Sealweld Sales, Services and Training Saving clients Billions by preventing costly shutdowns and prolonging Valve and Actuator life since 1969
|
|
- Clifton Lambert
- 6 years ago
- Views:
Transcription
1 Sealweld Sales, Services and Training Saving clients Billions by preventing costly shutdowns and prolonging Valve and Actuator life since 1969 Presented By: Ward Hruza Branch Manager Houston, TX
2 Knowledgeable Technicians Available and On Call 24hrs a Day, 7 Days a Week 1 Sealweld Valve & Actuator Services o Valve Commissioning o Annual Maintenance & Inspection o Emergency Leak Sealing o Valve & Actuator Repair & Upgrades
3 Sealweld Valve & Actuator Training ValvePro Certification Class - UT Flex Valve & Actuator Training Flex Training is a customized course to fit attendees knowledge level and to specifically to cover common Valve & Actuator models/styles found on or at your location. 2
4 Sealant Guns & Pumps NEVER use low-pressure automotive-type grease guns when servicing a valve under pressure! 3
5 4 Hydraulic Hand Gun Pump Test internal relief valve at least once a year. Up to 10,000 psi injection pressure. 50 strokes = 1 oz. Gun capacity = 12 oz BEWARE: faulty internal relief valve possible. ALWAYS remove lubricant from its shipping packaging BEFORE loading pump! Reload with cartridge, stick or bag sealants. ALWAYS secure the handle.
6 5 Detecting Air in Fluid Bags Stroking handle - feels spongy or visible signs of handle movement after down stroke. Gun will NOT work in the upright position! Easily remedied.
7 Hydraulic Hand Pump 6
8 7 Alemite 6268 or Dualco o o o o Up to 15,000 psi maximum injection pressure. 25 strokes = 1 oz. Gun capacity = 12 oz. Turn the tail-crank to prime the pump. o Reload with cartridge, stick or bag sealants. o ALWAYS secure the handle. o Inability to build pressure may require head assembly replacement.
9 Sealweld SuperGun o o o o Reload with cartridge, o Up to 15,000 psi injection stick or bag sealants. pressure. ALWAYS secure handle. o 25 strokes = 1 oz. NOTE release valve on o Gun capacity 16 oz. hose assembly - use it! o Turn the tail-crank to prime the Easy to tell how much pump. sealant is left in the barrel. 8
10 9 Replaceable Piston Cartridge Sealweld SuperGun
11 10
12 Sealweld ACTIV-8 Pump Air/ hydraulic sealant pump psi air. Up to 10,000 psi injection pressure. Discharge 1 lb. of sealant in 2 minutes. Pumps from a 10 lb. pail, reload after 1 lb. Trip foot petal to OFF to reload. Each stroke on jack delivers 2oz. to barrel. Pedal has 3 positions: ON, OFF & PUSH. Run cleaner through pop valve to clean. 11
13 12 Rockwell Hypregun & Hypregun Plus Pneumatic 100:1 ratio sealant pump. Recommended 100psi inlet air pressure = 10,000 psi. Pumps from a 10 lb. pail. Use air or gas pressure. Original Hypregun: Discharge 1 lb./5 Min. Repairs to this type of unit can be costly! Updated Hypregun Plus: Discharge 1 lb./1 Min.
14 13 Hypregun Down-tube Assembly Air rams lower the pumping mechanism into the sealant pail. The sealant passes through a series of narrow passages. BEWARE of air pockets. ALWAYS bleed the air out of a new pail. Keep sealant clean, dirt and grit will damage seating surfaces in down-tube assembly.
15 14 High-Pressure Hose Assemblies ALWAYS use a high-pressure (HP) gauge on ALL guns. Use ONLY high-pressure (HP) fittings, swivels and hoses. Replace ALL broken or damaged components. BEWARE of vent hole in Release Valve! Hose length affects overall injection pressure. ALWAYS relieve pressure BEFORE removing coupler from the grease fitting!
