Pump System Technology. Owner's Manual SERIES LP PUMP. For series: LP50, LP200, LP450, LP650. Series LP50

Size: px
Start display at page:

Download "Pump System Technology. Owner's Manual SERIES LP PUMP. For series: LP50, LP200, LP450, LP650. Series LP50"

Transcription

1 Pump System Technology Owner's Manual SERIES LP PUMP For series: LP50, LP200, LP450, LP650 Series LP50

2 Dear Fill-Rite Customer, Congratulations on your purchase of Fill-Rite s new Series LP pump. We at Fill-Rite have built our worldwide reputation by designing the finest and most reliable pumps available in today s market. Your new pump was designed with pride by some of the best and most experienced fluid control experts available. We use the most advanced technology possible to give you a pump with the superiority you deserve and the quality you ve come to expect from Fill-Rite products. Sincerely yours, GENERAL DESCRIPTION The Fill-Rite LP Lube Pump is a positive displacement, direct drive pump for lubrication fluids. The rugged design makes for a long life of trouble-free operation. SAFETY The motors used in Fill-Rite LP pumps are listed with: Underwriters Laboratories Inc., a nationally recognized independent organization for product testing to ensure public safety. MOTOR The Fill-Rite Team WARNING Canadian Standards Association, a Canadian organization for product testing to ensure public safety. Explosion Hazard Static charge could result in a fire or explosion. Do not use pump with low flash point fluids (100 F or less) or in Hazardous locations. WARNING Electrical Hazard Improper use or installation can cause serious bodily injury or death. Motor must be properly grounded. Electrical wiring must be done by a licensed electrician. SAFETY INSTRUCTIONS 1. To ensure safe and efficient operation, it is essential to read the entire manual before installing or operating this product. 2. This pump is not suited for use with fluids containing water. 3. The pump motor is equipped with thermal overload protection. If overheated, it will shut itself off without damage to the windings. Turn off the pump power if this occurs. As the motor cools, it may start without warning if power is on. 4. NOTE: Pump has a built-in check valve with pressure relief to prevent fluid thermal expansion from causing unsafe system pressures. DO NOT USE ADDITIONAL CHECK VALVES OR FOOT VALVES UNLESS THEY HAVE PROPER PRESSURE RELIEF VALVES (MAX. 30 PSI) BUILT INTO THEM. GENERAL TECHNICAL INFORMATION Inlet: 2" female NPT mounting on pump, 1" female NPT for suction pipe. 2" male threads on quick detach adapter with 1" female NPT for suction pipe. Outlet: ¾" NPT Built in check valve, bypass and pressure relief valves Motor: Thermal overload protection Permanent sealed ball bearing construction Series LP50 kit pumps are as 115 VAC or 12VDC 115/230 VAC on bulk and demand pumps Performance Maximum outlet pressure from psi ( bar) Maximum flow rate: up to 36 qpm (34 lpm) Maximum viscosity of fluid pumped: See page 7. Maximum fluid temperature: 150 F Minimum fluid temperature: See viscosity chart page 7. Minimum dry vacuum: 6 inches of mercury Fluid Compatibility The LP pump is compatible with the following fluids: Motor Oil, Gear Oil, Hydraulic Oil, Industrial Coolant, Antifreeze (not to exceed 50% water), ATF, Waste Oil. The LP pump is NOT compatible with the following fluids: Water, Acids, Brake Fluid, Windshield Washer Fluid If in doubt about compatibility of a specific fluid, contact supplier of fluid to check for any adverse reactions to the following wetted materials. Cast Iron Steel Stainless Steel Brass Flourocarbon Zinc Pltd. Stl. Aluminum 2

3 GENERAL INSTALLATION INSTRUCTIONS NOTE: Pump has a built-in check valve with pressure relief to prevent fluid thermal expansion from causing unsafe system pressures. DO NOT USE ADDITIONAL CHECK VALVES OR FOOT VALVES UNLESS THEY HAVE PROPER PRESSURE RELIEF VALVES (MAX. 30 PSI) BUILT INTO THEM. All tanks must be properly vented. Use oil resistant pipe sealant on all threaded joints. Drums must be properly secured to prevent tip over when full or empty. MOUNTING LP PUMP USING QUICK-DETACH BUNG ADAPTER Quick-Detach Bung Adapter 1" Suction Pipe Figure 1a Use sealant here Mounting the LP Pump using the Quick-Detach Adapter (See Figure 1a & 1b) 1. Screw length of suction pipe into the quick-detach adapter that extends 1" to 2" above bottom of tank. 2. Screw quick-detach adapter securely into tank bung. 3. Lubricate O-ring on pump inlet. 4. Position pump on adapter. Pump can be rotated in 90 increments. Tighten 2 screws to secure pump to adapter. Figure 1b Tighten screws Lubricate O-ring Mounting the LP Pump using the Motor Bracket (See Figure 2 & 3) CAUTION MOTOR MOUNTING BRACKET Mounting Bracket Always mount pump using motor bracket when mounting pump to a vehicle. 1. Using mounting plate as template, mark holes on mounting surface. 2. Use four 3/8" bolts with lock washers and nuts to attach bracket to mounting surface. Tighten securely. Mounting the LP Pump directly to a tank (See Figure 4) The Pump inlet flange has a 2" female NPT thread that can be mounted directly to a 2" male pipe thread on the tank. If only female threads are available on the tank, use a 2" schedule 40 pipe nipple to connect pump to the tank. 1. Screw correct length of 1" suction pipe into the pump inlet flange 1" port. Suction pipe should extend 2" to 3" above bottom of tank. 2. Thread pump directly onto the 2" tank nipple and tighten securely. Mounting Bracket Horizontal Mounted Wall Mounted Figure 2 Figure 3 DIRECT MOUNTING INSTALLATION Use sealant here 1" Suction Pipe 2" Schedule 40 nipple 2" Tank Bung Figure 4 3

4 INSTALLATION, DISCHARGE PLUMBING ON PUMP OUTLET LP50 Kit Pumps (50psi): Install hose and nozzle using oil resistant pipe sealant on threads. Tighten securely. If desired, install nozzle boot as shown. Tighten bolts securely. 1 2 # 1 Description Screw, on motor LP200 Series Bulk Pumps (200psi): Use hoses, pipes, fittings, and meters that can safely handle the rated pump pressure. A short length of flexible hose (5 FT. min.) is required at the pump outlet before connecting to rigid metal piping. For best performance, use the largest inside diameter pipe practical for long runs of pipe to minimize pressure drop and maximize flow rate. LP450 and LP650 On Demand Pumps ( psi): Use hoses, pipes, fittings, and meters that can safely handle the rated pump pressure. WARNING High Pressure Fluid Hazard Improper installation can cause serious injury or death. Use hose and pipe fitings rated for a min. of 800 psi A short length of flexible hose (5 FT. min.) is required at the pump outlet before connecting to rigid metal piping. For best performance, use the largest inside diameter pipe practical for long runs of pipe to minimize pressure drop and maximize flow rate. 2 Plastic Washer, found in literature bag Instructions for Removing the Motor Bracket Note: Bracket screws with supplied plastic washers must be re-installed in the motor to prevent dirt and moisture from damaging motor. 1) Remove motor bracket screws and bracket. 2) Slip plastic washer over motor bracket and re-install into motor. Tighten to 30 in*lbs. DO NOT OVERTIGHTEN SCREWS. ELECTRICAL INSTALLATION WARNING Electrical Hazard Improper use or installation can cause serious bodily injury or death. Shut off all power before connecting wires to motor Electrical wiring must be done by a licensed electrician. LP50 Series Kit Pumps, AC Power Factory wired for 115VAC. Power to the unit should be supplied from a dedicated circuit breaker. AC extension cords must be capable of safely carrying the rated motor current. Use heavy duty, 3-wire, grounded extension cords. Note that long extension cords must be larger gauge wire to safely handle the electrical load: -up to 25 feet, 14 AWG wire -up to 50 feet, 12 AWG wire -up to 100 feet, 10 AWG wire NOTE: Many building codes require Ground Fault Circuit Interrupt (GFCI) protection. 4 LP50 Series Kit Pumps, 12V DC Power Factory wired for 12VDC. Circuit must be protected with a 50 amp automotive fuse. Power cord must be capable of safely carrying the rated current. Long power cords must be larger gauge wire to safely handle the electrical load. -up to 8 feet, 8 AWG wire -up to 20 feet, 4 AWG wire

