PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION

Size: px
Start display at page:

Download "PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION"

Transcription

1 Engineering Specification Track L1-CHE-SPE-064 Ballast Supply Version: 1 Issued: October 2015 Owner: Engineering Group Approved By: Gordon Djurdjevic Track Engineering Manager PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION

2 Approval Amendment Record Approval Date Version Description 01/10/ Initial issue. Supersedes previous document L2-INF-SAS-002 PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION Page 2 of 10

3 Table of Contents 1 Purpose Scope Abbreviations Definitions References & Legislations Responsibilities Safety & Environmental Requirements Naming Convention for Ordering Ballast Manufacture of Railway Ballast General Material Properties Rejection of Proposed Ballast Material Sampling and Testing of Ballast Testing for Conformity Production Testing Inspection of Facilities Manufacture of Screening Used as Ballast General Material Properties mm Screenings Grading Table Testing of Screenings Ballast Handling Ballast Delivery Ballast Stockpiling Ballast Loading Related Documents Records Appendices PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION Page 3 of 10

4 1 Purpose This specification sets out requirements for the supply, manufacturing, testing and handling of Ballast. 2 Scope This specification will cover the requirements for the supply of Ballast used for Contract purposes. 3 Abbreviations MTM QA Metro Trains Melbourne Quality Assurance 4 Definitions Australian Standard Ballast Nominal Size Superintendent Standards Published by Standards Australia. Ballast is a free draining coarse aggregate used to support railway tracks. The designation of an aggregate which gives an indication of the largest size particle present. Technical Representative nominated by the Chief Engineer s Office. 5 References & Legislations AS Aggregates and rock for engineering purposes Part 7: Railway Ballast AS1141 Methods for sampling and testing of aggregates 6 Responsibilities The Contractor shall be responsible for conformance to this document. The MTM Technical Representative nominated by the Chief Engineer s Office shall be responsible for the management of the technical requirements and shall ensure compliance in accordance with the MTM documented processes relevant to this specification. PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION Page 4 of 10

5 7 Safety & Environmental The general requirements in relation to safety are included in MTM s Safety Management System Manual (L0-SQE-MAN-002). L0-SQE-PRO-014 Safety and Environmental Requirements for Contractors Working on MTM Premises outline the requirements of contractors operating within MTM s premises. 8 Requirements 8.1 Naming Convention for Ordering Ballast Under the former PTC naming convention, there were two gradings of ballast: 53mm and 37mm. Under the naming convention in AS2758.7, there are also two gradings of ballast: 60mm and 50mm. These have now superseded the 53mm and 37mm gradings respectively. Therefore: A requirement for traditional 53mm ballast or 60mm nominal ballast shall be met by supply of 60mm nominal ballast to Table 1 in AS A requirement for traditional 37mm ballast or 50mm nominal ballast shall be met by supply of 50mm nominal ballast to Table 1 in AS Important Note: The 60mm graded aggregate also in Table 1 in AS is not to be used as a railway ballast as part of MTM procedures. 8.2 Manufacture of Railway Ballast General The whole of the material supplied shall be basalt or other approved rock and shall be clean, free from clay, dirt and other deleterious matter or weathered pieces of rock and free from dust. Material Properties Material supplied shall generally be in accordance with AS Aggregates and rock for engineering purposes - Part 7: Railway ballast except that the limiting values for the tests required to be carried out to AS 1141 Method for sampling and testing aggregates plus any additional tests required by this specification shall be as defined in Table 1. Rejection of Proposed Ballast Material Igneous or other rock, displaying minerals considered to be harmful to the overall performance of the ballast may be rejected following petrographic analysis or durability testing, even though the rock complies with other sections of the specification. PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION Page 5 of 10

6 AS1141 Part: Title Property Limiting Value 4 Bulk Density of Aggregate bulk density >1200 kg/m³ 6 Particle density and water absorption of coarse aggregate - Weighing-in-water particle density >2600 kg/m³ method. 11 Particle size distribution by sieving. grading Use Table 1 in AS Particle Shape, by Proportional Calliper <30% Mis-shapen particles (+ Amendment 2:1 calliper ratio 15 Flaky particles in ballast material retained on 6.70 mm sieve Flakiness Index <30% 21 Aggregate crushing value (passing 26.5 mm sieve and retained on 19.0 mm sieve) 22 Wet/dry strength variation crushing value <25% wet strength wet/dry strength variation >175 kn <25% Los Angeles Value (+ Amendment No.1) resistance to abrasion <25% Resistance to wear by attrition (passing 53.0 mm sieve and retained on 37.5 mm sieve). wet attrition value <6% Weak Particles (including clay lumps, soft and friable particles) in Coarse Aggregates. weak particles <0.3% Table Sampling and Testing of Ballast Unless otherwise specified below sampling and testing shall be carried out in accordance with the requirements of AS and the AS 1141 series of Standards. The Superintendent arranging supply of ballast shall obtain certification from suppliers for all new ballast supplied from: Quarries not previously used for the supply of Railway Ballast to this specification. Existing quarries used for the supply of Railway Ballast to this specification where the material being quarried changes. An independent party who shall be an approved member of the National Association of Testing Authorities (NATA) shall carry out the sampling and testing. Certification shall include documentation that the ballast has been sampled and tested in accordance with, and meets the requirements of this specification. The test report from the sampling and testing authority shall be submitted to MTM, even where this specification is not met Testing for Conformity A sample from the first 100 m3 of ballast produced shall be tested for full conformity with this technical specification, except when this requirement is waived by MTM. QA Records for all tests undertaken shall be stored on file by the Contractor and shall be made available upon request by the Superintendent. MTM may require additional sampling and testing where MTM suspects that the material is not to specification. PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION Page 6 of 10

