BUG PREP KIT 2.0 HAND-PREP SYSTEM. User Manual REV A reva0616

Size: px
Start display at page:

Download "BUG PREP KIT 2.0 HAND-PREP SYSTEM. User Manual REV A reva0616"

Transcription

1 BUG PREP KIT 2.0 HAND-PREP SYSTEM User Manual REV A reva0616 Hydra-Flex, Hydra-Flex, Inc Inc Page 1

2 TABLE OF CONTENTS Overview 3 Standard Bug Prep Kit Bug Prep Retro Controller (Retro Only) 3 Bug Prep Kit 2.0 Retro Installation Steps 4 Bug Prep 2.0 Installation Steps 6 Standard Operating Procedure 7 How To Reduce Temp If Temp Overload Box is Tripped 7 Trouble Shooting 7 Preventative Maintenance 7 Bug Prep Kit 2.0 Warranty 8 FOR ADDITIONAL SUPPORT CALL OR VISIT US ON THE WEB: Hydra-Flex, Inc Page 2

3 OVERVIEW The Aqua-Lab Bug Prep Kit 2.0 integrates injector-based chemical dispensing with a pressure switch actuated foaming prep gun and a high temperature shutdown system to protect your pumps. The injector plugs into a Hydra-Cannon position and turns on the pump to create boosted chemical solution when a hand actuated gun is squeezed. If a failure occurs somewhere in the system causing the pump to run and bypass water the temperature switch detects the temperature increase and shuts down the pump. If the pump is shut down due to a temperature trip a red light will become illuminated. STANDARD BUG PREP KIT 2.0 Outlet Solution Line Pressure Switch Box Din I Plug M12 Connector Injector Assembly BUG PREP RETRO CONTROLLER (RETRO ONLY) 3 Pin Electrical Quick Connect (Retrofit Prep Only) 120V Wall Outlet Plug In Temperature Overload Reset Button 2 Pin Electrical Quick Connect 3 Pin Electrical Quick Connect Hydra-Flex, Inc Page 3

4 BUG PREP KIT 2.0 RETRO INSTALLATION STEPS 1. Mount bug prep pressure switch box within 3 of Aqua-Lab panel M12 junction block. 2. Mount temperature overload box next to panel within 32 of the bug prep pressure switch box and within 14 of the pump that plumbs into the corresponding Aqua-Lab panel the bug prep. 3. Shutoff water to pump inlet, turn off power to pump (not shown). 4. Close ball valve at the Hydra-Cannon inlet. 5. Disconnect quick connect on feed line to panel (not shown). 6. Aim hose at drain. Open ball valve and run till water stops coming out of hose. 7. Plumb temperature switch into bypass line (see photos below). 8. Connect injector to manifold. Route 1/2 poly flow to top port on pressure switch box. Step 6 Step 7 Step 7 Cut Bypass line close to the end of hose bar, loosen hose clamp Plumb in temp switch to regulator, connect hose to hose barb and re-tighten hose clamp 9. Plumb outlet solution line (3/8 poly flow from side port of pressure switch box) and airline to bay (not included). 10. Connect solution and airline to dual lumen hose. 11. Connect dual lumen hose to wye connector on foaming gun (Red Line is used for air, Blue Line is used for chemical solution). 12. Attach M12 connector on injector manifold to corresponding Aqua-Lab junction block port. 13. Connect Din I to corresponding Aqua-Lab electric actuated air valve. 14. Connect 3 pin electrical quick connect on injector manifold to 3 pin electrical quick connect on temperature shutdown box. Connect 2 pin electrical quick connect on temperature switch to 2 pin electrical quick connect on temperature shutdown box. a. Turn on water supply to pump (not shown). b. When water is coming out of feed line for 30 seconds close ball valve, re-prime pump (not shown). c. Reconnect feed line to panel (not shown). d. Press red light on temperature overload box. 15. Open ball valve on feed line, pump and valve will activate until 100 psi is stored in line. Once pressure is made between the gun and valve, the pump will turn off after approximately 20 seconds (not shown). 16. Verify that the system is leak free (not shown). 17. Verify that the pump turns on when the gun trigger is squeezed (not shown). 18. Verify the pump turns off when the gun in closed (not squeezed). Pump should turn off after approximately 20 seconds of releasing the gun (not shown). Hydra-Flex, Inc Page 4

5 Step 2 Step 15d Step 13 Step 12 Step 14 Step 8 Step 4 Step 1 Step 9 Step 15 Step 10 Step 11 Hydra-Flex, Inc Page 5

6 BUG PREP KIT 2.0 INSTALLATION STEPS 1. Mount bug prep pressure switch box within 3 of Aqua-Lab panel M12 junction block. 2. Close ball valve at the Hydra-Cannon inlet, turn off power to pump. 3. Connect injector to manifold, route ½ poly flow tubing to top port on pressure switch box. 4. Plumb outlet solution line (3/8 poly flow from side port of pressure switch box) and airline to bay (not included). 5. Connect solution line and airline to dual lumen hose. 6. Connect dual lumen hose to wye connector on foaming gun (red line is used for air, blue line is used for chemical solution). 7. Attach M12 connector on injector manifold to corresponding Aqua-Lab junction block port. 8. Connect Din I to corresponding Aqua- Lab electric actuated air valve. Step 2 Step 1 9. Once all plumbing and electrical connections are made, turn on power to the pump and slowly open the ball valve at the inlet of the Hydra-Cannon manifold. The pump will remain on until 100 PSI is stored in the solution outlet line. (This should take approximately 20 seconds.) 10. Verify that the system is leak free. Step 6 Step Verify that the pump turns on when the gun trigger is squeezed. Step 8 Step 7 Step 3 Step Verify the pump turns off when the gun in closed (not squeezed). Pump should turn off after approximately 20 seconds of releasing the gun. Hydra-Flex, Inc Page 6

