f-pod Intelligent Fuel Bowser
|
|
- Clementine Griffin
- 5 years ago
- Views:
Transcription
1 f-pod Intelligent Fuel Bowser The f-pod is a new generation of race fuel bowser which raises the bar in technology, safety, accuracy and ease of use. The f-pod has been developed with input of leading UK single seater teams with total success. The f-pod is housed in a transport ready, heavy duty flight case with easy accessible compartments for the control panel and hoses. The f-pod sits on low friction anti-static castors which are bonded to the bowser s electrical ground.
2 Intelligent Control The f-pod uses a 7 colour touch-screen PC loaded with our bespoke software to control the bowser s functions. Our inspired step by step, graphical instructions means refuelling errors are a thing of the past. It also has a multifunction control switch to select internal battery, external battery, via an Anderson plug and battery charger. CE marking dictated that the bowser must not be operated by mains electricity so the battery charger is external and can only be operated when the bowser is switched off. 2
3 The f-pod had a configurable Operator Present Push to Pump button which means it can be set so all pumping operations require the button to be held pushed until the procedure is complete. Releasing the button will pause the operation. Use of Push to Pump to move fuel from the bowser to a fuel drum is compulsory. An Emergency Stop Button is standard on all machines. There is a USB socket included to download totals information when the totals option has been purchased. The control panel is part of an IP65, sealed electrical box which contains all of the electrical components and battery to help eliminate spark risk. All connection cables pass into the box though ATEX approved cable glands. The fuel tank is a fabricated from 3mm thick aluminium sheet, TIG welded together and pressure tested. All unions are -12 AN fittings. The tank bottom is tapered towards the outlet and drain plug to ensure it fully drains. The tank is bolted to a heavy duty loadcell and frame with over load stops and transport lock. The loadcell is 100% over-rated for reliability. The tank is connected, by high quality Aeroquip Startlite hose to a high volume explosion proof pump / motor assembly which includes its own internal filter and over-pressure valve. The pump then outputs via a 2 metre hose terminating in a -12 Staubli dry break connector. An anti-siphon valve assembly can be optioned, which connects to the output of the pump to prevent siphoning in either direction if the hoses are left connected to the car or fuel drum for any period of time. 3
4 A vent hose is connected to the top of the fuel tank via a bulkhead fitting in the hose compartment to a 2 metre hose terminating in a -8 Staubli dry break connector. CE demanded that there could be no open vent on the bowser, so the f-pod will breathe through the race cars own vent during refuelling or through the drum adaptors flame trap when connected to a fuel drum. When the bowser hoses are disconnected the system is completely sealed with no vapour loss. There is also an anti-static bonding cable from the bowser, which must be connected to the car or fuel drum before the hoses are connected. This again, is to reduce possible spark risk The f-pod software utilises special routines to check the state of the fuel hose at anytime. We can then compensate for a full or empty hose ensuring the accuracy of all fuel transfer totals 4
5 The software also monitors the level of fuel in the tank at any time both in kg and by percentage of capacity. The tank capacity can be factory set to any specific weight within its dimensional volume, allowing for an expansion factor with reference to the fuels specific gravity. This means it is impossible to overfill the tank, and strict regulation of capacity can be controlled. Fuel can be transferred to within a repeatable accuracy of 100g Optional extras Multiuser / Totals With this option, the f-pod can be used to fuel several different cars or drivers and keep an accurate record of all fuel transactions in and out of each particular car. This information is instantly viewable on the screen and is also downloadable via the USB port as a CVL file for further analysis. It will also record all fuel added and drawn from the bowser to and from fuel drums. 5