16 The Mongoose Pump 15
17 Valve Inspection & Maintenance 16
18 Verify Valve Identification Utilize Companies most recent documentation: Valve Sheet, Company I.D., Name Plate, Valve Numbering Schematic. Verify Valve ID Number, Name Plate Tag, Valve Size, Valve Manufacturer & or valve type matches documentation. VALVE NUMBER SECURE AND LEGIBLE ON THE VALVE! If Valve ID Name Plate is missing, replace following company Specifications. Inspect External Valve Components for Corrosion & Damage Valve Body, Flanges, Mounting Bolts, Valve Bonnet, Any & ALL threaded connections including Lubricant Fittings, Body Bleed Fitting, Etc. Chipped Paint can lead to Atmospheric Corrosion! 17
19 Valve Operation- Prior to operating a valve, Personal MUST verify which valve is to be operated & Identify its location in the operators pipeline system. OPENING or CLOSING the WRONG valve could lead to unsafe conditions, Plant Shutdown, or Damage to equipment. Make note of the position of the Valve!! If applicable fully stroke or operate Valve! Always follow Company Spec. s which will determine how far a valve can be operated. If Applicable, contact Gas Control! Document A.O.C. Valve Security- Inspect & Verify all Locks, Chains, Gates are in good working Condition! Lubricate Locks with Lubricant Replace Damaged Locks 18
20 External Leaks- If Pipeline Carries Liquids, Spot the drip or run-off & Trace it to its origin on the Valve & DOCUMENT! (Stem Leak, Bonnet Leak, Etc.) If Pipeline Carries Gas, check for bubbling in the water, dead vegetation, hissing or whistling sound of escaping gas! DOCUMENT ALL EXTERNAL LEAKS!!! A.O.C. s Note: With Some Gaseous Materials, it may be necessary to use a mechanical Gas detector or Sniffer to verify External Leaks!
21 Valve Accessibility- ALL EMERGENCY or CRITICAL Valves MUST be READILY ACESSIBLE!! Make sure Valves in Units & Valve Boxes are not covered with Dirt or Debris! Documentation- Verify All A.O.C. s are PROPERLY and CLEARLY stated on Company Inspection Sheets. Stem, Bonnet, Flange Leaks & Fittings Valve UNOPERABLE ANY BROKEN OR MISSING COMPONENTS Corrosion LEAVE VALVE IN OPERATING POSITION THAT YOU FOUND IT IN!! 20
22 Preventative Maintenance is a program in which wear, damage, etc. are anticipated and continuous corrective actions are taken to ensure peak efficiency and minimize damage. PM involves a planned and controlled program of systematic inspection, adjustment, lubrication, and replacement of components! The dictionary defines Maintenance as follows : The work of keeping something in proper condition: UPKEEP 21
23 Topping Up Routine maintenance often consists of topping-up the lubricant/ sealant level in a valve s sealant system. The sealant system is a network of grooves and channels inside the valve leading to seal points around the ball, gate or plug. Typically ¼ oz. per inch in valve diameter, per seat is a good formula for topping up a valve. For Example: A 8 Ball Valve require 2 ounces of products on the upstream and downstream seat. 22
24 #1 Question Asked- Q: Why top off if the Ball Valve MANUFACTURER specifies NOT TO unless Valve is Leaking!? A: To verify Sealant passages, Riser Pipes, Fittings, etc. are free flowing. (HP Gauge will Indicate Flow) Example : If a valves normal operating position is open, and Years from now, during a project the Valve is finally closed and does not seal we know that secondary sealant grease channel passages are flowing from previous history of topping off. 23
25 Valve Operation is an important part of Valve maintenance. It will not only verify that the valve is functioning (Opening & Closing) but will also help crush, breakup, or dislodge any buildup on the Ball or Seat Face mating surfaces. 24
26 In colder Climates, winterize gear boxes by draining water from gear housing. If Valve is operated by a Gearing mechanism, Worm Gears, Bearings, Brass Sleeves should be greased/lubricated to minimize corrosion, binding & Wear. Use a good all purpose or Lithium based Bearing grease. Available in both Low Temp & High Temp. 25
27 A good practice is to spray a solvent/penetrant (PB Blaster) around the stem area annually. Rock or partially operate valves several times to break rust, paint, or partial debris from valve stem area. 26
28 When applicable, use body drain fittings to clear body cavities of trash & Liquids. Accumulated trash and debris over time can cause damage to a valves closure member and seat rings. 27
29 Always wear proper PPE! Safety First Using a backup wrench, verify bleed fitting is functioning & tightly installed! Identify the location of the exhaust port or Drain Hole Keep yourself & other personnel out of the line of fire. Open Body Bleed Fitting & drain any liquid, trash accumulation, line scale, etc. from Ball Valve Cavity. 28
30 ALWAYS Consult Valve Manufacturer/ Representative for help.
DO NOT USE LOW-PRESSURE GREASE GUNS FOR INJECTING SEAT SEALANT.
Chapter 3 Power Pumping Equipment Our field experience since 1969, has taught us that if you want the job done properly, you have to provide reliable and effective lubricant / sealant pumping equipment.
