Units per package KPRO2-E250 KPRO2-E69 PRO1MICRO HYGIENE INDICATORS CHEMDYE. 50 vials + 50 SW250 swabs
|
|
- Garey Owens
- 6 years ago
- Views:
Transcription
1
2 HYGIENE INDICATORS CHEMDYE KPRO2-E250 Hygiene Monitoring System. Kit system for detecting residual protein on endoscopes and other cannulated instruments. With flexible 2.5 m SW250 swab. Vials with 0.44 ml colorimetric reagent. Instant reaction. Turns from Amber to Blue. Includes swab moisturizer per box. 50 vials + 50 SW250 swabs KPRO2-E69 Hygiene Monitoring System. Kit system for detecting residual protein on surfaces. With 6.9 cm SW69 swab. Vials with 0.44 ml colorimetric reagent. Instant reaction. Turns from Amber to Blue. Includes swab moisturizer per box. 50 vials + 50 SW69 swabs PROMICRO High sensitivity pen system for the detection and quantification of surface proteins and allergens. High absorption swab which allows the collection of samples on different types of surfaces. Detection limit: μg. Sensitivity: 0.5 μg. ISO / HTM 0-0 / HTM
3 WASH INDICATORS CHEMDYE CCDER Reprocessors. Challenge Device + luer-lock CCDER22 Reprocessors. Challenge Device + 3 luer-lock CCDER2 Reprocessors. Challenge Device + luer-lock CDWA3 Cleaning Indicator for cleaning performance tests. Challenge level: high. Allows detection of all factors affecting the outcome of cleaning process. Size: (70 x 30 mm). Initial Color: Blue Result: elimination of blue organic substance. ISO/TS CDWA4 Cleaning Indicator for cleaning performance tests. Challenge level: very high. Allows detection of all factors affecting the outcome of cleaning process. Size: (70 x 30 mm). Initial Color: Fuchsia. Result: elimination of fuchsia organic substance. ISO/TS CDWAH Holder for CDWA cleaning Indicator, stainless steel re-usable holder of great resistance and durability. Base: 32 mm wide, 72 mm long, pin at the back side. Basket: 32 mm wide, 37 long, 7 mm thick. ISO/TS CDWE Cleaning Indicator for endoscope cleaning performance tests in Automatic Endoscope Reprocessors. 20 2
4 WASH INDICATORS CHEMDYE KCCDER Reprocessors Kit. 20 indicator strips + luer-lock KCCDER22 Reprocessors Kit. Challenge Device + 20 indicator strips + 3 luer-lock KCCDER2 Reprocessors Kit. Challenge device ( 2 m x 2 mm internal diameter ) + 20 indicator strips + luer-lock KCCDER2/ Reprocessors Kit. Challenge device ( m x 2 mm internal diameter ) + 20 indicator strips + luer-lock 3
5 WASH INDICATORS CHEMINK IKW4 Indicator ink for washing efficiency tests in washer-disinfectors. 2 4
6 WASH INDICATORS INTEGRON IT27W- One-side-laminated strip (70 x 30 mm) printed with indicator ink for routine control of thermal disinfection processes, min. 90 C, A0= 600 Turns from Green to Purple IT27W-0 One-side-laminated strip (70 x 30 mm) printed with indicator ink for routine control of thermal disinfection processes, 0 min. 93 C (BGA/RKI/EPIDEMIC PROGRAM) or equivalent. Turns from Green to Purple. IT27W-5 One-side-laminated strip (70 x 30 mm) printed with indicator ink for routine control of thermal disinfection processes, 5 min. 90 C, A0= 3000 Turns from Green to Purple. IT400 Package of non-absorptive material (25 mm x 70 mm). Polypropylene strip (0 mm x 45 mm) printed with indicator ink for monitoring of High Level Disinfection processes using Liquid Peracetic Acid. Turns from Violet to Fuchsia. 00 IT40 Package of non-absorptive material (25 mm x 70 mm). Polypropylene strip (0 mm x 45 mm) printed with indicator ink for monitoring of High Level Disinfection processes using Liquid Peracetic Acid. Turns from Brown to Blue or Greenish. 00 5
7 All products are made in its entirety in Argentina. Bionova, Chemdye, Chemink, Integron, Cintape and Humidigene are a registered trademark of Terragene S.A.
