FUEL MANAGEMENT SYSTEM SentryGOLD INSTALLATION MANUAL

Size: px
Start display at page:

Download "FUEL MANAGEMENT SYSTEM SentryGOLD INSTALLATION MANUAL"

Transcription

1 FUEL MANAGEMENT SYSTEM SentryGOLD INSTALLATION MANUAL TRAK SentryGOLD Installation Manual rev

2 IMPORTANT The SentryGOLD and associated equipment will be installed in close proximity to combustible fuel dispensers. For the safety of all concerned, it is essential that you read and understand the instructions in this manual before proceeding. ****** CAUTION ****** TURN OFF ALL POWER TO THE ISLAND BEFORE BEGINNING INSTALLATION. THE SENTRYGOLD SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE (NFPA NO. 70), THE AUTOMOTIVE AND MARINE SERVICE STATION CODE (NFPA NO. 30A) AND LOCAL ORDINANCES. DO NOT INSTALL THE SENTRYGOLD SYSTEM IN A LOCATION THAT DOES NOT MEET THE REQUIRED STANDARDS AS LISTED ABOVE. QUALIFIED LICENSED ELECTRICIANS ARE REQUIRED TO PERFORM ANY MODIFICATIONS OR ALTERATIONS TO THE ELECTRICAL CIRCUITS AT ANY INSTALLATION SITE ALL PARTS USED TO INSTALL THE SENTRYGOLD SYSTEM INSIDE A DISPENSER THAT ARE NOT PART OF THE INSTALLATION PACKAGE, SHALL BE SUITABLE FOR USE IN CLASS 1, GROUP D HAZARDOUS LOCATIONS. ALL INSTALLATIONS SHALL ALSO COMPLY WITH OSHA SAFETY STANDARDS. FAILURE TO COMPLY WITH THE LISTED CAUTIONS MAY RESULT IN SERIOUS PERSONAL INJURIES, PROPERTY LOSS AND/OR EQUIPMENT DAMAGE. Trak SentryGOLD Installation Manual rev ii

3 TABLE OF CONTENTS SECTION 1.0 OVERVIEW Product Description Installation Overview Site Criteria Pre-Installation Instructions. 2 SECTION 2.0 SENTRY MOUNTING Location Sentry Mounting. 4 SECTION 3.0 MOTHER BOARD INSTALLATION. 6 SECTION 4.0 FIELD WIRING Overview Connecting Power Control Card Installation Pulser Card Installation Communication Card and External Comm Cable Install. 17 SECTION 5.0 COMPACT INSTALLATION Overview Electrical Connections Inserting the Compact into the Housing 20 Trak SentryGOLD Installation Manual rev iii

4 Section 1.0 Overview The object of this document is to provide a standard for the installation of the TRAK SentryGOLD Fuel Management System (FMS). Installation of this system shall ONLY be performed by qualified service personnel. 1.1 Product Description The SentryGOLD System installation consists of three primary groups: The SentryGOLD Pedestal Dispenser Interface Communication Interface 1.2 Installation Overview The instructions contained in this manual are intended as guidelines. They will not describe all possible variations that may occur. If the person installing the SentryGOLD is not thoroughly knowledgeable in all aspects of this type installation, it is strongly recommended that assistance be requested from Trak Customer Support at (850) before proceeding. The installer will mount the SentryGOLD on, or near, fuel dispensers, connect power and control lines from the SentryGOLD mother board to the dispensers and mount and test the communication links. One SentryGOLD mother board will control up to 5 high power devices such as a pump motor, or 10 low power devices such as a dispenser solenoid valve or 30 fiber optically controlled hoses. 1.3 Site Criteria The Sentry will control virtually any dispenser on any island configuration. It may be placed in almost any environment. However, there are several environmental restrictions that must be followed for both safety and functionality: DO NOT locate the Sentry where the temperature is consistently above +130 F or below -40 F DO NOT locate the Sentry where it will put the user at risk from the local traffic. TRAK SentryGOLD Installation Manual rev

5 DO NOT locate the Sentry within 18 inches of a dispenser or within 10 feet of a natural gas dispenser. 1.4 Pre-Installation Instructions The SentryGOLD Fuel Management System will accommodate either single or dual hose dispensers. It may be installed to control either a remote or a selfcontained dispenser. Before installation, it must be determined that there is sufficient space in the dispenser junction box to install the required equipment. The SentryGOLD can control dispensers either with fiber optic controls or with direct hard wire connections. If Connecting with Fiber Optics: There must be sufficient space for the Pump Control Module (PCM) to be installed without interfering with the operation of the dispenser or the access required for maintenance or service. A. Each dispenser junction box must have one available opening, which can be used to connect the PCM. B. Open the junction box. Determine if there is sufficient space to safely make the additional connections that will be required. If the box appears to be full, have an electrician trim the existing wiring to provide the necessary space. The volume of the junction box, in cubic inches, is usually stamped on the inside. You will need approximately 10 cubic inches. If not, you can measure the length, width and depth of the box to calculate the available space. Estimate the amount of available space currently taken up by the wires in the box. This will give you an approximate value for the remaining space. For example, if a junction box that is 30 cubic inches in size is one third full, there will be 20 cubic inches remaining. C. ONLY TRAK APPROVED PULSERS AND PULSER POWER UNITS MAY BE USED AND ONLY CONNECTED TO THE VEEDERROOT MECHANICAL REGISTERS. Check to make sure that the pulser is compatible with the register and dispenser and that its wires can be safely routed to the bottom of the dispenser. The PCM can be used if, and only if all the above conditions are satisfied. If for any reason these criteria cannot be met, contact TRAK for alternate methods of installation. Trak SentryGOLD Installation Manual rev

6 If Connecting with Hard Wire: If controlling the dispener with hard wire, conduit will need to be run from each dispenser to the Fuel Sentry housing. This may already exist. If not, it will have to be run. It can be run above ground on top of the fuel island as long as it does not present a trip hazard. The use of hard wire will also require separate conduits for power and pulser circuits. Section 2.0 Sentry Mounting The first part of the installation shall be the Fuel Sentry housing. As mentioned earlier, there are many different fuel island configurations. The following example should be used as a guideline and adapted to your specific needs. The Sentry can be supplied with a riser. It is designed to be mounted at the bottom of the Sentry housing and is made from a durable plastic but also allows any conduit to be easily run through it. It also is designed to allow the Sentry to be mounted higher when required. If the users will be standing on the same level as the Sentry, the riser should be used for the Sentry to be at optimum height. If the Sentry is mounted on a raised fuel island, the Sentry housing can be mounted directly to the island surface without the riser. 2.1 Location The Sentry, as shown on the next page, is designed to be mounted within a few feet of the dispenser. As a minimum, it must be mounted no closer than 18 inches of any nozzle opening. Site conditions permitting; place the Sentry 2 to 3 feet from the dispenser. Trak SentryGOLD Installation Manual rev

7 SENTRY RISER FUEL ISLAND Conduit to dispenser The picture above shows the Sentry housing ready to be placed on the riser with a piece of conduit run from the housing, out through the riser and over to the dispenser. Multiple conduits would be required in most installations and are not represented in this example. Bear in mind that the Sentry may also have several Fiber Optic (FO) cables running from the Sentry housing to the dispensers if fiber optic controls are utilized. In many cases, existing conduit may already be installed. The Sentry may be bolted down over the existing conduit. Remember that power must be delivered to the Sentry and control cables must run from the Sentry to the dispenser. Exactly how this is accomplished is not critical, but must comply with all required codes. 2.2 Sentry Mounting Using the template located in the back of this manual, lay out the proper bolt pattern for the Sentry. As shown on the next page, the Sentry is attached to two Trak SentryGOLD Installation Manual rev