More informationOPERATOR S MANUAL Model 60010
OPERATOR S MANUAL Model 60010 10- TON SNAP LOCK PORTA POWER SET W/ WHEELED CASE PROFESSIONAL HYDRAULIC JACKS 1531 W. Mohawk Drive Phone 715-453-9602 Customer Service 800-995-2250 Tomahawk, WI 54487 Fax
More informationDoc. No Rev 0 Sealweld SuperGun
Owner's Manual - Original Instructions Doc. No. 100005 Rev 0 Sealweld SuperGun By Sealweld Corporation Owner s Manual - Sealweld SuperGun Content Page i This document is for the purpose of the Sealweld
More informationVELAN TRUNNION-MOUNTED
VELAN TRUNNION-MOUNTED Velan s standard trunnion-mounted ball valves offer increased value by incorporating advanced design features. TRUNNION-MOUNTED BALL The ball is fixed and the seat rings are floating,
More informationSEALANT INJECTION EQUIPMENT SEALANT INJECTION EQUIPMENT
SEALANT INJECTION EQUIPMENT SEALANT INJECTION EQUIPMENT Sealweld High-Pressure Sealant Injection Pumps Sealweld Sealant Injection Pumps are specifically designed to safely inject viscous sealants into
More informationTHREE PIECE TRUNNION MOUNTED BALL VALVE
Page: 1 of 13 INSTALLATION, OPERATION & MAINTENANCE MANUAL KF SERIES P3/M3 THREE PIECE TRUNNION Page: 2 of 13 CONTENTS BILL OF MATERIALS --------------------------------------------------------------------------------------------------------------------------------------------------
More informationHow innovation can avoid a shutdown
Keywords: Oil & Gas Valve seat Control valve Design V a lv e T e c h n o l o g y How innovation can avoid a shutdown This article describes how a novel solution was successfully implemented and allowed
More informationPRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY
PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been
More informationInstallation, Operation and Maintenance Manual
Installation, Operation and Maintenance Manual for the MOGAS ISOLATOR 2.0 Floating Ball Valve 1, 1.5, 2, 3 and 4 inch PREPARE THE VALVE FOR INSTALLATION INSTALL THE VALVE PROPERLY MAINTAIN THE VALVE FOR
More informationMERIDIAN, 2 or 3 PIECE, TRUNNION MOUNTED BALL VALVES
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS MERIDIAN, 2 or 3 PIECE, TRUNNION MOUNTED BALL VALVES Size Range 2 48 ASME Classes 150-2500 *It is recommended that the valve installer is familiar with
More informationMETERING VALVE 2" STEM GUIDED
2" STEM GUIDED All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to be construed
More informationRAM Company USA Products Line
RAM Company USA Products Line Trunnion Mounted Ball Valves Metal Seated Ball Valve 3-Way Ball Valve Jacket Ball Valve Ball Valves with Actuator Trunnion Mounted Ball Valves Main Features DOUBLE PISTON
More informationWKM. DynaSeal 370D4 Ball Valve. Installation, Operation and Maintenance Manual TC9276
WKM DynaSeal 370D4 Ball Valve Installation, Operation and Maintenance Manual All the information contained in this manual is the exclusive property of Cameron. Any reproduction or use of the calculations,
More informationBray/ VAAS Slurry Series Knife Gate Valve 760/762/765/766/767/768 Series Operation and Maintenance Manual
Bray/ VAAS Knife Gate Valve 760/762/765/766/767/768 Series Table of Contents Definition of Terms 1 Safety Instructions 1 Introduction 2 Unpacking 2 Storage 2 Installation 3 Commissioning 3 Cylinder-Operated
More informationIMO-200EN 09/2010. Trunnion mounted forged ball valves Model FF and GG. Installation, Maintenance and Operating Instructions IMO-200EN 09/2010
IMO-200EN 09/2010 Trunnion mounted forged ball valves Model FF and GG Installation, Maintenance and Operating Instructions IMO-200EN 09/2010 2 IMO-200EN Table of Contents I GENERAL INFORMATION...................
