1 Vertical Chemical Pumps JKD/JKT/JKH/JKP/JKV Series Instruction Manual JIEKAI INDUSTRIAL EQUIPMENT CO., LTD. 0

2 1. Introduction Table of Contents Model Definition... 2 Specification And Suitable Applications... 2 Specification Table Installation Installation Dimension Announcements....7 Application Drawing Operating Procedure Preparation Before Operation. 10 Announcements Maintenance & Repair Preparation Announcements Maintenance & Repair Troubleshooting Using Announcements JKD/JKT/JKH/JKP Parts Drawing JKD Series Assembly Drawing JKT Series Assembly Drawing.13 JKP-1/8-1/6 Series Assembly Drawing 13 JKP-1/4-1/2 Series Assembly Drawing 13 JKH Series Assembly Drawing Warranty Data Card

3 1. Introduction JKD 40 SK 3 5 V F (1) (2) (3) (4) (5) (6) (7) (1) Model NO.:JKD/JKT/JKH-W/JKH/JKH-Y/JKP/JKP-W (2) Outlet Diameter:15-1/2", 20-3/4", 25-1", /2", 50-2", /2", 80-3", 100-4" (3) Specific Gravity: SK-1.1 SP-1.4 (4) Horse Power: 1/15HP, 1/8HP, 1/6HP, 1/4HP, 1/3HP, 1/2HP, 1HP, 2HP, 3HP, 5HP, 7.5HP, 10HP, 15HP (5) Frequency:5-50HZ 6-60HZ (6) O-ring: V-VITON E-EPDM (7) Pump Body Material:F-FRPP P-PVDF Character: 1. They are made of corrosion resistant material: FRPP/PVDF, appropriate for high temperature & corrosion resistant for chemical solution. As used in the special environment, please confirm from our company or our local distributors. 2. The impellers are specially designed to ensure efficient operation and high performance. 3. Sealless shaft structure would avoid from the friction fault in the operation of the pump, therefore, could not let the pump breakdown when idle or processing with particles in the liquid. 4. The main parts of the pump are of injection molding to assure the precision of the whole pumps. 5. The motor is with steam protection features to avoid from the corrosion by the chemical steam. 6. JKT/JKH/JKP series are equipped with special flexible angle part, it will be easy to use for long time maintenance. 7. JKP series adopt "C" shape retaining ring combination, the main part of entrance is designed for in-tank applications. 8. JKD series are flange design, mainly used for installation out of tank applications. Application: 1. If equipped with chemical liquid filter, could be used for any kinds of plating solution filter and circulation. 2. Used in the PCB production of the etching or circulation. 3. Circulation and recycling operations for scrubber processor system. 4. Used for heat exchanger conveying pump. 5. Processing, circulation and stirring for all kinds of chemical reaction tank and chemical fluid in the mixing drum. 6. Loop filtering operation for electrolyte less plating. 2

4 Specification Table (Testing Fluid:S.G. / Water Proportion:1.0) JKD Series Vertical Pump Out Of Tank JKT Series Vertical Pump Out Of Tank 3

5 JKH Series Vertical Pump Out Of Tank JKP Series Vertical Pump Out Of Tank 4

6 2. Installation Installation Dimension Drawing JKD Series JKT Series JKP-1/8-1/6 Series JKP-1/4-1/2 Series JKH Series Vertical Pumps In Tank 5

7 JKD Series Vertical Pumps Out Of Tank JKT Series Vertical Pumps Out Of Tank JKP Series Vertical Pump In Tank 6

8 Announcements: 1. Install the pumps on firm & horizontal ground to keep the pump body vertical and well-fixed. 2. Avoid installation outdoor. If needed, please cover with visor for protection. If equipped with electronic controller, need to particularly protect. 3. Choose different pipe material according to for the chemical liquid surrounding, temperature condition, processing head and capacity. 4. Pay attention to without any residual impurities or debris inside the pipe to prevent air suction pump when piping. 5. When piping please pay attention to the pipe without any distortion, after installation, check the pump body again. If there is any movement and distortion affected when overdrive installation or improper installation. 6. Flange joint shall be lined with gasket to assure it lock well to prevent air suction pump. 7. If the entrance must be equipped with bottom valve or check valve, it is needed to equip with the check valve on the outlet position lower than the motor. 8. For safety's sake, you'd better equip with inlet strainer to avoid any damage due to suction sundries. 9. Entrance connecting flange must be the same as the inlet flange diameter, outlet flange must be the same as outlet flange diameter. 10. After installation you should confirm whether the pipeline is fixed well and tightly to avoid damage caused by vibrations. 11. Before plug in the power cord, you should confirm whether the power supply is consistent with the motor voltage, and equip with over-current protection switch. 12. Please well noted the motor nameplate specification according to demanded pump motor voltage, you can found circuit. 13. In order to protect the pump lifetime from damage caused by reverse pressure and vapor pressure pump, please connect the flexible hose with end drain fitting of pump, the other end should be connected to spare slot. Warning: The flow performance and security will be affected if fixed too tight or too loose will affect, please make sure all nuts locked well, otherwise it will cause liquid leakage; but it will be easily damage affected due to falling off if fixed too tight. Please finish the installation some familiar technical personals. 7

9 Application Drawing 8

10 Heat Exchange Circulating Pump Reaction Tank And Filter Compressor Pumps Notes: 1. Outlet pipe height, if it higher than the height of electric motor or check valves, please install check valve in the front of outlet pipe of pumps, the level of installing check valve keeps not too higher than the top or highest water level. 2. For inlet safety s sake, we had better install strainer, which avoid sucking impurities that will make pumps damaged. (Size of strainer mesh above 5 times as diameter) 3. While running pumps in special environment, and need to install anti-explosion or pressure resisting anti-explosion electric motor, please negotiate with our company technician. 4. While running pumps in an environment with chemical gas, it s necessary to choose special handling motor with electric-shock safeguard paint. 5. While running two vertical pumps in the same time, it s not allow to use the same outlet or inlet pipe, which will reduce pumps working life and function, more worse is damaging pumps. 9