Cold Vapor Mercury Apparatus* Purpose Figure 1 Cold Vapor Mercury Apparatus Assembly Overview
26744-88 Cold Vapor Mercury Apparatus* Purpose This instruction sheet shows how to assemble the apparatus set (26744-00) necessary for performing the Hach Cold Vapor Mercury Method (method 10065). Figure
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025: and the Directive 93/42/EEC 2 and 90/385/EEC 3
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-18398-02-02 according to DIN EN ISO/IEC 17025:2005 1 and the Directive 93/42/EEC 2 and 90/385/EEC 3 Period of validity: 26.02.2018
More informationYesterday, today and tomorrow
Yesterday, today and tomorrow Why Scientific has consistently been the leading producer of transfer pipets for over 35 years. Design Grips easily with latex gloves no slipping Clear graduated markings
More informationVari-Disk Service. Inline disc filters to meet your needs. Inlet and outlet connectors. Filter housing
Inline Disc Filters Customised inline disc filtration for a wide range of applications Free bespoke sample production Wide variety of media and connector options Low production volumes at competitive prices
More informationReplacement Parts & Accessories for ASE Systems
Restek Sample Handling Replacement Parts & Accessories for ASE Systems Including Models 100, 150, 200, 300, and 350 www.restek.com Accelerated Solvent Extraction (ASE) Accelerated solvent extraction is
More informationCorning Sample Cooling and Heating Systems. A family of solutions that enables consistent, reproducible, and standardized sample handling
Sample Cooling and Heating Systems A family of solutions that enables consistent, reproducible, and standardized sample handling Ensure temperature consistency and minimize contamination risk It s well
More informationPhysiological Calibration Standard II Calibration standard physiological fluid CALIBRATION STANDARD PROTEIN
80-6000-32 Physiological Calibration Standard II 80-2037-62 Calibration standard physiological fluid 80-2037-61 CALIBRATION STANDARD PROTEIN HYDROLYSATE 80-2104-53 1/8" FLANGELESS FITTING (PK 5) 80-2108-41
More informationSINGLE WIRE SEALS AND CAVITY PLUGS
SINGLE WIRE SEALS AND CAVITY PLUGS for the Automotive Industry TE AUTOMOTIVE /// SINGLE WIRE SEALS AND CAVITY PLUGS for the Automotive Industry Seal to contact interface The contact barrels close and retain
More informationPerformance. Value. Peace of mind.
WYPALL* X Wipers promise a wide variety of superior cleaning solutions you can rely on to meet the highest performance standards and enhance productivity. Performance. Value. Peace of mind. All WYPALL*
More informationISO-9001:2008 DISPENSERS CATALOG. Phone: Fax: Web:
ISO-9001:2008 DISPENSERS CATALOG Phone: 281 496 0900 Fax: 281 496 0400 Email: sales@expotechusa.com Web: www.expotechusa.com 32 KIMAX Tilting Dispensers Tilted head allows accurate measurements _ Volume
More informationWarter Fuels JSC Aviation Gasoline AVGAS 115/145 Edition II
1. Scope of TS 2. Usage scope of TS subject 3. Division and designation 4. Requirements and research 4.1. General properties 4.1.1. Antiknock additives 4.1.2. Dyeing additives 4.1.3. Antioxidant additives
More informationVegetable based lubricating & degreasing solvent with high solvent power
Vegetable based lubricating & degreasing solvent with high solvent power PRODUCT DESCRIPTION IMPACT is Vegetable based degreasing solvent with high solvent power, demonstrated by a Kauri Butanol index
More informationmeasuring vessel air inlet conductivity cell reaction vessel sample absorption solution (water) heating block (e.g. 120 C)
Rancimat Practice Principle of Rancimat method air inlet measuring vessel reaction vessel conductivity cell sample heating block (e.g. 120 C) absorption solution (water) Preparing a determination reaction
More informationINTERNAL TRANSPORT UFlex KD Transport Cart... Sterisystem Stericart... Tambour Transport and Storage Carts...
