Installation and Programming Manual Part: Building Network Interface Card Product: 4100ES

Size: px
Start display at page:

Download "Installation and Programming Manual Part: Building Network Interface Card Product: 4100ES"

Transcription

1 Installation and Programming Manual Part: Building Network Interface Card Product: 4100ES Cautions and Warnings READ AND SAVE THESE INSTRUCTIONS- Follow the instructions in this installation manual. These instructions must be followed to avoid damage to this product and associated equipment. Product operation and reliability depend upon proper installation. DO NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED- Upon unpacking your Simplex product, inspect the contents of the carton for shipping damage. If damage is apparent, immediately file a claim with the carrier and notify an authorized Simplex product supplier. ELECTRICAL HAZARD - Disconnect electrical field power when making any internal adjustments or repairs. All repairs should be performed by a representative or authorized agent of your local Simplex product supplier. STATIC HAZARD - Static electricity can damage components. Handle as follows: Ground yourself before opening or installing components. Prior to installation, keep components wrapped in anti-static material at all times. FCC RULES AND REGULATIONS PART 15 - This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Introduction The Building Network Interface Card (BNIC) allows the connection of a 4100ES Fire Alarm Control Panel (FACP) to a local area Ethernet network (LAN) or to a dedicated Ethernet network used only for the fire alarm systems. Note: The BNIC is for ancillary use only and does not provide any fire alarm or burglary function other than a tool for service technicians to use in configuring and maintaining the system. IMPORTANT: To use the BNIC, you must have a 4100ES Master Controller Card ( ) installed in your system. If you are using an older 4100U CPU Card, upgrade using the upgrade kit. Ethernet Ethernet Authorized Service PC Facility LAN BNIC Figure 1. BNIC Connection Diagram 4100ES Fire Alarm Control Panel In this Publication This publication discusses the following topics: Topic Page Overview 2 Card Specifications and Layout 3 Configuration 4 Mounting the Card 6 Wiring and Cable Requirements 7 Programming the BNIC 8 Accessing the FACP through the BNIC 12 Building Network Interface Card MIS/IT Configuration Worksheet SimplexGrinnell LP. All rights reserved. Specifications and other information shown were current as of publication and are subject to change without notice. Simplex and the Simplex logo are trademarks of Tyco International Ltd. and its affiliates and are used under license Rev. A

2 Overview BNIC Overview The BNIC isolates the FACP from the external or building network but allows an authorized user with the proper security clearance to access the FACP through the Network. Authorization is provided transparently through service tools such as the ES Programmer. A service tool connected to the FACP through the BNIC will behave as if it were directly connected to the Panel. Package Contents This package includes: One BNIC Hardware to secure the BNIC in the Expansion Bay Two 5ft (1.5 m) Ethernet cables ( ) FACP Requirements The FACP must meet the following requirements for the card to function properly: It must use the 4100ES Master Controller Card It must use ES FACP System Firmware version 1.01 or later 2

3 Card Specifications and Layout Card Specifications Table 1. Card Specifications Card Size: 4 x 11¼ inches (102 x 286 mm) /Dual Block Module Earth Fault Detection (Port A only): 10 K Ohm Max direct current connection to earth Operating Conditions: Operating Temperature Range 32 o F o F (0 o C-49 o C ) Operating Humidity Range Up to 93% relative humidity at 90 o F (32 o C ) Power Requirements: Operating Voltage Maximum Current over Operating Range Nominal 24 VDC from PDI 291 ma (maximum over range) BNIC Ethernet Port Label EXTERNAL NETWORK PANEL CONNECTION Connections to External Networks Connection to NXP CPU Card Connection to Panel Download Port EARTH DETECT BUILDING CPU DISPLAY Port A Port B Port C Port D (Placed over the RJ-45 jacks) Port status LEDs Status LEDs eslave Address Switch, SW1 Communication Loss LED Earth Fault LED Reset LED Auto Forward Jumper MAC Address Label Future Expansion Port PDI Connector (bottom side) Serial Number MAC address Chip Socket Figure 2. BNIC Layout 3