More informationONYX VALVE CO MODEL DAO-PFC Installation & Maintenance
ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance OPERATION: (4-2010) The Onyx DAO-PFC pinch valve is an open frame valve without housing enclosure and fails closed on loss of air. The actuator drives
More informationHIGH PRESSURE CONTROL VALVE PISTON BALANCED
PISTON BALANCED All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to be
More informationSlab & Double Expanding Gate Valves
Slab & Double Expanding Gate Valves Double Expanding Characteristics The main feature of a double expanding gate valve is the 2 pieces obturator that guarantees a simultaneous mechanical seal both in the
More informationLOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED
DIAPHRAGM BALANCED All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to
More informationPurging Air From Divider Block Lubrication Systems
FROST ENGINEERING SERVICE Purging Air From Lubrication Systems A D I V I S I O N O F G E C S E Y S A L E S & S E R V I C E DESCRIPTION Divider block lubrication systems operate correctly only when all
More informationONYX VALVE CO MODEL DAO-ADA Installation & Maintenance
ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance OPERATION: (4-2010) The Onyx DAO-ADA pinch valve is an open frame valve without housing enclosure and fails last position on loss of air. This actuator
More informationModel VR4 Vacuum Regulator
Model VR4 Vacuum Regulator Installation, Operation & Maintenance General: The Archer Instruments Model VR4 vacuum regulator is designed for use in vacuum gas feed systems. The VR4 incorporates an integral
More informationGREASE GUNS SECTION TWO. Battery Powered Grease Guns
Battery Powered Grease Guns and Accessories Professional Series Heavy Duty Series High Pressure Series Specialty Series Standard Duty Series Grease 1-866-4-ALEMITE Gun (866-425-3648) Accessories Alemite
More informationIBT Series Square Drive Torque Wrenches
IBT Series Square Drive Torque Wrenches Operation and Maintenance Manual Model.75, 1, 3, 5, 8, 10, 20, 25, 35, 50 http://www.torsionx.com Use the IBT Series Square Drive Torque Wrenches Model.75, 1, 3,
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS DISC BRAKE CONVERSION KIT A120-20, A120-21 1964 1 /2-66 Ford & Mercury Thank you for choosing STAINLESS STEEL BRAKES CORPORATION for your braking needs. Pleases take the time
More informationContents. Dimensions and weights
G4N Gate Valves Through-conduit, double block-and-bleed slab gate valves with fully protected seat faces for long-lasting, drop-tight shutoff in liquid pipelines Contents General information 3 Standard
More informationDP33 Pump. 60:1, 3+3, Air-operated, Grease. General. Operation. Technical Data. Installation R2 08/15
DP33 Pump 0:1, 3+3, Air-operated, Grease General The DP33 Pump is a compressed air-operated reciprocating piston pump designed to pump all types of mineral greases. Suitable for installations with medium
More informationOperating instructions Form no safety definitions
Operating instructions Form no. 1000437 safety definitions safety symbols are used to identify any action or lack of action that can cause personal injury. Your reading and understanding of these safety
More informationservicing the swivel
servicing the swivel The swivel seals and bearings require periodic replacement. This document describes how to determine which service procedure to use to service the swivel assembly, part number 101110.
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS DISC BRAKE CONVERSION KITS A121-1, A121-2, A121-3, A121-4 1967-69 Ford & Mercury Thank you for choosing STAINLESS STEEL BRAKES CORPORATION for your braking needs. Pleases take
More informationOperation and Maintenance Manual http://www.torsionx.eu Use the MaxDrv Series Square Drive Torque Wrench Model.75, 1, 3, 5, 8, 10, 20, 25, 35, 50 to install and remove threaded fasteners requiring precise
More informationUnder Axle Jack Max. Capacity: 25 Tons
SPX Corporation 655 Eisenhower Drive Owatonna, MN 55060-0995 USA Phone: (507) 455-7000 Tech. Serv.: (800) 533-6127 Fax: (800) 955-8329 Order Entry: (800) 533-6127 Fax: (800) 283-8665 International Sales:
More informationValveworks USA Operation and Maintenance Booklet Model FC
Operation and Maintenance Booklet Model FC MODEL FC 3000, 5000, 10000, & 15000 W.P. FLOATING SLAB GATE VALVES 1 13/16-2 1/16-2 9/16-3 1/16-4 1/16 BOOKLET APPROVED BY: INTRODUCTION In appreciation to you
More informationHIGH PRESSURE CONTROL VALVE R2L ACTUATOR
R2L ACTUATOR All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to be construed
More informationONYX VALVE CO MODEL DAO-PFO Installation & Maintenance
ONYX VALVE CO MODEL DAO-PFO Installation & Maintenance OPERATION: (4-2010) The Onyx DAO-PFO pinch valve is an open frame valve without housing enclosure and fails open on loss of air. The actuator drives
More informationDELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING
DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : NOMINAL SIZE MATERIAL MAXIMUM SERVICE PRESSURE 200, 150, 100, 80 & 50NB Cast Iron 12 Bar (175 PSI) THREADED OPENING MOUNTING FACTORY HYDROSTATIC TEST PRESSURE
More informationPRODUCT OVERVIEW. Our BDB (Bolted Body) and BW3 (Fully Welded Body) trunnion-mounted ball valves are designed and manufactured
PRODUCT OVERVIEW For over 30 years, FluoroSeal has been manufacturing and customizing a wide range of valves, and accessories for many industries including Oil & Gas, Petrochemical, Chemical, Mining, Pharmaceutical,
More informationOPERATION & MAINTENANCE MANUAL API 6A SLAB GATE VALVE AAS-013 REV C
OPERATION & MAINTENANCE MANUAL API 6A SLAB GATE VALVE AAS-013 REV C TABLE OF CONTENTS I. Introduction............................................. 3 II. Installation and Operating Instructions..............................