5 LP200 Series Bulk Pumps See page 11 for factory set voltage. A diagram on the motor label describes how the electrical connections are to be made. Power to the motor should be supplied from a dedicated circuit breaker sized to handle the motor load. Provisions must be made to break both legs of the 230VAC circuit. Conduit should be used to protect all permanent wiring installations. LP450 & LP650 Series On-Demand Pumps WARNING Spill hazard Entire tank could be emptied by the On-Demand pump if a leak occurs in the nozzle, meter, hose, or piping. Turn power switch off when not attended. Pump Fluid Outlet "On-Demand" switch junction box. Customer supplied power here. Use sealed cable connection that prevents water from entering junction box. See page 12 for factory set voltage. Instructions in the "On-Demand" switch junction box describes the electrical connections. The neutral wire must be wired to the #3 terminal in the "On- Demand" switch juction box for proper operation. Ground wire must be connected to the green wire inside the "On-Demand" switch junction box. Power to the motor should be supplied from a dedicated circuit breaker sized to handle the motor load. Provisions must be made to break both legs of the 230 VAC circuit. Conduit should be used to protect all permanent wiring installations. OPERATING INSTRUCTIONS Note: Do not operate pump dry (except at initial startup), damage to pump could occur. LP200 Series Bulk Pumps: Place customer supplied nozzle in container to be filled. Turn on motor. Fill container to desired level. Shut off and remove nozzle. Turn off motor. LP450 and LP650 Pumps with "On Demand" switch: Make sure user supplied discharge nozzle is closed. Turn pump motor switch on. Motor may turn on momentarily to build pressure in line if pump has not been used recently. If motor does not shut off after 30 seconds, turn off power and see "Trouble Shooting Guide" on page 6. Place nozzle in container to be filled. Open nozzle. Motor will automatically turn on. Fill container or vehicle reservoir to desired level. Shut off nozzle. Pump motor will automatically shut off after 6 seconds. Turn off pump motor switch when not attended. Purge the air from the pump: Purge Valve and Purge Valve Screw are assembled to the pump at the factory. Purge Connector and plastic tube are in a plastic bag shipped with the pump. 1) Thread the Purge Connector to the Purge Valve. 2) Push the purge tube into the Purge Connector. 3) Start pump. Using a flathead screw driver, turn the Purge Valve Screw counter clockwise. When tube starts to fill with oil, tighten screw back down. Unit is now primed. 4) Remove Purge Tube by pushing in the black plastic portion of the Purge Connector and pulling the tube out. 5) Wipe up any oil drips. Purge Connector can be left on the pump or removed. LP450H0035 Purge Connector (in bag) Flat head screw driver LP450H0038 Purge Valve Screw (on pump) LP450H0037 Purge Valve (on pump) LP50 Kit Pumps: Place nozzle in container to be filled. Turn on motor. Fill container to desired level. Shut off nozzle. Turn off motor and hang up nozzle. 5

6 TROUBLESHOOTING GUIDE Problem Possible Cause Solution Dirty Strainer screen Remove and clean strainer Suction line problem Check for leaks in suction line O-ring in tank adptor damaged or missing. Inspect and replace o-ring if needed. Pump outlet is blocked or valve is shutoff. Check pump outlet system for blockage. Air trapped in system. Vent air from system (On-demand models have air purge valve) Pump Won't Prime Fluid level below suction pipe. Refill tank or add longer suction pipe. Fluid viscosity exceeds pumps rated capability. Refer to page 7 for viscosity limits Exceeds lift capacity of pump Do not exceed 7 feet of lift for oil Gears are locked. Inspect gears for smooth rotation, remove any debris. Excessive gear wear Inspect gears, replace if worn. Bypass valve not seating Remove/inspect bypass valve, clean if necessary. Shaft key is sheared or missing. Open rotor cover and inspect shaft key. Dirty Strainer screen Remove and clean strainer Suction line problem Check for leaks in suction line Fluid viscosity exceeds pumps rated capability. Refer to page 7 for viscosity limits Outlet system pressure too high. Check outlet system for blockage. Low capacity (low Nozzle or meter has higher pressure flowrate) requirements than what pump is rated for. Replace meter or nozzle. Bypass valve not seating Remove/inspect bypass valve, clean if necessary. Excessive gear wear Inspect gears, replace if worn. Low voltage to motor Ensure power at motor is at proper voltage. Motor stalls when valve/nozzle is closed. Bypass valve is sticking. Remove and inspect bypass valve. Clean if necessary. Motor stalls when Fluid viscosity exceeds pumps rated capability. Refer to page 7 for viscosity limits pump first starts. Gears are locked. Inspect gears for smooth rotation, remove any debris. Fluid viscosity exceeds pumps rated capability. Refer to page 7 for viscosity limits Motor overheats Gears are not rotating smoothly. Inspect gears for smooth rotation, remove any debris. Incorrect voltage Ensure power at motor is at proper voltage. No power to motor Check circuit breakers and electrical connections. Motor will not turn on Switch failure Replace switch. Motor has tripped internal motor protection. Allow motor to cool for at least 30 minutes. Missing or damaged seal Inspect affected area for proper o-ring/gasket. Pumps leaks. Shaft seal damage. Inspect and replace shaft seal if needed. Incompatible fluid pumped. Check fluid compatibility in Owners Manual ON-DEMAND PUMPS ONLY On-demand motor Fluid viscosity exceeds pumps rated capability. Refer to page 7 for viscosity limits turns off before nozzle is closed. System exceeds rated values for pump. Change system pressure or replace pump. Motor runs for ~6 seconds after nozzle is closed Normal operation, no problem On-demand motor Pressure is too low due to air in system. Air in system must be purged. does not turn off Fluid is too light to build up enough pressure. Turn pump off manually. automatically Leak in system allowing pressure to drop. Inspect system line for leaks Check valve not seating properly. Inspect check valve for debris or damage. On-demand motor Periodic charging of system is normal. Shut off motor when not attended 6

7 Table 1: Viscosities Limits - (SSU) Model Name LP50P18Q115 LP50P36Q115 LP50P18Q12 LP200P18Q LP200P36Q LP450P10Q LP650P10Q Maximum Minimum (Start-up) (Start-up) 6,000 N/A 5,000 N/A 2,000 N/A 7,000 N/A 6,000 N/A 6, , Table 2: Viscosities of Common Fluids at Various Temperatures Temp Temp. ATF ISO 46 Deere 10W-30 15W Wt. SAE Wt. 50 Wt SAE 140 ( F) ( C) Mil SSU HyGard Gear Lube Gear Lube Gear Lube N/A N/A 7