4 Configuration Setting DIP Switch SW1 Dual Inline Package (DIP) Switch SW1 is used to set the BNIC eslave address as identified in the ES Panel Programmer job. The address is set with the card in its normal orientation (connectors up) as shown in the mounting instructions (see Figure 5). Table 2. BNIC DIP Switch functions Switch Position Function Figure SW1-1 SW1-2 through SW1-8 ON OFF ON OFF Sets the card to online and allows the card to operate normally. Sets the card offline which stops all communication to the FACP. Set the BNIC eslave address. Refer to Table 3 for a complete list of switch settings for all possible card addresses. Table 3. BNIC DIP Switch Addresses DIP Switches SW1-2 through SW1-8 set the Card Address Position 1 of SW1 is the online / offline setting of the card and must be set to ON Figure 3. BNIC DIP Switch Address SW 1-2 SW 1-3 SW 1-4 SW 1-5 SW 1-6 SW 1-7 SW 1-8 Address SW 1-2 SW 1-3 SW 1-4 SW 1-5 SW 1-6 SW 1-7 SW ON ON ON ON ON ON OFF 61 ON OFF OFF OFF OFF ON OFF 2 ON ON ON ON ON OFF ON 62 ON OFF OFF OFF OFF OFF ON 3 ON ON ON ON ON OFF OFF 63 ON OFF OFF OFF OFF OFF OFF 4 ON ON ON ON OFF ON ON 64 OFF ON ON ON ON ON ON 5 ON ON ON ON OFF ON OFF 65 OFF ON ON ON ON ON OFF 6 ON ON ON ON OFF OFF ON 66 OFF ON ON ON ON OFF ON 7 ON ON ON ON OFF OFF OFF 67 OFF ON ON ON ON OFF OFF 8 ON ON ON OFF ON ON ON 68 OFF ON ON ON OFF ON ON 9 ON ON ON OFF ON ON OFF 69 OFF ON ON ON OFF ON OFF 10 ON ON ON OFF ON OFF ON 70 OFF ON ON ON OFF OFF ON 11 ON ON ON OFF ON OFF OFF 71 OFF ON ON ON OFF OFF OFF 12 ON ON ON OFF OFF ON ON 72 OFF ON ON OFF ON ON ON 13 ON ON ON OFF OFF ON OFF 73 OFF ON ON OFF ON ON OFF 14 ON ON ON OFF OFF OFF ON 74 OFF ON ON OFF ON OFF ON 15 ON ON ON OFF OFF OFF OFF 75 OFF ON ON OFF ON OFF OFF 16 ON ON OFF ON ON ON ON 76 OFF ON ON OFF OFF ON ON 17 ON ON OFF ON ON ON OFF 77 OFF ON ON OFF OFF ON OFF 18 ON ON OFF ON ON OFF ON 78 OFF ON ON OFF OFF OFF ON 19 ON ON OFF ON ON OFF OFF 79 OFF ON ON OFF OFF OFF OFF 20 ON ON OFF ON OFF ON ON 80 OFF ON OFF ON ON ON ON 21 ON ON OFF ON OFF ON OFF 81 OFF ON OFF ON ON ON OFF 22 ON ON OFF ON OFF OFF ON 82 OFF ON OFF ON ON OFF ON 23 ON ON OFF ON OFF OFF OFF 83 OFF ON OFF ON ON OFF OFF 24 ON ON OFF OFF ON ON ON 84 OFF ON OFF ON OFF ON ON 25 ON ON OFF OFF ON ON OFF 85 OFF ON OFF ON OFF ON OFF 26 ON ON OFF OFF ON OFF ON 86 OFF ON OFF ON OFF OFF ON 27 ON ON OFF OFF ON OFF OFF 87 OFF ON OFF ON OFF OFF OFF 28 ON ON OFF OFF OFF ON ON 88 OFF ON OFF OFF ON ON ON 29 ON ON OFF OFF OFF ON OFF 89 OFF ON OFF OFF ON ON OFF 30 ON ON OFF OFF OFF OFF ON 90 OFF ON OFF OFF ON OFF ON 31 ON ON OFF OFF OFF OFF OFF 91 OFF ON OFF OFF ON OFF OFF 32 ON OFF ON ON ON ON ON 92 OFF ON OFF OFF OFF ON ON 33 ON OFF ON ON ON ON OFF 93 OFF ON OFF OFF OFF ON OFF 34 ON OFF ON ON ON OFF ON 94 OFF ON OFF OFF OFF OFF ON 35 ON OFF ON ON ON OFF OFF 95 OFF ON OFF OFF OFF OFF OFF 36 ON OFF ON ON OFF ON ON 96 OFF OFF ON ON ON ON ON 37 ON OFF ON ON OFF ON OFF 97 OFF OFF ON ON ON ON OFF 38 ON OFF ON ON OFF OFF ON 98 OFF OFF ON ON ON OFF ON 39 ON OFF ON ON OFF OFF OFF 99 OFF OFF ON ON ON OFF OFF 40 ON OFF ON OFF ON ON ON 100 OFF OFF ON ON OFF ON ON 41 ON OFF ON OFF ON ON OFF 101 OFF OFF ON ON OFF ON OFF 42 ON OFF ON OFF ON OFF ON 102 OFF OFF ON ON OFF OFF ON 43 ON OFF ON OFF ON OFF OFF 103 OFF OFF ON ON OFF OFF OFF 44 ON OFF ON OFF OFF ON ON 104 OFF OFF ON OFF ON ON ON 45 ON OFF ON OFF OFF ON OFF 105 OFF OFF ON OFF ON ON OFF 46 ON OFF ON OFF OFF OFF ON 106 OFF OFF ON OFF ON OFF ON 47 ON OFF ON OFF OFF OFF OFF 107 OFF OFF ON OFF ON OFF OFF 48 ON OFF OFF ON ON ON ON 108 OFF OFF ON OFF OFF ON ON 49 ON OFF OFF ON ON ON OFF 109 OFF OFF ON OFF OFF ON OFF 50 ON OFF OFF ON ON OFF ON 110 OFF OFF ON OFF OFF OFF ON 51 ON OFF OFF ON ON OFF OFF 111 OFF OFF ON OFF OFF OFF OFF 52 ON OFF OFF ON OFF ON ON 112 OFF OFF OFF ON ON ON ON 53 ON OFF OFF ON OFF ON OFF 113 OFF OFF OFF ON ON ON OFF 54 ON OFF OFF ON OFF OFF ON 114 OFF OFF OFF ON ON OFF ON 55 ON OFF OFF ON OFF OFF OFF 115 OFF OFF OFF ON ON OFF OFF 56 ON OFF OFF OFF ON ON ON 116 OFF OFF OFF ON OFF ON ON 57 ON OFF OFF OFF ON ON OFF 117 OFF OFF OFF ON OFF ON OFF 58 ON OFF OFF OFF ON OFF ON 118 OFF OFF OFF ON OFF OFF ON 59 ON OFF OFF OFF ON OFF OFF 119 OFF OFF OFF ON OFF OFF OFF 60 ON OFF OFF OFF OFF ON ON 4

5 Configuration (continued) Jumpers Jumper P1 sets the Autoforward mode to determine how data traffic is handled before the BNIC CPU is online. Setting 1-2: This is the recommended default setting. In this mode the BNIC does not allow traffic to be routed through the switch until the BNIC CPU is online and running. LED Indicators Table 4 lists the different LED indicators found on the BNIC that are troubleshooting aids. Table 4. BNIC LED Descriptions LED Description Signification Port A (LED 9) Port B (LED 6) OFF = No Connection Port Status LED ON Steady = Non-active connection Port C (LED 2) ON Blinking = Active connection Port D (LED 1) X (LED 5) Used for manufacturing and development only, not Y (LED 4) Card Status LED used for installed BNIC Z (LED 3) Offline (LED 7) ON = Offline (not communicating with 4100ES Offline Indication Master Controller Card) OFF = Normal Operation Reset (LED 10) (see Figure 2 for positioning) Earth Fault (LED 8) Reset Indication Earth Fault Indication on Port A ON = BNIC is in reset Off = Normal Operation ON = Earth Fault detected on Port A OFF = No Earth Fault detected Port A Port B Port C Port D Port A LED9 LED7 LED8 Earth Fault Port A Port B LED6 LED5 LED4 Port C LED2 LED3 Port D LED1 Figure 4. LED positioning 5

6 Mounting the Card Mounting the BNIC The BNIC must be mounted in the master controller cabinet and can be placed in any open expansion bay slot. Use the following steps as well as Figure 5 to properly install the BNIC: Note: The card must be installed with the ports facing up. 1. Insert the Power Distribution Interface (PDI) connector on the back of the card into one of the bottom PDI connectors on the expansion bay. 2. Secure the card in place using the provided hardware. EXPANSION BAY BNIC (Install with the ports at the top) SCREW HOLES WASHERS STANDOFFS SCREW RETAINERS SCREWS Figure 5. Mounting the BNIC into the Expansion Bay 6

