Customer Product Manual Part E02
|
|
- Dominic Quentin Baldwin
- 5 years ago
- Views:
Transcription
1 e.dot Gun Customer Product Manual Issued 9/06 NORDSON CORPORATION DULUTH, GEORGIA USA
2 For CE Declaration, refer to melter manual. Nordson Corporation welcomes requests for information, comments, and inquiries about its products. General information about Nordson can be found on the Internet using the following address: Address all correspondence to: Nordson Corporation Attn: Customer Service Lakefield Drive Duluth, GA Notice This is a Nordson Corporation publication which is protected by copyright. Original copyright date No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Nordson Corporation. The information contained in this publication is subject to change without notice. Trademarks AccuJet, AeroCharge, Apogee, AquaGuard, Asymtek, Automove, Baitgun, Blue Box, CanWorks, Century, CF, Clean Coat, CleanSleeve, CleanSpray, ColorMax, Control Coat, Coolwave, Cross-Cut, Cyclo-Kinetic, Dispensejet, DispenseMate, DuraBlue, Durafiber, Dura-Screen, Durasystem, Easy Coat, Easymove Plus, Ecodry, Econo-Coat, e.dot, EFD, e stylized, ETI, Excel 2000, Fillmaster, FlexiCoat, Flexi-Spray, Flex-O-Coat, Flow Sentry, Fluidmove, FoamMelt, FoamMix, Heli-flow, Helix, Horizon, Hot Shot, icontrol, iflow, Isocoil, Isocore, Iso-Flo, itrax, Kinetix, Little Squirt, LogiComm, Magnastatic, March, MEG, Meltex, Microcoat, Micromark, MicroSet, Millennium, Mini Squirt, Mountaingate, MultiScan, Nordson, OptiMix, Package of Values, Pattern View, PermaFlo, Plasmod, Porous Coat, PowderGrid, Powderware, Printplus, Prism, ProBlue, Pro-Flo, ProLink, Pro-Meter, Pro-Stream, RBX, Rhino, Saturn, Scoreguard, Seal Sentry, Select Charge, Select Coat, Select Cure, Slautterback, Smart-Coat, Solder Plus, Spectrum, Speed-Coat, SureBead, Sure Clean, Sure Coat, Sure-Max, TRAK, Tracking Plus, Trends, Tribomatic, Ultra, Ultrasaver, UpTime, Vantage, Veritec, VersaBlue, Versa-Coat, Versa-Screen, Versa-Spray, Walcom, Watermark, and When you expect more. are registered trademarks of Nordson Corporation. Accubar, Advanced Plasma Systems, AeroDeck, AeroWash, AltaBlue, AquaCure, ATS, Auto-Flo, AutoScan, Best Choice, Blue Series, Check Mate, Classicblue, Colo-on-Demand, Controlled Fiberization, Control Weave, CPX, DispensLink, Dry Cure, DuraBraid, DuraCoat, DuraDrum, DuraPail, Easy Clean, EasyOn, Eclipse, E-Nordson, Equi=Bead, ESP, Fill Sentry, G Net, G Site, HDLV, ion, Iso-Flex, itrend, Lacquer Cure, Lean Cell, Maverick, Maxima, MicroFin, MicroMax, MiniBlue, MiniEdge, Minimeter, Multifil, Myritex, OptiStroke, PatternPro, PCI, Powder Pilot, Powercure, Primarc, Process Sentry, Prodigy, Pulse Spray, Quad Cure, Ready Coat, Royal Blue, Select Series, Sensomatic, Shaftshield, SheetAire, Smart, SolidBlue, Spectral, Spectronic, SpeedKing, Spray Works, Summit, Sure Brand, SureMix, SureSeal, Sure Wrap, Swirl Coat, Tempus, ThruWave, Trade Plus, TrueBlue, Ultrasmart, Universal, VersaDrum, VersaPail, Vista, Web Cure, and 2 Rings (Design) are trademarks of Nordson Corporation. Designations and trademarks stated in this document may be brands that, when used by third parties for their own purposes, could lead to violation of the owners rights. Viton is a registered trademark of DuPont Dow Elastomers. L.L.C Nordson Corporation All rights reserved
3 Table of Contents i Table of Contents Safety Safety Alert Symbols Responsibilities of the Equipment Owner Safety Information Instructions, Requirements, and Standards User Qualifications Applicable Industry Safety Practices Intended Use of the Equipment Instructions and Safety Messages Installation Practices Operating Practices Maintenance and Repair Practices Equipment Safety Information Equipment Shutdown General Safety Warnings and Cautions Other Safety Precautions First Aid Safety Labels and Tags Description Intended Uses Unintended Uses Auxiliary Devices and Spare Parts Installation Installation Guidelines Mounting Hydraulic Connections Mounting the Gun Mounting the Gun Driver/Pattern Control Connecting the Hose Connecting Hose Cordsets Connecting an EPC-30 to the e driver2, 3, or 4 (Optional) Operation Melter Adjustment Driver Electrical Adjustment e driver and e driver2, 3, and LA Dot Size Adjustment e driver and e driver2, 3, and LA Pattern Control Adjustment EPC LA Stroke Adjustment Nordson Corporation
4 ii Table of Contents Troubleshooting Troubleshooting Table Maintenance Cleaning/Replacing the Nozzle and the Armature Rezeroing the Gun Changing the Filter Removing the Cordset Installing the Cordset Parts e.dot Gun Components Gun Service Kits Nozzles Filters e.dot Small Diameter Hoses e drivers e driver cables Technical Data Gun Specifications Gun Dimensions Gun Wiring Diagram Cable Wiring Diagrams Nordson Corporation
5 e.dot Gun 1 e.dot Gun Safety Read this section before using the equipment. This section contains recommendations and practices applicable to the safe installation, operation, and maintenance (hereafter referred to as use ) of the product described in this document (hereafter referred to as equipment ). Additional safety information, in the form of task-specific safety alert messages, appears as appropriate throughout this document. WARNING: Risk of Burns! Do not remove the nozzle when the system is pressurized. Removing the nozzle when the system is pressurized will cause hot melt to free-flow from the gun. Relieve system pressure before removing the nozzle. Failure to relieve system pressure can result in personal injury. WARNING: Failure to follow the safety messages, recommendations, and hazard avoidance procedures provided in this document can result in personal injury, including death, or damage to equipment or property. Safety Alert Symbols The following safety alert symbol and signal words are used throughout this document to alert the reader to personal safety hazards or to identify conditions that may result in damage to equipment or property. Comply with all safety information that follows the signal word. WARNING: Indicates a potentially hazardous situation that, if not avoided, can result in serious personal injury, including death. CAUTION: Indicates a potentially hazardous situation that, if not avoided, can result in minor or moderate personal injury. CAUTION: (Used without the safety alert symbol) Indicates a potentially hazardous situation that, if not avoided, can result in damage to equipment or property Nordson Corporation
6 2 e.dot Gun Responsibilities of the Equipment Owner Equipment owners are responsible for managing safety information, ensuring that all instructions and regulatory requirements for use of the equipment are met, and for qualifying all potential users. Safety Information Research and evaluate safety information from all applicable sources, including the owner-specific safety policy, best industry practices, governing regulations, material manufacturer s product information, and this document. Make safety information available to equipment users in accordance with governing regulations. Contact the authority having jurisdiction for information. Maintain safety information, including the safety labels affixed to the equipment, in readable condition. Instructions, Requirements, and Standards Ensure that the equipment is used in accordance with the information provided in this document, governing codes and regulations, and best industry practices. If applicable, receive approval from your facility s engineering or safety department, or other similar function within your organization, before installing or operating the equipment for the first time. Provide appropriate emergency and first aid equipment. Conduct safety inspections to ensure required practices are being followed. Re-evaluate safety practices and procedures whenever changes are made to the process or equipment Nordson Corporation
