PFA015 Owner s Manual

Size: px
Start display at page:

Download "PFA015 Owner s Manual"

Transcription

1 E. 0 S., Kamas, UT engineer approved PFA0 Owner s Manual Table of Contents. Product Information. Specifications & Performance.... Temperature Limits.... Dimensions.... Bill of Materials.... Installation. Precautions.... Warnings.... Advantages.... Environment & System.... Installation Instructions.... Control & Monitoring. Shift Logic for Fiber-optic Pumps.... Fiber Optic Stroke Detection Installation...9. Calibrating D0 Amplifier for Stroke Detection...9. Conductivity Leak Detection Installation...0. Fiber Optic Leak Detection Installation...0. Calibrating D0 Amplifier for Leak Detection.... Pump Service. Ordering Instructions.... Rebuild Information.... Rebuild Kits & Parts.... Return Pump for Service.... Warranty & Accessories P:..00 support@wkfluidhandling.com Version.0. May 0

2 PFA0 Owner s Manual Dear valued customer, Thank you for purchasing a White Knight PFA0 pump. Our dedicated team designs products to meet your exacting specifications with the highest commitment to quality. White Knight provides the highest quality fluid handling products through controlled, consistent in-house engineering and manufacturing. Our safe, reliable products offer superior performance, optimized efficiency, and simplified maintenance. We continue to lead the industry with new technologies and products. Our patented designs offer a variety of size and material options to meet stringent requirements of high-pressure chemical delivery systems; high-temperature re-circulation processes; chemical reclaim and bulk transport applications; as well as slurry systems. White Knight has received many prestigious awards for innovation and manufacturing programs. We rigorously manage our quality assurance processes to ensure consistency and reliability. Our quality controls include strict cleanliness procedures and consistent manufacturing processes. For example, product assembly and testing is done in a temperature and humidity-controlled cleanroom. Please peruse this manual before installing your White Knight product. It details installation requirements and setup instructions, and provides additional information and accessories to enhance the product s functionality. Our team has gone to great lengths to ensure our products serve your needs and meet your requirements. Further, we provide the highest quality products at the best value, and we back them up with excellent warranties and world class support. Sincerely, Steve Smith, CEO White Knight Fluid Handling P:..00 support@wkfluidhandling.com Ver..0. May 0

3 PFA0 Owner s Manual. Product Information. Specifications & Performance Model PFA0 PFASD0 Max Flow Rate* Displacement Per Cycle*. lpm (. gpm) 0.09 liters (0.0 gal) TBD lpm (TBD gpm) 0.09 liters (0.0 gal) Cycles per min 90 max TBD max Air Connection / in / in Weight. kg (.9 lb). kg (.9 lb) Suction Lift* m (0 ft) Flooded suction Pressure** 9. db(a) at 00 psi 0 CPM. db(a) at 00 psi max CPM Power**. db(a) at 00 psi 0 CPM. db(a) at 00 psi max CPM * May vary by configuration or system. Suction lift diminishes over time. Recommended installation level less than ft above source. To calculate displacement, divide flow rate by CPM. ** Sound measured in accordance with ISO9-:99. *** Dry-run capable PFASD0 pumps require flooded suction and may have reduced warranty. Contact support for details. Sound Max Fluid Temperature Environmental Temperature Max Supply Air Pressure Min Startup Air Pressure Fluid Path Materials Non-Fluid Path Materials Stroke Detection Leak Detection Electronic Control 00 C ( F) min: 0 C ( F) max: 0 C ( F) Bar (00 psi). bar (0 psi) PTFE, PFA PTFE, PFA, PP Fiber optic with or without D0 sensor Fiber optic with or without sensor, or conductivity CPC, CPT, or custom. Call for details. Discharge Pressure PFA0 Performance 00 PSI 0 PSI 0 CPM 0 SCFM SCFM 0 CPM 0 PSI 0 CPM 0 PSI 0 CPM 0 SCFM Air Pressure Air Consumption Cycle Rate Discharge Pressure PFASD0 Performance 00 PSI 0 PSI 0 PSI 0 PSI 0 CPM 00 CPM 0 CPM SCFM 0 SCFM SCFM SCFM 0 CPM 0 CPM. SCFM 00 CPM Air Pressure Air Consumption Cycle Rate 0 0 PSI SCFM CPM 0 0 PSI SCFM 0 0 PSI Bar LPM PSI Bar LPM m /hr m /hr GPM Liquid Flowrate How to Read Charts Draw a horizontal line at your discharge pressure and vertical line at desired flow rate. At line intersect, estimate required air pressure, resultant cycle rate and air consumption. GPM Liquid Flowrate Example At Bar (0 psi) discharge pressure and 0 psi supply pressure, PFA0 pumps provide lpm ( gpm) flow rate. They would cycle at ~ CPM, and exhaust SCFM of air. *Graph is for reference only. Performance was measured utilizing / in (/ in ID) air line and -/ in (-/ in ID) liquid lines with ft flooded suction. Performance may vary in your system. P:..00 support@wkfluidhandling.com Ver..0. May 0 P.

4 PFA0 Owner s Manual. Temperature Limits 0 F 0 F 0 F 0 F 0 F 90 F 00 F 0 F.0 00 Air Supply Pressure Bar 0 C C 0 C C 0 C C 90 C 9 C 00 C. Dimensions Dimensions in [mm] in.0 MOUNT WITH EA. /" (0 mm) SOCKET HEAD CAP SCREWS PSI C L P:..00 support@wkfluidhandling.com Ver..0. May 0 P.

5 PFA0 Owner s Manual. Bill of Materials OPTIONAL COMPONENT USE WITH SINGLE PROBE STROKE DETECT OPTIONAL COMPONENT(S) NOT INCLUDED PFA0 BILL OF MATERIALS ITEM NO. PART NUMBER DESCRIPTION QTY. -TE-00 BODY, PUMP, PSA0 -EP-000 HEAD, RIGHT, PFA00 -EP-00 HEAD, LEFT, PFA00 00-VI-000 DIAPHRAGM,. 00-MP-000 BALL, CHECK, /" -MP-000 SEAT, CHECK 0-TE-000 TOP CHECK PLUG -MP-000 CAGE, CHECK 9 -MP-000 SEAL, SHAFT 0 -PF-00 SHAFT 090-UH-000 BODY, QEH, 0 0-FP-000 BAFFLE POROUS POLY 0/0 L QEV 0-PP-000 MESH, QEV 0 & 0 0-NP-000 CAP, MUFFLER, QEV 0L & 0L 0-UH-000 SEAT, QEV EXHAUST, 0L & 0L 00-PF-000 BODY, FLARETEK, /" 0-PF-000 NUT, FLARETEK, /" 00-PF-000 CAP, END, SINGLE PROBE DUAL DETECT TE-000 PLUG, NPT, /" TE-000 /" PLUG SHORT 000-VI-0- O-RING, 0 X NP-000 PLATE, BASE, ASSEMBLY 00-MP-00 BELWS ASSEMBLY, 0L, FO, SINGLE PROBE DUAL DETECT 00-MP-00 BELWS ASSEMBLY 00-XX-000 STROKE DETECT FIBER OPTIC ASSEMBLY WITH WIRE CUTTER P:..00 support@wkfluidhandling.com Ver..0. May 0 P.