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS PERFORMANCE AT THE WHEELS KIT W120-22, W120-23 1964 1/2-69 MUSTANG Thank you for choosing STAINLESS STEEL BRAKES CORPORATION for your braking needs. Pleases take the time to read
More informationAir-Assist Service Jack Max. Capacity: 10 Tons
Form No. 565786 Parts List & Operating Instructions for: 1511B Air-Assist Service Jack Max. Capacity: 10 Tons 109 67 66 68 77 69 70 78 95 94 107 106 108 26 71 72 72 93 X L 65 75 92 91 90 89 88 87 86 85
More informationService Handbook. High-Pressure Washer Pump
Pump 629 9/28/01 3:22 PM Page 1 Service Handbook High-Pressure Washer Pump 3.532-629.0 10.00 Pump 629 9/28/01 3:22 PM Page 2 Pump 629 9/28/01 3:22 PM Page 3 TROUBLESHOOTING OVERVIEW How to Use This Manual
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS FRONT DISC BRAKE CONVERSION KITS A148-9 & A148-15 1949-54 Chevy Trucks Thank you for choosing STAINLESS STEEL BRAKES CORPORATION for your braking needs. Please take the time to
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL AOP SERIES D TRUNNION BALL VALVE, 2 FP 6 RP
INSTALLATION, OPERATION AND MAINTENANCE MANUAL AOP SERIES D TRUNNION BALL VALVE, 2 FP 6 RP CONTENTS 1. Parts list... 2 2. Description.. 10 3. Safety information s. 10 4. Installation and storing 10 5.
More informationSteam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions
INSTALLATION AND MAINTENANCE INSTRUCTIONS IM-8-002-US October 2016 Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions These instructions should be read by the Company
More information15,000kg HYDRAULIC BOTTLE JACK
Product Code: 2013 OWNER S MANUAL PRODUCT CODE: 2013 15,000kg HYDRAULIC BOTTLE JACK Lifting Capacity 15,000kg Max. Lifting Height 447mm Min. Lifting Height 227mm Hydraulic Lift 125mm Screw Adjustment 70mm
More informationInstallation Instructions
Installation Instructions Rear Disc Brake Conversion Kit Item # RC1001, RC1001X Applications: 64-72 A-body, 67 F-Body, 63-67 X-body with Non Staggered Shocks Thank you for choosing GPS Auto for your automotive
More informationHigh Lift Transmission Jack
655 Eisenhower Drive Owatonna, MN 55060 USA Phone: (507) 455-7000 Tech. Serv.: (800) 533-6127 Fax: (800) 955-8329 Order Entry: (800) 533-6127 Fax: (800) 283-8665 International Sales: (507) 455-7223 Fax:
More informationInstallation Instructions
Installation Instructions Rear Disc Brake Conversion Kit Item # RC4001, RC4001X Applications: Mopar 7.25, 8.25, 9.25 Axles Thank you for choosing Leed Brakes for your automotive product needs. Before you
More informationAIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS
I. OPERATION & DESCRIPTION The Air / Hydraulic Injection Gun is a high-pressure tool that should be used with caution and according to these instructions. IMPORTANT: The Gun is 0,000 psi rated. Do not
More informationModel Ton Hand Carry Axle Jack P/N: CJ67D0250-1
Model 1504-50 15 Ton Hand Carry Axle Jack P/N: CJ67D0250-1 Operation and Maintenance Manual with Illustrated Parts List 2222 South Third Street Columbus, Ohio 43207-2402 Phone (614) 443-7492 FAX (614)
More informationFisher 657 Diaphragm Actuator Sizes and 87
Instruction Manual 657 Actuator (30-70 and 87) Fisher 657 Diaphragm Actuator Sizes 30 70 and 87 Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 2 Installation... 3 Mounting
More informationHexPro Series Low Profile Wrenches
HexPro Series Low Profile Wrenches Operation and Maintenance Manual Model 2HP 4HP 8HP 14HP 30HP www.torquetoolsinc.com Use the HEXPRO Series Low Profile Wrenches Model 2HP 4HP 8HP 14HP 30HP to install
More informationOWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5
MODELS 282050, 282716 & 283513 AIR OPERATED CHASSIS PUMP SERIES A OWNER/OPERATOR MANUAL SPECIFICATIONS Airmotor effective dia. in. 2.5 Airinlet Material outlet 1/4 NPTF 1/4 NPTF Liquid to Air Pressure
More informationOperation and Maintenance Manual Model.75,, 3, 5, 8, 0, 0, 5, 35, 50 http://www.torsionx.com Use the MaxDrv Series Square Drive Torque Wrench Model.75,, 3, 5, 8, 0, 0, 5, 35, 50 to install and remove threaded
More informationMAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P
MANUAL NUMBER P-EFS-1 MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P TRAC Regulator Company Inc. 160 South Terrace Avenue Mount Vernon, New York USA 10550-2408 Phone: (914)
More informationTRUNNION MOUNTED BALL VALVE INSTALLATION, MAINTENANCE, & REPAIR MANUAL
TRUNNION MOUNTED BALL VALVE INSTALLATION, MAINTENANCE, & REPAIR MANUAL Corporation 3245 S. Hattie Oklahoma City, Oklahoma 73129 Telephone: (405) 677-3321 Fax: (405) 677-3917 Email:Balon@balon.com www.balon.com
More informationSECTION 1 LUBRICATION
SECTION 1 LUBRICATION Model M2500 OMPS1 M2500 10-2002 Avoid injury! Bring all crane functions to complete stop and turn off engine before lubricating crane. If necessary, spot grease fittings at access
More informationKimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc.