11 3. Operating Procedure 3.1 Preparation Before Operation 1. Before running the pump, please pay attention to the following factors: the fluid type, proportion of viscosity, temperature, gravity. 2. Examine and Confirm whether the motor steering is consistent with labeled note on the motor fan cover. 3. Check the inlet, outlet flange and screw gasket should be locked firmly. 4. Check the liquid flow direction, the turning of the blade is decided by with the polarity of the power supply, you could note the correct direction through the cooling fan at the top of the motor. 5. Please note that the pump and pipeline can t be any leakage in order to avoid being hurt or environment pollution while running. 6. Make sure to fill with liquid before the pump running. 3.2 Announcements 1. Pay attention to the inward and outward valve is open, fluid level should be appropriate. 2. Workers need to wear protective clothing, gloves masks glasses and other protective equipment, in order to avoid skin contact with liquid. 3. Check the safety protection measures, such as liquid level controller, current breaker and ON/OFF switch. 4. Different kinds of chemical mixed together will cause chemical reactions, even high heat affected and make the pump damaged, therefore, so do not use the same pump to transport different chemical solutions. 5. Check the exit of pipeline at first before operation, be sure to check whether the valve has been opened, the flow go with right way, the liquid of barrels is normal and any breakage in the pipeline. 6. Please check and make sure the protection switch, such as liquid level switch and overload protection switch, etc. function well. 7. Check exit flow, when the capacity is too small, please immediately shut down pumps, and check the pipeline. 8. Outlet pressure must be lower than 3.2kg/cm. 9. Based on explosion protection and high pressure, please contact with our company before ordering. 4. Maintenance & Repair 4.1 Preparation Announcements 1. Please be sure to shut off the power. 2. Switch off inlet and outlet, discharge the liquid in the pump. 3. Maintenance personnel should wear protective clothing, gloves masks glasses and other protective equipment, and to avoid. 4. Pump should be lay down after removed please, do not place the motor on the upright. 4.2 Maintenance & Repair 1. Check the bottom valve or inlet strainer to avoid any impurity blocking. 2. When the motor running, pay attention to whether there is a different normal noise. 3. Check if there is electricity leakage. 4. If equipped with check valve, confirm whether it functions well. 5. If los of crystalline stay in the pump, it should be disassembled, please dip and clean the impeller, pump body and front cover in acidic solution and reassamble, or keep the pump in the acidic liquid circulation, and then rinse off with clear water circulation. 10

12 5. Troubleshooting Failure Circumstan Solution ce The motor cannot be started Power Overload Flow Capacity Normal motor speed but can not transfer liquid Too much noise shaking while pump running Pump with leakage liquid Fasten Spares(screw or nut) is worn 1. Check breaker. Power variation cause circuit overload. 2. Check if loose for power connector, if power lack of phase. 3. Impeller and pump body seizure, need to replace spares. 4. Impeller locked, clean impurities. 1. Too big liquid specific gravity, wrong models selection. 2. Unstable pressure cause overload. 3. Make friction between impeller and pump body, reassembly. 1. Check if block in the inlet of strainer. 2. Check if impurities locked in impeller. 3. Diameter of inlet pipe is too small. 4. Check outlet if block. 5. Motor diversion is opposite. 6. Motor speed is low. Check voltage if correct. 7. Check outlet or inlet ball valve if completely open. 1. Close outlet or inlet valve, open ball valve. 2. Air input into inlet. Check inlet pipe. 3. Too low inlet liquid level, which cause lack of liquid inside pump, supply liquid. 1. Worn motor bearing, replace bearing. 2. Motor spindle shaft is bend, replace motor spindle shaft. 3. Bearing housing is bend, replace bearing housing. 4. Impurities fill inside impeller or pump, dismount pump and clear it. 1. Replace O-ring. 2. While meeting liquid leakage during working, we should need to check outlet if block, which cause too big outlet pressure. If meeting liquid leakage while stop running pumps, we should need to check inlet if block, or need to consider if install check valve in front of outlet. 1. Replace fasten spares. 2. Replace chemical resisting fasten spares. (Such as PP, PVC, PPS, Titanium). 11

13 6. Using Announcements 1. While running pumps, prohibit arbitrarily changing chemical properties, because mixing different chemical properties will produce different chemical change, even chemical reaction will produce high heat, which damage pump itself. 2. Many chemical properties are seriously hurt human body, operator should try to avoid this dangerous area. 3. Before starting power, we should check the pipe and valve location if correct, power on if correct, at the same time, check liquid if discharge normally. 4. Transferring dangerous liquid under abnormal operation condition, such as outlet or inlet is close, pump selecting models is wrong, operation in idle, wrong pipe materials, which will produce serious danger, especially in idle process, which will make liquid inside pumps produce high temperature and gasify, some chemical properties includes hydrogen, which will seriously cause gas explosion and hydrogen explosion, we should specially notice it while operating. 5. Confirm outlet flow capacity while running pumps, if you find the outlet flow capacity is too small, we should shut down the pumps, and check the pipe if block. 6. Running under especial environment, and need safe explosion proof or pressure resisting explosion proof motor, please contact with our company technician. 7. Running under filled with chemical gas, we must select special handling motor with corrosion resistant paint. 8. Any misuse such as overpressure, self replace spares, mismatch chemical properties or using worn spares will produce serious dangerous condition, please follow safety warning. 9. Resisting temperature of all kind of materials as below: CFRPP:0-75 FRPP:0-75 CPVC: 0-75 PVDF: We should well know pumps operation before researching problems, please carefully read this user manual, even all unit parts installation, this manual with sufficient instruction. 11. While transferring dangerous liquid or locate in dangerous environment, please wear safeguard glove and glass. 12