7 e.dot Gun 3 User Qualifications Equipment owners are responsible for ensuring that users: receive safety training appropriate to their job function as directed by governing regulations and best industry practices are familiar with the equipment owner s safety and accident prevention policies and procedures receive, equipment- and task-specific training from another qualified individual NOTE: Nordson can provide equipment-specific installation, operation, and maintenance training. Contact your Nordson representative for information possess industry- and trade-specific skills and a level of experience appropriate to their job function are physically capable of performing their job function and are not under the influence of any substance that degrades their mental capacity or physical capabilities Applicable Industry Safety Practices The following safety practices apply to the use of the equipment in the manner described in this document. The information provided here is not meant to include all possible safety practices, but represents the best safety practices for equipment of similar hazard potential used in similar industries. Intended Use of the Equipment Use the equipment only for the purposes described and within the limits specified in this document. Do not modify the equipment. Do not use incompatible materials or unapproved auxiliary devices. Contact your Nordson representative if you have any questions on material compatibility or the use of non-standard auxiliary devices Nordson Corporation
8 4 e.dot Gun Instructions and Safety Messages Read and follow the instructions provided in this document and other referenced documents. Familiarize yourself with the location and meaning of the safety warning labels and tags affixed to the equipment. Refer to Safety Labels and Tags at the end of this section. If you are unsure of how to use the equipment, contact your Nordson representative for assistance. Installation Practices Install the equipment in accordance with the instructions provided in this document and in the documentation provided with auxiliary devices. Ensure that the equipment is rated for the environment in which it will be used and that the processing characteristics of the material will not create a hazardous environment. Refer to the Material Safety Data Sheet (MSDS) for the material. If the required installation configuration does not match the installation instructions, contact your Nordson representative for assistance. Position the equipment for safe operation. Observe the requirements for clearance between the equipment and other objects. Install lockable power disconnects to isolate the equipment and all independently powered auxiliary devices from their power sources. Properly ground all equipment. Contact your local building code enforcement agency for specific requirements. Ensure that fuses of the correct type and rating are installed in fused equipment. Contact the authority having jurisdiction to determine the requirement for installation permits or inspections Nordson Corporation
9 e.dot Gun 5 Operating Practices Familiarize yourself with the location and operation of all safety devices and indicators. Confirm that the equipment, including all safety devices (guards, interlocks, etc.), is in good working order and that the required environmental conditions exist. Use the personal protective equipment (PPE) specified for each task. Refer to Equipment Safety Information or the material manufacturer s instructions and MSDS for PPE requirements. Do not use equipment that is malfunctioning or shows signs of a potential malfunction. Maintenance and Repair Practices Perform scheduled maintenance activities at the intervals described in this document. Relieve system hydraulic and pneumatic pressure before servicing the equipment. De-energize the equipment and all auxiliary devices before servicing the equipment. Use only new factory-authorized refurbished or replacement parts. Read and comply with the manufacturer s instructions and the MSDS supplied with equipment cleaning compounds. NOTE: MSDSs for cleaning compounds that are sold by Nordson are available at or by calling your Nordson representative. Confirm the correct operation of all safety devices before placing the equipment back into operation. Dispose of waste cleaning compounds and residual process materials according to governing regulations. Refer to the applicable MSDS or contact the authority having jurisdiction for information. Keep equipment safety warning labels clean. Replace worn or damaged labels Nordson Corporation
10 6 e.dot Gun Equipment Safety Information This equipment safety information is applicable to the following types of Nordson equipment: hot melt and cold adhesive application equipment and all related accessories pattern controllers, timers, detection and verification systems, and all other optional process control devices Equipment Shutdown To safely complete many of the procedures described in this document, the equipment must first be shut down. The level of shut down required varies by the type of equipment in use and the procedure being completed. If required, shut down instructions are specified at the start of the procedure. The levels of shut down are: Relieving System Hydraulic Pressure Completely relieve system hydraulic pressure before breaking any hydraulic connection or seal. Refer to the melter-specific product manual for instructions on relieving system hydraulic pressure. De-energizing the System Isolate the system (melter, hoses, guns, and optional devices) from all power sources before accessing any unprotected high-voltage wiring or connection point. 1. Turn off the equipment and all auxiliary devices connected to the equipment (system). 2. To prevent the equipment from being accidentally energized, lock and tag the disconnect switch(es) or circuit breaker(s) that provide input electrical power to the equipment and optional devices. NOTE: Government regulations and industry standards dictate specific requirements for the isolation of hazardous energy sources. Refer to the appropriate regulation or standard Nordson Corporation
11 e.dot Gun 7 Disabling the Guns All electrical or mechanical devices that provide an activation signal to the guns, gun solenoid valve(s), or the melter pump must be disabled before work can be performed on or around a gun that is connected to a pressurized system. 1. Turn off or disconnect the gun triggering device (pattern controller, timer, PLC, etc.). 2. Disconnect the input signal wiring to the gun solenoid valve(s). 3. Reduce the air pressure to the gun solenoid valve(s) to zero; then relieve the residual air pressure between the regulator and the gun. General Safety Warnings and Cautions Table 1 contains the general safety warnings and cautions that apply to Nordson hot melt and cold adhesive equipment. Review the table and carefully read all of the warnings or cautions that apply to the type of equipment described in this manual. Equipment types are designated in Table 1 as follows: HM = Hot melt (melters, hoses, guns, etc.) PC = Process control CA = Cold adhesive (dispensing pumps, pressurized container, and guns) 2006 Nordson Corporation
12 8 e.dot Gun General Safety Warnings and Cautions (contd) Equipment Type HM Table 1 General Safety Warnings and Cautions Warning or Caution WARNING: Hazardous vapors! Before processing any polyurethane reactive (PUR) hot melt or solvent-based material through a compatible Nordson melter, read and comply with the material s MSDS. Ensure that the material s processing temperature and flashpoints will not be exceeded and that all requirements for safe handling, ventilation, first aid, and personal protective equipment are met. Failure to comply with MSDS requirements can cause personal injury, including death. HM WARNING: Reactive material! Never clean any aluminum component or flush Nordson equipment with halogenated hydrocarbon fluids. Nordson melters and guns contain aluminum components that may react violently with halogenated hydrocarbons. The use of halogenated hydrocarbon compounds in Nordson equipment can cause personal injury, including death. HM, CA WARNING: System pressurized! Relieve system hydraulic pressure before breaking any hydraulic connection or seal. Failure to relieve the system hydraulic pressure can result in the uncontrolled release of hot melt or cold adhesive, causing personal injury. HM WARNING: Molten material! Wear eye or face protection, clothing that protects exposed skin, and heat-protective gloves when servicing equipment that contains molten hot melt. Even when solidified, hot melt can still cause burns. Failure to wear appropriate personal protective equipment can result in personal injury. HM, PC WARNING: Equipment starts automatically! Remote triggering devices are used to control automatic hot melt guns. Before working on or near an operating gun, disable the gun s triggering device and remove the air supply to the gun s solenoid valve(s). Failure to disable the gun s triggering device and remove the supply of air to the solenoid valve(s) can result in personal injury. HM, CA, PC WARNING: Risk of electrocution! Even when switched off and electrically isolated at the disconnect switch or circuit breaker, the equipment may still be connected to energized auxiliary devices. De-energize and electrically isolate all auxiliary devices before servicing the equipment. Failure to properly isolate electrical power to auxiliary equipment before servicing the equipment can result in personal injury, including death. Continued Nordson Corporation