6 ATC Automatic Track Compensation Weight changes slightly depending where you are located in the world. Most weighing machines are calibrated in the region that they are going to be used so this error is never normally seen, but in motorsport, teams can be travelling to anywhere in the world, taking all their equipment with them. A bowser calibrated in Oxford will not read the same weight in Sao Paulo. 6
7 To solve this, the f-pod can be loaded with our unique ATC or Automatic Track Compensation software which will automatically correct this error when you select your current circuit location from the resident list. Anti-siphon An anti-siphon valve assembly can be optioned, which connects to the output of the pump to prevent siphoning in either direction if the hoses are left connected to the car or fuel drum for any period of time. Other Fuels The f-pod can be made to handle other fuels not included in the general specification. 7
8 General Specification f-pod Lite General Construction: Dimensions: Gross Weight Empty: Power Source: Max Current Draw: Max Power: Suitable Fuels: Ambient Temperature: Maximum Use Per Day: IP Rating: Noise: Vibration: Aluminium & Ply Flightcase Construction Mounted on Antistatic Castors. IP65 Sealed Steel Electrical Cabinet. 640w x 680d x 940h mm 91kg Internal 12Vdc 33Ahr AGM Battery 15Adc 180W Petrol up to 15% alcohol blends (E15), Diesel up to 20% bio-diesel blends (B20), and Kerosene. For other application contact EEC Performance Systems for advice degree C 3 Hours overall Control Panel IP65 Less than 70db(A) Does Not Exceed 2.5m/s² 8
9 We: Essential Equipment Consortium Ltd EC Declaration of Conformity In accordance with BS EN ISO/IEC :2010 Of: Unit 4, Maizefield, Hinckley Fields Ind Est, Hinckley, Leics. LE10 1YK. United Kingdom declare that: Equipment: Intelligent Race Fuel Bowser Model name/number: f-pod Lite FPL080 in accordance with the following Directives: 2004/108/EC 2006/42/EC 2002/95/EC Conforms with the essential performance requirements of the Electromagnetic Compatibility Directive and its amending directives Conforms with the essential health and safety requirements of the Machinery Directive and its amending directives Conforms with the requirements of the RoHS Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment has been designed and manufactured to the following specifications: EN ISO 12100:2010 Safety of machinery - General principles for design - Risk assessment and risk reduction EN :2011 Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology EN :2006 Electrical equipment for measurement, control and laboratory use - EMC requirements -- Part 1: General requirements EN :2006 Electromagnetic compatibility (EMC) -- Part 3-2: Limits - Limits for harmonic current emissions (equipment input current <= 16 A per phase) EN :2008 Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection I hereby declare that the equipment named above has been tested and found to comply with the relevant sections of the above referenced specifications. The unit complies with all relevant essential requirements of the Directives. Signed by:... Name:... Position:... Done at:... On:... This declaration of conformity is issued under the sole responsibility of Essential Equipment Consortium Ltd 9
10 Essential Equipment Consortium Ltd Unit 4, Maizefield, Hinckley Fields Ind Est, Hinckley, Leics, LE10 1YF Telephone: Facsimile:
Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter
Product Data Sheet February 2015 IP119, Rev CA Displacer Level Transmitter Level, contents or interface measurement transmitter Direct or external chamber mounting 4 20 ma HART output ATEX Intrinsically
More informationSITRANS P measuring instruments for pressure
Overview Application The pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials guarantees compliance with
More informationDITCH KING & DITCH BOSS. Tractor Mounted Digger. Operation & Parts Manual
Publication 106 (Issue 4) October 1984 Part No. 7118850 Revision: January 1993 DITCH KING & DITCH BOSS Tractor Mounted Digger Operation & Parts Manual IMPORTANT VERIFICATION OF WARRANTY REGISTRATION DEALER
More informationc-go 24V/6A 24V/8A 24V/12A
c-go 24V/6A 24V/8A 24V/12A Battery charger GB Instruction manual 1 Index 1. Product description... 2 2. Safety advices... 3 3. Quick start guide... 4 4. Operation... 4 5. Problem solving... 6 6. Specifications...