14 7. JKD/JKT/JKH/JKP Parts Drawing JKD JKT JKP-1/4-1/2 JKP-1/8-1/6 13

15 14 JKH

16 8. Warranty Date Card 15

WET/DRY RUNNING INTANK VERTICAL CANTILEVER SEALLESS PUMPS TFV / TFO / TFP SERIES TI TOWN CHEMICAL PUMPS

WET/DRY RUNNING INTANK VERTICAL CANTILEVER SEALLESS PUMPS TFV / TFO / TFP SERIES TI TOWN CHEMICAL PUMPS WET/DRY RUNNING INTANK VERTICAL CANTILEVER SEALLESS PUMPS TFV / TFO / TFP SERIES TI TOWN CHEMICAL PUMPS INTANK VERTICAL CANTILEVER SEALLESS CHEMICAL PUMPS CHEMICAL & HEAT RESISTANT NO SEAL NO FRICTION

More information

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

SLR / SLR-S/N. Instruction Manual. Walrus America Inc SLR / SLR-S/N Instruction Manual Walrus America Inc 1. Installation and Connection 1.1. Pump Installation The pump should be sited in a well ventilated and frost-free position. The distance between pumps-motors

More information

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY PRODUCT OVERVIEW The VADA V75-S submersible pumps are suitable for installation in traditional wells, water deposits, collection tanks, clear watercourses, lakes etc. The V75-S provides a hydraulic system

More information

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS Model 31801 and 31800 Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS INDUSTRIAL DIAPHRAGM PUMPS FEATURES Run Dry Ability Self-Priming Thermal Overload Protected Motor Easy Installation Low Amp Draw Compact

More information

PL Submersible, Semi-Vortex, Water Feature Pump

PL Submersible, Semi-Vortex, Water Feature Pump TM M 2001992 Introduction Submersible, Semi-Vortex, Water Feature Pump This manual provides information and procedures to safely install, operate and maintain this TSURUMI model. For your own safety and

More information

1/2 HP SUMP PUMP OWNER'S MANUAL

1/2 HP SUMP PUMP OWNER'S MANUAL TM 1/2 HP SUMP PUMP OWNER'S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious

More information

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories. Be sure to thoroughly read and understand the SAFETY PRES given in this section before using the equipment in order to operate the equipment correctly. The precautionary measures described in this section

More information

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery Table 6-1. and solutions with pump operations No Fluid Delivery Fluid level in the reservoir is low. Oil intake pipe or inlet filter is plugged. Air leak in the inlet line prevents priming or causes noise

More information

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP Model 54011-0 OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP Questions, problems, missing parts? Before returning to the store call AQUAPRO Customer Service 8 a.m. - 5 p.m., EST, Monday-Friday 1-844-242-2475

More information

Plunger Heads Use and Maintenance Manual

Plunger Heads Use and Maintenance Manual Plunger Heads Use and Maintenance Manual UK Positive displacement dosing pump Type PDP Series A-I 175 A-I 250 A-I 350 General instructions We thank you for choosing this product and recommend you read

More information

440/880LB ELECTRIC HOIST STF-4488EH

440/880LB ELECTRIC HOIST STF-4488EH ELECTRIC HOIST 440/880LB WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result

More information

Submersible Pump Instructions. Safety Instructions

Submersible Pump Instructions. Safety Instructions Submersible Pump Instructions Safety Instructions Before operating of this pump, read this manual and follow all safety rules and operating instructions. Before operating of this pump, read this manual

More information

GL Ludemann Y-Strainers

GL Ludemann Y-Strainers GL Ludemann Y-Strainers Installation, Operation and Maintenance Manual English Issue 1-03/2014 - Page 1/7 GENERAL These instructions are for installing, operation and maintenance of Y-strainers fabricated

More information

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY PRODUCT OVERVIEW The VADA series of self priming jet pumps combine the functional benefits of centrifugal pumps and the practical and qualitative benefits of self-priming pumps. The Venturi system the

More information

PRODUCT: 1500 SERIES MOBILE EXPLOSION PROOF PAGE 1 REV "BLADE MASTER" AC-EP-SINGLE PHASE-1.5 HP OPERATING AND MAINTENANCE INSTRUCTIONS

PRODUCT: 1500 SERIES MOBILE EXPLOSION PROOF PAGE 1 REV BLADE MASTER AC-EP-SINGLE PHASE-1.5 HP OPERATING AND MAINTENANCE INSTRUCTIONS PRODUCT: 1500 SERIES MOBILE EXPLOSION PROOF PAGE 1 REV.020112 "BLADE MASTER" AC-EP-SINGLE PHASE-1.5 HP OPERATING AND MAINTENANCE INSTRUCTIONS The "Blade Master is a high-volume, low-energy, (U.L. /C.S.A.,

More information

OWNER S MANUAL STOP. Models: Blade Master 1.5 HP 1500 Series Stationary Transfer Pump 1.5 Pump, Single Phase AC 110/220V, Non-Explosion proof