7 Wiring and Cable Requirements Wiring All Ethernet ports on the BNIC are auto-crossover (crossover cables are not required) and compatible with 802.3u, 100Base-TX type standard RJ45 type connections. WARNING: Miswiring the BNIC can result in limited Network Connectivity for users attempting to log into the Network. Cable requirements: Category 5 (CAT5) cable or greater is required for 100Mbit operation. Using lower grade (i.e. Category 3) cables can result in slower link speeds or shorter distances which may affect the performance of your connection. The maximum distance from the BNIC to the next Ethernet termination (router, switch etc.) is 328 ft (100 m) with CAT5 cable. Cables are to be in conformance with TIA/EIA-568-B standard. Not supported: Style 7 connection. Only one path through the building network should exist. Note: Multiple connections to separate networks are permissible (i.e., dedicated network and building network). Power over Ethernet (PoE). External Connections: 1. Port A provides Earth Detection for optional External Network connection needs, see Important Notes in the Figure 6 BNIC Wiring Diagram. 2. Port B connects to the Building Network. Panel Connections: 3. Port C connects to the CPU (Master Controller Card) Ethernet connection. Note: This connection is required to enable communication between the BNIC and the CPU. 4. Port D connects to the Display assembly at the Ethernet connection board ( ). Important: Port A is a special application connection that provides Earth Detection by placing a low DC voltage signal on the port. It is NOT COMPATIBLE with PoE (Power over Ethernet) connections and should NEVER be connected to a PoE port! NXP Master Card Controller ( ) CPU Ethernet Port BAT ON BAT OFF SERVICE PORT DISPLAY Top View of the Ethernet Connection ( ) This connects the BNIC to the Display Assembly Building Network Optional Port (Port A) Important: Before disconnecting Ethernet cables from BNIC, identify and label the function of each cable to ensure connection to the correct Port. Port A Port B Port C Port D BNIC Figure 6. BNIC Wiring Diagram Connection to Display Assembly (Port D) Connection to NXP CPU Card (Port C) Connection to the Building Network (Port B) 7

8 Programming the BNIC Software Requirements In order to properly program the BNIC the computer must use FACP System Firmware version 1.01 or later. Consult the ES Panel Programmer s Manual ( ) for more information. Adding the BNIC to the Programmer Follow these steps to add the BNIC to the programmer: 1. Start the programmer software. 2. Open an existing job or create a new one. If you create a new job you must change the box size to a 2 or 3 bay box. 3. Select the Hardware tab. 4. Click the Box icon. 5. Right-click the appropriate Bay and select Add a Card. See Figure 7. Figure 7. Adding a card 6. Select INTERFACE from the Category drop-down menu. 7. Select Building Interface Network Card from the Type drop-down menu. 8. Click OK. Figure 8. Select the BNIC 8

9 Programming the BNIC (continued) Adding the BNIC The BNIC appears in the Tree View. Figure 9. Adding the BNIC Configuring the BNIC Follow these steps to configure the BNIC: 1. Right click on the BNIC icon in the Hardware Tree View. Figure 10. Accessing the card properties 2. Select and open the Properties option. This will open the BNIC window. 3. Configure the Card Properties tab by setting: The Card Address The Card Custom Label The Card Alternate Custom Label The Unit The Box The Bay The Location Note: For additional information on card properties consult the ES Programmer Manual. Figure 11. Card Properties tab Continued on next page 9

10 Programming the BNIC (continued) Configuring the BNIC 4. Select the BNIC IP Settings tab. 5. Configure the BNIC IP Settings tab by setting: The IP Address. - Use the Dynamic Host Configuration Protocol (DHCP) option to have the Building Network automatically assign an IP address to the card. - Select the Use the following address option if you want to set the IP address manually and enter a Static IP address. - For Static IP Addresses: If you are using a Customer LAN, refer to the worksheet information on Page 12 for customer provided addresses If you are using a Proprietary Fire Alarm LAN, the Recommended Convention for the Subnet is Important: To avoid network conflicts, do not use for an IP Address when assigning BNICs. The mdns works within the same broadcast domain. Typically all devices on a single subnet are on the same broadcast domain and are reachable via IP broadcast. The facility MIS/IT department will provide guidance on use of mdns. The Domain Name Server (DNS). - By default, the Obtain DNS server address automatically option is selected. It is recommended to leave this setting selected. - A domain server name can be entered manually in the Use the following DNS server address box. Figure 12. BNIC IP Settings tab 10

11 Programming the BNIC (continued) Configuring the BNIC Multicast Domain Name Server (mdns). - The mdns works within the same broadcast domain. Typically all devices on a single subnet are on the same broadcast domain and are reachable via IP broadcast. The facility MIS/IT department will provide guidance on use of mdns. - A device that supports mdns advertises its name and available services using IP broadcasts (multicast address ). An mdns client (the Programmer) can make a request for a device with a particular service to advertise itself. This enables the user to locate devices. If you do not enable this feature the BNIC will not Advertise itself mdns Modes: NORMAL (default): The BNIC will periodically advertise its name and service for 2 minutes after startup (unsolicited advertisement). QUIET: the BNIC will advertise its name and service once at startup. QUIET mode may be used at the request of an IT department that does not want unsolicited traffic on the network. 6. Select the BNIC Network Ports tab. Ensure that the settings are the same as those featured in Figure 13. Figure 13. BNIC Network tab 7. Click on the OK button at the bottom of the BNIC window to save the BNIC settings. 11

12 Accessing the FACP through the BNIC Terminal Emulation To access the FACP from the Building Network once the BNIC has been installed: 1. Connect the PC to a Building Network Ethernet port. 2. Start the ES Panel Programmer. 3. Click on Terminal on the Programmer s task bar. 4. Click on Network. 5. Click on Remote Panel. This will automatically launch Tera Term. Tera Term will connect using the IP information from the current job. Figure 14. Opening Tera Term 6. Proceed as you would if you were connected to the FACP through the service port. 12

13 Building Network Interface Card MIS/IT Configuration Worksheet Terms DHCP Dynamic Host Control Protocol DNS Domain Name System mdns Multicast Domain Name System MAC Media Access Control FACP Fire Alarm Control Panel RFC Request for Comments About the BNIC BNIC Installation Prerequisite The Building Network Interface Card (BNIC) is a module that mounts internally to a fire alarm control panel (FACP) located on your premises to provide the ability to access the FACP through a secure IP network channel. To interface the FACP to your Internet LAN, an EIA/TIA-568A CAT-5 (10/100-BaseT)-compliant Ethernet drop to the panel is required. This connection requires a standard Ethernet RJ-45 terminating connector. There are 2 options available for obtaining an IP address for the BNIC. Before installing the BNIC, coordinate with the MIS/IT department to determine how they want the system to operate. Customer Network: Option 1: DHCP served IP address. This is the preferred method for obtaining an IP address. In order for the BNIC to function properly, DHCP must be used in conjunction with a name service (DNS or mdns). Option 2: Fixed IP address. This method should only be used when a name service is not available. There are 2 name service options available for resolving the FACP name to an IP address. Option 1: DNS. DNS is required when the network hosts (FACPs and the service PC) will not be in the same broadcast domain. This is normally the case when the network hosts are on different subnets. Option 2: mdns. mdns is the preferred method when all network hosts (FACP and service PC) are in the same broadcast domain. The name to IP address resolution requires no additional MIS/IT support. mdns also provides FACP panel discovery. Panel Discovery is supported through DNS. This requires additional MIS/IT support. The DNS server must be configured with service records (defined in RFC 2782). This also must be coordinated with the MIS/IT department prior to installation. 13

