f-pod Intelligent Fuel Bowser

Size: px
Start display at page:

Download "f-pod Intelligent Fuel Bowser"

Transcription

1 f-pod Intelligent Fuel Bowser The f-pod is a new generation of race fuel bowser which raises the bar in technology, safety, accuracy and ease of use. The f-pod has been developed with input of leading UK single seater teams with total success. The f-pod is housed in a transport ready, heavy duty flight case with easy accessible compartments for the control panel and hoses. The f-pod sits on low friction anti-static castors which are bonded to the bowser s electrical ground.

2 Intelligent Control The f-pod uses a 7 colour touch-screen PC loaded with our bespoke software to control the bowser s functions. Our inspired step by step, graphical instructions means refuelling errors are a thing of the past. It also has a multifunction control switch to select internal battery, external battery, via an Anderson plug and battery charger. CE marking dictated that the bowser must not be operated by mains electricity so the battery charger is external and can only be operated when the bowser is switched off. 2

3 The f-pod had a configurable Operator Present Push to Pump button which means it can be set so all pumping operations require the button to be held pushed until the procedure is complete. Releasing the button will pause the operation. Use of Push to Pump to move fuel from the bowser to a fuel drum is compulsory. An Emergency Stop Button is standard on all machines. There is a USB socket included to download totals information when the totals option has been purchased. The control panel is part of an IP65, sealed electrical box which contains all of the electrical components and battery to help eliminate spark risk. All connection cables pass into the box though ATEX approved cable glands. The fuel tank is a fabricated from 3mm thick aluminium sheet, TIG welded together and pressure tested. All unions are -12 AN fittings. The tank bottom is tapered towards the outlet and drain plug to ensure it fully drains. The tank is bolted to a heavy duty loadcell and frame with over load stops and transport lock. The loadcell is 100% over-rated for reliability. The tank is connected, by high quality Aeroquip Startlite hose to a high volume explosion proof pump / motor assembly which includes its own internal filter and over-pressure valve. The pump then outputs via a 2 metre hose terminating in a -12 Staubli dry break connector. An anti-siphon valve assembly can be optioned, which connects to the output of the pump to prevent siphoning in either direction if the hoses are left connected to the car or fuel drum for any period of time. 3

4 A vent hose is connected to the top of the fuel tank via a bulkhead fitting in the hose compartment to a 2 metre hose terminating in a -8 Staubli dry break connector. CE demanded that there could be no open vent on the bowser, so the f-pod will breathe through the race cars own vent during refuelling or through the drum adaptors flame trap when connected to a fuel drum. When the bowser hoses are disconnected the system is completely sealed with no vapour loss. There is also an anti-static bonding cable from the bowser, which must be connected to the car or fuel drum before the hoses are connected. This again, is to reduce possible spark risk The f-pod software utilises special routines to check the state of the fuel hose at anytime. We can then compensate for a full or empty hose ensuring the accuracy of all fuel transfer totals 4

5 The software also monitors the level of fuel in the tank at any time both in kg and by percentage of capacity. The tank capacity can be factory set to any specific weight within its dimensional volume, allowing for an expansion factor with reference to the fuels specific gravity. This means it is impossible to overfill the tank, and strict regulation of capacity can be controlled. Fuel can be transferred to within a repeatable accuracy of 100g Optional extras Multiuser / Totals With this option, the f-pod can be used to fuel several different cars or drivers and keep an accurate record of all fuel transactions in and out of each particular car. This information is instantly viewable on the screen and is also downloadable via the USB port as a CVL file for further analysis. It will also record all fuel added and drawn from the bowser to and from fuel drums. 5

6 ATC Automatic Track Compensation Weight changes slightly depending where you are located in the world. Most weighing machines are calibrated in the region that they are going to be used so this error is never normally seen, but in motorsport, teams can be travelling to anywhere in the world, taking all their equipment with them. A bowser calibrated in Oxford will not read the same weight in Sao Paulo. 6

7 To solve this, the f-pod can be loaded with our unique ATC or Automatic Track Compensation software which will automatically correct this error when you select your current circuit location from the resident list. Anti-siphon An anti-siphon valve assembly can be optioned, which connects to the output of the pump to prevent siphoning in either direction if the hoses are left connected to the car or fuel drum for any period of time. Other Fuels The f-pod can be made to handle other fuels not included in the general specification. 7

8 General Specification f-pod Lite General Construction: Dimensions: Gross Weight Empty: Power Source: Max Current Draw: Max Power: Suitable Fuels: Ambient Temperature: Maximum Use Per Day: IP Rating: Noise: Vibration: Aluminium & Ply Flightcase Construction Mounted on Antistatic Castors. IP65 Sealed Steel Electrical Cabinet. 640w x 680d x 940h mm 91kg Internal 12Vdc 33Ahr AGM Battery 15Adc 180W Petrol up to 15% alcohol blends (E15), Diesel up to 20% bio-diesel blends (B20), and Kerosene. For other application contact EEC Performance Systems for advice degree C 3 Hours overall Control Panel IP65 Less than 70db(A) Does Not Exceed 2.5m/s² 8

