjustment = Sum of A1, A2 and A3 (as applicable), but not to exceed a maximum of 10 dba L eq Class B Adjustments Class Duration of Activity Total Class A Adjustments 0 0 Value (dba L eq ) B1 1 day +15 B2 1 week +10 B3 < or = to 2 months +5 B4 > 2 months Class B Adjustment = one only of B1, B2, B3 or B4 *Proximity to Transportation Category Definitions Class B Adjustment PERMISSIBLE SOUND LEVEL (dba) Category 1 Category 2 Category 3 Dwelling units more than 500m from heavily travelled roads and/or rail lines and not subject to frequent aircraft flyovers. Dwelling units more than 30m but less than 500m from heavily travelled roads and/or rail lines and not subject to frequent aircraft flyovers. Dwelling units less than 30m from heavily travelled roads and/or rail lines and subject to frequent aircraft flyovers. FFA File A-2

22

23 Main Menu Search Main TOC

24 Main Menu Search Main TOC

25 Main Menu Search Main TOC

Hydraulic excavator noise control case study as part of a comprehensive mitigation plan of an integrated open-pit coalmine and powerplant

Hydraulic excavator noise control case study as part of a comprehensive mitigation plan of an integrated open-pit coalmine and powerplant Hydraulic excavator noise control case study as part of a comprehensive mitigation plan of an integrated open-pit coalmine and powerplant Andrew C. Faszer a Rod MacDonald b Noise Solutions Inc. 301, 206

More information

Wal-Mart Canada Corp.

Wal-Mart Canada Corp. Decision 2010-596 New 500-kW Emergency Back-up Generator for Wal-Mart Perishable Foods Distribution Centre Balzac, Alberta December 17, 2010 ALBERTA UTILITIES COMMISSION Decision 2010-596: Wal-Mart Canada

More information

OIL SANDS ENGINEERING PROCEDURE 00-PRO-PC-0051 CNRL HORIZON ACCESS ROAD AND BRIDGE PROCEDURES

OIL SANDS ENGINEERING PROCEDURE 00-PRO-PC-0051 CNRL HORIZON ACCESS ROAD AND BRIDGE PROCEDURES OIL SANDS ENGINEERING PROCEDURE 00-PRO-PC-0051 CNRL HORIZON ACCESS ROAD AND BRIDGE PROCEDURES 0 13-Sep-05 Issued for Implementation GD DM PJ Rev # Date Revision Description By Checked Checked App d File

More information

APPENDIX D NOISE IMPACT ASSESSMENT

APPENDIX D NOISE IMPACT ASSESSMENT APPENDIX D NOISE IMPACT ASSESSMENT AURORA ACOUSTICAL CONSULTANTS Inc. 745 Warren Drive East Aurora, New York 14052 716-655-2200 info@auroraacoustical.com NOISE IMPACT ASSESSMENT OF NIGHTTIME PARKING LOT

More information

Decision (Errata) Access Pipeline Inc. Errata to Decision Temporary Generation at Smoky Lake Pump Station.

Decision (Errata) Access Pipeline Inc. Errata to Decision Temporary Generation at Smoky Lake Pump Station. Decision 2011-424 (Errata) Access Pipeline Inc. Errata to Decision 2011-424 Temporary Generation at Smoky Lake Pump Station January 4, 2012 The Alberta Utilities Commission Decision 2011-424 (Errata):

More information

Definitions of Acoustical Terms

Definitions of Acoustical Terms Appendix E Noise Definitions of Acoustical Terms Sound Measurements Decibel (db) A Weighted Decibel (dba) Maximum Sound Level (Lmax) Minimum Sound Level (Lmin) Equivalent Sound Level (Leq) Percentile

More information

DUFFERIN AGGREGATES ACTON QUARRY EXTENSION PROJECT

DUFFERIN AGGREGATES ACTON QUARRY EXTENSION PROJECT DUFFERIN AGGREGATES ACTON QUARRY EXTENSION PROJECT Noise Impact Study Project#: 06183 Prepared By: Steven Titus, B.A.Sc. P.Eng. Bob Rimrott, M.A.Sc, P.Eng AERCOUSTICS ENGINEERING LIMITED 50 Ronson Drive

More information

Alberta Electric System Operator Saleski Transmission Project Needs Identification Document

Alberta Electric System Operator Saleski Transmission Project Needs Identification Document Decision 2013-127 Alberta Electric System Operator Saleski Transmission Project Needs Identification Document ATCO Electric Ltd. Saleski 901S Substation and 144-kV Transmission Line 7L142 Facility Application

More information

PROPOSED HELICOPTER LANDING PAD 85 MILL ROAD LARA

PROPOSED HELICOPTER LANDING PAD 85 MILL ROAD LARA PROPOSED HELICOPTER LANDING PAD 85 MILL ROAD LARA Assessment of Helicopter Noise A report Prepared on behalf of: JamCo Constructions Pty Ltd PO Box 631 Yarraville Victoria 3013 Ref: 11573-3jg March 2015

More information

Bohn to Kettle River Transmission Project

Bohn to Kettle River Transmission Project April 2012 Why are you receiving this project information package? New transmission facilities are needed in the Fort McMurray area. ATCO Electric has been directed by the Alberta Electric System Operator