7 hydraflexinc.com STANDARD OPERATING PROCEDURE 1. Squeeze hand applicator trigger. a. Pump will turn on and valve will open simultaneously. 2. Apply solution to vehicle. 3. Release hand applicator trigger. a. Pump will build pressure in the bug prep solution line to 100 PSI and pump will shut down approx. 20 seconds later. HFI STRONGLY RECOMMENDS SHUTTING DOWN YOUR SYSTEM AT NIGHT TO PREVENT ANY UNINTENDED OPERATION HOW TO REDUCE TEMPERATURE IF TEMPERATURE OVERLOAD BOX IS TRIPPED 1. Close ball valve at inlet to Hydra-Cannon manifold. 2. Press red button on electric actuated air valve to purge pressure. a. Press and hold red button to purge pressure. Disconnect ball valve from Hydra-Cannon Inlet once pressure gauge reads 0 PSI. 3. Point valve towards drain, and slowly open to flush water through pump. Flushing water through pump will cool down the thermal switch. Once the thermal switch is cooled, press the illuminated red light on temperature overload box and reconnect ball valve to the panel. 4. Open ball valve. TROUBLE SHOOTING PROBLEM POTENTIAL CAUSES SOLUTIONS Injector Does Not Draw Chemical Pump Does Not Turn On Pump Will Not Turn Off 1. Back pressure is too high. 2. Metering tip clogged. 3. Foot valve is clogged. 1. Temperature overload is not plugged in. 2. Light on temperature overload box is illuminated. 3. Temperature overload is tripped. 1. Leak in line 2. Pressure switch failed PUMP 1 AQUA-LAB MD5 Chemical Dispensing System 1. Reduce foaming air pressure. 2. Increase nozzle size. 3. Increase solution outlet line size. 4. Clean/replace foam generators. 5. Clean metering tip. 6. Clean foot valve. 1. Plug temperature overload box in. 2. Press temperature overload reset button. 3. Reduce pump temperature by purging pump system with cold water, hit reset button once pump has been purged with cold water. 1. Fix leaks 2. Replace injector manifold 3. Replace check valve on airline Air Valve Chatters 1. Back pressure is too high 1. Decrease back pressure to below 60 PSI PREVENTATIVE MAINTENANCE TIME FRAME Daily Weekly Monthly ACTION Check for standard operating function: When the gun handle is squeezed, the pump turns on. When the gun handle is released, the pump turns off. Check for leaks that may cause the pressure switch to trigger. Inspect check valves on airlines to make sure valves are working. Replace when needed. Hydra-Flex, Inc Page 7

8 BUG PREP KIT 2.0 WARRANTY FACTORY LIMITED Hydra-Flex, Inc warrants its equipment to be free from defect in material or workmanship under proper normal use for a period of one (1) year beginning the date of purchase. Hydra-Flex, Inc s liability shall be limited to repair or replacement of parts found to be defective within the warranty period and following Hydra-Flex, Inc s inspection. Hydra-Flex, Inc shall have the option requiring the return of defective material to establish the purchaser s claim. In the event of repair or replacement this limited warranty is non-cumulative. Neither labor nor transportation charges are included in this warranty. This warranty is based upon the proper care and maintenance of the warranted equipment. Warranty does not apply if the merchandise is altered or modified in any way. Warranty does not apply to any equipment which has been subject to misuse, inappropriate use of tools, including exposure to harsh chemicals, neglect, lack of maintenance, freezing, fluid hammer, accident, third party damage, fluid impurities such as sand or minerals, acts of God or acts of war. Nor does it apply to any equipment which has been repaired or altered by anyone not so authorized by Hydra-Flex, Inc. All equipment must be properly installed in accordance with specified plumbing, electrical, and mechanical requirements. The warranty does not apply to normal wear and tear or routine maintenance components as described in the equipment manual. Except as expressly stated herein, Hydra-Flex, Inc shall not be liable for damages of any kind in connection with the purchase, maintenance, or use of this equipment including loss of profits and all claims for consequential damages. This limited warranty is in lieu of all other warranties expressed or implied. Hydra-Flex, Inc neither assumes nor authorizes any person to assume for it any other obligation or liability in connection herewith. This warranty is neither assignable nor transferable. Transportation damage claims are to be submitted to the carrier of the damaged material sales@hydraflexinc.com Hydra-Flex, Inc reva0616 Page 8

AQUA-LAB Chemical Dispensing System. Operating Manual REV L

AQUA-LAB Chemical Dispensing System. Operating Manual REV L AQUA-LAB Chemical Dispensing System Operating Manual REV L Specifications 1. Operating water pressure: 200 psi (Factory set) 2. Pneumatics operating pressure: 100 psi (Factory set) 3. Maximum water source

More information

Air Compressor. Owner s Manual. Sonny's Enterprises, Inc Hiatus Road Tamarac, Florida v1

Air Compressor. Owner s Manual. Sonny's Enterprises, Inc Hiatus Road Tamarac, Florida v1 Owner s Manual Sonny's Enterprises, Inc. 5605 Hiatus Road Tamarac, Florida 33321 16v1 *Table of Contents* WARNING *SAFETY REQUIREMENTS* WARNING... 3 *INTRODUCTION*... 5 Product Specifications... 6 Optional

More information

Cyclone Trash Separator

Cyclone Trash Separator Owner's Manual Sonny's Enterprises, Inc. 5605 Hiatus Road Tamarac, Florida 33321 16v1 *Table of Contents* WARNING *SAFETY REQUIREMENTS* WARNING... 3 *INTRODUCTION*... 5 Product Specifications... 6 *INSTALLATION*...