9 We: Essential Equipment Consortium Ltd EC Declaration of Conformity In accordance with BS EN ISO/IEC :2010 Of: Unit 4, Maizefield, Hinckley Fields Ind Est, Hinckley, Leics. LE10 1YK. United Kingdom declare that: Equipment: Intelligent Race Fuel Bowser Model name/number: f-pod Lite FPL080 in accordance with the following Directives: 2004/108/EC 2006/42/EC 2002/95/EC Conforms with the essential performance requirements of the Electromagnetic Compatibility Directive and its amending directives Conforms with the essential health and safety requirements of the Machinery Directive and its amending directives Conforms with the requirements of the RoHS Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment has been designed and manufactured to the following specifications: EN ISO 12100:2010 Safety of machinery - General principles for design - Risk assessment and risk reduction EN :2011 Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology EN :2006 Electrical equipment for measurement, control and laboratory use - EMC requirements -- Part 1: General requirements EN :2006 Electromagnetic compatibility (EMC) -- Part 3-2: Limits - Limits for harmonic current emissions (equipment input current <= 16 A per phase) EN :2008 Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection I hereby declare that the equipment named above has been tested and found to comply with the relevant sections of the above referenced specifications. The unit complies with all relevant essential requirements of the Directives. Signed by:... Name:... Position:... Done at:... On:... This declaration of conformity is issued under the sole responsibility of Essential Equipment Consortium Ltd 9

10 Essential Equipment Consortium Ltd Unit 4, Maizefield, Hinckley Fields Ind Est, Hinckley, Leics, LE10 1YF Telephone: Facsimile:

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter Product Data Sheet February 2015 IP119, Rev CA Displacer Level Transmitter Level, contents or interface measurement transmitter Direct or external chamber mounting 4 20 ma HART output ATEX Intrinsically

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Overview Application The pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials guarantees compliance with

More information

DITCH KING & DITCH BOSS. Tractor Mounted Digger. Operation & Parts Manual

DITCH KING & DITCH BOSS. Tractor Mounted Digger. Operation & Parts Manual Publication 106 (Issue 4) October 1984 Part No. 7118850 Revision: January 1993 DITCH KING & DITCH BOSS Tractor Mounted Digger Operation & Parts Manual IMPORTANT VERIFICATION OF WARRANTY REGISTRATION DEALER

More information

c-go 24V/6A 24V/8A 24V/12A

c-go 24V/6A 24V/8A 24V/12A c-go 24V/6A 24V/8A 24V/12A Battery charger GB Instruction manual 1 Index 1. Product description... 2 2. Safety advices... 3 3. Quick start guide... 4 4. Operation... 4 5. Problem solving... 6 6. Specifications...

More information

Pressure Transmitters

Pressure Transmitters Transmitters Wetted parts are all made of stainless steel for high resistance to chemicals Stainless steel diaphragm welded with casing No seals and thus low leakage rate even with difficult gases High

More information

C:\Users\Steen Lauritzen\Dropbox\CTS - Citrotek\English quotation text\pharma\cp+10_1200 eng.doc

C:\Users\Steen Lauritzen\Dropbox\CTS - Citrotek\English quotation text\pharma\cp+10_1200 eng.doc C:\Users\Steen Lauritzen\Dropbox\CTS - Citrotek\English quotation text\pharma\cp+10_1200 eng.doc 13.10.2017-1 - CTS - Climatic Test Cabinet Type CP+10/1200 C:\Users\Steen Lauritzen\Dropbox\CTS - Citrotek\English

More information

EC400 Power Control System

EC400 Power Control System 1 Introduction This section of the handbook will guide you through the operation of the electrical system. Further technical details are contained in section 3 or in the supporting technical manual available

More information

Multi-Mover Charger for model L25

Multi-Mover Charger for model L25 Multi-Mover Charger for model L25 Important safety instruction. Keep these instructions. This manual contains important instructions for the safety of the user and the operation of the device. 1. SYMBOLS

More information

Compact Scales. Software Revision V1.25 & above

Compact Scales. Software Revision V1.25 & above Compact Scales Software Revision V1.25 & above 2016 1 Easy Reference: Model name of the scale: Serial number of the unit: Software revision number (Displayed when power is first turned on): Date of Purchase:

More information

Zone 1 Linear Range - Installation Guide

Zone 1 Linear Range - Installation Guide Zone 1 Linear Range - Installation Guide CML14ATEX3119 & IEC Ex CML15.0001 This installation guide provides instructions for installing SPARTAN series of explosion protected Zone 1 Linear luminaires. Text

More information

Explosion-Protected Pressure Switches

Explosion-Protected Pressure Switches Explosion-Protected Pressure Switches To new ATEX Standard TECHNICAL DATA 0165 0340 0341 Degree of protection: IP 65 ATEX protection zone: 1 22 22 Switching power: 1 A / 250 VAC 0.25 A / 250 VDC 2 A /