8 MAINTENANCE Disconnect all power and relieve pressure by opening nozzle before servicing pump. To keep pump running at its best, periodically perform the following procedures. 1. Check strainer for dirt accumulation. To clean strainer, remove strainer cover (item 18 on page 8) and pull out screen (item 20 ). Clean gasket surface on strainer cover (item 18 ), pump (item C ) and gasket (item 19). Reinstall and tighten strainer cover firmly. 2. Check hose and nozzle for wear or damage. Worn and damaged hoses or nozzles are potential safety hazards and should be replaced. 3. If the rotor cover (item 15) is removed, note that the rotor cover can only be reassembled as shown in the exploded view on page 8. REPAIR To maintain safety, motors that need repair should be taken to an authorized repair shop. Pumps must be thoroughly flushed and drained before being taken in for service. BASIC LP PUMP PARTS LIST (Common to all models) A Pages 9-12 Motor - Model Specific 1 2 LP50H0157 Bypass Cap Assembly 1 3 LP50H0069 Bypass Cap O-Ring 1 B Pages 9-12 Bypass Spring - Model Specific 1 5 LP50G9976 Bypass Valve 1 C Pages 9-12 Pump Housing - Model Specific G8109 O-Ring -124 (Outlet Flange) 1 D Pages 9-12 Check Valve Assembly - Model Specific 1 9 LP50G9927 Outlet Flange 1 10 LP50H0066 Screw 5/16 x 7/8" SHCS (Outlet Fitt.) 2 11 LP50G9974 Lip Seal, Motor Shaft 1 E Pages 9-12 Gear Set - Model Specific 1 13 LP50G9990 Key Shaft 1 14 LP50G9972 O-Ring, Rotor Cover 1 15 LP50G9920 Rotor Cover 1 16 LP50H0219 Screw 5/16-18 x 3/4"SHCS 6 17 LP50G9973 Screw 3/8-16 x 1" SHCS F4370 Strainer Cap F4381 Gasket, Strainer Cap F2665 Stainer Screen F7744 Gasket, Lathe cut (-244) 1 22 LP50H0027 Tank Adapter Quick-Detach 1 23 LP50G9979 O-Ring -232 (Inlet Flange) 1 24 LP50G9924 Inlet Flange 1 25 LP50H0219 Screw 5/16-18 x 3/4"SHCS 2 8

9 MODEL LP50P18Q115 MAX FLOW = 18 qt/min (17 liter/min) MAX PRESSURE = 50 psi (3.4 bar) NOMINAL CURRENT DRAW = VAC LP KIT MODELS 1 702F3400 Elbow 3/4" NPT 1 2 Incl. w/motor Motor Mounting Bracket 1 3 LP50H0027 Quick-Detach Bung Adapter KTG7743 Suction Pipe 1" (Includes item 5-6) 1 5 VP1400F7687 Suction Pipe 1" PVC, Extension 2 6 VP1400F7686 Suction Pipe 1" PVC, Assembly 1 7 LP50G9987 Hose 3/4" ID X 8 feet long 1 8 6U075 3/4" Manual Nozzle 1 9 LP50H0090 Nozzle Cover F7751 Screw 5/16-18 x 1/2" (Nozzle Cover) 2 A LP50G9958 Motor 1/3 HP, 115VAC, 1700 rpm 1 B LP50G9977 Bypass Spring 1 C LP50G9922 Pump Housing 1 D LP50G9980 Check Valve Assembly 1 E LP50G9944 Gear Set 1 LP50G9967 Power Cord 36" long (not shown) 1 MODEL LP50P36Q115 MAX FLOW = 36 qt/min (34 liter/min) MAX PRESSURE = 50 psi (3.4 bar) NOMINAL CURRENT DRAW = VAC 1 702F3400 Elbow 3/4" NPT 1 2 Incl. w/motor Motor Mounting Bracket 1 3 LP50H0027 Quick-Detach Bung Adapter KTG7743 Suction Pipe 1" (Include items 5-6) 1 5 VP1400F7687 Suction Pipe 1" PVC, Extension 2 6 VP1400F7686 Suction Pipe 1" PVC, Assembly 1 7 LP50G9987 Hose 3/4" ID X 8 feet long 1 8 6U075 3/4" Manual Nozzle 1 9 LP50H0090 Nozzle Cover F7751 Screw 5/16-18 x 1/2" (Nozzle Cover) 2 A LP50G9959 Motor 1 HP, 115VAC, 3400 rpm 1 B LP50G9977 Bypass Spring 1 C LP50G9922 Pump Housing 1 D LP50G9980 Check Valve Assembly 1 E LP50G9944 Gear Set 1 LP50G9968 Power Cord 36" long (not shown) 1 9

10 MODEL LP50P18Q12 MAX FLOW = 18 qt/min (17liter/min) MAX PRESSURE = 50 psi (3.4 bar) NOMINAL CURRENT DRAW = 39 12VDC 1 702F3400 Elbow 3/4" NPT 1 2 Incl. w/motor Motor Mounting Bracket 1 3 LP50H0027 Quick-Detach Bung Adapter KTG7743 Suction Pipe 1" (Include items 5-6) 1 5 VP1400F7687 Suction Pipe 1" PVC, Extension 2 6 VP1400F7686 Suction Pipe 1" PVC, Assembly 1 7 LP50G9987 Hose 3/4" ID X 8 feet long 1 8 6U075 3/4" Manual Nozzle 1 9 LP50H0090 Nozzle Cover F7751 Screw 5/16-18 x 1/2" (Nozzle Cover) 2 A LP50G9957 Motor 1/2 HP, 12VDC, 1700 rpm 1 B LP50G9977 Bypass Spring 1 C LP50G9922 Pump Housing 1 D LP50G9980 Check Valve Assembly 1 E LP50G9944 Gear Set 1 10

11 MODEL LP200P18Q MAX FLOW = 18 qt/min (17 liter/min) MAX PRESSURE = 200 psi (13.8 bar) NOMINAL CURRENT DRAW = VAC NOMINAL CURRENT DRAW = 6 230VAC FACTORY WIRED FOR 115VAC LP BULK TRANSFER MODELS 1 Incl. w/motor Motor Mounting Bracket 1 2 LP50H0027 Quick-Detach Bung Adapter 1 A LP450G9960 Motor 1 HP, 115VAC, 1700 rpm 1 B LP200H0067 Bypass Spring 1 C LP50G9922 Pump Housing 1 D LP50G9980 Check Valve Assembly 1 E LP50G9944 Gear Set 1 MODEL LP200P36Q MAX FLOW = 36 qt/min (34 liter/min) MAX PRESSURE = 200 psi (13.8 bar) NOMINAL CURRENT DRAW = VAC NOMINAL CURRENT DRAW = VAC FACTORY WIRED FOR 230VAC NOTE: Not recommended for use with 115VAC power unless circuit is fitted with appropriate breaker and wire size to handle motor load. 1 Incl. w/motor Motor Mounting Bracket 1 2 LP50H0027 Quick-Detach Bung Adapter 1 A LP200G9962 Motor 2 HP, 115/230 VAC, 3400 rpm 1 B LP200H0067 Bypass Spring 1 C LP50G9922 Pump Housing 1 D LP50G9980 Check Valve Assembly 1 E LP50G9944 Gear Set 1 11

12 LP ON-DEMAND PUMP MODEL LP450P10Q MAX FLOW = 10 qt/min (9.5 liter/min) MAX PRESSURE = 450 psi (31 bar) NOMINAL CURRENT DRAW = 115VAC NOMINAL CURRENT DRAW = VAC PRESSURE SENSING ON/OFF SWITCH = Set at 400 psi FACTORY WIRED FOR 115VAC 1 Incl. w/motor Motor Mounting Bracket 1 2 LP50H0027 Quick-Detach Bung Adapter 1 A LP450G9960 Motor 1 HP, 115/230 VAC, 1700 rpm 1 B LP450H0068 Bypass Spring 1 C LP450G9947 Pump Housing 1 D LP450H0092 Check Valve Assembly 1 E LP50G9945 Gear Set 1 MODEL LP650P10Q MAX FLOW = 10 qt/min (9.5 liter/min) MAX PRESSURE = 650 psi (44.8 bar) NOMINAL CURRENT DRAW 115VAC NOMINAL CURRENT DRAW = VAC PRESSURE SENSING ON/OFF SWITCH = Set at 650 psi FACTORY WIRED FOR 230VAC NOTE: Not recommended for use with 115VAC power unless circuit is fitted with appropriate breaker and wire size to handle motor load. 1 Incl. w/motor Motor Mounting Bracket 1 2 LP50H0027 Quick-Detach Bung Adapter 1 A LP650G9961 Motor 1 1/2 HP,115/230VAC,1700 rpm 1 B LP200H0067 Bypass Spring 1 C LP450G9947 Pump Housing 1 D LP450H0092 Check Valve Assembly 1 E LP50G9945 Gear Set 1 12