6 PFA0 Owner s Manual. Installation. Precautions Handling Do NOT lift pump by fiber optic cables, quick exhaust valves nor air tubing. Installation Orientation PFA0 pumps must be installed in an upright position. The check valves are actuated by gravity and/or flow, and they will not seat if the pump is not upright. Timer Mode PFA0 pumps require an end of stroke detection mechanism (pressure switch) to prevent over stroking in timer mode. Operating a PFA0 in timer mode without stroke detection will void the pump warranty. Required Air Flow (Shuttle Valve) PFA0 pumps require / in minimum orifice with unrestricted air flow. Required Air Flow (Solenoid Valve) PFA0 pumps require a 0. Cv solenoid. Using a reduced Cv will reduce flow rates. Using a valve with more than 0% greater Cv will change operating parameters, reduce pump life and void the warranty. Under Supply of Air PFA0 pumps operate erratically or stall when air supply is insufficient. Ensure use of air supply pressures higher than averaged air consumption lines in performance charts. Air supply lines and fittings must meet minimal inner diameter requirements shown in the installation instructions. Air Supply Pressure Operating PFA0 pumps ~% below max air pressure may significantly extend pump life. PFA0 pumps require 0 psi minimum air pressure. Operation above Bar (00 psi) may damage the pump and void the warranty. Suction Lift PFA0 pumps have an initial suction lift capacity of ft. For best results minimize suction lift. Liquid Inlet/Outlet Connections PFA0 liquid ports are not NPT nor any other standard. Use of connectors other than those supplied by White Knight will damage the pump and void the warranty. Liquid Line Restriction PFA0 pumps may be controlled by closing liquid outlet lines. However, restricting liquid supply lines increases wear and should be avoided. Do NOT pump against a closed liquid inlet. It will damage the pump and void the warranty. Running Dry PFA0 pumps use the pumped liquid to lubricate their shafts. The pumps will cycle faster and wear more than normal when run dry, which may cause damage and loss of self-prime abilities. Standard models should not be run dry after startup and are not warrantied under dry run conditions. Dry-run capable PFASD0 models may run dry for short periods. Warranty of dry-run models is one-year. Extended warranties are available. Pulse Dampener with Shuttle Valve Air supply pressure to PFA0 pumps should be at least ten psi higher than the liquid line pressure when using a pulsation dampener. Failure to do so may cause erratic operation. Cross Contamination PFA0 pumps use porous material that may retain chemicals. Take precautions to avoid cross contamination. P:..00 support@wkfluidhandling.com Ver..0. May 0 P.

7 PFA0 Owner s Manual. Warnings Pressurized Material Pumps in use contain pressurized materials. Eliminate liquid and air pressure via shut off valves before pump is serviced or removed from the system. High Temperature Heat may transfer to exterior surfaces when pumps operate with high temperature fluids. Avoid direct contact with the pump when high temperature fluids are present. Hazardous Chemical Use appropriate personal protective equipment when handling pump. Reference Material Safety Data Sheet (MSDS) for information specific to your chemicals. Loud Noise Pump exhaust air contributes to work area noise levels. Only operate pumps with approved muffler media, and use ear protection in noisy conditions.. Advantages Head Pressure / Dead-Head PFA0 pumps can be controlled by adjusting their liquid outlet pressures and can be installed with head pressures up to dead-head (e.g. equal liquid and air pressures) with no damage to the pump. Thermal Cycling PFA0 pumps require no maintenance when operated within their performance range, even in thermal cycling applications.. Environment & System Oversized Inlet Line Pumps operate optimally with liquid inlet lines larger than the liquid outlet lines. This reduces strain on the bellows and may reduce pulsation in the pump outlet. Clean Supply Air (CDA) PFA0 pumps require use of Class air for particles and moisture per ISO -. Use 0 micron filter; maintain -0 C dew point. A point-of-use filter is recommended during first six months of operation in new fabs/systems due to high risks of debris that can damage pumps and void warranty. Flammable Solvents PFA0 pumps are not constructed from conductive materials. System that pump flammable solvents should be properly grounded to avoid ignition by static charge. A River s Edge test of isolative pumps with flammable liquids indicated that liquids must be grounded and other procedures should be followed. Copy of test available. Pumping Liquids Near Boiling Point Minimizing suction lift reduces pulsation and the potential for boiling or outgassing of liquid in the inlet of the pump. Although reciprocating pumps can pull suction lift, pump performance and life increase when suction lift is minimized or eliminated. Abrasive Slurry Pumping abrasive slurry may accelerate wear of components. PFA0 pumps are warrantied when used with slurry. However, normal wear is not covered by warranty. Environmental Temperature PFA0 pumps are rated for 0 C ( F) - 0 C ( F) environmental temperatures. Do not freeze fluid in pump. Operation below 0 C may accelerate wear. Normal wear is not covered by warranty. P:..00 support@wkfluidhandling.com Ver..0. May 0 P.

8 PFA0 Owner s Manual D0 amplifier must be calibrated before attaching fiber optic probes to the pump.. Installation Instructions Pull-back dismount is standard. See steps.-. for forward dismount.. Set lever to up position. Slide base plate forward or pump body backward.. Lift pump off of base plate... Screw base plate to surface with / in or 0 mm head cap socket screws into predrilled holes. Set pump on base knobs; slide it forward. Set lever to down position.... Insert fiber-optics Attach Attach tubes and fittings fully into heads. fittings per manufacturer Push in ferrule to pump. instructions. Use backer and gripper; Tighten to wrench to hold fittings in hand-tighten nut. 0 inch-lbs. place at pump.. Set air line via / in FNPT ports on quick exhaust valves. Line must be / in minimum orifice. Push-Forward Dismount Configuration Setup Replace step with steps.-. to re-configure the base plate to pushforward dismount.. Move knobs to opposite sides.. Set pump on base knobs; slide it backward.. Move lever down to locked position. Install with Rigid Base Plate..... Remove L bracket. Set lever in neutral (up) position. Slide pump forward; lift it off base plate. Fix base plate to work station. See step above. Return pump to base plate. Move lock lever to down position. Reattach L bracket. Tighten hand tight. Liquid Inlet/Outlet Liquid ports are not NPT nor any other standard. Use of connectors other than those supplied by White Knight will damage the pump. P:..00 support@wkfluidhandling.com Ver..0. May 0 P.

9 PFA0 Owner s Manual. Control & Monitoring Programmable Control White Knight CPT- controllers monitor and adjust run mode, flow rate, leak detection and other pump operations. D0 Amplifier Electrical Hookups & Dimensions White Knight recommends Expert D0 amplifier for use with fiber optic stroke and leak detection assemblies. Standard Models and Main Unit Load Load QD hookup is functionally identical (Pink wire not used) + 0-0V dc Standard Models -0V dc Bussable Power Models 0 ma max. load Remote Teach Wire Key = Brown = White = Blue = Black = Gray Sub-Units NPN Load Load PNP + Remote Teach + -0V dc Connection From Main Unit Bus -0V dc Connection From Main Unit Bus Remote Teach 0. ± 0. mm (typ.) (0."). mm (0.").9 mm (."). mm 0.0" Mounting Bracket (included with some models). mm (."). mm (.") 9. mm (0.9") P:..00 support@wkfluidhandling.com Ver..0. May 0 P.

10 PFA0 Owner s Manual. Shift Logic for Fiber-optic Pumps Air must be sent to either side at startup to initiate movement. Pump Startup During pump operation, the timing of the solenoid valve should be dependent on sensors with no time delays. There should be no delay between reading the sensor signal and actuating the solenoid valve. Send air to left side of pump Check Sensors Send air to right side of pump Logic Only left sensor is true Only right sensor is true Air remains on either side if both sensors are true or false P:..00 support@wkfluidhandling.com Ver..0. May 0 P.

11 engineer approved PFA0 Owner s Manual. Fiber Optic Stroke Detection Installation For standard end stroke, follow steps for both sides of the pump. For single-probe dual-detect, follow steps for only the left side.. Insert fiber optic probes fully into heads. Push in ferrule and gripper; hand-tighten nut.. Open the top and slide the front face of the D0 up. Press the fiber optic ends into the holes on its front. Slide the face down to lock cables in place.. Calibrating D0 Amplifier for Stroke Detection When calibrating the D0 Amplifier for stroke detection, the pump should be in the same operating conditions it will be in during normal operation (i.e. supply air pressure, back pressure, etc.). The Fiber Optic must be installed as per the instructions in section.. Calibration: Access Dynamic TEACH Mode TEACH Sensing Conditions Return to Run Mode Push Button Remote Line Result Press and hold dynamic push button > seconds. Hold push button. Operate pump normally for seconds. Release button Hold Remote line low (to ground) > Seconds. Hold remote line low (to ground). Operate pump normally for seconds. Release remote line/switch Power LED: OFF Output LED: OFF Bar graph: & Alternately Flashing Power LED: OFF Output LED: OFF Bar graph: & Alternately Flashing Teach Accepted Power LED: ON Bar graph: One LED flashes to show relative contrast (successful setup requires minimum value of ). Sensor returns to Run Mode with new settings. Teach Unaccepted Power LED: OFF Bar graph: #,,, alternately flash to show failure to sense. Sensor returns to Run mode without changing settings. Set up again if value shows <. Upon completion of a successful learning cycle, the D0 Amplifier will continuously learn and self-teach to maintain the same cycle rate count readings. P:..00 support@wkfluidhandling.com Ver..0. May 0 P. 9