13 e.dot Gun 9 Equipment Type HM, CA, PC Table 1 General Safety Warnings and Cautions (contd) Warning or Caution WARNING: Risk of fire or explosion! Nordson adhesive equipment is not rated for use in explosive environments and should not be used with solvent-based adhesives that can create an explosive atmosphere when processed. Refer to the MSDS for the adhesive to determine its processing characteristics and limitations. The use of incompatible solvent-based adhesives or the improper processing of solvent-based adhesives can result in personal injury, including death. HM, CA, PC WARNING: Allow only personnel with appropriate training and experience to operate or service the equipment. The use of untrained or inexperienced personnel to operate or service the equipment can result in injury, including death, to themselves and others and can damage to the equipment. HM CAUTION: Hot surfaces! Avoid contact with the hot metal surfaces of guns, hoses, and certain components of the melter. If contact can not be avoided, wear heat-protective gloves and clothing when working around heated equipment. Failure to avoid contact with hot metal surfaces can result in personal injury. HM CAUTION: Some Nordson melters are specifically designed to process polyurethane reactive (PUR) hot melt. Attempting to process PUR in equipment not specifically designed for this purpose can damage the equipment and cause premature reaction of the hot melt. If you are unsure of the equipment s ability to process PUR, contact your Nordson representative for assistance. HM, CA CAUTION: Before using any cleaning or flushing compound on or in the equipment, read and comply with the manufacturer s instructions and the MSDS supplied with the compound. Some cleaning compounds can react unpredictably with hot melt or cold adhesive, resulting in damage to the equipment. HM CAUTION: Nordson hot melt equipment is factory tested with Nordson Type R fluid that contains polyester adipate plasticizer. Certain hot melt materials can react with Type R fluid and form a solid gum that can clog the equipment. Before using the equipment, confirm that the hot melt is compatible with Type R fluid Nordson Corporation
14 10 e.dot Gun Other Safety Precautions Do not use an open flame to heat hot melt system components. Check high pressure hoses daily for signs of excessive wear, damage, or leaks. Never point a dispensing handgun at yourself or others. Suspend dispensing handguns by their proper suspension point. First Aid If molten hot melt comes in contact with your skin: 1. Do NOT attempt to remove the molten hot melt from your skin. 2. Immediately soak the affected area in clean, cold water until the hot melt has cooled. 3. Do NOT attempt to remove the solidified hot melt from your skin. 4. In case of severe burns, treat for shock. 5. Seek expert medical attention immediately. Give the MSDS for the hot melt to the medical personnel providing treatment Nordson Corporation
15 e.dot Gun 11 Safety Labels and Tags Figure 1 illustrates the location of the product safety labels and tags affixed to the equipment. Table 2 provides an illustration of the hazard identification symbols that appear on each safety label and tag, the meaning of the symbol, or the exact wording of any safety message. 1 2 Figure 1 Safety labels and tags Table 2 Safety Labels and Tags Item Part Description N/A WARNING: Hot surface! Before touching the gun body, allow the gun to 1 cool, or wear heat-protective gloves. Failure to allow the gun body to cool or to wear heat-protective gloves may cause personal injury WARNING: Disconnect power and remove system pressure before 2 disassembly or maintenance. Failure to follow these instructions may result in serious personal injury Nordson Corporation
16 12 e.dot Gun Description The e.dot gun is a compact, high-speed, precision hot melt adhesive gun that is designed for use in applications requiring small dots of adhesive. The e.dot gun is used with the following Nordson components to form an adhesive dot application system: Nordson small diameter e.dot hose e driver, e driver2, 3, 4 (2, 3, or 4 modules), or the LA4400 EPC-30 pattern control (optional) Interface cables that connect the driver/pattern control to the e.dot hose NOTE: The components listed above are ordered and shipped separately from the e.dot gun. Figure 1 illustrates the various combination of drivers/pattern controls (1), cabling (2), small diameter e.dot hot melt hoses (3), and e.dot gun configurations (4) that can be assembled to form a complete adhesive dot application system. Intended Uses Unintended Uses The e.dot gun is designed for use in industrial applications that require the deposition of a precise dot of hot melt adhesive onto a moving substate with small diameter hoses designed and manufactured by Nordson Corporation with electric gun drivers and pattern controllers designed and manufactured by Nordson Corporation The e.dot gun is not designed for industrial applications that require the deposition of a bead of hot melt adhesive onto a moving substate use in explosive environments 2006 Nordson Corporation
17 e.dot Gun 13 Auxiliary Devices and Spare Parts e.dot guns should only be connected to approved auxiliary devices. Use only new Nordson replacement parts or approved factory refurbished parts. Figure 1 e.dot gun system 2006 Nordson Corporation
18 14 e.dot Gun Installation Complete the following four steps to install an dot application system: 1. Mount the gun 2. Mount the driver/pattern control 3. Connect the hose 4. Connect cordsets Installation Guidelines Use the following installation guidelines to achieve optimal gun performance. Nozzle clearance 3 6 mm ( in.) Mounting Mount the gun so that the nozzle will be 3 6 mm ( 1 / 8 1 / 4 in.) from the substrate. Use a 9.5 mm ( 3 / 8 in.) mounting bar. Allow for sufficient room to remove the filter. Filter clearance requirements are illustrated in Technical Data. Provide sufficient space for wrench clearance around the nozzle. Mount the gun on a rigid support that is isolated from external vibrations and that prevents the gun from rotating. Insulate the gun from the support using the insulator provided with the gun. Hydraulic Connections Use only one fitting to connect the e.dot hose to the e.dot gun. Insulate the hose-to-gun joint Nordson Corporation
19 e.dot Gun 15 Mounting the Gun See Figure 2 and Figure 12 or Slide the gun mounting clamps (1) onto a 9-mm ( 3 / 8 in.) mounting bar (2), or disassemble the clamps and reassemble them (with the gun and insulators) onto the mounting bar. Ensure that the insulator (3) is placed between the body of the gun and the clamps. See Figure 3. Alternately, you can mount the gun using the two 4.2 mm (0.165 in.) mounting holes provided in the gun body. 2. Securely tighten the mounting clamp. Figure 2 Mounting the gun on a mounting bar 19.8 mm (0.78 in.) 37.7 mm (1.48 in.) 4.2 mm (0.165 in.) 47.7 mm (1.88 in.) 18.9 mm (0.74 in.) Figure 3 Alternate gun mounting holes 2006 Nordson Corporation
20 16 e.dot Gun Mounting the Gun Driver/Pattern Control Connecting the Hose Refer to the following product manuals for information about how to mount the gun driver or pattern control. P/N e driver P/N e driver2, e driver3, and e driver4 P/N LA4400 NOTE: Refer to the user s guide (P/N ) that is shipped with the e.dot hose for information about installing the hose. CAUTION: Always use two wrenches, one on each fitting to tighten the hose fitting. See Figure Connect the swivel fitting on the e.dot hose to the fitting located on the top or rear of the gun body. Tighten securely. 2. Connect the swivel fitting on the opposite end of the hose to the melter. Refer to the product manual provided with the melter for information about connecting hoses. Figure 4 Connecting the e.dot hose to the e.dot gun 2006 Nordson Corporation