www.belintra.com/us INTERNAL TRANSPORT UFlex KD Transport Cart... Sterisystem Stericart... Tambour Transport and Storage Carts... 3 5 7 This lightweight but sturdy transport cart made of anodized aluminum
More informationASTM D Standard Specification for Biodiesel Fuel (B 100) Blend Stock for Distillate Fuels
ASTM D 6751 02 Standard Specification for Biodiesel Fuel (B 100) Blend Stock for Distillate Fuels Summary This module describes the key elements in ASTM Specifications and Standard Test Methods ASTM Specification
More informationDatasheet. Description. STAXS Reference G-0019-L
Datasheet STAXS Reference Description G-0019-L SHIELDskin Bright Latex 300, latex, natural, 30cm, L, 50 pcs/dispenser, 10 dispensers/box Productomschrijving The supplier is responsible for the information
More informationDon t get caught out by the Sharps Directive
Don t get caught out by the Sharps Directive Total Needle Free Solutions From Fannin Sentra Safety IV Cannula Self activating safety needle guard with plastic cap Plastic safety cap reduces blood splatter
More informationVelocity Scientific Solutions
Shell Vials for Waters WISP, 8x40mm, 8mm Plug Vials Designed to work in the Waters WISP 96 position autosampler. Available in clear or amber Type I borosilicate glass, or polypropylene for easy disposal.
More informationSluice room. with people in mind
Sluice room solutions with people in mind 2 Sluice Room Solutions PLANNING AN OPTIMISED SLUICE ROOM Nosocomial infections are becoming more widespread and virulent. The need for effective infection control
More informationAutoplex Specifications
Autoplex Specifications Autoplex G1 w/heating coil Stainless steel tip holds up to 150µl of liquid Probe tubing holds up to 3.18ml of liquid (length=88in, diameter=0.673mm/0.053in, 36.1µl/inch-high surface
More informationRacks, baskets and storage for tubes pipettes and flasks
Racks, baskets and storage for tubes pipettes and flasks TUBE RACKS Schematic diagram indicating external measurements A-B-C-D A D C B A: Total length. B: Total width. C: Total height including feet. D:
More informationRelated vacuum products
Vacuum component C O N T E N T S variation 420 Position locking valve () 422 Compact vacuum regulator () 426 Vacuum break unit () 436 Vacuum filter large volume union type (VSFB) 440 Compact vacuum filter
More informationXLR-8 60 Extended Rack Autosampler
XLR-8 60 Extended Rack Autosampler ACCESSORIES AND PARTS CATALOG Catalog part number 620131 Rev 4, June 2018 Accessories and Supplies Sample Probes Length: 10 inches (25.4 cm) Probe Material: FEP-covered
More informationAmersham Western blotting membranes
Amersham Western blotting membranes Selection guide gelifesciences.com Make the right membrane choice for success in Western blotting GE Healthcare's Life Sciences solutions offers a broad selection of
More informationUsing Plates and Vials with ACQUITY UPLC and ACQUITY UPLC H-Class Systems
Using Plates and Vials with ACQUITY UPLC and ACQUITY UPLC H-Class Systems Follow the guidelines in this document when using plates and vials with ACQUITY UPLC and ACQUITY UPLC H-Class systems. For assistance
More informationCAB 3 TM marking and isolating sleeves
CAB 3 TM marking and isolating sleeves CAB 3 TM marking and isolating sleeves 388 50 388 58 388 63 Characteristics Material PA 6.6 halogen-free Installation temperature : - 5 C to + 40 C Operating temperature
More informationCentrifuge Operator / Service Manual
3000 Centrifuge Centrifuge Operator / Service Manual cat.# 26230 & 26231 The Q-sep 3000 centrifuge complies with all requirements of UL standard 3101 20, Can/CSA C22.2 No. 1010.1, and Can/CSA C22.2 No.