More information

Kettle River Transmission Project

Kettle River Transmission Project April 2012 Why are you receiving this project information package? New transmission facilities are needed in the Fort McMurray area. ATCO Electric has been directed by the Alberta Electric System Operator

More information

Update of noise database for prediction of noise on construction and open sites

Update of noise database for prediction of noise on construction and open sites Update of noise database for prediction of noise on construction and open sites Phase 3: Noise measurement data for construction plant used on quarries July 2006 www.defra.gov.uk Department for Environment,

More information

Alberta Energy and Utilities Board. Application to Construct and Operate Transmission Facilities

Alberta Energy and Utilities Board. Application to Construct and Operate Transmission Facilities Alberta Energy and Utilities Board Application to Construct and Operate Transmission Facilities Albian Sands Energy Inc. August 17, 2007 APPLICATION Shell Canada Limited (Shell), as operator, on behalf

More information

EMGA Mitchell McLennan Pty Limited (EMM) has been engaged to complete quarterly attended noise

EMGA Mitchell McLennan Pty Limited (EMM) has been engaged to complete quarterly attended noise 12 December 2014 Level 5, 21 Bolton Street Newcastle NSW 2300 PO Box 506 Leonard Sharp Environment and Community Liaison Officer Broken Hill Operations Pty Ltd CBH Resources Rasp Mine Newcastle, NSW, 2300

More information

November 29, 2017 BHEC-RES ALBERTA LP

November 29, 2017 BHEC-RES ALBERTA LP BHEC-RES ALBERTA LP Forty Mile Wind Power Project - Noise Impact Assessment Update Submitted to: Lucas Reindler Project Development Manager Renewable Energy Systems Canada Inc. as agent for BHEC-RES Alberta

More information

TRAFFIC IMPACT ASSESSMENT PART OF AN ENVIRONMENTAL IMPACT ASSESSMENT FOR THE KEBRAFIELD ROODEPOORT COLLIERY IN THE PULLEN S HOPE AREA

TRAFFIC IMPACT ASSESSMENT PART OF AN ENVIRONMENTAL IMPACT ASSESSMENT FOR THE KEBRAFIELD ROODEPOORT COLLIERY IN THE PULLEN S HOPE AREA TRAFFIC IMPACT ASSESSMENT PART OF AN ENVIRONMENTAL IMPACT ASSESSMENT FOR THE KEBRAFIELD ROODEPOORT COLLIERY IN THE PULLEN S HOPE AREA 20 March 2014 Report prepared by: Corli Havenga Transportation Engineers

More information

TRAFFIC IMPACT STUDY VICDOM BROCK ROAD PIT EXPANSION

TRAFFIC IMPACT STUDY VICDOM BROCK ROAD PIT EXPANSION TRAFFIC IMPACT STUDY VICDOM BROCK ROAD PIT EXPANSION TOWNSHIP OF UXBRIDGE P/N 05-1993 June 2011 Revised -August 2011 Prepared by: Skelton, Brumwell & Associates Inc. 93 Bell Farm Road, Suite 107 Barrie,

More information

Waste Licence Reg. No W Noise Compliance Annual Report: South Dublin County Council s (SDCC) Ballymount Baling Station

Waste Licence Reg. No W Noise Compliance Annual Report: South Dublin County Council s (SDCC) Ballymount Baling Station Noise and Vibration Consultants Ltd Reg No: IE 8298170M Principal: Brendan O Reilly MPhil (Noise & Vibration) ISEE SFA EAA Brendan O Reilly Phone: 046-9073497 Durhamstown Mobile:087-8199010 Bohermeen Email:

More information

TABLE OF CONTENTS FIGURES: MAP EXHIBITS: TABLES:

TABLE OF CONTENTS FIGURES: MAP EXHIBITS: TABLES: TransWest Express Transmission Project TABLE OF CONTENTS 7.0 DESIGN OPTIONS... 7-1 7.1 OVERVIEW OF DESIGN OPTIONS... 7-1 7.2 DESIGN OPTIONS PURPOSE AND NEED AND DESIGN CHARACTERISTICS... 7-4 7.2.1 Design

More information

COMMERCIAL SCHEME Approval No

COMMERCIAL SCHEME Approval No COMMERCIAL SCHEME Approval No. 12806 MADE at the City of Calgary, in the Province of Alberta, on ALBERTA ENERGY REGULATOR IN THE MATTER of a commercial scheme of Imperial Oil Resources Ventures Limited

More information

Kent Breeze Corporation. Noise Assessment Report. Kent Breeze Wind Farm and MacLeod Windmill Project H

Kent Breeze Corporation. Noise Assessment Report. Kent Breeze Wind Farm and MacLeod Windmill Project H Kent Breeze Corporation Kent Breeze Wind Farm and MacLeod Windmill Project H335112-0000-00-124-0001 0 May 14, 2010 Project Report Kent Breeze Corporation Kent Breeze Wind Farm and MacLeod Windmill Project