More information

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Type range: UN813.3ANI UN813.4ANI UN813.3ANDCB UN813.4ANDCB UN813.5ANI Fig. 1: UN813.3ANI Fig. 2: UN813.4ANI You have selected

More information

EC200 ELECTRONIC CONTROL SYSTEM

EC200 ELECTRONIC CONTROL SYSTEM 1 INTRODUCING THE EC200 ELECTRONIC CONTROL SYSTEM With the use of new technology and an innovative approach to user interfacing, the EC200 Power Control System provides a complete control solution for

More information

2018 CAMS MANUAL OF MOTOR SPORT

2018 CAMS MANUAL OF MOTOR SPORT 2018 CAMS MANUAL OF MOTOR SPORT GENERAL REQUIREMENTS OF AUTOMOBILES Schedule N Fuel Tanks and Refueling CONFEDERATION OF AUSTRALIAN MOTOR SPORT WWW.CAMS.COM.AU Modified Article Date of Application Date

More information

WOOOM INSTRUCTION MANUAL

WOOOM INSTRUCTION MANUAL WOOOM INSTRUCTION MANUAL Thank you very much for choosing the Wooom chair from Klöber! Please read this instruction manual carefully before using the chair. Please download the Wooom app to your device

More information

DATUM ELECTRONICS RS425 NON-CONTACT TORQUE TRANSDUCER PRODUCT OVERVIEW

DATUM ELECTRONICS RS425 NON-CONTACT TORQUE TRANSDUCER PRODUCT OVERVIEW DATUM ELECTRONICS LIMITED TELEPHONE: +44 (0) 1983 28 28 34 FAX: +44 (0) 1983 28 28 35 EMAIL: support@datum-electronics.co.uk WEB: www.datum-electronics.co.uk DATUM ELECTRONICS RS425 NON-CONTACT TORQUE

More information

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE W.CHRISTIE (INDUSTRIAL) LTD CHRISTIE HOUSE, MEADOWBANK ROAD, ROTHERHAM, SOUTH YORKSHIRE, S61 2NF, UK T: +44(0)1709 550088 F: +44(0)1709 550030 E:

More information

Instruction Manual. Back Pressure Regulator (Low Shear ¾ ) Bar Pilot Control

Instruction Manual. Back Pressure Regulator (Low Shear ¾ ) Bar Pilot Control Back Pressure Regulator (Low Shear ¾ ) 107757 15.0 Bar 107758 - Pilot Control Product Description This Product is designed for use with: BPR - 107757, 107758, 107748, 107749, 107750, 107754, 107755, PRV22,

More information

ISO INTERNATIONAL STANDARD. Tyres Electrical resistance Test method for measuring electrical resistance of tyres on a test rig

ISO INTERNATIONAL STANDARD. Tyres Electrical resistance Test method for measuring electrical resistance of tyres on a test rig INTERNATIONAL STANDARD ISO 16392 First edition 2007-10-15 Tyres Electrical resistance Test method for measuring electrical resistance of tyres on a test rig Pneumatiques Résistance électrique Méthode d'essai

More information

OPTIMASS 2000 Technical Datasheet

OPTIMASS 2000 Technical Datasheet OPTIMASS 2000 Technical Datasheet Sensor for bulk mass flow Large diameter for bulk measurement and custody transfer of liquids and gases Stainless Steel measuring tubes (NACE Compliant) Modular electronics

More information

EC Declaration of Conformity, EC DoC. ew Graze QLX Powercore ew Graze EC Powercore ecolor Graze QLX Powercore. ecolor Graze EC Powercore

EC Declaration of Conformity, EC DoC. ew Graze QLX Powercore ew Graze EC Powercore ecolor Graze QLX Powercore. ecolor Graze EC Powercore Declaration of Conformity Philips Color Kinetics 3 Burlington Woods Drive Burlington, MA 01803, USA Year in which CE Mark was first affixed: 2012 Declare responsibility for the product(s): Product Range:

More information

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle Thyristor power controller TE10A Burst-firing Single-cycle Advanced Single-cycle Control of short-wave infrared elements and loads of constant resistance up to 20kW User Manual Copyright Eurotherm Automation

More information

BATCHFLUX 5500 C Technical Datasheet

BATCHFLUX 5500 C Technical Datasheet BATCHFLUX 5500 C Technical Datasheet Electromagnetic flowmeter for volumetric filling machines High-stability zirconium oxide measuring tube Extreme long-term stability Most compact and lightweight design

More information

ToughPIX 2300XP Series INSTRUCTIONS FOR SAFE OPERATION

ToughPIX 2300XP Series INSTRUCTIONS FOR SAFE OPERATION ToughPIX 2300XP Series INSTRUCTIONS FOR SAFE OPERATION II 2 G I M2 Ref. ID 2310, Rev. A Email: sales@cord-ex.com www.cordexinstruments.com CONTENTS 1. READ THIS FIRST 1. READ THIS FIRST 1 Liability 1 Trademark

More information

Floodlight Range Installation Guide

Floodlight Range Installation Guide SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected

More information

Pressure Sensors. for liquid and gaseous media

Pressure Sensors. for liquid and gaseous media 1 909 1909P01 Pressure Sensors for liquid and gaseous media QBE2002-P QBE2102-P Piezo-resistive measuring system DC 0...10 V or DC 4 20 ma output signal Measurement unaffected by changes in temperature

More information

User Guide AMF Floor / Portrait Adaptor

User Guide AMF Floor / Portrait Adaptor User Guide AMF100200 Floor / Portrait Adaptor SAFTEY INFORMATION These instructions should be handed over to the person carrying out the installation. 1. Only a qualified technician should carry out installation

More information

AEROSTAT HP-N-Ex Ionising Air Blower

AEROSTAT HP-N-Ex Ionising Air Blower SIMCO (Nederland) B.V. Postbus 71 NL-7240 AB Lochem Telefoon + 31-(0)573-288333 Telefax + 31-(0)573-257319 E-mail general@simco-ion.nl Internet http://www.simco-ion.nl Traderegister Apeldoorn No. 08046136

More information

AXIAL FANS Axis / Tubo OPERATION MANUAL

AXIAL FANS Axis / Tubo OPERATION MANUAL TUBO-M AXIS-QA AXIS-Q AXIS-QR AXIS-F AXIS-QRA AXIAL FANS Axis / Tubo OPERATION MANUAL Axis / Tubo www.blaubergventilatoren.de CONTENT 3 Introduction 3 General 3 Safety rules 3 Transport and storage requirements

More information

OPTIGAS 4010C Technical Datasheet

OPTIGAS 4010C Technical Datasheet OPTIGAS 4010C Technical Datasheet Sensor for gas dispenser applications Compact design for easy istallation High accuracy with wide measuring range Designed to fit existing dispensers The documentation

More information

Waterjet cutting is one of the most versatile cutting processes around.

Waterjet cutting is one of the most versatile cutting processes around. Techserv Cutting Systems Ltd Huddersfield Road Mirfield West Yorkshire England WF14 9DL tel:+44(0)1924 460456 fax:+44(0)1924 458630 e-mail: info@techserv.co.uk www.techserv.co.uk Waterjet cutting is one

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD ISO 16924 First edition 2016-12-01 Natural gas fuelling stations LNG stations for fuelling vehicles Stations-service de gaz naturel Stations GNL pour le ravitaillement de véhicules

More information

Installation, Operating & Maintenance Instructions. Norbro J-Switch FM 00707

Installation, Operating & Maintenance Instructions. Norbro J-Switch FM 00707 Installation, Operating & Maintenance Instructions Norbro J-Switch as FM 00707 INTRODUCTION The J-Switch is a control package incorporating switches, sensors or pneumatic valves for actuator end of travel

More information

PREFACE. Thank you for your purchase of the Böhler-AG Petrol Generator.

PREFACE. Thank you for your purchase of the Böhler-AG Petrol Generator. 1 PREFACE Thank you for your purchase of the Böhler-AG Petrol Generator. The Böhler-AG Petrol Generator is a Powerful, low fuel consumption, low pollution, low noise, simple to operate and easy to move.

More information

Automated and precise static load testing with absolute control and high performance

Automated and precise static load testing with absolute control and high performance Automated and precise static load testing with absolute control and high performance ATLAS Pile Testing systems presents the Titan 650, for automated, remote controlled static load testing of piles and

More information

Turbocharger / A100-L Original assembly instructions English

Turbocharger / A100-L Original assembly instructions English Assembly Instructions Turbocharger / A100-L Original assembly instructions English This document is valid for the A100-L series: A165-L, A170-L, A175-L, A180-L, A185-L, A190-L Purpose The assembly instructions

More information

Ultra High Purity Transducer, Ex na nl Models WU-20, WU-25 and WU-26

Ultra High Purity Transducer, Ex na nl Models WU-20, WU-25 and WU-26 Electronic Pressure Measurement Ultra High Purity Transducer, Ex na nl Models WU-20, WU-25 and WU-26 WIKA Datasheet WU-2X Applications Gas panels for OEM tools Semiconductor, flat panel display and photovoltaic

More information

OPTIGAS 4010C Technical Datasheet

OPTIGAS 4010C Technical Datasheet OPTIGAS 4010C Technical Datasheet Sensor for gas dispenser applications Compact design for easy istallation High accuracy with wide measuring range Designed to fit existing dispensers The documentation

More information

Operation Manual FLG-G5 Transtech Gravity Spray Gun SB-E ISS.05

Operation Manual FLG-G5 Transtech Gravity Spray Gun SB-E ISS.05 Operation Manual FLG-G5 Transtech Gravity Spray Gun SB-E-2-790 ISS.05 Operation Manual FLG5 Gravity-feed Spray Gun Important Read and follow all instructions and Safety Precautions before using this equipment

More information

EC225 Power Control System

EC225 Power Control System 1 Key Features 200W (~16A) combined Power Converter / Battery Charger - Converts the 230V mains supply into 12v DC power to run the leisure equipment and charge the battery using an intelligent two-stage