More informationPressure Transmitters
Transmitters Wetted parts are all made of stainless steel for high resistance to chemicals Stainless steel diaphragm welded with casing No seals and thus low leakage rate even with difficult gases High
More informationC:\Users\Steen Lauritzen\Dropbox\CTS - Citrotek\English quotation text\pharma\cp+10_1200 eng.doc
C:\Users\Steen Lauritzen\Dropbox\CTS - Citrotek\English quotation text\pharma\cp+10_1200 eng.doc 13.10.2017-1 - CTS - Climatic Test Cabinet Type CP+10/1200 C:\Users\Steen Lauritzen\Dropbox\CTS - Citrotek\English
More informationEC400 Power Control System
1 Introduction This section of the handbook will guide you through the operation of the electrical system. Further technical details are contained in section 3 or in the supporting technical manual available
More informationMulti-Mover Charger for model L25
Multi-Mover Charger for model L25 Important safety instruction. Keep these instructions. This manual contains important instructions for the safety of the user and the operation of the device. 1. SYMBOLS
More informationCompact Scales. Software Revision V1.25 & above
Compact Scales Software Revision V1.25 & above 2016 1 Easy Reference: Model name of the scale: Serial number of the unit: Software revision number (Displayed when power is first turned on): Date of Purchase:
More informationZone 1 Linear Range - Installation Guide
Zone 1 Linear Range - Installation Guide CML14ATEX3119 & IEC Ex CML15.0001 This installation guide provides instructions for installing SPARTAN series of explosion protected Zone 1 Linear luminaires. Text
More informationExplosion-Protected Pressure Switches
Explosion-Protected Pressure Switches To new ATEX Standard TECHNICAL DATA 0165 0340 0341 Degree of protection: IP 65 ATEX protection zone: 1 22 22 Switching power: 1 A / 250 VAC 0.25 A / 250 VDC 2 A /
More informationOperating and Installation Instructions Diaphragm Vacuum Pumps and Compressors
Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Type range: UN813.3ANI UN813.4ANI UN813.3ANDCB UN813.4ANDCB UN813.5ANI Fig. 1: UN813.3ANI Fig. 2: UN813.4ANI You have selected
More informationEC200 ELECTRONIC CONTROL SYSTEM
1 INTRODUCING THE EC200 ELECTRONIC CONTROL SYSTEM With the use of new technology and an innovative approach to user interfacing, the EC200 Power Control System provides a complete control solution for
More information2018 CAMS MANUAL OF MOTOR SPORT
2018 CAMS MANUAL OF MOTOR SPORT GENERAL REQUIREMENTS OF AUTOMOBILES Schedule N Fuel Tanks and Refueling CONFEDERATION OF AUSTRALIAN MOTOR SPORT WWW.CAMS.COM.AU Modified Article Date of Application Date
More informationWOOOM INSTRUCTION MANUAL
WOOOM INSTRUCTION MANUAL Thank you very much for choosing the Wooom chair from Klöber! Please read this instruction manual carefully before using the chair. Please download the Wooom app to your device
More informationDATUM ELECTRONICS RS425 NON-CONTACT TORQUE TRANSDUCER PRODUCT OVERVIEW
DATUM ELECTRONICS LIMITED TELEPHONE: +44 (0) 1983 28 28 34 FAX: +44 (0) 1983 28 28 35 EMAIL: support@datum-electronics.co.uk WEB: www.datum-electronics.co.uk DATUM ELECTRONICS RS425 NON-CONTACT TORQUE
More informationDIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE
DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE W.CHRISTIE (INDUSTRIAL) LTD CHRISTIE HOUSE, MEADOWBANK ROAD, ROTHERHAM, SOUTH YORKSHIRE, S61 2NF, UK T: +44(0)1709 550088 F: +44(0)1709 550030 E:
More informationInstruction Manual. Back Pressure Regulator (Low Shear ¾ ) Bar Pilot Control
Back Pressure Regulator (Low Shear ¾ ) 107757 15.0 Bar 107758 - Pilot Control Product Description This Product is designed for use with: BPR - 107757, 107758, 107748, 107749, 107750, 107754, 107755, PRV22,
More informationISO INTERNATIONAL STANDARD. Tyres Electrical resistance Test method for measuring electrical resistance of tyres on a test rig
INTERNATIONAL STANDARD ISO 16392 First edition 2007-10-15 Tyres Electrical resistance Test method for measuring electrical resistance of tyres on a test rig Pneumatiques Résistance électrique Méthode d'essai