TREATER VALVE All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to be construed
More informationSD Bendix E-10PR Retarder Control Brake Valve DESCRIPTION. OPERATION - Refer to Figure 2
SD-03-832 Bendix E-10PR Retarder Control Brake Valve MOUNTING PLATE SUPPLY 4 PORTS ELECTRICAL AUXILIARY DESCRIPTION TREADLE RETARDER CONTROL SECTION EXHAUST DELIVERY 4 PORTS FIGURE 1 - E-10PR RETARDER
More informationOPERATION AND MAINTENANCE MANUAL
WREN IBT SERIES HYDRAULIC TORQUE WRENCHES IBT SQUARE DRIVE SERIES OPERATION AND MAINTENANCE MANUAL FOR WREN Products: POINT 75, 1IBT, 3IBT, 5IBT, 8IBT, 10IBT, 20IBT, 25IBT, 35IBT, 50IBT SQUARE DRIVE HYDRAULIC
More informationOperating & Maintenance Manual For Steam Conditioning Valve
For Steam Conditioning Valve 1 Table of Contents 1.0 Introduction 3 2.0 Product description 3 3.0 Safety Instruction 4 4.0 Installation and Commissioning 5 5.0 Valve Disassembly 6 6.0 Maintenance 6 7.0
More informationTable 6-1. Problems and solutions with pump operations. No Fluid Delivery
Table 6-1. and solutions with pump operations No Fluid Delivery Fluid level in the reservoir is low. Oil intake pipe or inlet filter is plugged. Air leak in the inlet line prevents priming or causes noise
More informationAIRGO MISTING SYSTEM MAINTENANCE
AIRGO MISTING SYSTEM MAINTENANCE WARNING: Disconnect the fan and misting pump from power before servicing. Service schedule Schedule Procedure 50 hours of operation Initial oil change 300 hours of operation,500
More informationHydro-Max Hydraulic Brake Booster and Master Cylinder. Technical Manual
Hydro-Max Hydraulic Brake Booster and Master Cylinder Technical Manual * 5+0 Important Service Notes The information in this publication was current at the time of printing. The information presented in
More informationAir Assist Bottle Jack Max. Capacity: 12 Tons (4313C) & 20 Tons (4321C) Operating Range: psi
Form No. 545742 Parts List and Operating Instructions for: 4313C 4321C Air Assist Bottle Jack Max. Capacity: 12 Tons (4313C) & 20 Tons (4321C) Operating Range: 40 150 psi 45 44 43 42 41 40 39 22 1 37 28
More informationSD Bendix E-12 & E-15 Dual Brake Valve DESCRIPTION
SD-03-6 Bendix E- & E-15 Dual Brake Valve TREADLE UPPER BODY ASSEMBLY PRIMARY DELIVERY ( ) 1 SECONDARY DELIVERY ( ) LOWER BODY ASSEMBLY MOUNTING PLATE PRIMARY SUPPLY ( SUP-1) PRIMARY SUPPLY ( SUP-) PRIMARY
More informationANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS
Before installation these instructions must be fully read and understood TABLE OF CONTENTS 1. General valve description and start-up... 1 2. Main valve maintenance... 1 3. Pilot maintenance... 5 4. Pilot
More informationVLW18TE, VLW18TI HYDRAULIC VERTICAL LIFTING WEDGES. Operator Instruction Manual INNOVATION IN ITS MOST FUNCTIONAL FORM
VLW18TE, VLW18TI HYDRAULIC VERTICAL LIFTING WEDGES Operator Instruction Manual info@equalizerinternational.com www.equalizerinternational.com INNOVATION IN ITS MOST FUNCTIONAL FORM INDEX SECTION CONTENTS
More informationTWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air
ORIGINAL INSTRUCTIONS Form No.1000458 5 SPX Corporation 5885 11th Street Rockford, IL 61109-3699 USA Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031 Internet
More information4 - Way Control 4 - Way Control 4 - Way Control with lock
INSTALLATION / OPERATION / MAINTENANCE 1. DESCRIPTION MODEL 0-02 (Full Internal Port) Powertrol Valve This manual contains information for installation, operation and maintenance of the Cla-Val Co. 0-02
More informationOPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP
PAGE 1 OF 10 OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP EFFICIENT, EASY OPERATION Air operated pump Wide range of pressures and volumes Easy to operate controls Output pressure
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS COMP. R AND COMP. S QUICK CHANGE KITS A200, A200-1 Thank you for choosing STAINLESS STEEL BRAKES CORPORATION for your braking needs. Pleases take the time to read and carefully
More informationService Jacks. Operating Instructions & Parts Manual. Model Number. Capacity 4 Ton 4 Ton Air/ Manual 10 Ton 10 Ton Air/ Manual HW93657/ HW93660