More information

1. TECHNICAL SPECIFICATIONS & OPERATION MANUAL

1. TECHNICAL SPECIFICATIONS & OPERATION MANUAL 1. TECHNICAL SPECIFICATIONS & OPERATION MANUAL The GAV solenoid operated gas admission valve is designed for use on four-cycle turbo-rcharged engines to govern the required amount of fuel admitted into

More information

Operation Manual for. HC16 Three-Axis Helmholtz Coil

Operation Manual for. HC16 Three-Axis Helmholtz Coil Operation Manual for HC16 Three-Axis Helmholtz Coil Table of Contents 1. About this Manual 3 1.1. Symbols Glossary 3 2. Safe Use 4 3. Introduction 4 3.1. HC16 Helmholtz Coil Assembly Features 5 4. HC16

More information

Technical Data FUEL CONTROL SYSTEM TANK GAUGE INTERFACE KIT. Applies to the following models only: - FC.TGE - FC.OCIO

Technical Data FUEL CONTROL SYSTEM TANK GAUGE INTERFACE KIT. Applies to the following models only: - FC.TGE - FC.OCIO Technical Data FUEL CONTROL SYSTEM TANK GAUGE INTERFACE KIT Applies to the following models only: - FC.TGE - FC.OCIO Please read carefully before commencing installation Registered Office: HYTEK (GB) LIMITED,

More information

Special Radial piston pumps Type SRK-ATEX

Special Radial piston pumps Type SRK-ATEX Special Radial piston pumps Type SRK-ATEX Features High volumetric efficiency Self-priming and venting Low pulsation Low noise level Design Radial piston pump of modular design With valve controlled pump

More information

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35 Electrical temperature measurement Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35 WIKA data sheet TE 60.03 for further approvals see page 7 Applications Machinery,

More information

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013) Adam Equipment DUNE DCT SERIES (P.N. 9384, Revision B2, June 2013) Adam Equipment Company 2013 Easy Reference: Model name of the scale: Serial number of the unit: Software revision number (Displayed when

More information

SENSOR MUT2200EL. Electromagnetic flowmeter. The electromagnetic flowmeter for all applications DS100-6-ENG

SENSOR MUT2200EL. Electromagnetic flowmeter. The electromagnetic flowmeter for all applications DS100-6-ENG SENSOR MUT2200EL Electromagnetic flowmeter The electromagnetic flowmeter for all applications DS100-6-ENG Sensor MUT2200EL MUT2200EL sensors represent the state of the art of Euromag International production

More information

Differential Pressure Sensors

Differential Pressure Sensors 1 920 1920P01 Differential Pressure Sensors for neutral and mildly corrosive liquids and gases QBE63-DP Differential pressure sensor, suitable for gases and liquids, for the measurement of positive and

More information

DigiTemp. Digital Thermometer

DigiTemp. Digital Thermometer DigiTemp R Digital Thermometer (Standard Version) Page 1 The DigiTemp battery-powered digital thermometer is designed to suit a wide range of industrial applications which demand accurate measurement of

More information

Multi Bale Handler. No Instruction Manual & Operating Guide

Multi Bale Handler. No Instruction Manual & Operating Guide Multi Bale Handler No. 1412 Instruction Manual & Operating Guide EC Declaration of Conformity in accordance with BS EN ISO/IEC 17050-1:2004 David Ritchie (Implements) Ltd., Carseview Road, Forfar, Scotland

More information

MAS, MAS.1 weighing modules

MAS, MAS.1 weighing modules MAS, MAS.1 weighing modules Series of professional electromagnetic modules of high resolution ensures highly precise and fast measurement in laboratory. MAS.1.Y MAS.1.R MAS.1 MAS Features High Resolution

More information

HC2 Three-Axis Helmholtz Coil

HC2 Three-Axis Helmholtz Coil INNOVATION IN MAGNETICS Operation Manual for HC2 Three-Axis Helmholtz Coil www.bartington.com Table of Contents 1. About this Manual 3 1.1. Symbols Glossary 3 2. Safe Use 4 3. Introduction 4 4. HC2 Helmholtz

More information

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology VALVE CONTROLLERS Controllers for Dust Extraction 2010 Technology / 2011 Valve controllers for all cases HESCH has the skills and technology to tackle any control task for dedusting of filter and dust

More information

Type A-10 General Purpose Pressure Transmitter

Type A-10 General Purpose Pressure Transmitter General Purpose TRONIC > General Purpose > A-10 Type A-10 General Purpose Pressure Transmitter Standard Features Signal output: 4-20 ma 2-wire or 0-10 V 3-wire Supply voltage: 8-30 DC (14-30 VDC) Process

More information

M200. Battery Charger. For lead-acid batteries. User Manual and Guide to professional charging of starter and deep cycle batteries.