More informationOPTIMASS 2000 Technical Datasheet
OPTIMASS 2000 Technical Datasheet Sensor for bulk mass flow Large diameter for bulk measurement and custody transfer of liquids and gases Stainless Steel measuring tubes (NACE Compliant) Modular electronics
More informationEC Declaration of Conformity, EC DoC. ew Graze QLX Powercore ew Graze EC Powercore ecolor Graze QLX Powercore. ecolor Graze EC Powercore
Declaration of Conformity Philips Color Kinetics 3 Burlington Woods Drive Burlington, MA 01803, USA Year in which CE Mark was first affixed: 2012 Declare responsibility for the product(s): Product Range:
More informationThyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle
Thyristor power controller TE10A Burst-firing Single-cycle Advanced Single-cycle Control of short-wave infrared elements and loads of constant resistance up to 20kW User Manual Copyright Eurotherm Automation
More informationBATCHFLUX 5500 C Technical Datasheet
BATCHFLUX 5500 C Technical Datasheet Electromagnetic flowmeter for volumetric filling machines High-stability zirconium oxide measuring tube Extreme long-term stability Most compact and lightweight design
More informationToughPIX 2300XP Series INSTRUCTIONS FOR SAFE OPERATION
ToughPIX 2300XP Series INSTRUCTIONS FOR SAFE OPERATION II 2 G I M2 Ref. ID 2310, Rev. A Email: sales@cord-ex.com www.cordexinstruments.com CONTENTS 1. READ THIS FIRST 1. READ THIS FIRST 1 Liability 1 Trademark
More informationFloodlight Range Installation Guide
SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected
More informationPressure Sensors. for liquid and gaseous media
1 909 1909P01 Pressure Sensors for liquid and gaseous media QBE2002-P QBE2102-P Piezo-resistive measuring system DC 0...10 V or DC 4 20 ma output signal Measurement unaffected by changes in temperature
More informationUser Guide AMF Floor / Portrait Adaptor
User Guide AMF100200 Floor / Portrait Adaptor SAFTEY INFORMATION These instructions should be handed over to the person carrying out the installation. 1. Only a qualified technician should carry out installation
More informationAEROSTAT HP-N-Ex Ionising Air Blower
SIMCO (Nederland) B.V. Postbus 71 NL-7240 AB Lochem Telefoon + 31-(0)573-288333 Telefax + 31-(0)573-257319 E-mail general@simco-ion.nl Internet http://www.simco-ion.nl Traderegister Apeldoorn No. 08046136
More informationAXIAL FANS Axis / Tubo OPERATION MANUAL
TUBO-M AXIS-QA AXIS-Q AXIS-QR AXIS-F AXIS-QRA AXIAL FANS Axis / Tubo OPERATION MANUAL Axis / Tubo www.blaubergventilatoren.de CONTENT 3 Introduction 3 General 3 Safety rules 3 Transport and storage requirements
More informationOPTIGAS 4010C Technical Datasheet
OPTIGAS 4010C Technical Datasheet Sensor for gas dispenser applications Compact design for easy istallation High accuracy with wide measuring range Designed to fit existing dispensers The documentation
More informationWaterjet cutting is one of the most versatile cutting processes around.
Techserv Cutting Systems Ltd Huddersfield Road Mirfield West Yorkshire England WF14 9DL tel:+44(0)1924 460456 fax:+44(0)1924 458630 e-mail: info@techserv.co.uk www.techserv.co.uk Waterjet cutting is one
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 16924 First edition 2016-12-01 Natural gas fuelling stations LNG stations for fuelling vehicles Stations-service de gaz naturel Stations GNL pour le ravitaillement de véhicules
More informationInstallation, Operating & Maintenance Instructions. Norbro J-Switch FM 00707
Installation, Operating & Maintenance Instructions Norbro J-Switch as FM 00707 INTRODUCTION The J-Switch is a control package incorporating switches, sensors or pneumatic valves for actuator end of travel
More informationPREFACE. Thank you for your purchase of the Böhler-AG Petrol Generator.
1 PREFACE Thank you for your purchase of the Böhler-AG Petrol Generator. The Böhler-AG Petrol Generator is a Powerful, low fuel consumption, low pollution, low noise, simple to operate and easy to move.