More informationN) manual. Register your instrument! Eppendorf Research plus. Operating manual
earch ual plus N) manual Register your instrument! www.eppendorf.com/myeppendorf Operating manual Copyright 2018 Eppendorf AG, Germany. All rights reserved, including graphics and images. No part of this
More informationPRODUCT CATALOGUE 2017 MED-CON PTY LTD SOLUTIONS FOR BIO-SECURITY. Web:
Web: www.medcon.com.au Email: sales@medcon.com.au MED-CON PTY LTD SOLUTIONS FOR BIO-SECURITY Phone: 1800 001 435 Fax: 03 5829 9803 PRODUCT CATALOGUE 2017 www.stericlin.com stericlin Why stericlin? 4 Indicator
More informationN) manual. Register your instrument! Eppendorf Reference 2. Operating manual
erence ual 2 N) manual Register your instrument! www.eppendorf.com/myeppendorf Operating manual Copyright 2016 Eppendorf AG, Germany. All rights reserved, including graphics and images. No part of this
More informationRegister your instrument! Eppendorf Reference 2. Operating manual
Register your instrument! www.eppendorf.com/myeppendorf Operating manual Operating Eppendorf see on Fig. Tab. p. p. manual Reference 2 Copyright 2016 Eppendorf AG, Germany. All rights reserved, including
More informationSOLUTIONS FOR TRADE Lighting Products November 2017
www.crh.com.au SOLUTIONS FOR TRADE Lighting Products November 2017 www.crh.com.au SOLUTIONS FOR TRADE CONTENTS Lighting Products Page 3-6 Page 7-8 Page 9-10 Page 11-12 Page 13-15 Page 16 Page 17 Cool Room
More informationPOLYMED CATALOGUE 2013 POLYCARBONATE STOPCOCKS MANIFOLDS - CONNECTORS
CATALOGUE 2013 POLYCARBONATE STOPCOCKS MANIFOLDS - CONNECTORS General Information COMPLIANCE PRODUCT The Luer taper fittings are conform to standard ISO 594-1 for syringes, needles and other medical devices.
More informationCorning CoolBox and CoolRack Consumable Compatibility Guide
Corning CoolBox and CoolRack Consumable Compatibility Guide A family of solutions that enables consistent, reproducible, and standardized sample handling Corning CoolBox for Consistent and Reproducible
More informationMB3600-CH30 Laboratory FT-NIR analyzer for biodiesel applications Suitable for production optimization and product quality assessment
Measurement & Analytics Measurement made easy MB3600-CH30 Laboratory FT-NIR analyzer for biodiesel applications Suitable for production optimization and product quality assessment FT-NIR optimizing productivity
More informationWater Baths & Shaking Water Baths. Quality Technology for Routine Applications
Water Baths & Shaking Water Baths Quality Technology for Routine Applications 94 Water Baths and Shaking Water Baths The TW and SW Water Bath Series are microprocessor-controlled, durable, and long-lasting
More informationSekisui Virotech GmbH ELISA System Diagnostic Error Sources and Approaches
Sekisui Virotech GmbH ELISA System Diagnostic Error Sources and es The following questionnaire shall help to identify the error source and provide the approach as quickly as possible. It is not assay specific
More informationMITRAS MATERIALS GMBH
MITRAS MATERIALS GMBH Friedrich-Ochs-Str. 2 92637 Weiden/Opf. Tel.: 0961 / 89-810 / 89-812 Fax: 0961 / 89-672 Directory of services L a b o r a t o r y MITRAS MATERIALS GMBH Edition 02/18 Rev. 08 page
More informationTECHNICAL SPECIFICATIONS
ROMPOX 1107 ESD coating Solvent free, electrically volume conductive, pigmented, 2 component epoxy resin system with formulated amine hardener acc. to DIN 61340 Areas of application: ROMPOX 1107 ESD coating
More informationTITREX. One instrument for all your titration and dosing applications
TITREX One instrument for all your titration and dosing applications The digital burette TITREX is ideal for a fast and sensitive titration drop by drop. One instrument simulates all volumes up to 99.99
More informationQuantitative Analysis of Chemical Compositions from Various Sources of Crude Glycerine
CMU.J.Nat.Sci.Special Issue on Agricultural & Natural Resources (2012) Vol.11 (1) 157 Quantitative Analysis of Chemical Compositions from Various Sources of Crude Glycerine Adisorn Settapong * and Chaiyawan
More information% PH Value 2% slurry IS: ph Green Compression Strength Bentonite : Water :10: A.F.S Sand
(Traders Exporters importers & Mfrs. in Heavy Chemicals, Acids, Dyes, Solvents, Auxiliaries, Minerals) No.7, Thiruverkadu Main Road, Near Ambattur Industrial Estate, Ayapakkam, Chennai-600 077 Tamilnadu
More informationEverything you need to protect your samples. Thermo Scientific Nunc and Nalgene Cryoware Products
Everything you need to protect your samples Thermo Scientific and Cryoware Products Researchers worldwide protect more than two billion samples inside Thermo Scientific cold storage equipment. With proven
More informationbehr Labor-Technik behrotest Equipment for the Determination of Crude Fibre
behr Labor-Technik behrotest Equipment for the Determination of Crude Fibre EN Crude Fibre Crude fibre: Fat-free organic substances in feedingstuffs which are insoluble in acid and alkaline media. Crude
More informationSpectacle Frame Parts
Spectacle rame Parts 2 Overview: Nose Pads 14 Tips & Tricks: Nose Pad Arms 16 Nose Pad Arms 18 Nose Pad Cushions 20 Overview: Screws and Nuts 46 Washers and Sleeves 50 Hinges 54 Overview: Temples and Temple
More informationBiodiesel Production from Used Cooking Oil using Calcined Sodium Silicate Catalyst
Biodiesel Production from Used Cooking Oil using Calcined Sodium Silicate Catalyst M.O. Daramola, D. Nkazi, K. Mtshali School of Chemical and Metallurgical Engineering, Faculty of Engineering and the Built
More informationEPOND SA CP 389 CH Vevey Switzerland.