7 Production Testing Production testing shall comprise: Particle size distribution testing, sampled at least once from each 1,000 m3 (1,500T) of ballast produced; Testing for misshapen particles, sampled at least once from each 1,000 m3 (1,500T) of ballast produced; Testing for flaky particles, sampled at least once from each 1,000 m3 (1500T) of ballast produced; and Testing for full conformity with this technical specification, sampled at least once from each 10,000 m3 (15,000T) of ballast produced, except where this requirement is waived by MTM. Sampling for production testing shall take place from ballast that has been delivered in accordance with the supply contract. QA Records for all production testing shall be stored on file by the Contractor and shall be made available upon request by the Superintendent. Inspection of Facilities MTM shall be provided access to inspect ballast production facilities at any unscheduled time during normal working hours for the purpose of: Observing sampling and testing procedures. Review plant and ballast production facilities. Carry out any additional sampling and testing. The Superintendent shall ensure that contracts with Sub-contractors provide for these inspections. 8.4 Manufacture of Screening Used as Ballast General Where approval has been given to use screenings as track ballast due to certain local conditions (e.g. concrete bridge deck with only shallow depths available for ballast), screenings shall be nominal 19mm screenings. The whole of the 19mm screenings supplied shall be basalt or other approved rock and shall be clean, free from clay, dirt and other deleterious matter or weathered pieces of rock and free from dust. Material Properties Material supplied shall generally be in accordance with AS Aggregates and rock for engineering purposes - Part 7: Railway ballast except that the limiting values for the tests required to be carried out to AS 1141 Method for sampling and testing aggregates shall be as follows: PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION Page 7 of 10

8 AS1141 Title Property Property Limiting Value Part 6 Particle density and water absorption of particle density >2500 kg/m³ coarse aggregate - Weighing-in-water method. 11 Particle size distribution by sieving. grading Use 19mm Screenings Table (below). 14 Particle Shape, by Proportional Calliper (+ Amendment No.1) mis-shapen particles 2:1 calliper ratio 23 Los Angeles Value resistance to abrasion <25% (+ Amendment No.1) 32 Weak Particles (including clay lumps, soft and friable particles) in Coarse Aggregates. weak particles <0.3% mm Screenings Grading Table Standard Sieve Size Percentage by Weight Passing A.S. Sieves (mm) % % 30-50% 0-15% 0-5% 0-1% 8.5 Testing of Screenings For screenings, tests to AS1141 parts 6, 11, 14, 23 & 32 shall be carried out. 8.6 Ballast Handling Ballast Delivery Prepared ballast shall be handled at the producing plant in such a manner that it is kept clean and free from segregation. Vehicles used for transportation shall be clean and free from rubbish and substances which may foul or damage the ballast. Ballast Stockpiling The Superintendent shall arrange for the management of ballast. MTM supplied ballast shall be maintained separately from any Contractors ballast. This shall include physical separation as well as separation of stockpile usage record keeping. When ballast is removed from stockpile for distribution into track, it shall conform to the same specification requirements defined in Section PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION Page 8 of 10

9 Ballast distributed into track, which does not meet the specified quality requirements shall be removed and replaced. Ballast shall be stored stockpiled and handled in conditions which prevent material contamination, segregation and degradation. The movement of machinery over the stockpiled ballast shall be limited to minimize any degradation Ballast Loading The Superintendent shall ensure that there is a procedure for loading ballast and recording amount loaded including: Loading equipment to be used. Method of measuring loaded amounts of ballast. Loading Process. The loading process shall include provisions for: Minimising wastage of ballast. Avoiding unnecessary handling which may degrade the ballast in any manner by: Repeated mechanical handling. Unnecessary dropping of material. Contamination from the base of stockpiles or other sources. Ballast loading records shall be maintained based on one of the following methods: Measured weights (using certified loading scales) of the loaded hoppers or of the ballast passing through the device used to load the ballast directly into the hoppers or by truck and delivered to site, as directed by the Superintendent. Average weight agreements for each type of ballast hopper in the loaded condition. Ballast shall only be transported in accredited ballast hoppers, in trains operated by an accredited Operator, or by truck and delivered to site, as directed by the Superintendent. Ballast shall be loaded in a safe and environmentally acceptable manner particularly with regard to dust nuisance and noise levels. 9 Related Documents N/A PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION Page 9 of 10

10 10 Records QA records detailing the conformance of ballast to this specification shall be maintained by the Contractor. These records shall be made available to MTM upon request by the Superintendent. QA records shall detail the individual tests used to demonstrate conformance to this specification, production tests and the results produced by each of these tests. 11 Appendices N/A PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION Page 10 of 10

Class 1 Crushed rock ballast for use primarily on main line track. Class 2 Crushed rock ballast for use only on other than main line track.

Class 1 Crushed rock ballast for use primarily on main line track. Class 2 Crushed rock ballast for use only on other than main line track. PAGE 1 OF 8 PART 1 - GENERAL REQUIREMENTS 1.1 DESCRIPTION OF SPECIFICATION This document outlines the material, stockpiling, and handling specifications of ballast. It covers the supply of ballast from

More information

PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION

PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION Engineering Standard Track Vehicles Version: 8 Issued: December 2016 Owner: Chief Engineer Approved By: Phil Ellingworth Chief Engineer PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST

More information

DIVISION III MATERIALS AGGREGATES SECTION 901 COARSE AGGREGATE

DIVISION III MATERIALS AGGREGATES SECTION 901 COARSE AGGREGATE DIVISION III MATERIALS AGGREGATES SECTION 901 COARSE AGGREGATE 901-1 General. 901-1.1 Composition: Coarse aggregate shall consist of naturally occurring materials such as gravel, or resulting from the

More information

Summary of Administrative Revisions to Standard Specifications 700 Series Description of Revision

Summary of Administrative Revisions to Standard Specifications 700 Series Description of Revision Summary of Administrative Revisions to Standard Specifications 700 Series Section Description of Revision ALL Formatting in accordance with CSI standards o All Paragraphs identified by a letter Sub-paragraphs

More information

MESP TECHNICAL SPECIFICATION FOR A STATIONARY CONTROL BATTERY AND CHARGER SET FOR USE IN A SUBSTATION

MESP TECHNICAL SPECIFICATION FOR A STATIONARY CONTROL BATTERY AND CHARGER SET FOR USE IN A SUBSTATION Engineering Specification Electrical Networks TECHNICAL SPECIFICATION FOR A STATIONARY CONTROL BATTERY AND CHARGER SET FOR USE IN A SUBSTATION Version: 2 Issued: August 2016 Owner: Head of Engineering

More information

Geoscience Testing laboratory (Al Ain)

Geoscience Testing laboratory (Al Ain) Soil 1 In-situ Density by Sand Replacement Method Using Large Pouring Cylinder & Small Pouring Cylinder In-place Density Test by Sand Cone Method BS 1 Part ASTM D 1556 Dry Density Moisture Content Relationship

More information

MCST LIGHTING AND POWER DESIGN AND CONSTRUCTION

MCST LIGHTING AND POWER DESIGN AND CONSTRUCTION Engineering Standard- Design Structures & Facilities MCST 000002-01 Version: 3 Issued: May 2016 Owner: Chief Engineer Approved By: Phil Ellingworth Chief Engineer PRINTOUT MAY NOT BE UP-TO-DATE; REFER