More informationAutomated and precise static load testing with absolute control and high performance
Automated and precise static load testing with absolute control and high performance ATLAS Pile Testing systems presents the Titan 650, for automated, remote controlled static load testing of piles and
More informationTurbocharger / A100-L Original assembly instructions English
Assembly Instructions Turbocharger / A100-L Original assembly instructions English This document is valid for the A100-L series: A165-L, A170-L, A175-L, A180-L, A185-L, A190-L Purpose The assembly instructions
More informationUltra High Purity Transducer, Ex na nl Models WU-20, WU-25 and WU-26
Electronic Pressure Measurement Ultra High Purity Transducer, Ex na nl Models WU-20, WU-25 and WU-26 WIKA Datasheet WU-2X Applications Gas panels for OEM tools Semiconductor, flat panel display and photovoltaic
More informationOPTIGAS 4010C Technical Datasheet
OPTIGAS 4010C Technical Datasheet Sensor for gas dispenser applications Compact design for easy istallation High accuracy with wide measuring range Designed to fit existing dispensers The documentation
More informationOperation Manual FLG-G5 Transtech Gravity Spray Gun SB-E ISS.05
Operation Manual FLG-G5 Transtech Gravity Spray Gun SB-E-2-790 ISS.05 Operation Manual FLG5 Gravity-feed Spray Gun Important Read and follow all instructions and Safety Precautions before using this equipment
More informationEC225 Power Control System
1 Key Features 200W (~16A) combined Power Converter / Battery Charger - Converts the 230V mains supply into 12v DC power to run the leisure equipment and charge the battery using an intelligent two-stage
More information1. TECHNICAL SPECIFICATIONS & OPERATION MANUAL
1. TECHNICAL SPECIFICATIONS & OPERATION MANUAL The GAV solenoid operated gas admission valve is designed for use on four-cycle turbo-rcharged engines to govern the required amount of fuel admitted into
More informationOperation Manual for. HC16 Three-Axis Helmholtz Coil
Operation Manual for HC16 Three-Axis Helmholtz Coil Table of Contents 1. About this Manual 3 1.1. Symbols Glossary 3 2. Safe Use 4 3. Introduction 4 3.1. HC16 Helmholtz Coil Assembly Features 5 4. HC16
More informationTechnical Data FUEL CONTROL SYSTEM TANK GAUGE INTERFACE KIT. Applies to the following models only: - FC.TGE - FC.OCIO
Technical Data FUEL CONTROL SYSTEM TANK GAUGE INTERFACE KIT Applies to the following models only: - FC.TGE - FC.OCIO Please read carefully before commencing installation Registered Office: HYTEK (GB) LIMITED,
More informationSpecial Radial piston pumps Type SRK-ATEX
Special Radial piston pumps Type SRK-ATEX Features High volumetric efficiency Self-priming and venting Low pulsation Low noise level Design Radial piston pump of modular design With valve controlled pump
More informationThreaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35
Electrical temperature measurement Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35 WIKA data sheet TE 60.03 for further approvals see page 7 Applications Machinery,
More informationAdam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)
Adam Equipment DUNE DCT SERIES (P.N. 9384, Revision B2, June 2013) Adam Equipment Company 2013 Easy Reference: Model name of the scale: Serial number of the unit: Software revision number (Displayed when
More informationSENSOR MUT2200EL. Electromagnetic flowmeter. The electromagnetic flowmeter for all applications DS100-6-ENG
SENSOR MUT2200EL Electromagnetic flowmeter The electromagnetic flowmeter for all applications DS100-6-ENG Sensor MUT2200EL MUT2200EL sensors represent the state of the art of Euromag International production
More informationDifferential Pressure Sensors
1 920 1920P01 Differential Pressure Sensors for neutral and mildly corrosive liquids and gases QBE63-DP Differential pressure sensor, suitable for gases and liquids, for the measurement of positive and
More informationDigiTemp. Digital Thermometer
DigiTemp R Digital Thermometer (Standard Version) Page 1 The DigiTemp battery-powered digital thermometer is designed to suit a wide range of industrial applications which demand accurate measurement of
More informationMulti Bale Handler. No Instruction Manual & Operating Guide
Multi Bale Handler No. 1412 Instruction Manual & Operating Guide EC Declaration of Conformity in accordance with BS EN ISO/IEC 17050-1:2004 David Ritchie (Implements) Ltd., Carseview Road, Forfar, Scotland
More informationMAS, MAS.1 weighing modules
MAS, MAS.1 weighing modules Series of professional electromagnetic modules of high resolution ensures highly precise and fast measurement in laboratory. MAS.1.Y MAS.1.R MAS.1 MAS Features High Resolution
More informationHC2 Three-Axis Helmholtz Coil
INNOVATION IN MAGNETICS Operation Manual for HC2 Three-Axis Helmholtz Coil www.bartington.com Table of Contents 1. About this Manual 3 1.1. Symbols Glossary 3 2. Safe Use 4 3. Introduction 4 4. HC2 Helmholtz
More informationVALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology
VALVE CONTROLLERS Controllers for Dust Extraction 2010 Technology / 2011 Valve controllers for all cases HESCH has the skills and technology to tackle any control task for dedusting of filter and dust
More informationType A-10 General Purpose Pressure Transmitter
General Purpose TRONIC > General Purpose > A-10 Type A-10 General Purpose Pressure Transmitter Standard Features Signal output: 4-20 ma 2-wire or 0-10 V 3-wire Supply voltage: 8-30 DC (14-30 VDC) Process
More informationM200. Battery Charger. For lead-acid batteries. User Manual and Guide to professional charging of starter and deep cycle batteries.