More information

Queenstown Generation Plant at LSD W4M

Queenstown Generation Plant at LSD W4M aci Acoustical Consultants Inc. 5031-210 Street Edmonton, Alberta, Canada T6M 0A8 Phone: (780) 414-6373 www.aciacoustical.com Noise Impact Assessment For The Queenstown Generation Plant at LSD 04-17-19-22-W4M

More information

FLAMBOROUGH QUARRY HAUL ROUTE STUDY HAUL ROUTE VIBRATION REPORT. itrans Consulting Inc 100 York Boulevard Richmond Hill, Ontario L4B 1J8

FLAMBOROUGH QUARRY HAUL ROUTE STUDY HAUL ROUTE VIBRATION REPORT. itrans Consulting Inc 100 York Boulevard Richmond Hill, Ontario L4B 1J8 FINAL REPORT FLAMBOROUGH QUARRY HAUL ROUTE STUDY HAUL ROUTE VIBRATION REPORT Project Number: #W08-5107A August 28, 2008 SUBMITTED TO: Tara Erwin itrans Consulting Inc 100 York Boulevard Richmond Hill,

More information

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE Copyright SFA - InterNoise 2000 1 inter.noise 2000 The 29th International Congress Exhibition on Noise Control Engineering 27-30 August 2000, Nice, FRANCE I-INCE Classification: 0.2 ITALIAN LEGISLATION

More information

Monitoring of Shoring Pile Movement using the ShapeAccel Array Field

Monitoring of Shoring Pile Movement using the ShapeAccel Array Field 2359 Royal Windsor Drive, Unit 25 Mississauga, Ontario L5J 4S9 t: 905-822-0090 f: 905-822-7911 monir.ca Monitoring of Shoring Pile Movement using the ShapeAccel Array Field Abstract: A ShapeAccel Array

More information

THE UNIVERSITY OF HONG KONG LIBRARIES. Hong Kong Collection

THE UNIVERSITY OF HONG KONG LIBRARIES. Hong Kong Collection THE UNIVERSITY OF HONG KONG LIBRARIES Hong Kong Collection TECHNICAL MEMORANDUM ON NOISE FROM PERCUSSIVE PILING Environmental Protection Department Noise Control Authority This Technical Memorandum, originally

More information

PORT DOVER WIND PROJECT

PORT DOVER WIND PROJECT PORT DOVER AND NANTICOKE WIND PROJECT NOISE ASSESSMENT REPORT Revision 3 For Zephyr North Ltd. 850 LEGION ROAD UNIT 20 BURLINGTON ON L7S 1T5 CANADA Phone: 905-335-9670 Fax: 905-335-0119 Internet: Info@ZephyrNorth.com

More information

ABERDEEN HARBOUR EXPANSION PROJECT November Volume 3: Technical Appendices ASSESSMENT

ABERDEEN HARBOUR EXPANSION PROJECT November Volume 3: Technical Appendices ASSESSMENT ABERDEEN HARBOUR EXPANSION PROJECT November 2015 Volume 3: Technical Appendices Appendix 20-C CONSTRUCTION NOISE ASSESSMENT 20-C CONSTRUCTION NOISE ASSESSMENT 20-C.1 CONSTRUCTION NOISE ASSESSMENT The

More information

Penn West Petroleum Ltd. Well Blowout W5M August 17, 2010

Penn West Petroleum Ltd. Well Blowout W5M August 17, 2010 Penn West Petroleum Ltd. Well Blowout 14-20-065-10W5M August 17, 2010 ERCB Investigation Report August 24, 2011 ENERGY RESOURCES CONSERVATION BOARD ERCB Investigation Report: Penn West Petroleum Ltd.,

More information

Decision D ATCO Electric Ltd. Decommissioning of Transmission Line 6L82

Decision D ATCO Electric Ltd. Decommissioning of Transmission Line 6L82 Decision 21447-D01-2016 August 23, 2016 Decision 21447-D01-2016 Proceeding 21447 Application 21447-A001 August 23, 2016 Published by the: Fifth Avenue Place, Fourth Floor, 425 First Street S.W. Calgary,

More information

Construction Noise Memorandum

Construction Noise Memorandum Construction Noise Memorandum To: Ms. Paula Daneluk Date: June 13, 2013 Development Impact 9370 Studio Court, Suite 160 Elk Grove, CA 95758 From: Paul Bollard Bollard Acoustical Consultants, Inc. 3551

More information

Mr. John Aitken June 6, 2017 Page 2

Mr. John Aitken June 6, 2017 Page 2 Mr. John Aitken June 6, 2017 Page 2 quarterly period of 2016. Fluctuations in noise exposure from reporting period to reporting period are to be expected due to ongoing changes in aircraft activity levels,

More information

RSPO RSPO NOTIFICATION OF PROPOSED NEW PLANTING

RSPO RSPO NOTIFICATION OF PROPOSED NEW PLANTING RSPO RSPO NOTIFICATION OF PROPOSED NEW PLANTING This notification shall be on the RSPO website for 30 days as required by the RSPO procedures for new plantings (http://www.rspo.org/?q=page/535). It has