OWNER S MANUAL STOP. Models: Blade Master 1.5 HP 1500 Series Stationary Transfer Pump 1.5 Pump, Single Phase AC 110/220V, Non-Explosion proof SAVE THESE INSTRUCTIONS Models: 02-1514-GII, 02-1520-GII, 02-1521-GII, 02-1522-GII Blade Master 1.5 HP 1500 Series Stationary Transfer Pump 1.5 Pump, Single Phase AC 110/220V, Non-Explosion proof OWNER

More information

GENERAL WARNING. General instructions. Technical assistance. Doseuro S.r.l. Liability

GENERAL WARNING. General instructions. Technical assistance. Doseuro S.r.l. Liability Diaphragm interposed fluid head Use and maintenance manual Model Model BR Model UK Positive displacement metering pump PDP Series Type B I 250 I 350 SD GENERAL WARNING General instructions We thank you

More information

USER S GUIDE FOR AUTO TRANSMISSION FLUID

USER S GUIDE FOR AUTO TRANSMISSION FLUID USER S GUIDE FOR AUTO TRANSMISSION FLUID HO-211 This manual was prepared in November, 2002. The product specifications contained in this manual are subject to change without prior notice. Contents Chapter

More information

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP Model 51101-0 OWNER S MANUAL SUBMERSIBLE UTILITY PUMP Questions, problems, missing parts? Before returning to the store call AQUAPRO Customer Service 8 a.m. - 5 p.m., EST, Monday-Friday 1-844-242-2475

More information

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

Air Operated Diaphragm Pumps Operating and Maintenance Instructions Product & Chemical Disclaimer The user must take responsibility in the selection of the products materials of construction. Empire Pumps Ltd will act in an advisory role and offer recommendations; however,

More information

Installation, operation and maintenance manual

Installation, operation and maintenance manual Installation, operation and maintenance manual HCT1LX30 FULL RISE SCISSOR LIFT READ THIS ENTIRE MANUAL BEFORE INSTALLATION TO ENSURE CORRECT OPERATION AND A LONG SERVICE LIFE 2 Tiraines str. Riga, LV 1058

More information

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-40 RX-63 RX-100

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-40 RX-63 RX-100 V acuum Pumps Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-40 RX-63 RX-100 www.republicsales.com Revised 02.15 2015 Republic Sales & Manufacturing Single Stage Rotary Vane

More information

10A / 15A / 20A Solar Charge Controller. PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL

10A / 15A / 20A Solar Charge Controller. PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL 10A / 15A / 20A Solar Charge Controller PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL Dear Customer, Thank you very much for choosing our product. This manual contains important information about

More information

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER SPECIFICATIONS: *Photo for reference only* Part number 8890439 Mode Select: Selects Battery Type Refer to Section 6. IMPORTANT: READ

More information

INSTRUCTION AND REPAIR MANUAL MODELS 341A, 342A AND 344A 6

INSTRUCTION AND REPAIR MANUAL MODELS 341A, 342A AND 344A 6 SECTION 6 ITEM 0 DATED JUNE 1998 SUPERSEDES ITEMS 1, 2, DATED MARCH 1992 INSTRUCTION AND REPAIR MANUAL MODELS 1A, 2A AND A 6 NOTE This repair manual is applicable to pump Models 1A, 2A and A. All photos

More information

SANITARY SELF PRIMING PUMP Manual

SANITARY SELF PRIMING PUMP Manual JONENG VALVES CO.,LIMITED SANITARY SELF PRIMING PUMP Manual JONENG VALVES CO.,LIMITED Technical principle Qty. Parameter Unit Dynamic viscosity factor μ mpa.s (=cp=centipoise) Viscosity V=μ/ρ With ρ=specific

More information

SUBMERSIBLE MAGNETIC DRIVE PUMP SUBMERSIBLE YD-5002GWN. INSTRUCTION MANUAL Version: (for U.S.A)

SUBMERSIBLE MAGNETIC DRIVE PUMP SUBMERSIBLE YD-5002GWN. INSTRUCTION MANUAL Version: (for U.S.A) SUBMERSIBLE MAGNETIC DRIVE PUMP SUBMERSIBLE YD-5002GWN INSTRUCTION MANUAL Version: 20110510 (for U.S.A) PREFACE Thank you very much for purchasing World Chemical s improved magnetic drive pump Submersible.

More information

AU DU PONT DE LUTTRE BRUSSELS BELGIUM PHONE: FAX: OPERATING MANUAL. Electric Fully Automatic Floor Saw FS 1218 EX

AU DU PONT DE LUTTRE BRUSSELS BELGIUM PHONE: FAX: OPERATING MANUAL. Electric Fully Automatic Floor Saw FS 1218 EX AU DU PONT DE LUTTRE 74-1190 BRUSSELS BELGIUM PHONE: 322 34 83 162 FAX: 322 34 83 136 OPERATING MANUAL Electric Fully Automatic Floor Saw FS 1218 EX 2 Important information before you start! When the machine

More information

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25 V acuum Pumps Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25 www.republicsales.com Revised 10.14 2014 Republic Sales & Manufacturing Single Stage Rotary Vane Vacuum

More information

OPERATION & MAINTENANCE MANUAL HANGZHOU FLYING TECHNOLOGY CO., LTD.