More information

VOLUNTARY CODE OF PRACTICE FOR ELECTROMAGNETIC COMPATIBILITY (EMC) OF MOTOR VEHICLES (13 October 2014)

VOLUNTARY CODE OF PRACTICE FOR ELECTROMAGNETIC COMPATIBILITY (EMC) OF MOTOR VEHICLES (13 October 2014) FEDERAL CHAMBER OF AUTOMOTIVE INDUSTRIES VOLUNTARY CODE OF PRACTICE FOR ELECTROMAGNETIC COMPATIBILITY (EMC) OF MOTOR VEHICLES (13 October 2014) This code is prepared under the direction of the FCAl Board,

More information

HA Thickness Gauge IS:2386 (part 1)- 1963

HA Thickness Gauge IS:2386 (part 1)- 1963 AGGREGATE TESTING HA50.05 Mechanical Rotating Sample Divider (Motorised) IS : 1607-1960 For obtaining representative sample for sieve analysis. It is suitable for dry sands, fine powders, ores, refractory

More information

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR PAVEMENT RIDE QUALITY (MEAN ROUGHNESS INDEX ACCEPTANCE CRITERIA)

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR PAVEMENT RIDE QUALITY (MEAN ROUGHNESS INDEX ACCEPTANCE CRITERIA) MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR PAVEMENT RIDE QUALITY (MEAN ROUGHNESS INDEX ACCEPTANCE CRITERIA) CFS:TEH 1 of 10 APPR:KPK:JFS:07-07-16 FHWA:APPR:07-15-16 a. Description. This

More information

Rapid Response. Lineside Signal Spacing. Railway Group Standard GK/RT0034 Issue Three Date September 1998

Rapid Response. Lineside Signal Spacing. Railway Group Standard GK/RT0034 Issue Three Date September 1998 Rapid Response Railway Group Standard Lineside Signal Spacing Synopsis This Standard specifies the minimum distance that must be provided between the first signal displaying a cautionary aspect and the

More information

E/ECE/324/Rev.2/Add.102/Rev.1 E/ECE/TRANS/505/Rev.2/Add.102/Rev.1

E/ECE/324/Rev.2/Add.102/Rev.1 E/ECE/TRANS/505/Rev.2/Add.102/Rev.1 30 August 2011 Agreement Concerning the adoption of uniform technical prescriptions for wheeled vehicles, equipment and parts which can be fitted and/or be used on wheeled vehicles and the conditions for

More information

Mattest (Ireland) Ltd

Mattest (Ireland) Ltd Unit 2, Northwest Business Park, Ballycoolin, Dublin 15 Testing Laboratory Registration number: 286T is accredited by the Irish National Board (INAB) to undertake testing as detailed in the Schedule bearing

More information

TITLE: SPECIFICATION FOR BENCH VICE & BENCH GRINDER TABLE OF CONTENTS. 0.1 Circulation List. 0.2 Amendment Record

TITLE: SPECIFICATION FOR BENCH VICE & BENCH GRINDER TABLE OF CONTENTS. 0.1 Circulation List. 0.2 Amendment Record Page 1 of 10 TABLE OF CONTENTS 0.1 Circulation List 0.2 Amendment Record FOREWORD 1. SCOPE 2. REFERENCES 3. TERMS AND DEFINITIONS 4. REQUIREMENTS 5. TESTS AND INSPECTION 6. MARKING AND PACKING 7. DEMONSTRATION

More information

CIMEC Technologies Pvt. Ltd., 23/H, Meldi Estate, Gota, Ahmedabad, Gujarat. Discipline Mechanical Testing Issue Date

CIMEC Technologies Pvt. Ltd., 23/H, Meldi Estate, Gota, Ahmedabad, Gujarat. Discipline Mechanical Testing Issue Date Last Amended on - Page 1 of 9 I. BUILDINGS MATERIALS 1. Cement & Pozzolanic Material Fineness (Dry Sieving) IS 4031(Part 1): 1996 (RA 2011) 10 % to 100 % Fineness (Blain Air Permeability) IS 4031(Part

More information

shall not exceed 8 not exceed 10.

shall not exceed 8 not exceed 10. Table 3602/1 CRUSHED STONE BASE AND SUBBASE: MATERIAL REQUIREMENTS Material TYPE OF MATERIAL Characteristic G1 G2 G3 Parent Sound rock from an approved Sound rock, boulders Sound rock, boulders or Material

More information

Risk Management of Rail Vehicle Axle Bearings

Risk Management of Rail Vehicle Axle Bearings Railway Group Standard Risk Management of Rail Vehicle Axle Bearings Synopsis This Railway Group Standard mandates that there shall be riskbased processes to minimise and detect failures of rail vehicle

More information

Microgeneration Installation Standard: MCS

Microgeneration Installation Standard: MCS Microgeneration Installation Standard: MCS 001-01 MCS Contractor Certification Scheme Requirements Part 1: Requirements for MCS Contractors Issue 3.1 This Microgeneration Installation Standard is the property

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK The Old School Stillhouse Lane Bedminster BS3 4EB Contact: Dr Dimitris Xirouchakis Tel: +44 (0)117-9471000 Fax: +44 (0)117-9471004 E-Mail:

More information

METHOD OF TEST FOR ABRASION OF COARSE AGGREGATE BY USE OF THE LOS ANGELES ABRASION TESTING MACHINE

METHOD OF TEST FOR ABRASION OF COARSE AGGREGATE BY USE OF THE LOS ANGELES ABRASION TESTING MACHINE STATE OF CALIFORNIA BUSINESS, TRANSPORTATION AND HOUSING AGENCY DEPARTMENT OF TRANSPORTATION DIVISION OF ENGINEERING SERVICES Transportation Laboratory 5900 Folsom Blvd. Sacramento, California 95819-4612

More information

AS/NZS 3112:2004 AS/NZS

AS/NZS 3112:2004 AS/NZS AS/NZS 3112:2011 Incorporating Amendment No. 1, 2, and 3 Australian/New Zealand Standard Approval and test specification Plugs and socket-outlets Superseding AS/NZS 3112:2004 AS/NZS 3112:2011 AS/NZS 3112:2011