M200. Battery Charger. For lead-acid batteries. User Manual and Guide to professional charging of starter and deep cycle batteries. M200 Battery Charger For lead-acid batteries User Manual and Guide to professional charging of starter and deep cycle batteries. GB 20010739C M200 Manual 001.indd 1 2011-06-20 12:33:19 INTRODUCTION Congratulations

More information

Differential Pressure Sensors

Differential Pressure Sensors 1 910 1910P01 Differential Pressure Sensors for air or nonaggressive gases QBM66... Pressure-linear characteristic with selectable pressure measuring range Operating voltage AC 24 V or DC 13.5...33 V Output

More information

Battery Charger XT EXTENDED. For lead-acid batteries. User Manual and Guide to professional charging of starter and deep cycle batteries.

Battery Charger XT EXTENDED. For lead-acid batteries. User Manual and Guide to professional charging of starter and deep cycle batteries. Battery Charger XT 14000 EXTENDED For lead-acid batteries User Manual and Guide to professional charging of starter and deep cycle batteries. INTRODUCTION Congratulations on purchasing your new CTEK professional

More information

OPTIMASS 3000 Technical Datasheet

OPTIMASS 3000 Technical Datasheet OPTIMASS 3000 Technical Datasheet Sensor for mass flow First choice for low flow applications Certified secondary pressure containment A common footprint for all three sizes, in Hastelloy or Stainless

More information

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module Electrical temperature measurement Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module WIKA data sheet TE 60.17 for further approvals see page 6 Applications

More information

MONITORED HYDRAULIC VALVE SYSTEMS

MONITORED HYDRAULIC VALVE SYSTEMS Nov 2009 MONITORED HYDRAULIC VALVE SYSTEMS HBV Cetop 7&8 Series. Patented Technology SUITABLE FOR RISK CATEGORY 4 APPLICATIONS As per EN 954-1 & AS4024.1 (2006) Fluidsentry Pty Ltd P.O.Box 8135 (1 / 32-34Frankston

More information

Electric Hi Lo Screen lift Trolley Mount 8960

Electric Hi Lo Screen lift Trolley Mount 8960 Electric Hi Lo Screen lift 750 - Trolley Mount 8960 - Max Capacity 100kg - Min Capacity 5kg - Screens upto 86 WARNING! THIS IS NOT A TOY! WARNING! CHILDREN SHOULD NOT OPERATE LIFT OR HAVE ACCESS TO THE

More information

IQL Helios Area-/Streetlight. User Manual

IQL Helios Area-/Streetlight. User Manual Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 4. Product Description... 5 5. Specifications... 6 5.1 General... 6 5.2 Dimensions... 6 6. Installation...

More information

тел.: +375(1771) e mail: Fuel level sensors eurosens Dominator

тел.: +375(1771) e mail: Fuel level sensors eurosens Dominator тел.: +375(1771)7 13 00 e mail: office@mechatronics.by Fuel level sensors eurosens Dominator Application The devices are used in vehicle tanks and stationary capacities for fuel level measurement. The

More information

User Manual. Studio Rail. Size Version

User Manual. Studio Rail. Size Version User Manual Studio Rail Size 60 Version 10.1 Contents Contents: Introduction... 2 Exclusion of Liability... 2 Safety Instructions... 2 Operating Data...3-8 1. Selecting the correct carriage...3-5 2. Mounting

More information

Instruction Manual. ThinkTop D30 ESE02248-EN Patented Sensor System Registered Design Registered Trademark. Original manual _1

Instruction Manual. ThinkTop D30 ESE02248-EN Patented Sensor System Registered Design Registered Trademark. Original manual _1 Instruction Manual ThinkTop D30 2064-0000_1 Patented Sensor System Registered Design Registered Trademark ESE02248-EN3 2014-12 Original manual Table of contents The information herein is correct at the

More information

FIRST FOR PORTABLE PARTICLE COUNTING

FIRST FOR PORTABLE PARTICLE COUNTING FIRST FOR PORTABLE PARTICLE COUNTING FS9V2-RH & FS9V2-RH-HP - particulate and relative humidity monitoring The FS9V2-RH Particle Pal displays live cleanliness readings for particulate (ISO/NAS/SAE) and

More information

Adam Equipment QT SERIES. ADAM EQUIPMENT CO. LTD. pn Rev. D1, July 2002

Adam Equipment QT SERIES. ADAM EQUIPMENT CO. LTD. pn Rev. D1, July 2002 Adam Equipment QT SERIES ADAM EQUIPMENT CO. LTD. pn. 3938 Rev. D1, July 2002 Adam Equipment Co. Ltd. 2002 Adam Equipment Co. Ltd. 2002 FEATURES Auto shut off Auto zero tracking Auto backlight (optional)

More information

Pressure transducer DMU 01K Compact version

Pressure transducer DMU 01K Compact version Pressure transducer DMU 01K Compact version Dimensions (in mm) Wiring diagram 8 Application Special OEM unit. For electronic pressure measurement in industrial or HVAC applications (such as hydraulic,

More information

SRS SEALED ROTARY SENSORS

SRS SEALED ROTARY SENSORS SRS SEALED ROTARY SENSORS Innovation In Motion INNOVATION IN MOTION Penny+Giles SRS280 sealed rotary sensors and SRS880 submersible rotary sensors have been specially developed to provide maximum performance

