1 CENTRIFUGAL PUMP ZPD6-25*7 OPERATION & MAINTENANCE MANUAL HANGZHOU FLYING TECHNOLOGY CO., LTD.

2

3 CONTENTS 1. GENERAL (1) 2. NOMENCLATURE OF THE TYPE (1) 3. MAIN TECHNICAL SPECIFICATIONS RANGE (1) 4. STANDARD (1) 5. OUTSTANDING CHARACTERICS (1) 6. SERIES-DIAGRAM (3) 7. Pump Structure Diagram (4) 8. Pump performance curve and performance table (5) 9. Pump overall installation dimension diagram (6) 10. Assemble and disassemble of pump (7) 11. Installation of pump (8) 12. Pump starting, running and stopping (9-12) 13.Common faults and troubleshooting method of pump (13-14)

4 GENERAL With the typical structural features : in structure complete cancel traditional for balancing axial thrust balancing system, depend on the symmetrical layout of the impeller balanced axial force automatically, this innovation makes the multistage pumps with energy-saving and efficient, stable and reliable, less wearing parts, high reliability and significantly lower operation cost advantages, it is the best alternative to ordinary multistage centrifugal pump. NOMENCLATURE OF THE TYPE Model of pump: ZPD6-25*7 ZP: Automatic balance D: Horizontal multi-stage centrifugal water 25*7 : Head is 175m MAIN TECHNICAL SPECIFICATIONS RANGE Capacity: 6.3 cubic meters per hour Head: 175m Motor power: 11 kw Speed: 2950r/min Protection grade :IP55 Voltage:480V Standard 1.GB/T (Technical specifications for centrifugal pumps-class Ⅲ) 2.JB/T ( Multistage centrifugal pump type and basic parameters) Outstanding characteristics 1. High efficiency and energy saving: Advanced of hydraulic model, independent development, efficient energy saving products. Due to pump rotor without balance disc of wear and axis to pulse, impeller and guide leaves of on neutral are always in best State, not like general multilevel balance disc of wear, rotor parts move forward and appear efficiency clear fell. Besides without leak of balance water, volume loss has reduced. It improves running efficiency of pump in overall. And shaft power has been reduced. Compare with general multilevel pump efficiency, life average much 2%~3%. 2. The new structure: With the symmetric part of the impeller rotor part, symmetrical blade rotor at all levels the forces cancel each other out. Automatic balance of pump TOTAL 14 PAGES1 NO.(1 )

5 chamber huge axial thrust can be achieved without the balanced structure. It broke through the traditional structure of multistage pump. 3. New structure Unique throttling, pressure-relief devices and odd class balance device, which can also act as a secondary support role. 4. High reliability Symmetric layout of impeller make the axial thrust of the run equilibriumed, therefore, a balancing device that small gaps, high pressure drop, easy to wash, easy to wear is not needed. It makes the axial force on the pump wear and minimize the interference effect on the system to a minimum. 5. Good cavitation performance makes life longer : The optimization of the hydraulic and structure design, precision casting, reliable wear-resisting material, Part of the pump impeller type head with double suction structure. all these make the pump have good resistance and cavitation ability. Besides, depend on this, the machine runs smoothly, with low noise and long service life. 6. Mechanical seal reliability: The rotor part has no axial movement when pump starts and stops and works without axial pulse. It overcomes difficulty of poor sealing reliability which multistage pumps have been plagued by; 7. Wide application: Cancellation of small gaps balance dish makes it suitable for worse media properties than traditional multistage pumps structure. 8. Lower maintenance costs: Use of investment casting reduce the number of delicate parts and maintenance access. Besides, extend product lifes. A series of problems caused by assembling and disassembling are avoided and maintenance costs reduce. TOTAL 14 PAGES2 NO.(2 )

6 TOTAL 14 PAGES NO.(3)

7 TOTAL 14 PAGES NO.( 4 )

8 TOTAL 14 PAGES NO.( 5 )

9 TOTAL 14 PAGES NO.( 6 )

10 Assemble and disassemble of pump Assemble of pump The pump assembly and disassembly sequence generally in reverse order. Assembly quality affects the normal operation, the service life and performance parameters of the pump directly. Following points should be paid attention to when assemble: 1) Protect accuracy and surface roughness of the parts well. No bumps and scratches. Keep the sealant clean and fastening nails and bolts force uniform.; 2) Neutral of impeller outlet channel and guide vane inlet channel depends on axial dimensions of every part. As runner on neutral affects performance parameters of the pump directly, don t change the pump size freely. 3) Finished assemble of pump, before packing, hand turn the pump rotor to check the flexibility of rotor; 4) Inspection well, then install the packing. Note when disassembling pump 1) Stop according to order; 2) Liquid in the casing ( cooling water included) should be let out; Lubricating oil should let out if bearing parts with thin oil lubrication. 3) Removed the affiliated pipelines in order to disassemble pump, such as return pipe and so on. 4) Protect accuracy of the parts well, Pad the middle stage with pad while disassembling lever so that shaft won t be bent by middle stage. The disassembling step of the pump 1) After disassembled of the coupling, unscrew the bolt on the bearing gland, conjoined nuts between suction and bearing housing, the front bearing housing. 2) Unscrew the round nut on the shaft, then take off bearing inner ring, bearing gland and retaining collar in order. 3) Pad the middle stage with pad, unscrew the wear lever nut, inlet section and packing gland, packing ring and packing on the inlet section. 4) Disassemble the front stage impeller, flat key, forward guide vane, forward guide impeller, end-level forward guide vane, discharge stage, throttle and pressure relief devices in order. 5) Disassemble the end-level backward guide vane, end-level backward impeller, flat key, backward guide vane, backward impeller, after throttle and pressure relief devices in order. Note:the direction of guide vane and impeller. 6) Unscrew the nut between suction stage and end gland, take off the spindle, end gland and part on rear bearing housing. 7) Unscrew the nut between end gland and bearing housing, unscrew the gland packing, packing ring and packing on the end gland. TOTAL 14 PAGES7 NO.(7 )