8 mounting brackets that are, in turn, attached to the concrete fuel island via four anchor bolts. Sentry Front 1. Locate the position of the Sentry. Remove the template from the back of this manual and place it on the ground. Carefully mark the centerline of each concrete anchor hole. 2. Remove the template, and drill four holes as marked, with a 3/8 inch concrete bit. Drill each hole three inches deep. Remove excess dust from each hole. 3. Remove the left and right mounting brackets, and place the brackets over the four holes as shown. Insert the four Anchor Sleeves into the four holes. Place the Anchor Washers on the Anchor Bolts, and screw them into the Anchor Sleeves. Tighten by hand (finger-tight only). 4. Place the Sentry down over the two mounting brackets, and insert and tighten the four mounting screws. Remove the four mounting screws, and carefully lift the Sentry straight up and off. Using a wrench, tighten the four anchor bolts. Be careful not to move the bracket s position. Now the Sentry may be replaced or removed, as necessary, by the four mounting screws. 5. The riser is mounted in the same manner. It is assembled on site but uses taller mounting brackets. The riser kit includes the taller mounting brackets. Trak SentryGOLD Installation Manual rev

9 Section 3.0 Mother Board Installation The mother board housing is installed in the rear of the Sentry housing via four ¼ -20 screws. The mother board housing is installed with the warning sticker at the top. The mother board housing cover is attached with 4 large thumbnuts. To remove, just unscrew the four thumbnuts and pull the cover off. When the cover is removed, the inside reveals two separate sections: 1. Low voltage on the left only low voltage wires or fiber optic cables can be placed in this side no signal wire over 24 volts is allowed. 2. High voltage on the right - only high voltage lines greater than 24 volts but less than 125VAC are allowed on this side. Fiber optic is also allowed on this side. WARNING: You must have training in the installation, service or maintenance of this equipment before working on it. Maintenance repairs must be done by authorized personnel only. Warranty work may only be performed by Trak certified technicians. Each section contains card edge connectors. Certain plug-in cards are available for each side. The cards, their function and placement are explained in Section 4.0. The low voltage sections contain a number of ten pin connectors whose function is explained in section 4.3. The high voltage section contains 4 ten pin in-line connectors whose function is explained in section 4.3. The very last card in the bottom right in the high voltage section contains a plug in transformer. This card is not field removable. It contains a 12 volt transformer that provides power to the plug in cards. Also on the right hand side is an ON/OFF switch. The proper label for the switch is located on a sticker on top of the switch. The OFF position is closest to the edge of the housing. J15 J14 J13 J12 J11 J10 J9 J8 J7 LOW VOLTAGE J1 J2 J3 HIGH VOLTAGE J5 J4 ON/OFF Trak SentryGOLD Installation Manual rev

10 J32 J4 J5 ACH1 ACLO Section 4.0 Field Wiring 4.1 Overview The Sentry requires 115VAC for operating power. The Sentry can also control (turn on and off) the power (generally 115VAC) to a dispenser solenoid valve or dispenser pump motor. The Sentry also receives pulses in from the dispenser, showing the number of gallons of product dispensed. All of these controls, power to the Sentry, pump on/off control and pulser inputs, are wired into and through the Mother Board enclosure. The following sections describe how to connect power to the Mother Board (which routes that power to the Sentry Compact), how to wire the on/off controls to the dispenser and how to wire the pulser wires from the dispenser into the pulser circuits in the Mother Board. The Sentry is capable of either direct wire control (both pump on/off and pulser) or fiber optic control (both pump on/off and pulser). This manual deals primarily with hard wire connections. 4.2 Connecting Power Power is required to operate the mother board assembly. It is designed for 115VAC only. It is connected to the power connector as shown below: 1. Connect AC power hot (115VAC) to ACH-IN 2. Connect AC neutral to ACLO-IN 3. Connect a green ground wire to GND T5B T5A K5B K5A T4A T4B K4B K4A T1B T1A ACHI2SW ACHIFSW ACLO AC2 12VACLO AC1 12VACHI ACSWLO ACSWHI GND ACLO-IN ACHI-IN ON/OFF White wire to Compact power Black wire to Compact power Ground AC Neutral AC Hot Trak SentryGOLD Installation Manual rev

11 The Mother Board also supplies power to the Compact. Those wires are connected to ACSWHI and ACSWLO as shown above. Those wires are the black and white wires that connect to the white Metro connector that is supplied with the Sentry Compact and connect to the matching black and white wire power connector on the back of the Compact. 4.3 Control Card Installation The low and high voltage sections contain multiple card edge connectors. The connectors are intended to have plug in cards inserted into them. Cards are either intended for the low voltage section OR the high voltage section. They are not interchangeable. Each card is keyed and will only fit into the appropriate section. Several slots are reserved for specific function cards. Slot J11 is reserved for the communication card. Slot J15 can be used for any low voltage card, but when communicating to Trak tank level probes, the slot is reserved for the probe communication card. With the exceptions outlined above, any low voltage card can be used in any low voltage slot, and any high voltage card can be used in any high voltage slot. In general some cards will physically fit or work better in some slots versus others, but it is left up to the installer to make that decision. Cards currently available are: High Voltage 1. High voltage slot fiber optic transmit card (controls external Pump Control Modules) 2. High voltage slot fiber optic receive card (receives pulses from Pulser Power Unit) 3. High voltage slot direct wire pump control card Low Voltage 1. Low voltage slot fiber optic transmit card (controls external Pump Control Modules) 2. Low voltage slot fiber optic receive card (receives pulses from Pulser Power Unit) 3. Low voltage slot direct wire pulser input card 4. Low voltage slot communication card (several in this series depending on the communication selected hard wire, fiber optic, radio, etc.) (slot J11) 5. Low voltage slot tank probe communication card (slot J15) Trak SentryGOLD Installation Manual rev

12 Each card is explained below. 1. High voltage slot fiber optic transmit card. This card, shown below, is designed exclusively for the high voltage section. Since fiber optics is used to and from the card, the fiber optic cable can be placed in the high voltage section. This card can be used in any high voltage slot. The card has 6 fiber optic outputs. Each output can be used to drive a single Trak Pump Control Module (PCM). The maximum range for the cable is 100 feet. The fiber optic cable is inserted directly into the appropriate fiber optic cavity. Once inserted, the FO cable is held in with friction. No other clamp is necessary. For best results, the clear Teflon covering on the cable should be removed on the last ¼ of cable before it is inserted. 2. High voltage slot fiber optic receive card. This card is designed exclusively for the high voltage section. Since fiber optics is used to and from the card, the fiber optic cable can be placed in the high voltage section. This card can be used in any high voltage slot. The card has 6 fiber optic inputs. Each input can be used to receive pulses from a single pulser power unit (PPU). The maximum range for the cable is 100 feet. The card is shown here. The fiber optic cable is inserted directly into the appropriate fiber optic cavity. Once inserted the FO cable is held in with friction. No other clamp is necessary. For best results, the clear Teflon covering on the Trak SentryGOLD Installation Manual rev