Service Jacks Operating Instructions & Parts Manual Model Number HW93657 HW93667 HW93660 HW93662 Capacity 4 Ton 4 Ton Air/ Manual 10 Ton 10 Ton Air/ Manual Made in North America HW93657/ HW93660 HW93667/
More informationDP3 Pump. 3:1, Air-operated, Oil. General. Operation. Technical Data. Installation R0 10/09. 35a 35b 35c
DP3 Pump 3:1, Air-operated, Oil General The DP3 Pump is a compressed air-operated piston reciprocating medium pressure pump. Suitable for medium flow transfer of high viscosity lubricants and for oil delivery
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS MODEL: GRAFTON RH-510 1 REV.A Restoration Hardware Balance Pressure Tub /Shower Set Specification Diagram Ensure that the stop ring () is correctly installed, prior to finished
More informationChapter 3 Lubrication
Chapter 3 Lubrication Avoid injury! Bring all crane functions to complete stop and turn engine OFF before lubricating crane. If necessary, spot grease fittings at access points, then stop engine. Attach
More informationLow Profile Wrenches Operation and Maintenance Manual
Low Profile Wrenches Operation and Maintenance Manual http://www.torquetoolsinc.com Use the HEXPRO Series Low Profile Wrenches Model 2HP 4HP 8HP 14HP 30HP to install and remove large bolts that have minimal
More informationDP5 Pump. 5:1, Air-operated, Heavy Duty, Oil. General. Operation. Technical Data. Installation R1 09/10
DP5 Pump 5:1, Air-operated, Heavy Duty, Oil General The DP5 Pump is a compressed air-operated reciprocating piston medium pressure pump. These pumps are suitable for distribution of all types of light
More informationTHIS WARRANTY IS IN LIEU
Installation, Operation, Maintenance and Parts Manual for Backflow Prevention Assemblies Double Check Valve Assembly Series 2000DCA 4" 10" Double Check Detector Assembly Series 3000DCDC 4" 10" Reduced
More informationONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance
ONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance OPERATION: (4-2010) The Onyx series CAR-PFO and CAP-PFO pinch valves fail open on loss of air. The simple spring and air bag arrangement drives
More informationBUREAU OF STANDARDS. Effective Date: 8/19/2016 Section No. 4. Version: 1.2 Procedure No. 3
BUREAU OF STANDARDS Effective Date: 8/19/2016 Section No. 4 Version: 1.2 Procedure No. 3 TITLE: LP Gas Bulk Plant Final Inspection PURPOSE: This document details the procedures used to conduct a Final
More informationHYDRAULIC PUMP. INSTALLATION, OPERATION, & MAINTENANCE MANUAL MAINTENANCE MANUAL #: MM-HP Rev. A Page 1 of 12
INSTALLATION, OPERATION, & #: MM-HP001 4-20-09 Rev. A Page 1 of 12 HYDRAULIC PUMP PART NUMBER HP46982ALSL & HP46982SL HYDRAULIC PUMP MM-HP001 Rev. A Page 2 of 12 Table of Contents 1.0 General Page 3 2.0
More informationDP556 Pump. 55:1, Air-operated, Grease. General. Operation. Technical Data. Installation. Mounting with Reinforced Cover (Recommended)
DP556 Pump 55:1, Air-operated, Grease General The DP556 Pump is a compressed air-operated reciprocating piston pump. This high capacity demand pump is compatible with mineral and synthetic grease and suitable
More informationOperation & Service Manual
Operation & Service Manual Model: 02-1248-0112 12 Ton Single Stage Jack 11/2004 Rev. 02 Includes Illustrated Parts Lists 1740 Eber Rd Tronair, Inc. Phone: (419) 866-6301 Holland, OH 43528-9794 www.tronair.com
More informationTECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)
1 of 9 1. DESCRIPTION The Viking 2 (DN50) is a quick-opening, differential diaphragm, flood valve with one moving part. The deluge valve is used to control water flow in deluge and preaction sprinkler
More informationInstallation Instructions
Installation Instructions Rear Disc Brake Conversion Kit Item # RC2001, RC2001X Applications: Mopar 8-3/4 & 9-3/4 Rear Axles Thank you for choosing Leed Brakes for your automotive product needs. Before
More informationMaintenance Manual Reduced Pressure Assembly Models 860 & 880V 2 1 /2" 10"
IOM-F-860_880V INSTALLATION, OPERATION, MAINTENANCE Maintenance Manual Reduced Pressure Assembly Models 860 & 880V 2 1 /2" 10" 860 880V Standard Configuration 880V Vertical Configuration INDEX Vandalism..............................................