11 8) Unscrew the nut on the bearing gland, disassemble shaft,small round nut, bearing cap in order. 9) The disassembling order of the pump is mainly the same for plain bearings except some difference during bearing parts. The installation of the pump In addition to general requirements, this type pump installation should pay attention to the following several points as well: 1) When installation of pump, foundation surface should be level. Check the baseplate and bolts loose or not after foundation of cement solidification. 2) After assemble motor, pump and the baseplate, pls carefully check the concentricity between the pump shaft and the motor shaft, ensure the two axis on the same horizontal line. 3) When Assembling motor and pump, guarantees the pump and motor coupling axial clearance value is 3 MM, the series pump no axial move. 4) The pump can only withstand the internal force, can not withstand any external force. Therefore, the suction line of the pump and pressure line should have its own bracket to avoid crush. 5) To pump D(P) MD(P) that for Mine industry contains combustible gases,explosion-proof motor with protection and explosion-proof mark should be used. TOTAL 14 PAGES8 NO.(8 )

12 Pump starting, running and stopping Start 1) before starting, turn the rotor to check its flexibility 2) Check if direction of rotation of motor and pump is same. 3) Open suction valve (if suction valve is available), Close gate valves of the export pipeline and pressure gauges cock to make pump full of liquid. Or use vacuum-system exhaust the air in suction line and pump. 4) Check the safety and tightness of joins bolt between pump and motor to make sure the pump is ready to start. 5) Start motor, after pump normal rotation, Open pressure gauges cock, Slowly open the outlet valve, until the pressure gauge pointer to the setting pressure( according to reading of pressure gauge control head of pump) Run 1) Balance of axial force by pump itself, so no balance pipe. To ensure the pump run normally, prohibit block up return pipe. 2) In the process of starting and running, must observe if instrument reading, heating in the bearings, packing leakage and temperature, vibration and the sound of the pump working correctly. Once Abnormal situation happened, should dealt with immediately. 3) Bearing temperature rise changes reflect quality of the pump assembly, Bearing temperature rise shall not be 35 higher than the ambient temperature and the highest wearing temperature shall not be higher than 75. 4) Worn condition of impeller,seal joint, impeller wear during running, guide vane,shaft sleeve, throttle and pressure relief devices should be regularly inspected, if excessive wear,they should be timely replacement Stop 1) Before stopping, close pressure gauges cock. Slowly close the outlet gate valve, close motor after closed outlet gate valve, close the Suction valve after pump stop (if suction valve is available) 2) If pumps stop for long time, should remove all bolts below suction stage, discharge TOTAL 14 PAGES NO( 9)

13 stage, secondary inlet section, discharge water and disassemble pump and clean and adding oil, packaging for standby TOTAL 14 PAGES NO( 10)

14 TOTAL 14 PAGES NO.( 11 )

15 1. MOTOR 2. PRESSURE GUAGE 3. OUTLET RODE 4. GATE 5. CHECK VALVE 6. EXPANSION JOINTS 7. WATER SHORT TUBE 8. PUMP 9. PUMP TRANSITION TUBE 10. VACUUM GUAGE 11. WATER PIPELINE 12. FILTER MESH 13. ANCHOR BOLT TOTAL 14 PAGES NO.(12 )

16 Common faults and troubleshooting method of pump No. DEFECTS PROBABLE CAUSE 1 Pump does not absorb water, pointer of pressure gauges and vacuum gauge vibrate violently, or vacuum gauge displays a high vacuum. 1. Pump filled with water is not enough 2. Leakage of pipes or gauges 3.Bottom valve not open 4. Suction pipe block up. 5. Suction height over RECOMMENDED REMEDIES 1. Pump water and exhaust gas 2. Tighten screw fasteners 3.Repair or replace the bottom valve 4. Cleaning suction pipe 5. Lower suction pipe height 2 Pump outlet water have Pressure, no flow or flows too less 1. Flow channel blockage, or bottom valve partially blocked 2. Pump rotation speed lower than a setting value 3. Total head higher than the pump design head 4. gas in pump 5. rotation direction of pump wrong 6. Parts wear, internal leak too large 1. Cleaning channel, or clear foreign matter on bottom valve 2. improve pump rotation speed 3.Increase pump grade or reduce pipeline loss 4. Inlet parts block up 5. Motor reconnect wiring 6. replace wearing parts 3 Motor current is too high 1. The system total head is much lower than the design of the pump head 2. Pipeline broke and leakage 3. Starts with export gate valves opening 4. Pump shaft and electric not concentric. 5. The rotating parts and fixed abrade 6. Bearing wearing. 7. The rotor imbalance and vibrates 8. Voltage is too low 4 Stuffing box leakage Packing smoke Packing short life 1. Pump shaft and electric not concentric 2. Shaft bends 3. The packing place sleeves damage Or packing installation wrong, packing model is wrong 4. impurity between packing and shaft sleeve 5 Pump vibrate or noise 1. Pump cavitate 2. Flow channel blockage or bottom valve partially blocked. 3. Pipeline rupture running water 4. Starts with export gate valves opening 1. Close gate valve to adjust or reduce pump series 2. Stop pump to clean pipeline 3. Close gate valve to restart. 4. Re-alignment to avoid the system force on the pump 5. Open pump to adjust 6. Replace bearing 7. Remove the rotor, do static and dynamic balance test. 8. Improve voltage 1. Re-alignment 2. Remove and correct shaft 3.Polish or replace sleeves repacking, uniform pressure Or replace packing. 4. Replace packing. 1. Reduce the geometry of the pump installation height, reduce the suction pipe resistance 2. clear channel or foot valve 3. Stop pump to clean pipeline TOTAL 14 PAGES NO.(13)

17 5.Pump shaft and electric not concentric, or shaft bends 6. Insufficient basis rigid 7. The rotating parts and fixed abrade. 8. Impeller defect 9. Too much or too little grease in bearing 10. Bearing wear or dirt there. 6 Bearing heating 1.Pump shaft and electric not concentric, or shaft bends 2. The rotating parts and fixed abrade. 3. Bearing wear or dirt or water there 4. Too much or too little grease in bearing. 7 The place such as the middle with surface leakage 1. The poles to bolts force not enough or force not balanced 2. The manufacturing precision of part(rough degree, beating or vertical degree) is not up to the design requirements, or residual force makes part deformation 3.Joint surface not clean or damage 4. Close gate valve to restart. 5. Re-alignment or repair or replace shaft 6. Reinforce foundation 7. Open pump to adjust 8. Replace impeller 9. Add moderate grease 10.Replace or clear bearing, pay attention to seal bearing 1.Re-alignment or repair or replace shaft. 2.Open pump to adjust 3. Add moderate grease 4.Replace or clear bearing, pay attention to seal bearing 1. To tighten the poles 2. Open pump to check 3. Repair joint surface TOTAL 14 PAGES NO.(14)