OPERATION & MAINTENANCE MANUAL HANGZHOU FLYING TECHNOLOGY CO., LTD. CENTRIFUGAL PUMP ZPD6-25*7 OPERATION & MAINTENANCE MANUAL HANGZHOU FLYING TECHNOLOGY CO., LTD. CONTENTS 1. GENERAL (1) 2. NOMENCLATURE OF THE TYPE (1) 3. MAIN TECHNICAL SPECIFICATIONS RANGE (1) 4. STANDARD

More information

Ph: (07) Fax: (07) Pump Manual

Ph: (07) Fax: (07) Pump Manual sales@scintex.com.au www.scintex.com.au Ph: (07) 3137 0135 Fax: (07) 3041 0541 Pump Manual 12V 75LPM Vane Pump & Vane Pump Station SPEP12V75 & SP12VFS75 SPEP12V75 SP12VFS75 Parts List No. Part Name QTY

More information

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-630

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-630 V acuum Pumps Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-630 www.republicsales.com Revised 02.15 2015 Republic Sales & Manufacturing Single Stage Rotary Vane Vacuum Pump

More information

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Contents Section 1. General Observations... 2 2. Operation... 4 3. Control During Operation... 5 4. Trouble Shooting... 6 5. Maintenance... 7 Please

More information

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air ORIGINAL INSTRUCTIONS Form No.1000458 5 SPX Corporation 5885 11th Street Rockford, IL 61109-3699 USA Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031 Internet

More information

- click here for pricing and ordering

- click here for pricing and ordering www.pumpagents.com - click here for pricing and ordering No. 51-038 Mar. 01, 2006 MD-40R MD-40RX MD-40RZ(-5) Item Description Q'ty Material Part No. Part No. Part No. 1 Front Casing Unit 1 GFRPP+PTFE MD0053

More information

End Suction Centrifugal

End Suction Centrifugal M o d e l s 3 U / 3 U B End Suction Centrifugal Operating Instructions, Installation & Maintenance Manual Certified to NSF/ANSI 6, ANNEX G * NSF/ANSI 6 Annex G listed models: 3U EBARA International Corporation

More information

KNAPSACK ELECTRIC SPRAYER

KNAPSACK ELECTRIC SPRAYER KNAPSACK ELECTRIC SPRAYER Applicable Models SFESR-6A-0 SFESR-6B-0 SFESR-20A-0 SFESR-20B-0 FUAN AIDI ELECTRIC CO., LTD Add: No. Road 6, Qinxiyang Industry Area, Fuan, Fujian, China Tel: 0086 592 5930656

More information

Installation and Maintenance Manual

Installation and Maintenance Manual Installation and Maintenance Manual WorldWide Helical Inline Speed Reducers This operation manual includes important information for the installation, assembly, operation and maintenance of the WorldWide

More information

SERIES OPERATION AND MAINTENANCE MANUAL

SERIES OPERATION AND MAINTENANCE MANUAL SERIES OPERATION AND MAINTENANCE MANUAL This manual CONTAINS IMPORTANT WARNINGS, S and OTHER INSTRUCTIONS. Read and understand the instruction manual Carefully, before use and retain it for reference.

More information

GMZ series Slurry Pump

GMZ series Slurry Pump GMZ series Slurry Pump OPERATION MANUAL HL Mud Cleaning Equipment Co.,Ltd Contents 1. Summarizing 2. Structural Drawing 3. Technical Parameters 4. Points for attention for assembly 5. Operation 6. Care

More information

Lynx 3:1 Pump. Model: OPERATION, INSTALLATION, MAINTENANCE AND REPAIR GUIDE

Lynx 3:1 Pump. Model: OPERATION, INSTALLATION, MAINTENANCE AND REPAIR GUIDE SERVICE BULLETIN SB1101 Revision F 10/13 Lynx 3:1 Pump Model: 1110-007 Thoroughly read and understand this manual before installing, operating or servicing this equipment. OPERATION, INSTALLATION, MAINTENANCE

More information

EP1306N 5 Gallon Can Extruder System Rev. A June EP1306N Operation Manual

EP1306N 5 Gallon Can Extruder System Rev. A June EP1306N Operation Manual EP1306N Operation Manual 1 THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK 2 TABLE OF CONTENTS SECTION 1: SAFETY... 4 1. GENERAL SAFETY... 5 2. PUMP SAFETY... 5 3. FLUID PRESSURE AND COMPATIBILITY... 6 4.

More information

Three Lobes Roots Blower. Instruction Manual

Three Lobes Roots Blower. Instruction Manual Three Lobes Roots Blower Instruction Manual Welcome to purchase the three lobes roots blower produced by us. You shall read this instruction manual seriously before you use this product in order to ensure

More information

GRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions

GRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions GRUNDFOS INSTRUCTIONS MTC Installation and operating instructions LIMITED WARRANTY Products manufactured by GRUNDFOS PUMPS CORPORATION (Grundfos) are warranted to the original user only to be free of defects

More information

Heavy Duty Engine Cranes

Heavy Duty Engine Cranes Heavy Duty Engine Cranes Operating Instructions & Parts Manual Model Number ATD-7484 ATD-7485 (Foldable Legs) Capacity 2 Ton 2 Ton Model ATD-7484 Model ATD-7485 WARNING: This product may contain chemicals,

More information

LS0512 Solar Charge Controller

LS0512 Solar Charge Controller LandStar LS0512 Solar Charge Controller Nominal system voltage Maximum PV input voltage Nominal charge / discharge current 12VDC 35V 5A Contents 1 Important Safety Information... 1 2 General Information...