More information

IGS-M-CH-051-1(0) Jan مصوب. Approved IGS. Molecular Sieve, Type 3A

IGS-M-CH-051-1(0) Jan مصوب. Approved IGS. Molecular Sieve, Type 3A IGS-M-CH-051-1(0) Jan. 2013 Approved مصوب شرآت ملي گازايران امورتدوين استانداردها IGS مشخصات فني براي خريد مولكولارسيو نوع 3A Molecular Sieve, Type 3A براي استفاده ازاستانداردها فقط به ا خرين نسخه منتشرشده

More information

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR PAVEMENT RIDE QUALITY (IRI ACCEPTANCE CRITERIA)

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR PAVEMENT RIDE QUALITY (IRI ACCEPTANCE CRITERIA) MICHIGAN DEPARTMENT OF TRANSPORTATION 03SP502(P) SPECIAL PROVISION FOR PAVEMENT RIDE QUALITY (IRI ACCEPTANCE CRITERIA) C&T:TEH 1 of 8 C&T:APPR:JFS:MJE:01-28-08 FHWA:APPR:02-01-08 a. Description. Provide

More information

68-253/Issue 1 (DERD 2491) 1 August 1997

68-253/Issue 1 (DERD 2491) 1 August 1997 Ministry of Defence Defence Standard 68-25/Issue 1 (DERD 2491) 1 August 1997 FLUIDS, AVIATION, THRUST AUGMENTATION JOINT SERVICE DESIGNATION: AL-28 AND WTA This Defence Standard supersedes DERD 2491 Issue

More information

SHELL NATURELLE CHANGEOVER ADVICE

SHELL NATURELLE CHANGEOVER ADVICE SHELL NATURELLE CHANGEOVER ADVICE Bulletin, 1 January 2018 This bulletin is issued to all customer vessels and shore-based staff to help manage and plan the conversion to the Shell Naturelle range of lubricants.

More information

Compatibility Between Electric Trains and Electrification Systems

Compatibility Between Electric Trains and Electrification Systems Compatibility Between Electric Trains and Electrification Systems Synopsis Process for managing change that affects the compatibility between electric trains and electrification systems Submitted by Signatures

More information

Controlling the Speed of Tilting Trains Through Curves

Controlling the Speed of Tilting Trains Through Curves Controlling the Speed of Tilting Trains Through Curves Synopsis This document mandates the means by which Tilting Trains may be operated at higher speeds than nontilting trains around curves. Signatures

More information

MATERIAL SPECIFICATION FOR ORGANIC SOLVENT BASED TRAFFIC PAINT

MATERIAL SPECIFICATION FOR ORGANIC SOLVENT BASED TRAFFIC PAINT ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 1712 FEBRUARY 1991 MATERIAL SPECIFICATION FOR ORGANIC SOLVENT BASED TRAFFIC PAINT 1712.01 SCOPE 1712.02 REFERENCES 1712.03 DEFINITIONS 1712.05 MATERIALS

More information

DESIGN PRACTICE NOTE MOBILITY VEHICLE SIMULATIONS AT PEDESTRIAN CROSSINGS

DESIGN PRACTICE NOTE MOBILITY VEHICLE SIMULATIONS AT PEDESTRIAN CROSSINGS Approval Amendment Record Approval Date Version Description 21/05/2015 1 Initial issue under MTM 04/08/2016 2 Clearance for mobility vehicles amended and details for fencing and paving added PRINTOUT MAY

More information

Implementation procedure for certification and continued airworthiness of Beriev Be-200E and Be-200ES-E

Implementation procedure for certification and continued airworthiness of Beriev Be-200E and Be-200ES-E 1. Scope 1.1 The general process is described in the implementation procedure for design approvals of aircraft, engine and propeller from CIS and in the implementation procedure for design approvals of

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 3131 Australian/New Zealand Standard Approval and test specification Plugs and socket-outlets for stationary appliances This Joint Australian/New Zealand Standard was prepared by Joint Technical

More information

Laboratory Certification For. Shakib Dastaggir Construction & Design Company (S-CAD) Laboratory

Laboratory Certification For. Shakib Dastaggir Construction & Design Company (S-CAD) Laboratory Laboratory Certification For Shakib Dastaggir Construction & Design Company (S-CAD) Laboratory Lab ID: LCP-006 Issue date: Sept 19, 2016 Expiry date: March 18, 2017 This letter confirms the completion

More information

OKLAHOMA DEPARTMENT OF TRANSPORTATION SPECIAL PROVISIONS FOR BITUMINOUS SURFACE TREATMENT

OKLAHOMA DEPARTMENT OF TRANSPORTATION SPECIAL PROVISIONS FOR BITUMINOUS SURFACE TREATMENT 402-1(a-e) 99 OKLAHOMA DEPARTMENT OF TRANSPORTATION SPECIAL PROVISIONS FOR BITUMINOUS SURFACE TREATMENT These Special Provisions revise, amend, and where in conflict, supersede applicable sections of the

More information

AS/NZS :2016. Grid connection of energy systems via inverters AS/NZS :2016. Part 1: Installation requirements

AS/NZS :2016. Grid connection of energy systems via inverters AS/NZS :2016. Part 1: Installation requirements AS/NZS 4777.1:2016 Australian/New Zealand Standard Grid connection of energy systems via inverters Part 1: Installation requirements AS/NZS 4777.1:2016 AS/NZS 4777.1:2016 This joint Australian/New Zealand

More information

IMO fuel oil consumption data collection system

IMO fuel oil consumption data collection system No. Subject: IMO fuel oil consumption data collection system IMO fuel oil consumption data collection system A similar scheme to EU MRV has also been adopted by IMO; according to Regulation 22A of MARPOL

More information

DMS-9202 Asphaltic Concrete Patching Material (Stockpile Storage or Bagged)

DMS-9202 Asphaltic Concrete Patching Material (Stockpile Storage or Bagged) Asphaltic Concrete Patching Material (Stockpile Storage or Bagged) Effective Date: May 2017 1. DESCRIPTION This Specification governs for crushed stone asphaltic concrete intended primarily as a cool-

More information

ANNEX 3. RESOLUTION MEPC.278(70) (Adopted on 28 October 2016)

ANNEX 3. RESOLUTION MEPC.278(70) (Adopted on 28 October 2016) Annex 3, page 1 ANNEX 3 RESOLUTION MEPC.278(70) (Adopted on 28 October 2016) AMENDMENTS TO THE ANNEX OF THE PROTOCOL OF 1997 TO AMEND THE INTERNATIONAL CONVENTION FOR THE PREVENTION OF POLLUTION FROM SHIPS,