More information

OPERATIONS NOISE STUDY FOR A PROPOSED AUTOMATIC CAR WASH IN THE SHERMAN OAKS DISTRICT OF LOS ANGELES

OPERATIONS NOISE STUDY FOR A PROPOSED AUTOMATIC CAR WASH IN THE SHERMAN OAKS DISTRICT OF LOS ANGELES OPERATIONS NOISE STUDY FOR A PROPOSED AUTOMATIC CAR WASH IN THE SHERMAN OAKS DISTRICT OF LOS ANGELES October 12, 2017 PREPARED FOR: Ms. Chantly Banayan 4822 Van Nuys Blvd. Sherman Oaks, CA 91403 PREPARED

More information

Frequently Asked Questions Directive 079: Surface Development in Proximity to Abandoned Wells

Frequently Asked Questions Directive 079: Surface Development in Proximity to Abandoned Wells Frequently Asked Questions Directive 079: Surface Development in Proximity to Abandoned Wells July 2018 General Q1. How can I determine if a well is abandoned? A1. A third party can see if it is abandoned

More information

Act 229 Evaluation Report

Act 229 Evaluation Report R22-1 W21-19 W21-20 Act 229 Evaluation Report Prepared for Prepared by Table of Contents 1. Documentation Page 3 2. Executive Summary 4 2.1. Purpose 4 2.2. Evaluation Results 4 3. Background 4 4. Approach

More information

Alberta Infrastructure HIGHWAY GEOMETRIC DESIGN GUIDE AUGUST 1999

Alberta Infrastructure HIGHWAY GEOMETRIC DESIGN GUIDE AUGUST 1999 &+$37(5Ã)Ã Alberta Infrastructure HIGHWAY GEOMETRIC DESIGN GUIDE AUGUST 1999 &+$37(5) 52$'6,'()$&,/,7,(6 7$%/(2)&217(176 Section Subject Page Number Page Date F.1 VEHICLE INSPECTION STATIONS... F-3 April

More information

Environmental Assessment for a New Landfill Footprint at the West Carleton Environmental Centre

Environmental Assessment for a New Landfill Footprint at the West Carleton Environmental Centre Waste Management of Canada Corporation Environmental Assessment for a New Landfill Footprint at the West Carleton Environmental Centre ATMOSPHERIC PARTICULATE MATTER EXISTING CONDITIONS REPORT Prepared

More information

Energy Technical Memorandum

Energy Technical Memorandum Southeast Extension Project Lincoln Station to RidgeGate Parkway Prepared for: Federal Transit Administration Prepared by: Denver Regional Transportation District May 2014 Table of Contents Page No. Chapter

More information

Lower River Floodplain Restoration and Levee/Towne Road Re-Alignment Noise Analysis

Lower River Floodplain Restoration and Levee/Towne Road Re-Alignment Noise Analysis Lower River Floodplain Restoration and Levee/Towne Road Re-Alignment Noise Analysis This project is not anticipated to create additional noise beyond the current background levels. Although Towne Road

More information

Alberta Electric System Operator Needs Identification Document Application. Mowat 2033S Substation

Alberta Electric System Operator Needs Identification Document Application. Mowat 2033S Substation Decision 21781-D01-2016 Alberta Electric System Operator Needs Identification Document Application Facility Applications September 7, 2016 Alberta Utilities Commission Decision 21781-D01-2016: Alberta

More information

Abstract. General N BANDA

Abstract. General N BANDA Abstract General For mining operations, both underground and open cast, there are generally accepted criteria used to arrive at the optimum mining method with which to exploit the ore body economically.

More information

Appendix C Noise and Vibration Worksheets

Appendix C Noise and Vibration Worksheets PUBLIC WORKS BUREAU OF ENGINEERING Appendix C Noise and Vibration Worksheets Central Outfall Sewer at 59 th Street Page C-1 CEQA Initial Study and 4 th Avenue Project January 2012 Receptor Noise Level

More information

Existing and Proposed Canadian Commercial Oil Sands Projects. February 2009

Existing and Proposed Canadian Commercial Oil Sands Projects. February 2009 Existing and Proposed Canadian Commercial Oil Sands Projects February 2009 www.strategywest.com Prepared by: R.B. (Bob) Dunbar, P.Eng. bob.dunbar@strategywest.com Copyright Strategy West Inc. 2009 No part

More information

STUDY ON EURO 5 SOUND LEVEL LIMITS OF L-CATEGORY VEHICLES

STUDY ON EURO 5 SOUND LEVEL LIMITS OF L-CATEGORY VEHICLES Transmitted by the expert from the European Commission Informal document GRB-66-15 (66th GRB, 4-6 September 2017, agenda item 10) STUDY ON EURO 5 SOUND LEVEL LIMITS OF L-CATEGORY VEHICLES 66 th GRB meeting,

More information

REPORT No EN-S AJ

REPORT No EN-S AJ Pollution Control Consultancy and Design ALEX JOCHELSON ABN 71 776 800 318 MEMech MIEAust CPEng ( Reg ) Air, Noise and Water Pollution Assessment and Engineering Control Telephone: (02) 9238 2053 Facsimile:

More information

CITY OF MINNEAPOLIS GREEN FLEET POLICY

CITY OF MINNEAPOLIS GREEN FLEET POLICY CITY OF MINNEAPOLIS GREEN FLEET POLICY TABLE OF CONTENTS I. Introduction Purpose & Objectives Oversight: The Green Fleet Team II. Establishing a Baseline for Inventory III. Implementation Strategies Optimize

More information

Acoustics Noise Vibration

Acoustics Noise Vibration Acoustics Noise Vibration Grand Bend Wind Farm Page 2 of 17 Environmental Noise Impact Assessment April 15, 2014 Executive Summary The purpose of this environmental noise impact assessment, prepared for

More information

The following section summarises the present conditions related to transportation for the proposed development of the Matimba B Power Station:

The following section summarises the present conditions related to transportation for the proposed development of the Matimba B Power Station: 14. TRAFFIC AND TRANSPORT 14.1. Status Quo Conditions The following section summarises the present conditions related to transportation for the proposed development of the Matimba B Power Station: 14.1.1.

More information

REAL WORLD DRIVING. Fuel Efficiency & Emissions Testing. Prepared for the Australian Automobile Association

REAL WORLD DRIVING. Fuel Efficiency & Emissions Testing. Prepared for the Australian Automobile Association REAL WORLD DRIVING Fuel Efficiency & Emissions Testing Prepared for the Australian Automobile Association - 2016 2016 ABMARC Disclaimer By accepting this report from ABMARC you acknowledge and agree to

More information

TABLE OF CONTENTS SECTION TITLE PAGE NUMBER

TABLE OF CONTENTS SECTION TITLE PAGE NUMBER WORKER FATALLY INJURED IN HAUL TRUCK COLLISION IN MINE Type of Incident: Fatality Date of Incident: November 23, 2009 TABLE OF CONTENTS SECTION TITLE PAGE NUMBER 1.0 DATE AND TIME OF INCIDENT 3 2.0 NAME

More information

Silverado Village Project

Silverado Village Project Environmental Noise Assessment Silverado Village Project Elk Grove, California BAC Job # 2011-053 Prepared For: Vintara Holdings, LLC Attn: Mr. Paul Eblen 140 Diamond Creek Place Roseville, CA 95747 Prepared

More information

Currant Lake Transmission Project

Currant Lake Transmission Project Currant Lake Transmission Project September 2010 Why are you receiving this project information package? New transmission facilities are needed in the Monitor area of southeastern Alberta. ATCO Electric

More information

I101 Motorsport Precinct

I101 Motorsport Precinct I101. Motorsport I101.1. Precinct description The Motorsport Precinct applies to three of Auckland s motorsport parks: Colin Dale Park; Rosebank Road; and Waikaraka Park. The precinct does not include

More information

Public Information Centre

Public Information Centre Junction Street Wastewater Pumping Station & Forcemain Schedule B Municipal Class Environmental Assessment Study Public Information Centre June 28, 2017. 6:00 to 8:00 pm. The Burlington Performing Arts

More information

China Proposal for Micro-Van and Micro-Truck

China Proposal for Micro-Van and Micro-Truck China Proposal for Micro-Van and Micro-Truck Informal document GRB-60-10-Rev.1 (60th GRB, 1-3 September 2014, agenda item 4(a)) Micro-van and Micro-truck : GVM 2.5 ton R-point height 800mm from the ground

More information

Frequently Asked Questions

Frequently Asked Questions Frequently Asked Questions Directive 040 General December 2016 Q1. How do I apply for exemptions to Directive 040 test requirements? A1. Contact the AER Well Test Group by email at welltest-helpline@aer.ca

More information

Table Existing Traffic Conditions for Arterial Segments along Construction Access Route. Daily

Table Existing Traffic Conditions for Arterial Segments along Construction Access Route. Daily 5.8 TRAFFIC, ACCESS, AND CIRCULATION This section describes existing traffic conditions in the project area; summarizes applicable regulations; and analyzes the potential traffic, access, and circulation

More information

Decision D ATCO Electric Ltd. Decommissioning of Transmission Line 6L79. October 18, 2016

Decision D ATCO Electric Ltd. Decommissioning of Transmission Line 6L79. October 18, 2016 Decision 21481-D01-2016 October 18, 2016 Alberta Utilities Commission Decision 21481-D01-2016 Proceeding 21481 Application 21481-A001 October 18, 2016 Published by the: Alberta Utilities Commission Fifth

More information

WOLVERINE TO BHP JANSEN NEW TRANSMISSION LINE PROJECT FALL 2017

WOLVERINE TO BHP JANSEN NEW TRANSMISSION LINE PROJECT FALL 2017 WOLVERINE TO BHP JANSEN NEW TRANSMISSION LINE PROJECT FALL 2017 TODAY WE LL TALK ABOUT Our challenges and how we re meeting them Why we re building this project Our planning process and considerations

More information

Appendix D. Noise Calculations

Appendix D. Noise Calculations Appendix D Noise Calculations Summary of Boating Activity Changes Associated with each Alternative Peak Day Boating Trips Structure Existing With Alt increase with alt 2 increase with alt 3 increase with