More information

MANUAL APPQO-HP2. For 100L and 200L Open Drum Can Air Type Vacuum Cleaner. Contents:

MANUAL APPQO-HP2. For 100L and 200L Open Drum Can Air Type Vacuum Cleaner. Contents: For 100L and 200L Open Drum Can Air Type Vacuum Cleaner MANUAL APPQO-HP2 Contents: 2 For Safety 2 ~ 5 Before the use 5 Operation Conditions How to use and to stop 6 Trouble Shooting Filter Maintenance

More information

Submersible Mixed Flow/Axial Flow Pump Model SAM Model SPM

Submersible Mixed Flow/Axial Flow Pump Model SAM Model SPM Instruction Manual Installation Manual Submersible Mixed Flow/Axial Flow Pump Model SAM Model SPM Thank you for your purchase of the Submersible Mixed Flow/Axial Flow Pump. Teral s Submersible Mixed Flow/Axial

More information

Safety Precautions. Please be sure to closely follow all safety precautions and warnings. Danger. Warning. Caution

Safety Precautions. Please be sure to closely follow all safety precautions and warnings. Danger. Warning. Caution Contents Specifications...4 List of Contents...4 Installation Instructions...5 Operating Instructions...6 Maintenance Instructions...7 Warranty Provisions...9 Disposal Method...9 Safety Precautions Please

More information

Sediment strainer (Type Y)

Sediment strainer (Type Y) Installation,Operation and Maintenance Manual Serial No. H-V034-E-9 Sediment strainer (Type Y) Contents (1) Be sure to read the following warranty clauses of our product 1 User s Manual (2) General operating

More information

WARNING Carefully Read These Instructions Before Use

WARNING Carefully Read These Instructions Before Use DO NOT RETURN THIS SPRAYER TO STORE Call: 1-800-950-4458 Backpack Sprayer Use and Care Manual Manufactured for Northern Tool + Equipment Co., Inc. WARNING Carefully Read These Instructions Before Use Model

More information

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart Instruction & Parts Manual This Manual Covers P/N 33271 P/N 33271

More information

1 MECHANICAL FUEL METER

1 MECHANICAL FUEL METER 1 MECHANICAL FUEL METER USER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious

More information

SUBMERSIBLE MINI-PUMP

SUBMERSIBLE MINI-PUMP SUBMERSIBLE MINI-PUMP Model 41287 Set up And Operating Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from

More information

150 Gallon 3- Point Hitch Sprayer

150 Gallon 3- Point Hitch Sprayer 150 Gallon 3- Point Hitch Sprayer Model #: K3PTH150BN22 User Manual Read this manual for complete instructions Model #: K3PTH150BN22 Table of Contents Warranty... 3 General Safety Information... 3 Hazardous

More information

Mounting and Operating Instructions EB 8091 EN. Pneumatic Control Valve Type and Type Type with 120 cm 2 actuator

Mounting and Operating Instructions EB 8091 EN. Pneumatic Control Valve Type and Type Type with 120 cm 2 actuator Pneumatic Control Valve Type 3510-1 and Type 3510-7 Type 3510-1 with 120 cm 2 actuator Type 3510-7 with 120 cm 2 actuator and integrated positioner Type 3510-1 with 60 cm 2 actuator Fig. 1 Pneumatic control

More information

Heavy Duty Engine Cranes

Heavy Duty Engine Cranes Heavy Duty Engine Cranes Operating Instructions & Parts Manual Model Number Atd-7484 Atd-7485 (Foldable Legs) Capacity 2 Ton 2 Ton Model Atd-7484 Model Atd-7485 Atd Tools Inc. 160 Enterprise Drive, Wentzville,

More information

MP3450I Battery Bank Instruction (V1.0)

MP3450I Battery Bank Instruction (V1.0) MP3450I Battery Bank Instruction (V1.0) Catalogue General (3) Unpacking (3) Function (4 Illustration 5) Charging (5 Instruction 6) Operation (6 Guide 7) Extra (7 battery Illustration 8) Function Instruction

More information

ELECTRIC LIFTER TROLLEY INSTRUCTION MANUAL

ELECTRIC LIFTER TROLLEY INSTRUCTION MANUAL ELECTRIC LIFTER TROLLEY INSTRUCTION MANUAL Imported exclusively by Pacific Hoists Pty. Ltd. & Pacific Hoists Ltd. In support of cancer charities in Australia & New Zealand 2 www.jbstools.com WWW.CHALLENGERHOISTS.COM.AU

More information

USE and MAINTENANCE INSTRUCTION MANUAL AZ3 HTE2 AZ3 HTE2 HVLP GRAVITY. SPRAY GUN Series. en it fr es pt de se

USE and MAINTENANCE INSTRUCTION MANUAL AZ3 HTE2 AZ3 HTE2 HVLP GRAVITY. SPRAY GUN Series. en it fr es pt de se USE and MAINTENANCE INSTRUCTION MANUAL AZ3 HTE2 AZ3 HTE2 HVLP GRAVITY SPRAY GUN Series en it fr es pt de se TECHNICAL DATA Technical AZ3 HTE2 AZ3 HTE2 HVLP 1.0 80 180 1.3 10-15HTE 140 200 240 1.5 2.0 160

More information

50:1 Grease Pump Kits

50:1 Grease Pump Kits TM INS680A Published: 6/0/00 Revised 7/8/06 50: Grease Pump Kits Models L680A Read the following precautions and instructions before you begin assembly or using. Failure to comply with these instructions

More information

3.5 CUbIC feet portable CEMENT MIxER 02/2015 INSTRUCTION MANUAL MODEL: KC-15CM-2 COPYRIGHT 2014 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC.

3.5 CUbIC feet portable CEMENT MIxER 02/2015 INSTRUCTION MANUAL MODEL: KC-15CM-2 COPYRIGHT 2014 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC. 3.5 CUbIC feet portable CEMENT MIxER 02/2015 MODEL: KC-15CM-2 INSTRUCTION MANUAL COPYRIGHT 2014 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC. WARRANTY INfORMATION 2-YEAR LIMITED WARRANTY FOR THIS CEMENT

More information

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories. Be sure to thoroughly read and understand the SAFETY PRES given in this section before using the equipment in order to operate the equipment correctly. The precautionary measures described in this section

More information

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM Performance Model HP GPH of Water @ Total Feet Of Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. 25 ft. Max. Lift SUNC1200

More information

INSTRUCTIONS Your Ampco centrifugal pump is a rugged unit designed to provide years of low cost pumping service. There is a small amount of necessary care required to ensure you of this expected long service.