13 Fill-Rite: A Worldwide Reputation for Reliability. For over 40 years, people all over the world who have needed tough, dependable pumps have insisted on Fill- Rite products. For them, Fill-Rite has been the reliable red pump that keeps on working even under the toughest of conditions. We re proud of the reputation our hand pumps, DC and AC pumps and meters have earned. Today they re only a part of the rapidly expanding Fill-Rite line. Applying the Science of Fluid Transfer. An active research and development program is the centerpiece of our ongoing commitment to respond to new fluid transfer opportunities. This has led to new products and to new technologies and new facilities to produce these products. To bring this advanced technology to market, we have invested in precision engineering and testing equipment. This improves our ability to produce fluid handling equipment that meets market demands for quality, performance and price. A Hard Working Support Network. Just as important as these capabilities are the people behind them - our design and production personnel. They give you the ability to specify systems that meet the most challenging of applications. With them, you can be assured of prompt, intelligent answers to your fluid transfer questions. To service customers in the field, we ve put together a select, well-monitored team of distributors. Throughout the world, they are ready to help you with technical advice, ordering and delivery. Fill-Rite will always stand for reliable red pumps and fluid handling equipment. We ll continue to develop new products and production techniques to keep pace with ever changing technologies. Each of our products will always be made with the same care and quality that made our pumps famous. PRODUCT WARRANTY Tuthill Transfer Systems ( Manufacturer ) warrants to each consumer buyer of its Fill-Rite products (the Buyer ), from the date of invoice or sales receipt, that goods of its manufacture ( Goods ) will be free from defects of material and workmanship. Duration of this warranty is as follows: Heavy Duty Products - Two years Standard Duty Products One year Economy Duty Products One year Lube Transfer Products One year Cabinet pumps, Parts, and Accessories - One year Manufacturer s sole obligation under the foregoing warranties will be limited to either, at Manufacturers option, replacing or repairing defective Goods (subject to limitations hereinafter provided) or refunding the purchase price for such Goods theretofore paid by the Buyer, and Buyer s exclusive remedy for breach of any such warranties will be enforcement of such obligations of Manufacturer. If Manufacturer so requests the return of the Goods, the Goods will be redelivered to Manufacturer in accordance with Manufacturer s instructions F.O.B. Factory. The remedies contained herein shall constitute the sole recourse of the Buyer against Manufacturer for breach of warranty. IN NO EVENT SHALL MANUFACTURER S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF THE MANUFACTURE, SALE, DELIVERY, OR USE OF THE GOODS EXCEED THE PURCHASE PRICE OF THE GOODS. The foregoing warranties will not extend to Goods subjected to misuse, neglect, accident or improper installation or maintenance, or which have been altered or repaired by anyone other than Manufacturer or its authorized representative. THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES OF MERCHANTABILITY, FITNESS FOR PURPOSE OF ANY OTHER TYPE, WHETHER EXPRESS OR IMPLIED. No person may vary the foregoing warranties and remedies except in writing signed by a duly authorized officer of Manufacturer. Warranties or remedies that differ from the foregoing shall not otherwise be binding on Manufacturer. The Buyer s acceptance of delivery of the Goods constitutes acceptance of the foregoing warranties and remedies, and all conditions and limitations thereof. LP50G9954 rev 1 13

S T O P. Oil Pump. Models L 5016, L 5116 and L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

S T O P. Oil Pump. Models L 5016, L 5116 and L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS SAVE THESE INSTRUCTIONS Oil Pump Models L 5016, L 5116 and L 5132 Owner s Manual 5252 East 36th Street North Wichita, KS USA 67220-3205 TEL: 316-686-7361 FAX: 316-686-6746 A Great Plains Ventures Subsidiary

More information

STOP. Oil Pump Models L 5016, L 5116 & L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

STOP. Oil Pump Models L 5016, L 5116 & L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS SAVE THESE INSTRUCTIONS 5252 East 36th Street North Wichita, KS USA 67220-3205 TEL: 316-686-7361 FAX: 316-686-6746 Oil Pump Models L 5016, L 5116 & L 5132 Owner s Manual STOP DO NOT RETURN THIS PRODUCT

More information

Oil Pump Models L 5016, L 5116 & L 5132

Oil Pump Models L 5016, L 5116 & L 5132 SAVE THIS OWNER S MANUAL Oil Pump Models L 5016, L 5116 & L 5132 Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! Please contact GPI before returning any product. If you are missing parts or experience

More information

SERIES 300V 115 and 230 VOLT AC FUEL TRANSFER PUMP Owner's Operation & Safety Manual Models FR300V, FR301V, FR310V & FR311V

SERIES 300V 115 and 230 VOLT AC FUEL TRANSFER PUMP Owner's Operation & Safety Manual Models FR300V, FR301V, FR310V & FR311V SERIES 300V 115 and 230 VOLT AC FUEL TRANSFER PUMP Owner's Operation & Safety Manual Models FR300V, FR301V, FR310V & FR311V SAFETY INSTRUCTIONS To ensure safe and effi cient operation, it is essential

More information

305 REMOTE DISPENSER

305 REMOTE DISPENSER Owner's Operation & Safety Manual 305 REMOTE DISPENSER Model 305RU OUTSTANDING FEATURES From 6 to 40 GPM / 23 to151 LPM Meter accuracy of ± 2% GENERAL DESCRIPTION Dear Fill-Rite Customer, Thank you for

More information

SERIES 38 VOLUMETRIC HAND PUMPS For models 38, 38C, 38L, 38CL

SERIES 38 VOLUMETRIC HAND PUMPS For models 38, 38C, 38L, 38CL Owner's Operation & Safety Manual SERIES 38 VOLUMETRIC HAND PUMPS For models 38, 38C, 38L, 38CL Model 38 Model 38C OUTSTANDING FEATURES Visible pumping chamber Accurately dispense one quart or one liter

More information

SERIES FR400 DIAPHRAGM PUMP

SERIES FR400 DIAPHRAGM PUMP Owner's Manual SERIES FR400 DIAPHRAGM PUMP For Industrial Fluid Transfer For models: FR405, FR410, FR412, FR205, FR210, FR212 (DC) & FR450, FR450E, FR452 (AC) Model FR410 Patent #5,219,274 DANGER EXPLOSION

More information

Remote Dispensing Cabinet 902V Series Cabinet Dispenser

Remote Dispensing Cabinet 902V Series Cabinet Dispenser Owners Installation, Operation, and Safety Manual Remote Dispensing Cabinet 902V Series Cabinet Dispenser Models FR902R, non-ul, gallon FR902LR, non-ul, liter FR902RU, UL, cul listed, gallon FR902LRU,

More information

FR1118- P10. User s Manual

FR1118- P10. User s Manual FR1118- P10 User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious personal injury.

More information

Stealth Electronic Manual ZTM1015 Installation & Maintenance. For Oval Gear Meter Models:

Stealth Electronic Manual ZTM1015 Installation & Maintenance. For Oval Gear Meter Models: Stealth Electronic Manual ZTM05 Installation & Maintenance For Oval Gear Meter Models: TS0 TS5 TS0 TS30 including : CC56 PIA EDB 80 PC58 PCDT58 PDB 80 DU53 PRT PDMB 80 ELNC PAC PMFC Meter Model No.: TS

More information

G8 Portable Fuel Transfer Pump Owner s Manual

G8 Portable Fuel Transfer Pump Owner s Manual G8 Portable Fuel Transfer Pump Owner s Manual GENERAL INFORMATION This pump is designed for use only with gasoline (up to 15% alcohol blends such as E15), diesel fuel (up to 20% biodiesel blends such as

More information

OWNER S MANUAL STOP. Models: Blade Master 1.5 HP 1500 Series Stationary Transfer Pump 1.5 Pump, Single Phase AC 110/220V, Non-Explosion proof

OWNER S MANUAL STOP. Models: Blade Master 1.5 HP 1500 Series Stationary Transfer Pump 1.5 Pump, Single Phase AC 110/220V, Non-Explosion proof SAVE THESE INSTRUCTIONS Models: 02-1514-GII, 02-1520-GII, 02-1521-GII, 02-1522-GII Blade Master 1.5 HP 1500 Series Stationary Transfer Pump 1.5 Pump, Single Phase AC 110/220V, Non-Explosion proof OWNER

More information

Stealth Electronic Manual ZTM1010 Installation & Maintenance. For Oval Gear Meter Models:

Stealth Electronic Manual ZTM1010 Installation & Maintenance. For Oval Gear Meter Models: Stealth Electronic Manual ZTM1010 Installation & Maintenance For Oval Gear Meter Models: TS10 TS15 TS20 TS30 including : CC56 PIA EDB 180 PC58 PCDT58 PDB 180 DU53 PRT PDMB 180 ELNC PAC PMFC Meter Model

More information

Electric Fuel Pump FPM

Electric Fuel Pump FPM INSTRUCTION MANUAL Electric Fuel Pump FPM S1590, Rev B LISTED MOTOR FPM-12, FPM-24, FPM-115, FPM-220 Congratulations on purchase of this World Class Electric Fuel Pump! Elbow This is an Electric Fuel Pump.