21 e.dot Gun 17 Connecting Hose Cordsets See Figure Connect the hose cordset to the gun cordset (The gun-end of the hose has only one cordset.). Figure 5 Connecting the hose cordset to the gun cordset See Figure Connect the appropriate interface cable to the hose cordset at the melter-end of the e.dot hose (The melter-end of the hose has two cordsets). 3. Connect the other end of the interface cable to the driver/pattern control as follows: LA4400 or e driver2, 3, or 4 Connect the interface cable plug to the current mode output receptacle. The interface cable is 10 m (33 ft.) in length. e driver Connect the fly-lead end of the interface cable to the input terminal block (removable) that is located on the top of the e driver. Refer to Tables 3, 4 and 5 for wiring information. The interface cable is 15 m (49 ft.) in length. NOTE: Extension cable P/N can be used to extend the distance between the driver/pattern control interface cable and the hose cordset by 10 m (33 ft.) Nordson Corporation
22 18 e.dot Gun Connecting Hose Cordsets (contd) Figure 6 Connecting the hose cordset to the driver/pattern control 2006 Nordson Corporation
23 e.dot Gun 19 NOTE: The white/black wire pair is not used. Table 3 Terminal Block Connections for one e.dot gun Terminal Lead SHIELD Shield Blank COIL Red or Black SERIES + COIL Red or Black Table 4 Terminal Block Connections for Two e.dot guns Terminal SHIELD Blank COIL SERIES Purpose Both shields Gun 1 Red lead ( ) Gun 1 Red (+) and Gun 2 Black ( ) + COIL Gun 2 Red (+) Table 5 Terminal Block Connections for Three e.dot guns Terminal SHIELD Blank COIL SERIES Purpose Shield Gun 1 Black ( ) + COIL Gun 3 Red (+) NOTE: Wire three guns in series: Join Gun 1 Red (+) and Gun 2 Black ( ). Join gun 2 Red (+) and Gun 3 Black ( ). Use wire nuts or other suitable means Nordson Corporation
24 20 e.dot Gun Connecting Hose Cordsets (contd) See Figure Connect the e.dot hose cordset to the melter. Refer to the hose user s guide and/or the melter product manual as needed. Figure 7 Connecting the hose cordset to the melter (ProBlue 4 shown) 2006 Nordson Corporation
25 e.dot Gun 21 Connecting an EPC-30 to the e driver2, 3, or 4 (Optional) An Eclipse EPC-30 pattern control can be connected to the e driver2, 3, and 4 to provide an input signal. Figure 8 illustrates how to wire an e driver2, 3, and 4, which has an internal 24 VDC power supply, to an EPC-30 for a single-gun application. If an e driver2, 3, or 4 without an internal power supply is used, you must provide an external 24 VDC power source to the EPC-30. NOTE: A 24 VDC power supply can be added to e drivers that have no power supply. Order kit P/N X7 P/N Figure 8 Connecting an EPC-30 to the e driver2, 3, or 4 (single gun wiring shown) 2006 Nordson Corporation
26 22 e.dot Gun Operation The e.dot gun is now ready for operation. Melter Adjustment Adjust the set-point temperature of the gun to a maximum of 185 C (365 F). Refer to the melter product manual for information about how to adjust the gun set-point temperature. Driver Electrical Adjustment The e.dot gun is designed for optimal performance when operated with the electrical characteristics shown in Table 6. Table 6 e.dot Electrical Characteristics Characteristic Value Peak Current (spike) 2.85 A Peak current time (spike time) 1.35 ms Hold current.75 A e driver and e driver2, 3, and 4 The e driver and e driver2, 3, and 4 are factory set to the values shown above and require no electrical adjustment. LA4400 The LA4400 must be set to the current values shown in Table 6. Refer to the product manual provided with the LA4400 for information about how to adjust these values Nordson Corporation
27 e.dot Gun 23 Dot Size Adjustment e driver The relative size of the adhesive dot that is dispensed from an e.dot gun will increase as the duration that the gun remains open increases. Before operating the e.dot gun, you must set the duration on the driver. On an e driver and an e driver2, 3, and 4, the duration is referred to as DOT Time. On an LA4400, the duration is referred to as On Time. e driver and e driver2, 3, and 4 Use the DOT time switch to set the DOT time. The top switch has a resolution of 0.5 ms and a range of ms. The bottom switch has a resolution of 0.05 ms and a range of ms. Together, both switches provide a DOT time range of ms. DOT time adjustment swtiches (e driver and e driver2, 3, 4 only) NOTE: The DOT time function is turned off when both switches are set to 0.0 ms. LA4400 To control and e.dot gun using an LA4400, set the LA4400 to Dotted mode and enter an appropriate On time. Refer to the LA4400 product manual or help screens for additional information. Pattern Control Adjustment EPC-30 Refer to the EPC-30 product manual for information about how to set up a pattern. LA4400 Set the desired gun to operate in Dotted mode. Refer to the LA4400 product manual for information about how to set up a dot pattern Nordson Corporation
28 24 e.dot Gun Stroke Adjustment The gun is equipped with a stroke adjustment dial. The stroke is factory-set to 0.2 mm. Under normal operating conditions, it is not necessary to adjust the stroke of the gun. Stroke adjustment is only required if the gun is disassembled. Refer to Maintenance, Rezeroing the Gun. CAUTION: Do not use the stroke adjustment to turn off the flow of adhesive from the gun. Stroke adjustement dial 2006 Nordson Corporation
29 e.dot Gun 25 Troubleshooting WARNING: Risk of Burns! Do not remove the nozzle when the system is pressurized. Removing the nozzle when the system is pressurized will cause hot melt to free-flow from the gun. Relieve system pressure before removing the nozzle. Failure to relieve system pressure can result in personal injury. WARNING: Risk of personal injury. This equipment contains pressurized hot melt material and high voltage circuits. Read the Safety information provided in this document before completing any troubleshooting procedure. Failure to observe safety messages and hazard-avoidance procedures can result in personal injury, including death. Troubleshooting Table The following table lists the gun problems that are most likely to occur, the possible causes of each problem, and steps for corrective action. Where applicable, cross-references are made to expanded diagnostic procedures (DPs) provided later in this section or to other sections of this manual. Problem Possible Cause Corrective Action No adhesive flow Adhesive level low Check level. Add adhesive if needed No input power Melter temperature setting too low Hose temperature controller setting too low Gun temperature controller setting too low System not at operating temperature Air pressure to pump off or low (piston pump) Connect power to melter and associated equipment. Make sure that all circuit breakers are switched on Adjust setting (refer to melter manual) Adjust setting (refer to melter manual) Adjust setting (refer to melter manual) Verify if the READY light is on and adhesive or sealant is molten. If not, allow unit to reach operating temperature Restore or adjust piston pump air pressure Continued Nordson Corporation
30 26 e.dot Gun Troubleshooting Table (contd) Problem Possible Cause Corrective Action No adhesive flow (continued) Gun fails to heat or underheats Gun overheats Melter motor not operating (gear pump) Hose clogged Nozzle clogged Gun coil faulty No power or low line voltage Temperature setting too low Failed heater cartridge (open or shorted) Failed RTD (open or shorted) Melter tank temperature setting too low Hose temperature controller setting too high Gun temperature controller setting too high Shorted RTD (melter should fault) Verify motor operation (refer to melter manual) Clean or replace hose (refer to hose user s guide) Clean or replace nozzle Check that the resistance of the coil at room temperature is ohms. Replace the gun module if necessary Make sure that input power is connected and all circuit breakers switched ON. Check voltage at unit input and gun output Adjust setting Test heater resistance. Replace if defective Check continuity. If continuity exists, check resistance Replace RTD if defective Adjust setting (refer to melter manual) Adjust setting (refer to melter manual) Adjust setting (refer to melter manual) Test the RTD. Replace if defective Continued Nordson Corporation