14 Building Network Interface Card MIS/IT Configuration Worksheet (continued) Before You Approach Your MIS/IT Department For DNS or Fixed IP configuration: Find the MAC address that is printed on a label located near the center of the board. Carefully record this number below because your MIS/IT department will need this information to configure the BNIC properly on your network. The format of the MAC address will look something similar to 00:08:BD:1C:48:1A. Record the BNIC MAC address: : : : : : Ex:00:08:BD:IC:48:1A For DNS: The BNIC will not operate properly if the DNS name does not match the Building Network Panel Name as found under the CPU Ethernet tab in the job configuration. Record the suggested name for the BNIC host. This must be retrieved from the BNIC card editor of the ES Programmer (BNIC IP Settings tab). If the suggested name cannot be used, the Building Network Panel Name must be changed in the job configuration for proper operation. Record the suggested DNS name: Ex: Main_Lobby Minimum Parameters Required to connect the BNIC The IT/MIS Department must complete this section Now you may take this worksheet to your MIS/IT department for assistance in obtaining the parameters required for the BNIC to operate properly on your local network. WARNING: Do not attempt to connect the BNIC using random entries; serious consequences may result. You can inadvertently affect other computers and networked devices on your network. Fixed IP: MIS/IT Assigned BNIC Static IP Address:... Ex: MIS/IT Assigned BNIC Gateway:... Ex: MIS/IT Assigned BNIC Subnet Mask:... Ex: DHCP/DNS: If the assigned name does not match the suggested name: MIS/IT Assigned BNIC DNS Name: Ex:Fire_Panel_1 Check here if DNS Service Records are Enabled (required for panel discovery) The MIS/IT assigned parameters must be added to the job configuration for the FACP, using the BNIC card editor of the ES Programmer. Once the configuration is updated and downloaded to the panel, the BNIC can be connected to the building network. 14

15

16 Rev. A

Expansion Signal (XSIG) Card Installation Instructions

Expansion Signal (XSIG) Card Installation Instructions Expansion Signal (XSIG) Card Installation Instructions Introduction This publication describes the installation procedure for the Expansion Signal (XSIG) Card (4100-5116). This product is compatible with

More information

Audio Operator Interface Installation Instructions

Audio Operator Interface Installation Instructions Audio Operator Interface Installation Instructions Introduction This publication describes the installation procedure for the following: 4100-1243 Microphone 4100-1244 Remote Microphone 4100-1252 Audio

More information

Flex Amplifiers Installation Instructions

Flex Amplifiers Installation Instructions Flex Amplifiers Installation Instructions Introduction This publication describes the installation procedure for the 4100U and 4100ES Flex Amplifiers. This product is compatible with both 4100U and 4100ES

More information

LED/Switch Modules Installation Instructions

LED/Switch Modules Installation Instructions LED/Switch Modules Installation Instructions Introduction This publication describes the installation procedure for the 4100-1288 LED/Switch Controller Card and the associated 4100-1275 to 1278, 4100-1280

More information

Digital/Analog Amplifiers Installation Instructions

Digital/Analog Amplifiers Installation Instructions Digital/Analog Amplifiers Installation Instructions Introduction This publication describes the installation procedure for the 4100U and 4100ES Fire Alarm Control Panels (FACP) family of digital and analog

More information

MAPNET II Transceiver Installation Instructions

MAPNET II Transceiver Installation Instructions MAPNET II Transceiver Installation Instructions Introduction This publication describes the installation procedure for the following versions of the MAPNET II Transceiver card. 4120/4100-0110 MAPNET II

More information

SNMP dedicated to ORVALDI Solar Infini

SNMP dedicated to ORVALDI Solar Infini SNMP dedicated to ORVALDI Solar Infini User s Manual Management Software for Solar Inverter Table of Contents 1. 2. 3. Overview...1 1.1 Introduction...1 1.2 Features...1 1.3 Overlook...1 1.4 Installation

More information

ZT-USB Series User Manual

ZT-USB Series User Manual ZT-USB Series User Manual Warranty Warning Copyright All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year, beginning from the date of delivery

More information

ET9500 BEMS Interface Box Configuration Guide

ET9500 BEMS Interface Box Configuration Guide ET9500 BEMS Interface Box Configuration Guide APPLICABILITY & EFFECTIVITY Explains how to install and configure ET9500 BEMS Interface Box. The instructions are effective for the above as of August, 2015

More information

Quick Setup Guide. WARNING! Connect this product to an AC power source whose voltage is within the range specified on the product's nameplate.

Quick Setup Guide. WARNING! Connect this product to an AC power source whose voltage is within the range specified on the product's nameplate. Thank you for purchasing the Raritan PX intelligent power distribution unit (PDU). The intended use of the Raritan PX is distribution of power to information technology equipment such as computers and

More information

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount Important Safety Messages Read the instructions carefully to become familiar with the equipment before attempting to install, operate,

More information

MCS-BMS-GATEWAY STARTUP GUIDE Covers Model No. FPC-C35

MCS-BMS-GATEWAY STARTUP GUIDE Covers Model No. FPC-C35 Version 4.2 - Rev. 2017-11-30 5580 Enterprise Pkwy. Fort Myers, FL 33905 MCS-BMS-GATEWAY STARTUP GUIDE Covers Model No. FPC-C35 Office: 239-694-0089 Fax: 239-694-0031 www.mcscontrols.com MCS Total Solution

More information

Redbird Insight User Guide

Redbird Insight User Guide Redbird Insight User Guide 1 Copyright 2012 Redbird Flight Simulations Contents Welcome... 3 System Requirements... 4 QUICK START GUIDE...5 Video Display... 6 Support Ethernet Port... 7 Insight DVR Application

More information

Dominion PX. Quick Setup Guide. Before You Begin. Mounting Zero U Models Using L-Bracket. Zero U Size. 1U and 2U Size

Dominion PX. Quick Setup Guide. Before You Begin. Mounting Zero U Models Using L-Bracket. Zero U Size. 1U and 2U Size Dominion PX Quick Setup Guide Thank you for purchasing the Dominion PX intelligent power distribution unit (PDU). The intended use of the Raritan Dominion PX is distribution of power to information technology

More information

Monnit Wireless Range Extender Product Use Guide

Monnit Wireless Range Extender Product Use Guide Monnit Wireless Range Extender Product Use Guide Information to Users This equipment has been tested and found to comply with the limits for a Class B digital devices, pursuant to Part 15 of the FCC Rules.