More information

HALLMARK INDUSTRIES INC

HALLMARK INDUSTRIES INC Performance Part No. HP. CONVERTIBLE JET PUMP USER S MANUAL GPH of Water @ Total Discharge Pressure of 40 psi Max. Pressure Max suction (shallow well) Max Suction (deep well) Max GPM (@0 head) Max Discharge

More information

MR 5-30 Aviation Fuel Meter Owner s Manual

MR 5-30 Aviation Fuel Meter Owner s Manual SAVE THESE INSTRUCTIONS 5252 East 36th Street North Wichita, KS USA 67220-3205 TEL: 316-686-7361 FAX: 316-686-6746 MR 5-30 Aviation Fuel Meter Owner s Manual TABLE OF CONTENTS General Information... 2

More information

P-200 Plastic Utility Pump for Petroleum Products

P-200 Plastic Utility Pump for Petroleum Products P-200 Plastic Utility Pump for Petroleum Products Owner s Manual 5252 East 36th Street North Wichita, KS USA 67220-3205 TEL: 316-686-7361 FAX: 316-686-6746 A Great Plains Ventures Subsidiary www.gpi.net

More information

ILLUSTRATED PARTS LIST

ILLUSTRATED PARTS LIST ILLUSTRATED PARTS LIST 14 13 12 M-3130-RDP ONLY 33 11 9 10 15 8 1 2 3 16 5 17 6 7 22 29 30 4 28 26 32 18 31 19 20 21 23 25 27 24 Item No. No. Part No. Description Req d. 6 1 904006-38 Hex Head Screw 3/8-16

More information

STOP. M-3130 & M-3130-RDP Series. 115/230 Volt Super Duty Fuel Pumps. Owner s Manual. M-3130-PO Pump Only DO NOT RETURN THIS PRODUCT TO THE STORE!

STOP. M-3130 & M-3130-RDP Series. 115/230 Volt Super Duty Fuel Pumps. Owner s Manual. M-3130-PO Pump Only DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS M-3130 & M-3130-RDP Series 115/230 Volt Super Duty Fuel Pumps M-3130-ML Manual Nozzle M-3130-PO Pump Only Owner s Manual STOP DO NOT RETURN THIS PRODUCT TO THE STORE! Please contact

More information

M-3025CB-AV Fuel Pump

M-3025CB-AV Fuel Pump SAVE THESE INSTRUCTIONS M-3025CB-AV Fuel Pump Owner s Manual TABLE OF CONTENTS General Information... 2 Safety Instructions... 2 Installation... 3 Operation... 4 Maintenance... 4 Repair... 5 Troubleshooting...

More information

M-3130 & M-3130-RDP Series 115/230 Volt Super Duty Fuel Pump M-3130-ML Manual Nozzle M-3130-AL Automatic Nozzle M-3130-PO Pump Only Owner s Manual

M-3130 & M-3130-RDP Series 115/230 Volt Super Duty Fuel Pump M-3130-ML Manual Nozzle M-3130-AL Automatic Nozzle M-3130-PO Pump Only Owner s Manual SAVE THESE INSTRUCTIONS M-3130 & M-3130-RDP Series 115/230 Volt Super Duty Fuel Pump M-3130-ML Manual Nozzle M-3130-AL Automatic Nozzle M-3130-PO Pump Only Owner s Manual 5252 East 36th Street North Wichita,

More information

12 Volt DC Diaphragm Pumps Series 400

12 Volt DC Diaphragm Pumps Series 400 Page 1 of 6 12 Volt DC Diaphragm Pumps Series 400 More Information Index Description of Included Models Safety Listings Available Options Accessories Performance Flow Curve Fluid Compatibility Dimensions

More information

M-1115S Series Fuel Pump

M-1115S Series Fuel Pump SAVE THESE INSTRUCTIONS M-1115S Series Fuel Pump Owner s Manual TABLE OF CONTENTS General Information...2 Safety Instructions...2 Installation...3 Operation...4 Maintenance...5 Repair...5 Troubleshooting...9

More information

VP12 High Viscosity Piston Pump

VP12 High Viscosity Piston Pump 5252 East 36th Street North Wichita, KS USA 67220-3205 TEL: 316-686-7361 FAX: 316-686-6746 VP12 High Viscosity Piston Pump Owner s Manual A Great Plains Ventures Subsidiary www.gpi.net 1-800-835-0113 INSTALLATION

More information

ESE Series Cast Iron Sewage Pumps

ESE Series Cast Iron Sewage Pumps Owner s Manual ESE Series Cast Iron Sewage Pumps TABLE OF CONTENTS General Safety.................... 2 Specifications..................... 3 Installation.................... 4 & 5 Troubleshooting...................

More information

STOP. M-150S-Methanol Pump Owner s Manual SAVE THESE INSTRUCTIONS DO NOT RETURN THIS PRODUCT TO THE STORE! TABLE OF CONTENTS

STOP. M-150S-Methanol Pump Owner s Manual SAVE THESE INSTRUCTIONS DO NOT RETURN THIS PRODUCT TO THE STORE! TABLE OF CONTENTS SAVE THESE INSTRUCTIONS 5252 East 36th Street North Wichita, KS USA 67220-3205 TEL: 316-686-7361 FAX: 316-686-6746 M-150S-Methanol Pump Owner s Manual STOP DO NOT RETURN THIS PRODUCT TO THE STORE! Please

More information

PRE-PLUMBED SEWAGE SYSTEM

PRE-PLUMBED SEWAGE SYSTEM PRE-PLUMBED SEWAGE SYSTEM Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1910-0009 Español p. 13 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems,

More information

PRO PRO20-115RD 115-Volt AC. PRO Volt AC OWNER'S MANUAL SAVE THESE INSTRUCTIONS

PRO PRO20-115RD 115-Volt AC. PRO Volt AC OWNER'S MANUAL SAVE THESE INSTRUCTIONS OWNER'S MANUAL SAVE THESE INSTRUCTIONS PRO20-115 PRO20-115RD 115-Volt AC PRO20-115AD Automatic Diesel Nozzle PRO20-115MD Manual Diesel Nozzle PRO20-115PO Pump Only PRO20-115RD For Remote Dispensing Systems

More information

Owner's Operation & Safety Manual SERIES 800C METER. For models 806C, 807C OUTSTANDING FEATURES

Owner's Operation & Safety Manual SERIES 800C METER. For models 806C, 807C OUTSTANDING FEATURES Owner's Operation & Safety Manual SERIES 800C METER For models 806C, 807C Model 806C Model 807C OUTSTANDING FEATURES 5 to 20 GPM / 19 to 76 LPM flow rate ±1% accuracy 3/4" or 1" NPT flow ports Large, easy

More information

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS Model 31801 and 31800 Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS INDUSTRIAL DIAPHRAGM PUMPS FEATURES Run Dry Ability Self-Priming Thermal Overload Protected Motor Easy Installation Low Amp Draw Compact

More information

Operators Manual. Recirculating Chiller /06/08

Operators Manual. Recirculating Chiller /06/08 Operators Manual Recirculating Chiller 110-197 11/06/08 Table of Contents Section 1. General Information 1.1 Warranty 1.2 Unpacking 1.3 Package Contents 1.4 Description of the Recirculating Chiller 1.5