More information

BLAST-TEC PRO. Rotating Turbo Nozzles. Optimization & Troubleshooting Guide REV C revc0118

BLAST-TEC PRO. Rotating Turbo Nozzles. Optimization & Troubleshooting Guide REV C revc0118 BLAST-TEC PRO Rotating Turbo Nozzles Optimization & Troubleshooting Guide REV C 4000002 revc08 Hydra-Flex, Hydra-Flex, Inc. 208 Inc. 208 TABLE OF CONTENTS Product Overview Product Line Description Specifications

More information

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

CLEAN ROOM DEVICES, LLC WHERE TUBING AND FITTINGS COME TOGETHER CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER" CRD600 Automatic Fitting Inserter OPERATIONS MANUAL VERSION 2.1 LAST EDITED 7.25.14 DOCUMENT NUMBER 001 cleanroomdevices.com 1 Table of

More information

CRD610 Automatic Fitting Inserter

CRD610 Automatic Fitting Inserter CRD610 Automatic Fitting Inserter OPERATIONS MANUAL VERSION 1.2 LAST EDITED 12.12.2018 cleanroomdevices.com 1 Table of Contents Title Page. 1 Table of Contents...2 1.0 General Product & Safety Information....3

More information

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

CLEAN ROOM DEVICES, LLC WHERE TUBING AND FITTINGS COME TOGETHER CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER" CRD600AF Automatic Fitting Inserter With Auto Feed OPERATIONS MANUAL (Shown with optional alcohol dispenser) 1 VERSION 1.1 LAST EDITED

More information

Top Brush Auto Retract (Zelio PLC)

Top Brush Auto Retract (Zelio PLC) () Owner s Manual Sonny's Enterprises, Inc. 5605 Hiatus Road Tamarac, Florida 33321 16v1 *Table of Contents* Equipment Program - Manuals WARNING *SAFETY REQUIREMENTS* WARNING... 3 *INTRODUCTION*... 5 Product

More information

AQUA-LAB SD CHEMICAL DISPENSING SYSTEM. User Manual REV G revg0518

AQUA-LAB SD CHEMICAL DISPENSING SYSTEM. User Manual REV G revg0518 AQUA-LAB SD CHEMICAL DISPENSING SYSTEM User Manual REV G 4000061 revg0518 Hydra-Flex, Hydra-Flex, Inc. 2018 Inc. 2017 TABLE OF CONTENTS Specifications 1 Aqua-Lab SD System Diagrams 2 Layout Drawing 4 Estimated

More information

PPM EO-100 TM. Operation Manual

PPM EO-100 TM. Operation Manual PPM EO-100 TM Open Loop Electric Prewet Power Module Operation Manual Rev A Page 1 2/23/2010 Copyright 2008 by Cirus Controls, LLC. All Rights Reserved. No part of this material may be reproduced in any

More information

CRD600 Automatic Fitting Inserter

CRD600 Automatic Fitting Inserter CRD600 Automatic Fitting Inserter OPERATIONS MANUAL VERSION 2.3 LAST EDITED 12.07.2018 cleanroomdevices.com 1 Table of Contents Title Page.. 1 Table of Contents. 2 1.0 General Product & Safety Information...3

More information

INSTALLATION INSTRUCTIONS, PARTS LIST AND CONFIGURATION GUIDE FOR THE CARBONATOR. Large Model No

INSTALLATION INSTRUCTIONS, PARTS LIST AND CONFIGURATION GUIDE FOR THE CARBONATOR. Large Model No Please refer to the Schroeder America website (www.schroederamerica.com) for information relating to Schroeder America installation and Service Manuals, Instruction Sheets, Technical Bulletins, Service

More information

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately.

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately. LSF Start-Up Instructions 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately. 2) PRE-START-UP: Be sure there is water in the pump. Bleed air at all high points

More information

AQUA-LAB AX, BX, TX. CHEMICAL DISPENSING SYSTEM User Manual REV A reva0717

AQUA-LAB AX, BX, TX. CHEMICAL DISPENSING SYSTEM User Manual REV A reva0717 AQUA-LAB AX, BX, TX CHEMICAL DISPENSING SYSTEM User Manual REV A 4000133 reva0717 Hydra-Flex, Hydra-Flex, Inc. 2017 Inc. 2017 TABLE OF CONTENTS Overview 1 Features 1 Specifications 1 Installation Instructions

More information

QUALITY MISTING PUMPS

QUALITY MISTING PUMPS DIRECT DRIVE TOTALLY ENCLOSED FAN COOLED 60200KH, 60201KH MISTING PUMP MANUAL INCLUDING: SPECIFICATION DATA, GENERAL SAFETY PRECAUTIONS, OPERATION, INSTALLATION, PARTS, MAINTENANCE & WARRANTY QUALITY MISTING

More information

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type INSTRUCTIONS-PARTS LIST 306 460 INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Rev. E Supercedes D Detachable-type LUBRICATOR GUN 10,000 psi (700 bar)

More information

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings -

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings - Instructions Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. 311082D Pressure Roller with 24-inch Fixed Extension - For application of architectural

More information

Maintenance Manual. Automated Fuel Maintenance System FTI-5A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL

Maintenance Manual. Automated Fuel Maintenance System FTI-5A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL Maintenance Manual Automated Fuel Maintenance System FTI-5A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL 05/01/2016 Rev A Fuel Technologies FTI-5A Single Tank Maintenance Section FTI - Fuel Maintenance

More information

LBT-3 WITH 300 CFM RECLAIM MANUAL NUMBER: 506 TABLE OF CONTENTS

LBT-3 WITH 300 CFM RECLAIM MANUAL NUMBER: 506 TABLE OF CONTENTS LITTLE BLASTER LITTLE BLASTER LBT-3 WITH 300 CFM RECLAIM MANUAL NUMBER: 506 TABLE OF CONTENTS PAGE FIGURE 1 - SET-UP INSTRUCTIONS 1 - OPERATING INSTRUCTIONS 1 - GENERAL MAINTENANCE 2 1 STANDARD CABINET

More information

AQUA-LAB SD GEN2 CHEMICAL DISPENSING SYSTEM. User Manual REV B revb0518

AQUA-LAB SD GEN2 CHEMICAL DISPENSING SYSTEM. User Manual REV B revb0518 AQUA-LAB SD GEN2 CHEMICAL DISPENSING SYSTEM User Manual REV B 4000122 revb0518 Hydra-Flex, Hydra-Flex, Inc. 2018 Inc. 2018 Page 1 TABLE OF CONTENTS Specifications 3 Layout Drawing 4 Panel Diagram 5 Motor

More information

Pro Shot Grease Dispense Valve

Pro Shot Grease Dispense Valve Instructions Parts List Pro Shot Grease Dispense Valve 309032J For high pressure grease dispense. 8000 psi (55 MPa, 552 bar) Maximum Working Pressure Model No. 242055, Series B, 1/4 npt Fluid Inlet Model

More information

Wash Prep Systems featuring CAT PUMPS DUPM623 DUPM820 / DUPM820-TS DUPM820D / DUPM820D-TS DUPM1010. Owner s Manual #

Wash Prep Systems featuring CAT PUMPS DUPM623 DUPM820 / DUPM820-TS DUPM820D / DUPM820D-TS DUPM1010. Owner s Manual # Wash Prep Systems featuring CAT PUMPS DUPM623 DUPM820 / DUPM820-TS DUPM820D / DUPM820D-TS DUPM1010 Serial Number: Owner s Manual #0779 072415 Installation Date: Please read and understand this manual.