12 PFA0 Owner s Manual. Conductivity Leak Detection Installation Leaks are identified if conductive fluid contacts a sensor. Sensor provides a Sink (NPN) or Source (PNP) signal, depending on the wire setup. See the wiring diagrams below. Conductive leak detection does not qualify for use in explosion-proof environments. Conductive fluid required. See below for elbow out configuration... Remove leak Replace NPT plug in L adapter from port with probe. Hand assembly. Tighten. Attach cable to signal translator (e.g. PLC).. Fiber Optic Leak Detection Installation Sink (NPN) Connection Conductivity Leak Detect White White/Blue Load D0 amplifier must be calibrated before attaching fiber optic probes to the pump. Fiber optic sensors can melt if used at >0 C ( F), causing leak detect failure. See below for elbow out configuration. Wiring Diagrams Source (PNP) Connection Conductivity Leak Detect White White/Blue Load Power 0-0 VDC Power 0-0 VDC... Remove leak adapter and leak detect probe from fiber optic assembly. For straight out configuration replace NPT plug in L port with the probe. Hand-tighten. Insert the fiber optic cable until it contacts the bottom of the probe... Lower ferrule and gripper until Open the top and slide the front face of the D0 up. snug against the probe. Hand Press the fiber optic ends into the holes on its front. tighten female gripper nut. Slide the face down to lock cables in place. For elbow out configuration: Fiber optic Conductivity.. Replace NPT plug in L Attach fiber optic or conductivity leak port with elbow adapter. detect probe per instructions above. P:..00 support@wkfluidhandling.com Ver..0. May 0 P. 0

13 engineer approved PFA0 Owner s Manual. Calibrating D0 Amplifier for Leak Detection Step : Power On D0 Amplifier & Set Dark Operate Mode: Access Setup Mode Select Settings Return to Run Mode Push Button 0.0 s Click 0. s Press and hold both buttons > seconds. Press either button until LEDs show desired settings. Press and hold both buttons > seconds. Remote Line 0.0 s T 0. s Double-pulse remote line T T x T Pulse the remote line until LEDs show desired settings. Note: Doublepulsing remote line causes setting to back up one step. Hold remote line low > seconds. > seconds Step : Access Single-Point Dark Set Mode T T Result Green Power LED turns OFF. Output LED remains active. Icons continue to display current setup. Bargraph turns OFF. Sensor toggles through these setting combinations: - Normal Speed - No Delay (default) - Normal Speed - No Delay - High Speed - No Delay - High Speed - No Delay - Normal Speed - Delay - Normal Speed - Delay - High Speed - Delay - High Speed - Delay Green Power LED turns ON. Sensor returns to Run mode with new settings. T T Push Button Remote Line Result 0.0 s Click 0. s 0.0 s T 0. s Access Set Mode Press and hold static button > seconds. Single-pulse remote line T x Power LED: OFF. Output LED: ON (push button) OFF (remote line) Static LEDs: & alternately flashing or Step : Set Sensing Condition Set condition to leak detection sensing while probe tip is submerged in liquid. Then, remove the leak probe from liquid and reinserted into the L port. Amplifier will now signal when moisture if detected on the probe tip. Set Sensing Condition Push Button 0.0 s Click 0. s Present sensing condition Five-click static button Remote Line 0.0 s T 0. s Present sensing condition Five-pulse remote lne Result Power LED: ON. Output LED: ON (push button) OFF (remote line) Bargraph: indicators flash. Sensor returns to Run mode with new settings Power LED: ON. Output LED: ON (push button) OFF (remote line) Bargraph: #,,, flash for failure. Sensor returns to Set sensing condition. or or P:..00 support@wkfluidhandling.com Ver..0. May 0 P.

14 PFA0 Owner s Manual. Pump Service. Ordering Instructions Standard Required Options Additional Options Rev. PFA0 - F0 - LF0 - SFD0 - TF0 - A - Model Inlet Leak Stroke Outlet QEV Rev. Select Required Options. Only add desired Additional Options. Only add Outlet if different than Inlet. Contact support for revision level or copy exact code activation details. Pump Model Standard Dry-Run PFA0 PFASD0 Inlet Fitting Front Straight Only Flaretek / in. F0 Compatible / in. F0 / in. F0 / in. F Tube Out / in. T0 / in. T0 / in. T Weldable / in. W0 / in. W Pillar S-00 / in. P0 / in. P FNPT / in. N0 / in. N0 / in. N0 / in. N Synchro- / in. S0 Flare / in. S0 / in. S / in. L0 PrimeLock / in. L Leak Detection ft fiber optic cable with no amplifier LF0 ft fiber optic cable with D0 amplifier LF ft fiber optic cable with no amplifier LF ft fiber optic cable with D0 amplifier LF ft conductivity cable LC0 Stroke Detection Dual Probe Options ft fiber optic cable with no amplifier SFD0 ft fiber optic cable with D0 amplifier SFD ft fiber optic cable with no amplifier SFD ft fiber optic cable with D0 amplifier SFD Single Probe, Dual Detect Options Single probe, dual detect, no fibers SFS ft fiber optic cable with no amplifier SFS0 ft fiber optic cable with D0 amplifier SFS ft fiber optic cable with no amplifier SFS ft fiber optic cable with D0 amplifier SFS * Fiber optic cables ordered separately. Fiber optics are required for operation. Standard configuration includes dual probe WITHOUT fibers. See stroke detection options to order fiber optic cables or single probe option. Timer mode operation requires end-of-stroke detection. Use of timer mode without stroke detection voids the warranty. This pump includes Quick Exhaust Valves (QEVs). QEVs must be used with this pump. Running it without QEVs voids its warranty. Customers may use their own QEVs with the optional NPT adapter. Outlet Style Front Straight (default) Top Straight F T Outlet Fitting Flaretek / in. F0 Compatible / in. F0 / in. F0 / in. F Tube Out / in. T0 / in. T0 / in. T Weldable / in. W0 / in. W Pillar S-00 / in. P0 / in. P FNPT / in. N0 / in. N0 / in. N0 / in. N Synchro- / in. S0 Flare / in. S0 / in. S / in. L0 PrimeLock / in. L Quick Exhaust/Air Inlet / in NPT Adapter A P:..00 support@wkfluidhandling.com Ver..0. May 0 P.

15 PFA0 Owner s Manual. Rebuild Information Pumps fully rebuilt by White Knight, certified rebuilders, or technicians certified by White Knight receive full warranty renewal. Details below. White Knight Rebuilds Request factory rebuilds by web form at: An RMA# will be provided after processing. *Customers must follow decontamination instructions in Section. when returning a pump to White Knight. Certified Rebuilders White Knight s global network of certified rebuilders expedite rebuild turn-around time and minimize shipping costs. Find certified rebuilders at: Rebuild Pump as Certified Technician White Knight offers trainings to certify technicians to rebuild pumps. Technicians who pass the training are issued a two-year certification. During the two years, parts in pumps rebuilt by the technician receive a full warranty. See: Rebuild Kits & Parts Rebuild kit for PFA0 is RBPFA0-. Rebuild kit for PFASD0 is RBPFASD0- (labor not included). To request rebuilds by White Knight, use RBPFA0- or RBPFASD0-, respectively (labor included). 0 Pump rebuilds require tool kit: 00-XX-00 (Legacy# PFA0-0) Dry-run (SD) pumps use different shaft and shaft seals. Contact White Knight for details. 9 RBPFA0- ITEM NO. PART NUMBER DESCRIPTION QTY. 0-MP-00 BELWS, A & H, 0L 00-VI-000 DIAPHRAGM,. 00-MP-000 CHECK BALL /" -MP-000 CHECK SEAT BOTTOM HI-FW L & 0L -MP-000 CHECK CAGE TOP HI-FW L & 0L -MP-000 SEAL, SHAFT, 0L -PF-00 SHAFT, SOLID, PFA, 0L 0-FP-000 BAFFLE,.00" 9 0-UH-000 SEAT, QEV EXHAUST, 0L & 0L 0 0-TE-000 STEM, SD TARGET, 0L 0-BP-000 EXTENSION, TARGET, UNIVERSAL 0-TE-000 EXTENSION, TARGET,. 0-BP-000 BLANK, TARGET,. P:..00 support@wkfluidhandling.com Ver..0. May 0 P.