More information

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09 HAND CRANK & MOTORIZED POWER CORD REELS: SERIES 1125PC SERIES: 1125PC HAND CRANK SERIES: 1125PC MOTORIZED COXREELS The technical data and images which appear in this manual are for informational purposes

More information

STOP. LP-50DEF-BRL Lever Hand Pump System Barrel Mounting. Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS

STOP. LP-50DEF-BRL Lever Hand Pump System Barrel Mounting. Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS SAVE THESE INSTRUCTIONS LP-50DEF-BRL Lever Hand Pump System Barrel Mounting Owner s Manual 5252 East 36th Street North Wichita, KS USA 67220-3205 316-686-7361 FAX: 316-686-6746 800-835-0113 www.gpipumps.net

More information

MR 5-30 or MR 5-30N Series Fuel Meter Owner s Manual

MR 5-30 or MR 5-30N Series Fuel Meter Owner s Manual SAVE THESE INSTRUCTIONS 5252 East 36th Street North Wichita, KS USA 67220-3205 316-686-7361 FAX: 316-686-6746 800-835-0113 www.gpipumps.net A Great Plains Ventures Subsidiary MR 5-30 or MR 5-30N Series

More information

DC 12V 8GPM Fuel Transfer Pump Kit User s Manual

DC 12V 8GPM Fuel Transfer Pump Kit User s Manual DC V GPM Fuel Transfer Pump Kit User s Manual Distributed by: TRACTOR SUPPLY COMPANY 0 VIRGINIA WAY BRENTWOOD, TN 0 For customer support, call: ---90 www.tractorsupply.com MADE IN CHINA MODEL NUMBER: 0

More information

Product Owner s Manual. 8 GPM / 30 LPM, 12-volt Fuel Transfer Pump. Model G8P

Product Owner s Manual. 8 GPM / 30 LPM, 12-volt Fuel Transfer Pump. Model G8P Product Owner s Manual EN 8 GPM / 30 LPM, 12-volt Fuel Transfer Pump Model G8P 05/2017 922130-01 Rev. A THANK YOU STATEMENT GOES HERE: Please save these instructions for future reference. Read carefully

More information

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS PumpAgents.com - Click here for Pricing/Ordering Model 36600-Series ELECTRIC BILGE PUMPS FEATURES Self-Priming Diaphragm Design Allows Dry Running Quiet Operation Built-in Hydraulic Pulsation Dampener

More information

M-3020 FUEL PUMP OWNER S MANUAL TABLE OF CONTENTS DO NOT RETURN THIS PRODUCT TO THE STORE! Please contact. Great Plains Industries, Inc.

M-3020 FUEL PUMP OWNER S MANUAL TABLE OF CONTENTS DO NOT RETURN THIS PRODUCT TO THE STORE! Please contact. Great Plains Industries, Inc. M-3020 FUEL PUMP OWNER S MANUAL DO NOT RETURN THIS PRODUCT TO THE STORE! Please contact Great Plains Industries, Inc. before returning any product. If you are missing parts, or experience problems with

More information

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual SAVE THESE INSTRUCTIONS M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual TABLE OF CONTENTS General Information...2 Safety Instructions...2 Installation...2

More information

Electric Fuel Pump FPM

Electric Fuel Pump FPM INSTRUCTION MANUAL Electric Fuel Pump FPM S1590, Rev B LISTED MOTOR FPM-12, FPM-12/HF, FPM-24, FPM-115, FPM-220 Congratulations on purchase of this World Class Electric Fuel Pump! Pump Outlet Elbow Nozzle

More information

CRD610 Automatic Fitting Inserter

CRD610 Automatic Fitting Inserter CRD610 Automatic Fitting Inserter OPERATIONS MANUAL VERSION 1.2 LAST EDITED 12.12.2018 cleanroomdevices.com 1 Table of Contents Title Page. 1 Table of Contents...2 1.0 General Product & Safety Information....3

More information

M-3020 STOP. Owner s Manual SAVE THESE INSTRUCTIONS TABLE OF CONTENTS DO NOT RETURN THIS PRODUCT TO THE STORE!

M-3020 STOP. Owner s Manual SAVE THESE INSTRUCTIONS TABLE OF CONTENTS DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS M-3020 Owner s Manual STOP DO NOT RETURN THIS PRODUCT TO THE STORE! Please contact GPI before returning any product. If you are missing parts or experience problems with your installation,

More information

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13 GRINDER PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #2701-0005 Español p. 13 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing parts?

More information

STOP. Contractor Special Fuel Pumps. Heavy Duty Fuel Pumps. Use this manual with: M-3425CS 24-Volt DC. M Volt DC & M Volt DC

STOP. Contractor Special Fuel Pumps. Heavy Duty Fuel Pumps. Use this manual with: M-3425CS 24-Volt DC. M Volt DC & M Volt DC SAVE THESE INSTRUCTIONS 5252 East 36th Street North W ichita, KS USA 67220-3205 TEL: 316-686-7361 FAX: 316-686-6746 Use this manual with: Heavy Duty Fuel Pumps M-3025 12-Volt DC & M-3425 24-Volt DC MODELS:

More information

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including

More information

Installation & Operation Manual. Electrak 10 Series / Electromechanical Linear Actuator

Installation & Operation Manual. Electrak 10 Series / Electromechanical Linear Actuator www..com Installation & Operation Manual Electrak 10 Series / Electromechanical Linear Actuator INTRODUCTION Thomson has many years of experience designing and manufacturing linear actuators for a wide

More information

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL MODEL #VP05, VP10 C US NSF/ANSI 372 255405 For loose, missing or damaged parts, or if the unit does not seem to be operating properly, please call before returning

More information

M-1115S Series Fuel Pump

M-1115S Series Fuel Pump SAVE THESE INSTRUCTIONS 5252 East 36th Street North W ichita, KS USA 67220-3205 TEL: 316-686-7361 FAX: 316-686-6746 M-1115S Series Fuel Pump Owner s Manual TABLE OF CONTENTS General Information...2 Installation...3

More information

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE QUICK START GUIDE OWNER S MANUAL SAFETY, INSTALLATION, OPERATION & PARTS AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL 877-278-2797 DO NOT RETURN TO STORE! WARNING This equipment must be installed

More information

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14 SEWAGE PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1261-0001 Español p. 14 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing parts?

More information

Model &

Model & PumpAgents.com - Click here for Pricing/Ordering Model 31765-0092 & 31765-0094 Dual Sensor Max VSD WATER PRESSURE SYSTEM AUTOMATIC TWO STAGE WATER SYSTEM WITH PUMPGARD STRAINERS IDEAL FOR PLEASURE AND

More information

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

CLEAN ROOM DEVICES, LLC WHERE TUBING AND FITTINGS COME TOGETHER CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER" CRD600 Automatic Fitting Inserter OPERATIONS MANUAL VERSION 2.1 LAST EDITED 7.25.14 DOCUMENT NUMBER 001 cleanroomdevices.com 1 Table of

More information

Model 1210C Battery Powered Pump Shown

Model 1210C Battery Powered Pump Shown Page 1 of 6 PRODUCT DATA SHEET 12 Volt DC Rotary Vane Pump Series 1200C Description of Included Models Available Options Safety Listings Accessories Performance Flow Curve Fluid Compatibility Dimensions

More information

SERIES FR400 DIAPHRAGM PUMP

SERIES FR400 DIAPHRAGM PUMP Owner's Manual SERIES FR400 DIAPHRAGM PUMP For Industrial Fluid Transfer For models: FR405, FR410, FR412, FR205, FR210, FR212 (DC) & FR450, FR450E, FR452 (AC) Model FR410 Patent #5,219,274 DANGER EXPLOSION

More information

PPM EO-100 TM. Operation Manual

PPM EO-100 TM. Operation Manual PPM EO-100 TM Open Loop Electric Prewet Power Module Operation Manual Rev A Page 1 2/23/2010 Copyright 2008 by Cirus Controls, LLC. All Rights Reserved. No part of this material may be reproduced in any

More information

M-150S, M-180S. and M-240S Fuel Pump. Owner s Manual SAVE THESE INSTRUCTIONS TABLE OF CONTENTS DO NOT RETURN THIS PRODUCT TO THE STORE!