More information

Medi-Flow. Model M101 & M101D Medicator Instructions GETTING TECHNICAL ASSISTANCE

Medi-Flow. Model M101 & M101D Medicator Instructions GETTING TECHNICAL ASSISTANCE UNPACKING Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing materials to arrive to you undamaged. If you do find an item that is broken

More information

Maintenance Manual WITH ONE SUBMERSIBLE PUMP. Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL LLC

Maintenance Manual WITH ONE SUBMERSIBLE PUMP. Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL LLC Maintenance Manual WITH ONE SUBMERSIBLE PUMP Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL LLC Replacement Manuals Available on Website: www.fueltechnologiesinternational.com

More information

Economy Wash Package DU EWS10-31, DU EWS10-51

Economy Wash Package DU EWS10-31, DU EWS10-51 Economy Wash Package DU EWS10-31, DU EWS10-51 Owner s Manual #0812 Customer Number: Model Number: Serial Number: Installation Date: IMPORTANT Please read and understand this manual. Store in safe location

More information

Premium Series Grease Dispensing Handle One and Two Piece Body Styles

Premium Series Grease Dispensing Handle One and Two Piece Body Styles Service Bulletin SB3018 Rev. A 3/07 Premium Series Grease Dispensing Handle One and Two Piece Body Styles Models: Handle w/swivel and 36" Whip Hose 020 Handle w/swivel and 18" Whip Hose 025 Handle w/swivel

More information

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS AEROMOTIVE Part # 16303 INSTALLATION INSTRUCTIONS CAUTION: Installation of this product requires detailed knowledge of automotive systems and repair procedures. We recommend that this installation be carried

More information

PARTS AND INSTALLATION MANUAL

PARTS AND INSTALLATION MANUAL PSP-3240 POLYPROPYLENE SELF-PRIMING 2 CENTRIFUGAL PUMP PARTS AND INSTALLATION MANUAL PSP-3240 Shown with GX-160 Honda CDS-JOHN BLUE COMPANY DIVISION OF ADVANCED SYSTEMS TECHNOLOGY, INC. 165 Electronics

More information

QUALITY MISTING PUMPS

QUALITY MISTING PUMPS TOTALLY ENCLOSED DIRECT DRIVE 60030KH, 60031KH, 60050KH, 60051KH 60100KH, 60101KH, 60150KH, 60151KH MISTING PUMP MANUAL INCLUDING: SPECIFICATION DATA, GENERAL SAFETY PRECAUTIONS, OPERATION, INSTALLATION,

More information

AQUA-LAB MD CHEMICAL DISPENSING SYSTEM. User Manual REV V revv0118

AQUA-LAB MD CHEMICAL DISPENSING SYSTEM. User Manual REV V revv0118 AQUA-LAB MD CHEMICAL DISPENSING SYSTEM User Manual REV V 0000 revv08 Hydra-Flex, Hydra-Flex, Inc. 08 Inc. 08 Page TABLE OF CONTENTS Specifications Layout Drawings Booster Pump & MCU Layout Drawings Grundfos

More information

BLAST-TEC PRO - ROTATING TURBO NOZZLES

BLAST-TEC PRO - ROTATING TURBO NOZZLES BLAST-TEC PRO - ROTATING TURBO NOZZLES BLAST-TEC PRO ROTATING TURBO NOZZLE - 1000 PSI The Blast-Tec Pro was designed specifically for high-pressure, high-impact vehicle wash applications including wheel

More information

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser INSTRUCTIONS-PARTS LIST 30 455 INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Rev. C Supercedes B Hand-Operated Portable Grease Dispenser Buckshot Luber

More information

High Pressure Pump Units featuring CAT PUMPS DUPM550 & DUPM570

High Pressure Pump Units featuring CAT PUMPS DUPM550 & DUPM570 High Pressure Pump Units featuring CAT PUMPS DUPM550 & DUPM570 Serial Number: Owner s Manual #0789 122315 Installation Date: Please read and understand this manual. Store in safe location for future reference.

More information

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps INSTALLATION MANUAL Series: 1/12HP, 5000 RPM, 60 Hz ISP No: - 6/09 General Safety Information Before installation, read the following instructions carefully. Failure to follow instruction and Safety information

More information

Maintenance Manual. Automated. Fuel Maintenance System FTI-5A. FUEL TECHNOLOGIES INTERNATIONAL LLC

Maintenance Manual. Automated. Fuel Maintenance System FTI-5A. FUEL TECHNOLOGIES INTERNATIONAL LLC Maintenance Manual Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL LLC www.fueltechnologiesinternational.com 03/01/2011 - Fuel Technologies FTI-5A Maintenance Section FTI - Fuel

More information

CAT PUMPS (7.5 HP) Pump Stations DU PS1901C-PG & DU PS1901CPG2 DU PS1903C-PG & DU PS1903CPG2

CAT PUMPS (7.5 HP) Pump Stations DU PS1901C-PG & DU PS1901CPG2 DU PS1903C-PG & DU PS1903CPG2 CAT PUMPS (7.5 HP) Pump Stations DU PS1901C-PG & DU PS1901CPG2 DU PS1903C-PG & DU PS1903CPG2 Serial Number: Owner s Manual #0806 120710 Installation Date: Please read and understand this manual. Store

More information

Single Pump Station with Delay, 10HP/1PH DU PS2001C-PG

Single Pump Station with Delay, 10HP/1PH DU PS2001C-PG Single Pump Station with Delay, 10HP/1PH DU PS2001C-PG Owner s Manual #0810 Customer Number: Model Number: Serial Number: Installation Date: Please read and u n d e r s t a n d t h i s manual. Store in

More information

StormPro BA Series Sump Pump

StormPro BA Series Sump Pump Page 1 of 8 Marks & Meanings DANGER: Keep the pump equipment out of the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects. WARNING:

More information

Agxcel GX12i Chemical Injection System

Agxcel GX12i Chemical Injection System Agxcel GX12i Chemical Injection System Table of Contents System Contents... 3 Specifications... 4 Safety Precautions and Tips... 5 Operations... 6 Installation... 7 Maintenance... 8-9 Troubleshooting...