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Contents Section 1. General Observations... 2 2. Operation... 4 3. Control During Operation... 5 4. Trouble Shooting... 6 5. Maintenance... 7 Please

More information

NECO Pumping Systems

NECO Pumping Systems INSTALLATION OPERATION & MAINTENANCE INSTRUCTIONS For Your NECO Pumping Systems Fuel Oil Transfer System THIS COMPLETELY ASSEMBLED, TESTED, PACKAGED SYSTEM IS OF THE HIGHEST QUALITY AND DESIGN. TO OBTAIN

More information

PowerLink GW series Eddy Current Dynamometer User Manual

PowerLink GW series Eddy Current Dynamometer User Manual PowerLink GW series Eddy Current Dynamometer User Manual XiangYi (Hong Kong) Power Testing Instrument Co. Ltd. 0 GW Series Eddy Current Dynamometer User Manual Transport, Storage, use of environmental

More information

GMZ series Slurry Pump

GMZ series Slurry Pump GMZ series Slurry Pump OPERATION MANUAL HL Mud Cleaning Equipment Co.,Ltd Contents 1. Summarizing 2. Structural Drawing 3. Technical Parameters 4. Points for attention for assembly 5. Operation 6. Care

More information

The ELM Series Slurry Pump Installation and Operating Manual

The ELM Series Slurry Pump Installation and Operating Manual The ELM Series Slurry Pump Installation and Operating Manual Excellence Pump Industry Co., Ltd. SAFETY INFORMATION The following safety information relating to pump operation and maintenance should be

More information

ISO 9001 CERTIFIED COMPANY INDUSTRIAL PUMPS. Installation & Operational Manual For BACK-PULL-OUT PUMP

ISO 9001 CERTIFIED COMPANY INDUSTRIAL PUMPS. Installation & Operational Manual For BACK-PULL-OUT PUMP ISO 9001 CETIFIE COPANY Installation & Operational anual For BACK--OT P EX Assembly isassembly Erection Starting unning Stopping and aintenance Cautions in use of echanical Seal Stuffing Box and Packing

More information

Service Manual #67. Installation and Service Instructions 6000, 7000 & 8000 Series Magnetically Coupled Pumps

Service Manual #67. Installation and Service Instructions 6000, 7000 & 8000 Series Magnetically Coupled Pumps Service Manual #67 Installation and Service Instructions 6000, 7000 & 8000 Series Magnetically Coupled Pumps Table of Contents Section Description Page 1 General Description 4 2 The Pumping Principle 5

More information

INSTRUCTION MANUAL INTERNAL GEAR PUMP TITAN G-4124A SERIES=> FLANGED TITAN G-124A SERIES => FLANGED MODELS:

INSTRUCTION MANUAL INTERNAL GEAR PUMP TITAN G-4124A SERIES=> FLANGED TITAN G-124A SERIES => FLANGED MODELS: INSTRUCTION MANUAL INTERNAL GEAR PUMP TITAN G-4124A SERIES=> FLANGED TITAN G-124A SERIES => FLANGED MODELS: G-H, G-HL, G-K, G-KK, G-L, G-LQ, G-LL, GLS, G-Q, G-QS 1 Contents Maintenance Thrust bearing adjustment

More information

HORIZONTAL SPLIT CASING PUMP

HORIZONTAL SPLIT CASING PUMP OPERATION & MAINTENANCE MANUAL HORIZONTAL SPLIT CASING A Mark of Quality CROSS SECTION DRAWING No. DESCRIPTION MATERIAL 01 1/4 BSP PLUG BRASS 02 LOWER HOUSING C. I. IS-210, FG260 03 IMPELLER C. I. / G.

More information

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS Installation and Operating Instructions VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS Models 1, 3, 5, 10, 15, 20, 32, 45, 64, 90 1. Model numbering and nameplate format 1.1 Model numbering Example: SBI / SBN

More information

Operating & Installation Manual

Operating & Installation Manual Operating & Installation Manual (ZH1.5kw wind turbine system) Company Name:YUEQING ZONHAN WINDPOWER CO.,LTD. Address:NO.195,Chengxi Road,Yuecheng,Yueqing,Zhejiang,P.R.China Zip Code:325600 Tel:86-577-62529820

More information

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS Installation and Operating Instructions VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS Models 1, 3, 5, 10, 15, 20, 32, 45, 64, 90, 120, 150 1. Model numbering and nameplate format 1.1 Model numbering Example:

More information

Water Treatment Plant Maintenance Considerations. Operation and Maintenance. Types of Maintenance 5/1/15

Water Treatment Plant Maintenance Considerations. Operation and Maintenance. Types of Maintenance 5/1/15 Water Treatment Plant Maintenance 1 Operation and Maintenance Purpose of O&M maintain design functionality (capacity) restore the system components to their original condition and thus functionality. Effective

More information

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING VACUUM PUMPS

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING VACUUM PUMPS (Rev. 2.0_10-2010) DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING VACUUM PUMPS TRVK 2003 to 5003 TRSK 2005 to 5005 INTRODUCTION These instructions are for the maintenance staff in case of repair

More information

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25 V acuum Pumps Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25 www.republicsales.com Revised 10.14 2014 Republic Sales & Manufacturing Single Stage Rotary Vane Vacuum

More information

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

SLR / SLR-S/N. Instruction Manual. Walrus America Inc SLR / SLR-S/N Instruction Manual Walrus America Inc 1. Installation and Connection 1.1. Pump Installation The pump should be sited in a well ventilated and frost-free position. The distance between pumps-motors

More information

MAINTENANCE AND REPAIR INSTRUCTIONS

MAINTENANCE AND REPAIR INSTRUCTIONS MAINTENANCE AND REPAIR INSTRUCTIONS TYPE TH PUMPS Peerless Pump Company Indianapolis IN, 46207-7026 4849357 TABLE OF CONTENTS Maintenance Page 1 & 2 Disassembly Page 5 & 6 Impeller Clearance 3 Reassembly

More information

Operating Manual for Rotary Gear Pumps CMI, S.A. (Mendaro, Guipuzkoa, Spain)

Operating Manual for Rotary Gear Pumps CMI, S.A. (Mendaro, Guipuzkoa, Spain) Operating Manual for Rotary Gear Pumps CMI, S.A. (Mendaro, Guipuzkoa, Spain) Pre-Installation 1. Choose a location that is easily accessible for pump servicing. Ensure adequate electrical service is available.