More information

WPS500X. 500 psi / 34.5 bar Automotive Pressure Transducer. User s Guide

WPS500X. 500 psi / 34.5 bar Automotive Pressure Transducer. User s Guide WPS500X 500 psi / 34.5 bar Automotive Pressure Transducer User s Guide This accessory complies with the following standards: Electromagnetic Compatibility (EMC) Directive 2004/108/EC FCC Part 15 Pressure

More information

NEW AND EXTREME HIGH QUALITY CABLE GUARDS RED LINE USE WITH HIGH VOLUME VEHICULAR TRAFFIC

NEW AND EXTREME HIGH QUALITY CABLE GUARDS RED LINE USE WITH HIGH VOLUME VEHICULAR TRAFFIC NEW AND EXTREME HIGH QUALITY CABLE GUARDS MANUFACTURED IN UK RED LINE USE WITH HIGH VOLUME VEHICULAR TRAFFIC BLACK LINE USE WITH LOW VOLUME VEHICULAR AND ALL PEDESTRIAN TRAFFIC RED FLOOR 3 SLOT AND 5 SLOT

More information

INSERTION flow sensor for continuous flow measurement

INSERTION flow sensor for continuous flow measurement INSERTION flow sensor for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN)

More information

Portable Fuel Dispensing Equipment

Portable Fuel Dispensing Equipment Portable Fuel Dispensing Equipment (Model 107 Fuel Conditioning Cart) (Model 106 Fuel Service Cart) Webber EMI offers a full line of fuel dispensing & handling equipment, from fuel conditioning drum carts,

More information

Electric Fuel Pump FPM

Electric Fuel Pump FPM INSTRUCTION MANUAL Electric Fuel Pump FPM S1590, Rev B LISTED MOTOR FPM-12, FPM-12/HF, FPM-24, FPM-115, FPM-220 Congratulations on purchase of this World Class Electric Fuel Pump! Pump Outlet Elbow Nozzle

More information

Smart Pressure Transmitter

Smart Pressure Transmitter DOC. NO.: C3500L-E16A Smart Pressure Transmitter with Diaphragm Seal MODEL APT3500L 298-29, GONDAN-RO, GUNPO-SI, GYEONGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200 E-mail: autrol@duon.co.kr,

More information

OPTISWITCH 6500 C Technical Datasheet

OPTISWITCH 6500 C Technical Datasheet OPTISWITCH 6500 C Technical Datasheet Microwave Level Switch for advanced hygienic applications Optimised sensor geometry, easy to clean Measures products with dielectric constant > 1.5 Maintenance-free

More information

Differential Pressure Switch QBM81-

Differential Pressure Switch QBM81- s 1 552 Differential Pressure Switch QBM81- for air and nonaggressive gases For ventilation and air conditioning plants To monitor air filters, air flow, fan belts To monitor pressure in clean rooms, kitchens

More information

RF DIRECTIONAL THRULINE POWER SENSOR MODEL 5010

RF DIRECTIONAL THRULINE POWER SENSOR MODEL 5010 INSTRUCTION SHEET RF DIRECTIONAL THRULINE POWER SENSOR MODEL 5010 Copyright 2003 by Bird Electronic Corporation Instruction Book Part Number 920-5010 Rev. E Connecting Sensor CAUTION Do not connect or

More information

TB SERIES PUMPS TBS OPERATION & PARTS MANUAL

TB SERIES PUMPS TBS OPERATION & PARTS MANUAL TB SERIES PUMPS TBS OPERATION & PARTS MANUAL EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable health and safety requirements

More information

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE 2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE For Diaphragm Dosing Pumps FEM 1.02_.55 / FEM 1.09_.55 Controller board package, without pump: ID 160536 Operating and Installation Manual It is important to

More information

TORRIX Magnetostrictive level sensor

TORRIX Magnetostrictive level sensor TORRIX Magnetostrictive level sensor Precision Versatility Security Sensors & Systems Worldwide: www.fafnir.com FAFNIR Quality and Satisfaction Company: Based in Hamburg, Germany, FAFNIR GmbH has over

More information

Electric Fuel Pump FPM

Electric Fuel Pump FPM INSTRUCTION MANUAL Electric Fuel Pump FPM S1590, Rev B LISTED MOTOR FPM-12, FPM-24, FPM-115, FPM-220 Congratulations on purchase of this World Class Electric Fuel Pump! Elbow This is an Electric Fuel Pump.

More information

WPS600. Hydraulic Pressure Transducer. User s Guide. 600 bar 60 MPa 8700 psi

WPS600. Hydraulic Pressure Transducer. User s Guide. 600 bar 60 MPa 8700 psi WPS600 Hydraulic Pressure Transducer User s Guide This accessory complies with the following standards: Electromagnetic Compatibility (EMC) Directive 2004/108/EC FCC Part 15 Pressure Equipment Directive

More information

Electronic Limit Switch Type

Electronic Limit Switch Type Electronic Limit Switch Type 3738-20 with optional solenoid valve for on/off rotary actuators Application Electronic limit switch for on/off applications to indicate the end position of rotary actuators.