More information

Dodge 24v ISBe

Dodge 24v ISBe BD SUPER B 2003-2004 Dodge 24v ISBe (Non 600 motors) Part # 1045230 PLEASE READ ALL INSTRUCTIONS BEFORE INSTALLATION This turbo system is not compatible with an AFE intake system WITHOUT MODIFICATIONS.

More information

MACHINES / RECLAIMS WITH DUST BAG

MACHINES / RECLAIMS WITH DUST BAG WARNING SET-UP INSTRUCTIONS MACHINES / RECLAIMS WITH DUST BAG *** READ BEFORE OPERATING EQUIPMENT *** 1. Remove plastic from machine. 2. Remove lag bolts from each of the four legs, then remove machine

More information

Mechanical Lift Pump System

Mechanical Lift Pump System Installation Manual FUEL BOSS Mechanical LP P/N FB-03045 2003 2004.5 DODGE CUMMINS FUEL BOSS Mechanical Lift Pump System Installation Instructions Fuel Boss LP System p/n FB-03045 PLEASE READ ALL INSTRUCTIONS

More information

Raydot LLC 24 Actuator (115 VOLT)

Raydot LLC 24 Actuator (115 VOLT) Installation, Operation & Parts Manual Read carefully the information provided. Retain manual for future reference. Raydot LLC 24 Actuator (115 VOLT) 145 Jackson Ave. S. Cokato, MN 55321-USA (320) 286-2103

More information

A/C PRESSURE MONITOR INSTALLATION INSTRUCTIONS SYSTEM OPERATION GREEN INDICATOR LIGHT

A/C PRESSURE MONITOR INSTALLATION INSTRUCTIONS SYSTEM OPERATION GREEN INDICATOR LIGHT A/C PRESSURE MONITOR INSTALLATION INSTRUCTIONS Do not attempt to clean or inspect anything while the engine is running. Cleaning and inspection must be done by a certified mechanic. All A/C service must

More information

RENEGADE SLATE BUMPER POOL TABLE ASSEMBLY INSTRUCTIONS

RENEGADE SLATE BUMPER POOL TABLE ASSEMBLY INSTRUCTIONS RENEGADE SLATE BUMPER POOL TABLE ASSEMBLY INSTRUCTIONS NG2404PG THANK YOU! Thank you for purchasing this product. We work around the clock and around the globe to ensure that our products maintain the

More information

MULTI-STAGE FILTRATION SYSTEM INSTALLATION INSTRUCTIONS

MULTI-STAGE FILTRATION SYSTEM INSTALLATION INSTRUCTIONS MULTI-STAGE FILTRATION SYSTEM INSTALLATION INSTRUCTIONS Model #: 30101 Model #: 30102 Replacement Cartridge INSTALLATION GUIDE ABOUT THIS SYSTEM Congratulations on your purchase of the 30101 Multi-Stage

More information

Penguin Gentoo 600B Cordless Sprayer User s Manual

Penguin Gentoo 600B Cordless Sprayer User s Manual Penguin Gentoo 600B Cordless Sprayer User s Manual Please read before use. Serial Number: Date of Purchase: Distributor: LIMITED WARRANTY POLICY Masterclean Products, LLC endeavors to provide high quality

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Safety Notices... 1... 3 Specifications... 3 General... 3 Electrical... 3 Hydraulic Connections... 3 Components... 4 Assembly... 4 Implement Installation... 7 Hydraulic Connections... 9 Closed-Center Hydraulics...

More information

HURRICANE 54-IN FOOSBALL TABLE ASSEMBLY INSTRUCTIONS

HURRICANE 54-IN FOOSBALL TABLE ASSEMBLY INSTRUCTIONS HURRICANE 54-IN FOOSBALL TABLE ASSEMBLY INSTRUCTIONS Please Do Not Hesitate to Contact Our Consumer Hotline at 800-759-0977 with Any Questions That May Arise During Assembly or Use of This Product! NG1033F

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual IOM-HS-QTColdBevMax Installation, Operation and Maintenance Manual QT TM Cold Bev Max TM Models: QTCLDBMX-1S-.5M, QTCLDBMX-2S-.5M, QTCLDBMX-3S-.5M, QTCLDBMX-4S-.5M, QTCLDBMX-5S-.5M Tested and Certified

More information

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Before installation, these instructions must be read carefully and understood. PRODUCT WARRANTY Emerson warrants its Penberthy products as designed and manufactured to be free of defects in the material

More information

ReelGreen RG20 Instruction Manual For Operation and Maintenance

ReelGreen RG20 Instruction Manual For Operation and Maintenance ReelGreen RG20 Instruction Manual For Operation and Maintenance BigSprinkler.com 15250 Sunshine Rd. Yukon, OK. 73099 800-373-9325 Introduction Thank you for purchasing a ReelGreen RG20 traveling sprinkler

More information

New & Improved VariFlo Plural Component Equipment. Low Pressure Polymer Dispensing Equipment

New & Improved VariFlo Plural Component Equipment. Low Pressure Polymer Dispensing Equipment New & Improved VariFlo Plural Component Equipment Low Pressure Polymer Dispensing Equipment Table of Contents Page One Page Two Page Three Page Four Page Five Page Six Page Seven Page Eight Page Nine Page

More information

DEMA MODELS 606T INSTALLATION INSTRUCTIONS

DEMA MODELS 606T INSTALLATION INSTRUCTIONS I. PARTS: A. Select-O-Spray Assembly B. 2 Pcs. Foot Strainers & 1/4" ID Tubing C. 4 Pcs. Mounting Screws & Anchors D. 1 Pc. 100-15K Metering Tip Kit TABLE 1 Hose I.D. 3/8" 1/2" 5/8" Max. Length 15 ft.