More information

INSTALLATION AND SERVICE INSTRUCTIONS FOR 1008 AND 1010 SERIES PUMPS

INSTALLATION AND SERVICE INSTRUCTIONS FOR 1008 AND 1010 SERIES PUMPS Service Instruction No. 11 INSTALLATION AND SERVICE INSTRUCTIONS FOR 1008 AND 1010 SERIES PUMPS GENERAL DESCRIPTION Pumping Principles Page 2 INSTALLATION Location Page 3 Proper Installation Page 3 Filter

More information

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-40 RX-63 RX-100

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-40 RX-63 RX-100 V acuum Pumps Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-40 RX-63 RX-100 www.republicsales.com Revised 02.15 2015 Republic Sales & Manufacturing Single Stage Rotary Vane

More information

ABS Dry Installed Waste Water Pumps Series FR

ABS Dry Installed Waste Water Pumps Series FR A Operating Instruction 3 ABS Dry Installed Waste Water Pumps Series FR Shaft Seal Close-coupled and Bearing Assemblies 3R, 4R, 5R, 5F and 6F! Observe for hazardous liquids that there can be liquid left

More information

PROJ. NO SECTION HYDRONIC PUMPS

PROJ. NO SECTION HYDRONIC PUMPS SECTION 23 21 23 HYDRONIC PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

GENESIS COUPE(BK) > 2010 > G 3.8 DOHC > Steering System

GENESIS COUPE(BK) > 2010 > G 3.8 DOHC > Steering System GENESIS COUPE(BK) > 2010 > G 3.8 DOHC > Steering System Steering System > General Information > Specifications Specifications Steering gear Oil pump Steering angle Power steering oil Item Specification

More information

Bearings. Rolling-contact Bearings

Bearings. Rolling-contact Bearings Bearings A bearing is a mechanical element that limits relative motion to only the desired motion and at the same time it reduces the frictional resistance to the desired motion. Depending on the design

More information

There are few directions to maintain and operate the valves which are explained below for each valve.

There are few directions to maintain and operate the valves which are explained below for each valve. There are few directions to maintain and operate the valves which are explained below for each valve. MAINTENANCE INSTRUCTION FOR SLUICE GATE AS PER IS:3042/IS:13349 1. Frame (Serial No.- 2 of Drawing)

More information

ENGINE LUBRICATION & COOLING SYSTEMS SECTIONLC CONTENTS. ENGINE LUBRICATION SYSTEM...2 Precautions...2

ENGINE LUBRICATION & COOLING SYSTEMS SECTIONLC CONTENTS. ENGINE LUBRICATION SYSTEM...2 Precautions...2 ENGINE LUBRICATION & COOLING SYSTEMS SECTIONLC CONTENTS ENGINE LUBRICATION SYSTEM...2 Precautions...2 LIQUID GASKET APPLICATION PROCEDURE...2 Preparation...2 SPECIAL SERVICE TOOLS...2 Lubrication Circuit...3

More information

TECHNICAL SERVICE MANUAL INSTALLATION, START UP, TROUBLESHOOTING, SERIES SG-04, SG-05 & SG-07 spur gear PUMPS

TECHNICAL SERVICE MANUAL INSTALLATION, START UP, TROUBLESHOOTING, SERIES SG-04, SG-05 & SG-07 spur gear PUMPS Electronic copies of the most current TSM issue can be found on the Viking Pump website at www.vikingpump.com TECHNICAL SERVICE MANUAL SECTION TSM 340 PAGE 1 OF 10 ISSUE G INSTALLATION, START UP, TROUBLESHOOTING,

More information

barmesapumps.com CD SERIES RPM Installation, Operation & Maintenance Manual End-Suction Centrifugal Stainless Steel Pumps

barmesapumps.com CD SERIES RPM Installation, Operation & Maintenance Manual End-Suction Centrifugal Stainless Steel Pumps Installation, Operation & Maintenance Manual End-Suction Centrifugal Stainless Steel Pumps CD SERIES 1-3 HP @ 3450 RPM IMPORTANT! - Read all instructions in this manual before operating or servicing a

More information

Operation Manual Model: PPSSS Submersible Slurry Pump

Operation Manual Model: PPSSS Submersible Slurry Pump ABN 17 154 031 802 21 Ginger St, Paget Mackay Qld Australia 4740 PO Box 5709, Mackay Mail Centre Qld Australia 4741 Ph: +61 07 4998 5070 Fax: +61 07 4952 1944 Mobile: +61 0409 827 290 Email: admin@pricepumpsaustralia.com.au

More information

3M Overhaul Service Kit

3M Overhaul Service Kit SERVICE INSTRUCTIONS FOR 3M 12,000 RPM 3 in. (77 mm) RANDOM ORBITAL SANDERS 3M Overhaul Service Kit The part number 20346, 3M Overhaul Service Kit, contains all the replacement parts that naturally wear

More information

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX: TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: +353 66 7121911 FAX: +353 66 7124503 e-mail: sales@tillotson.ie HR SERIES SERVICE MANUAL INTRODUCTION Tillotson has developed

More information

Heavy duty slurry pumps

Heavy duty slurry pumps USERS MANUAL Heavy duty slurry pumps TOYO PUMPS EUROPE Edition 27.07.2007 SAFETY INSTRUCTIONS TOYO PUMPS EUROPE Users manual for Toyo pumps type «DP..-6 30~40HP» This users manual will help you to maintain

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 23 2123 - PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

FACF AUTOMATIC CAPSULE FILLER SERIES USER MANUAL

FACF AUTOMATIC CAPSULE FILLER SERIES USER MANUAL FACF AUTOMATIC CAPSULE FILLER SERIES USER MANUAL LFA Tablet Presses is a trading name of LFA Machines Oxford LTD All of the content in this document is covered by copyright CONTENTS Page 1. Introduction

More information

PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS

PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS TO OBTAIN THE BEST PERFORMANCE FROM YOUR PROMAG SR PUMP, PLEASE READ THE MANUAL CAREFULLY. Failure to

More information

Table of Contents Illustrations

Table of Contents Illustrations Principals of Operation Inspection & Troubleshooting Principles of Operation Inspection & Troubleshooting Form No. F 1031 Section 1000 Issue Date 09/19/94 Rev. Date 02/07/07 Table of Contents Illustrations

More information

k. Components not properly adjusted. Refer to machine technical manual for proper adjustment of components.

k. Components not properly adjusted. Refer to machine technical manual for proper adjustment of components. General Troubleshooting Charts General Troubleshooting Charts Use the charts on the following pages to help in listing all the possible causes of trouble when you begin diagnosing and testing of a machine.