More information

DRIVER SPEED COMPLIANCE WITHIN SCHOOL ZONES AND EFFECTS OF 40 PAINTED SPEED LIMIT ON DRIVER SPEED BEHAVIOURS Tony Radalj Main Roads Western Australia

DRIVER SPEED COMPLIANCE WITHIN SCHOOL ZONES AND EFFECTS OF 40 PAINTED SPEED LIMIT ON DRIVER SPEED BEHAVIOURS Tony Radalj Main Roads Western Australia DRIVER SPEED COMPLIANCE WITHIN SCHOOL ZONES AND EFFECTS OF 4 PAINTED SPEED LIMIT ON DRIVER SPEED BEHAVIOURS Tony Radalj Main Roads Western Australia ABSTRACT Two speed surveys were conducted on nineteen

More information

Table City of Glendora Predicted Vibration Levels for Residential (Category 2) Land Uses

Table City of Glendora Predicted Vibration Levels for Residential (Category 2) Land Uses Table 3.11-11. City of Glendora Predicted Vibration Levels for Residential (Category 2) Land Uses Cluster Number 1 Cross Streets Direction Distance (feet) 2 Train Speed (mph) Threshold (VdB) Predicted

More information

Nation Rise Wind Farm Limited Partnership

Nation Rise Wind Farm Limited Partnership NATION RISE WIND FARM Renewable Energy Approval Application - Noise Impact Assessment Nation Rise Wind Farm Limited Partnership Document No.: 10021027-CAMO-R-06 Issue: A, Status: Draft Date: 15 March 2017

More information

Attachment E3 Vibration Technical Memorandum

Attachment E3 Vibration Technical Memorandum Attachment E3 Technical Memorandum 77 South Bedford Street Burlington, MA 01803 T 781.229.0707 F 781.229.7939 E jross@hmmh.com W www.hmmh.com TECHNICAL MEMORANDUM To: Alisa Swank, CH2M HILL Jodi Ketelsen,

More information

Decision Blaze Energy Ltd. Application for an Exemption under Section 24 of the Hydro and Electric Energy Act.

Decision Blaze Energy Ltd. Application for an Exemption under Section 24 of the Hydro and Electric Energy Act. Decision 2014-108 Application for an Exemption under Section 24 of the Hydro and Electric Energy Act April 17, 2014 The Alberta Utilities Commission Decision 2014-108: Application for an Exemption under

More information

Report Addendum. Terry Keller, SDDOT. Noise Study Technical Report I-29 from Tea Interchange to Skunk Creek Sioux Falls, South Dakota

Report Addendum. Terry Keller, SDDOT. Noise Study Technical Report I-29 from Tea Interchange to Skunk Creek Sioux Falls, South Dakota Report Addendum To: Terry Keller, SDDOT From: HDR Project: Noise Study Technical Report I-29 from Tea Interchange to Skunk Creek Sioux Falls, South Dakota cc: file Date: May 28, 2010; rev July 16, July

More information

November 14, 2016 Reference No

November 14, 2016 Reference No November 14, 2016 Reference No. 11115752 Mr. Andrew Booth Engineering Services City Service Centre 9505-112 Grande Prairie, Alberta T8V 6H8 Dear Mr. Booth: Re: 2016 Arterial Traffic Noise Survey City of

More information

Acoustics Noise Vibration

Acoustics Noise Vibration Acoustics Noise Vibration environmental noise impact assessment project number: 11167 Grand Bend Wind Farm Grand Bend, ON Grand Bend Wind Limited Partnership Northland Power Inc., as agent Prepared for:

More information

Parks and Transportation System Development Charge Methodology

Parks and Transportation System Development Charge Methodology City of Sandy Parks and Transportation System Development Charge Methodology March, 2016 Background In order to implement a City Council goal the City of Sandy engaged FCS Group in January of 2015 to update

More information

Shadow Flicker Briefing

Shadow Flicker Briefing Wind Farm Measurements and Modeling Shadow Flicker Briefing Subject: Customer: Project type: Prepared by: Distribution: Shadow-Flicker Modeling Clayton, NY. PPM Atlantic Renewable 330 Province Line Road

More information

Federal Railroad Administration, DOT CFR section Description Guideline PART 179

Federal Railroad Administration, DOT CFR section Description Guideline PART 179 Federal Railroad Administration, DOT 210.3 PENALTY ASSESSMENT GUIDELINES Continued 49 CFR section Description Guideline PART 179 179.1(e)... Tank car not constructed according to specifications also cite

More information

Residential Load Profiles

Residential Load Profiles Residential Load Profiles TABLE OF CONTENTS PAGE 1 BACKGROUND... 1 2 DATA COLLECTION AND ASSUMPTIONS... 1 3 ANALYSIS AND RESULTS... 2 3.1 Load Profiles... 2 3.2 Calculation of Monthly Electricity Bills...

More information

Joint Operating Procedures for First Nations Consultation on Energy Resource Activities

Joint Operating Procedures for First Nations Consultation on Energy Resource Activities Joint Operating Procedures for First Nations Consultation on Energy Resource Activities October 31, 2018 Contents Revision History... iv Definitions of Key Terms... v 1 Background... 1 2 Roles and Responsibilities...