M200 Battery Charger For lead-acid batteries User Manual and Guide to professional charging of starter and deep cycle batteries. GB 20010739C M200 Manual 001.indd 1 2011-06-20 12:33:19 INTRODUCTION Congratulations
More informationDifferential Pressure Sensors
1 910 1910P01 Differential Pressure Sensors for air or nonaggressive gases QBM66... Pressure-linear characteristic with selectable pressure measuring range Operating voltage AC 24 V or DC 13.5...33 V Output
More informationBattery Charger XT EXTENDED. For lead-acid batteries. User Manual and Guide to professional charging of starter and deep cycle batteries.
Battery Charger XT 14000 EXTENDED For lead-acid batteries User Manual and Guide to professional charging of starter and deep cycle batteries. INTRODUCTION Congratulations on purchasing your new CTEK professional
More informationOPTIMASS 3000 Technical Datasheet
OPTIMASS 3000 Technical Datasheet Sensor for mass flow First choice for low flow applications Certified secondary pressure containment A common footprint for all three sizes, in Hastelloy or Stainless
More informationProcess resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module
Electrical temperature measurement Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module WIKA data sheet TE 60.17 for further approvals see page 6 Applications
More informationMONITORED HYDRAULIC VALVE SYSTEMS
Nov 2009 MONITORED HYDRAULIC VALVE SYSTEMS HBV Cetop 7&8 Series. Patented Technology SUITABLE FOR RISK CATEGORY 4 APPLICATIONS As per EN 954-1 & AS4024.1 (2006) Fluidsentry Pty Ltd P.O.Box 8135 (1 / 32-34Frankston
More informationElectric Hi Lo Screen lift Trolley Mount 8960
Electric Hi Lo Screen lift 750 - Trolley Mount 8960 - Max Capacity 100kg - Min Capacity 5kg - Screens upto 86 WARNING! THIS IS NOT A TOY! WARNING! CHILDREN SHOULD NOT OPERATE LIFT OR HAVE ACCESS TO THE
More informationIQL Helios Area-/Streetlight. User Manual
Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 4. Product Description... 5 5. Specifications... 6 5.1 General... 6 5.2 Dimensions... 6 6. Installation...
More informationтел.: +375(1771) e mail: Fuel level sensors eurosens Dominator
тел.: +375(1771)7 13 00 e mail: office@mechatronics.by Fuel level sensors eurosens Dominator Application The devices are used in vehicle tanks and stationary capacities for fuel level measurement. The
More informationUser Manual. Studio Rail. Size Version
User Manual Studio Rail Size 60 Version 10.1 Contents Contents: Introduction... 2 Exclusion of Liability... 2 Safety Instructions... 2 Operating Data...3-8 1. Selecting the correct carriage...3-5 2. Mounting
More informationInstruction Manual. ThinkTop D30 ESE02248-EN Patented Sensor System Registered Design Registered Trademark. Original manual _1
Instruction Manual ThinkTop D30 2064-0000_1 Patented Sensor System Registered Design Registered Trademark ESE02248-EN3 2014-12 Original manual Table of contents The information herein is correct at the
More informationFIRST FOR PORTABLE PARTICLE COUNTING
FIRST FOR PORTABLE PARTICLE COUNTING FS9V2-RH & FS9V2-RH-HP - particulate and relative humidity monitoring The FS9V2-RH Particle Pal displays live cleanliness readings for particulate (ISO/NAS/SAE) and
More informationAdam Equipment QT SERIES. ADAM EQUIPMENT CO. LTD. pn Rev. D1, July 2002
Adam Equipment QT SERIES ADAM EQUIPMENT CO. LTD. pn. 3938 Rev. D1, July 2002 Adam Equipment Co. Ltd. 2002 Adam Equipment Co. Ltd. 2002 FEATURES Auto shut off Auto zero tracking Auto backlight (optional)
More informationPressure transducer DMU 01K Compact version
Pressure transducer DMU 01K Compact version Dimensions (in mm) Wiring diagram 8 Application Special OEM unit. For electronic pressure measurement in industrial or HVAC applications (such as hydraulic,
More informationSRS SEALED ROTARY SENSORS