M-150S, M-180S. and M-240S Fuel Pump. Owner s Manual SAVE THESE INSTRUCTIONS TABLE OF CONTENTS DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS M-150S, M-180S and M-240S Fuel Pump Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! Please contact GPI before returning any product. If you are missing parts or experience

More information

PRODUCT: 1500 SERIES MOBILE EXPLOSION PROOF PAGE 1 REV "BLADE MASTER" AC-EP-SINGLE PHASE-1.5 HP OPERATING AND MAINTENANCE INSTRUCTIONS

PRODUCT: 1500 SERIES MOBILE EXPLOSION PROOF PAGE 1 REV BLADE MASTER AC-EP-SINGLE PHASE-1.5 HP OPERATING AND MAINTENANCE INSTRUCTIONS PRODUCT: 1500 SERIES MOBILE EXPLOSION PROOF PAGE 1 REV.020112 "BLADE MASTER" AC-EP-SINGLE PHASE-1.5 HP OPERATING AND MAINTENANCE INSTRUCTIONS The "Blade Master is a high-volume, low-energy, (U.L. /C.S.A.,

More information

Operators Manual. Model 3370 Air Cooled Recirculator rev.8/98

Operators Manual. Model 3370 Air Cooled Recirculator rev.8/98 Operators Manual Model 3370 Air Cooled Recirculator 110-080 rev.8/98 Table of contents Section 1. General Information 1.1 Warranty 1.2 Unpacking Section 2. Product Information 2.1 Description 2.2 Specification

More information

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps INSTALLATION MANUAL Series: 1/12HP, 5000 RPM, 60 Hz ISP No: - 6/09 General Safety Information Before installation, read the following instructions carefully. Failure to follow instruction and Safety information

More information

M-150S, M-180S & M-240S FUEL PUMP

M-150S, M-180S & M-240S FUEL PUMP M-150S, M-180S & M-240S FUEL PUMP OWNER S MANUAL DO NOT RETURN THIS PRODUCT TO THE STORE! Please contact Great Plains Industries, Inc. before returning any product. If you are missing parts, or experience

More information

F PRO. 12 Volt Electric Sprayer. Part #AS76 Copyright 2014 by Hydro-Force Rev. 1/14

F PRO. 12 Volt Electric Sprayer. Part #AS76 Copyright 2014 by Hydro-Force Rev. 1/14 F PRO SPRAYER by 12 Volt Electric Sprayer Part #AS76 Copyright 2014 by Hydro-Force Rev. 1/14 Table of Contents Feature and Benefits... 3 Specifications... 3 Complete Sprayer Diagram... 4 Complete Sprayer

More information

EZ-8 & EZ-8 METHANOL FUEL PUMP

EZ-8 & EZ-8 METHANOL FUEL PUMP EZ-8 & EZ-8 METHANOL FUEL PUMP OWNER S MANUAL DO NOT RETURN THIS PRODUCT TO THE STORE! Please contact Great Plains Industries, Inc. before returning any product. If you are missing parts, or experience

More information

PT-516 Pumping Trap Installation and Maintenance

PT-516 Pumping Trap Installation and Maintenance PT-516 Pumping Trap Installation and Maintenance IB-104-B This bulletin should be used by experienced personnel as a guide to the installation and maintenance of the PT-516 Pumping Trap or Pumping Trap

More information

OWNER S MANUAL. Model 9214 HIGH OUTPUT 12 VOLT TRANSFER PUMP /06 10/17

OWNER S MANUAL. Model 9214 HIGH OUTPUT 12 VOLT TRANSFER PUMP /06 10/17 OWNER S MANUAL Model 9214 HIGH OUTPUT 12 VOLT TRANSFER PUMP 9214 5/06 10/17 Introduction Congratulations on purchasing a Harvest Tec Model 9214 transfer pump. This system is designed to transfer Harvest

More information

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

CLEAN ROOM DEVICES, LLC WHERE TUBING AND FITTINGS COME TOGETHER CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER" CRD600AF Automatic Fitting Inserter With Auto Feed OPERATIONS MANUAL (Shown with optional alcohol dispenser) 1 VERSION 1.1 LAST EDITED

More information

SUNC3000 / Item #40885

SUNC3000 / Item #40885 SUNC3000 / Item #40885 AUTOMATIC POOL COVER PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM 1 . Performance GPH of Water @ Total Feet Of Lift MODEL HP Max. Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. SUNC3000 1/3

More information

Model FR610C Pump Shown. Suction Pipe, 1/4 HP VAC/60 HZ Motor, and Model 807C1 Meter Installed.

Model FR610C Pump Shown. Suction Pipe, 1/4 HP VAC/60 HZ Motor, and Model 807C1 Meter Installed. Series 600 AC Powered Pumps Model FR610C Pump Shown of Included Models Model Number FR610C FR611C Heavy Duty AC Utility Pump with 3/4" X 12' Hose & Nozzle, Telescoping Suction Pipe and 1/4 HP - 115 VAC/60

More information

StormPro BA Series Sump Pump

StormPro BA Series Sump Pump Page 1 of 8 Marks & Meanings DANGER: Keep the pump equipment out of the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects. WARNING:

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS OWNER S MANUAL FLO-MASTER XP2 SERIES PUMPS IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:

More information

FR600G Series AC Transfer Pumps

FR600G Series AC Transfer Pumps Owners Installation, Operation, and Safety Manual FR1200G / FR2400G / FR4200G / FR4400G SD1200G / Series DC Transfer Pumps FR600G Series AC Transfer Pumps 1 Tuthill Transfer Systems 8825 Aviation Drive

More information

PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS

PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL 62545 Telephone: 217 / 364-4467 Fax: 217 / 364-4494 OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS WHAT TO DO FIRST Upon receiving your new pump set system

More information

INSTRUCTIONS PARTS LIST This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE

INSTRUCTIONS PARTS LIST This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE INSTRUCTIONS PARTS LIST 308 493 This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE Rev. A Second Gun Hose Kit 100 psi (6.9 bar) Maximum Working Pressure These kits include

More information

PumpAgents.com - Click here for Pricing/Ordering Fuse Size (A) Open Flow GPM (LPM)

PumpAgents.com - Click here for Pricing/Ordering Fuse Size (A) Open Flow GPM (LPM) PumpAgents.com - Click here for Pricing/Ordering Models 41700 / 51700 - Series Washdown Pump WASHDOWN PUMP 0 PSI (5.5 BAR) 7.5 GPM (29 LPM) 6.0 GPM (23 LPM) FEATURES High Pressure / High capacity Pumpgard

More information

FLEX VANE IMPELLER MODEL 3000-XXX Replacement Parts Kit Instructions

FLEX VANE IMPELLER MODEL 3000-XXX Replacement Parts Kit Instructions FLEX VANE IMPELLER MODEL 3000-XXX Replacement Parts Kit Instructions WARNING:Do not pump flammable liquids! Model 3000 pumps (Buna impeller) are suitable for non-potable water, automotive oil, automatic

More information

FR1200G / FR2400G / FR4200G / FR4400G SD1200G / Series DC Transfer Pumps

FR1200G / FR2400G / FR4200G / FR4400G SD1200G / Series DC Transfer Pumps Owners Installation, Operation, and Safety Manual FR1200G / FR2400G / FR4200G / FR4400G SD1200G / Series DC Transfer Pumps FR600G Series AC Transfer Pumps 1 Tuthill Transfer Systems 8825 Aviation Drive

More information

INSTALLATION INSTRUCTIONS, PARTS LIST AND CONFIGURATION GUIDE FOR THE CARBONATOR. Large Model No

INSTALLATION INSTRUCTIONS, PARTS LIST AND CONFIGURATION GUIDE FOR THE CARBONATOR. Large Model No Please refer to the Schroeder America website (www.schroederamerica.com) for information relating to Schroeder America installation and Service Manuals, Instruction Sheets, Technical Bulletins, Service