16 PFA0 Owner s Manual. Return Pump for Service Follow decontamination instructions when returning a pump for service. NOT REMOVE PAGE FROM MANUAL. Copy page from manual or download at Decontamination Instructions PRINT COMPLETED DECONTAMINATION CERTIFICATION. IT MUST BE INCLUDED IN YOUR RMA SHIPMENT. White Knight products are designed for use with caustic and otherwise dangerous liquids. Handle every product as if it contains dangerous chemicals whether or not it actually does. Only those with adequate safety training should attempt to handle used pumps. Wear adequate safety gear appropriate for chemicals that have been in the pump. Review relevant Material Safety Data Sheets (MSDS) before handling the pump. Review emergency numbers for use in event of an accident. Prepare Ph papers, showers, antidotes, clean-up equipment, neutralizers, and other safety devices used to detect, neutralize or minimize effects of chemicals described in appropriate MSDS documents. Rinse with DI Water Circulate DI water through pump for twenty minutes before disassembly and/or double bagging for shipment. If pump is nonfunctional, force DI water from inlet through outlet for 0 minutes before shipment preparations. Remove Pump from Station:. Disconnect liquid tubing connectors from front of pump (opposite shuttle valve).. Plug NPT fittings with PTFE plug, Flare fittings with flare nose cover and cap, or other plug or cap as recommended by connector supplier.. Disconnect air supply tubing from face of shuttle valve.. Loosen mount screw from base plate. (Note: do not remove screw from base plate).. Remove base plate using proper tool for the fastening devices (e.g. Allen wrench or screw driver). Note: Base plate may stay if needed for replacement pump to be used.. Return all removed parts to the pump. Return Pump to White Knight:. Rinse pump with DI water as described above after removing it from its station.. Drain remaining DI water from the pump inlet and outlet liquid tubing connectors.. Plug liquid outlets as described in the Remove Pump from Station section above.. Dry the pump, double bag it, and seal it in thick polyethylene bags.. Return the pump to its original packaging.. Include MSDS for the chemical that the pump was handling in the box with the pump.. Obtain RMA number from White Knight and write it on the outside of the box.. Ship to White Knight following all rules, regulations and laws regarding shipment of dangerous materials. Ship freight pre-paid. No collect shipments will be accepted. Unauthorized use of White Knight shipping accounts will result in the adding of freight to the bill in addition to a service charge. Include All Pump Components: Pumps returned to White Knight for evaluation, service or repair must be complete with all components, including but not limited to base plate, mount screws, tubing connectors, tubing connector caps, flare noses, shuttle valves, mufflers, and tubing. Missing parts will be added to the pump and charged to the customer. P:..00 support@wkfluidhandling.com Ver..0. May 0 P.

17 PFA0 Owner s Manual NOT REMOVE PAGE FROM MANUAL. Copy page from manual or download at Decontamination Certification COMPLETE AND PRINT THIS FORM. IT MUST BE INCLUDED IN YOUR RMA SHIPMENT. I, the undersigned employee of, certify that all decontamination and safety procedures described in Decontamination Instructions section have been followed for return of product below. RMA#: (We cannot process returns without an RMA number.) Serial#: (We cannot process returns without a product serial number.) Metal Exposure: (Check all that apply. Write in other metals if necessary.) Product was used in a Metal Process. Yes No Product was used in a Copper Metal Process. Yes No Product was used with: Aluminum Cobalt Gold Lead Nickel Platinum Silver Tin Titanium Tungsten Zinc Other: Chemical Exposure: (Check all that apply. Write in other chemicals if necessary.) Product was NOT used in chemicals (DI Water only). Product was used in chemicals. Ammonia Ammonium Hydroxide Hydrochloric Acid Hydrofluoric Acid Hydrogen Peroxide IPA Nitric Acid Phosphoric Acid Sulfuric Acid Other: Shipping Information: Please indicate metal processes to which the product has been exposed by clearly and conspicuously labeling the outside of the return package with the metal. Products exposed to Metal Processes must be sent to the following address: White Knight Fluid Handling East 0 South, Suite B Kamas, UT 0 Products NOT exposed to Metal Processes must be sent to the following address: White Knight Fluid Handling East 0 South, Suite C Kamas, UT 0 Print Name: Signature: Date: P:..00 support@wkfluidhandling.com Ver..0. May 0 P.

18 PFA0 Owner s Manual. Warranty White Knight follows strict manufacturing, assembly and testing procedures to ensure consistency and reliability. White Knight warrants PFA0 pumps and components are free from defects in materials and workmanship for two years from our shipment date or your installation date if provided within 90 days of shipment from our facility. Failures due to normal wear, misuse, abuse or unauthorized disassembly nullify this warranty. White Knight does not guarantee the suitability of products for specific applications. White Knight is not liable for any damage or expense resulting from use or misuse of its products in any application. Responsibility is limited solely to repair or replacement of defective products or components. Prior written, faxed or ed approval must be obtained from White Knight before returning any product or component for warranty consideration. All determinations regarding cause of failure are made by White Knight, and all decisions regarding warranty fulfillment or nullification are made by White Knight. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, INCLUDING ANY GUARANTEE OF SUITABILITY FOR ANY PURPOSE. NO VARIATIONS OF THIS WARRANTY SHALL BE HONORED NOR CONSIDERED LEGALLY BINDING, EXCEPT WRITTEN AGREEMENTS SIGNED BY THE CEO OF WHITE KNIGHT FLUID HANDLING. Steve Smith, CEO White Knight Fluid Handling Accessories See ordering instructions or contact us for details. Stroke Detection Fiber Optic stroke detection with or without sensor Solid state pressure switch Solid state dual pressure switch Leak Detection Fiber Optic leak detection with or without sensor Conductivity leak detection CPT- Control/monitor run mode and flow rate. Catcher Pre-Filters In-line and pump-mounted options Large through holes to avoid loading Filter may be removed without removing the Catcher from the pump or the line. Pumps damaged by passing solids that use a Catcher are repaired as in warranty. Filter Housing 00% non-metallic Allows for filter changing without disconnecting the inlet/outlet lines Rated for temperatures up to 0 C Install with industry standard connections Designed to allow for thermal cycling Upright and inverted installation options Quick Exhaust Valves Allows for immediate escape of exhaust air reducing pulsation and exposure of solenoid valve to corrosive fumes In-line and pump-mounted options UHMW-PE design Comes standard with a one-year warranty Pulse Dampeners Uses same CDA as supplied to pump In-line and pump-mounted options Sizes available for all PFA Series pumps Self-adjusting, Auto-Level Valve is regulated by liquid line pressure P:..00 support@wkfluidhandling.com Ver..0. May 0 P.

19 PFA0 Owner s Manual P:..00 support@wkfluidhandling.com Ver..0. May 0 P.

20 White Knight Support E. 0 S. Kamas, UT 0 Phone:..00 Toll Free:.9. Fax:.. support@wkfluidhandling.com Part No. 00-LM-00 P:..00 support@wkfluidhandling.com Version.0. May 0

PXU140 Owner s Manual

PXU140 Owner s Manual 8 E. 0 S., Kamas, UT 80.8.00 888.9. https://wkfluidhandling.com engineer approved Table of Contents. Product Information. Specifications & Performance.... Temperature Limits.... Dimensions.... Bill of

More information

PPM100 Owner s Manual

PPM100 Owner s Manual PPM100 Owner s Manual 187 E. 670 S., Kamas, UT 84036 435.783.6040 888.796.2476 https://wkfluidhandling.com Manuals available online at: wkfluidhandling.com/owners-manuals Manual Part #18200-LM-0001 Copyright

More information

PSD06 Owner s Manual. Manuals available online at: wkfluidhandling.com/owners-manuals

PSD06 Owner s Manual. Manuals available online at: wkfluidhandling.com/owners-manuals 187 E. 670 S., Kamas, UT 84036 435.783.6040 888.796.2476 https://wkfluidhandling.com PSD06 Owner s Manual Manuals available online at: wkfluidhandling.com/owners-manuals Manual Part #18200-LM-0041 Copyright

More information

WHITE KNIGHT. White Knight Fluid Handling Inc. 187 E 670 S Kamas, Utah USA

WHITE KNIGHT. White Knight Fluid Handling Inc. 187 E 670 S Kamas, Utah USA WHITE KNIGHT AT100 Owner s Manual White Knight Fluid Handling Inc. 187 E 670 S Kamas, Utah 84036 USA Revision 10 Phone 435.783.6040 Fax 435.783.6128 Toll Free 888.796.2476 wkfluidhandling.com 0 Revision