31 e.dot Gun 27 Problem Possible Cause Corrective Action Gun fails to close Debris or contamination in seat Remove and clean the nozzle and armature. Refer to Maintenance, Cleaning/Replacing the Nozzle and the Armature Gun closes prematurely Drip forms on nozzle Damaged return spring Low input voltage to gun driver Incorrect gun driver setting Tip of nozzle damaged Nozzle too close to substrate Replace the return spring Verify the cause of low input voltage and correct it Check settings (refer to gun driver manual) Replace the nozzle Increase gap to 4 6 mm Inconsistent bead pattern Dirt or debris in nozzle, filter, or on needle Clean or replace parts as needed 2006 Nordson Corporation
32 28 e.dot Gun Maintenance To maintain optimal gun performance, complete the maintenance tasks listed in Table 7. Table 7 Gun Maintenance Schedule Task When... Clean or replace the nozzle, armature, and spring Rezero the Gun Change the filter Adhesive flow is reduced or stops Poor bead quality/size After nozzle is replaced Reduced adhesive flow Cleaning/Replacing the Nozzle and the Armature WARNING: Risk of Burns! Do not remove the nozzle when the system is pressurized. Removing the nozzle when the system is pressurized will cause hot melt to free-flow from the gun. Relieve system pressure before removing the nozzle. Failure to relieve system pressure can result in personal injury. Remove the nozzle, spring and armature 1. Heat the gun to operating temperature. 2. Disable the gun. Refer to Safety. See Figure Remove the nozzle, spring (2) and armature (3) Nordson Corporation
33 e.dot Gun Figure 9 Removing the nozzle (1), armature (2), and spring (3) Clean the components WARNING: Risk of fire. Do not heat Nordson Type R fluid above 245 C (475 F). Use only an industrial grade, regulated, electrical heating device that is designed to heat industrial fluids. Personal injury or property damage can result if Type R cleaning fluid is heated with an open flame or in an unregulated heating device. 1. Soak the components in Nordson Type R cleaning fluid that has been heated above the melting point of the hot melt. 2. Remove the components from the cleaning fluid and clean thoroughly with a soft cloth to remove all foreign material Nordson Corporation
34 30 e.dot Gun Cleaning/Replacing the Nozzle and the Armature (contd) CAUTION: Use the correct size precision pin probe to clean Nordson nozzles. The use of non-precision or incorrectly sized probes may damage the nozzle. The Nordson nozzle cleaning kit (P/N ) contains a variety of probe sizes. 3. At the outlet of the nozzle, insert a correctly sized cleaning probe. 4. With a clean cloth, firmly grip the cleaning probe, then pull the probe out of the nozzle, wiping the probe clean. 5. Clean the armature and spring. 6. Inspect all of the components for damage or excessive wear. Replace if necessary. Refer to Parts, Gun Service Kits. Cleaning the nozzle NOTE: Over time, the nozzle and the armature and nozzle (seat) will wear down and develop a matched fit. If either the nozzle or the armature needs to be replaced, Nordson Corporation recommends that all three components (nozzle, armature, and spring) be replaced. Re-install the components 1. Turn the stroke adjustment dial to 0.3 mm. 2. Re-install the spring and armature into the module. CAUTION: Do not overtighten the nozzle. To avoid applying excessive torque to the nozzle, use the shortest wrench available. Stroke adjustement dial 3. Check the nozzle O-ring for damage or deterioration. Replace if necessary. 4. Re-install the nozzle and tighten it to 3 4 Nm (2 3 ft.-lb). 5. Go to Rezeroing the Gun Nordson Corporation
35 e.dot Gun 31 Rezeroing the Gun 1. Heat the gun to operating temperature. See Figure Use a 1. 5 mm hex key to loosen the dial set screw (3) CAUTION: Do not overtighten the stroke adjustment screw. Overtightening the screw can damage the seat. 3. Using the long end of a 3 mm hex key, held by two fingers, turn the stroke adjustment screw (2) clockwise until it just stops. 4. Turn the dial (1) until the 0 indication is aligned with the reference mark (4) on the side of the module. 5. Tighten the dial set screw. 6. Turn the dial to 0.2 mm. Figure 10 Module adjustment features 2006 Nordson Corporation
36 32 e.dot Gun Changing the Filter 1. Heat the gun up to its operating temperature. 2. Relieve system pressure. Refer to Safety. 3. Use a 5 mm hex key to remove the filter. NOTE: Dispose of the old filter. Filters are not serviceable. See Figure Apply Never-Seez to the threads of the new filter. 5. Install the new filter and tighten it to N m (1 2 ft-lb). Red/50 mesh (0.011 in.) P/N Yellow/100 mesh (0.006 in.) P/N Purple/200 mesh (0.003 in.) P/N NOTE: To prevent nozzle clogging, ensure that the filter mesh size is smaller than the nozzle orifice size. Figure 11 Installing the filter (Left top feed/right rear feed) 2006 Nordson Corporation
37 e.dot Gun 33 This page intentionally left blank Nordson Corporation
38 34 e.dot Gun Removing the Cordset See Figure Relieve hydraulic pressure and de-energize the system. Refer to Safety. 2. Remove the two socket head screws (1) that secure the cordset to the manifold. 3. Take hold of the slide cover (8), and pull it away from the manifold. 4. Remove the round connector (2), the heater (3) and RTD (4). Installing the Cordset See Figure Slide the heater (3) into the heater cavity (7). 2. Position the RTD (4) to the left side of the round connector (2), and then slide the RTD into the RTD cavity (6). 3. Push the round connector (2) into the connector cavity of the manifold (5) by pushing the slide cover (8) into place. 4. Fasten the two socket head screws (1) Nordson Corporation
39 e.dot Gun Figure 12 Cordset Replacement 2006 Nordson Corporation
40 36 e.dot Gun Parts e.dot Gun Components Figure 13 e.dot gun components 2006 Nordson Corporation
41 e.dot Gun 37 Item Part Description Quantity Note Gun, top feed, round connector, 0.25 mm nozzle Gun, top feed, round connector, 0.3 mm nozzle Gun, top feed, round connector, 0.35 mm nozzle Gun, rear feed, round connector, 0.25 mm nozzle Gun, rear feed, round connector, 0.3 mm nozzle Gun, rear feed, round connector, 0.35 mm nozzle Module with 0.25 mm nozzle 1 A Module with 0.3 mm nozzle 1 A Module with 0.35 mm nozzle 1 A 2 Spring 1 B 3 Armature 1 B 4 O-ring 1 B, E 5 Nozzle 1 B, C 6 Seal 1 B 7 Seal 1 B Cordset, round connector, w/heater and RTD 1 9 Filter, gun, integrated 1 D Connector, with O-ring, 9 / Elbow, 45 degree, 9 / Bracket assembly, mounting, clamp, H O-ring, Viton, 5.28 x 1.78 mm 1 B, F 14 Screw, socket, M4 x 25 2 B 15 Screw, socket, M3 x 45 1 B NOTE A: Includes mounting screws (items 14 and 15). B: Included in module service kit P/N C: Nozzles (with O-ring) also sold separately. Refer to Nozzles. D: Three mesh sizes available. Refer to Filters. E: Pack of 10 P/N F: Pack of 10 P/N Nordson Corporation
42 38 e.dot Gun Gun Service Kits Part Description Kit, service, module, e.dot Kit, armature, spring, 0.25 mm nozzle Kit, armature, spring, 0.3 mm nozzle Kit, armature, spring, 0.35 mm nozzle Kit, cordset, round connector, w/heater and RTD Kit, service, O-ring, 10 pc., seal, nozzle, e.dot Nozzles Part Description Nozzle, 0.25 mm, with O-ring Nozzle, 0.3 mm, with O-ring Nozzle, 0.35 mm, with O-ring Kit, service, O-ring, 10 pc., seal, module-to-gun, e.dot Filters Part Kit, filter, gun, 50 mesh Kit, filter, gun, 100 mesh Kit, filter, gun, 200 mesh Description e.dot Small Diameter Hoses Part Hose, 2 m (6.56 ft.) Hose, 3.5 m (11.5 ft.) Hose, 5 m (16.4 ft.) Description 2006 Nordson Corporation
43 e.dot Gun 39 e drivers Part Description Gun driver, e, 4-module, with power supply Gun driver, e, 4-module, without power supply Gun driver, e, 3-module, with power supply Gun driver, e, 3-module, without power supply Gun driver, e, 2-module, with power supply Gun driver, e, 2-module, without power supply Gun driver, e, single box e driver cables Part Description Cable, e.dot, 15 m (49.2 ft.), e.dot hose to e driver Cable, e.dot, 10 m (33 ft.), e.dot hose to LA4400/e driver2, 3, Cable, extension, e.dot hose to P/N or P/N , 10 m (33 ft.) Cable, e driver2, 3, 4 to EPC Nordson Corporation
44 40 e.dot Gun Technical Data The following technical data is provided for your reference as needed. Gun Specifications Item Service life Response time Maximum hydraulic pressure Working hydraulic pressure Working viscosity Maximum viscosity Maximum operating temperature 200 million cycles 2 ms 100 Bar (1450 psi) 48.3 Bar (700 psi) 1000 cps 5000 cps 185 C (365 F) Description Gun Dimensions Figure 14 Top-feed e.dot gun dimensions 2006 Nordson Corporation