More information

AGREEMENT. (Revision 2, including the amendments entered into force on 16 October 1995) Addendum 102: Regulation No. 103

AGREEMENT. (Revision 2, including the amendments entered into force on 16 October 1995) Addendum 102: Regulation No. 103 21 March 1997 AGREEMENT CONCERNING THE ADOPTION OF UNIFORM TECHNICAL PRESCRIPTIONS FOR WHEELED VEHICLES, EQUIPMENT AND PARTS WHICH CAN BE FITTED AND/OR BE USED ON WHEELED VEHICLES AND THE CONDITIONS FOR

More information

PETROLEUM PRODUCTS INSPECTION OPERATIONS MANUAL

PETROLEUM PRODUCTS INSPECTION OPERATIONS MANUAL Kenya Bureau of Standards PETROLEUM PRODUCTS INSPECTION OPERATIONS MANUAL 2016-01-14 Version 2.0 Page 1 1.0 INTRODUCTION 1.1 Purpose and Background This manual provides a frame work for inspection of petroleum

More information

ESF on Fire Protection Proposed ESF on Fire Protection Engine attachment points applicable to Piston Engines EASA

ESF on Fire Protection Proposed ESF on Fire Protection Engine attachment points applicable to Piston Engines EASA ESF on Fire Protection Proposed ESF on Fire Protection Engine attachment points applicable to Piston Engines EASA UK CAA Comment: Paragraph (2) of the ESF should clarify whether the other features of the

More information

PN /21/ SURFACE SMOOTHNESS REQUIREMENTS FOR PAVEMENTS

PN /21/ SURFACE SMOOTHNESS REQUIREMENTS FOR PAVEMENTS PN 420-10/21/2016 - SURFACE SMOOTHNESS REQUIREMENTS FOR PAVEMENTS DESCRIPTION: The surface tolerance specification requirements are modified as follows for all pavements of constant width with at least

More information

POLLUTION PREVENTION AND RESPONSE (MATTERS EMANATING FROM THE FIFTH SESSION OF THE SUB-COMMITTEE)

POLLUTION PREVENTION AND RESPONSE (MATTERS EMANATING FROM THE FIFTH SESSION OF THE SUB-COMMITTEE) E MARITIME SAFETY COMMITTEE 100th session Agenda item 8 MSC 100/8/1 XX October 2018 Original: ENGLISH POLLUTION PREVENTION AND RESPONSE (MATTERS EMANATING FROM THE FIFTH SESSION OF THE SUB-COMMITTEE) Effective

More information

E/ECE/324/Rev.2/Add.108/Rev.1/Amend.3 E/ECE/TRANS/505/Rev.2/Add.108/Rev.1/Amend.3

E/ECE/324/Rev.2/Add.108/Rev.1/Amend.3 E/ECE/TRANS/505/Rev.2/Add.108/Rev.1/Amend.3 16 January 2019 Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles, Equipment and Parts which can be Fitted and/or be Used on Wheeled Vehicles and

More information

Doc:TED 11(794)W 1 September 2012 Draft Standard Automotive Vehicles - Windscreen Wiping System for 3 Wheeler Vehicles - Specification

Doc:TED 11(794)W 1 September 2012 Draft Standard Automotive Vehicles - Windscreen Wiping System for 3 Wheeler Vehicles - Specification For Comments only Doc:TED 11(794)W 1 September 2012 Draft Standard Automotive Vehicles - Windscreen Wiping System for 3 Wheeler Vehicles - Specification Not to be reproduced without permission Last date

More information

NETWORK. Annex AC. Aurizon Network Ballast Fouling, 4 March 2013

NETWORK. Annex AC. Aurizon Network Ballast Fouling, 4 March 2013 NETWORK Annex AC 4 March 2013 Aurizon Network Ballast Fouling, Overview of the problem Ballast is the material that is laid on the rail bed under the sleepers, providing stability and drainage to the track

More information

PFI Quality Assurance/Quality Control (QA/QC) Program for Residential/Commercial Densified Fuels

PFI Quality Assurance/Quality Control (QA/QC) Program for Residential/Commercial Densified Fuels PFI Quality Assurance/Quality Control (QA/QC) Program for Residential/Commercial Densified Fuels Scope: This program must be utilized by participating pellet fuel manufacturers to assure consistent quality

More information

EU TOY DIRECTIVE 2009/48/EC: OVERVIEW - REGULATORY CONTEXT AND MAJOR CHANGES

EU TOY DIRECTIVE 2009/48/EC: OVERVIEW - REGULATORY CONTEXT AND MAJOR CHANGES EU TOY DIRECTIVE 2009/48/EC: OVERVIEW - REGULATORY CONTEXT AND MAJOR The EU Toy Directive was revised in order to take into account the new technological developments and increasing child safety requirements.

More information

Shoulder Ballast Cleaning Effectiveness

Shoulder Ballast Cleaning Effectiveness Shoulder Ballast Cleaning Effectiveness Word count: 3539 ABSTRACT AREMA 2015 Annual Conference 4 October 7 October 2015 Minneapolis, MN Scott Diercks Loram Maintenance of Way, Inc. 3900 Arrowhead Drive

More information

Track Circuit Assister Configuration for Rail Vehicles

Track Circuit Assister Configuration for Rail Vehicles Track Circuit Assister Configuration for Rail Synopsis This Standard mandates where TCAs shall be fitted onto a vehicle and how they shall be set up. It also contains the requirements for testing a TCA.

More information

NPS/003/019 Technical Specification for Electrical Insulating Fluids for use in Plant & Switchgear.

NPS/003/019 Technical Specification for Electrical Insulating Fluids for use in Plant & Switchgear. Version:- 5.2 Date of Issue:- Apr 2011 Page 1 of 11 NPS/003/019 Technical Specification for Electrical Insulating Fluids for use in Plant & Switchgear. 1. Purpose This specification details the technical

More information

Testing of Baier Plasterboard to AS/NZS (Electronic copy (PDF format) original signed by author) Materials Scientist.