More information

IBM CMM Quick Reference Guide

IBM CMM Quick Reference Guide IBM CMM Quick Reference Guide Contents Introduction Prerequisites Requirements Components Used CMM Overview CMM Layout Useful CMM Screens Login Screen System Information Screen Event Log Screen Chassis

More information

MIMOJunior MMJ543 WIRELESS 300Mbps OUTDOOR Access Point Built in 13dBi 5GHz DUAL POLARIZATION ANTENNA or 8dBi 2.4GHz DUAL POLARIZATION ANTENNA

MIMOJunior MMJ543 WIRELESS 300Mbps OUTDOOR Access Point Built in 13dBi 5GHz DUAL POLARIZATION ANTENNA or 8dBi 2.4GHz DUAL POLARIZATION ANTENNA product datasheet Package Solution MIMOJunior MMJ543 WIRELESS 300Mbps OUTDOOR Access Point Built in 13dBi 5GHz DUAL POLARIZATION ANTENNA or 8dBi 2.4GHz DUAL POLARIZATION ANTENNA Features MIPS 24K-family

More information

Industrial Renewable Energy. 4-Port 10/100/1000T 802.3at PoE+ Managed Ethernet Switch BSP-360. Quick Installation Guide

Industrial Renewable Energy. 4-Port 10/100/1000T 802.3at PoE+ Managed Ethernet Switch BSP-360. Quick Installation Guide Industrial Renewable Energy 4-Port 10/100/1000T 802.3at PoE+ Managed Ethernet Switch BSP-360 Quick Installation Guide Safety Precautions Please read the following before using: 1. All electrical work must

More information

LCD Annunciator Installation Instructions

LCD Annunciator Installation Instructions 4603-9101 LCD Annunciator Installation Instructions Cautions and Warnings DO NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED. Upon unpacking your Simplex product, inspect the contents of the carton

More information

QUICK START GUIDE FOR ACCESS CONTROL BOARDS. DX Series Four Door TCP/IP Web Server Controller. Model: ACP-DXEL4

QUICK START GUIDE FOR ACCESS CONTROL BOARDS. DX Series Four Door TCP/IP Web Server Controller. Model: ACP-DXEL4 QUICK START GUIDE FOR ACCESS CONTROL BOARDS DX Series Four Door TCP/IP Web Server Controller Model: ACP-DXEL Table of Contents 0- Introduction 0 - Overview 0. - Package Contents 0. - Installation Requirements

More information

INSTALLATION USER MANUAL

INSTALLATION USER MANUAL INSTALLATION & USER MANUAL DYNAMIC LOAD MANAGEMENT -PREMIUM- This document is copyrighted, 2016 by Circontrol, S.A. All rights are reserved. Circontrol, S.A. reserves the right to make improvements to

More information

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16 User Manual CLA-VAL Europe www.cla-val.ch cla-val@cla-val.ch 1 - LIN072UE - 04/16 Table of Contents 1 Introduction... 3 1.1 Precautions Before Starting... 3 1.2 Troubleshooting... 3 1.3 General Disclaimer...

More information

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Dycon D1532SM EN50131/PD6662 Grade 3, 12V 2A Power Supply Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Tel: +44 (0)1443 471 900 Unit A Cwm Cynon Business Park Mountain

More information

INTECH Micro 2300-RTD6

INTECH Micro 2300-RTD6 INTECH Micro 2300-RTD6 6 Channel RTD Input Station Overview. The Intech Micro 2300 Series is a system of modular I/O Remote Stations, that add an even lower cost option to Intech s already extensive intelligent

More information

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1 INSTALLATION GUIDE InBio Pro Series Access Control Panels Date: Dec., 2015 Version: 1.1 2 3 What s in the Box CONTENT 2 Screws & Anchors 2 Screwdriver 4 Diode Contents What s in the Box...2 Optional accessories...4

More information

Note: If anything is damaged or missing, contact your customer representative immediately.

Note: If anything is damaged or missing, contact your customer representative immediately. Package Contents The package includes: 1 Chassis 1-18 leafs according to the amount ordered 18 - X leaf blanks X = the amount ordered 1 leaf fan module 1 spine fan module 9 spines 1-2 management modules

More information

Extended Battery Cabinet for Nfinity

Extended Battery Cabinet for Nfinity POWER PROTECTION Extended Battery Cabinet for Nfinity USER MANUAL TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS................................... 1 ELECTROMAGNETIC COMPATIBILITY.......................................

More information

Pulsar Evolution 2200/3000/3000 XL

Pulsar Evolution 2200/3000/3000 XL www.mgeups.com Pulsar Evolution 2200/3000/3000 XL Installation and user manual MGE UPS Systems 1660 Scenic Avenue Costa Mesa, CA 92626 (714) 557-1636 For service call 1-800-438-7373 www.mgeups.com IMPORTANT

More information

Issue 2.0 December EPAS Midi User Manual EPAS35

Issue 2.0 December EPAS Midi User Manual EPAS35 Issue 2.0 December 2017 EPAS Midi EPAS35 CONTENTS 1 Introduction 4 1.1 What is EPAS Desktop Pro? 4 1.2 About This Manual 4 1.3 Typographical Conventions 5 1.4 Getting Technical Support 5 2 Getting Started

More information

A-200 Speed Dome. Quick Start Guide UD.6L0201D0127A02

A-200 Speed Dome. Quick Start Guide UD.6L0201D0127A02 A-200 Speed Dome Quick Start Guide UD.6L0201D0127A02 Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the company you purchased the unit

More information

ENERGY MANAGER. Installation Manual

ENERGY MANAGER. Installation Manual ENERGY MANAGER Installation Manual Safety Information Manual for Maxem Home Energy Manager. Publication Date: November 1, 2016 Questions or improvements If you see any errors or defects, if you have ideas

More information

SBC450 SBC850 IMPORTANT SAFETY INSTRUCTIONS. 4- and 8-Bay Networked Charging. Stations. Download PDF. English. Table of Contents

SBC450 SBC850 IMPORTANT SAFETY INSTRUCTIONS. 4- and 8-Bay Networked Charging. Stations. Download PDF. English. Table of Contents Publications User Guides SBC450-850 (English) Download PDF English Table of Contents IMPORTANT SAFETY INSTRUCTIONS SBC450 and SBC850 Networked Charging Stations Included Components Charger Controls and

More information

POWERWARE User s Guide VA.

POWERWARE User s Guide VA. POWERWARE 3110 300 700 VA User s Guide www.powerware.com FCC Part 15 Class B EMC Statements NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant

More information

BroadBand PowerShield. 20 AHr Battery. User Manual

BroadBand PowerShield. 20 AHr Battery. User Manual BroadBand PowerShield 20 AHr Battery User Manual 990-1316A 10/2004 Chapter 1 General Information The PowerShield provides a power source for broadband telephony applications. Important Safety Instructions

More information

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount Important Safety Messages Read the instructions carefully to become familiar with the equipment before

More information

Integration of PowerChute Business Edition with EcoStruxure IT

Integration of PowerChute Business Edition with EcoStruxure IT Integration of PowerChute Business Edition with EcoStruxure IT 990-91197-001 07/2018 Introduction PowerChute TM Business Edition Agents can integrate with EcoStruxure TM IT so that PowerChute Agents and

More information

Owners Manual for TPMS plus GPS

Owners Manual for TPMS plus GPS To ensure correct operation and service please read these instructions before installing and operating the TPMS feature of the TPMS/GPS unit. Owners Manual for TPMS plus GPS TABLE OF CONTENTS TIRE PRESSURE

More information

Begin to Use The New ESC: Before use the new ESC please carefully check every connections are correct or not. Yellow motor wire B Blue motor wire A

Begin to Use The New ESC: Before use the new ESC please carefully check every connections are correct or not. Yellow motor wire B Blue motor wire A HIMOTO ZTW Brushless Electronic Speed Control for car or truck Thank you for purchasing ZTW Brushless Electronic Speed Controller(ESC). The ZTW electronic speed control (ESC) is specifically designed for