EPOND SA CP 389 CH - 1800 Vevey Switzerland http://www.e-pond.biz SC-2 & SC-4 Accessories Commonly used Nebulizers with SC-2/SC-4 and FAST PFA-ST Nebulizer, High Pressure (Detachable ES-2040-57 Capillary)
More informationIn-Line Methods List for Automated Ion Analyzers. Flow Injection Analysis
In-Line Methods List for Automated Ion Analyzers Flow Injection Analysis 19 January 2018 1 In-line Modules: Method Number Analyte Lamp/Tubing Heater/tubing 10-107-06-6-A Ammonia Not used 850cm Tefzel
More informationFUNCTIONAL BENEFITS. The Premium range combine all required functions - Acoustic, SD and Safe.T - together with matching colours
PREMIUM High quality homogeneous vinyl floorings suitable for a wide range of uses, from education and healthcare to offices and public buildings SENSORIAL BENEFITS 102 modern colour palette including
More informationAgilent 7693A Automated Liquid Sampler
Agilent 7693A Automated Liquid Sampler Specifications Overview The Agilent 7693A is a state-of-the-art sample handling and injection system that provides the highest levels of precision and reliability
More informationQuickdraw. Model 2400 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority
Quickdraw Model 2400 Series Clearing The Airway Is Our #1 Priority Operating Instructions & Maintenance Manual, INC. 11064 Randall Street Sun Valley, CA 91352 USA www.sscor.com Email: marketing@sscor.com
More informationVINYL ROLLS. Allover effects / Acczent Excellence 80
VINYL ROLLS Allover effects / Acczent Excellence 80 VINYL ROLLS Allover effects / Acczent Excellence 80 The reference to create rich allover textures for high traffic areas Class 34 Total thickness: 2
More informationTSHR 6000 series TN/TS/TX analyzer
TSHR series TN/TS/TX analyzer Versatile, Accurate and Reliable Trace Level Nitrogen, Sulfur, Chlorine Analysis Petrochemicals Refineries Analytical Services Research Analysis The TSHR series TN/TS/TX Analyzer
More informationMini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide.
Mini-OTE 400 INSTALLATION INSTRUCTION TC-1335-IP Rev C, March 2017 www.commscope.com Mini-OTE 400 Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide 2 Tools Required
More informationACCESSORIES AND PARTS CATALOG
ASX-280 AUTOSAMPLER ACCESSORIES AND PARTS CATALOG Catalog part number 620130 Rev 7, February 2018 Accessories and Supplies Sample Probes Length: 10 inches (25.4 cm) Probe Material: FEP-covered carbon fiber
More informationACCESSORIES AND PARTS CATALOG
ASX-560 AUTOSAMPLER ACCESSORIES AND PARTS CATALOG Catalog part number 620127 Rev 9, February 2018 Accessories and Supplies Sample Probes Length: 10 inches (25.4 cm) Probe Material: FEP-covered carbon fiber
More information10 Maintenance. Agilent Technologies. This chapter describes the maintenance of the module Infinity Binary Pump User Manual
1260 Infinity Binary Pump User Manual 10 Maintenance Introduction to Maintenance and Repair 148 Warnings and Cautions 149 Cleaning the Module 151 Overview of Maintenance and Simple Repairs 152 Maintenance
More informationS 1125 HPLC Pump System
Routine S 170 EXPERT HPLC HPLC System SYSTEMS 500 The Sykam ROUTINE HPLC System S 500 is intended for all routine analysis. The system configuration is highly variable and several upgrade options make
More informationTRACE ELEMENTS IN URINE. Event #3, 2012
TRACE ELEMENTS IN URINE Event #3, 202 November 30 th, 202 Event #3, 202 Urine Arsenic The source of the test materials is human urine obtained from donor volunteers with informed consent. Urine was collected