45 e.dot Gun 41 Figure 15 Rear-feed e.dot gun dimensions Gun Wiring Diagram Figure 16 e.dot gun wiring 2006 Nordson Corporation
46 42 e.dot Gun Cable Wiring Diagrams Figure 17 e.dot cable diagrams 2006 Nordson Corporation
Repair Kit Control Module EP 10
Repair Kit Control Module EP 10 Manual English Issued 05/06 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY NOTE This manual is for products with the following P/N: 40470 446979 466441 466445 7106487 Order number
More informationPatternJet Adhesive Dispensing Gun
PatternJet Adhesive Dispensing Gun Customer Product Manual Issued 3/06 NORDSON CORPORATION DULUTH, GEORGIA USA www.nordson.com For CE Declaration, refer to melter manual. Nordson Corporation welcomes requests
More informationExchangeable Nozzle with Rotating Bar
Exchangeable Nozzle with Rotating Bar Manual English Issued 11/09 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This document is for products with the following P/N: 7153637 7162615 7160422 7158262 7160141
More informationE400 Electric Applicator
E400 Electric Applicator Customer Product Manual Issued 7/05 NORDSON CORPORATION DAWSONVILLE, GEORGIA USA www.nordson.com For CE Declaration, refer to melter manual. Nordson Corporation welcomes requests
More informationE-900 Electric Guns. Customer Product Manual Part A. Issued 6/03. NORDSON CORPORATION DULUTH, GEORGIA USA
E-900 Electric Guns Customer Product Manual Issued 6/0 NORDSON CORPORATION DULUTH, GEORGIA USA www.nordson.com For CE Declaration, refer to melter manual. Nordson Corporation welcomes requests for information,
More informationSP30 10:1 Piston Pump
Instruction Sheet P/N SP30 10:1 Piston Pump 1. Safety Read this section before using the equipment. This section contains recommendations and practices applicable to the safe installation, operation, and
More informationBravura Adhesive Melters
Bravura Adhesive Melters Customer Product Manual Part 052743D 03 Issued 2/0 NORDSON CORPORATION DULUTH, GEORGIA USA www.nordson.com Nordson Corporation welcomes requests for information, comments, and
More informationMiniBlue Guns. Customer Product Manual Part A02. Issued 1/08. NORDSON CORPORATION DULUTH, GEORGIA USA
MiniBlue Guns Customer Product Manual Issued 1/08 NORDSON CORPORATION DULUTH, GEORGIA USA www.nordson.com For CE Declaration, refer to melter documentation. Nordson Corporation welcomes requests for information,
More informationAG900+ and AG900+S Applicators
AG900+ and AG900+S Applicators Customer Product Manual Issued 9/09 For CE Declaration, refer to melter manual. Nordson Corporation welcomes requests for information, comments, and inquiries about its products.
More informationWorld Gun Series. Customer Product Manual Part C. Issued 11/03. NORDSON CORPORATION DULUTH, GEORGIA USA
World Gun Series Customer Product Manual Issued 11/03 NORDSON CORPORATION DULUTH, GEORGIA USA www.nordson.com For CE Declaration, refer to melter manual. Nordson Corporation welcomes requests for information,
More informationAutomatic Hopper/Feeder for Piston Pump Units
Automatic Hopper/Feeder for Piston Pump Units Customer Product Manual Issued 1/06 NORDSON CORPORATION DULUTH, GEORGIA USA www.nordson.com Nordson Corporation welcomes requests for information, comments,
More informationVersaBlue Adhesive Melters with Allen-Bradley CompactLogix Control System, Models VA and VT
VersaBlue Adhesive Melters with Allen-Bradley CompactLogix Control System, Models VA and VT Customer Product Manual Issued 8/05 NORDSON CORPORATION DAWSONVILLE, GEORGIA USA www.nordson.com Nordson Corporation
More informationUniversalt Controlled Fiberizationt (CFR) Spray Nozzles
Universalt Controlled Fiberizationt (CFR) Spray Nozzles Customer Product Manual Issued 7/11 This document contains important safety information Be sure to read and follow all safety information in this
More informationAuto-Flo Air-Assist Automatic Dispensing Valve
Auto-Flo Air-Assist Automatic Dispensing Valve Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its
More informationUniversal Allegro Elastic Coating Nozzles
Universal Allegro Elastic Coating Nozzles Customer Product Manual Issued 2/15 This document contains important safety information Be sure to read and follow all safety information in this document and
More informationVolume Metering Head GMG
Volume Metering Head Manual - English - Edition 11/10 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This document applies to the entire series. Order number P/N = Order number for Nordson articles Note
More informationUniversalt Summitt Spray Nozzles
Universalt Summitt Spray Nozzles Customer Product Manual Issued 7/11 This document contains important safety information Be sure to read and follow all safety information in this document and any other
More informationAuto-Flo Panel Reinforcement Automatic Dispensing Valve
Auto-Flo Panel Reinforcement Automatic Dispensing Valve Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries
More informationHotmelt Applicators Speed Coat
Hotmelt Applicators Speed Coat Parts List - English - Issued 03/2 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This document is valid for the entire series. Order number P/N = Order number for Nordson
More informationBlue Series Pneumatic Applicators
Blue Series Pneumatic Applicators Customer Product Manual Issued 12/15 This document contains important safety information Be sure to read and follow all safety information in this document and any other
More informationUniversalt SignatureR Spray Nozzles (Continuous Applications)
Universalt SignatureR Spray Nozzles (Continuous Applications) Customer Product Manual Issued 10/11 This document contains important safety information Be sure to read and follow all safety information
More informationUniversalt SureWrapR Spray Nozzles
Universalt SureWrapR Spray Nozzles Customer Product Manual Issued 7/11 This document contains important safety information Be sure to read and follow all safety information in this document and any other
More informationVersaBlue Adhesive Melters VBN with Siemens Controller
VersaBlue Adhesive Melters VBN with Siemens Controller Manual English Issued 12/07 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This document applies to the entire series. Order number P/N = Order number
More informationMulti e.dot+ Gun. Manual P/N B - English - Edition 10/11 NORDSON DEUTSCHLAND GMBH ERKRATH GERMANY
Multi e.dot+ Gun Manual - English - Edition 10/11 NORDSON DEUTSCHLAND GMBH ERKRATH GERMANY Note This document is for products with the following P/N: 7331102 7331103 7331104 7331105 7331106 7331107 7331108
More informationOPERATOR S CARD. Select Series H-400 Hot Melt Dispensing Guns. Safety. Description/Intended Use. Nordson Corporation P/N E
Nordson Corporation OPERATOR S CARD P/N 32 96E Select Series H-400 Hot Melt Dispensing Guns Safety WARNING: System pressurized! Relieve system hydraulic pressure before breaking any hydraulic connection
More informationSeries H-200 Guns. Customer Product Manual Part K. Issued 8/05. NORDSON CORPORATION DULUTH, GEORGIA USA
eries H-200 Guns Customer Product Manual Issued 8/05 NORDON CORPORATION DULUTH, GEORGIA UA www.nordson.com For CE Declaration, refer to melter manual. Nordson Corporation welcomes requests for information,
More informationMelter MC 20 / MC 21 with Foil Bag
Melter MC 20 / MC 21 with Foil Bag Manual English Issued 05/06 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This document applies to the entire series, beginning with serial number LU03K07512. Order
More informationSeries 3700VMPD Hot Melt Material Applicator
Series 3700VMPD Hot Melt Material Applicator with DC Pump, L Manifold, and Vista Controller Customer Product Manual Part NORDSON CORPORATION Duluth, Georgia www.nordson.com Nordson Corporation welcomes
More informationElectropneumatic Hot Melt Application Heads EP 25 / EP 25 S / EP 25 SD
Electropneumatic Hot Melt Application Heads Manual P/N 409 017 A - English - NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for
More informationElectro-pneumatic Hot Melt Applicator EP 45
Electro-pneumatic Hot Melt Applicator EP 45 Manual - English - Edition 06/11 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This document applies to the entire series. Order number P/N = Order number for