More information

18- G A L L O N O I L D R A I N D O L LY OWNER S MANUAL

18- G A L L O N O I L D R A I N D O L LY OWNER S MANUAL 18- G A L L O N O I L D R A I N D O L LY OWNER S MANUAL WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic

More information

Ver Trunnion Ball Valve INSTALLATION, OPERATION AND MAINTENANCE MANUAL FBV/IOM/BA02

Ver Trunnion Ball Valve INSTALLATION, OPERATION AND MAINTENANCE MANUAL FBV/IOM/BA02 Ver. 2008 Trunnion Ball Valve INSTALLATION, OPERATION AND MAINTENANCE MANUAL FBV/IOM/BA02 TABLE OF CONTENTS 1 APPLICATIONS...2 1.1 Applications...2 1.2 Performance Specifications...2 2 APPLICABLE STANDARDS...2

More information

High Vacuum Diaphragm-Type Dry Vacuum Pump

High Vacuum Diaphragm-Type Dry Vacuum Pump No 腄 26300-2-02-3 High Vacuum Diaphragm-Type Dry Vacuum Pump DTC-120 DTC-120A, 120B, 120C (According to CE) Request to Users Please read this manual thoroughly to ensure safe and effective use of the equipment.

More information

IS7.6 INSTALLATION MANUAL

IS7.6 INSTALLATION MANUAL IS7.6 INSTALLATION MANUAL #12501 MIN. 13.5" 1" 1" 29-7/8" 3" 14-7/8" 3" 20-7/8" 29-7/8" 24-5/8" Fig. 1 1 2 Fig. 2 Fig. 3 MAX. 80" MIN. 12" IS7.6 MIN. 8" Fig. 4 2 MIN. 6" MIN. 13.5" MIN. 12" MIN. 6" MIN.

More information

DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION:

DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION: DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION: These instructions are provided to familiarize the user with the seal and its use. The instructions must be read carefully

More information

Pug Mill NRA-04 NRA-04S

Pug Mill NRA-04 NRA-04S 91345B Pug Mill Instruction Manual NRA-04 NRA-04S Please make sure to read the entire instruction manual thoroughly before initial set-up, operation, maintenance and inspection to ensure proper use. Please

More information

Operating Instructions

Operating Instructions Operating Instructions BE2700 Brinkmann Immersions pumps of the series TA/STA/TAL/SAL901... 1303 Contents 1 General...1 2 Safety...2 3 Transport and storage...2 4 Description of product and accessories...2

More information

Starting up hydraulic systems

Starting up hydraulic systems General / Installation A hydraulic system that operates economically, safely, and trouble-free requires careful planning, as well as proper installation and start-up. Conscientious maintenance has a considerable

More information

Maintenance Information

Maintenance Information 16573347 Edition 2 February 2014 Air Grinder Series 88H Maintenance Information Save These Instructions Product Safety Information WARNING Failure to observe the following warnings, and to avoid these

More information

OPERATION MANUAL TSURUMI MANUFACTURING CO., LTD.

OPERATION MANUAL TSURUMI MANUFACTURING CO., LTD. 17236733/B-10011-5 LSC Submersible Residue Dewatering Pump LSP Self-Priming Residue Dewatering Pump OPERATION MANUAL TSURUMI MANUFACTURING CO., LTD. INTRODUCTION Thank you for selecting the Tsurumi LSC

More information

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5 MODELS 282050, 282716 & 283513 AIR OPERATED CHASSIS PUMP SERIES A OWNER/OPERATOR MANUAL SPECIFICATIONS Airmotor effective dia. in. 2.5 Airinlet Material outlet 1/4 NPTF 1/4 NPTF Liquid to Air Pressure

More information

Agxcel GX12i Chemical Injection System

Agxcel GX12i Chemical Injection System Agxcel GX12i Chemical Injection System Table of Contents System Contents... 3 Specifications... 4 Safety Precautions and Tips... 5 Operations... 6 Installation... 7 Maintenance... 8-9 Troubleshooting...

More information

MODEL CJ-95 CoilJet Portable HVAC Coil Cleaning System

MODEL CJ-95 CoilJet Portable HVAC Coil Cleaning System MODEL CJ-95 CoilJet Portable HVAC Coil Cleaning System OPERATING AND MAINTENANCE INSTRUCTIONS CJ-95 Manual 2009 All Rights Reserved 07/2009 Table of Contents Warranty... 1 Important Safety Instructions...

More information

DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION:

DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION: DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION: These instructions are provided to familiarize the user with the seal and its use. The instructions must be read carefully

More information

OPERATION INSTRUCTIONS GFA-W-150\300\500\1000

OPERATION INSTRUCTIONS GFA-W-150\300\500\1000 OPERATION INSTRUCTIONS HORIZONTAL SELF-SUCTION FILLER SERIES GFA-W-10\300\00\1000 Please operate in accordance with the instructions strictly. CONTENTS Overview Maintenance and Service Application Replacement

More information

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps EI-700-008 Rev -- Table of Contents Safety Guidelines 3 Caution 4 Wiring 4 Maintenance 4 Nameplate format 4 Prior to Operation

More information

#9040 FUEL TANK SWEEPER

#9040 FUEL TANK SWEEPER #9040 FUEL TANK SWEEPER INSTRUCTION MANUAL FILTERS AND REMOVES FINE BIO-CONTAMINANTS, ALGAE, ETC. SWEEPING PROCESS REMOVES LARGE CONTAMINANTS FROM OIL TANKS SUCH AS RUST, WATER, CRUDE AND DIRT CIRCULATES