More informationSulphurous acid - environmental hazards due to the combustion of fossil fuels (Item No.: P )
Teacher's/Lecturer's Sheet Sulphurous acid - environmental hazards due to the combustion of fossil fuels (Item No.: P7158000) Curricular Relevance Area of Expertise: Chemie Education Level: Klasse 7-10
More informationMODEL 905V OPERATING INSTRUCTIONS
MODEL 905V OPERATING INSTRUCTIONS Quantek Instruments 183 Magill Drive Grafton, MA 01519 Tel: (508) 839-3940 Fax: (508) 819-3444 Email: sales@quantekinstruments.com GENERAL DESCRIPTION These instructions
More informationBIOSAFETY CABINETS. SURFACE WIDTH: 120cm - 48
BIOSAFETY CABINETS TECNIPLAST BIOSAFETY CABINETS, SPECIFICALLY DESIGNED FOR ANIMAL RESEARCH LABORATORIES, GUARANTEE THE UTMOST PROTECTION OF THE OPERATORS FROM THE INHALATION OF INFECTIOUS PARTICLES, DUST,
More informationSafety. Handy-Glide Closure Glovebag. New APPLICATIONS
Handy-Glide Closure Glovebag New APPLICATIONS Botany Emergency Isola on Field Sampling Forensics Mailrooms Police Departments Sensi ve Chemicals Schools many other possibili es Handy Glide Closure Convenient
More informationAgilent 7693A Automated Liquid Sampler
IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Agilent 7693A Automated Liquid Sampler
More informationTRACE ELEMENTS IN URINE
TRACE ELEMENTS IN URINE Proficiency Test Report Event #1, 014 March 4 th, 014 Event #1, 014 Urine Arsenic The source of the test materials is human urine obtained from donor volunteers with informed consent.
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025: and the Directive 93/42/EEC 2 and 90/385/EEC 3
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-13412-01-02 according to DIN EN ISO/IEC 17025:2005 1 and the Directive 93/42/EEC 2 and 90/385/EEC 3 Indefinite since: 10.12.2018
More information4025 Synthesis of 2-iodopropane from 2-propanol
4025 Synthesis of 2-iodopropane from 2-propanol OH I + 1/2 I 2 + 1/3 P x + 1/3 P(OH) 3 C 3 H 8 O (60.1) (253.8) (31.0) C 3 H 7 I (170.0) (82.0) Classification Reaction types and substance classes nucleophilic
More informationPLASTIC Filters. Durable high quality Plastic filters for wide range of filtration applications
irrigationglobal.com filtration for irrigation systems PLASTIC Filters flow rates filtration degrees diameters max. operating pressure up to 50 m 3 /h (220 US gpm) 3500 22 micron ¾ 3 10 bar (150 psi) Durable
More informationModel 2310 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority
VX-2 Model 2310 Series Clearing The Airway Is Our #1 Priority Operating Instructions & Maintenance Manual, INC. 11064 Randall Street Sun Valley, CA 91352 USA www.sscor.com Email: marketing@sscor.com techsupport@sscor.com
More informationPACKAGING DOWN TO A SCIENCE 2018 LABORATORY CONTAINER & SUPPLY CATALOG
PACKAGING DOWN TO A SCIENCE 2018 LABORATORY CONTAINER & SUPPLY CATALOG WE HAVE PACKAGING DOWN TO A SCIENCE WE HAVE PACKAGING DOWN TO A SCIENCE VALUE ADDED SERVICES QORPAK EXCLUSIVE PRODUCTS BOTTLES WITH
More informationPRODUCT CATALOGUE - SPILL KITS
PRODUCT CATALOGUE - SPILL KITS A PORTABLE/TRUCK SPILL KITS (Refills kits and single items replacements available for all kits) 45l UNIVERSAL SPILL KIT: OILS, DIESEL, FUEL & SOLVENTS 75l UNIVERSAL SPILL
More informationConnectors & Connectors with valves
Connectors & Connectors with valves Inside... Omnifit Cap instructions... Small Bore Connectors... 3 with valves... Large Bore Connectors... 5 with valves... 5 T Block Connector... 6 In-line Connectors...