More information

Yukon s Independent Power Production Policy

Yukon s Independent Power Production Policy Yukon s Independent Power Production Policy Updated October 2018 BACKGROUND The Government of Yukon (YG) released the Energy Strategy for Yukon in January 2009. The strategy sets out YG s energy priorities,

More information

A member-consumer with a QF facility shall not participate in the Cooperative s electric heat rate program.

A member-consumer with a QF facility shall not participate in the Cooperative s electric heat rate program. Electric Tariff _2nd Revised Sheet No. 72 Filed with Iowa Utilities Board Cancels _1st Sheet No. _72 Cooperative is a member of Central Iowa Power Cooperative (CIPCO), a generation and transmission cooperative

More information

BORAL CONCRETE GLENORIE

BORAL CONCRETE GLENORIE BORAL CONCRETE GLENORIE > Glenorie Progress Association meeting 14 March 2018 Glenorie RSL Club Glenorie A recap of our last discussion (Oct 2017)... Who are we? Boral Concrete (NSW/ACT) is part of the

More information

COMMISSION REGULATION (EC)

COMMISSION REGULATION (EC) L 191/26 Official Journal of the European Union 23.7.2009 COMMISSION REGULATION (EC) No 640/2009 of 22 July 2009 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard

More information

EN 1 EN. Second RDE LDV Package Skeleton for the text (V3) Informal EC working document

EN 1 EN. Second RDE LDV Package Skeleton for the text (V3) Informal EC working document Second RDE LDV Package Skeleton for the text (V3) Informal EC working document Introduction This document is a skeleton of the intended second RDE package. The document identifies which sections-appendices

More information

REPEATABILITY OF CPX TYRE/ROAD NOISE MEASUREMENTS. Gillian Adams, Frits Kamst and Stephen Pugh ASK Consulting Engineers, Brisbane, Australia

REPEATABILITY OF CPX TYRE/ROAD NOISE MEASUREMENTS. Gillian Adams, Frits Kamst and Stephen Pugh ASK Consulting Engineers, Brisbane, Australia ICSV14 Cairns Australia 9-12 July, 2007 REPEATABILITY OF CPX TYRE/ROAD NOISE MEASUREMENTS Gillian Adams, Frits Kamst and Stephen Pugh ASK Consulting Engineers, Brisbane, Australia frits@askce.com ABSTRACT

More information

Adelaide Wind Power Project Turbine T05 (AD117) IEC Edition 3.0 Measurement Report

Adelaide Wind Power Project Turbine T05 (AD117) IEC Edition 3.0 Measurement Report REPORT ID: 14215.01.T05.RP6 Adelaide Wind Power Project Turbine T05 (AD117) IEC 61400-11 Edition 3.0 Measurement Report Prepared for: Suncor Adelaide Wind General Partnership Inc. 2489 North Sheridan Way

More information

ENERGY STRATEGY FOR YUKON. Independent Power Production Policy

ENERGY STRATEGY FOR YUKON. Independent Power Production Policy ENERGY STRATEGY FOR YUKON Independent Power Production Policy May 20, 2014 Page 2 of 11 BACKGROUND The Government of Yukon released the Energy Strategy for Yukon in January 2009. The strategy sets out

More information

Directivity of the CoRTN road traffic noise model

Directivity of the CoRTN road traffic noise model Proceedings of th International Congress on Acoustics, ICA 10 23-27 August 10, Sydney, Australia Directivity of the CoRTN road traffic noise model Simon Moore, Matthew Stead and Jonathan Cooper AECOM,

More information

ENVIRONMENTAL IMPACT STATEMENT

ENVIRONMENTAL IMPACT STATEMENT RED HILL MINING LEASE ENVIRONMENTAL IMPACT STATEMENT Section 14 Transport Section 14 Transport 14.1 Description of Environmental Values This section of the Red Hill Mining Lease Environmental Impact Statement

More information

Craig Scheffler, P.E., PTOE HNTB North Carolina, P.C. HNTB Project File: Subject

Craig Scheffler, P.E., PTOE HNTB North Carolina, P.C. HNTB Project File: Subject TECHNICAL MEMORANDUM To Kumar Neppalli Traffic Engineering Manager Town of Chapel Hill From Craig Scheffler, P.E., PTOE HNTB North Carolina, P.C. Cc HNTB Project File: 38435 Subject Obey Creek TIS 2022

More information

Transit Vehicle (Trolley) Technology Review

Transit Vehicle (Trolley) Technology Review Transit Vehicle (Trolley) Technology Review Recommendation: 1. That the trolley system be phased out in 2009 and 2010. 2. That the purchase of 47 new hybrid buses to be received in 2010 be approved with

More information

Copyright Statement FPC International, Inc

Copyright Statement FPC International, Inc Copyright Statement All rights reserved. All material in this document is, unless otherwise stated, the property of FPC International, Inc. Copyright and other intellectual property laws protect these

More information

Copyright Statement FPC International, Inc

Copyright Statement FPC International, Inc Copyright Statement All rights reserved. All material in this document is, unless otherwise stated, the property of FPC International, Inc. Copyright and other intellectual property laws protect these