More information

MAXIM 50D PUMP. Operation / Maintenance Manual

MAXIM 50D PUMP. Operation / Maintenance Manual Phone: 800-669-1303 or 801-561-0303 Fax: 801-255-2312 e-mail: treborservice@idexcorp.com MAXIM 50D PUMP Operation / Maintenance Manual SERIAL NUMBER (located on top of product): PATENTS: U.S. 09642426,

More information

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL Air Operated Double Diaphragm Pump M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL 0.5 I.O.M rev 05. 12/2015 INDEX Title Section Introduction.1 Safety.2 Warranty, General

More information

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES APCO ASR-400/450 SEWAGE AIR RELEASE VALVES Instruction D12005 December 2012 Instructions These instructions provide installation, operation and maintenance information for the APCO ASR- 400/450 Sewage

More information

Versa-Matic. Operating Manual. 3/8" Bolted Plastic Pumps. Polypropylene Kynar

Versa-Matic. Operating Manual. 3/8 Bolted Plastic Pumps. Polypropylene Kynar Versa-Matic Operating Manual 3/8" Bolted Plastic Pumps Polypropylene Kynar E8 SAFETY WARNINGS Read these instructions completely before installation and start-up. It is the responsibility of the purchaser

More information

Integrated Flow Control Module for Slurries and Chemicals LFC-7000

Integrated Flow Control Module for Slurries and Chemicals LFC-7000 Integrated Flow Control Module for Slurries and Chemicals LFC-7000 Operating Instructions and Quick-Start Guide TABLE OF CONTENTS Introduction 3 Storage and Handling 3 Installation Instructions 4 Operating

More information

OPERATION & SERVICE MANUAL

OPERATION & SERVICE MANUAL OPERATION & SERVICE MANUAL Model: 07-3000-1921 Defueler 06/2007 Rev. 07 Tronair, Inc. Phone: (419) 866-6301 800-426-6301 1 Air Cargo Pkwy East Web: www.tronair.com Swanton, OH 43558 Email: sales@tronair.com

More information

1/2" AIR DRIVEN DIAPHRAGM PUMP

1/2 AIR DRIVEN DIAPHRAGM PUMP 1/2" DRIVEN DIAPHRAGM PUMP OPERATION AND SERVICE GUIDE O-1225D NOV. 2008 Page 1 of 6 Refer to Bulletin P-605, Parts List P-9151 DRIVEN, DOUBLE DIAPHRAGM PUMP MANUAL Congratulations on purchasing one of

More information

OPERATOR S MANUAL AND SALES AND ENGINEERING DATA

OPERATOR S MANUAL AND SALES AND ENGINEERING DATA OPERATOR S MANUAL AND SALES AND ENGINEERING DATA INCLUDING: SPECIFICATIONS, SERVICE KITS, GENERAL INFORMATION, PARTS, TROUBLESHOOTING. INCLUDE MANUALS: AF044X-XX Air Motor (pn 97999-1466) & S-632 General

More information

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

Air Operated Diaphragm Pumps Operating and Maintenance Instructions Product & Chemical Disclaimer The user must take responsibility in the selection of the products materials of construction. Empire Pumps Ltd will act in an advisory role and offer recommendations; however,

More information

OPERATION MANUAL NT50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 7/11 rev. 1

OPERATION MANUAL NT50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 7/11 rev. 1 OPERATION MANUAL NT50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS A JDA Global Company 7/11 rev. 1 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to 93.3 C 0 F to 200 F Buna-N -12.2

More information

IONIZATION SOLUTIONS

IONIZATION SOLUTIONS ó IONIZATION SOLUTIONS Air Ionizing Cartridge Model 6110/6110A User s Manual About Simco-Ion Simco-Ion develops, manufactures, and markets system solutions to manage electrostatic charge. As the world's

More information

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps Installation Operation Repair Parts PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps Specifications Motor Type: 12 VDC, permanent magnet, totally enclosed, non-ventilated Leads: 14 AWG, 12

More information

EPIC. Express Line Proudly Manufactured in the USA by Check-All Valve. Rev. E

EPIC. Express Line   Proudly Manufactured in the USA by Check-All Valve. Rev. E EPIC BY Express Line www.epiccheckvalves.com Proudly Manufactured in the USA by Check-All Valve Express Line EPIC By Check-All Valve In the beginning... the first Check-All valve was designed and built

More information

E8 Mini-Matic 3/8" Bolted Plastic Pumps Operating Instructions

E8 Mini-Matic 3/8 Bolted Plastic Pumps Operating Instructions E8 Mini-Matic 3/8" Bolted Plastic Pumps Operating Instructions Polypropylene SAFETY WARNINGS Read these instructions completely before installation and start-up. It is the responsibility of the purchaser

More information

NT HIGH-TEMPERATURE ELECTRONIC FLOWMETER, MODEL 4401

NT HIGH-TEMPERATURE ELECTRONIC FLOWMETER, MODEL 4401 P/N 1400 (Rev. A 08/12) NT HIGH-TEMPERATURE ELECTRONIC FLOWMETER, MODEL 4401 User Guide Table of Contents Introduction... 2 Dimensions... 3 Installation... 5 Provided Equipment... 5 Operating Environment...

More information

OPERATOR S MANUAL A

OPERATOR S MANUAL A OPERATOR S MANUAL 670144-A INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 12-18-15 1/4" DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC) (REV: A) 67 0144-A READ THIS MANUAL CAREFULLY BEFORE INSTALLING,

More information

OPERATION MANUAL NT80 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 5/13 rev.2

OPERATION MANUAL NT80 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 5/13 rev.2 OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS A JDA Global Company 5/13 rev.2 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to 93.3 C 0 F to 200 F Buna-N -12.2 C to 82.2 C 10 F to 180

More information

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump ACHL Series Pump Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump Catalog: 02-9245ME February 2013 Model # Serial # Drawing # Order # Mfg. Date Table of Contents page

More information

PowerFLO 5800/5900 Series

PowerFLO 5800/5900 Series PowerFLO 5800/5900 Series 5830/5930: 3.0 GPM 5836/5936: 3.6 GPM Inches (mm) Bypass Models Demand Models Switch 1.87 (47.5) 7.58 (192.5) 7.58 (192.5) 9.08 (230.6) 5840/5940: 4.0 GPM 5850/5950: 5.0 GPM Inches

More information

CHEM-FEED. Engineered Skid Systems. ProSeries. by Blue-White Ind.

CHEM-FEED. Engineered Skid Systems. ProSeries. by Blue-White Ind. CHEM-FEED Engineered Skid Systems R Single pump model number CFS-1AA-AAAAAA Shown with Chem-Pro C2 pump, sold separately Dual pump model number CFS-2AA-AAAAAA Shown with Flex-Pro A3 pump, sold separately

More information

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS PumpAgents.com - Click here for Pricing/Ordering Model 36600-Series ELECTRIC BILGE PUMPS FEATURES Self-Priming Diaphragm Design Allows Dry Running Quiet Operation Built-in Hydraulic Pulsation Dampener

More information

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES Instruction D12043 June 2016 DeZURIK Instructions These instructions provide installation, operation and maintenance information for APCO CRF-100A Rubber

More information

Jaeco AgriPumps for Chemigation

Jaeco AgriPumps for Chemigation Jaeco AgriPumps for Chemigation A Better Way to Farm Designed to Meet Rugged Ag Pivot System Applications Jaeco Metering (Injection) AgriPumps Serving Farmers for over Fifty-Five Years For over fifty-five

More information

Operation & Service Manual

Operation & Service Manual Operation & Service Manual Model: 08-4048-0013 05/2008 - Rev. 01 Includes Illustrated Parts List 1740 Eber Rd Tronair, Inc. Phone: (419) 866-6301 Holland, OH 43528-9794 www.tronair.com 800-426-6301 USA

More information

Owner s Manual Pelican Whole House Iron and Manganese Filtration System

Owner s Manual Pelican Whole House Iron and Manganese Filtration System Owner s Manual Pelican Whole House Iron and Manganese Page 2 Copyright 2011 Enviro Water Solutions Inc. All rights reserved. All information contained herein is the property of. makes no warranty of any

More information

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG25 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev.