More information

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery Table 6-1. and solutions with pump operations No Fluid Delivery Fluid level in the reservoir is low. Oil intake pipe or inlet filter is plugged. Air leak in the inlet line prevents priming or causes noise

More information

PROCESS PUMPS (INDIA) PVT LTD

PROCESS PUMPS (INDIA) PVT LTD MANUAL: - M12 HORIZONTAL BPO METALLIC PUMP WITH GLAND PACKING (GROUP- III & IV) INSTALLATION, OPERATION AND MAINTENANCE MANUAL PROCESS PUMPS (INDIA) PVT LTD Plot No.86, III Phase, Peenya Industrial Area,

More information

PROCESS PUMPS (INDIA) PVT LTD

PROCESS PUMPS (INDIA) PVT LTD HYDRODYNAMIC SEAL NON METALLIC PUMP INSTALLATION, OPERATION AND MAINTENANCE MANUAL PROCESS PUMPS (INDIA) PVT LTD Plot No.86, III Phase, Peenya Industrial Area, Bangalore 560058 Phone: 91-80-28395327/28

More information

Principals of Operation... 1 Rotary Vane Priming Pump VPE and VPES... 2 Rotary Vane Priming Pump VPO and VPOS Priming Valve...

Principals of Operation... 1 Rotary Vane Priming Pump VPE and VPES... 2 Rotary Vane Priming Pump VPO and VPOS Priming Valve... Priming Systems Installation Priming Systems Operation & Maintenance Form No. F 1031 Section 2312 Issue Date 10/07/94 Rev. Date 02/27/06 Table of Contents Illustrations Principals of Operation...........................

More information

HM WIND TURBINE. Operation Manual. **Please read the manual carefully before using **

HM WIND TURBINE. Operation Manual. **Please read the manual carefully before using ** HM4.0-3000 WIND TURBINE Operation Manual **Please read the manual carefully before using ** - 1 - HM4.0-3KW operation manual.doc 1. The aim of Application Use wind energy to generate electricity and charge

More information

Installation, Operation and Maintenance Manual SCP/SFP SELF PRIMING PUMPS

Installation, Operation and Maintenance Manual SCP/SFP SELF PRIMING PUMPS Installation, Operation and Maintenance Manual SCP/SFP SELF PRIMING PUMPS IMPORTANT - WARRANTY CLAUSE ROTECH PUMPS: Pumps manufactured & assembled by Rotech, are covered by warranty for free of manufacturing

More information

END SUCTION CENTRIFUGAL PUMPS

END SUCTION CENTRIFUGAL PUMPS OWNERS GUIDE TO INSTALLATION AND OPERATION FW000 009 Supersedes 07 END SUCTION CENTRIFUGAL PUMPS READ THESE INSTRUCTIONS CAREFULLY Read these installation instructions in detail before installing your

More information

SPECIFY THE RIGHT HOT OIL PUMP FOR YOUR APPLICATION

SPECIFY THE RIGHT HOT OIL PUMP FOR YOUR APPLICATION SPECIFY THE RIGHT HOT OIL PUMP FOR YOUR APPLICATION Hot oil pumps are used in a range of industries, with their main user being the heat transfer oil customer. Often, oil temperatures will exceed 500 F

More information

TECHNICAL SERVICE MANUAL HEAVY-DUTY BRACKET MOUNTED PUMPS SERIES 120 and SERIES 124 MODELS J, K, KK, L, LQ, LL AND LM

TECHNICAL SERVICE MANUAL HEAVY-DUTY BRACKET MOUNTED PUMPS SERIES 120 and SERIES 124 MODELS J, K, KK, L, LQ, LL AND LM TECHNICAL SERVICE MANUAL HEAVY-DUTY BRACKET MOUNTED PUMPS SERIES 120 and SERIES 124 MODELS J, K, KK, L, LQ, LL AND LM SECTION 3 BULLETIN TSM-120-124-V ISSUE B-2005 CONTENTS Special Information 2 Maintenance

More information

- click here for pricing and ordering

- click here for pricing and ordering www.pumpagents.com - click here for pricing and ordering No. 51-038 Mar. 01, 2006 MD-40R MD-40RX MD-40RZ(-5) Item Description Q'ty Material Part No. Part No. Part No. 1 Front Casing Unit 1 GFRPP+PTFE MD0053

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS CS Series Pressed Stainless Steel Centrifugal Pump Please pass these instructions on to the operator of this equipment. Introduction Davey CS centrifugal pumps

More information

3M Overhaul Service Kit

3M Overhaul Service Kit SERVICE INSTRUCTIONS FOR 3M 12,000 RPM 5 in. (127 mm) and 6 in. (150 mm) RANDOM ORBITAL SANDERS 3M Overhaul Service Kit The part number 20347, 3M Overhaul Service Kit, contains all the replacement parts

More information

OPERATION MANUAL INTERNAL GEAR PUMP. Models: NG-H, NG-HL, NG-K, NG-KK, NG-L, NG-LQ, NG-LL, NG-LS, NG-Q, NG-QS. Tel: Fax:

OPERATION MANUAL INTERNAL GEAR PUMP. Models: NG-H, NG-HL, NG-K, NG-KK, NG-L, NG-LQ, NG-LL, NG-LS, NG-Q, NG-QS. Tel: Fax: OPERATION MANUAL INTERNAL GEAR PUMP Models: NG-H, NG-HL, NG-K, NG-KK, NG-L, NG-LQ, NG-LL, NG-LS, NG-Q, NG-QS. 1 Contents Pump Designation System Maintenance Thrust bearing adjustment Pressure Relief Valve

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS When this Jack leaves the factory, the air release plug is closed to prevent the oil being spilled when the Jack is in transit. To simplify the air-venting of the oil chamber, a

More information

A Series 50HZ. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001

A Series 50HZ. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001 A - Series A Series ISO-9 AVC/AVI/AVS HZ Evak Pump Technology Corp. No., Zhongshan Rd., Qingshui Township, Taichung County, Taiwan. Tel : +-- Fax: +--9 www.evak-pumps.com Vol. PIAV- A-Series Index Multistage

More information

1. SPECIFICATION. Altitude of motor installation. Information: Resistance and temperature specifications of the PTC thermistor / posistor/.