More information

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP OWNER S MANUAL Pond Pump READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP Important Notice: This manual contains important information about the installation, operation and safe use of this product. This

More information

Owners Installation, Operation, and Safety Manual

Owners Installation, Operation, and Safety Manual Owners Installation, Operation, and Safety Manual Remote Dispensing Cabinets Models FR102PH FR302DP FR902DP FR910PM Tuthill Corporation 8825 Aviation Drive Ft. Wayne, IN 46809 (260) 747-7529 www.tuthill.com

More information

Marlow Series Cast Iron Swimming Pool Pumps

Marlow Series Cast Iron Swimming Pool Pumps INSTRUCTION MANUAL SECTION 360A AC1683 REVISION C INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER'S USE. Marlow Series Cast Iron Swimming Pool Pumps 3B28EC 3B32EC PLEASE FILL IN DATA FROM YOUR PUMP NAMEPLATE

More information

Ph: (07) Fax: (07) Pump Manual

Ph: (07) Fax: (07) Pump Manual sales@scintex.com.au www.scintex.com.au Ph: (07) 3137 0135 Fax: (07) 3041 0541 Pump Manual 12V 75LPM Vane Pump & Vane Pump Station SPEP12V75 & SP12VFS75 SPEP12V75 SP12VFS75 Parts List No. Part Name QTY

More information

CRD600 Automatic Fitting Inserter

CRD600 Automatic Fitting Inserter CRD600 Automatic Fitting Inserter OPERATIONS MANUAL VERSION 2.3 LAST EDITED 12.07.2018 cleanroomdevices.com 1 Table of Contents Title Page.. 1 Table of Contents. 2 1.0 General Product & Safety Information...3

More information

SUPER PUMP OUT SYSTEM

SUPER PUMP OUT SYSTEM Congratulations on your purchase of the SUPER PUMP OUT SYSTEM. This instruction/parts manual is a guide for operating and servicing your BLUELINE SUPER PUMP OUT SYSTEM. Proper operation and service are

More information

DSTP20: Fuel Transfer Pump

DSTP20: Fuel Transfer Pump DSTP20: Fuel Transfer Pump Up To 20 GPM Integral inlet screen 2 Male NPT On Bung Adapter Security: Pump equipped for padlocking Ball Bearing Construction, No Lubrication Required Dimensions: 14" wide x

More information

PreSoak System (NonFoaming) DU PS1-HP DU PS6-HP

PreSoak System (NonFoaming) DU PS1-HP DU PS6-HP PreSoak System (NonFoaming) DU PS1-HP DU PS6-HP Serial Number: Owner s Manual #0786 040810 Installation Date: Please read and u n d e r s t a n d t h i s manual. Store in safe location for future reference.

More information

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST Horizontal Multi-Stage Jet Pumps HMS-1FL Series MODELS 3/4 HP 1 HP 1-1/2 HP HMSD-1FL HMSE-1FL HMSF-1FL STA-RITE INDUSTRIES 293 Wright

More information

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP TM 42371 Avenida Alvarado Temecula, CA 92590 TOLL FREE (800) 454-2725 TEL (951) 296-3480 FAX (951) 296-3490 www.aquauv.com Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP Sunami Warranty

More information

AUTOMATIC SUBMERSIBLE UTILITY PUMP

AUTOMATIC SUBMERSIBLE UTILITY PUMP AUTOMATIC SUBMERSIBLE UTILITY PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1043-0006 Español p. 9 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems,

More information

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5 MODELS 282050, 282716 & 283513 AIR OPERATED CHASSIS PUMP SERIES A OWNER/OPERATOR MANUAL SPECIFICATIONS Airmotor effective dia. in. 2.5 Airinlet Material outlet 1/4 NPTF 1/4 NPTF Liquid to Air Pressure

More information

Cyclone II. Cyclone. and OPERATOR S MANUAL IMPORTANT- READ OPERATOR S MANUAL BEFORE USE.

Cyclone II. Cyclone. and OPERATOR S MANUAL IMPORTANT- READ OPERATOR S MANUAL BEFORE USE. Cyclone and Cyclone II OPERATOR S MANUAL IMPORTANT- READ OPERATOR S MANUAL BEFORE USE. 4401 Page Ave. Michigan Center, Michigan 49254 800-248-4010 www.adcocorp.com Rev. 0410 Introduction To the Cyclone

More information

Electric Diesel Pump EDP/12, EDP/24

Electric Diesel Pump EDP/12, EDP/24 INSTRUCTION MANUAL Electric Diesel Pump EDP/1, EDP/4 S1940, Rev C Congratulations on purchase of this World Class Electric Diesel Pump! Portable Diesel transfer pumps designed for everyday use in Agricultural,

More information

PVDF TURBINE HOUSING

PVDF TURBINE HOUSING Industrial Grade PVDF TURBINE HOUSING Owner s Manual Turbine shown here with Computer Electronics which are sold separately. 5252 East 36th Street North Wichita, KS USA 67220-3205 TEL: 316-686-7361 FAX:

More information

OWNER'S MANUAL SAVE THESE INSTRUCTIONS

OWNER'S MANUAL SAVE THESE INSTRUCTIONS PRO25-012 12-Volt DC OWNER'S MANUAL SAVE THESE INSTRUCTIONS PRO25-024 24-Volt DC PRO25-012AD Automatic Diesel Nozzle PRO25-024AD Automatic Diesel Nozzle PRO25-012MD Manual Diesel Nozzle PRO25-024PO Pump

More information

PARTS AND INSTALLATION MANUAL

PARTS AND INSTALLATION MANUAL PSP-3240 POLYPROPYLENE SELF-PRIMING 2 CENTRIFUGAL PUMP PARTS AND INSTALLATION MANUAL PSP-3240 Shown with GX-160 Honda CDS-JOHN BLUE COMPANY DIVISION OF ADVANCED SYSTEMS TECHNOLOGY, INC. 165 Electronics

More information

PANTHER HP SERIES OIL PUMPS 3:1 Model # Bare Pump # Flange Mount 5:1 Model # Bare Pump # Flange Mount

PANTHER HP SERIES OIL PUMPS 3:1 Model # Bare Pump # Flange Mount 5:1 Model # Bare Pump # Flange Mount SERVICE BULLETIN SB1064 Rev. O 02/09 PANTHER HP SERIES OIL PUMPS 3:1 Model #1130-015 Bare Pump #1130-017 Flange Mount 5:1 Model #1130-016 Bare Pump #1130-018 Flange Mount Thoroughly read and understand

More information

Air-Operated 5:1 Oil Pump

Air-Operated 5:1 Oil Pump Air-Operated 5:1 Oil Pump With Extension Kit - 3.7 GPM Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUC- TIONS before operating. Failure to follow the safety rules

More information

Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power

Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power Page 1 of 8 equipment and follow handling procedures per OSHA 29 CFR 1910.1030 when handling equipment after waste water source has been connected to system. WARNING: Risk of Asphyxiation. Installer(s)

More information

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-122 REV A 12/09

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-122 REV A 12/09 HAND CRANK WELDING CABLE REEL: SERIES 100WC COXREELS The technical data and images which appear in this manual are for informational purposes only. NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES

More information

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM Performance Model HP GPH of Water @ Total Feet Of Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. 25 ft. Max. Lift SUNC1200

More information

QSB (Q-Star) Electronics for QSE Electromagnetic Meter. Owner s Manual TABLE OF CONTENTS

QSB (Q-Star) Electronics for QSE Electromagnetic Meter. Owner s Manual TABLE OF CONTENTS Owner s Manual QSB (Q-Star) Electronics for QSE Electromagnetic Meter Plain Cover Plate and Pulse-Out Transmitter (QSB) Display Mount Cover Plate (to mount a Q09 Display) and Pulse-Out Transmitter (QSB)

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL PAGE: 1 of 6 INSTALLATION, OPERATION AND MAINTENANCE MANUAL ROSEDALE PRODUCTS, INC. MODEL LCO-8 125 PSIG RATED FILTER UNIT MODEL LCO-8 Table of Contents I. Installation...............................................................