More information

SOLAR DASH CHARGING SYSTEM USER GUIDE

SOLAR DASH CHARGING SYSTEM USER GUIDE SOLAR DASH CHARGING SYSTEM Doc 1.01 INST049 INSTALLATION STEP 1 Place 20 watt solar panel in the dash of the vehicle facing up. Note: For ideal results position the vehicle in a manner in which the solar

More information

24 Linear Actuator 115 Volts A.C. (Cat. # C430A)

24 Linear Actuator 115 Volts A.C. (Cat. # C430A) Installation, Operation & Parts Manual Read carefully the information provided. Retain manual for future reference. 24 Linear Actuator 115 Volts A.C. (Cat. # C430A) Page 1 of 8 IS10007.doc 11/15/06 IMPORTANT!

More information

Installation Guide for O-SO PURE s Mineral Mizer

Installation Guide for O-SO PURE s Mineral Mizer Installation Guide for O-SO PURE s Mineral Mizer Installation Guide for Mineral Mizer Before you begin 1. The main components to identify include: the and its associated DI Storage Tank and RED faucet.

More information

INSTALLATION INSTRUCTION & OWNER S MANUAL

INSTALLATION INSTRUCTION & OWNER S MANUAL CS-2500 & CS-2500P Water Filtration System INSTALLATION INSTRUCTION & OWNER S MANUAL Ver 1.2 All Rights Reserved APEC Water Systems Please keep this Owner s Manual for future reference. It contains useful

More information

Installation, Operation, Repair and Parts Manual

Installation, Operation, Repair and Parts Manual Self-Priming Adaptor Form L-1516 (3-08) Installation, Operation, Repair and Parts Manual Description Self-priming adaptor (SPA) is a low pressure tank that provides air separation from the liquid being

More information

HUSTLER 7' & 8' POOL TABLE ASSEMBLY INSTRUCTIONS

HUSTLER 7' & 8' POOL TABLE ASSEMBLY INSTRUCTIONS HUSTLER 7' & 8' POOL TABLE ASSEMBLY INSTRUCTIONS NG2515PB/NG2520PB THANK YOU! Thank you for purchasing this product. We work around the clock and around the globe to ensure that our products maintain the

More information

Model , Series A 9 in. (23 cm) roller frame with 45 angle and 12 in. reach 1/2 in. (13 mm) nap roller cover

Model , Series A 9 in. (23 cm) roller frame with 45 angle and 12 in. reach 1/2 in. (13 mm) nap roller cover Operating Instructions 309899 Rev. A This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. INSTRUCTIONS Manufactured by Model 246818, Series A 9 in. (23 cm) roller frame

More information

SIDEKICK TABLETOP SOCCER ASSEMBLY INSTRUCTIONS

SIDEKICK TABLETOP SOCCER ASSEMBLY INSTRUCTIONS SIDEKICK TABLETOP SOCCER ASSEMBLY INSTRUCTIONS NG1028T3 THANK YOU! Thank you for purchasing this product. We work around the clock and around the globe to ensure that our products maintain the highest

More information

Spray Nozzle Adapters

Spray Nozzle Adapters INSTRUCTIONS-PARTS LIST 306 788 INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. First choice when quality counts. Rev. G Supersedes Rev. F DIRECTIONAL

More information

DEMA SPRAY CLEAN DISPENSERS MODEL 605T INSTALLATION INSTRUCTION

DEMA SPRAY CLEAN DISPENSERS MODEL 605T INSTALLATION INSTRUCTION The 605T Spray Clean Dispenser is used in any application where a chemical product must be sprayed or foamed without the use of compressed air or a high pressure pump. City water pressure and optional

More information

Fuel Pressure Regulator Kit PART# - RY12040-RRFPR-6S5

Fuel Pressure Regulator Kit PART# - RY12040-RRFPR-6S5 APPLICATION(S): Yamaha FX-SHO, FZR & FZS Fuel Pressure Regulator Kit PART# - RY12040-RRFPR-6S5 We strongly recommend the use of a service manual to familiarize yourself with the various components and

More information

GETZ EQUIPMENT INNOVATORS PART NO.: 3G59419 MODEL: BV 101 P PNEUMATIC BELT VISE WITH EXTENDED BELT & ROLLER

GETZ EQUIPMENT INNOVATORS PART NO.: 3G59419 MODEL: BV 101 P PNEUMATIC BELT VISE WITH EXTENDED BELT & ROLLER GETZ EQUIPMENT INNOVATORS PART NO.: 3G59419 MODEL: BV 101 P PNEUMATIC BELT VISE WITH EXTENDED BELT & ROLLER 2320 Lakecrest Drive, Pekin IL 61554 PH. (888) 747-4389 Fax (309) 495-0625 Website: www.getzequipment.com

More information

Open Display Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

Open Display Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment! Turbo Air Speed up the Pace of Innovation CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Open Display Merchandiser Installation and Operation Manual Please read this manual completely

More information

INSTRUCTIONS PARTS LIST This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE

INSTRUCTIONS PARTS LIST This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE INSTRUCTIONS PARTS LIST 308 493 This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE Rev. A Second Gun Hose Kit 100 psi (6.9 bar) Maximum Working Pressure These kits include

More information

MAVERICK 7' POOL TABLE WITH TABLE TENNIS ASSEMBLY INSTRUCTIONS

MAVERICK 7' POOL TABLE WITH TABLE TENNIS ASSEMBLY INSTRUCTIONS MAVERICK 7' POOL TABLE WITH ASSEMBLY INSTRUCTIONS NG1023 THANK YOU! Thank you for purchasing this product. We work around the clock and around the globe to ensure that our products maintain the highest

More information

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5 MODELS 282050, 282716 & 283513 AIR OPERATED CHASSIS PUMP SERIES A OWNER/OPERATOR MANUAL SPECIFICATIONS Airmotor effective dia. in. 2.5 Airinlet Material outlet 1/4 NPTF 1/4 NPTF Liquid to Air Pressure