1. SPECIFICATION. Altitude of motor installation. Information: Resistance and temperature specifications of the PTC thermistor / posistor/. 1. SPECIFICATION 5 GENERAL INFORMATION Motors with parameters according to the data sheet comply with the requirements of the IEC 60034-1 standard, and IEC 60034-30 class efficiency IE2 Motor versions:

More information

9.7 Replacement of the compressed air distributor

9.7 Replacement of the compressed air distributor 9.6.6 9.6.7 screw in the bolt and to increase unscrew the bolt. For a complete rotation of the bolt, the variation is of 1mm. After measuring the pointer position and the compensatory adjustment screw

More information

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM. QAD#IM6055.REVA

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM.  QAD#IM6055.REVA LSSN Butterfly Valve Installation Operation Maintenance Licence Number: 5326 www.challengervalves.com.au 1 Index 1. INTRODUCTION 1.1 Design Features 3 1.2 Flange and Pipe Compatibility 4 1.3 Operating

More information

barmesapumps.com IB SERIES & 3500 RPM Installation, Operation & Maintenance Manual End Suction Centrifugal Pumps

barmesapumps.com IB SERIES & 3500 RPM Installation, Operation & Maintenance Manual End Suction Centrifugal Pumps Installation, Operation & Maintenance Manual End Suction Centrifugal Pumps IB SERIES 1-15 HP @ 1750 & 3500 RPM IMPORTANT! - Read all instructions in this manual before operating or servicing a pump. Before

More information

Installation and Service Instructions 1012, 1014, 1015, & 1017 Size Pumps

Installation and Service Instructions 1012, 1014, 1015, & 1017 Size Pumps Installation and Service Instructions 1012, 1014, 1015, & 1017 Size Pumps Excellence at work. Excellence in life. Table of Contents General Description 3 The Pumping Principle 3 Location 3 Proper Installation

More information

PROCESS PUMPS (INDIA) PVT LTD

PROCESS PUMPS (INDIA) PVT LTD MANUAL: - M10 HORIZONTAL BPO METALLIC PUMP WITH EXTERNAL MECHANICAL SEAL (GROUP- III & IV) INSTALLATION, OPERATION AND MAINTENANCE MANUAL PROCESS PUMPS (INDIA) PVT LTD Plot No.86, III Phase, Peenya Industrial

More information

Installation and Service Instructions 1018, 1020, 1022, & 1024 Size Pumps

Installation and Service Instructions 1018, 1020, 1022, & 1024 Size Pumps Installation and Service Instructions 1018, 1020, 1022, & 1024 Size Pumps Excellence at work. Excellence in life. Table of Contents General Description 3 The Pumping Principle 3 Location 3 Proper Installation

More information

SERIES PC INSTRUCTION AND OPERATION MANUAL

SERIES PC INSTRUCTION AND OPERATION MANUAL MEGGA SERIES PC INSTRUCTION AND OPERATION MANUAL Models PCT and PCF Close-coupled and frame-mounted single-stage horizontal end-suction pumps. WARNING: Read this manual before installing or operating this

More information

Troubleshooting:Passenger Car

Troubleshooting:Passenger Car Troubleshooting:Passenger Car Troubleshooting If the engine or other parts has the problem, it is possible to break the exchange turbocharger again. Please confirm the notes below and inspect each part

More information

NSGV EVE-ER I, O, & M MANUAL

NSGV EVE-ER I, O, & M MANUAL TABLE OF CONTENTS Rail Layout.. Page 1 Support Placement...Page 1 Rail Assembly.Page 1 Rail Duct Connections.. Page 2 Rubber Lip Installation.. Page 3 Pneumatic End Stop. Page 4 End Stop. Page 4 End Cap..

More information

Dismantling and assembling transmission

Dismantling and assembling transmission 27-640 Dismantling and assembling transmission Operation number of the operation texts and work units or standard texts and flat rates: 27-4010 P27-5367-61 Control pressure cable (98) Slacken, remove and

More information

Ph: (07) Fax: (07) Pump Manual

Ph: (07) Fax: (07) Pump Manual sales@scintex.com.au www.scintex.com.au Ph: (07) 3137 0135 Fax: (07) 3041 0541 Pump Manual 12V 75LPM Vane Pump & Vane Pump Station SPEP12V75 & SP12VFS75 SPEP12V75 SP12VFS75 Parts List No. Part Name QTY

More information

Installation and Operating Manual

Installation and Operating Manual The EZ Series Slurry Pump Installation and Operating Manual Excellence Pump Industry Co., Ltd. SAFETY INFORMATION The following safety information relating to pump operation and maintenance should be carefully

More information

HYDRAULIC PALLET TRUCK MODEL NO: PT540M/BM/CM & PT685BM/CM PART NO: , , , ,

HYDRAULIC PALLET TRUCK MODEL NO: PT540M/BM/CM & PT685BM/CM PART NO: , , , , HYDRAULIC PALLET TRUCK MODEL NO: PT540M/BM/CM & PT685BM/CM PART NO: 7631700, 7631705, 7631710, 7631715, 7631720 OPERATION & MAINTENANCE INSTRUCTIONS LS0316 INTRODUCTION Thank you for purchasing this CLARKE

More information

Pumps and Maintenance

Pumps and Maintenance Pumps and Maintenance Questions 1) Where would you find information on when to lubricate a pump? 2) What problems can develop if too much grease is used in lubricating an electric motor? 3) Why should

More information

OPERATION, MAINTENANCE AND OVERHAUL INSTRUCTIONS FOR PB18 SERIES PORTABLE PUMPS

OPERATION, MAINTENANCE AND OVERHAUL INSTRUCTIONS FOR PB18 SERIES PORTABLE PUMPS WATEROUS COMPANY Form No. F 2058 South St. Paul, Minnesota 55075 January, 1992 OPERATION, MAINTENANCE AND OVERHAUL INSTRUCTIONS FOR PB18 SERIES PORTABLE PUMPS Printed in U.S.A. Waterous Company F 2058

More information

Installation Operation & Maintenance Manual. Oil-Free (Dry) Rotary Vane Vacuum Pump Systems

Installation Operation & Maintenance Manual. Oil-Free (Dry) Rotary Vane Vacuum Pump Systems Installation Operation & Maintenance Manual Oil-Free (Dry) Rotary Vane Vacuum Pump Systems Part No. 9983-0000-S07 / November 2018 OIL-FREE (DRY) ROTARY VANE VACUUM PUMP SYSTEMS TABLE OF CONTENTS CUSTOMER

More information

Vertical Chemical Pumps

Vertical Chemical Pumps Vertical Chemical Pumps JKD/JKT/JKH/JKP/JKV Series Instruction Manual JIEKAI INDUSTRIAL EQUIPMENT CO., LTD. 0 1. Introduction Table of Contents Model Definition... 2 Specification And Suitable Applications...