More information

TBP SERIES PUMPS OPERATION & PARTS MANUAL

TBP SERIES PUMPS OPERATION & PARTS MANUAL TBP SERIES PUMPS OPERATION & PARTS MANUAL EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable health and safety requirements

More information

Spare Parts List Filter NFD Change-Over Version

Spare Parts List Filter NFD Change-Over Version Spare Parts List Filter Change-Over Version up to 1600 l/min, up to 5 bar 1340 640 540 7840 10440 1. MAINTENANCE GENERAL Please follow the maintenance instructions! 1. INSTALLATION Before fitting the filter

More information

OPTISWITCH 6500 C Technical Datasheet

OPTISWITCH 6500 C Technical Datasheet OPTISWITCH 6500 C Technical Datasheet Switch for level detection and dry-run protection Optimised sensor geometry, easy to clean Measures products with dielectric constant > 1.5 Maintenance-free KROHNE

More information

Mod: KLD6-12/35XLAS-N

Mod: KLD6-12/35XLAS-N 12/2011 Mod: KLD6-12/35XLAS-N Production code: 1914070 INSTRUCTION MANUAL LOGIC LINE PLUS HOOD Reseller Stamp for Warranty Dear customer, Above all, thank you for choosing our product and we would like

More information

ISO INTERNATIONAL STANDARD. Hoists for the transfer of disabled persons Requirements and test methods

ISO INTERNATIONAL STANDARD. Hoists for the transfer of disabled persons Requirements and test methods INTERNATIONAL STANDARD ISO 10535 Second edition 2006-12-15 Hoists for the transfer of disabled persons Requirements and test methods Lève-personnes pour transférer des personnes handicapées Exigences et

More information

User Instruction Manual Oxford Classic Digital Weigh Scale. To avoid injury, read user manual prior to use.

User Instruction Manual Oxford Classic Digital Weigh Scale. To avoid injury, read user manual prior to use. User Instruction Manual Oxford Classic Digital To avoid injury, read user manual prior to use. Oxford English Contents 1. Introduction: About Your Scale... 3 2. Assembly and Commissioning Instructions...

More information

ELEMENT. Product family datasheet. Constant Voltage Non dimmable

ELEMENT. Product family datasheet. Constant Voltage Non dimmable ELEMENT Constant Voltage Non dimmable Areas of application _ Suitable for luminaires of protection class II _ Decorative lighting in hospitality, restaurants and Shops _ Shelf lighting for shops _ Cove

More information

A brief guide for identification of non-compliant construction machinery. Is this. Compactor / Roller compliant with European legislation?

A brief guide for identification of non-compliant construction machinery. Is this. Compactor / Roller compliant with European legislation? A brief guide for identification of non-compliant construction machinery Is this Compactor / Roller compliant with European legislation? Introduction Construction equipment placed on the EU market for

More information

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05 DL 0 Battery Powered for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless

More information

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter. TEMATEC GmbH Postal address:: Postbox 6 House address Löhestr. 7 5759 Hennef 577 Hennef Fon (+49) 0 4-87 0-0 Fax (+49) 0 4-87 0-0 http: // www.tematec.de e-mail: team@ tematec.de TEMATEC GmbH Data Sheet

More information

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding Electrical temperature measurement Resistance thermometer For sanitary applications Model TR22-B, for orbital welding WIKA data sheet TE 60.23 for further approvals see page 11 Applications Sanitary applications

More information

EC Type-Approval Certificate UK 2655 Revision 2

EC Type-Approval Certificate UK 2655 Revision 2 UK 2655 V(0)a EC Type-Approval Certificate UK 2655 Revision 2 Issued by: National Measurement Office Notified Body Number 0126 In accordance with the requirements of the Non-automatic Weighing Instruments

More information

P r e s s u r e i S w i t c h e s V a c u u m i S w i t c h e s PressureiTransmitters

P r e s s u r e i S w i t c h e s V a c u u m i S w i t c h e s PressureiTransmitters P r e s s u r e i M o n i t o r i n g P r e s s u r e i S w i t c h e s V a c u u m i S w i t c h e s PressureiTransmitters TRADITION AND INNOVATION From a mechanical workshop to an international industrial

More information

Operating Instructions

Operating Instructions Resistance Thermometer Clamp-on technology for temperature measurement on pipes, Type Series GA261x Operating Instructions 1 General Information... 2 1.1 General Safety Notes... 2 1.2 Intended Use... 2

More information

BlueSwan Pipette Controller

BlueSwan Pipette Controller BlueSwan Pipette Controller BSST-0100 Operation Manual Ver. 1.0 Copyright 2016 Blue-Ray Biotech Corp. All Rights Reserved. Table of Contents 1. Safety Precautions... 1 2. General Description... 2 2.1

More information

Offshore Fuelling Systems

Offshore Fuelling Systems Offshore Fuelling Systems Fuel Management System Manufacturers, Aviation & Diesel Filtration Specialists Introduction: Eastern Petroleum Supplies Ltd are designers and manufacturers of a wide range of

More information