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG25 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev. OPERATION MANUAL NTG25 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models 316 S.S. Models A JDA Global Company 1/14 rev. 3 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to

More information

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5 MODELS 282050, 282716 & 283513 AIR OPERATED CHASSIS PUMP SERIES A OWNER/OPERATOR MANUAL SPECIFICATIONS Airmotor effective dia. in. 2.5 Airinlet Material outlet 1/4 NPTF 1/4 NPTF Liquid to Air Pressure

More information

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev.

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev. OPERATION MANUAL NTG50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models 316 S.S. Models A JDA Global Company 1/14 rev.3 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to

More information

Model &

Model & PumpAgents.com - Click here for Pricing/Ordering Model 31765-0092 & 31765-0094 Dual Sensor Max VSD WATER PRESSURE SYSTEM AUTOMATIC TWO STAGE WATER SYSTEM WITH PUMPGARD STRAINERS IDEAL FOR PLEASURE AND

More information

GA-160 Gas Amplifier

GA-160 Gas Amplifier GA-160 Gas Amplifier INSTALLATION, OPERATION & MAINTENANCE MANUAL INTERFACE DEVICES, INC. 230 Depot Road, Milford, CT 06460 Ph: (203) 878-4648, Fx: (203) 882-0885, E-mail: info@interfacedevices.com www.interfacedevices.com

More information

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG40 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14, Rev.

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG40 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14, Rev. OPERATION MANUAL NTG40 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models 316 S.S. Models A JDA Global Company 1/14, Rev. 3 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to

More information

Z-Tech Severe Chemical Service Valves We Put Control Where You Need It.

Z-Tech Severe Chemical Service Valves We Put Control Where You Need It. Z-Tech Severe Chemical Service Valves We Put Control Where You Need It. Z-Tech Series Valves TABLE OF CONTENTS Ball Valves ZT 4 Series: Three Piece Flanged Ball Valve... -3 Pneumatic Actuators and Accessories...

More information

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 2 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 50 BOLTED. A JDA Global Company

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 2 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 50 BOLTED. A JDA Global Company OPERATION MANUAL 2 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 50 BOLTED AIR-OPERATED DOUBLE DIAPHRAGM PUMPS A JDA Global Company CAUTIONS - READ FIRST CAUTION: Do not apply compressed air

More information

OPERATION MANUAL. DUCTILE Models NT100 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 5/13 rev.2

OPERATION MANUAL. DUCTILE Models NT100 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 5/13 rev.2 OPERATION MANUAL NT100 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS DUCTILE Models A JDA Global Company 5/13 rev.2 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to 93.3 C 0 F to 200

More information

SAFETY MANUAL READ FIRST!

SAFETY MANUAL READ FIRST! 966-05-XX SAFETY MANUAL READ FIRST! IMPORTANT: READ THESE WARNINGS AND SAFETY PRECAUTIONS PRIOR TO INSTALLATION OR OPER- ATION. FAILURE TO COMPLY WITH THESE INSTRUC- TIONS COULD RESULT IN PERSONAL INJURY

More information

Foam Output 50 gal/min (190 ltr/min) 65 gal/min (246 ltr/min) Foaming Distance 30 feet (9 meters) 35 feet (10 meters) alcohols, ketones.

Foam Output 50 gal/min (190 ltr/min) 65 gal/min (246 ltr/min) Foaming Distance 30 feet (9 meters) 35 feet (10 meters) alcohols, ketones. INSTRUCTION MANUAL INTRODUCTION Foam cleaning is recognized as an effective method for removing oil and heavy soils from all types of surfaces. It is used for cleaning throughout the food processing, dairy,

More information

Variable Speed Misting Pump Totally Enclosed Direct Drive MODEL HDE-1PH-230VFD

Variable Speed Misting Pump Totally Enclosed Direct Drive MODEL HDE-1PH-230VFD Variable Speed Misting Pump Totally Enclosed Direct Drive MODEL 60100-HDE-1PH-230VFD SAFETY, GENERAL INFORMATION, ELECTRICAL DEFINITIONS WARNING CAN cause DEATH, SEVERE INJURY or substantial property damage.

More information

A Member of the. Integrated Metering Technologies

A Member of the. Integrated Metering Technologies I n s t a l l a t i o n M a n u a l A Member of the Integrated Metering Technologies 1.0 General and safety Do not install, operate or maintain this flow meter without reading, understanding and followingthe

More information

Model S Metallic Design Level 1

Model S Metallic Design Level 1 SERVICE BULLETIN SB1096 Model 1120-013S Metallic Design Level 1 Table of Contents Engineering Data and Temperature Limitations... 1 Performance Curve... 2 Dimensions... 3 Metric Dimensions... 4 Principle

More information

introduction < STANDARDS >

introduction < STANDARDS > Product Data Sheet introduction < STANDARDS > ASTM D1784 ASTM D2466 ASTM D2467 ASTM F439 ASTM D2464 ASTM F437 ASTM F1498 IPEX EasyFit SXE Ball Check Valves represent the latest innovation in thermoplastic

More information

Model Table of Contents. SERVICE & OPERATING MANUAL Original Instructions. Instructions Sheet:

Model Table of Contents. SERVICE & OPERATING MANUAL Original Instructions. Instructions Sheet: SERVICE & OPERATING MANUAL Original Instructions Instructions Sheet: 670989 Model 8324 Table of Contents Engineering Data and Temperature Limitations... 1 Performance Curve... 2 Dimensions... 3 Metric

More information

DI-SP/TP. Operators Guide SUBMERSIBLE HYDRAULIC PUMPS HDI Inc. PO Box 1671 Gresham OR (FAX)

DI-SP/TP. Operators Guide SUBMERSIBLE HYDRAULIC PUMPS HDI Inc. PO Box 1671 Gresham OR (FAX) DI-SP/TP SUBMERSIBLE HYDRAULIC PUMPS Operators Guide 2013 HDI Inc. PO Box 1671 Gresham OR 7030 206 274 4855 (FAX) SAFETY PRECAUTIONS INTRODUCTION Our hydraulically powered submersible dewatering and trash

More information

Open Center Compact Valve Custom Installation Guide Rev A

Open Center Compact Valve Custom Installation Guide Rev A 200-0762-01 Open Center Compact Valve Custom Installation Guide 602-0575-01 Rev A 2014-12 Overview This guide provides information for completing a custom AutoSteer valve installation on wheeled farm vehicles

More information

Operation & Technical Manual. Model: Ground Test Motor

Operation & Technical Manual. Model: Ground Test Motor Operation & Technical Manual Model: 13-6604-6600 Ground Test Motor 05/2009 Rev. 05 Includes Illustrated Parts Lists DEVELOPED IN CONJUNCTION WITH HAMILTON-SUNDSTRAND 1740 Eber Rd Tronair, Inc. Phone: (419)

More information

OPERATION MANUAL 1 POLYPROPYLENE PUMP DURA-FLO TM AIR DISTRIBUTION SYSTEM

OPERATION MANUAL 1 POLYPROPYLENE PUMP DURA-FLO TM AIR DISTRIBUTION SYSTEM OPERATION MANUAL 1 POLYPROPYLENE PUMP DURA-FLO TM AIR DISTRIBUTION SYSTEM CAUTIONS - READ FIRST CAUTION: Do not apply compressed air to the exhaust port pump will not function. CAUTION: Do not exceed 82

More information

CenterFlo Pumps. Air Operated Double Diaphragm (AODD) Pumps. Automotive Commercial Industrial

CenterFlo Pumps. Air Operated Double Diaphragm (AODD) Pumps. Automotive Commercial Industrial CenterFlo Pumps Air Operated Double Diaphragm (AODD) Pumps Automotive Commercial Industrial CenterFlo NEW CenterFlo Technology Diaphragm Pumps Advanced Technology, Superior Performance, Low Maintenance.