More information

Dust cover. Plug. Outlet. Wire pole holder

Dust cover. Plug. Outlet. Wire pole holder Thank you for choosingxtreme machine,baby -Mammoth (4 head), designing with double gear-driving, planetary grinding with four plates. The machine speed can reach 1800 rpm. Aluminum alloy gear box with

More information

582 Series. Instruction Manual. Two-Door Wafer Check Valve N-582 (R-08/2016)

582 Series. Instruction Manual. Two-Door Wafer Check Valve N-582 (R-08/2016) 582 Series Two-Door Wafer Check Valve Instruction Manual N-582 (R-08/2016) Instructions These instructions provide installation, operation and maintenance information for Cla-Val 582 Series. They are for

More information

110 Volt/12 Volt Portable Inflator

110 Volt/12 Volt Portable Inflator 110 Volt/12 Volt Portable Inflator Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety

More information

1600 PSI ELECTRIC PRESSURE WASHER

1600 PSI ELECTRIC PRESSURE WASHER MODEL NO.: XE03 SKU: 39-8508-6 1600 PSI ELECTRIC PRESSURE WASHER Owner s Manual QUESTIONS, PROBLEMS, MISSING PARTS? Before returning to your retailer, visit our web site or call our customer service at

More information

END SUCTION CENTRIFUGAL PUMPS

END SUCTION CENTRIFUGAL PUMPS OWNERS GUIDE TO INSTALLATION AND OPERATION END SUCTION CENTRIFUGAL PUMPS FW000 0 Supersedes 009 READ THESE INSTRUCTIONS CAREFULLY Read these installation instructions in detail before installing your pump.

More information

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

SPECIFY THE RIGHT HOT OIL PUMP FOR YOUR APPLICATION

SPECIFY THE RIGHT HOT OIL PUMP FOR YOUR APPLICATION SPECIFY THE RIGHT HOT OIL PUMP FOR YOUR APPLICATION Hot oil pumps are used in a range of industries, with their main user being the heat transfer oil customer. Often, oil temperatures will exceed 500 F

More information

Foreword

Foreword Foreword Content 1. Summary 2. Safety instruction Safety Symbol Indication Attention Static discharge sensitive Electric shock Dangerous Indicate risk of serious injury or death or seriously damage the

More information

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009 HOT WASHER MODEL NO: KING 125 PART NO: 7320170 OPERATION & MAINTENANCE INSTRUCTIONS LS1009 INTRODUCTION Thank you for purchasing this Hot Washer. This machine is a portable, high pressure power washer,

More information

1/2" AIR DRIVEN DIAPHRAGM PUMP

1/2 AIR DRIVEN DIAPHRAGM PUMP 1/2" DRIVEN DIAPHRAGM PUMP OPERATION AND SERVICE GUIDE O-1225D NOV. 2008 Page 1 of 6 Refer to Bulletin P-605, Parts List P-9151 DRIVEN, DOUBLE DIAPHRAGM PUMP MANUAL Congratulations on purchasing one of

More information

12V Oil Extractor Pump

12V Oil Extractor Pump 12V Oil Extractor Pump Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions

More information

STRUT SPRING COMPRESSOR

STRUT SPRING COMPRESSOR OWNER S MANUAL PRODUCT CODE: 1221T STRUT SPRING COMPRESSOR Capacity Stroke Spring Coil Spring Spring Coil Net Weight (Maximum) Thickness Length Diameter 1,000kg 330mm 10-18mm 210-570mm 100-158mm 36kg Made

More information

0.7 m 3 /h - 3 GPM D 07 RE 125 D 07 RE 5. owner s manual

0.7 m 3 /h - 3 GPM D 07 RE 125 D 07 RE 5. owner s manual 0.7 m 3 /h - 3 GPM D 07 RE 125 D 07 RE 5 owner s manual GB You have just become the owner of one of the latest in the line of DOSATRON proportional dosing pumps and we congratulate you on your choice.

More information

NILFISK BA 500 Service Manual

NILFISK BA 500 Service Manual NILFISK BA 500 Service Manual Model 66324400 12/94 Form Number 043023 TABLE OF CONTENTS Batteries...21 Brush Drive Belt Adjustment Or Replacement...7 Brush Drive Motor - Carbon brush Inspection... 8 Brush

More information

Polypropylene Piston Drum Pumps

Polypropylene Piston Drum Pumps Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

INSTRUCTION MANUAL INDUSTRIAL PERISTALTIC PUMPS MODEL RBT-70

INSTRUCTION MANUAL INDUSTRIAL PERISTALTIC PUMPS MODEL RBT-70 INSTRUCTION MANUAL INDUSTRIAL PERISTALTIC PUMPS MODEL RBT-70 This manual forms an integral part of the pump and must accompany it until its demolition. The series FMP peristaltic pump is a machine destined

More information

LS0512R Solar Light Controller

LS0512R Solar Light Controller LandStar LS0512R Solar Light Controller Nominal system voltage Maximum PV input voltage Nominal charge / discharge current 12VDC 35V 5A Contents 1 Important Safety Information... 1 2 General Information...

More information

INSTRUCTION MANUAL (original instructions) K2, K3

INSTRUCTION MANUAL (original instructions) K2, K3 IMPORTANT DOCUMENT Please pass to Maintenance Department MDM PUMPS LTD Spring Lane Malvern Worcs WR14 1BP England Tel: +44 (0)1684 892678 Fax: +44 (0)1684 892841 E-mail: info@mdmpumps.co.uk www.mdmpumps.co.uk

More information