13 cable should be removed on the last ¼ of cable before it is inserted. 3. High voltage slot direct wire pump control card. This card is designed to be utilized exclusively in the high voltage section. It is intended to directly control the solenoid valve, reset mechanism or internal suction pump of the dispenser. This card does not utilize the fiber optic control system. With this card, the dispenser control wiring is brought directly to the mother board and connected to the plug in connectors J32 or J34. This card is intended to control either two low power devices (solenoid, reset mechanism, or contactor) or one high power device (suction pump of the dispenser). These devices must all be rated 115VAC. The low power device must not exceed.5 amperes (1/2 amp). The high power device must not exceed 10 amps. The installer must be certain to follow these limitations or damage to the equipment will result. 4. High voltage slot direct wire pump control card controlling low power devices. The cards are wired into the mother board as follows for low power applications: Card Slot J1 1 st low power device to be controlled J32 - K1A and K1B 2 nd low power device to be controlled- J34 - T1B and T1A A physical example of how this is wired is shown below. The same logic is used for wiring all other connections. The pump control card also has 2 jumpers on the back labeled JUMP. They consist of a piece of solid wire soldered across 2 terminals. These MUST be removed for the card to properly control 2 independent low power devices. They can be removed with a soldering iron or can be clipped with sharp pair of clippers. Card Slot J2 - Card Slot J3-3rd low power J34 K2A and K2B 4th low power J34- T2B and T2A 5th low power J34 K3A and K3B 6th low power J34- T3B and T3A Trak SentryGOLD Installation Manual rev

14 K1A K1B T2B T2A K2A K2B T3B T3A K3A K3B H12 H11 H22 H21 H32 H31 H42 H41 H52 H51 T5B T5A K5B K5A T4A T4B K4B K4A T1B T1A Card Slot J4 - Card Slot J5-7th low power J32 K4A and K4B 8th low power J32 - T4B and T4A 9th low power J32 K5A and K5B 10th low power J32 - T5B and T5A AC power ACH1 ACLO ACH1 ACLO ACH1 ACLO J3 J34 J33 J32 J2 J1 Solenoid 1 Low Power Device 1 Solenoid 2 AC power Low Power Device 2 5. High voltage slot direct wire pump control card controlling high power devices. These cards can also be utilized to control a single higher power device per card. In general, these devices would include a self-contained pumping motor. This type motor cannot exceed a ¾ horsepower motor, or damage will result to both the control card and the Mother Board. In the previous section, each pump control card could control 2 low power devices. In this section, each card can control only 1 high power device. The jumpers on the back of the card, labeled JUMP, must be intact. If they are not, the only options are to use a card with intact jumpers or to solder a jumper from across the 2 solder points for each jumper, using a short piece of solid 14 awg wire. This is accomplished by wiring the primary control lines from the pump motor to two of the terminals (J34 KIB and KIA) as shown below, It is recommended that 16awg wire be used. Trak SentryGOLD Installation Manual rev

15 These cards are wired as follows for high power applications: Slot J1 1 st high power connection J34 - K1B and K1A A physical example of how this is wired is shown below. The same logic is used for wiring all other connections. ACH1 ACLO ACH1 ACLO J3J34 J33 J2 J32 ACH1 ACLO J1 AC power P Pump Motor Card Slot J2-2nd high power connection J34 K2B and K2A Card Slot J3-3rd high power connection - J34 K3B and K3A Card Slot J4-4th high power connection J32 K4B and K4A Card Slot J5-5th high power connection J32 K5B and K5A Trak SentryGOLD Installation Manual rev

16 Pulser 1 Pulser 6 Pulser 5 Pulser 4 Pulser 3 Pulser 2 Pin 1 Pin Pulser Card Installation There are two types of pulser cards: 1) Fiber optic (shown in C2 above) and 2) Hard Wire. The fiber optic cards are designed to be used either in a low voltage slot or a high voltage slot. They are not interchangeable they will only fit into the proper voltage slot. The hard wire pulser card is designed for the low voltage slots only. Each hard wire card has 6 pulser inputs on the back of the card as shown to the right. Pin 1 is the same for each input. These are 2 pin Molex connectors, which are crimp on pins. For long term reliability, the pins should be soldered after crimping. Trak recommends 2 conductor shielded 26 awg wire with 600 VAC insulation. Two conductors are wired from each pulser input to the physical pulser that is attached at the dispenser. The pulser card is a multifunctional card. It is designed to work with many different pulsers. Many pulsers are either electronic or have an electronic output commonly called open collector. In the pulser configurations shown on page 15, the pulser card can be reconfigured to match whichever pulser configuration is required. The first schematic shows the card as it is shipped from the factory (Standard Card). The next two (PLS Configuration and CTC Configuration) show both the pulser used to connect to an electronic powered pulser and a nonpowered mechanical pulser. In the PLS configuration, the card can supply low voltage DC power to an electronic pulser circuit. This typical circuit is shown on page 16. However, if additional voltage is required, a Pulser Power Card can be utilized (supplied by Trak) that will insert into any unused low voltage mother board slot. This circuit is shown on page 17. It is not the intent of this section to fully describe all possible pulser configurations but rather to serve as a general guideline to assist in connecting to different types. Trak is always willing to provide telephone assistance when necessary. Trak SentryGOLD Installation Manual rev

17 Once a decision has been made as to the configuration necessary, the card can be modified to meet that criteria. If it is necessary to remove the diode, it can be either unsoldered or clipped off with a pair of sharp cutters. The card is shipped with jumpers on the CTC/PLS headers. To change, simply pull the jumper off, and replace in the proper spot. LOW P1 P2 P3 P4 P5 P6 PLS CTC Diodes CTC PLS Trak SentryGOLD Installation Manual rev

18 +5 1 P1 PLS CTC + 2 1K 1M 10K +5 CTC Standard Card +5 PLS 1 + P1 Pulser input signal high 2 To Pulser Power Card ground connection 1K 10K 1M PLS Configuration: Used for powered pulsers - typical Veeder Root pulser powered by Trak Pulser Power Card Pulser input signal ground 1 Remove Diode + P1 Pulser input signal high 2 1K 1M 10K +5 CTC Configuration: Used for non powered pulsers - typical Trak pulser Trak SentryGOLD Installation Manual rev

19 Described below is a typical connection to an electronic pulser that requires a limited amount of power from the Trak Hard Wire Pulser Card. This configuration also is correct for using a non-powered (dry contact closure) pulser switch typical of Trak supplied pulsers. The two wires of the pulser simply connect to pins 1 & 2 of any pulser input connector on the hardwire pulser card. How to connect Sentry Gold hardwire pulser card to Gasboy Electronic 9800 Series Dispensers +5V 1 2 U4 4 3 P1 1 Pulse 1 Red P1 Pin 2 Pin 1 1k Remove CR1 10k U3 C06425 ASSY Gasboy 9800 Pump I/F PCB Pulse 2 3 Return 4 N/C Green White Black Leave black capped in junction box P2 Pin 2 Pin 1 1k +5V Remove CR2 10k Trak Hardwire Pulser Card + Place both jumpers on 'CTC' setting Note that each pulser input connector on the pulser card is a 2 pin Molex. When viewing the card from the component side with the pins at the top, the right hand side pin is the common return pin. The diodes can be removed by desoldering or clipping. Sometimes a dispenser pulser circuit requires more than 5 volts to operate as shown above. In these cases Trak supplies a Pulser Power Card. This is simply a card that plugs into any low voltage slot on the mother board and supplies 12VDC out each of the 2 pin Molex connectors. It is configured as shown below. The resistor shown as to be determined has to be sized according to the dispenser pulser manufacturer, and the actual placement in the circuit may vary depending on the manufacturer recommendations. Trak SentryGOLD Installation Manual rev

20 How to connect Sentry Gold hardwire pulser card to a pulser that requires extended voltage to operate Resistor to be determined by dispenser requirements P1 Pin 2 Pin 1 Trak Pulser Power Card +12 VDC GND 1 2 U3 4 3 Pulser Power Return P1 Pin 2 Pin 1 1k 10k - + Dispenser Pulser +5V Trak Hardwire Pulser Card Place both jumpers on 'PLS' setting Note that each pulser input connector on the pulser card is a 2 pin Molex. When viewing the card from the component side with the pins at the top, the right hand side pin is the common return pin. 4.5 Communication Card and External Comm Cable Installation Slot J11 is reserved for all communication cards. There are multiple types of communication cards available: Hard wire current loop Fiber Optic Radio 1 watt WiFi a/g Depending on the type card selected, various other connectors will be attached to connection points on the mother board in the middle of the low voltage section. As a minimum, the Compact has two connectors that must be attached to the mother board. The wires should be fed into the mother board housing through the rectangular hole in the left side. Trak SentryGOLD Installation Manual rev

21 MASTER ADR >15 J24 J22 J24 J37 J36 1. The main external communication cable from the Compact Reader connector, labeled RS-232 on the wire itself, is a red/ black/ brown cable combination that has a 3 pin Molex female on the end, with a 3 pin Metro connector in the middle. It plugs into the 3 pin connector labeled SBC232 shown below. There are two 3 pin connectors right next to each other, and either one is fine. They are also labeled J36 and J The main internal communication cable from the Compact Comm connector labeled 485 on the wire itself is a green/ white/ blue cable combination that has a 4 pin Molex female on the end. It plugs into the 4 pin connector labeled MASTER ADR>15 shown below. There are two 4 pin connectors right next to each other, and either one is fine. They are also labeled J22 and J24. J13 J12 LOW VOLTAGE SBC232 LOCAL-HW J11 J10 Card slot J11 is reserved for the communication cards. There are several items that require attention, depending on the communication card inserted. Trak SentryGOLD Installation Manual rev

22 1. Hard Wire Current Loop - This card converts the serial data from the Compact into long distance capability, referred to as current loop. This circuit is a 4 wire circuit (2 twisted pair) of 20 to 24 awg shielded wire. It is normally capable of transmitting data reliably to 2,000 feet. The wire at the Compact end is terminated into a 4 pin Molex plug. This plugs into the mating 4 pin connector labeled above as LOCAL-HW or J Both radio cards and the FO card utilize connectors on the cards themselves and no other connectors are attached to the mother board. The radio card utilizes either an internal connector connected directly to an internal antenna or is connected to an adapter cable that allows the antenna to be mounted externally on top of the Sentry housing. Section 5.0 Compact Installation 5.1 Overview Final installation is accomplished with the insertion of the Compact into the Sentry housing. Regardless of the options selected, all Compacts will fit into any housing. The Compact simply has to have several electrical connectors snapped into place, then has to be inserted into the housing and locked in place. 5.2 Electrical Connections The Compact has 3 connectors on the rear panel. They are: 1. Reader wiring to key reader (if part of system) and main external communication wiring cable 2. Power wiring to main power (115VAC) and wiring to speaker on speaker panel 3. Comm wiring to main internal communication cable and wiring to the card reader (if part of the system) on the speaker panel These must be plugged into the back of the Compact. For the Reader & Power Connectors: Rotate collar counter clockwise to release; pull out of connector. When replacing the connector it is very important to line up the connectors properly. Line up the dots located on the base and collar of the connector. Excessive pressure is not required. If the connector is lined up properly, it will pop in with minimal effort. Once a connector is plugged in, rotate the collar clockwise to lock it in place. Trak SentryGOLD Installation Manual rev

23 For the Comm Connector: The Comm Connector is different from the Reader and Power. It does not have a collar. To plug in the connector, simply line up the dots, and push into mating connector. It should click and lock into place. 5.3 Inserting the Compact into the Housing The Compact is inserted into the housing by tilting the top of the Sentry Compact slightly towards the housing as shown. The groove in the top of the Compact will fit into the metal top of the housing. a. Make sure to tuck all wires into the housing, being careful not to pinch any wires. b. Line the groove along the top of the Sentry Head with the top edge of the opening. c. Push the Sentry Head upwards as far as it will go. d. Push the bottom end toward the housing. e. Make sure edges are flush and no wires are pinched between the housing and the Sentry head. f. Slide Sentry Head downwards until it comes to rest on the bottom edge of the opening. g. Lock the Sentry Head in place with the housing key. Trak SentryGOLD Installation Manual rev

Sentry VI INSTALLATION MANUAL

Sentry VI INSTALLATION MANUAL FUEL MANAGEMENT SYSTEM Sentry VI INSTALLATION MANUAL Trak Engineering, Inc. 2901 Crescent Drive Tallahassee, FL 32301-3535 Phone:(850)878-4585 FAX:(850)656-8265 Email: support@trakeng.com Web Site: www.trakeng.com

More information

LCD Annunciator Installation Instructions

LCD Annunciator Installation Instructions 4603-9101 LCD Annunciator Installation Instructions Cautions and Warnings DO NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED. Upon unpacking your Simplex product, inspect the contents of the carton

More information

L5000 Plus. Installation & Setup Guide

L5000 Plus. Installation & Setup Guide L5000 Plus Page 1 of 16 JDE1945 IssB s1 May 2009 Contents Description Page Safety... 3 Installation Standards 4 Specification. 4 Installation Procedure Pump Box. 6 Auxiliary Pump Boxes... 7 Connecting

More information

Mizer Single Pump and Starter Box

Mizer Single Pump and Starter Box Mizer Single Pump and Starter Box Table of Contents Line Diagram... 2 Overview... 3 Booster Pump Specifications... 3 Water... 3 Electrical... 3 Models... 3 Mounting... 4 Electrical... 6 Motor Rotation...

More information

INSTALLATION MANUAL. Melink Corporation (513) Revision

INSTALLATION MANUAL. Melink Corporation (513) Revision INSTALLATION MANUAL Revision 130711 Table of Contents Step Installation Contractor Page 1 Install System Controller Electrical 4 2 Install Variable Frequency Drive Electrical 6 3 Install Touchpad Mechanical

More information

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH IS NOT FOR "DO-IT-YOURSELF" INSTALLATION. It must be installed by

More information

Instruction Bulletin. Jockey Pump Controller

Instruction Bulletin. Jockey Pump Controller Instruction Bulletin Jockey Pump Controller Installation Start Up Service This instruction bulletin is a guide for personnel involved with maintenance, engineering and approval of Fire Pump equipment and

More information

LP-2500/2600. Installation and Setup Guide. Lighting Control Panels. Revision 3.1 July 1999

LP-2500/2600. Installation and Setup Guide. Lighting Control Panels. Revision 3.1 July 1999 /2600 Lighting Control Panels Installation and Setup Guide Revision 3. July 999 Phone:770-429-3043 http://www.triateklighting.com sales@triateklighting.com Installation Guide /2600 Lighting Panels Table

More information

Upgrade v3 to v3.2. SeeMeCNC Guides. Upgrade v3 to v3.2. Rostock Max v3 Uprgade to v3.2. Written By: SeeMeCNC seemecnc.dozuki.

Upgrade v3 to v3.2. SeeMeCNC Guides. Upgrade v3 to v3.2. Rostock Max v3 Uprgade to v3.2. Written By: SeeMeCNC seemecnc.dozuki. SeeMeCNC Guides Upgrade v3 to v3.2 Rostock Max v3 Uprgade to v3.2 Written By: SeeMeCNC 2018 seemecnc.dozuki.com/ Page 1 of 34 INTRODUCTION This guide is intended to Upgrade a Rostock Max v3 to a Rostock

More information

Validator and Control Board Update Instructions for BC1

Validator and Control Board Update Instructions for BC1 Validator and Control Board Update Instructions for BC1 Installation Overview The update kit for the Rowe BC1 enables the changer to interface with a Mars AE/VN 120-volt validator. The validator determines

More information

SentryGOLD Compact. for Bennett Electronic Dispenser INSTALLATION MANUAL. Fuel Management System

SentryGOLD Compact. for Bennett Electronic Dispenser INSTALLATION MANUAL. Fuel Management System Fuel Management System SentryGOLD Compact for Bennett Electronic Dispenser INSTALLATION MANUAL 2901 Crescent Drive Tallahassee, FL 32301 (850) 878-4585 office (850) 656-8265 fax www.trakeng.com support@trakeng.com

More information

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY 00 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) Track Assembly (0-) / Replacement

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

2904 Power Supply Installation Instructions I-EA00041

2904 Power Supply Installation Instructions I-EA00041 FEATURES Controls an opening with electrified locking device and automatic door operator Separate inputs for activation switch on entry and exit sides of opening Separate 24 VDC outputs for fail safe and

More information

Sentinel Field Satellite Controller

Sentinel Field Satellite Controller WARNING HIGH VOLTAGE 115V M AP Sentinel Field Satellite Controller Installation Instructions Important: For your protection and the safety of the product user, please comply with all Caution and Warning

More information

TERMINATOR User Manual

TERMINATOR User Manual TERMINATOR User Manual TERMINATOR User Manual Table of Contents Section Page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 Introduction Safety Precautions Features and Benefits Overview of the

More information

A.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual

A.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual Touch-Plate Lighting Controls ACES 3 & 6 Module System Manual A.C.E.S. Series ACES 3 & 6 MODULE PANELS System Manual Touch-Plate Lighting Controls 1830 Wayne Trace Fort Wayne, IN 46803 Phone: 260-424-4323

More information

Tunnel Control Stations Installation Instructions

Tunnel Control Stations Installation Instructions A product of DRB Systems Tunnel Control Stations Installation Instructions Copyright 2014 by DRB Systems. All rights reserved. All DRB Systems product names are trademarks or registered trademarks of DRB

More information

Trak Engineering, Inc CARWASH UNIT MANUAL!!! " ###$%&$' ())*%&$'

Trak Engineering, Inc CARWASH UNIT MANUAL!!!  ###$%&$' ())*%&$' CARWASH UNIT MANUAL!!! " ###$%&$' ())*%&$' 1 Table of Contents General Overview. 3 Technical Specification / Drawings. 6 Installation Procedures. 16 User Procedure.. 25 Operator / Setup Procedure. 31!"

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

3143 Production Drive Fairfeild, Ohio Model HA Installation and Service Manual

3143 Production Drive Fairfeild, Ohio Model HA Installation and Service Manual 3143 Production Drive Fairfeild, Ohio 45014 513-874-3733 Model HA-1000 Installation and Service Manual 3143 Production Drive Fairfeild, Ohio 45014 513-874-3733 Model HA-1000 Installation and Service Manual

More information

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION MODEL: PS600 HZ: 60 A model ps600 installation and service manual for federal model ps600 FEDERAL SIGNAL CORPORATION POWER SUPPLY VOLTS: SERIES: 120VAC FEDERAL SIGNAL CORPORATION UNIVERSITY PARK, IL. U.S.A.

More information

MAPNET II Transceiver Installation Instructions

MAPNET II Transceiver Installation Instructions MAPNET II Transceiver Installation Instructions Introduction This publication describes the installation procedure for the following versions of the MAPNET II Transceiver card. 4120/4100-0110 MAPNET II

More information

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER INSTALLATION INSTRUCTIONS WARNING: The Model 8682 Adaptive Offset Controller must be wired to 24 VAC only. Wiring the unit to 110 VAC will cause serious unit

More information

Installation Instructions Studio Makeup Station

Installation Instructions Studio Makeup Station Installation Instructions Studio Makeup Station 30" and 36" Models 5-light 30" Studio Makeup Station 8-light 30" Studio Makeup Station 6-light 36" Studio Makeup Station 9-light 36" Studio Makeup Station

More information

The full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at

The full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at Installation Manual INTRODUCTION The full WeatherTRAK Flow Installation and Maintenance Manual is available online at www.weathertrak.com General Description A WeatherTRAK Flow combines a hydraulic master

More information

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R THE RELIANCE Fast/Tran IS NOT FOR "DO-IT-YOURSELF" INSTALLATION. It must be installed by a qualified electrician thoroughly familiar with all

More information

SX-16 Nightsun Searchlight Safety and Service Bulletin # SL

SX-16 Nightsun Searchlight Safety and Service Bulletin # SL SX-16 Nightsun Searchlight Safety and Service Bulletin # SL0600-01 Issued Date: 06/22/00 Amended Date: 01/13/2010 WARNING: TO AVOID A POTENTIALLY DANGEROUS SITUATION WHICH COULD CAUSE PROPERTY DAMAGE AND

More information

VHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm with Slide-In Mounting Plate

VHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm with Slide-In Mounting Plate 3875 Cypress Drive Petaluma, CA 94954 800.228.2555 +1.707.773.1100 Fax 707.773.1180 www.gcx.com VHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm with Slide-In Mounting Plate (Refer to qualified

More information

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING CAUTION 80-957-00-00 (08-0) Series 570 Door Openings 85 to 0 or to 80 Adjustable Arm and Slide Track Application Maximum Hinge Side Frame Reveal to /8 (mm) Hinge (Pull) Side of Door Installation 5700 LEO

More information

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI II 1400-6 ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI ACSI 1426-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1092, REV. C INSTALLATION For C-UL Listed applications,

More information

Demand Switch NEFA20 Plus. Installation Guide. Please read this entire guide before beginning the installation!

Demand Switch NEFA20 Plus. Installation Guide. Please read this entire guide before beginning the installation! Demand Switch NEFA20 Plus Installation Guide Please read this entire guide before beginning the installation! Supplied Parts Protective Covers DIN Mounting Rail NEFA20 Plus Mounting Rail Spacer Warning

More information

Table of Contents. 1.0 INFORMATION 1.1 Introduction. 1.2 Product Information. 2.0 INSTALLATION 2.1 Pre-Installation. 2.2 Component Installation

Table of Contents. 1.0 INFORMATION 1.1 Introduction. 1.2 Product Information. 2.0 INSTALLATION 2.1 Pre-Installation. 2.2 Component Installation Contents Table of Contents 1.0 INFORMATION 1.1 Introduction 1.1.1 About This Manual 1.1.2 Helpful Hints and Warnings 1.1.3 Service and Product Support 1.2 Product Information 1.2.1 System Components 2.0

More information

IMPORTANT! READ BEFORE INSTALLING!

IMPORTANT! READ BEFORE INSTALLING! 1360 Redwood Way, Suite A Petaluma, CA. 94954 TEL: (707) 763-7799 Toll free in the USA (800) 767-9543 FAX (707) 763-2631 www.xandexsemi.com EMAIL: info@xandex.com Instructions for Xandex Pneumatic Controller

More information

ACSI MODEL POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-9 ACSI MODEL 1400-6100 POWER SUPPLY INSTALLATION INSTRUCTIONS Features: Used exclusively with the ACSI Series 6100 Communicating Bath Door (Common Bath) System Two separate and identical rows of

More information

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48. support@i2systems.com www.i2systems.com Electrical Specifications PARAMETER Input Power VALUE 8 Watts* / Ft Input Voltage 120-277V AC, 50/60 Hz Max. Fixture Run Length LED Color (CCT) 8 Watts: 120VAC:

More information

lkm7001 key override module Installation Instructions Converting The LKM7000 to The LKM7003

lkm7001 key override module Installation Instructions Converting The LKM7000 to The LKM7003 lkm7001 Instructions Converting The LKM7000 to The LKM7003 key override module In A Single Motion, We ll Change The Way You Think About Security Read Instructions thoroughly prior to installation Base

More information

Ground Mount / Piping / Electrical Quick Reference ECS Membrane Processor: PMC and ISD

Ground Mount / Piping / Electrical Quick Reference ECS Membrane Processor: PMC and ISD Ground Mount / Piping / Electrical Quick Reference ECS Membrane Processor: PMC and ISD Part: VST ECS-CS3-310 Three Phase VST-ECS-CS3-110 Single Phase Executive Orders: VR-203 VR-204 Version: 1.1 NOTE:

More information

5. Contractor Information 3M Model 2300 Series System Layout Checklist

5. Contractor Information 3M Model 2300 Series System Layout Checklist 5. Contractor Information 3M Model 2300 Series System Layout Checklist This checklist contains the information necessary to provide the environment required to successfully install your new Model 2300

More information

INSTALLATION MANUAL MODEL #100947, AMP MODEL #100949, AMP RELIANCE CONTROLS ARL SERIES AUTOMATIC TRANSFER SWITCH

INSTALLATION MANUAL MODEL #100947, AMP MODEL #100949, AMP RELIANCE CONTROLS ARL SERIES AUTOMATIC TRANSFER SWITCH INSTALLATION MANUAL MODEL #100947, 100950 50 AMP MODEL #100949, 100952 100 AMP RELIANCE CONTROLS ARL SERIES AUTOMATIC TRANSFER SWITCH REGISTER YOUR PRODUCT ONLINE at championpowerequipment.com or visit

More information

AMPLIFIER A OR B SELECTOR

AMPLIFIER A OR B SELECTOR M O D E L ABA-1D ABA-1D AMPLIFIER A OR B SELECTOR NILES INSTALLATION & OPERATION GUIDE ABA-1D Speaker/Amplifier Selector S P E A K E R / A M P L I F I E R S E L E C T O R TABLE OF CONTENTS Introduction

More information

(Refer to qualified personnel)

(Refer to qualified personnel) 3875 Cypress Drive Petaluma, CA 94954 800.228.2555 +1.707.773.1100 Fax 707.773.1180 www.gcx.com Installation Guide VHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm (Slide-Above-Arm Configuration)

More information

30A SMART ENERGY MANAGEMENT SYSTEM TM

30A SMART ENERGY MANAGEMENT SYSTEM TM 30 Amp EMS Display Panel P/N 00-00903-030 (Black) 30 Amp EMS Distribution Panel P/N 00-0091-000 CAUTION The 30A SMART EMS is a centralized power switching, fusing, and distribution center. Power from the

More information

SPACESAVER EC-300 A ELECTRICS

SPACESAVER EC-300 A ELECTRICS INSTALLATION INSTRUCTIONS SPACESAVER EC-300 A ELECTRICS SECTION I TOP MOUNTED ELECTRICS SECTION II FACE PANEL MOUNTED ELECTRICS SECTION III ZFS INSTALLATION INSTRUCTIONS This symbol indicates a connection

More information

HD 7700 Setup & Operator Manual

HD 7700 Setup & Operator Manual HD 7700 Setup & Operator Manual Issue 1 December, 01 Performance Design Inc. The Heavy Duty Ultima (HD 7700) electric punch has been designed to punch most any job that may pass through your bindery or

More information

Service Lev. Parts - - KEA KIT, WIRE HARNESS 03-CR-TIE4, INTAKE SIDE STARTER 1 A 1 A

Service Lev. Parts - - KEA KIT, WIRE HARNESS 03-CR-TIE4, INTAKE SIDE STARTER 1 A 1 A Item Assy. Service Part No. Description Quantity Lev. Parts Remarks - - KEA08-65100 KIT, WIRE HARNESS 03-CR-TIE4, INTAKE SIDE STARTER 1 A 1 -- KEA08-65100-INS WIRE HARNESS KIT INSTRUCTIONS 1 A 2 -- KEA08-65150

More information

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH

More information

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH

More information

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-10 ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS Features: Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit Protection Standby Battery

More information

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-8 Features: ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS Filtered/Regulated 24 Volts DC Up to Full 2 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit

More information

Wireless Remote System RC-12v & 24v Standard RF Remote Control System INSTALLATION MANUAL AND OWNERS GUIDE Table of Contents:

Wireless Remote System RC-12v & 24v Standard RF Remote Control System INSTALLATION MANUAL AND OWNERS GUIDE Table of Contents: Wireless Remote System RC-12v & 24v Standard RF Remote Control System INSTALLATION MANUAL AND OWNERS GUIDE Table of Contents: Page: 1 Important Safety Instructions/Overview. Pages: 2 Quick Reference Specifications.

More information

MODEL D-SBG Single Arm Barrier Gate Operator

MODEL D-SBG Single Arm Barrier Gate Operator INSTALLATION AND OWNER S MANUAL MODEL D-SBG Single Arm Barrier Gate Operator UL 325 and UL 991 Listed WITH NITRO BOARD (SEE SUPPLEMENTAL MANUAL) Serial #: Date Installed: Your Dealer: READ THIS MANUAL

More information

( Versions Available)

( Versions Available) STYLE 494 ELECTRIC LADDER PIPE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS ( Versions Available) The following is intended to provide the basic instructions for installation, operating and maintenance

More information

Installation Instructions

Installation Instructions Installation Instructions MX3635-01 Rev. E Models HydraSwing 40s HydraSwing 40F 4,000 lb (1,814 kg) 10-15 seconds HydraSwing 40 4,000 lb (1,814 kg) 15-20 seconds HydraSwing 40 Twin 4,000 lb (1,814 kg)/leaf

More information

5600 Series Power Operator Installation and Instruction Manual

5600 Series Power Operator Installation and Instruction Manual 5600 Series Power Operator Installation and Instruction Manual 80-956-000-00 (08-) 5 ASSA ABLOY 6 Item No. Description Motor (5600M) Cover (5600COV) Control Inverter (5600IN) Power Supply VDC (5600PS)

More information

TABLE OF CONTENTS SPECIFICATIONS 3 INSTALLATION 4. Direct Mount 4. Ducted Installations 5. Installing Plenum 5. Machine Mount Stand 5.

TABLE OF CONTENTS SPECIFICATIONS 3 INSTALLATION 4. Direct Mount 4. Ducted Installations 5. Installing Plenum 5. Machine Mount Stand 5. TABLE OF CONTENTS PAGE SPECIFICATIONS 3 INSTALLATION 4 Direct Mount 4 Ducted Installations 5 Installing Plenum 5 Machine Mount Stand 5 Ceiling Mount 6 Pedestal Stand 7 Drain Installation 7 Electrical 8

More information

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C C Mobile Communications 13 AMPERE POWER SUPPLY 19A704647P1-P3 CAUTION THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALI- FIED PERSONNEL ONLY. TO AVOID ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER

More information

VHM-P (Non-Locking) Variable Height Arm with VESA Mounting Plate for 75 x 75mm or 100 x 100mm applications

VHM-P (Non-Locking) Variable Height Arm with VESA Mounting Plate for 75 x 75mm or 100 x 100mm applications 3875 Cypress Drive Petaluma, CA 94954 800.228.2555 +1.707.773.1100 Fax 707.773.1180 www.gcx.com VHM-P (Non-Locking) Variable Height Arm with VESA Mounting Plate for 75 x 75mm or 100 x 100mm applications

More information

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING CAUTION 80-957-00-00 (08-0) Series 570 Openings 85 to 0 or to 70 Double Lever Arm Application for Frame Reveals (76) to 7 (78mm)* Stop (Push) Side of Installation 5700 LEO Operator Installation Instructions

More information

Safe-T-element Installation Instructions

Safe-T-element Installation Instructions Safe-T-element Installation Instructions For: PTI STEZA (2x2 Burner Configuration) & PTI STEZB (3x1 Burner Configuration) Revision K (May. 3 2012) TABLE OF CONTENTS 1. PREPARATION... 3 1.1 General Safety

More information

USB Charge Port Installation Instructions

USB Charge Port Installation Instructions USB Charge Port Installation Instructions Lifetime Technical Support support@logolites.com 770-476-7322 www.logolites.com Manual 100-0014C Thank you for purchasing a Logo Lites USB Charge Port! USB Charge

More information

Connector Systems Inc. SS-20 MACHINE MANUAL

Connector Systems Inc. SS-20 MACHINE MANUAL Connector Systems Inc. SS-20 MACHINE MANUAL INTRODUCTION Your SS-20 machine comes to you fully equipped and set up to terminate the style of plug you have requested. Our SS-20N will accommodate those

More information

Instruction Manual for the. E-SL 450 Series

Instruction Manual for the. E-SL 450 Series Instruction Manual for the E-SL 450 Series Estate Slide Summary of Functions The Estate Slide is only to be used for vehicular Slide gates in a Class I setting. Class I: A vehicular gate opener (or system)

More information

Digital/Analog Amplifiers Installation Instructions

Digital/Analog Amplifiers Installation Instructions Digital/Analog Amplifiers Installation Instructions Introduction This publication describes the installation procedure for the 4100U and 4100ES Fire Alarm Control Panels (FACP) family of digital and analog

More information

PowerOhm Installation Manual for LG ATV Series Braking Modules

PowerOhm Installation Manual for LG ATV Series Braking Modules PowerOhm Installation Manual for LG ATV Series Braking Modules IMPORTANT: These instructions should be read thoroughly before installation. All warnings and precautions should be observed for both personal

More information

Stay-IN-Play with Panic Stop Braking

Stay-IN-Play with Panic Stop Braking INSTALLATION INSTRUCTIONS TOWED VEHICLE BRAKING SYSTEM Stay-IN-Play with Panic Stop Braking SMI Manufacturing, Inc. P.O. Box 14040 Evansville, IN 47728 1-800-893-3763 www.smibrake.com SIP0906 Model SIP0603

More information

12v LED In Rail Lighting Installation Guide

12v LED In Rail Lighting Installation Guide 12v LED In Rail Lighting FairwayRailing.com 12v LED Connector Box wire From Transformer To next 12v LED Connector Box wire 1a. Install Transformer 1b. Run Wire 2. Install Connector Box 3. Wire Connector

More information

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY 0 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) / Replacement Motor Key (00KEY) Rod

More information

INSTALLATION M ANUAL

INSTALLATION M ANUAL INSTALLATION MANUAL Table of Contents UL Listings Installing the Warning Sign / Precautions Methods of Installation / Compact Installation Mounting the Secondary Entrapment / Welding Gate Arn Mounting

More information

EV-2051-M Electric Motor. Operation and Maintenance Manual

EV-2051-M Electric Motor. Operation and Maintenance Manual EV-2051-M Electric Motor Operation and Maintenance Manual Table of Contents Safety... 3 General...3 Safety Notices...6 Cautions, Warnings and Dangers...7 Cautions...8 Warnings...11 Dangers...13 Important

More information

ChargePoint Gateway Installation Instructions

ChargePoint Gateway Installation Instructions ChargePoint Gateway Installation Instructions You must be a licensed electrician and complete online training (http://chargepointuniversity.netexam.com/) to become a ChargePoint Certified Installer, and

More information

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit Instruction Sheet 10-2004 Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 PURPOSE OF KIT A CCM-T is used to monitor and control an automatic transfer switch.

More information

Installation Instructions: ACCENT SYSTEM

Installation Instructions: ACCENT SYSTEM Installation Instructions: ACCENT SYSTEM READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS WILL VOID YOUR WARRANTY! INSTALLATION TIPS Read this entire

More information

AGCO América do Sul (Factory Install) Installation Manual SP01

AGCO América do Sul (Factory Install) Installation Manual SP01 SP01 AGCO América do Sul (Factory Install) Installation Manual Printed in Canada Copyright 2010 by NORAC Systems International Inc. Reorder P/N: UC5-BC-SP01-INST Rev G (AGCO Brazil Factory Install) NOTICE:

More information

PRO IV LIQUID DETERGENT & LIQUID RINSE DISPENSER INSTALLATION INSTRUCTIONS REVISION #5

PRO IV LIQUID DETERGENT & LIQUID RINSE DISPENSER INSTALLATION INSTRUCTIONS REVISION #5 PRO IV LIQUID DETERGENT & LIQUID RINSE DISPENSER INSTALLATION INSTRUCTIONS REVISION #5 STEP #1. MOUNTING 1. Choose a location where the unit is visible to the machine operator. 2. Locate the unit out of

More information

Electric Vehicle Charging Station

Electric Vehicle Charging Station EVoReel Electric Vehicle Charging Station INSTALLATION GUIDE AND USER MANUAL Model: Dual Output Pedestal Mount 30A EVoReel EVSE Model Numbers: With Basic EVSE: EV072-400-002A; With Intelligent ievse: EV072-410-002A;

More information

SmartBob AO. BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE

SmartBob AO. BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE READ CAREFULLY 925-0312 Rev B TABLE OF

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Universal Air Series!! NOTE!! Covers the following model: 6000 Series 85-0100B-AZ Rev 0 5/07 To ensure that the system is installed properly, provide your electrician with these

More information

3875 Cypress Drive Petaluma, CA Fax

3875 Cypress Drive Petaluma, CA Fax 3875 Cypress Drive Petaluma, CA 94954 800.228.2555 +1.707.773.1100 Fax 707.773.1180 www.gcx.com VHM-P (Non-Locking) Variable Height Arm with Fixed Angle Front End for Flat Panel / Keyboard Bracket (L Brackets

More information

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL INSTALLATION INSTRUCTIONS AND OPERATION MANUAL UL325-2010 Compliant Commercial and Industrial Door Operator Logic Control Continuous Duty IMPORTANT INSTALLATION INSTRUCTIONS WARNING To reduce the risk

More information

Service Manual. Model Number: DF2426GB DF2426SS DF2550 DF2562. UL Part Number to 500

Service Manual. Model Number: DF2426GB DF2426SS DF2550 DF2562. UL Part Number to 500 Service Manual Model Number: DF2426GB DF2426SS DF2550 DF2562 UL Part Number 6905050100 to 500 IMPORTANT SAFETY INFORMATION: Always read this manual first before attempting to service this fireplace. For

More information

WPS-2800 SERIES HIGH POWER VOICE & SIREN SYSTEM

WPS-2800 SERIES HIGH POWER VOICE & SIREN SYSTEM ENGINEERING COMPANY INC. Route 45, Winthrop Road, Chester, Connecticut 0642 Phone: (800) 63SIREN Phone: (860) 526-9504 Fax: (860) 526-4078 Internet: www.whelen.com Sales e-mail: iowsales@whelen.com Customer

More information

Combined Ventilation Controller RVWS-T-224HA

Combined Ventilation Controller RVWS-T-224HA Combined Ventilation Controller RVWS-T-224HA 8-stage Control for Power/Natural Applications 2 variable speed stages, 2 curtain winch stages, 2 fixed speed ventilation stages, 1 thermo/mister cycle stage

More information

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS PowerMaster TABLE OF CONTENTS MODEL MBG MEDIUM DUTY BARRIER GATE OPERATOR Important Safety Information...... 3 System Designer Safety Instructions.......4 Installer Safety Instructions....... 5 Installation

More information

INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE

INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE ENGLISH ESPAÑOL INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE Please read these instructions thoroughly before installing and operating the range. LDE3019ST LDE3017ST LDE3017SB LDE3017SW LDE3015ST LDE3015SB

More information

E.S.P. Embedded Sensing Probes for Motor Brushes

E.S.P. Embedded Sensing Probes for Motor Brushes E.S.P. Embedded Sensing Probes for Motor Brushes 2/13 Installation & Operating Manual MN609 Any trademarks used in this manual are the property of their respective owners. Important: Be sure to check www.baldor.com

More information

Installation Instructions: HYPERION R-Lite SYSTEM

Installation Instructions: HYPERION R-Lite SYSTEM Installation Instructions: HYPERION R-Lite SYSTEM READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS WILL VOID YOUR WARRANTY! INSTALLATION TIPS Read

More information

Operating Instructions Type MPT 53

Operating Instructions  Type MPT 53 Operating Instructions www.turnstiles.us Type MPT 53 Contents 1. Delivery... 2 2. Safety...3-4 3 Description and operation... 5 4. Technical Data 6 5. oundation...6-9 6. Assembly and installation...10-13

More information

Service Lev. Parts - - KEA KIT, WIRE HARNESS 03-CRS, EXHAUST SIDE STARTER 1 A 1 -- KEA INS WIRE HARNESS KIT INSTRUCTIONS

Service Lev. Parts - - KEA KIT, WIRE HARNESS 03-CRS, EXHAUST SIDE STARTER 1 A 1 -- KEA INS WIRE HARNESS KIT INSTRUCTIONS Item Assy. Service Part No. Description Quantity Lev. Parts Remarks - - KEA07-65000 KIT, WIRE HARNESS 03-CRS, EXHAUST SIDE STARTER 1 A 1 -- KEA07-65004-INS WIRE HARNESS KIT INSTRUCTIONS 1 A 2 -- KEA07-65050

More information

At-FST Series I N S TA L L AT I O N A N D O P E R AT I N G I N S T R U C T I O N S W W W. A I G I S M E C H. C O M

At-FST Series I N S TA L L AT I O N A N D O P E R AT I N G I N S T R U C T I O N S W W W. A I G I S M E C H. C O M FULL HEIGHT GALVANIZED STEEL TURNSTILE SINGLE UNIT 3 60 At-FST Series AT-FST SERIES I N S TA L L AT I O N A N D O P E R AT I N G I N S T R U C T I O N S W W W. A I G I S M E C H. C O M SAFETY PRECAUTIONS

More information

Installation Manual. CS9300 Professional Series Landscape Lighting System

Installation Manual. CS9300 Professional Series Landscape Lighting System Installation Manual CS9300 Professional Series Landscape Lighting System CS9300 Professional Series Landscape Lighting System pg. 1 READ THESE INSTRUCTIONS ENTIRELY BEFORE BEGINNING INSTALLATION! Congratulations

More information

Generator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit

Generator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit Instruction Sheet 10 2004 Generator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit 541 0810 GENERAL INFORMATION This kit contains one Control Communications Module (CCM-G) with

More information

Installation Instructions for LED Timing Light

Installation Instructions for LED Timing Light Daytona Sensors LLC Engine Controls and Instrumentation Systems Installation Instructions for CAUTION: CAREFULLY READ INSTRUCTIONS BEFORE PROCEEDING OVERVIEW The P/N 120001 includes a versatile controller

More information

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017 FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017 Maxi-Tronic, Inc. 417 Wards Corner Road Loveland, OH 45140 513.398.2500 800.659.8250 FAX: 513.398.2536 info@maxitronic.com

More information

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G)

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G) Part A, Section 3 Model This section covers the following unit configurations: 3100V 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G) Manifold Control 4-Port (A) 6-Port (B) Vista Temperature (TC) A 3-0

More information

PROCUREMENT SPECIFICATIONS DELTA MODEL DSC 1500 PORTABLE BEAM - CRASH CERTIFIED BARRIER SYSTEM

PROCUREMENT SPECIFICATIONS DELTA MODEL DSC 1500 PORTABLE BEAM - CRASH CERTIFIED BARRIER SYSTEM PROCUREMENT SPECIFICATIONS DELTA MODEL DSC 1500 PORTABLE BEAM - CRASH CERTIFIED BARRIER SYSTEM Copyright 2019 Delta Scientific Corporation Page 1 of 8 SYNOPSIS This Procurement Specification defines a

More information

Digital II Pressure Control Module. Model IN64235 August Installation Instructions. Applicable addition manuals:

Digital II Pressure Control Module. Model IN64235 August Installation Instructions. Applicable addition manuals: Aerospace Group Conveyance Systems Division Carter Brand Ground Fueling Equipment IN64235 August 2009 Applicable addition manuals: IN64101 IN64108 IN64102 IN64802 SU64235 Installation Instructions Digital

More information

Service Quantity Lev. 2 A FOR P-CLAMP

Service Quantity Lev. 2 A FOR P-CLAMP Item Assy. Service Part No. Description Quantity Lev. Parts Remarks - - KEA06-65000 KIT, WIRE HARNESS (07-CRS) 1 A - -- KEA06-65004-INS WIRE HARNESS KIT INSTRUCTIONS 1 A 1 -- KEA06-65050 WIRE HARNESS,

More information

MONORAIL KITS INSTALLATION INSTRUCTIONS PENDANTS

MONORAIL KITS INSTALLATION INSTRUCTIONS PENDANTS MONORAIL KITS PENDANTS JESCO Lighting Group is a UL and ETL listed company Copyright 2011 JESCO Lighting Group. All rights reserved. IMPORTANT SAFETY INSTRUCTIONS Be sure to read and unsderstand the following

More information

Sectional And Tilting Door Opener

Sectional And Tilting Door Opener Sectional And Tilting Door Opener Installation Instructions and User Guide FS 600 FS 1000 FS 1200 600N 1000N 1200N FS 600-Speed FS 1000-Speed 600N 1000N S/N WARNING Please read the manual carefully before

More information