More information4001 Transesterification of castor oil to ricinoleic acid methyl ester
4001 Transesterification of castor oil to ricinoleic acid methyl ester castor oil + MeH Na-methylate H Me CH 4 (32.0) C 19 H 36 3 (312.5) Classification Reaction types and substance classes reaction of
More informationHomogeneous vinyl safety floorings for all applications FUNCTIONAL BENEFITS
SAFE.T Homogeneous vinyl safety floorings for all applications SENSORIAL BENEFITS Matching designs with Tarkett iq Granit, Primo Premium and Eclipse Premium ranges Coordinated accessories for a perfect
More informationDräger CPS 5800 Gas-Tight Suit
Dräger CPS 5800 Gas-Tight Suit The Dräger CPS 5800 is a limited-use chemical protective suit for industrial applications and operations on board that involve a gaseous, liquid or solid hazardous substance.
More informationProduct Overview of GYROZEN Centrifuges
www.gyrozen.com Microcentrifuges Product Overview of GYROZEN Centrifuges Clinical Centrifuges Multi-Purpose High Speed Centrifuges Large Capacity, High Speed Centrifuges Scan the QR-code for Rotor Selection
More informationStandard Operating Procedure for Detecting MEA Triazine in a Crude Oil Matrix using LONESTAR TM
Standard Operating Procedure for Detecting MEA Triazine in a Crude Oil Matrix using LONESTAR TM Contact us Owlstone Nanotech Inc 2012 The Owlstone logo, OWLSTONE, LONESTAR, OVG-4 and OHG are trademarks
More informationFROTH-PAK INDEX. General. FROTH-PAK mini kit
FROTH-PAK INDEX GENERAL FROTH-PAK mini kit FROTH-PAK 180 FROTH-PAK 600 FROTH-PAK 1900 GUN HOSE ASSEMBLY [GHA] NOZZLES General FROTH-PAK is a portable two component polyurethane spray foam kit which enables
More informationComparator The system for colorimetric water analysis. Applications. Water Treatment (e.g. Drinking Water) Pool-Water.
Comparator 2000+ The system for colorimetric water analysis Applications Water Treatment (e.g. Drinking Water) Pool-Water Research Centres Universities Special Applications Laboratory and Field Testing
More informationUFlex Storage System. Anodized aluminum. Thermal plastic bumper. A wealth of possible combinations STORAGE
Belintra's UFlex modular storage system was designed to be functional, durable, stable and expandable. Our unique storage system is made out of a high-quality anodized aluminium. UFlex offers an ergonomic
More informationConsistent. Reliable. Innovative. Your most trusted partner for sterilization products and services.
Consistent. Reliable. Innovative. Your most trusted partner for sterilization products and services. Monitoring Products for Steam Sterilization Table of Contents Crosstex Industrial is a division of Crosstex
More informationBID TABULATION 1 of 5
BID TABULATION 1 of 5 Butler Animal Health Supply, LLC (L) Miller Veterinary Supply Company, Inc. MEASURE MEASURE SECTION A - LIQUIDS 1 Alcohol 70%. 32 oz 120 Bottle 32 oz $0.09/oz $2.97 $356.40 4 (32oz
More informationanalytical laboratory glass funnels
80 analytical glass Manufactured from borosilicate glass. with short and 60 cone angle. These are in accordance with DIN 5 and ISO 798 standards. glass 0.0.00 0.0.060 0.0.080 0.0.00 0.0.0 0.0.50 diamater
More informationTable 1. Air Sampling Results (ng/m 3 ) for Building D (100 and 200, Mako Shark) at MHS Malibu High School Malibu, California
Table 1. Air Results (ng/m 3 ) for Building D (100 and 200, Mako Shark) at MHS Placard ID (August Lights Off Lights On (December 28, Summer 2015 Summer 2016 Summer 2017 101A 101 (west) 101B 101 (east)
More informationISO 3679 INTERNATIONAL STANDARD. Determination of flash point Rapid equilibrium closed cup method
INTERNATIONAL STANDARD ISO 3679 Third edition 2004-04-01 Determination of flash point Rapid equilibrium closed cup method Détermination du point d'éclair Méthode rapide à l'équilibre en vase clos Reference
More informationEXACTA SAFETY CABINETS
EXACTA SAFETY CABINETS EFO SERIES FOR INFLAMMABLE LIQUIDS EBO AND LED SERIES FOR GAS CYLINDERS ECO SERIES FOR CHEMICALS COMBINED SERIES INFLAMMABLES+CHEMICALS POLYPROPYLENE SERIES FOR CHEMICALS SAFETY