More information

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases Blue Air Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases Please read this manual completely before installing or operating this unit! BACB53 BACB71 BACB74 BACB83 BACB86 BACB96

More information

OWNERS MANUAL HF4263

OWNERS MANUAL HF4263 OWNERS MANUAL HF4263 ADJUSTABLE AB / BACK HYPER BENCH Note: Both Serial Number and Model Number are Required when Ordering Parts RECORD SERIAL NUMBER HERE CATALOG NUMBER 0805-000 Customer Service (800)

More information

Items # and #

Items # and # D I S P E N S E R T E C H N I C A L M A N U A L Items #91160-00 and #91161-00 1. System Description... 1 2. Equipment Included with the Green Earth II XL System... 2 3. Components Included with Green Earth

More information

AQUA-LAB HD/XD CHEMICAL DISPENSING SYSTEM. User Manual REV F revf0917

AQUA-LAB HD/XD CHEMICAL DISPENSING SYSTEM. User Manual REV F revf0917 AQUA-LAB HD/XD CHEMICAL DISPENSING SYSTEM User Manual REV F 4000087 revf0917 Hydra-Flex, Hydra-Flex, Inc. 2017 Inc. 2017 Page 1 TABLE OF CONTENTS Specifications 3 Layout Drawing 4 Panel Diagram 5 Estimated

More information

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

Reach ins, Freeezers & Refrigerators Installation & Operation Manual Reach ins, Freeezers & Refrigerators Installation & Operation Manual BSR23 BSF23 BSR49 BSF49 BSR72 BSF72 IMPORTANT SAFETY INSTRUCTIONS (SAVE THESE INSTRUCTIONS) Visit us on the web at www.blueairinc.com

More information

BD SUPER B SPECIAL Dodge 5.9L Cummins 24v ISB

BD SUPER B SPECIAL Dodge 5.9L Cummins 24v ISB 1 This turbo is intended for high performance applications and is not to be used for towing applications BD SUPER B SPECIAL 1994-2002 Dodge 5.9L Cummins 24v ISB Part# 1045120 PLEASE READ ALL INSTRUCTIONS

More information

23200 Navigator Dilution Control System 4 Button Model (NAV 4)

23200 Navigator Dilution Control System 4 Button Model (NAV 4) 23200 Navigator Dilution Control System 4 Button Model (NAV 4) Overview The NAV 4 Chemical Dilution Control System accurately dilutes cleaning chemicals from cleaning concentrate product. It is a closed

More information

CORE BREAKER MODEL 690 & 930 OPERATOR'S MANUAL AND PARTS BOOK

CORE BREAKER MODEL 690 & 930 OPERATOR'S MANUAL AND PARTS BOOK AgriMetalINC. CORE BREAKER MODEL 690 & 930 OPERATOR'S MANUAL AND PARTS BOOK AGRIMETAL INC. CORE BREAKER WARRANTY AgriMetal Incorporated (AgriMetal) warrants the new Core Breaker to be free from defects

More information

INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE ACTUATOR MANIFOLD

INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE ACTUATOR MANIFOLD INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE B-3724M ACTUATOR MANIFOLD MIDLAND MANUFACTURING CORP. 7733 Gross Point Road Skokie, Illinois 60077 Phone (847) 677-0333 FAX (847) 677-0138 WEBSITE

More information

RB72-3 HD Flush Mounted Directional Traffic Spikes Installation and Operating Precautions

RB72-3 HD Flush Mounted Directional Traffic Spikes Installation and Operating Precautions RB723 HD Flush Mounted Directional Traffic Spikes Installation and Operating Precautions 1. Install the Directional Traffic Controller perpendicular to the flow of traffic. If vehicles cross the controller

More information

OWNERS MANUAL HF4261

OWNERS MANUAL HF4261 OWNERS MANUAL HF4261 ADJUSTABLE AB BENCH Note: Both Serial Number and Model Number are Required when Ordering Parts RECORD SERIAL NUMBER HERE CATALOG NUMBER 0905-000 Customer Service (800) 548-5438 (858)

More information

L DODGE CUMMINS Maximizer System

L DODGE CUMMINS Maximizer System Installation Manual P/N 07509MAX 2007.5-09 6.7L DODGE CUMMINS Maximizer System Installation Instructions P/N 07509MAX GDP Big Line Kit Installation PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

More information

OWNERS MANUAL HF4550 PREACHER CURL. Customer Service (800) (858) Fax (858) RECORD SERIAL NUMBER HERE

OWNERS MANUAL HF4550 PREACHER CURL. Customer Service (800) (858) Fax (858) RECORD SERIAL NUMBER HERE OWNERS MANUAL HF4550 PREACHER CURL Note: Both Serial Number and Model Number are Required when Ordering Parts RECORD SERIAL NUMBER HERE CATALOG NUMBER 0805-001 Customer Service (800) 548-5438 (858) 578-7676

More information

DEMA SPRAY STATION II MODEL 606T-2 INSTALLATION INSTRUCTIONS

DEMA SPRAY STATION II MODEL 606T-2 INSTALLATION INSTRUCTIONS The 0T-2 Spray Station II Dispensers are used in any application where a chemical product must be sprayed or foamed without the use of compressed air or a high pressure pump. City water pressure and optional

More information

DP DIAPHRAGM PUMP Parts & Instruction Manual

DP DIAPHRAGM PUMP Parts & Instruction Manual DP-392.1 DIAPHRAGM PUMP Parts & Instruction Manual Price $10.00 CDS-JOHN BLUE COMPANY DIVISION OF ADVANCED SYSTEMS TECHNOLOGY, INC. 290 Pinehurst Drive Huntsville, Alabama 35806 P. O. Box 1607 Huntsville,

More information

PLAYOFF 48" FOOSBALL TABLE ASSEMBLY INSTRUCTIONS

PLAYOFF 48 FOOSBALL TABLE ASSEMBLY INSTRUCTIONS PLAYOFF 48" FOOSBALL TABLE ASSEMBLY INSTRUCTIONS NG1031F THANK YOU! Thank you for purchasing this product. We work around the clock and around the globe to ensure that our products maintain the highest

More information

PART NUMBER: F-706RLSS REVOLUTION LIFT: SLING-SEAT OPTION

PART NUMBER: F-706RLSS REVOLUTION LIFT: SLING-SEAT OPTION PART NUMBER: F-706RLSS REVOLUTION LIFT: SLING-SEAT OPTION 500 LB. [227 kg] MAXIMUM CAPACITY MANDATORY LEAVE THIS MANUAL WITH LIFT OWNER - WARNING- IMPORTANT SAFETY INSTRUCTIONS 1. READ AND FOLLOW ALL INSTRUCTIONS.