More information

Coro-Vane Maintenance CP471. and Disassembly

Coro-Vane Maintenance CP471. and Disassembly Coro-Vane Maintenance CP471 and Disassembly CoroVane Pumps Pumps all have discharge and suction pressure openings. The following slides depict a 1021, but all standard pumps are repaired the same. Grease

More information

PROCESS PUMPS (INDIA) PVT LTD

PROCESS PUMPS (INDIA) PVT LTD VERTICAL CANTILEVER SHAFT SUMP PUMP (PPCS)_ METALLIC INSTALLATION, OPERATION AND MAINTENANCE MANUAL PROCESS PUMPS (INDIA) PVT LTD Plot No.86, III Phase, Peenya Industrial Area, Bangalore 560058 Phone:

More information

NSGV Direct Drive Pressure Blower (AF) Aluminum Housing & Wheel

NSGV Direct Drive Pressure Blower (AF) Aluminum Housing & Wheel NSGV SERIES AF PRESSURE BLOWER I, O & M MANUAL NSGV Direct Drive Pressure Blower (AF) Aluminum Housing & Wheel RECEIVING AND INSPECTION All shipments are F.O.B. factory, Decatur, Illinois. It is, therefore,

More information

our contribution for Sealless Magnetic Coupled Multistage Centrifugal Pumps Type HZM / HZMR / HZMB environmental protection

our contribution for Sealless Magnetic Coupled Multistage Centrifugal Pumps Type HZM / HZMR / HZMB environmental protection Sealless Magnetic Coupled Multistage Centrifugal Pumps Type HZM / HZMR / HZMB our contribution for environmental protection General DICKOW-pumps of series HZM are sealless multistage horizontal centrifugal

More information

Maintenance Information

Maintenance Information 45530136 Edition 1 July 2008 Electric Screwdrivers EL 24V DC Series Maintenance Information Save These Instructions WARNING Always wear eye protection when operating or performing maintenance on this tool.

More information

PIERBURG. Carburetor: 2E3

PIERBURG. Carburetor: 2E3 PIERBURG Carburetor: 2E3 1 fast idle adjusting screw 2 throttle lever 3 fuel mixture adjusting screw 4 main body 5 idle cut off valve 6 stop screw 7 accelerator pump cover 8 diaphragm 9 spring 10 valve

More information

DP556 Pump. 55:1, Air-operated, Grease. General. Operation. Technical Data. Installation. Mounting with Reinforced Cover (Recommended)

DP556 Pump. 55:1, Air-operated, Grease. General. Operation. Technical Data. Installation. Mounting with Reinforced Cover (Recommended) DP556 Pump 55:1, Air-operated, Grease General The DP556 Pump is a compressed air-operated reciprocating piston pump. This high capacity demand pump is compatible with mineral and synthetic grease and suitable

More information

Eurovacuum Installations and Operating manual EVD Series Vacuum pumps Models: EVD-6 to EVD-90. Double Stage Oil Lubricated Rotary Vane Vacuum Pump

Eurovacuum Installations and Operating manual EVD Series Vacuum pumps Models: EVD-6 to EVD-90. Double Stage Oil Lubricated Rotary Vane Vacuum Pump Eurovacuum Installations and Operating manual EVD Series Vacuum pumps Models: EVD-6 to EVD-90 Double Stage Oil Lubricated Rotary Vane Vacuum Pump Eurovacuum EVD-Series Double Stage Oil Sealed Rotary Vane

More information

Ver Trunnion Ball Valve INSTALLATION, OPERATION AND MAINTENANCE MANUAL FBV/IOM/BA02

Ver Trunnion Ball Valve INSTALLATION, OPERATION AND MAINTENANCE MANUAL FBV/IOM/BA02 Ver. 2008 Trunnion Ball Valve INSTALLATION, OPERATION AND MAINTENANCE MANUAL FBV/IOM/BA02 TABLE OF CONTENTS 1 APPLICATIONS...2 1.1 Applications...2 1.2 Performance Specifications...2 2 APPLICABLE STANDARDS...2

More information

Hand Pallet Truck NC. Operation Manual

Hand Pallet Truck NC. Operation Manual Hand Pallet Truck -------NC Operation Manual Operation Manual 1 Application Range This product is suitable for using in rated load of up to 5500lbs. This PL5500HD is the perfect jack for handling palletized

More information

PO Box 645, Stockton, Missouri, FAX superiorgearbox.com W D0446-A 4/1/05 1

PO Box 645, Stockton, Missouri, FAX superiorgearbox.com W D0446-A 4/1/05 1 W000-7000-D0446-A 4/1/05 1 SAFETY PRECAUTIONS CAUTION Please read this entire document prior to operating the gear drive. Gear drive failure and / or injury to operators may be caused by improper installation,

More information

NATIONAL TURBINE CORPORATION INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

NATIONAL TURBINE CORPORATION INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS NATIONAL TURBINE CORPORATION INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS MILLENNIUM SERIES MULTISTAGE CENTRIFUGAL BLOWERS AND EXHAUSTERS NATIONAL TURBINE CORPORATION 374 NORTHERN LIGHTS DRIVE

More information

Hey-Wel. 3-lobe Roots Blower OPERATION MANUAL

Hey-Wel. 3-lobe Roots Blower OPERATION MANUAL Hey-Wel 3-lobe Roots Blower OPERATION MANUAL We would like to thank you at the outset for purchasing the Heywel Roots blower. We have though already done strict inspections on every detail of our blowers

More information

Read and understand this manual for safely usage.