More informationVersaBlue Adhesive Melters VBN with Allen Bradley Controller
VersaBlue Adhesive Melters with Allen Bradley Controller Manual English Issued 03/08 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This document applies to the entire series. Order number P/N = Order
More informationHot Melt Applicators EP 11 / EP 11 N EP 12 V / EP 12 L / EP 12 RV
Hot Melt Applicators EP 11 / EP 11 N EP 12 V / EP 12 L / EP 12 RV Manual - English - Issued 03/11 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This document is valid for the entire series. Order number
More informationGear Pump Metering Station GP 200 (Mini)
Gear Pump Metering Station GP 200 (Mini) Manual English Issued 01/09 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson
More informationHot Melt Adhesive Applicators TrueCoat
Hot Melt Adhesive Applicators TrueCoat Parts List English Issued 07/0 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Bestellnummer P/N = Bestellnummer für Nordson Artikel Hinweis Dies ist eine urheberrechtlich
More informationEnviroCoat Screener. Vibratory Sieves. Manual P/N English- Keep for Future Reference. Nordson (China) Co., Ltd. China Sourcing Operation
EnviroCoat Screener Vibratory Sieves Manual P/N 9 56 -English- Keep for Future Reference Nordson (China) Co., Ltd. China Sourcing Operation Order number P/N = Order number for Nordson products Notice This
More informationParts List DuraPail Bulk Melters DP020
Parts List DuraPail Bulk Melters DP020 Parts List English Issued 0/09 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Hinweis Diese Betriebsanleitung ist für die gesamte Baureihe gültig. Order number P/N = Order
More informationFines Separator. Manual P/N A English. Keep for Future Reference. Issued 05/03 NORDSON (UK) LTD. STOCKPORT
Manual P/N 397 379 A English Issued 05/03 Keep for Future Reference NORDSON (UK) LTD. STOCKPORT Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation publication which
More informationSeries H-200 Mini-Bead Applicators
Series H-200 Mini-Bead Applicators Customer Product Manual Issued 9/15 NORDSON CORPORATION DULUTH, GEORGIA USA www.nordson.com For CE Declaration, refer to melter manual. Nordson Corporation welcomes requests
More informationSP30 21:1 Piston Pump
SP30 21:1 Piston Pump Installation and Maintenance Instructions Part NORDSON CORPORATION Duluth, Georgia www.nordson.com Nordson Corporation welcomes requests for information, comments and inquiries about
More informationVersaBlue Adhesive Melters Serie N Model VB, VC, VD, VE, VW, VX, VY, VZ
VersaBlue Adhesive Melters Serie N Model VB, VC, VD, VE, VW, VX, VY, VZ Manual English Issued 03/08 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Hinweis Diese Betriebsanleitung ist für die gesamte Baureihe
More informationHot Melt Applicators Series EP 48 V (UL Models)
Hot Melt Applicators Series EP 48 V (UL Models) Manual - English - Edition 05/14 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This document applies to products with the following P/Ns: 7154401 7154402
More informationPressure Controller LA 302
Pressure Controller Manual English NORDSON BENELUX MAASTRICHT THE NETHERLANDS www.nordson.com This equipment is regulated by the European Union under WEEE Directive 2002/96/EC. www.nordson.com See www.nordson.com
More informationLS 373 Liquid Adhesive Gun
LS 373 Liquid Adhesive Gun Manual English Issued 12/09 NORDSON BENELUX MAASTRICHT THE NETHERLANDS Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation publication which
More informationHot Melt Applicators TrueCoat HP
Hot Melt Applicators TrueCoat HP Manual - English - Edition 02/14 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This document applies to the entire series. Order number P/N = Order number for Nordson
More informationNormally Open H200 and 90_ CF200 Module Seal Rebuild Kit
Instruction Sheet 108 792A Normally Open H200 and 90_ CF200 Module Seal Rebuild Kit 1. Description Use this rebuild kit to service the following modules: S Normally Open H200 (N.O. H200) Module -- P/N
More informationNORDSON CORPORATION DULUTH, GEORGIA USA
NORDSON CORPORATION DULUTH, GEORGIA USA www.nordson.com Notice Trademarks AccuJet, AeroCharge, Apogee, AquaGuard, Asymtek, Automove, Baitgun, Blue Box, CanWorks, Century, CF, Clean Coat, CleanSleeve, CleanSpray,
More informationHot Melt Applicator TrueCoat HP with Adjustable Application Width
Hot Melt Applicator TrueCoat HP with Adjustable Application Width Manual - English - Edition 11/15 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This document applies to the entire series. Order number
More informationProdigy HDLV Pump. Customer Product Manual Part A02
Prodigy HDLV Pump Customer Product Manual Issued 1/07 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson representative.
More informationExtruder EEX Economic Series
Extruder Economic Series Manual - English - Edition 05/14 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This document applies to the entire series. Order number P/N = Order number for Nordson articles
More informationHot Melt Material Applicators MX 3400 / MX 4400
Hot Melt Material Applicators Manual P/N 290 842 C English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products
More informationFilter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an out-in filter.
Filter 10-1 Section 10 Filter NOTE: This section applies to applicators with an out-in filter. Table of Contents Filter...................................................... 10-1 Introduction................................................
More informationMaintenance. Part A, Section 5. This section covers the following unit configurations.
Part A, Section 5 This section covers the following unit configurations. Model 3100V 3400V 3830V 3860V 3890V 3930V Voltage 1, 2 Pump AC Gear (K or L) Manifold 4-Port (J)) Control Vista Standard (V) Vista
More informationProdigy HDLV Pump Manifold and Circuit Board
Prodigy HDLV Pump Manifold and Circuit Board Customer Product Manual Issued 05/08 For parts and technical support, call the Finishing Customer Support Center at (800) 433-939. This document is available
More informationBulk Melters VersaDrum VD200 (P/N , , ) with Allen Bradley Controller
Bulk Melters VersaDrum VD200 (P/N 7144289, 7155290, 7177185) with Allen Bradley Controller Manual - English - Issued 07/12 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This document is for products with
More informationSeries 5000 Drum Melter/Applicators
Series 5000 Drum Melter/Applicators Model 5544 Customer Product Manual Part NORDSON CORPORATION DULUTH, GEORGIA USA www.nordson.com Nordson Corporation welcomes requests for information, comments and inquiries
More informationUM3 Dispensing Module (Flange-Mounted Solenoid)
UM3 Dispensing Module (Flange-Mounted Solenoid) Customer Product Manual Issued 4/15 This document contains important safety information Be sure to read and follow all safety information in this document
More informationModule. Table of Contents. Section 9. Module NOTE: This section applies to applicators with bead or slot modules.
9-1 Section 9 NOTE: This section applies to applicators with bead or slot modules. Table of Contents... 9-1 Introduction... 9-3 Overview... 9-7 Service... 9-9 Adjusting a ClassicBlue Zero-Cavity... 9-9
More informationTruFlow Applicator UTA... Flow Divider and Flow Meter
TruFlow Applicator UTA... Flow Divider and Flow Meter Manual - English - Edition 12/14 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This document applies to the entire series. Order number P/N = Order
More informationSure Coat Modular Gun Control System Part B: Pneumatic Modules. Customer Product Manual Part B
Sure Coat Modular Gun Control System Part B: Pneumatic Modules Customer Product Manual Issued 4/03 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800)
More informationElectrostatic Cable Coater ECC301
Electrostatic Cable Coater Manual P/N 464 886 B English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products Notice
More informationSeries H-400 Guns. Customer Product Manual Part D. NORDSON CORPORATION D Duluth, Georgia
eries H-400 Guns Customer Product Manual Part NORDON CORPORATION D Duluth, Georgia www.nordson.com For CE Declaration, refer to melter manual. Nordson Corporation welcomes requests for information, comments
More informationFilter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an in-out filter.