Testing of Baier Plasterboard to AS/NZS (Electronic copy (PDF format) original signed by author) Materials Scientist. DC1333 Testing of aier Plasterboard to AS/NZS 2588 (Electronic copy (PDF format) original signed by author) Author: Neil Lee Materials Scientist Reviewer: ryan Keen Senior Technician Contact: RANZ Limited

More information

World Jaw TEREX JAQUES WORLD JAWS

World Jaw TEREX JAQUES WORLD JAWS World Jaw TEREX JAQUES WORLD JAWS High production Aggressive crushing action High strength design Full hydraulic setting adjustment Complete range of jaw profiles World Jaw We have been manufacturing jaw

More information

NOTICE TO SUPPLIERS CITY OF KALAMA 2018 CHEMICAL PROCUREMENT

NOTICE TO SUPPLIERS CITY OF KALAMA 2018 CHEMICAL PROCUREMENT NOTICE TO SUPPLIERS CITY OF KALAMA 2018 CHEMICAL PROCUREMENT Sealed proposals will be received by the undersigned at the City of Kalama, 195 N. First Street, PO Box 1007, Kalama, Washington 98625, up to

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Schedule of ccreditation United Kingdom ccreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK ccredited to Bootham Lane Industrial Estate Bootham Lane Dunscroft Doncaster

More information

Equipotential Bonding of Rail Vehicles to Running Rail Potential

Equipotential Bonding of Rail Vehicles to Running Rail Potential Railway Group Standard Equipotential Bonding of Rail Vehicles to Running Rail Potential Synopsis This standard mandates the requirements for equipotenial bonding of rail vehicles to comply with the Electricity

More information

Regulatory update on implementation of the 0.50% sulphur limit for international shipping

Regulatory update on implementation of the 0.50% sulphur limit for international shipping Regulatory update on implementation of the 0.50% sulphur limit for international shipping Marshall Islands Quality Council (MIQC), 19 April 2018 Trinity House, London Dr Edmund Hughes Marine Environment

More information

NPS/001/017 Technical Specification for Low Voltage and High Voltage Current Limiting Fuse Links

NPS/001/017 Technical Specification for Low Voltage and High Voltage Current Limiting Fuse Links Version:- 7.0 Date of Issue:- July 2017 Page 1 of 19 NPS/001/017 Technical Specification for Low Voltage and High Voltage Current Limiting Fuse Links 1. Purpose The purpose of this document is to detail

More information

MM-L-751H August 13, 1970 SUPERSEDING Int. Fed. Spec. MM-L-00751G(Army-ME) July 3, 1967 and Fed. Spec. MM-L-751C May 20, 1942 FEDERAL SPECIFICATION

MM-L-751H August 13, 1970 SUPERSEDING Int. Fed. Spec. MM-L-00751G(Army-ME) July 3, 1967 and Fed. Spec. MM-L-751C May 20, 1942 FEDERAL SPECIFICATION MM-L-751H August 13, 1970 SUPERSEDING Int. Fed. Spec. MM-L-00751G(Army-ME) July 3, 1967 and Fed. Spec. MM-L-751C May 20, 1942 FEDERAL SPECIFICATION LUMBER; SOFTWOOD This specification was approved by the

More information

08-Dec-10. VCA job number: CSL Date: 08 December Dear Sirs,

08-Dec-10. VCA job number: CSL Date: 08 December Dear Sirs, VCA job number: CSL225489 Date: 08 December 2010 Dear Sirs, 1. The vehicle type / component described on the attached approval(s) has been tested and meets the requirements of the ECE Regulation / EEC

More information

CHAPTER 25. SUBSTANTIVE RULES APPLICABLE TO ELECTRIC SERVICE PROVIDERS.

CHAPTER 25. SUBSTANTIVE RULES APPLICABLE TO ELECTRIC SERVICE PROVIDERS. 25.211. Interconnection of On-Site Distributed Generation (DG). (a) (b) (c) Application. Unless the context indicates otherwise, this section and 25.212 of this title (relating to Technical Requirements

More information

Branding of Wheels,Tyres and Axles

Branding of Wheels,Tyres and Axles Branding of Wheels,Tyres and Axles Signatures removed from electronic version Submitted by G A Clayton Nominated Responsible Manager Synopsis This standard details the branding requirements for all wheels,

More information

Shoulder Ballast Cleaning Effectiveness

Shoulder Ballast Cleaning Effectiveness Shoulder Ballast Cleaning Effectiveness AREMA 2015 Annual Conference 4 October 7 October 2015 Minneapolis, MN Scott Diercks Loram Maintenance of Way, Inc. 3900 Arrowhead Drive Hamel, MN 55340 763-478-2622

More information

Volume 1 Series 2200 Specification for Road Works. Clause Title Page

Volume 1 Series 2200 Specification for Road Works. Clause Title Page PARAPETS Contents Clause Title Page 2201 General... 2 2202 Vehicle... 2 2203 Anchorages and Attachment Systems for Vehicle... 2 2204 Amendments and Additions to BS 6779... 3 2205 Protection Against Corrosion...

More information

JW SERIES WORLD JAW. Terex Minerals Processing Systems

JW SERIES WORLD JAW. Terex Minerals Processing Systems JW SERIES WORLD JAW Terex Minerals Processing Systems DESIGNED TO DELIVER Terex JW World Jaw We have been manufacturing jaw crushers for 120 years and over this period have gained a reputation for producing

More information

Terex Minerals Processing Systems JW SERIES JAW CRUSHERS

Terex Minerals Processing Systems JW SERIES JAW CRUSHERS Terex Minerals Processing Systems JW SERIES JAW CRUSHERS DESIGNED TO DELIVER Terex JW Series We have been manufacturing jaw crushers for 120 years and over this period have gained a reputation for producing

More information

AGREEMENT. done at Vienna on 13 November Addendum 1: Rule No. 1. Revision 1

AGREEMENT. done at Vienna on 13 November Addendum 1: Rule No. 1. Revision 1 6 March 2007 AGREEMENT CONCERNING THE ADOPTION OF UNIFORM CONDITIONS FOR PERIODICAL TECHNICAL INSPECTIONS OF WHEELED VEHICLES AND THE RECIPROCAL RECOGNITION OF SUCH INSPECTIONS done at Vienna on 13 November

More information

Permissible Track Forces for Railway Vehicles

Permissible Track Forces for Railway Vehicles British Railways Board Page 1 of 11 Part A Synopsis This document prescribes design and maintenance requirements for traction and rolling stock and for on track plant to ensure that interactive forces

More information

DESCRIPTION This work consists of measuring the smoothness of the final concrete or bituminous surface.