More information

Operators Manual. Model 3370 Air Cooled Recirculator rev.8/98

Operators Manual. Model 3370 Air Cooled Recirculator rev.8/98 Operators Manual Model 3370 Air Cooled Recirculator 110-080 rev.8/98 Table of contents Section 1. General Information 1.1 Warranty 1.2 Unpacking Section 2. Product Information 2.1 Description 2.2 Specification

More information

APCO CSV-1600 SURGE CHECK VALVE

APCO CSV-1600 SURGE CHECK VALVE APCO CSV-1600 SURGE CHECK VALVE Instruction D12022 January 2013 Instructions These instructions provide installation, operation and maintenance information for APCO CSV-1600 Surge Check Valves. They are

More information

Operation & Service Manual

Operation & Service Manual Operation & Service Manual Model: 02-1248-0112 12 Ton Single Stage Jack 11/2004 Rev. 02 Includes Illustrated Parts Lists 1740 Eber Rd Tronair, Inc. Phone: (419) 866-6301 Holland, OH 43528-9794 www.tronair.com

More information

PULSATION DAMPENERS OPERATION & MAINTENANCE MANUAL

PULSATION DAMPENERS OPERATION & MAINTENANCE MANUAL PULSATION DAMPENERS OPERATION & MAINTENANCE MANUAL 1I All-Flo Pump Co. TABLE OF CONTENTS 1.Warnings and Cautions 3 2.Pulsation Dampener Specifications 4 3.Model Matrix 5 4.Plastic Disassembly, Spare Parts

More information

FIGURE 310AM, 310AMSW & 311AM 3-PIECE BALL VALVE

FIGURE 310AM, 310AMSW & 311AM 3-PIECE BALL VALVE INTRODUCTION This instruction manual includes installation, operation and maintenance information for the figure 310AM, 310AMSW, and 311AM 3-piece 1000CWP, threaded end (NPT) or socket weld end (SW) ball

More information

Models P420A-3100 & P420A-5100

Models P420A-3100 & P420A-5100 Models P420A-3100 & P420A-5100 Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual Corrossion Resistant Pumps Contents: Installation Instructions: page 2 Specifications: page

More information

STYLE 9300 FLOW/PRESSURE METER INSTALLATION & OPERATING INSTRUCTIONS

STYLE 9300 FLOW/PRESSURE METER INSTALLATION & OPERATING INSTRUCTIONS STYLE 9300 FLOW/PRESSURE METER INSTALLATION & OPERATING INSTRUCTIONS INTRODUCTION The Style 9300 Flow/Pressure Meter from Akron is designed to offer reliable and accurate service with an easy to install,

More information

Installation, Operation, Repair and Parts Manual

Installation, Operation, Repair and Parts Manual Self-Priming Adaptor Form L-1516 (3-08) Installation, Operation, Repair and Parts Manual Description Self-priming adaptor (SPA) is a low pressure tank that provides air separation from the liquid being

More information

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators Instructions D11033 August 2013 Instructions These instructions provide information about AFR3 Filter Regulators. They are for use by personnel

More information

MSD Circle Track LS Ignition Control PN 6014CT

MSD Circle Track LS Ignition Control PN 6014CT MSD Circle Track LS Ignition Control PN 6014CT ONLINE PRODUCT REGISTRATION: Register your MSD product online. Registering your product will help if there is ever a warranty issue with your product and

More information

Model BP6150. Triplex Ceramic Plunger Pump Operating Instructions/ Manual

Model BP6150. Triplex Ceramic Plunger Pump Operating Instructions/ Manual Model BP6150 Triplex Ceramic Plunger Pump Operating Instructions/ Manual Contents: Installation Instructions: page 2 Pump Specs: page 3 Exploded View: page 4 Parts List / Kits Torque Specifications: page

More information

CRICKET Alphasonic Level Transmitter Model LA12 Owner s Manual

CRICKET Alphasonic Level Transmitter Model LA12 Owner s Manual Warranty, Service and Repair To register your product with the manufacturer, fill out the enclosed warranty card and return it immediately to: FLOWLINE Inc. 10500 Humbolt Street Los Alamitos, CA 90720

More information

FIGURE 310A & 311A 3-PIECE BALL VALVE

FIGURE 310A & 311A 3-PIECE BALL VALVE INTRODUCTION This instruction manual includes installation, operation and maintenance information for the figure 310A, 310ASW, 311A, and 311ASW 3-piece 1000CWP, threaded end (NPT) or socket weld end (SW)

More information

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves Instructions Safety Messages These instructions are intended for personnel who are responsible for installation, operation and maintenance of your DeZURIK Actuator. All safety messages in the instructions

More information

TactAir 4-Stage PCP Hand Pump. Operation Manual

TactAir 4-Stage PCP Hand Pump. Operation Manual TactAir 4-Stage PCP Hand Pump Operation Manual INTRODUCTION Thank you for choosing the TactAir 4-Stage PCP Hand Pump! Always exercise caution when operating this pump. It will allow you to fill your PCP

More information

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST. Centrifugal Pump Primer MODEL 6D, HAN-DEE PRIMER

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST. Centrifugal Pump Primer MODEL 6D, HAN-DEE PRIMER OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST Centrifugal Pump Primer 383 0893 MODEL 6D, HAN-DEE PRIMER IMPORTANT For best possible performance continuous, satisfactory operation,

More information

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual Model GXR Series Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual Consumer Pump Horizontal/Vertical Pump with built-in Regulator, Thermal Relief Valve and Siphon Injector Updated

More information

WARNING CAUTION. CAUTION Do not exceed 120 psig (8.3 bar) air-inlet pressure.

WARNING CAUTION. CAUTION Do not exceed 120 psig (8.3 bar) air-inlet pressure. 13966-300-BM SAFETY MANUAL READ FIRST! IMPORTANT: READ THESE WARNINGS AND SAFETY PRECAUTIONS PRIOR TO INSTALLATION OR OPER- ATION. FAILURE TO COMPLY WITH THESE INSTRUC- TIONS COULD RESULT IN PERSONAL INJURY

More information

Users Manual Certified Series Direct Drive Pump 1-7 LPM

Users Manual Certified Series Direct Drive Pump 1-7 LPM Users Manual Certified Series Direct Drive Pump 1-7 LPM Safety, Operating, Installation, and Maintenance Instructions 600 S 56 th Street #9 Chandler, AZ 85226 Phone: 480-507-6478 Fax: 480-838-2232 www.fogco.com

More information

Operating and Installation Instructions This Product is Protected by U.S. Patent

Operating and Installation Instructions This Product is Protected by U.S. Patent Model Number 30303 Velocity Series 200 Fuel System Operating and Installation Instructions This Product is Protected by U.S. Patent 8388322 CAUTION! This product is to be installed only by persons knowledgeable

More information

FastPrep FP120 Cell Disrupter INSTRUCTION MANUAL

FastPrep FP120 Cell Disrupter INSTRUCTION MANUAL FastPrep FP120 Cell Disrupter INSTRUCTION MANUAL Applies to FP100, FP120, and FP220 Models Qbiogene, Inc. (North America) 2251 Rutherford Road Carlsbad, CA 92008 Phone (800) 424-6101 Fax (760) 918-9313

More information

PUMP-FIT MODEL SERIES PF Assembly, Installation and Operation Manual

PUMP-FIT MODEL SERIES PF Assembly, Installation and Operation Manual PUMP-FIT MODEL SERIES PF66605 Assembly, Installation and Operation Manual EU Declaration of Conformity Pump-Fit hereby declares that the following machine(s) fully comply with the applicable health and

More information

Series CP200. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual. For Models: CP218 CP219 CP220 CP230

Series CP200. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual. For Models: CP218 CP219 CP220 CP230 Series CP200 Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual For Models: CP218 CP219 CP220 CP230 Updated 10/02 Contents: Installation Instructions: page 2 Pump Specifications:

More information

CRD610 Automatic Fitting Inserter

CRD610 Automatic Fitting Inserter CRD610 Automatic Fitting Inserter OPERATIONS MANUAL VERSION 1.2 LAST EDITED 12.12.2018 cleanroomdevices.com 1 Table of Contents Title Page. 1 Table of Contents...2 1.0 General Product & Safety Information....3

More information

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 3 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 80. A JDA Global Company

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 3 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 80. A JDA Global Company OPERATION MANUAL 3 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 80 AIR-OPERATED DOUBLE DIAPHRAGM PUMPS A JDA Global Company CAUTIONS - READ FIRST CAUTION: Do not apply compressed air to the

More information

Premium Supply. Direct Push. Models PCK-3530-DP PCK DP PCK-530-DP. Operator s Manual and Installation Instructions

Premium Supply. Direct Push. Models PCK-3530-DP PCK DP PCK-530-DP. Operator s Manual and Installation Instructions Direct Push Models PCK-3530-DP PCK-3530-2DP PCK-530-DP Operator s Manual and Installation Instructions Premium Supply 2038 West Interstate 30 866-934-0777 Proud members of: and June 20, 2018 Table of Contents

More information

OPERATION MANUAL. ALUMINUM Models DUCTILE Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

