Internal Gear Pump / Drive QT, QX, QXV, QXM series. Operating manual. Bucher Hydraulics GmbH Industriestrasse 1 D Klettgau

Size: px
Start display at page:

Download "Internal Gear Pump / Drive QT, QX, QXV, QXM series. Operating manual. Bucher Hydraulics GmbH Industriestrasse 1 D Klettgau"

Transcription

1 Internal Gear Pump / Drive QT, QX, QXV, QXM series Operating manual Bucher Hydraulics GmbH Industriestrasse 1 D Klettgau / VPZ / Operating manuel 100-I E-00 Observe protection notice according to ISO Subject to changes. 1 / 26

2 Table of contents Table of contents 1 About this document Valid scope Target groups Other applicable documents Warning labels and symbols Series Security Intended use General safety instructions Product safety Operator's obligations Duties of the operating staff Special hazards Potentially explosive areas Hazardous pumped liquids Layout and function Labels Type plate Pump type code Construction Transport, storage and disposal Transport Unpacking and inspection on delivery Lifting Preservation Storage Remove the preservative Disposal Setup and connection Preparing the installation Check the environment Prepare the installation site Remove the preservative Choose orientation for the installation Assembly Planning the piping Avoid contamination of the piping Lay out supports and flange connections Specify nominal diameters Specify pipe lengths Optimise cross-section and bends Arrange for safety and monitoring devices (recommended) Connecting the pipes Install the suction pipe Install the pressure pipe Check that pipe connections are stress-free Install any additional functions Install connection for leaking oil Install cooling/heating Connect the electrics Connect the motor Check the direction of rotation Operation Preparations for the initial start-up Identify the pump type Cool or heat the pumped liquid Fill the system Check the connection for leaking oil Start-up Switch-on Switch-off Interrupting operation Returning to operation Maintenance Inspections Maintenance Antifriction bearing Replace radial shaft seal ring Returning the pump to the manufacturer Assembly Ordering replacement parts Disturbance recovery QT, QX, QXV pumps QXM (drive) Appendix Technical specifications Ambient conditions Noise pressure level Tightening torque for cover/flange Pumped liquid Viscosity Contamination class Run-in cycle Flow speed Pump input pressure Preservative Cleaning agents Spare parts / I E-00 /

3 Table of contents List of figures List of tables Fig. 1 Type plate (example)... 8 Fig. 2 Pump type code (example)... 8 Fig. 3 QX low pressure pump (pressure range 1)... 9 Fig. 4 QX low pressure pump (pressure range 2)... 9 Fig. 5 QX high pressure pump (pressure range 3) Fig. 6 Fastening the lifting gear to the pump Fig. 7 Run-in cycle QT/QX/QXM overall run-in time 10 minutes Fig. 8 Run-in cycle QXV overall run-in time 21 minutes Tab. 1 Target groups and their duties... 4 Tab. 2 Other applicable documents and their purpose... 4 Tab. 3 Warning labels and consequences of disregarding them... 5 Tab. 4 Symbols and their meaning... 5 Tab. 5 Series and function... 5 Tab. 6 Special versions (extract)... 8 Tab. 7 Action to be taken for operational interruptions Tab. 8 Actions to be taken after prolonged shutdown periods Tab. 9 Assignment of fault numbers QT, QX, QXV pumps Tab. 10 Fault table QT, QX, QXV pumps Tab. 11 Assignment of fault numbers - QXM (drive) Tab. 12 Fault table QXM (drive) Tab. 13 Ambient conditions Tab. 14 Tightening torque for cover/flange Tab. 15 Pumped liquid by group Tab. 16 Categories of pumped liquids Tab. 17 Viscosity Tab. 18 Contamination class Tab. 19 Flow speed (recommended) Tab. 20 Pump input pressure (absolute) - minimum Tab. 21 Pump input pressure (absolute) - maximum Tab. 22 Spare parts I E-00 / /26

4 About this document 1 About this document 1.1 Valid scope In this manual, all series, even the QXM drive, will be generally called pumps. This manual is part of the pump, applies to all of the pump series mentioned above, describes safe and appropriate operation during all operating phases. 1.2 Target groups Target group Operating company Qualified staff, fitter Duty Keep this manual available where the device is used, including for later use. Ensure that personnel read and follow the instructions in this manual and the other applicable documents, especially all safety information and warnings. Observe any additional rules and regulations referring to the installation. Read, observe and follow this manual and the other applicable documents, especially all safety information and warnings. Tab. 1 Target groups and their duties 1.3 Other applicable documents Document ATEX additional instructions 100-I Technical description Installation and commissioning for internal gear pumps and motors, series QX, QXM, QXV, QT and QR Purpose Only when operated in potentially explosive areas Brochure and confirmation of order with technical details and operating limits Brief introduction (supplied with every pump) Tab. 2 Other applicable documents and their purpose 4/ I E-00 /

5 About this document 1.4 Warning labels and symbols Warning label Risk level Consequences of disregard DANGER WARNING Immediate acute risk Potential acute risk Potentially hazardous situation Potentially hazardous situation Fatal injury, grievous bodily harm Fatal injury, grievous bodily harm Minor bodily harm Material damage Tab. 3 Symbol Warning labels and consequences of disregarding them Meaning Safety warning sign Take note of all information highlighted by the safety warning sign and follow the instructions to avoid injury or death. Instruction 1., 2.,... Multiple step instructions Precondition Cross reference Information, note Tab. 4 Symbols and their meaning 1.5 Series Pump series Function QT Internal gear pump 1) QX Internal gear pump 1) QXV Internal gear pump for low viscosity liquids 1) QXM Internal gear drive 1) Tab. 5 Series and function 1) called pump in the following 100-I E-00 / /26

6 Security 2 Security The manufacturer does not accept any liability for damage resulting from disregard of the entire documentation. 2.1 Intended use Only use the pump to pump the agreed liquids ( Technical description). Maintain operating limits and size-dependent minimum flow rate. Do not allow to run dry. Damage occurs within a few seconds. Make certain that the pump is never commissioned and never operated without a pumped liquid. Avoid cavitation: Maintain minimum pressure at pump input ( Pump input pressure, Page 26). Avoid overheating: Maintain permissible values of pressure, temperature, speed of rotation and on-time. Avoid damage to motor: Do not open the pressure release valve beyond the agreed operating point. Do not exceed the allowed number of motor switch-ons per hour ( Manufacturer's specifications). Consult with the manufacturer about any other use of the pump. 2.2 General safety instructions Take note of the following instructions before carrying out any work Product safety The pump has been constructed using the latest technology and accepted technical safety rules. Nevertheless, operation of the pump can involve risk to life and health of the user or of third parties, or risk of damage to the pump and other property. Only operate the pump if it is in perfect technical condition; only use it as intended, staying aware of safety and risks, and adhering to the instructions in this manual. Keep this manual and all other applicable documents complete, legible and accessible to staff at all times. Refrain from any procedures that would endanger staff or third parties. Should there be any safety-relevant fault, deactivate the pump immediately and have the fault corrected by responsible personnel. In addition to the entire documentation for the product, always comply with statutory or other safety and accidentprevention rules as well as with the applicable standards and guidelines in the country where the pump is operated. Prevention of obvious misuse (examples) Observe the operating limits of the pump regarding temperature, pressure, flow rate and speed of rotation ( Technical description). 6/ I E-00 /

7 Security Operator's obligations Safety-conscious operation Only operate the pump if it is in perfect technical condition; only use it as intended, staying aware of safety and risks, and adhering to the instructions in this manual. Ensure that the following are observed and monitored: adherence to intended use, statutory or other safety and accident-prevention rules, safety regulations governing the handling of hazardous substances, applicable standards and guidelines in the country where the pump is operated. Make protective equipment available. Staff qualifications Make certain that all personnel tasked with work on the pump have read and understood this manual and all other applicable documents, especially the safety, maintenance and repair instructions, before they begin the job. Organize responsibilities, who is in charge of any specific duty and how personnel is supervised. Ensure that all work is carried out by specialist technicians only: fitting, repair and maintenance work, work on the pump electrical system. Make certain that trainee personnel may only work on the pump when supervised by a specialist technician. Safety installations Provide the following safety installations and verify their integrity: for hot and moving parts: on-site protection against accidental contact with the pump, if electrostatic charging is possible: fit appropriate earthing Duties of the operating staff Observe and keep legible all instructions given on the pump, e.g. the arrow indicating the direction of rotation and the markings for fluid connections. Do not remove the protection against accidental contact for hot, cold and moving parts during operation. Use protective equipment if necessary. Carry out work on the pump only while the pump is not running. Isolate the motor from its supply voltage and keep it locked in that state while carrying out any fitting or maintenance work. Mount the safety installations on the pump according to regulations after completion of work on the pump. 2.3 Special hazards Potentially explosive areas ( ATEX additional instructions) Hazardous pumped liquids Observe the safety regulations for the handling of hazardous substances when working with hazardous pumped liquids (e.g. hot, flammable, explosive, poisonous or potentially harmful). Use protective equipment when carrying out any work on the pump. Warranty Obtain the manufacturer's approval prior to carrying out any modification, repair or alterations during the warranty period. Only use original parts or parts that have been approved by the manufacturer. 100-I E-00 / /26

8 Layout and function 3 Layout and function 3.1 Labels Pump type code Type plate QX R 0 9 Type P d bar V g cm 3/U 3 5 Nr. 4 6 MADE IN GERMANY Fig. 1 Type plate (example) 1 Pump type 2 Constant pressure [bar] 3 Geometrical displacement/delivery/swallowing [cm 3 /rev.] 4 Serial number Fig. 2 Pump type code (example) 1 Pump series 2 Size 3 Pressure range 4 Displacement/delivery/swallowing [cm 3 /rev.] 5 Direction of rotation (R=clockwise, L=anticlockwise, N=both) 6 Special version (optional) The following table shows an extract from possible special versions. Number 06 Characteristic Separate connection for leaking oil QX 2-5 G 1/4" QX 6 G 3/8" QX 8 G 1/2" 09 FPM (Viton) sealing material 12 2 hole fixing flange according to ISO 3019/2 (metric) 14 Operating temperature up to 160 C 29 Hydraulic liquid HFB and HFC, size hole fixing flange according to ISO 3019/2 (metric) vacuum connection for QX 61 SAE 2" QX 81 SAE 2.5" 86 Hydraulic liquid HFB and HFC, size Tab. 6 Special versions (extract) 8/ I E-00 /

9 Layout and function 3.2 Construction x-x x P x 5 S Fig. 3 QX low pressure pump (pressure range 1) 1 Pump shaft 2 Flange with radial shaft seal rings 3 Antifriction bearing 4 Gear wheels 5 Gear wheel housing 6 Plain bearing 7 Housing x-x 7 6 x 6 P x S Fig. 4 QX low pressure pump (pressure range 2) 1 Pump shaft 2 Flange with radial shaft seal rings 3 Antifriction bearing 4 Gear wheels 5 Gear wheel housing 6 Plain bearing 7 Housing 100-I E-00 / /26

10 Layout and function x-x x P x S Fig. 5 QX high pressure pump (pressure range 3) 1 Pump shaft 2 Flange with radial shaft seal rings 3 Antifriction bearing 4 Gear wheels 5 Connection for leaking oil (optional) 6 Gear wheel housing 2 7 Plain bearing 8 Gear wheel housing 1 9 Housing 10 / I E-00 /

11 Transport, storage and disposal 4 Transport, storage and disposal 4.1 Transport Lifting Weight ( Technical description) Unpacking and inspection on delivery 1. Unpack the pump on delivery and inspect for transport damage. 2. Report any transport damage to the manufacturer without delay. 3. Dispose of packaging material according to local regulations. DANGER Death or crushed limbs caused by falling loads! Use lifting gear appropriate for the total weight to be lifted. Fasten the lifting gear as shown in the illustrations below. Do not stand under suspended loads. 1 Fig. 6 Fastening the lifting gear to the pump 1. If only one thread is available for eye bolt, put the second sling around the end of the pump. 2. Lift the pump properly. 100-I E-00 / / 26

12 Transport, storage and disposal 4.2 Preservation Only necessary when storing. 4.4 Remove the preservative Only necessary for pumps which have been preserved for storage. Material damage due to improper storage! Preserve the pump properly inside and out for storage. 1. Select preservative according to the type and duration of storage ( Preservative, Page 26). 2. Use the preservative as specified by the manufacturer. 3. Apply the preservative to all bare metal surfaces inside and out. 4.3 Storage Material damage due to inappropriate storage! Preserve and store the pump properly. 1. Seal all openings with blank flanges, blind plugs or plastic covers. 2. Make certain that the storage room meets the following conditions: dry frost-free vibration-free 3. Turn shaft once a month. 4. Make certain that the shaft and the bearing change their rotational position in the process. WARNING Danger of poisoning due to preservative and cleaning agent in the vicinity of foodstuffs or drinking water! Only use cleaning agents compatible with the pumped liquid ( Cleaning agents, Page 26). Completely remove any preservative. Damage to seals through incorrect cleaning agent! Ensure that the cleaning agent does not attack the seals. 1. Select the cleaning agent according to the area of use. ( Cleaning agents, Page 26). 2. Dispose of preservative according to local regulations. 4.5 Disposal Plastic parts can be contaminated by poisonous or radioactive pumped media to such an extent that cleaning will be insufficient. WARNING Risk of poisoning and environmental damage caused by pumped liquid or oil! Use protective equipment when carrying out any work on the pump. Prior to disposal of the pump: Collect pumped liquid and oil or grease which drain out and dispose of separately according to local regulations. Neutralise residues of pumped liquid in the pump. Remove the preservative ( 4.4 Remove the preservative, Page 12). Dismount plastic parts and dispose of the parts according to local regulations. Dispose of pump according to local regulations. 12 / I E-00 /

13 Setup and connection 5 Setup and connection For pumps in potentially explosive areas ( ATEX additional instructions 100-I ). Material damage caused by dirt! Do not remove transport protection until immediately before installing the pump. Do not remove covers and transport and sealing covers until just before connecting the piping to the pump. 5.1 Preparing the installation Check the environment 1. Make certain that the required environmental conditions are met ( Ambient conditions, Page 24). 2. For installations > 1000 m above sea level, consult with the manufacturer Prepare the installation site Make certain that the installation site meets the following conditions: pump is freely accessible from all sides, sufficient space for installation/removal of the pipes and for maintenance and repair work, especially for the removal and installation of the pump and the motor, pump not exposed to external vibrations (damage to bearings), frost protection Remove the preservative If the pump is to be commissioned directly after installation and connection: Remove any preservative before installation ( 4.4 Remove the preservative, Page 12) Choose orientation for the installation The crescent seal internal-gear pump can be operated in any orientation. 5.2 Assembly Note the brief introduction supplied ( Installation and commissioning for crescent seal internal-gear pumps and motors, series QX, QXM, QXV, QT and QR). Material damage caused by knocks and blows! Do not cant the coupling halves when sliding on. Do not knock or hit any component of the pump. Material damage by recoil force of the coupling! Connect the shaft and the motor with < 0.2 mm misalignment. Material damage due to axial forces! Only operate the pump with direct drive and elastic coupling. 1. Use coupling with H7 tolerance on the coupling bore. 2. Apply a very thin film of molybdenum disulphide (e.g. Molykote) on the pump and motor shaft ends. 3. Insert fitting keys. 4. Without mounting device: Remove rubber buffers and heat coupling halves to approx. 100 C. 5. Slide on the pump-side and motor-side coupling halves until the shaft ends and the coupling centre are flush with each other. Keep the specified distance between the coupling halves ( Assembly instructions for the coupling). 6. Tighten the grub screws on both coupling halves. Freely choose orientation for the installation. 100-I E-00 / / 26

14 Setup and connection 5.3 Planning the piping Use flexible piping (recommended). For fixed piping use seamless precision steel piping to DIN 2391 (recommended) Avoid contamination of the piping Materialdamageduetoimpuritiesinthepump! Make certain that no impurities can get into the pump. 1. Clean all piping components and armatures prior to assembly. 2. Ensure that no flange gaskets are protruding inwards. 3. Remove blank flanges, plugs, protective films and/or protective paints from the flanges Lay out supports and flange connections Material damage due to excessive force and torque from piping to pump! Minimise pipe forces and take every possible operating condition into account: cold/warm empty/full unpressurised/pressurised shift in position of flanges Ensure that pipe can slide freely in the supports and will not seize up through corrosion Arrange for safety and monitoring devices (recommended) Avoid contamination 1. Note permissible contamination ( Contamination class, Page 25). 2. Integrate filter into the suction pipe. 3. To monitor contamination, fit a differential manometer with a contact manometer. Avoid excessive pressure Fit a pressure-relief valve. Avoid overheating Enable a temperature monitor to turn the pump off. Avoid reverse operation Install a non-return valve between the pressure joint and the stop valve to ensure that the liquid will not flow back whenthepumpisswitchedoff. Provide for isolating and shut-off devices for the pipes For maintenance and repair work Fit stop valves before and after the pump. Enable measurement of the operating conditions 1. For pressure measurements, fit manometers before and after the pump. 2. Provide for motor torque measurements. 3. Provide for pump temperature measurements Specify nominal diameters Keep flow resistance in pipes as low as possible. 1. Set the nominal diameters to correspond to the size and to the pipe flanges. 2. Note the maximum flow speeds ( Flow speed, Page 26) Specify pipe lengths Set the maximum length of pipe network according to pressure at pump input ( Pump input pressure, Page 26) Optimise cross-section and bends 1. Avoid bends with radius of less than 1.5 times the pipe diameter. 2. Avoid abrupt changes of cross-section in the pipe network. 14 / I E-00 /

15 Setup and connection 5.4 Connecting the pipes Damage due to impurities in the pump! Ensure that no impurities can get into the pump Install the suction pipe 1. Remove transport and sealing covers from the pump. 2. Avoid air pockets: Run pipes with a continuous slope up to the pump. 3. Ensure that no gaskets protrude inwards. 4. For hydraulic systems: Connect the suction pipe to the tank a few cm below the minimum liquid level Install the pressure pipe 1. Remove transport and sealing covers from the pump. 2. Fit the pressure pipe. 3. Ensure that no gaskets protrude inwards Check that pipe connections are stress-free Pipe installed and cooled down 1. Separate the connecting flanges of the pipes from the pump. 2. Check that pipes can move freely in all directions they might be expected to expand. 3. Make certain that the flange surfaces are parallel. 4. Reconnect the pipe flanges to the pump. 5.5 Install any additional functions Install connection for leaking oil With QXV/QXM, to recycle leaks back into the pumped liquid circuit. With QX/QT, this is only possible if the pump is ordered accordingly. 5.6 Connect the electrics DANGER Risk of fatal injury through electric shock! Have all electrical work carried out by qualified electricians only. DANGER Risk of fatal injury due to rotating parts! When carrying out any fitting or maintenance work, isolate the motor from its supply voltage and keep it locked in that state Connect the motor Follow the manufacturer's instructions. 1. Connect the motor according to the circuit diagram. 2. Ensure that the electrical energy does not present any risk. 3. Install an EMERGENCY OFF switch Check the direction of rotation Damage caused by running dry! Decouple the motor from the pump. As default setting, the pump rotates clockwise. Anti-clockwise is also possible. 1. Switch motor on and immediately off again. 2. Check that the motor's direction of rotation corresponds to the arrow showing the direction of rotation on the pump. 3. If the direction of rotation is different: swap two phases. 4. Recouple the motor to the pump. Damage caused by overheating! Collect leaking oil < 1.5 bar absolute in tank. Ensure that connection dimensions for leaking oil are adequate and take the shortest route to the tank. Install connection for leaking oil with screw in fitting on the pump Install cooling/heating Recommended for the ideal temperature of the pumped liquid ( Ambient conditions, Page 24). 1. Choose heating or cooling as your environment dictates. 2. Install the connections and then install the cooling/heating as specified by the manufacturer. 100-I E-00 / / 26

16 Operation 6 Operation For pumps in potentially explosive areas ( ATEX additional instructions 100-I ). 6.1 Preparations for the initial start-up Identify the pump type Identify the pump type ( Technical description) Cool or heat the pumped liquid For cooling or heating liquid ensure: adequate quantity required parameters Fill the system WARNING Risk of injury and poisoning due to hazardous pumped liquids! Safely collect any leaking pumped liquid and dispose of it in accordance with environmental rules and requirements. Material damage due to incorrect or contaminated pumped liquid! Use approved pumped liquid ( Pumped liquid, Page 24). Note permissible viscosity ( Viscosity, Page 24). Note permissible contamination ( Contamination class, Page 25). Damage caused by running dry! Make certain that the pump is properly filled. When operating pump: Ensure minimum liquid level in tank. 1. Fill the pump and the suction pipe with pumped liquid. Fill the pump and suction pipe with pumped liquid by turning the pump by hand or by pulsing the drive (recommended). 2. Switch motor on and pressurise pumped liquid with 20 bar (consult manufacturer for higher pressure). 3. Ensure that no joints or connections leak Check the connection for leaking oil Collect leaking oil with < 1.5 bar absolute in a tank. 6.2 Start-up Switch-on The pump is correctly installed and connected The motor is correctly installed and connected All connections are stress-free and leak-free All safety installations have been fitted and tested for integrity The pump has been correctly prepared, filled and bled DANGER Risk of injury due to running pump! Do not touch the running pump. Do not carry out any work on the running pump. Allow the pump to cool down completely before starting any work on it. DANGER Risk of injury and poisoning caused by pumped liquid spraying out! Use protective equipment when carrying out any work on the pump. Damage caused by running dry! Make certain that the pump is properly filled. Ensure minimum liquid level in tank. Damage through cavitation! To bleed the pump operate pressure free. Only pressurise pumped liquid that has been completely bled. Damage caused by temperature shock! Ensure that the temperature difference between the pump and the pumped liquid is < 25 C. 1. Note run-in cycle ( Run-in cycle, Page 25). 2. Switch on the motor and check that it runs smoothly. 3. After the first start, switch the pump off and wait until there are no more air pockets in the pumped liquid. 4. Switch motor on and pressurise pumped liquid with 20 bar (consult manufacturer for higher pressure). 5. After the initial stress caused by pressure and operating temperature, check that the pump is not leaking. 6. Increase the pressure as specified in the run-in cycle. 16 / I E-00 /

17 Operation 7. After the initial stress caused by pressure and operating temperature, check that the pump is not leaking Switch-off The pressure-side valve is closed (recommended) WARNING Risk of injury caused by hot pump parts! Use protective equipment when carrying out any work on the pump. 1. Switch the control to circulate to the tank. 2. Switch off the motor. 3. Check all fixing bolts and tighten if necessary. 6.3 Interrupting operation WARNING 6.4 Returning to operation 1. After shutdowns, take the following actions before restarting the pump: Shutdown duration Action > 6 months Return QXV pumps to manufacturer. Other pumps: Replace shaft seal with repair kit ( 9.2 Spare parts, Page 26). >2years Tab. 8 Return pumps to manufacturer. Actions to be taken after prolonged shutdown periods 2. Carry out all steps as for the initial start-up ( 6.2 Start-up, Page 16). Risk of injury and poisoning due to hazardous pumped liquids! Safely collect any leaking pumped liquid and dispose of it in accordance with environmental rules and requirements. Carry out the following measures when operation is interrupted: Pump is emptied disassembled Action Close stop valves on both sides of pump. Isolate the motor from its power supply and secure against unauthorized switch-on. put into storage Tab. 7 Pump preserve ( 4.2 Preservation, Page 12). store ( 4.3 Storage, Page 12). Action to be taken for operational interruptions 100-I E-00 / / 26

18 Maintenance 7 Maintenance For pumps in potentially explosive areas ( ATEX additional instructions 100-I ). Trained service technicians are available for fitting and repair jobs. 7.1 Inspections The inspection intervals depend on the load placed on the pump. 7.2 Maintenance DANGER Risk of injury due to running pump! Do not touch the running pump. Do not carry out any work on the running pump. When carrying out any fitting or maintenance work, isolate the motor from its supply voltage and keep it locked in that state. DANGER Risk of injury due to running pump! Do not touch the running pump. Do not carry out any work on the running pump. WARNING Risk of injury and poisoning due to hazardous pumped liquids! Use protective equipment when carrying out any work on the pump. 1. Check at appropriate intervals: compliance with minimum flow rate normal operating conditions unchanged for hydraulic systems: check liquid level in tank and check hydraulic liquid for viscosity, ageing and contamination coupling alignment and condition of elastic elements 2. For trouble-free operation, always ensure the following: no dry running no leaks no cavitation suction-side gate valves open unobstructed and clean filters sufficient supply pressure no unusual running noises and vibrations no excessive leakage at the shaft seal proper functioning of auxiliary operating systems DANGER Risk of fatal injury through electric shock! Have all electrical work carried out by qualified electricians only. WARNING Risk of injury and poisoning due to hazardous or hot pumped liquids! Use protective equipment when carrying out any work on the pump. Allow the pump to cool down completely before commencing any work. Make certain that the pump is unpressurised. Empty the pump, safely collect the pumped liquid and dispose of it in accordance with environmental rules and requirements. Damage due to disassembly of the pump! Do not take the pump to pieces. Return faulty pumps to the manufacturer ( 7.3 Returning the pump to the manufacturer, Page 19). For QT, QX and QXM pumps, only the repair set can be replaced ( 9.2 Spare parts, Page 26) Antifriction bearing Faulty antifriction bearings increase noise levels, torque or temperature. Return pumps with faulty bearings to the manufacturer ( 7.3 Returning the pump to the manufacturer, Page 19). 18 / I E-00 /

19 Maintenance Replace radial shaft seal ring Replace cover/flange with faulty radial shaft seal ring with repair set ( 9.2 Spare parts, Page 26). 1. Remove pump from system. 2. Remove fitting key from pump shaft. 3. Remove cheese head bolts from cover/flange. 4. Pull off cover/flange with old radial shaft seal ring from shaft. 5. Grease pump shaft. 6. Slide repair set onto shaft and fix in place with cheese head bolts. 7. Fit fitting key into pump shaft. 7.3 Returning the pump to the manufacturer Pump is unpressurised Pump is completely empty Electrical connections are isolated and the motor is secured against switch-on Pump has cooled down Coupling guard has been removed For couplings with a spacer: Spacer has been removed Auxiliary operating systems are shut down, unpressurised and emptied Manometer connections, manometer and fixtures have been removed 1. Flush the pump and decontaminate if hazardous liquid has been pumped. 2. Return the complete pump (not disassembled) to the manufacturer. 7.4 Assembly 1. Keep to specified torque ( Technical description). 2. Fit the pump into the system ( 5 Setup and connection, Page 13). 7.5 Ordering replacement parts For trouble-free replacement in case of any damage we recommend keeping replacement pumps or spare parts available on site ( 9.2 Spare parts, Page 26). To order spare parts keep the pump type ready ( type plate). 100-I E-00 / / 26

20 Disturbance recovery 8 Disturbance recovery 8.1 QT, QX, QXV pumps For faults that do not appear in the following table or faults that cannot be traced back to the suggested causes, please consult with the manufacturer. Possible faults are identified by a fault number in the table below. Use this number to find cause and remedy in the troubleshooting list. Fault Number Pump not pumping 1 Pumping rate insufficient 2 Pumping rate excessive 3 Pumping pressure insufficient 4 Pumping pressure excessive 5 Pump running roughly 6 Roller bearing temperatures too high 7 Pump leaking 8 Motor power uptake excessive 9 Tab. 9 Assignment of fault numbers QT, QX, QXV pumps Fault number Cause Remedy X Transport and sealing cover not removed Remove transport and sealing cover. If damage caused by running dry, return to the manufacturer. X Supply/suction line and/or pressure line closed by valve Open the valve. X Liquid level in the tank < minimum Top up the pumped liquid. X Coupling destroyed Replace the coupling. X Suction pipe too short Lengthen suction pipe. X X X Suction pipe leaking Tighten bolts on pipes or flanges. Seal thread. X X X Motor speed insufficient Compare required rotational speed of motor with type plate on pump. Replace motor if necessary. Increase motor speed, if speed control available. X X Supply/suction pipe not fully opened Open the armature. X X Faulty control Repair control. X X Burst pipe underneath tank lid Replace pipe. X X X X Supply/suction pipe, pump or suction strainer blocked or encrusted X X X Supply/suction pipe cross-section too narrow Clean supply/suction pipes, pump or suction strainer. Increase cross-section. 20 / I E-00 /

21 Disturbance recovery Fault number Cause Remedy X X X Hydraulic components of the pump dirty, clotted or encrusted X X Supply/suction pipe and pump not bled properly or not filled up completely Return pump to manufacturer. Clean the components. Fill up pump and/or piping completely and bleed them. X X Supply/suction line contains air pockets Install armature for bleeding. Correct piping layout. X X X X Air sucked in Seal source of malfunction. X X X X Excessive amount of gas: pump is cavitating X X X Viscosity or density of the pumped liquid outside the specified range for the pump X X X Temperature of pumped liquid too high: pump is cavitating X X X Pressure-side armature not opened sufficiently Consult with manufacturer. Consult with manufacturer. Increase supply pressure. Lower temperature. Inquire with manufacturer. Open pressure-side armature. X X X X Pressure pipe blocked Clean pressure pipe. X X X X Pump rotating the wrong way Swap any two phases at the motor. X X X X Pump components worn Return pump to manufacturer. X X X X X Motor speed excessive Compare required rotational speed of motor with type plate on pump. Replace motor if necessary. Reduce motor speed with speed control, if available. X X X Faulty antifriction bearing in pump Return pump to manufacturer. X X Faulty antifriction bearing in motor Replace antifriction bearing. X Connecting bolts not tightened correctly Tighten connecting bolts. X Worn radial shaft seal ring Return QXV pumps to manufacturer. Other pumps: replace shaft seal with repair kit ( 9.2 Spare parts, Page 26). X Faulty housing seal Return pump to manufacturer. X X X X Pump distorted Check pipe connections and pump fixings. X Worn coupling Replace the coupling. X X X X Motor running on 2 phases Check fuse and replace it if necessary. Tab. 10 Fault table QT, QX, QXV pumps Check cable connections and insulation. 100-I E-00 / / 26

22 Disturbance recovery 8.2 QXM (drive) For faults that do not appear in the following table or faults that cannot be traced back to the suggested causes, please consult with the manufacturer. Possible faults are identified by a fault number in the table below. Use this number to find the cause and remedy in the troubleshooting list. Fault Drivedoesnotstart 1 Drive rotates too slowly 2 Drive rotates too quickly 3 Insufficient torque 4 Insufficient power delivered 5 Driveisleaking 6 Tab. 11 Number Assignment of fault numbers - QXM (drive) 22 / I E-00 /

23 Disturbance recovery Fault number Cause Remedy X Transport and sealing cover not removed Remove transport and sealing cover. X Supply and/or pressure line closed by valve Open valve. X Coupling destroyed Replace coupling. If damage caused by running dry, return to the manufacturer. X X X Rotational speed too low or start up torque too high Compare required rotational speed of drive with type plate. Replace motor if necessary. Increase motor speed, if speed control available. X X Supply/drain pipe not fully opened Open armature. X X Faulty control Repair control. X X X X Supply/drain pipe, drive blocked or encrusted Clean supply/drain pipe, drive. X X X Supply/drain pipe cross-section too narrow Increase cross-section. X X X Hydraulic components of the pump dirty, clotted or encrusted Return drive to manufacturer. X X X X Excessive amount of gas Consult with manufacturer. X X Viscosity or density of the pumped liquid outside the specified range for the drive Consult with manufacturer. X X X Temperature of pumped liquid too high Lower temperature. Inquire with manufacturer. X X X X Drive rotates in wrong direction Exchange connections for supply and drain pipes. X X X Pump components worn Return pump to manufacturer. X X X Excessive supply Compare required rotational speed of drive with type plate. Replace motor if necessary. Reduce supply. Reduce motor speed with speed control, if available. X Drive distorted Check pipe connections and drive fixings. X Worn coupling Replace coupling. Tab. 12 Fault table QXM (drive) 100-I E-00 / / 26

24 Appendix 9 Appendix 9.1 Technical specifications Further technical details ( Technical description) Ambient conditions Consult with the manufacturer about operation under other ambient conditions. Temperature [ C] 1) 20 to +80 ideal +30 to +50 Relative humidity [%] permissible longterm shortterm Installation height above sea level [m] Tab. 13 Ambient conditions 1) depends on permissible viscosity, amongst other things 2) consult with the manufacturer for higher installation Pumped liquid HLP and HFC For series QT, QX, QXM, QXV QT, QX, QXM Noise pressure level For exact details on noise pressure level ( Technical description). Pumped liquid (group) Max. load [N/mm 2 ] 3) Temperature [ C] HLP 1) HFC 2) Tab. 15 Pumped liquid by group 1) hydraulic oils to DIN 51524, part 2 2) low flammability hydraulic liquid to DIN ) recommended by Brugger DIN Precondition Pumped liquid corresponds to permissible viscosity Pump/motor is a special version Other pumped liquids For series Pumped liquid Tightening torque for cover/flange Repair set Pump type Tightening torque [Nm] QX, QXM QX2 10 ± 2 QX3 20 ± 2 QX4 40 ± 5 QX5 80 ± 10 QX6 160 ± 10 QT, QX, QXM QXV Tab. 16 Mineral oils/synthetic liquids Turbine oils/biologically degradable oils Low viscosity mineral oils Fuels Low flammability liquid (HFA) Calibrating liquids (for test rigs) amongst others Categories of pumped liquids QT Tab. 14 QX8 320 ± 20 QT2 10 ± 2 QT3 10 ± 2 QT4 10 ± 2 QT5 20 ± 2 QT6 20 ± 2 QT8 20 ± 2 Tightening torque for cover/flange Viscosity For series Viscosity [mm 2 /s] QT QX, QXM QXV Tab. 17 Viscosity 24 / I E-00 /

25 Appendix Contamination class For series Class to NAS 1638 to ISO 4406 QT, QX, QXM 9 20/18/15 QXV 8 19/17/14 Tab. 18 Contamination class Run-in cycle y 100 1s 2s 3s 1s 2s 3s 120s 100s 1s 2s 3s s 0 140s 20s s 10s x 1s 2s 2s 3s 3s 3s 5s Fig. 7 Run-in cycle QT/QX/QXM overall run-in time 10 minutes x time [min] y working pressure [%] y 1s 2s 3s 100 1s 2s 3s 240s 1s 2s 3s 240s s 0 280s 20s 30s 14s x 1s 2s 2s 3s 3s 3s 5s Fig. 8 Run-in cycle QXV overall run-in time 21 minutes x time [min] y working pressure [%] 100-I E-00 / / 26

26 Appendix Flow speed QT, QX, QXV pumps QXM (drive) Suction pipe [m/s] Pressure pipe [m/s] P1 [m/s] P2 [m/s] Tab. 19 Flow speed (recommended) Pump input pressure If in doubt ask manufacturer about pump input pressure. Minimum [bar] 1) Start phase Long-term Mineral oil HFC Low viscosity Tab. 20 Pump input pressure (absolute) - minimum 1) Depending on size and pumped liquid Maximum [bar] Standard version Special version 1.5 > 1.5 1) Tab. 21 Pump input pressure (absolute) - maximum 1) for QT and QX series external connection for leaking oil required Preservative High quality, mineral oil to DIN CL 46 or to ISO 3448 VG46(recommended) Cleaning agents Benzine, wax solvents, diesel, petrol, alkaline cleaners 9.2 Spare parts Type of drive Repair set Version QT QT Cover complete with radial shaft seal ring, spacer disc and O-ring QX QXM QX Flange complete with radial shaft seal ring, spacer disc and O-ring QXV Tab. 22 Spare parts Leaky pumps must be returned to the factory ( 7.3 Returning the pump to the manufacturer, Page 19). 26 / I E-00 /

Pressure relief valve

Pressure relief valve Pressure relief valve Operating manual Series DHV 712 Version BA-2015.10.20 EN Print-No. 300 510 TR MA DE Rev001 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 32602 Vlotho Germany Phone: +49 (0) 5733-799-0

More information

Standard Chemical Pump

Standard Chemical Pump Standard Chemical Pump Operating instructions MPC-B series Version BA-2006.03 Print-No. 01 VM-No. EN Munsch Chemie-Pumpen GmbH Im Staudchen 56235 Ransbach-Baumbach Germany Phone: +49 (0) 26 23-8 98-90

More information

Screw Pump. Version BA ID-No VM-No GB. We reserve the right to make technical changes.

Screw Pump. Version BA ID-No VM-No GB. We reserve the right to make technical changes. Screw Pump Original Operating Manual ALLFUEL Series Version BA-2010.12 ID-No. 550 833 VM-No. 626.0007 GB ALLWEILER AG Radolfzell plant Postfach 1140 Allweilerstraße 1 78301 Radolfzell Germany Phone: +49

More information

Centrifugal Pump with Volute Casing

Centrifugal Pump with Volute Casing Centrifugal Pump with Volute Casing Original Operating Manual NIM / NAM series Version BA-2014.09 ID-No. 550 018 VM-No. 467.0001 GB ALLWEILER GmbH Postfach 1140 Allweilerstr. 1 78301 Radolfzell Germany

More information

Screw Pump. Version BA ID-No VM-No GB

Screw Pump. Version BA ID-No VM-No GB Screw Pump Original Operating Manual SNC, SNG, SNFG Series Version BA-2014.01 ID-No. 550 159 VM-No. 655.0003 GB ALLWEILER GmbH Postfach 1140 Allweilerstraße 1 78301 Radolfzell Germany Phone: +49 (0) 7732-86-0

More information

Gear pump with magnetic coupling

Gear pump with magnetic coupling Gear pump with magnetic coupling Original Operating Manual Verder Gear Process PFA P1...P7 series Version BA-2013.09 Print-No. 09/13 Verder Deutschland GmbH & Co. KG Retsch-Allee 1 5 42781 Haan Germany

More information

Operating Instructions

Operating Instructions Operating Instructions BE2700 Brinkmann Immersions pumps of the series TA/STA/TAL/SAL901... 1303 Contents 1 General...1 2 Safety...2 3 Transport and storage...2 4 Description of product and accessories...2

More information

Assembly and Maintenance Manual Type AS

Assembly and Maintenance Manual Type AS Assembly and Maintenance Manual Type AS Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_AS.docx

More information

Assembly and Maintenance Manual Type ASNU

Assembly and Maintenance Manual Type ASNU Assembly and Maintenance Manual Type ASNU Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_ASNU.docx

More information

Original Operating Manual SKT Volute-Casing Centrifugal Pump

Original Operating Manual SKT Volute-Casing Centrifugal Pump Original Operating Manual SKT Volute-Casing Centrifugal Pump OSNA-Pumpen GmbH Brückenstrasse 3 49090 Osnabrück, Germany Phone: +49 541 1211-0 Fax: +49 541 1211-220 Internet: http://www.osna.de E-mail:

More information

Swing Piston Compressors and Vacuum Pumps

Swing Piston Compressors and Vacuum Pumps Swing Piston Compressors and Vacuum Pumps NPK 018 AC Pressure NPK 018 DC Pressure NPK 018 AC Vacuum NPK 018 DC Vacuum Operating and Installation Instructions Read and observe these Operating and Installation

More information

Assembly and Maintenance Manual Type RSBW

Assembly and Maintenance Manual Type RSBW Assembly and Maintenance Manual Type RSBW Hatschekstr. 36 69126 Heidelberg Germany Tel +49(0)6221 30470 Tel +49(0)6221 304731 info@stieber.de www.stieber.de Stieber Clutch Date of issue: 16/03/2017 GB

More information

Instruction Manual. Sewage lifting station compli 300

Instruction Manual. Sewage lifting station compli 300 Instruction Manual Sewage lifting station compli 300 Safety instructions Areas of application Electrical connection Installation Servicing Technical data Appendix JUNG PUMPEN GmbH Industriestr. 4-6 33803

More information

Internal Gear Unit. for motor/pump function Series QXM. Reference: 100-P EN-10 1/16. Issue:

Internal Gear Unit. for motor/pump function Series QXM. Reference: 100-P EN-10 1/16. Issue: Internal Gear Unit for motor/pump function Series QXM Reference: -P-63-EN-1 Issue: 1.218 1/16 2/16 -P-63-EN-1/1.218 Contents Page 1 General... 5 1.1 Product description... 5 1.2 Advantages... 5 1.3 Application...

More information

Peristaltic Industrial Tube Pump

Peristaltic Industrial Tube Pump Peristaltic Industrial Tube Pump Operating Manual Rapide Version 1.0v-05/2013 Print No. 01 Version 1.0v-05/2013 Print-No. 01 Rapide The information in this document is essential for the safe operation

More information

Internal Gear Unit. for motor/pump function Series QXM. Reference: 100-P US-10 1/18. Issue:

Internal Gear Unit. for motor/pump function Series QXM. Reference: 100-P US-10 1/18. Issue: Internal Gear Unit for motor/pump function Series QXM Reference: 1-P-63-US-1 Issue: 1.218 1/18 2/18 1-P-63-US-1/1.218 Contents Page 1 General... 5 1.1 Product description... 5 1.2 Advantages... 5 1.3 Application...

More information

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Contents Section 1. General Observations... 2 2. Operation... 4 3. Control During Operation... 5 4. Trouble Shooting... 6 5. Maintenance... 7 Please

More information

Swing Piston Compressors and Vacuum Pumps

Swing Piston Compressors and Vacuum Pumps Swing Piston Compressors and Vacuum Pumps NPK 050 NPK 0100 Operating and Installation Instructions Read and observe these Operating and Installation Instructions! KNF Neuberger GmbH Alter Weg 3 D-79112

More information

Internal Gear Unit. for motor/pump service Series QXM. Reference: 100-P EN-07 1/16. Issue:

Internal Gear Unit. for motor/pump service Series QXM. Reference: 100-P EN-07 1/16. Issue: Internal Gear Unit for motor/pump service Series QXM Reference: -P-63-EN-7 Issue: 8.215 1/16 Contents Page 1 General... 3 1.1 Product description... 3 1.2 Advantages... 3 1.3 Application... 3 1.4 ATEX

More information

Medium and high pressure pumps

Medium and high pressure pumps Screw pumps Medium and high pressure pumps Installation and Start-up Instruction This instruction is valid for all standard high pressure pumps: E4, D4 and D6 Contents Page Pump identification 2 Installation

More information

Original Operating Manual NMH/NMV High-Pressure Centrifugal Pump

Original Operating Manual NMH/NMV High-Pressure Centrifugal Pump Original Operating Manual NMH/NMV High-Pressure Centrifugal Pump OSNA-Pumpen GmbH Brückenstrasse 3 49090 Osnabrück, Germany Phone: +49 541 1211-0 Fax: +49 541 1211-220 Internet: http://www.osna.de E-mail:

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Industrial Process Installation, Operation, and Maintenance Manual Series PBV Plastic Lined Ball Valve Table of Contents Table of Contents Introduction and Safety...2 Safety message levels...2 User health

More information

Diaphragm Vacuum Pumps and Compressors

Diaphragm Vacuum Pumps and Compressors Operating Instructions Read and observe these Operating Instructions! Diaphragm Vacuum Pumps and Compressors N145 AN.18 N145 AT.18 N145 AV.18 N145.1.2 AN.18 N145.1.2 AT.18 N145.1.2 AV.18 KNF Neuberger

More information

Type 3320, Service Manual. Serviceanleitung Service Manuel

Type 3320, Service Manual. Serviceanleitung Service Manuel Electromotive 2/2-way valve Elektromotorisches 2/2-Wege-Ventil Vanne électromotorisée à 2/2 voies Service Manual Serviceanleitung Service Manuel We reserve the right to make technical changes without notice.

More information

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.:

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.: Operating manual HDA eco Box 12/24V DC Automatic Dispenser Item No.: 110 500 900 Translation of the original operating manual Important! Copyright The operating manual is always to be read before commissioning

More information

DIAPHRAGM LIQUID PUMP NF 2.35

DIAPHRAGM LIQUID PUMP NF 2.35 DIAPHRAGM LIQUID PUMP NF 2.35 NF 2.35 XP DC 24V Supply voltage [Ch. 4] DCB-A XP / XT [Ch. 4] 2.35 NF - / PMLxxxx / PLxxxx [Ch. 1] Operating and Installation Instructions Read and observe these Operating

More information

Diaphragm Vacuum Pumps and Compressors

Diaphragm Vacuum Pumps and Compressors Operating Instructions Read and observe these Operating Instructions! Diaphragm Vacuum Pumps and Compressors N022 AN.18 N022 AT.18 N022 AV.18 N026.1.2 AN.18 N026.1.2 AT.18 N026.1.2 AV.18 N026.3 AN.18 N026.3

More information

CENTAX-SEC Series B Assembly and operating instructions CX BFS1-LE/SE-**-B M EN Rev. 1

CENTAX-SEC Series B Assembly and operating instructions CX BFS1-LE/SE-**-B M EN Rev. 1 Assembly and operating instructions -**-B Contents 1 General remarks... 5 2 Safety... 6 2.1 Safety remarks... 6 2.1.1 Signal words... 6 2.1.2 Pictograms... 7 2.2 Qualification of deployed personnel...

More information

Original Operating Manual CVP High-Pressure Centrifugal Pump

Original Operating Manual CVP High-Pressure Centrifugal Pump Original Operating Manual CVP High-Pressure Centrifugal Pump OSNA-Pumpen GmbH Brückenstrasse 3 49090 Osnabrück, Germany Phone: +49 541 1211-0 Fax: +49 541 1211-220 Internet: http://www.osna.de E-mail:

More information

Assembly and maintenance manual Type FSO, FSO-GR, FS, HPI

Assembly and maintenance manual Type FSO, FSO-GR, FS, HPI Type FSO, FSO-GR, FS, HPI Hatschekstr.36 69126 Heidelberg Deutschland Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 23.08.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\M1124E_0_FSO_FSO-GR_FS_HPI.docx

More information

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X Variable Vane Pump, Direct Controlled PV7...A Series 1X / X RE 1 Issue: 1.13 Replaces: 8.8 Sizes 1 to Maximum pressure 1 bar Displacement volume 1 to cm 3 Features Very short control times Low noise Mounting

More information

Type 6213 EV, 6281 EV

Type 6213 EV, 6281 EV Type 6213 EV, 6281 EV 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions

More information

original operating manual Operating manual Translation of the Item-No.: ,

original operating manual Operating manual Translation of the Item-No.: , Translation of the original operating manual Operating manual Item-No.: 015 431 551, 015 431 581 Important! Copyright The operating manual is always to be read before commissioning the equipment. No warranty

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Industrial Process Installation, Operation, and Maintenance Manual Series PBFV Plastic Lined Butterfly Valve - Lug and Wafer Style Table of Contents Table of Contents Introduction and Safety...2 Safety

More information

General operating manual for assembly, commissioning and maintenance of valves and hydraulic manifolds

General operating manual for assembly, commissioning and maintenance of valves and hydraulic manifolds for assembly, commissioning and maintenance of valves and hydraulic manifolds 110210_general_operating_manual 07.2018 Table of contents Contents Page Important information 2 Important safety instructions

More information

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Type range: UN813.3ANI UN813.4ANI UN813.3ANDCB UN813.4ANDCB UN813.5ANI Fig. 1: UN813.3ANI Fig. 2: UN813.4ANI You have selected

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Type 5404 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating instructions...2 2 Intended use...3 3

More information

These installation and maintenance instructions must be read in full and completely understood before the installation!

These installation and maintenance instructions must be read in full and completely understood before the installation! These installation and maintenance instructions must be read in full and completely understood before the installation! 1. General information on the installation and maintenance instructions These instructions

More information

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM 150 150 150 This instruction manual contains proprietary information which is protected by copyright laws. No part of

More information

Angle seat valve with piston actuator VZXA-...-K

Angle seat valve with piston actuator VZXA-...-K Angle seat valve with piston actuator VZXA-...-K Festo AG & Co. KG Postfach 73726 Esslingen Germany +49 711 347-0 www.festo.com 3 Further information Accessories www.festo.com/catalogue Spare parts www.festo.com/spareparts

More information

DIAPHRAGM LIQUID PUMP NF 1.30

DIAPHRAGM LIQUID PUMP NF 1.30 DIAPHRAGM LIQUID PUMP NF 1.30 NF 1.30 KT DCG 12V Supply voltage [Ch. 4] DCG KT / TT [Ch. 4] 1.30 NF - / PMLxxxx / PLxxxx [Ch. 1] Operating and Installation Instructions Read and observe these Operating

More information

Installation and Operational Instructions for ROBATIC -clutch Types _.0 and _.0 Sizes 3 7

Installation and Operational Instructions for ROBATIC -clutch Types _.0 and _.0 Sizes 3 7 Please read these Installation and Operational Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunction or to clutch failure, resulting in damage to other

More information

Diaphragm-Gas Sampling Pumps

Diaphragm-Gas Sampling Pumps Diaphragm-Gas Sampling Pumps N 143 ANE N 143 ATE Operating and Installation Instructions Read and observe these Operating and Installation Instructions! N 186.1.2 ANE N 186.1.2 ATE KNF Neuberger GmbH Alter

More information

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps UNPK04DC Pressure UNPK04DCB Pressure UNPK04DC Vacuum UNPK04DCB Vacuum KNF Neuberger, Inc 2 Black Forest Rd Trenton, NJ

More information

Operating Instructions

Operating Instructions Operating Instructions Quadax Series Butterfly Valves (with actuator) Version September 2009 müller co-ax ag Gottfried-Müller-Str. 1 74670 Forchtenberg Germany Tel. +49 7947 828-0 Fax +49 7947 828-11 E-Mail

More information

Angle seat valve with piston actuator VZXA-...-K

Angle seat valve with piston actuator VZXA-...-K Angle seat valve with piston actuator VZXA-...-K Instructions Operating (Translation of the original instructions) Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany +49 711 347-0 www.festo.com

More information

Installation and Operating Instruction for Brake Caliper HW 150 HFA and HW 180 HFA E e

Installation and Operating Instruction for Brake Caliper HW 150 HFA and HW 180 HFA E e Installation and Operating Instruction for Brake Caliper HW 150 HFA and HW 180 HFA E 09.736e Schaberweg 30-38 Phone +49 6172 275-0 61348 Bad Homburg Fax +49 6172 275-275 Germany www.ringspann.com info@ringspann.com

More information

Starting up hydraulic systems

Starting up hydraulic systems General / Installation A hydraulic system that operates economically, safely, and trouble-free requires careful planning, as well as proper installation and start-up. Conscientious maintenance has a considerable

More information

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be fully read and understood 2 SAFETY Please also read through these notes carefully. 2.1 General potential danger due to: a. Failure to observe the instructions

More information

Micro Diaphragm Gas Sampling Pumps

Micro Diaphragm Gas Sampling Pumps Operating and Installation Instructions Micro Diaphragm Gas Sampling Pumps Type range: NMP830K_DC-M HP NMP830.1.2K_DC-M HP NMP830K_DC-B HP NMP830.1.2K_DC-B HP NMP830K_DC-B4 HP NMP830.1.2K_DC-B4 HP You

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions contain

More information

Angle seat valve with diaphragm actuator VZXA-...-M

Angle seat valve with diaphragm actuator VZXA-...-M Angle seat valve with diaphragm actuator VZXA-...-M Instructions Operating (Translation of the original instructions) Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany +49 711 347-0 www.festo.com

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating Instructions... 2 2 Authorized use...

More information

Installation and commissioning of Settima screw pumps. Type GR** SMT** 3-screw screw pumps. a. Medium:

Installation and commissioning of Settima screw pumps. Type GR** SMT** 3-screw screw pumps. a. Medium: Settima screw a. Medium: HL oil conforming to DIN 51524 Parts 2 and 3 Special media such as: HFA min 5% oil HFB min 40% oil HFC max. 35-55% water HFDR high-viscosity lubricants SKYDROL, MIL-H may also

More information

Storage, operating and maintenance instructions for AZ plug valves and Standard valves

Storage, operating and maintenance instructions for AZ plug valves and Standard valves ARMATUREN Plug - Valves metallic with PTFE Sleeve 2-7 way Storage, operating and maintenance instructions for AZ plug valves and Standard valves Plug - Valves FEP/PFA - lined, 2-3 way Butterfly - Valves

More information

IMPORTANT SAFETY NOTICE

IMPORTANT SAFETY NOTICE IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will minimize your risk of injury. ITT Goulds

More information

A408 GB. Pneumatic oil and diesel pumps 1:1

A408 GB. Pneumatic oil and diesel pumps 1:1 03 594 A408 GB Pneumatic oil and diesel pumps 1:1 G Operating instructions for Pneumatic oil and diesel pump 1:1 Contents 1. General details 2 1.1 Intended use 2 1.2 Design and functional description 2

More information

TSCHAN - TORMAX VSG. Installation and Operation Manual TSCHAN Highly flexible shaft coupling BAWE 009-GBR-0 05/2004

TSCHAN - TORMAX VSG. Installation and Operation Manual TSCHAN Highly flexible shaft coupling BAWE 009-GBR-0 05/2004 BAWE 009-GBR-0 05/2004 Installation and Operation Manual TSCHAN Highly flexible shaft coupling TSCHAN - TORMAX VSG TSCHAN GmbH Zweibruecker Strasse 104 D-66538 Neunkirchen-Saar Telephone: +49(0) 6821 866

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Industrial Process Installation, Operation, and Maintenance Manual Cam-Tite Ball Valve Table of Contents Table of Contents Introduction and Safety...2 Safety message levels...2 User health and safety...2

More information

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE 2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE For Diaphragm Dosing Pumps FEM 1.02_.55 / FEM 1.09_.55 Controller board package, without pump: ID 160536 Operating and Installation Manual It is important to

More information

Operating manual. Custom made gearboxes

Operating manual. Custom made gearboxes Operating manual Custom made gearboxes DSS-Nr. 100389549 DSS-Rev. 001 Datum 16.01.2018 Contents Contents 1 General information 3 1.1 Using the operating manual 3 1.2 Warnings in this operating manual 4

More information

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z INSTRUCTION MANUAL I/P Converter DSG BXXY3Z DSG BXXY4Z Revision 2.0 3.626 016136 en Page 1/15 Should you have any questions concerning the I/P converter, please contact the Service Department of the Product

More information

FLENDER ZAPEX couplings. Type ZWT. Operating instructions BA 3505 EN 10/2011. FLENDER couplings

FLENDER ZAPEX couplings. Type ZWT. Operating instructions BA 3505 EN 10/2011. FLENDER couplings FLENDER ZAPEX couplings Type ZWT Operating instructions FLENDER couplings FLENDER ZAPEX couplings Type ZWT Operating instructions Translation of the original operating instructions Technical data Notes

More information

Operating & Maintenance Manual For Steam Conditioning Valve

Operating & Maintenance Manual For Steam Conditioning Valve For Steam Conditioning Valve 1 Table of Contents 1.0 Introduction 3 2.0 Product description 3 3.0 Safety Instruction 4 4.0 Installation and Commissioning 5 5.0 Valve Disassembly 6 6.0 Maintenance 6 7.0

More information

PNEUMATIC PUMP Series

PNEUMATIC PUMP Series PNEUMATIC PUMP Series 3103... User and Maintenance Manual Original text translation TABLE OF CONTENTS 1. INTRODUCTION 2. GENERAL DESCRIPTION 3. PRODUCT-MACHINE IDENTIFICATION 4. TECHNICAL CHARACTERISTICS

More information

Original Operating Instructions

Original Operating Instructions Edition: 2.8.2013 BA 887-EN Original Operating Instructions C-DLR 301 Compressor C-Serie C-Series Klaue Claw Table of contents Table of contents 1 Foreword...................................................................

More information

Diaphragm Vacuum Pump

Diaphragm Vacuum Pump Diaphragm Vacuum Pump with Diaphragm Stabilization System Operating Instructions Read and observe these Operating Instructions! N 920 AP.18 N 920 AP.29.18 N 920 KT.29.18 KNF Neuberger GmbH Alter Weg 3

More information

RA / Internal Gear Pump Model GP3, Series 3X Fixed Displacement. Typical application:

RA / Internal Gear Pump Model GP3, Series 3X Fixed Displacement. Typical application: Sizes 20 to 32 Internal Gear Pump Model GP3, Series 3X Fixed Displacement up to 5076 PSI 1.25 to 1.98 in 3 (350 bar) (20.6 to 32.5 cm 3 ) RA 10 234/07.97 Characteristics: Peak pressure of up to 5.076 PSI

More information

GF Spin Finish Pump. Translation of the Original Operating Instruction. Edition:

GF Spin Finish Pump. Translation of the Original Operating Instruction. Edition: Translation of the Original Operating Instruction Edition: released: Status: Document no.: Contract no.: V11 01/2018 1-007-3296 Oerlikon Barmag Zweigniederlassung der Oerlikon Textile GmbH & Co. KG Leverkuser

More information

CENTAFLEX-K Assembly and operating instructions 014K S... M EN Rev. 1

CENTAFLEX-K Assembly and operating instructions 014K S... M EN Rev. 1 Assembly and operating instructions Contents 1 General remarks... 5 2 Safety... 6 2.1 Qualification of deployed personnel... 6 2.2 Warning notes... 6 2.2.1 Signal words... 6 2.2.2 Symbols... 7 2.3 Application

More information

Micro Diaphragm Gas Sampling Pumps

Micro Diaphragm Gas Sampling Pumps Operating and Installation Instructions Micro Diaphragm Gas Sampling Pumps Type range: NMP 03 KP DC-B1 NMP 03 KP DC-S NMP 03 KP DC-B3 NMP 03 KP DC-M NMP 03 KP DC-L You have selected a high-quality KNF

More information

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080 CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080 STI S.r.l has taken every care in collecting and verifying the documentation contained in this Instruction Manual. The information herein contained are

More information

X.. Series Helical and Bevel-Helical Gear Units

X.. Series Helical and Bevel-Helical Gear Units SEW-EURODRIVE Easy Guide Industrial Gear Units X.. Series Helical and Bevel-Helical Gear Units Edition 05/2018 24803731/ EN 2/16 Gear unit structure 1 Safety notes 2 Gear unit designs 3 Mounting positions

More information

RA / Internal Gear Pump Model GP2, Series 2X Fixed Displacement. Typical application:

RA / Internal Gear Pump Model GP2, Series 2X Fixed Displacement. Typical application: Sizes 6.3 to 16 Internal Gear Pump Model GP2, Series 2X Fixed Displacement up to 576 PSI.397 to.98 in 3 (35 bar) (6.5 to 16 cm 3 ) RA 1 23/6.97 RA 1 23/6.97 Characteristics: Peak pressure of up to 576

More information

EPS 16 ATEX 1121 X, IECEx EPS X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx. Operating Instructions

EPS 16 ATEX 1121 X, IECEx EPS X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx. Operating Instructions , IECEx EPS 16.0053X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx Device with II 2G/D Ex approval Geräte mit II 2G/D Ex Zulassung Appareils avec mode de protection II 2G/D Ex

More information

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

Air Operated Diaphragm Pumps Operating and Maintenance Instructions Product & Chemical Disclaimer The user must take responsibility in the selection of the products materials of construction. Empire Pumps Ltd will act in an advisory role and offer recommendations; however,

More information

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3 EN Operating manual Motorised zone valve Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3 This manual ensures safe and efficient use of the 3PV2 or 3PV8 force-actuated three-way valve with spring-loaded return

More information

Diaphragm Vacuum Pumps and Compressors

Diaphragm Vacuum Pumps and Compressors Diaphragm Vacuum Pumps and Compressors N 035 ANE N 035 AN.9 E N 035 ATE N 035 AVE N 035 AV.9 E N 035 SNE N 035 STE N 035 ST.9 E N 035 SVE Operating and Installation Instructions Read and observe these

More information

Operating instructions

Operating instructions Operating instructions Digital tank contents indicator DTA 10 DTA 10 DTA 10 0 4.0 m fuel oil 0 3.5 m water Read instructions before using device! Observe all safety information! Keep instructions for future

More information

FF 20 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS

FF 20 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS FF 20 INSTALLATION INSTRUCTIONS DIAPHRAGM PUMP FF 20 DCB-4 FF 20 DC-M Before operating the pump and the accessories, please read the Installation Instructions and safety precautions. Installation Instructions

More information

Owners Manual: - Pumps

Owners Manual: - Pumps Owners Manual: - Pumps GENERAL SAFETY RULES 1. The products mentioned in this manual are specially designed for the pre-filtering and re-circulation of water in swimming pools and spas. 2. They are designed

More information

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Compact System NRGS 11-2 NRGS Original Installation Instructions English Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive

More information

Internal Gear Pumps Installation Manual

Internal Gear Pumps Installation Manual Internal Gear Pumps Installation Manual MEDIUM HEAVY DUTY SERIES SIZE 2 PGI100-2-005 PGI100-2-006 PGI100-2-008 PGI100-2-011 PGI100-2-013 PGI100-2-016 PGI100-2-019 PGI100-2-022 PGI100-2-025 PGI100 MEDIUM

More information

CENTAX-TEST Assembly and operating instructions 053C GB3. M EN Rev. 1

CENTAX-TEST Assembly and operating instructions 053C GB3. M EN Rev. 1 Assembly and operating instructions Contents 1 General remarks... 5 2 Safety... 6 2.1 Safety remarks... 6 2.1.1 Signal words... 6 2.1.2 Pictograms... 7 2.2 Qualification of deployed personnel... 7 2.3

More information

Internal Gear Pumps. Series QX. Reference: 100-P E-10 1/32. Issue:

Internal Gear Pumps. Series QX. Reference: 100-P E-10 1/32. Issue: Internal Gear Pumps eries QX Reference: -P-000021-E-10 Issue: 11.2011 1/32 2/32 Contents Page 1 General... 5 1.1 Product description... 5 1.2 Advantages... 5 2 Technical data... 5 2.1 General (deviating

More information

Instruction manual. Installation requirements. Power Take-Off. Pump mounting: Spline shaft DIN 5462 / ISO 14. Mounting flange ISO 7653-D.

Instruction manual. Installation requirements. Power Take-Off. Pump mounting: Spline shaft DIN 5462 / ISO 14. Mounting flange ISO 7653-D. GB PUMP SCPD 76/76 DIN Instruction manual Thank you for choosing Sunfab You have chosen SCPD 76/76, a dual flow pump with the highest displacement-to-size-ratio on the market. It can effectively be directly

More information

Dry installed pump type LANDY BTP.

Dry installed pump type LANDY BTP. OPERATION & MAINTENANCE MANUAL Dry installed pump type LANDY BTP. Landustrie Sneek BV Pieter Zeemanstraat 6 Tel. 0031 515-486888 P.O. BOX 199 Fax. 0031 515-412398 NL-8600 AD Sneek info@landustrie.nl The

More information

Installation manual wall-mounted distributor

Installation manual wall-mounted distributor EN Installation manual wall-mounted distributor EN 60003233 Issue 11.2016 2016-14-11 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2

More information

Type 3360, Service Manual. Serviceanleitung Service Manuel

Type 3360, Service Manual. Serviceanleitung Service Manuel Electromotive control valve Elektromotorisches Regelventil Vanne de régulation électromotorisée Service Manual Serviceanleitung Service Manuel We reserve the right to make technical changes without notice.

More information

PUMP SCPD 56/26 DIN BY-PASS

PUMP SCPD 56/26 DIN BY-PASS GB INSTRUCTION MANUAL THANK YOU FOR CHOOSING SUNFAB You have chosen SCPD 56/26 DIN, a dual flow pump with differentiated flow suitable for combination vehicles with high power take off ratio and high output

More information

High Pressure Internal Gear Pumps Series QX

High Pressure Internal Gear Pumps Series QX High Pressure Internal Gear Pumps Series QX motion and progress 1 / 32 Classification: 410.10..00 Reference: -P -000021 -E -06 / 05.05 Contents 1 General 1.1 Product description 3 1.2 Advantages 3 2 Technical

More information

Rolli D6/5A. Operating Instructions HORN GMBH & CO. KG. Product Description. Safety Indications. Mounting. Commissioning.

Rolli D6/5A. Operating Instructions HORN GMBH & CO. KG. Product Description. Safety Indications. Mounting. Commissioning. Declaration of Conformity Operating Instructions Rolli D6/5A 440209101-A 03/2004 Subject to technical alterations. Text and design copyrighted. Reprinting and copying, even if excerpts, only with written

More information

Operating Instructions: Hand-operated, PTFE-lined butterfly valves, Series 22/23

Operating Instructions: Hand-operated, PTFE-lined butterfly valves, Series 22/23 0 Introduction These instructions are intended to assist users of BRAY PTFE-lined butterfly valves, Series 22/23 in fitting, operating and servicing valves. Risks may arise and the manufacturer's warranty

More information

Operating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV Page 2. Danfoss VI.IX.A1.02 1

Operating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV   Page 2. Danfoss VI.IX.A1.02 1 Operating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV www.danfoss.com Page 2 Danfoss 2016.06 VI.IX.A1.02 1 Table of Contents: 1. OVERVIEW... 3 2. GENERAL... 3 2.1 Safety...3 2.2 Proper use...4

More information

Wilo-Control SC-Fire Jockey

Wilo-Control SC-Fire Jockey Pioneering for You Wilo-Control SC-Fire Jockey de en fr Einbau- und Betriebsanleitung Installation and operating instructions Notice de montage et de mise en service nl Inbouw- en bedieningsvoorschriften

More information

DIAPHRAGM LIQUID PUMP NF 1.25

DIAPHRAGM LIQUID PUMP NF 1.25 DIAPHRAGM LIQUID PUMP NF 1.25 NF 1.25 RP DC 12V Supply voltage [Ch. 4] DC / DCB-4A RP / RT [Ch. 4] 1.25 NF / UNF - / PMLxxxx / PLxxxx [Ch. 1] Operating and Installation Instructions Read and observe these

More information

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) User Guide Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) version 04/2013 Content General Information 3 Warning 3 Scope of Supply 3 Overview 3 General safety details 4 Intended use 4

More information

Operating instructions Rotary actuators M135 M140 M150 M180. June 2012 / / EN

Operating instructions Rotary actuators M135 M140 M150 M180. June 2012 / / EN Operating instructions Rotary actuators M135 M140 M150 M180 June 2012 / 118614 / EN General information General information Proof of amendment Copyright Subject to alterations Manufacturer Version Date

More information

Quick-Disconnect Coupling one-hand operation Push Pull ND 5, connecting thread G 1/4,max. operating pressure 500 bar

Quick-Disconnect Coupling one-hand operation Push Pull ND 5, connecting thread G 1/4,max. operating pressure 500 bar Issue 12-2013 Quick-Disconnect Coupling one-hand operation Push Pull ND 5, connecting thread G 1/4,max. operating pressure 500 bar Figure 1: Coupling complete Figure 4: Coded coupling, complete Table of

More information

Installation and Operation Manual

Installation and Operation Manual Industrial Process Installation and Operation Manual Advantage Actuator 2.0 Table of Contents Table of Contents Introduction and Safety...2 Safety message levels...2 User health and safety...2 Transportation

More information