More informationCARTRIDGE FILTER SYSTEMS OWNER S MANUAL
CARTRIDGE FILTER SYSTEMS OWNER S MANUAL Installation Operation Parts Designed, Engineered & Manufactured in the USA. 2017 Waterway Plastics 2200 East Sturgis Road, Oxnard CA 93030 Phone 805.981.0262 Fax
More informationI & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1-1/2-2 )
I & M Mark 8 Series 0 Wasson Road Cincinnati, OH 4509 USA Phone 5-5-5600 Fax 5-8-005 info@richardsind.com www.jordanvalve.com Installation & Maintenance Instructions for Mark 8 Control Valves (-/ - ) Warning:
More informationVal-Matic QuadroSphere Trunnion Mounted Ball Valve
Manual No. QS-OM1-1 Val-Matic QuadroSphere Trunnion Mounted Ball Valve Operation, Maintenance and Installation Manual INTRODUCTION... 2 RECEIVING AND STORAGE... 2 INSTALLATION... 2 DESCRIPTION OF OPERATION...
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS FRONT DISC BRAKE CONVERSION KIT A129-2 1959-64 Full Size Chevrolet Car and FRONT DISC BRAKE CONVERSION KITS A129-3 & A129-4 1965-68 Full Size Chevrolet Car Thank you for choosing
More informationCollision Repair Set. Form No No. 1517A 4-Ton Set. No. 1519A 10-Ton Set. Parts List & Operating Instructions for: 1519A. Part No. Item No.
SPX Corporation 655 Eisenhower Drive Owatonna, MN 55060-0995 USA Phone: (507) 455-7000 Tech. Serv.: (800) 533-6127 Fax: (800) 955-8329 Order Entry: (800) 533-6127 Fax: (800) 283-8665 International Sales:
More informationModel: TON AXLE JACK. March 1999 Rev.-02
Model: 02-7832-0100 March 1999 Rev.-02 TABLE OF CONTENTS PAGE 1.0 DESCRIPTION1 2.0 USAGE... 1 3.0 SPECIFICATIONS... 1 4.0 ASSEMBLY INSTRUCTIONS... 1 4.1 General Information... 1 4.2 Pre-Use Checks... 1
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS COMP CALIPER QUICK CHANGE KIT A213 1968-73 MUSTANG Thank you for choosing STAINLESS STEEL BRAKES CORPORATION for your braking needs. Pleases take the time to read and carefully
More informationI & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1/2-1 )
I & M Mark 8 Series 30 Wasson Road Cincinnati, OH 4509 USA Phone 53-533-5600 Fax 53-8-005 info@richardsind.com www.jordanvalve.com Installation & Maintenance Instructions for Mark 8 Control Valves (/ -
More informationPressure Relief Valve Maintenance Manual
Technical Manual 1098T Pressure Relief Valve Maintenance Manual Farris Engineering Division of Curtiss-Wright Flow Control Corporation TABLE OF CONTENTS - Manual Revision 0 Introduction & Safety Tips...
More informationAir Assist Bottle Jack Max. Capacity: 12 Tons (4313C) & 20 Tons (4321C) Operating Range: psi
R SPX Division 655 Eisenhower Drive Owatonna MN 55060 Phone: (507) 455-7000 Tech. Serv.: (800) 533-6127 Fax: (800) 955-8329 Order Entry: (800) 533-6127 Fax: (800) 283-8665 International Sales: (507) 455-7223
More informationONYX VALVE CO MODEL DAC-PFO Installation & Maintenance
ONYX VALVE CO MODEL DAC-PFO Installation & Maintenance OPERATION: (01-10) The Onyx series DAC-PFO pinch valve fails open on loss of air. This simple spring and air bag arrangement that drives a pair of
More informationAir Actuated Hydraulic Bottle Jacks
Air Actuated Hydraulic Bottle Jacks Operating Instructions & Parts Manual Model Number Atd-7412 Atd-7420 Capacity 12 Ton 20 Ton Atd Tools Inc. 160 Enterprise Drive, Wentzville MO 63385 Printed in China
More informationInjector. General Information CAUTION. Use only the specified injector for the engine.
Page 1 of 32 006-026 Injector General Information CAUTION Use only the specified injector for the engine. All engines use closed nozzle, hole-type injectors. However, the injectors can have different part
More information