DESCRIPTION This work consists of measuring the smoothness of the final concrete or bituminous surface. 2399 PAVEMENT SURFACE SMOOTHNESS 2399.1 DESCRIPTION This work consists of measuring the smoothness of the final concrete or bituminous surface. A Definitions The Department defines Smoothness as the Mean

More information

Ballast Water Management Convention to Enter Into Force 8th September 2017 Guidance

Ballast Water Management Convention to Enter Into Force 8th September 2017 Guidance Ballast Water Management Convention to Enter Into Force 8th September 2017 Guidance 1 Contents Introduction... 3 Scope of Application... 3 Flag State Application... 3 IOPP... 4 BWM system approval... 4

More information

ECOMP.3.A EUROPEAN UNION. Brussels, 12 December 2018 (OR. en) 2018/0220 (COD) PE-CONS 67/18 ENT 229 MI 914 ENV 837 AGRI 596 PREP-BXT 58 CODEC 2164

ECOMP.3.A EUROPEAN UNION. Brussels, 12 December 2018 (OR. en) 2018/0220 (COD) PE-CONS 67/18 ENT 229 MI 914 ENV 837 AGRI 596 PREP-BXT 58 CODEC 2164 EUROPEAN UNION THE EUROPEAN PARLIAMT THE COUNCIL Brussels, 12 December 2018 (OR. en) 2018/0220 (COD) PE-CONS 67/18 T 229 MI 914 V 837 AGRI 596 PREP-BXT 58 CODEC 2164 LEGISLATIVE ACTS AND OTHER INSTRUMTS

More information

CLASSIFICATION NOTES. Type Testing Procedure for. Crankcase Explosion Relief Valves

CLASSIFICATION NOTES. Type Testing Procedure for. Crankcase Explosion Relief Valves CLASSIFICATION NOTES Type Testing Procedure for Crankcase Explosion Relief Valves Contents 1. Scope, Application 2. Recognized Standards 3. Purpose 4. Test Facilities 5. Explosion Test Process 6. Testing

More information

Form of IOPP Certificate and Supplements * INTERNATIONAL OIL POLLUTION PREVENTION CERTIFICATE

Form of IOPP Certificate and Supplements * INTERNATIONAL OIL POLLUTION PREVENTION CERTIFICATE Appendix II Appendices to Annex I Form of IOPP Certificate and Supplements * Annex I INTERNATIONAL OIL POLLUTION PREVENTION CERTIFICATE (Note: This Certificate shall be supplemented by a Record of Construction

More information

10-Feb-14. VCA job number: CSP Date: 10 February Dear Sirs,

10-Feb-14. VCA job number: CSP Date: 10 February Dear Sirs, VCA job number: CSP286498 Date: 10 February 2014 Dear Sirs, 1. The vehicle type / component described on the attached approval(s) has been tested and meets the requirements of the ECE Regulation / EEC

More information

TABLE OF CONTENTS FOREWORD... 2 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 3

TABLE OF CONTENTS FOREWORD... 2 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 3 TITLE SPECIFICATION FOR MEDIUM VOLTAGE DATE: FEBRUARY 2015 PAGE: 1 OF 25 TABLE OF CONTENTS Page FOREWORD... 2 INTRODUCTION... 3 1 SCOPE... 3 2 NORMATIVE S... 3 3 DEFINITIONS AND ABBIATIONS... 3 4 REQUIREMENTS...

More information

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) 020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service

More information

30-Aug-11. VCA job number: CSM Date: 30 August Dear Sirs,

30-Aug-11. VCA job number: CSM Date: 30 August Dear Sirs, VCA job number: CSM241075 Date: 30 August 2011 Dear Sirs, 1. The vehicle type / component described on the attached approval(s) has been tested and meets the requirements of the ECE Regulation / EEC Directive

More information

Assisted School Travel Program. Eligible Service Provider Request for Increased Run Capacity

Assisted School Travel Program. Eligible Service Provider Request for Increased Run Capacity Version 1.0 Assisted School Travel Program Eligible Service Provider Request for Increased Run Capacity Eligible Service Providers to the Department of Education and Communities Assisted School Travel

More information

Purchasing Services 4202 East Fowler Avenue, SVC 1073 Tampa, Florida (813) Addendum No. 1

Purchasing Services 4202 East Fowler Avenue, SVC 1073 Tampa, Florida (813) Addendum No. 1 Purchasing Services 4202 East Fowler Avenue, SVC 1073 Tampa, Florida 33620 (813) 974-2481 Invitation to Bid No.: 18-12-YH Entitled: Opening Date: Bulk Fuel Delivery (PATS) November 14, 2017 at 3:00 p.m.

More information

Learning Legacy Document

Learning Legacy Document SUSTAINABILITY & CONSENTS Guidance on Diesel Engine Emissions from Non-Road Mobile Machinery (NRMM) and retrofitting with Diesel Particulate Filters (DPF) Document History: Document Number: CR-XRL-T1-GUI-CR001-50005

More information

Guidance for Low Voltage Electrical Installations

Guidance for Low Voltage Electrical Installations Guidance for Low Voltage Electrical Synopsis This document provides information in support of GI/RT7007 Low Voltage Electrical. Signatures removed from electronic version Submitted by Anne E Blakeney Standards

More information

INCOMING INSPECTION DELEGATION GUIDELINES FOR ALENIA SUPPLIERS PROGRAM: ALL

INCOMING INSPECTION DELEGATION GUIDELINES FOR ALENIA SUPPLIERS PROGRAM: ALL INCOMING INSPECTION DELEGATION GUIDELINES FOR ALENIA SUPPLIERS PROGRAM: ALL THE CONTENT OF THIS DOCUMENT IS THE PROPERTY OF ALENIA AERONAUTICA S.p.A. THIS DOCUMENT IS SUPPLIED IN CONFIDENCE AND COMMERCIAL

More information

Terex Minerals Processing Systems JW SERIES JAW CRUSHERS

Terex Minerals Processing Systems JW SERIES JAW CRUSHERS Terex Minerals Processing Systems JW SERIES JAW CRUSHERS DESIGNED TO DELIVER Terex JW Series We have been manufacturing jaw crushers for over 120 years and have gained a well-known reputation for producing

More information

Consistent implementation of the 2020 sulphur limit and work to further address GHG emissions from international shipping

Consistent implementation of the 2020 sulphur limit and work to further address GHG emissions from international shipping Consistent implementation of the 2020 sulphur limit and work to further address GHG emissions from international shipping IBIA/BMS United A glimpse into the future of shipping 30 May 2018, Athens, Greece

More information

Mattest (Ireland) Ltd

Mattest (Ireland) Ltd Unit 18 University Hall, Sarsfield Road, Wilton, Cork Registration number: 289T is accredited by the Irish National Board (INAB) to undertake testing as detailed in the Schedule bearing the Registration