Read and understand this manual for safely usage. TS02-0183 INSTRUCTION MANUAL FOR GUARD TYPE LEVEL SENSOR MODEL:FC Read and understand this manual for safely usage. This manual describes the product of standard specification. Read the other manual for

More information

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c. 24V DC-CW332 DOC531/11 Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c. To obtain the best performance from your Pressurised water

More information

TECHNICAL SERVICE MANUAL GENERAL PURPOSE BRACKET MOUNTED PUMPS SERIES 115 MODELS G, GX2, H and HX4

TECHNICAL SERVICE MANUAL GENERAL PURPOSE BRACKET MOUNTED PUMPS SERIES 115 MODELS G, GX2, H and HX4 TECHNICAL SERVICE MANUAL GENERAL PURPOSE BRACKET MOUNTED PUMPS SERIES 115 MODELS G, GX2, H and HX4 SECTION 2 BULLETIN TSM-115-C ISSUE A CONTENTS Special Information 2 Maintenance 2 Packed Pump Breakdown

More information

Operation and Maintenance Manual

Operation and Maintenance Manual BM / BMA Hydrometers ½ Operation and Maintenance Manual i This manual is intended for use by the users of this equipment. The information contained herein is the property of the Arad Ltd. Dalia and may

More information

DP5 Pump. 5:1, Air-operated, Heavy Duty, Oil. General. Operation. Technical Data. Installation R1 09/10

DP5 Pump. 5:1, Air-operated, Heavy Duty, Oil. General. Operation. Technical Data. Installation R1 09/10 DP5 Pump 5:1, Air-operated, Heavy Duty, Oil General The DP5 Pump is a compressed air-operated reciprocating piston medium pressure pump. These pumps are suitable for distribution of all types of light

More information

Maintenance Information

Maintenance Information 16575128 Edition 2 May 2014 Air Grinder, Sander or Polisher 77A Series Maintenance Information Save These Instructions Product Safety Information Failure to observe the following warnings, and to avoid

More information

APIFLO-M series Series

APIFLO-M series Series APIFLO-M series Series Horizontal Multistage Pump According to API610 Capacity: up to 650m 3 /h (50Hz) up to 780 m 3 /h (60Hz) Head: up to 1200m (50Hz) up to 1728 m (60Hz) Pressure: APIFLO-M: up to 25

More information

To ensure proper installation, digital pictures with contact information to before startup.

To ensure proper installation,  digital pictures with contact information to before startup. Check List for Optimal Filter Performance? There should be no back-pressure on the flush line. A 1 valve should have a 2 waste line, and 2 valve should have a 3 waste line. Do not use rubber hosing or

More information

GRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions

GRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions GRUNDFOS INSTRUCTIONS MTC Installation and operating instructions LIMITED WARRANTY Products manufactured by GRUNDFOS PUMPS CORPORATION (Grundfos) are warranted to the original user only to be free of defects

More information

TECHNICAL SERVICE MANUAL GENERAL PURPOSE JACKETED PUMPS SERIES 230 MODELS HX4, KK, LQ, Q, M, N

TECHNICAL SERVICE MANUAL GENERAL PURPOSE JACKETED PUMPS SERIES 230 MODELS HX4, KK, LQ, Q, M, N CONTENTS TECHNICAL SERVICE MANUAL GENERAL PURPOSE JACKETED PUMPS SERIES 230 MODELS HX4, KK, LQ, Q, M, N SECTION 2 BULLETIN TSM-230-V ISSUE A Special Information 2 Maintenance 2 Packed Pump Breakdown Drawing

More information

Agri KAM INSTALLATION, OPERATION AND MAINTENANCE MANUAL. A View of KBL Dewas Manufacturing Plant. A Kirloskar Group Company KIRLOSKAR BROTHERS LIMITED

Agri KAM INSTALLATION, OPERATION AND MAINTENANCE MANUAL. A View of KBL Dewas Manufacturing Plant. A Kirloskar Group Company KIRLOSKAR BROTHERS LIMITED A View of KBL Dewas Manufacturing Plant KIRLOSKAR Agri KAM MONOBLOC KIRLOSKAR BROTHERS LIMITED A Kirloskar Group Company CORPORATE OFFICE : YAMUNA, Survey No. 98 (-7), Baner, Pune 411 045 (India) Phone

More information

D-Series Blowers and Exhausters

D-Series Blowers and Exhausters Operation and Maintenance Manual D-Series MONOXIVENT - SOURCE CAPTURE SYSTEMS - info@ Oct. - 2015 MONOXVENT BLOWERS AND EXHAUSTERS D05-1 D05-3 D10-1 D10-3 D15-1 D15-3 D20-1 D20-3 D30-1 D30-3 ½ HP TEFC

More information

A Series 50HZ. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001

A Series 50HZ. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001 A - Series A Series ISO-9 AVC/AVI/AVS HZ Evak Pump Technology Corp. No., Zhongshan Rd., Qingshui Township, Taichung County, Taiwan. Tel : +-- Fax: +--9 www.evak-pumps.com Vol. PIAV- A-Series Index Pump

More information

XFLO XS SERIES. Single Stage Double Suction Split Casing Centrifugal Pump

XFLO XS SERIES. Single Stage Double Suction Split Casing Centrifugal Pump XFLO P U M P S XS SERIES Single Stage Double Suction Split Casing Centrifugal Pump General and Construction 1. Applications Waterworks, Irrigation, Drainage pumping stations, Power stations, Industrial

More information

HTM Circulation Pumps acc. to DIN EN 733 Type NKLs

HTM Circulation Pumps acc. to DIN EN 733 Type NKLs HTM Circulation Pumps acc. to DIN EN 733 Type NKLs General The DICKOW standard HTM pumps, series NKLs according to EN 733, are designed as centrifugal pumps of light duty for handling heat transfer media.

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL Publication T3-76, Rev. 1 Dated: May 9, 21 INSTALLATION AND OPERATING MANUAL MODEL: T3-I TURBOTWIN Engine Air Starter AN96-419 From Tech Development Inc 68 Poe Ave. Dayton OH 45414 Tel: (937) 898-96 Fax:

More information

12. FRONT WHEEL/FRONT BRAKE/

12. FRONT WHEEL/FRONT BRAKE/ 12 4.5kgm 0.9kg-m 4.5kg-m 12-0 SERVICE INFORMATION... 12-1 HYDRAULIC BRAKE... 12-10 TROUBLESHOOTING... 12-2 FRONT SHOCK ABSORBER... 12-16 FRONT WHEEL... 12-3 STEERING HANDLEBAR... 12-19 FRONT BRAKE...

More information