More informationBiodiesel Fundamentals for High School Chemistry Classes. Laboratory 7: Using Differences in Solubility to Remove Contaminants from Biodiesel
Laboratory 7: Using Differences in Solubility to Remove Contaminants from Biodiesel Topics Covered Solubility Polarity Like dissolves like Partition Ratio Equipment Needed (per pair or group) One graduated
More informationN) manual. Register your instrument! Eppendorf Research plus. Operating manual
search ual plus N) manual Register your instrument! www.eppendorf.com/myeppendorf Operating manual Copyright 2013 Eppendorf AG, Hamburg. No part of this publication may be reproduced without the prior
More informationceramus HiClass in dispensing
ceramus HiClass in dispensing ceramus Uncompromising reliability Years of experience gained by Hirschmann in liquid handling are reflected in the perfection embodied in ceramus and absolute attention to
More informationČSN EN ISO ČSN ISO 4832
Testing laboratory working sites: 1 Praha 2 Brno Areál Slatina, Tuřanka 115, 627 00 Brno The laboratory is qualified to provide expert opinions and to interpret test results. The Laboratory is qualified
More information14 Chromatography Columns
14 Chromatography Columns LC Columns Selection Guide Omnifit Labware columns offer the maximum performance for low to mid pressure liquid chromatography or flow chemistry applications. Simple to assemble,
More informationJUMO tecline H2O2 JUMO tecline PAA Sensor for hydrogen peroxide and peracetic acid
JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
More informationThe new range of service stations for vehicle A/C systems. Alaska START Alaska START HFO Alaska BUS Alaska PREMIUM Alaska PREMIUM HFO
The new range of service stations for vehicle A/C systems Alaska START Alaska START HFO Alaska BUS Alaska PREMIUM Alaska PREMIUM HFO Service stations for vehicle A/C systems The new ALASKA range of stations
More informationVolatile Organic Compounds Probe Maintenance Application Note TSI-149
Indoor Air Quality Volatile Organic Compounds Probe Maintenance Application Note TSI-149 TSI s Model 984, 985, 986 and 987 probes use a Photoionization Detector (PID) sensor to measure Volatile Organic
More informationSTS Directory Accreditation number: STS 0228
International standard: ISO/IEC 17025:2005 Swiss standard: SN EN ISO/IEC 17025:2005 TESTEX AG Schweizer Textilprüfinstitut Gotthardstrasse 61 CH-8027 Zürich Head: Responsible for MS: Dr. Jean-Pierre Haug
More informationeconomics and performance Spark Holland introduces OPTIMAS The optimum balance of BETTER SAMPLE CARE
BETTER SAMPLE CARE Spark Holland introduces OPTIMAS The optimum balance of economics and performance Spark Holland introduces OPTIMAS The optimum balance of economics and performance OPTIMAS The optimum
More informationAlliance HPLC DEFINED BY DEPENDABILITY, TODAY AND IN THE FUTURE
Alliance HPLC DEFINED BY DEPENDABILITY, TODAY AND IN THE FUTURE AN HPLC THAT WORKS AS HARD AS YOU DO Confidence in your results comes with high performance, day-to-day reliability, and overall system robustness.
More informationUPGRADE EXISTING AUTOFOAM
Zero Alkaline Batteries AutoFoam is now powered by the LumeCel rechargeable energy system, eliminating the need for alkaline batteries. With the LumeCel rechargeable energy system, AutoFoam is completely
More informationELIMINATOR Hermetic bi-flow filter drier Types DMB and DCB
Data sheet ELIMINATOR Hermetic bi-flow filter drier s DMB and DCB Hermetic bi-flow filter driers, types DMB and DCB are for use in liquid lines on heat pumps. Hermetic bi-flow filter driers have built-in
More informationBeakers LIPSOL LABWARE DETERGENT. 46 Tel: +44 (0) Fax: +44 (0) Beakers, low form
Beakers, low form l Complies with SO 3819 and DN 12331 l Excellent thermal performance l High resistance to chemical attack l White graduations and marking spot Height O.D. Pack qty. Price 1000/03M 5 30
More information