Filter 10-1 Section 10 Filter NOTE: This section applies to applicators with an in-out filter. Table of Contents Filter...................................................... 10-1 Introduction................................................
More informationEcoLiner Compound Gun
EcoLiner Compound Gun Customer Product Manual Issued 3/06 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson representative.
More informationPro Meter VDK Dispensing System
Pro Meter VDK Dispensing System Customer Product Manual Issued 7/14 This document contains important safety information Be sure to read and follow all safety information in this document and any other
More informationApplicators in the Series TC FS Generation 2 Application Widths 500 mm with Handwheel
Applicators in the Series TC FS Generation 2 Application Widths 500 mm with Handwheel Preliminary Manual - English - Edition 11/14 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This document applies to
More informationRoll Fed Labeling System
Roll Fed Labeling System Customer Product Manual Issued 4/15 This document contains important safety information Be sure to read and follow all safety information in this document and any other related
More informationApplicators in the Series TC FS Generation 2 with Grammage Control (Option)
Applicators in the Series TC FS Generation 2 with Grammage Control (Option) Manual - English - Edition 06/14 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This document applies to products with the following
More informationCirculating and Non-Circulating Color Change Manifolds
Circulating and Non-Circulating Color Change Manifolds Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about
More informationOPERATOR S CARD. Select Series H-440 Hot Melt Dispensing Guns. Safety. Description. Nordson Corporation P/N D
Nordson Corporation OPERATOR S CARD P/N 321 198D Select Series H-440 Hot Melt Dispensing Guns Safety WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions
More informationModule. Table of Contents. Section 9. Module NOTE: This section applies to applicators with CF200PAD right-angle modules.
9-1 Section 9 NOTE: This section applies to applicators with CF200PAD right-angle modules. Table of Contents.................................................... 9-1 Introduction................................................
More informationProdigy HDLV Generation II Pump Panel
Prodigy HDLV Generation II Pump Panel Customer Product Manual Issued 01/10 For parts and technical support, call the Finishing Customer Support Center at (800) 433-9319. This document is subject to change
More informationLP100 Fluid Application System
LP00 Fluid Application System Equipment Part 758 30 Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about
More informationVersaBlue Melters Types VA and VT
VersaBlue Melters Types VA and VT Manual - English - Edition 06/14 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This document applies to the entire series. Order number P/N = Order number for Nordson
More informationVersaBlue and VersaBlue Plus Melters in the Series N Types VB, VC, VD, VE, VW, VX, VY, VZ
VersaBlue and VersaBlue Plus Melters in the Series N Types VB, VC, VD, VE, VW, VX, VY, VZ Manual - English - Edition 02/14 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This document applies to the entire
More informationNordson/Drexelbrook Material Level Control Kit
Nordson/Drexelbrook Material Level Control Kit NORDSON CORPORATION. AMHERST, OHIO. USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence
More informationPowder Bell. Customer Product Manual Part A NORDSON CORPORATION AMHERST, OHIO USA
Powder Bell Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence
More informationE-350 Electric Gun. Customer Product Manual Part A NORDSON CORPORATION D AMHERST, OHIO D USA
E-350 Electric Gun Customer Product Manual Part 237 495A NORDON CORPORATION D AMHERT, OHIO D UA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address
More informationConverting an FP-200 Extrusion Gun to an FP-200 Swirl Gun
Instruction Sheet P/N 237494_02 Converting an FP-200 Extrusion Gun to an FP-200 Swirl Gun WARNING! Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this
More informationMELTEX Electropneumatic Hot Melt Application Head EP 26 SD
MELTEX Electropneumatic Hot Melt Application Head Manual P/N 409 097 A - English - NORDSON ENGINEERING GMBH LÜNEBURG GERMANY NOTE This manual applies to the entire series. Order number P/N = Order number
More informationInstalling an H-200 Integral Right-Angle Module
Instruction heet P/N 187 723A Installing an H-200 Integral Right-Angle Module WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this
More informationFilter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a Universal in-out filter.
Filter 10-1 Section 10 Filter NOTE: This section applies to applicators with a Universal in-out filter. Table of Contents Filter...................................................... 10-1 Introduction................................................
More information902 Powder Coating Booth
902 Powder Coating Booth Customer Product Manual Part For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson representative.
More informationManifold-Mounted to Flange-Mounted Solenoid Valve Conversion
Instruction Sheet P/N 106501A03 Manifold-Mounted to Flange-Mounted Solenoid Valve Conversion WARNING: Allow only personnel with appropriate training and experience to operate or service the equipment.
More informationAirless Spray Gun INSTRUCTIONS DP psi (345 bar) Maximum Working Pressure
INSTRUCTIONS DP-6376 Airless Spray Gun 5000 psi (345 bar) Maximum Working Pressure INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Table of Contents Warnings......................................
More information40:1 QS Pump System. Customer Product Manual Part A NORDSON CORPORATION D AMHERST, OHIO D USA
40:1 QS Pump System Customer Product Manual Part NORDSON CORPORATION D AMHERST, OHIO D USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. General information
More informationModule. Table of Contents. Section 9. Module NOTE: This section applies to applicators with MB200 modules.
9- Section 9 NOTE: This section applies to applicators with MB200 modules. Table of Contents.................................................... 9- Introduction................................................
More informationHigh-Pressure Fluid Filters
High-Pressure Fluid Filters Customer Product Manual Part 107971C02 NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products.
More informationSP30 6:1 Piston Pump. Installation and Maintenance Instructions. Part D NORDSON CORPORATION AMHERST, OHIO USA
Installation and Maintenance Instructions Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence
More informationNRPS-100 Rotary Sieve
NRPS-100 Rotary Sieve Customer Product Manual Part For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson representative.
More information5000 Gerotor Pump Service Instructions
Instruction Sheet P/N 237569B WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Introduction This
More informationE-200 Module Service Kit
Instruction Sheet E-200 Module Service Kit 1. Introduction These instructions describe how to remove and replace the E-200 module. The instructions include the following: S S S S Safety Unit Preparation
More informationSure Coat Modular Gun Control System Part D: Gun Purge Module. Customer Product Manual Part B
Sure Coat Modular Gun Control System Part D: Gun Purge Module Customer Product Manual Issued 4/0 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 4-919
More informationDISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A
INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. DISPLACEMENT PUMP 308190 Rev. K 3000 psi (210 bar) MAXIMUM WORKING PRESSURE Model
More informationBulk Melters VersaPail VP020 VersaDrum VD200 with Gear Pump and IPC Control Unit
Bulk Melters VersaPail VP020 VersaDrum VD200 with Gear Pump and IPC Control Unit Manual - English - Edition 12/14 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Order number P/N = Order number for Nordson articles
More informationEcono-Coat Manual Powder Spray Gun
Econo-Coat Manual Powder Spray Gun Customer Product Manual Issued 0/03 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-939 or contact your local
More informationVL400 Melters. Safety. Introduction. Nordson Corporation OPERATOR S CARD P/N A
Nordson Corporation OPERATOR S CARD P/N 052644A VL400 Melters Safety WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other
More informationReplacing a Gun RTD. Instruction Sheet P/N B. 1. Introduction. Using this Instruction Sheet
Instruction Sheet Replacing a Gun RTD WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation.
More informationStandard and Conical AN Series Air Spray Nozzles
Instruction Sheet P/N 107967E Standard and Conical AN Series Air Spray Nozzles Introduction The Nordson air spray nozzles described in this instruction sheet are categorized by their type of spray pattern:
More informationPreventive Maintenance for Pail Melters
Instruction Sheet P/N Preventive Maintenance for Pail Melters 1. Introduction These procedures are recommended in addition to the standard preventive maintenance. Use them to keep yourvista controlled
More informationTWO COMPONENT SYSTEM METERING VALVE
TWO COMPONENT SYSTEM METERING VALVE Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence