ComTank Unit Installation Sheet. Version 1.0.0

Size: px
Start display at page:

Download "ComTank Unit Installation Sheet. Version 1.0.0"

Transcription

1 ComTank Unit Installation Sheet Version 1.0.0

2 Product Identification Manual Title ComTank Unit Installation Sheet Publication Date Wednesday, 4 December 2013 Application Compac ComTank Power supply VAC; 50 Hz; 1 Amp +/- 10% Related Manuals ComTank Pump Installation Sheet C4000 Master Manual CompacOnline User Guide (CompacOnline capable ComTank) USB Key User Guide (USB equipped ComTank) Master Installation Sheets Validity Compac Industries Limited reserves the right to revise or change product specifications at any time. This publication describes the state of the ComTank and related products at the time of publication and may not reflect the product at all times in the past or in the future. Manufacturer Contact Details The Compac ComTank is designed and manufactured by: Compac Industries Limited 52 Walls Road, Penrose, Auckland 1061, New Zealand P.O. Box , Penrose, Auckland 1641, New Zealand Phone: Fax: Copyright 2013 Compac Industries Limited, All Rights Reserved

3 Contents Product Identification... ii Document Control Information... 4 Introduction... 5 Safety... 6 Installation... 7 Tools Required... 7 Pre-installation Checks... 8 Site Preparation... 8 Mounting Preparation... 9 Electrical Preparation Precautions if Using Generator Power Electrical Connection Wiring Diagram Control Unit Modem Connections Powering up Checking Pump Prices Power on Tests Checking Authorisation Methods Checking Card Reader Checking USB Module Checking Transactions are Uploaded Finishing Up Spare Parts Installation Checklist Page 3

4 Document Control Information Document Control Information Document Information and Revision History Document Details: File Name and Location: Current Revision Author(s): ComTank Installation Sheet G:\Masters\Installation Sheets\ComTank Installation Sheet R Lacey Authorised By: Tim Mayson Release Date: 04/11/2013 Version Date Author(s) Revision Notes Distribution Name Indicator Location Compac Industries Ltd. Page 4

5 Introduction Introduction The Compac ComTank is a diesel fuel dispenser authorisation and reporting device designed to be flush-fitted to a wall, fuel tank or in the side of a shipping container. It is designed to be connected to Compac Master series pumps. ComTank specific Master series pumps with remote displays and nozzle holders are available to allow users to fully customise the location of authorisation panel, pump display, hose outlet and nozzle holder to suit their site requirements. Features include: Effective solution for tanks and pumps that need to be securely locked Ideal for portable installations Control interface for Master mechanical components Remote mountable nozzle holders Commercial or Retail display, with the option of remote mountable additional display Single or Dual Hose Choice of stainless steel panels (for corrosive situations) or gold passivated mild steel Authorisation Options PIN pad Electronic Tag (HID, itrack or CWID - Compac Wireless Identifier- key tag or nozzle tag) Swipe card Transaction Downloading Options USB stick CompacOnline Tank Gauging Options Veeder-Root Fafnir Vega Franklin Options may vary depending on application. These installation instructions refer specifically to the ComTank authorisation unit and related hardware. For detailed instructions on the installation, setup and calibration of pumps and for the operation of the authorisation and reporting systems, refer to their specific manual. Compac Industries Ltd. Page 5

6 Safety Safety You must adhere to the following safety precautions at all times when working on this unit. Failure to observe these safety precautions could result in electrical or mechanical damage to the unit or injury or death to yourself or bystanders. Make sure that you read and understand all safety precautions before installing, servicing or operating this unit. Failure to follow safety instructions may invalidate any warranty. Mechanical Safety Observe the following mechanical precautions: During installation, take care that the unit is well supported and cannot fall over. required. Take care with handling sharp edges, wear gloves where Make sure that the service area is thoroughly clean when servicing. Dust and dirt entering the components may reduce the life span of the components and can affect operation. Electrical Safety Observe the following electrical precautions: Always turn off the power to the unit before commencing work on any wiring. Never touch wiring or components inside the high voltage area with the power on. Be aware that capacitors and back up batteries may power the unit even after mains power is removed. Always turn off the power to the unit at the mains switch before removing or replacing software or memory ICs. Always take basic anti-static precautions when working on the electronics, i.e., wearing a wristband with an earth strap. Environmental Safety Observe the following environmental precautions: Take care that you clean up after working on the unit. Remove and carefully dispose of any waste. Any spills must be cleaned up and disposed of in an approved manner. Any spillage of fuel must be handled to minimise the risk of fire or explosion. Major spills must be reported to the local environmental authorities. Site Safety Observe the following precautions when on site: Personal safety is the responsibility of the site manager and technician. Personal protective equipment appropriate to the situation is to be worn and if required, the working area appropriately cordoned off with cones, tape and/or barriers. When working on or near flammable goods areas take all precautions to avoid sources of ignition. These instructions are intended as a guide only. It is the responsibility of the technician and the site manager to manage safety in accordance with local regulations and best safe site practice. Compac Industries Ltd. Page 6

7 Installation Installation You must be properly qualified, trained and authorised to install this unit. Ensure you are qualified to perform each of the operations described. Security To help prevent unauthorised tampering, it is recommended that tamper resistant fasteners be used and that all wiring outside the cabinet is enclosed. Tools Required Tools Power Tools Electrical Tools Diagnostic Equipment Safety Equipment Other Equipment It is expected that installers will carry a comprehensive tool kit including: Metric and imperial spanners Metric and imperial socket set Metric and imperial allen keys Torx and security torx keys Phillips, pozidriv and flat blade screwdrivers Electric drill (observe site safety protocols when using power tools) Wire cutters Wire stripper Crimping tool EPROM extractor Multimeter Earthing wrist strap Remote pump display to enable easier pump setup. Laptop with fully charged battery and wireless modem LAN cable Fully charged cell phone Test cards and/or authorisation keys High visibility vest or jacket Personal protective equipment (PPE) Boots, gloves, goggles, hearing protection, hard hat etc. Cones, barriers, tape to secure your working area Step ladder Torch Cable ties Cleaning spray and clean cloths The above list is a suggested minimum. It is recommended that you read the manual thoroughly and include any other equipment that may assist you in completing the job safely and quickly. Compac Industries Ltd. Page 7

8 Pre-installation Checks Pre-installation Checks Transit Damage Tampering Vibration Site Issues Once the unit is received on site, inspect the unit for the following: Shipping damage to housing, display or any other equipment. Water damage to components Report any damage to the transport company and to the help desk. Take photographs if required. Inspect for: Evidence of tampering with the unit especially card reader or unauthorised wiring. Report any concerns to the help desk. Take photographs if required. Inspect terminals, plugs and IC chips to check they are securely in place and have not loosened due to vibration. Check that all wiring and pipework has been installed correctly and is undamaged. Report issues to site manager. Inappropriate installation may void the warranty. If uncertain, contact your Compac agent for advice. Site Preparation Refer to the Site Audit document if supplied. To ensure maximum operating life, care should be taken when installing the ComTank components. Considerations should include: The card reader and PIN pad should face away from the prevailing wind especially in dusty or wet areas. In areas experiencing extremes of weather (heat, cold, wind, rain, salt spray etc.) consideration should be given to installing additional shelter. The rear of the displays and the electrical components must be protected from dust, water or high humidity. Any protective surrounds that are constructed must also allow for adequate cooling. Inappropriate installation may void the warranty. If uncertain, contact your Compac agent for advice. Compac Industries Ltd. Page 8

9 Mounting Preparation Mounting Preparation The ComTank unit needs to be mounted to a flat, steel plate prepared with a cut-out and fastener holes as per drawing below. A steel template marked with the appropriate dimensions is available as an option from Compac. Holes are drilled to clear M6 (6 mm diameter) studs. Ensure your mounting plate is thin enough to allow you to put the washers and nuts on the end of the 20mm long studs. The plate the ComTank is mounted on should be rust protected if it is not made from stainless steel. Ensure there is sufficient access to allow the installer and service people to comfortably remove the cover from the rear of the unit and perform service work. A minimum clearance of 850 mm is recommended. Figure 1 ComTank Panel Cutout. Note: Do not cut to outer lines. If installing ComTank pumps as part of the installation, refer to the ComTank Pump Installation Sheet for pump, display and nozzle holder mounting instructions. Compac Industries Ltd. Page 9

10 Precautions if Using Generator Power Electrical Preparation The ComTank control unit requires its own wiring from the power supply. Power and communication cables must meet or exceed local regulation requirements. If no local regulations exist, we recommend as a minimum: Power: 3 core 2.5 mm 2 Steel Wire Armour (SWA) cable Comms (standard current loop): 2 core 1.5 mm 2 Steel Wire Armour (SWA) cable The length of the communications cable must not exceed 100 metres. Precautions if Using Generator Power The power output from onsite generators can cause power spikes that may damage electrical components within the cabinet. When connecting to sites powered by generators, please take the following precautions: Install a power conditioner. Although generators are fitted with power regulators, most are not filtered sufficiently for powering sensitive electrical components. We recommend installing a commercial power conditioner and/or UPS between the generator and the unit. Starting up. Before starting a generator, make sure the power to the unit is turned off. Start the generator, let the generator reach stable operating speed and wait 30 seconds before reconnecting the power to the unit. For units where the generator starts and stops on demand, install a delay timer or PLC to automatically isolate the unit until the operating speed and consistent power output is achieved. Isolate the unit before shutting down the generator. Compac Industries Ltd. Page 10

11 Electrical Connection Electrical Connection Cable requirements 230V Mains Pump Comms ComTank control unit power: 3 Core Steel Wire Armour Cable 2.5mm Volts, 10A, 50 Hz Pump comms (standard current loop): 2 core Steel Wire Armour (SWA). Pump comms (RS485): 3 core Steel Wire Armour (SWA). Refer to the wiring diagram on page 12. Connect the incoming mains as follows: All terminals marked N are common. All terminals marked P are common. Connect the Earth to the busbar at the bottom of the cabinet. Connect the pump comms cable(s) to the terminals on the DIN rail. Nozzle switches Tank Gauging (option) If pumps do not communicate on start up, swap the wires over. The nozzle switch cable is pre-wired to the pump. Plug into the socket(s) on the nozzle switch(es) making sure the correct cable is connected to the nozzle.. Coil and neatly cable tie any excess cable out of the way. Tank gauging if fitted should be wired to the Tx, Rx and G terminals. If tank level does not appear on your administration program after initial setup swap the Tx and Rx wires. All wires entering the unit should be glanded and secured to prevent stressing the terminals. Compac Industries Ltd. Page 11

12 Wiring Diagram Wiring Diagram Compac Industries Ltd. Page 12

13 Modem Connections Modem Connections Cellular Modem The cellular modem (if fitted) is prewired and only requires a SIM card to be fitted. To fit the SIM card 1. Depress the small yellow button on the top of the cell modem. 2. Remove the black plastic SIM card-holder. 3. Insert the SIM card. 4. Refit the SIM card holder. There is a red diagnostic LED on the end of the Cell modem which will initially be permanently on but will start to flash when the Cell Modem is connected to the Network. Compac Industries Ltd. Page 13

14 Powering up Modem Connections Powering up When all connections have been made and checked. Install the protective perspex cover over the terminals. Where regulations require, a registered electrician must check and approve connections. Connect power to the unit and turn on the circuit breaker. Check that the PIN pad screen (if fitted) is illuminated and boots up. If the unit is controlled via the internet, contact your help desk and confirm that the unit is on line. Confirm the on-line pump pricing. Checking Pump Prices Pricing via USB Module Pricing via Internet The following is a brief overview for technicians who are experienced in the installation and setup of similar equipment. Specific instructions for each option are either supplied or available from Compac. The ComTank unit controls the pricing at the pumps. In most circumstances the pricing information is sent to the unit either via a USB key or via the internet using Netbase or CompacOnline. Start up your laptop, insert the Compac USB key and open the Price file. Check the price is correct. If not, change it and save. Insert the key into the USB module, select Set Price and confirm. Turn off the unit and the pumps, connect the pump communications wires and repower. Check that the pricing on each hose is correct. Confirm that the unit is on line and that the help desk has installed all updates. Write down the on-line price(s). Turn off the unit and the pumps, connect the pump communications wires and repower. Check that the price on each hose matches the on-line price. Compac Industries Ltd. Page 14

15 Power on Tests Checking Authorisation Methods Power on Tests Depending on the setup of the unit, you will need to perform a number of tests. Checking Authorisation Methods Units can be authorised in a wide variety of ways: No authorisation required. Unit just records transactions. PIN pad authorisation. Customer enters a PIN number and/or odometer reading to authorise pumps. Fuel card authorisation. Customer swipes their issued fuel card. A PIN number and/or odometer reading may or may not be requested. Credit card authorisation. Customer swipes credit card to authorise pumps. HID or CWID key authorisation. Customer passes a coded RFI key in front of a reader. CWID nozzle authorisation. A CWID key is attached to the vehicle filler and a reader is attached to the pump nozzle. Inserting the nozzle into the filler authorises the pump. itrack reader authorisation. A unit attached to the vehicle authorises the pumps as it pulls into the forecourt. All authorisation methods set up on the unit will need to be tested. Checking Card Reader Check the card reader to see if it reads approved cards. Swipe a test card and check that a transaction can be made. The card is inserted with the stripe to the top and on the right hand side. Do this for all types of approved cards. Checking USB Module The USB module allows downloading of pricing updates and authorised card numbers and uploading of transactions. Perform a test transaction and print a receipt for each hose. Insert the Compac Supplied USB key into the reader. At the prompt, choose Get Transactions. Wait while the transactions are uploaded then remove key. Insert the Key into your laptop, open the Transactions folder and see if you can see the recorded transactions. Check that the receipt information matches the transaction information. Compac Industries Ltd. Page 15

16 Checking Transactions are Uploaded Finishing Up Checking Transactions are Uploaded Contact the your Netbase or CompacOnline administrator and check that your test transactions and any customer transactions that have taken place have been recorded correctly on Netbase or CompacOnline. For USB equipped units, download your test transactions and check that the information recorded matches the information on the receipts. Finishing Up When you are confident the site is trading correctly, complete the installation checklist. If you do not have one, a copy is attached at the end of these instructions. Fax the installation sheet to Compac as soon as you can. Replace and fasten the cover on the back of the ComTank unit and any pump covers that may have been removed. Remove all tools, clean the unit, pick up all debris and tidy the surrounding area. Remove any barriers or cones. Contact help desk and tell them that you are about to leave the site. Spare Parts Order spare parts from your Compac agent. You must quote the model and serial number of the unit. Compac Industries Ltd. Page 16

17 Installation Checklist Checking Transactions are Uploaded Installation Checklist Version ComTank. Site number and name: Date: Installer name and phone number: Serial number: When a new unit is being installed use the following checklist to make sure the unit is fully operational. Check each box or write N/A where not applicable. Refer to the relevant installation manual for procedures. Mechanical Checks Check unit is undamaged and has not been tampered with. Yes No Is the unit in a sheltered position and facing away from the prevailing wind and rain? Check all panels are securely fastened using tamper-proof fastenings where supplied. Check that all cable entries to unit are through glands and unused glands are sealed. Power on Checks Check that the CE board, FMS board, pinpad, printer, cardreader, router and modem all power up. Yes No Check pumps are re-priced to the current fuel price. Check that different fuels are correctly priced on all hoses. Transaction Checks Complete transaction using white card/cwid/hid/pin authorisation methods Yes No Check that all hoses can be selected and authorised by the unit. USB Module Checks (where fitted) Check the supplied USB key is recognised by the unit. Yes No Select "Get Transactions" and check that transactions are uploaded to the USB key. Compac Industries Ltd. Page 17

18 Checking Transactions are Uploaded Installation Checklist CompacOnline Checks (when connected) Check the site appears on CompacOnline. Yes No Check that transactions have been recorded on CompacOnline. Tank Gauging Checks (where fitted) Check that tanks are set up in CompacOnline and that correct levels are being reported. Yes No Check that the correct products are assigned to the correct tanks. Customer Training Check site attendants understand refuelling procedures. Yes No Check that site administrators understand how to obtain transactions and administer cards. Final Checks Yes No Notes Ensure all cables are plugged back in after remote accessing. Tidy up all rubbish and clean the exterior of the unit before leaving. If one or more of these tests fail, contact the Compac help desk or your service centre so the problem can be logged and parts issued if required. To validate warranty and receive future help desk assistance please fax both sides of this form to: or post to: Compac Industries Ltd, PO Box Penrose, Auckland 1642, New Zealand. Report any damage immediately to Compac Industries on: Any site safety issues should be reported immediately to the site manager. Compac Industries Ltd. Page 18

Communicator Installation Sheet. Version 1.0.1

Communicator Installation Sheet. Version 1.0.1 Communicator Installation Sheet Version 1.0.1 Product Identification Product Identification Manual Title Communicator Installation Sheet Publication Date Wednesday, 5 October 2011 Application Compac Communicator

More information

ComFutra Installation Sheet. Version 1.0.0

ComFutra Installation Sheet. Version 1.0.0 ComFutra Installation Sheet Version 1.0.0 Product Identification Manual Title ComFutra Installation Sheet Publication Date Wednesday, 5 October 2011 Application Compac ComFutra - All applications Power

More information

OPT SCR200 Installation Manual Version No: Model: OPT Mark 2 SCR200 Date: 20/03/2018

OPT SCR200 Installation Manual Version No: Model: OPT Mark 2 SCR200 Date: 20/03/2018 OPT SCR200 Installation Manual Version No: 1.0.1 Model: OPT Mark 2 SCR200 Date: 20/03/2018 Compac Industries Ltd. 52 Walls Road. Penrose. Auckland 1061. New Zealand. PO Box 12 417. Penrose. Auckland 1642.

More information

COMPAC PRODUCT RANGE

COMPAC PRODUCT RANGE COMPAC PRODUCT RANGE Backed by over 30 years experience manufacturing fuel pumps and dispensers and using the latest in electronic and software technology Compac has designed and developed a range of intelligent

More information

Card King Installation Sheet

Card King Installation Sheet Card King Installation Sheet Version 1.0.4 Compac Industries Ltd. 52 Walls Road. Penrose. Auckland 1061. New Zealand. PO Box 12 417. Penrose. Auckland 1642. New Zealand. Tel: +64 9 579 2094 Fax: +64 9

More information

Card King Installation and Service Manual

Card King Installation and Service Manual Card King Installation and Service Manual Version 1.0.4 Conditions of Use Conditions of Use Read this manual completely before working on or making adjustments to the Compac equipment. Compac Industries

More information

Installation Manual Version No 1.0.4

Installation Manual Version No 1.0.4 Installation Manual Version No 1.0.4 Model: Comfill Date: 31 st May 2018 Conditions of Use Conditions of Use Read this manual completely before working on, or making adjustments to, the Compac equipment

More information

Pumps & Dispensers MASTER LASER PUMP FEATURES»»»»»»»» PUMP FEATURES»»»»»»»»

Pumps & Dispensers MASTER LASER PUMP FEATURES»»»»»»»» PUMP FEATURES»»»»»»»» COMPAC PRODUCT RANGE State of the art manufacturing computer systems and software has allowed Compac to design and develop a range of intelligent integrated refuelling systems Pumps & Dispensers MASTER

More information

Installation and Setup Instructions

Installation and Setup Instructions Installation and Setup Instructions Model: Master Version: MMR80-40S Date of issue: 22 May 2009 Compac Industries Ltd P O Box 12-417 Penrose Auckland New Zealand Ph 64 9 5792 094 Fax 64 9 5790 635 www.compac.co.nz

More information

Master Pumps Installation Manual Version No 1.0.2

Master Pumps Installation Manual Version No 1.0.2 Master Pumps Installation Manual Version No 1.0.2 Model: Master Pumps Date: Friday, 8 December 2017 Conditions of Use Conditions of Use! Read this manual completely before working on, or making adjustments

More information

Installation and Setup Instructions

Installation and Setup Instructions Installation and Setup Instructions Model: Version: Master MR160P Date of issue: 27 January 2015 Compac Industries Ltd. 52 Walls Road. Penrose. Auckland 1061. New Zealand. PO Box 12 417. Penrose. Auckland

More information

L400S, L400S Marine Installation Manual Version No 1.0.5

L400S, L400S Marine Installation Manual Version No 1.0.5 L400S, L400S Marine Installation Manual Version No 1.0.5 Model: L400S, L400S Marine Date: Monday, 11 December 2017 Conditions of Use Conditions of Use! Read this manual completely before working on, or

More information

Installation Guide Rollerdor RD55 Econ Roller Garage Door

Installation Guide Rollerdor RD55 Econ Roller Garage Door Installation Guide Rollerdor RD55 Econ Roller Garage Door 1 Finished door Rollerdor RD55 Econ Roller Garage Door CHECKLIST & COMPONENTS EQUIPMENT REQUIRED 2 x Step ladders or hop ups Spirit level Tape

More information

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference. Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

1100W PORTABLE GENERATOR

1100W PORTABLE GENERATOR 1100W PORTABLE GENERATOR MODEL NO: G1200 PART NO: 8010110 OPERATION & MAINTENANCE INSTRUCTIONS LS0312 INTRODUCTION Thank you for purchasing this CLARKE 1100W Portable Generator. Before attempting to use

More information

SentryGOLD Compact. for Bennett Electronic Dispenser INSTALLATION MANUAL. Fuel Management System

SentryGOLD Compact. for Bennett Electronic Dispenser INSTALLATION MANUAL. Fuel Management System Fuel Management System SentryGOLD Compact for Bennett Electronic Dispenser INSTALLATION MANUAL 2901 Crescent Drive Tallahassee, FL 32301 (850) 878-4585 office (850) 656-8265 fax www.trakeng.com support@trakeng.com

More information

Gas Actuated Valve Supplement

Gas Actuated Valve Supplement Gas Actuated Valve Supplement Product Gas actuated valve Models covered All models fitted to Compac CNG dispensers and Compac Priority Panels Technical parameters Product Maximum inlet pressure Temperature

More information

1200W INVERTER GENERATOR

1200W INVERTER GENERATOR 1200W INVERTER GENERATOR MODEL NO: IG1200 PART NO: 8877070 OPERATION & MAINTENANCE INSTRUCTIONS LS0117 INTRODUCTION Thank you for purchasing this CLARKE 1200W Inverter Generator. Before attempting to use

More information

GPS AutoSteer System Installation Manual

GPS AutoSteer System Installation Manual GPS AutoSteer System Installation Manual John Deere Track Supported Models 8295RT 8320RT 8345RT PN: 602-0255-01-A LEGAL DISCLAIMER Note: Read and follow ALL instructions in this manual carefully before

More information

GENERAL INFORMATION. INSTRUCTIONS FOR 500A Lithium Jump Starter

GENERAL INFORMATION. INSTRUCTIONS FOR 500A Lithium Jump Starter INSTRUCTIONS FOR 500A Lithium Jump Starter Stock No.15067 Part No.LJS136 IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS PRODUCT. GENERAL INFORMATION These

More information

CALTRAP INSTALLATION AND OPERATIONS MANUAL

CALTRAP INSTALLATION AND OPERATIONS MANUAL INSTALLATION AND OPERATIONS MANUAL NOTE Please read this entire installation and operations manual before energizing the. Safety Considerations: Installing and servicing capacitor equipment can be hazardous.

More information

AdBlue Master V50 Installation Manual v Model: AdBlue Master Dispensers Date: 15 th November 2018

AdBlue Master V50 Installation Manual v Model: AdBlue Master Dispensers Date: 15 th November 2018 AdBlue Master V50 Installation Manual v.1.0.3 Model: AdBlue Master Dispensers Date: 15 th November 2018 Compac Industries Ltd. 52 Walls Road. Penrose. Auckland 1061. New Zealand. PO Box 12 417. Penrose.

More information

CNG Unloading Post Installation and Service Manual

CNG Unloading Post Installation and Service Manual CNG Unloading Post Installation and Service Manual Version 1.0.0 Compac Industries Ltd. 52 Walls Road. Penrose. Auckland 1061, New Zealand. PO Box 12 417 Penrose. Auckland 1642. New Zealand. Tel: +64 9

More information

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference Please dispose of Packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01 PrintPRO Universal Contents Overview 1 01 02 03 Overview of your extraction system (front) Overview of your extraction system (back) Overview of the Control Panel Safety Instructions 2 01 Important safety

More information

KeContact P20. User manual

KeContact P20. User manual KeContact P20 User manual Comments to this manual In this manual you will find warnings against possible dangerous situations. The used symbols apply to the following meanings:!! WARNING! Indicates a potentially

More information

DIAGNOSTIC TOOL BATTERY

DIAGNOSTIC TOOL BATTERY BATTERY DIAGNOSTIC TOOL 81164 These instructions accompanying the product are the original instructions. This document is part of the product, keep it for the life of the product passing it on to any subsequent

More information

PRIORITY FILL PANEL INSTALLATION AND SERVICE MANUAL Includes Compressor Top Up models

PRIORITY FILL PANEL INSTALLATION AND SERVICE MANUAL Includes Compressor Top Up models PRIORITY FILL PANEL INSTALLATION AND SERVICE MANUAL Includes Compressor Top Up models Version 1.0.2 Compac Industries Ltd. 52 Walls Road. Penrose. Auckland 1061. New Zealand. PO Box 12 417. Penrose. Auckland

More information

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230 230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230 PART NO: 7160050 OPERATION & MAINTENANCE INSTRUCTIONS GC0816 INTRODUCTION Thank you for purchasing this CLARKE Pump. The DFTP230 pump is a self-priming rotary

More information

ORIGINAL INSTRUCTIONS

ORIGINAL INSTRUCTIONS OPERATION & MAINTENANCE INSTRUCTIONS CBB200 Shown here BUFFER/POLISHER MODEL NO: CBB150, CBB200 PART NO: 6500485, 6500490 ORIGINAL INSTRUCTIONS LS0818 - ISS 1 INTRODUCTION Thank you for purchasing this

More information

5.5KVA GENERATOR MODEL NO: PG6500DVES OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0616

5.5KVA GENERATOR MODEL NO: PG6500DVES OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0616 5.5KVA GENERATOR MODEL NO: PG6500DVES PART NO: 8857810 OPERATION & MAINTENANCE INSTRUCTIONS LS0616 INTRODUCTION Thank you for purchasing this CLARKE 5.5KVA Generator. Before attempting to use this product,

More information

Installation manual portable distributors

Installation manual portable distributors EN Installation manual portable distributors EN 60003206 Issue 11.2016 15/11/2016 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2 Intended

More information

AdBlue Laser V50 Installation Manual Version No: Model: AdBlue Laser V50 Date: 23/02/2018

AdBlue Laser V50 Installation Manual Version No: Model: AdBlue Laser V50 Date: 23/02/2018 AdBlue Laser V50 Installation Manual Version No: 1.0.9 Model: AdBlue Laser V50 Date: 23/02/2018 Compac Industries Ltd. 52 Walls Road. Penrose. Auckland 1061. New Zealand. PO Box 12 417. Penrose. Auckland

More information

3KVA DUAL VOLTAGE GENERATOR MODEL NO: PG3800DV

3KVA DUAL VOLTAGE GENERATOR MODEL NO: PG3800DV 3KVA DUAL VOLTAGE GENERATOR MODEL NO: PG3800DV PART NO: 8857815 OPERATION & MAINTENANCE INSTRUCTIONS LS1016 INTRODUCTION Thank you for purchasing this CLARKE 3KVA Dual Voltage Generator. Before attempting

More information

Installation Instructions for Remote Mount HMI 211 Display Panel Kit A045J206

Installation Instructions for Remote Mount HMI 211 Display Panel Kit A045J206 Instruction Sheet 7-2013 Installation Instructions for Remote Mount HMI 211 Display Panel Kit A045J206 1 Introduction The information contained within is based on information available at the time of going

More information

Getting started with

Getting started with PART NO. CMA113 MADE IN CHINA 1. Measuring CAT II 2. Max. voltage 250V ~ 3. Max. current 71 Amp Getting started with Electricity consumption & Solar PV generation monitoring single phase, for homes fitted

More information

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810 5 IN 1 JUMP START MODEL NO: JS5IN1 PART NO: 6240005 OPERATION & MAINTENANCE INSTRUCTIONS LS0810 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product, please

More information

3 TONNE TROLLEY JACK

3 TONNE TROLLEY JACK 3 TONNE TROLLEY JACK 16407 These instructions accompanying the product are the original instructions. This document is part of the product, keep it for the life of the product passing it on to any subsequent

More information

MC-CRX. Bill Acceptor Card Reader Combo. Operation & Service Manual

MC-CRX. Bill Acceptor Card Reader Combo. Operation & Service Manual MC-CRX Bill Acceptor Card Reader Combo Operation & Service Manual TABLE OF CONTENTS SECTION 1: GENERAL INFORMATION Introduction...4 Features...4 For Records...4 After Unpacking...4 Naming Convention...5

More information

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS 400W SUBMERSIBLE PUMP WITH FOLDING BASE AND FLOAT SWITCH MODEL NO: PSV6A PART NO: 7230695 OPERATION & MAINTENANCE INSTRUCTIONS LS0315 INTRODUCTION Thank you for purchasing this CLARKE 400W Submersible

More information

Installation manual wall-mounted distributor

Installation manual wall-mounted distributor EN Installation manual wall-mounted distributor EN 60003233 Issue 11.2016 2016-14-11 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2

More information

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

Fitting Instructions: Street Triple from VIN and Street Triple R from VIN A

Fitting Instructions: Street Triple from VIN and Street Triple R from VIN A English Fitting Instructions: Street Triple from VIN 560477 and Street Triple R from VIN 560477 A9808113 Thank you for choosing this Triumph genuine accessory kit. This accessory kit is the product of

More information

CONTACTS RELAY TESTER 66249

CONTACTS RELAY TESTER 66249 RELAY TESTER 66249 These instructions accompanying the product are the original instructions. This document is part of the product, keep it for the life of the product passing it on to any subsequent holder

More information

Overview of operation modes

Overview of operation modes Overview of operation modes There are three main operation modes available. Any of the modes can be selected at any time. The three main modes are: manual, automatic and mappable modes 1 to 4. The MapDCCD

More information

CONTACTS EGR VALVE TESTER 66248

CONTACTS EGR VALVE TESTER 66248 EGR VALVE TESTER 66248 These instructions accompanying the product are the original instructions. This document is part of the product, keep it for the life of the product passing it on to any subsequent

More information

SIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions

SIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions SIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

More information

SUBMERSIBLE DIRTY WATER PUMP

SUBMERSIBLE DIRTY WATER PUMP FOR USE WITH A 110V SUPPLY ONLY SUBMERSIBLE DIRTY WATER PUMP MODEL NO: DWP210A PART NO: 7230102 OPERATION & MAINTENANCE INSTRUCTIONS LS0115 INTRODUCTION Thank you for purchasing this CLARKE Submersible

More information

Authorised By: Health and Safety Committee TITLE : ELECTRICAL SAFETY GUIDELINES IN-STORE DISPLAYS

Authorised By: Health and Safety Committee TITLE : ELECTRICAL SAFETY GUIDELINES IN-STORE DISPLAYS Original Issue: May 2012 Document No.: SMS.10.2 Revision No.: v4 (May) 2014 Page: 1 of 11 Revision Date: June 2015 Authorised By: Health and Safety Committee TITLE : ELECTRICAL SAFETY GUIDELINES IN-STORE

More information

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS 750W SUBMERSIBLE PUMP WITH BUILT-IN FLOAT SWITCH MODEL NO: PSV5A PART NO: 7236046 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0917 iss 3 INTRODUCTION Thank you for purchasing this CLARKE

More information

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009 HOT WASHER MODEL NO: KING 125 PART NO: 7320170 OPERATION & MAINTENANCE INSTRUCTIONS LS1009 INTRODUCTION Thank you for purchasing this Hot Washer. This machine is a portable, high pressure power washer,

More information

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS AUTOMATIC BATTERY CHARGER / MAINTAINER MODEL NO: CBO9-12 PART NO: 6267025 OPERATION & MAINTENANCE INSTRUCTIONS LS0315 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use

More information

PSS 5000 Standard & Compact (For systems with CPB50x)

PSS 5000 Standard & Compact (For systems with CPB50x) Installation Guide Doms Forecourt Controller System PSS 5000 Standard & Compact () Date December 30, 2016 Document number PSS5000/INGU/805594/03 Doms ApS Formervangen 28 Tel. +45 4329 9490 info@doms.dk

More information

BATTERY STARTER/CHARGER MODEL NO: BC125, BC190

BATTERY STARTER/CHARGER MODEL NO: BC125, BC190 BATTERY STARTER/CHARGER MODEL NO: BC125, BC190 PART NO: 6210125, 6210200 OPERATION & MAINTENANCE INSTRUCTIONS LS0616 INTRODUCTION Thank you for purchasing this CLARKE Battery starter / charger Please read

More information

Safe Work Instructions Tools and Equipment

Safe Work Instructions Tools and Equipment Safe Work Instructions Version 1.00! 23 March 2015 Table of Contents PURPOSE AND SCOPE...4 HAND TOOLS...6 ELECTRIC POWER TOOLS...7 PETROL POWERED TOOLS...9 PORTABLE ELECTRICITY GENERATOR...12 PNEUMATIC

More information

Installation Manual. AutoSteer. Gleaner Combine. AutoGuide 2 Steer Ready. Supported Models A66 A76 R66 R76 S67 S77 PN: A

Installation Manual. AutoSteer. Gleaner Combine. AutoGuide 2 Steer Ready. Supported Models A66 A76 R66 R76 S67 S77 PN: A Installation Manual AutoSteer Gleaner Combine AutoGuide 2 Steer Ready Supported Models A66 A76 R66 R76 S67 S77 PN: 602-0312-01-A LEGAL DISCLAIMER Note: Read and follow ALL Instructions in this manual carefully

More information

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System POWER TROLLEY 8 Model: SINE 1548 Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System Version 07 CONTENTS Page 1. INTRODUCTION... 1 2. USING THE POWER TROLLEY.... 2 3. BATTERY BACKUP

More information

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos: PHASE CONVERTERS MODEL NO: PC40 and PC60 MODEL PART No: NO: 6012805 PC20 and PC40 6012810 PC60 PART Nos: 6012800 6012805 6012810 OPERATING & MAINTENANCE INSTRUCTIONS 0107 Specifications PC20 PC40 PC60

More information

2014 GM Truck Level 1 Performance Pack

2014 GM Truck Level 1 Performance Pack 2014 GM Truck Level 1 Performance Pack Installation Instructions P/N: 2414-PRFPC1-AA Application: 2014+ Chevy Silverado and GMC Sierra 5.3L and 6.2L Important Note: Before installing your Blackwing cold

More information

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105 250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105 PART NO: 7230693 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0917 -- iss 3 INTRODUCTION Thank you for purchasing this CLARKE 250W Puddle

More information

BATTERY CHARGER-STARTER

BATTERY CHARGER-STARTER BATTERY CHARGER-STARTER MODEL NO: WBC240 & WBC400 PART NO: 6261505 & 6261515 OPERATION & MAINTENANCE INSTRUCTIONS GC0116 INTRODUCTION Thank you for purchasing this CLARKE Battery Charger/Starter. Please

More information

C4000 Master Manual. Version 1.0.0

C4000 Master Manual. Version 1.0.0 C4000 Master Manual Version 1.0.0 Conditions of Use Read this manual completely before working on or making adjustments to the Compac equipment. Compac Industries Limited accepts no liability for personal

More information

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS AUTOMATIC BATTERY CHARGER / MAINTAINER MODEL NO: CBO9-6/12 PART NO: 6267020 OPERATION & MAINTENANCE INSTRUCTIONS LS0615 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use

More information

Cordless Rechargeable Saw Instructions for Use

Cordless Rechargeable Saw Instructions for Use Technical data Voltage: DC 10.8V Weight: 1.25Kg Stroke rate: 0-2100/min Stroke: 15mm Cutting capacity: max diameter in wood 80mm / in soft metal 7mm Charging time: Between 5.0-5.5 Hours Battery: 1.3Ah

More information

2 TONNE TROLLEY JACK

2 TONNE TROLLEY JACK 2 TONNE TROLLEY JACK 61829 IMPORTANT: Please read these instructions carefully to ensure the safe and effective use of this product and save these instructions for future reference. This manual has been

More information

B-RAD Select USER MANUAL TABLE OF CONTENTS

B-RAD Select USER MANUAL TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE... 3 1.0 General Information... 5 1.1 System Components... 5 1.2 Specifications... 5 1.2.1 Torque Ranges...

More information

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: & HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: 5460600 & 5460595 OPERATING & MAINTENANCE INSTRUCTIONS GC0610 INTRODUCTION Thank you for purchasing this CLARKE Halogen Floodlight. Before attempting

More information

Name: ACORN Inc. Address: 6450 Kingspointe Parkway, Unit 1, Orlando, Florida, IMPORTANT!

Name: ACORN Inc. Address: 6450 Kingspointe Parkway, Unit 1, Orlando, Florida, IMPORTANT! MANUFACTURER INFORMATION: Name: ACORN Inc. Address: 6450 Kingspointe Parkway, Unit 1, Orlando, Florida, 32819 Helpline: 407 650-0216 IMPORTANT! READ THESE PROCEDURES THOROUGHLY PRIOR TO stair lift INSTALLATION

More information

CFT24 &CFT230 PART NOS:

CFT24 &CFT230 PART NOS: FUEL TRANSFER PUMP Model Nos. CFT12, CFT24 &CFT230 PART NOS: 7160010, 7160020 & 7160030 INSTALLATION & OPERATING INSTRUCTIONS ORIGINAL INSTRUCTIONS GC05/18 REV 5 INTRODUCTION Thank you for purchasing this

More information

Electric Vehicle Charging Station

Electric Vehicle Charging Station EVoReel Electric Vehicle Charging Station INSTALLATION GUIDE AND USER MANUAL Model: Dual Output Pedestal Mount 30A EVoReel EVSE Model Numbers: With Basic EVSE: EV072-400-002A; With Intelligent ievse: EV072-410-002A;

More information

Accessory Kit Estimated Fitting Time: 120 Minutes

Accessory Kit Estimated Fitting Time: 120 Minutes Landcruiser LC00 Tow-Pro Wiring Kit - Landcruiser LC00 Kit Part No: TPWKIT - 005 Accessory Kit Estimated Fitting Time: 0 Minutes FI88 Page 0 of Issue: Date: 7/09/07 07 General Notes Safety Notes Parts

More information

TESTER SET SOCKET & VOLTAGE

TESTER SET SOCKET & VOLTAGE SOCKET & VOLTAGE TESTER SET 82384 These instructions accompanying the product are the original instructions. This document is part of the product, keep it for the life of the product passing it on to any

More information

ILED Aquarius Illuminated Windsock. User Manual

ILED Aquarius Illuminated Windsock. User Manual Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 3.1 The light fitting has a type plate:... 4 3.2 The junction box has a type plate:... 5 4. Product Description...

More information

GENERATOR MODEL NO: FG2500 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0114

GENERATOR MODEL NO: FG2500 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0114 GENERATOR MODEL NO: FG2500 PART NO: 8857727 OPERATION & MAINTENANCE INSTRUCTIONS LS0114 INTRODUCTION Thank you for purchasing this CLARKE Generator. Before attempting to use this product, please read this

More information

SPEEDKEY KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev Page 1 of 9. GEM e2, e4, e6, el XD

SPEEDKEY KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev Page 1 of 9. GEM e2, e4, e6, el XD SPEEDKEY KIT P/N 2883054 APPLICATION GEM e2, e4, e6, el XD BEFORE YOU BEGIN Read these instructions and check to be sure all parts and tools are accounted for. Please retain these installation instructions

More information

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC Automatic Battery Charger Switching mode with Micro-controlled Input:220-260Vac / Output: 12Volt DC User s Manual and Important Safety Information Model: OC-SW121080 / OC-SW121160 / OC-SW121210 FEATURES

More information

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS AUTOMATIC BATTERY CHARGER / MAINTAINER MODEL NO: CBO9-12 PART NO: 6267025 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0118 - ISS 3 INTRODUCTION Thank you for purchasing this CLARKE product.

More information

Installation Instructions. PowerFlex 700 Drive - Frame 8 Components Replacement

Installation Instructions. PowerFlex 700 Drive - Frame 8 Components Replacement Installation Instructions PowerFlex 700 Drive - Frame 8 Components Replacement Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical

More information

Operations and Service Manual. X30208 Load Bank

Operations and Service Manual. X30208 Load Bank Operations and Service Manual Read all instructions before using the load bank Contents 1. Components... 3 Total Assembly... 3 2) Specifications... 4 a)... 4 3) Receiving... 5 4) Safety... 5 a) Ground

More information

Navigator ADS551 Low level dissolved oxygen Replacement / Upgrade procedures wet section spares

Navigator ADS551 Low level dissolved oxygen Replacement / Upgrade procedures wet section spares Instruction replacement procedure INS/ANAINST/025 EN Rev. A Navigator ADS551 Low level dissolved oxygen Replacement / Upgrade procedures wet section spares Kit references: flowcell, tundish, flowmeter,

More information

OPERATION AND MAINTENANCE

OPERATION AND MAINTENANCE Table of Contents GENERAL INFORMATION INTRODUCTION... 1 Operating Specifications... 1 FEATURES... 1 SAFETY PRECAUTIONS... 2 SET-UP... 2 OPERATION AND MAINTENANCE TESTING AN IGNITION MODULE OR IGNITION

More information

720W PORTABLE GENERATOR

720W PORTABLE GENERATOR 720W PORTABLE GENERATOR MODEL NO: G720 PART NO: 8857800 OPERATION & MAINTENANCE INSTRUCTIONS LS0214 INTRODUCTION Thank you for purchasing this CLARKE 720W Portable Generator Before attempting to use this

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 2581 INSTALLATION INSTRUCTIONS 08-15 IMPORTANT PLEASE DON T HURT YOURSELF, THE KIT, OR YOUR VEHICLE. TAKE A MINUTE TO READ THIS IMPORTANT INFORMATION. SAFE INSTALLATION Please take all safety precautions

More information

U L T I M A T E R A D A R / L A S E R D E F E N S E S Y S T E M

U L T I M A T E R A D A R / L A S E R D E F E N S E S Y S T E M S m a r t e r Q u i e t e r M o r e A c c u r a t e U L T I M A T E R A D A R / L A S E R D E F E N S E S Y S T E M Installation Manual PASSPORT 9500ci Comes Complete Front Radar Receiver Miniature weatherproof

More information

HOMEBASE STATION M A N A G E M E N T F O R C O M M E R C I A L F L E E T S

HOMEBASE STATION M A N A G E M E N T F O R C O M M E R C I A L F L E E T S HOMEBASE STATION M A N A G E M E N T F O R C O M M E R C I A L F L E E T S CONTENTS Overview............ 1 Benefits............ 3 Solution Description........ 4 The Components......... 5 2 HOMEBASE STATION

More information

Fitting Instructions

Fitting Instructions Tow-Pro Wiring Kit Fitting Instructions Holder Colorado / Colorado 7 Accessory Kit Estimated Fitting Time: 0 Minutes FI7 Page 0 of General Notes Read through the fitting instructions before installation

More information

WARNING: Read these instructions before using the machine GENERATOR MODEL NO: IG3500F PART NO: OPERATION & MAINTENANCE INSTRUCTIONS

WARNING: Read these instructions before using the machine GENERATOR MODEL NO: IG3500F PART NO: OPERATION & MAINTENANCE INSTRUCTIONS WARNING: Read these instructions before using the machine GENERATOR MODEL NO: IG3500F PART NO: 8877100 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0217 INTRODUCTION Thank you for purchasing

More information

My Reserve 500 Install Guide

My Reserve 500 Install Guide My Reserve 500 Install Guide System Overview Diagram Warnings Disclaimer of Liability and Warranty: This guide does not replace the Owner s Guide and Installation Instructions supplied with the components.

More information

BMW i. Freude am Fahren. BMW i Wallbox Plus. Instructions for use

BMW i. Freude am Fahren. BMW i Wallbox Plus. Instructions for use BMW i Freude am Fahren BMW i Wallbox Plus Instructions for use 5 EN BMW i Wallbox Plus Instructions for use BMW i Wallbox Plus Instructions for use INFORMATION Safety information Intended use About this

More information

Operating Instructions. bluesmart Active

Operating Instructions. bluesmart Active Table of contents 1. Overview 3 2. Safety 3 2.1 Symbols in these instructions 3 2.2 Intended use 4 2.3 Responsibility of the operator 4 3. Setup and function 4 3.1 Brief description 4 3.2 Overview 5 3.3

More information

MMA 160S ARC/MMA WELDER OPERATION INSTRUCTIONS

MMA 160S ARC/MMA WELDER OPERATION INSTRUCTIONS www.r-techwelding.co.uk MMA 160S ARC/MMA WELDER OPERATION INSTRUCTIONS 2 Thank you for selecting the R-Tech MMA160S Inverter Arc Welder. The MMA160S has many benefits over traditional Arc welders, including

More information

CARM INTERNATIONAL TOWING MODULES

CARM INTERNATIONAL TOWING MODULES CARM INTERNATIONAL TOWING MODULES (TA100/200 Instructions Revision = 1) Each Towing Module (if ordered with Loom Pack) is shipped with: A/ These instructions B/ 1 x Towing Control Module C/ 1 x high current

More information

GENERATOR MODEL NO: FG3005 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0413

GENERATOR MODEL NO: FG3005 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0413 GENERATOR MODEL NO: FG3005 PART NO: 8857707 OPERATION & MAINTENANCE INSTRUCTIONS LS0413 INTRODUCTION Thank you for purchasing this CLARKE Generator. Before attempting to use this product, please read this

More information

Fitting Instructions

Fitting Instructions Reverse Park Assist Suitable for: Nissan Navara Kit Part No: 5466XX NP00 Tow-Pro Wiring Kit Fitting Instructions Accessory Kit Estimated Fitting Time: 0 Minutes FI98 Page 0 of 5 General Notes Read through

More information

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS1010

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS1010 ELECTRIC HOIST MODEL NO: CH2500B, CH4000B PART NO: 7630386, 7630391 OPERATION & MAINTENANCE INSTRUCTIONS LS1010 INTRODUCTION Thank you for purchasing this CLARKE Electric Hoist. Before attempting to use

More information

OPERATION INSTRUCTIONS

OPERATION INSTRUCTIONS www.r-techwelding.co.uk Email: sales@r-techwelding.co.uk Tel: 01452 733933 Fax: 01452 733939 ProArc 175 INVERTER ARC WELDER OPERATION INSTRUCTIONS Version 2017-10 2 3 Thank you for selecting the R-Tech

More information

TABLE OF CONTENTS INTRODUCTION.. 3. A/C Ducting Installation. Power Kit Installation (Batteries)...5 OPERATION MANUAL 7-8 TOOLS LIST..

TABLE OF CONTENTS INTRODUCTION.. 3. A/C Ducting Installation. Power Kit Installation (Batteries)...5 OPERATION MANUAL 7-8 TOOLS LIST.. 585457 1 TABLE OF CONTENTS SECTION PAGE INTRODUCTION.. 3 INSTALLATION PROCEDURES Air Conditioner Location...4 Air Conditioner Mounting 4 A/C Ducting Installation...5 Power Kit Installation (Batteries)...5

More information

AFS-GC90 MAGNESIUM OXIDE SPREADER. Operators Manual

AFS-GC90 MAGNESIUM OXIDE SPREADER. Operators Manual AFS-GC90 MAGNESIUM OXIDE SPREADER Operators Manual Reese Engineering Ltd Palmerston North, New Zealand Telephone: +64 6 357 9323 Facsimile: +64 6 354 3155 www.reeseagri.com 2 Contents OWNER INFORMATION...

More information

Car Battery Charger Instructions for Use

Car Battery Charger Instructions for Use BATTERY CHARGER 12Volt 4Amp FOR INDOOR USE ONLY Power Details: Input: 230-240Vac; 50Hz; 52W Output: 12V DC; 2.8A Maximum Charge Rate: 4A RMS Read these instructions before operating this car battery charger

More information

English. Fitting Instructions: Trophy and Trophy SE A of 12. Parts Supplied:

English. Fitting Instructions: Trophy and Trophy SE A of 12. Parts Supplied: English Fitting Instructions: Trophy and Trophy SE A9808015 Thank you for choosing this Triumph genuine accessory kit. This accessory kit is the product of Triumph's use of proven engineering, exhaustive

More information