SRS SEALED ROTARY SENSORS Innovation In Motion INNOVATION IN MOTION Penny+Giles SRS280 sealed rotary sensors and SRS880 submersible rotary sensors have been specially developed to provide maximum performance
More informationWPS500X. 500 psi / 34.5 bar Automotive Pressure Transducer. User s Guide
WPS500X 500 psi / 34.5 bar Automotive Pressure Transducer User s Guide This accessory complies with the following standards: Electromagnetic Compatibility (EMC) Directive 2004/108/EC FCC Part 15 Pressure
More informationNEW AND EXTREME HIGH QUALITY CABLE GUARDS RED LINE USE WITH HIGH VOLUME VEHICULAR TRAFFIC
NEW AND EXTREME HIGH QUALITY CABLE GUARDS MANUFACTURED IN UK RED LINE USE WITH HIGH VOLUME VEHICULAR TRAFFIC BLACK LINE USE WITH LOW VOLUME VEHICULAR AND ALL PEDESTRIAN TRAFFIC RED FLOOR 3 SLOT AND 5 SLOT
More informationINSERTION flow sensor for continuous flow measurement
INSERTION flow sensor for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN)
More informationPortable Fuel Dispensing Equipment
Portable Fuel Dispensing Equipment (Model 107 Fuel Conditioning Cart) (Model 106 Fuel Service Cart) Webber EMI offers a full line of fuel dispensing & handling equipment, from fuel conditioning drum carts,
More informationElectric Fuel Pump FPM
INSTRUCTION MANUAL Electric Fuel Pump FPM S1590, Rev B LISTED MOTOR FPM-12, FPM-12/HF, FPM-24, FPM-115, FPM-220 Congratulations on purchase of this World Class Electric Fuel Pump! Pump Outlet Elbow Nozzle
More informationSmart Pressure Transmitter
DOC. NO.: C3500L-E16A Smart Pressure Transmitter with Diaphragm Seal MODEL APT3500L 298-29, GONDAN-RO, GUNPO-SI, GYEONGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200 E-mail: autrol@duon.co.kr,
More informationOPTISWITCH 6500 C Technical Datasheet
OPTISWITCH 6500 C Technical Datasheet Microwave Level Switch for advanced hygienic applications Optimised sensor geometry, easy to clean Measures products with dielectric constant > 1.5 Maintenance-free
More informationDifferential Pressure Switch QBM81-
s 1 552 Differential Pressure Switch QBM81- for air and nonaggressive gases For ventilation and air conditioning plants To monitor air filters, air flow, fan belts To monitor pressure in clean rooms, kitchens
More informationRF DIRECTIONAL THRULINE POWER SENSOR MODEL 5010
INSTRUCTION SHEET RF DIRECTIONAL THRULINE POWER SENSOR MODEL 5010 Copyright 2003 by Bird Electronic Corporation Instruction Book Part Number 920-5010 Rev. E Connecting Sensor CAUTION Do not connect or
More informationTB SERIES PUMPS TBS OPERATION & PARTS MANUAL
TB SERIES PUMPS TBS OPERATION & PARTS MANUAL EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable health and safety requirements
More information2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE
2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE For Diaphragm Dosing Pumps FEM 1.02_.55 / FEM 1.09_.55 Controller board package, without pump: ID 160536 Operating and Installation Manual It is important to
More informationTORRIX Magnetostrictive level sensor
TORRIX Magnetostrictive level sensor Precision Versatility Security Sensors & Systems Worldwide: www.fafnir.com FAFNIR Quality and Satisfaction Company: Based in Hamburg, Germany, FAFNIR GmbH has over
More informationElectric Fuel Pump FPM
INSTRUCTION MANUAL Electric Fuel Pump FPM S1590, Rev B LISTED MOTOR FPM-12, FPM-24, FPM-115, FPM-220 Congratulations on purchase of this World Class Electric Fuel Pump! Elbow This is an Electric Fuel Pump.
More informationWPS600. Hydraulic Pressure Transducer. User s Guide. 600 bar 60 MPa 8700 psi
WPS600 Hydraulic Pressure Transducer User s Guide This accessory complies with the following standards: Electromagnetic Compatibility (EMC) Directive 2004/108/EC FCC Part 15 Pressure Equipment Directive
More informationElectronic Limit Switch Type
Electronic Limit Switch Type 3738-20 with optional solenoid valve for on/off rotary actuators Application Electronic limit switch for on/off applications to indicate the end position of rotary actuators.