More information

ST. VINCENT AND THE GRENADINES

ST. VINCENT AND THE GRENADINES ST. VINCENT AND THE GRENADINES MARITIME ADMINISTRATION CIRCULAR N POL 022 FUEL OIL CONSUMPTION DATA COLLECTION SYSTEM Amendments to MARPOL Annex VI, MEPC.278(70) TO: APPLICABLE TO: EFFECTIVE AS FROM: SHIPOWNERS,

More information

PTV TECHNICAL PRESCRIPTIONS. ELASTOMERIC SEALS: Part 1: Vulcanized Rubber FOR. Impartial institute for the monitoring of construction products

PTV TECHNICAL PRESCRIPTIONS. ELASTOMERIC SEALS: Part 1: Vulcanized Rubber FOR. Impartial institute for the monitoring of construction products PTV 8681-1 TECHNICAL PRESCRIPTIONS TECHNICAL PRESCRIPTIONS FOR ELASTOMERIC SEALS: Part 1: Vulcanized Rubber COPRO vzw Version 1.0 dated 2017-10-17 Impartial institute for the monitoring of construction

More information

Mechanical Trainstop Systems

Mechanical Trainstop Systems Mechanical Trainstop Systems Synopsis This document defines the functional requirements for mechanical trainstop systems and the requirements relating to their use on both track and trains. Signatures

More information

Appendix Item Addendum

Appendix Item Addendum Addendum to ESAH Version 3 Supply Application Appendix Item Addendum 1 Electrical System Item 1.4.5 Short Circuit Ratings Addendum for type of short circuit rating for system voltage of 275kV. 2 Types

More information

Doc:TED 11(794)W Dec Draft Standard Automotive Vehicles - Windscreen Wiping System for 3 Wheeler Vehicles - Specification

Doc:TED 11(794)W Dec Draft Standard Automotive Vehicles - Windscreen Wiping System for 3 Wheeler Vehicles - Specification For Comments only Doc:TED 11(794)W Dec 2010 Draft Standard Automotive Vehicles - Windscreen Wiping System for 3 Wheeler Vehicles - Specification Not to be reproduced without permission Last date for receipt

More information

THE UNITED KINGDOM TYPE APPROVAL AUTHORITY

THE UNITED KINGDOM TYPE APPROVAL AUTHORITY THE UNITED KINGDOM TYPE APPROVAL AUTHORITY Dear Sir / Madam. Date: 19 January 2015 1. The vehicle component / type described on the attached approval(s) has been tested and meets the requirements of the

More information

General Specifications

General Specifications General Specifications Bid # 2372 Fire Hydrants Water Resource Department The contract period for these items is for 1 full year beginning the effective date of the awarded contract, December 1, 2012 to

More information

PROCEDURE. Operative Date: 22/12/2016 Department: HSEC. Revision: Author: D Steel CONTENTS

PROCEDURE. Operative Date: 22/12/2016 Department: HSEC. Revision: Author: D Steel CONTENTS Title: Cranes - Inspection and Maintenance PROCEDURE Procedure No: P314.422 Issue: 1 Revision: 0 Operative Date: 22/12/2016 Department: HSEC Sect./Classification: Safety / Gear & Equipment Author: D Steel

More information

11-Feb-14. VCA job number: CSP Date: 11 February Dear Sirs,

11-Feb-14. VCA job number: CSP Date: 11 February Dear Sirs, VCA job number: CSP286503 Date: 11 February 2014 Dear Sirs, 1. The vehicle type / component described on the attached approval(s) has been tested and meets the requirements of the ECE Regulation / EEC

More information

Ballast Water Management Surveyor Guidance An outline of Maritime NZ requirements of Surveyors for the purposes of Ballast Water Management

Ballast Water Management Surveyor Guidance An outline of Maritime NZ requirements of Surveyors for the purposes of Ballast Water Management Ballast Water Management Surveyor Guidance An outline of Maritime NZ requirements of Surveyors for the purposes of Ballast Water Management Ballast water management surveyor guidance Page 1 of 9 Ballast

More information

Practice Note on the Sourcing of Threaded Rod Used for Foundation Bolts

Practice Note on the Sourcing of Threaded Rod Used for Foundation Bolts MATERIALS Practice Note on the Sourcing of Threaded Rod Used for Foundation Bolts Authors: Kevin Cowie, Alistair Fussell Affiliation: Steel Construction New Zealand Inc. Date: 20 th February 2018 Ref.:

More information

E/ECE/324/Rev.2/Add.115/Amend.3 E/ECE/TRANS/505/Rev.2/Add.115/Amend.3

E/ECE/324/Rev.2/Add.115/Amend.3 E/ECE/TRANS/505/Rev.2/Add.115/Amend.3 7 July 2011 Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles, Equipment and Parts which can be Fitted and/or be Used on Wheeled Vehicles and the Conditions for

More information

Microgeneration Installation Standard: MCS 023

Microgeneration Installation Standard: MCS 023 Microgeneration Installation Standard: MCS 023 Additional Requirements for MCS Contractors to demonstrate PAS2030 equivalence for the installation of Microgeneration technologies. Issue 2.1 This Microgeneration

More information

E/ECE/324/Rev.1/Add.38/Rev.2 E/ECE/TRANS/505/Rev.1/Add.38/Rev.2

E/ECE/324/Rev.1/Add.38/Rev.2 E/ECE/TRANS/505/Rev.1/Add.38/Rev.2 E/ECE/324/Rev.1/Add.38/Rev.2 24 January 2018 Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles, Equipment and Parts which can be Fitted and/or be

More information

CITY AND COUNTY OF SAN FRANCISCO. SPECIFICATION FOR Copier Lease Agreement Last revision 03/03/2016

CITY AND COUNTY OF SAN FRANCISCO. SPECIFICATION FOR Copier Lease Agreement Last revision 03/03/2016 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 SECTION 1 GENERAL EQUIPMENT SPECIFICATIONS: SPECIFICATION OUTLINE: SFMTA is

More information

SAFER ROADS FOR TASMANIA GUNN S HILL PROJECT SKID RESISTANCE FIELD ASSESSMENT

SAFER ROADS FOR TASMANIA GUNN S HILL PROJECT SKID RESISTANCE FIELD ASSESSMENT SAFER ROADS FOR TASMANIA GUNN S HILL PROJECT SKID RESISTANCE FIELD ASSESSMENT Authors: Ion Dumitru, Vasile Caprar, Wally Komsta Boral Construction Materials and Phil Sidney Roadways Pty. Ltd. ABSTRACT:

More information