More information

Ambient PM 10 Monitoring Sechelt, B.C Update

Ambient PM 10 Monitoring Sechelt, B.C Update Ministry of Environment LOWER MAINLAND REGION Ambient PM 10 Monitoring Sechelt, B.C. 2004-2005 Update E N V I R O N M E N T A L Q U A L I T Y Library and Archives Canada Cataloguing in Publication Data

More information

DECEMBER 15-18, 1997 ADELAIDE, SOUTH AUSTRALIA. Y. K. Tso and R. G. Juniper

DECEMBER 15-18, 1997 ADELAIDE, SOUTH AUSTRALIA. Y. K. Tso and R. G. Juniper FIFTH INTERNATIONAL CONGRESS ON SOUND AND VIBRATION DECEMBER 15-18, 1997 ADELAIDE, SOUTH AUSTRALIA Invited Paper A STUDY OF THE TRANSMISSION OF NOISE AND VIBRATION IN AN ALUMINIUM MOTOR VESSEL Y. K. Tso

More information

The Township Guide to Parking Restrictions

The Township Guide to Parking Restrictions January 2015 INTRODUCTION What are parking restrictions? They are restrictions that are established on a road which modifies what type of parking is allowed on the road. There are different types of restrictions

More information

TIMBERVINE TRANSPORTATION IMPACT STUDY FORT COLLINS, COLORADO JANUARY Prepared for:

TIMBERVINE TRANSPORTATION IMPACT STUDY FORT COLLINS, COLORADO JANUARY Prepared for: TIMBERVINE TRANSPORTATION IMPACT STUDY FORT COLLINS, COLORADO JANUARY 2014 Prepared for: Hartford Companies 1218 W. Ash Street Suite A Windsor, Co 80550 Prepared by: DELICH ASSOCIATES 2272 Glen Haven Drive

More information

A CO2 based indicator for severe driving? (Preliminary investigations - For discussion only)

A CO2 based indicator for severe driving? (Preliminary investigations - For discussion only) A CO2 based indicator for severe driving? (Preliminary investigations - For discussion only) A case study Diesel vehicle tested with PEMS on the JRC test routes : Route 1: Rural-Motorway Route 2: City

More information

RULE STATIONARY GAS TURBINES Adopted (Amended , ) INDEX

RULE STATIONARY GAS TURBINES Adopted (Amended , ) INDEX RULE 413 - STATIONARY GAS TURBINES Adopted 04-06-95 (Amended 05-01-97, 03-24-05) INDEX 100 GENERAL 101 PURPOSE 102 APPLICABILITY 110 EXEMPTION - EMERGENCY STANDBY UNITS 111 EXEMPTION - REMOVAL FROM SERVICE

More information

Compatibility Between Electric Trains and Electrification Systems

Compatibility Between Electric Trains and Electrification Systems Compatibility Between Electric Trains and Electrification Systems Synopsis Process for managing change that affects the compatibility between electric trains and electrification systems Submitted by Signatures

More information

CMEIG ADVISORY NOTICE RATED LOADS FOR WHEEL LOADERS

CMEIG ADVISORY NOTICE RATED LOADS FOR WHEEL LOADERS CMEIG ADVISORY NOTICE Disclaimer: CMEIG is a non-profit organization sponsored by companies involved in the supply of products and services in the construction and mining equipment industry in Australia.

More information

Effectiveness of ECP Brakes in Reducing the Risks Associated with HHFT Trains

Effectiveness of ECP Brakes in Reducing the Risks Associated with HHFT Trains Effectiveness of ECP Brakes in Reducing the Risks Associated with HHFT Trains Presented To The National Academy of Sciences Review Committee October 14, 2016 Slide 1 1 Agenda Background leading to HM-251

More information

RULES PUBLICATION NO. 98/P

RULES PUBLICATION NO. 98/P RULES PUBLICATION NO. 98/P GUIDELINES REGARDING THE REQUIREMENTS FOR MARINE DIESEL ENGINES FITTED WITH NO X SELECTIVE CATALYTIC REDUCTION (SCR) SYSTEMS 2016 January Publications P (Additional Rule Requirements)

More information

REGIONAL DISTRICT OF OKANAGAN-SIMILKAMEEN BYLAW NO , A Bylaw to amend the Electoral Area H Zoning Bylaw No.

REGIONAL DISTRICT OF OKANAGAN-SIMILKAMEEN BYLAW NO , A Bylaw to amend the Electoral Area H Zoning Bylaw No. BYLAW NO. 2498.08 REGIONAL DISTRICT OF OKANAGAN-SIMILKAMEEN BYLAW NO. 2498.08, 2016 A Bylaw to amend the Electoral Area H Zoning Bylaw No. 2498, 2012 The REGIONAL BOARD of the Regional District of Okanagan-Similkameen

More information

June Safety Measurement System Changes

June Safety Measurement System Changes June 2012 Safety Measurement System Changes The Federal Motor Carrier Safety Administration s (FMCSA) Safety Measurement System (SMS) quantifies the on-road safety performance and compliance history of

More information