More information

Eaton Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide

Eaton Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide Eaton 9170 + Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide Class A EMC Statements FCC Part 15 NOTE This equipment has been tested and found to comply with the limits for a Class A digital

More information

IOA Expansion Cabinet. Dual Line Cords Upgrade Instructions

IOA Expansion Cabinet. Dual Line Cords Upgrade Instructions IOA Expansion Cabinet Dual Line Cords Upgrade Instructions Notice The information contained in this document is subject to change without notice. STRATUS COMPUTER INC. MAKES NO WARRANTY OF ANY KIND WITH

More information

CRAGG RAILCHARGER Instruction Manual for 20SMC-12V 20SMC-24V 40SMC-12V 40SMC-24V 60SMC-12V 80SMC-12V

CRAGG RAILCHARGER Instruction Manual for 20SMC-12V 20SMC-24V 40SMC-12V 40SMC-24V 60SMC-12V 80SMC-12V CRAGG RAILCHARGER for 20SMC-12V 20SMC-24V 40SMC-12V 40SMC-24V 60SMC-12V 80SMC-12V Contents 1 Warnings, Cautions, and Notes... 1 2 Description... 2 3 Features... 2 3.1 STANDARD FEATURES... 2 3.2 OPTIONAL

More information

Dynojet Research, Inc. All Rights Reserved. Optical RPM Sensor Installation Guide.

Dynojet Research, Inc. All Rights Reserved. Optical RPM Sensor Installation Guide. 1993-2001 Dynojet Research, Inc. All Rights Reserved.. This manual is copyrighted by Dynojet Research, Inc., hereafter referred to as Dynojet, and all rights are reserved. This manual, as well as the software

More information

PowerChute TM Network Shutdown v3.1. User Guide. VMware

PowerChute TM Network Shutdown v3.1. User Guide. VMware PowerChute TM Network Shutdown v3.1 User Guide VMware 990-4595A-001 Publication Date: December, 2013 Table of Contents Introduction... 1 UPS Configuration... 2 Network Configuration... 3 UPS Configuration

More information

SBC450 and SBC850 Networked Charging Stations SBC450 and SBC850 networked charging stations provide simple charging, SBC450 SBC850.

SBC450 and SBC850 Networked Charging Stations SBC450 and SBC850 networked charging stations provide simple charging, SBC450 SBC850. SBC450 SBC850 4- and 8-Bay Networked Charging Stations IMPORTANT SAFETY INSTRUCTIONS 1. READ these instructions. 2. KEEP these instructions. 3. HEED all warnings. 4. FOLLOW all instructions. 5. DO NOT

More information

BMS RS-485 Card/Box Quick Guide Applicable for hybrid inverter 3KW-10KW

BMS RS-485 Card/Box Quick Guide Applicable for hybrid inverter 3KW-10KW Thank you for purchasing RS485 card/box. This manual contains instructions and warnings that should be followed during the installation, operating and storage of the card. Please keep this manual for further

More information

MetaXpress PowerCore System Installation and User Guide

MetaXpress PowerCore System Installation and User Guide MetaXpress PowerCore System Installation and User Guide Version 1 Part Number: 0112-0183 A December 2008 This document is provided to customers who have purchased MDS Analytical Technologies (US) Inc.

More information

User Manual Industrial Power Storage System (ips) ips-m Series Battery System

User Manual Industrial Power Storage System (ips) ips-m Series Battery System User Manual Industrial Power Storage System (ips) ips-m Series Battery System Copyright The documentation and the software included with this product are copyrighted 2011 by Advantech Co., Ltd. All rights

More information

Cisco Beacon Point Module

Cisco Beacon Point Module Overview of, page 1 Installing a Cisco Beacon Point, page 4 Overview of About (AIR-RM-VBLE2-K9=) is a Bluetooth Low Energy beacon module that is mounted on supported access points. The APs now has the

More information

EPAS Desktop Pro Software User Manual

EPAS Desktop Pro Software User Manual Software User Manual Issue 1.10 Contents 1 Introduction 4 1.1 What is EPAS Desktop Pro? 4 1.2 About This Manual 4 1.3 Typographical Conventions 5 1.4 Getting Technical Support 5 2 Getting Started 6 2.1

More information

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

Product Overview. Product Identification. Amps One CT Two CTs Three CTs AH06 (optional mounting bracket for small, medium, and large CTs) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

Prodigy to Encore HD Manual Powder Spray System Upgrade Kit

Prodigy to Encore HD Manual Powder Spray System Upgrade Kit Instruction Sheet P/N 60780-0 Prodigy to Encore HD Manual Powder Spray System Upgrade Kit WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this

More information

MP8000 BLUETOOTH OVERLOAD RELAY FAQ

MP8000 BLUETOOTH OVERLOAD RELAY FAQ MP8000 BLUETOOTH OVERLOAD RELAY FAQ Patent Pending MP8000 SPECIFICATIONS What can I protect with the In what voltage range can the MP8000 operate? What amp range does the MP8000 have? Do I need external

More information

3000VA 120/208/230VAC

3000VA 120/208/230VAC User s Manual English Smart-UPS 2200VA 120/230VAC 3000VA 120/208/230VAC 2U Rack Mount Uninterruptible Power Supply 990-1352 12/02 Introduction The APC Uninterruptible Power Supply (UPS) is designed to

More information

MC-CRX. Bill Acceptor Card Reader Combo. Operation & Service Manual

MC-CRX. Bill Acceptor Card Reader Combo. Operation & Service Manual MC-CRX Bill Acceptor Card Reader Combo Operation & Service Manual TABLE OF CONTENTS SECTION 1: GENERAL INFORMATION Introduction...4 Features...4 For Records...4 After Unpacking...4 Naming Convention...5

More information

Discrete Output Modules IC697MDL753

Discrete Output Modules IC697MDL753 52 1 I97MDL753 (I97MDL753) datasheet Features 32 Points - Two isolated groups of 16 points each a44141 0.5 amp capacity per point High inrush capacity (10x rated current) Functions The 5/48 Volt DC 0.5

More information

A419ABG-3C Electronic Temperature Control

A419ABG-3C Electronic Temperature Control Installation Instructions Issue Date June 16, 2003 A419ABG-3C Electronic Temperature Control Application IMPORTANT: Use this A419ABG-3C Electronic Temperature Control only as an operating control. Where

More information

Hi-Z USB Wireless. Introduction/Welcome

Hi-Z USB Wireless. Introduction/Welcome Hi-Z USB Wireless Introduction/Welcome Thank you for selecting the Hi-Z Antennas USB Wireless system. The Hi-Z USB Wireless system provides control functions from a personal computer to operate a Hi-Z

More information

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor. sales@jumo.co.uk info.us@jumo.net Page 1/8 JUMO thermocor Portable measuring system for AMS2750 and CQI-9 Brief description The JUMO thermocor is a high-precision documenting test device with 12 analog

More information

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS CENTRALIZED Battery System BS-EN-50171 Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS 10KVA-40KVA The systems running

More information

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48. support@i2systems.com www.i2systems.com Electrical Specifications PARAMETER Input Power VALUE 8 Watts* / Ft Input Voltage 120-277V AC, 50/60 Hz Max. Fixture Run Length LED Color (CCT) 8 Watts: 120VAC:

More information

My Reserve 500 Install Guide

My Reserve 500 Install Guide My Reserve 500 Install Guide System Overview Diagram Warnings Disclaimer of Liability and Warranty: This guide does not replace the Owner s Guide and Installation Instructions supplied with the components.