OPERATION MANUAL. ALUMINUM Models DUCTILE Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS OPERATION MANUAL 3 METALLIC PUMP (CLAMPED) PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF80 AIR-OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models DUCTILE Models 316 S.S. Models A JDA Global Company CAUTIONS - READ

More information

FLEX VANE IMPELLER MODEL 3000-XXX Replacement Parts Kit Instructions

FLEX VANE IMPELLER MODEL 3000-XXX Replacement Parts Kit Instructions FLEX VANE IMPELLER MODEL 3000-XXX Replacement Parts Kit Instructions WARNING:Do not pump flammable liquids! Model 3000 pumps (Buna impeller) are suitable for non-potable water, automotive oil, automatic

More information

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual Model GXR Series Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual Consumer Pump Horizontal/Vertical Pump with built-in Regulator, Thermal Relief Valve and Siphon Injector Updated

More information

STOP. Oil Pump Models L 5016, L 5116 & L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

STOP. Oil Pump Models L 5016, L 5116 & L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS SAVE THESE INSTRUCTIONS 5252 East 36th Street North Wichita, KS USA 67220-3205 TEL: 316-686-7361 FAX: 316-686-6746 Oil Pump Models L 5016, L 5116 & L 5132 Owner s Manual STOP DO NOT RETURN THIS PRODUCT

More information

Page 1 of 19. Part# /10/2006

Page 1 of 19. Part# /10/2006 Part# 1002733-01 10/10/2006 This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly and keep for future reference INSTRUCTIONS

More information

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL AL- Model Number Date Code / Serial Number Date of Purchase LIMITED WARRANTY ALITA warrants to the original retail consumer purchaser ( Customer ) that

More information

WARNING CAUTION. CAUTION Do not exceed 120 psig (8.3 bar) air-inlet pressure.

WARNING CAUTION. CAUTION Do not exceed 120 psig (8.3 bar) air-inlet pressure. 13966-100-BP SAFETY MANUAL READ FIRST! IMPORTANT: READ THESE WARNINGS AND SAFETY PRECAUTIONS PRIOR TO INSTALLATION OR OPER- ATION. FAILURE TO COMPLY WITH THESE INSTRUC- TIONS COULD RESULT IN PERSONAL INJURY

More information

Model CP420/CP425. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

Model CP420/CP425. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual Model CP420/CP425 Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual Updated 02/12 Contents: Installation Instructions: page 2 Pump Specifications: page 3 Exploded View: page

More information

#9040 FUEL TANK SWEEPER

#9040 FUEL TANK SWEEPER #9040 FUEL TANK SWEEPER INSTRUCTION MANUAL FILTERS AND REMOVES FINE BIO-CONTAMINANTS, ALGAE, ETC. SWEEPING PROCESS REMOVES LARGE CONTAMINANTS FROM OIL TANKS SUCH AS RUST, WATER, CRUDE AND DIRT CIRCULATES

More information

Installation and Operating Manual

Installation and Operating Manual Model u002 & u003 Installation and Operating Manual Ultrasonic Level Switch 60 Great Hill Road Naugatuck, CT 06770 ph: 203-729-6434 fax: 203-729-6696 www.innovativesensing.com Read this Manual Before Installing

More information

Model GP Triplex Ceramic Plunger Pump Operating Instructions/ Manual

Model GP Triplex Ceramic Plunger Pump Operating Instructions/ Manual Model GP6145-3100 Triplex Ceramic Plunger Pump Operating Instructions/ Manual Contents: Installation Instructions: page 2 Pump Specifications: page 3 Exploded View: page 4 Parts List / Kits: page 5 Repair

More information

COMPRESSED AIR LOADER MODEL: AL-1

COMPRESSED AIR LOADER MODEL: AL-1 COMPRESSED AIR LOADER MODEL: AL-1 Document: AL-1 IM 10-22-2011 TABLE OF CONTENTS Important Notices and Precautions 3 Quick Installation 4 Product Description 4 Principle of Operation 5 Unpacking and Inspection

More information

OPERATION MANUAL 2 POLYPROPYLENE PUMP DURA-FLO TM AIR DISTRIBUTION SYSTEM

OPERATION MANUAL 2 POLYPROPYLENE PUMP DURA-FLO TM AIR DISTRIBUTION SYSTEM OPERATION MANUAL 2 POLYPROPYLENE PUMP DURA-FLO TM AIR DISTRIBUTION SYSTEM CAUTIONS - READ FIRST CAUTION: Do not apply compressed air to the exhaust port pump will not function. CAUTION: Do not exceed 82

More information

MDP 1000 OPERATING INSTRUCTIONS PUMP MDP 1000 OPERATING INSTRUCTIONS

MDP 1000 OPERATING INSTRUCTIONS PUMP MDP 1000 OPERATING INSTRUCTIONS MDP 1000 OPERATING INSTRUCTIONS PUMP MDP 1000 OPERATING INSTRUCTIONS SAINT-GOBAIN PERFORMANCE PLASTICS FRANCE SAINT-GOBAIN PERFORMANCE PLASTICS EADAC DES BERTHILLIERS 7301 Orangewood Avenue F-71850 CHARNAY

More information

Stealth Power i-tilt

Stealth Power i-tilt Power Tilts OWNERS MANUAL Stealth Power i-tilt User Manual and Maintenance Guide for Stealth s i-tilt Customer Satisfaction 1.0 Stealth Products strives for 100% customer satisfaction. Your complete satisfaction

More information

PPM EO-100 TM. Operation Manual

PPM EO-100 TM. Operation Manual PPM EO-100 TM Open Loop Electric Prewet Power Module Operation Manual Rev A Page 1 2/23/2010 Copyright 2008 by Cirus Controls, LLC. All Rights Reserved. No part of this material may be reproduced in any

More information

Model 8329 Table of Contents

Model 8329 Table of Contents SERVICE & OPERATING MANUAL Original Instructions Instructions Sheet: 670991 Model 8329 Table of Contents Engineering Data and Temperature Limitations... 1 Performance Curve... 2 Dimensions... 3 Metric

More information

UV PROCESS SUPPLY, INC. CON-TROL-CURE ½ DIAPHRAGM PUMP INSTRUCTION MANUAL PART # J

UV PROCESS SUPPLY, INC. CON-TROL-CURE ½ DIAPHRAGM PUMP INSTRUCTION MANUAL PART # J 1 IMPORTANT: READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING. PUMP DATA TYPE: MAT'L: WEIGHT: Air Operated Double Diaphragm Polypropylene or PVDF or Acetal PVDF (Polyvinylidene Fluoride)

More information

OPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS .5 METALLIC PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 15

OPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS .5 METALLIC PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 15 OPERATION MANUAL.5 METALLIC PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 15 AIR-OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models 316 S.S. Models A JDA Global Company 2 CAUTIONS - READ FIRST CAUTION: Do not

More information

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL MODEL #VP05, VP10 C US NSF/ANSI 372 255405 For loose, missing or damaged parts, or if the unit does not seem to be operating properly, please call before returning

More information

INTRODUCTION INSTALLATION

INTRODUCTION INSTALLATION INTRODUCTION INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS This instruction manual includes installation, operation and maintenance information for the figure G73 gear operator. The figure G73 is

More information

OPERATING INSTRUCTIONS ZDX 1/12CS

OPERATING INSTRUCTIONS ZDX 1/12CS OPERATING INSTRUCTIONS ZDX 1/12CS www. sethco. com info@sethco.com INDEX Warranty 2 Safety Rules 3 Operating Instructio ns 4 General Description 4 Pre-installation 4 Pump Installation 4 Piping the Pump

More information

0.7 m 3 /h - 3 GPM D 07 RE 125 D 07 RE 5. owner s manual

0.7 m 3 /h - 3 GPM D 07 RE 125 D 07 RE 5. owner s manual 0.7 m 3 /h - 3 GPM D 07 RE 125 D 07 RE 5 owner s manual GB You have just become the owner of one of the latest in the line of DOSATRON proportional dosing pumps and we congratulate you on your choice.

More information

Instructions Parts List

Instructions Parts List Instructions Parts List ACETAL Husky 515 Air Operated Dual Inlet Diaphragm Pump Used to evacuate and transfer fluids. 100 psi (0.7 MPa, 7 bar) Maximum Fluid Working Pressure 100 psi (0.7 MPa, 7 bar) Maximum

More information