More information

OWNERS MANUAL HF PAIR VERTICAL DUMBBELL RACK. Customer Service (800) (858) Fax (858) RECORD SERIAL NUMBER HERE

OWNERS MANUAL HF PAIR VERTICAL DUMBBELL RACK. Customer Service (800) (858) Fax (858) RECORD SERIAL NUMBER HERE OWNERS MANUAL HF4459 5 PAIR VERTICAL DUMBBELL RACK Note: Both Serial Number and Model Number are Required when Ordering Parts RECORD SERIAL NUMBER HERE CATALOG NUMBER 0605-000 Customer Service (800) 548-5438

More information

WATERBLAST HOSE REEL SYSTEM HWB HOSE REEL OPERATION AND MAINTENANCE MANUAL W A T E R J E T T O O L S

WATERBLAST HOSE REEL SYSTEM HWB HOSE REEL OPERATION AND MAINTENANCE MANUAL W A T E R J E T T O O L S WATERBLAST HOSE REEL SYSTEM HWB HOSE REEL OPERATION AND MAINTENANCE MANUAL W A T E R J E T T O O L S 466 S. SKYLANE DR. DURANGO, COLORADO 81303 970-259-2869 PHONE 970-259-2868 FAX www.stoneagetools.com

More information

OWNERS MANUAL HF

OWNERS MANUAL HF OWNERS MANUAL HF4461-48 HORIZONTAL DUMBBELL RACK Note: Both Serial Number and Model Number are Required when Ordering Parts RECORD SERIAL NUMBER HERE CATALOG NUMBER 1005-000 Customer Service (800) 548-5438

More information

*Please Note* All Instructions, Manuals, Extra Orifices, Adjustment Tools, Setting Charts, Etc. MUST BE GIVEN TO END USER!

*Please Note* All Instructions, Manuals, Extra Orifices, Adjustment Tools, Setting Charts, Etc. MUST BE GIVEN TO END USER! *Please Note* All Instructions, Manuals, Extra Orifices, Adjustment Tools, Setting Charts, Etc. MUST BE GIVEN TO END USER! JD1775 Exact Emerge 12 Row Starter Fertilizer Installation Instructions L&D Ag

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual IOM-HS-QTCubeMax Installation, Operation and Maintenance Manual QT TM Cube Max TM Models: QTCBMX-1S-1M, QTCBMX-2S-1M, QTCBMX-3S-1M, QTCBMX-4S-1M, QTCBMX-1L-1M, QTCBMX-2L-1M, QTCBMX-3L-1M, QTCBMX-4L-1M,

More information

Operator s Safety and Service Manual

Operator s Safety and Service Manual Operator s Safety and Service Manual Cordless Sprayer Model: H100AC ALL CHEMICALS SMK Industries, Inc. 12839 Carpenter Trail Carlisle, IA 50047 Phone: 515-202-0052 Copyright 2014, SMK Industries Inc Email:john@smksprayers.comWeb:

More information

Getz Equipment Innovators 450 lb Portable / Wheeled Unit Dry Chemical Fill System Part No: 3G0061/3G0063

Getz Equipment Innovators 450 lb Portable / Wheeled Unit Dry Chemical Fill System Part No: 3G0061/3G0063 Getz Equipment Innovators 450 lb Portable / Wheeled Unit Dry Chemical Fill System Part No: 3G0061/3G0063 1 Revised 4/12/17 2320 Lakecrest Drive, Pekin IL 61554 PH. (888) 747-4389 Fax (309) 495-0625 Website:

More information

AQUA-LAB HD/XD CHEMICAL DISPENSING SYSTEM. User Manual REV L revl1018

AQUA-LAB HD/XD CHEMICAL DISPENSING SYSTEM. User Manual REV L revl1018 AQUA-LAB HD/XD CHEMICAL DISPENSING SYSTEM User Manual REV L 000087 revl08 Hydra-Flex, Hydra-Flex, Inc. 08 Inc. 08 Page TABLE OF CONTENTS Specifications Layout Drawing Panel Diagram Estimated Installation

More information

Potentiometer Thrust Plate Kit (50421) Installation & Operator s Instruction Manual

Potentiometer Thrust Plate Kit (50421) Installation & Operator s Instruction Manual Potentiometer Thrust Plate Kit (0) Installation & Operator s Instruction Manual Thank You The employees of Chore-Time Equipment would like to thank you for your recent Chore-Time purchase. If a problem

More information

Owner s Guide. ca6154

Owner s Guide. ca6154 PROFESSIONAL SERIES Owner s Guide For Models: ca6154 Deluxe Vehicle Security and Remote Start System IMPORTANT NOTE: The operation of the Security and Convenience System as described in this manual is

More information

SOLUTION STATION Instruction Manual

SOLUTION STATION Instruction Manual SOLUTION STATION Instruction Manual WAXIE Sanitary Supply 9353 WAXIE Way San Diego, CA 92123 Phone: 800.995.4466 www.waxie.com TABLE OF CONTENTS Unpacking Instructions Disclaimer..... Warranty... Introduction...

More information

JET METER INSTRUCTIONS

JET METER INSTRUCTIONS UNPACKING Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing materials to arrive to you undamaged. If you do find an item that is broken

More information

MLS KICK-OFF TABLETOP SOCCER TABLE ASSEMBLY INSTRUCTIONS

MLS KICK-OFF TABLETOP SOCCER TABLE ASSEMBLY INSTRUCTIONS MLS KICK-OFF TABLETOP SOCCER TABLE ASSEMBLY INSTRUCTIONS NGD1028 1 THANK YOU! Thank you for your purchase of this Harvil product. We work around the clock and around the globe to ensure that Harvil products

More information