More information

JUMO DSM software. PC software for management, configuration, and maintenance of digital sensors. Operating Manual T90Z001K000

JUMO DSM software. PC software for management, configuration, and maintenance of digital sensors. Operating Manual T90Z001K000 JUMO DSM software PC software for management, configuration, and maintenance of digital sensors Operating Manual 20359900T90Z001K000 V1.00/EN/00661398 Contents 1 Introduction...................................................

More information

Silvertel. 1. Features. 2. Description. IEEE802.3at compliant. Maximum 30 Watt Output Power. High efficiency DC/DC converter

Silvertel. 1. Features. 2. Description. IEEE802.3at compliant. Maximum 30 Watt Output Power. High efficiency DC/DC converter Silvertel V.0 May 2009. Features Pb IEEE802.3at compliant Maximum 30 Watt Output Power High efficiency DC/DC converter Wide adjustable output voltage range 500Vdc isolation (input to output) Input voltage

More information

AeroVironment Universal Solar Pump Controllers

AeroVironment Universal Solar Pump Controllers AeroVironment Universal Solar Pump Controllers (Installer s business information to be affixed here.) User Manual Models: USPC-2000 (AV Part Number 03747-001 Rev. D) USPC-5000 (AV Part Number 03747-002

More information

Dispense interface converter NA-8 (RS-485/RS-232 to non-addressable RS-422/RS-485/RS-232 and backwards)

Dispense interface converter NA-8 (RS-485/RS-232 to non-addressable RS-422/RS-485/RS-232 and backwards) Dispense interface converter NA-8 (RS-485/RS-232 to non-addressable RS-422/RS-485/RS-232 and backwards) TECHNICAL GUIDE Review date: 20 January, 2017 Revision number: 1.02 TECHNOTRADE LTD CONTENT REVISION

More information

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3 Atlantic Battery Systems 1065 Market Street Paterson, NJ 07513 Phone: (800) 875-0073 Fax: (973) 523-2344 sales@atbatsys.com www.atbatsys.com SOS1 SOS2 SOS SERIES Spares On Site Battery Cabinet Installation

More information

WEM-MX-333mV. Integrated Meter Installation Guidelines

WEM-MX-333mV. Integrated Meter Installation Guidelines WEM-MX-333mV Integrated Meter Installation Guidelines Energy Tracking, LLC Dated: February 8, 2013 By: Support Staff Table of Contents Enclosure Mounting... 2 High Voltage Wiring Type... 4 High Voltage

More information

RETAINS STEERING WHEEL CONTROLS, FACTORY SETTINGS AND MORE!

RETAINS STEERING WHEEL CONTROLS, FACTORY SETTINGS AND MORE! Owner's Guide CH3 & Kenwood radio RETAINS STEERING WHEEL CONTROLS, FACTORY SETTINGS AND MORE! PRODUCTS REQUIRED idatalink Maestro RR Radio Replacement Interface CH3 Installation Harness OPTIONAL ACCESSORIES

More information

CP600 Communication Protocols

CP600 Communication Protocols 3ADR023066N0202 F854p_a_CP600_Communication_Protocols_Rev_D, 07/2015 (3ADR023066N0202) CP600 Communication Protocols CP600 Control Panels Contents Communication Protocols ABB Controllers: Drivers List

More information

PDC PROPELLER DE-ICE CONTROLLER

PDC PROPELLER DE-ICE CONTROLLER PDC PROPELLER DE-ICE CONTROLLER OPERATIONAL & INSTALL MANUAL Updated: 14 October 2016 Copyright 2016 by VR Avionics Inc. All rights reserved. This User and Installation Guide and the information contained

More information

RETAINS STEERING WHEEL CONTROLS, FACTORY SETTINGS AND MORE!

RETAINS STEERING WHEEL CONTROLS, FACTORY SETTINGS AND MORE! Owner's Guide CH2 & Kenwood radio RETAINS STEERING WHEEL CONTROLS, FACTORY SETTINGS AND MORE! PRODUCTS REQUIRED idatalink Maestro RR Radio Replacement Interface CH2 Installation Harness OPTIONAL ACCESSORIES

More information

Dominion PX TM. Frequently Dominion PX TM Asked Frequently Asked Questions. General Questions

Dominion PX TM. Frequently Dominion PX TM Asked Frequently Asked Questions. General Questions Frequently Dominion PX TM Asked Frequently Asked s Dominion PX TM General s What is Dominion PX (PX)? Is Raritan new to the rack power distribution unit market? Can the PX be used as a stand-alone device?

More information

PSU EN54-4 Power Supplies

PSU EN54-4 Power Supplies PSU EN54-4 Power Supplies Ordering: Models, Sales Order Parts: PSU MXP-549 : 1.5A PSE in 7Ah enclosure MXP-550 : 3.0A PSE in 17/18Ah enclosure MXP-550D : 3.0A PSE in 25Ah enclosure MXP-551 : 5.0A PSE in

More information

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors Unidrive M600 High performance drive for induction and sensorless permanent magnet motors 0.75 kw - 2.8 MW Heavy Duty (1.0 hp - 4,200 hp) 200 V 400 V 575 V 690 V Unidrive M600 features Easy click-in keypad

More information

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8 Contents : 1. INTRODUCTION...1 2. IMPORTANT SAFETY INSTRUCTIONS...2 3. SYSTEM DESCRIPTION...4 3.1 Front Panel...4 4. CONNECTION AND OPERATION...6 5. TROUBLESHOOTING...8 6. MAINTENANCE...9 6.1 Operation...9

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary

More information

SP PRO KACO Managed AC Coupling

SP PRO KACO Managed AC Coupling SP PRO KACO Managed AC Coupling Introduction The SP PRO KACO Managed AC Coupling provides a method of linking the KACO Powador xx00 and Powador xx02 series grid tie inverters to the SP PRO via the AC Load

More information

Wall Mount Charging System. Owner s Manual. Simply Smart.