More informationTBP SERIES PUMPS OPERATION & PARTS MANUAL
TBP SERIES PUMPS OPERATION & PARTS MANUAL EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable health and safety requirements
More informationSpare Parts List Filter NFD Change-Over Version
Spare Parts List Filter Change-Over Version up to 1600 l/min, up to 5 bar 1340 640 540 7840 10440 1. MAINTENANCE GENERAL Please follow the maintenance instructions! 1. INSTALLATION Before fitting the filter
More informationOPTISWITCH 6500 C Technical Datasheet
OPTISWITCH 6500 C Technical Datasheet Switch for level detection and dry-run protection Optimised sensor geometry, easy to clean Measures products with dielectric constant > 1.5 Maintenance-free KROHNE
More informationMod: KLD6-12/35XLAS-N
12/2011 Mod: KLD6-12/35XLAS-N Production code: 1914070 INSTRUCTION MANUAL LOGIC LINE PLUS HOOD Reseller Stamp for Warranty Dear customer, Above all, thank you for choosing our product and we would like
More informationISO INTERNATIONAL STANDARD. Hoists for the transfer of disabled persons Requirements and test methods
INTERNATIONAL STANDARD ISO 10535 Second edition 2006-12-15 Hoists for the transfer of disabled persons Requirements and test methods Lève-personnes pour transférer des personnes handicapées Exigences et
More informationUser Instruction Manual Oxford Classic Digital Weigh Scale. To avoid injury, read user manual prior to use.
User Instruction Manual Oxford Classic Digital To avoid injury, read user manual prior to use. Oxford English Contents 1. Introduction: About Your Scale... 3 2. Assembly and Commissioning Instructions...
More informationELEMENT. Product family datasheet. Constant Voltage Non dimmable
ELEMENT Constant Voltage Non dimmable Areas of application _ Suitable for luminaires of protection class II _ Decorative lighting in hospitality, restaurants and Shops _ Shelf lighting for shops _ Cove
More informationA brief guide for identification of non-compliant construction machinery. Is this. Compactor / Roller compliant with European legislation?
A brief guide for identification of non-compliant construction machinery Is this Compactor / Roller compliant with European legislation? Introduction Construction equipment placed on the EU market for
More informationDL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05
DL 0 Battery Powered for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless
More informationDMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.
TEMATEC GmbH Postal address:: Postbox 6 House address Löhestr. 7 5759 Hennef 577 Hennef Fon (+49) 0 4-87 0-0 Fax (+49) 0 4-87 0-0 http: // www.tematec.de e-mail: team@ tematec.de TEMATEC GmbH Data Sheet
More informationResistance thermometer For sanitary applications Model TR22-B, for orbital welding
Electrical temperature measurement Resistance thermometer For sanitary applications Model TR22-B, for orbital welding WIKA data sheet TE 60.23 for further approvals see page 11 Applications Sanitary applications
More informationEC Type-Approval Certificate UK 2655 Revision 2
UK 2655 V(0)a EC Type-Approval Certificate UK 2655 Revision 2 Issued by: National Measurement Office Notified Body Number 0126 In accordance with the requirements of the Non-automatic Weighing Instruments
More informationP r e s s u r e i S w i t c h e s V a c u u m i S w i t c h e s PressureiTransmitters
P r e s s u r e i M o n i t o r i n g P r e s s u r e i S w i t c h e s V a c u u m i S w i t c h e s PressureiTransmitters TRADITION AND INNOVATION From a mechanical workshop to an international industrial
More informationOperating Instructions
Resistance Thermometer Clamp-on technology for temperature measurement on pipes, Type Series GA261x Operating Instructions 1 General Information... 2 1.1 General Safety Notes... 2 1.2 Intended Use... 2
More informationBlueSwan Pipette Controller
BlueSwan Pipette Controller BSST-0100 Operation Manual Ver. 1.0 Copyright 2016 Blue-Ray Biotech Corp. All Rights Reserved. Table of Contents 1. Safety Precautions... 1 2. General Description... 2 2.1
More informationOffshore Fuelling Systems
Offshore Fuelling Systems Fuel Management System Manufacturers, Aviation & Diesel Filtration Specialists Introduction: Eastern Petroleum Supplies Ltd are designers and manufacturers of a wide range of
More information