Wall Mount Charging System. Owner s Manual. Simply Smart. Wall Mount Charging System Owner s Manual Simply Smart. 2010-2011 by Electric Transportation Engineering Corporation. All rights reserved. No part of the contents of this document may be reproduced or

More information

Pulsar Evolution 1500 / 1500 Rack 1100 / 1100 Rack 800 / 800 Rack 500 Rack

Pulsar Evolution 1500 / 1500 Rack 1100 / 1100 Rack 800 / 800 Rack 500 Rack www.mgeups.com MGE UPS SYSTEMS Pulsar Evolution 1500 / 1500 Rack 1100 / 1100 Rack 800 / 800 Rack 500 Rack Installation and user manual S T O P Y O U N O W L L W I N G I T H N O 34007117EN/AB - Page 1 Page

More information

AC Level 2 Commercial Charging System. Owner s Manual. Simply Smart.

AC Level 2 Commercial Charging System. Owner s Manual. Simply Smart. AC Level 2 Commercial Charging System Owner s Manual Simply Smart. 2014 by Blink Network, LLC. All rights reserved. No part of the contents of this document may be reproduced or transmitted in any form

More information

AC Level 2 Commercial Charging System. Owner s Manual. Simply Smart.

AC Level 2 Commercial Charging System. Owner s Manual. Simply Smart. AC Level 2 Commercial Charging System Owner s Manual Simply Smart. 2014 by Blink Network, LLC. All rights reserved. No part of the contents of this document may be reproduced or transmitted in any form

More information

QUICK REFERENCE MANUAL

QUICK REFERENCE MANUAL ORPAK Tag Reader (OrTR) QUICK REFERENCE MANUAL 1.1. OrTR Available Configurations Available configurations MiFare Reader KB (language) Magnetic card reader RS485 LAN RS232 OrTR KB(xx, xx, xxx) OrTR(xx,

More information

IEDA524-H / IEDA520DTB DIGITAL MICROPHONE STATION. Installation Instructions

IEDA524-H / IEDA520DTB DIGITAL MICROPHONE STATION. Installation Instructions IEDA524-H / IED0520DTB DIGITAL MICROPHONE STATION Installation Instructions REV: 12-12 DOC: 369B INSTALLATION INSTRUCTIONS INTRODUCTION Description The IED 524 digital microphone station is a 4-button

More information

V-D2425 and V-D2440 Digital Clock

V-D2425 and V-D2440 Digital Clock Installation Manual V1.03 V-D2425 and V-D2440 Digital Clock Valcom, Inc. V-D2425 and V-D2440 Wired Clock Table of Contents Table Installation of Contents 2 Instructions Flush Mount Installation 3 3 Wall

More information

SCP Hardware Quick Reference

SCP Hardware Quick Reference SP Hardware Quick Reference RS Technologies, LL - 00 Fisher Street, Suite G - Munster, IN 6 - (877) 68- - Fax (9) 86-90 www.rstech.com Revised: /08 Table Of ontents MODEL PAGE MODEL PAGE MINI-SP MINI-SPE

More information

SMART TICKET INTEGRATION GUIDE

SMART TICKET INTEGRATION GUIDE SMART TICKET INTEGRATION GUIDE SMART Ticket Integration Guide MANUAL AMENDMENTS Rev. Date Amendment Details Issued by 18-01-13 First Issue AB SMART Ticket Integration Guide SMART TICKET MANUAL - INTRODUCTION

More information

USER GUIDE 1 USER GUIDE

USER GUIDE 1 USER GUIDE USER GUIDE 1 USER GUIDE 1 TABLE OF CONTENTS IN THE BOX...3 NAVIGATING THE MENUS...3 MENU LAYOUT...3 UPDATE YOUR PROGRAMMER...4 CONNECT WITH THE MOTORCYCLE...5 TUNE YOUR MOTORCYCLE...6 ADDITIONAL FEATURES...8

More information

Elite Power Solutions Automatic Battery Control (ABC) Operation Manual

Elite Power Solutions Automatic Battery Control (ABC) Operation Manual Elite Power Solutions Automatic Battery Control (ABC) Operation Manual Elite Power Solutions 335 E Warner Rd. STE 3 Chandler, AZ 85225 www.elitepowersolutions.com ABC Operation Manual Page 1 Table of Contents

More information

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications DIN-Rail DC UPS Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications Combines all system power functions: power supply, battery charger, UPS circuitry

More information

LU23, LU28 & LU29 Series Quick Start

LU23, LU28 & LU29 Series Quick Start Ultrasonic Liquid Level Transmitter LU23, LU28 & LU29 Series Quick Start 2016 Flowline, Inc. All Rights Reserved Made in USA Flowline, Inc. 10500 Humbolt Street, Los Alamitos, CA 90720 p 562.598.3015 f

More information

EIP APPLICABILITY & EFFECTIVITY

EIP APPLICABILITY & EFFECTIVITY ProtoCessor ProtoNode RER Startup Guide For Interfacing Toshiba Products: G8000 & G9000 To Building Automation Systems: Modbus/RTU, Modbus/TCP, BACnet MS/TP, BACnet/IP, Metasys N2, SNMP and AB EIP APPLICABILITY

More information

QuickServer Start-up Guide

QuickServer Start-up Guide QuickServer Start-up Guide FS-QS-1010/1011/12X0/12X1 APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after August 2013 Kernel Version: 6.10 Document Revision: 1 QuickServer Start-up

More information

RF80-M. Features. Lead Acid Batteries Multistep Programmable. Automatic Operation Stores 100 Programs

RF80-M. Features. Lead Acid Batteries Multistep Programmable. Automatic Operation Stores 100 Programs RF80-M CHRISTIE Aircraft Battery Charger / Analyzer Features Nickel Cadmium Batteries Lead Acid Batteries Multistep Programmable Automatic Operation Stores 100 Programs Unique ReFLEX Charging Exclusive

More information

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY Issue 6 VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY INTRODUCTION These instructions provide the specifications, installation and maintenance information for the VP-6124 and VP-6124-E, 24Volt Power

More information

ESI[tronic] 2.0 Trainer

ESI[tronic] 2.0 Trainer Service Training Center Robert Bosch GmbH Automotive Aftermarket Diagnostics www.bosch-diagnostics.de ESI[tronic] User training Course documentation Name :... Date : from... to... Location :... This training

More information

PowerCommand 500/550 Remote Monitoring System

PowerCommand 500/550 Remote Monitoring System PowerCommand 500/550 Remote Monitoring System Complete remote monitoring of your power system The PowerCommand 500 series provides a convenient means of remotely monitoring generator sets, transfer switches,

More information

Overview of operation modes

Overview of operation modes Overview of operation modes There are three main operation modes available. Any of the modes can be selected at any time. The three main modes are: manual, automatic and mappable modes 1 to 4. The MapDCCD

More information

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W Page 1 / 7 Full operation without need of battery Two independent 48Vdc outputs for switching and control Local monitoring with 8 LEDs Remote monitoring with 4 alarm relays Monitoring and configuration

More information

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Dycon D2430 EN54-4 Fire Alarm Power Supply Series Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product

More information

SAX Electronic Valve Actuator

SAX Electronic Valve Actuator SAX Electronic Valve Actuator Non-spring Return, 24 Vac, Proportional Control Technical Instructions Document No. 155-506 Description The SAX Non-spring Return (NSR), Electronic Valve Actuator requires

More information